WorldWideScience

Sample records for dynamic adc testing

  1. An ADC test system based on the Macintosh computer

    International Nuclear Information System (INIS)

    Gao, Z.; Spiriti, E.; Tortora, L.

    1994-01-01

    DAΦNE is an approved INFN Φ-factory project to be realized at the Frascati National Laboratories of Italy. DAΦNE consists of the construction of a two-ring colliding beam Φ Factory and a 510 Mev e + /e - injector for topping-up. KLOE is a general purpose detector to be used at DAΦNE which is optimized for the study of CP violation in K 0 decays with the aim of achieving a statistical accuracy of ∼ 10 -4 for R(var-epsilon '/var-epsilon) in a one year run at the DAΦNE target luminosity of 10 33 cm -2 S -1 . In the electromagnetic calorimeter front end electronics readout system, the ADC modules are used to provide energy deposit information. A prototype 12 bit/1us ADC CAMAC module has been developed and tested by a system based on the Macintosh computer. Characteristics and performance of the system are described

  2. Development of COTS ADC SEE Test System for the ATLAS LAr Calorimeter Upgrade

    CERN Document Server

    INSPIRE-00338739; Chen, Hucheng; Chen, Kai; Mead, Joseph; Liu, Shubin; An, Qi

    2014-01-01

    Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evalu...

  3. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  4. A high speed low power low offset dynamic comparator used in SHA-less pipelined ADC

    Science.gov (United States)

    Shubin, Liu; Zhangming, Zhu; Yintang, Yang; Lianxi, Liu

    2014-05-01

    A novel fully differential high speed high resolution low offset CMOS dynamic comparator has been implemented in the SMIC 0.18 μm process used for a sample-and-hold amplifier (SHA)-less pipelined analog-to-digital converters (ADC). Based on the analysis and optimization between delay time and offset, an enhanced reset architecture with transmission gate was introduced to speed up the comparison and reset procedure. Four inputs with two cross coupled differential pairs, reconstituted bias circuit for tail current transistor and common centroid layouts make the comparator more robust against mismatch and process variations. The simulation results demonstrate that the proposed design achieves 1 mV sensitivity at 2.2 GHz sampling rate with a power consumption of 510 μW, while the mean offset voltage is equal to 10.244 mV.

  5. Glioma grading capability: Comparisons among parameters from dynamic contrast-enhanced MRI and ADC value on DWI

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyun Seok; Kim, Ah Hyun; Ahn, Sung Soo; Shin, Na Young; Kim, Jin Na; Lee, Seung Koo [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul , (Korea, Republic of)

    2013-06-15

    Permeability parameters from dynamic contrast-enhanced MRI (DCE-MRI) and apparent diffusion coefficient (ADC) value on diffusion-weighted imaging (DWI) can be quantitative physiologic metrics for gliomas. The transfer constant (K{sup trans}) has shown efficacy in grading gliomas. Volume fraction of extravascular extracellular space (v{sub e}) has been underutilized to grade gliomas. The purpose of this study was to evaluate v{sub e} in its ability to grade gliomas and to assess the correlation with other permeability parameters and ADC values. A total of 33 patients diagnosed with pathologically-confirmed gliomas were examined by 3 T MRI including DCE-MRI and ADC map. A region of interest analyses for permeability parameters from DCE-MRI and ADC were performed on the enhancing solid portion of the tumors. Permeability parameters form DCE-MRI and ADC between low- and high-grade gliomas; the diagnostic performances of presumptive metrics and correlation among those metrics were statistically analyzed. High-grade gliomas showed higher K{sup trans} (0.050 vs. 0.010 in median value, p = 0.002) and higher v{sub e} (0.170 vs. 0.015 in median value, p = 0.001) than low-grade gliomas. Receiver operating characteristic curve analysis showed significance in both K{sup trans} and v{sub e} for glioma grading. However, there was no significant difference in diagnostic performance between K{sup trans} and v{sub e}. ADC value did not correlate with any of the permeability parameters from DCE-MRI. Extravascular extracellular space (v{sub e}) appears to be comparable with transfer constant (K{sup trans}) in differentiating high-grade gliomas from low-grade gliomas. ADC value does not show correlation with any permeability parameters from DCE-MRI.

  6. A 9-Bit 50 MSPS Quadrature Parallel Pipeline ADC for Communication Receiver Application

    Science.gov (United States)

    Roy, Sounak; Banerjee, Swapna

    2018-03-01

    This paper presents the design and implementation of a pipeline Analog-to-Digital Converter (ADC) for superheterodyne receiver application. Several enhancement techniques have been applied in implementing the ADC, in order to relax the target specifications of its building blocks. The concepts of time interleaving and double sampling have been used simultaneously to enhance the sampling speed and to reduce the number of amplifiers used in the ADC. Removal of a front end sample-and-hold amplifier is possible by employing dynamic comparators with switched capacitor based comparison of input signal and reference voltage. Each module of the ADC comprises two 2.5-bit stages followed by two 1.5-bit stages and a 3-bit flash stage. Four such pipeline ADC modules are time interleaved using two pairs of non-overlapping clock signals. These two pairs of clock signals are in phase quadrature with each other. Hence the term quadrature parallel pipeline ADC has been used. These configurations ensure that the entire ADC contains only eight operational-trans-conductance amplifiers. The ADC is implemented in a 0.18-μm CMOS process and supply voltage of 1.8 V. The proto-type is tested at sampling frequencies of 50 and 75 MSPS producing an Effective Number of Bits (ENOB) of 6.86- and 6.11-bits respectively. At peak sampling speed, the core ADC consumes only 65 mW of power.

  7. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  8. Integrated tests of a high speed VXS switch card and 250 MSPS flash ADCs

    International Nuclear Information System (INIS)

    Dong, H.; Cuevas, C.; Curry, D.; Jastrzembski, E.; Barbosa, F.; Wilson, J.; Taylor, M.; Raydo, B.

    2008-01-01

    High trigger rate nuclear physics experiments proposed for the 12 GeV upgrade at the Thomas Jefferson National Accelerator Facility create a need for new high speed digital systems for energy summing. Signals from electronic detectors will be captured with the Jefferson Lab FADC module, which collects and processes data from 16 charged particle sensors with 10 or 12 bit resolution at 250 MHz sample rate. Up to sixteen FADC modules transfer energy information to a central energy summing module for each readout crate. The sums from the crates are combined to form a global energy sum that is used to trigger data readout for all modules. The Energy Sum module and FADC modules have been designed using the VITA-41 VME64 switched serial (VXS) standard. The VITA- 41 standard defines payload and switch slot module functions, and offers an elegant engineered solution for Multi-Gigabit serial transmission on a standard VITA-41 backplane. The Jefferson Lab Energy Sum module receives data serially at a rate of up to 6 Giga-bits per second from the FADC modules. Both FADC and Energy Sum modules have been designed and assembled and this paper describes the integrated tests using both high speed modules in unison

  9. A low-power 10 bit ADC in a 0.25$\\mu$m CMOS design considerations and test results

    CERN Document Server

    Rivetti, A; Anghinolfi, Francis; Mazza, G; Rotondo, F

    2000-01-01

    This paper presents the design and test of a low power analog to digital converter implemented in a commercial 0.25 mu m CMOS technology. The circuit has been developed to serve as a building block in multi-channel data acquisition systems for high energy physics (HEP) applications. Therefore medium resolution (10 bits), very low power consumption and high modularity are the key features of the design. In HEP experiments the resistance of the electronics to the ionizing radiation is often a primary issue. Hence the ADC has been laid-out using a radiation tolerant approach. The test results show that the chip operates as a full 10 bit converter up to a clock frequency of 30 MHz. No degradation in performance has been measured after a total dose of 10 Mrd (SiO/sub 2/). (7 refs).

  10. Brookhaven FASTBUS ADC's

    International Nuclear Information System (INIS)

    Schmidt, M.P.; Black, J.K.; Blatt, S.R.

    1983-01-01

    A high energy physics experiment has been performed at Brookhaven National Laboratory on k/sub L/ 0 → 2π 0 decays employing a large (> 200 element) lead glass array as an electromagnetic calorimeter. To acquire pulse height information from the detector we have constructed ADC modules in the context of the Brookhaven Fastbus data acquisition system. Digitization (8 bits) and encoding, including pedestal subtraction and data sparsing, is achieved for each 16 channel module in 6 μsec

  11. Flash-ADCs test, optimization of the detector design and development of a new concept of spatial reconstruction in the double chooz neutrino oscillation experiment

    International Nuclear Information System (INIS)

    Akiri, T.

    2010-09-01

    Double Chooz (DC) is a reactor neutrino oscillation experiment whose purpose is the measurement of the last unknown mixing angle θ 13 . It inherits from the past Chooz experiment which was limited by the statistical and systematic errors at the same extent of about 2.8%. To lower the statistical error, the DC detector target mass has been increased and a longer exposure is foreseen while the lowering of the systematic error is ensured by the use of two identical detectors. One will be located in the vicinity of the reactor cores to monitor the flux and spectrum of the ν-bar e emitted whereas the other one will be located where the effect of the oscillation is expected to be maximal. They are respectively so-called 'near' and 'far' detectors. The expected errors are 0.5% (stat.) and 0.6% (syst.) for a measurement down to sin 2 (2*θ 13 ) = 0.05 (θ 13 6.5 degrees) at three standard deviations after three years of data taking. The far detector is expected for November 2010 while the near detector will be operational in mid-2012. This thesis presents first a hardware work consisting in testing the Flash-ADCs that are the core of the main acquisition system of the experiment. Subsequently, it presents analyses performed on Monte Carlo simulations towards the optimization of the detector design. This work was composed of analyses to choose some detector components with the appropriate natural radioactivity contamination, analyses for the best achievable energy resolution and the most stable and robust way of triggering. The work on the optimization of the detector together with the acquired knowledge on the Flash-ADCs led us to envisage the possibility of a new spatial reconstruction based on the time of flight. All these contributions to the experiment are described in details throughout this manuscript. (author)

  12. A fast, low-power, 6-bit SAR ADC for readout of strip detectors in the LHCb Upgrade experiment.

    CERN Document Server

    Firlej, M; Idzik, M; Moron, J; Swientek, K

    2014-01-01

    The readout of silicon strip sensors in the upgraded Tracker System of Large Hadron Collider beauty (LHCb) experiment will require a novel complex Application Specific Integrated Circuit (ASIC). The ASIC will extract and digitise analogue signal from the sensor and subsequently will perform digital processing and serial data transmission. One of the key processing blocks, placed in each channel, will be an Analogue to Digital Converter (ADC). A prototype of fast, low-power 6-bit Successive Approximation Register (SAR) ADC was designed, fabricated and tested. The measurements of ADC prototypes confirmed simulation results showing excellent overall performance. In particular, very good resolution with Effective Number Of Bits (ENOB) 5.85 was obtained together with very low power consumption of 0.35 mW at 40 MS/s sampling rate. The results of the performed static and dynamic measurements confirm excellent ADC operation for higher sampling rates up to 80 MS/s.

  13. A fast, low-power, 6-bit SAR ADC for readout of strip detectors in the LHCb Upgrade experiment

    Science.gov (United States)

    Firlej, M.; Fiutowski, T.; Idzik, M.; Moron, J.; Swientek, K.

    2014-07-01

    The readout of silicon strip sensors in the upgraded Tracker System of Large Hadron Collider beauty (LHCb) experiment will require a novel complex Application Specific Integrated Circuit (ASIC). The ASIC will extract and digitise analogue signal from the sensor and subsequently will perform digital processing and serial data transmission. One of the key processing blocks, placed in each channel, will be an Analogue to Digital Converter (ADC). A prototype of fast, low-power 6-bit Successive Approximation Register (SAR) ADC was designed, fabricated and tested. The measurements of ADC prototypes confirmed simulation results showing excellent overall performance. In particular, very good resolution with Effective Number Of Bits (ENOB) 5.85 was obtained together with very low power consumption of 0.35 mW at 40 MS/s sampling rate. The results of the performed static and dynamic measurements confirm excellent ADC operation for higher sampling rates up to 80 MS/s.

  14. Self-adapted sliding scale spectroscopy ADC

    International Nuclear Information System (INIS)

    Xu Qichun; Wang Jingjin

    1992-01-01

    The traditional sliding scale technique causes a disabled range that is equal to the sliding length, thus reduces the analysis range of a MCA. A method for reduce ADC's DNL, which is called self-adapted sliding scale method, has been designed and tested. With this method, the disabled range caused by a traditional sliding scale method can be eliminated by a random trial scale and there is no need of an additional amplitude discriminator with swing threshold. A special trial-and-correct logic is presented. The tested DNL of the spectroscopy ADC described here is less than 0.5%

  15. A 1.2-V 165-μW 0.29-mm2 multibit Sigma-Delta ADC for hearing aids using nonlinear DACs and with over 91 dB dynamic-range.

    Science.gov (United States)

    Custodio, José R; Goes, João; Paulino, Nuno; Oliveira, João P; Bruun, Erik

    2013-06-01

    This paper describes the design and experimental evaluation of a multibit Sigma-Delta (ΣΔ) modulator (ΣΔM) with enhanced dynamic range (DR) through the use of nonlinear digital-to-analog converters (DACs) in the feedback paths. This nonlinearity imposes a trade-off between DR and distortion, which is well suited to the intended hearing aid application. The modulator proposed here uses a fully-differential self-biased amplifier and a 4-bit quantizer based on fully dynamic comparators employing MOS parametric pre-amplification to improve both energy and area efficiencies. A test chip was fabricated in a 130 nm digital CMOS technology, which includes the proposed modulator with nonlinear DACs and a modulator with conventional linear DACs, for comparison purposes. The measured results show that the ΣΔM using nonlinear DACs achieves an enhancement of the DR around 8.4 dB (to 91.4 dB). Power dissipation and silicon area are about the same for the two cases. The performance achieved is comparable to that of the best reported multibit ΣΔ ADCs, with the advantage of occupying less silicon area (7.5 times lower area when compared with the most energy efficient ΣΔM).

  16. ADC Catalog Services: an Update

    Science.gov (United States)

    Gass, J. E.; Roman, N. G.; Schneider, G. L.; Blackwell, J. H.; Kuin, N. P. M.; Larkin, M. C.; Lyu, C.-C. J.; Cheung, C. Y.

    1996-12-01

    The Astronomical Data Center (ADC) at the NASA Goddard Space Flight Center is a major archive and distribution center for computer-readable versions of astronomical catalogs and journal data tables. The ADC's archives contain more than 1600 catalogs and tables of astrometry, photometry, spectroscopy, radio, high energy, and other miscellaneous data for stellar and non-stellar objects. These data files are documented in a standardized manner, developed in cooperation with the Centre de Donnees astronomiques de Strasbourg (CDS). The ADC's data collection is available via anonymous FTP from node adc.gsfc.nasa.gov in the /pub/adc/archives directory. The holdings can also be accessed from the ADC's WWW site, http://adc.gsfc.nasa.gov/. This site permits users to search the text of the documentation files to locate catalogs and tables of interest or to browse the archives. Hypertext author and keyword indices, and other browsing tools have recently been developed as additional aids to navigating the ADC's large collection of data sets. The ADC is currently developing services to allow researchers to easily locate data fields of interest within files in its archives. The ADC has also prepared three volumes of CD-ROMs that contain several hundred of the largest and most requested catalogs in both ASCII and FITS table formats.

  17. High-resolution IF-to-baseband sigma delta ADC for car radios

    CERN Document Server

    Silva, Paulo G R

    2008-01-01

    High-Resolution IF-to-Baseband SigmaDelta ADC for Car Radios addresses the theory, system level design and circuit implementation of a high-resolution continuous-time IF-to-baseband quadrature SigmaDelta ADC. The target application of this ADC is in AM/FM/IBOC car radios. The ADC achieves a dynamic range of 118dB, which eliminates the need for an IF VGA or AM channel filter in car radios.

  18. Radiation effect test on ADC/DAC and high density memory devices with 60Co γ-rays

    International Nuclear Information System (INIS)

    Xing Kefei; Wang Yueke; Pan Huafeng

    2006-01-01

    A test platform was constructed for 60 Co γ-ray irradiation experiment of microelectronics, with the aid of computer and a FPGA module. The tested sample devices included analog-to-digital converter AD10465, digital-to-analog converter AD9857, high density Flash memory MEF64M16 and anti-fused PROM XQR17V16, which are used in signal processing module in spaceborne systems. Evaluations were made on their ability of resisting the total dose based on the proper function criterion of the devices. The results showed that AD10465 and AD9857 ran properly after 1.59 kGy(Si) irradiation, but errors were found when MEF64M16 and XQR17V16's total ionizing dose is 0.13 kGy(Si) and 0.99 kGy(Si), respectively. (authors)

  19. High performance 14-bit pipelined redundant signed digit ADC

    Science.gov (United States)

    Narula, Swina; Pandey, Sujata

    2016-03-01

    A novel architecture of a pipelined redundant-signed-digit analog to digital converter (RSD-ADC) is presented featuring a high signal to noise ratio (SNR), spurious free dynamic range (SFDR) and signal to noise plus distortion (SNDR) with efficient background correction logic. The proposed ADC architecture shows high accuracy with a high speed circuit and efficient utilization of the hardware. This paper demonstrates the functionality of the digital correction logic of 14-bit pipelined ADC at each 1.5 bit/stage. This prototype of ADC architecture accounts for capacitor mismatch, comparator offset and finite Op-Amp gain error in the MDAC (residue amplification circuit) stages. With the proposed architecture of ADC, SNDR obtained is 85.89 dB, SNR is 85.9 dB and SFDR obtained is 102.8 dB at the sample rate of 100 MHz. This novel architecture of digital correction logic is transparent to the overall system, which is demonstrated by using 14-bit pipelined ADC. After a latency of 14 clocks, digital output will be available at every clock pulse. To describe the circuit behavior of the ADC, VHDL and MATLAB programs are used. The proposed architecture is also capable of reducing the digital hardware. Silicon area is also the complexity of the design.

  20. High performance 14-bit pipelined redundant signed digit ADC

    International Nuclear Information System (INIS)

    Narula, Swina; Pandey, Sujata

    2016-01-01

    A novel architecture of a pipelined redundant-signed-digit analog to digital converter (RSD-ADC) is presented featuring a high signal to noise ratio (SNR), spurious free dynamic range (SFDR) and signal to noise plus distortion (SNDR) with efficient background correction logic. The proposed ADC architecture shows high accuracy with a high speed circuit and efficient utilization of the hardware. This paper demonstrates the functionality of the digital correction logic of 14-bit pipelined ADC at each 1.5 bit/stage. This prototype of ADC architecture accounts for capacitor mismatch, comparator offset and finite Op-Amp gain error in the MDAC (residue amplification circuit) stages. With the proposed architecture of ADC, SNDR obtained is 85.89 dB, SNR is 85.9 dB and SFDR obtained is 102.8 dB at the sample rate of 100 MHz. This novel architecture of digital correction logic is transparent to the overall system, which is demonstrated by using 14-bit pipelined ADC. After a latency of 14 clocks, digital output will be available at every clock pulse. To describe the circuit behavior of the ADC, VHDL and MATLAB programs are used. The proposed architecture is also capable of reducing the digital hardware. Silicon area is also the complexity of the design. (paper)

  1. Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different Postprocessing Software: Reproducibility in Endometrial Carcinoma.

    Science.gov (United States)

    Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan

    2017-12-01

    Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.

  2. A custom floating point format ADC for LHC calorimetry

    International Nuclear Information System (INIS)

    Hermel, V.; Lecoq, J.; Bohner, G.

    1996-01-01

    Due to their large dynamic range (in excess of 16 bits) signals from LHC calorimetry poses severe problems to the shaping and digitizing circuits. We are investigating a solution for an ADC based on a custom floating point format. Since the calorimeter precision is limited, the full dynamic range can be split into 8 positive sub-ranges and 5 negative ones, each with an 8 bits dynamic. The reduced number of bits (8 for the mantissa, 4 for the exponent and 1 for the sign) translates itself into a reduction of the power consumption both of the ADC and of the following digital filtering stages. (authors)

  3. Technology of pile dynamic testing

    OpenAIRE

    Holeyman, Alain; The 4th International Conference on the Application of Stress-Wave Theory to Piles

    1992-01-01

    Because of the recent larger availability and higher performance of pile testing and monitoring equipment, pile dynamic testing has become part of many present day civil engineering projects. This report covers the past and state-of-the-art technological aspects of pile dynamic testing: testing methods, loading equipment, and measurements, including their acquisition and interpretation. Three major pile dynamic testing methods are distinguished based on means and objectives: high-strain testi...

  4. Development of an ADC radiation tolerance characterization system for the upgrade of the ATLAS LAr calorimeter

    Science.gov (United States)

    Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge

    2017-02-01

    ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. To evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well. Supported by the U. S. Department of Energy (DE-SC001270)

  5. Dynamic Tracker Test Apparatus

    Science.gov (United States)

    2006-03-01

    failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE...rotates about one of these other axis. It is further noted that, even though the dynamic forcing function is not accurately controlled , the measurements... Plaga , Mr. Brian J. Grattan, and Mr. Bob J. Flannery for responding to our request concerning head movement data and acting as subjects. 10

  6. Application of DWIBS in malignant lymphoma: correlation between ADC values and Ki-67 index.

    Science.gov (United States)

    Sun, Mengtian; Cheng, Jingliang; Zhang, Yong; Bai, Jie; Wang, Feifei; Meng, Yun; Li, Zhenqian

    2018-04-01

    We investigated the correlation between the apparent diffusion coefficient (ADC) and Ki-67 index using diffusion-weighted whole-body imaging with background body signal suppression (DWIBS), and their utility in evaluating malignant lymphoma cell proliferation. Seventy-four patients with malignant lymphoma underwent DWIBS within 1 week before pathological confirmation. The ADC value was measured at the site of the pathological examination, and specimens were also stained with Ki-67. The ADC values and Ki-67 indices in aggressive non-Hodgkin's lymphoma (NHL), indolent NHL, and Hodgkin's lymphoma (HL) were compared using Spearman's rank correlation coefficient and the Kruskal-Wallis test. The Ki-67 indices and ADC values were inversely correlated (r = -0.289, p = 0.0125); the differences in the Ki-67 index between aggressive NHL, indolent NHL, and HL were significant (p values were significantly different between the types of lymphoma (p = 0.013); the Nemenyi test showed a significant difference only between aggressive NHL and HL. The Ki-67 indices and ADC values are inversely correlated in patients with lymphoma, combining DWIBS and ADC values can evaluate the proliferation level of malignant lymphoma cells noninvasively. • By using DWIBS, malignant lymphoma cell proliferation can be assessed noninvasively. • The ADC value and Ki-67 index are significantly and inversely correlated. • The ADC values were lower in aggressive NHL than in HL. • The ADC values of aggressive and indolent NHL were not significantly different.

  7. A 10MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65m CMOS

    CERN Document Server

    Kishishita, T; Krüger, H; Koch, M; Germic, L; Wermes, N

    2013-01-01

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a highspeed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40 μm 70 μm for one ADC channel. The power consumption is estimated as 4 μW at 1 MS/s and 38 μW at 10 MS/s with a supply rail of 1.2 V. Th...

  8. Dynamic testing of cable structures

    Directory of Open Access Journals (Sweden)

    Caetano Elsa

    2015-01-01

    Full Text Available The paper discusses the role of dynamic testing in the study of cable structures. In this context, the identification of cable force based on vibration measurements is discussed. Vibration and damping assessment are then introduced as the focus of dynamic monitoring systems, and particular aspects of the structural behaviour under environmental loads are analysed. Diverse application results are presented to support the discussion centred on cable-stayed bridges, roof structures, a guyed mast and a transmission line.

  9. Diagnostic value of diffusion weighted MRI and ADC in differential ...

    African Journals Online (AJOL)

    After DWI examination, an ADC map was created and ADC values were measured for 72 liver masses and normal liver tissue (control group). The average ADC values of normal liver tissue and focal liver lesions, the “cut-off ” ADC values, and the diagnostic sensitivity and specificity of the ADC map in diagnosing ...

  10. Dynamic impact testing with servohydraulic testing machines

    Science.gov (United States)

    Bardenheier, R.; Rogers, G.

    2006-08-01

    The design concept of “Crashworthiness” requires the information on material behaviour under dynamic impact loading in order to describe and predict the crash behaviour of structures. Especially the transport related industries, like car, railway or aircraft industry, pursue the concept of lightweight design for a while now. The materials' maximum constraint during loading is pushed to permanently increasing figures. This means in terms of crashworthiness that the process of energy absorption in structures and the mechanical behaviour of materials must well understood and can be described appropriately by material models. In close cooperation with experts from various industries and research institutes Instron has developed throughout the past years a new family of servohydraulic testing machines specifically designed to cope with the dynamics of high rate testing. Main development steps are reflected versus their experimental necessities.

  11. Design and implementation of a platform for experimental testing and validation of analog-to-digital converters: static and dynamic parameters

    Directory of Open Access Journals (Sweden)

    Mansour Imen Ben

    2017-01-01

    Full Text Available This paper presents an implementation of a data acquisition system for analog-to-digital converters (ADCs using “Laboratory Virtual Instrument Engineering Workbench (LabVIEW” as software for data analysis. The designed and implemented platform allows interaction with the device under test through means of data acquisition and instrument controls. Developing custom tests in LabVIEW can result in reduced test time, which in turn will help reduce costs in testing. This system was developed for evaluation purposes of ADC's static and dynamic parameters (gain error, offset error, DNL, INL, SNR, SINAD, IMD, etc. using single and multi-frequency signals. The virtual control and analysis instrument was created in “LabVIEW” environment to control test signals generation and data acquisition. The testing performance of the platform is demonstrated using the classical ADC circuit “ADC0804”. A comparison with experimental results obtained by CANTEST platform from Bordeaux University (France is also presented to highlight our platform.

  12. High power-efficient asynchronous SAR ADC for IoT devices

    Science.gov (United States)

    Zhang, Beichen; Yao, Bingbing; Liu, Liyuan; Liu, Jian; Wu, Nanjian

    2017-10-01

    This paper presents a power-efficient 100-MS/s, 10-bit asynchronous successive approximation register (SAR) ADC. It includes an on-chip reference buffer and the total power dissipation is 6.8 mW. To achieve high performance with high power-efficiency in the proposed ADC, bootstrapped switch, redundancy, set-and-down switching approach, dynamic comparator and dynamic logic techniques are employed. The prototype was fabricated using 65 nm standard CMOS technology. At a 1.2-V supply and 100 MS/s, the ADC achieves an SNDR of 56.2 dB and a SFDR of 65.1 dB. The ADC core consumes only 3.1 mW, resulting in a figure of merit (FOM) of 30.27 fJ/conversionstep and occupies an active area of only 0.009 mm2.

  13. PI-RADS v2 and ADC values: is there room for improvement?

    Science.gov (United States)

    Jordan, Eric J; Fiske, Charles; Zagoria, Ronald; Westphalen, Antonio C

    2018-03-17

    To determine the diagnostic accuracy of ADC values in combination with PI-RADS v2 for the diagnosis of clinically significant prostate cancer (CS-PCa) compared to PI-RADS v2 alone. This retrospective study included 155 men whom underwent 3-Tesla prostate MRI and subsequent MR/US fusion biopsies at a single non-academic center from 11/2014 to 3/2016. All scans were performed with a surface coil and included T2, diffusion-weighted, and dynamic contrast-enhanced sequences. Suspicious findings were classified using Prostate Imaging Reporting and Data System (PI-RADS) v2 and targeted using MR/US fusion biopsies. Mixed-effect logistic regression analyses were used to determine the ability of PIRADS v2 alone and combined with ADC values to predict CS-PCa. As ADC categories are more practical in clinical situations than numeric values, an additional model with ADC categories of ≤ 800 and > 800 was performed. A total of 243 suspicious lesions were included, 69 of which were CS-PCa, 34 were Gleason score 3+3 PCa, and 140 were negative. The overall PIRADS v2 score, ADC values, and ADC categories are independent statistically significant predictors of CS-PCa (p values or categories is better discrimination of PI-RADS v2 4 lesions. ADC values and categories help to diagnose CS-PCa when lesions are assigned a PI-RADS v2 score of 4.

  14. Incremental Prognostic Value of ADC Histogram Analysis over MGMT Promoter Methylation Status in Patients with Glioblastoma.

    Science.gov (United States)

    Choi, Yoon Seong; Ahn, Sung Soo; Kim, Dong Wook; Chang, Jong Hee; Kang, Seok-Gu; Kim, Eui Hyun; Kim, Se Hoon; Rim, Tyler Hyungtaek; Lee, Seung-Koo

    2016-10-01

    Purpose To investigate the incremental prognostic value of apparent diffusion coefficient (ADC) histogram analysis over oxygen 6-methylguanine-DNA methyltransferase (MGMT) promoter methylation status in patients with glioblastoma and the correlation between ADC parameters and MGMT status. Materials and Methods This retrospective study was approved by institutional review board, and informed consent was waived. A total of 112 patients with glioblastoma were divided into training (74 patients) and test (38 patients) sets. Overall survival (OS) and progression-free survival (PFS) was analyzed with ADC parameters, MGMT status, and other clinical factors. Multivariate Cox regression models with and without ADC parameters were constructed. Model performance was assessed with c index and receiver operating characteristic curve analyses for 12- and 16-month OS and 12-month PFS in the training set and validated in the test set. ADC parameters were compared according to MGMT status for the entire cohort. Results By using ADC parameters, the c indices and diagnostic accuracies for 12- and 16-month OS and 12-month PFS in the models showed significant improvement, with the exception of c indices in the models for PFS (P MGMT status. Conclusion ADC histogram analysis had incremental prognostic value over MGMT promoter methylation status in patients with glioblastoma. (©) RSNA, 2016 Online supplemental material is available for this article.

  15. Reliability of SAR ADCs and associated embedded instrument detection

    NARCIS (Netherlands)

    Wan, J.; Kerkhoff, Hans G.

    2015-01-01

    Successive-approximation-register (SAR) analog-to-digital converters (ADCs) represent the majority of the ADC market from medium to high resolution ADCs. Due to its low power, high-performance and small area in Mega-Hz range, SAR ADCs are increasingly attractive for todays safe-critical applications

  16. A 10-bit 120-MS/s pipelined ADC with improved switch and layout scaling strategy

    International Nuclear Information System (INIS)

    Zhou Jia; Xu Lili; Li Fule; Wang Zhihua

    2015-01-01

    A 10 bit, 120 MS/s two-channel pipelined analog-to digital converter (ADC) is presented. The ADC is featured with improved switch by using the body effect to improve its conduction performance. A scaling down strategy is proposed to get more efficiency in the OTAs layout design. Implemented in a 0.18-μm CMOS technology, the ADC's prototype occupied an area of 2.05 × 1.83 mm 2 . With a sampling rate of 120-MS/s and an input of 4.9 MHz, the ADC achieves a spurious-free-dynamic range of 74.32 dB and signal-to-noise-and-distortion ratio of 55.34 dB, while consuming 220-mW/channel at 3-V supply. (paper)

  17. Low Power Continuous-Time Delta-Sigma ADC with Current Output DAC

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2015-01-01

    CT ∆Σ ADC for audio applications, designed in a 0.18 µm CMOS process, with active-RC integrators, a 7-level Flash ADC quantizer and current output DAC for the feedback. From simulations the ADC achieves a dynamic range of 95.0 dB in the audio band, with a current consumption of 284 µA for a 1.7 V......The paper presents a continuous-time (CT) DeltaSigma (∆Σ) analog-to-digital converter (ADC) using a current output digital-to-analog converter (DAC) for the feedback. From circuit analysis it is shown that using a current output DAC makes it possible to relax the noise requirements of the 1st...

  18. Digitally assisted pipeline ADCs theory and implementation

    CERN Document Server

    Murmann, Boris

    2007-01-01

    List of Figures. List of Tables. Acknowledgements. Preface. 1: Introduction. 1. Motivation. 2. Overview. 3. Chapter Organization. 2: Performance Trends. 1. Introduction. 2. Digital Performance Trends. 3. ADC Performance Trends. 3: Scaling Analysis. 1. Introduction. 2. Basic Device Scaling from a Digital Perspective. 3. Technology Metrics for Analog Circuits. 4. Scaling Impact on Matching-Limited Circuits. 5. Scaling Impact on Noise-Limited Circuits. 4: Improving Analog Circuit Efficiency. 1. Introduction. 2. Analog Circuit Challenges. 3. The Cost of Feedback. 4. Two-Stage Feedback Amplifier vs. Open-Loop Gain Stage. 5. Discussion. 5: Open-Loop Pipelined ADCs. 1. A Brief Review of Pipelined ADCs. 2. Conventional Stage Implementation. 3. Open-Loop Pipeline Stages. 4. Alternative Transconductor Implementations. 6: Digital Nonlinearity Correction. 1. Overview. 2. Error Model and Digital Correction. 3. Alternative Error Models. 7: Statistics-Based Parameter Estimation. 1. Introduction. 2. Modulation Approach. 3. R...

  19. Dynamic testing of adhesive joints using a shock testing machine

    NARCIS (Netherlands)

    Aanhold, J.E. van; Weersink, A.F.J.; Ludolphy, J.W.L.

    1998-01-01

    A light-weight shock testing machine, designed for type approval testing of naval equipment up to 300 kg mass, has been modified into a dynamic tensile test rig. This enables to test structural details for high rate dynamic tensile loadings such as occur during underwater shock. The maximum capacity

  20. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    Energy Technology Data Exchange (ETDEWEB)

    Palmucci, S., E-mail: spalmucci@sirm.org; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-15

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm{sup 2}/sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm{sup 2}/s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm{sup 2}/s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm{sup 2}/s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to

  1. A 12-bit 500KSPS cyclic ADC for CMOS image sensor

    Science.gov (United States)

    Li, Zhaohan; Wang, Gengyun; Peng, Leli; Ma, Cheng; Chang, Yuchun

    2015-03-01

    At present, single-slope analog-to-digital convertor (ADC) is widely used in the readout circuits of CMOS image sensor (CIS) while its main drawback is the high demand for the system clock frequency. The more pixels and higher ADC resolution the image sensor system needs, the higher system clock frequency is required. To overcome this problem in high dynamic range CIS system, this paper presents a 12-bit 500-KS/s cyclic ADC, in which the system clock frequency is 5MHz. Therefore, comparing with the system frequency of 2N×fS for the single-slope ADC, where fS, N is the sampling frequency and resolution, respectively, the higher ADC resolution doesn't need the higher system clock frequency. With 0.18μm CMOS process, the circuit layout is realized and occupies an area of 8μm×374μm. Post simulation results show that Signal-to-Noise-and-Distortion-Ratio (SNDR) and Efficient Number of Bit (ENOB) reaches 63.7dB and 10.3bit, respectively.

  2. High performance photonic ADC for space applications

    Science.gov (United States)

    Pantoja, S.; Piqueras, M. A.; Villalba, P.; Martínez, B.; Rico, E.

    2017-11-01

    The flexibility required for future telecom payloads will require of more digital processing capabilities, moving from conventional analogue repeaters to more advanced and efficient analog subsystems or DSPbased solutions. Aggregate data throughputs will have to be handled onboard, creating the need for effective, ADC/DSP and DSP/DAC high speed links. Broadband payloads will have to receive, route and retransmit hundreds of channels and need to be designed so as to meet such requirements of larger bandwidth, system transparency and flexibility.[1][2] One important device in these new architectures is analog to digital converter (ADC) and its equivalent digital to analog converter (DAC). These will be the in/out interface for the use of digital processing in order to provide flexible beam to beam connectivity and variable bandwidth allocation. For telecom payloads having a large number of feeds and thus a large number of converters the mass and consumption of the mixer stage has become significant. Moreover, the inclusion of ADCs in the payload presents new trade-offs in design (jitter, quantization noise, ambiguity). This paper deals with an alternative solution of these two main problems with the exploitation of photonic techniques.

  3. Molecular dynamics simulation of impact test

    Energy Technology Data Exchange (ETDEWEB)

    Akahoshi, Y. [Kyushu Inst. of Tech., Kitakyushu, Fukuoka (Japan); Schmauder, S.; Ludwig, M. [Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt

    1998-11-01

    This paper describes an impact test by molecular dynamics (MD) simulation to evaluate embrittlement of bcc Fe at different temperatures. A new impact test model is developed for MD simulation. The typical fracture behaviors show transition from brittle to ductile fracture, and a history of the impact loads also demonstrates its transition. We conclude that the impact test by MD could be feasible. (orig.)

  4. Molecular dynamics simulation of impact test

    International Nuclear Information System (INIS)

    Akahoshi, Y.; Schmauder, S.; Ludwig, M.

    1998-01-01

    This paper describes an impact test by molecular dynamics (MD) simulation to evaluate embrittlement of bcc Fe at different temperatures. A new impact test model is developed for MD simulation. The typical fracture behaviors show transition from brittle to ductile fracture, and a history of the impact loads also demonstrates its transition. We conclude that the impact test by MD could be feasible. (orig.)

  5. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  6. Testing quantum dynamics in genetic information processing

    Indian Academy of Sciences (India)

    Unknown

    . Centre for Theoretical Studies, and Supercomputer Education and Research Centre,. Indian Institute of Science, Bangalore 560 012, India. Abstract. Does quantum dynamics play a role in DNA replication? What type of tests would reveal that ...

  7. Realistic dynamic stope support testing

    CSIR Research Space (South Africa)

    Ortlepp, WD

    2000-08-01

    Full Text Available mass of 10 000kg from a height of 3 metres to impact at a velocity of 7.7 m/s upon the target ‘rock mass’. The target mass was represented by a discontinuous but compact arrangement of steel-clad concrete blocks which would transmit and disperse... the concentrated impact load downward on to a collapsible roof. Carefully designed, shaped concrete blocks would represent the fractured hangingwall layer of the stope, the stability of which would be determined largely by the support system under test...

  8. Real time prediction and correction of ADCS problems in LEO satellites using fuzzy logic

    Directory of Open Access Journals (Sweden)

    Yassin Mounir Yassin

    2017-06-01

    Full Text Available This approach is concerned with adapting the operations of attitude determination and control subsystem (ADCS of low earth orbit LEO satellites through analyzing the telemetry readings received by mission control center, and then responding to ADCS off-nominal situations. This can be achieved by sending corrective operational Tele-commands within real time. Our approach is related to the fuzzy membership of off-nominal telemetry readings of corrective actions through a set of fuzzy rules based on understanding the ADCS modes resulted from the satellite telemetry readings. Response in real time gives us a chance to avoid risky situations. The approach is tested on the EgyptSat-1 engineering model, which is our method to simulate the results.

  9. Dynamic assertion testing of flight control software

    Science.gov (United States)

    Andrews, D. M.; Mahmood, A.; Mccluskey, E. J.

    1985-01-01

    An experiment in using assertions to dynamically test fault tolerant flight software is described. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters.

  10. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  11. Design and construction of the 8K multi-channel gamma spectrometer module (ADC+MCD)

    International Nuclear Information System (INIS)

    Vu Xuan Cach; Hoang Thi Ngoc Bich; Truong Van Dat; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Nguyen Xuan Hai

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram, implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. The 8K MCA module has the main following hardware specifications: ADC Successive-approximation type with sliding scale linearization; resolution: 8192 channels; dead time per event: 5 μs, including memory transfer; integral nonlinearity: ±0.025% over the top 98% of the dynamic range; differential nonlinearity: < ±1% over the top 98% of the dynamic range; data memory: 224 counts per channel (16 millions counts); presets; Real Time/Live Time: 1 to 232(s), Multiples of 1 s; ADC LLD and ULD Aajustable from 0 to 100% of full scale via hardware control; input accepts positive unipolar pulses in

  12. 12-bit 32 channel 500 MS/s low-latency ADC for particle accelerators real-time control

    Science.gov (United States)

    Karnitski, Anton; Baranauskas, Dalius; Zelenin, Denis; Baranauskas, Gytis; Zhankevich, Alexander; Gill, Chris

    2017-09-01

    Particle beam control systems require real-time low latency digital feedback with high linearity and dynamic range. Densely packed electronic systems employ high performance multichannel digitizers causing excessive heat dissipation. Therefore, low power dissipation is another critical requirement for these digitizers. A described 12-bit 500 MS/s ADC employs a sub-ranging architecture based on a merged sample & hold circuit, a residue C-DAC and a shared 6-bit flash core ADC. The core ADC provides a sequential coarse and fine digitization featuring a latency of two clock cycles. The ADC is implemented in a 28 nm CMOS process and consumes 4 mW of power per channel from a 0.9 V supply (interfacing and peripheral circuits are excluded). Reduced power consumption and small on-chip area permits the implementation of 32 ADC channels on a 10.7 mm2 chip. The ADC includes a JESD204B standard compliant output data interface operated at the 7.5 Gbps/ch rate. To minimize the data interface related time latency, a special feature permitting to bypass the JESD204B interface is built in. DoE Phase I Award Number: DE-SC0017213.

  13. A 72-dB-SNDR rail-to-rail successive approximation ADC using mismatch calibration techniques

    International Nuclear Information System (INIS)

    Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2012-01-01

    When the voltage of an analog input signal is equal to the supply voltage, it is difficult for a conventional successive approximation ADC to correctly convert the analog signal into digital signal. This paper introduces an improved successive approximation ADC, which can convert the rail-to-rail input range and reduce sampling time through a track-and-hold circuit. Comparator offset cancellation and capacitor self-calibration techniques are used in this ADC. Measurement results show that the peak SNDR of this ADC reaches 72 dB and the signal effective bandwidth is up to 1.25 MHz. It consumes 1 mW in the test, and the figure of merit is 123 fJ/conversion-step. (semiconductor integrated circuits)

  14. Continuous waves probing in dynamic acoustoelastic testing

    Science.gov (United States)

    Scalerandi, M.; Gliozzi, A. S.; Ait Ouarabi, M.; Boubenider, F.

    2016-05-01

    Consolidated granular media display a peculiar nonlinear elastic behavior, which is normally analysed with dynamic ultrasonic testing exploiting the dependence on amplitude of different measurable quantities, such as the resonance frequency shift, the amount of harmonics generation, or the break of the superposition principle. However, dynamic testing allows measuring effects which are averaged over one (or more) cycles of the exciting perturbation. Dynamic acoustoelastic testing has been proposed to overcome this limitation and allow the determination of the real amplitude dependence of the modulus of the material. Here, we propose an implementation of the approach, in which the pulse probing waves are substituted by continuous waves. As a result, instead of measuring a time-of-flight as a function of the pump strain, we study the dependence of the resonance frequency on the strain amplitude, allowing to derive the same conclusions but with an easier to implement procedure.

  15. A Novel Digital Background Calibration Technique for 16 bit SHA-less Multibit Pipelined ADC

    Directory of Open Access Journals (Sweden)

    Swina Narula

    2016-01-01

    Full Text Available In this paper, a high resolution of 16 bit and high speed of 125MS/s, multibit Pipelined ADC with digital background calibration is presented. In order to achieve low power, SHA-less front end is used with multibit stages. The first and second stages are used here as a 3.5 bit and the stages from third to seventh are of 2.5 bit and last stage is of 3-bit flash ADC. After bit alignment and truncation of total 19 bits, 16 bits are used as final digital output. To precise the remove linear gain error of the residue amplifier and capacitor mismatching error, a digital background calibration technique is used, which is a combination of signal dependent dithering (SDD and butterfly shuffler. To improve settling time of residue amplifier, a special circuit of voltage separation is used. With the proposed digital background calibration technique, the spurious-free dynamic range (SFDR has been improved to 97.74 dB @30 MHz and 88.9 dB @150 MHz, and the signal-to-noise and distortion ratio (SNDR has been improved to 79.77 dB @ 30 MHz, and 73.5 dB @ 150 MHz. The implementation of the Pipelined ADC has been completed with technology parameters of 0.18μm CMOS process with 1.8 V supply. Total power consumption is 300 mW by the proposed ADC.

  16. ORIGINAL ARTICLE Value of apparent diffusion coefficient (ADC) in ...

    African Journals Online (AJOL)

    of DWI-MRI in the treatment of brain tumours and found that malignant tumours, owing to their high cellularity, have a restriction of water movement (diffusion) reflected by a low ADC value; and, when the tumours respond to treatment, the ADC value will increase. (less restriction of water movement) because of a decrease in ...

  17. Semi-autonomous controller for data acquisition, the Brilliant ADC

    International Nuclear Information System (INIS)

    Breidenbach, M.; Frank, E.; Hall, J.; Nelson, D.

    1977-10-01

    A set of high speed 16-bit computers and ADC's designed and built for the data collection, compression, and correction system of the SLAC/LBL Mark II Magnetic Detector. The ''Brilliant ADC'' controls the analog multiplexing of a CAMAC crate of data acquisition modules, digitizes the analog data, and executes microprogrammed algorithms for data handling and correction

  18. Dynamic Response Testing in an Electrically Heated Reactor Test Facility

    Science.gov (United States)

    Bragg-Sitton, Shannon M.; Morton, T. J.

    2006-01-01

    Non-nuclear testing can be a valuable tool in development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system (Bragg-Sitton, 2005). The current paper applies the same testing methodology to a direct drive gas cooled reactor system, demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. In each testing application, core power transients were controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. Although both system designs utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility.

  19. Childhood attachment and schizophrenia: the "attachment-developmental-cognitive" (ADC) hypothesis.

    Science.gov (United States)

    Rajkumar, Ravi Philip

    2014-09-01

    Schizophrenia is a complex psychiatric syndrome whose exact causes remain unclear. However, current scientific consensus has highlighted the importance of neurodevelopmental and neurocognitive processes in the development of schizophrenic symptoms. Research over the past three decades, motivated by the findings of the World Health Organization's large-scale studies, has highlighted the importance of psychosocial adversities - including childhood abuse and neglect - in this disorder. In this paper, I propose a hypothesis based on John Bowlby's framework of attachment theory, which I have termed the attachment-developmental-cognitive (ADC) hypothesis. The ADC hypothesis integrates recent developments related to (1) existing models of schizophrenia, (2) studies examining the effect of attachment on brain biology and cognitive development, and (3) various known facts about the course and outcome of this disorder. In doing so, it explains how disturbed childhood attachment leads to core psychological and neurochemical abnormalities which are implicated in the genesis of schizophrenia and also affect its outcome. The ADC hypothesis compasses and expands on earlier formulations, such as the "social defeat" and "traumagenic" models, and has important implications regarding the prevention and treatment of schizophrenia. Ways of testing and refining this hypothesis are outlined as avenues for future research. Though provisional, the ADC hypothesis is entirely consistent with both biological and psychosocial research into the origins of schizophrenia. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. ADC biomarker for head and neck tumors

    Science.gov (United States)

    Pacheco-Bravo, Irlanda; Hidalgo-Tobon, Silvia; Zaragoza, Kena; Reynoso-Noverón, Nancy; De Celis-Alonso, Benito; Delgado-Hernandez, Rosa

    2014-11-01

    According to the World Cancer Report, by 2020, global incidence of cancer may increase by 50%, which means 15 million new cases. In 2000, malignant tumors were the cause of 12% of the almost 56 million deaths worldwide due to all causes[1-4]. 18 men and 19 women, with an average age of 53 ± 14 years with diagnosis of head and neck cancer were scanned using a 1.5-T MR imaging unit (Signa HDxt; GE Medical Systems). Echo-planar DW imaging was performed in the transverse plane before the contrast material injection. Three b values were applied: 40, 100, and 800 sec/mm2. Primary tumors and nodes were evaluated, with diameters greater than 43 ± 15mm. In our study, ADC data for b-values of 40 showed correlation for identification of malignancy in primary tumors, and in the case of nodes there is a tendency toward malignancy in sequences in which a b-value of 800 is used.

  1. The Finite Deformation Dynamic Sphere Test Problem

    Energy Technology Data Exchange (ETDEWEB)

    Versino, Daniele [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brock, Jerry Steven [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-02

    In this manuscript we describe test cases for the dynamic sphere problem in presence of finite deformations. The spherical shell in exam is made of a homogeneous, isotropic or transverse isotropic material and elastic and elastic-plastic material behaviors are considered. Twenty cases, (a) to (t), are thus defined combining material types and boundary conditions. The inner surface radius, the outer surface radius and the material's density are kept constant for all the considered test cases and their values are ri = 10mm, ro = 20mm and p = 1000Kg/m3 respectively.

  2. Diffusion-weighted MR imaging and ADC mapping in differentiating benign from malignant thyroid nodules

    International Nuclear Information System (INIS)

    Khizer, A.T.; Slehria, A.U.R.

    2015-01-01

    To determine the diagnostic accuracy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping in differentiating benign from malignant thyroid nodules by taking histopathology as the gold standard. Study Design:Across-sectional analytical study. Place and Duration of Study: Department of Radiology at Combined Military Hospital (CMH), Lahore, from August 2012 to July 2013. Methodology: Thirty-five patients, who were referred to radiology department of CMH, Lahore, for ultrasound or Fine Needle Aspiration Cytology (FNAC) of thyroid gland, fulfilling the inclusion and exclusion criteria, were included in the study. They were evaluated on 1.5 Tesla MRI machine with T1- and T2-weighted imaging as well as fat-suppressed technique. DWI was done using b-values of 0 and 1000 s/mm2 and ADC values were calculated for the thyroid nodules. All of these patients were subjected to ultrasound guided core biopsy and histopathology results were correlated with ADC values. Results: The benign nodules showed facilitated diffusion while malignant nodules showed restricted diffusion. T-test was used to assess the difference in mean ADC values between benign and malignant nodules. The mean ADC value of the malignant thyroid nodules (0.94 ± 0.16 x 10/sup -3/mm2/s) was significantly lower than that of the benign thyroid nodules (1.93 ±0.13 x 10/sup -3/mm2/s) (p-value < 0.05). ADC value of 1.6 x 10/sup -3/mm2/s was used as a cut-off, for differentiating benign from malignant thyroid nodules. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of DWI and ADC values in differentiating benign from malignant thyroid nodules were 93%, 95%, 93%, 95% and 92.3%, respectively. Conclusion: DWI is a non-invasive diagnostic tool for characterization and differentiation between benign and malignant thyroid nodules. It not only decreases the burden of unnecessary surgeries when pre-operative FNAC and biopsy are inconclusive, but is also helpful in reaching a

  3. A 12-bit 1-MS/s 26-μW SAR ADC for Sensor Applications

    Science.gov (United States)

    Chung, Yung-Hui; Yen, Chia-Wei; Tsai, Cheng-Hsun

    2018-01-01

    This chapter presents an energy-efficient 12-bit 1-MS/s successive approximation register analog-to-digital converter (ADC) for sensor applications. A programmable dynamic comparator is proposed to suppress static current and maintain good linearity. A hybrid charge redistribution digital-to-analog converter is proposed to decrease the total capacitance, which would reduce the power consumption of the input and reference buffers. In the proposed ADC, its total input capacitance is only 700 fF, which greatly reduces the total power consumption of the analog frontend circuits. The 12-bit ADC is fabricated using 0.18-μm complementary metal-oxidesemiconductor technology, and it consumes only 26 μW from a 1 V supply at 1-MS/s. The measured signal-to-noise-and-distortion ratio (SNDR) and spurious-free dynamic range (SFDR) are 60.1 and 72.6 dB, respectively. The measured effective number of bits (ENOB) for a 100 kHz input frequency is 9.7 bits. At the Nyquist input frequency, the measured SNDR and SFDR are 59.7 and 71 dB, respectively. The ENOB is maintained at 9.6 bits and the figure-of-merit is 33.5 fJ/conversion-step.

  4. A 14-bit 100-MS/s 85.2-dB SFDR pipelined ADC without calibration

    Science.gov (United States)

    Nan, Zhao; Hua, Luo; Qi, Wei; Huazhong, Yang

    2014-07-01

    This paper describes a 14-bit 100-MS/s calibration-free pipelined analog-to-digital converter (ADC). Choices for stage resolution as well as circuit topology are carefully considered to obtain high linearity without any calibration algorithm. An adjusted timing diagram with an additional clock phase is proposed to give residue voltage more settling time and minimize its distortion. The ADC employs an LVDS clock input buffer with low-jitter consideration to ensure good performance at high sampling rate. Implemented in a 0.18-μm CMOS technology, the ADC prototype achieves a spurious free dynamic range (SFDR) of 85.2 dB and signal-to-noise-and-distortion ratio (SNDR) of 63.4 dB with a 19.1-MHz input signal, while consuming 412-mW power at 2.0-V supply and occupying an area of 2.9 × 3.7mm2.

  5. A low power 12-bit ADC for nuclear instrumentation

    International Nuclear Information System (INIS)

    Adachi, R.; Landis, D.; Madden, N.; Silver, E.; LeGros, M.

    1992-10-01

    A low power, successive approximation, analog-to-digital converter (ADC) for low rate, low cost, battery powered applications is described. The ADC is based on a commercial 50 mW successive approximation CMOS device (CS5102). An on-chip self-calibration circuit reduces the inherent differential nonlinearity to 7%. A further reduction of the differential nonlinearity to 0.5% is attained with a four bit Gatti function. The Gatti function is distributed to minimize battery power consumption. All analog functions reside with the ADC while the noisy digital functions reside in the personal computer based histogramming memory. Fiber optic cables carry afl digital information between the ADC and the personal computer based histogramming memory

  6. Photonic-assisted time-interleaved ADC based on optical delay line

    International Nuclear Information System (INIS)

    Xu, Chen; Zheng, Shilie; Chen, Xinyi; Chi, Hao; Jin, Xiaofeng; Zhang, Xianmin

    2016-01-01

    An approach to implement photonic-assisted time-interleaved analog-to-digital conversion and its calibration method are presented. The analog modulated optical signal is divided into M channels, suffering different time delay induced by optical delay lines which provide great flexibility in producing time intervals and is then sampled by electronic analog-to-digital converters (ADCs). The channel mismatches resulting in performance degradation are estimated by a modified sine wave fitting method. The time mismatch and other mismatches are corrected by fine optical delay adjustment and digital processing, respectively. A four-channel photonic-assisted time-interleaved analog-to-digital converter (TIADC) system operating at 40 GSa s −1 was demonstrated experimentally. The photonic-assisted TIADC system was tested with a 6.31 GHz sine wave signal, exhibiting 40.3 dB signal-to-noise and distortion ratio (SINAD) and 57.6 dBc spurious-free dynamic range (SFDR). It is shown that the SINAD is dominated by the signal-to-noise ratio (SNR) of the analog optical link and the SFDR of the proposed system is limited by the linearity of the link. (paper)

  7. A 1.2-V 165-μW 0.29-mm² Multibit Sigma-Delta ADC for Hearing Aids Using Nonlinear DACs and With Over 91 dB Dynamic-Range

    DEFF Research Database (Denmark)

    Custódio, José R.; Goes, João; Paulino, Nuno

    2013-01-01

    This paper describes the design and experimental evaluation of a multibit Sigma-Delta (ΣΔ) modulator (ΣΔM) with enhanced dynamic range (DR) through the use of nonlinear digital-to-analog converters (DACs) in the feedback paths. This nonlinearity imposes a trade-off between DR and distortion, whic...

  8. Cerebral and cerebellar ADC values during a migraine attack

    International Nuclear Information System (INIS)

    Degirmenci, Bumin; Haktanir, Alpay; Albayrak, Ramazan; Acar, Murat; Yaman, Mehmet

    2007-01-01

    We investigated the diffusion-weighted MRI changes, apparent diffusion coefficient (ADC) values, and conventional MRI findings in specific brain areas during migraine attacks in patients with and without aura. Included in the study were 22 patients (2 male, 20 female) aged between 17 and 49 years who were diagnosed as having migraine according to the diagnostic criteria of the International Headache Society. Also included in the study were 18 age- and sex-matched healthy volunteers. Hyperintense lesions were evaluated in conventional MR images. Heavily diffusion-weighted images, ADC maps, and segmented ADC maps generated for regional ADC (rADC) measurements, were also studied. ADC values from specific brain areas were used with appropriate region of interests (ROI). Migraine with aura was diagnosed in 13 patients and migraine without aura was diagnosed in 9 patients. A total of 23 hyperintense lesions within the periventricular white matter and deep white matter were detected in five patients (21.8%). All of these hyperintense lesions were seen in migraine patients with aura. In only one patient did a hyperintense lesion show an increased diffusion pattern on diffusion-weighted images and ADC maps. One hyperintense lesion was detected in the control group (5.5%). There was no significant difference in ADC values between the migraine and control groups. T2-weighted hyperintense lesions were significantly more frequent in migraine patients especially in those with aura than in the control group. No diffusion alterations in diffusion-weighted images were detected in the infra- and supratentorial brain areas during migraine attacks in patients with and without aura. (orig.)

  9. Testing relativity with solar system dynamics

    Science.gov (United States)

    Hellings, R. W.

    1984-01-01

    A major breakthrough is described in the accuracy of Solar System dynamical tests of relativistic gravity. The breakthrough was achieved by factoring in ranging data from Viking Landers 1 and 2 from the surface of Mars. Other key data sources included optical transit circle observations, lunar laser ranging, planetary radar, and spacecraft (Mariner 9 to Mars and Mariner 10 to Mercury). The Solar System model which is used to fit the data and the process by which such fits are performed are explained and results are discussed. The results are fully consistent with the predictions of General Relativity.

  10. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. A 1.33 μW 8.02-ENOB 100 kS/s successive approximation ADC with supply reduction technique for implantable retinal prosthesis.

