WorldWideScience

Sample records for ducted fan engines

  1. Optimized Matching Lift Unit Transmission Ratio of Engine Driven Ducted Fan

    Directory of Open Access Journals (Sweden)

    Xiao Senlin

    2018-01-01

    Full Text Available As a kind of VTOL technology, ducted fan is not only used by many kinds of aircrafts, but also one of the trends of the future aircraft lift system, and attracts more and more attention. For an engine driven ducted fan lift unit, involving the engine and ducted fan matching problem, the form of transmission and transmission ratio are the key design parameters. In order to design and develop a ducted fan aircraft reasonably, a thrust test platform was set up to connect the engine with the ducted fan through the belt driving. The matching relationship between the engine and the transmission system was experimentally studied and the optimal transmission ratio was determined. The results showed that the optimal transmission ratio for the engine 1 is 2.2:1, and for the engine 2, the optimal transmission ratio should be 2.95:1 based on the current ducted and movable blade aerofoil design. At this time, the lift will exceed 130 kg•f, meeting the aircraft's original design requirements.

  2. Reverse Flow Engine Core Having a Ducted Fan with Integrated Secondary Flow Blades

    Science.gov (United States)

    Kisska, Michael K. (Inventor); Princen, Norman H. (Inventor); Kuehn, Mark S. (Inventor); Cosentino, Gary B. (Inventor)

    2014-01-01

    Secondary air flow is provided for a ducted fan having a reverse flow turbine engine core driving a fan blisk. The fan blisk incorporates a set of thrust fan blades extending from an outer hub and a set of integral secondary flow blades extending intermediate an inner hub and the outer hub. A nacelle provides an outer flow duct for the thrust fan blades and a secondary flow duct carries flow from the integral secondary flow blades as cooling air for components of the reverse flow turbine engine.

  3. An Integrated Heavy Fuel Piston Engine Ducted Fan Propulsion Unit for Personal Air Vehicles, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed PAVE propulsion system technology demonstration combines an innovative high-speed aero-diesel engine with a novel ducted fan assembly resulting in a low...

  4. An Integrated Heavy Fuel Piston Engine Ducted Fan Propulsion Unit for Personal Air Vehicles, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed PAVE propulsion system technology demonstration combines an innovative high-speed aero-diesel engine with a novel ducted fan assembly resulting in a low...

  5. Turbofan gas turbine engine with variable fan outlet guide vanes

    Science.gov (United States)

    Wood, Peter John (Inventor); LaChapelle, Donald George (Inventor); Grant, Carl (Inventor); Zenon, Ruby Lasandra (Inventor); Mielke, Mark Joseph (Inventor)

    2010-01-01

    A turbofan gas turbine engine includes a forward fan section with a row of fan rotor blades, a core engine, and a fan bypass duct downstream of the forward fan section and radially outwardly of the core engine. The forward fan section has only a single stage of variable fan guide vanes which are variable fan outlet guide vanes downstream of the forward fan rotor blades. An exemplary embodiment of the engine includes an afterburner downstream of the fan bypass duct between the core engine and an exhaust nozzle. The variable fan outlet guide vanes are operable to pivot from a nominal OGV position at take-off to an open OGV position at a high flight Mach Number which may be in a range of between about 2.5-4+. Struts extend radially across a radially inwardly curved portion of a flowpath of the engine between the forward fan section and the core engine.

  6. Prediction of fan assisted flow in a duct/pipe network

    International Nuclear Information System (INIS)

    Quraishi, M.S.

    1996-01-01

    The commonly used fan+duct model is usually based on a table generated by matching the fan and system characteristic curves with the applied pressure drop across the fan+duct/pipe network and using linear or polynomial interpolation for intermediate values. However, this empirical approach can only handle a single system configuration for each table. If this approach is replaced by an algebraic formulation a general and flexible model can be developed. The algebraic model will be able to account for failure of resistances in the duct/pipe system as well as the failure of duct/pipe at an intermediate location. This paper presents the development of an algebraic model for fan+duct/pipe systems. (author)

  7. Acoustic Power Transmission Through a Ducted Fan

    Science.gov (United States)

    Envia, Ed

    2016-01-01

    For high-speed ducted fans, when the rotor flowfield is shock-free, the main contribution to the inlet radiated acoustic power comes from the portion of the rotor stator interaction sound field that is transmitted upstream through the rotor. As such, inclusion of the acoustic transmission is an essential ingredient in the prediction of the fan inlet noise when the fan tip relative speed is subsonic. This paper describes a linearized Euler based approach to computing the acoustic transmission of fan tones through the rotor. The approach is embodied in a code called LINFLUX was applied to a candidate subsonic fan called the Advanced Ducted Propulsor (ADP). The results from this study suggest that it is possible to make such prediction with sufficient fidelity to provide an indication of the acoustic transmission trends with the fan tip speed.

  8. Locating and Quantifying Broadband Fan Sources Using In-Duct Microphones

    Science.gov (United States)

    Dougherty, Robert P.; Walker, Bruce E.; Sutliff, Daniel L.

    2010-01-01

    In-duct beamforming techniques have been developed for locating broadband noise sources on a low-speed fan and quantifying the acoustic power in the inlet and aft fan ducts. The NASA Glenn Research Center's Advanced Noise Control Fan was used as a test bed. Several of the blades were modified to provide a broadband source to evaluate the efficacy of the in-duct beamforming technique. Phased arrays consisting of rings and line arrays of microphones were employed. For the imaging, the data were mathematically resampled in the frame of reference of the rotating fan. For both the imaging and power measurement steps, array steering vectors were computed using annular duct modal expansions, selected subsets of the cross spectral matrix elements were used, and the DAMAS and CLEAN-SC deconvolution algorithms were applied.

  9. CFD Study of an Annular-Ducted Fan Lift System for VTOL Aircraft

    Directory of Open Access Journals (Sweden)

    Yun Jiang

    2015-09-01

    Full Text Available The present study aimed at assessing a novel annular-ducted fan lift system for VTOL aircraft through computational fluid dynamics (CFD simulations. The power and lift efficiency of the lift fan system in hover mode, the lift and drag in transition mode, the drag and flight speed of the aircraft in cruise mode and the pneumatic coupling of the tip turbine and jet exhaust were studied. The results show that the annular-ducted fan lift system can have higher lift efficiency compared to the rotor of the Apache helicopter; the smooth transition from vertical takeoff to cruise flight needs some extra forward thrust to overcome a low peak of drag; the aircraft with the lift fan system enclosed during cruise flight theoretically may fly faster than helicopters and tiltrotors based on aerodynamic drag prediction, due to the elimination of rotor drag and compressibility effects on the rotor blade tips; and pneumatic coupling of the tip turbine and jet exhaust of a 300 m/s velocity can provide enough moment to spin the lift fan. The CFD results provide insight for future experimental study of the annular-ducted lift fan VTOL aircraft.

  10. Low-frequency noise reduction of fans using the acoustically treated duct; Kyuon duct ni yoru fan soon no teishuhaiki teigen

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, K; Fujii, S [University of Osaka Prefecture, Osaka (Japan). Faculty of Engineering; Shirasaya, H [Kawasaki Heavy Industries, Ltd., Tokyo (Japan)

    1994-12-25

    Reducing noise in a low frequency region of 1 kHz or less has become an important problem as a result of emergence of an ultra-high bypass engine in aircraft engines. Therefore, an attempt was made of experimenting and analyzing noise absorption characteristics in low-frequency noises. In the experiment, a low-frequency flow with an air volume of about 3 m{sup 3}/minute was made at a stable operating point of a fan device consisting of moving blades and static blades, with a sound absorbing duct disposed in the forward section. The duct is a 500-mm long steel box with an oblong cross section, in which the top and the bottom parts can move vertically, and a variable air layer was formed between a sound absorbing material (a sheet material made of microfine spherical resin powders solidified to a thickness of 6 mm) and a rigid wall made of iron plate. Noise waves and sound absorption amount were measured on different air layer thicknesses, and analyzed theoretically. As a result, such findings were obtained as: the sound absorption amount is affected by the main stream direction mode of sound pressures in cavity; valleys are formed where the sound absorption amount decreases remarkably in a specific cycle; and peaks are built where the sound absorption amount increases in other regions. 7 refs., 12 figs.

  11. Active Control of Fan Noise: Feasibility Study. Volume 6; Theoretical Analysis for Coupling of Active Noise Control Actuator Ring Sources to an Annular Duct with Flow

    Science.gov (United States)

    Kraft, R. E.

    1996-01-01

    The objective of this effort is to develop an analytical model for the coupling of active noise control (ANC) piston-type actuators that are mounted flush to the inner and outer walls of an annular duct to the modes in the duct generated by the actuator motion. The analysis will be used to couple the ANC actuators to the modal analysis propagation computer program for the annular duct, to predict the effects of active suppression of fan-generated engine noise sources. This combined program will then be available to assist in the design or evaluation of ANC systems in fan engine annular exhaust ducts. An analysis has been developed to predict the modes generated in an annular duct due to the coupling of flush-mounted ring actuators on the inner and outer walls of the duct. The analysis has been combined with a previous analysis for the coupling of modes to a cylindrical duct in a FORTRAN computer program to perform the computations. The method includes the effects of uniform mean flow in the duct. The program can be used for design or evaluation purposes for active noise control hardware for turbofan engines. Predictions for some sample cases modeled after the geometry of the NASA Lewis ANC Fan indicate very efficient coupling in both the inlet and exhaust ducts for the m = 6 spinning mode at frequencies where only a single radial mode is cut-on. Radial mode content in higher order cut-off modes at the source plane and the required actuator displacement amplitude to achieve 110 dB SPL levels in the desired mode were predicted. Equivalent cases with and without flow were examined for the cylindrical and annular geometry, and little difference was found for a duct flow Mach number of 0.1. The actuator ring coupling program will be adapted as a subroutine to the cylindrical duct modal analysis and the exhaust duct modal analysis. This will allow the fan source to be defined in terms of characteristic modes at the fan source plane and predict the propagation to the

  12. Low Cost/Low Noise Variable Pitch Ducted Fan, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ACI proposes a design for a Propulsor (Low Cost/Low Noise Variable Pitch Ducted Fan) that has wide application in all sectors of Aviation. Propulsor hardware of this...

  13. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  14. A Near-Hover Adaptive Attitude Control Strategy of a Ducted Fan Micro Aerial Vehicle with Actuator Dynamics

    Directory of Open Access Journals (Sweden)

    Shouzhao Sheng

    2015-09-01

    Full Text Available The aerodynamic parameters of ducted fan micro aerial vehicles (MAVs are difficult and expensive to precisely measure and are, therefore, not available in most cases. Furthermore, the actuator dynamics with risks of potentially destabilizing the overall system are important but often neglected consideration factors in the control system design of ducted fan MAVs. This paper presents a near-hover adaptive attitude control strategy of a prototype ducted fan MAV with actuator dynamics and without any prior information about the behavior of the MAV. The proposed strategy consists of an online parameter estimation algorithm and an adaptive gain scheduling algorithm, with the former accommodating parametric uncertainties, and the latter approximately eliminating the coupling among axes and guaranteeing the control quality of the MAV. The effectiveness of the proposed strategy is verified numerically and experimentally.

  15. Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

    Science.gov (United States)

    Eichenberg, Dennis J.; Emerson, Dawn C.; Gallo, Christopher A.; Thompson, William K.

    2011-01-01

    This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

  16. Validation of the Predicted Circumferential and Radial Mode Sound Power Levels in the Inlet and Exhaust Ducts of a Fan Ingesting Distorted Inflow

    Science.gov (United States)

    Koch, L. Danielle

    2012-01-01

    Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.

  17. Fuselage boundary-layer refraction of fan tones radiated from an installed turbofan aero-engine.

    Science.gov (United States)

    Gaffney, James; McAlpine, Alan; Kingan, Michael J

    2017-03-01

    A distributed source model to predict fan tone noise levels of an installed turbofan aero-engine is extended to include the refraction effects caused by the fuselage boundary layer. The model is a simple representation of an installed turbofan, where fan tones are represented in terms of spinning modes radiated from a semi-infinite circular duct, and the aircraft's fuselage is represented by an infinitely long, rigid cylinder. The distributed source is a disk, formed by integrating infinitesimal volume sources located on the intake duct termination. The cylinder is located adjacent to the disk. There is uniform axial flow, aligned with the axis of the cylinder, everywhere except close to the cylinder where there is a constant thickness boundary layer. The aim is to predict the near-field acoustic pressure, and in particular, to predict the pressure on the cylindrical fuselage which is relevant to assess cabin noise. Thus no far-field approximations are included in the modelling. The effect of the boundary layer is quantified by calculating the area-averaged mean square pressure over the cylinder's surface with and without the boundary layer included in the prediction model. The sound propagation through the boundary layer is calculated by solving the Pridmore-Brown equation. Results from the theoretical method show that the boundary layer has a significant effect on the predicted sound pressure levels on the cylindrical fuselage, owing to sound radiation of fan tones from an installed turbofan aero-engine.

  18. Jet Engine Fan Response to Inlet Distortions Generated by Ingesting Boundary Layer Flow

    Science.gov (United States)

    Giuliani, James Edward

    Future civil transport designs may incorporate engines integrated into the body of the aircraft to take advantage of efficiency increases due to weight and drag reduction. Additional increases in engine efficiency are predicted if the inlets ingest the lower momentum boundary layer flow that develops along the surface of the aircraft. Previous studies have shown, however, that the efficiency benefits of Boundary Layer Ingesting (BLI) inlets are very sensitive to the magnitude of fan and duct losses, and blade structural response to the non-uniform flow field that results from a BLI inlet has not been studied in-depth. This project represents an effort to extend the modeling capabilities of TURBO, an existing rotating turbomachinery unsteady analysis code, to include the ability to solve the external and internal flow fields of a BLI inlet. The TURBO code has been a successful tool in evaluating fan response to flow distortions for traditional engine/inlet integrations. Extending TURBO to simulate the external and inlet flow field upstream of the fan will allow accurate pressure distortions that result from BLI inlet configurations to be computed and used to analyze fan aerodynamics and structural response. To validate the modifications for the BLI inlet flow field, an experimental NASA project to study flush-mounted S-duct inlets with large amounts of boundary layer ingestion was modeled. Results for the flow upstream and in the inlet are presented and compared to experimental data for several high Reynolds number flows to validate the modifications to the solver. Once the inlet modifications were validated, a hypothetical compressor fan was connected to the inlet, matching the inlet operating conditions so that the effect on the distortion could be evaluated. Although the total pressure distortion upstream of the fan was symmetrical for this geometry, the pressure rise generated by the fan blades was not, because of the velocity non-uniformity of the distortion

  19. Effect of discharge duct geometry on centrifugal fan performance and noise emission

    Science.gov (United States)

    Nelson, David A.; Butrymowicz, William; Thomas, Christopher

    2005-09-01

    Non-ideal inlet and discharge duct geometries can cause significant changes to both the aerodynamic performance (``fan curve'') and specific sound power emission of a fan. A proper understanding of actual installed performance, as well as a good estimate of the system backpressure curve, is critical to achieving flow and acoustic goals as well as other criteria such as power consumption, mass and volume. To this end a battery of ISO 10302 tests was performed on a blower assembly which supports the Advanced Animal Habitat, being developed by ORBITEC for deployment on the International Space Station. The blower assembly consists of (4) identical centrifugal fans that, amongst themselves and across two prototypes, incorporated several discharge geometries. The inlet geometries were identical in all cases. Thus by comparing the dimensionless pressure-flow and noise emission characteristics across the cases, significant insight into the nature and potential magnitude of these effects is gained.

  20. Computational Aerodynamic Simulations of an 840 ft/sec Tip Speed Advanced Ducted Propulsor Fan System Model for Acoustic Methods Assessment and Development

    Science.gov (United States)

    Tweedt, Daniel L.

    2014-01-01

    Computational Aerodynamic simulations of an 840 ft/sec tip speed, Advanced Ducted Propulsor fan system were performed at five different operating points on the fan operating line, in order to provide detailed internal flow field information for use with fan acoustic prediction methods presently being developed, assessed and validated. The fan system is a sub-scale, lownoise research fan/nacelle model that has undergone extensive experimental testing in the 9- by 15- foot Low Speed Wind Tunnel at the NASA Glenn Research Center, resulting in quality, detailed aerodynamic and acoustic measurement data. Details of the fan geometry, the computational fluid dynamics methods, the computational grids, and various computational parameters relevant to the numerical simulations are discussed. Flow field results for three of the five operating conditions simulated are presented in order to provide a representative look at the computed solutions. Each of the five fan aerodynamic simulations involved the entire fan system, excluding a long core duct section downstream of the core inlet guide vane. As a result, only fan rotational speed and system bypass ratio, set by specifying static pressure downstream of the core inlet guide vane row, were adjusted in order to set the fan operating point, leading to operating points that lie on a fan operating line and making mass flow rate a fully dependent parameter. The resulting mass flow rates are in good agreement with measurement values. The computed blade row flow fields for all five fan operating points are, in general, aerodynamically healthy. Rotor blade and fan exit guide vane flow characteristics are good, including incidence and deviation angles, chordwise static pressure distributions, blade surface boundary layers, secondary flow structures, and blade wakes. Examination of the computed flow fields reveals no excessive boundary layer separations or related secondary-flow problems. A few spanwise comparisons between

  1. Active Control of Fan Noise: Feasibility Study. Volume 3; Active Fan Noise Cancellation in the NASA Lewis Active Noise Control Fan Facility

    Science.gov (United States)

    Pla, Frederic G.; Hu, Ziqiang; Sutliff, Daniel L.

    1996-01-01

    This report describes the Active Noise Cancellation (ANC) System designed by General Electric and tested in the NASA Lewis Research Center's (LERC) 48 inch Active Noise Control Fan (ANCF). The goal of this study is to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for global active noise cancellation of fan tones. The GE ANC system is based on a modal control approach. A known acoustic mode propagating in the fan duct is canceled using an array of flush-mounted compact sound sources. The canceling modal signal is generated by a modal controller. Inputs to the controller are signals from a shaft encoder and from a microphone array which senses the residual acoustic mode in the duct. The key results are that the (6,0) was completely eliminated at the 920 Hz design frequency and substantially reduced elsewhere. The total tone power was reduced 6.8 dB (out of a possible 9.8 dB). Farfield reductions of 15 dB (SPL) were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB PWL decrease. The results indicate that global attenuation of PWL at the target frequency was obtained in the aft quadrant using an ANC actuator and sensor system totally contained within the duct. The quality of the results depended on precise mode generation. High spillover into spurious modes generated by the ANC actuator array caused less than optimum levels of PWL reduction. The variation in spillover is believed to be due to calibration procedure, but must be confirmed in subsequent tests.

  2. Robust D-Stability Controller Design for a Ducted Fan Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Xiao-lu Ren

    2014-01-01

    Full Text Available This paper deals with the aerodynamic modeling of a small ducted fan UAV and the problem of attitude stabilization when the parameter of the vehicle is varied. The main aerodynamic model of the hovering flight UAV is first presented. Then, an attitude control is designed from a linearization of the dynamic model around the hovering flight, which is based on the H∞ output feedback control theory with D-stability. Simulation results show that such method has good robustness to the attitude system. They can meet the requirements of attitude control and verify further the feasibility of such a control strategy.

  3. Numerical Simulation of Boundary Layer Ingesting (BLI) Inlet-Fan Interaction

    Science.gov (United States)

    Giuliani, James; Chen, Jen-Ping; Beach, Timothy; Bakhle, Milind

    2014-01-01

    Future civil transport designs may incorporate engine inlets integrated into the body of the aircraft to take advantage of efficiency increases due to weight and drag reduction. Additional increases in engine efficiency are predicted if the inlet ingests the lower momentum boundary layer flow. Previous studies have shown, however, that efficiency benefits of Boundary Layer Ingesting (BLI) ingestion are very sensitive to the magnitude of fan and duct losses, and blade structural response to the non-uniform flow field that results from a BLI inlet has not been studied in-depth. This paper presents an effort to extend the modeling capabilities of an existing rotating turbomachinery unsteady analysis code to include the ability to solve the external and internal flow fields of a BLI inlet. The TURBO code has been a successful tool in evaluating fan response to flow distortions for traditional engine/inlet integrations, such as the development of rotating stall and inlet distortion through compressor stages. This paper describes the first phase of an effort to extend the TURBO model to calculate the external and inlet flowfield upstream of fan so that accurate pressure distortions that result from BLI configurations can be computed and used to analyze fan aerodynamics and structural response. To validate the TURBO program modifications for the BLI flowfield, experimental test data obtained by NASA for a flushmounted S-duct with large amounts of boundary layer ingestion was modeled. Results for the flow upstream and in the inlet are presented and compared to experimental data for several high Reynolds number flows to validate the modifications to the solver. Quantitative data is presented that indicates good predictive capability of the model in the upstream flow. A representative fan is attached to the inlet and results are presented for the coupled inlet/fan model. The impact on the total pressure distortion at the AIP after the fan is attached is examined.

  4. The Canadian residential duct and chimney survey

    Energy Technology Data Exchange (ETDEWEB)

    Fugler, D.

    2003-12-01

    A study was conducted in 1989 to better understand the thermal performance of ducts and chimneys in houses. The objective was to address the problems associated with insufficient airflow and backdrafting of combustion gases resulting from malfunctioning fans, furnaces and fireplaces. The Duct Test Rig was used to measure and recorded airflows and heat losses in a variety of ducts and chimneys in a representative mix of houses in Vancouver, Kelowna, Winnipeg, Calgary, Toronto, London, Montreal, Quebec City, Halifax, Fredericton and Ottawa. Bath, kitchen, clothes dryer and central vacuum exhaust fans were tested to determine how performance is affected by fan age, accumulations of dust, grease, bugs and installation methods. Results indicate that there is no statistical difference between axial or centrifugal fans. The greatest problem appeared to be with low flows, high leakage rates, and poor conditions of bathroom fans. Many kitchen fans were found to be blocked at the inlet by cooking grease. The exhaust flows depended greatly on the condition of the backdraft damper. Dryer exhaust airflow was typically less than the 75 L/s specified by manufacturers, but even old dryers performed relatively well. All types of chimneys were tested for different positive hood pressures, airflow lost through leakage, and thermal characteristics. Airflow was found to vary depending on the type and area of the flue and the presence of a cap. For heating systems, the low duct efficiency was due mostly to duct leakage, radiation losses and restrictive ducts and registers. The findings of this testing program are still valid today. 3 tabs.

  5. Analysis of Dual Rotating Rake Data from the NASA Glenn Advanced Noise Control Fan Duct with Artificial Sources

    Science.gov (United States)

    Dahl, Milo D.; Sutliff, Daniel L.

    2014-01-01

    The Rotating Rake mode measurement system was designed to measure acoustic duct modes generated by a fan stage. Initially, the mode amplitudes and phases were quantified from a single rake measurement at one axial location. To directly measure the modes propagating in both directions within a duct, a second rake was mounted to the rotating system with an offset in both the axial and the azimuthal directions. The rotating rake data analysis technique was then extended to include the data measured by the second rake. The analysis resulted in a set of circumferential mode levels at each of the two rake microphone locations. Radial basis functions were then least-squares fit to this data to obtain the radial mode amplitudes for the modes propagating in both directions within the duct. Validation experiments have been conducted using artificial acoustic sources. Results are shown for the measurement of the standing waves in the duct from sound generated by one and two acoustic sources that are separated into the component modes propagating in both directions within the duct. Measured reflection coefficients from the open end of the duct are compared to analytical predictions.

  6. Gas Turbine Engine Having Fan Rotor Driven by Turbine Exhaust and with a Bypass

    Science.gov (United States)

    Suciu, Gabriel L. (Inventor); Chandler, Jesse M. (Inventor)

    2016-01-01

    A gas turbine engine has a core engine incorporating a core engine turbine. A fan rotor is driven by a fan rotor turbine. The fan rotor turbine is in the path of gases downstream from the core engine turbine. A bypass door is moveable from a closed position at which the gases from the core engine turbine pass over the fan rotor turbine, and moveable to a bypass position at which the gases are directed away from the fan rotor turbine. An aircraft is also disclosed.

  7. Variable cycle engine

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, A.P.; Sprunger, E.V.

    1980-09-16

    A variable cycle turboshaft engine includes a remote fan system and respective high and low pressure systems for selectively driving the fan system in such a manner as to provide VTOL takeoff capability and minimum specific fuel consumption (SFC) at cruise and loiter conditions. For takeoff the fan system is primarily driven by the relatively large low pressure system whose combustor receives the motive fluid from a core bypass duct and, for cruise and loiter conditions, the fan system is driven by both a relatively small high pressure core and the low pressure system with its combustor inoperative. A mixer is disposed downstream of the high pressure system for mixing the relatively cold air from the bypass duct and the relatively hot air from the core prior to its flow to the low pressure turbine.

  8. Recent progress in fan and compressor for aeroengine. Koku engine yo fan asshukuki no saikin no gijutsu shinpo

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y [National Aerospace Lab., Chofu, Tokyo (Japan)

    1994-03-10

    As the main components of the aeroengine, the fan and compressor reach to extremely high level stage technologically. Also at present when about 50 years passed after the jet engine was applied in practice, however, an effort for a modification is being continued, and furthermore even in the 1990s, the engines that adopted the new technologies are in succession being put in practical application. New engines in the 1990s are being applied in practice by adopting the study results on fan and compressor from the 1970s to the 1980s. Because, which way the future fan and compressor of the aircraft will go to has a relation with an aircraft trend from now on, and even in the 2000s the high subsonic speed aircrafts will be a center of the private air planes. The engine of high subsonic speed aircraft in the next generation will become an ultrahigh bypass ratio engine, the thrust efficiency is raised and noise is lowered, by lowering a fan pressure ratio and by increasing an air flow quantity compared with the current high bypass ratio turbofan engine. 16 figs.

  9. Active sources in the cutoff of centrifugal fans to reduce the blade tones at higher-order duct mode frequencies

    Science.gov (United States)

    Neise, W.; Koopmann, G. H.

    1991-01-01

    A previously developed (e.g., Neise and Koopmann, 1984; Koopmann et al., 1988) active noise control technique in which the unwanted acoustic signals from centrifugal fans are suppressed by placing two externally driven sources near the cutoff of the casing was applied to the frequency region where not only plane sound waves are propagational in the fan ducts but also higher-order acoustic modes. Using a specially designed fan noise testing facility, the performance of two fans (280-mm impeller diam and 508 mm diam) was monitored with static pressure taps mounted peripherally around the inlet nozzle. Experimental results show that the aerodynamically generated source pressure field around the cutoff is too complex to be successfully counterimaged by only two active sources introduced in this region. It is suggested that, for an efficient application of this noise control technique in the higher-order mode frequency regime, it is neccessary to use an active source involving larger number of individually driven loudspeakers.

  10. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  11. First Test of Fan Active Noise Control (ANC) Completed

    Science.gov (United States)

    2005-01-01

    With the advent of ultrahigh-bypass engines, the space available for passive acoustic treatment is becoming more limited, whereas noise regulations are becoming more stringent. Active noise control (ANC) holds promise as a solution to this problem. It uses secondary (added) noise sources to reduce or eliminate the offending noise radiation. The first active noise control test on the low-speed fan test bed was a General Electric Company system designed to control either the exhaust or inlet fan tone. This system consists of a "ring source," an induct array of error microphones, and a control computer. Fan tone noise propagates in a duct in the form of spinning waves. These waves are detected by the microphone array, and the computer identifies their spinning structure. The computer then controls the "ring source" to generate waves that have the same spinning structure and amplitude, but 180 out of phase with the fan noise. This computer generated tone cancels the fan tone before it radiates from the duct and is heard in the far field. The "ring source" used in these tests is a cylindrical array of 16 flat-plate acoustic radiators that are driven by thin piezoceramic sheets bonded to their back surfaces. The resulting source can produce spinning waves up to mode 7 at levels high enough to cancel the fan tone. The control software is flexible enough to work on spinning mode orders from -6 to 6. In this test, the fan was configured to produce a tone of order 6. The complete modal (spinning and radial) structure of the tones was measured with two builtin sets of rotating microphone rakes. These rakes provide a measurement of the system performance independent from the control system error microphones. In addition, the far-field noise was measured with a semicircular array of 28 microphones. This test represents the first in a series of tests that demonstrate different active noise control concepts, each on a progressively more complicated modal structure. The tests are

  12. Indirect Adaptive Attitude Control for a Ducted Fan Vertical Takeoff and Landing Microaerial Vehicle

    Directory of Open Access Journals (Sweden)

    Shouzhao Sheng

    2015-01-01

    Full Text Available The present paper addresses an attitude tracking control problem of a ducted fan microaerial vehicle. The proposed indirect adaptive controller can greatly reduce tracking error in the initial stage of the adaptive learning process by using an error compensation strategy and can achieve good capability to eliminate the adverse effect of measurement noises on the convergence of adjustable parameters. Moreover, the learning rate adaptation strategy is proposed to further minimize the adverse effect of large learning rates on the convergence of adjustable parameters. The experimental tests have illustrated the effectiveness of the proposed adaptive controller.

  13. On the design and structural analysis of jet engine fan blade structures

    Science.gov (United States)

    Amoo, Leye M.

    2013-07-01

    Progress in the design and structural analysis of commercial jet engine fan blades is reviewed and presented. This article is motivated by the key role fan blades play in the performance of advanced gas turbine jet engines. The fundamentals of the associated physics are emphasized. Recent developments and advancements have led to an increase and improvement in fan blade structural durability, stability and reliability. This article is intended as a high level review of the fan blade environment and current state of structural design to aid further research in developing new and innovative fan blade technologies.

  14. Broadband Liner Optimization for the Source Diagnostic Test Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.

    2012-01-01

    The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more appealing. This paper describes a broadband acoustic liner optimization study for the scale model Source Diagnostic Test fan. Specifically, in-duct attenuation predictions with a statistical fan source model are used to obtain optimum impedance spectra over a number of flow conditions for three liner locations in the bypass duct. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Typical tonal liner designs targeting single frequencies at one operating condition are first produced to provide baseline performance information. These are followed by multiple broadband design approaches culminating in a broadband liner targeting the full range of frequencies and operating conditions. The broadband liner is found to satisfy the optimum impedance objectives much better than the tonal liner designs. In addition, the broadband liner is found to provide better attenuation than the tonal designs over the full range of frequencies and operating conditions considered. Thus, the current study successfully establishes a process for the initial design and evaluation of novel broadband liner concepts for complex engine configurations.

  15. Improved Broadband Liner Optimization Applied to the Advanced Noise Control Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.; Sutliff, Daniel L.; Ayle, Earl; Ichihashi, Fumitaka

    2014-01-01

    The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more desirable. This paper describes improvements to a previously established broadband acoustic liner optimization process using the Advanced Noise Control Fan rig as a demonstrator. Specifically, in-duct attenuation predictions with a statistical source model are used to obtain optimum impedance spectra over the conditions of interest. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Constant-depth, double-degree of freedom and variable-depth, multi-degree of freedom designs are carried through design, fabrication, and testing to validate the efficacy of the design process. Results illustrate the value of the design process in concurrently evaluating the relative costs/benefits of these liner designs. This study also provides an application for demonstrating the integrated use of duct acoustic propagation/radiation and liner modeling tools in the design and evaluation of novel broadband liner concepts for complex engine configurations.

  16. Turbine Engine with Differential Gear Driven Fan and Compressor

    Science.gov (United States)

    Suciu, Gabriel L. (Inventor); Pagluica, Gino J. (Inventor); Duong, Loc Quang (Inventor); Portlock, Lawrence E. (Inventor)

    2013-01-01

    A gas turbine engine provides a differential gear system coupling the turbine to the bypass fan and the compressor. In this manner, the power/speed split between the bypass fan and the compressor can be optimized under all conditions. In the example shown, the turbine drives a sun gear, which drives a planet carrier and a ring gear in a differential manner. One of the planet carrier and the ring gear is coupled to the bypass fan, while the other is coupled to the compressor.

  17. Silent cooling system with a double suction type centrifugal fan with backward blades; Ryosuikomi turbo fan wo mochiita teisoon engine reikyaku system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Funabashi, S. [Hitachi, Ltd., Tokyo (Japan); Nakamura, K. [Hitachi Construction Machinery Co. Ltd., Tokyo (Japan)

    2000-04-25

    We have developed a new cooling system for the engine of construction machinery. This system produces two different air flow routes by a double suction type centrifugal fan with backward blades. We first measured aerodynamic performance and sound level of the double suction type fan, which consists of two single suction type fans of different design, and compared these measurements to those of single suction type fans. Next, we installed the fan in a scale model of the new cooling system. The performance of this double suction type fan was different to that of a single suction type. It is considered that the effect of interaction of the exit flows from the two different fans caused this performance change. The test model installed in an engine compartment showed that this cooling system reduced the area of air inlets and outlets around the engine and did not cause re-circulation of cooling air. (author)

  18. Preliminary Aerodynamic Investigation of Fan Rotor Blade Morphing

    Science.gov (United States)

    Tweedt, Daniel L.

    2012-01-01

    Various new technologies currently under development may enable controlled blade shape variability, or so-called blade morphing, to be practically employed in aircraft engine fans and compressors in the foreseeable future. The current study is a relatively brief, preliminary computational fluid dynamics investigation aimed at partially demonstrating and quantifying the aerodynamic potential of fan rotor blade morphing. The investigation is intended to provide information useful for near-term planning, as well as aerodynamic solution data sets that can be subsequently analyzed using advanced acoustic diagnostic tools, for the purpose of making fan noise comparisons. Two existing fan system models serve as baselines for the investigation: the Advanced Ducted Propulsor fan with a design tip speed of 806 ft/sec and a pressure ratio of 1.294, and the Source Diagnostic Test fan with a design tip speed of 1215 ft/sec and a pressure ratio of 1.470. Both are 22-in. sub-scale, low-noise research fan/nacelle models that have undergone extensive experimental testing in the 9- by 15-foot Low Speed Wind Tunnel at the NASA Glenn Research Center. The study, restricted to fan rotor blade morphing only, involves a fairly simple blade morphing technique. Specifically, spanwise-linear variations in rotor blade-section setting angle are applied to alter the blade shape; that is, the blade is linearly retwisted from hub to tip. Aerodynamic performance comparisons are made between morphed-blade and corresponding baseline configurations on the basis of equal fan system thrust, where rotor rotational speed for the morphed-blade fan is varied to change the thrust level for that configuration. The results of the investigation confirm that rotor blade morphing could be a useful technology, with the potential to enable significant improvements in fan aerodynamic performance. Even though the study is very limited in scope and confined to simple geometric perturbations of two existing fan

  19. Development of Adaptive Acoustic Impedance Control Technologies of Acoustic Duct Liner

    Directory of Open Access Journals (Sweden)

    Hiroshi Kobayashi

    2011-01-01

    Full Text Available This paper describes the development of adaptive acoustic impedance control (AAC technologies to achieve a larger fan noise reduction, by adaptively adjusting reactance and resistance of the acoustic liner impedance. For the actual proof of the AAC technology III performance, the advanced fan noise absorption control duct liner II was made on trial basis, with the simple control system and the plain device. And, then, the duct liner II was examined for the AAC technology I, II, and III models, using the high speed fan test facility. The test results made clear that the duct liner II of the AAC technology III model could achieve the fan noise reduction higher than O.A. SPL 10 dB (A at the maximum fan speed 6000 rpm, containing the reduction of fundamental BPF tone of 18 dB and 2nd BPF tone of 10 dB in response to the fan peed change from 3000 to 6000 rpm.

  20. Modeling of Broadband Liners Applied to the Advanced Noise Control Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.; Sutliff, Daniel L.

    2015-01-01

    The broadband component of fan noise has grown in relevance with an increase in bypass ratio and incorporation of advanced fan designs. Therefore, while the attenuation of fan tones remains a major factor in engine nacelle acoustic liner design, the simultaneous reduction of broadband fan noise levels has received increased interest. As such, a previous investigation focused on improvements to an established broadband acoustic liner optimization process using the Advanced Noise Control Fan (ANCF) rig as a demonstrator. Constant-depth, double-degree of freedom and variable-depth, multi-degree of freedom liner designs were carried through design, fabrication, and testing. This paper addresses a number of areas for further research identified in the initial assessment of the ANCF study. Specifically, incident source specification and uncertainty in some aspects of the predicted liner impedances are addressed. This information is incorporated in updated predictions of the liner performance and comparisons with measurement are greatly improved. Results illustrate the value of the design process in concurrently evaluating the relative costs/benefits of various liner designs. This study also provides further confidence in the integrated use of duct acoustic propagation/radiation and liner modeling tools in the design and evaluation of novel broadband liner concepts for complex engine configurations.

  1. The Application of Advanced Technique of Fan Frame Unit on High Bypass Ratio Aero Engine

    Directory of Open Access Journals (Sweden)

    Hou Peng

    2017-01-01

    Full Text Available High bypass ratio aero-engine was widely used on military and civil aviation domain, as the power of larger aircraft. Fan frame unit was the main bearing frame of high bypass ratio aero-engine, which composed of strut, HUB MID BOX and external bypass parts. Resin/composite was used on external bypass parts(acoustic liner, containment ring, fan outlet guide vane and fan case skin fillets, which not only reduced the weight and manufacturing cost, but also improved the noise absorption, containment and anti-fatigue ability of engine. The design of composite was becoming a key technique for high bypass ratio aero-engine. In special test of the core engine, nitrogen cooling system was designed to cool the cavity of spool. The nitrogen pipeline passed through the inner cavity of fan frame, then inserted into NO. 3 bearing seal, so nitrogen gas was sent into the cavity of core engine spool. On high bypass ratio aero-engine, the external bypass and fan frame inner cavity were the design platform for advanced technique, such as composite and pipeline system, and also provided guarantee for reliable operation of engine.

  2. Impeller Design of a Centrifugal Fan with Blade Optimization

    Directory of Open Access Journals (Sweden)

    Yu-Tai Lee

    2011-01-01

    Full Text Available A method is presented for redesigning a centrifugal impeller and its inlet duct. The double-discharge volute casing is a structural constraint and is maintained for its shape. The redesign effort was geared towards meeting the design volute exit pressure while reducing the power required to operate the fan. Given the high performance of the baseline impeller, the redesign adopted a high-fidelity CFD-based computational approach capable of accounting for all aerodynamic losses. The present effort utilized a numerical optimization with experiential steering techniques to redesign the fan blades, inlet duct, and shroud of the impeller. The resulting flow path modifications not only met the pressure requirement, but also reduced the fan power by 8.8% over the baseline. A refined CFD assessment of the impeller/volute coupling and the gap between the stationary duct and the rotating shroud revealed a reduction in efficiency due to the volute and the gap. The calculations verified that the new impeller matches better with the original volute. Model-fan measured data was used to validate CFD predictions and impeller design goals. The CFD results further demonstrate a Reynolds-number effect between the model- and full-scale fans.

  3. Coupled Analysis of an Inlet and Fan for a Quiet Supersonic Jet

    Science.gov (United States)

    Chima, Rodrick V.; Conners, Timothy R.; Wayman, Thomas R.

    2010-01-01

    A computational analysis of a Gulfstream isentropic external compression supersonic inlet coupled to a Rolls-Royce fan has been completed. The inlet was designed for a small, low sonic boom supersonic vehicle with a design cruise condition of M = 1.6 at 45,000 ft. The inlet design included an annular bypass duct that routed flow subsonically around an engine-mounted gearbox and diverted flow with high shock losses away from the fan tip. Two Reynolds-averaged Navier-Stokes codes were used for the analysis: an axisymmetric code called AVCS for the inlet and a three dimensional (3-D) code called SWIFT for the fan. The codes were coupled at a mixing plane boundary using a separate code for data exchange. The codes were used to determine the performance of the inlet/fan system at the design point and to predict the performance and operability of the system over the flight profile. At the design point the core inlet had a recovery of 96 percent, and the fan operated near its peak efficiency and pressure ratio. A large hub radial distortion generated in the inlet was not eliminated by the fan and could pose a challenge for subsequent booster stages. The system operated stably at all points along the flight profile. Reduced stall margin was seen at low altitude and Mach number where flow separated on the interior lips of the cowl and bypass ducts. The coupled analysis gave consistent solutions at all points on the flight profile that would be difficult or impossible to predict by analysis of isolated components.

  4. Coupled Analysis of an Inlet and Fan for a Quiet Supersonic Aircraft

    Science.gov (United States)

    Chima, Rodrick V.; Conners, Timothy R.; Wayman, Thomas R.

    2009-01-01

    A computational analysis of a Gulfstream isentropic external compression supersonic inlet coupled to a Rolls-Royce fan was completed. The inlet was designed for a small, low sonic boom supersonic vehicle with a design cruise condition of M = 1.6 at 45,000 feet. The inlet design included an annular bypass duct that routed flow subsonically around an engine-mounted gearbox and diverted flow with high shock losses away from the fan tip. Two Reynolds-averaged Navier-Stokes codes were used for the analysis: an axisymmetric code called AVCS for the inlet and a 3-D code called SWIFT for the fan. The codes were coupled at a mixing plane boundary using a separate code for data exchange. The codes were used to determine the performance of the inlet/fan system at the design point and to predict the performance and operability of the system over the flight profile. At the design point the core inlet had a recovery of 96 percent, and the fan operated near its peak efficiency and pressure ratio. A large hub radial distortion generated in the inlet was not eliminated by the fan and could pose a challenge for subsequent booster stages. The system operated stably at all points along the flight profile. Reduced stall margin was seen at low altitude and Mach number where flow separated on the interior lips of the cowl and bypass ducts. The coupled analysis gave consistent solutions at all points on the flight profile that would be difficult or impossible to predict by analysis of isolated components.

  5. Advanced Low-Noise Research Fan Stage Design

    Science.gov (United States)

    Neubert, Robert; Bock, Larry; Malmborg, Eric; Owen-Peer, William

    1997-01-01

    This report describes the design of the Advanced Low-Noise Research Fan stage. The fan is a variable pitch design, which is designed at the cruise pitch condition. Relative to the cruise setting, the blade is closed at takeoff and opened for reverse thrust operation. The fan stage is a split flow design with fan exit guide vanes (FEGVs) and core stators. The fan stage design is combined with a nacelle and engine core duct to form a powered fan/nacelle subscale model. This model is intended for use in combined aerodynamic, acoustic, and structural testing in a wind tunnel. The fan has an outer diameter of 22 in. and a hub-to-tip of 0.426 in., which allows the use of existing NASA fan and cowl force balance and rig drive systems. The design parameters were selected to permit valid acoustic and aerodynamic comparisons with the Pratt & Whitney (P&W) 17- and 22-in. rigs previously tested under NASA contract. The fan stage design is described in detail. The results of the design axisymmetric and Navier-Stokes aerodynamic analysis are presented at the critical design conditions. The structural analysis of the fan rotor and attachment is included. The blade and attachment are predicted to have adequate low-cycle fatigue life and an acceptable operating range without resonant stress or flutter. The stage was acoustically designed with airfoil counts in the FEGV and core stator to minimize noise. A fan/FEGV tone analysis developed separately under NASA contract was used to determine the optimum airfoil counts. The fan stage was matched to the existing nacelle, designed under the previous P&W low-noise contract, to form a fan/nacelle model for wind tunnel testing. It is an axisymmetric nacelle for convenience in testing and analysis. Previous testing confirmed that the nacelle performed as required at various aircraft operating conditions.

  6. Low Noise Research Fan Stage Design

    Science.gov (United States)

    Hobbs, David E.; Neubert, Robert J.; Malmborg, Eric W.; Philbrick, Daniel H.; Spear, David A.

    1995-01-01

    This report describes the design of a Low Noise ADP Research Fan stage. The fan is a variable pitch design which is designed at the cruise pitch condition. Relative to the cruise setting, the blade is closed at takeoff and opened for reverse thrust operation. The fan stage is a split flow design with fan exit guide vanes and core stators. This fan stage design was combined with a nacelle and engine core duct to form a powered fan/nacelle, subscale model. This model is intended for use in aerodynamic performance, acoustic and structural testing in a wind tunnel. The model has a 22-inch outer fan diameter and a hub-to-top ratio of 0.426 which permits the use of existing NASA fan and cowl force balance designs and rig drive system. The design parameters were selected to permit valid acoustic and aerodynamic comparisons with the PW 17-inch rig previously tested under NASA contract. The fan stage design is described in detail. The results of the design axisymmetric analysis at aerodynamic design condition are included. The structural analysis of the fan rotor and attachment is described including the material selections and stress analysis. The blade and attachment are predicted to have adequate low cycle fatigue life, and an acceptable operating range without resonant stress or flutter. The stage was acoustically designed with airfoil counts in the fan exit guide vane and core stator to minimize noise. A fan-FEGV tone analysis developed separately under NASA contract was used to determine these airfoil counts. The fan stage design was matched to a nacelle design to form a fan/nacelle model for wind tunnel testing. The nacelle design was developed under a separate NASA contract. The nacelle was designed with an axisymmetric inlet, cowl and nozzle for convenience in testing and fabrication. Aerodynamic analysis of the nacelle confirmed the required performance at various aircraft operating conditions.

  7. Passive Techniques for Fan Noise Reduction in New Turbofan Engines: Review

    Directory of Open Access Journals (Sweden)

    M.Gorj-Bandpy

    2013-03-01

    Full Text Available Among the various environmental concerns, the aircraft noise item has been constantly growing in importance over the past years. Measures for its reduction at the source as well its mitigation around airports must take into account aspects of medicine and technical design as well as legal and land use planning aspects. Fan noise is one of the principal noise sources in turbofan aero-engines. In this paper a review of the main technologies employed for the reduction of fan noise turbofan engines is presented.

  8. Stability and Control Characteristics of a Model of an Aerial Vehicle Supported by Four Ducted Fans

    Science.gov (United States)

    Parlett, Lysle P.

    1961-01-01

    The stability and control characteristics of a simple, lightly loaded model approximately one-third the size of a full-scale vehicle have been investigated by a series of free-flight tests. The model is representative of a type of vertically rising aircraft which would utilize four ducted fans as its sole source of lift and propulsion. The ducts were arranged in a rectangular pattern and were fixed to the airframe so that their axes of revolution were vertical for hovering flight. Control moments were provided by remotely controlled compressed-air jets at the sides and ends of the model. In hovering, the model in its original configuration exhibited divergent oscillations about both the roll and pitch axes. Because these oscillations were of a rather short period., the model was very difficult to control by the use of remote controls only. The model could be completely stabilized by the addition of a sufficient amount of artificial damping. The pitching oscillation was made easier to control by increasing the distance between the forward and rearward pairs of ducts. In forward flight, with the model in its original configuration, the top speed was limited by the development of an uncontrollable pitch-up. Large forward tilt angles were required for trim at the highest speeds attained. With the model rotated so that the shorter axis became the longitudinal axis, the pitch trim problem was found to be less than with the longer axis as the longitudinal axis. The installation of a system of vanes in the slipstream of the forward ducts reduced the tilt angle but increased the power required.

  9. Volcanic ash ingestion by a large gas turbine aeroengine: fan-particle interaction

    Science.gov (United States)

    Vogel, Andreas; Clarkson, Rory; Durant, Adam; Cassiani, Massimo; Stohl, Andreas

    2016-04-01

    code (CD Adapco STAR-CCM+ with an implicit coupled flow and energy algorithm) for compressible high-speed flows including a Lagrangian particle-tracking model for the simulation of the particle behaviour for typical atmospheric particle size ranges between 1 and 100 μm. The simulations indicate that the predominant proportion of larger particles (> 20 microns) tend to be transported into the bypass duct of the engine (by the centrifugal effect of the fan), whereas the smaller particles follow the fluid flow streamlines and are distributed homogenously in the engine (bypass ducts and core region). This result is significant as it indicates that the absolute ash mass that causes issues for aeroengine operation is a fraction of the ambient (observed or forecast) ash quantity.