    Science.gov (United States)

    Tang, Howard; Sun, Zhuo Chao; Chew, Kin Wai Roy; Siek, Liter

    2014-12-01

    This paper presents a chip level 9 bits Charge Folding Successive-Approximation-Register (SAR) Analog-to-Digital Converter (ADC) to be used in a CMOS image sensor for retinal prosthesis. It has a maximum single-ended input range of 1.8 V but only uses a supply voltage of 0.9 V for the entire ADC through the Charge Folding method. Therefore, the input range is no longer limited by the supply rail as in conventional SAR ADC. Moreover, the ADC is controlled by an internal delay line based Asynchronous Clock Generator which can be programmed to adjust the resolution of the ADC from 5 to 9 bits. Therefore, resolution adaptation function can be applied to improve the energy efficiency up to 15%. The test chip is implemented in 0.18 μm CMOS process and occupies an area of 0.15 mm(2). At 0.9 V and 100 kS/s, the 9 bit s ADC consumes 1.33 μW and achieves an energy efficiency of 51.3 fJ/conversion-step . In addition, the power consumption can be further reduced by scaling the supply voltage and sampling frequency. At 100 kS/s, this ADC is capable of converting the input signal at a rate equivalent to 30 frames/s for a pixel array up to 3200 pixels.

  12. A 6-bit 3-Gsps ADC implemented in 1 μm GaAs HBT technology

    International Nuclear Information System (INIS)

    Zhang Jincan; Zhang Yuming; Lü Hongliang; Zhang Yimen; Xiao Guangxing; Ye Guiping

    2014-01-01

    The design and test results of a 6-bit 3-Gsps analog-to-digital converter (ADC) using 1 μm GaAs heterojunction bipolar transistor (HBT) technology are presented. The monolithic folding-interpolating ADC makes use of a track-and-hold amplifier (THA) with a highly linear input buffer to maintain a highly effective number of bits (ENOB). The ADC occupies an area of 4.32 × 3.66 mm 2 and achieves 5.53 ENOB with an effective resolution bandwidth of 1.1 GHz at a sampling rate of 3 Gsps. The maximum DNL and INL are 0.36 LSB and 0.48 LSB, respectively. (semiconductor integrated circuits)

  13. Dynamic leaching test of personal computer components.

    Science.gov (United States)

    Li, Yadong; Richardson, Jay B; Niu, Xiaojun; Jackson, Ollie J; Laster, Jeremy D; Walker, Aaron K

    2009-11-15

    A dynamic leaching test (DLT) was developed and used to evaluate the leaching of toxic substances for electronic waste in the environment. The major components in personal computers (PCs) including motherboards, hard disc drives, floppy disc drives, and compact disc drives were tested. The tests lasted for 2 years for motherboards and 1.5 year for the disc drives. The extraction fluids for the standard toxicity characteristic leaching procedure (TCLP) and synthetic precipitation leaching procedure (SPLP) were used as the DLT leaching solutions. A total of 18 elements including Ag, Al, As, Au, Ba, Be, Cd, Cr, Cu, Fe, Ga, Ni, Pd, Pb, Sb, Se, Sn, and Zn were analyzed in the DLT leachates. Only Al, Cu, Fe, Ni, Pb, and Zn were commonly found in the DLT leachates of the PC components. Their leaching levels were much higher in TCLP extraction fluid than in SPLP extraction fluid. The toxic heavy metal Pb was found to continuously leach out of the components over the entire test periods. The cumulative amounts of Pb leached out of the motherboards in TCLP extraction fluid reached 2.0 g per motherboard over the 2-year test period, and that in SPLP extraction fluid were 75-90% less. The leaching rates or levels of Pb were largely affected by the content of galvanized steel in the PC components. The higher was the steel content, the lower the Pb leaching rate would be. The findings suggest that the obsolete PCs disposed of in landfills or discarded in the environment continuously release Pb for years when subjected to landfill leachate or rains.

  14. Testing particle filters on convective scale dynamics

    Science.gov (United States)

    Haslehner, Mylene; Craig, George. C.; Janjic, Tijana

    2014-05-01

    Particle filters have been developed in recent years to deal with highly nonlinear dynamics and non Gaussian error statistics that also characterize data assimilation on convective scales. In this work we explore the use of the efficient particle filter (P.v. Leeuwen, 2011) for convective scale data assimilation application. The method is tested in idealized setting, on two stochastic models. The models were designed to reproduce some of the properties of convection, for example the rapid development and decay of convective clouds. The first model is a simple one-dimensional, discrete state birth-death model of clouds (Craig and Würsch, 2012). For this model, the efficient particle filter that includes nudging the variables shows significant improvement compared to Ensemble Kalman Filter and Sequential Importance Resampling (SIR) particle filter. The success of the combination of nudging and resampling, measured as RMS error with respect to the 'true state', is proportional to the nudging intensity. Significantly, even a very weak nudging intensity brings notable improvement over SIR. The second model is a modified version of a stochastic shallow water model (Würsch and Craig 2013), which contains more realistic dynamical characteristics of convective scale phenomena. Using the efficient particle filter and different combination of observations of the three field variables (wind, water 'height' and rain) allows the particle filter to be evaluated in comparison to a regime where only nudging is used. Sensitivity to the properties of the model error covariance is also considered. Finally, criteria are identified under which the efficient particle filter outperforms nudging alone. References: Craig, G. C. and M. Würsch, 2012: The impact of localization and observation averaging for convective-scale data assimilation in a simple stochastic model. Q. J. R. Meteorol. Soc.,139, 515-523. Van Leeuwen, P. J., 2011: Efficient non-linear data assimilation in geophysical

  15. Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems.

    Science.gov (United States)

    Tang, Wei; Osman, Ahmad; Kim, Dongsoo; Goldstein, Brian; Huang, Chenxi; Martini, Berin; Pieribone, Vincent A; Culurciello, Eugenio

    2013-06-01

    In this paper we present a fixed window level crossing sampling analog to digital convertor for bio-potential recording sensors. This is the first proposed and fully implemented fixed window level crossing ADC without local DACs and clocks. The circuit is designed to reduce data size, power, and silicon area in future wireless neurophysiological sensor systems. We built a testing system to measure bio-potential signals and used it to evaluate the performance of the circuit. The bio-potential amplifier offers a gain of 53 dB within a bandwidth of 200 Hz-20 kHz. The input-referred rms noise is 2.8 µV. In the asynchronous level crossing ADC, the minimum delta resolution is 4 mV. The input signal frequency of the ADC is up to 5 kHz. The system was fabricated using the AMI 0.5 µm CMOS process. The chip size is 1.5 mm by 1.5 mm. The power consumption of the 4-channel system from a 3.3 V supply is 118.8 µW in the static state and 501.6 µW with a 240 kS/s sampling rate. The conversion efficiency is 1.6 nJ/conversion.

  16. PEALL4: a 4-channel, 12-bit, 40-MSPS, Power Efficient and Low Latency SAR ADC

    Science.gov (United States)

    Rarbi, F.; Dzahini, D.; Gallin-Martel, L.; Bouvier, J.; Zeloufi, M.; Trocme, B.; Gabaldon Ruiz, C.

    2015-01-01

    The PEALL4 chip is a Power Efficient And Low Latency 4-channels, 12-bit and 40-MSPS successive approximation register (SAR) ADC. It was designed featuring a very short latency time in the context of ATLAS Liquid Argon Calorimeter phase I upgrade. Moreover this design could be a good option for ATLAS phase II and other High Energy Physics (HEP) projects. The full functionality of the converter is achieved by an embedded high-speed clock frequency conversion generated by the ADC itself. The design and testing results of the PEALL4 chip implemented in a commercial 130nm CMOS process are presented. The size of this 4-channel ADC with embedded voltage references and sLVS output serializer is 2.8x3.4 mm2. The chip presents a short latency time less than 25 ns defined from the very beginning of the sampling to the last conversion bit made available. A total power consumption below 27mW per channel is measured including the reference buffer and the sLVS serializer.

  17. CUSTOMER PERCEPTION ON ALTERNATIVE DELIVERY CHANNEL (ADC OF BANKS IN BANGLADESH

    Directory of Open Access Journals (Sweden)

    Shahed BIN SADIQUE

    2016-12-01

    Full Text Available This paper aims at understanding the level of customer’s perception on alternative delivery channel of different commercial schedule banks of Bangladesh. Considering the significant development in technology and for sustainability, banking industry in Bangladesh has expanded banking operation through offering different ADCs to attract customers which are ultimately changing the perception of customers in the long run. Based on this reality, data were collected from a survey and a usable sample of 134 was taken for analysis. KAPPA test and multiple regression model is used to analyze the overall consistency of respondent’s responses and measurement of consumers’ perception. The results of the survey show that visibility, availability, self-security, confidential transaction ability, easiness and simplicity in the procedure of ADC makes it more attractive to consumer. The findings also suggest that security of physical establishment of ADC is vital though banks have given less importance to it. From the study, it is found that in order to change perception and to attract more users to banking; it is not going to be enough to make the system easy to interact with. Banks should develop more secured and private alternative delivery channels that will be reliable to their customers. Thus, management attention might be effectively focused on the development of such sectors that have been properly identified in this research.

  18. Customer Perception on Alternative Delivery Channel (ADC of Banks in Bangladesh

    Directory of Open Access Journals (Sweden)

    Shahed BIN SADIQUE

    2016-12-01

    Full Text Available This paper aims at understanding the level of customer’s perception on alternative delivery channel of different commercial schedule banks of Bangladesh. Considering the significant development in technology and for sustainability, banking industry in Bangladesh has expanded banking operation through offering different ADCs to attract customers which are ultimately changing the perception of customers in the long run. Based on this reality, data were collected from a survey and a usable sample of 134 was taken for analysis. KAPPA test and multiple regression model is used to analyze the overall consistency of respondent’s responses and measurement of consumers’ perception. The results of the survey show that visibility, availability, self-security, confidential transaction ability, easiness and simplicity in the procedure of ADC makes it more attractive to consumer. The findings also suggest that security of physical establishment of ADC is vital though banks have given less importance to it. From the study, it is found that in order to change perception and to attract more users to banking; it is not going to be enough to make the system easy to interact with. Banks should develop more secured and private alternative delivery channels that will be reliable to their customers. Thus, management attention might be effectively focused on the development of such sectors that have been properly identified in this research.

  19. Infratentorial tumors in children – value of ADC in prediction of grade of neoplasms

    International Nuclear Information System (INIS)

    Jurkiewicz, Elżbieta; Pakuła-Kościesza, Iwona; Chełstowska, Sylwia; Nowak, Katarzyna; Roszkowski, Marcin; Grajkowska, Wiesława; Szary, Cezary

    2010-01-01

    The purpose of this study was to evaluate ADC values in the preoperative grading of primary infratentorial brain tumors in children. We retrospectively reviewed 50 MR examinations of patients with infratentorial tumors. All children were operated on and tumors were histopathologically proved as low-grade – 25 (24 pilocytic astrocytomas, 1 ependymoma) and high-grade lesions – 25 (19 medulloblastomas, 6 anaplastic ependymomas). In all patients with contrast-enhanced tumors, ROIs were placed in the enhanced region. In patients with non-enhancing tumors, ROIs were placed in the solid part of the lesion. Cystic, hemorrhagic and necrotic areas of tumors were excluded. Statistical analysis was performed by using a Student’s t-test. Statistically significant differences were found in the comparisons of mean ADC of pilocytic astrocytomas (1.54×10 −3 mm 2 /s ±0.2) with medulloblastomas (0.75×10 −3 mm 2 /s ±0.075) and pilocytic astrocytomas (1.54×10 −3 mm 2 /s ±0.2) with anaplastic ependymomas (0.99×10 −3 mm 2 /s ±0.25). Statistical analysis including ependymomas should be discussed, because of small number of these tumors and a non-homogenous group of lesions. DWI imaging and ADC map provide useful information for preoperative grading of infratentorial tumors in children

  20. Methods to Design and Synthesize Antibody-Drug Conjugates (ADCs

    Directory of Open Access Journals (Sweden)

    Houzong Yao

    2016-02-01

    Full Text Available Antibody-drug conjugates (ADCs have become a promising targeted therapy strategy that combines the specificity, favorable pharmacokinetics and biodistributions of antibodies with the destructive potential of highly potent drugs. One of the biggest challenges in the development of ADCs is the application of suitable linkers for conjugating drugs to antibodies. Recently, the design and synthesis of linkers are making great progress. In this review, we present the methods that are currently used to synthesize antibody-drug conjugates by using thiols, amines, alcohols, aldehydes and azides.

  1. Asphalt mix characterization using dynamic modulus and APA testing.

    Science.gov (United States)

    2005-11-01

    final report summarizes two research efforts related to asphalt mix characterization: dynamic modulus and Asphalt Pavement Analyzer testing. One phase of the research consisted of a laboratory-based evaluation of dynamic modulus of Oregon dense-grade...

  2. Testing substellar models with dynamical mass measurements

    Directory of Open Access Journals (Sweden)

    Liu M.C.

    2011-07-01

    Full Text Available We have been using Keck laser guide star adaptive optics to monitor the orbits of ultracool binaries, providing dynamical masses at lower luminosities and temperatures than previously available and enabling strong tests of theoretical models. We have identified three specific problems with theory: (1 We find that model color–magnitude diagrams cannot be reliably used to infer masses as they do not accurately reproduce the colors of ultracool dwarfs of known mass. (2 Effective temperatures inferred from evolutionary model radii are typically inconsistent with temperatures derived from fitting atmospheric models to observed spectra by 100–300 K. (3 For the only known pair of field brown dwarfs with a precise mass (3% and age determination (≈25%, the measured luminosities are ~2–3× higher than predicted by model cooling rates (i.e., masses inferred from Lbol and age are 20–30% larger than measured. To make progress in understanding the observed discrepancies, more mass measurements spanning a wide range of luminosity, temperature, and age are needed, along with more accurate age determinations (e.g., via asteroseismology for primary stars with brown dwarf binary companions. Also, resolved optical and infrared spectroscopy are needed to measure lithium depletion and to characterize the atmospheres of binary components in order to better assess model deficiencies.

  3. Model tests on dynamic performance of RC shear walls

    International Nuclear Information System (INIS)

    Nagashima, Toshio; Shibata, Akenori; Inoue, Norio; Muroi, Kazuo.

    1991-01-01

    For the inelastic dynamic response analysis of a reactor building subjected to earthquakes, it is essentially important to properly evaluate its restoring force characteristics under dynamic loading condition and its damping performance. Reinforced concrete shear walls are the main structural members of a reactor building, and dominate its seismic behavior. In order to obtain the basic information on the dynamic restoring force characteristics and damping performance of shear walls, the dynamic test using a large shaking table, static displacement control test and the pseudo-dynamic test on the models of a shear wall were conducted. In the dynamic test, four specimens were tested on a large shaking table. In the static test, four specimens were tested, and in the pseudo-dynamic test, three specimens were tested. These tests are outlined. The results of these tests were compared, placing emphasis on the restoring force characteristics and damping performance of the RC wall models. The strength was higher in the dynamic test models than in the static test models mainly due to the effect of loading rate. (K.I.)

  4. ORIGINAL ARTICLE Value of apparent diffusion coefficient (ADC) in ...

    African Journals Online (AJOL)

    and National Hospital Complex, in Bloemfontein. Women of all ages. Value of apparent diffusion coefficient (ADC) in evaluating response of carcinoma of the cervix treated with chemoradiotherapy. A le Roux, F Gebremariam, W Harmse. Department of Diagnostic Radiology, Faculty of Health Sciences, University of the Free ...

  5. ADC Clock Jitter Requirements for Software Radio Receivers

    NARCIS (Netherlands)

    Arkesteijn, V.J.; Klumperink, Eric A.M.; Nauta, Bram

    The effective number of bits of an analogue-to-digital converter (ADC) is limited not only by the quantisation step inaccuracy, but also by sampling time uncertainty. According to a commonly used model, timing jitter errors should not introduce a sampling error bigger than 1 quantisation level for

  6. High precision 16K, 16 channel peak sensing CAMAC ADC

    International Nuclear Information System (INIS)

    Jain, Mamta; Subramaniam, E.T

    2013-01-01

    A high density, peak sensing, analog to digital converter (ADC) double width module with CAMAC back plane has been developed for nuclear physics experiments with a large number of detectors. This module has sixteen independent channels in plug-in daughter card mother board mode

  7. ADC's Insertion Devices and Magnetic Measurement Systems Capabilities

    Science.gov (United States)

    Deyhim, A.; Kulesza, J.

    2013-03-01

    In this paper Advance Design Consulting USA, Inc. (ADC) will discuss ADC's major improved capabilities for building Wiggler Insertion Devices, Undulator Planar Devices, Elliptical Polarizing Undulators (EPU), In-Vacuum Undulators (IVU), Cryogenically Cooled in-vacuum Undulators (CPMU), Super Conductive Undulator, and Insertion Device Magnetic Measurement Systems. ADC has designed, built and delivered Insertion Devices and Magnetic Measurement Systems to such facilities as MAX-lab (two EPUs, a Planar, and Measurement System), ALBA and ASP (Wigglers), BNL (CPMU), SSRF (two IVUs and a Measurement System), PAL (one IVU and Measurement System), NSRRC (one 4m EPU), and SRC (Planar and EPU). ADC's magnetic field measurement system is a sophisticated and sensitive machine for the measurement of magnetic fields in undulators (Planar and EPU), wigglers and in-vacuum ID units. The magnetic fields are measured using 3 axis hall-effect probes, mounted orthogonally, to a thin wand. The wand is mounted to a carriage that rides on vacuum air bearings. The base is granite. A flip coil is provided on two vertical towers with X, Y and Theta axes. Special software is provided to assist in homing, movement, and data collection and analysis.

  8. Value of apparent diffusion coefficient (ADC) in evaluating response ...

    African Journals Online (AJOL)

    Objective. To determine whether the apparent diffusion coefficient (ADC) value obtained by diffusion-weighted magnetic resonance imaging (DW-MRI) can be used as a reliable detector of response of carcinoma of the cervix treated with chemoradiotherapy, compared with conventional. T2-weighted MRI. Design.

  9. [Testing of dynamic multileaf collimator by dynamic log file].

    Science.gov (United States)

    Ono, Kaoru; Nakamura, Tetsuji; Yamato, Shinichirou; Miyazawa, Masanori

    2007-07-20

    Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy. In the dynamic multileaf collimator (MLC) method of IMRT delivery, because of the relatively small gaps between opposed leaves and because most regions are shielded by leaves most of the time, the delivered dose is very sensitive to MLC leaf positional accuracy. A variation of +/-0.2 mm in the gap width can result in a dose variation of +/-3% for each clinical dynamic MLC field. Most often the effects of leaf motion are inferred from dose deviations on film or from variations in ionization measurements. These techniques provide dosimetric information but do not provide detailed information for diagnosing delivery problems. Therefore, a dynamic log file (Dynalog file) was used to verify dynamic MLC leaf positional accuracy. Measuring for narrow gaps using the thickness gauge could detect a log file accuracy of approximately 0.1 mm. The accuracy of dynamic MLC delivery depends on the accuracy with which the velocity of each leaf is controlled. We studied the relationship between leaf positional accuracy and leaf velocity. Leaf velocity of 0.7 cm/sec caused approximately 0.2 mm leaf positional variation. We then analyzed leaf positional accuracy for the clinical dynamic MLC field using Dynalog File Viewer (Varian Medical Systems, Inc., Palo Alto, CA), and developed a new program that can analyze more detailed leaf motions. Using this program, we can obtain more detailed information, and therefore can determine the source of dose uncertainties for the dynamic MLC field.

  10. Puzzling with potential: dynamic testing of analogical reasoning in children

    OpenAIRE

    Stevenson, Claire Elisabeth

    2012-01-01

    Assessment procedures are frequent in children's school careers; however, measuring potential for learning has remained a puzzle. Dynamic testing is a method to assess cognitive potential that includes training in the assessment process. The goal of this thesis project was to develop a new dynamic test of analogical reasoning for school children. The main aims were to (1) investigate factors that influence children’s differences in performance and change during dynamic testing and (2) examine...

  11. The use of MRI apparent diffusion coefficient (ADC) in monitoring the development of brain infarction

    International Nuclear Information System (INIS)

    Shen, Jian-Min; Xia, Xian-Wu; Kang, Wu-Gen; Yuan, Jian-Jun; Sheng, Liang

    2011-01-01

    To study the rules that apparent diffusion coefficient (ADC) changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions) were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC) values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as 'pseudonormal' values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P < 0.01). The ADC values and the rADC values in hyperacute and acute lesions had gradient signs that these lesions increased from the center to the periphery. The ADC values and the rADC values in subacute lesions had adverse gradient signs that these lesions decreased from the center to the periphery. The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction

  12. A single-channel 10-bit 160 MS/s SAR ADC in 65 nm CMOS

    Science.gov (United States)

    Yuxiao, Lu; Lu, Sun; Zhe, Li; Jianjun, Zhou

    2014-04-01

    This paper demonstrates a single-channel 10-bit 160 MS/s successive-approximation-register (SAR) analog-to-digital converter (ADC) in 65 nm CMOS process with a 1.2 V supply voltage. To achieve high speed, a new window-opening logic based on the asynchronous SAR algorithm is proposed to minimize the logic delay, and a partial set-and-down DAC with binary redundancy bits is presented to reduce the dynamic comparator offset and accelerate the DAC settling. Besides, a new bootstrapped switch with a pre-charge phase is adopted in the track and hold circuits to increase speed and reduce area. The presented ADC achieves 52.9 dB signal-to-noise distortion ratio and 65 dB spurious-free dynamic range measured with a 30 MHz input signal at 160 MHz clock. The power consumption is 9.5 mW and a core die area of 250 × 200 μm2 is occupied.

  13. Design and characterization of a 12-bit 10MS/s 10mW pipelined SAR ADC for CZT-based hard X-ray imager

    Science.gov (United States)

    Xue, F.; Gao, W.; Duan, Y.; Zheng, R.; Hu, Y.

    2018-02-01

    This paper presents a 12-bit pipelined successive approximation register (SAR) ADC for CZT-based hard X-ray Imager. The proposed ADC is comprised of a first-stage 6-bit SAR-based Multiplying Digital Analog Converter (MDAC) and a second-stage 8-bit SAR ADC. A novel MDAC architecture using Vcm-based Switching method is employed to maximize the energy efficiency and improve the linearity of the ADC. Moreover, the unit-capacitor array instead of the binary-weighted capacitor array is adopted to improve the conversion speed and linearity of the ADC in the first-stage MDAC. In addition, a new layout design method for the binary-weighted capacitor array is proposed to reduce the capacitor mismatches and make the routing become easier and less-time-consuming. Finally, several radiation-hardened-by-design technologies are adopted in the layout design against space radiation effects. The prototype chip was fabricated in 0.18 μm mixed-signal 1.8V/3.3V process and operated at 1.8 V supply. The chip occupies a core area of only 0.58 mm2. The proposed pipelined SAR ADC achieves a peak signal-to-noise-and-distortion ratio (SNDR) of 66.7 dB and a peak spurious-free dynamic range (SFDR) of 78.6 dB at 10 MS/s sampling rate and consumes 10 mW. The figure of merit (FOM) of the proposed ADC is 0.56 pJ/conversion-step.

  14. The use of DWI to assess spleen and liver quantitative ADC changes in the detection of liver fibrosis stages in chronic viral hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Cece, Hasan, E-mail: hasan_cece@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Ercan, Abdulbasit, E-mail: abdulbasitercan@hotmail.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Yıldız, Sema, E-mail: drsemayildiz@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Karakas, Ekrem, E-mail: karakasekrem@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Karakas, Omer, E-mail: dromerkarakas@hotmail.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Boyacı, Fatıma Nurefsan, E-mail: drnurefsan@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Aydogan, Timucin, E-mail: drtaydogan@yahoo.com.tr [Harran University, Faculty of Medicine, Department of Gastroenterology, Sanliurfa (Turkey); Karakas, Emel Yigit, E-mail: e.ygtkarakas@yahoo.com.tr [Sanliurfa Training and Research Hospital, Department of İnternal Medicine, Sanliurfa (Turkey); Cullu, Nesat, E-mail: nesatcullu77@gmail.com [Muğla Sıtkı Koçman University, Faculty of Medicine, Department of Radiology, Mugla (Turkey); Ulas, Turgay, E-mail: turgayulas@yahoo.com [Harran University, Faculty of Medicine, Department of İnternal Medicine, Sanliurfa (Turkey)

    2013-08-15

    This study aimed to evaluate the changes in spleen and liver diffusion-weighted magnetic resonance imaging (DWI) in chronic viral hepatitis patients. The study comprised 47 patients and 30 healthy volunteers. DWIs were obtained. Apparent Diffusion Coefficient (ADC) measurements were made by transferring the images to the workstation. The measurements of value b 1000 were made from a total of five points of the liver and three points of the spleen. Liver biopsy was performed on the 47 patients. The fibrosis stages of the patients were defined according to the METAVIR scoring system. Student's t-test was used in the comparison of mean ages, liver and spleen ADC values between the patient and the control group. Kruskal–Wallis followed by Mann–Whitney U Test with Bonferroni adjustment was performed in the comparison of mean ADC values of the patients at different stages and the control group. A statistically significant difference was determined between the patient and control group in respect of liver and spleen mean ADC values (P < 0.05). F3 group showed a significant difference compared to control and F1 and F4 group showed a significant difference compared to control, F1, F2 and F3 group in terms of the mean liver ADC value (P < 0.01). F3 and F4 group showed a significant difference compared to control and F1 group in terms of the mean spleen ADC value (P < 0.01). As a result we believe that the measurement of liver and spleen ADC values may be an indicator in the determination of the level of fibrosis.

  15. Inhibition of Megakaryocyte Differentiation by Antibody-Drug Conjugates (ADCs) is Mediated by Macropinocytosis: Implications for ADC-induced Thrombocytopenia.

    Science.gov (United States)

    Zhao, Hui; Gulesserian, Sara; Ganesan, Sathish Kumar; Ou, Jimmy; Morrison, Karen; Zeng, Zhilan; Robles, Veronica; Snyder, Josh; Do, Lisa; Aviña, Hector; Karki, Sher; Stover, David R; Doñate, Fernando

    2017-09-01

    Thrombocytopenia is a common adverse event in cancer patients treated with antibody-drug conjugates (ADC), including AGS-16C3F, an ADC targeting ENPP3 (ectonucleotide pyrophosphatase/phosphodiesterase-3) and trastuzumab emtansine (T-DM1). This study aims to elucidate the mechanism of action of ADC-induced thrombocytopenia. ENPP3 expression in platelets and megakaryocytes (MK) was investigated and shown to be negative. The direct effect of AGS-16C3F on platelets was evaluated using platelet rich plasma following the expression of platelet activation markers. Effects of AGS-16C3F, T-DM1, and control ADCs on maturing megakaryocytes were evaluated in an in vitro system in which human hematopoietic stem cells (HSC) were differentiated into MKs. AGS-16C3F, like T-DM1, did not affect platelets directly, but inhibited MK differentiation by the activity of Cys-mcMMAF, its active metabolite. FcγRIIA did not appear to play an important role in ADC cytotoxicity to differentiating MKs. AGS-16C3F, cytotoxic to MKs, did not bind to FcγRIIA on MKs. Blocking the interaction of T-DM1 with FcγRIIA did not prevent the inhibition of MK differentiation and IgG1-mcMMAF was not as cytotoxic to MKs despite binding to FcγRIIA. Several lines of evidence suggest that internalization of AGS-16C3F into MKs is mediated by macropinocytosis. Macropinocytosis activity of differentiating HSCs correlated with cell sensitivity to AGS-16C3F. AGS-16C3F was colocalized with a macropinocytosis marker, dextran-Texas Red in differentiating MKs. Ethyl isopropyl amiloride (EIPA), a macropinocytosis inhibitor, blocked internalization of dextran-Texas Red and AGS-16C3F. These data support the notion that inhibition of MK differentiation via macropinocytosis-mediated internalization plays a role in ADC-induced thrombocytopenia. Mol Cancer Ther; 16(9); 1877-86. ©2017 AACR See related article by Zhao et al., p. 1866 . ©2017 American Association for Cancer Research.

  16. Patterns of shift in ADC distributions in abdominal tumours during chemotherapy - feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Kirsteen; Olsen, Oeystein E. [Great Ormond Street Hospital for Children NHS Trust, Radiology Department, London (United Kingdom); Sebire, Neil J. [Great Ormond Street Hospital for Children NHS Trust, Histopathology Department, London (United Kingdom); Anderson, John [Great Ormond Street Hospital for Children NHS Trust, Oncology Department, London (United Kingdom)

    2011-01-15

    Apparent diffusion coefficient (ADC) relates to tissue cellularity, and change in ADC during chemotherapy may be a promising tool for assessing oncological response. To investigate the feasibility of measuring changes in ADC distribution in solid abdominal and pelvic paediatric tumours during chemotherapy, and to assess patterns of change. Consecutive children were included in a prospective observational study. ADC maps were calculated at presentation and following chemotherapy from a diffusion-sensitised sequence. ADC distribution in the whole tumour, excluding areas of low or absent gadolinium-enhancement, was investigated. Change during chemotherapy was assessed for each patient individually. Histopathological slices from the resected specimens were reviewed. There were seven children (nine tumours) included in the study. ADC in all except one deviated from a normal distribution. All tumours changed their ADC distribution during chemotherapy. Median ADC increased in all upper abdominal tumours, but more in tumours with histopathologically good or marked response to chemotherapy. Seven out of nine tumours attained a wider ADC distribution, the remaining two showed little chemotherapy response. ADC distribution changes during chemotherapy in childhood abdominal tumours are measurable. Distinct patterns of shift can be observed and ADC change is therefore promising as a noninvasive biomarker for therapy response. (orig.)

  17. SEMICONDUCTOR INTEGRATED CIRCUITS: A high-performance, low-power σ Δ ADC for digital audio applications

    Science.gov (United States)

    Hao, Luo; Yan, Han; Cheung, Ray C. C.; Xiaoxia, Han; Shaoyu, Ma; Peng, Ying; Dazhong, Zhu

    2010-05-01

    A high-performance low-power σ Δ analog-to-digital converter (ADC) for digital audio applications is described. It consists of a 2-1 cascaded σ Δ modulator and a decimation filter. Various design optimizations are implemented in the system design, circuit implementation and layout design, including a high-overload-level coefficient-optimized modulator architecture, a power-efficient class A/AB operational transconductance amplifier, as well as a multi-stage decimation filter conserving area and power consumption. The ADC is implemented in the SMIC 0.18-μm CMOS mixed-signal process. The experimental chip achieves a peak signal-to-noise-plus-distortion ratio of 90 dB and a dynamic range of 94 dB over 22.05-kHz audio band and occupies 2.1 mm2, which dissipates only 2.1 mA quiescent current in the analog circuits.

  18. Development of dynamic Bayesian models for web application test management

    Science.gov (United States)

    Azarnova, T. V.; Polukhin, P. V.; Bondarenko, Yu V.; Kashirina, I. L.

    2018-03-01

    The mathematical apparatus of dynamic Bayesian networks is an effective and technically proven tool that can be used to model complex stochastic dynamic processes. According to the results of the research, mathematical models and methods of dynamic Bayesian networks provide a high coverage of stochastic tasks associated with error testing in multiuser software products operated in a dynamically changing environment. Formalized representation of the discrete test process as a dynamic Bayesian model allows us to organize the logical connection between individual test assets for multiple time slices. This approach gives an opportunity to present testing as a discrete process with set structural components responsible for the generation of test assets. Dynamic Bayesian network-based models allow us to combine in one management area individual units and testing components with different functionalities and a direct influence on each other in the process of comprehensive testing of various groups of computer bugs. The application of the proposed models provides an opportunity to use a consistent approach to formalize test principles and procedures, methods used to treat situational error signs, and methods used to produce analytical conclusions based on test results.

  19. An 8 bit 1 MS/s SAR ADC with 7.72-ENOB

    Science.gov (United States)

    Duan, Jihai; Zhu, Zhiyong; Deng, Jinli; Xu, Weilin

    2017-08-01

    This paper presents a low power 8-bit 1 MS/s SAR ADC with 7.72-bit ENOB. Without an op-amp, an improved segmented capacitor DAC is proposed to reduce the capacitance and the chip area. A dynamic latch comparator with output offset voltage storage technology is used to improve the precision. Adding an extra positive feedback in the latch is to increase the speed. What is more, two pairs of CMOS switches are utilized to eliminate the kickback noise introduced by the latch. The proposed SAR ADC was fabricated in SMIC 0.18 {{μ }}{{m}} CMOS technology. The measured results show that this design achieves an SFDR of 61.8 dB and an ENOB of 7.72 bits, and it consumes 67.5 μW with the FOM of 312 fJ/conversion-step at 1 MS/s sample under 1.8 V power supply. Project supported by the National Natural Science Foundation of China (Nos. 61161003, 61264001, 61166004) and the Guangxi Key Laboratory of Precision Navigation Technology and Application Foundation (No. DH201501).

  20. Recent developments in dynamic testing of materials

    Directory of Open Access Journals (Sweden)

    Seidt J.D.

    2012-08-01

    Full Text Available Three new testing configurations that have been developed since the last DYMAT conference in 2009 are presented. The first is high strain rate testing of Kevlar cloth and Kevlar yarn in a tensile Split Hopkinson Bar (SHB apparatus. The Kevlar cloth/yarn is attached to the bars by specially designed adaptors that keep the impedance constant. In addition to determining the specimen’s stress and strain from the recorded waves in the bars the deformations are also measured with Digital Image Correlation (DIC. The second testing configuration is a high strain rate shear test for sheet metal. The experiment is done by using a flat notched specimen in a tensile SHB apparatus. The shear strain is measured using DIC within the notch and on the boundary. The third development is a compression apparatus for testing at intermediate strain rates ranging from 20 s−1 to 200 s−1. The apparatus is a combination of a hydraulic actuator and a compression SHB. The stress in the specimen is determined from the stress wave in a very long transmitter bar and the strain and strain rate is determined by using DIC. The results show clean stress strain curves (no ringing.

  1. Making System Dynamics Cool IV : Teaching & Testing with Cases & Quizzes

    NARCIS (Netherlands)

    Pruyt, E.

    2012-01-01

    This follow-up paper presents cases and multiple choice questions for teaching and testing System Dynamics modeling. These cases and multiple choice questions were developed and used between January 2012 and April 2012 a large System Dynamics course (250+ 2nd year BSc and 40+ MSc students per year)

  2. Making System Dynamics Cool? Using Hot Testing & Teaching Cases

    NARCIS (Netherlands)

    Pruyt, E.

    2009-01-01

    This paper deals with the use of ‘hot’ real-world cases for both testing and teaching purposes such as in the Introductory System Dynamics course at Delft University of Technology in the Netherlands. The paper starts with a brief overview of the System Dynamics curriculum. Then the problem-oriented

  3. Making System Dynamics Cool III : New Hot Teaching & Testing Cases

    NARCIS (Netherlands)

    Pruyt, E.

    2011-01-01

    This follow-up paper presents seven actual cases for testing and teaching System Dynamics developed and used between January 2010 and January 2011 for one of the largest System Dynamics courses (250+ students per year) at Delft University of Technology in the Netherlands. The cases presented in this

  4. Puzzling with potential : dynamic testing of analogical reasoning in children

    NARCIS (Netherlands)

    Stevenson, Claire Elisabeth

    2012-01-01

    Assessment procedures are frequent in children's school careers; however, measuring potential for learning has remained a puzzle. Dynamic testing is a method to assess cognitive potential that includes training in the assessment process. The goal of this thesis project was to develop a new dynamic

  5. Dynamic Mechanical Testing Techniques for Cortical and Cancellous Bone

    Science.gov (United States)

    Cloete, Trevor

    2017-06-01

    Bone fracture typically occurs as an impact loading event (sporting accidents, vehicle collisions), the simulation of which requires in-depth understanding of dynamic bone behavior. Bone is a natural composite material with a complex multi length-scale hierarchical microstructure. At a macroscopic level, it is classified into hard/compact cortical bone and soft/spongy cancellous (trabecular) bone, though both are low-impedance materials relative to steels. Cortical bone is predominant in long bones, while in complex bone geometries (joints, flat bones) a cancellous bone core supports a thin cortical shell. Bone has primarily been studied at quasi-static strain rates (ɛ˙ failure, with interrupted quasi-static tests revealing a strong microstructure dependence. However, bone specimens are typically destroyed during dynamic tests, leading to a lack of dynamic microstructural damage investigations. In this paper, a short overview of dynamic bone testing is presented to give context to the challenges of testing low impedance, strain-rate dependent, non-linear, visco-elastic-brittle materials. Recent state-of-the-art experimental developments in dynamic bone testing are reviewed, with emphasis on pulse shaping, momentum trapping and ISR testing. These techniques allow for dynamic bone testing at small strains and near-constant strain rates with intact specimen recovery. The results are compared to those obtained with varying strain rate tests. Interrupted dynamic test results with microstructural analysis of the recovered specimens are presented and discussed. The paper concludes with a discussion of the experimental and modeling challenges that lie ahead in the field of dynamic bone behavior. The financial assistance of the National Research Foundation and the University of Cape Town towards this research is hereby acknowledged. Opinions expressed and conclusions arrived at are those of the author alone.

  6. THE DYNAMIC BEHAVIOUR OF THE INSTRUMENTED CHARPY TEST

    OpenAIRE

    Mines, R.; Ruiz, C.

    1985-01-01

    The dynamic characteristics of the Charpy test have been studied by means of a Hopkinson bar apparatus and photoelasticity. It is found that this technique permits a clear evaluation of the test results, and is preferable to the standard instrumented pendulum test.

  7. Dynamic Testing of Buses and their Components

    Directory of Open Access Journals (Sweden)

    Záruba Petr

    2017-06-01

    Full Text Available The article gives an overview of a virtual simulation method under ECE Regulation No. R66 - bus rollover. The first part of the article introduces the process of virtual simulations in terms of homologation. The conclusion is focused on the correlation of physical tests with virtual simulations.

  8. Dynamic Hybrid Component Test for Mission-Critical Distributed Systems

    National Research Council Canada - National Science Library

    Park, Joon

    2007-01-01

    The objective of this effort was to provide dynamic and hybrid survivability mechanisms that test a downloaded component in runtime in the current computing environment by considering N-category, N...

  9. 14 CFR 23.726 - Ground load dynamic tests.

    Science.gov (United States)

    2010-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Landing Gear § 23.726 Ground load dynamic tests. (a) If compliance with the ground load requirements of...

  10. Two-Step Single Slope/SAR ADC with Error Correction for CMOS Image Sensor

    Directory of Open Access Journals (Sweden)

    Fang Tang

    2014-01-01

    Full Text Available Conventional two-step ADC for CMOS image sensor requires full resolution noise performance in the first stage single slope ADC, leading to high power consumption and large chip area. This paper presents an 11-bit two-step single slope/successive approximation register (SAR ADC scheme for CMOS image sensor applications. The first stage single slope ADC generates a 3-bit data and 1 redundant bit. The redundant bit is combined with the following 8-bit SAR ADC output code using a proposed error correction algorithm. Instead of requiring full resolution noise performance, the first stage single slope circuit of the proposed ADC can tolerate up to 3.125% quantization noise. With the proposed error correction mechanism, the power consumption and chip area of the single slope ADC are significantly reduced. The prototype ADC is fabricated using 0.18 μm CMOS technology. The chip area of the proposed ADC is 7 μm × 500 μm. The measurement results show that the energy efficiency figure-of-merit (FOM of the proposed ADC core is only 125 pJ/sample under 1.4 V power supply and the chip area efficiency is 84 k μm2·cycles/sample.

  11. Dynamic tests on metallic impact limiters

    International Nuclear Information System (INIS)

    Sagartz, M.J.

    1978-01-01

    Three different types of metallic impact limiters were tested; plain fins, laterally stiffened fins and tubes whose axes were aligned with the direction of impact. All specimens were made of 304 stainless steel and were annealed before testing. A heavy steel drop table of variable mass and moving at about 13.4 m/s (44 ft/s) was used to impact the specimens which were mounted on a stationary base. Impact velocity, drop table acceleration vs. time and force vs. time were measured on each test and were used to calculate the energy absorbed by the impact limiters. Results showed that the peak stress that a plain fin can transmit to the cask body can be several times the static yield stress of the fin. Also as buckling proceeds the load in a plain fin drops significantly and the rate at which it absorbs energy falls off dramatically, making the fin a rather inefficient energy absorber overall. The laterally stiffened fin and the cylinders did not exhibit this rapid decrease in load-carrying capacity with deformation and hence were able to absorb relatively more energy per unit volume of material

  12. Comparison of performance of analog-to-digital converters (ADC) for pulse height analyzers

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1981-01-01

    In the recent ADCs for pulse height analyzers (PHA), Wilkinson type is a leading one, and those with 50 to 200 MHz clock frequency and 8K channel are mostly on the market. The comparison of the performance of ADCs was conducted under the condition of using these multi-channel PHAs as γ-ray spectrometers. The following three ADCs were compared: ADC incorporated in CANBERRA 8100 MCA, and CANBERRA 8060 ADCs used as the ADCs for 1st and 2nd GAMA systems. In this case, the conversion gains of these ADCs were set at 4K because the memory of 8100 MCA was 4K, and the GAMA systems were also mostly operated at 4K. In this paper, report is made on the measurements of dead time, the change of γ peaks immediately after the power was turned on, the temperature dependence of ADCs the long term stability of ADCs, derivative non-linearity, and integration non-linearity. The dead time of the ADC of 8100 CMA was shorter in the range up to 1000 channels. The temperature dependence was -0.017%/deg C in 8100 MCA, and -0.061 and -0.072%/deg C in GAMA. The long term stability was -0.02%/14 hr in 8100 MCA, and -0.027%/14 hr in 8060 of 1st GAMA. The derivative non-linearity was 0.45% in 8100 MCA, 0.67% in 8060 of 1st GAMA, and the integration non-linearity was 0.075% for 8100 MCA, and 0.085 - 0.1% in 8060 ADCs. Also, the change of γ peaks immediately after the power was turned on for 8100 ADC was better than that of 8060 ADC. (Wakatsuki, Y.)

  13. Application of Σ-ΔADC in fluorescence measurement

    International Nuclear Information System (INIS)

    Hao Yan; Chen Ziyu; Shen Ji

    2011-01-01

    It introduces the measurement system of fluorescence intensity, the Σ-ΔADC used as its core components. The system consisted of ADS1255, microcontrollers LPC2368 devices, etc. LPC2368 is used as the control, data process and communication interface. Diagram of the system is given. The linear response experiments, frequency response experiments, measurement accuracy experiments and long-time stability experiments were carried out. Experiments show that the system reaches a good linear response, and the measurement accuracy reaches up to 0.01%. (authors)

  14. Technology Scaling Impact on Embedded ADC Design for Telecom Receivers

    DEFF Research Database (Denmark)

    Nielsen, Jannik Hammel; Andreani, Pietro; Malcovati, Piero

    2005-01-01

    This paper is concerned with the impact of technology scaling on the choice of A/D converters in telecom receivers. It is shown that the trend of diminishing feature size, together with better matching of passive components, allows the use of A/D topologies traditionally confined to low......-frequency, medium-resolution applications. The design of a 10 bit 20 MS/s ADC using the successive approximation algorithm is presented in order to validate the presented concepts. By using a deep-submicron technology, the speed of the chosen architecture is pushed to meet the desired output rate....

  15. Magnetic test of chiral dynamics in QCD

    Energy Technology Data Exchange (ETDEWEB)

    Simonov, Yu.A. [Institute of Theoretical and Experimental Physics,117118, Moscow, B. Cheremushkinskaya 25 (Russian Federation)

    2014-01-22

    Strong magnetic fields in the range eB≫m{sub π}{sup 2} effectively probe internal quark structure of chiral mesons and test basic parameters of the chiral theory, such as 〈q-barq〉,f{sub π}. We argue on general grounds that 〈q-barq〉 should grow linearly with eB when charged quark degrees of freedom come into play. To make explicit estimates we extend the previously formulated chiral theory, including quark degrees of freedom, to the case of strong magnetic fields and show that the quark condensate |〈q-barq〉|{sub u,d} grows quadratically with eB for eB<0.2 GeV{sup 2} and linearly for higher field values. These results agree quantitatively with recent lattice data and differ from χPT predictions.

  16. TRIGA reactor dynamics: Frequency response tests

    International Nuclear Information System (INIS)

    Firat, Coskun; Geckinli, Melih

    2008-01-01

    In this work, the results of frequency response tests conducted on ITU TRIGA Reactor are presented. To conduct the experiments, a special 'micro control rod' and its submersible stepping-motor drive mechanism was designed and constructed. The experiments cover a frequency range of 0.002 - 2 Hz., and 0.02, 4, 200 kW nominal power levels. Zero-power and at-power reactivity to % power transfer functions are presented as gain, and phase shift vs. frequency diagrams. Low power response is in close agreement with the point reactor zero-power transfer function. Response at 200 kW is studied with the help of a Nyquist diagram, and found to be stable. An elaboration on the main features of the feedback mechanism is also given. Power to reactivity feedback was measured to be just about 1.5 cent / % power change. (authors)

  17. Magnetic test of chiral dynamics in QCD

    International Nuclear Information System (INIS)

    Simonov, Yu.A.

    2014-01-01

    Strong magnetic fields in the range eB≫m π 2 effectively probe internal quark structure of chiral mesons and test basic parameters of the chiral theory, such as 〈q-barq〉,f π . We argue on general grounds that 〈q-barq〉 should grow linearly with eB when charged quark degrees of freedom come into play. To make explicit estimates we extend the previously formulated chiral theory, including quark degrees of freedom, to the case of strong magnetic fields and show that the quark condensate |〈q-barq〉| u,d grows quadratically with eB for eB<0.2 GeV 2 and linearly for higher field values. These results agree quantitatively with recent lattice data and differ from χPT predictions

  18. Fast Imaging Detector Readout Circuits with In-Pixel ADCs for Fourier Transform Imaging Spectrometers

    Science.gov (United States)

    Rider, D.; Blavier, J-F.; Cunningham, T.; Hancock, B.; Key, R.; Pannell, Z.; Sander, S.; Seshadri, S.; Sun, C.; Wrigley, C.

    2011-01-01

    Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.

  19. Design and Implementation of Decimation Filter for 13-bit Sigma-Delta ADC Based on FPGA

    Directory of Open Access Journals (Sweden)

    Khalid Khaleel Mohammed

    2016-10-01

    Full Text Available A 13 bit Sigma-Delta ADC for a signal band of 40K Hz is designed in MATLAB Simulink and then implemented using Xilinx system generator tool.  The first order Sigma-Delta modulator is designed to work at a signal band of 40 KHz at an oversampling ratio (OSR of 256 with a sampling frequency of 20.48 MHz. The proposed decimation filter design is consists of a second order Cascaded Integrator Comb filter (CIC followed by two finite impulse response (FIR filters. This architecture reduces the need for multiplication which is need very large area. This architecture implements a decimation ratio of 256 and allows a maximum resolution of 13  bits in the output of the filter. The decimation filter was designed  and  tested  in  Xilinx  system  generator  tool  which  reduces  the  design  cycle  by  directly generating efficient VHDL code. The results obtained show that the overall Sigma-Delta ADC is able to achieve an ENOB (Effective Number Of Bit of 13.71 bits and SNR of 84.3 dB

  20. Continuous-time ΣΔ ADC with implicit variable gain amplifier for CMOS image sensor.

    Science.gov (United States)

    Tang, Fang; Bermak, Amine; Abbes, Amira; Benammar, Mohieddine Amor

    2014-01-01

    This paper presents a column-parallel continuous-time sigma delta (CTSD) ADC for mega-pixel resolution CMOS image sensor (CIS). The sigma delta modulator is implemented with a 2nd order resistor/capacitor-based loop filter. The first integrator uses a conventional operational transconductance amplifier (OTA), for the concern of a high power noise rejection. The second integrator is realized with a single-ended inverter-based amplifier, instead of a standard OTA. As a result, the power consumption is reduced, without sacrificing the noise performance. Moreover, the variable gain amplifier in the traditional column-parallel read-out circuit is merged into the front-end of the CTSD modulator. By programming the input resistance, the amplitude range of the input current can be tuned with 8 scales, which is equivalent to a traditional 2-bit preamplification function without consuming extra power and chip area. The test chip prototype is fabricated using 0.18 μm CMOS process and the measurement result shows an ADC power consumption lower than 63.5 μW under 1.4 V power supply and 50 MHz clock frequency.

  1. Differentiation of benign and malignant lymph nodes with ADC value on diffusion MR: a Meta-analysis

    International Nuclear Information System (INIS)

    Long Miaomiao; Liu Lihua; Gao Guangfeng; Chen Lihua; Shen Wen; Qi Ji

    2012-01-01

    Objective: To summarize the diagnostic efficacy of ADC value for differentiation of benign and malignant lymph nodes on diffusion MRI with Meta-analysis. Methods: Published papers on differentiation of benign and malignant lymph nodes with ADC value were searched and reviewed. Quality evaluation was performed for the eligible papers before data extraction.Test for heterogeneity was performed first, then appropriate model was selected to calculate the weighted mean difference, sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio,pretest and posttest probability. The potential of ADC value for differentiation of benign and malignant lymph nodes was assessed qualitatively and quantitatively. Results: Fifteen papers including 735 cases and 1963 lymph nodes were selected. According to Meta-regression analysis, subgroup analysis and robust analysis, two studies with benign lymph nodes in patients with benign lesion and one study using chemical shift saturation technique were excluded because of their impact on the robustness of the pooled results. The weighted mean difference (WMD) between malignant and benign lymph nodes was -0.355 × 10 -3 mm 2 /s [95% confidence interval (CI):-0.423 ×10-3- -0.288 × 10 -3 mm 2 /s]. Although the cutoff of ADC value for differentiation in each study was different, the diagnostic efficacy was stable, the pooled sensitivity,specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under summarized receiver operator's curve were 0.87 (95% CI: 0.79-0.92), 0.87 (95% CI: 0.82-0.90), 6.5 (95% CI: 4.7-9.2), 0.15 (95% CI: 0.09-0.25), 43 (95% CI: 21-87), 0.93 (95% CI: 0.90-0.95). The posttest malignancy probability of benign lymph node indicated by ADC was 6%, while that of malignant lymph node was 72%. Conclusion: The ADC value can be used to differentiate benign and malignant lymph nodes with good sensitivity and specificity noninvasively. (authors)

  2. Distinguish Dynamic Basic Blocks by Structural Statistical Testing

    DEFF Research Database (Denmark)

    Petit, Matthieu; Gotlieb, Arnaud

    selection of test data over the subdomain associated with these paths. Baudry et al. present a testing for-diagnosis method where the essential notion of Dynamic Basic Block was identified to be strongly correlated to the effectiveness of fault-localization technique. We show that generating a sequence...

  3. PASLINK and dynamic outdoor testing of building components

    NARCIS (Netherlands)

    Baker, P.H.; Dijk, H.A.L. van

    2008-01-01

    The PASLINK test facilities and analysis procedures aim to obtain the thermal and solar characteristics of building components under real dynamic outdoor conditions. Both the analysis and the test methodology have evolved since the start of the PASSYS Project in 1985. A programme of upgrading the

  4. Power and area efficient 4-bit column-level ADC in a CMOS pixel sensor for the ILD vertex detector

    International Nuclear Information System (INIS)

    Zhang, L; Morel, F; Hu-Guo, Ch; Hu, Y

    2013-01-01

    A 48 × 64 pixels prototype CMOS pixel sensor (CPS) integrated with 4-bit column-level, self triggered ADCs for the outer layers of the ILD vertex detector (VTX) was developed and fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. The pixel concept combines in-pixel amplification with a correlated double sampling (CDS) operation. The ADCs accommodating the pixel read out in a rolling shutter mode complete the conversion by performing a multi-bit/step approximation. The design was optimised for power saving at sampling frequency. The prototype sensor is currently at the stage of being started testing and evaluation. So what is described is based on post simulation results rather than test data. This 4-bit ADC dissipates, at a 3-V supply and 6.25-MS/s sampling rate, 486 μW in its inactive mode, which is by far the most frequent. This value rises to 714 μW in case of the active mode. Its footprint amounts to 35 × 545 μm 2 .

  5. A fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    International Nuclear Information System (INIS)

    Liebl, W.; Franz, N.; Ziegler, G.

    1982-01-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed. (orig.)

  6. Predictive value of ADC mapping in discriminating probably benign and suspicious breast lesions

    Directory of Open Access Journals (Sweden)

    Mohamed Hamed Abowarda

    2015-06-01

    Conclusion: Including the ADC diffusion coefficient in the diagnostic work up of patients with indeterminate breast lesions can help in the differentiation between benign and malignant breast lesions.

  7. A high speed, selective multi-ADC to computer data transfer interface, for nuclear physics experiments

    International Nuclear Information System (INIS)

    Arctaedius, T.; Ekstroem, R.E.

    1986-08-01

    A link connecting up to fifteen Analog to Digital Converters with a computer, through a Direct Memory Access interface, is described. The interface decides which of the connected ADC:s that participate in an event, and transfers the output-data from these to the computer, accompanied with a 2-byte word identifying the participating ADC:s. This data format can be recorded on tape without further transformations, and is easy to unfold at the off-line analysis. Data transfer is accomplished in less than a few microseconds, which is made possible by the use of high speed TTL circuits. (authors)

  8. Design and Simulation of 1-bit Sigma Delta ADC in 0.18um CMOS Technology

    OpenAIRE

    Jaydip H. Chaudhari

    2013-01-01

    This paper presents the design of a first order single bit Sigma-Delta ADC which is realized using CMOS technology. In this paper, a first Order Sigma-Delta ADC is implemented in a standard 0.18um CMOS technology. The Design and Simulation of the Modulator is done using Mentor Graphics Tool. First order single bit Sigma Delta ADC Modulator is implemented using ±1.8 power supply and simulation results are plotted using Mentor Graphics Tool. This paper firstly elaborate about ADC types and Clas...

  9. Development of an ADC Radiation Tolerance Characterization System for the Upgrade of the ATLAS LAr Calorimeter

    CERN Document Server

    INSPIRE-00445642; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge

    2016-01-01

    ATLAS LAr calorimeter will perform its Phase-I upgrade during the long shut down (LS2) in 2018, a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multichannel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for LTDB. In order to evaluate the radiation tolerance of these back up commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, which has ADC driver and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as DAQ board. The data from ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed wit...

  10. Can pretreatment ADC values predict recurrence of bladder cancer after transurethral resection?

    Energy Technology Data Exchange (ETDEWEB)

    Funatsu, Hiroyuki, E-mail: hirofunatsu999@hotmail.com [Division of Diagnostic Imaging, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Imamura, Akihiro; Takano, Hideyuki [Division of Diagnostic Imaging, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Ueda, Takeshi [Division of Urology, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Uno, Takashi [Department of Radiology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuou-ku, Chiba 260-8670 (Japan)

    2012-11-15

    Objective: The aim of this retrospective study was to investigate the association between the pretreatment apparent diffusion coefficient (ADC) value and recurrence of bladder cancer after transurethral resection. Methods: Patients with superficial bladder cancer were identified. Mean ADC values of the tumors were compared between patients with and without recurrence following trans-urethral resection. A receiver-operator characteristic curve was used for determining the optimal cutoff ADC value. Univariate and multivariate analyses were used to determine the effect of ADC values and other factors. Results: With a mean follow-up period of 25 months, bladder cancer recurred in 14 of 44 patients (32%). The mean ADC value of tumors in patients with recurrence was lower than in those without recurrence (1.08 mm{sup 2}/s vs. 1.28 Multiplication-Sign 10{sup -3} mm{sup 2}/s; p = 0.003). The optimal cutoff ADC value for predicting recurrence was determined to be 1.12 Multiplication-Sign 10{sup -3} mm{sup 2}/s. A modest and significant negative correlation was observed between the ADC values and tumor size (r = -0.436, p = 0.008). After adjustment for size and risk groups, an ADC value equal to or less than the optimal cutoff remained a significant predictor of recurrence (odds ratio 6.3, 95% CI 1.23-32.2, p = 0.027). Conclusion: Pretreatment ADC values may be an independent predictor of bladder cancer recurrence.

  11. Can pretreatment ADC values predict recurrence of bladder cancer after transurethral resection?

    International Nuclear Information System (INIS)

    Funatsu, Hiroyuki; Imamura, Akihiro; Takano, Hideyuki; Ueda, Takeshi; Uno, Takashi

    2012-01-01

    Objective: The aim of this retrospective study was to investigate the association between the pretreatment apparent diffusion coefficient (ADC) value and recurrence of bladder cancer after transurethral resection. Methods: Patients with superficial bladder cancer were identified. Mean ADC values of the tumors were compared between patients with and without recurrence following trans-urethral resection. A receiver–operator characteristic curve was used for determining the optimal cutoff ADC value. Univariate and multivariate analyses were used to determine the effect of ADC values and other factors. Results: With a mean follow-up period of 25 months, bladder cancer recurred in 14 of 44 patients (32%). The mean ADC value of tumors in patients with recurrence was lower than in those without recurrence (1.08 mm 2 /s vs. 1.28 × 10 −3 mm 2 /s; p = 0.003). The optimal cutoff ADC value for predicting recurrence was determined to be 1.12 × 10 −3 mm 2 /s. A modest and significant negative correlation was observed between the ADC values and tumor size (r = −0.436, p = 0.008). After adjustment for size and risk groups, an ADC value equal to or less than the optimal cutoff remained a significant predictor of recurrence (odds ratio 6.3, 95% CI 1.23–32.2, p = 0.027). Conclusion: Pretreatment ADC values may be an independent predictor of bladder cancer recurrence.

  12. Role of quantitative and dynamic radioactive studies in renal testing

    International Nuclear Information System (INIS)

    Raynaud, C.

    1977-01-01

    Many dynamic and quantitative radioactive tests are at present used in studying renal function. Whether involving dynamic morphological tests such as sequential images, dynamic quantitative tests such as the renogram or quantitative static tests such as radioactive clearances, their effective and original contribution is rather unimportant. Only one provides original data, the Hg renal uptake test but it is generally avoided due to the radiation dose absorbed by the kidney in children. A study of the causes of this lack of effectiveness leads to the observation that such tests are not well adapted to the needs of kidneys specialists. They are for the most part based on replacing a 'cold' indicator by radioactive indicator and the advantages anticipated from using radionuclide are not evident. In fact, they are often cancelled by the shortcomings of external detection. For the future, it seems indispensable to abandon some traditional concepts which lead us to consider that the only exploitable renal function is represented by excretion. The kidney has other functions; one of the most interesting seems to be the function of uptake of heavy metals and toxic substances, a study of which is only possible using radionuclides. A new generation of radioactive tests based on a study of uptake and also on a study of other renal functions may provide dynamic or quantitative data which physician urgently need

  13. X-ray testing for short-time dynamic applications

    International Nuclear Information System (INIS)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried

    2017-01-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  14. An analysis of spacecraft dynamic testing at the vehicle level

    OpenAIRE

    Scott, Alan D.