  10. Effect of sail on augmenting attitude stability of hovering VTOL vehicle supported by one-ducted-fan. Ductedter dot fan shiji VTOL ki no hover shisei anteisei eno ho no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Ando, S.; Kato, M. (Nagoya University, Nagoya (Japan). Faculty of Engineering)

    1991-07-05

    An analytical investigation was given on augmenting attitude stability of a VTOL airplane supported by one-ducted-fan, at hovering, by means of installing a sail having air resistance on a place higher than the vehicle center-of-gravity. Since the problem becomes nonlinear, the time-marching technique was used. The sail on which the emphasis was placed had an area of as less than several times as much of the duct sectional area, and a height of as less than several times as much of the duct diameter. The stabilization effect is expressed as {Delta}h = center of gravity height region providing the stability/duct diameter. Without a sail, {Delta}h was several percent, but with a sail, the value increased to about ten times as much. This increase in {Delta}h was remarkable in the direction that elevate the position of the center of gravity. More stability is obtained by increasing the sail height than by increasing the area. Substitutes to a sail, working on the same principle, could be a gas-bag and wind mill. A gas-bag, which can change its volume readily, will be able to vary the sail area easily. A wind mill could make the weight lighter than a sail, and has a possibility of varying the resistance through changing its blade pitch angle. 2 refs., 2 figs., 1 tab.

  11. Tune-Up Your Fan Systems for Improved Performance

    Energy Technology Data Exchange (ETDEWEB)

    2018-04-03

    Fans are used extensively in commercial buildings and represent approximately 6% of total energy consumed by commercial buildings. The U.S. Department of Energy (DOE) estimates that fans in commercial buildings consume 158 billion kWh of electricity annually. Maintaining fan systems in proper condition provides energy savings and ensures a comfortable and healthy environment. While many fan systems have significant energy savings opportunities available through improvements in fan selection, system design, and operational practices, it is not always apparent when a fan system needs maintenance or what opportunities are available for improvements. This resource is designed for facility managers and maintenance staff to provide easy-to-implement actionable guidance on fan efficiency measures for existing ducted air systems.

  12. Variable Cycle Intake for Reverse Core Engine

    Science.gov (United States)

    Suciu, Gabriel L (Inventor); Chandler, Jesse M (Inventor); Staubach, Joseph B (Inventor)

    2016-01-01

    A gas generator for a reverse core engine propulsion system has a variable cycle intake for the gas generator, which variable cycle intake includes a duct system. The duct system is configured for being selectively disposed in a first position and a second position, wherein free stream air is fed to the gas generator when in the first position, and fan stream air is fed to the gas generator when in the second position.

  13. Lightweight Exhaust Manifold and Exhaust Pipe Ducting for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    An improved exhaust system for an internal combustion gasoline-and/or diesel-fueled engine includes an engine exhaust manifold which has been fabricated from carbon- carbon composite materials in operative association with an exhaust pipe ducting which has been fabricated from carbon-carbon composite materials. When compared to conventional steel. cast iron. or ceramic-lined iron paris. the use of carbon-carbon composite exhaust-gas manifolds and exhaust pipe ducting reduces the overall weight of the engine. which allows for improved acceleration and fuel efficiency: permits operation at higher temperatures without a loss of strength: reduces the "through-the wall" heat loss, which increases engine cycle and turbocharger efficiency and ensures faster "light-off" of catalytic converters: and, with an optional thermal reactor, reduces emission of major pollutants, i.e. hydrocarbons and carbon monoxide.

  14. A supersonic fan equipped variable cycle engine for a Mach 2.7 supersonic transport

    Science.gov (United States)

    Tavares, T. S.

    1985-01-01

    The concept of a variable cycle turbofan engine with an axially supersonic fan stage as powerplant for a Mach 2.7 supersonic transport was evaluated. Quantitative cycle analysis was used to assess the effects of the fan inlet and blading efficiencies on engine performance. Thrust levels predicted by cycle analysis are shown to match the thrust requirements of a representative aircraft. Fan inlet geometry is discussed and it is shown that a fixed geometry conical spike will provide sufficient airflow throughout the operating regime. The supersonic fan considered consists of a single stage comprising a rotor and stator. The concept is similar in principle to a supersonic compressor, but differs by having a stator which removes swirl from the flow without producing a net rise in static pressure. Operating conditions peculiar to the axially supersonic fan are discussed. Geometry of rotor and stator cascades are presented which utilize a supersonic vortex flow distribution. Results of a 2-D CFD flow analysis of these cascades are presented. A simple estimate of passage losses was made using empirical methods.

  15. Designing on-Board Data Handling for EDF (Electric Ducted Fan) Rocket

    Science.gov (United States)

    Mulyana, A.; Faiz, L. A. A.

    2018-02-01

    The EDF (Electric Ducted Fan) rocket to launch requires a system of monitoring, tracking and controlling to allow the rocket to glide properly. One of the important components in the rocket is OBDH (On-Board Data Handling) which serves as a medium to perform commands and data processing. However, TTC (Telemetry, Tracking, and Command) are required to communicate between GCS (Ground Control Station) and OBDH on EDF rockets. So the design control system of EDF rockets and GCS for telemetry and telecommand needs to be made. In the design of integrated OBDH controller uses a lot of electronics modules, to know the behavior of rocket used IMU sensor (Inertial Measurement Unit) in which consist of 3-axis gyroscope sensor and Accelerometer 3-axis. To do tracking using GPS, compass sensor as a determinant of the direction of the rocket as well as a reference point on the z-axis of gyroscope sensor processing and used barometer sensors to measure the height of the rocket at the time of glide. The data can be known in real-time by sending data through radio modules at 2.4 GHz frequency using XBee-Pro S2B to GCS. By using windows filter, noises can be reduced, and it used to guarantee monitoring and controlling system can work properly.

  16. Flow Simulation of Supersonic Inlet with Bypass Annular Duct

    Science.gov (United States)

    Kim, HyoungJin; Kumano, Takayasu; Liou, Meng-Sing; Povinelli, Louis A.; Conners, Timothy R.

    2011-01-01

    A relaxed isentropic compression supersonic inlet is a new concept that produces smaller cowl drag than a conventional inlet, but incurs lower total pressure recovery and increased flow distortion in the (radially) outer flowpath. A supersonic inlet comprising a bypass annulus to the relaxed isentropic compression inlet dumps out airflow of low quality through the bypass duct. A reliable computational fluid dynamics solution can provide considerable useful information to ascertain quantitatively relative merits of the concept, and further provide a basis for optimizing the design. For a fast and reliable performance evaluation of the inlet performance, an equivalent axisymmetric model whose area changes accounts for geometric and physical (blockage) effects resulting from the original complex three-dimensional configuration is proposed. In addition, full three-dimensional calculations are conducted for studying flow phenomena and verifying the validity of the equivalent model. The inlet-engine coupling is carried out by embedding numerical propulsion system simulation engine data into the flow solver for interactive boundary conditions at the engine fan face and exhaust plane. It was found that the blockage resulting from complex three-dimensional geometries in the bypass duct causes significant degradation of inlet performance by pushing the terminal normal shock upstream.

  17. Pratt & Whitney Advanced Ducted Propulsor (ADP) Engine Test in 40x80ft w.t.: Engineers Peter

    Science.gov (United States)

    1993-01-01

    Pratt & Whitney Advanced Ducted Propulsor (ADP) Engine Test in 40x80ft w.t.: Engineers Peter Zell (left) and Dr Clifton Horne (right) are shown preparing a laser light sheet for a flow visualization test. Shown standing in the nacelle of the ADP is John Girvin, senior test engineer for Pratt & Whitney.

  18. Procedure for Balancing an Air Distribution System with Decentralised Fans

    DEFF Research Database (Denmark)

    Gunner, Amalie; Hultmark, Göran; Vorre, Anders

    2015-01-01

    flawed. This paper presents a new procedure for balancing of CAV systems in combination with decentralised fans. The new system was based on replacing the balancing dampers with decentralised fans. By replacing the balancing dampers with decentralised fans, airflows can be balanced by adjusting the speed...... of the fans. In conventional air distribution systems the fan provides the necessary pressure to overcome the resistance in the branch with the highest pressure resistance. This gives an unnecessary overpressure in the remaining branches that does not provide any useful purpose. In order to decrease the fan...... pressure requirements the fan was dimensioned for the branch with the least pressure resistance. The decentralised fans then provided sufficient pressure to overcome the exact resistance in the corresponding branch. The results show that by using decentralised fans in duct systems instead of dampers...

  19. Optimisation of efficiency of axial fans

    NARCIS (Netherlands)

    Kruyt, Nicolaas P.; Pennings, P.C.; Faasen, R.

    2014-01-01

    A three-stage research project has been executed to develop ducted axial-fans with increased efficiency. In the first stage a design method has been developed in which various conflicting design criteria can be incorporated. Based on this design method, an optimised design has been determined

  20. Quiet Clean Short-haul Experimental Engine (QCSEE): The aerodynamic and mechanical design of the QCSEE under-the-wing fan

    Science.gov (United States)

    1977-01-01

    The design, fabrication, and testing of two experimental high bypass geared turbofan engines and propulsion systems for short haul passenger aircraft are described. The aerodynamic and mechanical design of a variable pitch 1.34 pressure ratio fan for the under the wing (UTW) engine are included. The UTW fan was designed to permit rotation of the 18 composite fan blades into the reverse thrust mode of operation through both flat pitch and stall pitch directions.

  1. Quiet Clean Short-haul Experimental Engine (QCSEE). The aerodynamic and mechanical design of the QCSEE over-the-wing fan

    Science.gov (United States)

    1976-01-01

    The aerodynamic and mechanical design of a fixed-pitch 1.36 pressure ratio fan for the over-the-wing (OTW) engine is presented. The fan has 28 blades. Aerodynamically, the fan blades were designed for a composite blade, but titanium blades were used in the experimental fan as a cost savings measure.

  2. Temperature control of an automotive engine cooling system utilizing a magneto-rheological fan clutch

    International Nuclear Information System (INIS)

    Kim, Eun-Seok; Choi, Seung-Bok; Park, Young-Gee; Lee, Soojin

    2010-01-01

    In this note, the temperature control of an automotive engine cooling system is undertaken using a magneto-rheological (MR) fluid-based fan clutch (MR fan clutch in short). In order to achieve this goal, an appropriate size of controllable fan clutch using an MR fluid is firstly devised by considering the design parameters of a conventional fan clutch to reflect the practical application. Then, the principal design parameters of the MR fan clutch such as the length of the disc are optimally determined through finite element analysis. The drum-type MR fan clutch is manufactured and its time response to input current is experimentally evaluated. A robust sliding mode controller is then formulated by treating the time constant of the fan clutch system as an uncertain parameter. After identifying the relationship between angular velocity of the MR fan clutch and the temperature of the cooling system, the sliding mode controller is experimentally realized for the cooling system. It has been clearly demonstrated that the proposed sliding mode controller follows well the desired temperature with a small regulating error. It is expected from this feasibility work that the proposed control system associated with an MR fan clutch can be effectively utilized for the automotive cooling system to improve the fuel efficiency. (technical note)

  3. Enhanced Fan Noise Modeling for Turbofan Engines

    Science.gov (United States)

    Krejsa, Eugene A.; Stone, James R.

    2014-01-01

    This report describes work by consultants to Diversitech Inc. for the NASA Glenn Research Center (GRC) to revise the fan noise prediction procedure based on fan noise data obtained in the 9- by 15 Foot Low-Speed Wind Tunnel at GRC. The purpose of this task is to begin development of an enhanced, analytical, more physics-based, fan noise prediction method applicable to commercial turbofan propulsion systems. The method is to be suitable for programming into a computational model for eventual incorporation into NASA's current aircraft system noise prediction computer codes. The scope of this task is in alignment with the mission of the Propulsion 21 research effort conducted by the coalition of NASA, state government, industry, and academia to develop aeropropulsion technologies. A model for fan noise prediction was developed based on measured noise levels for the R4 rotor with several outlet guide vane variations and three fan exhaust areas. The model predicts the complete fan noise spectrum, including broadband noise, tones, and for supersonic tip speeds, combination tones. Both spectra and directivity are predicted. Good agreement with data was achieved for all fan geometries. Comparisons with data from a second fan, the ADP fan, also showed good agreement.

  4. Unsteady Reynolds-averaged Navier-Stokes simulations of inlet distortion in the fan system of a gas-turbine aero-engine

    Science.gov (United States)

    Spotts, Nathan

    As modern trends in commercial aircraft design move toward high-bypass-ratio fan systems of increasing diameter with shorter, nonaxisymmetric nacelle geometries, inlet distortion is becoming common in all operating regimes. The distortion may induce aerodynamic instabilities within the fan system, leading to catastrophic damage to fan blades, should the surge margin be exceeded. Even in the absence of system instability, the heterogeneity of the flow affects aerodynamic performance significantly. Therefore, an understanding of fan-distortion interaction is critical to aircraft engine system design. This thesis research elucidates the complex fluid dynamics and fan-distortion interaction by means of computational fluid dynamics (CFD) modeling of a complete engine fan system; including rotor, stator, spinner, nacelle and nozzle; under conditions typical of those encountered by commercial aircraft. The CFD simulations, based on a Reynolds-averaged Navier-Stokes (RANS) approach, were unsteady, three-dimensional, and of a full-annulus geometry. A thorough, systematic validation has been performed for configurations from a single passage of a rotor to a full-annulus system by comparing the predicted flow characteristics and aerodynamic performance to those found in literature. The original contributions of this research include the integration of a complete engine fan system, based on the NASA rotor 67 transonic stage and representative of the propulsion systems in commercial aircraft, and a benchmark case for unsteady RANS simulations of distorted flow in such a geometry under realistic operating conditions. This study is unique in that the complex flow dynamics, resulting from fan-distortion interaction, were illustrated in a practical geometry under realistic operating conditions. For example, the compressive stage is shown to influence upstream static pressure distributions and thus suppress separation of flow on the nacelle. Knowledge of such flow physics is

  5. Tone Noise Predictions for a Spacecraft Cabin Ventilation Fan Ingesting Distorted Inflow and the Challenges of Validation

    Science.gov (United States)

    Koch, L. Danielle; Shook, Tony D.; Astler, Douglas T.; Bittinger, Samantha A.

    2012-01-01

    A fan tone noise prediction code has been developed at NASA Glenn Research Center that is capable of estimating duct mode sound power levels for a fan ingesting distorted inflow. This code was used to predict the circumferential and radial mode sound power levels in the inlet and exhaust duct of an axial spacecraft cabin ventilation fan. Noise predictions at fan design rotational speed were generated. Three fan inflow conditions were studied: an undistorted inflow, a circumferentially symmetric inflow distortion pattern (cylindrical rods inserted radially into the flowpath at 15deg, 135deg, and 255deg), and a circumferentially asymmetric inflow distortion pattern (rods located at 15deg, 52deg and 173deg). Noise predictions indicate that tones are produced for the distorted inflow cases that are not present when the fan operates with an undistorted inflow. Experimental data are needed to validate these acoustic predictions, as well as the aerodynamic performance predictions. Given the aerodynamic design of the spacecraft cabin ventilation fan, a mechanical and electrical conceptual design study was conducted. Design features of a fan suitable for obtaining detailed acoustic and aerodynamic measurements needed to validate predictions are discussed.

  6. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 3; Validation and Test Cases

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the third volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User s Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by validation studies that were done on three fan rigs. It concludes with recommended improvements and additional studies for BFaNS.

  7. Design study and performance analysis of a high-speed multistage variable-geometry fan for a variable cycle engine

    Science.gov (United States)

    Sullivan, T. J.; Parker, D. E.

    1979-01-01

    A design technology study was performed to identify a high speed, multistage, variable geometry fan configuration capable of achieving wide flow modulation with near optimum efficiency at the important operating condition. A parametric screening study of the front and rear block fans was conducted in which the influence of major fan design features on weight and efficiency was determined. Key design parameters were varied systematically to determine the fan configuration most suited for a double bypass, variable cycle engine. Two and three stage fans were considered for the front block. A single stage, core driven fan was studied for the rear block. Variable geometry concepts were evaluated to provide near optimum off design performance. A detailed aerodynamic design and a preliminary mechanical design were carried out for the selected fan configuration. Performance predictions were made for the front and rear block fans.

  8. 77 FR 40530 - Energy Conservation Standards for Residential Furnace Fans: Public Meeting and Availability of...

    Science.gov (United States)

    2012-07-10

    ... heating, ventilation, and air-conditioning (HVAC) systems for the purpose of circulating air through duct... INFORMATION: Table of Contents I. Authority II. History of Energy Conservation Standards Rulemaking for... circulating air through duct work, hereinafter referred to as ``residential furnace fans'' or simply ``furnace...

  9. Thermal performance test of hot gas ducts of helium engineering demonstration loop (HENDEL)

    International Nuclear Information System (INIS)

    Hishida, Makoto; Kunitomi, Kazuhiko; Ioka, Ikuo; Umenishi, Koji; Kondo, Yasuo; Tanaka, Toshiyuki; Shimomura, Hiroaki

    1984-01-01

    A hot gas duct provided with internal thermal insulation is supposed to be used for an experimental very high-temperature gas-cooled reactor (VHTR) which has been developed by the Japan Atomic Energy Research Institute (JAERI). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of hot gas duct have been conducted. The present test was to investigate the thermal performance of the hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL) of JAERI. Uniform temperature and heat flux distributions at the surface of the duct were observed, the experimental correlation being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of VHTR hot gas duct was evaluated, and no hot spot was detected. These results would be very valuable for the design and development of VHTR. (author)

  10. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    Science.gov (United States)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  11. Advanced Noise Control Fan: A 20-Year Retrospective

    Science.gov (United States)

    Sutliff, Dan

    2016-01-01

    The ANCF test bed is used for evaluating fan noise reduction concepts, developing noise measurement technologies, and providing a database for Aero-acoustic code development. Rig Capabilities: 4 foot 16 bladed rotor @ 2500 rpm, Auxiliary air delivery system (3 lbm/sec @ 6/12 psi), Variable configuration (rotor pitch angle, stator count/position, duct length), synthetic acoustic noise generation (tone/broadband). Measurement Capabilities: 112 channels dynamic data system, Unique rotating rake mode measuremen, Farfield (variable radius), Duct wall microphones, Stator vane microphones, Two component CTA w/ traversing, ESP for static pressures.

  12. A Mode Propagation Database Suitable for Code Validation Utilizing the NASA Glenn Advanced Noise Control Fan and Artificial Sources

    Science.gov (United States)

    Sutliff, Daniel L.

    2014-01-01

    The NASA Glenn Research Center's Advanced Noise Control Fan (ANCF) was developed in the early 1990s to provide a convenient test bed to measure and understand fan-generated acoustics, duct propagation, and radiation to the farfield. A series of tests were performed primarily for the use of code validation and tool validation. Rotating Rake mode measurements were acquired for parametric sets of: (i) mode blockage, (ii) liner insertion loss, (iii) short ducts, and (iv) mode reflection.

  13. Analysis of impact resistance of composite fan blade. Fukugozai fan blade no taishogekisei no kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Miyachi, T; Okumura, H; Otake, K; Sofue, Y [Japan Society for Aeronautical and Space Sciences, Tokyo (Japan)

    1992-01-05

    Numerical analysis of impact response was carried out when a bird strike was simulated to study the applicability of fiber reinforced composite material to fan blades for turbo-fan engines. The validity of the numerical analysis was verified by comparing the analyzed results with impact tested results of a fan-blade model of Ti-alloy. The impact resistance was studied by applying this method to fan blades of composite materials such as carbon fiber, epoxy resin and carbon-silicate fiber reinforced Ti-alloy. The finite element method was used for the analysis by dividing the model into triangular flat elements. The relation between the impact load, the deformation of blade and the strain, the natural frequency characteristics, the elastic modulus and hetrogeneity of blade were considered to analyze the impact response. The impact load by the strike of 1.5 lbs bird is very severe to the fan blades for turbo-fan engines having the thrust of 5 ton class. 23 refs., 23 figs., 3 tabs.

  14. Full Scale Technology Demonstration of a Modern Counterrotating Unducted Fan Engine Concept. Design Report

    Science.gov (United States)

    1987-01-01

    The Unducted Fan engine (UDF trademark) concept is based on an ungeared, counterrotating, unducted, ultra-high-bypass turbofan configuration. This engine is being developed to provide a high thrust-to-weight ratio power plant with exceptional fuel efficiency for subsonic aircraft application. This report covers the design methodology and details for the major components of this engine. The design intent of the engine is to efficiently produce 25,000 pounds of static thrust while meeting life and stress requirements. The engine is required to operate at Mach numbers of 0.8 or above.

  15. Engineering Task Plan for Hepa Filter Differential Pressure (DP) Fan Interlock Upgrades

    International Nuclear Information System (INIS)

    SIMONS, S.R.

    2000-01-01

    This document provides a plan for installation of Differential Pressure (DP) fan interlocks on the primary ventilation systems in selected Tank Farm facilities. This plan contains the engineering tasks required for installation and is summarized by the Acceptance for Beneficial Use list. Individuals responsible for each task are identified and scheduled accordingly

  16. CFD Study of a New Annular Lift Fan Configuration with High Lift Efficiency

    Directory of Open Access Journals (Sweden)

    Yun Jiang

    2017-03-01

    Full Text Available A new annular lift fan configuration that has very high lift efficiency is explored by using a numerical scheme. The inlet lip radius and diffuser angle are maximized by semicircle duct walls and the location of the lift fan is moved from the throat to the diffuser area to maximize the diffusion effect of the ducted fan. The improved lift fan achieves the figure of merit of 0.772 and the power loading of 9.03 lbs/hp without ground effect, very close to the theoretical limit. Under the ground effect, the figure of merit reaches 0.822 with the power loading of 9.62 lbs/hp. The improved lift efficiency deteriorates the transition characteristics with higher momentum drag and pitching moment. However, with the aid of jet thrusts directly providing part of the lift during transition, the peak of momentum drag and pitching moment can be lowered. A total thrust to weight ratio of 0.7 is enough for all of the requirements in transition and in hover and for the maximum speed of 0.75 Mach in cruise flight.

  17. Study on performance of centripetal fan, 1

    International Nuclear Information System (INIS)

    Ejiri, Eiji; Shirakura, Masaaki; Tagori, Tetsuo; Enomoto, Hisao.

    1984-01-01

    Centripetal fans are radial flow type fans which gather air from outer side into inner side. The construction is simple, and when heat exchangers are arranged around them, cooled air can be discharged upward only by connecting simple ducts, accordingly, centripetal fans are suitable to the ventilating fans for superlarge cooling towers of nuclear power plants. The static pressure rise is obtained only by the diffuser action of impellers, therefore, they are not suitable to pumps and compressors, and their use is limited only to fans. Centrifugal force exerts negative effect on static pressure rise, accordingly, the ratio of internal diameter/external diameter of impellers cannot be made very small. In this study, a small model with impeller diameter of 0.6 m was used, and its overall performance, the performance of moving blades in the range of stable operation, the rotating stall characteristics in the region of low flow rate, and the effect of side wind on the overall performance in outdoor use were examined. By changing the angle of inclination of entrance guide vanes, the range of stable operation was expanded, and the pressure coefficient and efficiency were increased. (Kako, I.)

  18. Design features of fans, blowers, and compressors

    Science.gov (United States)

    Cheremisinoff, N. P.; Cheremisinoff, P. N.

    Fan engineering and compression machines are discussed. Basic aspects of fan performance and design are reviewed, and the design and performance characteristics of radial-flow fans, axial-flow fans, and controllable pitch fans are examined in detail. Air-conditioning systems are discussed, and noise, vibration, and mechanical considerations in fans are extensively examined. The thermodynamic principles governing compression machines are reviewed, and piston compressors, rotary compressors, blowers, and centrifugal compressors are discussed.

  19. Active control of aircraft engine inlet noise using compact sound sources and distributed error sensors

    Science.gov (United States)

    Burdisso, Ricardo (Inventor); Fuller, Chris R. (Inventor); O'Brien, Walter F. (Inventor); Thomas, Russell H. (Inventor); Dungan, Mary E. (Inventor)

    1996-01-01

    An active noise control system using a compact sound source is effective to reduce aircraft engine duct noise. The fan noise from a turbofan engine is controlled using an adaptive filtered-x LMS algorithm. Single multi channel control systems are used to control the fan blade passage frequency (BPF) tone and the BPF tone and the first harmonic of the BPF tone for a plane wave excitation. A multi channel control system is used to control any spinning mode. The multi channel control system to control both fan tones and a high pressure compressor BPF tone simultaneously. In order to make active control of turbofan inlet noise a viable technology, a compact sound source is employed to generate the control field. This control field sound source consists of an array of identical thin, cylindrically curved panels with an inner radius of curvature corresponding to that of the engine inlet. These panels are flush mounted inside the inlet duct and sealed on all edges to prevent leakage around the panel and to minimize the aerodynamic losses created by the addition of the panels. Each panel is driven by one or more piezoelectric force transducers mounted on the surface of the panel. The response of the panel to excitation is maximized when it is driven at its resonance; therefore, the panel is designed such that its fundamental frequency is near the tone to be canceled, typically 2000-4000 Hz.

  20. Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

    Science.gov (United States)

    Koch, L. Danielle; Brown, Clifford A.; Shook, Tony D.; Winkel, James; Kolacz, John S.; Podboy, Devin M.; Loew, Raymond A.; Mirecki, Julius H.

    2012-01-01

    Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in.) in diameter and 0.223 m (9.00 in.) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.709 cu m/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

  1. Numerical Investigation of Effect of Parameters on Hovering Efficiency of an Annular Lift Fan Aircraft

    OpenAIRE

    Yun Jiang; Bo Zhang

    2016-01-01

    The effects of various parameters on the hovering performance of an annular lift fan aircraft are investigated by using numerical scheme. The pitch angle, thickness, aspect ratio (chord length), number of blades, and radius of duct inlet lip are explored to optimize the figure of merit. The annular lift fan is also compared with a conventional circular lift fan of the same features with the same disc loading and similar geometry. The simulation results show that the pitch angle of 27°, the th...

  2. Effectiveness of duct sealing and duct insulation in multi-family buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Karins, N.H.; Tuluca, A.; Modera, M.

    1997-07-01

    This research investigated the cost-effectiveness of sealing and insulating the accessible portions of duct systems exposed to unconditioned areas in multifamily housing. Airflow and temperature measurements were performed in 25 apartments served by 10 systems a 9 multi-family properties. The measurements were performed before and after each retrofit, and included apartment airflow (supply and return), duct system temperatures, system fan flow and duct leakage area. The costs for each retrofit were recorded. The data were analyzed and used to develop a prototypical multifamily house. This prototype was used in energy simulations (DOE-2.1E) and air infiltration simulations (COMIS 2.1). The simulations were performed for two climates: New York City and Albany. In each climate, one simulation was performed assuming the basement was tight, and another assuming the basement was leaky. Simulation results and average retrofit costs were used to calculate cost-effectiveness. The results of the analysis indicate that sealing leaks of the accessible ductwork is cost-effective under all conditions simulated (simple payback was between 3 and 4 years). Insulating the accessible ductwork, however, is only cost-effective for buildings with leaky basement, in both climates (simple paybacks were less than 5 years). The simple payback period for insulating the ducts in buildings with tight basements was greater than 10 years, the threshold of cost-effectiveness for this research. 13 refs., 5 figs., 27 tabs.

  3. Modeling and Control of a Tailsitter with a Ducted Fan

    Science.gov (United States)

    Argyle, Matthew Elliott

    There are two traditional aircraft categories: fixed-wing which have a long endurance and a high cruise airspeed and rotorcraft which can take-off and land vertically. The tailsitter is a type of aircraft that has the strengths of both platforms, with no additional mechanical complexity, because it takes off and lands vertically on its tail and can transition the entire aircraft horizontally into high-speed flight. In this dissertation, we develop the entire control system for a tailsitter with a ducted fan. The standard method to compute the quaternion-based attitude error does not generate ideal trajectories for a hovering tailsitter for some situations. In addition, the only approach in the literature to mitigate this breaks down for large attitude errors. We develop an alternative quaternion-based error method which generates better trajectories than the standard approach and can handle large errors. We also derive a hybrid backstepping controller with almost global asymptotic stability based on this error method. Many common altitude and airspeed control schemes for a fixed-wing airplane assume that the altitude and airspeed dynamics are decoupled which leads to errors. The Total Energy Control System (TECS) is an approach that controls the altitude and airspeed by manipulating the total energy rate and energy distribution rate, of the aircraft, in a manner which accounts for the dynamic coupling. In this dissertation, a nonlinear controller, which can handle inaccurate thrust and drag models, based on the TECS principles is derived. Simulation results show that the nonlinear controller has better performance than the standard PI TECS control schemes. Most constant altitude transitions are accomplished by generating an optimal trajectory, and potentially actuator inputs, based on a high fidelity model of the aircraft. While there are several approaches to mitigate the effects of modeling errors, these do not fully remove the accurate model requirement. In this

  4. Computational Aerodynamic Simulations of a 1484 ft/sec Tip Speed Quiet High-Speed Fan System Model for Acoustic Methods Assessment and Development

    Science.gov (United States)

    Tweedt, Daniel L.

    2014-01-01

    Computational Aerodynamic simulations of a 1484 ft/sec tip speed quiet high-speed fan system were performed at five different operating points on the fan operating line, in order to provide detailed internal flow field information for use with fan acoustic prediction methods presently being developed, assessed and validated. The fan system is a sub-scale, low-noise research fan/nacelle model that has undergone experimental testing in the 9- by 15-foot Low Speed Wind Tunnel at the NASA Glenn Research Center. Details of the fan geometry, the computational fluid dynamics methods, the computational grids, and various computational parameters relevant to the numerical simulations are discussed. Flow field results for three of the five operating points simulated are presented in order to provide a representative look at the computed solutions. Each of the five fan aerodynamic simulations involved the entire fan system, which includes a core duct and a bypass duct that merge upstream of the fan system nozzle. As a result, only fan rotational speed and the system bypass ratio, set by means of a translating nozzle plug, were adjusted in order to set the fan operating point, leading to operating points that lie on a fan operating line and making mass flow rate a fully dependent parameter. The resulting mass flow rates are in good agreement with measurement values. Computed blade row flow fields at all fan operating points are, in general, aerodynamically healthy. Rotor blade and fan exit guide vane flow characteristics are good, including incidence and deviation angles, chordwise static pressure distributions, blade surface boundary layers, secondary flow structures, and blade wakes. Examination of the computed flow fields reveals no excessive or critical boundary layer separations or related secondary-flow problems, with the exception of the hub boundary layer at the core duct entrance. At that location a significant flow separation is present. The region of local flow

  5. Duct Remediation Program: Engineered access research and construction

    International Nuclear Information System (INIS)

    Beckman, T.D.; Davis, M.M.; Karas, T.M.

    1992-01-01

    The Rocky Flats Plant, Duct Remediation mission concentrated on removing Plutonium Oxide from the process ductwork in the primary Plutonium processing facility. When possible, remediation took place from existing process gloveboxes. Fifteen locations were identified, however, that required accessing duct runs where no process gloveboxes existed. The building's second floor utility areas had many locations where long, inaccessible duct runs were prevalent. Consequently, an extensive program for design, procurement and construction was initiated to contain and isolate ducts for penetration when existing glovebox sites were not present

  6. Model Engine Performance Measurement From Force Balance Instrumentation

    Science.gov (United States)

    Jeracki, Robert J.

    1998-01-01

    A large scale model representative of a low-noise, high bypass ratio turbofan engine was tested for acoustics and performance in the NASA Lewis 9- by 15-Foot Low-Speed Wind Tunnel. This test was part of NASA's continuing Advanced Subsonic Technology Noise Reduction Program. The low tip speed fan, nacelle, and an un-powered core passage (with core inlet guide vanes) were simulated. The fan blades and hub are mounted on a rotating thrust and torque balance. The nacelle, bypass duct stators, and core passage are attached to a six component force balance. The two balance forces, when corrected for internal pressure tares, measure the total thrust-minus-drag of the engine simulator. Corrected for scaling and other effects, it is basically the same force that the engine supports would feel, operating at similar conditions. A control volume is shown and discussed, identifying the various force components of the engine simulator thrust and definitions of net thrust. Several wind tunnel runs with nearly the same hardware installed are compared, to identify the repeatability of the measured thrust-minus-drag. Other wind tunnel runs, with hardware changes that affected fan performance, are compared to the baseline configuration, and the thrust and torque effects are shown. Finally, a thrust comparison between the force balance and nozzle gross thrust methods is shown, and both yield very similar results.

  7. Blade Vibration Measurement System for Unducted Fans

    Science.gov (United States)

    Marscher, William

    2014-01-01

    With propulsion research programs focused on new levels of efficiency and noise reduction, two avenues for advanced gas turbine technology are emerging: the geared turbofan and ultrahigh bypass ratio fan engines. Both of these candidates are being pursued as collaborative research projects between NASA and the engine manufacturers. The high bypass concept from GE Aviation is an unducted fan that features a bypass ratio of over 30 along with the accompanying benefits in fuel efficiency. This project improved the test and measurement capabilities of the unducted fan blade dynamic response. In the course of this project, Mechanical Solutions, Inc. (MSI) collaborated with GE Aviation to (1) define the requirements for fan blade measurements; (2) leverage MSI's radar-based system for compressor and turbine blade monitoring; and (3) develop, validate, and deliver a noncontacting blade vibration measurement system for unducted fans.

  8. T-method duct design. Part 3

    International Nuclear Information System (INIS)

    Tsal, R.J.; Behls, H.F.; Mangel, R.

    1990-01-01

    This paper introduces a new method for simulating HVAC duct systems, called T-method. The desirability of simulation appears in many HVAC problems, such as determining system operating efficiency, system retrofitting, nuclear plant normal/emergency conditions, fire/smoke control systems, fans operating in parallel, pressure balancing after system modification, and noise generated by dampers. T-method is capable of simulating these problems. This paper includes problem definition, a theoretical approach, calculation procedures, and many examples

  9. Physics of Acoustic Radiation from Jet Engine Inlets

    Science.gov (United States)

    Tam, Christopher K. W.; Parrish, Sarah A.; Envia, Edmane; Chien, Eugene W.

    2012-01-01

    Numerical simulations of acoustic radiation from a jet engine inlet are performed using advanced computational aeroacoustics (CAA) algorithms and high-quality numerical boundary treatments. As a model of modern commercial jet engine inlets, the inlet geometry of the NASA Source Diagnostic Test (SDT) is used. Fan noise consists of tones and broadband sound. This investigation considers the radiation of tones associated with upstream propagating duct modes. The primary objective is to identify the dominant physical processes that determine the directivity of the radiated sound. Two such processes have been identified. They are acoustic diffraction and refraction. Diffraction is the natural tendency for an acoustic wave to follow a curved solid surface as it propagates. Refraction is the turning of the direction of propagation of sound waves by mean flow gradients. Parametric studies on the changes in the directivity of radiated sound due to variations in forward flight Mach number and duct mode frequency, azimuthal mode number, and radial mode number are carried out. It is found there is a significant difference in directivity for the radiation of the same duct mode from an engine inlet when operating in static condition and in forward flight. It will be shown that the large change in directivity is the result of the combined effects of diffraction and refraction.

  10. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 2; BFaNS User's Manual and Developer's Guide

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the second volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User s Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by step-by-step instructions for installing and running BFaNS. It concludes with technical documentation of the BFaNS computer program.

  11. Dynamic Analysis for a Geared Turbofan Engine with Variable Area Fan Nozzle

    Science.gov (United States)

    Csank, Jeffrey T.; Thomas, George L.

    2017-01-01

    Aggressive design goals have been set for future aero-propulsion systems with regards to fuel economy, noise, and emissions. To meet these challenging goals, advanced propulsion concepts are being explored and current operating margins are being re-evaluated to find additional concessions that can be made. One advanced propulsion concept being evaluated is a geared turbofan with a variable area fan nozzle (VAFN), developed by NASA. This engine features a small core, a fan driven by the low pressure turbine through a reduction gearbox, and a shape memory alloy (SMA)-actuated VAFN. The VAFN is designed to allow both a small exit area for efficient operation at cruise, while being able to open wider at high power conditions to reduce backpressure on the fan and ensure a safe level of stall margin is maintained. The VAFN is actuated via a SMA-based system instead of a conventional system to decrease overall weight of the system, however, SMA-based actuators respond relatively slowly, which introduces dynamic issues that are investigated in this work. This paper describes both a control system designed specifically for issues associated with SMAs, and dynamic analysis of the geared turbofan VAFN with the SMA actuators. Also, some future recommendations are provided for this type of propulsion system.

  12. Optimum design of the injection duct system of a stenter machine

    Energy Technology Data Exchange (ETDEWEB)

    Juraeva, Makhsuda; Song, Dong Joo [Yeungnam University, Geyongsan (Korea, Republic of); Ryu, Kyung Jin [Ajou Motor College, Boryeong (Korea, Republic of)

    2017-05-15

    Stenter machines are used for drying fabrics in the textile industry and have a heater, injection duct system, and fans inside a chamber. The injection duct system has ducts and air-injecting holes. Plane-type injection duct systems were investigated to obtain uniform airflow at the air-injecting holes. The flow field of the injection duct systems was computed using ANSYS CFX with different heights of the duct end and different shapes for the air-injecting holes. There was a high mass flow rate at the air-injecting holes and high airflow circulation inside both plane-type and mountain-type ducts at the ends. The height of the duct end was varied between 40 mm and 160 mm. The injection duct systems were analyzed with four different shapes of air-injecting holes. The circular and elliptical holes had lower standard deviations of the mass flow rate than other shapes. Relatively uniform mass flow rates were obtained in the plane-type and mountain-type duct systems when the height of the duct end was 40 mm and the shape of the air-injecting holes was circular or elliptical. The developed injection duct systems were improved by obtaining a uniform mass flow rate at the air-injecting holes. A stenter prototype was fabricated with the developed injection duct system to confirm the numerical results. The developed injection duct system had better performance than the original system.

  13. Mine ventilation engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hall, C.J.

    1981-01-01

    This book on mine ventilation covers psychometrics, airflow through roadways and ducts, natural ventilation, fans, instruments, ventilation surveys, auxiliary ventilation, air quality, and planning and economics.

  14. Aero-Propulsion Technology (APT) Task V Low Noise ADP Engine Definition Study

    Science.gov (United States)

    Holcombe, V.

    2003-01-01

    A study was conducted to identify and evaluate noise reduction technologies for advanced ducted prop propulsion systems that would allow increased capacity operation and result in an economically competitive commercial transport. The study investigated the aero/acoustic/structural advancements in fan and nacelle technology required to match or exceed the fuel burned and economic benefits of a constrained diameter large Advanced Ducted Propeller (ADP) compared to an unconstrained ADP propulsion system with a noise goal of 5 to 10 EPNDB reduction relative to FAR 36 Stage 3 at each of the three measuring stations namely, takeoff (cutback), approach and sideline. A second generation ADP was selected to operate within the maximum nacelle diameter constrain of 160 deg to allow installation under the wing. The impact of fan and nacelle technologies of the second generation ADP on fuel burn and direct operating costs for a typical 3000 nm mission was evaluated through use of a large, twin engine commercial airplane simulation model. The major emphasis of this study focused on fan blade aero/acoustic and structural technology evaluations and advanced nacelle designs. Results of this study have identified the testing required to verify the interactive performance of these components, along with noise characteristics, by wind tunnel testing utilizing and advanced interaction rig.

  15. On-Board Real-Time Optimization Control for Turbo-Fan Engine Life Extending

    Science.gov (United States)

    Zheng, Qiangang; Zhang, Haibo; Miao, Lizhen; Sun, Fengyong

    2017-11-01

    A real-time optimization control method is proposed to extend turbo-fan engine service life. This real-time optimization control is based on an on-board engine mode, which is devised by a MRR-LSSVR (multi-input multi-output recursive reduced least squares support vector regression method). To solve the optimization problem, a FSQP (feasible sequential quadratic programming) algorithm is utilized. The thermal mechanical fatigue is taken into account during the optimization process. Furthermore, to describe the engine life decaying, a thermal mechanical fatigue model of engine acceleration process is established. The optimization objective function not only contains the sub-item which can get fast response of the engine, but also concludes the sub-item of the total mechanical strain range which has positive relationship to engine fatigue life. Finally, the simulations of the conventional optimization control which just consider engine acceleration performance or the proposed optimization method have been conducted. The simulations demonstrate that the time of the two control methods from idle to 99.5 % of the maximum power are equal. However, the engine life using the proposed optimization method could be surprisingly increased by 36.17 % compared with that using conventional optimization control.

  16. Sound attenuations of axial fan blade tones using flow-driven tunable resonator arrays

    Science.gov (United States)

    Gorny, Lee James

    Flow-excited, tunable quarter-wavelength resonators can be integrated into the shrouds of ducted subsonic axial fans. This study explores their effectiveness in reducing propagations of tonal noise by means of acoustic wave cancellation. Resonators are a non-intrusive method of generating a secondary sound field near the plane of a rotor. As they can be strategically tuned to reduce radiated noise at the blade passage frequency (BPF) and its harmonics, resonators can be useful for a variety of applications to quiet existing and future turbomachinery. Experiments have demonstrated that a single quarter wave resonator is effective in reducing unidirectional plane wave propagations for long wavelength ducted applications while an array is effective for shorter wavelength or un-ducted facilities where shrouded fans are used. Testing conducted at Center for Acoustics and Vibrations (CAV) at the Pennsylvania State University the Deutsches Zentrum fur Luft und Raumfahrt (DLR) in Berlin, Germany demonstrated that resonator arrays were effective in attenuating shorter wavelength plane-wave and higher order modal propagations of blade tone noise. A chiller fan enclosure, constructed in the CAV laboratory emulated an industrial chiller in its operation. Using this facility, resonators were observed to attenuate blade tone noise from a non-ideal ducted geometry. The approaches used in this study evolved from Helmholtz resonators to conventional quarter wave tubes, to mouth tunable resonators, and finally to back-wall tunable resonators. These developments in tuning allowed for independent control of a resonator's magnitude and phase of the secondary sound field produced by the resonators. It was demonstrated that the use of two tunable resonator chambers oriented axially on either side of the blade region enables a dipole-like secondary sound field to be passively generated and bi-directional attenuations of plane wave noise to be achieved. Tonal attenuations of 28 dB were

  17. Preliminary Evaluation of a Turbine/Rotary Combustion Compound Engine for a Subsonic Transport. [fuel consumption and engine tests of turbofan engines

    Science.gov (United States)

    Civinskas, K. C.; Kraft, G. A.

    1976-01-01

    The fuel consumption of a modern compound engine with that of an advanced high pressure ratio turbofan was compared. The compound engine was derived from a turbofan engine by replacing the combustor with a rotary combustion (RC) engine. A number of boost pressure ratios and compression ratios were examined. Cooling of the RC engine was accomplished by heat exchanging to the fan duct. Performance was estimated with an Otto-cycle for two levels of energy lost to cooling. The effects of added complexity on cost and maintainability were not examined and the comparison was solely in terms of cruise performance and weight. Assuming a 25 percent Otto-cycle cooling loss (representative of current experience), the best compound engine gave a 1.2 percent improvement in cruise. Engine weight increased by 23 percent. For a 10 percent Otto-cycle cooling loss (representing advanced insulation/high temperature materials technology), a compound engine with a boost PR of 10 and a compression ratio of 10 gave an 8.1 percent lower cruise than the reference turbofan.

  18. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 1; Setup_BFaNS User's Manual and Developer's Guide

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the first volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User's Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by step-by-step instructions for installing and running Setup_BFaNS. It concludes with technical documentation of the Setup_BFaNS computer program.

  19. ECOLO-HOUSE in the heavy snow-fall region. Study of the ventilating function that the heat collecting system of the air duct utilizing attic has; Yukiguni ECOLO-HOUSE. Kison kaoku no yaneura wo riyoshita duct shunetsu system kanki kino hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Umemiya, H; Hirosawa, K [Yamagata University, Yamagata (Japan)

    1997-11-25

    This paper reports a duct heat collecting system installed in the ECOLO-HOUSE for snow countries. This system is an air heat collecting system of the outside air introducing type utilizing as a solar heat collector the single pitch roof often seen in snow countries. Outside air is introduced from below eaves into a heat collecting duct made by nailing plywoods onto rafters from the attic side to collect heat on the roof. Operating a sirocco fan connected to the induction duct located on the high-floor foundation sucks outside air from an air intake opening under the eaves into the heat collecting duct. Air which has absorbed heat on the roof and been warmed in the heat collecting duct by insolation goes into a heat collecting chamber. The air is sent into the high-floor foundation through the induction duct laid from the heat collecting chamber. Air is exchanged 8.7 times by the fan when it is operated all day continuously. Condensation in the fuel chamber floor and walls during the rainy season has disappeared, and so has odor at the same time. As a result of the humidity measurement, a location into which warm air is sent has difference in humidity as great as 15% from a location where no warm air is sent. 2 refs., 6 figs., 2 tabs.

  20. Evaluating the Acoustic Benefits of Over-the-Rotor Acoustic Treatments Installed on the Advanced Noise Control Fan

    Science.gov (United States)

    Gazella, Matthew R.; Takakura, Tamuto; Sutliff, Daniel L.; Bozak, Richard F.; Tester, Brian J.

    2017-01-01

    Over the last 15 years, over-the-rotor acoustic treatments have been evaluated by NASA with varying success. Recently, NASA has been developing the next generation of over-the-rotor acoustic treatments for fan noise reduction. The NASA Glenn Research Centers Advanced Noise Control Fan was used as a Low Technology Readiness Level test bed. A rapid prototyped in-duct array consisting of 50 microphones was employed, and used to correlate the in-duct analysis to the far-field acoustic levels and to validate an existing beam-former method. The goal of this testing was to improve the Technology Readiness Level of various over-the-rotor acoustic treatments by advancing the understanding of the physical mechanisms and projecting the far-field acoustic benefit.

  1. Ducted combustion chamber for direct injection engines and method

    Science.gov (United States)

    Mueller, Charles

    2015-03-03

    An internal combustion engine includes an engine block having a cylinder bore and a cylinder head having a flame deck surface disposed at one end of the cylinder bore. A piston connected to a rotatable crankshaft and configured to reciprocate within the cylinder bore has a piston crown portion facing the flame deck surface such that a combustion chamber is defined within the cylinder bore and between the piston crown and the flame deck surface. A fuel injector having a nozzle tip disposed in fluid communication with the combustion chamber has at least one nozzle opening configured to inject a fuel jet into the combustion chamber along a fuel jet centerline. At least one duct defined in the combustion chamber between the piston crown and the flame deck surface has a generally rectangular cross section and extends in a radial direction relative to the cylinder bore substantially along the fuel jet centerline.

  2. Effect of inlet straighteners on centrifugal fan performance

    Energy Technology Data Exchange (ETDEWEB)

    Bayomi, N.N.; Abdel Hafiz, A. [Faculty of Engineering, Mataria, Helwan University, 11718 Masaken, El-Helmia, Cairo (Egypt); Osman, A.M. [Faculty of Engineering, Shoubra, Zagazig University, Cairo (Egypt)

    2006-11-15

    The use of straighteners in the inlet duct of centrifugal fans is suggested for eliminating any inlet distortion. An experimental investigation was performed to study the effect of inlet straighteners on the performance characteristics of centrifugal fans. Two types of straighteners were used, circular tubes and zigzag cross section, with different lengths. Circular tubes with different diameters have been investigated. The study was conducted on three types of fans, namely radial, backward with exit blade angles 60{sup o} and 75{sup o} and forward with 105{sup o} and 120{sup o}. The results confirm that the inlet straighteners exhibit different effects on the fan performance for the different blade angles. Accordingly, the results indicate the selection of long circular tube straighteners with large diameter for radial blades, long zigzag type for backward 60{sup o} blade angle and short zigzag type for backward 75{sup o} blade angle. Generally, good improvements in efficiency are observed for radial and backward blades on account of a slight drop in static head. In addition, an increase in the flow margin up to 12% and a decrease in the noise level from 3 to 5dB are indicated compared to the free inlet condition. On the contrary, unfavorable influences are exerted on the forward fan performance. (author)

  3. High-frequency data observations from space shuttle main engine low pressure fuel turbopump discharge duct flex joint tripod failure investigation

    Science.gov (United States)

    Zoladz, T. F.; Farr, R. A.

    1991-01-01

    Observations made by Marshall Space Flight Center (MSFC) engineers during their participation in the Space Shuttle Main Engine (SSME) low pressure fuel turbopump discharge duct flex joint tripod failure investigation are summarized. New signal processing techniques used by the Component Assessment Branch and the Induced Environments Branch during the failure investigation are described in detail. Moreover, nonlinear correlations between frequently encountered anomalous frequencies found in SSME dynamic data are discussed. A recommendation is made to continue low pressure fuel (LPF) duct testing through laboratory flow simulations and MSFC-managed technology test bed SSME testing.

  4. Ballistic and Cyclic Rig Testing of Braided Composite Fan Case Structures

    Science.gov (United States)

    Watson, William R.; Roberts, Gary D.; Pereira, J. Michael; Braley, Michael S.

    2015-01-01

    FAA fan blade-out certification testing on turbofan engines occurs very late in an engine's development program and is very costly. It is of utmost importance to approach the FAA Certification engine test with a high degree of confidence that the containment structure will not only contain the high-energy debris, but that it will also withstand the cyclic loads that occur with engine spooldown and continued rotation as the non-running engine maintains a low rotor RPM due to forced airflow as the engine-out aircraft returns to an airport. Accurate rig testing is needed for predicting and understanding material behavior of the fan case structure during all phases of this fan blade-out event.

  5. Dual fan, dual-duct system meets air quality, energy-efficiency needs

    Energy Technology Data Exchange (ETDEWEB)

    Schuler, M. [Pageau Morel and Associates, Montreal, Quebec (Canada)

    1996-03-01

    Canada`s Space Centre in Saint-Hubert Quebec is a 300,000 ft{sup 2} (27,871 m{sup 2}) complex that houses the headquarters of the Canadian Space Agency, the Canadian Astronaut Training Centre, mission ground control installations, research facilities, offices and the required support facilities. A comfortable, pleasant research environment was a primary concern for the Space Centre, given its elite clientele. The objectives were high indoor-air quality, design flexibility, energy efficiency and low capital costs. Dual duct systems which are the heart of the mechanical concept allowed the designers to meet these objectives. The Space Centre`s offices, laboratories and conference center are all served by dual-duct systems. All operate using an air economizer cycle. Gas boilers provide them with hot water for heating and steam for humidification while centrifugal chillers provide chilled water for cooling. This article describes the design.

  6. Improving the energy efficiency of mine fan assemblages

    International Nuclear Information System (INIS)

    De Souza, Euler

    2015-01-01

    Energy associated with ventilating an underground operation comprises a significant portion of a mine operation's base energy demand and is consequently responsible for a large percentage of the total operating costs. Ventilation systems may account from 25 to 40% of the total energy costs and 40–50% of the energy consumption of a mine operation. Fans are the most important mechanical devices used to ventilate underground mines and the total fan power installed in a single mine operation can easily exceed 10,000 kW. Investigations of a number of mine main fan installations have determined their assemblage to be, in general, very energy inefficient. The author has found that 40–80% of the energy consumed by a main fan is used to overcome the resistance of fan assemblage components. This paper presents how engineering design principles can be applied to improve the performance and efficiency of fan installations, resulting in substantial reductions in power consumption, operating cost and greenhouse gas emissions. A detailed case study is presented to demonstrate that, by designing fan assemblages using proper engineering concepts of fluid physics and industrial ventilation design, main fan systems will operate at efficiencies well above 80–90% (compared to common operating efficiencies of between 20 and 65%), resulting in a drastic reduction in a mine's overall costs and base electrical and energy loads. - Highlights: • Increases in fan assemblage efficiencies with minimum capital investment. • Improved designs for substantial fan power and operating cost savings. • General solutions and tactics for improving existing main fan installations. • Case study presented to demonstrate proper design of fan assemblages.

  7. Thermal performance analysis of Brayton cycle with waste heat recovery boiler for diesel engines of offshore oil production facilities

    International Nuclear Information System (INIS)

    Liu, Xianglong; Gong, Guangcai; Wu, Yi; Li, Hangxin

    2016-01-01

    Highlights: • Comparison of Brayton cycle with WHRB adopted in diesel engines with and without fans by thermal performance. • Waste heat recovery technology for FPSO. • The thermoeconomic analysis for the heat recovery for FPSO. - Abstract: This paper presents the theoretical analysis and on-site testing on the thermal performance of the waste heat recovery system for offshore oil production facilities, including the components of diesel engines, thermal boilers and waste heat boilers. We use the ideal air standard Brayton cycle to analyse the thermal performance. In comparison with the traditional design, the fans at the engine outlet of the waste heat recovery boiler is removed due to the limited space of the offshore platform. The cases with fan and without fan are compared in terms of thermal dynamics performance, energy efficiency and thermo-economic index of the system. The results show that the application of the WHRB increases the energy efficiency of the whole system, but increases the flow resistance in the duct. It is proved that as the waste heat recovery boiler takes the place of the thermal boiler, the energy efficiency of whole system without fan is slightly reduced but heat recovery efficiency is improved. This research provides an important guidance to improve the waste heat recovery for offshore oil production facilities.

  8. Numerical Investigation of Effect of Parameters on Hovering Efficiency of an Annular Lift Fan Aircraft

    Directory of Open Access Journals (Sweden)

    Yun Jiang

    2016-10-01

    Full Text Available The effects of various parameters on the hovering performance of an annular lift fan aircraft are investigated by using numerical scheme. The pitch angle, thickness, aspect ratio (chord length, number of blades, and radius of duct inlet lip are explored to optimize the figure of merit. The annular lift fan is also compared with a conventional circular lift fan of the same features with the same disc loading and similar geometry. The simulation results show that the pitch angle of 27°, the thickness of 4% chord length, the aspect ratio of 3.5~4.0, 32 blades, and the radius of inlet lip of 4.7% generate the maximum figure of merit of 0.733. The optimized configuration can be used for further studies of the annular lift fan aircraft.

  9. Characterization of Composite Fan Case Resins

    Science.gov (United States)

    Dvoracek, Charlene M.

    2004-01-01

    The majority of commercial turbine engines that power today s aircraft use a large fan driven by the engine core to generate thrust which dramatically increases the engine s efficiency. However, if one of these fan blades fails during flight, it becomes high energy shrapnel, potentially impacting the engine or puncturing the aircraft itself and thus risking the lives of passengers. To solve this problem, the fan case must be capable of containing a fan blade should it break off during flight. Currently, all commercial fan cases are made of either just a thick metal barrier or a thinner metal wall surrounded by Kevlar-an ultra strong fiber that elastically catches the blade. My summer 2004 project was to characterize the resins for a composite fan case that will be lighter and more efficient than the current metal. The composite fan case is created by braiding carbon fibers and injecting a polymer resin into the braid. The resin holds the fibers together, so at first using the strongest polymer appears to logically lead to the strongest fan case. Unfortunately, the stronger polymers are too viscous when melted. This makes the manufacturing process more difficult because the polymer does not flow as freely through the braid, and the final product is less dense. With all of this in mind, it is important to remember that the strength of the polymer is still imperative; the case must still contain blades with high impact energy. The research identified which polymer had the right balance of properties, including ease of fabrication, toughness, and ability to transfer the load to the carbon fibers. Resin deformation was studied to better understand the composite response during high speed impact. My role in this research was the testing of polymers using dynamic mechanical analysis and tensile, compression, and torsion testing. Dynamic mechanical analysis examines the response of materials under cyclic loading. Two techniques were used for dynamic mechanical analysis

  10. Development trend of high bypass ratio turbofan engines. Ko baipasu hi tabo fan engine no kaihatsu doko

    Energy Technology Data Exchange (ETDEWEB)

    Tonomura, Y [Mitsubishi Heavy Industries Ltd., Tokyo (Japan)

    1994-03-10

    The turbofan engines for private aircrafts have come to have a high bypass ratio because a performance improvement is always requested. Because a turbofan engine is always required for a thrust reinforcement to correspond the stretch and weight increase of a fuselage after acquiring a type approval, making them a series to cover a certain thrust range becomes necessary. The concrete methods to reinforce a thrust are being achieved by an increase of fan diameter, a partial modification of high pressure compressor, a temperature rise of high pressure turbine inlet, a stage number increase of low pressure turbine, and a combination of these items just mentioned above. The PW 4000 series, CF6 series and RB211 series currently under production are being reinforced in a thrust by these methods. In this paper, as the representatives of some turbofan engines incorporating the most advanced technologies, as for 3 kinds of the large scale turbofan engine presently under development for the B777, namely GE90, PW4084, and TRENT800, their distinctive futures are summarized. 25 figs., 1 tab.

  11. Advanced Prop-fan Engine Technology (APET) single- and counter-rotation gearbox/pitch change mechanism

    Science.gov (United States)

    Reynolds, C. N.

    1985-01-01

    The preliminary design of advanced technology (1992) turboprop engines for single-rotation prop-fans and conceptual designs of pitch change mechanisms for single- and counter-rotation prop-fan application are discussed. The single-rotation gearbox is a split path, in-line configuration. The counter-rotation gearbox is an in-line, differential planetary design. The pitch change mechanisms for both the single- and counter-rotation arrangements are rotary/hydraulic. The advanced technology single-rotation gearbox yields a 2.4 percent improvement in aircraft fuel burn and a one percent improvement in operating cost relative to a current technology gearbox. The 1992 counter-rotation gearbox is 15 percent lighter, 15 percent more reliable, 5 percent lower in cost, and 45 percent lower in maintenance cost than the 1992 single-rotation gearbox. The pitch controls are modular, accessible, and external.

  12. Quiet High Speed Fan II (QHSF II): Final Report

    Science.gov (United States)

    Kontos, Karen; Weir, Don; Ross, Dave

    2012-01-01

    This report details the aerodynamic, mechanical, structural design and fabrication of a Honey Engines Quiet High Speed Fan II (lower hub/tip ratio and higher specific flow than the Baseline I fan). This fan/nacelle system incorporates features such as advanced forward sweep and an advanced integrated fan/fan exit guide vane design that provides for the following characteristics: (1) Reduced noise at supersonic tip speeds, in comparison to current state-of-the-art fan technology; (2) Improved aeroelastic stability within the anticipated operating envelope; and (3) Aerodynamic performance consistent with current state-of-the-art fan technology. This fan was fabricated by Honeywell and tested in the NASA Glenn 9- by 15-Ft Low Speed Wind Tunnel for aerodynamic, aeromechanical, and acoustic performance.

  13. Conceptual study of advanced VTOL transport aircraft engine; Kosoku VTOL kiyo engine no gainen kento

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y; Endo, M; Matsuda, Y; Sugiyama, N; Watanabe, M; Sugahara, N; Yamamoto, K [National Aerospace Laboratory, Tokyo (Japan)

    1996-04-01

    This report proposes the concept of an ultra-low noise engine for advanced high subsonic VTOL transport aircraft, and discusses its technological feasibility. As one of the applications of the previously reported `separated core turbofan engine,` the conceptual engine is composed of 3 core engines, 2 cruise fan engines for high subsonic cruising and 6 lift fan engines producing thrust of 98kN (10000kgf)/engine. The core turbojet engine bleeds a large amount of air at the outlet of a compressor to supply driving high-pressure air for fans to other engines. The lift fan engine is composed of a lift fan, driving combustor, turbine and speed reduction gear, and is featured by not only high operation stability and thin fan engine like a separated core engine but also ultra-low noise operation. The cruise fan engine adopts the same configuration as the lift fan engine. Since this engine configuration has no technological problems difficult to be overcome, its high technological feasibility is expected. 6 refs., 7 figs., 5 tabs.

  14. Impeller Design of a Centrifugal Fan with Blade Optimization

    OpenAIRE

    Lee, Yu-Tai; Ahuja, Vineet; Hosangadi, Ashvin; Slipper, Michael E.; Mulvihill, Lawrence P.; Birkbeck, Roger; Coleman, Roderick M.

    2011-01-01

    A method is presented for redesigning a centrifugal impeller and its inlet duct. The double-discharge volute casing is a structural constraint and is maintained for its shape. The redesign effort was geared towards meeting the design volute exit pressure while reducing the power required to operate the fan. Given the high performance of the baseline impeller, the redesign adopted a high-fidelity CFD-based computational approach capable of accounting for all aerodynamic losses. The present eff...

  15. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  16. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-16

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  17. Investigation of Unsteady Flow Interaction Between an Ultra-Compact Inlet and a Transonic Fan

    Science.gov (United States)

    Hah, Chunill; Rabe, Douglas; Scribben, Angie

    2015-01-01

    In the present study, unsteady flow interaction between an ultra-compact inlet and a transonic fan stage is investigated. Future combat aircraft require ultra-compact inlet ducts as part of an integrated, advanced propulsion system to improve air vehicle capability and effectiveness to meet future mission needs. The main purpose of the study is to advance the current understanding of the flow interaction between two different ultra-compact inlets and a transonic fan for future design applications. Both URANS and LES approaches are used to calculate the unsteady flow field and are compared with the available measured data. The present study indicates that stall inception is mildly affected by the distortion pattern generated by the inlet with the current test set-up. The numerical study indicates that the inlet distortion pattern decays significantly before it reaches the fan face for the current configuration. Numerical results with a shorter distance between the inlet and fan show that counter-rotating vortices near the rotor tip due to the serpentine diffuser affects fan characteristics significantly.

  18. Fundamental investigation on the impact strength of hollow fan blades

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, T; Miyachi, T; Sofue, Y

    1985-01-01

    Models of hollow fan blades were made and tested to prove that their strength is sufficient for use in real engines. The hollow blades were fabricated by diffusion bonding of two titanium alloy (6Al-4V-Ti) plates, one of which had three spanwise stiffners and the other being flat plate. The model as a nontwisted tapered blade. Impact tests were carried out on the hollow fan blade models in which the ingestion of a 1.5 pounds bird was simulated. Solid blades with the same external form were also tested by similar methods for comparison. The results of these tests show that properly designed hollow blades have sufficient stiffness and strength for use as fan blades in the turbo-fan engine.

  19. On the interaction of a fan stator and acoustic treatments using the transfer element method

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xiaoyu; Sun Xiaofeng [Fluid and Acoustic Engineering Laboratory, Beijing University of Aeroacoustics and Astronautics, Beijing 100083 (China)], E-mail: Sunxf@buaa.edu.cn

    2010-02-15

    In the present investigation, a theoretical model is suggested to study the interaction of a fan stator and acoustic treatments using the transfer element method. Firstly, the solution of an acoustic field caused by a fan stator in an infinite duct is extended to that in a finite domain with all knowns and unknowns on the interface plane. Secondly, the related numerical results for an annular cascade are compared with the data obtained by directly solving an integral equation based on the blade boundary condition, which have good agreement with each other. Finally, more emphasis is placed on studying how a fan stator interacts with both upstream and downstream acoustic treatments. It is found that the interaction has an important influence on sound attenuation. In addition, optimal sound attenuation will depend on the combined design of both acoustic treatment and the fan stator. (invited paper)

  20. On the interaction of a fan stator and acoustic treatments using the transfer element method

    International Nuclear Information System (INIS)

    Wang Xiaoyu; Sun Xiaofeng

    2010-01-01

    In the present investigation, a theoretical model is suggested to study the interaction of a fan stator and acoustic treatments using the transfer element method. Firstly, the solution of an acoustic field caused by a fan stator in an infinite duct is extended to that in a finite domain with all knowns and unknowns on the interface plane. Secondly, the related numerical results for an annular cascade are compared with the data obtained by directly solving an integral equation based on the blade boundary condition, which have good agreement with each other. Finally, more emphasis is placed on studying how a fan stator interacts with both upstream and downstream acoustic treatments. It is found that the interaction has an important influence on sound attenuation. In addition, optimal sound attenuation will depend on the combined design of both acoustic treatment and the fan stator. (invited paper)

  1. Design and Testing of Braided Composite Fan Case Materials and Components

    Science.gov (United States)

    Roberts, Gary D.; Pereira, J. Michael; Braley, Michael S.; Arnold, William a.; Dorer, James D.; Watson, William R/.

    2009-01-01

    Triaxial braid composite materials are beginning to be used in fan cases for commercial gas turbine engines. The primary benefit for the use of composite materials is reduced weight and the associated reduction in fuel consumption. However, there are also cost benefits in some applications. This paper presents a description of the braided composite materials and discusses aspects of the braiding process that can be utilized for efficient fabrication of composite cases. The paper also presents an approach that was developed for evaluating the braided composite materials and composite fan cases in a ballistic impact laboratory. Impact of composite panels with a soft projectile is used for materials evaluation. Impact of composite fan cases with fan blades or blade-like projectiles is used to evaluate containment capability. A post-impact structural load test is used to evaluate the capability of the impacted fan case to survive dynamic loads during engine spool down. Validation of these new test methods is demonstrated by comparison with results of engine blade-out tests.

  2. Separated core turbofan engine; Core bunrigata turbofan engine

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y; Endo, M; Matsuda, Y; Sugiyama, N; Sugahara, N; Yamamoto, K [National Aerospace Laboratory, Tokyo (Japan)

    1996-04-01

    This report outlines the separated core turbofan engine. This engine is featured by parallel separated arrangement of a fan and core engine which are integrated into one unit in the conventional turbofan engine. In general, cruising efficiency improvement and noise reduction are achieved by low fan pressure ratio and low exhaust speed due to high bypass ratio, however, it causes various problems such as large fan and nacelle weight due to large air flow rate of a fan, and shift of an operating point affected by flight speed. The parallel separated arrangement is thus adopted. The stable operation of a fan and core engine is easily retained by independently operating air inlet unaffected by fan. The large degree of freedom of combustion control is also obtained by independent combustor. Fast response, simple structure and optimum aerodynamic design are easily achieved. This arrangement is also featured by flexibility of development and easy maintenance, and by various merits superior to conventional turbofan engines. It has no technological problems difficult to be overcome, and is also suitable for high-speed VTOL transport aircraft. 4 refs., 5 figs.

  3. Transition duct system with arcuate ceramic liner for delivering hot-temperature gases in a combustion turbine engine

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, David J.

    2017-11-07

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include an arcuate connecting segment (36). An arcuate ceramic liner (60) may be inwardly disposed onto a metal outer shell (38) along the arcuate connecting segment of the exit piece. Structural arrangements are provided to securely attach the ceramic liner in the presence of substantial flow path pressurization. Cost-effective serviceability of the transition duct systems is realizable since the liner can be readily removed and replaced as needed.

  4. Structural Analysis and Optimization of a Composite Fan Blade for Future Aircraft Engine

    Science.gov (United States)

    Coroneos, Rula M.

    2012-01-01

    This report addresses the structural analysis and optimization of a composite fan blade sized for a large aircraft engine. An existing baseline solid metallic fan blade was used as a starting point to develop a hybrid honeycomb sandwich construction with a polymer matrix composite face sheet and honeycomb aluminum core replacing the original baseline solid metallic fan model made of titanium. The focus of this work is to design the sandwich composite blade with the optimum number of plies for the face sheet that will withstand the combined pressure and centrifugal loads while the constraints are satisfied and the baseline aerodynamic and geometric parameters are maintained. To satisfy the requirements, a sandwich construction for the blade is proposed with composite face sheets and a weak core made of honeycomb aluminum material. For aerodynamic considerations, the thickness of the core is optimized whereas the overall blade thickness is held fixed so as to not alter the original airfoil geometry. Weight is taken as the objective function to be minimized by varying the core thickness of the blade within specified upper and lower bounds. Constraints are imposed on radial displacement limitations and ply failure strength. From the optimum design, the minimum number of plies, which will not fail, is back-calculated. The ply lay-up of the blade is adjusted from the calculated number of plies and final structural analysis is performed. Analyses were carried out by utilizing the OpenMDAO Framework, developed at NASA Glenn Research Center combining optimization with structural assessment.

  5. Navier-Stokes analysis and experimental data comparison of compressible flow within ducts

    Science.gov (United States)

    Harloff, G. J.; Reichert, B. A.; Sirbaugh, J. R.; Wellborn, S. R.

    1992-01-01

    Many aircraft employ ducts with centerline curvature or changing cross-sectional shape to join the engine with inlet and exhaust components. S-ducts convey air to the engine compressor from the intake and often decelerate the flow to achieve an acceptable Mach number at the engine compressor by increasing the cross-sectional area downstream. Circular-to-rectangular transition ducts are used on aircraft with rectangular exhaust nozzles to connect the engine and nozzle. To achieve maximum engine performance, the ducts should minimize flow total pressure loss and total pressure distortion at the duct exit. Changes in the curvature of the duct centerline or the duct cross-sectional shape give rise to streamline curvature which causes cross stream pressure gradients. Secondary flows can be caused by deflection of the transverse vorticity component of the boundary layer. This vortex tilting results in counter-rotating vortices. Additionally, the adverse streamwise pressure gradient caused by increasing cross-sectional area can lead to flow separation. Vortex pairs have been observed in the exit planes of both duct types. These vortices are due to secondary flows induced by pressure gradients resulting from streamline curvature. Regions of low total pressure are produced when the vortices convect boundary layer fluid into the main flow. The purpose of the present study is to predict the measured flow field in a diffusing S-duct and a circular-to-rectangular transition duct with a full Navier-Stokes computer program, PARC3D, and to compare the numerical predictions with new detailed experimental measurements. The work was undertaken to extend previous studies and to provide additional CFD validation data needed to help model flows with strong secondary flow and boundary layer separation. The S-duct computation extends the study of Smith et al, and Harloff et al, which concluded that the computation might be improved by using a finer grid and more advanced turbulence models

  6. Building America Case Study: Evaluating Through-Wall Air Transfer Fans, Pittsburgh, Pennsylvania (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-10-01

    In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. Four air-based HVAC distribution systems were assessed:-a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  7. Thermal behavior of the duct applied functionally graded material

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Sun; Yoon, Dong Young; Im, Jong Bin [Hankuk Aviation Univ., Goyang (Korea, Republic of)

    2004-07-01

    In Unmanned Aerial Vehicles (UAV), the high temperature results from friction among the air, combustion of fuel in engine and combustion gas of a nozzle. The high temperature may cause serious damages in UAV structure. The Functionally Graded Material(FGM) is chosen as a material of the engine duct structure. Thermal stress analysis of FGM is performed in this paper. FGM is composed of two constituent materials that are mixed up according to the specific volume fraction distribution in order to withstand high temperature. Therefore, hoop stress, axial stress and shear stress of duct with 2 layers, 4 layers and 8 layers FGM are compared and analyzed respectively. In addition, the creep behavior of FGM used in duct structure of an engine is analyzed for better understanding of FGM characteristics.

  8. Transition duct system with straight ceramic liner for delivering hot-temperature gases in a combustion turbine engine

    Science.gov (United States)

    Wiebe, David J.

    2017-05-16

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include a straight path segment (26) for receiving a gas flow from a respective combustor. A straight ceramic liner (40) may be inwardly disposed onto a metal outer shell (38) along the straight path segment of the exit piece. Structural arrangements are provided to securely attach the ceramic liner in the presence of substantial flow path pressurization. Cost-effective serviceability of the transition duct systems is realizable since the liner can be readily removed and replaced as needed.

  9. Results of an Advanced Fan Stage Operating Over a Wide Range of Speed and Bypass Ratio. Part 1; Fan Stage Design and Experimental Results

    Science.gov (United States)

    Suder, Kenneth L.; Prahst, Patricia S.; Thorp, Scott A.

    2011-01-01

    NASA s Fundamental Aeronautics Program is investigating turbine-based combined cycle (TBCC) propulsion systems for access to space because it provides the potential for aircraft-like, space-launch operations that may significantly reduce launch costs and improve safety. To this end, National Aeronautics and Space Administration (NASA) and General Electric (GE) teamed to design a Mach 4 variable cycle turbofan/ramjet engine for access to space. To enable the wide operating range of a Mach 4+ variable cycle turbofan ramjet required the development of a unique fan stage design capable of multi-point operation to accommodate variations in bypass ratio (10 ), fan speed (7 ), inlet mass flow (3.5 ), inlet pressure (8 ), and inlet temperature (3 ). In this paper, NASA has set out to characterize a TBCC engine fan stage aerodynamic performance and stability limits over a wide operating range including power-on and hypersonic-unique "windmill" operation. Herein, we will present the fan stage design, and the experimental test results of the fan stage operating from 15 to 100 percent corrected design speed. Whereas, in the companion paper, we will provide an assessment of NASA s APNASA code s ability to predict the fan stage performance and operability over a wide range of speed and bypass ratio.

  10. Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  11. Jet Engine Bird Ingestion Simulations: Comparison of Rotating to Non-Rotating Fan Blades

    Science.gov (United States)

    Howard, Samuel A.; Hammer, Jeremiah T.; Carney, Kelly S.; Pereira, J. Michael

    2013-01-01

    Bird strike events in commercial airliners are a fairly common occurrence. According to data collected by the US Department of Agriculture, over 80,000 bird strikes were reported in the period 1990 to 2007 in the US alone (Ref. 1). As a result, bird ingestion is an important factor in aero engine design and FAA certification. When it comes to bird impacts on engine fan blades, the FAA requires full-scale bird ingestion tests on an engine running at full speed to pass certification requirements. These rotating tests are complex and very expensive. To reduce development costs associated with new materials for fan blades, it is desirable to develop more cost effective testing procedures than full-scale rotating engine tests for material evaluation. An impact test on a nonrotating single blade that captures most of the salient physics of the rotating test would go a long way towards enabling large numbers of evaluative material screening tests. NASA Glenn Research Center has been working to identify a static blade test procedure that would be effective at reproducing similar results as seen in rotating tests. The current effort compares analytical simulations of a bird strike on various non-rotating blades to a bird strike simulation on a rotating blade as a baseline case. Several different concepts for simulating the rotating loads on a non-rotating blade were analyzed with little success in duplicating the deformation results seen in the rotating case. The rotating blade behaves as if it were stiffer than the non-rotating blade resulting in less plastic deformation from a given bird impact. The key factor limiting the success of the non-rotating blade simulations is thought to be the effect of gyroscopics. Prior to this effort, it was anticipated the difficulty would be in matching the prestress in the blade due to centrifugal forces Additional work is needed to verify this assertion, and to determine if a static test procedure can simulate the gyroscopic effects in

  12. Centrifugal fans: Similarity, scaling laws, and fan performance

    Science.gov (United States)

    Sardar, Asad Mohammad

    Centrifugal fans are rotodynamic machines used for moving air continuously against moderate pressures through ventilation and air conditioning systems. There are five major topics presented in this thesis: (1) analysis of the fan scaling laws and consequences of dynamic similarity on modelling; (2) detailed flow visualization studies (in water) covering the flow path starting at the fan blade exit to the evaporator core of an actual HVAC fan scroll-diffuser module; (3) mean velocity and turbulence intensity measurements (flow field studies) at the inlet and outlet of large scale blower; (4) fan installation effects on overall fan performance and evaluation of fan testing methods; (5) two point coherence and spectral measurements conducted on an actual HVAC fan module for flow structure identification of possible aeroacoustic noise sources. A major objective of the study was to identity flow structures within the HVAC module that are responsible for noise and in particular "rumble noise" generation. Possible mechanisms for the generation of flow induced noise in the automotive HVAC fan module are also investigated. It is demonstrated that different modes of HVAC operation represent very different internal flow characteristics. This has implications on both fan HVAC airflow performance and noise characteristics. It is demonstrated from principles of complete dynamic similarity that fan scaling laws require that Reynolds, number matching is a necessary condition for developing scale model fans or fan test facilities. The physical basis for the fan scaling laws derived was established from both pure dimensional analysis and also from the fundamental equations of fluid motion. Fan performance was measured in a three times scale model (large scale blower) in air of an actual forward curved automotive HVAC blower. Different fan testing methods (based on AMCA fan test codes) were compared on the basis of static pressure measurements. Also, the flow through an actual HVAC

  13. Reduction of Discrete-Frequency Fan Noise Using Slitlike Expansion Chambers

    Directory of Open Access Journals (Sweden)

    Akira Sadamoto

    2003-01-01

    Full Text Available As is generally known, discrete-frequency noises are radiated from fans due to rotor-stator interaction. Their fundamental frequency is the blade-passage frequency, which is determined by the number of rotor blades and their rotating speeds. To reduce such noises, several types of silencers have been designed. Among them, the authors noted a slitlike expansion chamber (hereafter referred to as slit, for simplicity and have studied its performance. A slit is a simple expansion chamber with a very short axial length that is placed in a duct. A slit with a circular cross-section that is concentric with a circular duct may be studied using the same interpretation as is used for a side-branch resonator muffler (closed-end tube connected to a duct; that is, the resonant frequency of a slit depends on its depth (with an open-end correction. It is expected, hence, that a slit might be applicable as a simple and axially compact silencer that is effective on discrete-frequency noises. In this article, the properties of a slit are introduced, and the applicability of a slit to actual rotating machinery is described using experimental data.

  14. Consistent approach to air-cleaning system duct design

    International Nuclear Information System (INIS)

    Miller, W.H.; Ornberg, S.C.; Rooney, K.L.

    1981-01-01

    Nuclear power plant air-cleaning system effectiveness is dependent on the capability of a duct system to safely convey contaminated gas to a filtration unit and subsequently to a point of discharge. This paper presents a logical and consistent design approach for selecting sheet metal ductwork construction to meet applicable criteria. The differences in design engineers' duct construction specifications are acknowledged. Typical duct construction details and suggestions for their effective use are presented. Improvements in duct design sections of ANSI/ASME N509-80 are highlighted. A detailed leakage analysis of a control room HVAC system is undertaken to illustrate the effects of conceptual design variations on duct construction requirements. Shortcomings of previously published analyses and interpretations of a current standard are included

  15. Experimental Evaluation of a Low Emissions High Performance Duct Burner for Variable Cycle Engines (VCE)

    Science.gov (United States)

    Lohmann, R. P.; Mador, R. J.

    1979-01-01

    An evaluation was conducted with a three stage Vorbix duct burner to determine the performance and emissions characteristics of the concept and to refine the configuration to provide acceptable durability and operational characteristics for its use in the variable cycle engine (VCE) testbed program. The tests were conducted at representative takeoff, transonic climb, and supersonic cruise inlet conditions for the VSCE-502B study engine. The test stand, the emissions sampling and analysis equipment, and the supporting flow visualization rigs are described. The performance parameters including the fuel-air ratio, the combustion efficiency/exit temperature, thrust efficiency, and gaseous emissions calculations are defined. The test procedures are reviewed and the results are discussed.

  16. Vibroacoustic Analysis of a Refrigerator Freezer Cabinet Coupled with an Air Duct

    Directory of Open Access Journals (Sweden)

    Onur Çelikkan

    2017-01-01

    Full Text Available In this study, the vibration and acoustic interactions between the structure and the cavity inside the freezer cabinet were investigated. Thus, a set of numerical and experimental analyses were performed. In the numerical analysis, the acoustic characteristics of the freezer cavity were solved, and the mixed finite element method was then implemented to analyse the coupled behaviour of the cavity with the air duct using the Acoustic Fluid-Structure Interaction (AFSI technique. In the experimental analyses, an acoustic modal analysis of the freezer cavity and a structural modal analysis of the air duct were performed for the validation process. A good agreement was obtained among the results. Thus, the accuracy of the numerical model was confirmed. The validated models were used for optimizing the design. To solve the noise generation mechanism inside the freezer cabinet, the noise primarily generated by the freezer fan unit was measured under normal working conditions of the refrigerator, and the resonance frequencies were obtained. This information was compared with the normal modes of the air duct, and the overlapping frequencies were identified. To reduce the interaction between the source and the structure, a few design modifications were applied to the air duct. Thus, the structural-borne noise radiating from the air duct into the freezer cavity was reduced.

  17. Noise Measurements of the VAIIPR Fan

    Science.gov (United States)

    Mendoza, Jeff; Weir, Don

    2012-01-01

    This final report has been prepared by Honeywell Aerospace, Phoenix, Arizona, a unit of Honeywell International, Inc., documenting work performed during the period September 2004 through November 2005 for the National Aeronautics and Space Administration (NASA) Glenn Research Center, Cleveland, Ohio, under the Revolutionary Aero-Space Engine Research (RASER) Program, Contract No. NAS3- 01136, Task Order 6, Noise Measurements of the VAIIPR Fan. The NASA Task Manager was Dr. Joe Grady, NASA Glenn Research Center, Mail Code 60-6, Cleveland, Ohio 44135. The NASA Contract Officer was Mr. Albert Spence, NASA Glenn Research Center, Mail Code 60-6, Cleveland, Ohio 44135. This report focuses on the evaluation of internal fan noise as generated from various inflow disturbances based on measurements made from a circumferential array of sensors located near the fan and sensors upstream of a serpentine inlet.

  18. Characterization of the secondary flow in hexagonal ducts

    Science.gov (United States)

    Marin, O.; Vinuesa, R.; Obabko, A. V.; Schlatter, P.

    2016-12-01

    In this work we report the results of DNSs and LESs of the turbulent flow through hexagonal ducts at friction Reynolds numbers based on centerplane wall shear and duct half-height Reτ,c ≃ 180, 360, and 550. The evolution of the Fanning friction factor f with Re is in very good agreement with experimental measurements. A significant disagreement between the DNS and previous RANS simulations was found in the prediction of the in-plane velocity, and is explained through the inability of the RANS model to properly reproduce the secondary flow present in the hexagon. The kinetic energy of the secondary flow integrated over the cross-sectional area yz decreases with Re in the hexagon, whereas it remains constant with Re in square ducts at comparable Reynolds numbers. Close connection between the values of Reynolds stress u w ¯ on the horizontal wall close to the corner and the interaction of bursting events between the horizontal and inclined walls is found. This interaction leads to the formation of the secondary flow, and is less frequent in the hexagon as Re increases due to the 120∘ aperture of its vertex, whereas in the square duct the 90∘ corner leads to the same level of interaction with increasing Re. Analysis of turbulence statistics at the centerplane and the azimuthal variance of the mean flow and the fluctuations shows a close connection between hexagonal ducts and pipe flows, since the hexagon exhibits near-axisymmetric conditions up to a distance of around 0.15DH measured from its center. Spanwise distributions of wall-shear stress show that in square ducts the 90∘ corner sets the location of a high-speed streak at a distance zv+≃50 from it, whereas in hexagons the 120∘ aperture leads to a shorter distance of zv+≃38 . At these locations the root mean square of the wall-shear stresses exhibits an inflection point, which further shows the connections between the near-wall structures and the large-scale motions in the outer flow.

  19. Energy consumption characteristics of transports using the prop-fan concept

    Science.gov (United States)

    1976-01-01

    The fuel saving and economic potentials of the prop-fan high-speed propeller concept were evaluated for twin-engine commercial transport airplanes designed for 3333.6 km range, 180 passengers, and Mach 0.8 cruise. A fuel saving of 9.7% at the design range was estimated for a prop-fan airplane having wing-mounted engines, while a 5.8% saving was estimated for a design having the engines mounted on the aft body. The fuel savings and cost were found to be sensitive to the propeller noise level and to aerodynamic drag effects due to wing-slipstream interaction. Uncertainties in these effects could change the fuel savings as much as + or - 50%. A modest improvement in direct operating cost (DOC) was estimated for the wing-mounted prop-fan at current fuel prices. This improvement could become substantial in the event of further relative increases in the price of oil. The improvement in DOC requires the achievement of the nominal fuel saving and reductions in propeller and gearbox maintenance costs relative to current experience.

  20. Prototype Morphing Fan Nozzle Demonstrated

    Science.gov (United States)

    Lee, Ho-Jun; Song, Gang-Bing

    2004-01-01

    Ongoing research in NASA Glenn Research Center's Structural Mechanics and Dynamics Branch to develop smart materials technologies for aeropropulsion structural components has resulted in the design of the prototype morphing fan nozzle shown in the photograph. This prototype exploits the potential of smart materials to significantly improve the performance of existing aircraft engines by introducing new inherent capabilities for shape control, vibration damping, noise reduction, health monitoring, and flow manipulation. The novel design employs two different smart materials, a shape-memory alloy and magnetorheological fluids, to reduce the nozzle area by up to 30 percent. The prototype of the variable-area fan nozzle implements an overlapping spring leaf assembly to simplify the initial design and to provide ease of structural control. A single bundle of shape memory alloy wire actuators is used to reduce the nozzle geometry. The nozzle is subsequently held in the reduced-area configuration by using magnetorheological fluid brakes. This prototype uses the inherent advantages of shape memory alloys in providing large induced strains and of magnetorheological fluids in generating large resistive forces. In addition, the spring leaf design also functions as a return spring, once the magnetorheological fluid brakes are released, to help force the shape memory alloy wires to return to their original position. A computerized real-time control system uses the derivative-gain and proportional-gain algorithms to operate the system. This design represents a novel approach to the active control of high-bypass-ratio turbofan engines. Researchers have estimated that such engines will reduce thrust specific fuel consumption by 9 percent over that of fixed-geometry fan nozzles. This research was conducted under a cooperative agreement (NCC3-839) at the University of Akron.

  1. ECOLO-HOUSE in the snowy town. Study of the ventilating function what the heat collecting system of the air duct utilizing attic has; Yukiguni ECOLO-HOUSE. Kison kaoku no yaneura wo riyoshita duct shunetsu system

    Energy Technology Data Exchange (ETDEWEB)

    Umemiya, H; Hirosawa, K [Yamagata University, Yamagata (Japan)

    1996-10-27

    Described in this paper is an air duct heat collecting system, forming a link in the chain of natural energy utilization, in an attic of a house actually in presence. When a sirocco fan (blowing air from an indoor induction duct into the room) at the base of the highblocked floor is turned, air is sucked through an air intake under the eaves into a heat collecting duct (constructed utilizing the tilt roof and rafter). Heat from the roof warmed by sunshine is absorbed by air in the heat collecting duct and is fed to the highblocked floor structure through a heat collecting room and the induction duct. This system functions quite effectively as a ventilating device. Dew condensation on the walls and floor and musty smell have been eliminated. This system is good enough as a heater even on chilly days in early spring when there is sunshine. In the time zone with the sun shining, the system collects 4{times}10{sup 4}kJ per day, exhibiting a heat collecting efficiency of 4%. The heat collecting duct was analyzed for thermal environment, and the heat flux of the collected heat was determined as Qk(W/m{sup 2}=0.1{times}I-1.3{Theta}d-{Theta}a). In this equation, I is the quantity of insolation (W/m{sup 2}), {Theta}d is the temperature in the heat collecting duct, and {Theta}a is the free air temperature. 2 refs., 8 figs.

  2. An investigation of FLUENT's fan model including the effect of swirl velocity

    International Nuclear Information System (INIS)

    El Saheli, A.; Barron, R.M.

    2002-01-01

    The purpose of this paper is to investigate and discuss the reliability of simplified models for the computational fluid dynamics (CFD) simulation of air flow through automotive engine cooling fans. One of the most widely used simplified fan models in industry is a variant of the actuator disk model which is available in most commercial CFD software, such as FLUENT. In this model, the fan is replaced by an infinitely thin surface on which pressure rise across the fan is specified as a polynomial function of normal velocity or flow rate. The advantages of this model are that it is simple, it accurately predicts the pressure rise through the fan and the axial velocity, and it is robust

  3. Computational Aerodynamic Simulations of a 1215 ft/sec Tip Speed Transonic Fan System Model for Acoustic Methods Assessment and Development

    Science.gov (United States)

    Tweedt, Daniel L.

    2014-01-01

    Computational Aerodynamic simulations of a 1215 ft/sec tip speed transonic fan system were performed at five different operating points on the fan operating line, in order to provide detailed internal flow field information for use with fan acoustic prediction methods presently being developed, assessed and validated. The fan system is a sub-scale, low-noise research fan/nacelle model that has undergone extensive experimental testing in the 9- by 15-foot Low Speed Wind Tunnel at the NASA Glenn Research Center. Details of the fan geometry, the computational fluid dynamics methods, the computational grids, and various computational parameters relevant to the numerical simulations are discussed. Flow field results for three of the five operating points simulated are presented in order to provide a representative look at the computed solutions. Each of the five fan aerodynamic simulations involved the entire fan system, which for this model did not include a split flow path with core and bypass ducts. As a result, it was only necessary to adjust fan rotational speed in order to set the fan operating point, leading to operating points that lie on a fan operating line and making mass flow rate a fully dependent parameter. The resulting mass flow rates are in good agreement with measurement values. Computed blade row flow fields at all fan operating points are, in general, aerodynamically healthy. Rotor blade and fan exit guide vane flow characteristics are good, including incidence and deviation angles, chordwise static pressure distributions, blade surface boundary layers, secondary flow structures, and blade wakes. Examination of the flow fields at all operating conditions reveals no excessive boundary layer separations or related secondary-flow problems.

  4. Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers

    Energy Technology Data Exchange (ETDEWEB)

    Nassif, Nabil [Florida Solar Energy Center, A Research Institute of the University of Center Florida, 1679 Clearlake Road, Cocoa, FL 32922 (United States)

    2010-07-15

    HVAC systems and associated equipment consume a relatively large fraction of total building energy consumption, a significant portion of which is attributed to fan operation. The operation of economizer dampers when installed can cause high energy consumption in fans if they are not functioning in proper and optimal manner. This will mainly be due to the potential high pressure drops through those dampers and associated high total pressures that should be developed by supply and/or return fans. It is then necessary to ensure that a proper strategy to operate optimally the economizer dampers is implemented with minimum fan energy use. The paper examines several operation strategies of the economizer dampers and investigates their effects on the performance of both the supply and return fans in HVAC system. It also discusses a new operating strategy for economizer dampers that can lead to lower fan energy use. The strategies are evaluated by simulations for a typically existing HVAC system. Several factors such as the building locations, system characteristics, resistance in the duct where the dampers are installed, supply air temperature and economizer control, and minimum ventilation requirements are also considered during the evaluations. The results show that the way of the economizer dampers been controlled has a significant effect on fan performance and its energy use. The proposed strategy if properly implemented can provide fan energy saving in the range of 5-30%, depending mainly on the number of hours when the system operates in the free cooling mode, damper characteristics, and minimum outdoor air. (author)

  5. The impact of duct-to-duct interaction on the hex duct dilation

    International Nuclear Information System (INIS)

    Lee, M.J.; Chang, L.K.; Lahm, C.E.; Porter, D.L.

    1992-01-01

    Dilation of the hex duct is an important factor in the operational lifetime of fuel subassemblies in liquid metal fast reactors. It is caused primarily by the irradiation-enhanced creep and void swelling of the hex duct material. Excessive dilation may jeopardize subassembly removal from the core or cause a subassembly storage problem where the grid size of the storage basket is limited. Dilation of the hex duct in Experimental Breeder Reactor II (EBR-II) limits useful lifetime because of these storage basket limitations. It is, therefore, important to understand the hex duct dilation behavior to guide the design and in-core management of fuel subassemblies in a way that excessive duct deformation can be avoided. To investigate the dilation phenomena, finite-element models of the hex duct have been developed. The inelastic analyses were performed using the structural analysis code, ANSYS. Both Type 316 and D9 austenitic stainless steel ducts are considered. The calculated dilations are in good agreement with profilometry measurements made after irradiation. The analysis indicates that subassembly interaction is an important parameter in addition to neutron fluence and temperature in determining hex duct dilation. 5 refs

  6. Fan interaction noise reduction using a wake generator: experiments and computational aeroacoustics

    Science.gov (United States)

    Polacsek, C.; Desbois-Lavergne, F.

    2003-08-01

    A control grid (wake generator) aimed at reducing rotor-stator interaction modes in fan engines when mounted upstream of the rotor has been studied here. This device complements other active noise control systems currently proposed. The compressor model of the instrumented ONERA CERF-rig is used to simulate suitable conditions. The design of the grid is drafted out using semi-empirical models for wake and potential flow, and experimentally achieved. Cylindrical rods are able to generate a spinning mode of the same order and similar level as the interaction mode. Mounting the rods on a rotating ring allows for adjusting the phase of the control mode so that an 8 dB sound pressure level (SPL) reduction at the blade passing frequency is achieved when the two modes are out of phase. Experimental results are assessed by a numerical approach using computational fluid dynamics (CFD). A Reynolds averaged Navier-Stokes 2-D solver, developed at ONERA, is used to provide the unsteady force components on blades and vanes required for acoustics. The loading noise source term of the Ffowcs Williams and Hawkings equation is used to model the interaction noise between the sources, and an original coupling to a boundary element method (BEM) code is realized to take account of the inlet geometry effects on acoustic in-duct propagation. Calculations using the classical analytical the Green function of an infinite annular duct are also addressed. Simple formulations written in the frequency domain and expanded into modes are addressed and used to compute an in-duct interaction mode and to compare with the noise reduction obtained during the tests. A fairly good agreement between predicted and measured SPL is found when the inlet geometry effects are part of the solution (by coupling with the BEM). Furthermore, computed aerodynamic penalties due to the rods are found to be negligible. These results partly validate the computation chain and highlight the potential of the wake generator

  7. Structural Analysis and Optimization of a Composite Fan Blade for Future Aircraft Engine

    Science.gov (United States)

    Coroneos, Rula M.; Gorla, Rama Subba Reddy

    2012-09-01

    This paper addresses the structural analysis and optimization of a composite sandwich ply lay-up of a NASA baseline solid metallic fan blade comparable to a future Boeing 737 MAX aircraft engine. Sandwich construction with a polymer matrix composite face sheet and honeycomb aluminum core replaces the original baseline solid metallic fan model made of Titanium. The focus of this work is to design the sandwich composite blade with the optimum number of plies for the face sheet that will withstand the combined pressure and centrifugal loads while the constraints are satisfied and the baseline aerodynamic and geometric parameters are maintained. To satisfy the requirements a sandwich construction for the blade is proposed with composite face sheets and a weak core made of honeycomb aluminum material. For aerodynamic considerations, the thickness of the core is optimized where as the overall blade thickness is held fixed in order not to alter the original airfoil geometry. Weight reduction is taken as the objective function by varying the core thickness of the blade within specified upper and lower bounds. Constraints are imposed on radial displacement limitations and ply failure strength. From the optimum design, the minimum number of plies, which will not fail, is back-calculated. The ply lay-up of the blade is adjusted from the calculated number of plies and final structural analysis is performed. Analyses were carried out by utilizing the OpenMDAO Framework, developed at NASA Glenn Research Center combining optimization with structural assessment.

  8. Hybrid Wing Body Shielding Studies Using an Ultrasonic Configurable Fan Artificial Noise Source Generating Simple Modes

    Science.gov (United States)

    Sutliff, Daniel, L.; Brown, Clifford, A.; Walker, Bruce, E.

    2012-01-01

    An Ultrasonic Configurable Fan Artificial Noise Source (UCFANS) was designed, built, and tested in support of the Langley Research Center s 14- by 22-Foot wind tunnel test of the Hybrid Wing Body (HWB) full three-dimensional 5.8 percent scale model. The UCFANS is a 5.8 percent rapid prototype scale model of a high-bypass turbofan engine that can generate the tonal signature of candidate engines using artificial sources (no flow). The purpose of the test was to provide an estimate of the acoustic shielding benefits possible from mounting the engine on the upper surface of an HWB aircraft and to provide a database for shielding code validation. A range of frequencies, and a parametric study of modes were generated from exhaust and inlet nacelle configurations. Radiated acoustic data were acquired from a traversing linear array of 13 microphones, spanning 36 in. Two planes perpendicular to the axis of the nacelle (in its 0 orientation) and three planes parallel were acquired from the array sweep. In each plane the linear array traversed five sweeps, for a total span of 160 in. acquired. The resolution of the sweep is variable, so that points closer to the model are taken at a higher resolution. Contour plots of Sound Pressure Level, and integrated Power Levels are presented in this paper; as well as the in-duct modal structure.

  9. Depressurization test on hot gas duct

    International Nuclear Information System (INIS)

    Tanihira, Masanori; Kunitomi; Kazuhiko; Inagaki, Yoshiyuki; Miyamoto, Yoshiaki; Sato, Yutaka.

    1989-05-01

    To study the integrity of internal structures and the characteristics in a hot gas duct under the rapid depressurization accident, depressurization tests have been carried out using a test apparatus installed the hot gas duct with the same size and the same structures as that of the High Temperature Engineering Test Reactor (HTTR). The tests have been performed with three parameters: depressurization rate (0.14-3.08 MPa/s) determined by orifice diameter, area of the open space at the slide joint (11.9-2036 mm 2 ), and initial pressure (1.0-4.0 MPa) filled up in a pressure vessel, by using nitrogen gas and helium gas. The maximum pressure difference applied on the internal structures of the hot gas duct was 2.69 MPa on the liner tube and 0.45 MPa on the separating plate. After all tests were completed, the hot gas duct which was used in the tests was disassembled. Inspection revealed that there were no failure and no deformation on the internal structures such as separating plates, insulation layers, a liner tube and a pressure tube. (author)

  10. Numerical Investigation of the Influence of the Input Air Irregularity on the Performance of Turbofan Jet Engine

    Science.gov (United States)

    Novikova, Y.; Zubanov, V.