    1996-01-01

    Approved for public release; distribution is unlimited The US space industry has accumulated a vast amount of expertise in the testing of spacecraft to ensure these vehicles can endure the harsh environments associated with launch and on-orbit operations. Even with this corporate experience, there remains a wide variation in the techniques utilized to test spacecraft during the development and manufacturing process, particularly with regard to spacecraft level dynamics testing. This study ...

  15. Performance evaluation of the analogue front-end and ADC prototypes for the Gotthard-II development

    Science.gov (United States)

    Zhang, J.; Andrä, M.; Barten, R.; Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Fröjdh, E.; Greiffenberg, D.; Lopez-Cuenca, C.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Redford, S.; Ruat, M.; Ruder, C.; Schmitt, B.; Shi, X.; Thattil, D.; Tinti, G.; Turcato, M.; Vetter, S.

    2017-12-01

    Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.

  16. OOK power model based dynamic error testing for smart electricity meter

    Science.gov (United States)

    Wang, Xuewei; Chen, Jingxia; Yuan, Ruiming; Jia, Xiaolu; Zhu, Meng; Jiang, Zhenyu

    2017-02-01

    This paper formulates the dynamic error testing problem for a smart meter, with consideration and investigation of both the testing signal and the dynamic error testing method. To solve the dynamic error testing problems, the paper establishes an on-off-keying (OOK) testing dynamic current model and an OOK testing dynamic load energy (TDLE) model. Then two types of TDLE sequences and three modes of OOK testing dynamic power are proposed. In addition, a novel algorithm, which helps to solve the problem of dynamic electric energy measurement’s traceability, is derived for dynamic errors. Based on the above researches, OOK TDLE sequence generation equipment is developed and a dynamic error testing system is constructed. Using the testing system, five kinds of meters were tested in the three dynamic power modes. The test results show that the dynamic error is closely related to dynamic power mode and the measurement uncertainty is 0.38%.

  17. Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

    Science.gov (United States)

    Winnitoy, Susan

    2012-01-01

    Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic

  18. Testing of tunnel support: dynamic load testing of rock support containment systems (eg wire mesh).

    CSIR Research Space (South Africa)

    Ortlepp, WD

    1997-07-01

    Full Text Available The objective of this project was to determine the performance characteristics of containment elements of tunnel support in common use in South African mines under dynamic loading. The magnitude of the energy levels in this testing had...

  19. Apparent diffusion coefficient values and dynamic contrast enhancement patterns in differentiating seminomas from nonseminomatous testicular neoplasms

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Sylakos, Anastasios; Ntorkou, Alexandra; Stavrou, Sotirios; Astrakas, Loukas G.; Sofikitis, Nikolaos; Argyropoulou, Maria I.

    2015-01-01

    Highlights: • Functional MRI in the characterization of testicular germ cell tumors was assessed. • ADC values proved useful in the characterization of testicular germ cell tumors. • Testicular germ cell tumors had similar enhancement patterns of dynamic MRI. - Abstract: Introduction: The aim of this study is to investigate the role of apparent diffusion coefficient (ADC) values and dynamic contrast enhancement (DCE) patterns in differentiating seminomas from nonseminomatous germ cell tumors (NSGCTs). Materials and methods: The MRI examinations of the scrotum of 26 men with histologically proven testicular GCTs were reviewed. DWI was performed in all patients, using a single shot, multi-slice spin-echo planar diffusion pulse sequence and b-values of 0 and 900 s/mm 2 . Subtraction DCE-MRI was performed in 20 cases using a 3D fast-field echo sequence after gadolinium administration. Time-signal intensity curves were created and semi-quantitative parameters (peak enhancement, time to peak, wash-in and wash-out rate) were calculated. The Student's t-test was used to compare the mean values of ADC, peak enhancement, time to peak, wash-in and wash-out rate between seminomas and NSGCTs. ROC analysis was also performed. Results: Histopathology disclosed the presence of 15 seminomas and 11 NSGCTs. The mean ± s.d. of ADC values (× 10 −3 mm 2 /s) of seminomas (0.59 ± 0.009) were significantly lower than those of NSGCTs (0.90 ± 0.33) (P = 0.01). The optimal ADC cut-off value was 0.68 × 10 −3 mm 2 /s. No differences between the two groups were observed for peak enhancement (P = 0.18), time to peak (P = 0.63) wash-in rate (P = 0.32) and wash-out rate (P = 0.18). Conclusions: ADC values may be used to preoperatively differentiate seminomas from NSGCTs

  20. Full scale dynamic testing of Kozloduy NPP unit 5 structures

    International Nuclear Information System (INIS)

    Da Rin, E.M.

    1999-01-01

    As described in this report, the Kozloduy NPP western site has been subjected to low level earthquake-like ground shaking - through appropriately devised underground explosions - and the resulting dynamic response of the NPP reactor Unit 5 important structures appropriately measured and digitally recorded. In-situ free-field response was measured concurrently more than 100 m aside the main structures of interest. The collected experimental data provide reference information on the actual dynamic characteristics of the Kozloduy NPPs main structures, as well as give some useful indications on the dynamic soil-structure interaction effects for the case of low level excitation. Performing the present full-scale dynamic structural testing activities took advantage of the experience gained by ISMES during similar tests, lately performed in Italy and abroad (in particular, at the Paks NPP in 1994). The IAEA promoted dynamic testing of the Kozloduy NPP Unit 5 by means of pertinently designed buried explosion-induced ground motions which has provided a large amount of data on the dynamic structural response of its major structures. In the present report, the conducted investigation is described and the acquired digital data presented. A series of preliminary analyses were undertaken for examining in detail the ground excitation levels that were produced by these weak earthquake simulation experiments, as well as for inferring some structural characteristics and behaviour information from the collected data. These analyses ascertained the high quality of the collected digital data. Presumably due to soil-structure dynamic interaction effects, reduced excitation levels were observed at the reactor building foundation raft level with respect to the concurrent free-field ground motions. measured at a 140 m distance from the reactor building centre. Further more detailed and systematic analyses are worthwhile to be performed for extracting more complete information about the

  1. Dynamic tension testing equipment for paperboard and corrugated fiberboard

    Science.gov (United States)

    W. D. Godshall

    1965-01-01

    The objective of this work was to develop a method, the testing equipment, and the instrumentation with which dynamic stress-strain information may be obtained for paperboards and built-up corrugated fiberboards as used in corrugated fiberboard containers. Much information is available on the properties of these materials when subjected to static or low rates of...

  2. Proposta de uma versão brasileira para a escala ADCS-CGIC A Brazilian Portuguese version for the ADCS-CGIC scale

    Directory of Open Access Journals (Sweden)

    Paulo H.F. Bertolucci

    2003-09-01

    Full Text Available Com o crescente volume de pesquisas sobre novas terapias para as demências, em particular a doença de Alzheimer, tornou-se evidente que a avaliação mais tradicional, centrada nas alterações da cognição, não seria suficiente para detectar algumas das alterações significativas que novos tratamentos podem trazer. Deste modo, foram acrescentadas escalas para avaliar alterações do comportamento e da dependência funcional. Ainda assim, restavam mudanças, percebidas pelos familiares, que poderiam não ser captadas por essas escalas. As escalas de impressão clínica de mudança (CIGIC baseiam-se nas informações fornecidas pelo informante, no que é observado durante a consulta, e, se necessário, em breves testes de cognição. Apresentamos a versão de uma escala deste tipo, largamente utilizada, desenvolvida para a doença de Alzheimer (ADCS-CIGIC, que foi obtida pelo método recomendado de tradução, retro-tradução e versão final por consenso.Given increasing research into new therapies for dementia, especially for Alzheimer disease, it has become clear that traditional methods of evaluation, centered on cognition, have proved insufficient. Thus, scales for behavioral disturbances and activities of daily living have been added. Nevertheless, some observations of clinical significant changes, as reported by caregivers, could be overlooked. Clinician's impression of global change scales (CIGIC are based on broader information and may detect more subtle changes. Typically they take into consideration caregiver information, that which is seen by the health professional during the interview, and may also include brief cognitive tests. We present a Brazilian Portuguese version of a widely used scale of this type, specifically designed for Alzheimer disease (ADCS-CGIC, being the result of the recommended method of translation, back-translation and version by panel consensus.

  3. Full scale dynamic testing of Paks nuclear power plant structures

    International Nuclear Information System (INIS)

    Da Rin, E.M.

    1995-01-01

    This report refers to the full-scale dynamic structural testing activities that have been performed in December 1994 at the Paks (H) Nuclear Power Plant, within the framework of: the IAEA Coordinated research Programme 'Benchmark Study for the Seismic Analysis and Testing of WWER-type Nuclear Power Plants, and the nuclear research activities of ENEL-WR/YDN, the Italian National Electricity Board in Rome. The specific objective of the conducted investigation was to obtain valid data on the dynamic behaviour of the plant's major constructions, under normal operating conditions, for enabling an assessment of their actual seismic safety to be made. As described in more detail hereafter, the Paks NPP site has been subjected to low level earthquake like ground shaking, through appropriately devised underground explosions, and the dynamic response of the plant's 1 st reactor unit important structures was appropriately measured and digitally recorded. In-situ free field response was measured concurrently and, moreover, site-specific geophysical and seismological data were simultaneously acquired too. The above-said experimental data is to provide basic information on the geophysical and seismological characteristics of the Paks NPP site, together with useful reference information on the true dynamic characteristics of its main structures and give some indications on the actual dynamic soil-structure interaction effects for the case of low level excitation

  4. Supersonic Flight Dynamics Test 2: Trajectory, Atmosphere, and Aerodynamics Reconstruction

    Science.gov (United States)

    Karlgaard, Christopher D.; O'Farrell, Clara; Ginn, Jason M.; Van Norman, John W.

    2016-01-01

    The Supersonic Flight Dynamics Test is a full-scale flight test of aerodynamic decelerator technologies developed by the Low Density Supersonic Decelerator technology demonstration project. The purpose of the project is to develop and mature aerodynamic decelerator technologies for landing large-mass payloads on the surface of Mars. The technologies include a Supersonic Inflatable Aerodynamic Decelerator and supersonic parachutes. The first Supersonic Flight Dynamics Test occurred on June 28th, 2014 at the Pacific Missile Range Facility. The purpose of this test was to validate the test architecture for future tests. The flight was a success and, in addition, was able to acquire data on the aerodynamic performance of the supersonic inflatable decelerator. The Supersonic Disksail parachute developed a tear during deployment. The second flight test occurred on June 8th, 2015, and incorporated a Supersonic Ringsail parachute which was redesigned based on data from the first flight. Again, the inflatable decelerator functioned as predicted but the parachute was damaged during deployment. This paper describes the instrumentation, analysis techniques, and acquired flight test data utilized to reconstruct the vehicle trajectory, main motor thrust, atmosphere, and aerodynamics.

  5. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values

    International Nuclear Information System (INIS)

    Thoermer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Kahn, Thomas; Busse, Harald; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian

    2012-01-01

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm 2 ) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS = 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. (orig.)

  6. Two-Speed Gearbox Dynamic Simulation Predictions and Test Validation

    Science.gov (United States)

    Lewicki, David G.; DeSmidt, Hans; Smith, Edward C.; Bauman, Steven W.

    2010-01-01

    Dynamic simulations and experimental validation tests were performed on a two-stage, two-speed gearbox as part of the drive system research activities of the NASA Fundamental Aeronautics Subsonics Rotary Wing Project. The gearbox was driven by two electromagnetic motors and had two electromagnetic, multi-disk clutches to control output speed. A dynamic model of the system was created which included a direct current electric motor with proportional-integral-derivative (PID) speed control, a two-speed gearbox with dual electromagnetically actuated clutches, and an eddy current dynamometer. A six degree-of-freedom model of the gearbox accounted for the system torsional dynamics and included gear, clutch, shaft, and load inertias as well as shaft flexibilities and a dry clutch stick-slip friction model. Experimental validation tests were performed on the gearbox in the NASA Glenn gear noise test facility. Gearbox output speed and torque as well as drive motor speed and current were compared to those from the analytical predictions. The experiments correlate very well with the predictions, thus validating the dynamic simulation methodologies.

  7. Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility.

    Science.gov (United States)

    Gerodimos, Vassilis; Karatrantou, Konstantina; Psychou, Dimitra; Vasilopoulou, Theodora; Zafeiridis, Andreas

    2017-03-01

    This study investigated the reliability of static and dynamic handgrip strength endurance using different protocols and indicators for the assessment of strength endurance. Forty young, healthy men and women (age, 18-22 years) performed 2 handgrip strength endurance protocols: a static protocol (sustained submaximal contraction at 50% of maximal voluntary contraction) and a dynamic one (8, 10, and 12 maximal repetitions). The participants executed each protocol twice to assess the test-retest reproducibility. Total work and total time were used as indicators of strength endurance in the static protocol; the strength recorded at each maximal repetition, the percentage change, and fatigue index were used as indicators of strength endurance in the dynamic protocol. The static protocol showed high reliability irrespective of sex and hand for total time and work. The 12-repetition dynamic protocol exhibited moderate-high reliability for repeated maximal repetitions and percentage change; the 8- and 10-repetition protocols demonstrated lower reliability irrespective of sex and hand. The fatigue index was not a reliable indicator for the assessment of dynamic handgrip endurance. Static handgrip endurance can be measured reliably using the total time and total work as indicators of strength endurance. For the evaluation of dynamic handgrip endurance, the 12-repetition protocol is recommended, using the repeated maximal repetitions and percentage change as indicators of strength endurance. Practitioners should consider the static (50% maximal voluntary contraction) and dynamic (12 repeated maximal repetitions) protocols as reliable for the assessment of handgrip strength endurance. The evaluation of static endurance in conjunction with dynamic endurance would provide more complete information about hand function. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Advanced WEC Dynamics & Controls FY16 Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Coe, Ryan Geoffrey [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bacelli, Giorgio [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wilson, David G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Patterson, David Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A model-scale wave tank test was conducted in the interest of improving control systems design of wave energy converters (WECs). The success of most control strategies is based directly upon the availability of a reduced-order model with the ability to capture the dynamics of the system with sufficient accuracy. For this reason, the test described in this report, which is the first in a series of planned tests on WEC controls, focused on system identification (system ID) and model validation.

  9. In vitro establishment of Jacaratia spinosa (Aubl. ADC / Estabelecimento in vitro de Jacaratia spinosa (Aubl. ADC

    Directory of Open Access Journals (Sweden)

    Ricardo Tadeu de Faria

    2009-07-01

    inteiramente casualizado, com 10 ápices por concentração de 6-BA. As avaliações visuais das freqüências de sobrevivência dos ápices e número de brotações laterais foram feitas semanalmente, por 90 dias, sendo os resultados em porcentagem submetidos à análise regressão e ao teste do Quiquadrado para várias proporções a 1% de significância. A porcentagem de descontaminação variou entre 60% e 80%. A curva de regressão sugere que a concentração zero apresentou sobrevivência superior às demais, porém o teste do Qui-quadrado mostra que as freqüências variaram de 41,7% até 58,3%, não havendo diferença estatística entre as concentrações de 6-BA. Não foi observada durante os 90 dias, a emissão de brotações laterais nos explantes, sendo necessários novos estudos com outras concentrações de fitoreguladores.

  10. Changes in ADC Caused by Tensile Loading of Rabbit Achilles Tendon: Evidence for Water Transport

    Science.gov (United States)

    Han, S.; Gemmell, S. J.; Helmer, K. G.; Grigg, P.; Wellen, J. W.; Hoffman, A. H.; Sotak, C. H.

    2000-06-01

    Water diffusion measurements were performed on rabbit Achilles tendons during static tensile loading and tendons in an unloaded state. The apparent diffusion coefficient (ADC) was measured along two directions: parallel and perpendicular to the long axis of the tendon. Tendons were studied after being prepared in two ways: (a) after being stored frozen in phosphate-buffered saline (PBS) and (b) freshly isolated. Statistically significant directional anisotropy was observed in the ADC in all tendons. The ADC was significantly greater in the direction parallel to the long axis of the tendon than in the perpendicular direction. The anisotropy is attributed to the greater restrictions seen by the water molecules in the perpendicular direction and is consistent with the known geometry of the tendon. Storage in PBS caused tendons to swell. This increased the ADC measured along both directions and reduced the anisotropy. The existence of anisotropy in the ADC was not related to the orientation of the specimen in the magnet. The ADC increased along both directions following the application of a 5-N tensile load; the increase was greatest along the perpendicular axis of the tendon. In order to determine whether load-related changes in the ADC reflected changes in interfibrilar spacing, we used electron microscopy to measure load-related changes in fibril spacing. Load-related changes in fiber spacing could not account for the observed changes in the ADC. The increase in ADC caused by loading was attributed to the extrusion of tendon water into a bulk phase along the outside surface of the tendon. In PBS-stored samples, enough fluid was extruded that it could be visualized. The transient response of the ADC to a 5-N tensile load was also studied. The absolute ADC in both directions increased with loading and recovered to baseline upon unloading. The transient changes in ADC, for both loading and unloading, had a mean time constant of approximately 15 min. The magnitude of

  11. Transient rotor dynamic rub phenomena - Theory and test

    Science.gov (United States)

    Kascak, A. F.; Montaque, G.; Palazzolo, A. B.

    1987-01-01

    This paper develops an implicit integration scheme for transient rotor dynamic rub prediction and includes a correlation study with actual test results. A Nordsieck-like numerical integration scheme is applied directly to the second-order equations of motion. The assumption that forces and torques on the rotor are functions of the position and velocity at the point of application and its nearest neighbor is made in order to make the computational time proportional to the number of elements in the rotor dynamics model rather than the cube of the number. The test rig consists of a turbine driven, flexible shaft supported by squeeze film dampers. The blade loss event occurs due to collision of a balance bolt on one of the disks with a high speed plunger. The rotor is seen to spiral outward and contact against a stationary assemblage of seal shoes.

  12. Research on Generating Method of Embedded Software Test Document Based on Dynamic Model

    Science.gov (United States)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying

    2018-03-01

    This paper provides a dynamic model-based test document generation method for embedded software that provides automatic generation of two documents: test requirements specification documentation and configuration item test documentation. This method enables dynamic test requirements to be implemented in dynamic models, enabling dynamic test demand tracking to be easily generated; able to automatically generate standardized, standardized test requirements and test documentation, improved document-related content inconsistency and lack of integrity And other issues, improve the efficiency.

  13. A dynamic point-load test for quantifying rock dynamic strength parameters

    Science.gov (United States)

    Yu, Changyi; Yao, Wei; Xu, Ying; Xia, Kaiwen

    2017-11-01

    The point-load test (PLT) has been widely used in the field and in the laboratory to estimate the strength of rock materials. The PLT is easy and quick to perform and it is suitable for samples with irregular shapes and therefore has found wide applications. The measured point-load strength (PLS) is considered as a strength index and it has been correlated to the rock compressive strength. To address the engineering applications where the loading is dynamic, the PLT is extended to its dynamic version in this study. The dynamic loading is exerted to the rock specimen using a split Hopkinson pressure bar system. Two conical steel platens are attached to the incident bar and transmitted bar, respectively, to apply the point load to the disc specimen. To enable quasi-static analysis, the pulse shaper technique is utilized to achieve the dynamic force balance. The flexibility of the dynamic PLT method is demonstrated by the application to a well-studied granitic rock—Laurentian granite. The correlation between the dynamic PLS and the dynamic strength of the same rock is established.

  14. Electromagnetic induction sensor for dynamic testing of coagulation process.

    Science.gov (United States)

    Wang, Zhe; Yu, Yuanhua; Yu, Zhanjiang; Chen, Qimeng

    2018-03-01

    With the increasing demand for coagulation POCT for patients in the surgery department or the ICU, rapid coagulation testing techniques and methods have drawn widespread attention from scholars and businessmen. This paper proposes the use of electromagnetic induction sensor probe for detection of dynamic process causing changes in the blood viscosity and density before and after coagulation based on the damped vibration principle, in order to evaluate the coagulation status. Utilizing the dynamic principle, the differential equation of vibration system comprising elastic support and electromagnetic induction device is established through sensor dynamic modeling. The structural parameters of elastic support are optimized, and the circular sheet spring is designed. Furthermore, harmonic response analysis and vibration fatigue coupling analysis are performed on the elastic support of the sensor by considering the natural frequency of the system, and the electromagnetic induction sensor testing device is set up. Using the device and coagulation reagent, the standard curve for coagulation POCT is plotted, and the blood sample application in clinical patients is established, which are methodologically compared with the imported POCT coagulation analyzer. The results show that the sensor designed in this paper has a first-order natural frequency of 11.368 Hz, which can withstand 5.295 × 10 2 million times of compressions and rebounds. Its correlation with the results of SONOCLOT analyzer reaches 0.996, and the reproducibility 0.002. The electromagnetic induction coagulation testing sensor designed has good elasticity and anti-fatigue, which can meet the accuracy requirement of clinical detection. This study provides the core technology for developing the electromagnetic induction POCT instrument for dynamic testing of coagulation process.

  15. A 10-bit ratio-independent cyclic ADC with offset canceling for a CMOS image sensor

    Science.gov (United States)

    Kaiming, Nie; Suying, Yao; Jiangtao, Xu; Zhaorui, Jiang

    2014-03-01

    A 10-bit ratio-independent switch-capacitor (SC) cyclic analog-to-digital converter (ADC) with offset canceling for a CMOS image sensor is presented. The proposed ADC completes an N-bit conversion in 1.5N clock cycles with one operational amplifier. Combining ratio-independent and polarity swapping techniques, the conversion characteristic of the proposed cyclic ADC is inherently insensitive both to capacitor ratio and to amplifier offset voltage. Therefore, the circuit can be realized in a small die area and it is suitable to serve as the column-parallel ADC in CMOS image sensors. A prototype ADC is fabricated in 0.18-μm one-poly four-metal CMOS technology. The measured results indicate that the ADC has a signal-to-noise and distortion ratio (SNDR) of 53.6 dB and a DNL of +0:12/-0:14 LSB at a conversion rate of 600 kS/s. The standard deviation of the offset variation of the ADC is reduced from 2.5 LSB to 0.5 LSB. Its power dissipation is 250 μW with a 1.8 V supply, and its area is 0.03 × 0.8 mm2.

  16. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 466-8550 (Japan); Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo [Department of Radiology, First Kamiida General Hospital (Japan)

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean{+-}standard deviation 2.3{+-}1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  17. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishigaki, Takeo; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean±standard deviation 2.3±1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  18. Antibody-Drug Conjugates (ADCs) for Personalized Treatment of Solid Tumors: A Review.

    Science.gov (United States)

    Lambert, John M; Morris, Charles Q

    2017-05-01

    Attaching a cytotoxic "payload" to an antibody to form an antibody-drug conjugate (ADC) provides a mechanism for selective delivery of the cytotoxic agent to cancer cells via the specific binding of the antibody to cancer-selective cell surface molecules. The first ADC to receive marketing authorization was gemtuzumab ozogamicin, which comprises an anti-CD33 antibody conjugated to a highly potent DNA-targeting antibiotic, calicheamicin, approved in 2000 for treating acute myeloid leukemia. It was withdrawn from the US market in 2010 following an unsuccessful confirmatory trial. The development of two classes of highly potent microtubule-disrupting agents, maytansinoids and auristatins, as payloads for ADCs resulted in approval of brentuximab vedotin in 2011 for treating Hodgkin lymphoma and anaplastic large cell lymphoma, and approval of ado-trastuzumab emtansine in 2013 for treating HER2-positive breast cancer. Their success stimulated much research into the ADC approach, with >60 ADCs currently in clinical evaluation, mostly targeting solid tumors. Five ADCs have advanced into pivotal clinical trials for treating various solid tumors-platinum-resistant ovarian cancer, mesothelioma, triple-negative breast cancer, glioblastoma, and small cell lung cancer. The level of target expression is a key parameter in predicting the likelihood of patient benefit for all these ADCs, as well as for the approved compound, ado-trastuzumab emtansine. The development of a patient selection strategy linked to target expression on the tumor is thus critically important for identifying the population appropriate for receiving treatment.

  19. Zn2+ Uptake in Streptococcus pyogenes: Characterization of adcA and lmb Null Mutants.

    Science.gov (United States)

    Tedde, Vittorio; Rosini, Roberto; Galeotti, Cesira L

    2016-01-01

    An effective regulation of metal ion homeostasis is essential for the growth of microorganisms in any environment and in pathogenic bacteria is strongly associated with their ability to invade and colonise their hosts. To gain a better insight into zinc acquisition in Group A Streptococcus (GAS) we characterized null deletion mutants of the adcA and lmb genes of Streptococcus pyogenes strain MGAS5005 encoding the orthologues of AdcA and AdcAII, the two surface lipoproteins with partly redundant roles in zinc homeostasis in Streptococcus pneumoniae. Null adcA and lmb mutants were analysed for their capability to grow in zinc-depleted conditions and were found to be more susceptible to zinc starvation, a phenotype that could be rescued by the addition of Zn2+ ions to the growth medium. Expression of AdcA, Lmb and HtpA, the polyhistidine triad protein encoded by the gene adjacent to lmb, during growth under conditions of limited zinc availability was examined by Western blot analysis in wild type and null mutant strains. In the wild type strain, AdcA was always present with little variation in expression levels between conditions of excess or limited zinc availability. In contrast, Lmb and HtpA were expressed at detectable levels only during growth in the presence of low zinc concentrations or in the null adcA mutant, when expression of lmb is required to compensate for the lack of adcA expression. In the latter case, Lmb and HtpA were overexpressed by several fold, thus indicating that also in GAS AdcA is a zinc-specific importer and, although it shares this function with Lmb, the two substrate-binding proteins do not show fully overlapping roles in zinc homeostasis.

  20. Novel test of modified Newtonian dynamics with gas rich galaxies.

    Science.gov (United States)

    McGaugh, Stacy S

    2011-03-25

    The current cosmological paradigm, the cold dark matter model with a cosmological constant, requires that the mass-energy of the Universe be dominated by invisible components: dark matter and dark energy. An alternative to these dark components is that the law of gravity be modified on the relevant scales. A test of these ideas is provided by the baryonic Tully-Fisher relation (BTFR), an empirical relation between the observed mass of a galaxy and its rotation velocity. Here, I report a test using gas rich galaxies for which both axes of the BTFR can be measured independently of the theories being tested and without the systematic uncertainty in stellar mass that affects the same test with star dominated spirals. The data fall precisely where predicted a priori by the modified Newtonian dynamics. The scatter in the BTFR is attributable entirely to observational uncertainty, consistent with a single effective force law.

  1. Optical Fibres Contactless Sensor for Dynamic Testing of Lightweight Structures

    Directory of Open Access Journals (Sweden)

    L. Bregant

    2008-01-01

    Full Text Available With dynamic testing, engineers describe activities focused on the identification of some properties of vibrating structures. This step requires for the measurements of excitations and responses signals, applying appropriate sensors directly on the test article. These instruments modify the system's mass and stiffness distributions and eventually the eigen-properties of the structure. These errors become unacceptable especially when testing lightweight structures. This paper shows the results of some tests performed on a small compressor with the purpose of identifying the blades’ natural frequencies and modes. It compares the acquisitions performed with standard accelerometers and two different contact-less systems using as exciters either a micro-hammer or a micro inertial shaker. The paper shows how the contact-less sensors provide good quality data and consistent results in the mode identification phase.

  2. ADC measurement of abdominal organs and lesions using parallel imaging technique.

    Science.gov (United States)

    Yoshikawa, Takeshi; Kawamitsu, Hideaki; Mitchell, Donald G; Ohno, Yoshiharu; Ku, Yonson; Seo, Yasushi; Fujii, Masahiko; Sugimura, Kazuro

    2006-12-01

    The purpose of our study was to assess the reliability and usefulness of parallel imaging for apparent diffusion coefficient (ADC) measurement of abdominal organs and lesions. Single-shot spin-echo echo-planar diffusion-weighted MRI (TE = 66, b = 0, 600 s/mm2) was performed in phantom and clinical studies. The b value was set to minimize the effects of perfusion in tissue and to maintain signal-to-noise ratio. Bottle phantoms were scanned with and without parallel imaging and with various parallel imaging factors and at various positions to evaluate the effects of parallel imaging on ADCs. In 200 consecutive clinical patients (122 men and 78 women: mean age, 61.9 years), ADCs were calculated for liver (four segments), spleen, pancreas (head, body, tail), gallbladder, renal parenchyma, and back muscle, and then compared to evaluate the reliability of clinical ADC measurements with parallel imaging. ADCs were also calculated for diffuse diseases and focal lesions (94 malignant and 93 benign) of abdominal organs to evaluate the clinical usefulness of ADC. Location-dependent changes in water ADCs were minimal with parallel imaging factors first of 3, then of 4, and were small except for measurements at the image periphery. Acetone ADCs were saturated at 4.00 x 10(-3) mm2/s. Degraded image quality prevented ADC measurement of the left hepatic lobe and pancreas in 7-18 patients. There was no significant difference among ADCs of four liver segments (1.50 +/- 0.24 [SD] x 10(-3) mm2/s - 1.56 +/- 0.31 x 10(-3) mm2/s) and between ADCs of the right and left kidneys (2.65 +/- 0.30 x 10(-3) mm2/s, 2.59 +/- 0.33 x 10(-3) mm2/s). ADC of the pancreas tail (1.65 +/- 0.37 x 10(-3) mm2/s) was significantly lower than those of the head (1.81 +/- 0.40 x 10(-3) mm2/s) and body (1.81 +/- 0.41 x 10(-3) mm2/s) (p parallel imaging appear to be reliable and useful, and the effect of parallel imaging on calculated values is considered to be minimal.

  3. Platform for dynamic tests: preliminary studies, design and construction

    Directory of Open Access Journals (Sweden)

    J. E. Campuzano

    Full Text Available This paper is about the design and construction of a platform for dynamic tests especially with people jumping, walking, etc. Initially it was tried to find out projects already implemented in platforms and dynamic tests and to study the loads produced by movement of people on slabs and the structural response to these loads. The limits established by different standards have been also studied for these dynamic responses, taking into account the ultimate limit state, as well as the structure in service, since the human body is very sensitive to structural vibrations. Parametric studies were performed considering various configurations of slabs (different spans, thicknesses and conditions of support have been done, looking for a configuration that could have natural frequency close to the frequencies of the human loads. The slab should have dimensions compatible with the available physical space, fundamental frequency below 5 Hz and maximum immediate deflection compatible with the indications of the Brazilian standard NBR6118: 2007. Based on these criteria was chosen a rectangular structure consists of a solid reinforced concrete rectangular slab studded in two opposite edges of steel beams with shear connectors type U. The other two edges are free. The steel beams supporting the slab, in turn, are supported on eight metal profiles (two in each corner of the slab that are supported on two to two short columns of steel profile H. Profiles U in steel are welded to four columns, forming a horizontal frame. Numerical analysis of the dynamic test platform have been performed for free and forced vibration, for obtaining the natural frequencies and corresponding vibration modes, considering the self-weight of the structure and the load that simulates people's weight. After obtaining a structural configuration that fulfilled the stipulated requirements, the design of the slab taking into account the recommendations of the Brazilian standard NBR6118: 2007

  4. Is the quantitative Diffusion-Weighted MR Imaging and ADC mapping with b-values of 50, 400, and 800 sec/mm2 a reliable method for evaluation of meniscal tears in the knee?

    International Nuclear Information System (INIS)

    Aydin, H.; Kizilgoz, V.; Hekimoglu, B.

    2011-01-01

    Background: Our aim was to evaluate the efficacy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping with different b-factors in visualisation of meniscal tears. Material/Methods: Seventy-four patients; 30 males and 44 females, 37 left and 37 right knees with meniscal tears were involved in this study. Eleven of them were lateral meniscal tears and 63 - medial meniscal tears. DWI was obtained by 3D-SE Echo-planar Imaging (EPI) in coronal and sagittal planes. ADC mapping was carried out in coronal planes with b-factors of 50, 400, and 800 sec/mm 2 . The statistical analysis of DWI and ADC mapping results was performed with the use of the Fishers test and the chi-square test. Results: 1. For both menisci and 74 tears: DWI revealed 86% sensitivity and 100% specificity (p=0.149) with a positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.09. ADC mapping with b-value of 400 sec/mm 2 had 78% sensitivity, and 100% specificity, with PPV of 1 and NPV of 0.06 (p=0.230). 2. For the lateral meniscal tears: DWI and ADC mapping with b-value of 800, for the medial meniscal tears: DWI and ADC mapping with b-factor of 400 s/mm 2 revealed higher sensitivity and specificity than other methods. Conclusions: Quantitative DWI and ADC mapping, especially with b-factor of 400 sec/mm 2 , may be an alternative to routine MR imaging sequences for the visualisation of meniscal tears in the knee. (authors)

  5. Using Spare Logic Resources To Create Dynamic Test Points

    Science.gov (United States)

    Katz, Richard; Kleyner, Igor

    2011-01-01

    A technique has been devised to enable creation of a dynamic set of test points in an embedded digital electronic system. As a result, electronics contained in an application specific circuit [e.g., gate array, field programmable gate array (FPGA)] can be internally probed, even when contained in a closed housing during all phases of test. In the present technique, the test points are not fixed and limited to a small number; the number of test points can vastly exceed the number of buffers or pins, resulting in a compact footprint. Test points are selected by means of spare logic resources within the ASIC(s) and/or FPGA(s). A register is programmed with a command, which is used to select the signals that are sent off-chip and out of the housing for monitoring by test engineers and external test equipment. The register can be commanded by any suitable means: for example, it could be commanded through a command port that would normally be used in the operation of the system. In the original application of the technique, commanding of the register is performed via a MIL-STD-1553B communication subsystem.

  6. Dynamic Brazilian Test for Mechanical Characterization of Ceramic Ballistic Protection

    Directory of Open Access Journals (Sweden)

    Martina Scapin

    2017-01-01

    Full Text Available The aim of this work is to identify the tensile strength of alumina (Corbit98, by performing Brazilian tests at different loading rate. In this kind of test, generally used for brittle material in static loading conditions, a cylindrical specimen is diametrically compressed and failure is generated in the middle of the component as a consequence of a positive tensile stress. In this work, this experimental technique was applied also in dynamic loading conditions by using a setup based on the Split Hopkinson Pressure Bar. Due to the properties of the investigated material, among which are high hardness, high compressive strength, and brittle behaviour, some precautions were needed to assure the validity of the tests. Digital Image Correlation techniques were applied for the analysis of high framerate videos.

  7. Low Power 2-Bit ADC Array with Serial Output, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave interferometers for NASA missions such as PATH employ the GeoSTAR instrument, consisting of 600 receivers. Each receiver requires I and Q ADCs...

  8. Low Power 1-Bit ADC Array with Serial Output, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave interferometers for NASA missions such as PATH and SCLP consist of up to 900 receivers. Each receiver requires I and Q ADCs (analog-to-digital converters)...

  9. High Performance ADC for Reconfigurable/Reprogrammable Communication Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will develop a 3X improvement in sampling resolution over current state-of-the art analog-to-digital converter (ADC) technology to support...

  10. A Low Power Rad-Hard ADC for the KID Readout Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposal aims to develop a radiation hardened analog-to-digital converter (ADC) required for the Kinetic Inductance Detector (KID) readout electronics. KIDs are...

  11. Rad-Hard Sigma-Delta 3-channel ADC for Fluxgate Magnetometers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project aims to develop a multi-channel analog to digital converter (ADC) required for a fluxgate magnetometer (EPD) employed on NASA's planetary...

  12. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will design a high-speed, low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital beam forming...

  13. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase 1, Ridgetop Group designed a high-speed, yet low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital...

  14. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will design a high-speed, low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital beam forming...

  15. Very High-Performance Advanced Filter Bank Analog-to-Digital Converter (AFB ADC) Project

    National Research Council Canada - National Science Library

    Velazquez, Scott

    1999-01-01

    ... of the art by using a parallel array of individual commercial off the shelf converters. The significant performance improvements afforded by the Advanced Filter Bank Analog to Digital Converter (AFB ADC...

  16. Design and development of CAMAC 12 bit ADC/DAC dual purpose module

    International Nuclear Information System (INIS)

    Kulkarni, S.G.; Gore, J.A.; Ramlal, V.; Matkar, U.V.; Lokare, R.N.; Yadav, M.L.; Ekambaram, M.; Gupta, A.K.; Datar, V.M.

    2013-01-01

    A dual function CAMAC module is designed for Pelletron Accelerator which can function as 12 bit 8 channels DAC or 12 bit 16 channels ADC. Spartan 2 series of FPGA is used for implementing the CAMAC interface logic as well as logic for ADC/DAC interface. The PCB has both the ADC and DAC mounted but the module can have only one function selected due to wiring constraint. Two different VHDL programs (one for the ADC and other for the DAC) reside on the EEPROM permitting selection of any one as per the functionality required. The module is working as a 12 bit DAC at BARC-TIFR Pelletron Linac Facility, successfully. (author)

  17. 20GSps 6-bit Low-Power Rad-Tolerant ADC, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project aims to develop a 20GSps 6-bit radiation hardened analog to digital converter (ADC) required for microwave radiometers being developed for space...

  18. 20GSps 6-bit Low-Power Rad-Tolerant ADC, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project aims to develop a 20GSps 6-bit ADC required for microwave radiometers being developed for space and airborne earth sensing applications and...

  19. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase 1, Ridgetop Group designed a high-speed, yet low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital...

  20. A 0.9-V switched-opamp-based delta—sigma ADC with dual cycle shift DWA

    Science.gov (United States)

    Jinchen, Zhao; Menglian, Zhao; Xiaobo, Wu; Hanqing, Wang

    2013-06-01

    This paper presents a low-power high-precision switched-opamp(SO)-based delta—sigma (ΔΣ) analog-to-digital converter (ADC). The proposed SO design allows circuit operation at sub-1 V supply voltage, only needs to work in half of a clock cycle, and thus is suitable for low power applications. In addition, an opamp-sharing technique is applied to save on hardware overheads. Due to the use of a dual cycle shift data weighted averaging (DCS-DWA) technique, mismatch errors caused in the feedback DAC have been eliminated without introducing signal-dependent tones. The proposed ADC has been implemented in a standard 0.18 μm process and measured to have a 92.2 dB peak SNDR and 94.1 dB dynamic range with 25 kHz signal bandwidth. The power consumption is 58 μW for the modulator at 0.9 V supply voltage and 96 μW for the decimation filter, which translate to the figure-of-merit (FOM) of 35.4 fJ/step for the solo modulator, and 94 fJ/step for the whole system.

  1. A 10-bit 200-kS/s SAR ADC IP core for a touch screen SoC

    International Nuclear Information System (INIS)

    Tong Xingyuan; Yang Yintang; Zhu Zhangming; Sheng Wenfang

    2010-01-01

    Based on a 5 MSBs (most-significant-bits)-plus-5 LSBs (least-significant-bits) C-R hybrid D/A conversion and low-offset pseudo-differential comparison approach, with capacitor array axially symmetric layout topology and resistor string low gradient mismatch placement method, an 8-channel 10-bit 200-kS/s SAR ADC (successive-approximation-register analog-to-digital converter) IP core for a touch screen SoC (system-on-chip) is implemented in a 0.18 μm 1P5M CMOS logic process. Design considerations for the touch screen SAR ADC are included. With a 1.8 V power supply, the DNL (differential non-linearity) and INL (integral non-linearity) of this converter are measured to be about 0.32 LSB and 0.81 LSB respectively. With an input frequency of 91 kHz at 200-kS/s sampling rate, the spurious-free dynamic range and effective-number-of-bits are measured to be 63.2 dB and 9.15 bits respectively, and the power is about 136 μW. This converter occupies an area of about 0.08 mm 2 . The design results show that it is very suitable for touch screen SoC applications. (semiconductor integrated circuits)

  2. Timing and control requirements for a 32-channel AMU-ADC ASIC for the PHENIX detector

    Energy Technology Data Exchange (ETDEWEB)

    Emery, M.S.; Ericson, M.N.; Britton, C.L. Jr. [and others

    1998-02-01

    A custom CMOS Application Specific Integrated Circuit (ASIC) has been developed consisting of an analog memory unit (AMU) has been developed consisting of an analog memory unit (AMU) and analog to digital converter (ADC), both of which have been designed for applications in the PHENIX experiment. This IC consists of 32 pipes of analog memory with 64 cells per pipe. Each pipe also has its own ADC channel. Timing and control signal requirements for optimum performance are discussed in this paper.

  3. A continuous-time/discrete-time mixed audio-band sigma delta ADC

    Science.gov (United States)

    Yan, Liu; Siliang, Hua; Donghui, Wang; Chaohuan, Hou

    2011-01-01

    This paper introduces a mixed continuous-time/discrete-time, single-loop, fourth-order, 4-bit audio-band sigma delta ADC that combines the benefits of continuous-time and discrete-time circuits, while mitigating the challenges associated with continuous-time design. Measurement results show that the peak SNR of this ADC reaches 100 dB and the total power consumption is less than 30 mW.

  4. The Role of ADC-Based Thermometry in Measuring Brain Intraventricular Temperature in Children.

    Science.gov (United States)

    Wagner, Matthias W; Stern, Steven E; Oshmyansky, Alexander; Huisman, Thierry A G M; Poretti, Andrea

    2016-05-01

    To determine the feasibility of apparent diffusion coefficient (ADC)-based thermometry to assess intraventricular temperature in children. ADC maps were generated from diffusion tensor imaging data, which were acquired with diffusion gradients along 20 noncollinear directions using a b-value of 1000 s/mm(2) . The intraventricular temperature was calculated based on intraventricular ADC values and the mode method as previously reported. The calculated intraventricular temperature was validated with an estimated brain temperature based on temporal artery temperature measurements. We included 120 children in this study (49 females, 71 males, mean age 6.63 years), 15 consecutive children for each of the following age groups: 0-1, 1-2, 2-4, 4-6, 6-8, 8-10, 10-14, and 14-18 years. Forty-three children had a normal brain MRI and 77 children had an abnormal brain scan. Polynomial fitting to the temperature distribution and subsequent calculation of mode values was performed. A correlation coefficient and a coefficient of determination were calculated between ADC calculated temperatures and estimated brain temperatures. Linear regression analysis was performed to investigate the two temperature measures. ADC-based intraventricular temperatures ranged between 31.5 and 39.6 °C, although estimated brain temperatures ranged between 36.3 and 38.1 °C. The difference between the temperatures is larger for children with more than 8,000 voxels within the lateral ventricles compared to children with less than 8,000 voxels. The correlation coefficient between ADC-based temperatures and the estimated brain temperatures is .1, the respective R(2) is .01 indicating that 1% of the changes in estimated brain temperatures are attributable to corresponding changes in ADC-based temperature measurements (P = .275). ADC-based thermometry has limited application in the pediatric population mainly due to a small ventricular size. Copyright © 2015 by the American Society of Neuroimaging.

  5. A FASTBUS flash ADC system for the Mark II vertex chamber

    International Nuclear Information System (INIS)

    Barker, L.

    1988-10-01

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs

  6. A continuous-time/discrete-time mixed audio-band sigma delta ADC

    International Nuclear Information System (INIS)

    Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2011-01-01

    This paper introduces a mixed continuous-time/discrete-time, single-loop, fourth-order, 4-bit audio-band sigma delta ADC that combines the benefits of continuous-time and discrete-time circuits, while mitigating the challenges associated with continuous-time design. Measurement results show that the peak SNR of this ADC reaches 100 dB and the total power consumption is less than 30 mW. (semiconductor integrated circuits)

  7. Timing and control requirements for a 32-channel AMU-ADC ASIC for the PHENIX detector

    International Nuclear Information System (INIS)

    Emery, M.S.; Ericson, M.N.; Britton, C.L. Jr.

    1998-01-01

    A custom CMOS Application Specific Integrated Circuit (ASIC) has been developed consisting of an analog memory unit (AMU) has been developed consisting of an analog memory unit (AMU) and analog to digital converter (ADC), both of which have been designed for applications in the PHENIX experiment. This IC consists of 32 pipes of analog memory with 64 cells per pipe. Each pipe also has its own ADC channel. Timing and control signal requirements for optimum performance are discussed in this paper

  8. Integrating a sampling oscilloscope card and spectroscopy ADCs in a data acquisition system

    CERN Document Server

    Maartensson, L

    2001-01-01

    A high-rate sampling oscilloscope card has been integrated into an existing data acquisition system for spectroscopy ADCs. Experiments where pulse-shape analyses are important have then been made possible. Good performance characteristics of the integrated system have been achieved. Spectroscopy ADC data together with pulse-shape data sampled 512 times at 100 MHz are saved to hard disk at event rates up to about 1 kHz with low dead time losses.

  9. A FASTBUS flash ADC system for the Mark II vertex chamber

    Energy Technology Data Exchange (ETDEWEB)

    Barker, L.

    1988-10-01

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs.

  10. A novel low-voltage operational amplifier for low-power pipelined ADCs

    International Nuclear Information System (INIS)

    Fan Mingjun; Ren Junyan; Guo Yao; Li Ning; Ye Fan; Li Lian

    2009-01-01

    A novel low-voltage two-stage operational amplifier employing class-AB architecture is presented. The structure utilizes level-shifters and current mirrors to create the class-AB behavior in the first and second stages. With this structure, the transconductances of the two stages are double compared with the normal configuration without class-AB behaviors with the same current consumption. Thus power can be saved and the operation frequency can be increased. The nested cascode miller compensation and symmetric common-mode feedback circuits are used for large unit-gain bandwidth, good phase margin and stability. Simulation results show that the sample-and-hold of the 12-bit 40-Ms/s pipelined ADC using the proposed amplifier consumes only 5.8 mW from 1.2 V power supply with signal-to-noise-and-distortion ratio 89.5 dB, spurious-free dynamic range 95.7 dB and total harmonic distortion -94.3 dB with Nyquist input signal frequency.

  11. Improving single slope ADC and an example implemented in FPGA with 16.7 GHz equivalent counter clook frequency

    International Nuclear Information System (INIS)

    Wu, Jinyuan; Odeghe, John; Stackley, Scott; Zha, Charles

    2011-01-01

    Single slope ADC is a common building block in many ASCI or FPGA based front-end systems due to its simplicity, small silicon footprint, low noise interference and low power consumption. In single slope ADC, using a Gray code counter is a popular scheme for time digitization, in which the comparator output drives the clock (CK) port of a register to latch the bits from the Gray code counter. Unfortunately, feeding the comparator output into the CK-port causes unnecessary complexities and artificial challenges. In this case, the propagation delays of all bits from the counter to the register inputs must be matched and the counter must be a Gray code one. A simple improvement on the circuit topology, i.e., feeding the comparator output into the D-port of a register, will avoid these unnecessary challenges, eliminating the requirement of the propagation delay match of the counter bits and allowing the use of regular binary counters. This scheme not only simplifies current designs for low speeds and resolutions, but also opens possibilities for applications requiring higher speeds and resolutions. A multi-channel single slope ADC based on a low-cost FPGA device has been implemented and tested. The timing measurement bin width in this work is 60 ps, which would need a 16.7 GHz counter clock had it implemented with the conventional Gray code counter scheme. A 12-bit performance is achieved using a fully differential circuit making comparison between the input and the ramping reference, both in differential format.

  12. Improved Switching Energy Reduction Approach in Low-Power SAR ADC for Bioelectronics

    Directory of Open Access Journals (Sweden)

    Xingyuan Tong

    2016-01-01

    Full Text Available Low-power analog-to-digital converter (ADC is a crucial part of wearable or implantable bioelectronics. In order to reduce the power of successive-approximation-register (SAR ADC, an improved energy-efficient capacitor switching scheme of SAR ADC is proposed for implantable bioelectronic applications. With sequence initialization, novel logic control, and capacitive subconversion, 97.6% switching energy is reduced compared to the traditional structure. Moreover, thanks to the top-plate sampling and capacitive subconversion, 87% input-capacitance reduction can be achieved over the conventional structure. A 10-bit SAR ADC with this proposed switching scheme is realized in 65 nm CMOS. With 1.514 KHz differential sinusoidal input signals sampled at 50 KS/s, the ADC achieves an SNDR of 61.4 dB and only consumes power of 450 nW. The area of this SAR ADC IP core is only 136 μm × 176 μm, making it also area-efficient and very suitable for biomedical electronics application.

  13. Effect of testing position on dynamic visual acuity.

    Science.gov (United States)

    Danenbaum, Elizabeth; Chilingaryan, Gevorg; Fung, Joyce

    2008-12-01

    To investigate the effect of altering testing position on dynamic visual acuity (DVA) in vestibulopathic adults. Quasiexperimental research. Outpatient vestibular program. Twelve vestibulopathic adults with impaired DVA in the sitting position. DVA scores were collected during (1) sitting, (2) standing comfortably, and (3) semitandem standing as subjects viewed a vision (E) chart 3.48 m in front of them. DVA was obtained as the head was passively moved by the evaluator at a frequency of 1.5 Hz in both horizontal and vertical directions. A further subgroup of subjects (n=5) was retested after performing the "viewing x1" gaze stability home exercise four times daily (1 minute duration in the horizontal direction while sitting) for 2 months. Noncomputerized DVA score. The DVA score remained constant independent of testing position as the Friedman test did not reveal any significant differences in the DVA scores in the horizontal or vertical direction. Subjects who improved after performing the viewing x1 exercise in the horizontal direction in the sitting position tended to have the same improvement in DVA in all three positions. The results of this study show that DVA score is independent of testing position. This is clinically important since it shows that the results of DVA testing in one position are valid for other positions and that subjects can be trained to improve their DVA in a sitting posture while having carry-over effects to other, more challenging postures.

  14. Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.

    Science.gov (United States)

    Kim, Jong Hoon; Lee, Jyung Hyun; Cho, Jin-Ho

    2017-07-20

    The hearing impaired population has been increasing; many people suffer from hearing problems. To deal with this difficulty, various types of hearing aids are being rapidly developed. In particular, fully implantable hearing aids are being actively studied to improve the performance of existing hearing aids and to reduce the stigma of hearing loss patients. It has to be of small size and low-power consumption for easy implantation and long-term use. The objective of the study was to implement a small size and low-power consumption successive approximation register analog-to-digital converter (SAR ADC) for fully implantable hearing aids. The ADC was selected as the SAR ADC because its analog circuit components are less required by the feedback circuit of the SAR ADC than the sigma-delta ADC which is conventionally used in hearing aids, and it has advantages in the area and power consumption. So, the circuit of SAR ADC is designed considering the speech region of humans because the objective is to deliver the speech signals of humans to hearing loss patients. If the switch of sample and hold works in the on/off positions, the charge injection and clock feedthrough are produced by a parasitic capacitor. These problems affect the linearity of the hold voltage, and as a result, an error of the bit conversion is generated. In order to solve the problem, a CMOS switch that consists of NMOS and PMOS was used, and it reduces the charge injection because the charge carriers in the NMOS and PMOS have inversed polarity. So, 16 bit conversion is performed before the occurrence of the Least Significant Bit (LSB) error. In order to minimize the offset voltage and power consumption of the designed comparator, we designed a preamplifier with current mirror. Therefore, the power consumption was reduced by the power control switch used in the comparator. The layout of the designed SAR ADC was performed by Virtuoso Layout Editor (Cadence, USA). In the layout result, the size of the

  15. Dynamic testing of nuclear power plant structures: an evaluation

    International Nuclear Information System (INIS)

    Weaver, H.J.

    1980-02-01

    Lawrence Livermore Laboratory (LLL) evaluated the applications of system identification techniques to the dynamic testing of nuclear power plant structures and subsystems. These experimental techniques involve exciting a structure and measuring, digitizing, and processing the time-history motions that result. The data can be compared to parameters calculated using finite element or other models of the test systems to validate the model and to verify the seismic analysis. This report summarizes work in three main areas: (1) analytical qualification of a set of computer programs developed at LLL to extract model parameters from the time histories; (2) examination of the feasibility of safely exciting nuclear power plant structures and accurately recording the resulting time-history motions; (3) study of how the model parameters that are extracted from the data be used best to evaluate structural integrity and analyze nuclear power plants

  16. Testing the Lag Structure of Assets’ Realized Volatility Dynamics

    Directory of Open Access Journals (Sweden)

    Francesco Audrino

    2017-12-01

    Full Text Available A (conservative test is applied to investigate the optimal lag structure for modelingrealized volatility dynamics. The testing procedure relies on the recent theoretical results that showthe ability of the adaptive least absolute shrinkage and selection operator (adaptive lasso to combinee cient parameter estimation, variable selection, and valid inference for time series processes. In anapplication to several constituents of the S&P 500 index it is shown that (i the optimal significantlag structure is time-varying and subject to drastic regime shifts that seem to happen across assetssimultaneously; (ii in many cases the relevant information for prediction is included in the first 22lags, corroborating previous results concerning the accuracy and the diffculty of outperforming outof-sample the heterogeneous autoregressive (HAR model; and (iii some common features of theoptimal lag structure can be identified across assets belonging to the same market segment or showinga similar beta with respect to the market index.

  17. Comparison of ADC values in different malignancies of the skeletal musculature: a multicentric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey [Martin-Luther-University Halle-Wittenberg, Department of Radiology, Halle (Germany); University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Nagata, Shuji [Kurume University School of Medicine, Department of Radiology, Kurume (Japan); Razek, Ahmed A. Abd [Mansoura Faculty of Medicine, Department of Diagnostic Radiology, Mansoura (Egypt); Tirumani, Sree Harsha [Harvard Medical School, Department of Imaging, Dana-Farber Cancer Institute and Department of Radiology, Brigham and Women' s Hospital, Boston, MA (United States); Wienke, Andreas [Martin-Luther-University Halle-Wittenberg, Institute of Medical Epidemiology, Biometry, and Statistics, Halle (Germany); Kahn, Thomas [University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany)

    2015-04-28

    Diffusion-weighted imaging (DWI) provides essential information regarding tumor composition, such as cellularity and/or perfusion. DWI is helpful in distinguishing between malignant and benign lesions. Malignant intramuscular/soft tissue lesions consist of a wide spectrum of tumors that have different cell counts and matrix. It is presumed that these different tumors have different DWI findings and have different apparent diffusion coefficient (ADC) values. The aim of this study was to analyze DWI findings of different intramuscular malignancies in a multicentric study by using a standardized DWI protocol, and to compare the ADC values acquired. The data banks of four radiology departments were screened retrospectively for malignant intramuscular tumors. Only lesions that were investigated by MRI (with a 1.5-T scanner) using DWI (multishot EPI sequence with b values of 0 and 1,000 s/mm{sup 2}) were included in the study. Overall, 51 patients (28 women, 23 men; mean age 58.8 ± 16.1 years) with 57 different malignant intramuscular lesions were collected. In every case apparent diffusion constant (ADC) maps were calculated. In 14 patients muscle lymphoma, 11 patients intramuscular metastases from different primary tumors, and in 26 cases several muscle sarcomas were identified. The mean ADC value of the estimated lesions was 1.24 ± 0.53 x 10{sup -3} mm{sup 2}s{sup -1}, median value, 1.11 x 10{sup -3} mm{sup 2}s{sup -1}, range, 0.54-2.9 x 10{sup -3} mm{sup 2}s{sup -1}. The mean ADC value in muscle metastases was 1.28 ± 0.24 x 10{sup -3} mm{sup 2}s{sup -1}, in muscle lymphoma 0.76 ± 0.14 x 10{sup -3} mm{sup 2}s{sup -1}, and in muscle sarcomas 1.82 ± 0.63 x 10{sup -3} mm{sup 2}s{sup -1}. Muscle lymphoma showed statistically significant lower ADC values in comparison to muscle metastases (p = 0.01) and muscle sarcoma (p = 0.001). There was no significant differences between ADC values in muscle metastases and sarcomas (p = 0.48). ADC values in muscle lymphoma were

  18. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    International Nuclear Information System (INIS)

    Giannotti, E.; Waugh, S.; Priba, L.; Davis, Z.; Crowe, E.; Vinnicombe, S.

    2015-01-01

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC S ) and the ADC value of a small region of interest (ROI) on the same slice (ADC min ). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10 −3 mm 2 /s; mean ADC = 1.089 × 10 −3 mm 2 /s). The measured scan-scan CoR in the volunteers was 0.122 × 10 −3 mm 2 /s, contributing an error of 8% to the mean measured values (ADC scan1 = 1.529 × 10 −3 mm 2 /s; ADC scan

  19. Discrimination between intact and decayed pulp regions in carious teeth by ADC mapping.

    Science.gov (United States)

    Cankar, Ksenija; Nemeth, Lidija; Bajd, Franci; Vidmar, Jernej; Serša, Igor

    2014-01-01

    The aim of this study was to evaluate an advanced magnetic resonance imaging (MRI) method, apparent diffusion coefficient (ADC) mapping, in the functional assessment of carious teeth. 38 extracted human teeth with scores of 0, 3 and 6 according to International Caries Detection and Assessment System (ICDAS) criteria were screened and subsequently analyzed by MRI at 2.35 T. Histology sectioning of teeth was used for the gold standard by analyzing two extreme cases (intact and severely decayed). ADC maps of the same teeth were calculated from corresponding diffusion-weighted images and used to obtain ADC distributions along dental pulp as functions of the relative pulp length measured from the occlusal pulp side. The measured distributions were analyzed for the best fit by a four-parameter three-segment linear regression model for ADC distribution along the pulp. MRI results were in good agreement with findings in histological sections of identical teeth. The best fit model parameters, relative decayed region depth, relative transition region width and ADC values of intact and decayed pulp tissue, showed statistically significant differences between the ADC values of intact and decayed pulp tissue (1.0 × 10(-9) m(2)/s vs. 0.74-0.89 × 10(-9) m(2)/s) and the relative decayed region depth progressing with ICDAS score (3 vs. 46% with ICDAS 3 vs. ICDAS 6). The results of this feasibility study confirmed relevance of ADC mapping for the discrimination and localization of intact and decayed regions in dental pulps of carious teeth. © 2014 S. Karger AG, Basel.