    2018-01-01

    The article describes the numerical investigation of the input air irregularity influence of turbofan engine on its characteristics. The investigated fan has a wide-blade, an inlet diameter about 2 meters, a pressure ratio about 1.6 and the bypass ratio about 4.8. The flow irregularity was simulated by the flap input in the fan inlet channel. Input of flap was carried out by an amount of 10 to 22,5% of the input channel diameter with increments of 2,5%. A nonlinear harmonic analysis (NLH-analysis) of NUMECA Fine/Turbo software was used to study the flow irregularity. The behavior of the calculated LPC characteristics repeats the experiment behavior, but there is a quantitative difference: the calculated efficiency and pressure ratio of booster consistent with the experimental data within 3% and 2% respectively, the calculated efficiency and pressure ratio of fan duct - within 4% and 2.5% respectively. An increasing the level of air irregularity in the input stage of the fan reduces the calculated mass flow, maximum pressure ratio and efficiency. With the value of flap input 12.5%, reducing the maximum air flow is 1.44%, lowering the maximum pressure ratio is 2.6%, efficiency decreasing is 3.1%.

  11. Data analysis of ship ventilation ducts based on CATIA V6

    Directory of Open Access Journals (Sweden)

    LU Yongjin

    2017-03-01

    Full Text Available In order to research on CATIA V6 ship duct design and related data,combined with a practical engineering background,a three-dimensional design method for the CATIA V6 ventilation system is exhibited,and the catalog composition of duct fittings and duct lofting process are presented. Meanwhile, revolving around the system design modules,the module processing objects and data storage location are analyzed in order to determine the object of study. And on this basis,the definition and specific content of the engineering technological tables are illustrated in detail;specifically,the contents are extended. Moreover,in light of the three-dimensional model,further research into the underlying data structure of ventilation ducts is implemented. The relationships between the major technological tables are shown. The results of the study are not only beneficial for designers to grasp design technology,but also essential for software developers to secure theoretical guidance and technical support.

  12. Noise source identification for ducted fan systems

    OpenAIRE

    BENNETT, GARETH; FITZPATRICK, JOHN AIDAN

    2008-01-01

    PUBLISHED Coherence based source analysis techniques can be used to identify the contribution of combustion noise in the exhaust of a jet engine and hence enable the design of noise reduction devices. However, when the combustion noise propagates in a non-linear fashion the identified contribution using ordinary coherence methods will be inaccurate. In this paper, an analysis technique to enable the contribution of linear and non-linear mechanisms to the propagated sound ...

  13. D0 Cryo Ventilation Fan Controls and Monitoring

    International Nuclear Information System (INIS)

    Markley, D.

    1990-01-01

    This engineering note describes how exhaust fan 6 (EF-6) and exhaust fan 7 (EF-7) are controlled and monitored. Since these two fans are a vital link in the ODH safety system, they will be monitored, controlled and periodically operated by the programmable logic controller (PLC). If there should be a fault in the ventilation system, the PLC will print a warning message to the cryo control room printer and flash a descriptive warning on the ODH/ventilation graphics page. This fault is also logged to the Xpresslink graphics alarm page and to an alarm history hard disk file. The ventilation failure is also an input to the auto dialer which will continue it's automatic sequence until acknowledged. EF-6 delivers 13000 C.F.M. and is considered emergency ventilation. EF-7 delivers 4500 C.F.M. and will run 24 hrs a day. Both ventilation fans are located in an enclosed closet in the TRD gas room. Their ductwork, both inlets and outlets run along side the pipe chase, but are separated by an airtight wall. Their combination motor control starter cabinets are located in the TRD room in plain visible sight of the fans with the closet door open. The fans have signs that state they are automatically controlled and can energize at any time.

  14. Premix fuels study applicable to duct burner conditions for a variable cycle engine

    Science.gov (United States)

    Venkataramani, K. S.

    1978-01-01

    Emission levels and performance of a premixing Jet-A/air duct burner were measured at reference conditions representative of take-off and cruise for a variable cycle engine. In a parametric variation sequence of tests, data were obtained at inlet temperatures of 400, 500 and 600K at equivalence ratios varying from 0.9 to the lean stability limit. Ignition was achieved at all the reference conditions although the CO levels were very high. Significant nonuniformity across the combustor was observed for the emissions at the take-off condition. At a reference Mach number of 0.117 and an inlet temperature of 600K, corresponding to a simulated cruise condition, the NOx emission level was approximately 1 gm/kg-fuel.

  15. V/STOL Tandem Fan transition section model test. [in the Lewis Research Center 10-by-10 foot wind tunnel

    Science.gov (United States)

    Simpkin, W. E.

    1982-01-01

    An approximately 0.25 scale model of the transition section of a tandem fan variable cycle engine nacelle was tested in the NASA Lewis Research Center 10-by-10 foot wind tunnel. Two 12-inch, tip-turbine driven fans were used to simulate a tandem fan engine. Three testing modes simulated a V/STOL tandem fan airplane. Parallel mode has two separate propulsion streams for maximum low speed performance. A front inlet, fan, and downward vectorable nozzle forms one stream. An auxilliary top inlet provides air to the aft fan - supplying the core engine and aft vectorable nozzle. Front nozzle and top inlet closure, and removal of a blocker door separating the two streams configures the tandem fan for series mode operations as a typical aircraft propulsion system. Transition mode operation is formed by intermediate settings of the front nozzle, blocker door, and top inlet. Emphasis was on the total pressure recovery and flow distortion at the aft fan face. A range of fan flow rates were tested at tunnel airspeeds from 0 to 240 knots, and angles-of-attack from -10 to 40 deg for all three modes. In addition to the model variables for the three modes, model variants of the top inlet were tested in the parallel mode only. These lip variables were: aft lip boundary layer bleed holes, and Three position turning vane. Also a bellmouth extension of the top inlet side lips was tested in parallel mode.

  16. The Strength Analysis of CFM56 Engine Blade

    Directory of Open Access Journals (Sweden)

    Liu Zhenzhen

    2018-01-01

    Full Text Available Aero engine is a kind of thermodynamic machinery, which require have strict aerodynamic load, mechanical load and strong durability, its longevity depends largely on the life of its main components. In this paper, a series of studies are carried out on the strength of fan blades of CFM56 engine, which provide a reference value for improving the reliability of the engine. The finite element model of the engine fan is established by using CATIA’s finite element software.The centrifugal stress distribution of the fan at different speeds and the influence of torque on fans under different speeds are calculated respectively, and the static strength of the fan is checked.

  17. 14 CFR 27.903 - Engines.

    Science.gov (United States)

    2010-01-01

    ... failure; (ii) Each fan is located so that a failure will not jeopardize safety; or (iii) Each fan blade... shutdown of all engines, engine restart capability must be demonstrated throughout a flight envelope for...

  18. The underground main fan study at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    McDaniel, K.H.; Chmura, K.M.

    1996-01-01

    The Waste Isolation Pilot Plant (WIPP) performed a feasibility analysis for the purpose of either modifying, supplementing, or replacing its two main mine fans. The WIPP, located near Carlsbad, New Mexico, is a US Department of Energy (DOE) facility designed to demonstrate the permanent, safe disposal of US defense-generated transuranic waste in a deep bedded salt deposit. Since the centrifugal fans were installed in 1988, multiple operational and performance concerns have been identified. A comprehensive engineering study was conducted in 1995 to: (1) qualify and quantify operational concerns; (2) evaluate possible alternatives; and (3) recommend an optimum solution. Multiple system modification and/or replacement scenarios were evaluated with associated cost estimates developed. The study considered replacement with either centrifugal or axial fans. Multiple fan duties are required at the WIPP. Therefore, Variable Frequency Drives and Inlet Vane Controls (IVC) were investigated for centrifugal fans. In-flight adjustable blades were investigated for axial fans. The study indicated that replacing the existing system with two double-width, double-inlet centrifugal fans equipped with IVCs was the best choice. This alternative provided the most desirable combination of: (1) ensuring the required operational readiness, and (2) improving system performance. The WIPP is currently planning to replace the first fan in 1997

  19. Experiments on the Recovery of Waste Heat in Cooling Ducts, Special Report

    Science.gov (United States)

    Silverstein, Abe

    1939-01-01

    Tests have been conducted in the N.A.C.A. full-scale wind tunnel to investigate the partial recovery of the heat energy which is apparently wasted in the cooling of aircraft engines. The results indicate that if the radiator is located in an expanded duct, a part of the energy lost in cooling is recovered; however, the energy recovery is not of practical importance up to airplane speeds of 400 miles per hour. Throttling of the duct flow occurs with heated radiators and must be considered in designing the duct outlets from data obtained with cold radiators in the ducts.

  20. Dual Rotating Rake Measurements of Higher-Order Duct Modes: Validation Using Experimental and Numerical Data

    Science.gov (United States)

    Dahl, Milo D.; Hixon, Duane R.; Sutliff, Daniel L.

    2018-01-01

    A rotating rake mode measurement system was designed to measure acoustic duct modes generated by a fan stage. After analysis of the measured data, the mode coefficient amplitudes and phases were quantified. Early studies using this system found that mode power levels computed from rotating rake measured data would agree with the far-field power levels. However, this agreement required that the sound from the noise sources within the duct propagated outward from the duct exit without reflection and previous studies suggested conditions could exist where significant reflections could occur. This paper shows that mounting a second rake to the rotating system, with an offset in both the axial and the azimuthal directions, measures the data necessary to determine the modes propagating in both directions within a duct. The rotating rake data analysis technique was extended to include the data measured by the second rake. The analysis resulted in a set of circumferential mode coefficients at each of the two rake microphone locations. Radial basis functions were then least-squares fit to this data to obtain the radial mode coefficients for the modes propagating in both directions within the duct while accounting for the presence of evanescent modes. The validation of the dual-rotating-rake measurements was conducted using data from a combination of experiments and numerical calculations to compute reflection coefficients and other mode coefficient ratios. Compared to results from analytical and numerical computations, the results from dual-rotating-rake measured data followed the expected trends when frequency, mode number, and duct termination geometry were changed.

  1. Computerized systems analysis and optimization of aircraft engine performance, weight, and life cycle costs

    Science.gov (United States)

    Fishbach, L. H.

    1979-01-01

    The computational techniques utilized to determine the optimum propulsion systems for future aircraft applications and to identify system tradeoffs and technology requirements are described. The characteristics and use of the following computer codes are discussed: (1) NNEP - a very general cycle analysis code that can assemble an arbitrary matrix fans, turbines, ducts, shafts, etc., into a complete gas turbine engine and compute on- and off-design thermodynamic performance; (2) WATE - a preliminary design procedure for calculating engine weight using the component characteristics determined by NNEP; (3) POD DRG - a table look-up program to calculate wave and friction drag of nacelles; (4) LIFCYC - a computer code developed to calculate life cycle costs of engines based on the output from WATE; and (5) INSTAL - a computer code developed to calculate installation effects, inlet performance and inlet weight. Examples are given to illustrate how these computer techniques can be applied to analyze and optimize propulsion system fuel consumption, weight, and cost for representative types of aircraft and missions.

  2. The Effect of Bypass Nozzle Exit Area on Fan Aerodynamic Performance and Noise in a Model Turbofan Simulator

    Science.gov (United States)

    Hughes, Christopher E.; Podboy, Gary, G.; Woodward, Richard P.; Jeracki, Robert, J.

    2013-01-01

    The design of effective new technologies to reduce aircraft propulsion noise is dependent on identifying and understanding the noise sources and noise generation mechanisms in the modern turbofan engine, as well as determining their contribution to the overall aircraft noise signature. Therefore, a comprehensive aeroacoustic wind tunnel test program was conducted called the Fan Broadband Source Diagnostic Test as part of the NASA Quiet Aircraft Technology program. The test was performed in the anechoic NASA Glenn 9- by 15-Foot Low Speed Wind Tunnel using a 1/5 scale model turbofan simulator which represented a current generation, medium pressure ratio, high bypass turbofan aircraft engine. The investigation focused on simulating in model scale only the bypass section of the turbofan engine. The test objectives were to: identify the noise sources within the model and determine their noise level; investigate several component design technologies by determining their impact on the aerodynamic and acoustic performance of the fan stage; and conduct detailed flow diagnostics within the fan flow field to characterize the physics of the noise generation mechanisms in a turbofan model. This report discusses results obtained for one aspect of the Source Diagnostic Test that investigated the effect of the bypass or fan nozzle exit area on the bypass stage aerodynamic performance, specifically the fan and outlet guide vanes or stators, as well as the farfield acoustic noise level. The aerodynamic performance, farfield acoustics, and Laser Doppler Velocimeter flow diagnostic results are presented for the fan and four different fixed-area bypass nozzle configurations. The nozzles simulated fixed engine operating lines and encompassed the fan stage operating envelope from near stall to cruise. One nozzle was selected as a baseline reference, representing the nozzle area which would achieve the design point operating conditions and fan stage performance. The total area change from

  3. Thermal performance test of the hot gas ducts of HENDEL

    International Nuclear Information System (INIS)

    Hishida, M.; Kunitomi, K.; Ioka, I.; Umenishi, K.; Tanaka, T.; Shimomura, H.; Sanokawa, K.

    1984-01-01

    A hot gas duct provided with internal thermal insulation is to be used for high-temperature gas-cooled reactors (HTGR). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of a hot gas duct have been conducted. The present report deals with the results of the thermal performance of the single tube type hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL). Uniform temperature and heat flux distribution at the surface of the duct were observed, the experimental correlations being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of the co-axial hot gas duct was evaluated and no hot spot was detected. These results would be very valuable for the design and development of HTGR. (orig.)

  4. Advance Noise Control Fan II: Test Rig Fan Risk Management Study

    Science.gov (United States)

    Lucero, John

    2013-01-01

    Since 1995 the Advanced Noise Control Fan (ANCF) has significantly contributed to the advancement of the understanding of the physics of fan tonal noise generation. The 9'x15' WT has successfully tested multiple high speed fan designs over the last several decades. This advanced several tone noise reduction concepts to higher TRL and the validation of fan tone noise prediction codes.

  5. Multi-objective optimization design and experimental investigation of centrifugal fan performance

    Science.gov (United States)

    Zhang, Lei; Wang, Songling; Hu, Chenxing; Zhang, Qian

    2013-11-01

    Current studies of fan performance optimization mainly focus on two aspects: one is to improve the blade profile, and another is only to consider the influence of single impeller structural parameter on fan performance. However, there are few studies on the comprehensive effect of the key parameters such as blade number, exit stagger angle of blade and the impeller outlet width on the fan performance. The G4-73 backward centrifugal fan widely used in power plants is selected as the research object. Based on orthogonal design and BP neural network, a model for predicting the centrifugal fan performance parameters is established, and the maximum relative errors of the total pressure and efficiency are 0.974% and 0.333%, respectively. Multi-objective optimization of total pressure and efficiency of the fan is conducted with genetic algorithm, and the optimum combination of impeller structural parameters is proposed. The optimized parameters of blade number, exit stagger angle of blade and the impeller outlet width are seperately 14, 43.9°, and 21 cm. The experiments on centrifugal fan performance and noise are conducted before and after the installation of the new impeller. The experimental results show that with the new impeller, the total pressure of fan increases significantly in total range of the flow rate, and the fan efficiency is improved when the relative flow is above 75%, also the high efficiency area is broadened. Additionally, in 65% -100% relative flow, the fan noise is reduced. Under the design operating condition, total pressure and efficiency of the fan are improved by 6.91% and 0.5%, respectively. This research sheds light on the considering of comprehensive effect of impeller structrual parameters on fan performance, and a new impeller can be designed to satisfy the engineering demand such as energy-saving, noise reduction or solving air pressure insufficiency for power plants.

  6. Ultra light weight jet engine JR100; Chokeiryo jet engine JR100

    Energy Technology Data Exchange (ETDEWEB)

    Matsuki, M. [Nippon Institute of Technology, Saitama (Japan)

    1999-03-20

    As a part of the jet lift V/STOL research by National Aerospace Laboratory, a study of trial manufacture of ultra light weight jet engine JR 100 started in FY 1964. The study was aimed at obtaining a lift engine for VTOL and founding the base for the future jet lift VTOL, and at taking in the results of the jet engine element study accumulated so far and manufacturing an advanced engine. Decided on the use of domestic materials for JR 100, the materials to be used are almost iron-based ones. Through the efforts for weight reduction in structure and processing, a thrust/weight ratio of 10 was realized. At the same time, the production/processing of light weight materials such as titanium alloys was proceeded with, and by adopting the materials to JR 200 system, a thrust/weight ratio of 15 was realized. Together with these, for the purpose of reducing the fuel consumption rate, studies started on fan for lift fan engine and high temperature turbine (an inlet temperature of 1250 degrees C was achieved), to get low noise/high efficiency fan. By the research results, the basis for jet lift VTOL was established, and it became the basis for the development of turbo fan engine FJR 710. (NEDO)

  7. Hybrid Wing Body Shielding Studies Using an Ultrasonic Configurable Fan Artificial Noise Source Generating Typical Turbofan Modes

    Science.gov (United States)

    Sutliff, Daniel l.; Brown, Clifford A.; Walker, Bruce E.

    2014-01-01

    An Ultrasonic Configurable Fan Artificial Noise Source (UCFANS) was designed, built, and tested in support of the NASA Langley Research Center's 14- by 22-ft wind tunnel test of the Hybrid Wing Body (HWB) full 3-D 5.8 percent scale model. The UCFANS is a 5.8 percent rapid prototype scale model of a high-bypass turbofan engine that can generate the tonal signature of proposed engines using artificial sources (no flow). The purpose of the test was to provide an estimate of the acoustic shielding benefits possible from mounting the engine on the upper surface of an HWB aircraft using the projected signature of the engine currently proposed for the HWB. The modal structures at the rating points were generated from inlet and exhaust nacelle configurations--a flat plate model was used as the shielding surface and vertical control surfaces with correct plan form shapes were also tested to determine their additional impact on shielding. Radiated acoustic data were acquired from a traversing linear array of 13 microphones, spanning 36 in. Two planes perpendicular, and two planes parallel, to the axis of the nacelle were acquired from the array sweep. In each plane the linear array traversed four sweeps, for a total span of 168 in. acquired. The resolution of the sweep is variable, so that points closer to the model are taken at a higher resolution. Contour plots of Sound Pressure Levels, and integrated Power Levels, from nacelle alone and shielded configurations are presented in this paper; as well as the in-duct mode power levels

  8. Hybrid Wing Body Shielding Studies Using an Ultrasonic Configurable Fan Artificial Noise Source Generating Typical Turbofan Modes

    Science.gov (United States)

    Sutliff, Daniel L.; Brown, Cliff; Walker, Bruce E.

    2014-01-01

    An Ultrasonic Configurable Fan Artificial Noise Source (UCFANS) was designed, built, and tested in support of the NASA Langley Research Center's 14x22 wind tunnel test of the Hybrid Wing Body (HWB) full 3-D 5.8% scale model. The UCFANS is a 5.8% rapid prototype scale model of a high-bypass turbofan engine that can generate the tonal signature of proposed engines using artificial sources (no flow). The purpose of the test was to provide an estimate of the acoustic shielding benefits possible from mounting the engine on the upper surface of an HWB aircraft using the projected signature of the engine currently proposed for the HWB. The modal structures at the rating points were generated from inlet and exhaust nacelle configurations - a flat plate model was used as the shielding surface and vertical control surfaces with correct plan form shapes were also tested to determine their additional impact on shielding. Radiated acoustic data were acquired from a traversing linear array of 13 microphones, spanning 36 inches. Two planes perpendicular, and two planes parallel, to the axis of the nacelle were acquired from the array sweep. In each plane the linear array traversed 4 sweeps, for a total span of 168 inches acquired. The resolution of the sweep is variable, so that points closer to the model are taken at a higher resolution. Contour plots of Sound Pressure Levels, and integrated Power Levels, from nacelle alone and shielded configurations are presented in this paper; as well as the in-duct mode power levels.

  9. Bile Duct Exploration

    Science.gov (United States)

    ... Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Bile Duct Exploration Common bile duct exploration is a ... Test Details Results and Follow-Up What is bile, and what is bile duct exploration? Bile is ...

  10. FOREWORD: 6th International Conference on Pumps and Fans with Compressors and Wind Turbines (ICPF2013)

    Science.gov (United States)

    Wu, Yulin; Wang, Zhengwei; Yuan, Shouqi; Shi, Weidong; Liu, Shuhong; Luo, Xingqi; Wang, Fujun

    2013-12-01

    The 6th International Conference on Pumps and Fans with Compressors and Wind Turbines (ICPF 2013) was held in Beijing, China, 19-22 September 2013, which was jointly organized by Tsinghua University and Jiangsu University. The co-organizers were Zhejiang University, Zhejiang Sci-Tech University, The State Key Laboratory of Hydroscience and Engineering, The State Key Laboratory of Automotive Safety and Energy and Beijing International Science and Technology Cooperation Base for CO2 Utilization and Reduction. The sponsor of the conference was Concepts NREC. The First International Conference on Pumps and Systems (May 1992), the Second International Conference on Pumps and Fans (October 1995), the Third International Conference on Pumps and Fans (October 1998), and the Fourth International Conference on Pumps and Fans (26-29 August 2002) were all held in Beijing and were organized by the late famous Chinese professor on fluid machinery and engineering, Professor Zuyan Mei of Tsinghua University. The conference was interrupted by the death of Professor Mei in 2003. In order to commemorate Professor Mei, the organizing committee of ICPF decided to continue organizing the conference series. The Fifth Conference on Pumps and Systems (2010 ICPF) took place in Hangzhou, Zhejiang Province, China, 18-21 October 2010, and it was jointly organized by Zhejiang University and Tsinghua University. With the development of renewable energy and new energy in China and in the world, some small types of compressor and some types of pump, as well as wind turbines are developing very fast; therefore the ICPF2013 conference included compressors and wind turbines. The theme of the conference was the application of renewable energy of pumps, compressors, fans and blowers. The content of the conference was the basic study, design and experimental study of compressors, fans, blowers and pumps; the CFD application on pumps and fans, their transient behavior, unsteady flows and multi-phase flow

  11. Two novel genes, fanA and fanB, involved in the biogenesis of K99 fimbriae.

    Science.gov (United States)

    Roosendaal, E; Boots, M; de Graaf, F K

    1987-08-11

    The nucleotide sequence of the region located transcriptionally upstream of the K99 fimbrial subunit gene (fanC) was determined. Several putative transcription signals and two open reading frames, designated fanA and fanB, became apparent. Frameshift mutations in fanA and fanB reduced K99 fimbriae expression 8-fold and 16-fold, respectively. Complementation of the mutants in trans restored the K99 expression to about 75% of the wild type level, indicating that fanA and fanB code for transacting polypeptides involved in the biogenesis of K99 fimbriae. The fanA and fanB gene products FanA and FanB were not detectable in minicell preparations, indicating that both polypeptides are synthesized in very small amounts. However, in an in vitro DNA directed translation system FanA and FanB could be identified. The deduced amino acid sequences of FanA and FanB showed that both polypeptides contain no signal peptides, indicating a cytoplasmic location. Furthermore, the polypeptides are very hydrophilic, mainly basic, and exhibit remarkable homology to each other and to a regulatory protein (papB) encoded by the pap-operon (1). Some of these features are characteristics of nucleic acid binding proteins, which suggests that FanA and FanB have a regulatory function in the synthesis of FanC and the auxiliary polypeptides FanD-H.

  12. WHO ARE FANS OF FACEBOOK FAN PAGES? AN ELECTRONIC WORD-OF-MOUTH COMMUNICATION PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Xiao Hu

    2014-12-01

    Full Text Available Given its great business value and popularity, Facebook fan pages have attracted more and more attention in both industry and academia. Fans of Facebook fan pages play an important role in electronic word-of-mouth (eWOM communication. This study focused on the population of fans on Facebook fan pages and examined the differences between fans and non-fans in terms of demographics, social network sites (SNS use, Internet use, and online shopping behaviors. The results indicated that fans used SNS more frequently than non-fans. Additionally, from the eWOM perspective, the researchers moderated product types in the model of people’s word-of-mouth (WOM preferences and found that people had different preferences for eWOM and traditional WOM for different products. Traditional WOM is still the most important source of information for people when shopping online.

  13. Contrasting morphodynamics in alluvial fans and fan deltas: effect of the downstream boundary

    NARCIS (Netherlands)

    Dijk, M. van; Kleinhans, M.G.; Postma, G.; Kraal, E.

    2012-01-01

    Alluvial fans and fan deltas can, in principle, have exactly the same upstream conditions, but fan deltas by definition have ponding water at their downstream boundary. This ponding creates effects on the autogenic behaviour of fan deltas, such as backwater adaptation, mouth bars and backward

  14. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    Science.gov (United States)

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.

  15. Piezoelectric Vibration Damping Study for Rotating Composite Fan Blades

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Choi, Benjamin B.; Provenza, Andrew J.; Kray, Nicholas

    2012-01-01

    Resonant vibrations of aircraft engine blades cause blade fatigue problems in engines, which can lead to thicker and aerodynamically lower performing blade designs, increasing engine weight, fuel burn, and maintenance costs. In order to mitigate undesirable blade vibration levels, active piezoelectric vibration control has been investigated, potentially enabling thinner blade designs for higher performing blades and minimizing blade fatigue problems. While the piezoelectric damping idea has been investigated by other researchers over the years, very little study has been done including rotational effects. The present study attempts to fill this void. The particular objectives of this study were: (a) to develop and analyze a multiphysics piezoelectric finite element composite blade model for harmonic forced vibration response analysis coupled with a tuned RLC circuit for rotating engine blade conditions, (b) to validate a numerical model with experimental test data, and (c) to achieve a cost-effective numerical modeling capability which enables simulation of rotating blades within the NASA Glenn Research Center (GRC) Dynamic Spin Rig Facility. A numerical and experimental study for rotating piezoelectric composite subscale fan blades was performed. It was also proved that the proposed numerical method is feasible and effective when applied to the rotating blade base excitation model. The experimental test and multiphysics finite element modeling technique described in this paper show that piezoelectric vibration damping can significantly reduce vibrations of aircraft engine composite fan blades.

  16. Lift/cruise fan V/STOL technology aircraft design definition study. Volume 1: Technology flight vehicle definition

    Science.gov (United States)

    Obrien, W. J.

    1976-01-01

    Concept design is presented for two types of lift/cruise fan technology V/STOL aircraft, turbotip fans and the other using mechanically driven fans. The turbotip research technology aircraft reflects maximum usage of existing airframe components. The propulsion system consists of three turbotip fans pneumatically interconnected to three gas generators. Thrust modulation is accomplished by use of energy transfer and control system and thrust reduction modulation. This system can also be operated in the two engine/three fan mode. The mechanical RTA is virtually identical to the turbotip RTA with the exceptions that a different propulsion system and aft fuselage/tail are used. Both aircraft meet or exceed all of the mission performance guidelines and reflect a low cost, low risk approach.

  17. 75 FR 79952 - Airworthiness Directives; DASSAULT AVIATION Model Falcon 10 Airplanes; Model FAN JET FALCON, FAN...

    Science.gov (United States)

    2010-12-21

    ... Airworthiness Directives; DASSAULT AVIATION Model Falcon 10 Airplanes; Model FAN JET FALCON, FAN JET FALCON.... (1) DASSAULT AVIATION Model Falcon 10 airplanes, Model FAN JET FALCON, FAN JET FALCON SERIES C, D, E... airplanes Inspection threshold (whichever occurs later) Inspection interval Model FAN JET FALCON, FAN JET...

  18. A non-regular Groebner fan

    OpenAIRE

    Jensen, Anders N.

    2005-01-01

    The Groebner fan of an ideal $I\\subset k[x_1,...,x_n]$, defined by Mora and Robbiano, is a complex of polyhedral cones in $R^n$. The maximal cones of the fan are in bijection with the distinct monomial initial ideals of $I$ as the term order varies. If $I$ is homogeneous the Groebner fan is complete and is the normal fan of the state polytope of $I$. In general the Groebner fan is not complete and therefore not the normal fan of a polytope. We may ask if the restricted Groebner fan, a subdivi...

  19. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...

  20. The Role of Flow Diagnostic Techniques in Fan and Open Rotor Noise Modeling

    Science.gov (United States)

    Envia, Edmane

    2016-01-01

    A principal source of turbomachinery noise is the interaction of the rotating and stationary blade rows with the perturbations in the airstream through the engine. As such, a lot of research has been devoted to the study of the turbomachinery noise generation mechanisms. This is particularly true of fan and open rotors, both of which are the major contributors to the overall noise output of modern aircraft engines. Much of the research in fan and open rotor noise has been focused on developing theoretical models for predicting their noise characteristics. These models, which run the gamut from the semi-empirical to fully computational ones, are, in one form or another, informed by the description of the unsteady flow-field in which the propulsors (i.e., the fan and open rotors) operate. Not surprisingly, the fidelity of the theoretical models is dependent, to a large extent, on capturing the nuances of the unsteady flowfield that have a direct role in the noise generation process. As such, flow diagnostic techniques have proven to be indispensible in identifying the shortcoming of theoretical models and in helping to improve them. This presentation will provide a few examples of the role of flow diagnostic techniques in assessing the fidelity and robustness of the fan and open rotor noise prediction models.

  1. Technique for Selecting Optimum Fan Compression Ratio based on the Effective Power Plant Parameters

    Directory of Open Access Journals (Sweden)

    I. I. Kondrashov

    2016-01-01

    Full Text Available Nowadays, civilian aircrafts occupy the major share of global aviation industry market. As to medium and long - haul aircrafts, turbofans with separate exhaust streams are widely used. Here, fuel efficiency is the main criterion of this engine. The paper presents the research results of the mutual influence of fan pressure ratio and bypass ratio on the effective specific fuel consumption. Shows the increasing bypass ratio to be a rational step for reducing the fuel consumption. Also considers the basic features of engines with a high bypass ratio. Among the other working process parameters, fan pressure ratio and bypass ratio are the most relevant for consideration as they are the most structural variables at a given level of technical excellence. The paper presents the dependence of the nacelle drag coefficient on the engine bypass ratio. For computation were adopted the projected parameters of prospective turbofans to be used in the power plant of the 180-seat medium-haul aircraft. Computation of the engine cycle was performed in Mathcad using these data, with fan pressure ratio and bypass ratio being varied. The combustion chamber gas temperature, the overall pressure ratio and engine thrust remained constant. Pressure loss coefficients, the efficiency of the engine components and the amount of air taken for cooling also remained constant. The optimal parameters corresponding to the minimum effective specific fuel consumption were found as the result of computation. The paper gives recommendations for adjusting optimal parameters, depending on the considered external factors, such as weight of engine and required fuel reserve. The obtained data can be used to estimate parameters of future turbofan engines with high bypass ratio.

  2. Controls on alluvial fans morphology

    Science.gov (United States)

    Delorme, P.; Devauchelle, O.; Lajeunesse, E.; Barrier, L.; Métivier, F.

    2017-12-01

    Using laboratory experiments, we investigate the influence of water and sediment discharges on the morphology of an alluvial fan. In our flume, a single-thread laminar river deposits corundum sand (0.4 mm) into a conical fan. We record the fan progradation with top-view images, and measure its shape using the deformation of a Moiré pattern. The fan remains virtually self-affine as it grows, with a nearly constant slope. We find that, when the sediment discharge is small, the longitudinal slope of the fan remains close to that of a river at the threshold for sediment transport. A higher sediment discharge causes the fan's slope to depart from the threshold value. Due to the downstream decrease of the sediment load, this slope gets shallower towards the fan's toe. This mechanism generates a slightly concave fan profile. This suggests that the proximal slope of an alluvial fan could be a proxy for the sediment flux that feeds the fan.Finally, we discuss the applicability of these results to natural systems.

  3. Lift/cruise fan V/STOL technology aircraft design definition study. Volume 2: Propulsion transmission system design

    Science.gov (United States)

    Obrien, W. J.

    1976-01-01

    Two types of lift/cruise fan technology aircraft were conceptually designed. One aircraft used turbotip fans pneumatically interconnected to three gas generators, and the other aircraft used variable pitch fans mechanically interconnected to three turboshaft engines. The components of each propulsion transmission system were analyzed and designed to the depth necessary to determine areas of risk, development methods, performance, weights and costs. The types of materials and manufacturing processes were identified to show that the designs followed a low cost approach. The lift/cruise fan thrust vectoring hoods, which are applicable to either aircraft configuration, were also evaluated to assure a low cost/low risk approach.

  4. Transient simulation of coolant peak temperature due to prolonged fan and/or water pump operation after the vehicle is keyed-off

    Science.gov (United States)

    Pang, Suh Chyn; Masjuki, Haji Hassan; Kalam, Md. Abul; Hazrat, Md. Ali

    2014-01-01

    Automotive designers should design a robust engine cooling system which works well in both normal and severe driving conditions. When vehicles are keyed-off suddenly after some distance of hill-climbing driving, the coolant temperature tends to increase drastically. This is because heat soak in the engine could not be transferred away in a timely manner, as both the water pump and cooling fan stop working after the vehicle is keyed-off. In this research, we aimed to visualize the coolant temperature trend over time before and after the vehicles were keyed-off. In order to prevent coolant temperature from exceeding its boiling point and jeopardizing engine life, a numerical model was further tested with prolonged fan and/or water pump operation after keying-off. One dimensional thermal-fluid simulation was exploited to model the vehicle's cooling system. The behaviour of engine heat, air flow, and coolant flow over time were varied to observe the corresponding transient coolant temperatures. The robustness of this model was proven by validation with industry field test data. The numerical results provided sensible insights into the proposed solution. In short, prolonging fan operation for 500 s and prolonging both fan and water pump operation for 300 s could reduce coolant peak temperature efficiently. The physical implementation plan and benefits yielded from implementation of the electrical fan and electrical water pump are discussed.

  5. Evaluation of PEGIT duct connection system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Brenner, Douglas E.; Sherman, Max H.; Dickerhoff, Darryl J.

    2003-08-01

    Most air duct system components are assembled in the field and are mechanically fastened by sheet metal screws (for sheet metal-to-sheet metal) or by drawbands (for flex duct-to-sheet metal). Air sealing is separate from this mechanical fastening and is usually achieved using tape or mastic products after mechanical fastening. Field observations have shown that mechanical fastening rarely meets code or manufacturers requirements and that sealing procedures are similarly inconsistent. To address these problems, Proctor Engineering Group (PEG) is developing a system of joining ducts (called PEGIT) that combines the mechanical fastening and sealing into a single self-contained procedure. The PEGIT system uses a shaped flexible seal between specially designed sheet metal duct fittings to both seal and fasten duct sections together. Figure 1 shows the inner duct fitting complete with rubber seal. This seal provides the air seal for the completed fitting and is shaped to allow the inner and outer fittings to slide together, and then to lock the fittings in place. The illustration in Figure 2 shows the approximate cross section of the rubber seal that shows how the seal has a lip that is angled backwards. This angled lip allows the joint to be pushed together by folding flat but then its long axis makes it stiff in the pulling apart direction. This study was undertaken to assist PEG in some of the design aspects of this system and to test the performance of the PEGIT system. This study was carried out in three phases. The initial phase evaluated the performance of a preliminary seal design for the PEGIT system. After the first phase, the seal was redesigned and this new seal was evaluated in the second phase of testing. The third phase performed more detailed testing of the second seal design to optimize the production tolerances of the sheet metal fittings. This report summarizes our findings from the first two phases and provides details about the third phase of testing.

  6. Design definition study of a lift/cruise fan technology V/STOL airplane: Summary

    Science.gov (United States)

    Zabinsky, J. M.; Higgins, H. C.

    1975-01-01

    A two-engine three-fan V/STOL airplane was designed to fulfill naval operational requirements. A multimission airplane was developed from study of specific point designs. Based on the multimission concept, airplanes were designed to demonstrate and develop the technology and operational procedures for this class of aircraft. Use of interconnected variable pitch fans led to a good balance between high thrust with responsive control and efficient thrust at cruise speeds. The airplanes and their characteristics are presented.

  7. Progress on Variable Cycle Engines

    Science.gov (United States)

    Westmoreland, J. S.; Howlett, R. A.; Lohmann, R. P.

    1979-01-01

    Progress in the development and future requirements of the Variable Stream Control Engine (VSCE) are presented. The two most critical components of this advanced system for future supersonic transports, the high performance duct burner for thrust augmentation, and the low jet coannular nozzle were studied. Nozzle model tests substantiated the jet noise benefit associated with the unique velocity profile possible with a coannular nozzle system on a VSCE. Additional nozzle model performance tests have established high thrust efficiency levels only at takeoff and supersonic cruise for this nozzle system. An experimental program involving both isolated component and complete engine tests has been conducted for the high performance, low emissions duct burner with good results and large scale testing of these two components is being conducted using a F100 engine as the testbed for simulating the VSCE. Future work includes application of computer programs for supersonic flow fields to coannular nozzle geometries, further experimental testing with the duct burner segment rig, and the use of the Variable Cycle Engine (VCE) Testbed Program for evaluating the VSCE duct burner and coannular nozzle technologies.

  8. Follow-On Studies for Design Definition of a Lift/Cruise Fan Technology V/STOL Airplane, Volume 1

    Science.gov (United States)

    1977-01-01

    A three engine, three fan V/STOL airplane was designed for use as a Research Technology Airplane in proof-of-concept of a candidate configuration for use as a Navy multimission airplane. Use of mechanically interconnected variable pitch fans is made to accommodate power transfer for flight control in hover and to provide flight capability in the event of a single engine failure. The airplane is a modification of a T-39A transport. Design definition is provided for high risk propulsion components and a development test program is defined.

  9. Active Vibration Reduction of Titanium Alloy Fan Blades (FAN1) Using Piezoelectric Materials

    Science.gov (United States)

    Choi, Benjamin; Kauffman, Jeffrey; Duffy, Kirsten; Provenza, Andrew; Morrison, Carlos

    2010-01-01

    The NASA Glenn Research Center is developing smart adaptive structures to improve fan blade damping at resonances using piezoelectric (PE) transducers. In this paper, a digital resonant control technique emulating passive shunt circuits is used to demonstrate vibration reduction of FAN1 Ti real fan blade at the several target modes. Single-mode control and multi-mode control using one piezoelectric material are demonstrated. Also a conceptual study of how to implement this digital control system into the rotating fan blade is discussed.

  10. Online Fan Practices and CALL

    Science.gov (United States)

    Sauro, Shannon

    2017-01-01

    This article provides a narrative overview of research on online fan practices for language and literacy learning, use, and identity work. I begin with an introduction to online fan communities and common fan practices found in these online affinity spaces, the best known of which is fan fiction, fictional writing that reinterprets and remixes the…

  11. 75 FR 43878 - Airworthiness Directives; DASSAULT AVIATION Model Falcon 10 Airplanes; Model FAN JET FALCON, FAN...

    Science.gov (United States)

    2010-07-27

    ... Model Falcon 10 Airplanes; Model FAN JET FALCON, FAN JET FALCON SERIES C, D, E, F, and G Airplanes.... Since that NPRM was issued, we have determined that Model FAN JET FALCON SERIES C, D, E, F, and G..., Model FAN JET FALCON, FAN JET FALCON SERIES C, D, E, F, and G airplanes, and Model MYSTERE-FALCON 20-C5...

  12. Multimodal method for scattering of sound at a sudden area expansion in a duct with subsonic flow

    NARCIS (Netherlands)

    Kooijman, G.; Testud, P.; Aurégan, Y.; Hirschberg, A.

    2008-01-01

    The scattering of sound at a sudden area expansion in a duct with subsonic mean flow has been modelled with a multimodal method. Technological applications are for instance internal combustion engine exhaust silencers and silencers in industrial duct systems. Both two-dimensional (2D) rectangular

  13. Transcystic duct treatment of common bile duct stones

    International Nuclear Information System (INIS)

    Amberg, J.R.; Chun, G.

    1981-01-01

    Successful removal of 2 retained common bile duct stones following cholecystostomy is described. With the use of the steerable catheter and the wire basket, one stone was crushed and the second was extracted in retrograde fashion through the cystic duct and gallbladder. (orig.)

  14. Embedded Acoustic Sensor Array for Engine Fan Noise Source Diagnostic Test: Feasibility of Noise Telemetry via Wireless Smart Sensors

    Science.gov (United States)

    Zaman, Afroz; Bauch, Matthew; Raible, Daniel

    2011-01-01

    Aircraft engines have evolved into a highly complex system to meet ever-increasing demands. The evolution of engine technologies has primarily been driven by fuel efficiency, reliability, as well as engine noise concerns. One of the sources of engine noise is pressure fluctuations that are induced on the stator vanes. These local pressure fluctuations, once produced, propagate and coalesce with the pressure waves originating elsewhere on the stator to form a spinning pressure pattern. Depending on the duct geometry, air flow, and frequency of fluctuations, these spinning pressure patterns are self-sustaining and result in noise which eventually radiate to the far-field from engine. To investigate the nature of vane pressure fluctuations and the resulting engine noise, unsteady pressure signatures from an array of embedded acoustic sensors are recorded as a part of vane noise source diagnostics. Output time signatures from these sensors are routed to a control and data processing station adding complexity to the system and cable loss to the measured signal. "Smart" wireless sensors have data processing capability at the sensor locations which further increases the potential of wireless sensors. Smart sensors can process measured data locally and transmit only the important information through wireless communication. The aim of this wireless noise telemetry task was to demonstrate a single acoustic sensor wireless link for unsteady pressure measurement, and thus, establish the feasibility of distributed smart sensors scheme for aircraft engine vane surface unsteady pressure data transmission and characterization.

  15. Impact of cyclostationarity on fan broadband noise prediction

    Science.gov (United States)

    Wohlbrandt, A.; Kissner, C.; Guérin, S.

    2018-04-01

    One of the dominant noise sources of modern Ultra High Bypass Ratio (UHBR) engines is the interaction of the rotor wakes with the leading edges of the stator vanes in the fan stage. While the tonal components of this noise generation mechanism are fairly well understood by now, the broadband components are not. This calls to further the understanding of the broadband noise generation in the fan stage. This article introduces a new extension to the Random Particle Mesh (RPM) method, which accommodates in-depth studies of the impact of cyclostationary wake characteristics on the broadband noise in the fan stage. The RPM method is used to synthesize a turbulence field in the stator domain using a URANS simulation characterized by time-periodic turbulence and mean flow. The rotor-stator interaction noise is predicted by a two-dimensional CAA computation of the stator cascade. The impact of cyclostationarity is decomposed into various effects, which are separately investigated. This leads to the finding that the periodic turbulent kinetic energy (TKE) and periodic flow have only a negligible effect on the radiated sound power. The impact of the periodic integral length scale (TLS) is, however, substantial. The limits of a stationary representation of the TLS are demonstrated making this new extension to the RPM method indispensable when background and wake TKE are of comparable level. Good agreement of the predictions with measurements obtained from the 2015 AIAA Fan Broadband Noise Prediction Workshop are also shown.

  16. Experimental impact testing and analysis of composite fan cases

    Science.gov (United States)

    Vander Klok, Andrew Joe

    For aircraft engine certification, one of the requirements is to demonstrate the ability of the engine to withstand a fan blade-out (FBO) event. A FBO event may be caused by fatigue failure of the fan blade itself or by impact damage of foreign objects such as bird strike. An un-contained blade can damage flight critical engine components or even the fuselage. The design of a containment structure is related to numerous parameters such as the blade tip speed; blade material, size and shape; hub/tip diameter; fan case material, configuration, rigidity, etc. To investigate all parameters by spin experiments with a full size rotor assembly can be prohibitively expensive. Gas gun experiments can generate useful data for the design of engine containment cases at much lower costs. To replicate the damage modes similar to that on a fan case in FBO testing, the gas gun experiment has to be carefully designed. To investigate the experimental procedure and data acquisition techniques for FBO test, a low cost, small spin rig was first constructed. FBO tests were carried out with the small rig. The observed blade-to-fan case interactions were similar to those reported using larger spin rigs. The small rig has the potential in a variety of applications from investigating FBO events, verifying concept designs of rotors, to developing spin testing techniques. This rig was used in the developments of the notched blade releasing mechanism, a wire trigger method for synchronized data acquisition, high speed video imaging and etc. A relationship between the notch depth and the release speed was developed and verified. Next, an original custom designed spin testing facility was constructed. Driven by a 40HP, 40,000rpm air turbine, the spin rig is housed in a vacuum chamber of phi72inx40in (1829mmx1016mm). The heavily armored chamber is furnished with 9 viewports. This facility enables unprecedented investigations of FBO events. In parallel, a 15.4ft (4.7m) long phi4.1inch (105mm

  17. Rare bile duct anomaly: B3 duct draining to gallbladder

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2016-01-01

    Full Text Available A 10-year-old girl presented with recurrent right upper abdominal pain and dyspepsia. Magnetic resonance cholangiopancreatography revealed a dilated common channel of intrahepatic bile duct of segment 3 (B3 and segment 4 (B4 drained into the gallbladder directly. The patient underwent laparoscopic cholecystectomy and Roux-en Y hepaticojejunostomy (B3-jejunostomy. Among the anatomical variability of the biliary system, the cholecystohepatic ducts are controversial in existence and incidence. We report a very rare variant of a cholecystohepatic duct in which the B3 duct drained into gallbladder directly and to the best of our knowledge this is the first report.

  18. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark Raymond [Univ. of California, Berkeley, CA (United States)

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 μm were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the

  19. Curved-Duct

    Directory of Open Access Journals (Sweden)

    Je Hyun Baekt

    2000-01-01

    Full Text Available A numerical study is conducted on the fully-developed laminar flow of an incompressible viscous fluid in a square duct rotating about a perpendicular axis to the axial direction of the duct. At the straight duct, the rotation produces vortices due to the Coriolis force. Generally two vortex cells are formed and the axial velocity distribution is distorted by the effect of this Coriolis force. When a convective force is weak, two counter-rotating vortices are shown with a quasi-parabolic axial velocity profile for weak rotation rates. As the rotation rate increases, the axial velocity on the vertical centreline of the duct begins to flatten and the location of vorticity center is moved near to wall by the effect of the Coriolis force. When the convective inertia force is strong, a double-vortex secondary flow appears in the transverse planes of the duct for weak rotation rates but as the speed of rotation increases the secondary flow is shown to split into an asymmetric configuration of four counter-rotating vortices. If the rotation rates are increased further, the secondary flow restabilizes to a slightly asymmetric double-vortex configuration. Also, a numerical study is conducted on the laminar flow of an incompressible viscous fluid in a 90°-bend square duct that rotates about axis parallel to the axial direction of the inlet. At a 90°-bend square duct, the feature of flow by the effect of a Coriolis force and a centrifugal force, namely a secondary flow by the centrifugal force in the curved region and the Coriolis force in the downstream region, is shown since the centrifugal force in curved region and the Coriolis force in downstream region are dominant respectively.

  20. Comparison of BacT/Alert FAN and FAN Plus Bottles with Conventional Medium for Culturing Cerebrospinal Fluid.

    Science.gov (United States)

    Yoo, In Young; Chun, Sejong; Song, Dong Joon; Huh, Hee Jae; Lee, Nam Yong

    2016-11-01

    We compared the BacT/Alert system FAN and FAN Plus media to conventional media for culturing cerebrospinal fluid (CSF) with 2,545 samples. FAN/FAN Plus bottles showed better performance for isolating microorganisms in CSF than conventional media (positive rate, 7.2% [182/2,545] versus 3.1% [80/2,545]). The incremental recovery rate of Cryptococcus neoformans from FAN Plus bottles was higher than that from FAN bottles. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  1. Bile Duct Cancer (Cholangiocarcinoma)

    Science.gov (United States)

    ... Home > Types of Cancer > Bile Duct Cancer (Cholangiocarcinoma) Bile Duct Cancer (Cholangiocarcinoma) This is Cancer.Net’s Guide to Bile Duct Cancer (Cholangiocarcinoma). Use the menu below to ...

  2. Industrial fans used in nuclear facilities

    International Nuclear Information System (INIS)

    Carlson, J.A.

    1987-01-01

    Industrial fans are widely used in nuclear facilities, and their most common use is in building ventilation. To control the spread of contamination, airflows are maintained at high levels. Therefore, the selection of the fan and fan control are important to the safety of people, equipment and the environment. As a result, 80% of all energy used in nuclear facilities is fan energy. Safety evolves from the durability, control and redundancy in the system. In new or retrofit installations, testing and qualification of fans and systems are completed prior to start-up. Less important but necessary is the energy conservation aspect of fan selection and installations. Fan efficiency, type of control and system installation are evaluated for energy use

  3. Forced Response Analysis of a Fan with Boundary Layer Inlet Distortion

    Science.gov (United States)

    Bakhle, Milind A.; Reddy, T. S. R.; Coroneos, Rula M.

    2014-01-01

    Boundary layer ingesting propulsion systems have the potential to significantly reduce fuel burn for future generations of commercial aircraft, but these systems must be designed to overcome the challenge of high dynamic stresses in fan blades due to forced response. High dynamic stresses can lead to high cycle fatigue failures. High-fidelity computational analysis of the fan aeromechanics is integral to an ongoing effort to design a boundary layer ingesting inlet and fan for a wind-tunnel test. An unsteady flow solution from a Reynoldsaveraged Navier Stokes analysis of a coupled inlet-fan system is used to calculate blade unsteady loading and assess forced response of the fan to distorted inflow. Conducted prior to the mechanical design of a fan, the initial forced response analyses performed in this study provide an early look at the levels of dynamic stresses that are likely to be encountered. For the boundary layer ingesting inlet, the distortion contains strong engine order excitations that act simultaneously. The combined effect of these harmonics was considered in the calculation of the forced response stresses. Together, static and dynamic stresses can provide the information necessary to evaluate whether the blades are likely to fail due to high cycle fatigue. Based on the analyses done, the overspeed condition is likely to result in the smallest stress margin in terms of the mean and alternating stresses. Additional work is ongoing to expand the analyses to off-design conditions, on-resonance conditions, and to include more detailed modeling of the blade structure.

  4. Heat Flow Characteristics of a Newly-Designed Cooling System with Multi-Fans and Thermal Baffle in the Wheel Loader

    Directory of Open Access Journals (Sweden)

    Yidai Liao

    2017-03-01

    Full Text Available In the traditional cooling case, there is usually one fan in charge of heat transfer and airflow for all radiators. However, this seems to be inappropriate, or even insufficient, for modern construction machinery, as its overall heat flow density is increasing but thermal distribution is becoming uneven. In order to ensure that the machine works in a better condition, this paper employs a new cooling system with multiple fans and an independent cooling region. Based on the thermal flow and performance requirements, seven fans are divided into three groups. The independent cooling region is segregated from the engine region by a thermal baffle to avoid heat flowing into the engine region and inducing an overheat phenomenon. The experiment validates the efficiency of the new cooling system and accuracy of simulation. After validation, the simulation then analyzes heat transfer and flow characteristics of the cooling system, changing with different cross-sections in different axis directions, as well as different distances of the fan central axes. Finally, thermal baffles are set among the fan groups and provided a better cooling effect. The research realizes a multi-fan scheme with an independent cooling region in a wheel loader, which is a new, but high-efficiency, cooling system and will lead to a new change of various configurations and project designs in future construction machinery.

  5. Predicting the Inflow Distortion Tone Noise of the NASA Glenn Advanced Noise Control Fan with a Combined Quadrupole-Dipole Model

    Science.gov (United States)

    Koch, L. Danielle

    2012-01-01

    A combined quadrupole-dipole model of fan inflow distortion tone noise has been extended to calculate tone sound power levels generated by obstructions arranged in circumferentially asymmetric locations upstream of a rotor. Trends in calculated sound power level agreed well with measurements from tests conducted in 2007 in the NASA Glenn Advanced Noise Control Fan. Calculated values of sound power levels radiated upstream were demonstrated to be sensitive to the accuracy of the modeled wakes from the cylindrical rods that were placed upstream of the fan to distort the inflow. Results indicate a continued need to obtain accurate aerodynamic predictions and measurements at the fan inlet plane as engineers work towards developing fan inflow distortion tone noise prediction tools.

  6. Developing flow in S-shaped ducts. 2: Circular cross-section duct

    Science.gov (United States)

    Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.

    1984-01-01

    Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.

  7. Observational Analysis of Coronal Fans

    Science.gov (United States)

    Talpeanu, D.-C.; Rachmeler, L; Mierla, Marilena

    2017-01-01

    Coronal fans (see Figure 1) are bright observational structures that extend to large distances above the solar surface and can easily be seen in EUV (174 angstrom) above the limb. They have a very long lifetime and can live up to several Carrington rotations (CR), remaining relatively stationary for many months. Note that they are not off-limb manifestation of similarly-named active region fans. The solar conditions required to create coronal fans are not well understood. The goal of this research was to find as many associations as possible of coronal fans with other solar features and to gain a better understanding of these structures. Therefore, we analyzed many fans and created an overview of their properties. We present the results of this statistical analysis and also a case study on the longest living fan.

  8. Nondestructive Evaluation of the J-2X Direct Metal Laser Sintered Gas Generator Discharge Duct

    Science.gov (United States)

    Esther, Elizabeth A.; Beshears, Ronald D.; Lash, Rhonda K.

    2012-01-01

    The J-2X program at NASA's Marshall Space Flight Center (MSFC) procured a direct metal laser sintered (DMLS) gas generator discharge duct from Pratt & Whitney Rocketdyne and Morris Technologies for a test program that would evaluate the material properties and durability of the duct in an engine-like environment. DMLS technology was pursued as a manufacturing alternative to traditional techniques, which used off nominal practices to manufacture the gas generator duct's 180 degree turn geometry. MSFC's Nondestructive Evaluation (NDE) Team performed radiographic, ultrasonic, computed tomographic, and fluorescent penetrant examinations of the duct. Results from the NDE examinations reveal some shallow porosity but no major defects in the as-manufactured material. NDE examinations were also performed after hot-fire testing the gas generator duct and yielded similar results pre and post-test and showed no flaw growth or development.

  9. The Fan Effect Co-production, Communication & Dispute Between Digital Game Fans, Developers and Publishers

    OpenAIRE

    Jalamo, Tuomas

    2016-01-01

    This study analyses the relationship between video game fans, developers and publishers. The topic is approached via a case study that explores online fan reviews of the video game Mass Effect 3 at the Metacritic website. The game had a controversial ending, which was posthumously altered due to negative feedback from the fans. The study seeks to understand the ways in which the case study reflects the issues between the fans and the industry and how these themes are related to the wider disc...

  10. Aeromechanics Analysis of a Distortion-Tolerant Fan with Boundary Layer Ingestion

    Science.gov (United States)

    Bakhle, Milind A.; Reddy, T. S. R.; Coroneos, Rula M.; Min, James B.; Provenza, Andrew J.; Duffy, Kirsten P.; Stefko, George L.; Heinlein, Gregory S.

    2018-01-01

    A propulsion system with Boundary Layer Ingestion (BLI) has the potential to significantly reduce aircraft engine fuel burn. But a critical challenge is to design a fan that can operate continuously with a persistent BLI distortion without aeromechanical failure -- flutter or high cycle fatigue due to forced response. High-fidelity computational aeromechanics analysis can be very valuable to support the design of a fan that has satisfactory aeromechanic characteristics and good aerodynamic performance and operability. Detailed aeromechanics analyses together with careful monitoring of the test article is necessary to avoid unexpected problems or failures during testing. In the present work, an aeromechanics analysis based on a three-dimensional, time-accurate, Reynolds-averaged Navier-Stokes computational fluid dynamics code is used to study the performance and aeromechanical characteristics of the fan in both circumferentially-uniform and circumferentially-varying distorted flows. Pre-test aeromechanics analyses are used to prepare for the wind tunnel test and comparisons are made with measured blade vibration data after the test. The analysis shows that the fan has low levels of aerodynamic damping at various operating conditions examined. In the test, the fan remained free of flutter except at one near-stall operating condition. Analysis could not be performed at this low mass flow rate operating condition since it fell beyond the limit of numerical stability of the analysis code. The measured resonant forced response at a specific low-response crossing indicated that the analysis under-predicted this response and work is in progress to understand possible sources of differences and to analyze other larger resonant responses. Follow-on work is also planned with a coupled inlet-fan aeromechanics analysis that will more accurately represent the interactions between the fan and BLI distortion.

  11. 30 CFR 57.4504 - Fan installations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fan installations. 57.4504 Section 57.4504... Control Installation/construction/maintenance § 57.4504 Fan installations. (a) Fan houses, fan bulkheads... of combustible materials, except installed wiring, ground and track support, headframes, and direct...

  12. Shape memory alloy actuation for a variable area fan nozzle

    Science.gov (United States)

    Rey, Nancy; Tillman, Gregory; Miller, Robin M.; Wynosky, Thomas; Larkin, Michael J.; Flamm, Jeffrey D.; Bangert, Linda S.

    2001-06-01

    The ability to control fan nozzle exit area is an enabling technology for next generation high-bypass-ratio turbofan engines. Performance benefits for such designs are estimated at up to 9% in thrust specific fuel consumption (TSFC) relative to current fixed-geometry engines. Conventionally actuated variable area fan nozzle (VAN) concepts tend to be heavy and complicated, with significant aircraft integration, reliability and packaging issues. The goal of this effort was to eliminate these undesirable features and formulate a design that meets or exceeds leakage, durability, reliability, maintenance and manufacturing cost goals. A Shape Memory Alloy (SMA) bundled cable actuator acting to move an array of flaps around the fan nozzle annulus is a concept that meets these requirements. The SMA bundled cable actuator developed by the United Technologies Corporation (Patents Pending) provides significant work output (greater than 2200 in-lb per flap, through the range of motion) in a compact package and minimizes system complexity. Results of a detailed design study indicate substantial engine performance, weight, and range benefits. The SMA- based actuation system is roughly two times lighter than a conventional mechanical system, with significant aircraft direct operating cost savings (2-3%) and range improvements (5-6%) relative to a fixed-geometry nozzle geared turbofan. A full-scale sector model of this VAN system was built and then tested at the Jet Exit Test Facility at NASA Langley to demonstrate the system's ability to achieve 20% area variation of the nozzle under full scale aerodynamic loads. The actuator exceeded requirements, achieving repeated actuation against full-scale loads representative of typical cruise as well as greater than worst-case (ultimate) aerodynamic conditions. Based on these encouraging results, work is continuing with the goal of a flight test on a C-17 transport aircraft.

  13. RUO-FAN QIU

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics. RUO-FAN QIU. Articles written in Pramana – Journal of Physics. Volume 89 Issue 6 December 2017 pp 81 Research Article. Three-dimensional coupled double-distribution-function lattice Boltzmann models for compressible Navier–Stokes equations · RUO-FAN QIU ...

  14. Structural dynamics of shroudless, hollow fan blades with composite in-lays

    Science.gov (United States)

    Aiello, R. A.; Hirschbein, M. S.; Chamis, C. C.

    1982-01-01

    Structural and dynamic analyses are presented for a shroudless, hollow titanium fan blade proposed for future use in aircraft turbine engines. The blade was modeled and analyzed using the composite blade structural analysis computer program (COBSTRAN); an integrated program consisting of mesh generators, composite mechanics codes, NASTRAN, and pre- and post-processors. Vibration and impact analyses are presented. The vibration analysis was conducted with COBSTRAN. Results show the effect of the centrifugal force field on frequencies, twist, and blade camber. Bird impact analysis was performed with the multi-mode blade impact computer program. This program uses the geometric model and modal analysis from the COBSTRAN vibration analysis to determine the gross impact response of the fan blades to bird strikes. The structural performance of this blade is also compared to a blade of similar design but with composite in-lays on the outer surface. Results show that the composite in-lays can be selected (designed) to substantially modify the mechanical performance of the shroudless, hollow fan blade.

  15. A CFD Case Study of a Fan Stage with Split Flow Path Subject to Total Pressure Distortion Inflow

    Science.gov (United States)

    To, Wai-Ming

    2017-01-01

    This report is the documentation of the work performed under the Hypersonic Project of the NASA's Fundamental Aeronautics Program. It was funded through Task Number NNC10E444T under GESS-2 Contract NNC06BA07B. The objective of the task is to develop advanced computational tools for the simulation of multi-stage turbomachinery in support of aeropropulsion. This includes work elements in extending the TURBO code and validating the multi-stage URANS (Unsteady Reynolds Averaged Navier Stokes) simulation results with the experimental data. The unsteady CFD (Computation Fluid Dynamics) calculations were performed in full wheel mode with and without screen generated total pressure distortion at the computational inflow boundary, as well as in single passage phase lag mode for uniform inflow. The experimental data were provided by NASA from the single stage RTA (Revolutionary Turbine Accelerator) fan test program.Significant non-uniform flow condition at the fan-face of the aeropropulsion system is frequentlyencountered in many of the advanced aerospace vehicles. These propulsion systems can be eithera podded or an embedded design employed in HWB (Hybrid Wing Body) airframe concept. It isalso a topic of interest in military applications, in which advanced air vehicles have already deployedsome form of embedded propulsion systems in their design because of the requirementsof compact and low observable inlets. Even in the conventional airframe/engine design, the fancould operate under such condition when the air vehicle is undergoing rapid maneuvering action.It is believed that a better understanding of the fan’s aerodynamic and aeromechanical responseto this type of operating condition or off design operation would be beneficial to designing distortiontolerant blades for improved engine operability.The objective for this research is to assess the capability of turbomachinery code as an analysistool in understanding the effects and evaluating the impact of flow distortion

  16. 14 CFR 29.908 - Cooling fans.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling fans. 29.908 Section 29.908... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant General § 29.908 Cooling fans. For cooling fans that are a part of a powerplant installation the following apply: (a) Category A. For cooling fans installed...

  17. Stranger than fiction: Fan identity in cosplay

    Directory of Open Access Journals (Sweden)

    Nicolle Lamerichs

    2011-09-01

    Full Text Available Academic accounts of fan cultures usually focus on creative practices such as fan fiction, fan videos, and fan art. Through these practices, fans, as an active audience, closely interpret existing texts and rework them with texts of their own. A practice scarcely examined is cosplay ("costume play", in which fans produce their own costumes inspired by fictional characters. Cosplay is a form of appropriation that transforms and actualizes an existing story in close connection to the fan community and the fan's own identity. I provide analytical insights into this fan practice, focusing on how it influences the subject. Cosplay is understood as a performative activity and analyzed through Judith Butler's concept of performativity. I specifically focus on boundaries between the body and dress, and on those between reality and fiction. I aim to show that cosplay emphasizes the personal enactment of a narrative, thereby offering new perspectives on fan identity.

  18. 40 CFR 86.1337-96 - Engine dynamometer test run.

    Science.gov (United States)

    2010-07-01

    .... Plug the canister port that is normally connected to the fuel tank. (ii) Prepare the engine... test should be performed. (2) Connect evacuated sample collection bags to the dilute exhaust and... turned off, turn off the engine cooling fan(s) if used, and the CVS blower (or disconnect the exhaust...

  19. Studi Eksperimen Aliran Melalui Square Duct dan Square Elbow 90º dengan Double Guide Vane pada Variasi Sudut Bukaan Damper

    Directory of Open Access Journals (Sweden)

    Andrew Jaya Nazar

    2017-01-01

    Full Text Available Instalasi saluran udara tidak hanya berupa pipa lurus, tetapi juga terdapat fitting/aksesoris perpipaan misalnya elbow 90o dan damper. Aksesoris perpipaan ini berfungsi agar saluran udara dapat terpasang sesuai dengan kebutuhan. Namun, penggunaan aksesoris perpipaan ini menyebabkan bertambahnya pressure drop akibat adanya friction loss dan separation loss. Pemasangan guide vane pada elbow 90o diharapkan dapat mengurangi pressure drop karena dapat mengurangi terjadinya secondary flow, namun hal ini dapat menambah kerugian akibat gaya gesek. Saat ini penghematan energi menjadi sorotan terutama dalam dunia industri. Penurunan pressure drop pada belokan perpipaan sangat diharapkan, agar dapat menghemat energi lebih. Untuk itu perlu dilakukan usaha agar dapat menurunkan pressure drop yang terjadi. Penelitian ini dilakukan secara eksperimen dengan benda uji saluran udara yang terdiri dari: upstream duct (straight duct, square elbow 90o dengan r/Dh=1,5 dan dilengkapi double guide vane, damper, downstream duct (straight duct, dan induced fan. Pengukuran parameter yang dibutuhkan dilakukan dengan menggunakan: pitot tube, inclined manometer, pressure tranducer. Dari eksperimen ini diperoleh bahwa profil kecepatan pada masing-masing variasi sudut bukaan damper sudah mendekati keadaan recovery aliran pada akhir section baik dari bidang vertikal maupun horizontal. Pressure drop yang terjadi semakin naik seiring dengan bertambahnya nilai bilangan Reynolds dan sudut bukaan damper. Nilai konstanta damper semakin naik dari bukaan sudut 0o hingga 30o.

  20. Composite Axial Flow Propulsor for Small Aircraft

    Directory of Open Access Journals (Sweden)

    R. Poul

    2005-01-01

    Full Text Available This work focuses on the design of an axial flow ducted fan driven by a reciprocating engine. The solution minimizes the turbulization of the flow around the aircraft. The fan has a rotor - stator configuration. Due to the need for low weight of the fan, a carbon/epoxy composite material was chosen for the blades and the driving shaft.The fan is designed for optimal isentropic efficiency and free vortex flow. A stress analysis of the rotor blade was performed using the Finite Element  Method. The skin of the blade is calculated as a laminate and the foam core as a solid. A static and dynamic analysis were made. The RTM technology is compared with other technologies and is described in detail. 

  1. yi fan zheng

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. YI FAN ZHENG. Articles written in Bulletin of Materials Science. Volume 40 Issue 7 December 2017 pp 1329-1333. Synthesis and enhanced photocatalytic activity of g-C 3 N 4 hybridized CdS nanoparticles · QING YING LIU YI LING QI YI FAN ZHENG XU CHUN SONG.

  2. Autogenic dynamics of debris-flow fans

    Science.gov (United States)

    van den Berg, Wilco; de Haas, Tjalling; Braat, Lisanne; Kleinhans, Maarten

    2015-04-01

    Alluvial fans develop their semi-conical shape by cyclic avulsion of their geomorphologically active sector from a fixed fan apex. These cyclic avulsions have been attributed to both allogenic and autogenic forcings and processes. Autogenic dynamics have been extensively studied on fluvial fans through physical scale experiments, and are governed by cyclic alternations of aggradation by unconfined sheet flow, fanhead incision leading to channelized flow, channel backfilling and avulsion. On debris-flow fans, however, autogenic dynamics have not yet been directly observed. We experimentally created debris-flow fans under constant extrinsic forcings, and show that autogenic dynamics are a fundamental intrinsic process on debris-flow fans. We found that autogenic cycles on debris-flow fans are driven by sequences of backfilling, avulsion and channelization, similar to the cycles on fluvial fans. However, the processes that govern these sequences are unique for debris-flow fans, and differ fundamentally from the processes that govern autogenic dynamics on fluvial fans. We experimentally observed that backfilling commenced after the debris flows reached their maximum possible extent. The next debris flows then progressively became shorter, driven by feedbacks on fan morphology and flow-dynamics. The progressively decreasing debris-flow length caused in-channel sedimentation, which led to increasing channel overflow and wider debris flows. This reduced the impulse of the liquefied flow body to the flow front, which then further reduced flow velocity and runout length, and induced further in-channel sedimentation. This commenced a positive feedback wherein debris flows became increasingly short and wide, until the channel was completely filled and the apex cross-profile was plano-convex. At this point, there was no preferential transport direction by channelization, and the debris flows progressively avulsed towards the steepest, preferential, flow path. Simultaneously

  3. ENERGY STAR Certified Ceiling Fans

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Ceiling Fans that are effective as of April 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=ceiling_fans.pr_crit_ceiling_fans

  4. ENERGY STAR Certified Ventilating Fans

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Ventilating Fans that are effective as of October 1, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=vent_fans.pr_crit_vent_fans

  5. Propagation of sound waves in ducts

    DEFF Research Database (Denmark)

    Jacobsen, Finn

    2000-01-01

    Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described.......Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described....

  6. Dynamic modeling and vibration characteristics analysis of the aero-engine dual-rotor system with Fan blade out

    Science.gov (United States)

    Yu, Pingchao; Zhang, Dayi; Ma, Yanhong; Hong, Jie

    2018-06-01

    Fan Blade Out (FBO) from a running rotor of the turbofan engine will not only introduce the sudden unbalance and inertia asymmetry into the rotor, but also apply large impact load and induce rotor-to-stator rubbing on the rotor, which makes the mass, gyroscopic and stiffness matrixes of the dynamic equation become time-varying and highly nonlinear, consequently leads to the system's complicated vibration. The dynamic analysis of the aero-engine rotor system is one essential requirement of the authorities and is vital to the aero-engine's safety. The paper aims at studying the dynamic responses of the complicated dual-rotor systems at instantaneous and windmilling statuses when FBO event occurs. The physical process and mechanical characteristics of the FBO event are described qualitatively, based on which the dynamic modeling for an aero-engine dual-rotor system is carried out considering several excitations caused by FBO. Meanwhile the transient response during the instantaneous status and steady-state response at the windmilling status are obtained. The results reveal that the sudden unbalance can induce impact load to the rotor, and lead to the sharp increase of the vibration amplitude and reaction force. The rub-impact will apply constraint effects on the rotor and restrict the transient vibration amplitude, while the inertia asymmetry has little influence on the transient response. When the rotor with huge unbalance operates at windmilling status, the rub-impact turns to be the main factor determining the rotor's dynamic behavior, and several potential motion states, such as instable dry whip, intermittent rubbing and synchronous full annular rubbing would happen on certain conditions.

  7. Duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma.

    Science.gov (United States)

    Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin

    2013-04-21

    At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.

  8. EFFECT OF CENTRAL FANS AND IN-DUCT FILTERS ON DEPOSITION RATES OF ULTRAFINE AND FINE PARTICLES IN AN OCCUPIED TOWNHOUSE

    Science.gov (United States)

    Airborne particles are implicated in morbidity and mortality of certain high-risk subpopulations. Exposure to particles occurs mostly indoors, where a main removal mechanism is deposition to surfaces. Deposition can be affected by the use of forced- air circulation through duct...

  9. Flow Through a Rectangular-to-Semiannular Diffusing Transition Duct

    Science.gov (United States)

    Foster, Jeff; Wendt, Bruce J.; Reichert, Bruce A.; Okiishi, Theodore H.

    1997-01-01

    Rectangular-to-semiannular diffusing transition ducts are critical inlet components on supersonic airplanes having bifucated engine inlets. This paper documents measured details of the flow through a rectangular-to-semiannular transition duct having an expansion area ratio of 1.53. Three-dimensional velocity vectors and total pressures at the exit plane of the diffuser are presented. Surface oil-flow visualization and surface static pressure data are shown. The tests were conducted with an inlet Mach number of 0.786 and a Reynolds number based on the inlet centerline velocity and exit diameter of 3.2 x 10(exp 6). The measured data are compared with previously published computational results. The ability of vortex generators to reduce circumferential total pressure distortion is demonstrated.

  10. Computing Gröbner fans

    DEFF Research Database (Denmark)

    Fukuda, K.; Jensen, Anders Nedergaard; Thomas, R.R.

    2005-01-01

    This paper presents algorithms for computing the Gröbner fan of an arbitrary polynomial ideal. The computation involves enumeration of all reduced Gröbner bases of the ideal. Our algorithms are based on a uniform definition of the Gröbner fan that applies to both homogeneous and non......-homogeneous ideals and a proof that this object is a polyhedral complex. We show that the cells of a Gröbner fan can easily be oriented acyclically and with a unique sink, allowing their enumeration by the memory-less reverse search procedure. The significance of this follows from the fact that Gröbner fans...... are not always normal fans of polyhedra in which case reverse search applies automatically. Computational results using our implementation of these algorithms in the software package Gfan are included....

  11. Two-Stage Centrifugal Fan

    Science.gov (United States)

    Converse, David

    2011-01-01

    Fan designs are often constrained by envelope, rotational speed, weight, and power. Aerodynamic performance and motor electrical performance are heavily influenced by rotational speed. The fan used in this work is at a practical limit for rotational speed due to motor performance characteristics, and there is no more space available in the packaging for a larger fan. The pressure rise requirements keep growing. The way to ordinarily accommodate a higher DP is to spin faster or grow the fan rotor diameter. The invention is to put two radially oriented stages on a single disk. Flow enters the first stage from the center; energy is imparted to the flow in the first stage blades, the flow is redirected some amount opposite to the direction of rotation in the fixed stators, and more energy is imparted to the flow in the second- stage blades. Without increasing either rotational speed or disk diameter, it is believed that as much as 50 percent more DP can be achieved with this design than with an ordinary, single-stage centrifugal design. This invention is useful primarily for fans having relatively low flow rates with relatively high pressure rise requirements.

  12. Physics basis and mechanical design of the actively cooled duct scraper protection for the JET neutral beam enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D.J. [UKAEA Fusion/Euratom Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)], E-mail: dwilson@jet.uk; Ciric, D.; Cox, S.J.; Jones, T.T.C.; Kovari, M. [UKAEA Fusion/Euratom Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Li Puma, A. [Association EURATOM-CEA, CEA-Cadarache, 13108 St. Paul-Lez-Durance (France); Martin, D.; Milnes, J.; Shannon, M.; Surrey, E. [UKAEA Fusion/Euratom Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2007-10-15

    The objectives of the JET neutral beam enhancement (NBE) include raising the delivered power from the present 25 MW to more than 34 MW and increasing the pulse length from 10 to 20 s. The additional power will be obtained partly by increasing the fractional energy components of the beam, resulting from acceleration of molecular ions, hence increasing the total particle flux. These changes place extreme demands on the design of the upgraded protection to the torus entry duct. The present inertial duct protection already reaches its thermomechanical limit in 10 s pulses, and active cooling of the upgraded duct protection is therefore essential. Extensive analysis of the pressure and temperature evolution in the present un-cooled duct established the relationship between gas re-emission and surface temperature for copper in this operating environment. This information was used in an integrated physics and engineering approach to the design of the actively cooled duct protection, taking into account the power loads from direct beam interception and re-ionisation. Surface temperature determines power density through the gas re-emission and consequential beam re-ionisation. These considerations define the normal operating point for the chosen enhanced hypervapotron element technology. This approach demonstrated that supplementary in situ duct cryopumping would not be needed, provided that the required heat-transfer performance could be met without any encroachment of the elements beyond the space envelope of the existing inertial duct protection plates. This requirement posed severe constraints on the mechanical design of the hypervapotron element array and its manifolding; the adopted engineering design solutions are presented.

  13. Reciprocity principle in duct acoustics

    Science.gov (United States)

    Cho, Y.-C.

    1979-01-01

    Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.

  14. PICNIC - FANS, ULTRAS AND HOOLIGANS - INTERNAL DIFFERENTIATE OF SUBCULTURE GROUP FOOTBALL FANS IN POLAND

    Directory of Open Access Journals (Sweden)

    Maciej Solinski

    2006-01-01

    Full Text Available This article is a main part of "Internal differentiate of subculture group of football fans in Poland" project. Author has tried to show how the subculture of football fans can be differentiate. Author ha presented three different subgroups of Polish fans. It is very important to divide this subculture, because each subgroup has different mentality and style. That is why I have paid the most attention on this element.

  15. Laboratory alluvial fans in one dimension.

    Science.gov (United States)

    Guerit, L; Métivier, F; Devauchelle, O; Lajeunesse, E; Barrier, L

    2014-08-01

    When they reach a flat plain, rivers often deposit their sediment load into a cone-shaped structure called alluvial fan. We present a simplified experimental setup that reproduces, in one dimension, basic features of alluvial fans. A mixture of water and glycerol transports and deposits glass beads between two transparent panels separated by a narrow gap. As the beads, which mimic natural sediments, get deposited in this gap, they form an almost one-dimensional fan. At a moderate sediment discharge, the fan grows quasistatically and maintains its slope just above the threshold for sediment transport. The water discharge determines this critical slope. At leading order, the sediment discharge only controls the velocity at which the fan grows. A more detailed analysis reveals a slight curvature of the fan profile, which relates directly to the rate at which sediments are transported.

  16. Manufacturing technology for advanced jet engines; Jisedai jetto engine no seizo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Hirakawa, H [Kawasaki Heavy Industries Ltd., Kobe (Japan)

    1997-04-05

    A part of the latest production technologies for aircraft jet engines is introduced. Outline of the turbofan engine, turbo-prop engine, and turbo-shaft engine are given. Every one of them employs a gas turbine engine comprising a compressor, combustor, and a turbine as the output generator. Increase in the turbine inlet temperature is effective for making the gas turbine engine more efficient. The development tread of heat resisting materials for realizing higher temperature is shown. The current status and future aspect of the manufacturing technology is discussed for each main component of the engine. Technological development for decreasing weight is important because the weight of the fan member increases when the fan diameter is increased to increase the bypass ratio. FRP is adopted for the blades and casing to decrease the weight of the compressor, and studies have been made on fiber reinforced materials to reduce the weight of the disks. The outlines of the latest manufacturing technologies for the combustor and turbine are introduced. 2 refs., 9 figs.

  17. Detailed Post-Soft Impact Progressive Damage Assessment for Hybrid Structure Jet Engines

    Science.gov (United States)

    Siddens, Aaron; Bayandor, Javid; Celestina, Mark L.

    2014-01-01

    Currently, certification of engine designs for resistance to bird strike is reliant on physical tests. Predictive modeling of engine structural damage has mostly been limited to evaluation of individual forward section components, such as fan blades within a fixed frame of reference, to direct impact with a bird. Such models must be extended to include interactions among engine components under operating conditions to evaluate the full extent of engine damage. This paper presents the results of a study aim to develop a methodology for evaluating bird strike damage in advanced propulsion systems incorporating hybrid composite/metal structures. The initial degradation and failure of individual fan blades struck by a bird were investigated. Subsequent damage to other fan blades and engine components due to resultant violent fan assembly vibrations and fragmentation was further evaluated. Various modeling parameters for the bird and engine components were investigated to determine guidelines for accurately capturing initial damage and progressive failure of engine components. Then, a novel hybrid structure modeling approach was investigated and incorporated into the crashworthiness methodology. Such a tool is invaluable to the process of design, development, and certification of future advanced propulsion systems.

  18. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    Energy Technology Data Exchange (ETDEWEB)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A. [University of Pennsylvania Perelman School of Medicine, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Rambhatla, Siri J. [Beth Israel Medical Center, Department of Pediatrics, Newark, NJ (United States); Sreedharan, Ram R. [University of Pennsylvania, Departments of Gastroenterology, Hepatology and Nutrition, The Children' s Hospital of Philadelphia, Perelman School of Medicine, Philadelphia, PA (United States)

    2015-08-15

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  19. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    International Nuclear Information System (INIS)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A.; Rambhatla, Siri J.; Sreedharan, Ram R.

    2015-01-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  20. Fans af Bruce

    DEFF Research Database (Denmark)

    Vaaben, Nana Katrine

    2007-01-01

    Analysen viser, hvordan det samme ritual under en koncert forener og opdeler de fans, der orienterer sig mod Bruce Springsteen. På den ene side forener ritualet hele publikum i en stor fælles "Intimitet for mange" og på den anden side splitter det dem, fordi det bliver tydeligt, hvem der er de...... rigtige fans, og hvem der tilhører "pøbelen"....

  1. 78 FR 21578 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-11

    ... Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... Company (GE) model GEnx-2B67 and GEnx-2B67B turbofan engines with booster anti-ice (BAI) air duct, part... GE model GEnx-2B67 and GEnx- 2B67B turbofan engines with BAI air duct, P/N 2469M32G01, and support...

  2. Bile duct stricture

    Science.gov (United States)

    ... duct, the tube that moves bile from the liver to the small intestine. Bile is a substance that helps with digestion. ... causes of this condition include: Cancer of the bile duct, liver or pancreas Damage and scarring due to a ...

  3. Blocked Tear Duct

    Science.gov (United States)

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  4. Fan Noise for a Concept Commercial Supersonic Transport

    Science.gov (United States)

    Stephens, David

    2017-01-01

    NASA is currently studying a commercial supersonic transport (CST) aircraft that could carry 35+ passengers at Mach 1.6+ with a 4000+nm range. The aircraft should also meet environmental goals for sonic boom, airport noise and emissions at cruise. With respect to airport noise, considerable effort has been put into predicting the noise due to the jet exhaust. This report describes an internal NASA effort to consider the contribution of fan noise to the overall engine noise of this class of aircraft.

  5. Advanced Trailing Edge Blowing Concepts for Fan Noise Control

    Directory of Open Access Journals (Sweden)

    Cezar RIZEA

    2012-03-01

    Full Text Available This study documents trailing edge blowing research performed to reduce rotor / stator interaction noise in turbofan engines. The existing technique of filling every velocity deficit requires a large amount of air and is therefore impractical. The purpose of this research is to investigate new blowing configurations in order to achieve noise reduction with lesser amounts of air. Using the new configurations air is not injected into every fan blade, but is instead varied circumferentially. For example, blowing air may be applied to alternating fan blades. This type of blowing configuration both reduces the amount of air used and changes the spectral shape of the tonal interaction noise. The original tones at the blade passing frequency and its harmonics are reduced and new tones are introduced between them. This change in the tonal spectral shape increases the performance of acoustic liners used in conjunction with trailing edge blowing.

  6. Analysis of Stainless Steel Sandwich Panels with a Metal Foam Care for Lightweight Fan Blade Design

    Science.gov (United States)

    Min, James B.; Ghosn, Louis J.; Lerch, Bradley A.; Raj, Sai V.; Holland, Frederic A., Jr.; Hebsur, Mohan G.

    2004-01-01

    The quest for cheap, low density and high performance materials in the design of aircraft and rotorcraft engine fan and propeller blades poses immense challenges to the materials and structural design engineers. Traditionally, these components have been fabricated using expensive materials such as light weight titanium alloys, polymeric composite materials and carbon-carbon composites. The present study investigates the use of P sandwich foam fan blade made up of solid face sheets and a metal foam core. The face sheets and the metal foam core material were an aerospace grade precipitation hardened 17-4 PH stainless steel with high strength and high toughness. The stiffness of the sandwich structure is increased by separating the two face sheets by a foam core. The resulting structure possesses a high stiffness while being lighter than a similar solid construction. Since the face sheets carry the applied bending loads, the sandwich architecture is a viable engineering concept. The material properties of 17-4 PH metal foam are reviewed briefly to describe the characteristics of the sandwich structure for a fan blade application. A vibration analysis for natural frequencies and P detailed stress analysis on the 17-4 PH sandwich foam blade design for different combinations of skin thickness and core volume %re presented with a comparison to a solid titanium blade.

  7. Comparison of the Standard of Air Leakage in Current Metal Duct Systems in the World

    Science.gov (United States)

    Di, Yuhui; Wang, Jiqian; Feng, Lu; Li, Xingwu; Hu, Chunlin; Shi, Junshe; Xu, Qingsong; Qiao, Leilei

    2018-01-01

    Based on the requirements of air leakage of metal ducts in Chinese design standards, technical measures and construction standards, this paper compares the development history, the classification of air pressure levels and the air tightness levels of air leakage standards of current Chinese and international metal ducts, sums up the differences, finds shortage by investigating the design and construction status and access to information, and makes recommendations, hoping to help the majority of engineering and technical personnel.

  8. Turboelectric Distributed Propulsion Engine Cycle Analysis for Hybrid-Wing-Body Aircraft

    Science.gov (United States)

    Felder, James L.; Kim, Hyun Dae; Brown, Gerald V.

    2009-01-01

    Meeting NASA's N+3 goals requires a fundamental shift in approach to aircraft and engine design. Material and design improvements allow higher pressure and higher temperature core engines which improve the thermal efficiency. Propulsive efficiency, the other half of the overall efficiency equation, however, is largely determined by the fan pressure ratio (FPR). Lower FPR increases propulsive efficiency, but also dramatically reduces fan shaft speed through the combination of larger diameter fans and reduced fan tip speed limits. The result is that below an FPR of 1.5 the maximum fan shaft speed makes direct drive turbines problematic. However, it is the low pressure ratio fans that allow the improvement in propulsive efficiency which, along with improvements in thermal efficiency in the core, contributes strongly to meeting the N+3 goals for fuel burn reduction. The lower fan exhaust velocities resulting from lower FPRs are also key to meeting the aircraft noise goals. Adding a gear box to the standard turbofan engine allows acceptable turbine speeds to be maintained. However, development of a 50,000+ hp gearbox required by fans in a large twin engine transport aircraft presents an extreme technical challenge, therefore another approach is needed. This paper presents a propulsion system which transmits power from the turbine to the fan electrically rather than mechanically. Recent and anticipated advances in high temperature superconducting generators, motors, and power lines offer the possibility that such devices can be used to transmit turbine power in aircraft without an excessive weight penalty. Moving to such a power transmission system does more than provide better matching between fan and turbine shaft speeds. The relative ease with which electrical power can be distributed throughout the aircraft opens up numerous other possibilities for new aircraft and propulsion configurations and modes of operation. This paper discusses a number of these new

  9. Experiencing fan activism: Understanding the power of fan activist organizations through members' narratives

    Directory of Open Access Journals (Sweden)

    Neta Kligler-Vilenchik

    2012-06-01

    Full Text Available Fan activism, forms of civic engagement and political participation growing out of experiences of fandom, is a powerful mode of mobilization, particularly for young people. Building on 40 interviews with members of two organizations representing different configurations of fan activism, this article discusses three emerging elements that are key to the experience of membership in such groups. We suggest that the strength of fan activist groups builds on successfully combining these elements: two that are common to fandom, shared media experiences and a sense of community, and one that is traditionally ascribed to volunteerism and activism, the wish to help.

  10. The creation of football slash fan fiction

    Directory of Open Access Journals (Sweden)

    Abby Waysdorf

    2015-06-01

    Full Text Available Although sports fandom and fan fiction are often thought of as different worlds, in the contemporary media environment, this is not the case. Sport is a popular source text for fan fiction, and high-level European football, one of the world's most watched sports, has long had an online fan fiction presence. In a study of the LiveJournal community Footballslash over the 2011–12 European football season, I investigate what makes football a suitable source text for fan fiction, especially slash fan fiction; what fan fiction authors are doing with football; and what this suggests about how football and fan fiction are used in the present day. I present a new understanding of football as a media text to be transformed as well as provide an in-depth look into how this type of real person slash is developed and thought of by its practitioners. In doing so, I show what happens when fandoms and fan practices converge in the 21st century.

  11. 30 CFR 75.302 - Main mine fans.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main mine fans. 75.302 Section 75.302 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.302 Main mine fans. Each coal mine shall be ventilated by one or more main mine fans. Booster fans shall not be installed underground to assist main mine...

  12. 30 CFR 57.8518 - Main and booster fans.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main and booster fans. 57.8518 Section 57.8518... and Underground § 57.8518 Main and booster fans. (a) All mine main and booster fans installed and used...-cycle shutdowns or planned or scheduled fan maintenance or fan adjustments where air quality is...

  13. Being of service: "X-Files" fans and social engagement

    Directory of Open Access Journals (Sweden)

    Bethan Jones

    2012-06-01

    Full Text Available I explore the ways in which celebrity charity and fan activism can lead to civic engagement and social change. Fan studies has moved away from the traditional view of fans as psychologically deficient and has begun to examine resistance within the cultural productions of fandom—fan fiction, for example, addressing gender imbalances in popular TV shows. However, scholarship on celebrity-focused fans still retains much of the stigmatizing language that mars early writing about fans. I examine the relationship between celebrity and fan; examine the role celebrity plays in framing fan charity; assess how fan investment affects celebrity charity work; and argue that fans are active participants in encouraging social awareness and charitable giving.

  14. Radon reduction using sub floor fans

    International Nuclear Information System (INIS)

    Harley, N.H.; Chittaporn, P.

    1996-01-01

    The basement and second floor 222 Rn concentrations in an energy efficient home were measured hourly for 6 y using continuous monitors of our design. The home had a subslab pipe network installed during construction, and for the past 2 y a 150 cfm fan was operative venting air via ductwork inside the chimney exiting on the roof. During this measurement interval, experiments were conducted with the fan in 3 modes: (1) with the subslab fan off, (2) in the conventional direction auctioning air from beneath the slab to outside, and (3) reversed, blowing outdoor air into the network under the slab. We have a large data base to show that the indoor 222 R n concentration varies inversely with the indoor/outdoor temperature difference. In order to compare the 3 fan modes directly, we selected 50 to 90 d periods when the outdoor temperature was essentially the same. For the 3 modes, the fan off, blowing upward, and blowing downward, the basement concentration averaged 80, 38, and 34 Bq m -3 , respectively. Radon peaks or surges occur over a period of about 1 d during falling barometric pressure. With the fan blowing downward, these 222 Rn peaks tend to be smaller but only marginally so. We conclude that in this home the reduction in 222 Rn with the fan and subslab pipe network operating was essentially the same regardless of the direction of flow from the fan

  15. Ducted fuel injection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Charles J.

    2018-03-06

    Various technologies presented herein relate to enhancing mixing inside a combustion chamber to form one or more locally premixed mixtures comprising fuel and charge-gas with low peak fuel to charge-gas ratios to enable minimal, or no, generation of soot and other undesired emissions during ignition and subsequent combustion of the locally premixed mixtures. To enable sufficient mixing of the fuel and charge-gas, a jet of fuel can be directed to pass through a bore of a duct causing charge-gas to be drawn into the bore creating turbulence to mix the fuel and the drawn charge-gas. The duct can be located proximate to an opening in a tip of a fuel injector. The duct can comprise of one or more holes along its length to enable charge-gas to be drawn into the bore, and further, the duct can cool the fuel and/or charge-gas prior to combustion.

  16. Novel Crosstalk Measurement Method for Multi-Core Fiber Fan-In/Fan-Out Devices

    DEFF Research Database (Denmark)

    Ye, Feihong; Ono, Hirotaka; Abe, Yoshiteru

    2016-01-01

    We propose a new crosstalk measurement method for multi-core fiber fan-in/fan-out devices utilizing the Fresnel reflection. Compared with the traditional method using core-to-core coupling between a multi-core fiber and a single-mode fiber, the proposed method has the advantages of high reliability...

  17. Dynamic response of Hovercraft lift fans

    Science.gov (United States)

    Moran, D. D.

    1981-08-01

    Hovercraft lift fans are subjected to varying back pressure due to wave action and craft motions when these vehicles are operating in a seaway. The oscillatory back pressure causes the fans to perform dynamically, exhibiting a hysteresis type of response and a corresponding degradation in mean performance. Since Hovercraft motions are influenced by variations in lift fan pressure and discharge, it is important to understand completely the nature of the dynamic performance of lift fans in order to completely solve the Hovercraft seakeeping problem. The present study was performed to determine and classify the instabilities encountered in a centrifugal fan operating against time-varying back pressure. A model-scale experiment was developed in which the fan discharge was directed into a flow-measuring device, terminating in a rotating valve which produced an oscillatory back pressure superimposed upon a mean aerodynamic resistance. Pressure and local velocity were measured as functions of time at several locations in the fan volute. The measurements permitted the identification of rotating (or propagating) stall in the impeller. One cell and two cell configurations were classified and the transient condition connecting these two configurations was observed. The mechanisms which lead to rotating stall in a centrifugal compressor are presented and discussed with specific reference to Hovercraft applications.

  18. Acceptance test report MICON software exhaust fan control

    International Nuclear Information System (INIS)

    Keck, R.D.

    1998-01-01

    This test procedure specifies instructions for acceptance testing of software for exhaust fan control under Project ESPT (Energy Savings Performance Contract). The software controls the operation of two emergency exhaust fans when there is a power failure. This report details the results of acceptance testing for the MICON software upgrades. One of the modifications is that only one of the emergency fans will operate at all times. If the operating fan shuts off or fails, the other fan will start and the operating fan will be stopped

  19. Thermal neutrons streaming in straight duct

    International Nuclear Information System (INIS)

    Jehouani, A.; Boulkheir, M.; Ichaoui, R.

    2000-01-01

    The neutron streaming in duct is due to two phenomena: a) direct propagation and b) reflection on duct wall. We have used the Monte Carlo method to evaluate the ratio of the reflected neutrons flux by the duct wall to the total flux at the exit of the duct for iron and aluminium. Ten neutrons energy groups are considered between 10 -5 eV and 10 eV. A Fortran program is developed to evaluate the neutron double differential albedo. It is shown that the two following approximations are largely justified: i) Three collisions in the duct wall are sufficient to attain the asymptotic limit of the multiscattered neutron double differential albedo ii) The points of entry and exit of the neutron in the duct wall may be considered the same for the multiscattered neutrons. For a punctual source at the mouth of the duct, we have determined the direct and the reflected part of the total thermal neutron flux at the exit of the duct for different lengths and different radius of the duct. For a punctual source, we have found that the major contribution to the total flux of neutrons at the exit is due to the neutron reflection by walls and the reflection contribution decreases when the neutron energy decreases. For a constant length of the duct, the reflected part decreases when the duct radius increases while for the disk shaped source we have found the opposite phenomena. The transmitted neutron flux distribution at the exit of the duct are determined for disk shaped source for different neutron energy and for different distance from the exit center. (author)

  20. An Integrated Numerical and Experimental Analysis for Enhancing the Performance of the Hidden Ceiling Fan

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2014-02-01

    Full Text Available Since the inlet and outlet of hidden ceiling fan are almost located at the same Plane; thus, an improper housing may cause inhale-return phenomenon which significantly affects its power consumption and performance. In this study, a comprehensive investigation by numerical and experimental techniques was used to predict and identify the flow pattern, airflow rate, efficiency, and noise for ceiling fans with different design parameters. The results showed that the unique inhale-return phenomenon happens for an inappropriate housing. Several key parameters, such as fan guard, housing ring, inlet-to-outlet area ratio, and blockage height, are evaluated for finding out the criterion to avoid the inhale-return flow. Consequently the study finds that fan guard changes the airflow to a wider distribution with a lower velocity. A minimum blockage distance and a maximum height of ring-plate are set at 80 mm and 30 mm, respectively. Also, it is suggested that the inlet area must be bigger than the outlet area. Moreover, all the parameters show the same trend under various rotational speeds. In conclusion, this systematic investigation not only provides the fan engineer's design ability to avoid the inhale-return phenomenon, but also the predicting capability on its aerodynamic and acoustic performances.

  1. Active Control of Low-Speed Fan Tonal Noise Using Actuators Mounted in Stator Vanes: Part III Results

    Science.gov (United States)

    Sutliff, Daniel L.; Remington, Paul J.; Walker, Bruce E.

    2003-01-01

    A test program to demonstrate simplification of Active Noise Control (ANC) systems relative to standard techniques was performed on the NASA Glenn Active Noise Control Fan from May through September 2001. The target mode was the m = 2 circumferential mode generated by the rotor-stator interaction at 2BPF. Seven radials (combined inlet and exhaust) were present at this condition. Several different error-sensing strategies were implemented. Integration of the error-sensors with passive treatment was investigated. These were: (i) an in-duct linear axial array, (ii) an induct steering array, (iii) a pylon-mounted array, and (iv) a near-field boom array. The effect of incorporating passive treatment was investigated as well as reducing the actuator count. These simplified systems were compared to a fully ANC specified system. Modal data acquired using the Rotating Rake are presented for a range of corrected fan rpm. Simplified control has been demonstrated to be possible but requires a well-known and dominant mode signature. The documented results here in are part III of a three-part series of reports with the same base title. Part I and II document the control system and error-sensing design and implementation.

  2. Vitellointestinal Duct Anomalies in Infancy

    OpenAIRE

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: paten...