  20. Induction Heating on Dynamic Tensile Tests in CEA Saclay

    International Nuclear Information System (INIS)

    Averty, X.; Yvon, P.; Duguay, C.; Pizzanelli, J. P.; Basini, V.

    2001-01-01

    The LCMI (Laboratory for characterization of irradiated materials), located in CEA from Saclay, is in charge of the mechanical tests on irradiated materials. The dynamic tensile testing machine, in a hot cell equipped with two remote handling, has been first improved in 1995, to fulfill the French safety programs on Reactivity Initiated Accident (RIA). One objective of this machine is to obtain mechanical property data on current Zircaloy cladding types needed to quality the cladding's response under RIA or LOCA transient loading and thermal conditions. For the RIA, this means testing at strain rates up to 5 s' and heating rates up to 200 degree centigree-s''-1, while for Loss of Coolant Accidents (LOCA) testing at strain rates of 10''-3 s''-1 and heating rates of 20 degree centigree s''-1 would be appropriate. The tensile samples are machined with a spark erosion machine, directly from pieces of cladding previously de fueled. Two kinds of samples can be machined in the cladding. Axial samples in order to test axial mechanical characteristics Ring samples in order to test transverse mechanical characteristics, more representative of RIA conditions. On one hand, the axial tensile tests were performed using the Joule effect, and heating rates up to about 500 degree centigree .s''-1 were obtained. This enabled us to perform the axial tests in a satisfactory manner. On the other hand, the tensile ring were first performed in a vertical furnace with a heating rate about 0.2 degree centigree.s''-1 and a thermal stability about 1 degree centigree. For temperatures above 480 degree centigree, the mechanical characteristics showed a sharp drop which could be attributed to irradiation defect annealing. Therefore we have recently developed an induction heating system to reach heating rates high enough (200 degree centigree.s''-1) to prevent any significant annealing before performing the ring tensile tests. To apply a uniaxial tangential tension, two matching half

  1. Scoping Future Policy Dynamics in Raw Materials Through Scenarios Testing

    Science.gov (United States)

    Correia, Vitor; Keane, Christopher; Sturm, Flavius; Schimpf, Sven; Bodo, Balazs

    2017-04-01

    The International Raw Materials Observatory (INTRAW) project is working towards a sustainable future for the European Union in access to raw materials, from an availability, economical, and environmental framework. One of the major exercises for the INTRAW project is the evaluation of potential future scenarios for 2050 to frame economic, research, and environmental policy towards a sustainable raw materials supply. The INTRAW consortium developed three possible future scenarios that encompass defined regimes of political, economic, and technological norms. The first scenario, "Unlimited Trade," reflects a world in which free trade continues to dominate the global political and economic environment, with expectations of a growing demand for raw materials from widely distributed global growth. The "National Walls" scenario reflects a world where nationalism and economic protectionism begins to dominate, leading to stagnating economic growth and uneven dynamics in raw materials supply and demand. The final scenario, "Sustainability Alliance," examines the dynamics of a global political and economic climate that is focused on environmental and economic sustainability, leading towards increasingly towards a circular raw materials economy. These scenarios were reviewed, tested, and provided simulations of impacts with members of the Consortium and a panel of global experts on international raw materials issues which led to expected end conditions for 2050. Given the current uncertainty in global politics, these scenarios are informative to identifying likely opportunities and crises. The details of these simulations and expected responses to the research demand, technology investments, and economic components of raw materials system will be discussed.

  2. Testing the local spacetime dynamics by heliospheric radiocommunication methods

    Directory of Open Access Journals (Sweden)

    H.-J. Fahr

    2008-05-01

    Full Text Available According to general relativistic theories, cosmological spacetime is dynamic. This prediction is in excellent agreement with the huge majority of astronomical observations on large cosmic scales, especially the observations of cosmological redshifts of distant galaxies. However, on scales of heliospheric distances, verifications of general relativistic effects are based on Schwarzschild metric tests or kinetical corrections, such as the perihelion motion of Mercury, photon deflection at the Sun and gravitational photon redshifts in central gravity fields. As we will show in this paper, there is, however, a chance to detect new cosmologically relevant features on heliospheric scales by careful study of photon propagations in the local spacetime metrics, based on red- or blueshifts as a clear, but up to now overlooked, signature of the local spacetime dynamics. Thus, we propose the challenging possibility of carrying out experiments of cosmological relevance by simply using high-precision radio tracking of heliospheric spaceprobes, as already practised in cases like Pioneer-10/11, Galileo and Ulysses.

  3. Dynamic tensile test of single PET textile cables

    Directory of Open Access Journals (Sweden)

    Pasco F.

    2012-08-01

    Full Text Available The tyres conception involves for certain applications, the use of textile cables as reinforcement. During its use, the tyre undergoes temperatures variations and dynamic loading rates. The consideration of these conditions during the numeric simulations requires the knowledge of the sensitivity of the mechanical behaviour to loading rate and temperature. In this paper, we developed an experimental methodology for testing textile cable up to high strain rate. The main difficulty of testing cables is the optimization of cable fixing on the machine. For that purpose, we adapted the solution of fixing by progressive binding already used in quasi-static, while taking into account constraints inherent to high strain tests. Firstly, the mass of grips was decreased in order to get force signal less sensitive to grips inertia. The method was developed on a high speed hydraulic machine equipped with a thermal enclosure. The investigated temperatures and strain rates range from room temperature to 373 ∘K (100 ∘C and from 0,01 to 100/s, respectively. In addition, the hydraulic machine was equipped with a high speed video camera. The obtained images were analysed by a tracking technique to measure the average strain in the cable (from 50 to 20000 f/s.

  4. Development of test methodology for dynamic mechanical analysis instrumentation

    Science.gov (United States)

    Allen, V. R.

    1982-01-01

    Dynamic mechanical analysis instrumentation was used for the development of specific test methodology in the determination of engineering parameters of selected materials, esp. plastics and elastomers, over a broad range of temperature with selected environment. The methodology for routine procedures was established with specific attention given to sample geometry, sample size, and mounting techniques. The basic software of the duPont 1090 thermal analyzer was used for data reduction which simplify the theoretical interpretation. Clamps were developed which allowed 'relative' damping during the cure cycle to be measured for the fiber-glass supported resin. The correlation of fracture energy 'toughness' (or impact strength) with the low temperature (glassy) relaxation responses for a 'rubber-modified' epoxy system was negative in result because the low-temperature dispersion mode (-80 C) of the modifier coincided with that of the epoxy matrix, making quantitative comparison unrealistic.

  5. The application of MR DWI sequences and apparent diffusion coefficient values in dynamic evaluation of the efficacy of transcatheter arterial chemoembolization for primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Luo Min; Gao Yuantong; Peng Wenxian; Feng Xiaofeng; Li Yongchou

    2010-01-01

    Objective: To discuss the value of MR diffusion-weighted imaging (DWI) sequences and apparent diffusion coefficient (ADC) values in dynamically assessing the therapeutic efficacy of transcatheter arterial chemoembolization for primary hepatocellular carcinoma. Methods: Routine MRI,dynamic contrast enhanced and DWI (b = 0, 200, 500 and 800 s/mm 2 ) were performed in patients with primary hepatocellular carcinoma both before and after they received transcatheter arterial chemoembolization treatment. The ADC values of 0 -500 were measured, and the results were compared with the angiographic and biochemical findings. Results: After the interventional treatment the ADC value was increased. The postoperative ADC value in patients with better results was higher than that in patients with moderate effectiveness. In the above patients the difference between preoperative ADC value and postoperative ADC value was statistically significant (P < 0.05). While in patients presenting poor effectiveness the postoperative ADC value was not significantly different from preoperative ADC value. During the follow-up period ADC value showed no marked reduction in patients with good therapeutic efficacy, while an obvious decrease in ADC value was observed in patients with moderate or poor efficacy. Enhanced MRI, DWI sequences and angiography clearly demonstrated the survival sites and relapse of the tumor cells. Conclusion: DWI and ADC value can dynamically reflect the necrosis, survival and recurrence of the primary hepatocellular carcinoma after interventional therapy, which is very useful for promptly and effectively evaluating the therapeutic efficacy. (authors)

  6. Reversal of apparent diffusion coefficient (ADC) following transient focal cerebral ischemia in cats

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Yoon, Yong Kyu; Kim, Dong Ik; Lee, Seung Koo

    2002-01-01

    To determine the minimal threshold ADC ratio suggesting reversible ischemia in a temporary model of MCAO. Seven Korean cats weighing 3-3.5 kg were used as a temporary model of MCAO. The MCA was occluded for 1 hour, and diffusion-weighted images (DWI), and ADC and regional cerebral blood volume (rCBV) maps, were obtained at 1, 3, 6 and 24 hours after reperfusion using a 1.5T MR unit. The Cats were sacrificed 24 hours after imaging. Triphenyl tetrazolium chloride (TTC) staining of brain slices was performed, and DWI images and TTC-stained brain slices were compared with the naked eye. Reversible ischemia was defined as the area of high signal intensity at 1-hour DWI that normalized at follow-up DWI and in which TTC staining was normal. Using the ADC image obtained at 1 hour after reperfusion, 60 ADC ratios were obtained in the periphery of the infarct and reversible ischemia. Tissue survival showing normal TTC staining was used for final determination. The sensitivity and specificity of each ADC ratio was obtained and an ROC curve was plotted. Five of seven cats showed the reversible ischemia. An area of high signal intensity was seen on DWI images obtained 1 hours after reperfusion, and this improved at follow-up imaging. The distribution of the ADC ratio in the periphery of the infarct core was 0.71-0.81, and in the periphery of reversible ischemia it was 0.79-0.93. The ADC ratio of 0.80 obtained 1 hr after reperfusion predicted the survival of the ischemic tissure with 93% sensitivity and 90% specificity. The ADC ratio of the reversible ischemia was 0.82 ±0.03 at 1 hour after reperfusion, and this was higher than that of the infarct, which was 0.74±0.03. The minimal threshold ADC ratio suggesting reversible ischemia in this temporary model of MCAO was 0.80

  7. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Steven Shinn-Forng [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); Jeng, Yung-Ming [National Taiwan University, Department of Pathology, Medical College and Hospital, Taipei (China); Hsu, Wen-Ming; Ho, Ming-Chih [National Taiwan University, Department of Surgery, Medical College and Hospital, Taipei, Taiwan (China); Yang, Justin Cheng-Ta [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); National Taiwan University, Institute of Biomedical Engineering, College of Engineering and College of Medicine, Taipei (China)

    2015-10-15

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm{sup 2} in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R{sup 2} = 0.398, p = 0.024 and R{sup 2} = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  8. The appearance of ADCs in the non-affected areas of the patients with MELAS

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhenghua; Liu, Xiwei; Hui, Lihong; Xie, Sheng; Xiao, Jiangxi; Jiang, Xuexiang [Peking University First Hospital, Center for Functional Imaging, Peking University, The Department of Radiology, Beijing (China); Zhao, Danhua [Peking University First Hospital, The Department of Neurology, Beijing (China); Wang, Xiaoying [Peking University First Hospital, Center for Functional Imaging, Peking University, The Department of Radiology, Beijing (China); Peking University First Hospital, The Department of Radiology, 8, Xishiku Street, Xicheng District, Beijing (China)

    2011-04-15

    The exact mechanism of the mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) remain unclear. Diffusion-weighted imaging (DWI) is a magnetic resonance (MR) imaging technique for studying the pathophysiologic change of the MELAS. The purpose of the study is to see whether the apparent diffusion coefficient (ADC) of MELAS in the non-affected areas is different from the ADC of the normal subjects and to speculate the pathophysiological mechanisms of the MELAS. Sixteen cases of MELAS were retrospectively analyzed. Thirty healthy subjects were chosen to constitute the control group. All of them were performed on the 3.0T whole-body MR scanner with axial view T2 fluid attenuated inversion recovery (flair), T2-weighted imaging, T1flair, and DWI. An ADC map was reconstructed in the workstation. Two to five regions of interest were put in the non-affected frontal lobe and basal ganglia. All data took statistical analysis. There were significant differences between the ADC of the patients with MELAS and the controls in the non-affected areas, including the superior frontal gyrus, precentral gyrus, corpus striatum, thalamus, and white matter of the semi-oval centrum. ADCs in the non-affected areas of the patients with MELAS are higher than those of the normal subjects. Pathological changes take place in the non-affected areas of the patients with MELAS. (orig.)

  9. Photoluminescence detection of alpha particle using DAM-ADC nuclear detector

    International Nuclear Information System (INIS)

    Abdalla, Ayman M.; Harraz, Farid A.; Ali, Atif M.; Al-Sayari, S.A.; Al-Hajry, A.

    2016-01-01

    The photoluminescence (PL) and UV–vis spectral analysis of DAM-ADC (diallyl maleate: DAM, polyallyl diglycol carbonate: ADC) nuclear detector are demonstrated for the first time. The DAM-ADC surfaces were exposed to thin 241 Am disk source that emits alpha particles with activity 333 kBq. It is found that the track density of the irradiated samples remarkably influences the PL characteristics of the DAM-ADC detector. The spectral peak heights and the integrated intensities under the peaks exhibit linear correlations with correlation coefficient R 2 =0.9636 and 0.9806, respectively for different alpha particle fluences ranging from 8.16–40.82×10 7 particles/cm 2 . Additionally, a correlation coefficient R 2 =0.9734 was achieved for the UV–vis spectral analysis. The linear fitting functions, along with the corresponding fitting parameters were evaluated in each case. Both the PL and the UV–vis data of the irradiated DAM-ADC samples showed considerable spectral differences, and hence they would be used to offer sensitive approaches for alpha particle detection.

  10. Dynamic testing of cognitive abilities of children and adolescents

    OpenAIRE

    Rybářová, Karolína

    2014-01-01

    The thesis presents a dynamic approach to the assessment in school psychology and the current practice of its application with an emphasis on the context of the Czech environment. Characteristics of dynamic assessment, theoretical background and a comparison with traditional assessment are defined. The largest part is devoted to the use of dynamic assessment in practice. Various methods of dynamic assessment and their possible uses and applications are described. The text also discusses the r...

  11. Dynamic radioisotopic study of the salivary glands. Quantification test

    International Nuclear Information System (INIS)

    Estour, A.-B.

    1976-01-01

    Quantified dynamic radioisotopic exploration, a new and rational examination, should find its place in a thorough check-up of the salivary glands together with clinical, immunological, anatomopathological and sialographic investigations. The object of this work was to standardise the test procedure with a view to routine use on patients and to define certain quantified parameters representing objectively the different aspects of the salivary functions. Our procedure through reeding sophisticated equipment, is simple to perform and relies on use of: radiotechnetium employed at activities which allow repetitive exlorations whereby pathological changes may be followed; the gamma camera and its data processing system which records all radioactive information obtained on the patient's head. These results will supply the data needed to judge the salivary functions as a whole. The apparatus used provides a remarkable pictorial record made up not only of morphological and functional images at each stage of the examination but also of ciphered radioactivity versus time curves for each of the main salivary glands and for any other zone of interest. From these curves it is then possible to define quantified parameters, reproducible and expressing functional activity. This procedure, safe and painless, seems to suit the patients who lie still without complaint for 60 minutes, 45 minutes for the concentration study and 15 minutes for the post-stimulus excretion study. The dynamic radioisotopic examination of the salivary glands, by the comparison of concentration and excretion images and by the study of parameters, separately and as a whole, is thus a useful complement to other paraclinical examinations and contributes essential information in most salivary diseases [fr

  12. 16 CFR 1203.16 - Dynamic strength of retention system test.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Dynamic strength of retention system test.... (2) The retention system strength test equipment shall consist of a dynamic impact apparatus that... ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.16 Dynamic strength of...

  13. Power-efficient high-speed parallel-sampling adcs for broadband multi-carrier systems

    CERN Document Server

    Lin, Yu; Doris, Kostas; van Roermund, Arthur H M

    2015-01-01

    This book addresses the challenges of designing high performance analog-to-digital converters (ADCs) based on the “smart data converters” concept, which implies context awareness, on-chip intelligence and adaptation. Readers will learn to exploit various information either a-priori or a-posteriori (obtained from devices, signals, applications or the ambient situations, etc.) for circuit and architecture optimization during the design phase or adaptation during operation, to enhance data converters performance, flexibility, robustness and power-efficiency. The authors focus on exploiting the a-priori knowledge of the system/application to develop enhancement techniques for ADCs, with particular emphasis on improving the power efficiency of high-speed and high-resolution ADCs for broadband multi-carrier systems.

  14. XML at the ADC: Steps to a Next Generation Data Repository

    Science.gov (United States)

    Shaya, E.; Gass, J.; Blackwell, J.; Thomas, B.; Holmes, B.; Cheung, C. Y.

    The staff of the Astronomical Data Center at GSFC (ADC, http://adc.gsfc.nasa.gov) is involved in a research project to define the XML format for the metadata of an astronomical repository and for large data tables. In the process, an XML tool box is being developed for importation, enhancement, and distribution of published data and their metadata documents. There is now a working draft Document Type Definition (DTD, http://messier.gsfc.nasa.gov/xml/dataset.dtd) which specifies the required elements of content and their attributes. The documentation for each data set will be viewable in several different styles via eXtensible Stylesheet Language Transformations (XSLT, (http://www.w3.org/TR/xslt) scripts. The ADC is actively creating designs for the flow of data through automated pipelines from authors and journal presses into an XML archive, as well as data retrieval through the web via the XML Query Language.

  15. Diffusion weighted imaging of liver lesions suspect for metastases: Apparent diffusion coefficient (ADC) values and lesion contrast are independent from Gd-EOB-DTPA administration

    Energy Technology Data Exchange (ETDEWEB)

    Benndorf, Matthias, E-mail: matthias.benndorf@uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany); Schelhorn, Juliane, E-mail: j.schelhorn@klinikum-weimar.de [Department of Radiology and Nuclear Medicine, Sophien- und Hufeland-Klinikum Weimar, Henry-van-de-Velde-Strasse 2, 99425 Weimar (Germany); Dietzel, Matthias, E-mail: matthias.dietzel@med.uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany); Kaiser, Werner A., E-mail: werner.kaiser@med.uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany); Baltzer, Pascal A.T., E-mail: pascal.baltzer@med.uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany)

    2012-08-15

    Purpose: Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) enhanced liver MRI is widely used for detection and differentiation of focal liver lesions. Diffusion weighted imaging (DWI) including apparent diffusion coefficient (ADC) measurements is increasingly utilised as a fast and, with limitations, quantitative method for liver lesion detection and characterisation. Herein we investigate whether the administration of Gd-EOB-DTPA affects DWI. Materials and methods: 31 consecutive patients referred to standardised liver MRI (1.5 T, Gd-EOB-DTPA, 0.025 mmol/kg) were retrospectively reviewed. All underwent a breathhold DWI sequence before and after contrast agent administration (EPI-DWI, TR/TE (effective): 2100/62 ms, b-values: 0 and 800 s/mm{sup 2}). Patients with previously treated liver lesions were excluded. Signal intensity of lesion, parenchyma and noise on DWI images as well as the ADC value were measured after identification by two observers in consensus using manually placed regions of interest. The reference standard was imaging follow-up determined separately by two radiologists. Data analysis included signal-to-noise (SNR) ratio and contrast-to-noise ratio (CNR) calculations, comparisons were drawn by employing multiple Bonferroni corrected Wilcoxon signed-rank tests. Results: 50 malignant and 39 benign lesions were identified. Neither SNR, CNR nor ADC values showed significant differences between pre- and postcontrast DWI. Both pre- and postcontrast ADC values differed significantly between benign and malignant lesions (P < 0.001). Conclusion: We did not identify a significant influence of Gd-EOB-DTPA on DWI of liver lesions. This allows for individual tailoring of imaging protocols according to clinical needs.

  16. Site-Dependent Degradation of a Non-Cleavable Auristatin-Based Linker-Payload in Rodent Plasma and Its Effect on ADC Efficacy.

    Directory of Open Access Journals (Sweden)

    Magdalena Dorywalska

    Full Text Available The efficacy of an antibody-drug conjugate (ADC is dependent on the properties of its linker-payload which must remain stable while in systemic circulation but undergo efficient processing upon internalization into target cells. Here, we examine the stability of a non-cleavable Amino-PEG6-based linker bearing the monomethyl auristatin D (MMAD payload site-specifically conjugated at multiple positions on an antibody. Enzymatic conjugation with transglutaminase allows us to create a stable amide linkage that remains intact across all tested conjugation sites on the antibody, and provides us with an opportunity to examine the stability of the auristatin payload itself. We report a position-dependent degradation of the C terminus of MMAD in rodent plasma that has a detrimental effect on its potency. The MMAD cleavage can be eliminated by either modifying the C terminus of the toxin, or by selection of conjugation site. Both approaches result in improved stability and potency in vitro and in vivo. Furthermore, we show that the MMAD metabolism in mouse plasma is likely mediated by a serine-based hydrolase, appears much less pronounced in rat, and was not detected in cynomolgus monkey or human plasma. Clarifying these species differences and controlling toxin degradation to optimize ADC stability in rodents is essential to make the best ADC selection from preclinical models. The data presented here demonstrate that site selection and toxin susceptibility to mouse plasma degradation are important considerations in the design of non-cleavable ADCs, and further highlight the benefits of site-specific conjugation methods.

  17. Perceptions and Attitudes towards Medical Research in the United Arab Emirates: Results from the Abu Dhabi Cohort Study (ADCS) Focus Group Discussions.

    Science.gov (United States)

    El Obaid, Yusra; Al Hamiz, Aisha; Abdulle, Abdishakur; Hayes, Richard B; Sherman, Scott; Ali, Raghib

    2016-01-01

    In developing medical research, particularly in regions where medical research is largely unfamiliar, it is important to understand public perceptions and attitudes towards medical research. In preparation for starting the first cohort study in the United Arab Emirates, the Abu Dhabi Cohort Study (ADCS), we sought to understand how we could improve the quality of the research process for participants and increase public trust and awareness of research. We conducted six focus groups (FG), consisting of Emirati men and women aged above 18 years to resemble the target population for the ADCS. Sampling was purposive and convenient. Data collection was an iterative process until saturation was reached with no new themes identified. Text from each FG was analyzed separately by identifying emerging issues and organizing related concepts into categories or themes. A coding tree was developed, consisting of the main concepts, themes, subthemes and corresponding quotes. Both themes and main ideas were identified using inductive analysis. Forty-two participants enrolled at 3 academic centers (New York University Abu Dhabi, UAE University, Zayed University) and the Abu Dhabi blood bank. Focus group participants described lack of awareness of research as a challenge to participation in clinical research studies. Altruism, personal relevance of the research, and the use of role models were commonly identified motivators. Participants were generally satisfied with the informed consent process for the ADCS, but would be disappointed if not provided test results or study outcomes. Fear of a breach in confidentiality was a frequently expressed concern. Participants join research studies for varied, complex reasons, notably altruism and personal relevance. Based on these insights, we propose specific actions to enhance participant recruitment, retention and satisfaction in the ADCS. We identified opportunities to improve the research experience through improved study materials and

  18. Cochlear function tests in estimation of speech dynamic range.

    Science.gov (United States)

    Han, Jung Ju; Park, So Young; Park, Shi Nae; Na, Mi Sun; Lee, Philip; Han, Jae Sang

    2016-10-01

    The loss of active cochlear mechanics causes elevated thresholds, loudness recruitment, and reduced frequency selectivity. The problems faced by hearing-impaired listeners are largely related with reduced dynamic range (DR). The aim of this study was to determine which index of the cochlear function tests correlates best with the DR to speech stimuli. Audiological data on 516 ears with pure tone average (PTA) of ≤55 dB and word recognition score of ≥70% were analyzed. PTA, speech recognition threshold (SRT), uncomfortable loudness (UCL), and distortion product otoacoustic emission (DPOAE) were explored as the indices of cochlear function. Audiometric configurations were classified. Correlation between each index and the DR was assessed and multiple regression analysis was done. PTA and SRT demonstrated strong negative correlations with the DR (r = -0.788 and -0.860, respectively), while DPOAE sum was moderately correlated (r = 0.587). UCLs remained quite constant for the total range of the DR. The regression equation was Y (DR) = 75.238 - 0.719 × SRT (R(2 )=( )0.721, p equation.

  19. Stress-testing Control Structures for Dynamic Dispatch in Java

    OpenAIRE

    Zendra, Olivier; Driesen, Karel

    2002-01-01

    Dynamic dispatch, or late binding of function calls, is a salient feature of object-oriented programming languages like C++ and Java. It can be costly on deeply pipelined processors, because dynamic calls translate to hard-to-predict indirect branch instructions, which are prone to causing pipeline bubbles. Several alternative implementation techniques have been designed in the past in order to perform dynamic dispatch without relying on these expensive branch instructions. Unfortunately it i...

  20. Experimental investigations on dynamic effects in impact notch bending tests

    International Nuclear Information System (INIS)

    Boehme, W.

    1985-06-01

    The dynamic behaviour of three point bending samples under impact stresses is examined experimentally. Various measuring processes, above all the shadow optics etching process are used. A quasi-static analysis is made by a simple spring/mass model to describe the stress behaviour quantitatively. Based on this, the dynamic effects in model experiments are measured quantitatively with dynamic correction functions and are discussed with reference to the wave processes in the sample. A systematic view of the effect of the many system parameters on the dynamic stress behaviour is obtained. Finally, examples show that the results of this model investigation can be transferred to other experimental conditions. (orig./HP) [de

  1. Aristotle's 'completeness test' as Heuristics for an Account of Dynamicity

    DEFF Research Database (Denmark)

    Seibt, Johanna

    2015-01-01

    If being were ‘dynamic,’ would it be more amenable to a definition? In this paper I present a number of preliminary considerations for an exploration of this question. Working from the methodological stance of analytical ontology, I assume that the first task for an ontology of dynamic being(s) m...

  2. A Cryogenic 1 GSa/s, Soft-Core FPGA ADC for Quantum Computing Applications

    NARCIS (Netherlands)

    Homulle, H.A.R.; Charbon, E.E.E.

    2016-01-01

    We propose an analog-to-digital converter (ADC) architecture, implemented in an FPGA, that is fully reconfigurable and easy to calibrate. This approach allows to alter the design, according to the system requirements, with simple modifications in the firmware. Therefore it can be used in a wide

  3. A low-power time-domain VCO-based ADC in 65 nm CMOS

    Science.gov (United States)

    Chenluan, Wang; Shengxi, Diao; Fujiang, Lin

    2014-10-01

    A low-power, high-FoM (figure of merit), time-domain VCO (voltage controlled oscillator)-based ADC (analog-to-digital converter) in 65 nm CMOS technology is proposed. An asynchronous sigma—delta modulator (ASDM) is used to convert the voltage input signal to a square wave time signal, where the information is contained in its pulse-width. A time-domain quantizer, which uses VCO to convert voltage to frequency, is adopted, while the XOR (exclusive-OR) gate circuits convert the frequency information to digital representatives. The ASDM does not need an external clock, so there is no quantization noise. At the same time, the ASDM applies a harmonic-distortion-cancellation technique to its transconductance stage, which increases the SNDR (signal to noise and distortion ratio) performance of the ASDM. Since the output of the ASDM is a two-level voltage signal, the VCO's V—F (voltage to frequency) conversion curve is always linear. The XOR phase quantizer has an inherent feature of first-order noise-shaping. It puts the ADC's low-frequency output noise to high-frequency which is further filtered out by a low-pass filter. The proposed ADC achieves an SNR/SNDR of 54. dB/54.3 dB in the 8 MHz bandwidth, while consuming 2.8 mW. The FoM of the proposed ADC is a 334 fJ/conv-step.

  4. 0.5 ns resolution, 8-bit time-to-digital converter with flash ADC

    International Nuclear Information System (INIS)

    Sobczynski, C.

    1987-01-01

    A two-channel time-to-digital converter based on an 8-bit flash ADC is presented. The full scale time range of 127.5 ns is digitized to 8 bits providing 500 ps time resolution. The conversion time per channel is less than 800 ns. The design is foreseen to be implemented into Fastbus. (orig.)

  5. Modifications of the optical properties for DAM-ADC nuclear track detector exposed to alpha particles

    Science.gov (United States)

    Rammah, Y. S.; Awad, E. M.

    2018-05-01

    Modifications of the optical properties of diallyl maleate-allyl diglycol carbonate (DAM-ADC) nuclear detector induced by alpha particles are described. DAM-ADC samples were irradiated perpendicularly by thin 241Am disk source that emits alpha particles with 5.48 MeV. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy. It was found that DAM-ADC polymer shows substantial modifications in its optical characteristics upon irradiated with alpha particles with different energies. The optical energy band gap (Egap) for the detector was calculated for the direct and the indirect allowed transitions in K-space using two approaches (Tauc's model and absorption spectrum fitting (ASF) method). Urbach's energy (Ea), number of carbon atoms per conjugated length (N), number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Results reveal that the values of energy gap in direct transition are greater than those of indirect, before and after irradiation. (Egap), (Ea), (N), (M), and (n) of the present samples are changed significantly with irradiation time and value of alpha energy. Results reflect the possibility of using DAM-ADC polymer track detectors to estimate alpha particle energies using the variation of the absorbance.

  6. Spectroscopic quantum imaging using pixel-level ADCS in Semiconductor-based Hybrid pixel detectors

    NARCIS (Netherlands)

    San Segundo Bello, D.

    2009-01-01

    This thesis describes the design of a microelectronic system that can be used to build a spectroscopic imaging system, in particular a spectroscopic quantum imaging using pixel-level ADCs in semiconductor-based hybrid pixel detectors. In such a system the signal generated in the sensor by a photon

  7. Studying DAC capacitor-array degradation in charge-redistribution SAR ADCs

    NARCIS (Netherlands)

    Khan, M.A.; Kerkhoff, Hans G.

    2014-01-01

    In this paper, system-level behavioural models are used to simulate the aging-related degradation effects in the DAC capacitor array of a charge-redistribution successive approximation register (SAR) ADC because of the large calculation time of transistor-level aging simulators. A

  8. Charge-sharing SAR ADCs for low-voltage low-power applications

    CERN Document Server

    Rabuske, Taimur

    2017-01-01

    This book introduces readers to the potential of charge-sharing (CS) successive approximation register (SAR) analog-to-digital converters (ADCs), while providing extensive analysis of the factors that limit the performance of the CS topology. The authors present guidelines and useful techniques for mitigating the limitations of the architecture, while focusing on the implementation under restricted power budgets and voltage supplies.

  9. DW-MRI of liver lesions: Can a single ADC-value represent the entire lesion?

    International Nuclear Information System (INIS)

    Schmid-Tannwald, C.; Dahi, F.; Jiang, Y.; Ivancevic, M.K.; Rist, C.; Sethi, I.; Oommen, J.; Oto, A.

    2014-01-01

    Aim: To evaluate whether focal liver lesions (FLLs) exhibit a homogeneous appearance on apparent diffusion coefficient (ADC) maps and whether there is inter-section variation in the calculated ADC values of FLLs (inter-section range). Materials and methods: Eighty-eight patients with 128 FLLs (70 benign, 58 malignant) who underwent abdominal magnetic resonance imaging (MRI) including diffusion-weighted (DW)-MRI were included. Two observers evaluated variation of signal intensity of each FLL within each ADC map image (intra-section) and among different ADC map images through the lesion (inter-section). ADC values of each FLL and neighbouring liver parenchyma were measured on all sections. The inter-section range of FLLs was compared with the neighbouring liver parenchyma. Results: Intra-section inhomogeneity was noted in 39.8% (97/244 sections) and 38.9% (95/244) of benign lesions, and 61% (114/187 sections) and 61.5% (115/187) of malignant lesions, by observer 1 and observer 2, respectively. Inter-section inhomogeneity was noted in 25.7% (18/70) and 27.1% (19/70) of benign lesions, and 51.7% (30/58) and 50% (29/58) of malignant lesions, by observer 1 and observer 2, respectively. The inter-section range for both benign (0.28 × 10 −3  mm²/s) and malignant (0.25 × 10 −3  mm²/s) FLLs were significantly greater than that of liver parenchyma surrounding benign (0.16 × 10 −3  mm²/s, p < 0.001) and malignant (0.14 × 10 −3  mm²/s, p = 0.01) FLLs. Conclusion: Due to intra-/inter-section variations in ADC values of benign and malignant FLLs, a single ADC value may not reliably represent the entire lesion

  10. Test vehicles for CMS HGCAL readout ASIC

    CERN Document Server

    Thienpont, Damien

    2017-01-01

    This paper presents first measurement results of two test vehicles ASIC embedding some building blocks for the future CMS High Granularity CALorimeter (HGCAL) read-out ASIC. They were fabricated in CMOS 130 nm, in order to first design the Analog and Mixed-Signal blocks before going to a complete and complex chip. Such a circuit needs to achieve low noise high dynamic range charge measurement and 20 ps resolution timing capability. The results show good analog performance but with higher noise levels compared to simulations. We present the results of the preamplifiers, shapers and ADCs.

  11. Comparison of the outcomes of dynamic/static tests and palpation tests in TMD-pain patients.

    Science.gov (United States)

    Osiewicz, M A; Manfredini, D; Loster, B W; van Selms, M K A; Lobbezoo, F

    2018-03-01

    In addition to palpation tests, dynamic/static tests have been proposed to complement temporomandibular disorders (TMD) patients' evaluation in the clinical setting. The aim of this study was to assess the intra- and inter-observer reliability of the palpation tests and of the dynamic/static tests, and to determine whether those tests would yield comparable outcomes in terms of pain diagnoses. Ninety-eight (N = 98) consecutive adult patients were examined during 2 clinical sessions by 2 independent examiners, based on muscle and joint palpation techniques described in the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). They also underwent dynamic/static tests. The intra-observer reliability of palpation tests was generally poor, with fair-to-good to excellent ICC values only for the superior masseter and intra-oral sites. The inter-observer reliability of palpation was fair-to-good for muscles, but it was poor for the TMJ lateral pole. Both intra- and inter-observer reliability for the dynamic/static tests varied from fair-to-good to excellent. The intra-observer reliability for muscle pain diagnoses based on palpation tests was between poor and fair-to-good, whereas the inter-observer reliability was excellent. The intra-observer reliability for pain diagnoses based on dynamic/static tests was fair-to-good, and the inter-observer reliability varied from fair-to-good to excellent. Some features of the dynamic/static tests make them potentially more useful than palpation tests for selected clinical purposes, such as discriminating between joint and muscle pain as well as monitoring symptoms course. Thus, findings from this investigation suggest that both tests should be included in the TMD diagnostic algorithms. © 2018 John Wiley & Sons Ltd.

  12. Testing of tunnel support : dynamic load testing of rockbolt elements to provide data for safer support design.

    CSIR Research Space (South Africa)

    Ortlepp, WD

    1998-06-01

    Full Text Available This research report discusses the development of a realistic and controllable method of testing support tendons dynamically, which has been achieved in this research project, offers a new and fresh opportunity for improving the design methodology...

  13. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  14. Advanced Gun System (AGS) Dynamic Characterization: Modal Test and Analysis, High-Frequency Analysis

    National Research Council Canada - National Science Library

    Berman, Morris

    1999-01-01

    Dynamic characterization tests were performed on the Advanced Gun System (AGS) vehicle. The tests were designed to provide modeling information for high-frequency shock prediction codes, as well as finite element codes...

  15. Dynamic rock tests using split Hopkinson (Kolsky bar system – A review

    Directory of Open Access Journals (Sweden)

    Kaiwen Xia

    2015-02-01

    Full Text Available Dynamic properties of rocks are important in a variety of rock mechanics and rock engineering problems. Due to the transient nature of the loading, dynamic tests of rock materials are very different from and much more challenging than their static counterparts. Dynamic tests are usually conducted using the split Hopkinson bar or Kolsky bar systems, which include both split Hopkinson pressure bar (SHPB and split Hopkinson tension bar (SHTB systems. Significant progress has been made on the quantification of various rock dynamic properties, owing to the advances in the experimental techniques of SHPB system. This review aims to fully describe and critically assess the detailed procedures and principles of techniques for dynamic rock tests using split Hopkinson bars. The history and principles of SHPB are outlined, followed by the key loading techniques that are useful for dynamic rock tests with SHPB (i.e. pulse shaping, momentum-trap and multi-axial loading techniques. Various measurement techniques for rock tests in SHPB (i.e. X-ray micro computed tomography (CT, laser gap gauge (LGG, digital image correlation (DIC, Moiré method, caustics method, photoelastic coating method, dynamic infrared thermography are then discussed. As the main objective of the review, various dynamic measurement techniques for rocks using SHPB are described, including dynamic rock strength measurements (i.e. dynamic compression, tension, bending and shear tests, dynamic fracture measurements (i.e. dynamic imitation and propagation fracture toughness, dynamic fracture energy and fracture velocity, and dynamic techniques for studying the influences of temperature and pore water.

  16. Dynamic test of radio altimeter based on IQ modulation

    Science.gov (United States)

    Pan, Hongfei; Tian, Yu; Li, Miao

    2010-08-01

    This paper based on the analysis and research of radio altimeter and its basic principles, it introduces a design for I/Q modulator's radio altimeter testing system. Further, data got from the test had been analyzed. Combined with the testing data of the altimeter, a construction of the I/Q modulator's radio altimeter testing system is built.

  17. Evaluation of dynamic testing of as-built civil engineering structures

    International Nuclear Information System (INIS)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1985-01-01

    This paper summarizes an evaluation of dynamic tests performed on large as-built structures. The objectives and methods (excitation and data analysis) of tests are reviewed. The utility and limitations of dynamic testing in light of actual experience is discussed. Though low-level tests in themselves will not be useful for predicting structural response to strong ground motion, they are useful for verifying linear models and for clarifying physical phenomena related to soil-structure interaction

  18. Quantum Dynamics of Test Particle in Curved Space-Time

    International Nuclear Information System (INIS)

    Piechocki, W.

    2002-01-01

    To reveal the nature of space-time singularities of removable type we examine classical and quantum dynamics of a free particle in the Sitter type spacetimes. Consider space-times have different topologies otherwise are isometric. Our systems are integrable and we present analytic solutions of the classical dynamics. We quantize the systems by making use of the group theoretical method: we find an essentially self-adjoint representation of the algebra of observables integrable to the irreducible unitarity representation of the symmetry group of each consider gravitational system. The massless particle dynamics is obtained in the zero-mass limit of the massive case. Global properties of considered gravitational systems are of primary importance for the quantization procedure. Systems of a particle in space-times with removable singularities appear to be quantizable. We give specific proposal for extension of our analysis to space-times with essential type singularities. (author)

  19. Making System Dynamics Cool II : New Hot Teaching and Testing Cases of Increasing Complexity

    NARCIS (Netherlands)

    Pruyt, E.

    2010-01-01

    This follow-up paper presents several actual cases for testing and teaching System Dynamics. The cases were developed between April 2009 and January 2010 for the Introductory System Dynamics courses at Delft University of Technology in the Netherlands. They can be used for teaching and testing

  20. Dynamic Testing : Measuring Inductive Reasoning in Children With Developmental Disabilities and Mild Cognitive Impairments

    NARCIS (Netherlands)

    Stevenson, C.E.; Resing, W.C.M.; Bosma, T.

    2012-01-01

    The main aim of this study was to evaluate the use of dynamic testing based on a graduated prompts techniques training in a clinical educational setting. We examined the question of whether it would be possible to administer a four session dynamic test to a specific group of children with complex

  1. Explanatory Item Response Modeling of Children's Change on a Dynamic Test of Analogical Reasoning

    Science.gov (United States)

    Stevenson, Claire E.; Hickendorff, Marian; Resing, Wilma C. M.; Heiser, Willem J.; de Boeck, Paul A. L.

    2013-01-01

    Dynamic testing is an assessment method in which training is incorporated into the procedure with the aim of gauging cognitive potential. Large individual differences are present in children's ability to profit from training in analogical reasoning. The aim of this experiment was to investigate sources of these differences on a dynamic test of…

  2. Measurement of Dynamic Viscoelasticity of Full-Size Wood Composite Panels Using a Vibration Testing Method

    Science.gov (United States)

    Cheng Guan; Houjiang Zhang; John F. Hunt; Lujing Zhou; Dan Feng

    2016-01-01

    The dynamic viscoelasticity of full-size wood composite panels (WCPs) under the free-free vibrational state were determined by a vibration testing method. Vibration detection tests were performed on 194 pieces of three types of full-size WCPs (particleboard, medium density fiberboard, and plywood (PW)). The dynamic viscoelasticity from smaller specimens cut from the...

  3. Structure-dynamic model verification calculation of PWR 5 tests

    International Nuclear Information System (INIS)

    Engel, R.

    1980-02-01

    Within reactor safety research project RS 16 B of the German Federal Ministry of Research and Technology (BMFT), blowdown experiments are conducted at Battelle Institut e.V. Frankfurt/Main using a model reactor pressure vessel with a height of 11,2 m and internals corresponding to those in a PWR. In the present report the dynamic loading on the pressure vessel internals (upper perforated plate and barrel suspension) during the DWR 5 experiment are calculated by means of a vertical and horizontal dynamic model using the CESHOCK code. The equations of motion are resolved by direct integration. (orig./RW) [de

  4. Diffusion weighted imaging of the uterus: regional ADC variation with oral contraceptive usage and comparison with cervical cancer.

    Science.gov (United States)

    Messiou, Christina; Morgan, Veronica A; De Silva, Sonali S; Ind, Thomas E; deSouza, Nandita M

    2009-07-01

    There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCP. A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (Puterus was significantly greater (Puterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging.

  5. Dynamic PMU Compliance Test under C37.118.1aTM-2014

    DEFF Research Database (Denmark)

    Ghiga, Radu; Wu, Qiuwei; Martin, K.

    2015-01-01

    This paper presents a flexible testing methodology and the dynamic compliance of PMUs as per the new C37.118.1a amendment published in 2014. The test platform consists of test signal generator, a Doble F6150 amplifier, PMUs under test, and a PMU test result analysis kit. The Doble amplifier is used...... for providing three phase voltage and current injections to the PMUs. Three PMUs from different vendors were tested simultaneously in order to provide a fair comparison of the devices. The new 2014 amendment comes with significant changes over the C37.118.1 - 2011 standard regarding the dynamic tests....

  6. Modeling Asteroid Dynamics using AMUSE: First Test Cases

    NARCIS (Netherlands)

    Frantseva, Kateryna; Mueller, Michael; van der Tak, Floris; Helmich, Frank P.

    2015-01-01

    We are creating a dynamic model of the current asteroid population. The goal is to reproduce measured impact rates in the current Solar System, from which we'll derive delivery rates of water and organic material by tracing low-albedo C-class asteroids (using the measured albedo distribution from

  7. Use and interpretation of the dynamic cone penetrometer (DCP) test

    CSIR Research Space (South Africa)

    Paige-Green, P

    2009-09-01

    Full Text Available During the early 1930's the California Bearing Ratio test (CBR) was developed for the testing of material strength in the laboratory for the design of pavements. The test involves the compaction of a potential road-building material into a standard...

  8. Value of ADC measurements for nodal staging after chemoradiation in locally advanced rectal cancer - a per lesion validation study

    Energy Technology Data Exchange (ETDEWEB)

    Lambregts, Doenja M.J.; Maas, Monique [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University Medical Centre, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, P.O. Box 616, Maastricht (Netherlands); Riedl, Robert G. [GROW School for Oncology and Developmental Biology, P.O. Box 616, Maastricht (Netherlands); Maastricht University Medical Centre, Department of Pathology, P.O. Box 5800, Maastricht (Netherlands); Bakers, Frans C.H.; Boetes, Carla; Beets-Tan, Regina G.H. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, P.O. Box 616, Maastricht (Netherlands); Verwoerd, Jan L. [MR Clinical Science Department, Philips Healthcare Benelux, P.O. Box 90050, Eindhoven (Netherlands); Kessels, Alfons G.H. [GROW School for Oncology and Developmental Biology, P.O. Box 616, Maastricht (Netherlands); Maastricht University Medical Centre, Department of Epidemiology, P.O. Box 5800, Maastricht (Netherlands); Lammering, Guido [GROW School for Oncology and Developmental Biology, P.O. Box 616, Maastricht (Netherlands); Maastro Clinic Maastricht, Radiation Oncology, P.O. Box 1588, Maastricht (Netherlands); Beets, Geerard L. [Maastricht University Medical Centre, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, P.O. Box 616, Maastricht (Netherlands)

    2011-02-15

    To evaluate the performance of diffusion-weighted MRI (DWI) in addition to T2-weighted (T2W) MRI for nodal restaging after chemoradiation in rectal cancer. Thirty patients underwent chemoradiation followed by MRI (1.5 T) and surgery. Imaging consisted of T2W-MRI and DWI (b0, 500, 1000). On T2W-MRI, nodes were scored as benign/malignant by two independent readers (R1, R2). Mean apparent diffusion coefficient (ADC) was measured for each node. Diagnostic performance was compared for T2W-MRI, ADC and T2W+ADC, using a per lesion histological validation. ADC was higher for the malignant nodes (1.43 {+-} 0.38 vs 1.19 {+-} 0.27 *10{sup -3} mm{sup 2}/s, p < 0.001). Area under the ROC curve/sensitivity/specificity were 0.88/65%/93% (R1) and 0.95/71%/91% (R2) using T2W-MRI; 0.66/53%/82% using ADC (mean of two readers); and 0.91/56%/98% (R1) and 0.96/56%/99% (R2) using T2W+ADC. There was no significant difference between T2W-MRI and T2W+ADC. Interobserver reproducibility was good for T2W-MRI ({kappa}0.73) and ADC (intraclass correlation coefficient 0.77). After chemoradiation, ADC measurements may have potential for nodal characterisation, but DWI on its own is not reliable. Addition of DWI to T2W-MRI does not improve accuracy and T2W-MRI is already sufficiently accurate. (orig.)

  9. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    International Nuclear Information System (INIS)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de; Ind, Thomas E.

    2009-01-01

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  10. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de (Cancer Research UK Clinical Magnetic Resonance Research Group, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)); Ind, Thomas E. (Dept. of Gynaecology and Obstetrics, St George' s Hospital NHS Trust, London (United Kingdom))

    2009-07-15

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  11. The Effects of Dynamic Assessment Procedures on Raven Matrices Performance, Visual Search Behavior, Test Anxiety and Test Orientation.

    Science.gov (United States)

    Bethge, Hans-Jorg; And Others

    1982-01-01

    Dynamic assessment procedures involving either verbalization or elaborated feedback lead to higher levels of Ravens Matrices performance, modified visual search behaviors, reduced test anxiety, and reduced negative orientations to the testing situation in third graders. Results are interpreted on offering construct validation to the assessment…

  12. Extensive test of an SU(3)-based partial dynamical symmetry

    International Nuclear Information System (INIS)

    Casten, R F

    2014-01-01

    The concept of symmetries pervades much of our understanding of nature. In nuclear structure, the IBA embodies a framework with three dynamical symmetries U(5), O(6) and SU(3). Of course, most nuclei break these symmetries. Leviatan has discussed a concept of Partial Dynamical Symmetry (PDS) in which the states of the ground and gamma bands, only, are exactly described by SU(3) while all others are not. With an E2 operator which is not a generator of SU(3), this PDS gives a parameter-free description of γ to ground band relative B(E2) values in 168 Er that is virtually identical to the best collective model (IBA) calculations with 2-3 parameters. We have carried out the first extensive study of this PDS, in 47 rare earth nuclei. Overall, the PDS works very well, and the deviations from the data are usually understandable in terms of specific kinds of mixing.

  13. Extensive Test of an SU(3)-based Partial Dynamical Symmetry

    Science.gov (United States)

    Casten, R. F.

    2014-09-01

    The concept of symmetries pervades much of our understanding of nature. In nuclear structure, the IBA embodies a framework with three dynamical symmetries U(5), O(6) and SU(3). Of course, most nuclei break these symmetries. Leviatan has discussed a concept of Partial Dynamical Symmetry (PDS) in which the states of the ground and gamma bands, only, are exactly described by SU(3) while all others are not. With an E2 operator which is not a generator of SU(3), this PDS gives a parameter-free description of γ to ground band relative B(E2) values in 168Er that is virtually identical to the best collective model (IBA) calculations with 2-3 parameters. We have carried out the first extensive study of this PDS, in 47 rare earth nuclei. Overall, the PDS works very well, and the deviations from the data are usually understandable in terms of specific kinds of mixing.

  14. Testing the Goodwin growth-cycle macroeconomic dynamics in Brazil

    Science.gov (United States)

    Moura, N. J.; Ribeiro, Marcelo B.

    2013-05-01

    This paper discusses the empirical validity of Goodwin’s (1967) macroeconomic model of growth with cycles by assuming that the individual income distribution of the Brazilian society is described by the Gompertz-Pareto distribution (GPD). This is formed by the combination of the Gompertz curve, representing the overwhelming majority of the population (˜99%), with the Pareto power law, representing the tiny richest part (˜1%). In line with Goodwin’s original model, we identify the Gompertzian part with the workers and the Paretian component with the class of capitalists. Since the GPD parameters are obtained for each year and the Goodwin macroeconomics is a time evolving model, we use previously determined, and further extended here, Brazilian GPD parameters, as well as unemployment data, to study the time evolution of these quantities in Brazil from 1981 to 2009 by means of the Goodwin dynamics. This is done in the original Goodwin model and an extension advanced by Desai et al. (2006). As far as Brazilian data is concerned, our results show partial qualitative and quantitative agreement with both models in the studied time period, although the original one provides better data fit. Nevertheless, both models fall short of a good empirical agreement as they predict single center cycles which were not found in the data. We discuss the specific points where the Goodwin dynamics must be improved in order to provide a more realistic representation of the dynamics of economic systems.

  15. Testing for time-varying loadings in dynamic factor models

    DEFF Research Database (Denmark)

    Mikkelsen, Jakob Guldbæk

    Abstract: In this paper we develop a test for time-varying factor loadings in factor models. The test is simple to compute and is constructed from estimated factors and residuals using the principal components estimator. The hypothesis is tested by regressing the squared residuals on the squared...... factors. The squared correlation coefficient times the sample size has a limiting chi-squared distribution. The test can be made robust to serial correlation in the idiosyncratic errors. We find evidence for factor loadings variance in over half of the variables in a dataset for the US economy, while...

  16. Full-Scale Dynamic Testing of Dolosse to Destruction

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    1981-01-01

    . The set up and the procedure of the tests, which simulate the impact from rocking of the units and from concrete pieces that are thrown against the units, are designed to make a comparison between the behaviour of units of different sizes possible. The test method is described and proposed as a standard...... exists. Different ways of improving the strength of the units are discussed on the basis of the results from tests with different types of concrete. The tests included an investigation of the influence of reinforcement, and of different types of concrete and surface cracks on the strength of the units....

  17. Test methods for the dynamic mechanical properties of polymeric materials. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Baker, G.K.

    1980-06-01

    Various test geometries and procedures for the dynamic mechanical analysis of polymers employing a mechanical spectrometer have been evaluated. The methods and materials included in this work are forced torsional pendulum testing of Kevlar/epoxy laminates and rigid urethane foams, oscillatory parallel plate testing to determine the kinetics of the cure of VCE with Hylene MP, oscillatory compressive testing of B-3223 cellular silicone, and oscillatory tensile testing of Silastic E and single Kevlar filaments. Fundamental dynamic mechanical properties, including the storage and loss moduli and loss tangent of the materials tested, were determined as a function of temperature and sometimes of frequency.

  18. Design of eight-channel ADC card for GHz signal conversion

    CERN Document Server

    Habib, Samer Bou; Jalmuzna, Wojciech; Jezynski, Tomasz

    2011-01-01

    This paper describes the design of an eight-channel ATCA card suited for direct analog-to-digital conversion of 1.3 GHz signals with a maximum ADC clock frequency of 500 MHz. The undersampling operation is used for signal conversion. This card was designed for the needs of the LLRF system of the FLASH and XFEL accelerators. The designed module consists of a main ATCA board with eight ADCs, FPGA unit, memory, power supply and diagnostic circuits. The main ATCA card allows connecting a daughter board with IPMI, CPU and fast interfaces for communication purposes. This paper describes such issues as system organization allowing acquisition of data at such high data rates, circuit synchronization by high-quality clock signals, CPU and connectivity features, 20-layer PCB design and techniques used for high-frequency signals transmission and matching.

  19. A second-order ΣΔ ADC using sputtered IGZO TFTs

    CERN Document Server

    Correia, Ana Paula Pinto; Goes, João Carlos da Palma

    2016-01-01

    This book discusses the design, electrical simulation and layout of a 2nd-order ∑∆ analog-to-digital converter (ADC), using oxide thin-film transistors (TFTs) technology. The authors provide a unified view of materials science and electronics engineering, in order to guide readers from both fields through key topics. To accomplish this goal, background regarding materials, device physics, characterization techniques, circuit design and layout is given together with a detailed discussion of experimental data. The final simulation results clearly demonstrate the potential of the proposed circuit-level techniques, which enables the implementation of robust and energy efficient ADCs based on oxide TFTs, for moderate resolutions and conversion-rates. Combines materials science and electronics engineering in the same book, making it possible to obtain a general overview, from TFTs production and characterization to their integration in relatively complex circuits; Adapts an a-Si:H TFT RPI model to simulate the ...

  20. Continuous time sigma delta ADC design and non-idealities analysis

    International Nuclear Information System (INIS)

    Yuan Jun; Chen Zhenhai; Yang Yintang; Zhang Zhaofeng; Wu Jun; Wang Chao; Qian Wenrong

    2011-01-01

    A wide bandwidth continuous time sigma delta ADC is implemented in 130 nm CMOS. A detailed non-idealities analysis (excess loop delay, clock jitter, finite gain and GBW, comparator offset and DAC mismatch) is performed developed in Matlab/Simulink. This design is targeted for wide bandwidth applications such as video or wireless base-stations. Athird-order continuous time sigma delta modulator comprises a third-order RC operational-amplifier-based loop filter and 3-bit internal quantizer operated at 512 MHz clock frequency. The sigma delta ADC achieves 60 dB SNR and 59.3 dB SNDR over a 16-MHz signal band at an OSR of 16. The power consumption of the CT sigma delta modulator is 22 mW from the 1.2-V supply. (semiconductor integrated circuits)

  1. An offset cancellation technique in a switched-capacitor comparator for SAR ADCs

    International Nuclear Information System (INIS)

    Tong Xingyuan; Zhu Zhangming; Yang Yintang

    2012-01-01

    An offset cancellation technique for a SAR (successive approximation register) ADC switched-capacitor comparator is described. The comparator is designed with a pre-amplifying and regenerative latching structure and realized in 0.18 μm CMOS. With the first stage preamplifier offset cancellation and low offset regenerative latching approach, the equivalent offset of the comparator is reduced to < 0.55 mV. By using the pre-amplifying and regenerative latching comparison mode the comparator exhibits low power dissipation. Under a 1.8 V power supply, with a 200 kS/s ADC sampling rate and 3 MHz clock frequency, a 13-bit comparison resolution is reached and less than 0.09 mW power dissipation is consumed. The superiority of this comparator is discussed and proved by the post-simulation and application to a 10 bit 200 kS/s touch screen SAR A/D converter. (semiconductor integrated circuits)

  2. ADC3 YANG DIBUAT DENGAN PELEBURAN ULANG ALUMINIUM BEKAS SEBAGAI BAHAN PROPELER KAPAL KAYU

    Directory of Open Access Journals (Sweden)

    Suyanto Suyanto

    2016-11-01

    Full Text Available Saat ini pembuatan propeler aluminium pada industri kecil banyak memanfaatkan bahan dasar aluminium bekas. Namun produk yang dihasilkan belum memenuhi spesifikasi standar material. Penelitian dilakukan dengan menggunakan bahan dasar aluminium siku bekas dan aluminium kampas bekas. Variasi penambahan TiB sebagai grain refiner dilakukan pada saat peleburan. Perhitungan dengan simulasi Excel dilakukan untuk memperkirakan komposisi hasil pengecoran yang sesuai. Pengecoran ulang menghasilkan produk dengan tingkat porositas 3,3 % sampai 5,9 %. Penggunaan cetakan pasir ikut berperan dalam timbulnya porositas. Penambahan TiB sebanyak 0,5% ke ADC3 berpengaruh pada penurunan ukuran butir hingga 50%, peningkatan kekerasan hingga 23%, peningkatan kekuatan tarik hingga 11%, serta penurunan keuletan hingga 20%. Kata kunci: ADC3, pengecoran ulang aluminium, propeler.

  3. Optimization of Modulator and Circuits for Low Power Continuous-Time Delta-Sigma ADC

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Bruun, Erik

    2014-01-01

    This paper presents a new optimization method for achieving a minimum current consumption in a continuous-time Delta-Sigma analog-to-digital converter (ADC). The method is applied to a continuous-time modulator realised with active-RC integrators and with a folded-cascode operational transconduc......- tance amplifier (OTA). Based on a detailed circuit analysis of the integrator and the OTA, key expression are derived relating the biasing current of the OTA to the noise requirements of the integrator. In the optimization the corner frequency of the modulator loop filter and the number of quantizer...... levels are swept. Based on the results of the circuit analysis, for each modulator combination the summed current consumption of the 1st integrator and quantizer of the ADC is determined. By also sweeping the partitioning of the noise power for the different circuit parts, the optimum modulator...