  3. Turning Vanes in Exhaust Duct Flow: Study for Energy Efficiency, Optimization and Pressure Drop Mitigation

    Science.gov (United States)

    2014-09-01

    engine cycle. However, much is to be gained by researching and studying the effects of reducing backpressure on the engine by the exhaust gases. In many...in maintenance on the exhaust duct, and the effectiveness of WHR devices downstream of the 90o bend. To evaluate the problem of backpressure in...the front-end of the engine (air intake and the actual combustion cycle itself), the amount of resources for

  4. Introduction of a Cooling-Fan Efficiency Index

    DEFF Research Database (Denmark)

    Schiavon, S.; Melikov, Arsen Krikor

    2009-01-01

    In a warm environment, air movement with elevated velocity is a well-known cooling strategy. The local air movement is typically generated by cooling fans (e.g., ceiling fan, table fans, etc.). Appearance, power input, and price are the main parameters considered today when purchasing cooling fans...... in practice the recommended elevated velocities in warm environments presented in the present standards. The standards need to be revised....

  5. Investigating for failure of central ventilation fan blade

    International Nuclear Information System (INIS)

    Koo, Jae Raeyang; Ko Woo Sig; Kim, Yeon Hwan; Park, Kwang Ha

    2002-01-01

    During the operation, central ventilation fan stopped when switch 'on' condition. When central ventilation fan disassemble, ten blades of fan fractured. We have searched cause of failure. We had modeling one of the fan blades and analysis with computer programs. Thus we have find that fracture of central ventilation fan blades is alternative stress and vibration at hub. In this paper, we have described cause of failure

  6. PFP supply fan motor starters

    International Nuclear Information System (INIS)

    Keck, R.D.

    1995-01-01

    The Plutonium Finishing Plant (PFP) is currently stabilizing about 25 kg of Pu sludge; upon completion of this task, PFP will be maintained in a safe standby condition to await decision from the PFP NEPA review. It can take about 10 years to initiate and complete terminal cleanout after this; the facility will then be decommissioned and decontaminated. The 234-5Z ventilation system must continue to operate until terminal cleanout. Part of the ventilation system is the seismic fan shutdown system which shuts down the ventilation supply fans in case of strong earthquake. This document presents criteria for installing solid state, reduced voltage motor starters and isolation contactors for the 8 main ventilation supply fans. The isolation contactors will shutdown the supply fans in event of earthquake

  7. Patent arterial duct

    Directory of Open Access Journals (Sweden)

    Martin Robin P

    2009-07-01

    Full Text Available Abstract Patent arterial duct (PAD is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes. Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of

  8. Computer fan performance enhancement via acoustic perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Greenblatt, David, E-mail: davidg@technion.ac.il [Faculty of Mechanical Engineering, Technion - Israel Institute of Technology, Haifa (Israel); Avraham, Tzahi; Golan, Maayan [Faculty of Mechanical Engineering, Technion - Israel Institute of Technology, Haifa (Israel)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Computer fan effectiveness was increased by introducing acoustic perturbations. Black-Right-Pointing-Pointer Acoustic perturbations controlled blade boundary layer separation. Black-Right-Pointing-Pointer Optimum frequencies corresponded with airfoils studies. Black-Right-Pointing-Pointer Exploitation of flow instabilities was responsible for performance improvements. Black-Right-Pointing-Pointer Peak pressure and peak flowrate were increased by 40% and 15% respectively. - Abstract: A novel technique for increasing computer fan effectiveness, based on introducing acoustic perturbations onto the fan blades to control boundary layer separation, was assessed. Experiments were conducted in a specially designed facility that simultaneously allowed characterization of fan performance and introduction of the perturbations. A parametric study was conducted to determine the optimum control parameters, namely those that deliver the largest increase in fan pressure for a given flowrate. The optimum reduced frequencies corresponded with those identified on stationary airfoils and it was thus concluded that the exploitation of Kelvin-Helmholtz instabilities, commonly observed on airfoils, was responsible for the fan blade performance improvements. The optimum control inputs, such as acoustic frequency and sound pressure level, showed some variation with different fan flowrates. With the near-optimum control conditions identified, the full operational envelope of the fan, when subjected to acoustic perturbations, was assessed. The peak pressure and peak flowrate were increased by up to 40% and 15% respectively. The peak fan efficiency increased with acoustic perturbations but the overall system efficiency was reduced when the speaker input power was accounted for.

  9. Computer fan performance enhancement via acoustic perturbations

    International Nuclear Information System (INIS)

    Greenblatt, David; Avraham, Tzahi; Golan, Maayan

    2012-01-01

    Highlights: ► Computer fan effectiveness was increased by introducing acoustic perturbations. ► Acoustic perturbations controlled blade boundary layer separation. ► Optimum frequencies corresponded with airfoils studies. ► Exploitation of flow instabilities was responsible for performance improvements. ► Peak pressure and peak flowrate were increased by 40% and 15% respectively. - Abstract: A novel technique for increasing computer fan effectiveness, based on introducing acoustic perturbations onto the fan blades to control boundary layer separation, was assessed. Experiments were conducted in a specially designed facility that simultaneously allowed characterization of fan performance and introduction of the perturbations. A parametric study was conducted to determine the optimum control parameters, namely those that deliver the largest increase in fan pressure for a given flowrate. The optimum reduced frequencies corresponded with those identified on stationary airfoils and it was thus concluded that the exploitation of Kelvin–Helmholtz instabilities, commonly observed on airfoils, was responsible for the fan blade performance improvements. The optimum control inputs, such as acoustic frequency and sound pressure level, showed some variation with different fan flowrates. With the near-optimum control conditions identified, the full operational envelope of the fan, when subjected to acoustic perturbations, was assessed. The peak pressure and peak flowrate were increased by up to 40% and 15% respectively. The peak fan efficiency increased with acoustic perturbations but the overall system efficiency was reduced when the speaker input power was accounted for.

  10. Eversion Bile Duct Anastomosis: A Safe Alternative for Bile Duct Size Discrepancy in Deceased Donor Liver Transplantation.

    Science.gov (United States)

    Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw

    2018-04-10

    Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.

  11. Materials, Manufacturing, and Test Development of a Composite Fan Blade Leading Edge Subcomponent for Improved Impact Resistance

    Science.gov (United States)

    Miller, Sandi G.; Handschuh, Katherine; Sinnott, Matthew J.; Kohlman, Lee W.; Roberts, Gary D.; Martin, Richard E.; Ruggeri, Charles R.; Pereira, J. Michael

    2015-01-01

    Application of polymer matrix composite materials for jet engine fan blades is becoming attractive as an alternative to metallic blades; particularly for large engines where significant weight savings are recognized on moving to a composite structure. However, the weight benefit of the composite is offset by a reduction of aerodynamic efficiency resulting from a necessary increase in blade thickness; relative to the titanium blades. Blade dimensions are largely driven by resistance to damage on bird strike. Further development of the composite material is necessary to allow composite blade designs to approximate the dimensions of a metallic fan blade. The reduction in thickness over the state of the art composite blades is expected to translate into structural weight reduction, improved aerodynamic efficiency, and therefore reduced fuel consumption. This paper presents test article design, subcomponent blade leading edge fabrication, test method development, and initial results from ballistic impact of a gelatin projectile on the leading edge of composite fan blades. The simplified test article geometry was developed to realistically simulate a blade leading edge while decreasing fabrication complexity. Impact data is presented on baseline composite blades and toughened blades; where a considerable improvement to impact resistance was recorded.

  12. Study of blade aspect ratio on a compressor front stage aerodynamic and mechanical design report

    Science.gov (United States)

    Burger, G. D.; Lee, D.; Snow, D. W.

    1979-01-01

    A single stage compressor was designed with the intent of demonstrating that, for a tip speed and hub-tip ratio typical of an advanced core compressor front stage, the use of low aspect ratio can permit high levels of blade loading to be achieved at an acceptable level of efficiency. The design pressure ratio is 1.8 at an adiabatic efficiency of 88.5 percent. Both rotor and stator have multiple-circular-arc airfoil sections. Variable IGV and stator vanes permit low speed matching adjustments. The design incorporates an inlet duct representative of an engine transition duct between fan and high pressure compressor.

  13. Should you get your heating ducts cleaned?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Canada Mortgage and Housing Corporation conducted research into duct cleaning during which time several houses were tested for hot air furnace duct performance before and after cleaning. Duct cleaning is a major industry which claims that cleaning of ducts will provide you with better indoor air quality, reduce household molds and allergens, get rid of house dust, result in more airflow and better delivery of warm air and reduce energy costs. This report does not substantiate those claims. Researchers found little or no discernible differences in the concentrations of house airborne particles or in duct airflows due to duct cleaning. This is because ducts are metal passages that cannot create dust. Most household dusts come from outdoors that has been tracked in or blows through windows and other openings. While duct cleaning may be justifiable personally, it does not change the quality of the air you breathe, nor will it significantly affect airflow or heating costs. Some filters effectively clean the air in the ducts but they do not create a dust-free environment because of the above-mentioned dust sources. The only time that duct cleaning may make sense is if you have water in your ducts that can result in mold growth, if you are moving into a newly constructed house to remove drywall dust, if your are having trouble with furnace airflow, or if you see an accumulation of debris in the return air ducts. It was emphasized that broadcast spraying of biocides within the duct system should not be performed.

  14. 30 CFR 75.331 - Auxiliary fans and tubing.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Auxiliary fans and tubing. 75.331 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.331 Auxiliary fans and tubing. (a) When auxiliary fans and tubing are used for face ventilation, each auxiliary fan shall be— (1...

  15. 30 CFR 57.8519 - Underground main fan controls.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground main fan controls. 57.8519 Section... Ventilation Surface and Underground § 57.8519 Underground main fan controls. All underground main fans shall have controls placed at a suitable protected location remote from the fan and preferably on the surface...

  16. Evaluation of a high-temperature burner-duct-recuperator system

    Science.gov (United States)

    1990-07-01

    The U.S. Department of Energy's (DOE) Office of Industrial Technologies (OIT) sponsors research and development (R and D) to improve the energy efficiency of American industry and to provide for fuel flexibility. OIT has funded a multiyear R and D project by the Babcock and Wilcox Company (B and W) to design, fabricate, field test, and evaluate a high-temperature burner-duct-recuperator (HTBDR) system. This ceramic-based recuperator system recovers waste heat from the corrosive, high-temperature (2170 F) flue gas stream of a steel soaking pit to preheat combustion air to as high as 1700 F. The preheated air is supplied to a high-temperature burner. The B and W R and D program, which is now complete, involved several activities, including selecting and evaluating ceramic materials, designing the system, and developing and evaluating the prototype. In addition, a full-scale unit was tested at a B and W steel soaking pit. The full-scale system consisted of a modular single-stage ceramic recuperator, a conventional two-pass metallic recuperator, a high-temperature burner, fans, insulated ducting, and associated controls and instrumentation. The metallic recuperator preheated combustion air to about 750 F before it passed to the ceramic module. This technical case study describes the DOE/B and W recuperator project and highlights the field tests of the full-scale recuperator system. The document makes results of field tests and data analysis available to other researchers and private industry. It discusses project status, summarizes field tests, and reviews the potential effects the technology will have on energy use and system economics.

  17. Ferromanganese micronodules from Bengal Fan

    Digital Repository Service at National Institute of Oceanography (India)

    Chauhan, O.S.; Gujar, A.R.; Rao, Ch.M.

    The occurrence of ferromanganese micronodules, hitherto unreported from any fan-valley system of the world, has been recorded from over 0.22 million km sup(2) area located in the middle fan region of the Bay of Bengal. Their abundance is higher...

  18. Progress with variable cycle engines

    Science.gov (United States)

    Westmoreland, J. S.

    1980-01-01

    The evaluation of components of an advanced propulsion system for a future supersonic cruise vehicle is discussed. These components, a high performance duct burner for thrust augmentation and a low jet noise coannular exhaust nozzle, are part of the variable stream control engine. An experimental test program involving both isolated component and complete engine tests was conducted for the high performance, low emissions duct burner with excellent results. Nozzle model tests were completed which substantiate the inherent jet noise benefit associated with the unique velocity profile possible of a coannular exhaust nozzle system on a variable stream control engine. Additional nozzle model performance tests have established high thrust efficiency levels at takeoff and supersonic cruise for this nozzle system. Large scale testing of these two critical components is conducted using an F100 engine as the testbed for simulating the variable stream control engine.

  19. School spirits: alcohol and collegiate sports fans.

    Science.gov (United States)

    Nelson, Toben F; Wechsler, Henry

    2003-01-01

    While studies have addressed alcohol use and related problems among college athletes, little is known about the drinking patterns of non-athletes who are sports fans. This study examines the relationship between alcohol use and interest in collegiate sports on two levels. First, do sports fans in college binge drink more and exhibit more negative alcohol-related outcomes than other students? Second, do colleges with large numbers of sports fans have higher rates of heavy drinking and accompanying secondhand effects affecting other students? The study analyzed the responses of a nationally representative sample of students who completed questionnaires in the spring of 1999 regarding their extracurricular activities and substance use. The responses of 3445 student sports fans were compared to those of 8405 students who were not sports fans. More sports fans drank alcohol, engaged in binge drinking, had a heavy drinking style and reported alcohol-related problems than nonfans. The percentage of sports fans at a school was associated with binge drinking rates and the secondhand effects. The implications for those working with college athletics and for alcohol prevention personnel are discussed. Copyright 2002 Elsevier Science Ltd.

  20. Bydrage ta de kennis fan it libben, de persoan en it wurk fan Dr. Eeltsje Halbersma 1797-1858

    NARCIS (Netherlands)

    1946-01-01

    It doel fan dizze dissertaesje is yn 'e earste pleats nij materiael to bringen oer Dr. Eeltsje. De wichtichste boarnen foar syn libben en syn wurk binne syn brieven oan Ds, Joast. Oant nou ta wie fan dy brieven mar in lyts bytsje bikend wurden, Dêrneist binne fansels ek de brieven fan Ds. Joast en

  1. Bile Duct Adenoma with Oncocytic Features

    Directory of Open Access Journals (Sweden)

    E. J. Johannesen

    2014-01-01

    Full Text Available Bile duct adenomas are benign bile duct proliferations usually encountered as an incidental finding. Oncocytic bile duct neoplasms are rare and the majority are malignant. A 61-year-old male with a diagnosis of colorectal adenocarcinoma was undergoing surgery when a small white nodule was discovered on the surface of the right lobe of his liver. This lesion was composed of cytologically bland cells arranged in tightly packed glands. These cells were immunopositive for cytokeratin 7, negative for Hep Par 1, contained mucin, and had a Ki67 proliferation index of 8%. The morphology, immunophenotype, presence of mucin, and normal appearing bile ducts, as well as the increased Ki67 proliferation rate, were consistent with a bile duct adenoma with oxyphilic (oncocytic change. Oncocytic tumors in the liver are rare; the first described in 1992. Only two bile duct adenomas with oncocytic change have been reported and neither of them had reported mucin production or the presence of normal appearing bile ducts within the lesion.

  2. Nucleonic analysis of a preliminary design for the ETF neutral-beam-injector duct shielding

    International Nuclear Information System (INIS)

    Urban, W.T.; Seed, T.J.; Dudziak, D.J.

    1980-01-01

    A nucleonic analysis of the Engineering Test Facility Neutral-Beam-Injector duct shielding has been made using a hybrid Monte Carlo/discrete-ordinates method. This method used Monte Carlo to determine internal and external boundary surface sources for a subsequent discrete-ordinates calculation of the neutron and gamma-ray transport through the shield. The analysis also included determination of the energy and angular distribution of neutrons and gamma rays entering the duct from the torus plasma chamber. Confidence in the hybrid method and the results obtained were provided through a comparison with three-dimensional Monte Carlo results

  3. Correlations for heat transfer coefficient and friction factor for turbulent flow of air through square and hexagonal ducts with twisted tape insert

    Science.gov (United States)

    Yadav, Rupesh J.; Kore, Sandeep S.; Joshi, Prathamesh S.

    2018-05-01

    The experimental and numerical Nusselt number and friction factor investigation for turbulent flow through a non-circular duct with twisted-tape inserts have been presented. The non-circular ducts include square, hexagonal duct. The results of non-circular ducts are compared with circular duct. All the ducts have same equivalent diameter. The twist ratios used for the experiment are Y = 3.5, 4.5, 5.5 and 6.5. Experiments were carried out on square duct, hexagonal duct and circular duct. The Reynolds number lied between 10,000 and 1, 05,000. The present study is restricted to the flow of air at Pr = 0.7 only and within a narrow temperature range of 40 to 75 ΟC, within which the compressible nature of air can be neglected. The results reveal that, both Nusselt number and friction factor increases as the side of non-circular duct increases. Maximum Nusselt number and friction factor is obtained in case of circular duct with twisted tape. Further the correlations of Nu and f are given for different non circular duct with twisted tape insert for engineering applications for the turbulent regime. Since the thermal performance factor (η) is observed to be within the range of 0.8 to 1.13 for both circular and noncircular ducts, the overall benefit of using twisted tape in the flow field shall nevertheless be marginal.

  4. Truncated Groebner fans and lattice ideals

    OpenAIRE

    Lauritzen, Niels

    2005-01-01

    We outline a generalization of the Groebner fan of a homogeneous ideal with maximal cells parametrizing truncated Groebner bases. This "truncated" Groebner fan is usually much smaller than the full Groebner fan and offers the natural framework for conversion between truncated Groebner bases. The generic Groebner walk generalizes naturally to this setting by using the Buchberger algorithm with truncation on facets. We specialize to the setting of lattice ideals. Here facets along the generic w...

  5. Submarine fans: A critical retrospective (1950–2015

    Directory of Open Access Journals (Sweden)

    G. Shanmugam

    2016-04-01

    Full Text Available When we look back the contributions on submarine fans during the past 65 years (1950–2015, the empirical data on 21 modern submarine fans and 10 ancient deep-water systems, published by the results of the First COMFAN (Committee on FANs Meeting (Bouma et al., 1985a, have remained the single most significant compilation of data on submarine fans. The 1970s were the “heyday” of submarine fan models. In the 21st century, the general focus has shifted from submarine fans to submarine mass movements, internal waves and tides, and contourites. The purpose of this review is to illustrate the complexity of issues surrounding the origin and classification of submarine fans. The principal elements of submarine fans, composed of canyons, channels, and lobes, are discussed using nine modern case studies from the Mediterranean Sea, the Equatorial Atlantic, the Gulf of Mexico, the North Pacific, the NE Indian Ocean (Bay of Bengal, and the East Sea (Korea. The Annot Sandstone (Eocene–Oligocene, exposed at Peira-Cava area, SE France, which served as the type locality for the “Bouma Sequence”, was reexamined. The field details are documented in questioning the validity of the model, which was the basis for the turbidite-fan link. The 29 fan-related models that are of conceptual significance, developed during the period 1970–2015, are discussed using modern and ancient systems. They are: (1 the classic submarine fan model with attached lobes, (2 the detached-lobe model, (3 the channel-levee complex without lobes, (4 the delta-fed ramp model, (5 the gully-lobe model, (6 the suprafan lobe model, (7 the depositional lobe model, (8 the fan lobe model, (9 the ponded lobe model, (10 the nine models based on grain size and sediment source, (11 the four fan models based on tectonic settings, (12 the Jackfork debrite model, (13 the basin-floor fan model, (14 supercritical and subcritical fans, and (15 the three types of fan reservoirs. Each model is unique

  6. 30 CFR 57.8529 - Auxiliary fan systems

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Auxiliary fan systems 57.8529 Section 57.8529 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Underground Only § 57.8529 Auxiliary fan systems When auxiliary fan systems are used, such systems shall...

  7. 30 CFR 57.8525 - Main fan maintenance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main fan maintenance. 57.8525 Section 57.8525 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Underground Only § 57.8525 Main fan maintenance. Main fans shall be maintained according to either the...

  8. Vacuum exhaust duct used for thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo; Kondo, Mitsuaki; Honda, Tsutomu.

    1990-01-01

    The present invention concerns a vacuum exhaust duct used for a thermonuclear device. A cylindrical metal liners is lined with a gap to the inside of a vacuum exhaust duct main body. Bellows are connected to both ends of the metal liners and the end of the bellows is welded to the vacuum exhaust duct main body. Futher, a heater is mounted to the metal liner on the side of the vacuum exhaust duct main body, and the metal liner is heated by the heater to conduct baking for the vacuum exhaust duct main body. Accordingly, since there is no requirement for elevating the temperature of the vacuum exhaust duct upon conducting baking, the vacuum exhaust duct scarcely suffers substantial deformation due to heat expansion. Further, there is also no substantial deformation for the bellows disposed between the outer circumference of the vacuum vessel and a portion of a vacuum exhaust duct, so that the durability of the bellows is greatly improved. (I.S.)

  9. Online Fan Fiction and Critical Media Literacy

    Science.gov (United States)

    Black, Rebecca W.

    2010-01-01

    This article explores English-language-learning (ELL) youths' engagement with popular media through composing and publicly posting stories in an online fan fiction writing space. Fan fiction is a genre that lends itself to critical engagement with media texts as fans repurpose popular media to design their own narratives. Analyses describe how…

  10. Quadcopter thrust optimization with ducted-propeller

    Directory of Open Access Journals (Sweden)

    Kuantama Endrowednes

    2017-01-01

    Full Text Available In relation to quadcopter body frame model, propeller can be categorized into propeller with ducted and without ducted. This study present differences between those two using CFD (Computational Fluid Dynamics method. Both categories utilize two blade-propeller with diameter of 406 (mm. Propeller rotation generates acceleration per time unit on the volume of air. Based on the behavior of generated air velocity, ducted propeller can be modeled into three versions. The generated thrust and performance on each model were calculated to determine the best model. The use of ducted propeller increases the total weight of quadcopter and also total thrust. The influence of this modeling were analyzed in detail with variation of angular velocity propeller from 1000 (rpm to 9000 (rpm. Besides the distance between propeller tip and ducted barrier, the size of ducted is also an important part in thrust optimization and total weight minimization of quadcopter.

  11. Motivational variables that influence fan attendance in domestic ...

    African Journals Online (AJOL)

    A convenience sample of 180 fans was surveyed from a Gauteng based team. A factor analytical approach revealed seven dimensions of fan motivation, namely, ... marketing communication strategies in various aspects of fan attendance.

  12. Radiation resistant ducted superconductive coil

    International Nuclear Information System (INIS)

    Schleich, A.

    1976-01-01

    The radiation-resistant ducted superconductive coil consists of a helically wound electrical conductor constituted by an electrically conductive core of superconductive material provided with a longitudinally extending cooling duct. The core is covered with a layer of inorganic insulating material and the duct is covered by an electrically conductive metallic gas-tight sheath. The metallic sheaths on adjacent turns of the coil are secured together. 2 Claims, 4 Drawing Figures

  13. Fan Cart: The Next Generation

    Science.gov (United States)

    Lamore, Brian

    2016-01-01

    For years the fan cart has provided physics students with an excellent resource for exploring fundamental mechanics concepts such as acceleration, Newton's laws, impulse, momentum, work-energy, and energy conversions. "The Physics Teacher" has even seen some excellent do-it-yourself (DIY) fan carts and activities. If you are interested…

  14. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  15. The "flying" bile duct: avulsion of the common bile duct in a plane crash survivor.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Blunt trauma is an unusual cause of extrahepatic bile duct injury. This is a case of a 51-year-old gentleman who sustained a significant seatbelt injury in a plane crash. Laparotomy, performed due to persistent abdominal pain, revealed that the common bile duct (CBD) was completely avulsed from the duodenum. Following insertion of drains and transfer to a hepatobiliary centre, the devascularised CBD was excised and replaced with a roux-en-y hepaticojejunostomy. Necrotic tissue was debrided from the pancreatic head. A persistent bile leak developed from the sub-hepatic drain. Repeat laparotomy revealed a bile leak from small ducts on the liver surface. Ligation of the ducts and bioglue sealing of the area were successfully performed. Subsequent to this a pancreatic fistula developed from the main pancreatic duct, which has since resolved. This unusual case illustrates the need for prompt recognition and early repair to optimise outcomes in traumatic CBD injury.

  16. Burnout data for flow of boiling water in vertical round ducts, annuli and rod clusters

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Kurt M; Hernborg, Gunnar; Bode, Manfred; Eriksson, O

    1965-07-01

    The present report contains the tables of the burnout data obtained for flow in vertical channels at the Heat Engineering Laboratory of AB Atomenergi in Sweden. The data covers measurements in round ducts, annuli, 3-rod and 7-rod clusters.

  17. Burnout data for flow of boiling water in vertical round ducts, annuli and rod clusters

    International Nuclear Information System (INIS)

    Becker, Kurt M.; Hernborg, Gunnar; Bode, Manfred; Eriksson, O.

    1965-01-01

    The present report contains the tables of the burnout data obtained for flow in vertical channels at the Heat Engineering Laboratory of AB Atomenergi in Sweden. The data covers measurements in round ducts, annuli, 3-rod and 7-rod clusters

  18. Fan edits and the legacy of The Phantom Edit

    Directory of Open Access Journals (Sweden)

    Joshua Wille

    2014-09-01

    Full Text Available A fan edit can generally be defined as an alternative version of a film or television text created by a fan. It offers a different viewing experience, much as a song remix offers a different listening experience. The contemporary wave of fan edits has emerged during the remix zeitgeist of digital media and at a time when digital video editing technology has become more affordable and popular. The increasing number of alternative versions of films and the works of revisionist Hollywood filmmakers such as George Lucas have contributed to a greater public understanding of cinema as a fluid medium instead of one that exists in a fixed form. The Phantom Edit (2000, a seminal fan edit based on Lucas's Star Wars Episode I: The Phantom Menace (1999, inspired new ranks of fan editors. However, critics have misunderstood fan edits as merely the work of disgruntled fans. In order to provide a critical and historical basis for studies in fan editing as a creative practice, I examine previous interpretations of fan edits in the context of relevant contemporary works, and I use an annotated chronology of The Phantom Edit to trace its influence on subsequent fan editing communities and uncover their relationship with intellectual property disputes.

  19. Duct having oscillatory side wall

    Science.gov (United States)

    Sprouse, Kenneth M.

    2018-04-03

    A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.

  20. The correlation between the dilated extent of bile duct and gallbladder and low bile duct obstructive jaundice diseases

    International Nuclear Information System (INIS)

    Wang Zhongqiu; Lu Guangming; Li Jieshou; Li Weiqin

    2005-01-01

    Objective: To evaluate the diagnostic value about the dilated extent of bile duct and gallbladder in low biliary obstructive diseases. Methods: CT and ERCP findings of 105 patients with low biliary obstructive disease were retrospectively analyzed. The dilated extent of intrahepatic and extra- hepatic bile duct and gallbladder were classified into seven types: Type I: severe dilatation of intrahepatic and extrahepatic bile duct and gallbladder; Type II: severe dilatation of extrahepatic bile duct and gallbladder and slight dilated intrahapetic bile duct; Type III: severe dilatation of intrahepatic and extrahepatic bile duct without or slight dilatation of gallbladder; Type IV: severe extrahepatic bile duct dilatation without or slight dilatation of intrahepatic bile duct and gallbladder; Type V: severe intrahepatic bile duct dilatation without or with slight dilatation of extrahepatic bile duct and gallbladder; Type VI: severe gallbladder dilatation without or with slight intrahepatic and extra- hepatic bile duct dilatation; Type VII: without or with slight dilatation of intrahepatic and extrahepatic bile duct and gallbladder. The biliary system dilated extent of low biliary obstructive disease on CT and ERCP were compared with results of clinical, operation, and pathology. Results: Thirty-three cases of tumor and 72 cases of non-tumor were proved by clinical and operation in 105 patients with low biliary obstructive disease. In 33 tumor patients, 16 patients were identified as Type I, 10 patients Type II, 4 patients Type III, 1 patient Type IV, 2 patients Type VII. In 72 non-tumor patients, 4 patients were identified as Type I, 4 patients Type II, 9 patients Type III, 33 patients Type IV, 2 patients Type V, 11 patients Type VI, 19 patients Type VII. A large difference between I, II type and III-VII type biliary dilatation existed in tumor and non-tumor group (χ 2 =47.33, P<0.01). Conclusion:Low obstructive biliary diseases are closely correlated with the dilated

  1. FANS-3D Users Guide (ESTEP Project ER 201031)

    Science.gov (United States)

    2016-08-01

    TECHNICAL DOCUMENT 3293 August 2016 FANS -3D User’s Guide (ESTEP Project ER-201031) Pei-Fang Wang SSC Pacific Hamn-Ching...1.1 THEORY AND NUMERICAL ALGORITHM OF FANS CODE ............................................. 1 2. FANS -3D SOFTWARE DOCUMENTATION AND EXECUTION...5 3. FANS -3D CODE PARALLELIZATION

  2. Long-term follow-up after choledochojejunostomy for bile duct stones with complex clearance of the bile duct

    NARCIS (Netherlands)

    Gouma, D. J.; Konsten, J.; Soeters, P. B.; Von Meyenfeldt, M.; Obertop, H.

    1989-01-01

    In this retrospective study, the long-term follow-up of patients undergoing choledochojejunostomy (Roux-en-Y) for bile duct stones with complex clearance of the bile duct is evaluated. Bile duct exploration and subsequent choledochojejunostomy (Roux-en-Y) was performed in 43 patients (median age 67

  3. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, B. [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-01

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  4. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, Robert [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, Bruce [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, Anthony [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, Ari [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-10

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  5. SNM holdup assessment of Los Alamos exhaust ducts

    International Nuclear Information System (INIS)

    Marshall, R.S.

    1994-02-01

    Fissile material holdup in glovebox and fume hood exhaust ducting has been quantified for all Los Alamos duct systems. Gamma-based, nondestructive measurements were used to quantify holdup. The measurements were performed during three measurement campaigns. The first campaign, Phase I, provided foot-by-foot, semiquantitative measurement data on all ducting. These data were used to identify ducting that required more accurate (quantitative) measurement. Of the 280 duct systems receiving Phase I measurements, 262 indicated less than 50 g of fissile holdup and 19 indicated fissile holdup of 50 or more grams. Seven duct systems were measured in a second campaign, called Series 1, Phase II. Holdup estimates on these ducts ranged from 421 g of 235 U in a duct servicing a shut-down uranium-machining facility to 39 g of 239 Pu in a duct servicing an active plutonium-processing facility. Measurements performed in the second campaign proved excessively laborious, so a third campaign was initiated that used more efficient instrumentation at some sacrifice in measurement quality. Holdup estimates for the 12 duct systems measured during this third campaign ranged from 70 g of 235 U in a duct servicing analytical laboratories to 1 g of 235 U and 1 g of 239 Pu in a duct carrying exhaust air to a remote filter building. These quantitative holdup estimates support the conclusion made at the completion of the Phase I measurements that only ducts servicing shut-down uranium operations contain about 400 g of fissile holdup. No ventilation ducts at Los Alamos contain sufficient fissile material holdup to present a criticality safety concern

  6. Single channel double-duct liquid metal electrical generator using a magnetohydrodynamic device

    Science.gov (United States)

    Haaland, Carsten M.; Deeds, W. Edward

    1999-01-01

    A single channel double-duct liquid metal electrical generator using a magnetohydrodynamic (MHD) device. The single channel device provides useful output AC electric energy. The generator includes a two-cylinder linear-piston engine which drives liquid metal in a single channel looped around one side of the MHD device to form a double-duct contra-flowing liquid metal MHD generator. A flow conduit network and drive mechanism are provided for moving liquid metal with an oscillating flow through a static magnetic field to produce useful AC electric energy at practical voltages and currents. Variable stroke is obtained by controlling the quantity of liquid metal in the channel. High efficiency is obtained over a wide range of frequency and power output.

  7. Gas turbine engine with supersonic compressor

    Science.gov (United States)

    Roberts, II, William Byron; Lawlor, Shawn P.

    2015-10-20

    A gas turbine engine having a compressor section using blades on a rotor to deliver a gas at supersonic conditions to a stator. The stator includes one or more of aerodynamic ducts that have converging and diverging portions for deceleration of the gas to subsonic conditions and to deliver a high pressure gas to combustors. The aerodynamic ducts include structures for changing the effective contraction ratio to enable starting even when designed for high pressure ratios, and structures for boundary layer control. In an embodiment, aerodynamic ducts are provided having an aspect ratio of two to one (2:1) or more, when viewed in cross-section orthogonal to flow direction at an entrance to the aerodynamic duct.

  8. Nasopalatine duct cyst: A case report

    Directory of Open Access Journals (Sweden)

    Saikrishna Pasupuleti

    2015-01-01

    Full Text Available Nasopalatine duct cyst (NPDC is the most common non-odontogenic cyst of oral cavity. Clinically, Nasopalatine duct cyst manifests as an asymptomatic swelling of the palate or the upper lip. Radiographically, it is seen as a heart-shaped radiolucency and can be confused with periapical pathology. The aim of this article is to report a case of a nasopalatine duct cyst in a 36-year-old patient which was misinterpreted for a periapical cyst. Diagnosis of a Nasopalatine duct cyst can be given through clinical, radiographical, and histopathological examination.

  9. 30 CFR 57.8534 - Shutdown or failure of auxiliary fans.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Shutdown or failure of auxiliary fans. 57.8534... Ventilation Underground Only § 57.8534 Shutdown or failure of auxiliary fans. (a) Auxiliary fans installed and... fan maintenance or fan adjustments where air quality is maintained in compliance with the applicable...

  10. Advanced thermal management of diesel engines; Neues Thermomanagement beim Dieselmotor

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, Wolfgang; Becker, Michael [BorgWarner, Ludwigsburg (Germany). Konzernvorentwicklung fuer Pkw-Antriebssysteme; Shutty, John [BorgWarner, Auburn Hills (United States). Regelung und Simulation in der Konzernvorentwicklung

    2013-05-01

    The potential of thermal management with respect to CO{sub 2} reduction is given by faster warm-up of engine and drivetrain, reduced losses from water pump and fan and finally the operation of the engine in an optimal temperature range. In a new approach, BorgWarner applies a variable coolant pump and a controlled coolant valve to a conventional cooling system. Both components, as well as the viscous fan clutch, are controlled by a newly developed controls approach.

  11. Radiologic imaging of bile duct changes by clonorchiasis

    International Nuclear Information System (INIS)

    Kim, Myung Joon; Yoo, Hyung Sik; Lee, Jong Tae; Jung, Soon Hee

    1988-01-01

    The changes of the bile ducts were reviewed retrospectively in 38 patients of clonorchiasis by ultrasonography and/or CT. Diagnosis was made in 13 patients by cholecystectomy and exploration of the common bile duct, another 2 patients by segmentectomy and wedge resection of the liver, and 23 patients by stool examination. 14 of 36 cases done ultrasonography showed the parallel channel sign, and small nodular echoes around the dilated bile ducts. And 3 cases showed the echoes of worm of clonorchis sinensis in the common bile duct. 22 of 36 cases showed the parallel channel signs only. All cases (11) done CT showed diffuse dilatation of the peripheral bile ducts. 5 of 11 cases showed ring or tubular contrast enhancement around the dilated bile ducts. In 2 cases of liver resection, the bile ducts showed adenomatous hyperplasia and severe periductal fibrosis. Proliferation of blood vessels and infiltration of inflammatory cells were also seen. So we consider that the increased echoes of the bile duct wall, small nodular echoes around the bile ducts were attributed to the bile duct dilatation, severe adenomatous hyperplasia and periductal fibrosis. The ring or tubular contrast enhancement of the dilated bile ducts seems to be caused by the marked periductal inflammation resulting in capillary proliferation and the periductal fibrosis.

  12. Radiologic imaging of bile duct changes by clonorchiasis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Joon; Yoo, Hyung Sik; Lee, Jong Tae; Jung, Soon Hee [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-10-15

    The changes of the bile ducts were reviewed retrospectively in 38 patients of clonorchiasis by ultrasonography and/or CT. Diagnosis was made in 13 patients by cholecystectomy and exploration of the common bile duct, another 2 patients by segmentectomy and wedge resection of the liver, and 23 patients by stool examination. 14 of 36 cases done ultrasonography showed the parallel channel sign, and small nodular echoes around the dilated bile ducts. And 3 cases showed the echoes of worm of clonorchis sinensis in the common bile duct. 22 of 36 cases showed the parallel channel signs only. All cases (11) done CT showed diffuse dilatation of the peripheral bile ducts. 5 of 11 cases showed ring or tubular contrast enhancement around the dilated bile ducts. In 2 cases of liver resection, the bile ducts showed adenomatous hyperplasia and severe periductal fibrosis. Proliferation of blood vessels and infiltration of inflammatory cells were also seen. So we consider that the increased echoes of the bile duct wall, small nodular echoes around the bile ducts were attributed to the bile duct dilatation, severe adenomatous hyperplasia and periductal fibrosis. The ring or tubular contrast enhancement of the dilated bile ducts seems to be caused by the marked periductal inflammation resulting in capillary proliferation and the periductal fibrosis.

  13. The influence of streamwise vortices on turbulent heat transfer in rectangular ducts with various aspect ratios

    International Nuclear Information System (INIS)

    Choi, Hang Seok; Park, Tae Seon

    2013-01-01

    Highlights: ► With changing aspect ratio, the effect of secondary flows on the turbulent heat transfer is scrutinized by a LES. ► The conditional sampling technique of instantaneous near-wall streamwise vortices is developed. ► Clockwise and counter-clockwise rotating streamwise vortices are sampled and discussed with the wall heat transfer. ► The hot-sweep motions of CW and CCW vortices clearly appear with increasing aspect ratio. -- Abstract: The effect of aspect ratio of rectangular duct on the turbulent flow and heat transfer is very important for its engineering applications. But the turbulent thermal fields have not been fundamentally scrutinized in spite of its engineering significance especially for cooling device. Hence, in the present study, large eddy simulation is applied to the turbulent flow and heat transfer in rectangular ducts with varying aspect ratio. The turbulent statistics of the flow and thermal quantities are calculated and the characteristics of wall Nusselt number are investigated for each rectangular duct. Especially, to scrutinize near-wall streamwise vortices, a conditional sampling technique is developed and adopted. Clockwise and counter-clockwise rotating streamwise vortices are sampled and the probability density function of the vortex circulation Reynolds number and wall Nusselt number are calculated. From the results, the time-averaged secondary flow caused by instantaneous vortical motions has a great effect on the heat and momentum transport of the flow in the rectangular ducts. Hence, the wall Nusselt number is enhanced near the downwash flow region of the secondary flow. However, with increasing the aspect ratio, the effects of the hot-sweep flow of the clockwise and counter-clockwise rotating vortices become equally dominant near the wall normal bisector of the ducts. During time averaging process, these two counter-rotating vortices are canceled out each other diminishing a secondary flow but they still enhance the

  14. Image reconstruction from multiple fan-beam projections

    International Nuclear Information System (INIS)

    Jelinek, J.; Overton, T.R.

    1984-01-01

    Special-purpose third-generation fan-beam CT systems can be greatly simplified by limiting the number of detectors, but this requires a different mode of data collection to provide a set of projections appropriate to the required spatial resolution in the reconstructed image. Repeated rotation of the source-detector fan, combined with shift of the detector array and perhaps offset of the source with respect to the fan's axis after each 360 0 rotation(cycle), provides a fairly general pattern of projection space filling. The authors' investigated the problem of optimal data-collection geometry for a multiple-rotation fan-beam scanner and of corresponding reconstruction algorithm

  15. NASA ISS Portable Fan Assembly Acoustics

    Science.gov (United States)

    Boone, Andrew; Allen, Christopher S.; Hess, Linda F.

    2018-01-01

    The Portable Fan Assembly (PFA) is a variable speed fan that can be used to provide additional ventilation inside International Space Station (ISS) modules as needed for crew comfort or for enhanced mixing of the ISS atmosphere. This fan can also be configured with a Shuttle era lithium hydroxide (LiOH) canister for CO2 removal in confined areas partially of fully isolated from the primary Environmental Control and Life Support System (ECLSS) on ISS which is responsible for CO2 removal. This report documents noise emission levels of the PFA at various speed settings and configurations. It also documents the acoustic attenuation effects realized when circulating air through the PFA inlet and outlet mufflers and when operating in its CO2 removal configuration (CRK) with a LiOH canister (sorbent bed) installed over the fan outlet.

  16. Fan relationship management in football - going beyond traditional product offerings to win the hearts of fans

    DEFF Research Database (Denmark)

    Cortsen, Kenneth

    2015-01-01

    The management and control of fan relations should go beyond a football club’s traditional product and service offerings and touch the important experiential side of the football economy. This will create a stronger platform to optimize ROI, ROE and ROO relating to different fan segments....

  17. Dynamic and Implications of Football Fans' Club and Fans ...

    African Journals Online (AJOL)

    DrNneka

    As spectator in football game for example, human beings are known to fragment into fans groups. ..... since respondents identified performance as the main motivating factor in their selection of supporting teams ... directional. They are supports ...

  18. Potential disturbance interactions with a single IGV in an F109 turbofan engine

    Science.gov (United States)

    Kirk, Joel F.

    A common cause of aircraft engine failure is the high cycle fatigue of engine blades and stators. One of the primary causes of these failures is due to blade row interactions, which cause an aerodynamic excitation to be resonant with a mechanical natural frequency. Traditionally, the primary source of such aerodynamic excitations has been practically limited to viscous wakes from upstream components. However, more advanced designs require that blade rows be very highly loaded and closely spaced. This results in aerodynamic excitation from potential fields of down stream engine components, in addition to the known wake excitations. An experimental investigation of the potential field from the fan of a Honeywell F109 turbofan engine has been completed. The investigation included velocity measurements upstream of the fan, addition of an airfoil shaped probe upstream of the fan on which surface pressure measurements were acquired, and measurement of the velocity in the interaction region between the probe and the fan. This investigation sought to characterize the response on the upstream probe due to the fan potential field and the interaction between a viscous wake and the potential field; as such, all test conditions were for subsonic fan speeds. The results from the collected data show that fan-induced potential disturbances propagate upstream at acoustic velocities, to produce vane surface-pressure amplitudes as high as 40 percent Joel F. Kirk of the inlet, mean total pressure. Further, these fan-induced pressure amplitudes display large variations between the two vane surfaces. An argument is made that the structure of the pressure response is consistent with the presence of two distinct sources of unsteady forcing disturbances. The disturbances on the incoming-rotation-facing surface of the IGV propagated upstream at a different speed than those on the outgoing-rotation-facing surface, indicating that one originated from a rotating source and the other from a

  19. Effect of duct geometry on Wells turbine performance

    International Nuclear Information System (INIS)

    Shaaban, S.; Abdel Hafiz, A.

    2012-01-01

    Highlights: ► A Wells turbine duct design in the form of venturi duct is proposed and investigated. ► Optimum duct geometry is identified. ► Up to 14% increase of the turbine power can be achieved using the optimized duct geometry. ► Up to 9% improve of the turbine efficiency is attained by optimizing the turbine duct geometry. ► The optimized duct geometry results in tangible delay of the turbine stalling point. - Abstract: Wells turbines can represent important source of renewable energy for many countries. An essential disadvantage of Wells turbines is their low aerodynamic efficiency and consequently low power produced. In order to enhance the Wells turbine performance, the present research work proposes the use of a symmetrical duct in the form of a venturi tube with turbine rotor located at throat. The effects of duct area ratio and duct angle are investigated in order to optimize Wells turbine performance. The turbine performance is numerically investigated by solving the steady 3D incompressible Reynolds Averaged Navier–Stocks equation (RANS). A substantial improve of the turbine performance is achieved by optimizing the duct geometry. Increasing both the duct area ratio and duct angle increase the acceleration and deceleration upstream and downstream the rotor respectively. The accelerating flow with thinner boundary layer thickness upstream the rotor reduces the flow separation on the rotor suction side. The downstream diffuser reduces the interaction between tip leakage flow and blade suction side. Up to 14% increase in turbine power and 9% increase in turbine efficiency are achieved by optimizing the duct geometry. On other hand, a tangible delay of the turbine stall point is also detected.

  20. Review: Bettina Fritzsche (2003. Pop-Fans. Studie einer Mädchenkultur [Pop-Fans: Study of a Girl Culture

    Directory of Open Access Journals (Sweden)

    Lothar Mikos

    2006-05-01

    Full Text Available This study focuses on the "girl culture" created by fans of boy groups and girl groups. The central case study is used to examine fan practices as cultural practices using reconstructive and documentary methodologies, and to assess the normative demands placed on young people. The study centers on the question of gender socialization by mediated symbolic resources, and shows that fan culture is a self-determined space in which girls can negotiate normative demands and engage with questions of gender, sexuality and the body, testing conformity and obstinacy. Fan activities are presented as part of the self-empowerment of girls. The study makes an important contribution to the research of a specific girl culture. It shows in a brilliant way how media representations are used as symbolic material in everyday cultural practices. URN: urn:nbn:de:0114-fqs0603187

  1. 30 CFR 75.310 - Installation of main mine fans.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Installation of main mine fans. 75.310 Section... mine fans. (a) Each main mine fan shall be— (1) Installed on the surface in an incombustible housing... that gives a signal at the mine when the fan either slows or stops. A responsible person designated by...

  2. K-pop Reception and Participatory Fan Culture in Austria

    Directory of Open Access Journals (Sweden)

    Sang-Yeon Sung

    2013-12-01

    Full Text Available K-pop’s popularity and its participatory fan culture have expanded beyond Asia and become significant in Europe in the past few years. After South Korean pop singer Psy’s “Gangnam Style” music video topped the Austrian chart in October 2012, the number and size of K-pop events in Austria sharply increased, with fans organizing various participatory events, including K-pop auditions, dance festivals, club meetings, quiz competitions, dance workshops, and smaller fan-culture gatherings. In the private sector, longtime fans have transitioned from participants to providers, and in the public sector, from observers to sponsors. Through in-depth interviews with event organizers, sponsors, and fans, this article offers an ethnographic study of the reception of K-pop in Europe that takes into consideration local interactions between fans and Korean sponsors, perspectives on the genre, patterns of social integration, and histories. As a case study, this research stresses the local situatedness of K-pop fan culture by arguing that local private and public sponsors and fans make the reception of K-pop different in each locality. By exploring local scenes of K-pop reception and fan culture, the article demonstrates the rapidly growing consumption of K-pop among Europeans and stresses multidirectional understandings of globalization.

  3. Plate-fin array cooling using a finger-like piezoelectric fan

    International Nuclear Information System (INIS)

    Shyu, Jin-Cherng; Syu, Jhih-Zong

    2014-01-01

    In this study, the heat transfer of a plate-fin array cooled by a vibrating finger-like piezoelectric fan comprising four flexible rectangular blades was investigated. The results indicated that the heat transfer enhancement of the fin array cooled by a vibrating piezoelectric fan at x/L = 0.5 and H = 5 mm ranged between 1.5 and 3.3, regardless of the fin array orientation. However, the heat transfer enhancement caused by a fan being placed at either edge of the fin array yielded a dissimilar result between both of the fin array orientations because of the superimposed effects of the boundary layer development and the air flow induced by the fan. This dissimilarity was especially noticeable when the piezoelectric fan was composed of aluminum blades to accommodate the moderate Reynolds number. In addition to the Reynolds number, the ratio of the fan blade vibration envelope to the source area determined the Nu number of the piezoelectric fan-cooled fin array. This design enhanced the fin array heat transfer and reduced cooler volume by embedding multiple vibrating beams into the fin array. -- Highlights: • Heat transfer of a piezoelectric fan-cooled plate-fin array was investigated. • Effects of fan position, fan height and fan material on heat transfer were examined. • Similar heat transfer enhancement range was shown for both fin array orientations. • Fin heat transfer with a running Al fan at x = 0 was higher than that at x = 0.25L. • Besides fan Reynolds number, the area ratio also determined Nu of the fin array

  4. "Emotions-Only" versus "Special People": Genre in fan discourse

    Directory of Open Access Journals (Sweden)

    Louisa Ellen Stein

    2008-09-01

    Full Text Available This essay looks at genre as a complex set of discursive threads running unevenly through production, TV text, and fan reception. Through a case study of the reception of fan favorite Roswell, this essay interrogates the role of genre in spectatorship. In its mixing of teen and science fiction elements, Roswell trod upon contested generic spaces, eliciting strong reaction from its viewers. Connections between genre and gender came to the fore, as producer commentary linked science fiction with male audiences and teen romance with female audiences. Fans responded with analyses that greatly complicated and at times overtly rejected industrial suppositions regarding the gendered work of genre. Through these fan conversations, we can witness the complexity of genre as discursive thread moving through not only TV texts but also multivariant fan responses. I intend this essay to work at two levels. My analysis of fan responses to Roswell models the possibilities of a close study of genre discourse. At the same time, my case study probes the nature of genre in fan engagement, as genre discourses intersect with other fan concerns such as character identification, perceptions of textual quality, and questions of gender representation. While we cannot necessarily look to fan accounts for proof of how viewers engage with genre, they do tell us how fans frame their engagement with genre, how they incorporate genre into their performance of fannishness, and how they perform and thus enact genre itself as a shared cultural process.

  5. Fan filmmaking and copyright in a global world: Warhammer 40,000 fan films and the case of Damnatus

    Directory of Open Access Journals (Sweden)

    John Walliss

    2010-09-01

    Full Text Available The last decade has witnessed a proliferation, both online and off-line, of films produced by amateurs inspired by mainstream films, TV shows, and novels. As with much other fan production, fan films exist in, at best, a legally gray area since they are produced by amateurs, rather than by the media companies that own the copyrights to the films and novels that provide both their inspiration and settings. I examine the phenomenon of fan filmmaking, focusing on films produced by fans of the Warhammer 40,000 (W40K tabletop battle game. In particular, I examine the case of Damnatus: The Enemy Within (Damnatus: Feind Im Innern, 2005, a German-made fan film set in the W40K universe, which was banned from release by the game's rights holder, the UK company Games Workshop, in 2007. Damnatus offers an interesting case study in both the ongoing struggle between rights holders and textual poachers and the tensions that can exist between different legal understandings of copyright in an increasingly globalized world.

  6. Rating behavior of football fans by Internet

    Directory of Open Access Journals (Sweden)

    Dawid Szczygielski

    2017-02-01

    Full Text Available The aim of this article was to present the opinion of Internet users for football fans and their behavior. The research method was used diagnostic survey research in the form of a survey computer. 102 people were tested mostly in the age of 21-25 years. The research can draw the following conclusions: (1 Football stadiums should be better secured and protected by the relevant departments, (2 The colors and club merchandise is not a reliable indicator of fan devotion of his team, (3 These are the fans, the fans are cheering for is a sacred thing, (4 All acts of devastation to property and vandalism in football stadiums should be severely punished.

  7. c-fans and Newton polyhedra of algebraic varieties

    International Nuclear Information System (INIS)

    Kazarnovskii, B Ya

    2003-01-01

    To every algebraic subvariety of a complex torus there corresponds a Euclidean geometric object called a c-fan. This correspondence determines an intersection theory for algebraic varieties. c-fans form a graded commutative algebra with visually defined operations. The c-fans of algebraic varieties lie in the subring of rational c-fans. It seems that other subrings may be used to construct an intersection theory for other categories of analytic varieties. We discover a relation between an old problem in the theory of convex bodies (the so-called Minkowski problem) and the ring of c-fans. This enables us to define a correspondence that sends any algebraic curve to a convex polyhedron in the space of characters of the torus

  8. Source of marine turbidites on the Andaman-Nicobar Islands: Nicobar Fan, Bengal Fan or paleo-Irrawaddy?

    Science.gov (United States)

    Carter, A.

    2017-12-01

    Marine turbidites from an axially fed submarine fan are intermittently exposed across the entire chain of the Andaman-Nicobar Islands. Known as the Andaman Flysch (AF) and loosely assigned to the Paleogene, it has been proposed that these rocks are sourced from the Himalaya and thus provide a unique window into early stages of orogenesis. Where the turbidites came from has been subject to debate; they are either Bengal Fan or forearc deposits cut off from the Bengal Fan and possibly sourced from the Irrawaddy delta. Following recent IODP drilling in the eastern Indian Ocean (Expeditions 354 and 362) it is now possible resolve this by comparing the provenance of AF turbidites with the Bengal and Nicobar Fans. The Andaman Flysch can be traced as detached outcrops all along the western side of the main islands of Andaman over a strike length of more than 200 km. Exposures along the east coast are confined to South Andaman Island. Petrographic and geochemical data show a common continental crust signal with minor contributions from arc material. But, there are also differences whereby west coast sandstones show significantly higher quartz content and less feldspars and rock fragments. Staurolite is also present in all samples from the western side, but is absent from east coast samples. Both detrital zircon U-Pb and Bulk rock Nd data record the presence of arc material likely from Myanmar. Detrital zircon data from the Nicobar Fan match the Andaman turbidites and indicate sources from the Greater and Tethyan Himalaya mixed with sediment from the Burmese arc. Transfer of Irrawaddy derived sediment to the Nicobar Fan is ruled out as sediment transfer across the fore-arc to the west was restricted by the then exposed Yadana and M8 highs in the north and the Sewell and Alcock Rises to the south. Sediment isopachs of the Martaban back arc basin, the main north-south-oriented depocentre in the Andaman Sea related to the development of the Thanlwin -Irrawaddy delta system

  9. Health Assessment of Cooling Fan Bearings Using Wavelet-Based Filtering

    Directory of Open Access Journals (Sweden)

    Qiang Miao

    2012-12-01

    Full Text Available As commonly used forced convection air cooling devices in electronics, cooling fans are crucial for guaranteeing the reliability of electronic systems. In a cooling fan assembly, fan bearing failure is a major failure mode that causes excessive vibration, noise, reduction in rotation speed, locked rotor, failure to start, and other problems; therefore, it is necessary to conduct research on the health assessment of cooling fan bearings. This paper presents a vibration-based fan bearing health evaluation method using comblet filtering and exponentially weighted moving average. A new health condition indicator (HCI for fan bearing degradation assessment is proposed. In order to collect the vibration data for validation of the proposed method, a cooling fan accelerated life test was conducted to simulate the lubricant starvation of fan bearings. A comparison between the proposed method and methods in previous studies (i.e., root mean square, kurtosis, and fault growth parameter was carried out to assess the performance of the HCI. The analysis results suggest that the HCI can identify incipient fan bearing failures and describe the bearing degradation process. Overall, the work presented in this paper provides a promising method for fan bearing health evaluation and prognosis.

  10. Numerical Aerodynamic Evaluation and Noise Investigation of a Bladeless Fan

    OpenAIRE

    mohammad jafari; Hossein Afshin; Bijan Farhanieh; Hamidreza bozorgasareh

    2015-01-01

    Bladeless fan is a novel fan type that has no observable impeller, usually used for domestic applications. Numerical investigation of a Bladeless fan via Finite Volume Method was carried out in this study. The fan was placed in center of a 4×2×2m room and 473 Eppler airfoil profile was used as cross section of the fan. Performance and noise level of the fan by solving continuity and momentum equations as well as noise equations of Broadband Noise Source (BNS) and Ffowcs Williams a...

  11. Advanced Subsonic Technology (AST) 22-Inch Low Noise Research Fan Rig Preliminary Design of ADP-Type Fan 3

    Science.gov (United States)

    Jeracki, Robert J. (Technical Monitor); Topol, David A.; Ingram, Clint L.; Larkin, Michael J.; Roche, Charles H.; Thulin, Robert D.

    2004-01-01

    This report presents results of the work completed on the preliminary design of Fan 3 of NASA s 22-inch Fan Low Noise Research project. Fan 3 was intended to build on the experience gained from Fans 1 and 2 by demonstrating noise reduction technology that surpasses 1992 levels by 6 dB. The work was performed as part of NASA s Advanced Subsonic Technology (AST) program. Work on this task was conducted in the areas of CFD code validation, acoustic prediction and validation, rotor parametric studies, and fan exit guide vane (FEGV) studies up to the time when a NASA decision was made to cancel the design, fabrication and testing phases of the work. The scope of the program changed accordingly to concentrate on two subtasks: (1) Rig data analysis and CFD code validation and (2) Fan and FEGV optimization studies. The results of the CFD code validation work showed that this tool predicts 3D flowfield features well from the blade trailing edge to about a chord downstream. The CFD tool loses accuracy as the distance from the trailing edge increases beyond a blade chord. The comparisons of noise predictions to rig test data showed that both the tone noise tool and the broadband noise tool demonstrated reasonable agreement with the data to the degree that these tools can reliably be used for design work. The section on rig airflow and inlet separation analysis describes the method used to determine total fan airflow, shows the good agreement of predicted boundary layer profiles to measured profiles, and shows separation angles of attack ranging from 29.5 to 27deg for the range of airflows tested. The results of the rotor parametric studies were significant in leading to the decision not to pursue a new rotor design for Fan 3 and resulted in recommendations to concentrate efforts on FEGV stator designs. The ensuing parametric study on FEGV designs showed the potential for 8 to 10 EPNdB noise reduction relative to the baseline.

  12. 14 CFR 33.27 - Turbine, compressor, fan, and turbosupercharger rotors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turbine, compressor, fan, and... Turbine, compressor, fan, and turbosupercharger rotors. (a) Turbine, compressor, fan, and... affect turbine, compressor, fan, and turbosupercharger rotor structural integrity will not be exceeded in...

  13. More air performance, enhanced energy efficiency. Plug Fans fit for the future; Mehr Luftleistung, hohe Energieeffizienz. Plug Fans fit fuer die Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    Sigloch, Uwe; Muehleck, Ralf [ebm-papst, Mulfingen (Germany); Reiff, Ellen-Christine [Redaktionsbuero, Stutensee (Germany)

    2011-08-15

    The ErP directive 2009/125/EC demands a design of products for the European market according to pre-defined performance criteria. All fans with a performance between 125 W and 500 kW are affected by this directive. Ebm-papst Mulfingen GmbH and Co. KG (Mulfingen, Federal Republic of Germany) has developed and expanded the fan series Plug fans with Greentech EC technology in order to cover even higher air output ranges. Straight in the air technology and air conditioning systems a great potential of energy saving can be deduced with these fans. It is precisely in this area, the fans are operated with a long duty cycle.

  14. ITER L 6 equatorial maintenance duct remote handling study

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The status and conclusions of a preliminary study of equatorial maintenance duct remote handling is reported. Due to issues with the original duct design a significant portion of the study had to be refocused on equatorial duct layout studies. The study gives an overview of some of the options for design of these ducts and the impact of the design on the equipment to work in the duct. To develop a remote handling concept for creating access through the ducts the following design tasks should be performed: define the operations sequences for equatorial maintenance duct opening and closing; review the remote handling requirements for equatorial maintenance duct opening and closing; design concept for door and pipe handling equipment and to propose preliminary procedures for material handling outsides the duct. 35 figs

  15. CFD Models of a Serpentine Inlet, Fan, and Nozzle

    Science.gov (United States)

    Chima, R. V.; Arend, D. J.; Castner, R. S.; Slater, J. W.; Truax, P. P.

    2010-01-01

    Several computational fluid dynamics (CFD) codes were used to analyze the Versatile Integrated Inlet Propulsion Aerodynamics Rig (VIIPAR) located at NASA Glenn Research Center. The rig consists of a serpentine inlet, a rake assembly, inlet guide vanes, a 12-in. diameter tip-turbine driven fan stage, exit rakes or probes, and an exhaust nozzle with a translating centerbody. The analyses were done to develop computational capabilities for modeling inlet/fan interaction and to help interpret experimental data. Three-dimensional Reynolds averaged Navier-Stokes (RANS) calculations of the fan stage were used to predict the operating line of the stage, the effects of leakage from the turbine stream, and the effects of inlet guide vane (IGV) setting angle. Coupled axisymmetric calculations of a bellmouth, fan, and nozzle were used to develop techniques for coupling codes together and to investigate possible effects of the nozzle on the fan. RANS calculations of the serpentine inlet were coupled to Euler calculations of the fan to investigate the complete inlet/fan system. Computed wall static pressures along the inlet centerline agreed reasonably well with experimental data but computed total pressures at the aerodynamic interface plane (AIP) showed significant differences from the data. Inlet distortion was shown to reduce the fan corrected flow and pressure ratio, and was not completely eliminated by passage through the fan

  16. Spectral measurements of gamma radiation streaming through ducts

    International Nuclear Information System (INIS)

    Meenakshisundaram, P.K.; Bhatnagar, V.M.; Raghunath, V.M.; Gopinath, D.V.

    1979-01-01

    The paper presents the spectral measurements of gamma radiation streaming through multi-legged rectangular concrete ducts for cesium-137 and cobald-60 sources. Effect of lead lining the inner surface of the duct on the streaming radiation spectrum and optimization of liner thickness for minimum streaming radiation dose have been studied. For three-legged ducts, a comparative analysis of lead lining the entire duct as against lining any one or both the corners of the duct is reported. It is seen that lead lining any one of the corners would reduce the streaming radiation dose by a factor of 5 to 12. Lining both the corners which is nearly as effective as lining the entire duct reduces the dose by a factor of 16 to 60 depending on the soruce energy and duct dimensions. (orig.)

  17. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D.; McIlvaine , J.; Fonorow, K.; Martin, E.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition to enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.

  18. 16 CFR 305.13 - Labeling for ceiling fans.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Labeling for ceiling fans. 305.13 Section... Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a ceiling fan shall be labeled clearly and conspicuously on the principal display panel with the following...

  19. 76 FR 50739 - Hung Ta Fan: Debarment Order

    Science.gov (United States)

    2011-08-16

    ...] Hung Ta Fan: Debarment Order AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The... (the FD&C Act) debarring Hung Ta Fan for a period of 5 years from importing articles of food or.... Fan was convicted of a felony under Federal law for conduct relating to the importation into the...

  20. 30 CFR 75.311 - Main mine fan operation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main mine fan operation. 75.311 Section 75.311... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.311 Main mine fan operation. (a) Main mine fans shall be continuously operated, except as otherwise approved in the ventilation plan, or when...

  1. PLSS 2.5 Fan Design and Development

    Science.gov (United States)

    Quinn, Gregory; Carra, Michael; Converse, David; Chullen, Cinda

    2015-01-01

    NASA is building a high fidelity prototype of an advanced portable life support system (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge in order to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, is driven by a centrifugal fan developed using specifications from the Constellation Program. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement have been identified with the existing fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5.

  2. Financial Aspects of Bile Duct Injuries.

    Science.gov (United States)

    Palaz Alı, Ozgkıour; Ibis, Abdil Cem; Gurtekin, Basak

    2017-11-04

    BACKGROUND Major bile duct injury is the most worrisome complication of cholecystectomy. There is no detailed data about the incidence or treatment-related costs of bile duct injuries in Turkey. We aimed to determine prevalence and therapeutic costs of patients with major biliary duct injuries managed in our department, and further estimate a projection of these parameters at the national level. MATERIAL AND METHODS All patients admitted due to bile duct injury during cholecystectomy from 2011 to 2014 were included. Healthcare costs were calculated by summing of their all treatment-related costs in Istanbul Medical Faculty. We collected 2014-2015 data on number of patients diagnosed with cholecystitis in Turkey, the number of cholecystectomies, and the number of the interventions performed following these initial surgeries, which were obtained from the Turkish Social Security Institution. RESULTS Forty-nine patients were enrolled and bilioenteric diversion was performed in 39 patients: 20.4% of patients had Bismuth II, 38.8% had Bismuth III, and 40.8% had Bismuth IV biliary stricture. Comparison of stricture types with total costs, days of hospitalization, and outpatient clinic costs revealed significant differences. Mean total cost of corrective surgeries was 9199 TRY. We estimated that 1.5% to 2.4% of patients who underwent cholecystectomy in Turkey have bile duct injury (including 0.3% with major bile duct injury). CONCLUSIONS New preventive strategies should be used to avoid bile duct injuries, which have a huge financial impact on the national economy.

  3. Efficient, Low Pressure Ratio Propulsor for Gas Turbine Engines

    Science.gov (United States)

    Gallagher, Edward J. (Inventor); Monzon, Byron R. (Inventor)

    2018-01-01

    A gas turbine engine includes a bypass flow passage that has an inlet and defines a bypass ratio in a range of approximately 8.5 to 13.5. A fan is arranged within the bypass flow passage. A first turbine is a 5-stage turbine and is coupled with a first shaft, which is coupled with the fan. A first compressor is coupled with the first shaft and is a 3-stage compressor. A second turbine is coupled with a second shaft and is a 2-stage turbine. The fan includes a row of fan blades that extend from a hub. The row includes a number (N) of the fan blades, a solidity value (R) at tips of the fab blades, and a ratio of N/R that is from 14 to 16.

  4. An Alluvial Fan at Apollinaris Patera, Mars

    OpenAIRE

    Ghail, RC; Hutchison, JE

    2003-01-01

    Apollinaris Patera, Mars (7?S,173?E), is an intermediate sized volcano (~6 km high, 150 km diameter) with a large (200-km long) fan-like deposit on its southern flank. This fan is deeply incised and originates from a single breach in the rim of the summit caldera. New topographic and multispectral image data reveal that this fan is alluvial, implying a long-lived source of (volcaniclastic) sediment and water (probably from a caldera lake).

  5. On Some Generalized Ky Fan Minimax Inequalities

    Directory of Open Access Journals (Sweden)

    Xianqiang Luo

    2009-01-01

    Full Text Available Some generalized Ky Fan minimax inequalities for vector-valued mappings are established by applying the classical Browder fixed point theorem and the Kakutani-Fan-Glicksberg fixed point theorem.

  6. The modern Kaoping transient fan offshore SW Taiwan: Morphotectonics and development

    Science.gov (United States)

    Hsiung, Kan-Hsi; Yu, Ho-Shing; Chiang, Cheng-Shing

    2018-01-01

    Using bathymetry and seismic reflection profiles, this study examined and determined the transient nature of the Kaoping Fan located in the topographically complex slope offshore southwest Taiwan. Kaoping Fan is located west of the lower reach of the Kaoping Canyon at the lower Kaoping Slope, ranging from 2,200 to 3,000 m water depth, and has a relatively small areal extent restricted in the topographic lows confined by structural highs due to mud diapiric uplifting and thrust faulting. Kaoping Fan shows an asymmetrical triangular fan-shaped bathymetric feature elongated in an NW-SE direction but with a strong skew toward the east. The fan deposits consist of three main seismic facies: layered high-amplitude reflections in the upper section and stratified, parallel to sub-parallel low-amplitude reflections with variable continuity and channel fill facies in the lower section. In the absence of ground-truthing from core data, the seismic patterns suggest that the Kaoping Fan recorded the onset of channelized and over-bank deposits in the lower part and layered turbidite facies in the upper part subsequently. The development of the Kaoping Fan can be divided into three stages in terms of canyon activities and fan-feeding processes. Initially, Kaoping Fan was mainly fed by a point sediment source at the apex of the fan. Secondly, Kaoping Fan was maintained as a slope fan, mainly fed laterally by over-spilled sediments from the canyon. Finally, the Kaoping Canyon completely passes through the Kaoping Fan and supplies over-spilled sediments laterally, forming a transient fan with canyon incision and sediment by-passing. The accumulation of sediments and the growth of Kaoping Fan are primarily controlled by inherited complex paleo-topography and the evolution of Kaoping Canyon. The sediment delivery system of Kaoping Fan is characterized by lateral supply of over-spilling sediment flows and sediments bypassing to and beyond the base of slope. The Kaoping Fan together

  7. Optimizing condenser fan control for air-cooled centrifugal chillers

    Energy Technology Data Exchange (ETDEWEB)

    Yu, F.W.; Chan, K.T. [Dept. of Building Services Engineering, The Hong Kong Polytechnic Univ., Hung Hom, Hong Kong (China)

    2008-07-15

    The current design and operation of air-cooled condensers can cause a significant decrease in chiller performance under part load conditions. This paper demonstrates optimal condenser fan control to improve the coefficient of performance (COP) of air-cooled chillers. This control involves identifying the optimum set point of condensing temperature with the optimized power relationships of the compressors and condenser fans and enhancing the airflow and heat transfer area of the condensers. An example application of this control for an air-cooled centrifugal chiller indicated that the COP could increase by 11.4-237.2%, depending on the operating conditions. Such the increase of the COP results in a reduction of up to 14.1 kWh/m{sup 2}, or 27.3% in the annual electricity consumption per unit A/C floor area of chillers, given that the chillers serve an office building requiring an annual cooling energy per unit A/C floor area of 173.3 kWh/m{sup 2}. The simulation results of this study will give HVAC engineers a better understanding of how to optimize the design and operation of air-cooled chillers. (author)

  8. Vitellointestinal Duct Anomalies in Infancy.

    Science.gov (United States)

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5-9 of intrauterine life. This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality.

  9. Cholangiographic evaluation of bile duct carcinoma

    International Nuclear Information System (INIS)

    Nichols, D.A.; MacCarty, R.L.; Gaffey, T.A.

    1983-01-01

    Cholangiograms and clinical histories of 82 patients with biopsy-proved bile duct carcinoma were reviewed. The carcinomas were classified according to morphologic findings and clinical outcome. Ulcerative colitis and antecedent inflammatory disease of the biliary tree, particularly primary sclerosing cholangitis, seem to predispose to the development of bile duct carcinoma. Focal stenotic lesions were the most common morphologic type (62/82). Polypoid carcinomas and diffuse sclerosing carcinomas were less common and of about equal frequency. Prognosis was best for patients with polypoid carcinomas and worst for those with diffuse sclerosing carcinomas. In 69 cases (84%), the tumors involved the intrahepatic or proximal extrahepatic ducts, makin curative resection difficult or impossible. Patients with carcinomas limited to the more distal extrahepatic bile ducts had a longer average survival and a higher probability of surgical cure. Proper management of patients with bile duct carcinoma requires a complete and accurate cholangiographic evaluation of the morphology, location, and extent of the disease

  10. Analysis and simulation on two types of thrust reversers in an aircraft engine

    Directory of Open Access Journals (Sweden)

    Tian Feng

    2017-01-01

    Full Text Available With rapid development of new composite material and manufacturing, innovative engineering solutions are supplied to the advanced nacelle, such as integrated propulsion system(IPS, carbon-fiber composite inner skin by single-piece molding process,which offers a reduction in fuel burn and less noise produced by engines. The advanced nacelle has an O-duct thrust reverser demonstrator whose composite structure is in the form of an “O” as opposed to the traditional “D-duct”. A comparative study is to be conducted to investigate the differences between the latest O-duct and conventional D-duct in numerical approaches. To focus on the quantitative analysis of thrust reverser’s operation, this paper mainly uses CATIA/Digital Mock Up(DMU to simulate under deployment and stowed conditions of two different thrust reverser. After comparing the structural weight, the design models of blocker door are built for kinematic analysis of relevant mechanism and simulation. The results show that simplified design and elimination of multiple interfaces generates weight saving, O-duct improves airflows within the engine, meanwhile D-duct has excellent cost effective and maintainability.

  11. Numerical Study of Aeroacoustic Sound on Performance of Bladeless Fan

    Science.gov (United States)

    Jafari, Mohammad; Sojoudi, Atta; Hafezisefat, Parinaz

    2017-03-01

    Aeroacoustic performance of fans is essential due to their widespread application. Therefore, the original aim of this paper is to evaluate the generated noise owing to different geometric parameters. In current study, effect of five geometric parameters was investigated on well performance of a Bladeless fan. Airflow through this fan was analyzed simulating a Bladeless fan within a 2 m×2 m×4 m room. Analysis of the flow field inside the fan and evaluating its performance were obtained by solving conservations of mass and momentum equations for aerodynamic investigations and FW-H noise equations for aeroacoustic analysis. In order to design Bladeless fan Eppler 473 airfoil profile was used as the cross section of this fan. Five distinct parameters, namely height of cross section of the fan, outlet angle of the flow relative to the fan axis, thickness of airflow outlet slit, hydraulic diameter and aspect ratio for circular and quadratic cross sections were considered. Validating acoustic code results, we compared numerical solution of FW-H noise equations for NACA0012 with experimental results. FW-H model was selected to predict the noise generated by the Bladeless fan as the numerical results indicated a good agreement with experimental ones for NACA0012. To validate 3-D numerical results, the experimental results of a round jet showed good agreement with those simulation data. In order to indicate the effect of each mentioned parameter on the fan performance, SPL and OASPL diagrams were illustrated.

  12. Effects of bending-torsional duct-induced swirl distortion on aerodynamic performance of a centrifugal compressor

    Science.gov (United States)

    Hou, Hongjuan; Wang, Leilei; Wang, Rui; Yang, Yanzhao

    2017-04-01

    A turbocharger compressor working in commercial vehicles, especially in some passenger cars, often works together with some pipes with complicated geometry as an air intake system, due to limit of available space in internal combustion engine compartments. These pipes may generate various distortions of physical parameters of the air at the inlet of the compressor and therefore the compressor aerodynamic performance deteriorates. Sometimes, the turbocharging engine fails to work at some operation points. This paper investigates the effects of various swirl distortions induced by different bending-torsional intake ducts on the aerodynamic performance of a turbocharger compressor by both 3D numerical simulations and experimental measurements. It was found that at the outlet of the pipes the different inlet ducts can generate different swirl distortions, twin vortices and bulk-like vortices with different rotating directions. Among them, the bulk-like vortices not only affect seriously the pressure distribution in the impeller domain, but also significantly deteriorate the compressor performance, especially at high flow rate region. And the rotating direction of the bulk-like vortices is also closely associated with the efficiency penalty. Besides the efficiency, the transient flow rate through a single impeller channel, or the asymmetric mass flow crossing the whole impeller, can be influenced by two disturbances. One is from the upstream bending-torsional ducts; other one is from the downstream volute.

  13. CFD Validation and Flow Control of RAE-M2129 S-Duct Diffuser Using CREATETM-AV Kestrel Simulation Tools

    Directory of Open Access Journals (Sweden)

    Pooneh Aref

    2018-03-01

    Full Text Available The flow physics modeling and validation of the Royal Aircraft Establishment (RAE subsonic intake Model 2129 (M2129 are presented. This intake has an 18 inches long S duct with a 5.4 inches offset, an external and an internal lip, forward and rear extended ducts, and a center-positioned bullet before the outlet. Steady-state and unsteady experimental data are available for this duct. The measurements include engine face conditions (pressure recovery, static pressure to free-stream total pressure ratio, and distortion coefficient at the worst 60 ∘ sector or DC60, as well as wall static pressure data along the duct. The intake has been modeled with HPCMP CREATE TM -AV Kestrel simulation tools. The validation results are presented including the effects of turbulence models on predictions. In general, very good agreement (difference errors are less than 6% was found between predictions and measurements. Secondary flow at the first bend and a region of flow separation are predicted at the starboard wall with an averaged DC60 coefficient of 0.2945 at the engine face. Next, a passive and an active flow control method are computationally investigated. The passive one uses vane-type vortex generators and the active one has synthetic jet actuators. The results show that considered passive and active flow control methods reduce the distortion coefficient at the engine face and the worst 60 ∘ sector to 0.1361 and 0.0881, respectively. The flow control performance trends agree with those obtained in experiments as well. These results give confidence to apply the Kestrel simulation tools for the intake design studies of new and unconventional vehicles and hence to reduce the uncertainties during their flight testing.

  14. PLSS 2.5 Fan Design and Development

    Science.gov (United States)

    Converse, David; Carra, Michael; Quinn, Gregory; Chullen, Cinda

    2015-01-01

    NASA is building a high fidelity prototype of an advanced portable life support system (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge in order to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, is driven by a centrifugal fan developed using specifications from over five years ago. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement have been identified with the existing fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0. It uses the same basic non-metallic can around the motor, but with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 loop. This allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds. Development of the fan also considered a shrouded impeller design that allows larger clearances for greater oxygen safety and better performance.

  15. Development of a Fan for Future Space Suit Applications

    Science.gov (United States)

    Paul. Heather L.; Converse, David; Dionne, Steven; Moser, Jeff

    2010-01-01

    NASA's next generation space suit system will place new demands on the fan used to circulate breathing gas through the ventilation loop of the portable life support system. Long duration missions with frequent extravehicular activities (EVAs), the requirement for significant increases in reliability and durability, and a mission profile that imposes strict limits on weight, volume and power create the basis for a set of requirements that demand more performance than is available from existing fan designs. This paper describes the development of a new fan to meet these needs. A centrifugal fan was designed with a normal operating speed of approximately 39,400 rpm to meet the ventilation flow requirements while also meeting the aggressive minimal packaging, weight and power requirements. The prototype fan also operates at 56,000 rpm to satisfy a second operating condition associated with a single fan providing ventilation flow to two spacesuits connected in series. This fan incorporates a novel nonmetallic "can" to keep the oxygen flow separate from the motor electronics, thus eliminating ignition potential. The nonmetallic can enables a small package size and low power consumption. To keep cost and schedule within project bounds a commercial motor controller was used. The fan design has been detailed and implemented using materials and approaches selected to address anticipated mission needs. Test data is presented to show how this fan performs relative to anticipated ventilation requirements for the EVA portable life support system. Additionally, data is presented to show tolerance to anticipated environmental factors such as acoustics, shock, and vibration. Recommendations for forward work to progress the technology readiness level and prepare the fan for the next EVA space suit system are also discussed.

  16. Strengthening of bridges by post-tensioning using monostrands in substituted cable ducts

    Science.gov (United States)

    Klusáček, Ladislav; Svoboda, Adam

    2017-09-01

    Post-tensioning is suitable, reliable and durable method of strengthening existing engineering structures, especially bridges. The high efficiency of post-tensioning can be seen in many applications throughout the world. In this paper the method is extended by a structural system of substituted cable ducts, which allows for significantly widening application of prestressing so it’s convenient mostly for application on beam bridges or slab bridges (built in years 1920 - 1960). The method of substituted cable ducts is based on theoretical knowledge and technical procedures, which were made possible through the development in prestressing systems, particularly the development of prestressing tendons (monostrands) and encased anchorages, as well as progress in drilling technology. This technique is highly recommended due to minimization of interventions into the constructions, unseen method of cable arrangement and hence the absence of impact on appearance, which is appreciated not only in case of valuable historical structures but also in general. It is possible to summarise that posttensioning by monostrands in substituted cable ducts is a highly effective method of strengthening existing bridges in order to increase their load capacities in terms of current traffic load and to extend their service life.

  17. Aerodynamic modelling and optimization of axial fans

    Energy Technology Data Exchange (ETDEWEB)

    Noertoft Soerensen, Dan

    1998-01-01

    A numerically efficient mathematical model for the aerodynamics of low speed axial fans of the arbitrary vortex flow type has been developed. The model is based on a blade-element principle, whereby the rotor is divided into a number of annular stream tubes. For each of these stream tubes relations for velocity, pressure and radial position are derived from the conservation laws for mass, tangential momentum and energy. The equations are solved using the Newton-Raphson methods, and solutions converged to machine accuracy are found at small computing costs. The model has been validated against published measurements on various fan configurations, comprising two rotor-only fan stages, a counter-rotating fan unit and a stator-rotor stator stage. Comparisons of local and integrated properties show that the computed results agree well with the measurements. Optimizations have been performed to maximize the mean value of fan efficiency in a design interval of flow rates, thus designing a fan which operates well over a range of different flow conditions. The optimization scheme was used to investigate the dependence of maximum efficiency on 1: the number of blades, 2: the width of the design interval and 3: the hub radius. The degree of freedom in the choice of design variable and constraints, combined with the design interval concept, provides a valuable design-tool for axial fans. To further investigate the use of design optimization, a model for the vortex shedding noise from the trailing edge of the blades has been incorporated into the optimization scheme. The noise emission from the blades was minimized in a flow rate design point. Optimizations were performed to investigate the dependence of the noise on 1: the number of blades, 2: a constraint imposed on efficiency and 3: the hub radius. The investigations showed, that a significant reduction of noise could be achieved, at the expense of a small reduction in fan efficiency. (EG) 66 refs.

  18. 30 CFR 75.313 - Main mine fan stoppage with persons underground.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main mine fan stoppage with persons underground... mine fan stoppage with persons underground. (a) If a main mine fan stops while anyone is underground and the ventilating quantity provided by the fan is not maintained by a back-up fan system— (1...

  19. 30 CFR 77.212 - Draw-off tunnel ventilation fans; installation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Draw-off tunnel ventilation fans; installation... UNDERGROUND COAL MINES Surface Installations § 77.212 Draw-off tunnel ventilation fans; installation. When fans are used to ventilate draw-off tunnels the fans shall be: (a) Installed on the surface; (b...

  20. High-Resolution Geologic Mapping of Martian Terraced Fan Deposits

    Science.gov (United States)

    Wolak, J. M.; Patterson, A. B.; Smith, S. D.; Robbins, N. N.

    2018-06-01

    This abstract documents our initial progress (year 1) mapping terraced fan features on Mars. Our objective is to investigate the role of fluids during fan formation and produce the first high-resolution geologic map (1:18k) of a terraced fan.

  1. Aerodynamic Modelling and Optimization of Axial Fans

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft

    A numerically efficient mathematical model for the aerodynamics oflow speed axial fans of the arbitrary vortex flow type has been developed.The model is based on a blade-element principle, whereby therotor is divided into a number of annular streamtubes.For each of these streamtubes relations......-Raphson method, andsolutions converged to machine accuracy are found at small computing costs.The model has been validated against published measurementson various fan configurations,comprising two rotor-only fan stages, a counter-rotatingfan unit and a stator-rotor-stator stage.Comparisons of local...... and integrated propertiesshow that the computed results agree well with the measurements.Integrating a rotor-only version of the aerodynamic modelwith an algorithm for numerical designoptimization, enables the finding of an optimum fan rotor.The angular velocity of the rotor, the hub radius and the spanwise...

  2. The Lower Cretaceous Way Group of northern Chile: An alluvial fan-fan delta complex

    Science.gov (United States)

    Flint, S.; Clemmey, H.; Turner, P.

    1986-01-01

    Alluvial fan sediments of the Lower Cretaceous Coloso Basin in northern Chile were deposited in a half-graben and derived from andesitic volcanics of a former island arc. Transport directions were towards the east, away from the present-day Peru-Chile trench. Grain flow, density modified grain flow and sheetflow processes were responsible for most of the sediment deposition with cohesive debris flows playing only a minor part. An early phase of conglomerate deposition (Coloso Formation) into a restricted basin records the transition from proximal fan facies with abundant grain flows and remobilized screes to mid-fan facies dominated by sheetflows. Stratiform copper mineralization near the top of the lower conglomerates is related to the unroofing of the Jurassic island arc. This mineralization comprises copper sulphide-cemented sands and gravels and formed by the reaction of mineralized detritus with diagenetic and hydrothermal solutions. A later phase of deposition (Lombriz Formation) includes sandstones, siltstones and conglomerates with a source area different from the Coloso Formation. This change in source may be related to strike-slip tectonics as the basin extended. The Lombriz conglomerates pass distally (eastwards) into red sandstones and purple siltstones with thin limestones deposited under marine conditions. This sequence is interpreted as a major fan delta complex. It passes conformably into marine carbonates of the Tableado Formation signifying the complete drowning of the basin in lower Cretaceous times.

  3. New concept of the buildup factor in bent ducts

    International Nuclear Information System (INIS)

    Faik Ouahab, Z.; Jehouani, A.; Groetz, J.-E.

    2011-01-01

    A major problem confronting the radiation shielding designer is the accurate determination of neutron streaming through various penetrations in walls, ducts and mazes. The previous studies on neutron transmission were performed through empty ducts. The aim of this work is to evaluate the neutron transmission probability through a filled bent duct and the proposition of a new concept of the buildup factor for neutrons in multilegged ducts. An angular biaising technique is used in the Monte Carlo simulations to accelerate the calculation convergence. Results are first compared with those obtained by the MCNPX code. For an empty bent duct, the neutron transmission is only due to the neutron reflection on the duct wall. For a filled duct, the major contribution is due to the scattering on the atoms filling the duct.

  4. Generation After Next Propulsor Research: Robust Design for Embedded Engine Systems

    Science.gov (United States)

    Arend, David J.; Tillman, Gregory; O'Brien, Walter F.

    2012-01-01

    The National Aeronautics and Space Administration, United Technologies Research Center and Virginia Polytechnic and State University have contracted to pursue multi-disciplinary research into boundary layer ingesting (BLI) propulsors for generation after next environmentally responsible subsonic fixed wing aircraft. This Robust Design for Embedded Engine Systems project first conducted a high-level vehicle system study based on a large commercial transport class hybrid wing body aircraft, which determined that a 3 to 5 percent reduction in fuel burn could be achieved over a 7,500 nanometer mission. Both pylon-mounted baseline and BLI propulsion systems were based on a low-pressure-ratio fan (1.35) in an ultra-high-bypass ratio engine (16), consistent with the next generation of advanced commercial turbofans. An optimized, coupled BLI inlet and fan system was subsequently designed to achieve performance targets identified in the system study. The resulting system possesses an inlet with total pressure losses less than 0.5%, and a fan stage with an efficiency debit of less than 1.5 percent relative to the pylon-mounted, clean-inflow baseline. The subject research project has identified tools and methodologies necessary for the design of next-generation, highly-airframe-integrated propulsion systems. These tools will be validated in future large-scale testing of the BLI inlet / fan system in NASA's 8 foot x 6 foot transonic wind tunnel. In addition, fan unsteady response to screen-generated total pressure distortion is being characterized experimentally in a JT15D engine test rig. These data will document engine sensitivities to distortion magnitude and spatial distribution, providing early insight into key physical processes that will control BLI propulsor design.

  5. Molecular Mechanisms of Bile Duct Development

    OpenAIRE

    Zong, Yiwei; Stanger, Ben Z.

    2010-01-01

    The mammalian biliary system, consisting of the intrahepatic and extrahepatic bile ducts, is responsible for transporting bile from the liver to the intestine. Bile duct dysfunction, as is seen in some congenital biliary diseases such as Alagille syndrome and biliary atresia, can lead to the accumulation of bile in the liver, preventing the excretion of detoxification products and ultimately leading to liver damage. Bile duct formation requires coordinated cell-cell interactions, resulting in...

  6. Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers

    Directory of Open Access Journals (Sweden)

    Tianyong Jiang

    2017-09-01

    Full Text Available With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors’ previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD. To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA developed to utilize one Lead Zirconate Titanate (PZT transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon

  7. Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers.

    Science.gov (United States)

    Jiang, Tianyong; Zheng, Junbo; Huo, Linsheng; Song, Gangbing

    2017-09-29

    With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors' previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD). To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA) developed to utilize one Lead Zirconate Titanate (PZT) transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon duct.

  8. Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-07

    "9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

  9. Unilateral Duplication Of Parotid Duct. A Rare Anatomical Variation

    Directory of Open Access Journals (Sweden)

    Humberto Ferreira Arquez

    2017-11-01

    Full Text Available Background: The paired parotid glands are the largest of the major salivary glands and produces mainly serous secretions. The secretion of this gland reaches the oral cavity through single parotid duct (Stensen’s duct. The parotid duct begins at the anterior border of the gland, crosses the masseter muscle, and then pierces the buccinator muscle to reach the mucosa lining the mouth at the level of the cheek. The purpose of this study is determine the morphologic features of the parotid duct and describe an anatomical variation until now unreported. Methods and Findings: A total of 17 cadavers were used for this study in the Morphology Laboratory at the University of Pamplona. In a cadaver were findings: The main parotid duct originated two conducts: Left superior parotid duct and Left inferior parotid duct, is observed the criss-cross of the ducts, and then perforated the buccinator muscle and entered the oral cavity at a double parotid papilla containing a double opening, separated from each other in 0,98 mm. In the remaining  33 parotid regions (97.06% the parotid duct is conformed to the classical descriptions given in anatomical textbooks. Conclusions: The parotid duct anatomy is important for duct endoscopy, lithotripsy, sialography and trans-ductal facial nerve stimulation in the early stage of facial palsy in some cases. The anatomical variations also has clinical importance for parotid gland surgery and facial cosmetic surgery. To keep in mind the parotid duct variation will reduce iatrogenic injury risks and improve diagnosis of parotid duct injury.

  10. The Right to Be a Fan

    Science.gov (United States)

    Gutierrez, Peter

    2011-01-01

    Reading experts have consistently cited the importance of independent reading, reading for pleasure, and fostering "a love of reading." Unfortunately, fanning the fire of fan readership is not so easy in the service of our clear-cut and standards-aligned curricula, except perhaps in small, carefully channeled doses. Moreover, the impetus for such…

  11. The morphology, processes, and evolution of Monterey Fan: a revisit

    Science.gov (United States)

    Gardner, James V.; Bohannon, Robert G.; Field, Michael E.; Masson, Douglas G.

    2010-01-01

    Long-range (GLORIA) and mid-range (TOBI) sidescan imagery and seismic-reflection profiles have revealed the surface morphology and architecture of the complete Monterey Fan. The fan has not developed a classic wedge shape because it has been blocked for much of its history by Morro Fracture Zone. The barrier has caused the fan to develop an upper-fan and lower-fan sequence that are distinctly different from one another. The upper-fan sequence is characterized by Monterey and Ascension Channels and associated Monterey Channel-levee system. The lower-fan sequence is characterized by depositional lobes of the Ascension, Monterey, and Sur-Parkington-Lucia systems, with the Monterey depositional lobe being the youngest. Presently, the Monterey depositional lobe is being downcut because the system has reached a new, lower base level in the Murray Fracture Zone. A five-step evolution of Monterey Fan is presented, starting with initial fan deposition in the Late Miocene, about 5.5 Ma. This first stage was one of filling bathymetric lows in the oceanic basement in what was to become the upper-fan segment. The second stage involved filling the bathymetric low on the north side of Morro Fracture Zone, and probably not much sediment was transported beyond the fracture zone. The third stage witnessed sediment being transported around both ends of Morro Fracture Zone and initial sedimentation on the lower-fan segment. During the fourth stage Ascension Channel was diverted into Monterey Channel, thereby cutting off sedimentation to the Ascension depositional lobe.

  12. Thoracic duct lymphography by subcutaneous contrast agent ...

    African Journals Online (AJOL)

    A second lymphography revealed a collateral thoracic duct that was not detected during the first lymphography. The collateral duct was ligated and chylothorax was resolved after the second surgery. The lymphography applied in this study was minimally-invasive and easily provided images of the thoracic duct in a dog with ...

  13. Life, death and revival of debris-flow fans on Earth and Mars : fan dynamics and climatic inferences

    NARCIS (Netherlands)

    de Haas, T.|info:eu-repo/dai/nl/374023190

    2016-01-01

    Alluvial fans are ubiquitous landforms in high-relief regions on Earth and Mars. They have a semi-conical shape and are located at the transition between highlands and adjacent basins. Alluvial fans can form by a range of processes including debris flows, which are water-laden masses of soil and

  14. Fan-shaped antennas: Realization of wideband characteristics and generation of stop bands

    Science.gov (United States)

    Nakano, H.; Morishita, K.; Iitsuka, Y.; Mimaki, H.; Yoshida, T.; Yamauchi, J.

    2008-08-01

    This paper presents four fan-shaped antennas: U.S.-FAN, CROSS-FAN, CROSS-FAN-W, and CROSS-FAN-S. Each of these antennas stands upright above a ground plane, and has edges expressed by an exponential function and a circle function. The four antennas are investigated using frequencies from 1.5 GHz to 11 GHz. The CROSS-FAN is found to have a lower VSWR over a wide frequency band compared to the U.S.-FAN. The CROSS-FAN-W and CROSS-FAN-S are modified versions of the CROSS-FAN, each designed to have a stop band (a high VSWR frequency range) for interference cancellation. The stop band for the CROSS-FAN-W is controlled by a wire (total length 4Lwire) that connects the fan-shaped elements. The center frequency of the stop band fstop is close to the frequency corresponding to a wire segment length Lwire of half the wavelength. It is also found that the stop band in the CROSS-FAN-S can be controlled by four slots, one cut into each of the fan-shaped elements. The center frequency of the stop band fstop is close to the frequency corresponding to a slot length Lslot of one-quarter of the wavelength. Experimental work is performed to confirm the theoretical results, using the CROSS-FAN-S.

  15. Low frequency noise case study : identification and mitigation of a severe infrasonic tone from a mine shaft ventilation fan

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, R.D. [HGC Engineering, Mississauga, ON (Canada)

    2007-07-01

    This paper presented a solution for a severe low frequency infrasound problem experienced at a home near a large mine shaft ventilation fan in Dallas, West Virginia. Strong low frequency acoustic pulsations were detected as far as 200 metres from the fan. HGC Engineering was retained by the coal mine company to investigate the source of the problem and to find solutions. Controlling low frequency sound is a challenge because the wavelengths of sound are long at low frequencies. The relatively high level of acoustic energy of a low frequency sound or infrasound that is loud enough to be heard also presents a problem for noise control. In order to be effective, low frequency noise control measures must usually be large, bulky and expensive. In this study, HGC Engineering readily identified acoustic pulsations in the order of 75 dB at 15 Hz outside the residences. At 15 Hz, the infrasound was not audible at the residence, but was causing rattling of lightweight furnishings inside the home. The measured sound pressure level at 15 Hz was approximately 10 dB greater than the onset of risk for rattling and perceptible vibration. The vibration was also perceptible on the walls and windows of the dwellings. The vibration of the dwelling structure had a high measured coherence with the air-borne pulsations at 15 Hz, suggesting that the vibration was induced by the air-borne infrasonic pulsations. HGC Engineering determined that 15 Hz corresponded to the rotational speed of the fan. A reduction of 15 dB at 15 Hz was targeted, in order to reduce the perceptibility and risk of rattling at the residence. A tuned acoustic plenum was considered to be a viable method to silence the fan. In order to investigate the effectiveness of this approach, HGC Engineering conducted a preliminary analytical design and parametric study of an acoustic plenum tuned to 15 Hz. An analytical model was developed to determine the acoustic behaviour of the plenum. In addition, a numerical boundary

  16. Sherlock (Holmes in Japanese (fan works [symposium

    Directory of Open Access Journals (Sweden)

    Lori Morimoto

    2017-03-01

    Full Text Available I explore the history of Japanese writing centered on Sherlock Holmes as a means of interrogating the 2014 BBC Sherlock pastiche John and Sherlock Casebook 1: Jon, zenchi renmei e iku (The stark naked league, written by Japanese Sherlockian Kitahara Naohiko for mainstream publication by the publishing house Hayakawa shobō. I argue that exploration of the Japanese (fan cultural contexts of Kitahara's book begins to reveal the limits of the Anglo-American-centered framework through which fan studies scholars explore fan/producer relationships.

  17. weiqiang fan

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Genetics. WEIQIANG FAN. Articles written in Journal of Genetics. Volume 96 Issue 6 December 2017 pp 867-872 RESEARCH ARTICLE. A genetic variant in COL11A1 is functionally associated with lumbar disc herniation in Chinese population · WENJUN LIU GUISEN SUN LONGSHENG GUO ...

  18. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    Science.gov (United States)

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  19. Review of noise reduction methods for centrifugal fans

    Science.gov (United States)

    Neise, W.

    1981-11-01

    Several methods for the reduction of centrifugal fan noise are presented, the most of which are aimed at a lower blade passage frequency level. The methods are grouped into five categories: casing modifications to increase the distance between impeller and cutoff, the introduction of a phase shift of the source pressure fluctuations, impeller modifications, radial clearance between impeller eye and inlet nozzle, and acoustical measures. Resonators mounted at the cutoff of centrifugal fans appear to be a highly efficient and simple means of reducing the blade passage tone, and the method can be used for new fan construction and existing installations without affecting the aerodynamic performance of the fan.

  20. The performance of a centrifugal fan with enlarged impeller

    International Nuclear Information System (INIS)

    Li Chunxi; Song Lingwang; Jia Yakui

    2011-01-01

    Highlights: → The influence of impeller enlargement is evaluated numerically and experimentally. → Variation equations of the operation points for enlarged impellers are derived. → Impeller enlargement leads to louder fan noise due to reduced impeller-volute gap. - Abstract: The influence of enlarged impeller in unchanged volute on G4-73 type centrifugal fan performance is investigated in this paper. Comparisons are conducted between the fan with original impeller and two larger impellers with the increments in impeller outlet diameter of 5% and 10% respectively in the numerical and experimental investigations. The internal characteristics are obtained by the numerical simulation, which indicate there is more volute loss in the fan with larger impeller. Experiment results show that the flow rate, total pressure rise, shaft power and sound pressure level have increased, while the efficiency have decreased when the fan operates with larger impeller. Variation equations on the performance of the operation points for the fan with enlarged impellers are suggested. Comparisons between experiment results and the trimming laws show that the trimming laws for usual situation can predict the performance of the enlarged fan impeller with less error for higher flow rate, although the situation of application is not in agreement. The noise frequency analysis shows that higher noise level with the larger impeller fan is caused by the reduced impeller-volute gap.