  4. Linearity Analysis on a Series-Split Capacitor Array for High-Speed SAR ADCs

    Directory of Open Access Journals (Sweden)

    Yan Zhu

    2010-01-01

    Full Text Available A novel Capacitor array structure for Successive Approximation Register (SAR ADC is proposed. This circuit efficiently utilizes charge recycling to achieve high-speed of operation and it can be applied to high-speed and low-to-medium-resolution SAR ADC. The parasitic effects and the static linearity performance, namely, the INL and DNL, of the proposed structure are theoretically analyzed and behavioral simulations are performed to demonstrate its effectiveness under those nonidealities. Simulation results show that to achieve the same conversion performance the proposed capacitor array structure can reduce the average power consumed from the reference ladder by 90% when compared to the binary-weighted splitting capacitor array structure.

  5. Unique Testing Capabilities of the NASA Langley Transonic Dynamics Tunnel, an Exercise in Aeroelastic Scaling

    Science.gov (United States)

    Ivanco, Thomas G.

    2013-01-01

    NASA Langley Research Center's Transonic Dynamics Tunnel (TDT) is the world's most capable aeroelastic test facility. Its large size, transonic speed range, variable pressure capability, and use of either air or R-134a heavy gas as a test medium enable unparalleled manipulation of flow-dependent scaling quantities. Matching these scaling quantities enables dynamic similitude of a full-scale vehicle with a sub-scale model, a requirement for proper characterization of any dynamic phenomenon, and many static elastic phenomena. Select scaling parameters are presented in order to quantify the scaling advantages of TDT and the consequence of testing in other facilities. In addition to dynamic testing, the TDT is uniquely well-suited for high risk testing or for those tests that require unusual model mount or support systems. Examples of recently conducted dynamic tests requiring unusual model support are presented. In addition to its unique dynamic test capabilities, the TDT is also evaluated in its capability to conduct aerodynamic performance tests as a result of its flow quality. Results of flow quality studies and a comparison to a many other transonic facilities are presented. Finally, the ability of the TDT to support future NASA research thrusts and likely vehicle designs is discussed.

  6. A new method for reducing DNL in nuclear ADCs using an interpolation technique

    International Nuclear Information System (INIS)

    Vaidya, P.P.; Gopalakrishnan, K.R.; Pethe, V.A.; Anjaneyulu, T.

    1986-01-01

    The paper describes a new method for reducing the DNL associated with nuclear ADCs. The method named the ''interpolation technique'' is utilized to derive the quantisation steps corresponding to the last n bits of the digital code by dividing quantisation steps due to higher significant bits of the DAC, using a chain of resistors. Using comparators, these quantisation steps are compared with the analog voltage to be digitized, which is applied as a voltage shift at both ends of this chain. The output states of the comparators define the n bit code. The errors due to offset voltages and bias currents of the comparators are statistically neutralized by changing the polarity of quantisation steps as well as the polarity of analog voltage (corresponding to last n bits) for alternate A/D conversion. The effect of averaging on the channel profile can be minimized. A 12 bit ADC was constructured using this technique which gives DNL of less than +-1% over most of the channels for conversion time of nearly 4.5 μs. Gatti's sliding scale technique can be implemented for further reduction of DNL. The interpolation technique has a promising potential of improving the resolution of existing 12 bit ADCs to 16 bit, without degrading the percentage DNL significantly. (orig.)

  7. A case of a resectable single hepatic epithelioid hemangioendothelioma with characteristic imaging by ADC map.

    Science.gov (United States)

    Okano, Hiroshi; Nakajima, Hideki; Tochio, Tomomasa; Suga, Daisuke; Kumazawa, Hiroaki; Isono, Yoshiaki; Tanaka, Hiroki; Matsusaki, Shimpei; Sase, Tomohiro; Saito, Tomonori; Mukai, Katsumi; Nishimura, Akira; Matsushima, Nobuyoshi; Baba, Youichirou; Murata, Tetsuya; Hamada, Takashi; Taoka, Hiroki

    2015-12-01

    A 47-year-old woman with a single-nodule hepatic tumor was referred to our hospital. She had no symptoms. The tumor was located at the surface of the right lobe of the liver; it showed peripheral low signal intensity on a magnetic resonance imaging apparent diffusion coefficient (ADC) map, and an influx of blood flow into the peripheral area of the tumor at the early vascular phase on perflubutane microbubble (Sonazoid(®)) contrast-enhanced (CE) ultrasonography. Since we suspected a malignant tumor, the patient underwent surgical resection. The hepatic tumor was resected curatively. Pathological examination revealed that the tumor was composed of epithelioid cells with an epithelioid structure and/or cord-like structure. Immunohistochemical staining was positive for cluster of differentiation 34 and factor VIII-related antigen. Based on the above, a final diagnosis of hepatic epithelioid hemangioendothelioma (EHE) was made. Hepatic EHE is a rare hepatic tumor: only a few cases of hepatic EHE with curative resection have been reported. We were unable to reach a diagnosis of hepatic EHE by imaging studies; however, an ADC map was useful in showing the malignant potential of the tumor, and CE ultrasonography was useful in revealing the peripheral blood flow of the tumor. When an unusual hepatic mass is encountered, hepatic EHE should be kept in mind, and the mass should be inspected with more than one imaging modality, including an ADC map, in the process of differential diagnosis.

  8. Real-time simulation based on a high-speed signal processing system VHS-ADC

    Science.gov (United States)

    Fu, Zhihong; Ma, Jing; Sun, Rui

    2006-11-01

    Real-time simulation for power electronics needs high-speed data processing and sampling, but most real-time simulation systems, such as dSPACE, can't meet the high-speed demands. Lyrtech's VHS-ADC, a high-speed signal processing system based on FPGA, is configured with multi-channels A/D, D/A and GPIO port, seamless interoperability with MATLAB, which has been applied widely in communication, audio, video and radar high-speed signal processing fields. However, VHS-ADC doesn't support real-time controller modeling. By constructing real-time control models including PI, PWM, Limiter and Reset-integrator model, this paper constructs a high-speed real-time simulation platform suitable for power electronics field. Further, the PWM-based Boost converter experiments prove the feasibility of real-time simulation by the rebuilt system, with Boost's switching frequency 100 kHz and its cycle 10μs. At frequency 100MHz, the corresponding simulation cycle is no more than 300ns, much less than switching cycle. Compared with TL494's waveform, it is proved that, as a novel way, VHS-ADC can support flexibly modeling process in real-time simulations with significant performance.

  9. Dynamic Object Oriented Requirements System (DOORS) System Test Plan

    International Nuclear Information System (INIS)

    JOHNSON, A.L.

    2000-01-01

    The U. S. Department of Energy, Office of River Protection (ORP) will use the Dynamic Object Oriented Requirements System (DOORS) as a tool to assist in identifying, capturing, and maintaining the necessary and sufficient set of requirements for accomplishing the ORP mission. By managing requirements as one integrated set, the ORP will be able to carry out its mission more efficiently and effectively. DOORS is a Commercial-Off-The-Shelf (COTS) requirements management tool. The tool has not been customized for the use of the PIO, at this time

  10. Diffusion-weighted imaging of breast lesions: Region-of-interest placement and different ADC parameters influence apparent diffusion coefficient values

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Helbich, Thomas H.; Baltzer, Pascal [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bogner, Wolfgang [Medical University Vienna - MR Center of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bago-Horvath, Zsuzsanna [Medical University Vienna, Department of Pathology, Vienna (Austria)

    2017-05-15

    To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p <.001). Minimum ADC showed the best diagnostic performance (AUC.928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC.85-.94) and inter-reader reproducibility (ICC.74-.94). Median measurement time was significantly shorter for the 2D ROIs (p <.001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. (orig.)

  11. Does a dynamic test of phonological awareness predict early reading difficulties?

    DEFF Research Database (Denmark)

    Gellert, Anna Steenberg; Elbro, Carsten

    2017-01-01

    A few studies have indicated that dynamic measures of phonological awareness may contribute uniquely to the prediction of early reading development. However, standard control measures have been few and limited by floor effects, thus limiting their predictive value. The purpose of the present study...... was to examine the predictive value of a dynamic test of phonological awareness while controlling for both letter knowledge and standard phonological awareness using measures with no floor effect. We administered a dynamic test of phonological awareness along with traditional tests of phonological awareness...... and letter knowledge to 160 children in the fall of kindergarten. Reading outcomes were studied at three test points: at the end of kindergarten, in the first half of Grade 1, and at the end of Grade 1. The results indicated that the dynamic test of phonological awareness contributed significantly...

  12. SiGe 130 nm-based Rad-Hard ADC for the JEO Mission, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop will demonstrate the feasibility of developing a radiation-hardened analog-to-digital converter (ADC) suitable for the Jupiter Europa Orbiter mission. This...

  13. Dynamic moduli and damping ratios of soil evaluated from pressuremeter test

    International Nuclear Information System (INIS)

    Yoshida, Yasuo; Ezashi, Yasuyuki; Kokusho, Takaji; Nishi, Yoshikazu

    1984-01-01

    Dynamic and static properties of soils are investigated using the newly developed equipment of in-situ test, which imposes dynamic repeated pressure on borehole wall at any depth covering a wide range of strain amplitude. This paper describes mainly the shear modulus and damping characteristics of soils obtained by using the equipment in several sites covering wide variety of soils. The test results are compared and with those obtained by other test methods such as the dynamic triaxial test, the simple shear test and the shear wave velocity test, and discussions are made with regard to their relation ships to each other, which demonstrates the efficiency of this in-situ test. (author)

  14. Applicability of laboratory data to large scale tests under dynamic loading conditions

    International Nuclear Information System (INIS)

    Kussmaul, K.; Klenk, A.

    1993-01-01

    The analysis of dynamic loading and subsequent fracture must be based on reliable data for loading and deformation history. This paper describes an investigation to examine the applicability of parameters which are determined by means of small-scale laboratory tests to large-scale tests. The following steps were carried out: (1) Determination of crack initiation by means of strain gauges applied in the crack tip field of compact tension specimens. (2) Determination of dynamic crack resistance curves of CT-specimens using a modified key-curve technique. The key curves are determined by dynamic finite element analyses. (3) Determination of strain-rate-dependent stress-strain relationships for the finite element simulation of small-scale and large-scale tests. (4) Analysis of the loading history for small-scale tests with the aid of experimental data and finite element calculations. (5) Testing of dynamically loaded tensile specimens taken as strips from ferritic steel pipes with a thickness of 13 mm resp. 18 mm. The strips contained slits and surface cracks. (6) Fracture mechanics analyses of the above mentioned tests and of wide plate tests. The wide plates (960x608x40 mm 3 ) had been tested in a propellant-driven 12 MN dynamic testing facility. For calculating the fracture mechanics parameters of both tests, a dynamic finite element simulation considering the dynamic material behaviour was employed. The finite element analyses showed a good agreement with the simulated tests. This prerequisite allowed to gain critical J-integral values. Generally the results of the large-scale tests were conservative. 19 refs., 20 figs., 4 tabs

  15. The Next Generation of High-Speed Dynamic Stability Wind Tunnel Testing (Invited)

    Science.gov (United States)

    Tomek, Deborah M.; Sewall, William G.; Mason, Stan E.; Szchur, Bill W. A.

    2006-01-01

    Throughout industry, accurate measurement and modeling of dynamic derivative data at high-speed conditions has been an ongoing challenge. The expansion of flight envelopes and non-conventional vehicle design has greatly increased the demand for accurate prediction and modeling of vehicle dynamic behavior. With these issues in mind, NASA Langley Research Center (LaRC) embarked on the development and shakedown of a high-speed dynamic stability test technique that addresses the longstanding problem of accurately measuring dynamic derivatives outside the low-speed regime. The new test technique was built upon legacy technology, replacing an antiquated forced oscillation system, and greatly expanding the capabilities beyond classic forced oscillation testing at both low and high speeds. The modern system is capable of providing a snapshot of dynamic behavior over a periodic cycle for varying frequencies, not just a damping derivative term at a single frequency.

  16. Proposed mixed-mode dynamic fracture toughness testing method using a new specimen

    Energy Technology Data Exchange (ETDEWEB)

    Wada, H.; Hinoshita, A. [Daido Institute of Technology, Nagoya (Japan); Calder, C.A.; Kennedy, T.C. [Oregon State Univ., Corvallis, OR (United States)

    1996-12-31

    To find a simple and highly accurate testing method for determining the mixed-mode dynamic fracture toughness in a wide range of ratio of opening and sliding modes, the authors applied a combination technique using an electrical resistance strain gage method and a dynamic finite element method (FEM) to determine the mixed-mode dynamic fracture toughness. They used measuring and recording devices associated with an impact fracture apparatus based on an air gun. The impact fracture test was conducted to assess the mixed-mode dynamic fracture toughness testing method under single-point bending for three specimens of polymethyl methacrylate (PMMA). The ratio of the opening mode deformation to the sliding mode can be changed by adjusting the hitting point. To measure a dynamic stress intensity factors (SIF) K{sub 1}(t) and a crack initiation time, a single axis strain gage was mounted in the vicinity of the crack tip.

  17. The changes of 18F-FDG uptake and ADC value of the normal endometrium during the menstrual cycle

    International Nuclear Information System (INIS)

    Seko, Ayumi; Kanasaki, Shuzou; Kitahara, Sawako; Murata, Kiyoshi; Tatsumi, Mitsuaki; Hayashida, Kohei; Sakashita, Yoko; Hamanaka, Yasuyo

    2007-01-01

    We evaluated the normal endometrium of reproductive age using positron emission tomography (PET)/CT and Diffusion-weighted MR imaging. 18 F-fluorodeoxyglucose (FDG) uptake and apparent diffusion coefficient (ADC) value were classified according to the menstrual cycle. On PET/CT, FDG uptake was significant high at the menstrual and ovulatory phase. On diffusion-weighted imaging (DWI), ADC value was significant low at the menstrual phase. (author)

  18. Diagnosis of early sacroiliitis in seronegative spondyloarthropathies by DWI and correlation of clinical and laboratory findings with ADC values

    International Nuclear Information System (INIS)

    Gezmis, Esin; Donmez, Fuldem Y.; Agildere, Muhtesem

    2013-01-01

    Purpose: Sacroiliitis is one of the diagnostic criteria of seronegative SpA. The purpose of our study is to show the signal characteristics of the sacral and iliac surfaces by DWI which may contribute in early diagnosis of sacroiliitis and investigate the correlation between ADC values and clinical and laboratory parameters. Materials and methods: 62 patients with inflammatory low back pain, with a history or suspect of seronegative SpA are enrolled into the study. 40 age and sex-matched subjects without SpA constituted the control group. After obtaining routine T1 and T2 weighted sequences, echo planar imaging at b values of 0, 400 and 800 was performed. ADC values on both surfaces of the both sacroiliac joints were measured in all subjects. The CRP and sedimentation results and the presence of arthritis and enthesitis were also correlated with the ADC values. Results: ADC values on both surfaces of the both sacroiliac joints were found 0.23 × 10 −3 mm 2 /sn in the control group. In the patient group, mean ADC value of 0.48 × 10 −3 mm 2 /sn was obtained (p < 0.001), which was statistically significant, compatible with the increased diffusion due to medullary edema in early sacroiliitis. There was a slight correlation between CRP and ADC values; presumed to be showing the relation between the activity of the disease and the active inflammation on DWI. There was no correlation between arthritis and enthesitis and the ADC values (p > 0.001). Conclusion: DWI, by measuring ADC values, adds significant information in the early diagnosis of sacroiliitis and may help to evaluate the efficiency of the treatment

  19. Diagnosis of early sacroiliitis in seronegative spondyloarthropathies by DWI and correlation of clinical and laboratory findings with ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gezmis, Esin; Donmez, Fuldem Y., E-mail: fuldemyildirim@yahoo.com; Agildere, Muhtesem

    2013-12-01

    Purpose: Sacroiliitis is one of the diagnostic criteria of seronegative SpA. The purpose of our study is to show the signal characteristics of the sacral and iliac surfaces by DWI which may contribute in early diagnosis of sacroiliitis and investigate the correlation between ADC values and clinical and laboratory parameters. Materials and methods: 62 patients with inflammatory low back pain, with a history or suspect of seronegative SpA are enrolled into the study. 40 age and sex-matched subjects without SpA constituted the control group. After obtaining routine T1 and T2 weighted sequences, echo planar imaging at b values of 0, 400 and 800 was performed. ADC values on both surfaces of the both sacroiliac joints were measured in all subjects. The CRP and sedimentation results and the presence of arthritis and enthesitis were also correlated with the ADC values. Results: ADC values on both surfaces of the both sacroiliac joints were found 0.23 × 10{sup −3} mm{sup 2}/sn in the control group. In the patient group, mean ADC value of 0.48 × 10{sup −3} mm{sup 2}/sn was obtained (p < 0.001), which was statistically significant, compatible with the increased diffusion due to medullary edema in early sacroiliitis. There was a slight correlation between CRP and ADC values; presumed to be showing the relation between the activity of the disease and the active inflammation on DWI. There was no correlation between arthritis and enthesitis and the ADC values (p > 0.001). Conclusion: DWI, by measuring ADC values, adds significant information in the early diagnosis of sacroiliitis and may help to evaluate the efficiency of the treatment.

  20. Dynamic MTF, an innovative test bench for detector characterization

    Science.gov (United States)

    Emmanuel, Rossi; Raphaël, Lardière; Delmonte, Stephane

    2017-11-01

    PLEIADES HR are High Resolution satellites for Earth observation. Placed at 695km they reach a 0.7m spatial resolution. To allow such performances, the detectors are working in a TDI mode (Time and Delay Integration) which consists in a continuous charge transfer from one line to the consecutive one while the image is passing on the detector. The spatial resolution, one of the most important parameter to test, is characterized by the MTF (Modulation Transfer Function). Usually, detectors are tested in a staring mode. For a higher level of performances assessment, a dedicated bench has been set-up, allowing detectors' MTF characterization in the TDI mode. Accuracy and reproducibility are impressive, opening the door to new perspectives in term of HR imaging systems testing.

  1. Advanced test methods for SRAMs: effective solutions for dynamic fault detection in nanoscaled technologies

    National Research Council Canada - National Science Library

    Bosio, Alberto

    2010-01-01

    ... for Dynamic Faults in SRAM MemoriesAdvanced Test Solutions for Dynamic Faults in SRAM Memories Authors of the book: Alberto Bosio, Associate Professor, LIRMM/University of Montpellier - France Luigi Dilillo, CNRS Researcher, LIRMM/CNRS - France Patrick Girard, CNRS Research Director, LIRMM/CNRS - France Serge Pravossoudovitch, Professor, LI...

  2. Dynamic testing of young children with (severe) disabilities : Presentation as part of symposium: Dynamic testing in children – language and speech problems or developmental disorders

    NARCIS (Netherlands)

    Visser, Linda

    2015-01-01

    A main disadvantage of static tests is that they do not take into account differences between children in chances they have had to learn and develop. Dynamic assessment is a way to take into account these differences and assess which skills a child can learn in which speed and which support it needs

  3. Desain Layout 1-Stage ADC Pipeline 80Msps dengan Mentor Graphics 0,35µm untuk Aplikasi Kamera Kecepatan Tinggi

    Directory of Open Access Journals (Sweden)

    Hamzah Afandi

    2012-10-01

    Full Text Available Design layout 1-stage pipeline is part of the 8-stage pipeline 80 Msps ADC. Layout 1-stage pipeline consists of 3 units : op-amp, switch capacitor, precision comparator with latch. Pipeline ADC works gradually and requires synchronization of digital output 8 stage by using a unit delay circuit (D-FF. Pipeline ADC requires pulse rate (clockgenerator to support its work. Units OP-AMP transconductance CMOS components designed with the correct specification ADC applications with capacitive loads, with a large input impedance and minimize noise. The precision comparator has Vos(offset voltage approximately equal to 0V. The capacitor switch designs use NMOS switch as a switch for the sampling and multiplying. In the sampling phase and multiplying processes, the ADC requires a clock pulse with a non-intersect mode (lapping. The width of non-overlapping period was adjusted to the time of constance in the sampling process and multiplying. The total number of each pulse period equal to 12.5 ns or equal to the frequency of 80MHz. In the 1-stage layout an additional correction capacitor was required to correct residual voltage. The total area of the layout 1-stage pipeline ADC is 1-bit 200 μm x 98μm.

  4. Dynamics of relative motion of test particles in general relativity

    International Nuclear Information System (INIS)

    Bazanski, S.L.

    1977-01-01

    Several variational principles which lead to the first and the second geodesic deviation equations, recently formulated by the author and used for the description of the relative motion of test particles in general relativity are presented. Relations between these principles are investigated and exhibited. The Hamilton-Jacobi equation is also studied for these generalized deviations and the conservation laws appearing here are discussed

  5. Dynamic GnRH and hCG testing

    DEFF Research Database (Denmark)

    Bang, A Kirstine; Nordkap, Loa; Almstrup, Kristian

    2017-01-01

    OBJECTIVE: Gonadotropin-releasing hormone (GnRH) and human chorionic gonadotropin (hCG) stimulation tests may be used to evaluate the pituitary and testicular capacity. Our aim was to evaluate changes in follicular-stimulating hormone (FSH), luteinizing hormone (LH) and testosterone after Gn......RH and hCG stimulation in healthy men and assess the impact of six single nucleotide polymorphisms on the responses. DESIGN: GnRH and hCG stimulation tests were performed on 77 healthy men, 18-40 years (reference group) at a specialized andrology referral center at a university hospital. The potential......: For the reference group, LH and FSH increased almost 400% and 40% during GnRH testing, stimulated levels varied from 4.4 to 58.8 U/L and 0.2 to 11.8 U/L and FSH decreased in nine men. Testosterone increased approximately 110% (range: 18.7-67.6 nmol/L) during hCG testing. None of the polymorphisms had any major...

  6. Rail-car impact tests with steel coil: collision dynamics

    Science.gov (United States)

    2003-04-22

    Two full-scale oblique grade-crossing impact tests were conducted in June 2002 to compare the crashworthiness performance of alternative corner post designs on rail passenger cab cars. On June 4, 2002 a cab car fitted with an end structure built to p...

  7. Coastal Ocean Ecosystem Dynamics Imager Pointing Line-of-Sight Solution Development and Testing

    Data.gov (United States)

    National Aeronautics and Space Administration — A stable pointing line of sight solution is developed and tested in support of the Coastal Ocean Ecosystem Dynamics Imager for the GEOstationary Coastal and Air...

  8. Safety of railroad passenger vehicle dynamics : OMNISIM simulation and test correlations for passenger rail cars

    Science.gov (United States)

    2002-07-01

    The purpose of the work is to validate the safety assessment methodology previously developed for passenger rail vehicle dynamics, which requires the application of simulation tools as well as testing of vehicles under different track scenarios. This...

  9. Comparison of interior crashworthiness observed in passenger train accidents and 8G dynamic seat sled tests

    Science.gov (United States)

    2012-04-17

    The Office of Research and Development of the Federal Railroad Administration conducts engineering research to address protection of passengers and crew during train accidents. This research includes accident investigations and dynamic seat testing t...

  10. A coverage metric to evaluate tests for continuous-time dynamic systems

    Science.gov (United States)

    Skruch, Paweł

    2011-06-01

    We present a test quality measure that allows for quantifying the completeness of black-box tests for continuous-time dynamic systems. The measure is based on a state space model of the system under test. The metric has been called the state space coverage. The classical coverage metrics, such as statement, branch, and path coverage, are not appropriate for dynamic systems because such systems are defined by differential equations and usually have an infinite number of states. The objective of the paper is to develop a necessary foundation for the metric as well as to present guidance on its application to software systems that incorporate dynamic behavior. The purpose of the proposed solution is to better assure the test engineer that a given test set is sufficient and to indicate where additional testing is required. An application example is presented to illustrate theoretical analysis and mathematical formulation.

  11. Test of Cable Products in Respect of Thermal and Dynamic Stability

    Directory of Open Access Journals (Sweden)

    M. A. Коrotkevich

    2010-01-01

    Full Text Available The paper considers conditions for selection of  power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used.

  12. ADC border effect and suppression of quantization error in the digital dynamic measurement

    Science.gov (United States)

    Bai, Li-Na; Liu, Hai-Dong; Zhou, Wei; Zhang, Yong; Zhai, Hong-Qi; Cui, Zhen-Jian; Zhao, Ming-Ying; Gu, Xiao-Qian; Liu, Bei-Ling; Huang, Li-Bei

    2017-08-01

    Not Available Project supported by the National Natural Science Foundation of China (Grant Nos. 10978017 and 61201288), Shaanxi Natural Science Foundation Research Plan Projects, China (Grant No. 2014JM2-6128), and Shaanxi Major Technological Achievements Transformation and Guidance Special Projects, China (Grant No. 2015KTCG01-01).

  13. Development of structural health monitoring techniques using dynamics testing

    Energy Technology Data Exchange (ETDEWEB)

    James, G.H. III [Sandia National Labs., Albuquerque, NM (United States). Experimental Structural Dynamics Dept.

    1996-03-01

    Today`s society depends upon many structures (such as aircraft, bridges, wind turbines, offshore platforms, buildings, and nuclear weapons) which are nearing the end of their design lifetime. Since these structures cannot be economically replaced, techniques for structural health monitoring must be developed and implemented. Modal and structural dynamics measurements hold promise for the global non-destructive inspection of a variety of structures since surface measurements of a vibrating structure can provide information about the health of the internal members without costly (or impossible) dismantling of the structure. In order to develop structural health monitoring for application to operational structures, developments in four areas have been undertaken within this project: operational evaluation, diagnostic measurements, information condensation, and damage identification. The developments in each of these four aspects of structural health monitoring have been exercised on a broad range of experimental data. This experimental data has been extracted from structures from several application areas which include aging aircraft, wind energy, aging bridges, offshore structures, structural supports, and mechanical parts. As a result of these advances, Sandia National Laboratories is in a position to perform further advanced development, operational implementation, and technical consulting for a broad class of the nation`s aging infrastructure problems.

  14. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  15. Application of Structural Dynamic Response Optimization to Design of Shock Test Fixtures

    International Nuclear Information System (INIS)

    Mao, Yongjian; Zhu, Changchun; Wang, Qilu; Yan, Yuan

    2002-01-01

    In shock tests, acceleration loads are required to be imposed on test-pieces with minimum distortion, which leads to the vital importance of the dynamic characteristics of fixtures. As most shock test fixtures are made based on the empirical design presently, which are hard to estimate the dynamic characteristics, a proposition is presented for design of shock test fixture with are hard to estimate the dynamic characteristics, a proposition is presented for design of shock test fixtures with the application of structural dynamic response optimization. In this way, the integrated system of test-piece and fixtures with the is considered to be 'a black box', and only the acceleration response at the joint point demonstrates the least difference between the actual response and the anticipate response. Besides, the solution method of structural dynamic response optimization is given, where, the finite element method is used to computing the structural dynamic response and the Subproblem Approximation Method is introduced to minimizing of the objective function. Furthermore, an optimum design of a typical fixture is made as an example. According the analysis, the results are reasonable, the optimum model is correct and the method is proved efficient and feasible

  16. Validation of programmable industrial automation systems for safety critical applications in NPP's dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems can not totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. The prototype dynamic testing harness for programmable digital systems developed at the Technical Research Centre of Finland (VTT) is described in the presentation. (12 refs., 2 figs., 2 tabs.)

  17. Validation of programmable industrial automation systems for safety critical applications in NPP's; dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems cannot be totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. This paper describes a prototype dynamic testing harness for programmable digital systems developed at VTT. (author). 12 refs, 2 figs, 2 tabs

  18. Gas Dynamic Spray Technology Demonstration Project Management. Joint Test Report

    Science.gov (United States)

    Lewis, Pattie

    2011-01-01

    The standard practice for protecting metallic substrates in atmospheric environments is the use of an applied coating system. Current coating systems used across AFSPC and NASA contain volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). These coatings are sUbject to environmental regulations at the Federal and State levels that limit their usage. In addition, these coatings often cannot withstand the high temperatures and exhaust that may be experienced by Air Force Space Command (AFSPC) and NASA structures. In response to these concerns, AFSPC and NASA have approved the use of thermal spray coatings (TSCs). Thermal spray coatings are extremely durable and environmentally friendly coating alternatives, but utilize large cumbersome equipment for application that make the coatings difficult and time consuming to repair. Other concerns include difficulties coating complex geometries and the cost of equipment, training, and materials. Gas Dynamic Spray (GOS) technology (also known as Cold Spray) was evaluated as a smaller, more maneuverable repair method as well as for areas where thermal spray techniques are not as effective. The technology can result in reduced maintenance and thus reduced hazardous materials/wastes associated with current processes. Thermal spray and GOS coatings also have no VOCs and are environmentally preferable coatings. The primary objective of this effort was to demonstrate GDS technology as a repair method for TSCs. The aim was that successful completion of this project would result in approval of GDS technology as a repair method for TSCs at AFSPC and NASA installations to improve corrosion protection at critical systems, facilitate easier maintenance activity, extend maintenance cycles, eliminate flight hardware contamination, and reduce the amount of hazardous waste generated.

  19. Six-Degree-of-Freedom Dynamic Test System (SDTS) User Test Planning Guide

    Science.gov (United States)

    Stokes, LeBarian

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the SDTS. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  20. Dynamic instrumentation for the K-1600 seismic test facility recommissioning

    International Nuclear Information System (INIS)

    VanHoy, B.W.

    1991-01-01

    Martin Marietta Energy Systems, Inc. is the site contractor to the Department of Energy (DOE) for three Oak Ridge, Tennessee sites, the site in Portsmouth, Ohio, and the site in Paducah, Kentucky. To provide a focus for all natural phenomena engineering related problems, Martin Marietta Energy Systems, Inc. established the Center for Natural Phenomena Engineering under the technical direction of Dr. James E. Beavers. One of the Center's mandates is the determination of seismic properties of building structures containing sensitive processes. This has led to the recommissioning of the K-1600 Seismic Test Facility. The biaxial shake table in this facility was constructed during the eighties for seismic qualification of equipment of the Gas Centrifuge Enrichment Plant. After construction of the plant was terminated the Seismic Test Facility was placed in standby where it was left for six years. The facility's original instrumentation was evaluated versus the required instrumentation to augment its new expanded mission parameters. Instrumentation selection involving technology changes, age and attrition, and the new mission goals are discussed in this paper along with the rationale and budget that were involved with each decision. The testing potential of this facility along with the instrumentation upgrades necessary to accomplish these new tasks for the Center for Natural Phenomena Engineering are considered. New uses such as seismic qualification of equipment utilized in DOE's missions at various sites and waste treatment are proposed. This instrumentation selection is discussed in detail to show the rationale and proposed used of the facility as well as the capabilities of this DOE resource

  1. Dynamic-range tests for a gamma-ray sensor

    International Nuclear Information System (INIS)

    Byrd, R.C.; Longmire, J.L.; Moss, C.E.

    1995-01-01

    The task of detecting and characterizing intense bursts of nuclear radiation requires an instrument capable of operating reliably over wide extremes of signal intensity. Developing techniques for testing and calibrating such a detector involves a combination of experimental measurements, data analyses, and computer simulations. The results of these efforts provide important insight into the instrument's behavior in the laboratory and in its eventual application. For the present case, such studies not only verify the proper operation of the existing detector, but they also provide the basis for future improvements in its performance

  2. Dynamic fatigue testing of Zerodur glass-ceramic

    Science.gov (United States)

    Tucker, Dennis S.

    1988-01-01

    The inherent brittleness of glass invariably leads to a large variability in strength data and a time dependence in strength. Leading rate plays a large role in strength values. Glass is found to be weaker when supporting loads over long periods of time as compared to glass which undergoes rapid leading. These properties complicate the structural design allowables for the utilization of glass components in an application such as Advanced X-ray Astrophysics Facility (AXAF). The test methodology to obtain parameters which can be used to predict the reliability and life time of Zerodur glass-ceramic which is to be used for the mirrors in the AXAF is described.

  3. Dynamic metrology and data processing for precision freeform optics fabrication and testing

    Science.gov (United States)

    Aftab, Maham; Trumper, Isaac; Huang, Lei; Choi, Heejoo; Zhao, Wenchuan; Graves, Logan; Oh, Chang Jin; Kim, Dae Wook

    2017-06-01

    Dynamic metrology holds the key to overcoming several challenging limitations of conventional optical metrology, especially with regards to precision freeform optical elements. We present two dynamic metrology systems: 1) adaptive interferometric null testing; and 2) instantaneous phase shifting deflectometry, along with an overview of a gradient data processing and surface reconstruction technique. The adaptive null testing method, utilizing a deformable mirror, adopts a stochastic parallel gradient descent search algorithm in order to dynamically create a null testing condition for unknown freeform optics. The single-shot deflectometry system implemented on an iPhone uses a multiplexed display pattern to enable dynamic measurements of time-varying optical components or optics in vibration. Experimental data, measurement accuracy / precision, and data processing algorithms are discussed.

  4. On quantum effects in the dynamics of macroscopic test masses

    International Nuclear Information System (INIS)

    Mueller-Ebhardt, Helge

    2009-01-01

    This thesis provides theoretically a link between the increase of the sensitivity of gravitational-wave detectors and the possibility of preparing macroscopic quantum states in such detectors. In the first part of this thesis, we theoretically explore the quantum measurement noise of an optical speed meter topology, the Sagnac interferometer, equipped with an additional detuned cavity at the output port. This detuned signal-recycling technique was already investigated when applying it to a Michelson interferometer and is used in the gravitational-wave detector GEO600. Together with the quantum noise analysis of the simple Sagnac interferometer, it is the basis of our study: we optimize the Sagnac interferometer's sensitivity towards the detection of a certain gravitational-wave source in the vicinity of a realistic classical noise environment. Motivated by the fact that the Michelson interferometer, as a position meter, with detuned signal-recycling can transduce the gravitational-wave strain into real mirror motion, we compare the transducer effect in a speed and in a position meter. Furthermore, we theoretically investigate the conditional output squeezing of a cavity which is detuned with respect to its carrier and its subcarrier. Therewith we pursue the theoretical analysis of the ponderomotive squeezer. With the knowledge gained in the first part about the quantum measurement process in laser interferometers, the second part of this thesis comprises a theoretical analysis of the conditonal state in positon and momentum of the interferometer's test masses. We motivate not to obtain the conditional states from a stochastic master equation but with the help of the so-called Wiener filtering method. Using this method, we calculate the most general expression for the conditional covariance matrix of the Gaussian state of a test mass under any linear Markovian measurement process. Then we specify to the interferometry and theoretically show under which circumstances

  5. The Shock and Vibration Bulletin. Part 2. Model Test and Analysis, Testing Techniques, Machinery Dynamics, Isolation and Damping, Structural Dynamics

    Science.gov (United States)

    1986-08-01

    jBfr 5? JOR JS T SIONAL/lBRATIONjerF^EAR-RANCHED PROPULSION.gVSTEMS j... 117 / H.F. Tavares, Cepstrum Engenharia Ltda., Rio de Janeiro, Brazil and V...GAUGE" FOR STRUCTURAL ASSESSMENT T. Krauthammer, Department ot Civil and Mineral Engineering, University of Minnesota, Minneapolis, MN ACTIVE ONE...ACCEPTANCE TEST SPECIFICATIONS FOR BLAST-RESISTANT WINDOWS G.E. Meyers, Naval Civil Engineering Laboratory, Port Hueneme, CA Shock Testin» and

  6. ADC histograms predict response to anti-angiogenic therapy in patients with recurrent high-grade glioma

    Energy Technology Data Exchange (ETDEWEB)

    Nowosielski, Martha; Tinkhauser, Gerd; Stockhammer, Guenther [Innsbruck Medical University, Department of Neurology, Innsbruck (Austria); Recheis, Wolfgang; Schocke, Michael; Gotwald, Thaddaeus [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Goebel, Georg [Innsbruck Medical University, Department of Medical Statistics, Informatics and Health Economics, Innsbruck (Austria); Gueler, Oezguer [Innsbruck Medical University, 4D Visualization Laboratory, University Clinic of Oto-, Rhino- and Laryngology, Innsbruck (Austria); Kostron, Herwig [Innsbruck Medical University, Department of Neurosurgery, Innsbruck (Austria); Hutterer, Markus [Innsbruck Medical University, Department of Neurology, Innsbruck (Austria); Paracelsus Medical University Salzburg-Christian Doppler Hospital, Department of Neurology, Salzburg (Austria)

    2011-04-15

    The purpose of this study is to evaluate apparent diffusion coefficient (ADC) maps to distinguish anti-vascular and anti-tumor effects in the course of anti-angiogenic treatment of recurrent high-grade gliomas (rHGG) as compared to standard magnetic resonance imaging (MRI). This retrospective study analyzed ADC maps from diffusion-weighted MRI in 14 rHGG patients during bevacizumab/irinotecan (B/I) therapy. Applying image segmentation, volumes of contrast-enhanced lesions in T1 sequences and of hyperintense T2 lesions (hT2) were calculated. hT2 were defined as regions of interest (ROI) and registered to corresponding ADC maps (hT2-ADC). Histograms were calculated from hT2-ADC ROIs. Thereafter, histogram asymmetry termed ''skewness'' was calculated and compared to progression-free survival (PFS) as defined by the Response Assessment Neuro-Oncology (RANO) Working Group criteria. At 8-12 weeks follow-up, seven (50%) patients showed a partial response, three (21.4%) patients were stable, and four (28.6%) patients progressed according to RANO criteria. hT2-ADC histograms demonstrated statistically significant changes in skewness in relation to PFS at 6 months. Patients with increasing skewness (n = 11) following B/I therapy had significantly shorter PFS than did patients with decreasing or stable skewness values (n = 3, median percentage change in skewness 54% versus -3%, p = 0.04). In rHGG patients, the change in ADC histogram skewness may be predictive for treatment response early in the course of anti-angiogenic therapy and more sensitive than treatment assessment based solely on RANO criteria. (orig.)

  7. A 12-bit SAR ADC integrated on a multichannel silicon drift detector readout IC

    International Nuclear Information System (INIS)

    Schembari, F.; Bellotti, G.; Fiorini, C.

    2016-01-01

    A 12-bit analog-to-digital converter (ADC) addressed to Silicon-Drift Detectors (SDDs) multichannel readout ASICs for X- and gamma-ray applications is presented. Aiming at digitizing output multiplexed data from the upstream analog filters banks, the converter must ensure 11-bit accuracy and a sampling frequency of about 5 MS/s. The ADC architecture is the charge-redistribution (CR) successive-approximation register (SAR). A fully differential topology has also been chosen for better rejection of common-mode noise and disturbances. The internal DAC is made of binary-scaled capacitors, whose bottom plates are switched by the SAR logic to perform the binary search of the analog input value by means of the monotonic switching scheme. The A/D converter is integrated on SFERA, a multichannel ASIC fabricated in a standard CMOS 0.35 μm 3.3 V technology and it occupies an area of 0.42 mm 2 . Simulated static performance shows monotonicity over the whole input–output characteristic. The description of the circuit topology and of inner blocks architectures together with the experimental characterization is here presented. - Highlights: • X- and γ-ray spectroscopy front-ends need to readout a high number of detectors. • Design efforts are increasingly oriented to compact and low-power ASICs. • A possible solution is the on-chip integration of the analog-to-digital converter. • A 12-bit CR successive-approximation-register ADC has been developed. • It is a suitable candidate as the digitizer to be integrated in multichannel ASICs

  8. An improved dynamic test method for solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector...... parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content...... for the second-order differential term with 6–9min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87W/m2 and 5.22W/m2...

  9. Final report of fuel dynamics Test E7

    International Nuclear Information System (INIS)

    Doerner, R.C.; Murphy, W.F.; Stanford, G.S.; Froehle, P.H.

    1977-04-01

    Test data from an in-pile failure experiment of high-power LMFBR-type fuel pins in a simulated $3/s transient-overpower (TOP) accident are reported and analyzed. Major conclusions are that (1) a series of cladding ruptures during the 100-ms period preceding fuel release injected small bursts of fission gas into the flow stream; (2) gas release influenced subsequent cladding melting and fuel release [there were no measurable FCI's (fuel-coolant interactions), and all fuel motion observed by the hodoscope was very slow]; (3) the predominant postfailure fuel motion appears to be radial swelling that left a spongy fuel crust on the holder wall; (4) less than 4 to 6 percent of the fuel moved axially out of the original fuel zone, and most of this froze within a 10-cm region above the original top of the fuel zone to form the outlet blockage. An inlet blockage approximately 1 cm long was formed and consisted of large interconnected void regions. Both blockages began just beyond the ends of the fuel pellets

  10. Dynamic Impact Analyses and Tests of Concrete Overpacks - 13638

    International Nuclear Information System (INIS)

    Lee, Sanghoon; Cho, Sang-Soon; Kim, Ki-Young; Jeon, Je-Eon; Seo, Ki-Seog

    2013-01-01

    Concrete cask is an option for spent nuclear fuel interim storage which is prevailingly used in US. A concrete cask usually consists of metallic canister which confines the spent nuclear fuel and concrete overpack. When the overpack undergoes a severe missile impact which might be caused by a tornado or an aircraft crash, it should sustain acceptable level of structural integrity so that its radiation shielding capability and the retrievability of canister are maintained. Missile impact against a concrete overpack involves two damage modes, local damage and global damage. Local damage of concrete is usually evaluated by empirical formulas while the global damage is evaluated by finite element analysis. In many cases, those two damage modes are evaluated separately. In this research, a series of numerical simulations are performed using finite element analysis to evaluate the global damage of concrete overpack as well as its local damage under high speed missile impact. We consider two types of concrete overpack, one with steel in-cased concrete without reinforcement and the other with partially-confined reinforced concrete. The numerical simulation results are compared with test results and it is shown that appropriate modeling of material failure is crucial in this analysis and the results are highly dependent on the choice of failure parameters. (authors)

  11. Pulse oximeter improvement with an ADC-DAC feedback loop and a radial reflectance sensor.

    Science.gov (United States)

    Thompson, David; Wareing, Austin; Day, Dwight; Warren, Steve

    2006-01-01

    Pulse oximeter circuitry must meet several design constraints, including the ability to separate a small pulsatile signal component from a large signal baseline. This paper describes pulse oximeter design changes that produced order-of-magnitude improvements in signal quality. The primary changes were (a) the replacement of an analog sample-and-hold-based differentiator circuit with an ADC-DAC feedback loop and (b) the replacement of a side-by-side reflectance sensor design with a radial sensor arrangement that maximizes the pulsatile-to-baseline signal ratio.

  12. Dynamic Test of a Collision Post of a State-of-the-Art End Frame Design

    Science.gov (United States)

    2008-09-24

    In support of the Federal Railroad Administration's (FRA) : Railroad Equipment Safety Program, a full-scale dynamic test : of a collision post of a state-of-the-art (SOA) end frame was : conducted on April 16, 2008. The purpose of the test was to : e...

  13. Automated Testing Techniques for Event-Driven and Dynamically Typed Software Applications

    DEFF Research Database (Denmark)

    Adamsen, Christoffer Quist

    2018-01-01

    Software testing is the process of executing a software application on a set of inputs, and determining if the application behaves as intended on these inputs. This thesis focuses on testing techniques for event-driven and dynamically typed applications. This is an important class of software, wh...

  14. Evolution of Ada technology in the flight dynamics area: Implementation/testing phase analysis

    Science.gov (United States)

    Quimby, Kelvin L.; Esker, Linda; Miller, John; Smith, Laurie; Stark, Mike; Mcgarry, Frank

    1989-01-01

    An analysis is presented of the software engineering issues related to the use of Ada for the implementation and system testing phases of four Ada projects developed in the flight dynamics area. These projects reflect an evolving understanding of more effective use of Ada features. In addition, the testing methodology used on these projects has changed substantially from that used on previous FORTRAN projects.

  15. Two improved methods for testing ADC parametric faults by digital input signals

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2009-01-01

    In this paper, two improved methods are presented extending our previous work. The first one improves the results by adjusting the voltage levels of the input pulse wave stimulus. Compared with the sine wave input stimulus, the four-level pulse wave can detect even more faulty cases with the offset

  16. Dynamic Characteristics of a New Machine for Fatigue Testing of Railway Axles – Part 2

    Directory of Open Access Journals (Sweden)

    Karel FRYDRÝŠEK

    2012-06-01

    Full Text Available There were done some proposal calculations for a new testing machine. This new testing machine is determined for a dynamic fatigue testing of railway axles. The railway axles are subjected to bending and rotation (centrifugal effects. For the right proposition of a new machine is very important to know the basic dynamic characteristics of whole system. These dynamic characteristics are solved via FEM (MSC.Marc/Mentat software in combination with SBRA (Simulation-Based Reliability Assessment Method (probabilistic Monte Carlo approach, Anthill and Python software. The proposed dimensions and springs of a new machine for fatigue testing of railway axles were used for manufacturing. Application of the SBRA method connected with FEM in these areas is a new and innovative trend in mechanics. This paper is continuation of former work (i.e. easier deterministic approach already presented in this journal in 2007.

  17. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...... and the natural experimental method. The identified collector parameters are then compared and analyzed with those obtained by the steady state test method and the QDT test method. The results comparison shows that the L-QDT method and the natural experimental method are also valid. It can be concluded...

  18. In Situ Test Study of Characteristics of Coal Mining Dynamic Load

    Directory of Open Access Journals (Sweden)

    Jiang He

    2015-01-01

    Full Text Available Combination of coal mining dynamic load and high static stress can easily induce such dynamic disasters as rock burst, coal and gas outburst, roof fall, and water inrush. In order to obtain the characteristic parameters of mining dynamic load and dynamic mechanism of coal and rock, the stress wave theory is applied to derive the relation of mining dynamic load strain rate and stress wave parameters. The in situ test was applied to study the stress wave propagation law of coal mine dynamic load by using the SOS microseismic monitoring system. An evaluation method for mining dynamic load strain rate was proposed, and the statistical evaluation was carried out for the range of strain rate. The research results show that the loading strain rate of mining dynamic load is in direct proportion to the seismic frequency of coal-rock mass and particle peak vibration velocity and is in inverse proportion to wave velocity. The high-frequency component damps faster than the low-frequency component in the shockwave propagating process; and the peak particle vibration velocity has a power functional relationship with the transmitting distance. The loading strain rate of mining dynamic load is generally less than class 10−1/s.

  19. Recombinant Chimpanzee Adenovirus Vaccine AdC7-M/E Protects against Zika Virus Infection and Testis Damage.

    Science.gov (United States)

    Xu, Kun; Song, Yufeng; Dai, Lianpan; Zhang, Yongli; Lu, Xuancheng; Xie, Yijia; Zhang, Hangjie; Cheng, Tao; Wang, Qihui; Huang, Qingrui; Bi, Yuhai; Liu, William J; Liu, Wenjun; Li, Xiangdong; Qin, Chuan; Shi, Yi; Yan, Jinghua; Zhou, Dongming; Gao, George F

    2018-03-15

    The recent outbreak of Zika virus (ZIKV) has emerged as a global health concern. ZIKV can persist in human semen and be transmitted by sexual contact, as well as by mosquitoes, as seen for classical arboviruses. We along with others have previously demonstrated that ZIKV infection leads to testis damage and infertility in mouse models. So far, no prophylactics or therapeutics are available; therefore, vaccine development is urgently demanded. Recombinant chimpanzee adenovirus has been explored as the preferred vaccine vector for many pathogens due to the low preexisting immunity against the vector among the human population. Here, we developed a ZIKV vaccine based on recombinant chimpanzee adenovirus type 7 (AdC7) expressing ZIKV M/E glycoproteins. A single vaccination of AdC7-M/E was sufficient to elicit potent neutralizing antibodies and protective immunity against ZIKV in both immunocompetent and immunodeficient mice. Moreover, vaccinated mice rapidly developed neutralizing antibody with high titers within 1 week postvaccination, and the elicited antiserum could cross-neutralize heterologous ZIKV strains. Additionally, ZIKV M- and E-specific T cell responses were robustly induced by AdC7-M/E. Moreover, one-dose inoculation of AdC7-M/E conferred mouse sterilizing immunity to eliminate viremia and viral burden in tissues against ZIKV challenge. Further investigations showed that vaccination with AdC7-M/E completely protected against ZIKV-induced testicular damage. These data demonstrate that AdC7-M/E is highly effective and represents a promising vaccine candidate for ZIKV control. IMPORTANCE Zika virus (ZIKV) is a pathogenic flavivirus that causes severe clinical consequences, including congenital malformations in fetuses and Guillain-Barré syndrome in adults. Vaccine development is a high priority for ZIKV control. In this study, to avoid preexisting anti-vector immunity in humans, a rare serotype chimpanzee adenovirus (AdC7) expressing the ZIKV M

  20. Testing Object-Oriented Programs using Dynamic Aspects and Non-Determinism

    DEFF Research Database (Denmark)

    Achenbach, Michael; Ostermann, Klaus

    2010-01-01

    without parameterization or generation of tests. It also eases modelling naturally non-deterministic program features like IO or multi-threading in integration tests. Dynamic AOP facilitates powerful design adaptations without exposing test features, keeping the scope of these adaptations local to each......The implementation of unit tests with mock objects and stubs often involves substantial manual work. Stubbed methods return simple default values, therefore variations of these values require separate test cases. The integration of mock objects often requires more infrastructure code and design...... decisions exposing private data. We present an approach that both improves the expressiveness of test cases using non-deterministic choice and reduces design modifications using dynamic aspect-oriented programming techniques. Non-deterministic choice facilitates local definitions of multiple executions...

  1. [The relevance of ADC value, T₁intensive rate and the clinical activities in ankylosing spondylitis sacroiliitis].

    Science.gov (United States)

    Zhao, Yinghua; Han, Xinai; Hu, Shaoyong; Shi, Xingliang; Zhao, Jing; Sun, Erwei; Li, Shaolin

    2014-09-23

    To evaluate the value of judging for the activity in AS by diffusion-weighted sequences (DWI) and enhance sequences MRI(DCE-MRI), to explore the correlation of Apparent diffusion coefficient(ADC) values, intensive rate and the clinical activity index in sacroiliitis (SIJ) of ankylosing spondylitis (AS). 56 patients prospectively choiced and diagnosed were divided into two groupsas, active group (n = 32) and chronic group (n = 24) by rheumatologist according to BASDAI and laboratory parameters. Twenty healthy adults were as control group. The values of ADC and intensive rate of all sacroiliac joints (SIJs) were measured on MRI. BASDAI score were got by Bath ankylosing spondylitis disease activity index. ESR, CPR and were got by laboratory. Statisticaly to analysis whether the parameters were significantly different amang AS active, chronic, and the control group. To assess the correlation of the values of ADC, intensive rate and BASDAI score, ESR, CPR and in SIJ. the values of ADC and intensive rate were significantly different among AS active, chronic and the control group. There were the significant correlation between the values of ADC, intensive rate and BASDAI score. Diffusion-weighted sequences and Contrast-enhanced sequences is superior to other methods in judging the activity in AS.combined with clinical activity index, the accuracy can significantly be improved to explore whether the activities of AS are.

  2. A 1.9 μW 4.4 fJ/conversion-step, 10 bit, 1 MS/s charge redistribution ADC

    NARCIS (Netherlands)

    van Elzakker, Michel; van Tuijl, Adrianus Johannes Maria; Geraedts, P.F.J.; Schinkel, Daniel; Klumperink, Eric A.M.; Nauta, Bram

    2008-01-01

    A 10b SAR ADC uses a charge redistribution DAC, a two-stage comparator, and a delay-line-based controller. The ADC does not use any static bias current and power consumption is proportional to sample rate. At 1MS/s, the ADC uses 1.9μW. With 8.75 ENOB, the resulting FOM is 4.4fJ/conversion-step.

  3. X-ray testing for short-time dynamic applications; Roentgenuntersuchungen fuer kurzzeitdynamische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried [Fraunhofer-Institut fuer Kurzzeitdynamik, Efringen-Kirchen (Germany). Ernst-Mach-Inst. (EMI)

    2017-08-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  4. Predicting Software Test Effort in Iterative Development Using a Dynamic Bayesian Network

    OpenAIRE

    Torkar, Richard; Awan, Nasir Majeed; Alvi, Adnan Khadem; Afzal, Wasif

    2010-01-01

    Projects following iterative software development methodologies must still be managed in a way as to maximize quality and minimize costs. However, there are indications that predicting test effort in iterative development is challenging and currently there seem to be no models for test effort prediction. This paper introduces and validates a dynamic Bayesian network for predicting test effort in iterative software devel- opment. The proposed model is validated by the use of data from two indu...

  5. Dynamic testing of large AISI-316L steel specimens behaviour using LDTF

    International Nuclear Information System (INIS)

    Casadei, F.; Delzano, C.; Magonette, G.; Halleux, J.P.; Verzeletti, G.

    1987-01-01

    The paper presents the results of a series of dynamic experiments on AISI-316L steel specimens having a cross section of 2000 mm 2 and a gauge length of 350 mm subject to dynamic traction up to rupture. Results for dynamic tests at a nominal strain rate up to 50 s -1 are compared to quasi-static ones, showing an important increase in both yield stress and flow stress. The experimental techniques are described, with special emphasis on full-field optical strain measurements based on Moire interferometry. A 1-D numerical analysis of the experiments is presented. (orig.)

  6. Dynamics testing of large AISI 316L steel specimens behaviour using L.D.T.F

    International Nuclear Information System (INIS)

    Casadei, F.; Delzano, C.; Magonette, G.; Halleux, J.P.; Verzeletti, G.

    1986-01-01

    The paper presents the results of a series of dynamic experiments on AISI-316L steel specimens having a cross section of 2000 mm 2 and a gauge length of 350 mm subject to dynamic traction up to rupture. Results for dynamic tests at a nominal strain rate up to 50 s -1 are compared to quasi-static ones, showing an important increase in both yield stress and flow stress. The experimental techniques are described, with special emphasis on full-field optical strain measurements based on Moire interferometry. A 1-D numerical analysis of the experiments is presented. (orig.)

  7. Evaluation of dynamic fracture toughness for Yong Gwang unit 5 reactor pressure vessel materials (Baseline Tests)

    Energy Technology Data Exchange (ETDEWEB)

    Chi Se Hwan; Kim, Joo Hag; Hong, Jun Hwa; Kwon, Sun Chil; Lee, Bong Sang [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    The dynamic fracture toughness (K{sub d}) of intermediate shell and its weld in SA 508 CI. 3 Yong Gwang 5 reactor pressure vessel was determined and evaluated. Precracked thirty six Charpy specimens were tested by using an instrumented impact tester. The purpose of present work is to evaluate and confirm the un-irradiated dynamic fracture toughness and to provide pre-irradiation baseline data for future evaluation on dynamic fracture toughness change during operation. 18 refs., 5 figs., 5 tabs. (Author)

  8. High Performance Analysis of CDS Delta-Sigma ADC in 45-Nanometer Regime

    Science.gov (United States)

    Bhargava, Bhanupriya; Sharma, Pradeep Kumar; Akashe, Shyam

    2014-03-01

    In this paper, a correlated double sampling (CDS) technique is proposed in the design of a delta sigma analog-to-digital converter (ADC). These CDS techniques are very effective for the compensation of the nonidealities in switched-capacitor (SC) circuits, such as charge injection, clock feed-through, operational amplifier (op-amp) input-referred offset and finite op-amp gain. An improved compensation scheme is proposed to attain continuous compensation of clock feed-through and offset in SC integrators. Both high-speed and low-power operation is achieved without compromising the accuracy requirement. Also this CDS delta sigma ADC is the most promising circuit for analog to digital converter because this circuit reduces noise due to drift and low frequency noise such as flicker noise and offset voltage and also boosts the gain performance of the amplifier. Further, the simulation results of this circuit are verified on using a "cadence virtuoso tool" using spectre at 45 nm technology with supply voltage 0.7 V.

  9. A power scalable PLL frequency synthesizer for high-speed Δ—Σ ADC

    International Nuclear Information System (INIS)

    Han Siyang; Chi Baoyong; Zhang Xinwang; Wang Zhihua

    2014-01-01

    A 35–130 MHz/300–360 MHz phase-locked loop frequency synthesizer for Δ—Σ analog-to-digital converter (ADC) in 65 nm CMOS is presented. The frequency synthesizer can work in low phase-noise mode (300–360 MHz) or in low-power mode (35–130 MHz) to satisfy the ADC's requirements. To switch between these two modes, a high frequency GHz LC VCO followed by a divided-by-four frequency divider and a low frequency ring VCO followed by a divided-by-two frequency divider are integrated on-chip. The measured results show that the frequency synthesizer achieves a phase-noise of −132 dBc/Hz at 1 MHz offset and an integrated RMS jitter of 1.12 ps with 1.74 mW power consumption from a 1.2 V power supply in low phase-noise mode. In low-power mode, the frequency synthesizer achieves a phase-noise of −112 dBc/Hz at 1 MHz offset and an integrated RMS jitter of 7.23 ps with 0.92 mW power consumption from a 1.2 V power supply. (semiconductor integrated circuits)

  10. Functional decline in the elderly with MCI: Cultural adaptation of the ADCS-ADL scale

    Directory of Open Access Journals (Sweden)

    Fabiana Carla Matos da Cunha Cintra

    Full Text Available Summary Objective: Translate, transcultural adaptation and application to Brazilian Portuguese of the Alzheimer’s Disease Cooperative Study - Activities of Daily Living (ADCS-ADL scale as a cognitive screening instrument. Method: We applied the back translation added with pretest and bilingual methods. The sample was composed by 95 elderly individuals and their caregivers. Thirty-two (32 participants were diagnosed as mild cognitive impairment (MCI patients, 33 as Alzheimer’s disease (AD patients and 30 were considered as cognitively normal individuals. Results: There were only little changes on the scale. The Cronbach alpha coefficient was 0.89. The scores were 72.9 for control group, followed by MCI (65.1 and by AD (55.9, with a p-value < 0.001. The ROC curve value was 0.89. We considered a cut point of 72 and we observed a sensibility of 86.2%, specificity of 70%, positive predictive value of 86.2%, negative predictive value of 70%, positive likelihood ratio of 2.9 and negative likelihood ratio of 0.2. Conclusion: ADCS-ADL scale presents satisfactory psychometric properties to discriminate between MCI, AD and normal cognition.

  11. Atypical manifestations of reversible posterior leukoencephalopathy syndrome: findings on diffusion imaging and ADC mapping

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.J.; You, W.J.; Jeong, S.L.; Lee, J.W.; Kim, B.S.; Lee, J.H.; Hahn, S.T. [Dept. of Radiology, The Catholic Univ. of Korea, St. Mary' s Hospital, Seoul (Korea); Yang, D.W.; Son, Y.M. [Dept. of Neurology, The Catholic Univ. of Korea, St. Mary' s Hospital, Seoul (Korea)

    2004-12-01

    Typically, reversible posterior leukoencephalopathy syndrome (RPLS) involves the parieto-occipital lobes. When regions of the brain other than the parieto-occipital lobes are predominantly involved, the syndrome can be called atypical RPLS. The purpose of this study is to find radiological and pathophysiological features of atypical RPLS by using diffusion-weighted imaging (D-WI). We retrospectively reviewed seven patients (two with eclampsia, one with cyclosporine neurotoxicity, and four with hypertensive encephalopathy) with atypical MR manifestations of RPLS. Changes in signal intensity on T2-weighted imaging (T2-WI) and D-WI, and ADC ratio, were analyzed. In patients with atypical manifestation of RPLS, high signal intensities on T2-WI were noted in the frontal lobe, basal ganglia, thalamus, brainstem, and subcortical white matter in regions other than the parieto-occipital lobes. These areas of increased signal intensities on T2-WI showed increased ADC values, representing vasogenic edema in all seven patients. This result should be very useful in differentiating atypical RPLS from other metabolic brain disorders that affect the same sites with cytotoxic edema. (orig.)

  12. A 12-bit SAR ADC integrated on a multichannel silicon drift detector readout IC

    Science.gov (United States)

    Schembari, F.; Bellotti, G.; Fiorini, C.

    2016-07-01

    A 12-bit analog-to-digital converter (ADC) addressed to Silicon-Drift Detectors (SDDs) multichannel readout ASICs for X- and gamma-ray applications is presented. Aiming at digitizing output multiplexed data from the upstream analog filters banks, the converter must ensure 11-bit accuracy and a sampling frequency of about 5 MS/s. The ADC architecture is the charge-redistribution (CR) successive-approximation register (SAR). A fully differential topology has also been chosen for better rejection of common-mode noise and disturbances. The internal DAC is made of binary-scaled capacitors, whose bottom plates are switched by the SAR logic to perform the binary search of the analog input value by means of the monotonic switching scheme. The A/D converter is integrated on SFERA, a multichannel ASIC fabricated in a standard CMOS 0.35 μm 3.3 V technology and it occupies an area of 0.42 mm2. Simulated static performance shows monotonicity over the whole input-output characteristic. The description of the circuit topology and of inner blocks architectures together with the experimental characterization is here presented.

  13. Realizing Low-Energy Classification Systems by Implementing Matrix Multiplication Directly Within an ADC.

    Science.gov (United States)

    Wang, Zhuo; Zhang, Jintao; Verma, Naveen

    2015-12-01

    In wearable and implantable medical-sensor applications, low-energy classification systems are of importance for deriving high-quality inferences locally within the device. Given that sensor instrumentation is typically followed by A-D conversion, this paper presents a system implementation wherein the majority of the computations required for classification are implemented within the ADC. To achieve this, first an algorithmic formulation is presented that combines linear feature extraction and classification into a single matrix transformation. Second, a matrix-multiplying ADC (MMADC) is presented that enables multiplication between an analog input sample and a digital multiplier, with negligible additional energy beyond that required for A-D conversion. Two systems mapped to the MMADC are demonstrated: (1) an ECG-based cardiac arrhythmia detector; and (2) an image-pixel-based facial gender detector. The RMS error over all multiplication performed, normalized to the RMS of ideal multiplication results is 0.018. Further, compared to idealized versions of conventional systems, the energy savings obtained are estimated to be 13× and 29×, respectively, while achieving similar level of performance.

  14. High-speed ADC and DAC modules with fibre optic interconnections for telecom satellites

    Science.gov (United States)

    Heikkinen, Veli; Juntunen, Eveliina; Karppinen, Mikko; Kautio, Kari; Ollila, Jyrki; Sitomaniemi, Aila; Tanskanen, Antti; Casey, Rory; Scott, Shane; Gachon, Hélène; Sotom, Michel; Venet, Norbert; Toivonen, Jaakko; Tuominen, Taisto; Karafolas, Nikos

    2017-11-01

    The flexibility required for future telecom payloads calls for the introduction of more and more digital processing capabilities. Aggregate data throughputs of several Tbps will have to be handled onboard, thus creating the need for effective, ADCDSP and DACDSP highspeed links. ADC and DAC modules with optical interconnections is an attractive option as it can solve easily the transmission and routing of the expected huge amount of data. This technique will enable to increase the bandwidth and/or the number of beams/channels to be treated, or to support advanced digital processing architectures including beam forming. We realised electrooptic ADC and DAC modules containing an 8 bit, 2 GSa/s A/D converter and a 12 bit, 2 GSa/s D/A converter. The 4channel parallel fibre optic link employs 850nm VCSELs and GaAs PIN photodiodes coupled to 50/125μm fibre ribbon cable. ADCDSP and DSPDAC links both have an aggregate data rate of 25 Gbps. The paper presents the current status of this development.

  15. Experimental test of static and dynamic characteristics of tilting-pad thrust bearings

    Directory of Open Access Journals (Sweden)

    Annan Guo

    2015-07-01

    Full Text Available The axial vibration in turbine machine has attracted more and more interest. Tilting-pad thrust bearings are widely used in turbine machines to support the axial load. The dynamic properties generated by oil film of the thrust pad have important effects on the axial vibration of the rotor-bearing system. It is necessary to develop the method to test the dynamic characteristics of thrust bearings. A new rig has been developed. The facility allows a complete set of bearing operating parameters to be measured. Parameters measured include oil temperatures, oil-film thickness, and pressure. The static load and dynamic load can be added on the thrust bearing in the vertical direction at the same time. The relative and absolute displacement vibrations of the test experimental bearing with the changes of dynamic force are measured, and the dynamic characteristics of the test bearing are obtained. The experimental results show clearly that the operating conditions influence largely on the pad static and dynamic characteristics.

  16. Creating a Test Validated Structural Dynamic Finite Element Model of the Multi-Utility Technology Test Bed Aircraft

    Science.gov (United States)

    Pak, Chan-Gi; Truong, Samson S.

    2014-01-01

    Small modeling errors in the finite element model will eventually induce errors in the structural flexibility and mass, thus propagating into unpredictable errors in the unsteady aerodynamics and the control law design. One of the primary objectives of Multi Utility Technology Test Bed, X-56A, aircraft is the flight demonstration of active flutter suppression, and therefore in this study, the identification of the primary and secondary modes for the structural model tuning based on the flutter analysis of X-56A. The ground vibration test validated structural dynamic finite element model of the X-56A is created in this study. The structural dynamic finite element model of the X-56A is improved using a model tuning tool. In this study, two different weight configurations of the X-56A have been improved in a single optimization run.

  17. Non-linear beam dynamics tests in the LHC: measurement of intensity decay for probing dynamic aperture at injection

    CERN Document Server

    Cettour Cave, S; Giovannozzi, M; Ludwig, M; MacPherson, A; Redaelli, S; Roncarolo, F; Solfaroli Camillocci, M; Venturini Delsolaro, W

    2013-01-01

    For a second year in a row dynamic aperture experiments have been performed at the LHC. These studies have been carried out by two teams following alternative techniques: On Beam 1 a novel approach has been tested which heats the beam until the emittance becomes large, and derives the dynamic aperture from beam losses assuming an inverse logarithm model for the time-dependence of the intensity. On Beam 2, the traditional approach of sampling the dynamic aperture with large amplitude kicks has been pursued [1]. In 2011, considerable progress was made and impressive results have been reported. In 2012 a further Machine Development (MD) session was scheduled during which both teams have benefited from an improved availability of the beams and more optimal performance of the instrumentation. Observations and analysis are presented as two MD reports of the LHC dynamic aperture experiment MD. This note describes the observations made on Beam 1, when the strength of the spool pieces have been varied. The key quantit...

  18. Models of the heat dynamics of solar collectors for performance testing

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    The need for fast and accurate performance testing of solar collectors is increasing. This paper describes a new technique for performance testing which is based on non-linear continuous time models of the heat dynamics of the collector. It is shown that all important performance parameters can...... be accurately estimated with measurements from a single day. The estimated parameters are compared with results from standardized test methods (Fischer et al., 2004). Modelling the dynamics of the collector is carried out using stochastic differential equations, which is a well proven efficient method to obtain...... accurate estimates of parameters in physical models. The applied method is described by Kristensen et al. (2004) and implemented in the software CTSM1. Examples of successful applications of the method includes modelling the of the heat dynamics of integrated photo-voltaic modules (Friling et al., 2009...

  19. STATIC AND DYNAMIC IN VITRO TEST OF BIOACTIVITY OF GLASS CERAMICS

    Directory of Open Access Journals (Sweden)

    JANA KOZÁNKOVÁ

    2011-06-01

    Full Text Available The bioactivity of glass ceramics from Li2O–SiO2–CaO–P2O5–CaF2 system, with different amount of fluorapatite expressed as P2O5 content, has been tested in vitro under static and dynamic regime. The paper reports the results of bioactivity test of glass ceramics in static and dynamic regime. XRD, SEM and EPMA analysis were used to characterise the sample as well as to detect the presence of new phase onto the surface of glass ceramics. The bioactivity, as demonstrated by the formation of new apatite layer, depends on P2O5 content and testing regime. In static regime, one can observe a fine microstructure of hydroxyapatite layer on the surface on glass ceramics samples. In dynamic regime, the formation rate of this layer seems to be retarded in comparison with that of static regime.

  20. Design, analysis, and testing of a hybrid scale structural dynamic model of a Space Station

    Science.gov (United States)

    Gronet, Marc J.; Crawley, Edward F.; Allen, Bradley R.

    1989-01-01

    The impracticality of testing the fully-assembled on-orbit configurations of future large erectable space platforms fosters an increased reliance on other means for verifying predicted structural dynamic performance. One option is scale modeling. This paper discusses the design of a hybrid scale dynamic test model of the Freedom Space Station and its associated suspension system. Hybrid scaling laws are reviewed, followed by scale factor trades, component design examples, and an analytical evaluation of the overall model fidelity. Component and subassembly test results from a six-bay hybrid scale model truss are presented. Potential interactions of gravity and the suspension system with the free-free dynamics of the scale model are investigated. Suspension system design parameters, such as the number, location, mass, and stiffness of the suspension devices are traded to minimize undesirable interactions and form the basis for an overall suspension system concept for the scale model.

  1. The role of the modified taylor impact test in dynamic material research

    Directory of Open Access Journals (Sweden)

    Bagusat Frank

    2015-01-01

    Full Text Available Dynamic material research with strain rates of more than 1000 1/s is experimentally very often done with a Split-Hopkinson Bar, Taylor impact tests or planar plate impact test investigations. At the Ernst-Mach-Institut (EMI, a variant of an inverted classical Taylor impact test is used by application of velocity interferometers of the VISAR type (“Modified Taylor Impact Test”, MTT. The conduction of the experiments is similar to that of planar plate impact tests. The data reduction and derivation of dynamic material data can also be restricted to an analysis of the VISAR signal. Due to these properties, nearly each highly dynamic material characterization in our institute done by planar plate investigations is usually accompanied by MTT experiments. The extended possibilities and usefulness of a combined usage of these two highly dynamic characterization methods are explained. Recently, further developed MTT experiments with very small specimen sizes are presented. For the first time, Taylor impact and planar impact specimen can be used for which the load directions even in case of thin plate test material are identical and not perpendicular to each other. Consequences for testing construction elements are discussed.

  2. Resistance factors for 100% dynamic testing, with and without static load tests.

    Science.gov (United States)

    2011-05-01

    Current department of transportation (DOT) and Federal Highway Administration (FHWA) practice has highly : variable load and resistance factor design (LRFD) resistance factors, , for driven piles from design (e.g., Standard : Penetration Tests (SPT...

  3. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahrsow, Maximilian, E-mail: mlahrsow@gmail.com; Albrecht, Moritz H. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany); Bickford, Matthew W. [Medical University of South Carolina, Department of Radiology and Radiological Science (United States); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10{sup −3} mm{sup 2}/s) and no response (median 1.30 × 10{sup −3} mm{sup 2}/s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  4. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

    International Nuclear Information System (INIS)

    Lahrsow, Maximilian; Albrecht, Moritz H.; Bickford, Matthew W.; Vogl, Thomas J.

    2017-01-01

    PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10 −3  mm 2 /s) and no response (median 1.30 × 10 −3  mm 2 /s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  5. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy.

    Science.gov (United States)

    Lahrsow, Maximilian; Albrecht, Moritz H; Bickford, Matthew W; Vogl, Thomas J

    2017-06-01

    To use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment. Fifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions. One month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10 -3  mm 2 /s) and no response (median 1.30 × 10 -3  mm 2 /s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC. In patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  6. Analysis and test for space shuttle propellant dynamics (1/10th scale model test results). Volume 1: Technical discussion

    Science.gov (United States)

    Berry, R. L.; Tegart, J. R.; Demchak, L. J.

    1979-01-01

    Space shuttle propellant dynamics during ET/Orbiter separation in the RTLS (return to launch site) mission abort sequence were investigated in a test program conducted in the NASA KC-135 "Zero G" aircraft using a 1/10th-scale model of the ET LOX Tank. Low-g parabolas were flown from which thirty tests were selected for evaluation. Data on the nature of low-g propellant reorientation in the ET LOX tank, and measurements of the forces exerted on the tank by the moving propellent will provide a basis for correlation with an analytical model of the slosh phenomenon.

  7. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  8. Progression of emphysema in a 12-month hyperpolarized 3He-MRI study: lacunarity analysis provided a more sensitive measure than standard ADC analysis

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2009-01-01

    RATIONALE AND OBJECTIVES: Inhaled hyperpolarized (3)He magnetic resonance (MR) imaging has been used to measure alveolar size in patients with emphysema. The aim of this study was to test the hypothesis that (3)He MR images could be used to develop a biomarker of emphysema progression. MATERIALS...... AND METHODS: Twelve healthy controls and 18 patients with emphysema (eight current smokers, 10 ex-smokers) were imaged at baseline and 6 and 12 months. An additional nine subjects with alpha-1 antitrypsin deficiency (four with emphysema, six without symptoms) were also imaged at baseline and at 6 months. Each...... subject was imaged at two lung volumes: functional residual capacity (FRC) and FRC plus 15% of total lung capacity. Means and standard deviations of apparent diffusion coefficients (ADCs) were calculated from coronal images of the entire lung and correlated with pulmonary function test results...

  9. Design, fabrication, and dynamic testing of a V-groove radiator mechanical development unit

    Science.gov (United States)

    Petrick, S. Walter; Bard, Steven

    1988-01-01

    This paper describes the design, fabrication, and dynamic testing of a V-groove radiator development unit. The intended goal was to survive the dynamic environment of the Mars Observer mission. The development unit was designed to achieve a temperature of 80 K with a heat load of about 80 milliwatts. An analysis was performed to predict the thermal performance of the development unit. The radiator with a mass mockup of a Gamma Ray Spectrometer detector, the most massive of the candidate Mars Observer instrument detectors (1.7 Kg), passed vibration and acoustic testing to the Mars Observer requirements in effect at that time.

  10. Monitoring T2 and ADC at 9.4 T following fractionated external beam radiation therapy in a mouse model

    International Nuclear Information System (INIS)

    Larocque, Matthew P; Syme, Alasdair; Yahya, Atiyah; Wachowicz, Keith; Fallone, B Gino; Allalunis-Turner, Joan

    2010-01-01

    The purpose of this study is to investigate the response of transverse relaxation time (T2) and apparent diffusion coefficient (ADC) in human glioma tumor xenografts during and after fractionated radiotherapy. Tumor-bearing mice were divided into four treatment groups (n = 6 per group) that received a total dose of 800 cGy of 200 kVp x-rays, given over two or three fractions, with a fraction spacing of either 24 or 72 h. A fifth treatment group received 800 cGy in a single fraction, and a sixth group of mice served as an untreated control. All mice were scanned pretreatment, before each fraction and at multiple points after treatment using a 9.4 T magnetic resonance imaging (MRI) system. Quantitative T2 and ADC maps were produced. All treated groups showed an increase in mean tumor ADC, though the time for this response to reach a maximum and return toward baseline was delayed in the fractionated groups. The highest ADC was measured 7 days after the final fraction of treatment for all groups. There were no significant differences in the maximum measured change in ADC between any of the treated groups, with the average measured maximum value being 20.5% above baseline. After treatment, all groups showed an increase in mean tumor T2, with the average measured maximum T2 being 4.7% above baseline. This increase was followed by a transition to mean T2 values below baseline values, with the average measured tumor T2 being 92.4% of the pretreatment value. The transition between elevated and depressed T2 values was delayed in the cases of fractionated therapies and occurred between 3.6 and 7.3 days after the last fraction of treatment. These results further the understanding of the temporal evolution of T2 and ADC during fractionated radiotherapy and support their potential use as time-sensitive biomarkers for tumor response.

  11. Monitoring T2 and ADC at 9.4 T following fractionated external beam radiation therapy in a mouse model

    Science.gov (United States)

    Larocque, Matthew P.; Syme, Alasdair; Yahya, Atiyah; Wachowicz, Keith; Allalunis-Turner, Joan; Fallone, B. Gino

    2010-03-01

    The purpose of this study is to investigate the response of transverse relaxation time (T2) and apparent diffusion coefficient (ADC) in human glioma tumor xenografts during and after fractionated radiotherapy. Tumor-bearing mice were divided into four treatment groups (n = 6 per group) that received a total dose of 800 cGy of 200 kVp x-rays, given over two or three fractions, with a fraction spacing of either 24 or 72 h. A fifth treatment group received 800 cGy in a single fraction, and a sixth group of mice served as an untreated control. All mice were scanned pretreatment, before each fraction and at multiple points after treatment using a 9.4 T magnetic resonance imaging (MRI) system. Quantitative T2 and ADC maps were produced. All treated groups showed an increase in mean tumor ADC, though the time for this response to reach a maximum and return toward baseline was delayed in the fractionated groups. The highest ADC was measured 7 days after the final fraction of treatment for all groups. There were no significant differences in the maximum measured change in ADC between any of the treated groups, with the average measured maximum value being 20.5% above baseline. After treatment, all groups showed an increase in mean tumor T2, with the average measured maximum T2 being 4.7% above baseline. This increase was followed by a transition to mean T2 values below baseline values, with the average measured tumor T2 being 92.4% of the pretreatment value. The transition between elevated and depressed T2 values was delayed in the cases of fractionated therapies and occurred between 3.6 and 7.3 days after the last fraction of treatment. These results further the understanding of the temporal evolution of T2 and ADC during fractionated radiotherapy and support their potential use as time-sensitive biomarkers for tumor response.

  12. Study of the influence of ADC sampling rate on the efficiency of neutron-gamma discrimination by the pulse shape

    Science.gov (United States)

    Chepurnov, A. S.; Gavrilenko, O. I.; Kirsanov, M. A.; Klimanov, S. G.; Kubankin, A. S.

    2017-12-01

    The influence of a sampling rate of ADC on the efficiency of the pulse shape discrimination procedure (PSDP) developed for gamma-neutron discrimination was studied. Pu-Be neutron source and two types of digitizers (CAEN DT5730 and CAEN DT5743) were used. Both digitizers together with application software allow to store sequences of waveforms from a scintillation detector. The functional features of the CAEN DT5730 and CAEN DT5743 are described, and experimental characteristics of their operation are compared. Experimental values of an efficiency of neutron/gamma signal discrimination using two ADCs with different sampling frequencies are presented.

  13. Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing system

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E 4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the c...

  14. Development of diagnostic test instruments to reveal level student conception in kinematic and dynamics

    Science.gov (United States)

    Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.

    2018-03-01

    The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.

  15. Testing and evaluation of wheelchair caster assemblies subjected to dynamic crash loading.

    Science.gov (United States)

    Bertocci, G E; Esteireiro, J; Cooper, R A; Young, T M; Thomas, C

    1999-01-01

    Wheelchair designs based upon loads applied quasi-statically during normal mobility use are apt to be inadequate to handle the increased level of dynamic crash forces that may be encountered when using the wheelchair as a motor vehicle seat. The purpose of this study was to characterize the integrity of wheelchair caster assemblies under simulated crash conditions. This study utilized dynamic drop (DD) testing, with loading levels and rates adjusted to match those found previously in sled impact testing and computer crash simulations. The results verify that current caster assembly designs may not be able to withstand forces associated with a crash. Five of seven evaluated caster assemblies failed when loaded to 8,007 N, or less, at loading rates seen in sled testing. DD testing used in this study is a valuable tool that can be used in the design of transport wheelchair components.

  16. Conspray dynamic sleeve piston coal feeder. Phase II. Verification tests. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-26

    This report details the performance of Phase II: Verification Tests of the Conspray dynamic sleeve piston coal feeder. The machine performed for 200 hours at 700 psi backpressure, utilizing a 70% to 200 mesh Utah bituminous coal as feedstock. All test work was satisfactorily completed. A post-test inspection was performed. A report of component wear and failures incurred in testing is included as well as suggestions for machine upgrades. The overall conclusion is that the dynamic sleeve piston feeder has proven its ability to operate safely and reliably. When problems have occurred, the machine has demonstrated inherent safety by shutting down without endangering process or personnel. With the recommended improvements incorporated into the feeder, the unit will be ready for installation on a pilot scale coal gasifier. 9 figures, 11 tables.

  17. Dynamic test of the ITER blanket key and ceramic insulated pad

    International Nuclear Information System (INIS)

    Khomyakov, S.; Sysoev, G.; Strebkov, Yu.; Kucherov, A.; Ioki, K.

    2010-01-01

    The dynamic testing of the blanket module's key integrated into ITER vacuum vessel portion has been performed in 2008 to investigate its capability to react the electro-magnetic (EM) loads. The preliminary analysis showed the large dynamic amplification factor (DAF) of the reactions because of technological gaps between the blanket module and key. Shock load may yield the bronze pads, which protect the blanket electrical insulation from damage. However the dynamic analysis of such particularly non-linear system needs an experimental ground and confirmation. Toward this end, as well as demonstration of the key reliability, the special test facility has been made, and the full-scale mock-up of the inboard intermodular key was tested. So as not to scale non-linear dynamic parameters, 1-ton mass was built on the single flexible support. The key was welded in a 60-mm thick steel plate modeled with a fragment of the VV. The different gaps were set in between the bronze pad of the key and the mass shock worker. This system (supplemented with some additional constraints) has natural oscillations like as the 4-ton module built on four flexible supports. Thus the most critical radial torque might be modeled with a straight force. The objectives of the test were as follows: dynamic response, DAF and damping factor determination; measurement of the strain oscillations in the key's base and in the weld seam; comparison of the measured data with computation results. The paper will present the analytical grounds of the testing conditions, test facility description, analytical adaptation of the facility, experimental results, its comparison with analysis and discussion, and guidelines for the next experimental phase.

  18. Improved method for SNR prediction in machine-learning-based test

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    This paper applies an improved method for testing the signal-to-noise ratio (SNR) of Analogue-to-Digital Converters (ADC). In previous work, a noisy and nonlinear pulse signal is exploited as the input stimulus to obtain the signature results of ADC. By applying a machine-learning-based approach,

  19. Steady state gamma testing of a 4K NMOS dynamic RAM

    International Nuclear Information System (INIS)

    Coleman, D.W.; Temkin, B.M.

    1976-01-01

    Samples of the Texas Instruments TMS4060JL, 4096 bit dynamic random-access memory (4K RAM) were tested in the ionizing environment of a 137 Ce source. Irradiated in an active condition, the devices were observed to fail at 1 x 10 3 rads (Si). Twenty-four hours after irradiation, 4 of the 5 devices tested were again functional. The devices were not powered and were at room temperature during the 24 hour anneal period

  20. Automated X-ray television complex for testing large dynamic objects

    International Nuclear Information System (INIS)

    Gusev, E.A.; Luk'yanenko, Eh.A.; Chelnokov, V.B.; Kuleshov, V.K.; Alkhimov, Yu.V.

    1992-01-01

    An automated X-ray television complex on the base of matrix gas-dischage large-area (2.1x1.0 m) converter for testing large cargoes and containers, as well as for inductrial article diagnostics is described. The complex pulsed operation with the 512 kbytes television digital memory unit provides for testing dynamic objects under minimal doses (20-100 μR)

  1. The mechanical design and dynamic testing of the IBEX-H1 electrostatic analyzer spacecraft instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, John D [Los Alamos National Laboratory; Baca, Allen G [SNL

    2009-01-01

    This paper presents the mechanical design, fabrication and dynamic testing of an electrostatic analyzer spacecraft instrument. The functional and environmental requirements combined with limited spacecraft accommodations, resulted in complex component geometries, unique material selections, and difficult fabrication processes. The challenging aspects of the mechanical design and several of the more difficult production processes are discussed. In addition, the successes, failures, and lessons learned from acoustic and random vibration testing of a full-scale prototype instrument are presented.

  2. Full-scale locomotive dynamic collision testing and correlations : offset collisions between a locomotive and a covered hopper car (test 4).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision test with rail vehicles as part of the Federal Railroad Administrations research program on improved crashworthiness of locomotive structures. ...

  3. Testing an Idealized Dynamic Cascade Model of the Development of Serious Violence in Adolescence

    Science.gov (United States)

    Dodge, Kenneth A.; Greenberg, Mark T.; Malone, Patrick S.

    2008-01-01

    A dynamic cascade model of development of serious adolescent violence was proposed and tested through prospective inquiry with 754 children (50% male; 43% African American) from 27 schools at 4 geographic sites followed annually from kindergarten through Grade 11 (ages 5-18). Self, parent, teacher, peer, observer, and administrative reports…

  4. Test and simulation of dynamic phase compensation from Mita-Teknik A/S

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Iov, F.; Blaabjerg, F.

    2004-01-01

    This report describes the test of a dynamic phase compensation unit for a wind turbine with directly connected induction generators. The compensation unit is based on thyristor switched capacitors, where conventional wind turbine compensations usemechanical contactors to switch the capacitors. Th...

  5. Test and simulation of dynamic phase compensation from Mita-Teknik A/S

    DEFF Research Database (Denmark)

    Soerensen, P.; Iov, Florin; Blaabjerg, Frede

    This report describes the test of a dynamic phase compensation unit or a wind turbine with directly connected induction generators. The compensation unit is based on thyristor switched capacitors, where conventional wind turbine compensations use mechanical contactors to switch the capacitors. Th...

  6. Explanatory item response modeling of children's change on a dynamic test of analogical reasoning

    NARCIS (Netherlands)

    Stevenson, C.E.; Hickendorff, M.; Resing, W.C.M.; Heiser, W.J.; de Boeck, P.A.L.

    Dynamic testing is an assessment method in which training is incorporated into the procedure with the aim of gauging cognitive potential. Large individual differences are present in children's ability to profit from training in analogical reasoning. The aim of this experiment was to investigate

  7. [Development and testing of theories of population dynamics]. First annual report

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, W.W.; Bence, J.R.; McCauley, E.; Nisbet, R.M.

    1990-03-15

    We report new analyses to test competing models of the Daphnia/algal interaction. Our model is good at predicting equilibrium algal densities, and if our new insights can account for stability in this system across a wide range of natural environments, this may contribute to understanding predator-prey dynamics in general.

  8. Dynamic Testing, Working Memory, and Reading Comprehension Growth in Children with Reading Disabilities

    Science.gov (United States)

    Swanson, H. Lee

    2011-01-01

    This longitudinal study assessed (a) whether performance changes in working memory (WM) as a function of dynamic testing were related to growth in reading comprehension and (b) whether WM performance among subgroups of children with reading disabilities (RD; children with RD only, children with both reading and arithmetic deficits, and low verbal…

  9. Time-Varying Dynamic Properties of Offshore Wind Turbines Evaluated by Modal Testing

    DEFF Research Database (Denmark)

    Damgaard, Mads; Andersen, J. K. F.; Ibsen, Lars Bo

    2014-01-01

    resonance of the wind turbine structure. In this paper, free vibration tests and a numerical Winkler type approach are used to evaluate the dynamic properties of a total of 30 offshore wind turbines located in the North Sea. Analyses indicate time-varying eigenfrequencies and damping ratios of the lowest...

  10. Subcategorization of Suspicious Breast Lesions (BI-RADS Category 4) According to MRI Criteria: Role of Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging.

    Science.gov (United States)

    Maltez de Almeida, João Ricardo; Gomes, André Boechat; Barros, Thomas Pitangueira; Fahel, Paulo Eduardo; de Seixas Rocha, Mário

    2015-07-01

    The purposes of this study were to investigate whether dynamic contrast-enhanced MRI is adequate for subcategorization of suspicious lesions (BI-RADS category 4) and to evaluate whether use of DWI improves diagnostic performance. The study group was composed of 103 suspicious lesions found in 83 subjects. Patient ages and lesion sizes were compiled, and two radiologists reanalyzed the images; subcategorized the findings as BI-RADS 4A, 4B, or 4C; and calculated apparent diffusion coefficient (ADC) values. The stratified variables were tested by univariate analysis and inserted in two multivariate predictive models, which were used to generate ROC curves and compare AUCs. Positive predictive values (PPVs) for each subcategory and ADC level were calculated, and interobserver agreement was tested. Forty-four (42.7%) suspicious findings proved malignant. Except for age (p = 0.08), all stratified predictor variables were significant in univariate analyses (p BI-RADS 4 subcategory (4A, 0.15; 4B, 0.37; 4C, 0.84). ADC values of 1.10 × 10(-3) mm(2)/s or less had the second highest PPV (0.77). Interobserver agreement was substantial at a kappa value of 0.80 (95% CI, 0.70-0.90; p BI-RADS category 4) can be satisfactorily performed with DCE-MRI and slightly improved when DWI is introduced.

  11. The research of a new test method about dynamic target infrared spectral signature

    Science.gov (United States)

    Wu, Jiang-hui; Gao, Jiao-bo; Chen, Qing; Luo, Yan-ling; Li, Jiang-jun; Gao, Ze-dong; Wang, Nan; Gao, Meng

    2014-11-01

    The research on infrared spectral target signature shows great military importance in the domain of IR detection Recognition, IRCM, IR image guide and ir stealth etc. The measurements of infrared spectral of tactical targets have been a direct but effective technique in providing signatures for both analysis and simulation to missile seeker designers for many years. In order to deal with the problem of dynamic target infrared spectral signature, this paper presents a new method for acquiring and testing ir spectral radiation signatures of dynamic objects, which is based on an IR imager guiding the target and acquiring the scene at the same time, a FOV chopping scan infrared spectral radiometer alternatively testing the target and its background around ir spectral signature.ir imager and spectral radiometer have the same optical axis. The raw test data was processed according to a new deal with method. Principles and data processing methods were described in detail, test error also analyzed. Field test results showed that the method described in the above is right; the test error was reduced smaller, and can better satisfy the needs of acquiring dynamic target ir spectral signature.

  12. Algorithm for evaluation of parameters of ionization chamber signals from the flash-ADC date

    International Nuclear Information System (INIS)

    Baturin, V.N.; Balin, D.V.; Maev, E.M.; Petrov, G.E.; Semenchuk, G.G.

    1991-01-01

    An algorithm for evaluation of parameters of pulses obtained from the ionization chamber (IC) and digitized by Flash-ADC is described. It was designed for determination of the energies and times of arrival of charged particles in DTμ catalyzed fusion that occurs in the IC sensitive volume, in order to measure directly the probability of muon sticking. The algorithm provides the extraction of weak pulses of sloped muon with 50% efficiency, the measurement of fusion energy, especially for long and low amplitude pulses, the recognition of pulse pileups, using special shape analysis procedure. The algorithm was tuned with a special electronic hardware that supplied sequences of pulses with specified amplitudes, durations and shapes and simulation of simulated tritium-noise background. 6 refs.; 7 figs.; 1 tab

  13. Cryocooled wideband digital channelizing radio-frequency receiver based on low-pass ADC

    International Nuclear Information System (INIS)

    Vernik, Igor V; Kirichenko, Dmitri E; Dotsenko, Vladimir V; Miller, Robert; Webber, Robert J; Shevchenko, Pavel; Talalaevskii, Andrei; Gupta, Deepnarayan; Mukhanov, Oleg A

    2007-01-01

    We have demonstrated a digital receiver performing direct digitization of radio-frequency signals over a wide frequency range from kilohertz to gigahertz. The complete system, consisting of a cryopackaged superconductor all-digital receiver (ADR) chip followed by room-temperature interface electronics and a field programmable gate array (FPGA) based post-processing module, has been developed. The ADR chip comprises a low-pass analog-to-digital converter (ADC) delta modulator with phase modulation-demodulation architecture together with digital in-phase and quadrature mixer and a pair of digital decimation filters. The chip is fabricated using a 4.5 kA cm -2 process and is cryopackaged using a commercial-off-the-shelf cryocooler. Experimental results in HF, VHF, UHF and L bands and their analysis, proving consistent operation of the cryopackaged ADR chip up to 24.32 GHz clock frequency, are presented and discussed

  14. Automated Defect Classification (ADC) and Progression Monitoring (DPM) in wafer fab reticle requalification

    Science.gov (United States)

    Yen, T. H.; Lai, Rick; Tuo, Laurent C.; Tolani, Vikram; Chen, Dongxue; Hu, Peter; Yu, Jiao; Hwa, George; Zheng, Yan; Lakkapragada, Suresh; Wang, Kechang; Peng, Danping; Wang, Bill; Chiang, Kaiming

    2013-09-01

    As optical lithography continues to extend into low-k1 regime, resolution of mask patterns continue to diminish, and so do mask defect requirements due to increasing MEEF. Post-inspection, mask defects have traditionally been classified by operators manually based on visual review. This approach may have worked down to 65/55nm node layers. However, starting 45nm and smaller nodes, visually reviewing 50 to sometimes 100s of defects on masks with complex modelbased OPC, SRAF, and ILT geometries, is error-prone and takes up valuable inspection tool capacity. Both these shortcomings in manual defect review are overcome by adoption of the computational solution called Automated Defect Classification (ADC) wherein mask defects are accurately classified within seconds and consistent to guidelines used by production technicians and engineers.

  15. ADF/ADC Web Tools for Browsing and Visualizing Astronomical Catalogs and NASA Astrophysics Mission Metadata

    Science.gov (United States)

    Shaya, E.; Kargatis, V.; Blackwell, J.; Borne, K.; White, R. A.; Cheung, C.

    1998-05-01

    Several new web based services have been introduced this year by the Astrophysics Data Facility (ADF) at the NASA Goddard Space Flight Center. IMPReSS is a graphical interface to astrophysics databases that presents the user with the footprints of observations of space-based missions. It also aids astronomers in retrieving these data by sending requests to distributed data archives. The VIEWER is a reader of ADC astronomical catalogs and journal tables that allows subsetting of catalogs by column choices and range selection and provides database-like search capability within each table. With it, the user can easily find the table data most appropriate for their purposes and then download either the subset table or the original table. CATSEYE is a tool that plots output tables from the VIEWER (and soon AMASE), making exploring the datasets fast and easy. Having completed the basic functionality of these systems, we are enhancing the site to provide advanced functionality. These will include: market basket storage of tables and records of VIEWER output for IMPReSS and AstroBrowse queries, non-HTML table responses to AstroBrowse type queries, general column arithmetic, modularity to allow entrance into the sequence of web pages at any point, histogram plots, navigable maps, and overplotting of catalog objects on mission footprint maps. When completed, the ADF/ADC web facilities will provide astronomical tabled data and mission retrieval information in several hyperlinked environments geared for users at any level, from the school student to the typical astronomer to the expert datamining tools at state-of-the-art data centers.

  16. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (pTest-retest reliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  17. Natural Circulation High Pressure Loop Dynamics Around Operating Point, Tests and Modelling With Retran 02

    International Nuclear Information System (INIS)

    Masriera, N.A; Doval, A.S; Mazufri, C.M

    2000-01-01

    The Natural Circulation High Pressure Loop (CAPCN) reproduces in scale all the one-dimensional thermal-hydraulic phenomena occurring in the primary loop of CAREM-25 reactor.It plays an important role in the qualification process of calculating computer codes.This facility demanded to develop several technological solutions in order to achieve the measuring and control quality required by that process.This engineering and experimental development allowed completing the first stage of dynamic tests during 1998.The trends of recorded data were systematically evaluated in terms of the deviations of main variables in response to different perturbations.By this analysis a group of eight transients was selected, providing a Minimum Representative Set (MRS) of dynamic tests, allowing the evaluation of all dynamic phenomena.Each of these transients was simulated with RETRAN-02, using a spreadsheet to facilitate the consistent elaboration and modification of input files.Comparing measured data and computer simulations, it may be concluded that it is possible to reproduce the dynamic response of all the transients with a level of approximation quite homogeneous and generally acceptable.It is possible to identify the detailed physical models that fit better the dynamic phenomena, and which of the limitations of RETRAN code are more relevant

  18. Implementation and Test of the Automatic Flight Dynamics Operations for Geostationary Satellite Mission

    Directory of Open Access Journals (Sweden)

    Sangwook Park

    2009-12-01

    Full Text Available This paper describes the Flight Dynamics Automation (FDA system for COMS Flight Dynamics System (FDS and its test result in terms of the performance of the automation jobs. FDA controls the flight dynamics functions such as orbit determination, orbit prediction, event prediction, and fuel accounting. The designed FDA is independent from the specific characteristics which are defined by spacecraft manufacturer or specific satellite missions. Therefore, FDA could easily links its autonomous job control functions to any satellite mission control system with some interface modification. By adding autonomous system along with flight dynamics system, it decreases the operator’s tedious and repeated jobs but increase the usability and reliability of the system. Therefore, FDA is used to improve the completeness of whole mission control system’s quality. The FDA is applied to the real flight dynamics system of a geostationary satellite, COMS and the experimental test is performed. The experimental result shows the stability and reliability of the mission control operations through the automatic job control.

  19. Nonlinear elastic behavior of rocks revealed by dynamic acousto-elastic testing

    Science.gov (United States)

    Shokouhi, Parisa; Riviere, Jacques; Guyer, Robert; Johnson, Paul

    2017-04-01

    Nonlinear elastic behavior of rocks is studied at the laboratory scale with the goal of illuminating observations at the Earth scale, for instance during strong ground motion and earthquake slip processes. A technique called Dynamic Acousto-Elastic Testing (DAET) is used to extract the nonlinear elastic response of disparate rocks (sandstone, granite and soapstone). DAET is the dynamic analogous to standard (quasi-static) acousto-elastic testing. It consists in measuring speed of sound with high-frequency low amplitude pulses (MHz range) across the sample while it is dynamically loaded with a low frequency, large amplitude resonance (kHz range). This particular configuration provides the instantaneous elastic response over a full dynamic cycle and reveals unprecedented details: instantaneous softening, tension/compression asymmetry as well as hysteretic behaviors. The strain-induced modulation of ultrasonic pulse velocities ('fast dynamics') is analyzed to extract nonlinearity parameters. A projection method is used to extract the harmonic content and a careful comparison of the fast dynamics response is made. In order to characterize the rate of elastic recovery ('slow dynamics'), we continue to monitor the ultrasonic wave velocity for about 30 minutes after the low-frequency resonance is turned off. In addition, the frequency, pressure and humidity dependences of the nonlinear parameters are reported for a subset of samples. We find that the nonlinear components can be clustered into two categories, which suggests that two main mechanisms are at play. The first one, related to the second harmonic, is likely related to the opening/closing of microstructural features such as cracks and grain/grain contacts. In contrast, the second mechanism is related to all other nonlinear parameters (transient softening, hysteresis area and higher order harmonics) and may arise from shearing mechanisms at grain interfaces.

  20. Ground test program for a full-size solar dynamic heat receiver

    Science.gov (United States)

    Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.

    1991-01-01

    Test hardware, facilities, and procedures were developed to conduct ground testing of a full-size, solar dynamic heat receiver in a partially simulated, low earth orbit environment. The heat receiver was designed to supply 102 kW of thermal energy to a helium and xenon gas mixture continuously over a 94 minute orbit, including up to 36 minutes of eclipse. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber using liquid nitrogen cold shrouds and an aperture cold plate. Special test equipment was designed to provide the required ranges in interface boundary conditions that typify those expected or required for operation as part of the solar dynamic power module on the Space Station Freedom. The support hardware includes an infrared quartz lamp heater with 30 independently controllable zones and a closed-Brayton cycle engine simulator to circulate and condition the helium-xenon gas mixture. The test article, test support hardware, facilities, and instrumentation developed to conduct the ground test program are all described.

  1. A Low-Power High-Dynamic-Range Receiver System for In-Probe 3-D Ultrasonic Imaging.

    Science.gov (United States)

    Attarzadeh, Hourieh; Xu, Ye; Ytterdal, Trond

    2017-10-01

    In this paper, a dual-mode low-power, high dynamic-range receiver circuit is designed for the interface with a capacitive micromachined ultrasonic transducer. The proposed ultrasound receiver chip enables the development of an in-probe digital beamforming imaging system. The flexibility of having two operation modes offers a high dynamic range with minimum power sacrifice. A prototype of the chip containing one receive channel, with one variable transimpedance amplifier (TIA) and one analog to digital converter (ADC) circuit is implemented. Combining variable gain TIA functionality with ADC gain settings achieves an enhanced overall high dynamic range, while low power dissipation is maintained. The chip is designed and fabricated in a 65 nm standard CMOS process technology. The test chip occupies an area of 76[Formula: see text] 170 [Formula: see text]. A total average power range of 60-240 [Formula: see text] for a sampling frequency of 30 MHz, and a center frequency of 5 MHz is measured. An instantaneous dynamic range of 50.5 dB with an overall dynamic range of 72 dB is obtained from the receiver circuit.

  2. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    International Nuclear Information System (INIS)

    Lucon, E.

    2008-01-01

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  3. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-09-15

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  4. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  5. Factors underlying anxiety in HIV testing: risk perceptions, stigma, and the patient-provider power dynamic.

    Science.gov (United States)

    Worthington, Catherine; Myers, Ted

    2003-05-01

    Client anxiety is often associated with diagnostic testing. In this study, the authors used a grounded theory approach to examine the situational and social factors underlying anxiety associated with HIV testing, analyzing transcripts from semistructured interviews with 39 HIV test recipients in Ontario, Canada (selected based on HIV serostatus, risk experience, geographic region, gender, and number of HIV tests), then integrating emergent themes with existing research literature. Analysis revealed four themes: perceptions of risk and responsibility for health, stigma associated with HIV, the patient-provider power dynamic, and techniques used by test recipients to enhance control in their interactions with providers. Service implications include modifications to information provision during the test session, attention to privacy and anonymity, and sensitivity to patient-provider interactions.

  6. Evaluation of seismic behavior of soils under nuclear containment structures via dynamic centrifuge test

    International Nuclear Information System (INIS)

    Ha, Jeong Gon; Kim, Dong-Soo

    2014-01-01

    Highlights: • A series of dynamic centrifuge tests were performed for NPP structure to investigate the soil–foundation-structure interaction with various soil conditions from loose sand to weathered rock. • SFSI phenomena for NPP structure were observed directly using experimental method. • Effect of the soil stiffness and nonlinear characteristics on SFSI was estimated. • There are comparisons of the control motions for seismic design of a NPP structure. • Subsoil condition, earthquake intensity and control motion affected to seismic load. - Abstract: To evaluate the earthquake loads for the seismic design of a nuclear containment structure, it is necessary to consider the soil–foundation-structure interaction (SFSI) due to their interdependent behavior. Especially, understanding the effects of soil stiffness under the structure and the location of control motion to SFSI are very important. Motivated by these requirements, a series of dynamic centrifuge tests were performed with various soil conditions from loose sand to weathered rock (WR), as well as different seismic intensities for the bedrock motion. The different amplification characteristics in peak-accelerations profile and effects of soil-nonlinearity in response spectrum were observed. The dynamic behaviors were compared between surface of free-field and foundation of the structure for the evaluation of the control motion for seismic design. It was found that dynamic centrifuge test has potentials to estimate the seismic load considering SFSI

  7. A modern artificial intelligence Playware art tool for psychological testing of group dynamics

    DEFF Research Database (Denmark)

    Pagliarini, Luigi; Lund, Henrik Hautop

    2015-01-01

    We describe an artistic method used for the psychological analysis of group dynamics. The design of the artistic system, which mediates group dynamics, emerges from our studies of modular Playware and remixing Playware. Inspired from remixing modular Playware, where users remix samples in the form...... and the psychological findings. We describe the modern artificial intelligence implementation of this instrument. Between an art piece and a psychological test, at a first cognitive analysis, it seems to be a promising research tool. In the discussion we speculate about potential industrial applications, as well....

  8. Constructive Design and Dynamic Testing of the Double Harmonic Gear Transmission

    Directory of Open Access Journals (Sweden)

    Sava Ianici

    2015-07-01

    Full Text Available The paper presents the design construction and functioning of a new type of harmonic gear transmission named double harmonic gear transmission (D.H.G.T.. In the second part of this paper is presented the dynamic testing of the double harmonic gear transmission, which is based on the results of the experimental researches on the D.H.G.T. The authors present the results of experimental research, enabling a scientific interpretation of the dynamic behaviour of the D.H.G.T., on the mechanical efficiency and the stress state of flexible wheel.

  9. DYNAMIC TENSILE TESTING WITH A LARGE SCALE 33 MJ ROTATING DISK IMPACT MACHINE

    OpenAIRE

    Kussmaul , K.; Zimmermann , C.; Issler , W.

    1985-01-01

    A recently completed testing machine for dynamic tensile tests is described. The machine consists essentially of a pendulum which holds the specimen and a large steel disk with a double striking nose fixed to its circumference. Disk diameter measures 2000 mm, while its mass is 6400 kg. The specimens to be tested are tensile specimens with a diameter of up to 20 mm and 300 mm length or CT 15 specimens at various temperatures. Loading velocity ranges from 1 to 150 m/s. The process of specimen-n...

  10. Dynamic analysis of a low energy test house and a central heating system

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, L. H.

    1996-12-01

    This report is concerned with the description and the modelling of the heat transfer in a test house at the Department of Buildings and Energy (IBE) at the Technical University of Denmark (DTU). The test house is a single-storeyed low energy house and it is fairly well known due to some previously performed experiments. A water-based central heating system is used as heating system. The report presents the preliminary analysis of the heat dynamics in the test house heating experiment. Input sequences to the water based central heating system are designed. (au) 21 refs.

  11. Correlation of In Vivo and Ex Vivo ADC and T2 of In Situ and Invasive Murine Mammary Cancers

    Science.gov (United States)

    Fan, Xiaobing; Macleod, Kay; Mustafi, Devkumar; Conzen, Suzanne D.; Markiewicz, Erica; Zamora, Marta; Vosicky, James; Mueller, Jeffrey; Karczmar, Gregory S.

    2015-01-01

    Ex vivo MRI may aid in the evaluation of surgical specimens, and provide valuable information regarding the micro-anatomy of mammary/breast cancer. The use of ex vivo MRI to study mouse mammary cancer would be enhanced if there is a strong correlation between parameters derived from in vivo and ex vivo scans. Here, we report the correlation between apparent diffusion coefficient (ADC) and T2 values measured in vivo and ex vivo in mouse mammary glands with in situ cancers (mammary intraepithelial neoplasia (MIN)) and invasive cancers (those which spread outside the ducts into surrounding tissue). MRI experiments were performed on the Polyoma middle T oncoprotein breast cancer mouse model (n = 15) in a 9.4T scanner. For in vivo experiments, T2-weighted (T2W) images were acquired to identify abnormal regions, then ADC and T2 values were measured for nine selected slices. For ex vivo experiments, a midline incision was made along the spine, and then skin, glands, and tumors were gently peeled from the body. Tissue was fixed in formalin, placed around a mouse-sized sponge, and sutured together mimicking the geometry of the gland when attached to the mouse. The same pulse sequences used for in vivo experiments were repeated for ex vivo scans at room temperature. Regions of interest were manually traced on T2W images defining features that could be identified on in vivo and ex vivo images. The results demonstrate a strong positive correlations between in vivo and ex vivo invasive cancers for ADC (r = 0.89, p vivo and ex vivo in situ cancers for ADC (r = 0.61, p vivo ADC value was about 54% of the in vivo value; and the average ex vivo T2 was similar to the in vivo value for cancers. Although motion, fixation, and temperature differences affect ADC and T2, these results show a reliable relationship between ADC and T2 in vivo and ex vivo. As a result ex vivo images can provide valuable information with clinical and research applications. PMID:26208092

  12. Comparison of ADC map with trace map in the normal and infarct areas of the brains of stroke patients

    International Nuclear Information System (INIS)

    Kim, Seung Hyung; Yoon, Pyeong Ho; Jeong, Eun Kee; Oh, Young Taick; Kim, Dong Ik

    1999-01-01

    To compare ADC mapping with trace mapping in normal and infarct areas of the brains of stroke patients. Eighteen patients diagnosed on the basis of clinical and brain MRI examinations as suffering from brain infarction were included in this study (hyperacute-1, acute-4, subacute-12, chronic-1). Diffusion weighted images of three orthogonal directions of a patient's brain were obtained by means of a single shot EPI pulse sequence, using a diffusion gradient with four serial b-factors. Three ADC maps were then reconstructed by post-image processing and were summed pixel by pixel to yield a trace map. ROIs were selected in the normal areas of white matter, gray matter and CSF of one hemisphere, and other ROIs of the same size were selected at the same site of the contralateral hemisphere. ADC and trace values were measured and right/left ratios of ADC and trace values were calculated. Using these values, we then compared the ADC map with the trace map, and compared the degree of anisotropic diffusion between white matter, gray matter and CSF. Except for three, whose infarct lesions were small and lay over white and gray matter, patients were divided into two groups. Those with infarct in the white matter (n=10) were assigned to one group, and those with infarct in the gray matter (n=5) to the other. ROIs were selected in the infarct area and other ROIs of the same size were selected at the same site of the contralateral hemisphere. ADC and trace values were measured and infarct/contralateral ratios were calculated. We then compared ADC ratio with trace ratio in white matter and gray matter infarct. In normal white matter, the Dxx ratio was 0.980±0.098, the Dyy ratio 1.019±0.086, the Dzz ratio 0.999±0.111, and the trace ratio 0.995±0.031. In normal gray matter, the Dxx ratio was 1.001±0.058, the Dyy ratio 0.996±0.063, Dzz ratio 1.005±0.070, and the trace ratio 1.001±0.028. In CSF, the Dxx ratio was 1.002±0.064, the Dyy ratio 1.023±0.055, the Dzz ratio 0.999

  13. The longitudinal effect of ejaculation on seminal vesicle fluid volume and whole-prostate ADC as measured on prostate MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Tristan; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Tanner, James; Gill, Andrew B.; Slough, Rhys A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Wason, James [University of Cambridge, MRC Biostatistics Unit, Cambridge (United Kingdom)

    2017-12-15

    To prospectively investigate the longitudinal effect of ejaculatory abstinence on MRI-measured seminal vesicle (SV) volume and whole-prostate ADC over consecutive days. 15 healthy male volunteers (mean 35.9 years, range 27-53) underwent 3-T MRI at baseline and 1, 2 and 3 days post-ejaculation. Prostate and SV volumes were derived by volume segmentation and whole-gland apparent diffusion coefficient (ADC) values calculated. A mixed-effects linear regression compared ADC values and prostate/seminal vesicle volumes in each volunteer between studies in a pairwise manner. All subjects completed the four MRIs. Mean prostate volume was 22.45 cm{sup 3} (range 13.04-31.21 cm{sup 3}), with no change between the four studies (p = 0.89-0.99). 13/15 subjects showed SV volume reduction from baseline to day 1, with group-mean decreasing from 6.45 to 4.80 cm{sup 3} (-25.6%, p < 0.001), and a significant reduction from baseline to day 2 (-18.1%, p = 0.002). There was a significant volume increase from both day 1 (+21.3%, p = 0.006) and day 2 (+10.2%, p = 0.022) to day 3 post-ejaculation. There was a significant reduction in ADC from 1.105 at baseline to 1.056 x 10{sup -3} mm{sup 2}/s at day 1 (mean -4.3%, p = 0.009). The longitudinal effect of ejaculation on SV volume was demonstrated. Significant reductions in SV volume and whole-gland ADC were observed post-ejaculation, supporting a 3-day period of abstinence before prostate MRI. (orig.)

  14. Study of the optical properties and the carbonaceous clusters in DAM-ADC solid state nuclear track detectors

    Science.gov (United States)

    Rammah, Y. S.; Abdalla, A. M.

    2017-12-01

    The optical properties of DAM-ADC solid state nuclear track detectors (SSNTDs) were investigated. Samples of DAM-ADC detector were irradiated at room temperature with gamma doses in the range of 100-500 kGy using 1.25 MeV 60Co source of dose rate 4 kGy/h. The optical characterization of these detectors have been studied through the measurements of UV-visible absorption spectra of blank and γ- irradiated samples. The optical energy band gaps, Eg for the detectors were obtained from the direct and the indirect allowed transitions in K-space using two methods (Tauc's model and absorption spectrum fitting (ASF) method). The absorbance of DAM-ADC detector was found to increase with increasing of the gamma absorbed dose. The width of the tail of localized states in the band gap, Eu was evaluated with the Urbach's method. The number of carbon atoms per conjugated length (N), the number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Both of the direct and the indirect band gaps of DAM-ADC detector decrease with increasing of the gamma absorbed dose. Urbach's energy decreased significantly for the detector. An increase in N, M, and n with increasing of the gamma absorbed dose was noticed. Results shed light on the effect of gamma irradiations of DAM-ADC SSNTDs to suitable industrial applications and to modify the optical properties through gamma-induced modifications of the polymer structure.

  15. Low-Speed Dynamic Wind Tunnel Test Analysis of a Generic 53 Degree Swept UCAV Configuration With Controls

    Science.gov (United States)

    Vicroy, Dan D.; Huber, Kerstin C.; Rohlf, Detlef; Loser, Thomas

    2014-01-01

    Several static and dynamic forced-motion wind tunnel tests have been conducted on a generic unmanned combat air vehicle (UCAV) configuration with a 53deg swept leading edge. These tests are part of an international research effort to assess and advance the state-of-art of computational fluid dynamics (CFD) methods to predict the static and dynamic stability and control characteristics for this type of configuration. This paper describes the dynamic forced motion data collected from two different models of this UCAV configuration as well as analysis of the control surface deflections on the dynamic forces and moments.

  16. Electron cloud dynamics in the Cornell Electron Storage Ring Test Accelerator wiggler

    Directory of Open Access Journals (Sweden)

    C. M. Celata

    2011-04-01

    Full Text Available The interference of stray electrons (also called “electron clouds” with accelerator beams is important in modern intense-beam accelerators, especially those with beams of positive charge. In magnetic wigglers, used, for instance, for transverse emittance damping, the intense synchrotron radiation produced by the beam can generate an electron cloud of relatively high density. In this paper the complicated dynamics of electron clouds in wigglers is examined using the example of a wiggler in the Cornell Electron Storage Ring Test Accelerator experiment at the Cornell Electron Storage Ring. Three-dimensional particle-in-cell simulations with the WARP-POSINST computer code show different density and dynamics for the electron cloud at locations near the maxima of the vertical wiggler field when compared to locations near the minima. Dynamics in these regions, the electron cloud distribution vs longitudinal position, and the beam coherent tune shift caused by the wiggler electron cloud will be discussed.

  17. Econometric testing on linear and nonlinear dynamic relation between stock prices and macroeconomy in China

    Science.gov (United States)

    Borjigin, Sumuya; Yang, Yating; Yang, Xiaoguang; Sun, Leilei

    2018-03-01

    Many researchers have realized that there is a strong correlation between stock prices and macroeconomy. In order to make this relationship clear, a lot of studies have been done. However, the causal relationship between stock prices and macroeconomy has still not been well explained. A key point is that, most of the existing research adopts linear and stable models to investigate the correlation of stock prices and macroeconomy, while the real causality of that may be nonlinear and dynamic. To fill this research gap, we investigate the nonlinear and dynamic causal relationships between stock prices and macroeconomy. Based on the case of China's stock prices and acroeconomy measures from January 1992 to March 2017, we compare the linear Granger causality test models with nonlinear ones. Results demonstrate that the nonlinear dynamic Granger causality is much stronger than linear Granger causality. From the perspective of nonlinear dynamic Granger causality, China's stock prices can be viewed as "national economic barometer". On the one hand, this study will encourage researchers to take nonlinearity and dynamics into account when they investigate the correlation of stock prices and macroeconomy; on the other hand, our research can guide regulators and investors to make better decisions.

  18. Approximating Matsubara dynamics using the planetary model: Tests on liquid water and ice

    Science.gov (United States)

    Willatt, Michael J.; Ceriotti, Michele; Althorpe, Stuart C.

    2018-03-01

    Matsubara dynamics is the quantum-Boltzmann-conserving classical dynamics which remains when real-time coherences are taken out of the exact quantum Liouvillian [T. J. H. Hele et al., J. Chem. Phys. 142, 134103 (2015)]; because of a phase-term, it cannot be used as a practical method without further approximation. Recently, Smith et al. [J. Chem. Phys. 142, 244112 (2015)] developed a "planetary" model dynamics which conserves the Feynman-Kleinert (FK) approximation to the quantum-Boltzmann distribution. Here, we show that for moderately anharmonic potentials, the planetary dynamics gives a good approximation to Matsubara trajectories on the FK potential surface by decoupling the centroid trajectory from the locally harmonic Matsubara fluctuations, which reduce to a single phase-less fluctuation particle (the "planet"). We also show that the FK effective frequency can be approximated by a direct integral over these fluctuations, obviating the need to solve iterative equations. This modification, together with use of thermostatted ring-polymer molecular dynamics, allows us to test the planetary model on water (gas-phase, liquid, and ice) using the q-TIP4P/F potential surface. The "planetary" fluctuations give a poor approximation to the rotational/librational bands in the infrared spectrum, but a good approximation to the bend and stretch bands, where the fluctuation lineshape is found to be motionally narrowed by the vibrations of the centroid.

  19. Hydraulically driven control rod concept for integral reactors: fluid dynamic simulation and preliminary test

    International Nuclear Information System (INIS)

    Ricotti, M.E.; Cammi, A.; Lombardi, C.; Passoni, M.; Rizzo, C.; Carelli, M.; Colombo, E.

    2003-01-01

    The paper deals with the preliminary study of the Hydraulically Driven Control Rod concept, tailored for PWR control rods (spider type) with hydraulic drive mechanism completely immersed in the primary water. A specific solution suitable for advanced versions of the IRIS integral reactor is under investigation. The configuration of the Hydraulic Control Rod device, made up by an external movable piston and an internal fixed cylinder, is described. After a brief description of the whole control system, particular attention is devoted to the Control Rod characterization via Computational Fluid Dynamics (CFD) analysis. The investigation of the system behavior, including dynamic equilibrium and stability properties, has been carried out. Finally, preliminary tests were performed in a low pressure, low temperature, reduced length experimental facility. The results are compared with the dynamic control model and CFD simulation model, showing good agreement between simulations and experimental data. During these preliminary tests, the control system performs correctly, allowing stable dynamic equilibrium positions for the Control Rod and stable behavior during withdrawal and insertion steps. (author)

  20. The behaviour of a vehicle’s suspension system on dynamic testing conditions

    Science.gov (United States)

    Mihon, L.; Lontiş, N.; Deac, S.

    2018-01-01

    The paper presents a car suspension’s behaviour on dynamic testing conditions through theoretical and mathematical simulation on specific model, on the single traction wheel, according to the real vehicle and by experiment on the test bench by reproducing the road’s geometry and vehicle’s speed and measuring the acceleration and damping response of the suspension system on that wheel. There are taking in consideration also the geometry and properties of the tyre-wheel model and physical wheel’s properties. The results are important due to the suspension’s model properties which allows to extend the theory and applications to the whole vehicle for improving the vehicle’s dynamics.

  1. Dynamic testing at high strain rates of an ultrafine-grained magnesium alloy processed by ECAP

    Energy Technology Data Exchange (ETDEWEB)

    Li, B., E-mail: bli@jhu.edu [Center for Advanced Metallic and Ceramic Systems, Johns Hopkins University, Baltimore, MD 21218 (United States); Joshi, S. [Center for Advanced Metallic and Ceramic Systems, Johns Hopkins University, Baltimore, MD 21218 (United States); Department of Mechanical Engineering, National University of Singapore, Singapore 117576 (Singapore); Azevedo, K.; Ma, E.; Ramesh, K.T. [Center for Advanced Metallic and Ceramic Systems, Johns Hopkins University, Baltimore, MD 21218 (United States); Figueiredo, R.B. [Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA 90089-1453 (United States); Department of Materials Science, University of Southern California, Los Angeles, CA 90089-1453 (United States); Langdon, T.G. [Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA 90089-1453 (United States); Department of Materials Science, University of Southern California, Los Angeles, CA 90089-1453 (United States); Materials Research Group, School of Engineering Sciences, University of Southampton, Southampton SO17 1BJ (United Kingdom)

    2009-08-20

    A ZK60 magnesium alloy was processed by equal-channel angular pressing (ECAP) at 473 K to produce a grain size of {approx}0.8 {mu}m and it was then tested under dynamic conditions at strain rates up to 4.0 x 10{sup 3} s{sup -1} using a split-Hopkinson bar. The stress-strain curves in dynamic testing exhibited upwards concave curvature suggesting the occurrence of twinning. Examination by transmission electron microscopy showed that dislocation slip played a major role in the flow behavior with dislocation accumulation as the main source of work hardening. An identification of Burgers vectors revealed the extensive presence of prismatic dislocations. Rod-shaped Mg{sub 1}(Zn,Zr){sub 1} precipitates present in the as-received alloy become fragmented and overaged during ECAP.

  2. Dynamic fracture tests for flawed nuclear piping and validation of LBB evaluation method

    International Nuclear Information System (INIS)

    Kashima, K.

    1998-01-01

    The international research program, 'IPIRG program', was proposed and managed by U.S. Nuclear Regulatory Commission from 1987 to 1996 to develop a fracture database and validate fracture mechanics technology for assessing the integrity of flawed nuclear piping. Seventeen Japanese organizations, including utilities companies, vendors and CRIEPI (the representative) jointly participated in the program. Many full-scale fracture tests, using US and Japanese pipes, were conducted under dynamic and cyclic loadings, simulating seismic conditions. The results from tests on Japanese pipes showed that the current LBB (Leak-Before-Break) evaluation method for Japanese pipes, originally developed and demonstrated for relatively small-diameter pipes subjected to quasi-static loading, could also be applied to large-diameter pipes and dynamic loading. (author)

  3. Simulation of IST Turbomachinery Power-Neutral Tests with the ANL Plant Dynamics Code

    Energy Technology Data Exchange (ETDEWEB)

    Moisseytsev, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Sienicki, J. J. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-13

    The validation of the Plant Dynamics Code (PDC) developed at Argonne National Laboratory (ANL) for the steady-state and transient analysis of supercritical carbon dioxide (sCO2) systems has been continued with new test data from the Naval Nuclear Laboratory (operated by Bechtel Marine Propulsion Corporation) Integrated System Test (IST). Although data from three runs were provided to ANL, only two of the data sets were analyzed and described in this report. The common feature of these tests is the power-neutral operation of the turbine-compressor shaft, where no external power through the alternator was provided during the tests. Instead, the shaft speed was allowed to change dictated by the power balance between the turbine, the compressor, and the power losses in the shaft. The new test data turned out to be important for code validation for several reasons. First, the power-neutral operation of the shaft allows validation of the shaft dynamics equations in asynchronous mode, when the shaft is disconnected from the grid. Second, the shaft speed control with the compressor recirculation (CR) valve not only allows for testing the code control logic itself, but it also serves as a good test for validation of both the compressor surge control and the turbine bypass control actions, since the effect of the CR action on the loop conditions is similar for both of these controls. Third, the varying compressor-inlet temperature change test allows validation of the transient response of the precooler, a shell-and-tube heat exchanger. The first transient simulation of the compressor-inlet temperature variation Test 64661 showed a much slower calculated response of the precooler in the calculations than the test data. Further investigation revealed an error in calculating the heat exchanger tube mass for the PDC dynamic equations that resulted in a slower change in the tube wall temperature than measured. The transient calculations for both tests were done in two steps. The

  4. A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions.

    Directory of Open Access Journals (Sweden)

    Sven Herrmann

    Full Text Available Constant high rates of dislocation-related complications of total hip replacements (THRs show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients.

  5. Blended-Wing-Body Low-Speed Flight Dynamics: Summary of Ground Tests and Sample Results

    Science.gov (United States)

    Vicroy, Dan D.

    2009-01-01

    A series of low-speed wind tunnel tests of a Blended-Wing-Body tri-jet configuration to evaluate the low-speed static and dynamic stability and control characteristics over the full envelope of angle of attack and sideslip are summarized. These data were collected for use in simulation studies of the edge-of-the-envelope and potential out-of-control flight characteristics. Some selected results with lessons learned are presented.

  6. A Novel Method for Dynamic Short-Beam Shear Testing of 3D Woven Composites

    Science.gov (United States)

    2011-08-11

    Sudarshan TS, Radhakrishnan R, Gao X-L (2007) Dynamic indentation response of fine grained boron carbide . Journal of the American Ceramic Society 90(6):1850...tiles were then cut using a high speed diamond sectioning saw into the desired test coupons with approximate dimensions of 50 mm×20 mm. The 20 mm... anvil which serves to support the specimen and the force sensors. The bar material is a pre- cipitation hardened steel which has high yield strength

  7. Dynamic stiffness testing-based flutter analysis of a fin with an actuator

    Directory of Open Access Journals (Sweden)

    Zhang Renjia

    2015-10-01

    Full Text Available Engineering-oriented modeling and synthesized modeling of the fin-actuator system of a missile fin are introduced, including mathematical modeling of the fin, motor and multi-stage gear reducer. The fin-actuator model is verified using dynamic stiffness testing. Good agreement is achieved between the test and theoretical results. The parameter-variable analysis indicates that the inertia of the motor rotor, reduction ratio of the reducer, connection stiffness and damping between the actuator and fin shaft have significant impacts on the dynamic stiffness characteristics. In flutter analysis, test data are directly used in the frequency domain method and indirectly used in the time domain method through the updated fin-actuator model. The two methods play different roles in engineering applications but are of equal importance. The results indicate that dynamic stiffness and constant stiffness treatments may lead to completely different flutter characteristics. Attention should be paid to the design of the fin-actuator system of a missile.

  8. Testing the sustainability of the Croatian military forces: A system dynamics approach

    Directory of Open Access Journals (Sweden)

    Emil Tustanovski

    2015-03-01

    Full Text Available In line with global trends, the Croatian military is currently going through a transformation, but is being stifled by a long recession and negative demographic trends. The purpose of this article is to outline the possibilities of applying system dynamics models in testing the sustainability of the Croatian military forces (CMF with respect to their size and composition. The article mainly focuses on the demographic trends and their implications on the CMF. After a brief exposition of the research done in this field to date, the article presents two developed models – a demographic model and a military recruitment model. The models were carefully tested using validation tests suitable for system dynamics modelling. Subsequent to validation, the models were merged into a single integral system dynamics model of the CMF. Three experiments were conducted based on different fertility values, and the impact of demographic trends, which emerge from the different fertility levels. The results of the simulation, based on demographic data from the 2011 Census, as well as estimated data, though not accessible at the time, suggest that the Croatian military will encounter difficulties in meeting its demands for recruits in the next 20-30 years. Further implications of current demographic trends on the CMF’s sustainability are discussed towards the end of the paper. Since basic inputs for any organization are labor and capital, the problem is addressed from two complementary perspectives: a demographic and a financial perspective.

  9. Control and Testing of a Dynamic Voltage Restorer (DVR) at Medium Voltage Level

    DEFF Research Database (Denmark)

    Nielsen, John Godsk; Newman, Michael; Nielsen, Hans Ove

    2004-01-01

    power sensitive loads from voltage sags. This paper reports practical test results obtained on a medium voltage (10 kV) level using a DVR at a Distribution test facility in Kyndby, Denmark. The DVR was designed to protect a 400-kVA load from a 0.5-p.u. maximum voltage sag. The reported DVR verifies......The dynamic voltage restorer (DVR) has become popular as a cost effective solution for the protection of sensitive loads from voltage sags. Implementations of the DVR have been proposed at both a low voltage (LV) level, as well as a medium voltage (MV) level; and give an opportunity to protect high...

  10. Biphasic time course of brain water ADC observed during the first month of life in term neonates with severe perinatal asphyxia is indicative of poor outcome at 3 years.

    Science.gov (United States)

    Boichot, Christophe; Mejean, Nathalie; Gouyon, Jean Bernard; Brunotte, François; Walker, Paul Michael

    2011-02-01

    In severe perinatal asphyxia, the prognostic value of apparent diffusion coefficient (ADC) measurements is still open to question. We hypothesized that temporal and anatomical changes of brain ADC values occurring early after the hypoxic-ischemic insult could predict the outcome at 36 months. To demonstrate this, mean ADC values were calculated for 16 brain structures in 59 term neonates who underwent an MR examination during the first month of life. Neonates were divided into two groups according to their 36-month outcome: unfavorable (death/severe disability) or favorable outcome. ADC values were plotted against age at scan. In neonates with favorable outcomes (n=32), ADC values were constant over the study period. In babies with unfavorable outcomes (n=27), ADCs exhibited two different patterns. In infratentorial structures, ADCs were constant and normal. In supratentorial areas, ADCs followed a biphasic temporal evolution: ADC values were at their lowest at day 2, showed a rapid increase until Days 5-7, and were thereafter similar to those of neonates with favorable outcomes. Using receiver operating characteristic analysis, during the first 3-5 days of life, all neonates with decreased ADC had an unfavorable outcome. These temporal and anatomical changes of ADC values imply that individual prognosis of asphyxiated neonates can only be predicted by measurement of ADC in supratentorial areas within the first 3-5 days of life. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Static and dynamic testing of a damaged post tensioned concrete beam

    Directory of Open Access Journals (Sweden)

    Limongelli M.P.

    2015-01-01

    Full Text Available In this paper are reported the results of an experimental campaign carried out on a post tensioned concrete beam with the aim of investigating the possibility to detect early warning signs of deterioration basing on static and/or dynamic tests. The beam was tested in several configurations aimed to reproduce several different phases of the ‘life’ of the beam: the original undamaged state, increasing loss of tension in the post tensioning cables, a strengthening intervention carried out by means of a second tension cable, formation of further cracks on the strengthened beam. Responses of the beam were measured by an extensive set of instruments consisting of accelerometers, inclinometers, displacement transducers, strain gauges and optical fibres. The paper discusses the tests program and the dynamic characterization of the beam in the different damage scenarios. The modal properties of the beam in the different phases were recovered basing on the responses recorded on the beam during sine-sweep and impact hammer tests. The variation of the first modal frequency was studied to investigate the sensitivity of this parameter to both the cracking of the concrete section and the tension in the cables and also to compare results given by different types of experimental tests.

  12. Dynamic simulation of a fuel cell hybrid vehicle during the federal test procedure-75 driving cycle

    International Nuclear Information System (INIS)

    Kang, Sanggyu; Min, Kyoungdoug

    2016-01-01

    Highlights: • Development of a FCHV dynamic model. • Integration of a PEMFC system dynamic model with the electric vehicle model. • Investigation of the dynamic behavior of the FCEV and PEMFC system during FTP-75. • Capturing the dynamic correlation among components in PEMFC system during FTP-75. - Abstract: The dynamic behavior of a proton exchange membrane fuel cell (PEMFC) system is a crucial factor to ensure the safe and effective operation of fuel cell hybrid vehicles (FCHVs). Specifically, water and thermal management are critical to stabilize the performance of the PEMFC during severe load changes. In the present study, the FCHV dynamic model is developed. The dynamic model of the PEMFC system developed by Matlab–Simulink® is integrated into the electric vehicle model embedded in the Amesim®. The dynamic model of the PEMFC system is composed of a PEMFC stack, an air feeding system, and a thermal management system (TMS). The component models of PEMFC, a shell-and-tube gas-to-gas membrane humidifier, and a heat exchanger are validated via a comparison with the experimental data. The FCHV model is simulated during a federal test procedure (FTP)-75 driving cycle. One system configuration and control strategy is adopted to attain optimal water and thermal management in the PEMFC system. The vehicle speed obtained from the FCHV model aptly tracks the target velocity profile of the FTP-75 cycle within an error of ±0.5%. The dynamic behavior and correlation of each component in the PEMFC system is investigated. The mass and heat transfer in the PEMFC, a humidifier, and a heat exchanger are resolved to determine the species concentration and the temperature more accurately with discretization in the flow’s perpendicular direction. Discretization in the flow parallel direction of humidifier and heat exchanger model makes it possible to capture the distribution of the characteristics. The present model can be used to attain the optimization of the system

  13. MR imaging of primary sclerosing cholangitis - Additional value of diffusion-weighted imaging and ADC measurement

    Energy Technology Data Exchange (ETDEWEB)

    Djokicc Kovac, Jelena [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia)], e-mail: jelenadjokic2003@yahoo.co.uk; Maksimovic, Ruzica [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Jesic, Rada [Clinic for Gastroenterohepatology, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Stanisavljevic, Dejana [Inst. for Statistics, Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Kovac, Bojan [Military Medical Academy, Belgrade (Serbia)

    2013-04-15

    Background: Primary sclerosing cholangitis (PSC) is a cholestatic liver disease with chronic inflammation and progressive destruction of biliary tree. Magnetic resonance (MR) examination with diffusion-weighted imaging (DWI) allows analysis of morphological liver parenchymal changes and non-invasive assessment of liver fibrosis. Moreover, MR cholangiopancreatography (MRCP), as a part of standard MR protocol, provides insight into bile duct irregularities. Purpose: To evaluate MR and MRCP findings in patients with primary sclerosing cholangitis and to determine the value of DWI in the assessment of liver fibrosis. Material and Methods: The following MR findings were reviewed in 38 patients: abnormalities in liver parenchyma signal intensity, changes in liver morphology, lymphadenopathy, signs of portal hypertension, and irregularities of intra- and extrahepatic bile ducts. Apparent diffusion coefficient (ADC) was calculated for six locations in the liver for b = 800 s/mm{sup 2}. Results: T2-weighted hyperintensity was seen as peripheral wedge-shaped areas in 42.1% and as periportal edema in 28.9% of patients. Increased enhancement of liver parenchyma on arterial-phase imaging was observed in six (15.8%) patients. Caudate lobe hypertrophy was present in 10 (26.3%), while spherical liver shape was noted in 7.9% of patients. Liver cirrhosis was seen in 34.2% of patients; the most common pattern was micronodular cirrhosis (61.5%). Other findings included lymphadenopathy (28.9%), signs of portal hypertension (36.7%), and bile duct irregularities (78.9%). The mean ADCs (x10{sup -3} mm{sup 2}/s) were significantly different at stage I vs. stages III and IV, and stage II vs. stage IV. No significant difference was found between stages II and III. For prediction of stage {>=}II and stage {>=}III, areas under receiver-operating characteristic curves were 0.891 and 0.887, respectively. Conclusion: MR with MRCP is a necessary diagnostic procedure for diagnosis of PSC and

  14. Computational fluid dynamics analysis of the Canadian deuterium uranium moderator tests at the Stern Laboratories Inc.

    Directory of Open Access Journals (Sweden)

    Hyoung Tae Kim

    2015-04-01

    Full Text Available A numerical calculation with the commercial computational fluid dynamics code CFX-14.0 was conducted for a test facility simulating the Canadian deuterium uranium moderator thermal–hydraulics. Two kinds of moderator thermal–hydraulic tests at Stern Laboratories Inc. were performed in the full geometric configuration of the Canadian deuterium uranium moderator circulating vessel, which is called a calandria tank, housing a matrix of horizontal rod bundles simulating calandria tubes. The first of these tests is the pressure drop measurement of a cross flow in the horizontal rod bundles. The other is the local temperature measurement on the cross section of the horizontal cylinder vessel simulating the calandria system. In the present study, the full geometric details of the calandria tank are incorporated in the grid generation of the computational domain to which the boundary conditions for each experiment are applied. The numerical solutions are reviewed and compared with the available test data.

  15. Computational fluid dynamics analysis of the Canadian deuterium uranium moderator tests at the stern laboratories inc

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Tae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Chang, Se Myong [Kunsan National University, Gunsan (Korea, Republic of)

    2015-04-15

    A numerical calculation with the commercial computational fluid dynamics code CFX-14.0 was conducted for a test facility simulating the Canadian deuterium uranium moderator thermal hydraulics. Two kinds of moderator thermal hydraulic tests at Stern Laboratories Inc. were performed in the full geometric configuration of the Canadian deuterium uranium moderator circulating vessel, which is called a calandria tank, housing a matrix of horizontal rod bundles simulating calandria tubes. The first of these tests is the pressure drop measurement of a cross flow in the horizontal rod bundles. The other is the local temperature measurement on the cross section of the horizontal cylinder vessel simulating the calandria system. In the present study, the full geometric details of the calandria tank are incorporated in the grid generation of the computational domain to which the boundary conditions for each experiment are applied. The numerical solutions are reviewed and compared with the available test data.

  16. Method of dynamic tests of peripheral elements of the Univac 1108

    International Nuclear Information System (INIS)

    Terrenoire, Philippe

    1972-01-01

    This research thesis addresses maintenance tests to be implemented for high power computers (in this case a Univac 1108) and to be performed during exploitation in order not to interrupt it. After a presentation of the hardware (central processing unit, central memory, auxiliary memories, spooler), and some generalities on programming (memory protection, addressing, statement format, indexing, index register, available library, assembler, and so on), the author describes the characteristics of a specific executable file implemented on the computer. He analyzes problems raised by maintenance of a computer and of its peripheral devices, describes the operation and logical organisation of the dynamic test procedure, reports the development of tests, and modifications introduced to run the procedure. After a description of the test execution, the author analyses lessons learned and proposes some development perspectives, discusses the specific issue of the central unit, and the problem of remote control of a set of installations

  17. Development of Drop/Shock Test in Microelectronics and Impact Dynamic Analysis for Uniform Board Response

    Science.gov (United States)

    Kallolimath, Sharan Chandrashekar

    For the past several years, many researchers are constantly developing and improving board level drop test procedures and specifications to quantify the solder joint reliability performance of consumer electronics products. Predictive finite element analysis (FEA) by utilizing simulation software has become widely acceptable verification method which can reduce time and cost of the real-time test process. However, due to testing and metrological limitations it is difficult not only to simulate exact drop condition and capture critical measurement data but also tedious to calibrate the system to improve test methods. Moreover, some of the important ever changing factors such as board flexural rigidity, damping, drop height, and drop orientation results in non-uniform stress/strain distribution throughout the test board. In addition, one of the most challenging tasks is to quantify uniform stress and strain distribution throughout the test board and identify critical failure factors. The major contributions of this work are in the four aspects of the drop test in electronics as following. First of all, an analytical FEA model was developed to study the board natural frequencies and responses of the system with the consideration of dynamic stiffness, damping behavior of the material and effect of impact loading condition. An approach to find the key parameters that affect stress and strain distributions under predominate mode responses was proposed and verified with theoretical solutions. Input-G method was adopted to study board response behavior and cut boundary interpolation methods was used to analyze local model solder joint stresses with the development of global/local FEA model in ANSYS software. Second, no ring phenomenon during the drop test was identified theoretically when the test board was modeled as both discrete system and continuous system. Numerical analysis was then conducted by FEA method for detailed geometry of attached chips with solder

  18. On protection of Freedom's solar dynamic radiator from the orbital debris environment. Part 2: Further testing and analyses

    Science.gov (United States)

    Rhatigan, Jennifer L.; Christiansen, Eric L.; Fleming, Michael L.

    1991-01-01

    Presented here are results of a test program undertaken to further define the response of the solar dynamic radiator to hypervelocity impact (HVI). Tests were conducted on representative radiator panels (under ambient, nonoperating conditions) over a range of velocity. Target parameters are also varied. Data indicate that analytical penetration predictions are conservative (i.e., pessimistic) for the specific configuration of the solar dynamic radiator. Test results are used to define the solar dynamic radiator reliability with respect to HVI more rigorously than previous studies. Test data, reliability, and survivability results are presented.

  19. On protection of Freedom's solar dynamic radiator from the orbital debris environment. II - Further testing and analyses

    Science.gov (United States)

    Rhatigan, Jennifer L.; Christiansen, Eric L.; Fleming, Michael L.

    1992-01-01

    Presented here are results of a test program undertaken to further define the response of the solar dynamic radiator to hypervelocity impact (HVI). Tests were conducted on representative radiator panels (under ambient, nonoperating conditions) over a range of velocity. Target parameters are also varied. Data indicate that analytical penetration predictions are conservative (i.e., pessimistic) for the specific configuration of the solar dynamic radiator. Test results are used to define the solar dynamic radiator reliability with respect to HVI more rigorously than previous studies. Test data, reliability, and survivability results are presented.

  20. Induction of the Arginine Decarboxylase ADC2 Gene Provides Evidence for the Involvement of Polyamines in the Wound Response in Arabidopsis1

    Science.gov (United States)

    Perez-Amador, Miguel A.; Leon, Jose; Green, Pamela J.; Carbonell, Juan

    2002-01-01

    Polyamines are small ubiquitous molecules that have been involved in nearly all developmental processes, including the stress response. Nevertheless, no direct evidence of a role of polyamines in the wound response has been described. We have studied the expression of genes involved in polyamine biosynthesis in response to mechanical injury. An increase in the expression of the arginine decarboxylase 2 (ADC2) gene in response to mechanical wounding and methyl jasmonate (JA) treatment in Arabidopsis was detected by using DNA microarray and RNA gel-blot analysis. No induction was observed for the ADC1 gene or other genes coding for spermidine and spermine synthases, suggesting that ADC2 is the only gene of polyamine biosynthesis involved in the wounding response mediated by JA. A transient increase in the level of free putrescine followed the increase in the mRNA level for ADC2. A decrease in the level of free spermine, coincident with the increase in putrescine after wounding, was also observed. Abscisic acid effected a strong induction on ADC2 expression and had no effect on ADC1 expression. Wound-induction of ADC2 mRNA was not prevented in the JA-insensitive coi1 mutant. The different pattern of expression of ADC2 gene in wild-type and coi1 mutant might be due to the dual regulation of ADC2 by abscisic acid and JA signaling pathways. This is the first direct evidence of a function of polyamines in the wound-response, and it opens a new aspect of polyamines in plant biology. PMID:12428010

  1. A new dynamic visual acuity test to assess peripheral vestibular function.

    Science.gov (United States)

    Vital, Domenic; Hegemann, Stefan C A; Straumann, Dominik; Bergamin, Oliver; Bockisch, Christopher J; Angehrn, Dominik; Schmitt, Kai-Uwe; Probst, Rudolf

    2010-07-01

    To evaluate a novel test for dynamic visual acuity (DVA) that uses an adaptive algorithm for changing the size of Landolt rings presented during active or passive head impulses, and to compare the results with search-coil head impulse testing. Prospective study in healthy individuals and patients with peripheral vestibular deficits. Tertiary academic center. One hundred neuro-otologically healthy individuals (age range, 19-80 years) and 15 patients with bilateral (n = 5) or unilateral (n = 10) peripheral vestibular loss (age range, 27-72 years). Testing of static visual acuity (SVA), DVA during active and passive horizontal head rotations (optotype presentation at head velocities >100 degrees/s and >150 degrees/s), and quantitative horizontal head impulse testing with scleral search coils. Difference between SVA and DVA, that is, visual acuity loss (VA loss), gain of the high-acceleration vestibulo-ocular reflex. Passive head impulses and higher velocities were more effective than active impulses and lower velocities. Using passive head impulses and velocities higher than 150 degrees/s, the DVA test discriminated significantly (P test sensitivity was 100%, specificity was 94%, and accuracy was 95%, with search-coil head impulse testing used as a reference. In healthy individuals, VA loss increased significantly with age (P testing with Landolt rings that are adaptively changed in size enables detection of peripheral vestibular dysfunction in a fast and simple way.

  2. Generic Issue 113 dynamic qualification and testing of large bore hydraulic snubbers

    International Nuclear Information System (INIS)

    Ware, A.G.; Nitzel, M.E.; Rahl, T.E.; Edson, J.L.; Page, J.D.

    1989-01-01

    The reliability of large bore hydraulic snubbers (LBHSs) is a present safety concern in nuclear power plants LBHSs are used primarily to restrain large components such as steam generators and reactor coolant pumps during seismic events. The US Nuclear Regulatory Commission (USNRC) developed Generic Issue 113 (GI-113), Dynamic Qualification and Testing of Large Bore Hydraulic Snubbers, with the objective of evaluating the reliability of these snubbers in operating commercial nuclear power plants. For the purposes of this research, LBHSs are defined as those hydraulic snubbers with rated load capacities equal to or greater than 50 Kips. Initially there were no test machines capable of testing LBHSs for functionality, so they were exempted from surveillance testing prior to 1980. When LBHSs were later tested, numerous deficiencies, many of which would render the LBHSs inoperable, were found. This paper describes the INEL/USNRC LBHS research program whose objective is to assess the need to improve the reliability of LBHSs and to determine what, if any, requirements should be implemented to achieve necessary improvements. The program has assessed the current state of LBHSs; including types, approximate numbers and locations of LBHSs in plants; operational, maintenance and current in-service inspection and test requirements; and the availability of state-of-the-art testing equipment. An attempt was made to determine the level of environmental and dynamic qualification. Operating experience data, including information contained in the Nuclear Plant Reliability Data System and Licensee Event Reports, were summarized to determine the modes of snubber failure. The above information, along with the recommendations and conclusions generated in the final stages of the program, are currently planned to be published as a NUREG/CR in late 1989

  3. Data collection and analysis software development for rotor dynamics testing in spin laboratory

    Science.gov (United States)

    Abdul-Aziz, Ali; Arble, Daniel; Woike, Mark

    2017-04-01

    Gas turbine engine components undergo high rotational loading another complex environmental conditions. Such operating environment leads these components to experience damages and cracks that can cause catastrophic failure during flights. There are traditional crack detections and health monitoring methodologies currently being used which rely on periodic routine maintenances, nondestructive inspections that often times involve engine and components dis-assemblies. These methods do not also offer adequate information about the faults, especially, if these faults at subsurface or not clearly evident. At NASA Glenn research center, the rotor dynamics laboratory is presently involved in developing newer techniques that are highly dependent on sensor technology to enable health monitoring and prediction of damage and cracks in rotor disks. These approaches are noninvasive and relatively economical. Spin tests are performed using a subscale test article mimicking turbine rotor disk undergoing rotational load. Non-contact instruments such as capacitive and microwave sensors are used to measure the blade tip gap displacement and blade vibrations characteristics in an attempt develop a physics based model to assess/predict the faults in the rotor disk. Data collection is a major component in this experimental-analytical procedure and as a result, an upgrade to an older version of the data acquisition software which is based on LabVIEW program has been implemented to support efficiently running tests and analyze the results. Outcomes obtained from the tests data and related experimental and analytical rotor dynamics modeling including key features of the updated software are presented and discussed.

  4. Full-size solar dynamic heat receiver thermal-vacuum tests

    Science.gov (United States)

    Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.

    1991-01-01

    The testing of a full-size, 102 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test period.

  5. Mixed-Signal Hardware Security: Attacks and Countermeasures for ΔΣ ADC

    Directory of Open Access Journals (Sweden)

    Shayan Taheri

    2017-08-01

    Full Text Available Mixed-signal integrated circuits (ICs play an eminent and critical role in design and development of the embedded systems leveraged within smart weapons and military systems. These ICs can be a golden target for adversaries to compromise in order to function maliciously. In this work, we study the security aspects of a tunnel field effect transistor (TFET-based first-order one-bit delta-sigma ( Δ Σ analog to digital converter (ADC through proposing four attack and one defense models. The first attack manipulates the input signal to the Δ Σ modulator. The second attack manipulates the analog version of the modulator output bit and is triggered by the noise signal. The third attack manipulates the modulator output bit and has a controllable trigger mechanism. The fourth attack manipulates the analog version of the modulator output bit and is triggered by a victim capacitance within the chip. For the defense, a number of signal processing filters are used in order to purge the analog version of the modulator output bit for elimination of the malicious unwanted features, introduced by the attacks. According to the simulation results, the second threat model displays the strongest attack. Derived from the countermeasure evaluation, the best filter to confront the threat models is the robust regression using the least absolute residual computing method.

  6. Electron momentum spectroscopy of norbornadiene at the benchmark ADC(3) level.

    Science.gov (United States)

    Morini, Filippo; Hajgató, Balázs; Deleuze, Michael S

    2010-09-02

    An extensive study, throughout the valence region, of the electronic structure, ionization spectrum, and electron momentum distributions of norbornadiene is presented, on the ground of accurate calculations of valence one-electron and shake-up ionization energies and of the related Dyson orbitals, using one-particle Green's function (1p-GF) theory in conjunction with the so-called third-order algebraic diagrammatic construction scheme [ADC(3)]. Comparison is made with results obtained from standard (B3LYP) Kohn-Sham orbitals and measurements employing electron momentum spectroscopy, taking into account the contamination of inner- and outer-valence spectral bands by numerous shake-up states. Four relatively intense shake-up lines at 12.1, 16.4, 17.6, and 17.8 eV are found to yield recognizable spectral fingerprints in the EMS experiments. Valence bands at electron binding energies larger than 20 eV are subject to a complete breakdown of the orbital picture of ionization.

  7. A new method for nuclear ADCs using the vernier approximation technique

    International Nuclear Information System (INIS)

    Vaidya, P.P.; Gopalakrishnan, K.R.; Pethe, V.A.; Anjaneyulu, T.

    1984-01-01

    The paper describes a new method of analog-to-digital conversion. The method named the vernier approximation technique utilizes two scales made of chains of resistors sliding over each other, one being called the main scale and the other the vernier scale. The vernier scale is moved by applying the input analog voltage as a voltage shift at both ends. This voltage shift is digitized using the comparators connected between the corresponding points on main and vernier scales. All the quantization steps are derived from a single quantization step using the process of sliding and vernier scaling resulting in high differential linearity. The scheme uses a balancing technique to balance the points on the main scale with the corresponding points on the vernier scale. The scheme works with the speed of a 'sequential parallel approximation technique' giving a higher speed of operation than either the Wilkinson technique or the successive approximation technique used for nuclear ADCs. The technique gives high accuracy even with use of ordinary components such as 1% resistors. (orig.)

  8. Noise Propagation in Multiple-Input ADC-Based Measurement Systems

    Directory of Open Access Journals (Sweden)

    Bellan Diego

    2014-12-01

    Full Text Available In this paper, the complete statistical characterization of the amplitude spectrum at the output of a multiple-input ADC-based measurement system is derived under the assumption of input channels with different noise levels. In practical applications the input channels correspond to the spatial components of a vector field (e.g., magnetic/electric field. Each output spectral line represents the amplitude of the vector field at a specific frequency. Such amplitude is a random variable depending on the noise levels (internal and external noise of the input channels. Closed form analytical solution for the probability density function of the vector field amplitude is not available in the mathematical literature under the hypothesis of different noise levels. Therefore, an analytical expression for the probability density function is derived on the basis of a Laguerre series expansion. The impact of the kind of time window, the sampling frequency, and the number of samples is clearly derived and put into evidence. Approximate analytical expressions for the mean value and the variance of the vector field amplitude are also provided. Analytical results are validated by means of numerical simulations.

  9. Low power ADC with fast zero suppression for balloon-borne experiment

    International Nuclear Information System (INIS)

    Anraku, Kazuaki; Imori, Masatosi

    1993-01-01

    The article describes a low power CAMAC ADC module with fast zero suppression. The module is developed to improve data acquisition rate for a balloon-borne detector. The module is of a single CAMAC width and includes sixteen charge-to-voltage converter (QVC) channels. Each channel has its own A/D converter. The QVC outputs are digitized simultaneously. The A/D converter continues digitization for 15 μsec at longest. Then a micro-programmed sequencer, which is installed in the module, scans the channels, comparing the outputs of the A/D converters with prescribed thresholds. The outputs are stored together with channel numbers into data memory when the outputs are greater than the thresholds. The zero suppression completes in 3 μsec, and zero-suppressed data become ready within 18 μsec. The operation of the QVC circuit is repeatedly simulated on a workstation in order that the temperature dependence of the QVC circuit could be reduced without sacrificing performance

  10. Measurement Of Neutron Radius In Lead By Parity Violating Scattering Flash ADC DAQ

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Zafar [Christopher Newport Univ., Newport News, VA (United States)

    2012-06-01

    This dissertation reports the experiment PREx, a parity violation experiment which is designed to measure the neutron radius in 208Pb. PREx is performed in hall A of Thomas Jefferson National Accelerator Facility from March 19th to June 21st. Longitudionally polarized electrons at energy 1 GeV scattered at and angle of θlab = 5.8 ° from the Lead target. Beam corrected pairty violaing counting rate asymmetry is (Acorr= 594 ± 50(stat) ± 9(syst))ppb at Q2 = 0.009068GeV 2. This dissertation also presents the details of Flash ADC Data Acquisition(FADC DAQ) system for Moller polarimetry in Hall A of Thomas Jefferson National Accelerator Facility. The Moller polarimeter measures the beam polarization to high precision to meet the specification of the PREx(Lead radius experiment). The FADC DAQ is part of the upgrade of Moller polarimetery to reduce the systematic error for PREx. The hardware setup and the results of the FADC DAQ analysis are presented

  11. Analysis of dynamic deformation behavior of AZ31 using Taylor Rod on Anvil Impact Tests

    Science.gov (United States)

    Sharma, Maruwada Sukanya; Kirtley, Daniel; Gokhale, Arun; Thadhani, Naresh

    2017-06-01

    The dynamic behavior and detailed microstructural characterization of rolled magnesium alloy AZ31 is described in this work. Magnesium alloys have gained considerable importance as they possess a high strength-to-weight ratio. The goal of the current work is to provide an insight on the dynamic deformation of AZ31 magnesium alloys. Taylor rod-on-anvil impact tests have been conducted at different velocities, on rods machined along the rolling and transverse directions of the as-rolled AZ31 plate, in order to capture the effects of anisotropy on the dynamic deformation behavior. The experiments used laser beam interruption to measure the impact velocity of the samples and high-speed digital imaging to capture transient deformation states. The impacted samples showed anisotropic deformation resulting in an elliptical impact surface foot print. Additionally, detailed orientation maps and micrographs revealed extensive twinning along with some cracks on the impact faces of the samples. Quantitative microscopy revealed that the surface area per unit volume of twins at least tripled under all impact conditions. In this presentation evolution of microstructure and anisotropy in rolled AZ31 samples subjected to Taylor rod-on-anvil impact tests will be discussed.

  12. Elastic-plastic finite element analysis-to-test correlation for structures subjected to dynamic loading

    Energy Technology Data Exchange (ETDEWEB)

    Hodge, S.C.; Minicucci, J.M. [Electric Boat Corp., Groton, CT (United States)

    1997-11-01

    A test program was undertaken to demonstrate the ability of elastic-plastic finite element methods to predict dynamic inelastic response for simple structural members. Cantilever and fixed-beam specimens were tested to levels that produced plastic straining in the range of 2.0% and to 3.0% and permanent sets. Acceleration, strain, and displacement data were recorded for use in analytical correlation. Correlation analyses were performed using the ABAQUS finite element code. Results of the correlation show that current elastic-plastic analysis techniques accurately capture dynamic inelastic response (displacement, acceleration) due to rapidly applied dynamic loading. Peak elastic and inelastic surface strains are accurately predicted. To accurately capture inelastic straining near connections, a solid model, including fillet welds, is necessary. The hardening models currently available in the ABAQUS code (isotropic, kinematic) do not accurately capture inelastic strain reversals caused by specimen rebound. Analyses performed consistently underpredicted the peak strain level of the first inelastic reversal and the rebound deflection and overpredicted the permanent set of structures experiencing inelastic rebound. Based on these findings, an improved hardening model is being implemented in the ABAQUS code by the developers. The intent of this model upgrade is to improve the ability of the program to capture inelastic strain reversals and to predict permanent sets.

  13. A novel test rig to investigate under-platform damper dynamics

    Science.gov (United States)

    Botto, Daniele; Umer, Muhammad

    2018-02-01

    In the field of turbomachinery, vibration amplitude is often reduced by dissipating the kinetic energy of the blades with devices that utilize dry friction. Under-platform dampers, for example, are often placed in the underside of two consecutive turbine blades. Dampers are kept in contact with the under-platform of the respective blades by means of the centrifugal force. If the damper is well designed, vibration of blades instigate a relative motion between the under-platform and the damper. A friction force, that is a non-conservative force, arises in the contact and partly dissipates the vibration energy. Several contact models are available in the literature to simulate the contact between the damper and the under-platform. However, the actual dynamics of the blade-damper interaction have not fully understood yet. Several test rigs have been previously developed to experimentally investigate the performance of under-platform dampers. The majority of these experimental setups aim to evaluate the overall damper efficiency in terms of reduction in response amplitude of the blade for a given exciting force that simulates the aerodynamic loads. Unfortunately, the experimental data acquired on the blade dynamics do not provide enough information to understand the damper dynamics. Therefore, the uncertainty on the damper behavior remains a big issue. In this work, a novel experimental test rig has been developed to extensively investigate the damper dynamic behavior. A single replaceable blade is clamped in the rig with a specific clamping device. With this device the blade root is pressed against a groove machined in the test rig. The pushing force is controllable and measurable, to better simulate the actual centrifugal load acting on the blade. Two dampers, one on each side of the blade, are in contact with the blade under-platforms and with platforms on force measuring supports. These supports have been specifically designed to measure the contact forces on the

  14. Modeling Potential Carbon Monoxide Exposure Due to Operation of a Major Rocket Engine Altitude Test Facility Using Computational Fluid Dynamics

    Science.gov (United States)

    Blotzer, Michael J.; Woods, Jody L.

    2009-01-01

    This viewgraph presentation reviews computational fluid dynamics as a tool for modelling the dispersion of carbon monoxide at the Stennis Space Center's A3 Test Stand. The contents include: 1) Constellation Program; 2) Constellation Launch Vehicles; 3) J2X Engine; 4) A-3 Test Stand; 5) Chemical Steam Generators; 6) Emission Estimates; 7) Located in Existing Test Complex; 8) Computational Fluid Dynamics; 9) Computational Tools; 10) CO Modeling; 11) CO Model results; and 12) Next steps.

  15. Modeling the Gas Dynamics Environment in a Subscale Solid Rocket Test Motor

    Science.gov (United States)

    Eaton, Andrew M.; Ewing, Mark E.; Bailey, Kirk M.; McCool, Alex (Technical Monitor)

    2001-01-01

    Subscale test motors are often used for the evaluation of solid rocket motor component materials such as internal insulation. These motors are useful for characterizing insulation performance behavior, screening insulation material candidates and obtaining material thermal and ablative property design data. One of the primary challenges associated with using subscale motors however, is the uncertainty involved when extrapolating the results to full-scale motor conditions. These uncertainties are related to differences in such phenomena as turbulent flow behavior and boundary layer development, propellant particle interactions with the wall, insulation off-gas mixing and thermochemical reactions with the bulk flow, radiation levels, material response to the local environment, and other anomalous flow conditions. In addition to the need for better understanding of physical mechanisms, there is also a need to better understand how to best simulate these phenomena using numerical modeling approaches such as computational fluid dynamics (CFD). To better understand and model interactions between major phenomena in a subscale test motor, a numerical study of the internal flow environment of a representative motor was performed. Simulation of the environment included not only gas dynamics, but two-phase flow modeling of entrained alumina particles like those found in an aluminized propellant, and offgassing from wall surfaces similar to an ablating insulation material. This work represents a starting point for establishing the internal environment of a subscale test motor using comprehensive modeling techniques, and lays the groundwork for improving the understanding of the applicability of subscale test data to full-scale motors. It was found that grid resolution, and inclusion of phenomena in addition to gas dynamics, such as two-phase and multi-component gas composition are all important factors that can effect the overall flow field predictions.

  16. Modeling and Experimental Tests of a Mechatronic Device to Measure Road Profiles Considering Impact Dynamics

    DEFF Research Database (Denmark)

    Souza, A.; Santos, Ilmar

    2002-01-01

    of a vehicle and to test its components in laboratory. In this framework a mechanism to measure road profiles is designed and presented. Such a mechanism is composed of two rolling wheels and two long beams attached to the vehicles by means of four Kardan joints. The wheels are kept in contact to the ground...... to highlight that the aim of this device is to independently measure two road profiles, without the influence of the vehicle dynamics where the mechanism is attached. Before the mechatronic mechanism is attached to a real vehicle, its dynamic behavior must be known. A theoretical analysis of the mechanism...... predicts well the mechanism movements. However it was also experimentally observed that the contact between the wheels and the road profile is not permanent. To analyze the non-contact between the wheels and the road, the Newton-Euler´s Method is used to calculate forces and moments of reactions between...

  17. A novel test method for measuring the thermal properties of clothing ensembles under dynamic conditions

    International Nuclear Information System (INIS)

    Wan, X; Fan, J

    2008-01-01

    The dynamic thermal properties of clothing ensembles are important to thermal transient comfort, but have so far not been properly quantified. In this paper, a novel test procedure and new index based on measurements on the sweating fabric manikin-Walter are proposed to quantify and measure the dynamic thermal properties of clothing ensembles. Experiments showed that the new index is correlated to the changing rate of the body temperature of the wearer, which is an important indicator of thermal transient comfort. Clothing ensembles having higher values of the index means the wearer will have a faster changing rate of body temperature and shorter duration before approaching a dangerous thermo-physiological state, when he changes from 'resting' to 'exercising' mode. Clothing should therefore be designed to reduce the value of the index

  18. Mechanical Properties and Fractographic Analysis of High Manganese Steels After Dynamic Deformation Tests

    Directory of Open Access Journals (Sweden)

    Jabłońska M.B.

    2014-10-01

    Full Text Available Since few years many research centres conducting research on the development of high-manganese steels for manufacturing of parts for automotive and railway industry. Some of these steels belong to the group of AHS possessing together with high strength a great plastic elongation, and an ideal uniform work hardening behavior. The article presents the dynamic mechanical properties of two types of high manganese austenitic steel with using a flywheel machine at room temperature with strain rates between 5×102÷3.5×103s?–1. It was found that the both studied steels exhibit a high sensitivity Rm to the strain rate. With increasing the strain rate from 5×102 to 3.5×103s?–1 the hardening dominates the process. The fracture analysis indicate that after dynamic test both steel is characterized by ductile fracture surfaces which indicate good plasticity of investigated steels.

  19. Dynamic Sampling of Trace Contaminants During the Mission Operations Test of the Deep Space Habitat

    Science.gov (United States)

    Monje, Oscar; Valling, Simo; Cornish, Jim

    2013-01-01

    The atmospheric composition inside spacecraft during long duration space missions is dynamic due to changes in the living and working environment of crew members, crew metabolism and payload operations. A portable FTIR gas analyzer was used to monitor the atmospheric composition within the Deep Space Habitat (DSH) during the Mission Operations Test (MOT) conducted at the Johnson Space Center (JSC). The FTIR monitored up to 20 gases in near- real time. The procedures developed for operating the FTIR were successful and data was collected with the FTIR at 5 minute intervals. Not all the 20 gases sampled were detected in all the modules and it was possible to measure dynamic changes in trace contaminant concentrations that were related to crew activities involving exercise and meal preparation.

  20. Characterisation of a pneumatic muscle test station with two dynamic plants in cascade.

    Science.gov (United States)

    Serres, J L; Reynolds, D B; Phillips, C A; Rogers, D B; Repperger, D W

    2010-02-01

    Pneumatic muscle actuators (PMAs) offer significant advantages over more traditional actuators, which make them prime candidates in rehabilitation devices. A dynamic test station (DTS) is modified to demonstrate the use of a PMA for this application. The DTS includes two dynamic systems: a PMA and a DC servomotor. An overall transfer function was developed utilising characterisation data for the PMA and DC servomotor. A Tustin (bilinear) transform was performed on the overall transfer function to obtain a discrete time system. Model parameters were optimised and used to generate input voltage profiles that achieve isokinetic (constant velocity) task specifications. Percent root mean square error values (PRMSE) between the actual and ideal profiles were used to evaluate the accuracy of this method in achieving isokinetic displacement. For PMA pressures (in kPa) of 150, 350 and 550 PRMSE were 7.80, 5.40 and 2.76, respectively.

  1. Low-speed static and dynamic force tests of a generic supersonic cruise fighter configuration

    Science.gov (United States)

    Hahne, David E.

    1989-01-01

    Static and dynamic force tests of a generic fighter configuration designed for sustained supersonic flight were conducted in the Langley 30- by 60-foot tunnel. The baseline configuration had a 65 deg arrow wing, twin wing mounted vertical tails and a canard. Results showed that control was available up to C sub L,max (maximum lift coefficient) from aerodynamic controls about all axes but control in the pitch and yaw axes decreased rapidly in the post-stall angle-of-attack region. The baseline configuration showed stable lateral-directional characteristics at low angles of attack but directional stability occurred near alpha = 25 deg as the wing shielded the vertical tails. The configuration showed positive effective dihedral throughout the test angle-of-attack range. Forced oscillation tests indicated that the baseline configuration had stable damping characteristics about the lateral-directional axes.

  2. Design of a dynamic test platform for autonomous robot vision systems

    Science.gov (United States)

    Rich, G. C.

    1980-01-01

    The concept and design of a dynamic test platform for development and evluation of a robot vision system is discussed. The platform is to serve as a diagnostic and developmental tool for future work with the RPI Mars Rover's multi laser/multi detector vision system. The platform allows testing of the vision system while its attitude is varied, statically or periodically. The vision system is mounted on the test platform. It can then be subjected to a wide variety of simulated can thus be examined in a controlled, quantitative fashion. Defining and modeling Rover motions and designing the platform to emulate these motions are also discussed. Individual aspects of the design process are treated separately, as structural, driving linkages, and motors and transmissions.

  3. Standard model group, QCD subgroup - dynamics isolating and testing the elementary QCD subprocess

    International Nuclear Information System (INIS)

    Tannenbaum, M.J.

    1982-01-01

    QCD to an experimentalist is the theory of interactions of quarks and gluons. Experimentalists like QCD because QCD is analogous to QED. Thus, following Drell and others who have for many years studied the validity of QED, one has a ready-made menu for tests of QCD. There are the static and long distance tests. These topics are covered by Peter LePage in the static properties group. In this report, dynamic and short distance tests of QCD will be discussed, primarily via reactions with large transverse momenta. This report is an introduction and overview of the subject, to serve as a framework for other reports from the subgroup. In the last two sections, the author has taken the opportunity to discuss his own ideas and opinions

  4. Computer aided instrumented Charpy test applied dynamic fracture toughness evaluation system

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Niinomi, Mitsuo

    1986-01-01

    Micro computer aided data treatment system and personal computer aided data analysis system were applied to the traditional instrumented Charpy impact test system. The analysis of Charpy absorbed energy (E i , E p , E t ) and load (P y , P m ), and the evaluation of dynamic toughness through whole fracture process, i.e. J Id , J R curve and T mat was examined using newly developed computer aided instrumented Charpy impact test system. E i , E p , E t , P y and P m were effectively analyzed using moving average method and printed out automatically by micro computer aided data treatment system. J Id , J R curve and T mat could be measured by stop block test method. Then, J Id , J R curve and T mat were effectively estimated using compliance changing rate method and key curve method on the load-load point displacement curve of single fatigue cracked specimen by personal computer aided data analysis system. (author)

  5. Temperature dependence of dynamic behavior of commercially pure titanium by the compression test

    International Nuclear Information System (INIS)

    Lee, Su Min; Seo, Song Won; Park, Kyoung Joon; Min, Oak Key

    2003-01-01

    The mechanical behavior of a Commercially Pure Titanium (CP-Ti) is investigated at high temperature Split Hopkinson Pressure Bar (SHPB) compression test with high strain-rate. Tests are performed over a temperature range from room temperature to 1000 .deg. C with interval of 200 deg. C and a strain-rate range of 1900∼2000/sec. The true flow stress-true strain relations depending on temperature are achieved in these tests. For construction of constitutive equation from the true flow stress-true strain relation, parameters for the Johnson-Cook constitutive equation is determined. And the modified Johnson-Cook equation is used for investigation of behavior of flow stress in vicinity of recrystallization temperature. The modified Johnson-Cook constitutive equation is more suitable in expressing the dynamic behavior of a CP-Ti at high temperature, i.e. about recrystallization temperature

  6. A 10-bit 40MS/s Pipelined ADC in a 0.13μm CMOS Process

    CERN Document Server

    França-Santos, Hugo

    2009-01-01

    This paper presents a 10-bit analogue to digital converter (ADC) that will be integrated in a general purpose charge readout ASIC that is the new generation of mixed-mode integrated circuits for Time Projection Chamber (TPC) readout. It is based on a pipelined structure with double sampling and was implemented with switched capacitor circuits in eight 1.5-bit stages followed by a 2-bit stage. The power consumption is adjustable with the conversion rate and varies between 15 and 34mW for a 15 to 40MS/s conversion speed. The ADC occupies a silicon area of 0.7mm2 in a 0.13μm CMOS process and operates from a single 1.5V supply.

  7. Description of a4-channel FPGA-controlled ADC-based DAQ system for general purpose PMT signals

    International Nuclear Information System (INIS)

    Conde, Ruben; Salazar, Humberto; Martinez, Oscar; Villasenor, L

    2011-01-01

    We describe a general purpose data acquisition system for PMT signals. Hardware-wise it consists of a 4-channel ADC daughter board, an FPGA mother board, a GPS receiver and an atmospheric pressure sensor and a temperature sensor. The four ADC channels simultaneously sample PMT input signals with a sampling rate of 100MS/s. We have evaluated the noise of our system obtaining less than -48.6dB. This DAQ system includes a firmware suitable for pulse processing in cosmic rays applications. In particular, we describe in detail the way in which this system can be used during the commissioning and early operation phases of the High Altitude Water Cherenkov Observatory (HAWC) currently under construction at Sierra Negra in Mexico.

  8. A 10-b 50-MS/s 820- μW SAR ADC With On-Chip Digital Calibration.

    Science.gov (United States)

    Yoshioka, Masato; Ishikawa, Kiyoshi; Takayama, Takeshi; Tsukamoto, Sanroku

    2010-12-01

    This 10-b 50-MSamples/s SAR analog-to-digital converter (ADC) features on-chip digital calibration techniques, comparator offset cancellation, a capacitor digital-to-analog converter (CDAC) linearity calibration, and internal clock control to compensate for PVT variations. A split-CDAC reduces the exponential increase in the number of unit capacitors needed and enables the input load capacitance to be as small as the kT/C noise restriction. The prototype fabricated in 65 nm 1P7M complementary metal-oxide semiconductor with MIM capacitor achieves 56.6 dB SNDR at 50-MSamples/s, 25-MHz input frequency and consumes 820 μW from a 1.0-V supply, including the digital calibration circuits. The figure of merit was 29.7 fJ/conversion-step under the Nyquist condition. The ADC occupied an active area of 0.039 mm(2) .

  9. Changes in BOLD and ADC weighted imaging in acute hypoxia during sea-level and altitude adapted states

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, Henrik B.W.; Born, Alfred P.

    2005-01-01

    possible structural changes as measured by diffusion weighted imaging. Eleven healthy sea-level residents were studied after 5 weeks of adaptation to high altitude conditions at Chacaltaya, Bolivia (5260 m). The subjects were studied immediately after return to sea-level in hypoxic and normoxic conditions......, and the examinations repeated 6 months later after re-adaptation to sea-level conditions. The BOLD response, measured at 1.5 T, was severely reduced during acute hypoxia both in the altitude and sea-level adapted states (50% reduction during an average S(a)O(2) of 75%). On average, the BOLD response magnitude was 23......% lower in altitude than sea-level adaptation in the normoxic condition, but in the hypoxic condition, no significant differences were found. A small but statistically significant decrease in the apparent diffusion coefficient (ADC) was seen in some brain regions during acute hypoxia, whereas ADC...

  10. Description of a4-channel FPGA-controlled ADC-based DAQ system for general purpose PMT signals

    Energy Technology Data Exchange (ETDEWEB)

    Conde, Ruben; Salazar, Humberto; Martinez, Oscar [Facultad de Ciencias FIsico Matematicas, BUAP, Puebla (Mexico); Villasenor, L, E-mail: rbn_cnd@hotmail.com [Instituto de Fisica y Matematicas, Universidad Michoacana San Nicolas de Hidalgo, Morelia (Mexico)

    2011-04-01

    We describe a general purpose data acquisition system for PMT signals. Hardware-wise it consists of a 4-channel ADC daughter board, an FPGA mother board, a GPS receiver and an atmospheric pressure sensor and a temperature sensor. The four ADC channels simultaneously sample PMT input signals with a sampling rate of 100MS/s. We have evaluated the noise of our system obtaining less than -48.6dB. This DAQ system includes a firmware suitable for pulse processing in cosmic rays applications. In particular, we describe in detail the way in which this system can be used during the commissioning and early operation phases of the High Altitude Water Cherenkov Observatory (HAWC) currently under construction at Sierra Negra in Mexico.

  11. Diffusion tensor imaging: the normal evolution of ADC, RA, FA, and eigenvalues studied in multiple anatomical regions of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Loebel, Ulrike [University Hospital Jena, Institute of Diagnostic and Interventional Radiology, Jena (Germany); St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); Sedlacik, Jan [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); University Hospital Jena, Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena (Germany); Guellmar, Daniel [University Hospital Jena, Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena (Germany); University Hospital Jena, Biomagnetic Center, Department of Neurology, Jena (Germany); Kaiser, Werner A.; Mentzel, Hans-Joachim [University Hospital Jena, Institute of Diagnostic and Interventional Radiology, Jena (Germany); Reichenbach, Juergen R. [University Hospital Jena, Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena (Germany)

    2009-04-15

    The aim of our work was to investigate the process of myelination in healthy patients using the diffusion parameters apparent diffusion coefficient (ADC), relative anisotropy (RA), fractional anisotropy (FA), and eigenvalues. Age-dependent changes were assessed using the slope m of the fit functions that best described the data. Seventy-two patients (3 weeks-19 years) without pathological magnetic resonance imaging findings were selected from all pediatric patients scanned with diffusion tensor imaging over a 5-year period at our institution. ADC, RA, FA, and eigenvalue maps were calculated and regions of interest were selected in anterior/posterior pons, genu/splenium of corpus callosum (CC), anterior/posterior limb of internal capsule (IC), and white matter (WM) regions (frontal, temporal, parietal, occipital WM). Statistical analysis was performed using Spearman correlation coefficient and regression analysis. Mean values ranged 71.6 x 10{sup -5} to 90.3 x 10{sup -5} mm{sup 2}/s (pons/parietal WM) for ADC, 0.32-0.94 (frontal WM/CC) for RA, and 0.36-0.81 (frontal WM/splenium) for FA. Logarithmic fit functions best described the data. Strong age influences were observed for CC, pons, and parietal/frontal WM and changes were significant for all three eigenvalues, most pronounced for perpendicular eigenvalues. Changes in RA and FA differed depending on the structure anisotropy. Changes observed for ADC, RA, FA, and eigenvalues with age were consistent with previous findings. Changes detected for RA and FA varied due to the different scaling of both parameters. We found that the use of the largely linear scaled RA adds more valuable information for the assessment of age-dependent structural changes as compared to FA. Additionally, we report normative values for the diffusion parameters studied. (orig.)

  12. Novel high sensitivity poly (sulphonate-carbonate) nuclear track detector-I: poly (PECS-co-ADC)

    International Nuclear Information System (INIS)

    Mandrekar, V.K.; Kotkar, S.M.; Tilve, S.G.; Nadkarni, V.S.

    2009-01-01

    The paper describes synthesis of a novel monomer Pentaerythritol bis (allyl carbonate)bis (allyl sulphonate) (PECS) and its cast copolymerization with Allyl Diglycol Carbonate (ADC) monomer for use as solid state nuclear track detector (SSNTD). The polymer obtained was successfully used to reveal 239 Pu alpha and 252 Cf fission fragment tracks. The polymer could be conveniently etched using 6N NaOH at 70 deg C. (author)

  13. Primary central nervous system lymphoma and atypical glioblastoma: differentiation using the initial area under the curve derived from dynamic contrast-enhanced MR and the apparent diffusion coefficient

    International Nuclear Information System (INIS)

    Choi, Yoon Seong; Lee, Ho-Joon; Ahn, Sung Soo; Lee, Seung-Koo; Chang, Jong Hee; Kang, Seok-Gu; Kim, Eui Hyun; Kim, Se Hoon

    2017-01-01

    To evaluate the ability of the initial area under the curve (IAUC) derived from dynamic contrast-enhanced MR imaging (DCE-MRI) and apparent diffusion coefficient (ADC) in differentiating between primary central nervous system lymphoma (PCNSL) and atypical glioblastoma (GBM). We retrospectively identified 19 patients with atypical GBM (less than 13 % necrosis of the enhancing tumour), and 23 patients with PCNSL. The histogram parameters of IAUC at 30, 60, 90 s (IAUC30, IAUC60, and IAUC90), and ADC were compared between PCNSL and GBM. The diagnostic performances and added values of the IAUC and ADC for differentiating between PCNSL and GBM were evaluated. Interobserver agreement was assessed via intraclass correlation coefficient (ICC). The IAUC and ADC parameters were higher in GBM than in PCNSL. The 90th percentile (p90) of IAUC30 and 10th percentile (p10) of ADC showed the best diagnostic performance. Adding p90 of IAUC30 to p10 of ADC improved the differentiation between PCNSL and GBM (area under the ROC curve [AUC] = 0.886), compared to IAUC30 or ADC alone (AUC = 0.789 and 0.744; P < 0.05 for all). The ICC was 0.96 for p90 of IAUC30. The IAUC may be a useful parameter together with ADC for differentiating between PCNSL and atypical GBM. (orig.)

  14. Primary central nervous system lymphoma and atypical glioblastoma: differentiation using the initial area under the curve derived from dynamic contrast-enhanced MR and the apparent diffusion coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Seong; Lee, Ho-Joon; Ahn, Sung Soo; Lee, Seung-Koo [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seodaemun-gu, Seoul (Korea, Republic of); Chang, Jong Hee; Kang, Seok-Gu; Kim, Eui Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Seoul (Korea, Republic of); Kim, Se Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of)

    2017-04-15

    To evaluate the ability of the initial area under the curve (IAUC) derived from dynamic contrast-enhanced MR imaging (DCE-MRI) and apparent diffusion coefficient (ADC) in differentiating between primary central nervous system lymphoma (PCNSL) and atypical glioblastoma (GBM). We retrospectively identified 19 patients with atypical GBM (less than 13 % necrosis of the enhancing tumour), and 23 patients with PCNSL. The histogram parameters of IAUC at 30, 60, 90 s (IAUC30, IAUC60, and IAUC90), and ADC were compared between PCNSL and GBM. The diagnostic performances and added values of the IAUC and ADC for differentiating between PCNSL and GBM were evaluated. Interobserver agreement was assessed via intraclass correlation coefficient (ICC). The IAUC and ADC parameters were higher in GBM than in PCNSL. The 90th percentile (p90) of IAUC30 and 10th percentile (p10) of ADC showed the best diagnostic performance. Adding p90 of IAUC30 to p10 of ADC improved the differentiation between PCNSL and GBM (area under the ROC curve [AUC] = 0.886), compared to IAUC30 or ADC alone (AUC = 0.789 and 0.744; P < 0.05 for all). The ICC was 0.96 for p90 of IAUC30. The IAUC may be a useful parameter together with ADC for differentiating between PCNSL and atypical GBM. (orig.)

  15. The Accuracy of ADC Measurements in Liver Is Improved by a Tailored and Computationally Efficient Local-Rigid Registration Algorithm.

    Science.gov (United States)

    Ragheb, Hossein; Thacker, Neil A; Guyader, Jean-Marie; Klein, Stefan; deSouza, Nandita M; Jackson, Alan

    2015-01-01

    This study describes post-processing methodologies to reduce the effects of physiological motion in measurements of apparent diffusion coefficient (ADC) in the liver. The aims of the study are to improve the accuracy of ADC measurements in liver disease to support quantitative clinical characterisation and reduce the number of patients required for sequential studies of disease progression and therapeutic effects. Two motion correction methods are compared, one based on non-rigid registration (NRA) using freely available open source algorithms and the other a local-rigid registration (LRA) specifically designed for use with diffusion weighted magnetic resonance (DW-MR) data. Performance of these methods is evaluated using metrics computed from regional ADC histograms on abdominal image slices from healthy volunteers. While the non-rigid registration method has the advantages of being applicable on the whole volume and in a fully automatic fashion, the local-rigid registration method is faster while maintaining the integrity of the biological structures essential for analysis of tissue heterogeneity. Our findings also indicate that the averaging commonly applied to DW-MR images as part of the acquisition protocol should be avoided if possible.

  16. Dynamic stability test results on an 0.024 scale B-1 air vehicle

    Science.gov (United States)

    Beeman, R. R.

    1972-01-01

    Dynamic longitudinal and lateral-directional stability characteristics of the B-1 air vehicle were investigated in three wind tunnels at the Langley Research Center. The main rotary derivatives were obtained for an angle of attack range of -3 degrees to +16 degrees for a Mach number range of 0.2 to 2.16. Damping in roll data could not be obtained at the supersonic Mach numbers. The Langley 7 x 10 foot high speed tunnel, the 8 foot transonic pressure tunnel, and the 4 foot Unitary Plan wind tunnel were the test sites. An 0.024 scale light-weight model was used on a forced oscillation type balance. Test Reynolds number varied from 474,000/ft to 1,550,000/ft. through the Mach number range tested. The results showed that the dynamic stability characteristics of the model in pitch and roll were generally satisfactory up to an angle attack of about +6 degrees. In the wing sweep range from 15 to 25 degrees the positive damping levels in roll deteriorated rapidly above +2 degrees angle of attack. This reduction in roll damping is believed to be due to the onset of separation over the wing as stall is approached.

  17. The evaluation of dynamic cracking resistance of chosen casting alloys in the aspect of the impact bending test

    OpenAIRE

    J.Sadowski; T.Szykowny

    2008-01-01

    The increase of quality and durability of produced casting alloys can be evaluated on the base of material tests performed on a high level. One of such modern test methods are tests of the dynamic damage process of materials and the evaluation on the base of obtained courses F(f), F(t) of parameters of dynamic cracking resistance KId, JId, performed with the usage of instrumented Charpy pendulums. In the paper there was presented the evaluation of dynamic cracking resistance parameters of cas...

  18. High vacuum test of the dynamic components of the cyclotron dee chamber at the 224 cm variable energy cyclotron

    International Nuclear Information System (INIS)

    Chintalapudi, S.N.; Bandopadhyay, D.K.; Ghosh, D.K.; Gowariker, S.R.

    1979-01-01

    The 224 cm Variable Energy Cyclotron constructed and commissioned at Calcutta comprises a number of dynamic components in the high vacuum Dee Chamber. The static and dynamic conditions of these components have to be tested for high vacuum worthiness prior to their installation in the Dee Tank. A special set up was fabricated and used for simulating the Dee Chamber conditions and testing the components. A high vacuum of the order of 1 x 10 -5 torr was achieved under both dynamic and static conditions with and without coolant hydraulic pressures. The details of the set up, methods employed for the various tests carried out and the results obtained are described. (auth.)

  19. Computational Fluid Dynamics Analysis Success Stories of X-Plane Design to Flight Test

    Science.gov (United States)

    Cosentino, Gary B.

    2008-01-01

    Examples of the design and flight test of three true X-planes are described, particularly X-plane design techniques that relied heavily on computational fluid dynamics(CFD) analysis. Three examples are presented: the X-36 Tailless Fighter Agility Research Aircraft, the X-45A Unmanned Combat Air Vehicle, and the X-48B Blended Wing Body Demonstrator Aircraft. An overview is presented of the uses of CFD analysis, comparison and contrast with wind tunnel testing, and information derived from CFD analysis that directly related to successful flight test. Lessons learned on the proper and improper application of CFD analysis are presented. Highlights of the flight-test results of the three example X-planes are presented. This report discusses developing an aircraft shape from early concept and three-dimensional modeling through CFD analysis, wind tunnel testing, further refined CFD analysis, and, finally, flight. An overview of the areas in which CFD analysis does and does not perform well during this process is presented. How wind tunnel testing complements, calibrates, and verifies CFD analysis is discussed. Lessons learned revealing circumstances under which CFD analysis results can be misleading are given. Strengths and weaknesses of the various flow solvers, including panel methods, Euler, and Navier-Stokes techniques, are discussed.

  20. Investigation of dynamic response of HTR core and comparison with shaking table-tests

    International Nuclear Information System (INIS)

    Anderheggen, E.; Prater, E.G.; Kreis, A.

    1990-01-01

    The analytical studies and the shaking table tests have been performed with the aim of gaining a fundamental understanding of the dynamic behaviour of such core material and validating the numerical model. The dynamic analysis of a graphite pebble-bed core could be a fairly complex undertaking if all nonlinear effects were considered. However, to achieve a practicable solution the ensemble of spheres must be replaced by a statistically equivalent continuum. Based on the Hertz theories for regular configurations, the mechanical characteristics, at small shear strains, correspond to those of an isotropic nonlinear hypoelastic medium, in which the Lame constants are a function of volumetric strain. Thus, the initial modulus values depend on confining pressure, so that the medium is inhomogeneous with respect to depth. During seismic excitation the volumetric strain, and thus the moduli, will change with time. To simplify the analysis, however, a linearized form of the model has been adopted, as well as considerations concerning damping effects. The numerical simulations carried out thus far concern mainly the 1:6 rigid wall model (i.e. with a cylinder diameter of 1.5 m) investigated experimentally and take the form of a back-analysis. Subsequently, the walls were tested separately and finally the combined behaviour was investigated. To date only preliminary results for the modelling of the reflector walls have been obtained. The objectives of this paper are thus twofold. Firstly, to discuss the constitutive law and its implementation in a general purpose finite element program. Secondly, to present some preliminary results of the dynamic analysis and to compare these with data obtained from the shaking table tests. 5 refs, 2 figs, 1 tab

  1. Dynamic Holography Method for Nondestructive Testing of Optical Homogeneity of Transparent Media

    Energy Technology Data Exchange (ETDEWEB)

    Bogodaev, N. V.; Ivleva, L. I., E-mail: ivleva@ran.gpi.ru; Lykov, P. A.; Osiko, V. V.; Gordeev, A. A. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

    2010-11-15

    The potential of the dynamic holography method for testing the phase optical homogeneity of media transparent in visible light has been considered. This method is based on imaging samples in the scheme of two-wave mixing of the second-harmonic radiation of a Nd:YAG laser and image amplification in a photorefractive barium-strontium niobate crystal. Examples of identifying phase inhomogeneities at a level of 10{sup -5} cm{sup -1} and less in crystals of different compositions are presented.

  2. Analyzing and comparing the dynamic response of test reactor main workshop

    International Nuclear Information System (INIS)

    Wang Jiachun; Fu Jiyang; Cai Laizhong

    2001-01-01

    Analyzing soil-structure interaction is an important section in anti-seismic design and analysis of nuclear engineering. The factors that influence on the response of nuclear structures include the properties of earthquake, soil and structures. So the soil-structure interaction in the non-rock foundation is different from that in the surface free field. And the interaction must be considered under the anti-seismic design standard of test reactors. The FLUSH program and SASSI2000 are applied to dynamic analysis. Moreover, comparing the obtained data and diagrams draws some conclusions

  3. Dynamic analysis of the PEC fast reactor vessel: on-site tests and mathematical models

    International Nuclear Information System (INIS)

    Zola, Maurizio; Martelli, Alessandro; Maresca, Giuseppe; Masoni, Paolo; Scandola, Giani; Descleves, Pierre

    1988-01-01

    This paper presents the main features and results of the on-site dynamic tests and the related numerical analysis carried out for the PEC reactor vessel. The purpose is to provide an example of on-site testing of large components, stressing the problems encountered during the experiments, as well as in the processing phase of the test results and for the comparisons between calculations and measurements. Tests, performed by ISMES on behalf of ENEA, allowed the dynamic response of the empty vessel to be measured, thus providing data for the verification of the numerical models of the vessel supporting structure adopted in the PEC reactor-block seismic analysis. An axisymmetric model of the vessel, implemented in the vessel, implemented in the NOVAK code, had been developed in the framework of the detailed numerical studies performed by NOVATOME (again on behalf of ENEA), to check the beam schematization with fluid added mass model adopted by ANSALDO in SAP-IV and ANSYS for the reactor-block design calculations. Furthermore, a numerical model, describing vessel supporting structure in detail, was also developed by ANSALDO and implemented in the SAP-IV code. The test conditions were analysed by use of these and the design models. Comparisons between calculations and measurements showed particularly good agreement with regard to first natural frequency of the vessel and rocking stiffness of the vessel supporting structure, i.e. those parameters on which vessel seismic amplification mainly depends: this demonstrated the adequacy of the design analysis to correctly calculate the seismic motion at the PEC core diagrid. (author)

  4. METHODS OF SOIL TESTING BY UNIVERSAL DYNAMIC PROBE OF LRN & TP

    Directory of Open Access Journals (Sweden)

    SEDIN V. L.

    2016-02-01

    Full Text Available Problem statement. Nowadays the survey organizations need in facilities of light type not being produced mass.But they are necessary for the accelerated testing of soil with the possibility of use in cramped conditions. Described below probe and test procedures is one of the possible solutions to this problem. Purpose. To acquaint with a description of the constructional features and testing methods of soil dynamic universal probe, developed in the laboratory of research of nuclear and thermal power plants (LRNTP of Pridneprovsk scientific and educational institution of innovative technologies in construction. Conclusion. The proposed probe intended to determine the mechanical properties of soils and allows to provide the express assessment of the soil properties of natural foundations to explore the changes of the properties of soil foundation under the operative objects in the process of their operation. Universal feature of the probe is the possibility to use disposable standard cones and of the composite construction of hammer (if it is necessary to reduce the weight of the hammer. As well as the possibility of carrying out tests on foreign standards, in particular on standard for the SPT (Standard Probe Test. Results of probing are drawn up as a standard continuous step schedule of change of depth value of conditional dynamic resistance of soils Pq, followed by averaging schedule and calculating of weighted index of probing for each layer land constructions. This probe and the following technique, fill a niche of the lack of manual small facilities and can contribute to the expansion of technical capabilities of survey organizations.

  5. An impact test system design and its applications to dynamic buckling of a spacer grid assembly

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Sheng, E-mail: liusheng_05@126.com; Fan, Chenguang; Yang, Yiren

    2016-11-15

    This study is aimed at investigating the dynamic buckling load, dynamic stiffness, damping and buckling characteristics of the spacer grid assembly (SGA). A pendulum impact test system is designed to experiment the buckling of SGAs. Three criterions are discussed and compared to determine the buckling loads of SGAs: B-R criterion, energy criterion and extreme value criterion. Two approaches are applied to calculate the dynamic stiffness of SGAs: One method is natural period method based on the hypothesis of harmonic motion of the pendulum whose period is approximated because of the passivation and tailing of the impact force time history; and the other is energy method based on the conservation of mechanical energy. The equivalent viscous damping is defined as the resultant cause of dissipation and is obtained by the energy principle. The impact force time history loses its approximate symmetry after buckling occurs. The impact force and displacement reach their maxima almost at the same time at pre-buckling states but not post-buckling states. Vertical straps in SGA are found to be transversely shared by horizontal straps at the buckling position. The buckling of SGA results from the lack of strength of complete structure; and the strength of material has no effects on the buckling.

  6. Dynamic focusing of phased arrays for nondestructive testing: characterization and application

    International Nuclear Information System (INIS)

    Lamarre, A.; Mainguy, F.

    1999-01-01

    Recent developments in Phased Array hardware developed by R/D TECH for nondestructive testing now allow dynamic focusing on reception. This new option, borrowed from medical technology, enables a programmable, real-time array response on reception by modifying the delay line, the gain, and the activation of each element as a function of time. This technology is presented as a new powerful tool, which can extend the depth-of-field, reduce the beam spread and increase the overall signal-to-noise ratio. Implementation of dynamic focusing in Phased Array systems will present many advantages such as an increase of the Pulse Rate Frequency (PRF). The technology implies a lot of significant possibilities, but also an extensive beam characterization. Some results are presented to quantify the advantages and drawbacks of the technique in comparison with standard phased array zone focusing and conventional UT. Results are clearly demonstrating the effect of dynamic focusing on the depth-of-field, the beam spread, the signal-to-noise ratio, and the acquisition rate, both with linear and annular arrays. Therefore this technique is suitable for applications where long soundpaths and small beam divergence are required as boresonic, billet, and blade root inspections. (author)

  7. Test Particle Energization and the Anisotropic Effects of Dynamical MHD Turbulence

    Science.gov (United States)

    González, C. A.; Dmitruk, P.; Mininni, P. D.; Matthaeus, W. H.

    2017-11-01

    In this paper, we analyze the effect of dynamical three-dimensional magnetohydrodynamic (MHD) turbulence on test particle acceleration and compare how this evolving system affects particle energization by current sheet interaction, as opposed to frozen-in-time fields. To do this, we analyze the ensemble particle acceleration for static electromagnetic fields extracted from direct numerical simulations of the MHD equations, and compare it with the dynamical fields. We show that a reduction in particle acceleration in the dynamical model results from particle trapping in field lines, which forces the particles to be advected by the flow and suppresses long exposures to the strong electric field gradients that take place between structures and generate (among other effects) an efficient particle acceleration in the static case. In addition, we analyze the effect of anisotropy caused by the mean magnetic field. It is well known that for sufficiently strong external fields, the system experiences a transition toward a two-dimensional flow. This causes an increment in the size of the coherent structures, resulting in a magnetized state of the particles and a reduction in particle energization.

  8. Diffusion-weighted magnetic resonance imaging for the initial characterization of non-fatty soft tissue tumors: correlation between T2 signal intensity and ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Gay, Frederique; Blum, Alain [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Chen, Bailiang; Felblinger, Jacques [Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Zins, Marie [University Versailles St-Quentin, Versailles (France); Inserm, Centre for research in Epidemiology and Population Health (CESP), U1018, Villejuif (France); Sirveaux, Francois [Centre Chirurgical Emile Galle, Service de Chirurgie Traumatologique et Orthopedique, Nancy (France)

    2016-02-15

    To evaluate the performance of quantitative diffusion-weighted imaging (DWI) correlated with T2 signal in differentiating non-fatty benign from malignant tumors. A total of 76 patients with a histologically confirmed non-fatty soft tissue tumors (46 benign and 30 malignant) were prospectively included in this ethics committee approved study. All patients signed an informed consent and underwent MRI with DWI with two b values (0 and 600). ADC values from the solid components of these tumors were obtained and were correlated with the lesion's signal intensity on T2-weighted fat-saturated sequences. ADC values were obtained from adjacent normal muscle to allow calculation of tumor/muscle ADC ratios. There were 58 hyperintense and 18 iso or hypointense lesions. All hypointense lesions were benign. The mean ADC values for benign and malignant tumors were 1.47 ± 0.54 x 10{sup -3} and 1.17 ± 0.38 x 10{sup -3} mm{sup 2}/s respectively (p < 0.005). The mean ADC ratio in benign iso or hypointense tumors was significantly lower than that of hyperintense ones (0.76 ± 0.21 versus 1.58 ± 0.82 - p < 0.0001). An ADC ratio lower than 0.915 was highly specific for malignancy (96.4 %), whereas an ADC ratio higher than 1.32 was highly sensitive for benign lesions (90 %). ADC analysis can be useful in the initial characterization of T2 hyperintense non-fatty soft tissue masses, although this technique alone is not likely to change patient management. (orig.)

  9. Apparent Diffusion Coefficient (ADC) as a quantitative parameter in diffusion weighted MR imaging in gynecologic cancer: Dependence on b-values used

    DEFF Research Database (Denmark)

    Kallehauge, Jesper Folsted; Tanderup, Kari; Haack, Søren

    2010-01-01

    Diffusion weighted imaging (DWI) has gained interest as an imaging modality for assessment of tumor extension and response to cancer treatment. The purpose of this study is to assess the impact of the choice of b-values on the calculation of the Apparent Diffusion Coefficient (ADC) for locally ad...... advanced gynecological cancer and to estimate a stable interval of diffusion gradients that allows for best comparison of the ADC between patients and institutions....

  10. ANATOMICAL AND PHYSICAL PROPERTIESOF BISBUL WOOD (Diospyros blancoi A.DC.

    Directory of Open Access Journals (Sweden)

    Krisdianto Krisdianto

    2005-03-01

    Full Text Available Ebony (Diospyros sp.  is a heavy hardwood that is  popularly known as blackwood. Diospyros consists of over 300 species spread throughout tropics area and about 100 species occur in Indonesia. Bisbul wood (Diospyros btancoi A.DC. is one species of  streaked ebony that is locally known as 'buah mentega'.  The anatomical and physical properties of  bisbul  were studied to collect information  for wood identification  and to support appropriate use of the timber. Anatomical properties were studied from microtome sectioned samples, which have been coloured by safranin and mounted by entellan, while fiber dimensions  were studied from macerated samples.  Physical properties  of  bisbul wood studied include moisture content, density and percentage of volumetric shrinkage. Moisture content and density were studied from 20 x 20 x 20 mm samples based on wet and oven dry condition. Volumetric shrinkage was measured from dimension changes in radial, tangential and longitudinal shrinkage of 20 x 20 x 40 mm samples. The samples were measured in wet and oven dry conditions. The main anatomical characteristics to identify bisbul wood were black wood with pinkish streaked, heavy and very hard,  very fine texture, even, lustrous surface and glossy, distinct growth ring, small size of vessels, apotracheal parenchyma forming reticulate pattern. The average moisture content was 59.86 ± 2.84%,  the density average was 0.74 ± 0.04 gr/cm3  and volumetric shrinkage was 10.41±0.70%.   The higher the stem, the more moisture  content and the lower the density will be. Sapwood density was lower and had more moisture  content than heartwood. The black pinkish heavy wood, bisbul was recommended to be used for carvings, sculpture, souvenir and luxuryinterior products.

  11. Human-Robot Collaboration Dynamic Impact Testing and Calibration Instrument for Disposable Robot Safety Artifacts.

    Science.gov (United States)

    Dagalakis, Nicholas G; Yoo, Jae Myung; Oeste, Thomas

    2016-01-01

    The Dynamic Impact Testing and Calibration Instrument (DITCI) is a simple instrument with a significant data collection and analysis capability that is used for the testing and calibration of biosimulant human tissue artifacts. These artifacts may be used to measure the severity of injuries caused in the case of a robot impact with a human. In this paper we describe the DITCI adjustable impact and flexible foundation mechanism, which allows the selection of a variety of impact force levels and foundation stiffness. The instrument can accommodate arrays of a variety of sensors and impact tools, simulating both real manufacturing tools and the testing requirements of standards setting organizations. A computer data acquisition system may collect a variety of impact motion, force, and torque data, which are used to develop a variety of mathematical model representations of the artifacts. Finally, we describe the fabrication and testing of human abdomen soft tissue artifacts, used to display the magnitude of impact tissue deformation. Impact tests were performed at various maximum impact force and average pressure levels.

  12. Incorporating Vibration Test Results for the Advanced Stirling Convertor into the System Dynamic Model

    Science.gov (United States)

    Meer, David W.; Lewandowski, Edward J.

    2010-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Convertors (ASC) at NASA GRC undergo a vibration test sequence intended to simulate the vibration history that an ASC would experience when used in an ASRG for a space mission. During these tests, a data system collects several performance-related parameters from the convertor under test for health monitoring and analysis. Recently, an additional sensor recorded the slip table position during vibration testing to qualification level. The System Dynamic Model (SDM) integrates Stirling cycle thermodynamics, heat flow, mechanical mass, spring, damper systems, and electrical characteristics of the linear alternator and controller. This Paper presents a comparison of the performance of the ASC when exposed to vibration to that predicted by the SDM when exposed to the same vibration.

  13. Initial virtual flight test for a dynamically similar aircraft model with control augmentation system

    Directory of Open Access Journals (Sweden)

    Linliang Guo

    2017-04-01

    Full Text Available To satisfy the validation requirements of flight control law for advanced aircraft, a wind tunnel based virtual flight testing has been implemented in a low speed wind tunnel. A 3-degree-of-freedom gimbal, ventrally installed in the model, was used in conjunction with an actively controlled dynamically similar model of aircraft, which was equipped with the inertial measurement unit, attitude and heading reference system, embedded computer and servo-actuators. The model, which could be rotated around its center of gravity freely by the aerodynamic moments, together with the flow field, operator and real time control system made up the closed-loop testing circuit. The model is statically unstable in longitudinal direction, and it can fly stably in wind tunnel with the function of control augmentation of the flight control laws. The experimental results indicate that the model responds well to the operator’s instructions. The response of the model in the tests shows reasonable agreement with the simulation results. The difference of response of angle of attack is less than 0.5°. The effect of stability augmentation and attitude control law was validated in the test, meanwhile the feasibility of virtual flight test technique treated as preliminary evaluation tool for advanced flight vehicle configuration research was also verified.

  14. Aerodynamic Models for the Low Density Supersonic Declerator (LDSD) Supersonic Flight Dynamics Test (SFDT)

    Science.gov (United States)

    Van Norman, John W.; Dyakonov, Artem; Schoenenberger, Mark; Davis, Jody; Muppidi, Suman; Tang, Chun; Bose, Deepak; Mobley, Brandon; Clark, Ian

    2015-01-01

    An overview of pre-flight aerodynamic models for the Low Density Supersonic Decelerator (LDSD) Supersonic Flight Dynamics Test (SFDT) campaign is presented, with comparisons to reconstructed flight data and discussion of model updates. The SFDT campaign objective is to test Supersonic Inflatable Aerodynamic Decelerator (SIAD) and large supersonic parachute technologies at high altitude Earth conditions relevant to entry, descent, and landing (EDL) at Mars. Nominal SIAD test conditions are attained by lifting a test vehicle (TV) to 36 km altitude with a large helium balloon, then accelerating the TV to Mach 4 and and 53 km altitude with a solid rocket motor. The first flight test (SFDT-1) delivered a 6 meter diameter robotic mission class decelerator (SIAD-R) to several seconds of flight on June 28, 2014, and was successful in demonstrating the SFDT flight system concept and SIAD-R. The trajectory was off-nominal, however, lofting to over 8 km higher than predicted in flight simulations. Comparisons between reconstructed flight data and aerodynamic models show that SIAD-R aerodynamic performance was in good agreement with pre-flight predictions. Similar comparisons of powered ascent phase aerodynamics show that the pre-flight model overpredicted TV pitch stability, leading to underprediction of trajectory peak altitude. Comparisons between pre-flight aerodynamic models and reconstructed flight data are shown, and changes to aerodynamic models using improved fidelity and knowledge gained from SFDT-1 are discussed.

  15. Dynamic tensile tests with superimposed ultrasonic oscillations applied to stainless steel

    International Nuclear Information System (INIS)

    Schinke, B.

    1986-09-01

    For the analysis of the mechanical consequences of core disruptive accidents in Fast Breeder Reactors various computer codes have been developed in the European Community. In recent years an extensive assessment has been performed by comparing the results of these codes with explosion tests in waterfilled vessels (COVA-experiments). Common to the various codes, a systematic underestimation of the vessel strains was found. In the COVA tests high frequency pressure oscillations were observed and thus it was conjectured that the phenomenon of ''acoustic softening'' might be relevant in explaining the discrepancies in the strains. To validate this conjecture a hydro-pneumatic tensile test apparatus was developed which allows dynamic tensile testing at room temperature with and without superimposed ultrasonic oscillations (40 kHz). The mean strain rate can be varied from 5 x 10 -5 to 30 s -1 and the ultrasound intensity may amount up to 30 W/mm -2 . The test specimens were fabricated from the actual COVA sheet material (stainless steel type 321). (orig./GL) [de

  16. Testing the effects of basic numerical implementations of water migration on models of subduction dynamics

    Science.gov (United States)

    Quinquis, M. E. T.; Buiter, S. J. H.

    2014-06-01

    Subduction of oceanic lithosphere brings water into the Earth's upper mantle. Previous numerical studies have shown how slab dehydration and mantle hydration can impact the dynamics of a subduction system by allowing a more vigorous mantle flow and promoting localisation of deformation in the lithosphere and mantle. The depths at which dehydration reactions occur in the hydrated portions of the slab are well constrained in these models by thermodynamic calculations. However, computational models use different numerical schemes to simulate the migration of free water. We aim to show the influence of the numerical scheme of free water migration on the dynamics of the upper mantle and more specifically the mantle wedge. We investigate the following three simple migration schemes with a finite-element model: (1) element-wise vertical migration of free water, occurring independent of the flow of the solid phase; (2) an imposed vertical free water velocity; and (3) a Darcy velocity, where the free water velocity is a function of the pressure gradient caused by the difference in density between water and the surrounding rocks. In addition, the flow of the solid material field also moves the free water in the imposed vertical velocity and Darcy schemes. We first test the influence of the water migration scheme using a simple model that simulates the sinking of a cold, hydrated cylinder into a dry, warm mantle. We find that the free water migration scheme has only a limited impact on the water distribution after 1 Myr in these models. We next investigate slab dehydration and mantle hydration with a thermomechanical subduction model that includes brittle behaviour and viscous water-dependent creep flow laws. Our models demonstrate that the bound water distribution is not greatly influenced by the water migration scheme whereas the free water distribution is. We find that a bound water-dependent creep flow law results in a broader area of hydration in the mantle wedge, which

  17. Testing the effects of the numerical implementation of water migration on models of subduction dynamics

    Science.gov (United States)

    Quinquis, M. E. T.; Buiter, S. J. H.

    2013-10-01

    Subduction of oceanic lithosphere brings water into Earth's upper mantle. Previous numerical studies have shown how slab dehydration and mantle hydration can impact the dynamics of a subduction system by allowing a more vigorous mantle flow and promoting localisation of deformation in lithosphere and mantle. The depths at which dehydration reactions occur in the hydrated portions of the slab are well constrained in these models by thermodynamic calculations. However, the mechanism by which free water migrates in the mantle is incompletely known. Therefore, models use different numerical schemes to model the migration of free water. We aim to show the influence of the numerical scheme of free water migration on the dynamics of the upper mantle and more specifically the mantle wedge. We investigate the following three migration schemes with a finite-element model: (1) element-wise vertical migration of free water, occurring independent of the material flow; (2) an imposed vertical free water velocity; and (3) a Darcy velocity, where the free water velocity is calculated as a function of the pressure gradient between water and the surrounding rocks. In addition, the material flow field also moves the free water in the imposed vertical velocity and Darcy schemes. We first test the influence of the water migration scheme using a simple Stokes flow model that simulates the sinking of a cold hydrated cylinder into a hot dry mantle. We find that the free water migration scheme has only a limited impact on the water distribution after 1 Myr in these models. We next investigate slab dehydration and mantle hydration with a thermomechanical subduction model that includes brittle behaviour and viscous water-dependent creep flow laws. Our models show how the bound water distribution is not greatly influenced by the water migration scheme whereas the free water distribution is. We find that a water-dependent creep flow law results in a broader area of hydration in the mantle

  18. Pseudo-dynamic tests on masonry residential buildings seismically retrofitted by precast steel reinforced concrete walls

    Science.gov (United States)

    Li, Wenfeng; Wang, Tao; Chen, Xi; Zhong, Xiang; Pan, Peng

    2017-07-01

    A retrofitting technology using precast steel reinforced concrete (PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests.

  19. Experimental test of the new analytic matrix formalism for spin dynamics

    Directory of Open Access Journals (Sweden)

    V. S. Morozov

    2007-04-01

    Full Text Available We recently started testing Chao’s proposed new matrix formalism for describing the spin dynamics due to a single spin resonance. The Chao formalism is probably the first fundamental improvement of the Froissart-Stora equation in that it allows analytic calculations of the beam polarization’s behavior inside a resonance. We tested the Chao formalism using a 1.85  GeV/c polarized deuteron beam stored in COSY, by sweeping an rf dipole’s frequency through 200 Hz, while varying the distance from the sweep’s end frequency to an rf-induced spin resonance’s central frequency. Since the Froissart-Stora equation itself can make no prediction inside a resonance, we compared our experimental data with the predictions of the Chao formalism and those of an empirical two-fluid model based on the Froissart-Stora equation. The data strongly favor the Chao formalism.

  20. Structure refinement using precession electron diffraction tomography and dynamical diffraction: tests on experimental data.

    Science.gov (United States)

    Palatinus, Lukáš; Corrêa, Cinthia Antunes; Steciuk, Gwladys; Jacob, Damien; Roussel, Pascal; Boullay, Philippe; Klementová, Mariana; Gemmi, Mauro; Kopeček, Jaromír; Domeneghetti, M Chiara; Cámara, Fernando; Petříček, Václav

    2015-12-01

    The recently published method for the structure refinement from three-dimensional precession electron diffraction data using dynamical diffraction theory [Palatinus et al. (2015). Acta Cryst. A71, 235-244] has been applied to a set of experimental data sets from five different samples - Ni2Si, PrVO3, kaolinite, orthopyroxene and mayenite. The data were measured on different instruments and with variable precession angles. For each sample a reliable reference structure was available. A large series of tests revealed that the method provides structure models with an average error in atomic positions typically between 0.01 and 0.02 Å. The obtained structure models are significantly more accurate than models obtained by refinement using kinematical approximation for the calculation of model intensities. The method also allows a reliable determination of site occupancies and determination of absolute structure. Based on the extensive tests, an optimal set of the parameters for the method is proposed.

  1. Constitutive modeling of the dynamic-tensile-extrusion test of PTFE

    Science.gov (United States)

    Resnyansky, A. D.; Brown, E. N.; Trujillo, C. P.; Gray, G. T.

    2017-01-01

    Use of polymers in defense, aerospace and industrial applications under extreme loading conditions makes prediction of the behavior of these materials very important. Crucial to this is knowledge of the physical damage response in association with phase transformations during loading and the ability to predict this via multi-phase simulation accounting for thermodynamical non-equilibrium and strain rate sensitivity. The current work analyzes Dynamic-Tensile-Extrusion (Dyn-Ten-Ext) experiments on polytetrafluoroethylene (PTFE). In particular, the phase transition during loading and subsequent tension are analyzed using a two-phase rate sensitive material model implemented in the CTH hydrocode. The calculations are compared with experimental high-speed photography. Deformation patterns and their link with changing loading modes are analyzed numerically and correlated to the test observations. It is concluded that the phase transformation is not as critical to the response of PTFE under Dyn-Ten-Ext loading as it is during the Taylor rod impact testing.

  2. Method of Increasing Identification Accuracy under Experimental Tests of Dynamic Objects

    Directory of Open Access Journals (Sweden)

    Y. N. Pavlov

    2015-01-01

    Full Text Available The work concerns a problem of increasing identification accuracy of linear dynamic systems on the basis of experimental data obtained by applying test signals to the system.The work is aimed at considering a possibility to use the experimentally obtained hodograph counting to determine parameters of this system in a specific context of the linear dynamic system of the second order.An offer was to use a method of harmonious linearization and a described cut method.The type of frequency transfer function of the identified system was assumed as known.It was supposed that when obtaining the frequency characteristics of a real system there are disturbances interfering with experiment as a result of which points of experimentally received hodograph are random displaced.An identification problem solution was searched in a class of the hodograph set by the system model, which had the same type of frequency transfer function, as the type of frequency transfer function of the identified system.The unknown coefficients of frequency transfer function of the system model were searched through minimizing a proximity criterion (measure of the experimentally received hodograph of the system and of the system model hodograph over the entire aggregate of points. One of the authors described this criterion in the earlier publication.The solution to a problem of nonlinear dynamic system identification by the frequency hodograph was reduced to the solution of the system of equations of the rather unknown linear parameters of frequency transfer function of the system model.The program to simulate a process of the pseudo-experimental data, containing random errors, and determine parameters of this system is developed for a dynamic system of the second order.A conducted computing experiment is conducted to estimate an error at which the offered algorithm defines the values of parameters of this system.

  3. Developing a dynamic virtual stimulation protocol to induce linear egomotion during orthostatic posture control test

    Directory of Open Access Journals (Sweden)

    Paulo José Guimarães Da-Silva

    Full Text Available Abstract Introduction In this work, the effect of a dynamic visual stimulation (DS protocol was used to induce egomotion, the center of pressure (COP displacement response. Methods DS was developed concerning the scenario structure (chessboard-pattern floor and furniture and luminance. To move the scenario in a discrete forward (or backward direction, the furniture is expanded (or reduced and the black and white background is reversed during floor translation while the luminance is increased (or reduced by steps of 2 cd/m2. This protocol was evaluated using COP signals from 29 healthy volunteers: standing on a force platform observing the virtual scene (1.72 × 1.16 m projected 1 m ahead (visual incidence angle: θl = 81.4° and θv = 60.2°, which moves with constant velocity (2 m/s during 250 ms. A set of 100 DS was applied in random order, interspersed by a 10 s of static scene. Results The Tukey post-hoc test (p < 0.001 indicated egomotion in the same direction of DS. COP displacement increased over stimulation (8.4 ± 1.7 to 22.6 ±5.3 mm, as well as time to recover stability (4.1 ± 0.4 to 7.2 ± 0.6 s. The peak of egomotion during DSF occurred 200 ms after DSB (Wilcoxon, p = 0.002. Conclusion The dynamic configuration of this protocol establishes virtual flow effects of linear egomotion dependent on the direction of the dynamic visual stimulation. This finding indicates the potential application of the proposed virtual dynamic stimulation protocol to investigate the cortical visual evoked response in postural control studies.

  4. Using PHREEQC for modelling and simulation of dynamic leaching tests and scenarios.

    Science.gov (United States)

    Tiruta-Barna, L

    2008-09-15

    This paper presents an extension of the application field of PHREEQC geochemical software for modelling the dynamic leaching tests (and scenarios) by taking into account the leachant compartment as complex reactive/transport system and the coupling of many reactive compartments linked by substance fluxes. This study focuses on the specific case of dynamic leaching of monolithic porous materials (particularly the case of continuous monolithic leaching test, CMLT) where reaction/diffusion occurs in the porous matrix and where the leachant is a complex reactor in which chemistry coupled with inter-phase mass transfer and convection processes take place. It is demonstrated here that the modelling of open reactors (convection) is possible with PHREEQC by using RATES and KINETICS keyword data blocks. The PHREEQC model was validated by results comparison with analytical solutions of the system equations. Coupling a diffusion compartment with an open reactor (complex boundary conditions for the diffusion equation) requires the introduction of a stagnant cell on the first grid cell of the diffusion compartment in TRANSPORT data block and the use of MIX function for model the monolith/leachant interface transfer. The proposed model was validated by comparison with numerical solutions obtained with MATLAB and by a numerical sensibility study. Finally, the model equations are given for a complex dynamic leaching process of a porous monolith involving beside reaction/diffusion in the monolith, reactions, interface mass transfers, gas absorption and convection in the leachant. Examples of PHREEQC modelling are presented: (1) the case of continuous leaching of a cement based material using carbonated water and (2) a field scale water storage pool constructed with a solidified/stabilised material. The comparison with the experimental leaching data shows the simulation results are very satisfying.

  5. Experiments in support of the Gas Dynamic Trap based facility for plasma–material interaction testing

    Energy Technology Data Exchange (ETDEWEB)

    Soldatkina, E.I., E-mail: E.I.Soldatkina@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, Lavrentieva Prospect 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090 (Russian Federation); Arakcheev, A.S.; Bagryansky, P.A. [Budker Institute of Nuclear Physics SB RAS, Lavrentieva Prospect 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090 (Russian Federation)

    2013-11-15

    Highlights: • Measurement of plasma heat flux in the mirror of a GDT device had been conducted. • The power density up to 0.25 GW m{sup −2} was experimentally obtained. • Steady state operation has not been achieved due to short NBI pulse. • The possibility of creating the PMI setup based on GDT had been discussed. -- Abstract: The power density along the field lines in the scrape-off layer plasma in machines of the class of ITER, Wendelstein 7-X, NSTX-U is in the range of few hundreds megawatt per square meter. It is crucial for the future of tokamaks and stellarators to develop the plasma science and component technology to handle such high plasma heat fluxes. It would be valuable to produce parallel plasma heat fluxes at these power densities, impinging on test components at very shallow angles, as planned in tokamaks. The primary objective of this work is the direct measurement of plasma heat fluxes in the mirror throat of a Gas Dynamic Trap device. Options to develop a facility for plasma–material interaction testing based on the Gas Dynamic Trap are discussed.

  6. Testing efficacy of monthly forecast application in agrometeorology: Winter wheat phenology dynamic

    Science.gov (United States)

    Lalic, B.; Jankovic, D.; Dekic, Lj; Eitzinger, J.; Firanj Sremac, A.

    2017-02-01

    Use of monthly weather forecast as input meteorological data for agrometeorological forecasting, crop modelling and plant protection can foster promising applications in agricultural production. Operational use of monthly or seasonal weather forecast can help farmers to optimize field operations (fertilizing, irrigation) and protection measures against plant diseases and pests by taking full advantage of monthly forecast information in predicting plant development, pest and disease risks and yield potentials few weeks in advance. It can help producers to obtain stable or higher yield with the same inputs and to minimise losses caused by weather. In Central and South-Eastern Europe ongoing climate change lead to shifts of crops phenology dynamics (i.e. in Serbia 4-8 weeks earlier in 2016 than in previous years) and brings this subject in the front of agronomy science and practice. Objective of this study is to test efficacy of monthly forecast in predicting phenology dynamics of different winter wheat varieties, using phenological model developed by Forecasting and Warning Service of Serbia in plant protection. For that purpose, historical monthly forecast for four months (March 1, 2005 - June 30, 2005) was assimilated from ECMWF MARS archive for 50 ensemble members and control run. Impact of different agroecological conditions is tested by using observed and forecasted data for two locations - Rimski Sancevi (Serbia) and Groß-Enzersdorf (Austria).

  7. Closed Cycle Engine Program Used in Solar Dynamic Power Testing Effort

    Science.gov (United States)

    Ensworth, Clint B., III; McKissock, David B.

    1998-01-01

    NASA Lewis Research Center is testing the world's first integrated solar dynamic power system in a simulated space environment. This system converts solar thermal energy into electrical energy by using a closed-cycle gas turbine and alternator. A NASA-developed analysis code called the Closed Cycle Engine Program (CCEP) has been used for both pretest predictions and post-test analysis of system performance. The solar dynamic power system has a reflective concentrator that focuses solar thermal energy into a cavity receiver. The receiver is a heat exchanger that transfers the thermal power to a working fluid, an inert gas mixture of helium and xenon. The receiver also uses a phase-change material to store the thermal energy so that the system can continue producing power when there is no solar input power, such as when an Earth-orbiting satellite is in eclipse. The system uses a recuperated closed Brayton cycle to convert thermal power to mechanical power. Heated gas from the receiver expands through a turbine that turns an alternator and a compressor. The system also includes a gas cooler and a radiator, which reject waste cycle heat, and a recuperator, a gas-to-gas heat exchanger that improves cycle efficiency by recovering thermal energy.

  8. Experimental and Numerical Evaluation of Rock Dynamic Test with Split-Hopkinson Pressure Bar

    Directory of Open Access Journals (Sweden)

    Kang Peng

    2017-01-01

    Full Text Available Feasibility of rock dynamic properties by split-Hopkinson pressure bar (SHPB was experimentally and numerically evaluated with ANSYS/LS-DYNA. The effects of different diameters, different loading rates, and different propagation distances on wave dispersion of input bars in SHPB with rectangle and half-sine wave loadings were analyzed. The results show that the dispersion effect on the diameter of input bar, loading rate, and propagation distance under half-sine waveform loading is ignorable compared with the rectangle wave loading. Moreover, the degrees of stress uniformity under rectangle and half-sine input wave loadings are compared in SHPB tests, and the time required for stress uniformity is calculated under different above-mentioned loadings. It is confirmed that the stress uniformity can be realized more easily using the half-sine pulse loading compared to the rectangle pulse loading, and this has significant advantages in the dynamic test of rock-like materials. Finally, the Holmquist-Johnson-Concrete constitutive model is introduced to simulate the failure mechanism and failure and fragmentation characteristics of rock under different strain rates. And the numerical results agree with that obtained from the experiment, which confirms the effectiveness of the model and the method.

  9. EDISON-WMW: Exact Dynamic Programing Solution of the Wilcoxon–Mann–Whitney Test

    Directory of Open Access Journals (Sweden)

    Alexander Marx

    2016-02-01

    Full Text Available In many research disciplines, hypothesis tests are applied to evaluate whether findings are statistically significant or could be explained by chance. The Wilcoxon–Mann–Whitney (WMW test is among the most popular hypothesis tests in medicine and life science to analyze if two groups of samples are equally distributed. This nonparametric statistical homogeneity test is commonly applied in molecular diagnosis. Generally, the solution of the WMW test takes a high combinatorial effort for large sample cohorts containing a significant number of ties. Hence, P value is frequently approximated by a normal distribution. We developed EDISON-WMW, a new approach to calculate the exact permutation of the two-tailed unpaired WMW test without any corrections required and allowing for ties. The method relies on dynamic programing to solve the combinatorial problem of the WMW test efficiently. Beyond a straightforward implementation of the algorithm, we presented different optimization strategies and developed a parallel solution. Using our program, the exact P value for large cohorts containing more than 1000 samples with ties can be calculated within minutes. We demonstrate the performance of this novel approach on randomly-generated data, benchmark it against 13 other commonly-applied approaches and moreover evaluate molecular biomarkers for lung carcinoma and chronic obstructive pulmonary disease (COPD. We found that approximated P values were generally higher than the exact solution provided by EDISON-WMW. Importantly, the algorithm can also be applied to high-throughput omics datasets, where hundreds or thousands of features are included. To provide easy access to the multi-threaded version of EDISON-WMW, a web-based solution of our algorithm is freely available at http://www.ccb.uni-saarland.de/software/wtest/.

  10. Impact dynamics research facility for full-scale aircraft crash testing

    Science.gov (United States)

    Vaughan, V. L. J.; Alfaro-Bou, E.

    1976-01-01

    An impact dynamics research facility (IDRF) was developed to crash test full-scale general aviation aircraft under free-flight test conditions. The aircraft are crashed into the impact surface as free bodies; a pendulum swing method is used to obtain desired flight paths and velocities. Flight paths up to -60 deg and aircraft velocities along the flight paths up to about 27.0 m/s can be obtained with a combination of swing-cable lengths and release heights made available by a large gantry. Seven twin engine, 2721-kg aircraft were successfully crash tested at the facility, and all systems functioned properly. Acquisition of data from signals generated by accelerometers on board the aircraft and from external and onboard camera coverage was successful in spite of the amount of damage which occurred during each crash. Test parameters at the IDRF are controllable with flight path angles accurate within 8 percent, aircraft velocity accurate within 6 percent, pitch angles accurate to 4.25 deg, and roll and yaw angles acceptable under wind velocities up to 4.5 m/s.

  11. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    Science.gov (United States)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The

  12. Applications of Dynamic Clamp to Cardiac Arrhythmia Research: Role in Drug Target Discovery and Safety Pharmacology Testing.

    Science.gov (United States)

    Ortega, Francis A; Grandi, Eleonora; Krogh-Madsen, Trine; Christini, David J

    2017-01-01

    Dynamic clamp, a hybrid-computational-experimental technique that has been used to elucidate ionic mechanisms underlying cardiac electrophysiology, is emerging as a promising tool in the discovery of potential anti-arrhythmic targets and in pharmacological safety testing. Through the injection of computationally simulated conductances into isolated cardiomyocytes in a real-time continuous loop, dynamic clamp has greatly expanded the capabilities of patch clamp outside traditional static voltage and current protocols. Recent applications include fine manipulation of injected artificial conductances to identify promising drug targets in the prevention of arrhythmia and the direct testing of model-based hypotheses. Furthermore, dynamic clamp has been used to enhance existing experimental models by addressing their intrinsic limitations, which increased predictive power in identifying pro-arrhythmic pharmacological compounds. Here, we review the recent advances of the dynamic clamp technique in cardiac electrophysiology with a focus on its future role in the development of safety testing and discovery of anti-arrhythmic drugs.

  13. Comparison of three different concepts of high dynamic range and dependability optimised current measurement digitisers for beam loss systems

    CERN Document Server

    Viganò, W; Effinger, E; Venturini, G G; Zamantzas, C

    2012-01-01

    Three Different Concepts of High Dynamic Range and Dependability Optimised Current Measurement Digitisers for Beam Loss Systems will be compared on this paper. The first concept is based on Current to Frequency Conversion, enhanced with an ADC for extending the dynamic range and decreasing the response time. A summary of 3 years’ worth of operational experience with such a system for LHC beam loss monitoring will be given. The second principle is based on an Adaptive Current to Frequency Converter implemented in an ASIC. The basic parameters of the circuit are discussed and compared with measurements. Several measures are taken to harden both circuits against single event effects and to make them tolerant for operation in radioactive environments. The third circuit is based on a Fully Differential Integrator for enhanced dynamic range, where laboratory and test installation measurements will be presented. All circuits are designed to avoid any dead time in the acquisition and have reliability and fail safe...

  14. Dynamic behaviour of raft and pile foundations tests and computational models. Pt. 1

    International Nuclear Information System (INIS)

    Betbeder, J.; Garnier, J.C.; Gauvain, J.; Jeandidier, C.

    1981-01-01

    Pile foundations are commonly used for many types of buildings where the bearing capacity of soil is poor. For nuclear power plants buildings, however, there seems to be a fairly general reluctancy to accept design on piles, as it is considered difficult to demonstrate the safety of these foundations with respect to earthquakes, due to the relative lack of validation of the currently available aseismic design methods. Being conscious that pile foundations might be worth considering for future nuclear sites in France and that the reliability of design methods should be backed by experimental data, ELECTRICITE DE FRANCE decided in 1978 to undertake a series of tests, aimed at assessing the validity of computational models for seismic behaviour of pile foundations and trying to define better models if necessary. These tests on reduced scale structure, including various types of raft and pile foundations and different kinds of dynamic excitation (harmonic, earthquake simulation, impulsive release of a static force) have been made at the NICE airport site. The present paper deals with the general description of the tests and the first part of interpretation work, limited to in-structure harmonic excitation and earthquake simulation tests analyzed by simple spring -dashpot analytical models. The two following papers (K5-6 and K5-7) are devoted to specialized topics in relation with the interpretation of tests, i-e ground motions analysis for earthquake simulation and research work on a new computational model. Although preliminary conclusions can be drawn from the results obtained so far, further work will be necessary to reach a conclusive assessment on this difficult subject. (orig.)

  15. Computational Fluid Dynamics Study on the Effects of RATO Timing on the Scale Model Acoustic Test

    Science.gov (United States)

    Nielsen, Tanner; Williams, B.; West, Jeff

    2015-01-01

    The Scale Model Acoustic Test (SMAT) is a 5% scale test of the Space Launch System (SLS), which is currently being designed at Marshall Space Flight Center (MSFC). The purpose of this test is to characterize and understand a variety of acoustic phenomena that occur during the early portions of lift off, one being the overpressure environment that develops shortly after booster ignition. The SLS lift off configuration consists of four RS-25 liquid thrusters on the core stage, with two solid boosters connected to each side. Past experience with scale model testing at MSFC (in ER42), has shown that there is a delay in the ignition of the Rocket Assisted Take Off (RATO) motor, which is used as the 5% scale analog of the solid boosters, after the signal to ignite is given. This delay can range from 0 to 16.5ms. While this small of a delay maybe insignificant in the case of the full scale SLS, it can significantly alter the data obtained during the SMAT due to the much smaller geometry. The speed of sound of the air and combustion gas constituents is not scaled, and therefore the SMAT pressure waves propagate at approximately the same speed as occurs during full scale. However, the SMAT geometry is much smaller allowing the pressure waves to move down the exhaust duct, through the trench, and impact the vehicle model much faster than occurs at full scale. To better understand the effect of the RATO timing simultaneity on the SMAT IOP test data, a computational fluid dynamics (CFD) analysis was performed using the Loci/CHEM CFD software program. Five different timing offsets, based on RATO ignition delay statistics, were simulated. A variety of results and comparisons will be given, assessing the overall effect of RATO timing simultaneity on the SMAT overpressure environment.

  16. Real-time numerical evaluation of dynamic tests with sudden closing of valves in piping systems

    International Nuclear Information System (INIS)

    Geidel, W.; Leimbach, K.R.

    1979-01-01

    The sudden closing of a valve in a piping system causes a build-up of pressure which, in turn, causes severe vibrations of the structural system. The licensing procedure calls for on-site tests to determine the dynamic effects of such closing of valves, and to check the stresses and displacements against the allowable ones. The measurements include time histories of displacements, accelerations and internal pressure. The computer program KWUROHR for the static and dynamic analysis of piping systems has been used by KWU and several subcontractors during the past four vears. This program has been extended by adding a subroutine package which computes time histories of displacements, accelerations and stresses resulting from the input of measured time histories of internal pressures at selected locations. The computer algorithm establishes the topological connectivity between the internal pressure measuring locations, to set up a logic for linear pressure interpolation between these points and pressure steps at reducers and valves. A minimum number of input points is required to give realistic results. (orig.)

  17. Testing and modeling the dynamic response of foam materials for blast protection

    Science.gov (United States)

    Fitek, John H.

    The pressure wave released from an explosion can cause injury to the lungs. A personal armor system concept for blast lung injury protection consists of a polymer foam layer behind a rigid armor plate to be worn over the chest. This research develops a method for testing and modeling the dynamic response of foam materials to be used for down-selection of materials for this application. Constitutive equations for foam materials are incorporated into a lumped parameter model of the combined armor plate and foam system. Impact testing and shock tube testing are used to measure the foam model parameters and validate the model response to a pressure wave load. The plate and foam armor model is then coupled to a model of the human thorax. With a blast pressure wave input, the armor model is evaluated based on how it affects the injury-causing mechanism of chest wall motion. Results show that to reduce chest wall motion, the foam must compress at a relatively constant stress level, which requires a sufficient foam thickness.

  18. Developing a press for static and dynamic testing of orthopedic devices and biological tissue

    Directory of Open Access Journals (Sweden)

    Arlex Leyton Virgen

    2008-09-01

    Full Text Available This paper describes designing and constructing a test machine having a 1,800 N capacity and maximum 3 Hz frequency which will be used in static and dynamic testing of biological tissues and orthopedic devices such as external fixers. It consists of an oc-tagonal base with 500 mm distance between faces and a crosshead which slides between two columns (useful 350 mm opening thus allowing changing the height (maximum 600 mm according to the size of the specimen to be tested. A ball screw actuator is mounted over the crosshead which transforms a servomotor’s rotating movement into a lineal movement (maximum 150 mm stroke. First validations indicated that the machine performed within the design parameters. This project shows that the techno-logy required for supporting research is possible in developing countries thereby avoiding dependence on foreign companies for supporting, maintaining and updating equipment. Some conditions were also produced for the evolution of mechanical engi-neering in Colombia.

  19. Dynamic Finite Element Predictions for Mars Sample Return Cellular Impact Test #4

    Science.gov (United States)

    Fasanella, Edwin L.; Billings, Marcus D.

    2001-01-01

    The nonlinear, transient dynamic finite element code, MSC.Dytran, was used to simulate an impact test of an energy absorbing Earth Entry Vehicle (EEV) that will impact without a parachute. EEVOs are designed to return materials from asteroids, comets, or planets for laboratory analysis on Earth. The EEV concept uses an energy absorbing cellular structure designed to contain and limit the acceleration of space exploration samples during Earth impact. The spherical shaped cellular structure is composed of solid hexagonal and pentagonal foam-filled cells with hybrid graphite-epoxy/Kevlar cell walls. Space samples fit inside a smaller sphere at the center of the EEVOs cellular structure. Pre-test analytical predictions were compared with the test results from a bungee accelerator. The model used to represent the foam and the proper failure criteria for the cell walls were critical in predicting the impact loads of the cellular structure. It was determined that a FOAM1 model for the foam and a 20% failure strain criteria for the cell walls gave an accurate prediction of the acceleration pulse for cellular impact.

  20. Dynamic Impact Testing and Model Development in Support of NASA's Advanced Composites Program

    Science.gov (United States)

    Melis, Matthew E.; Pereira, J. Michael; Goldberg, Robert; Rassaian, Mostafa

    2018-01-01

    The purpose of this paper is to provide an executive overview of the HEDI effort for NASA's Advanced Composites Program and establish the foundation for the remaining papers to follow in the 2018 SciTech special session NASA ACC High Energy Dynamic Impact. The paper summarizes the work done for the Advanced Composites Program to advance our understanding of the behavior of composite materials during high energy impact events and to advance the ability of analytical tools to provide predictive simulations. The experimental program carried out at GRC is summarized and a status on the current development state for MAT213 will be provided. Future work will be discussed as the HEDI effort transitions from fundamental analysis and testing to investigating sub-component structural concept response to impact events.