  1. The performance of a centrifugal fan with enlarged impeller

    Energy Technology Data Exchange (ETDEWEB)

    Li Chunxi, E-mail: leechunxi@163.com [School of Energy and Power Engineering, North China Electric Power University, 071003 Baoding, Hebei (China); Song Lingwang [School of Energy and Power Engineering, North China Electric Power University, 071003 Baoding, Hebei (China); Jia Yakui [Hebei Electric Power Design and Research Institute, 050031 Shijiazhuang, Hebei (China)

    2011-08-15

    Highlights: {yields} The influence of impeller enlargement is evaluated numerically and experimentally. {yields} Variation equations of the operation points for enlarged impellers are derived. {yields} Impeller enlargement leads to louder fan noise due to reduced impeller-volute gap. - Abstract: The influence of enlarged impeller in unchanged volute on G4-73 type centrifugal fan performance is investigated in this paper. Comparisons are conducted between the fan with original impeller and two larger impellers with the increments in impeller outlet diameter of 5% and 10% respectively in the numerical and experimental investigations. The internal characteristics are obtained by the numerical simulation, which indicate there is more volute loss in the fan with larger impeller. Experiment results show that the flow rate, total pressure rise, shaft power and sound pressure level have increased, while the efficiency have decreased when the fan operates with larger impeller. Variation equations on the performance of the operation points for the fan with enlarged impellers are suggested. Comparisons between experiment results and the trimming laws show that the trimming laws for usual situation can predict the performance of the enlarged fan impeller with less error for higher flow rate, although the situation of application is not in agreement. The noise frequency analysis shows that higher noise level with the larger impeller fan is caused by the reduced impeller-volute gap.

  2. Self-retaining small-looped catheter for narrow bile ducts in high common bile duct obstruction

    International Nuclear Information System (INIS)

    Guenther, R.W.; Daehnert, W.

    1985-01-01

    A new self-retaining catheter was devised for percutaneous drainage of small bile ducts. The device allows safe external drainage without the risk of catheter dislocation even in high bile duct obstruction. The catheter is also suitable for percutaneous nephrostomy in non-dilated pyelocaliceal system. (orig.)

  3. A history of RPGs: Made by fans; played by fans

    Directory of Open Access Journals (Sweden)

    Paul Mason

    2012-09-01

    Full Text Available I explore some aspects of the early history of tabletop role-playing games (RPGs that are perhaps not well known among media scholars, and which offer an alternative take on the idea of fan activity.

  4. Single photon emission computed tomography by using fan beam collimator

    International Nuclear Information System (INIS)

    Akiyama, Yoshihisa

    1992-01-01

    A multislice fan beam collimator which has parallel collimation along the cephalic-caudul axis of a patient and converging collimation within planes that are perpendicular to that axis was designed for a SPECT system with a rotating scintillation camera, and it was constructed by the lead casting method which was developed in recent years. A reconstruction algorithm for fan beam SPECT was formed originally by combining the reconstruction algorithm of the parallel beam SPECT with that of the fan beam X-ray CT. The algorithm for fan beam SPECT was confirmed by means of computer simulation and a head phantom filled with diluted radionuclide. Not only 99m Tc but also 123 I was used as a radionuclide. A SPECT image with the fan beam collimator was compared with that of a parallel hole, low energy, high resolution collimator which was routinely used for clinical and research SPECT studies. Both system resolution and sensitivity of the fan beam collimator were ∼20% better than those of the parallel hole collimator. Comparing SPECT images obtained from fan beam collimator with those of parallel hole collimator, the SPECT images using fan beam collimator had far better resolution. A fan beam collimator is a useful implement for the SPECT study. (author)

  5. Performance/Noise Optimization of Centrifugal Fan Using Response Surface Method

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Donghui; Cheong, Cheolung [Pusan Nat’l Univ., Busan (Korea, Republic of); Heo Seung [Korea Aerospace Industries, Sacheon (Korea, Republic of); Kim, Tae-Hoon; Jung, Jiwon [LG Electronics, Seoul (Korea, Republic of)

    2017-03-15

    In this study, centrifugal fan blades used to circulate cold air inside a household refrigerator were optimized to achieve high performance and low noise by using the response surface method, which is frequently employed as an optimization algorithm when multiple independent variables affect one dependent variable. The inlet and outlet blade angles, and the inner radius, were selected as the independent variables. First, the fan blades were optimized to achieve the maximum volume flow rate. Based on this result, a prototype fan blade was manufactured using a 3-D printer. The measured P-Q curves confirmed the increased volume flow rate of the proposed fan. Then, the rotation speed of the new fan was decreased to match the P-Q curve of the existing fan. It was found that a noise reduction of 1.7 dBA could be achieved using the new fan at the same volume flow rate.

  6. Performance/Noise Optimization of Centrifugal Fan Using Response Surface Method

    International Nuclear Information System (INIS)

    Shin, Donghui; Cheong, Cheolung; Heo Seung; Kim, Tae-Hoon; Jung, Jiwon

    2017-01-01

    In this study, centrifugal fan blades used to circulate cold air inside a household refrigerator were optimized to achieve high performance and low noise by using the response surface method, which is frequently employed as an optimization algorithm when multiple independent variables affect one dependent variable. The inlet and outlet blade angles, and the inner radius, were selected as the independent variables. First, the fan blades were optimized to achieve the maximum volume flow rate. Based on this result, a prototype fan blade was manufactured using a 3-D printer. The measured P-Q curves confirmed the increased volume flow rate of the proposed fan. Then, the rotation speed of the new fan was decreased to match the P-Q curve of the existing fan. It was found that a noise reduction of 1.7 dBA could be achieved using the new fan at the same volume flow rate.

  7. Fan action and political participation on "The Colbert Report"

    Directory of Open Access Journals (Sweden)

    Marcus Schulzke

    2012-06-01

    Full Text Available The Colbert Report merges the increasingly popular political satire genre with fan activism. The result is that the fan community helps to construct Colbert's malleable character and demonstrates symbolic power through its willingness to act. The fans are usually a nonpartisan force, acting to produce entertainment rather than substantive political change. However, this can be politically meaningful, as the fans' projects promote collective action, parallel political activities like voting and protesting, and encourage critical thinking about political information.

  8. The Conceptual Design of High Pressure Reversible Axial Tunnel Ventilation Fans

    Directory of Open Access Journals (Sweden)

    A. G. Sheard

    2012-01-01

    Full Text Available Tunnel ventilation fans, classically, must have the ability to both supply and extract air from a tunnel system, with the operator's choice dependent on the tunnel ventilation system's operating mode most appropriate at any given point in time. Consequently, tunnel ventilation fans must incorporate a reversible aerodynamic design which limits the maximum fan pressure rise. This paper presents three high pressure reversible fan concepts. These comprise a two-stage counter rotating fan, a single-stage high speed fan, and a two-stage fan with a single motor and impeller on each end of the motor shaft. The authors consider the relative merits of each concept. The third concept offers the most compact fan, transform, silencer, and damper package size. The authors discuss the mechanical design challenges that occur with a two-stage fan with a single motor and impeller on each end of the motor shaft. They present and consider a selected motor bearing arrangement and casing design for maintainability. Finally, the authors present both prototype fan and full-scale package aerodynamic and acoustic performance, before discussing the challenges presented by high temperature certification in accordance with the requirements of EN 12101-3: 2012.

  9. Persistent Mullerian Duct Syndrome with Transverse Testicular ...

    African Journals Online (AJOL)

    Eastham JA, McEvoy K, Sullivan R, Chandrasoma P. A case of simultaneous bilateral nonseminomatous testicular tumors in persistent müllerian duct syndrome. J Urol 1992;148:407-8. 8. Shinmura Y, Yokoi T, Tsutsui Y. A case of clear cell adenocarcinoma of the müllerian duct in persistent müllerian duct syndrome: The first ...

  10. Simulating Effects of High Angle of Attack on Turbofan Engine Performance

    Science.gov (United States)

    Liu, Yuan; Claus, Russell W.; Litt, Jonathan S.; Guo, Ten-Huei

    2013-01-01

    A method of investigating the effects of high angle of attack (AOA) flight on turbofan engine performance is presented. The methodology involves combining a suite of diverse simulation tools. Three-dimensional, steady-state computational fluid dynamics (CFD) software is used to model the change in performance of a commercial aircraft-type inlet and fan geometry due to various levels of AOA. Parallel compressor theory is then applied to assimilate the CFD data with a zero-dimensional, nonlinear, dynamic turbofan engine model. The combined model shows that high AOA operation degrades fan performance and, thus, negatively impacts compressor stability margins and engine thrust. In addition, the engine response to high AOA conditions is shown to be highly dependent upon the type of control system employed.

  11. Aeromechanics Analysis of a Boundary Layer Ingesting Fan

    Science.gov (United States)

    Bakhle, Milind A.; Reddy, T. S. R.; Herrick, Gregory P.; Shabbir, Aamir; Florea, Razvan V.

    2013-01-01

    Boundary layer ingesting propulsion systems have the potential to significantly reduce fuel burn but these systems must overcome the challe nges related to aeromechanics-fan flutter stability and forced response dynamic stresses. High-fidelity computational analysis of the fan a eromechanics is integral to the ongoing effort to design a boundary layer ingesting inlet and fan for fabrication and wind-tunnel test. A t hree-dimensional, time-accurate, Reynolds-averaged Navier Stokes computational fluid dynamics code is used to study aerothermodynamic and a eromechanical behavior of the fan in response to both clean and distorted inflows. The computational aeromechanics analyses performed in th is study show an intermediate design iteration of the fan to be flutter-free at the design conditions analyzed with both clean and distorte d in-flows. Dynamic stresses from forced response have been calculated for the design rotational speed. Additional work is ongoing to expan d the analyses to off-design conditions, and for on-resonance conditions.

  12. Development of GE90 engine with largest thrust. GE90 engine no kaihatsu jokyo

    Energy Technology Data Exchange (ETDEWEB)

    Aono, H [Ishikawajima-Harima Heavy Industries, Co. Ltd., Tokyo (Japan)

    1994-05-01

    The present paper explained the turbofan engine GE90 which is being developed by General Electric Co., USA. That engine is to meet the thrust (takeoff thrust) of 300 to 530kN as required for the new-generation wide-fuselage civil transport plane which is being designed for its planned operation in the 1990's. In April, 1991, the world's strongest thrust of 480kN was achieved with engine elements also confirmed through element test. Thereafter, the engine underwent a flying test on board of Boeing 747 to materialize the planned operation in 1995. Made to be 9 in by-pass ratio and about 40 in overall pressure ratio, the GE90 was given the concept that advantage could be secured in both propulsive efficiency and thermal efficiency. That concept could be materialized by the development of composite fan blade technology and energy-efficient technology which were both demonstrated with an unducted fan. In spite of its pressure ratio of 22, the GE90's high pressure compressor demonstrates its polytropic efficiency which is equal to that of the low pressure ratio compressor. 3 refs., 19 figs., 1 tab.

  13. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States)

    2016-09-01

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  14. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States)

    2016-09-08

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  15. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, Malachi; Ayyagari, Raj R. [Yale School of Medicine, Yale New Haven Hospital, New Haven, CT (United States); Division of Interventional Radiology, Department of Radiology, 789 Howard Avenue, P.O. Box 208042, New Haven, CT (United States)

    2015-06-15

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  16. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    International Nuclear Information System (INIS)

    Courtney, Malachi; Ayyagari, Raj R.

    2015-01-01

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  17. Fan-beam intensity modulated proton therapy.

    Science.gov (United States)

    Hill, Patrick; Westerly, David; Mackie, Thomas

    2013-11-01

    This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques. A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0-255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets. Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal

  18. Parotid Duct Repair with Intubation Tube: Technical Note

    Science.gov (United States)

    Öztürk, Muhammed Beşir; Barutca, Seda Asrufoğlu; Keskin, Elif Seda; Atik, Bekir

    2017-01-01

    The parotid duct can be damaged in traumatic injuries and surgical interventions. Early diagnosis and treatment of a duct injury is of great importance because complications such as sialocele and salivary gland fistula may develop if the duct is not surgically repaired. We think the cuff of an intubation tube is an ideal material in parotid duct repair, because of its technical characteristics, easiness of availability, and low-cost. In this paper, we described the use of the cuff cannula of an intubation tube for the diagnosis and treatment of parotid duct laceration, as a low-cost and easy to access material readily available in every operating room. PMID:28713751

  19. CFD validation by measurement of specialized ventilation equipments on duct tract

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2017-01-01

    Full Text Available This article describes measurement of HVAC distribution box on air duct track in Laboratory of Environmental Engineering (LEE. Firstly, the paper describes the LEE and then measurement apparatus with description of calculation methods. Then follows specification of sample with introduction to newly developed equipment for positioning of the anemometer. The evaluation of results of measurements with CFD comparison follows. The article is concluded with discussion over measured data with an outline for further research.

  20. Distributed Turboelectric Propulsion for Hybrid Wing Body Aircraft

    Science.gov (United States)

    Kim, Hyun Dae; Brown, Gerald V.; Felder, James L.

    2008-01-01

    Meeting future goals for aircraft and air traffic system performance will require new airframes with more highly integrated propulsion. Previous studies have evaluated hybrid wing body (HWB) configurations with various numbers of engines and with increasing degrees of propulsion-airframe integration. A recently published configuration with 12 small engines partially embedded in a HWB aircraft, reviewed herein, serves as the airframe baseline for the new concept aircraft that is the subject of this paper. To achieve high cruise efficiency, a high lift-to-drag ratio HWB was adopted as the baseline airframe along with boundary layer ingestion inlets and distributed thrust nozzles to fill in the wakes generated by the vehicle. The distributed powered-lift propulsion concept for the baseline vehicle used a simple, high-lift-capable internally blown flap or jet flap system with a number of small high bypass ratio turbofan engines in the airframe. In that concept, the engine flow path from the inlet to the nozzle is direct and does not involve complicated internal ducts through the airframe to redistribute the engine flow. In addition, partially embedded engines, distributed along the upper surface of the HWB airframe, provide noise reduction through airframe shielding and promote jet flow mixing with the ambient airflow. To improve performance and to reduce noise and environmental impact even further, a drastic change in the propulsion system is proposed in this paper. The new concept adopts the previous baseline cruise-efficient short take-off and landing (CESTOL) airframe but employs a number of superconducting motors to drive the distributed fans rather than using many small conventional engines. The power to drive these electric fans is generated by two remotely located gas-turbine-driven superconducting generators. This arrangement allows many small partially embedded fans while retaining the superior efficiency of large core engines, which are physically separated

  1. Dispersion properties of ducted whistlers, generated by lightning discharge

    Directory of Open Access Journals (Sweden)

    D. L. Pasmanik

    2005-06-01

    Full Text Available Whistler-mode wave propagation in magnetospheric ducts of enhanced cold plasma density is studied. The case of the arbitrary ratio of the duct radius to the whistler wavelength is considered, where the ray-tracing method is not applicable. The set of duct eigenmodes and their spatial structure are analysed and dependencies of eigenmode propagation properties on the duct characteristics are studied. Special attention is paid to the analysis of the group delay time of one-hop propagation of the whistler wave packet along the duct. We found that, in contrast to the case of a wide duct, the group delay time in a rather narrow duct decreases as the eigenmode number increases. The results obtained are suggested for an explanation of some types of multi-component whistler signals.

  2. CONSUMER BEHAVIOUR TOWARDS ELECTRIC FANS

    OpenAIRE

    Inderpreet Singh

    2017-01-01

    The study of consumer behaviour develops great interest for consumers, students, scientists, and marketers. As consumers, we need insights into our own consumption related decisions: what we buy, why we buy, and how we buy. The aim of the study is to cover entire research about consumer behaviour towards electric fans and different factors affecting their buying decision. A sample of 200 consumers of electric fans is taken. Questionnaire has been analysed with the help of pie diagram & bar ch...

  3. FACTORS INFLUENCING BRAND LOYALTY IN PROFESSIONAL SPORTS FANS

    OpenAIRE

    Yun-Tsan Lin; Chen-Hsien Lin

    2008-01-01

    Many researchers have provided comprehensive definitions for the term of brand loyalty and also examined the factors affecting brand loyalty with many empirical studies. But there is little research focusing on the brand loyalty of professional sports fans. The topic area about factors influencing brand loyalty in professional sports fans was identified because these fans bring significant financial benefits every year and stimulate economic growth in the United States. Although different con...

  4. Dynamic pressure as a measure of gas turbine engine (GTE) performance

    International Nuclear Information System (INIS)

    Rinaldi, G; Stiharu, I; Packirisamy, M; Nerguizian, V; Landry, R Jr; Raskin, J-P

    2010-01-01

    Utilizing in situ dynamic pressure measurement is a promising novel approach with applications for both control and condition monitoring of gas turbine-based propulsion systems. The dynamic pressure created by rotating components within the engine presents a unique opportunity for controlling the operation of the engine and for evaluating the condition of a specific component through interpretation of the dynamic pressure signal. Preliminary bench-top experiments are conducted with dc axial fans for measuring fan RPM, blade condition, surge and dynamic temperature variation. Also, a method, based on standing wave physics, is presented for measuring the dynamic temperature simultaneously with the dynamic pressure. These tests are implemented in order to demonstrate the versatility of dynamic pressure-based diagnostics for monitoring several different parameters, and two physical quantities, dynamic pressure and dynamic temperature, with a single sensor. In this work, the development of a dynamic pressure sensor based on micro-electro-mechanical system technology for in situ gas turbine engine condition monitoring is presented. The dynamic pressure sensor performance is evaluated on two different gas turbine engines, one having a fan and the other without

  5. Booster fans : some considerations for their usage in underground coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Gillies, S.; Slaughter, C. [Missouri Univ. of Science and Technology, Rolla, MO (United States); Calizaya, F. [Utah Univ., Salt Lake City, UT (United States); Wu, H.W. [Gillies Wu Mining Technology Pty Ltd., Brisbane, QLD (Australia)

    2010-07-01

    This paper reported on a study that investigated the conditions under which booster fans can be used safely and efficiently in underground coal mines. Booster fans are installed in series with a main surface fan and are used to boost the air pressure of the ventilation air passing through it. Several coal mining countries use booster fans, but in the United States, they are only used in metal/non-metal mines due to concerns of uncontrolled recirculation. This study investigated installations of booster fans in non-US underground coal mines where safe and efficient atmospheric conditions are achieved. The purpose was to collect reliable information on airway resistances and flow requirements typical in large US coal mines. The study showed that safe booster fan installations are found in both high and low gas conditions, and sometimes where workings are located at great depths. The interlocking systems within the booster fan can control the underground fans and avoid recirculation when surface fans are unexpectedly turned off. Another purpose of the study was to determine when booster fans become a more viable solution in coal mines due to increases in air requirements at higher production rates. It was concluded that a new fan selection algorithm to produce recirculation-free ventilation designs will be developed to enable US coal mine operators to develop ventilation designs to extract coal seams from depths greater than 1000 m. 17 refs., 1 fig.

  6. 30 CFR 57.22209 - Auxiliary fans (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Auxiliary fans (I-C mines). 57.22209 Section 57... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22209 Auxiliary fans (I-C mines). Electric auxiliary fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18...

  7. Solitary intrahepatic bile-duct cyst presenting with Jaundice

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Chun, Ki Sung; Ha, Hyun Kwon; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Jun Gi

    1989-01-01

    Caroli's disease is an uncommon condition, and characterized by congenital segmental saccular dilatation of intrahepatic bile ducts. A case of Caroli's disease, manifested by only a large communicating cystic dilatation of left intrahepatic bile duct and causing extrinsic pressure over the extrahepatic bile duct, is presented. The patient was 43-year-old housewife, hospitalized because of abdominal distension and severe jaundice. To relieve jaundice and alleviate surgical intervention, percutaneous drainage of the bile-duct cyst preceded surgery

  8. Stirling engine power control

    Science.gov (United States)

    Fraser, James P.

    1983-01-01

    A power control method and apparatus for a Stirling engine including a valved duct connected to the junction of the regenerator and the cooler and running to a bypass chamber connected between the heater and the cylinder. An oscillating zone of demarcation between the hot and cold portions of the working gas is established in the bypass chamber, and the engine pistons and cylinders can run cold.

  9. Study on afterburner of aircraft engine. Koku engine yo afterburner no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T [Ishikawajima-Harima Heavy Industries, Co. Ltd., Tokyo (Japan)

    1991-03-01

    This paper explains concepts of aircraft engine afterburner, and describes history of afterburner study, and describe the result of major research items. An afterburner is located down stream of a fan, compressor, burner, and turbine in a jet engine. Its basic principle is that fuel is injected into turbine exhaust and fan air flows from an fuel injector, ignited by a spark plug using oxygen remaining in the exhaust gas flow, burned and flame-held by a flame stabilizer. The combustion gas of high temperature (1,700 to 1,800 {degree}c) thus generated is jetted out from an exhaust nozzle to increase the thrust. The prototype afterburner is featured by adoption of a mixed type fuel injection system that provides wide stable combustion range, and flame stabilizer with a scoop aimed at improving the ignition performance and combustion efficiency. A confirmation test verified smooth ignition and wide air to fuel ratio for stabilized combustion. 4 refs., 16 figs.

  10. MRI ductography of contrast agent distribution and leakage in normal mouse mammary ducts and ducts with in situ cancer.

    Science.gov (United States)

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S

    2017-07-01

    High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (pcontrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Amateur mythographies: Fan fiction and the myth of myth

    Directory of Open Access Journals (Sweden)

    Ika Willis

    2016-03-01

    Full Text Available This paper draws on classical scholarship on myth in order to critically examine three ways in which scholars and fans have articulated a relationship between fan fiction and myth. These are (1 the notion of fan fiction as a form of folk culture, reclaiming popular story from corporate ownership; (2 the notion of myth as counterhegemonic, often feminist, discourse; (3 the notion of myth as a commons of story and a universal story world. I argue that the first notion depends on an implicit primitivizing of fan fiction and myth, which draws ultimately on the work of Gottfried von Herder in the 18th century and limits our ability to produce historically and politically nuanced understandings of fan fiction. The second notion, which is visible in the work of Henry Jenkins and Constance Penley, is more helpful because of its attention to the politics of narration. However, it is the third model of myth, as a universal story world, where we find the richest crossover between fan fiction's creative power and contemporary classical scholarship on myth, especially in relation to Sarah Iles Johnston's analysis of hyperserial narrative. I demonstrate this through some close readings of fan fiction from the Greek and Roman Mythology fandom on Archive of Our Own. I conclude the paper by extending Johnston's arguments to show that fan-fictional hyperseriality, specifically, can be seen as mythic because it intervenes not only in the narrative worlds of its source materials but also in the social world of its telling.

  12. The completion of the mathematical model by parameter identification for simulating a turbofan engine

    Directory of Open Access Journals (Sweden)

    Irina Carmen ANDREI

    2015-09-01

    Full Text Available The purpose of this paper is to set up a method to determine the missing engine design parameters (turbine inlet temperature T3T, airflow rate which significantly influence the jet engines thrust. The authors have introduced a new non-linear equation connecting the fan specific work with the temperature T3T, customized for turbofan. The method of chords, since it converges unconditionally, has been used for solving the non-linear equation of variable temperature T3T. An alternate method, based for the same relation between fan specific work and T3T, has been presented in purpose to determine airflow rate and fan pressure ratio. Two mixed flows turbofans have been considered as study cases. For case #1 it was determined a value comparable to the Turbomeca Larzac turbofan series 04-C6 and 04-C20 which power the AlphaJet machines (series A - Luftwaffe, series E - Dassault Dornier. For the F100-PW229 turbofan, as case #2, being given T3T, then have been determined the airflow rate, fan pressure ratio and fan specific work. After completing the mathematical model with the missing parameters, the performances of the engines at off-design regimes and the operational envelopes revealing i.e. the variations of thrust, specific thrust and fuel specific consumption with altitude and Mach number have been calculated.

  13. Synchronous and Cogged Fan Belt Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, Dylan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, Jesse [National Renewable Energy Lab. (NREL), Golden, CO (United States); Acosta, Jason [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    The GSA Regional GPG Team commissioned the National Renewable Energy Laboratory (NREL) to perform monitoring of cogged V-belts and synchronous belts on both a constant volume and a variable air volume fan at the Byron G. Rodgers Federal Building and U.S. Courthouse in Denver, Colorado. These motor/fan combinations were tested with their original, standard V-belts (appropriately tensioned by an operation and maintenance professional) to obtain a baseline for standard operation. They were then switched to the cogged V-belts, and finally to synchronous belts. The power consumption by the motor was normalized for both fan speed and air density changes. This was necessary to ensure that the power readings were not influenced by a change in rotational fan speed or by the power required to push denser air. Finally, energy savings and operation and maintenance savings were compiled into an economic life-cycle cost analysis of the different belt options.

  14. Case study of French and Spanish fan reception of Game of Thrones

    Directory of Open Access Journals (Sweden)

    Mélanie Bourdaa

    2015-06-01

    Full Text Available The reception of the American TV show Game of Thrones (2011– by French and Spanish fans and nonfans is addressed via a qualitative methodology, the goal of which is to understand how European viewers perceive themselves as fans and what it means for them to be fans. Analysis of characteristics of a specifically European reception helps us learn what fan studies tell us about fans and what fans really think about fandoms.

  15. Erosion and deposition on a debris-flow fan

    Science.gov (United States)

    Densmore, A. L.; Schuerch, P.; Rosser, N. J.; McArdell, B. W.

    2011-12-01

    The ability of a debris flow to entrain or deposit sediment controls the downstream evolution of flow volume, and ultimately dictates both the geomorphic impact of the flow and the potential hazard that it represents. Our understanding of the patterns of, and controls on, such flow volume changes remains extremely limited, however, partly due to a poor mechanistic grasp of the interactions between debris flows and their bed and banks. In addition, we lack a good understanding of the cumulative long-term effects of sequences of flows in a single catchment-fan system. Here we begin to address these issues by using repeated terrestrial laser scanning (TLS) to characterize the detailed surface change associated with the passage of multiple debris flows on the Illgraben fan, Switzerland. We calculate surface elevation change along a 300 m study reach, and from this derive the downfan rate of flow volume change, or lag rate; for comparison, we also derive the spatially-averaged lag rate over the entire ~2 km length of the fan. Lag rates are broadly comparable over both length scales, indicating that flow behavior does not vary significantly across the fan for most flows, but importantly we find that flow volume at the fan head is a poor predictor of volume at the fan toe. The sign and magnitude of bed elevation change scale with local flow depth; at flow depths 2 m. On the Illgraben fan, this depth corresponds to a basal shear stress of 3-4 kPa. Because flow depth is in part a function of channel cross-sectional topography, which varies strongly both within and between flows, this result indicates that erosion and deposition are likely to be highly dynamic. The dependence of flow volume change on both the channel topography and the flow history may thus complicate efforts to predict debris-flow inundation areas by simple flow routing. We then apply a 2d numerical model of debris-flow fan evolution to explore the key controls on debris-flow routing and topographic

  16. Active Piezoelectric Vibration Control of Subscale Composite Fan Blades

    Science.gov (United States)

    Duffy, Kirsten P.; Choi, Benjamin B.; Provenza, Andrew J.; Min, James B.; Kray, Nicholas

    2012-01-01

    As part of the Fundamental Aeronautics program, researchers at NASA Glenn Research Center (GRC) are investigating new technologies supporting the development of lighter, quieter, and more efficient fans for turbomachinery applications. High performance fan blades designed to achieve such goals will be subjected to higher levels of aerodynamic excitations which could lead to more serious and complex vibration problems. Piezoelectric materials have been proposed as a means of decreasing engine blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. To investigate this idea, spin testing was performed on two General Electric Aviation (GE) subscale composite fan blades in the NASA GRC Dynamic Spin Rig Facility. The first bending mode (1B) was targeted for vibration control. Because these subscale blades are very thin, the piezoelectric material was surface-mounted on the blades. Three thin piezoelectric patches were applied to each blade two actuator patches and one small sensor patch. These flexible macro-fiber-composite patches were placed in a location of high resonant strain for the 1B mode. The blades were tested up to 5000 rpm, with patches used as sensors, as excitation for the blade, and as part of open- and closed-loop vibration control. Results show that with a single actuator patch, active vibration control causes the damping ratio to increase from a baseline of 0.3% critical damping to about 1.0% damping at 0 RPM. As the rotor speed approaches 5000 RPM, the actively controlled blade damping ratio decreases to about 0.5% damping. This occurs primarily because of centrifugal blade stiffening, and can be observed by the decrease in the generalized electromechanical coupling with rotor speed.

  17. ß-adrenergic regulation of ion transport in pancreatic ducts: Patch-clamp study of isolated rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I

    1998-01-01

    BACKGROUND & AIMS: In the intact pancreas, bicarbonate secretion is thought to be controlled by a number of regulators, including adrenergic agonists. The aim of this study was to investigate the effects of adrenergic agonists on pancreatic ducts, which are the site of bicarbonate secretion....... METHODS: Small intralobular ducts were isolated from rat pancreas and studied in vitro by the whole-cell patch clamp technique. Cell membrane voltages and currents were indicators of cellular ion transport. In some ducts, intracellular Ca2+ activity was measured by fluorescence optical methods. RESULTS...

  18. Experimental and Numerical Investigation of a 60cm Diameter Bladeless Fan

    OpenAIRE

    mohammad jafari; Hossein Afshin; Bijan Farhanieh; Hamidreza bozorgasareh

    2016-01-01

    Bladeless fan is a novel type of fan with an unusual geometry and unique characteristics. This type of fan has been recently developed for domestic applications in sizes typically up to 30cm diameter. In the present study, a Bladeless fan with a diameter of 60cm was designed and constructed, in order to investigate feasibility of its usage in various industries with large dimensions. Firstly, flow field passed through this fan was studied by 3D modeling. Aerodynamic and aeroacoust...

  19. Pressure analysis in ventilation ducts at bituminization facility

    International Nuclear Information System (INIS)

    Kikuchi, Naoki; Iimura, Masato; Takahashi, Yuki; Omori, Eiichi; Yamanouchi, Takamichi

    1997-09-01

    Pressure analysis in cell ventilation ducts at bituminization facility where the fire and explosion accident occured was carried out. This report also describes the results of bench mark calculations for computer code EVENT84 which was used for the accident analysis. The bench mark calculations were performed by comparing the analytical results by EVENT84 code with the experimental data of safety demonstration tests of ventilation system which were carried out by JAERI. We confirmed the applicability of EVENT84 code with the conservative results. The pressure analysis in cell ventilation ducts at bituminization facility were performed by comparing the analytical results of duct pressure by EVENT84 code with the yield stress of destroyed ducts by explosion, in order to estimate the scale of explosion. As a result, we could not explain the damage of ducts quantitatively, but we found the local pressure peaks analytically in downstream ducts where the serious damages were observed. (author)

  20. Development of regularized expectation maximization algorithms for fan-beam SPECT data

    International Nuclear Information System (INIS)

    Kim, Soo Mee; Lee, Jae Sung; Lee, Dong Soo; Lee, Soo Jin; Kim, Kyeong Min

    2005-01-01

    SPECT using a fan-beam collimator improves spatial resolution and sensitivity. For the reconstruction from fan-beam projections, it is necessary to implement direct fan-beam reconstruction methods without transforming the data into the parallel geometry. In this study, various fan-beam reconstruction algorithms were implemented and their performances were compared. The projector for fan-beam SPECT was implemented using a ray-tracing method. The direct reconstruction algorithms implemented for fan-beam projection data were FBP (filtered backprojection), EM (expectation maximization), OS-EM (ordered subsets EM) and MAP-EM OSL (maximum a posteriori EM using the one-step late method) with membrane and thin-plate models as priors. For comparison, the fan-beam projection data were also rebinned into the parallel data using various interpolation methods, such as the nearest neighbor, bilinear and bicubic interpolations, and reconstructed using the conventional EM algorithm for parallel data. Noiseless and noisy projection data from the digital Hoffman brain and Shepp/Logan phantoms were reconstructed using the above algorithms. The reconstructed images were compared in terms of a percent error metric. For the fan-beam data with Poisson noise, the MAP-EM OSL algorithm with the thin-plate prior showed the best result in both percent error and stability. Bilinear interpolation was the most effective method for rebinning from the fan-beam to parallel geometry when the accuracy and computation load were considered. Direct fan-beam EM reconstructions were more accurate than the standard EM reconstructions obtained from rebinned parallel data. Direct fan-beam reconstruction algorithms were implemented, which provided significantly improved reconstructions

  1. Friction coefficient measurements of silencers on specialized duct tract

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2016-01-01

    Full Text Available This article describes test methods on air duct track in Laboratory of Environmental Engineering. It focuses on measurement of silencer parameter like is pressure loss coeffcient. Firstly, the paper describe the measurement apparatus with description of calculation method by standard ISO 7235 and energy equation. Then the paper presents three ways how to accomplish measurement because such way is not covered by procedure in standard. Then follows the evaluation of results of measurements on three types of silencer designed for HVAC applications. The article is concluded with discussion over measured data with outline for further research.

  2. Using Innovative Technologies for Manufacturing Rocket Engine Hardware

    Science.gov (United States)

    Betts, E. M.; Eddleman, D. E.; Reynolds, D. C.; Hardin, N. A.

    2011-01-01

    Many of the manufacturing techniques that are currently used for rocket engine component production are traditional methods that have been proven through years of experience and historical precedence. As the United States enters into the next space age where new launch vehicles are being designed and propulsion systems are being improved upon, it is sometimes necessary to adopt innovative techniques for manufacturing hardware. With a heavy emphasis on cost reduction and improvements in manufacturing time, rapid manufacturing techniques such as Direct Metal Laser Sintering (DMLS) are being adopted and evaluated for their use on NASA s Space Launch System (SLS) upper stage engine, J-2X, with hopes of employing this technology on a wide variety of future projects. DMLS has the potential to significantly reduce the processing time and cost of engine hardware, while achieving desirable material properties by using a layered powder metal manufacturing process in order to produce complex part geometries. Marshall Space Flight Center (MSFC) has recently hot-fire tested a J-2X gas generator (GG) discharge duct that was manufactured using DMLS. The duct was inspected and proof tested prior to the hot-fire test. Using a workhorse gas generator (WHGG) test fixture at MSFC's East Test Area, the duct was subjected to extreme J-2X hot gas environments during 7 tests for a total of 537 seconds of hot-fire time. The duct underwent extensive post-test evaluation and showed no signs of degradation. DMLS manufacturing has proven to be a viable option for manufacturing rocket engine hardware, and further development and use of this manufacturing method is recommended.

  3. Improved recovery from Gulf of Mexico reservoirs. Volume I (of 4): Task 1, conduct research on mud-rich submarine fans. Final report, February 14, 1995--October 13, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Kimbrell, W.C.; Bassiouni, Z.A.; Bourgoyne, A.T.

    1997-01-13

    The objective for this portion of the research involved conducting field studies and laboratory investigations to develop and refine models for mud-rich submarine fan architectures used by seismic analysis and reservoir engineers. These research aspects have been presented in two papers as follows: (1) Bouma, A.H., {open_quotes}Review of Fine-Grained Submarine Fans and Turbidite Systems{close_quotes}; (2) Kirkova, J.T. and Lorenzo, J.M., {open_quotes}Synthetic Seismic Modeling of Measured Submarine Fans Sections, Case Study of the Tanqua Complex, Karoo, South Africa{close_quotes} The {open_quotes}Review of Fine-Grained Submarine Fans and Turbidite Systems{close_quotes} by Arnold Bouma discusses research targeted toward stimulating an increase in oil and gas recovery by developing new and improved geological understanding. The {open_quotes}Synthetic Seismic Modeling of Measured Submarine Fan Sections, Case Study of the Tanqua Complex, Karoo, South Africa{close_quotes} by J.T. Kirkova and J.M. Lorenso discusses the limitations of verticle resolution and how this affects the interpretation and characterization of submarine fan complexes.

  4. The Female Vikings, a women's fan group in Denmark

    DEFF Research Database (Denmark)

    Mintert, Svenja-Maria; Pfister, Gertrud Ursula

    2014-01-01

    on the historical development of a Danish women-only fan group called 'The Female Vikings', which support a professional football club, Lyngby Boldklub (BK), in a city north of Copenhagen. The article explores the backgrounds and motivations of female fans, as well as their ways of staging femininity in a man...... of the female fans during the club's 'crisis' and their 'collective memories'....

  5. Fifty shades of exploitation: Fan labor and Fifty Shades of Grey

    Directory of Open Access Journals (Sweden)

    Bethan Jones

    2014-03-01

    Full Text Available This exploration of the debates that have taken place in fandom over the ethics of pulling fan fiction and publishing it as original work draws on the notion of the fannish gift economy, which postulates that gifts such as fan fiction and fan art have value in the fannish community because they are designed to create and cement its social structure. Tension exists between fans who subscribe to the notion of a fannish gift economy and those who exploit fandom by using it to sell their pulled-to-publish works. An examination of E. L. James's 2012 Fifty Shades trilogy (comprising the books Fifty Shades of Grey, Fifty Shades Darker, and Fifty Shades Freed, which began as Twilight fan fiction, in addition to Twilight fan art sold through sites such as Redbubble and Etsy, demonstrates a tension between the two modes of fan expression: sale of artworks appears to be an acceptable practice in fandom, but the commercial sale of fan fic, even when marketed as original fiction, is widely contested.

  6. Improving Fan System Performance: A Sourcebook for Industry

    Energy Technology Data Exchange (ETDEWEB)

    2003-04-01

    This is one of a series of sourcebooks on motor-driven equipment produced by the Industrial Technologies Program. It provides a reference for industrial fan systems users, outlining opportunities to improve fan system performance.

  7. High pressure axial flow fans for modern coal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Cyrus, Vaclav [AHT Energetika s.r.o., Praha (Czech Republic); Koci, Petr [ZVVZ Milevsko a.s. (Czech Republic)

    2008-07-01

    Brown coal fired power stations, located in Northern Bohemia, have mostly older boiler blocks with an output of 110 and 200 MWe. Flue gases are cleaned by the desulphurization plants installed between 1993 and 1997. Usually, each boiler block has two air fans and one to three flue gas fans. Flue gas fans operate in severe conditions; fan blades should be resistant to the flue gases containing sulphur and acid drops with the operating temperature at 170 C to 190 C. Additionally, flue gas also often contains ash particles. Currently, some boiler blocks are gradually being refurbished. New blocks with an electrical power output of 600 to 700 MWe are at the design stage. Submitted paper shows our design study of one stage axial flow fan for the new blocks. Results from the new aerodynamic research of the axial flow stages were used in the fan design. (orig.)

  8. Effect of temperature change at inlet of engine on the corrected performance of turbofan engine

    Energy Technology Data Exchange (ETDEWEB)

    Kozu, Masao; Yajima, Satoshi [Defence Agency, Tokyo, JapanIshikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1989-06-10

    Theoretical consideration on the effect of inlet temperature change of engine on the engine performance was conducted, and soundness of the result was appreciated by applying it to the experimental result of turbofan engine. As the theoretical consideration, premises of Buckingham's fundamental theorem was corrected by Reynolds Number and by the consideration on the effect of inlet temperature on gas constant and specific heat ratio. By using the result, correction factors were calculated from the experimental result of an actual turbo-fan engine. The correction factors were applied to the other engine test result and confirmed satisfactory soundness. 4 refs., 11 figs.

  9. Mean streamline analysis for performance prediction of cross-flow fans

    International Nuclear Information System (INIS)

    Kim, Jae Won; Oh, Hyoung Woo

    2004-01-01

    This paper presents the mean streamline analysis using the empirical loss correlations for performance prediction of cross-flow fans. Comparison of overall performance predictions with test data of a cross-flow fan system with a simplified vortex wall scroll casing and with the published experimental characteristics for a cross-flow fan has been carried out to demonstrate the accuracy of the proposed method. Predicted performance curves by the present mean streamline analysis agree well with experimental data for two different cross-flow fans over the normal operating conditions. The prediction method presented herein can be used efficiently as a tool for the preliminary design and performance analysis of general-purpose cross-flow fans

  10. Genes2FANs: connecting genes through functional association networks

    Science.gov (United States)

    2012-01-01

    Background Protein-protein, cell signaling, metabolic, and transcriptional interaction networks are useful for identifying connections between lists of experimentally identified genes/proteins. However, besides physical or co-expression interactions there are many ways in which pairs of genes, or their protein products, can be associated. By systematically incorporating knowledge on shared properties of genes from diverse sources to build functional association networks (FANs), researchers may be able to identify additional functional interactions between groups of genes that are not readily apparent. Results Genes2FANs is a web based tool and a database that utilizes 14 carefully constructed FANs and a large-scale protein-protein interaction (PPI) network to build subnetworks that connect lists of human and mouse genes. The FANs are created from mammalian gene set libraries where mouse genes are converted to their human orthologs. The tool takes as input a list of human or mouse Entrez gene symbols to produce a subnetwork and a ranked list of intermediate genes that are used to connect the query input list. In addition, users can enter any PubMed search term and then the system automatically converts the returned results to gene lists using GeneRIF. This gene list is then used as input to generate a subnetwork from the user’s PubMed query. As a case study, we applied Genes2FANs to connect disease genes from 90 well-studied disorders. We find an inverse correlation between the counts of links connecting disease genes through PPI and links connecting diseases genes through FANs, separating diseases into two categories. Conclusions Genes2FANs is a useful tool for interpreting the relationships between gene/protein lists in the context of their various functions and networks. Combining functional association interactions with physical PPIs can be useful for revealing new biology and help form hypotheses for further experimentation. Our finding that disease genes in

  11. Should electric fans be used during a heat wave?

    Science.gov (United States)

    Jay, Ollie; Cramer, Matthew N; Ravanelli, Nicholas M; Hodder, Simon G

    2015-01-01

    Heat waves continue to claim lives, with the elderly and poor at greatest risk. A simple and cost-effective intervention is an electric fan, but public health agencies warn against their use despite no evidence refuting their efficacy in heat waves. A conceptual human heat balance model can be used to estimate the evaporative requirement for heat balance, the potential for evaporative heat loss from the skin, and the predicted sweat rate, with and without an electrical fan during heat wave conditions. Using criteria defined by the literature, it is clear that fans increase the predicted critical environmental limits for both the physiological compensation of endogenous/exogenous heat, and the onset of cardiovascular strain by an air temperature of ∼3-4 °C, irrespective of relative humidity (RH) for the young and elderly. Even above these critical limits, fans would apparently still provide marginal benefits at air temperatures as high as 51.1 °C at 10%RH for young adults and 48.1 °C at 10%RH for the elderly. Previous concerns that dehydration would be exacerbated with fan use do not seem likely, except under very hot (>40 °C) and dry (fans by a minor amount (∼20-30 mL/h). Relative to the peak outdoor environmental conditions reported during ten of the most severe heat waves in recent history, fan use would be advisable in all of these situations, even when reducing the predicted maximum sweat output for the elderly. The protective benefit of fans appears to be underestimated by current guidelines. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Performance assessment of a Multi-fuel Hybrid Engine for Future Aircraft

    NARCIS (Netherlands)

    Yin, F.; Gangoli Rao, A.

    2016-01-01

    This paper presents performance assessment of the proposed hybrid engine concept using Liquid Natural Gas (LNG) and kerosene. The multi-fuel hybrid engine is a new engine concept integrated with contra rotating fans, sequential dual combustion chambers to facilitate “Energy Mix” in aviation and a

  13. Performance assessment of a multi-fuel hybrid engine for future aircraft

    NARCIS (Netherlands)

    Yin, F.; Gangoli Rao, A.; Bhat, Abhishek; Chen, Min

    2018-01-01

    This paper presents the performance assessment of a novel turbofan engine using two energy sources: Liquid Natural Gas (LNG) and kerosene, called Multi-Fuel Hybrid Engine (MFHE). The MFHE is a new engine concept consisting of several novel features, such as a contra-rotating fan to sustain

  14. Potential Global Benefits of Improved Ceiling Fan Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Sathaye, Nakul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-31

    Ceiling fans contribute significantly to residential electricity consumption, both in an absolute sense and as a proportion of household consumption in many locations, especially in developing countries in warm climates. However, there has been little detailed assessment of the costs and benefits of efficiency improvement options for ceiling fans and the potential resulting electricity consumption and greenhouse gas (GHG) emissions reductions. We analyze the costs and benefits of several options to improve the efficiency of ceiling fans and assess the global potential for electricity savings and GHG emission reductions with more detailed assessments for India, China, and the U.S. We find that ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terrawatt hours per year (TWh/year) could be saved and 25 million metric tons of carbon dioxide (CO2) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize this savings potential.

  15. Parotid salivary duct stenosis following caudal maxillectomy.

    Science.gov (United States)

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy.

  16. Magnetic resonance imaging of Muellerian duct anomalies in children

    International Nuclear Information System (INIS)

    Li, Yi; Phelps, Andrew; Zapala, Matthew A.; MacKenzie, John D.; MacKenzie, Tippi C.; Courtier, Jesse

    2016-01-01

    Muellerian duct anomalies encompass a wide variety of disorders resulting from abnormalities in the embryological development of the Muellerian ducts. In the prepubertal pediatric population, Muellerian duct anomalies are often incidental findings on studies obtained for other reasons. The onset of menses can prompt more clinical symptoms. Proper characterization of Muellerian duct anomalies is important because these anomalies can affect the development of gynecological disorders as well as fertility. Muellerian duct anomalies also carry a high association with other congenital anomalies, particularly renal abnormalities. MRI is widely considered the best modality for assessing Muellerian duct anomalies; it provides multiplanar capability, clear anatomical detail and tissue characterization without ionizing radiation. MRI allows for careful description of Muellerian duct anomalies, often leading to classification into the most widely accepted classification system for Muellerian duct anomalies. This system, developed by the American Society of Reproductive Medicine, includes seven subtypes: uterine agenesis/hypoplasia, unicornuate, didelphys, bicornuate, septate, arcuate, and diethylstilbestrol (DES) drug-related uterus. In cases of complex anomalies that defy classification, MRI allows detailed depiction of all components of the anatomical abnormality, allowing for proper management and surgical planning. (orig.)

  17. Two studies on the effects of small exhaust fans on indoor air quality: Field study of exhaust fans for mitigating indoor air quality problems; Indoor air quality, exhaust fan mitigation

    International Nuclear Information System (INIS)

    1987-07-01

    Overall, the findings show that exhaust fans basically provide small amounts of ventilation compensation. By monitoring the common indoor air pollutants (radon, formaldehyde, carbon monoxide, nitrogen dioxide, and water vapor), it was found that the quality of the indoor air was not adversely affected by the use of exhaust fans. Nor did their use provide any measurable or significant benefits since no improvement in air quality was ascertained. While exhaust fans of this small size did not increase radon, which is the contaminant of most concern, the researchers caution that operation of a larger fan or installation in a very tight home could result in higher levels because depressurization is greater. The daily energy consumption for use of these appliances during the heating season was calculated to be 1.5 kilowatt hours or approximately 3% of the energy consumption in the study homes. The information collected in this collaborative field study indicates that the use of these particular ventilation systems has no significant effect on indoor air quality

  18. Water condensation promotes fungal growth in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Pasanen, P.; Pasanen, A.-L. (University of Kupopio, Department of Environmental Sciences, Kuopio (Finland)); Jantunen, M. (National Public Health Institute, Kuopio (Finland))

    1993-01-01

    In a subarctic climate the diurnal variation in temperature may cause water condensation in ducts placed in the unheated spaces of a building. In this study, germination time and sporulation of a fungus, Penicillium verrucosum, were studied on dusty, galvanized steel sheet under different moisture conditions at room temperature. The effect of condensed water in a supply air duct on spore amplification was studied in an experimental ventilation set-up. In the field, air temperatures and the dew point temperature of air in the duct were monitored continuously for a week. P. verrucosum germinated on steel surfaces during five-hour incubation of the surface under humid conditions, when the surface has been moist for half an hour, germ tubes appeared within 17 hours. During 24-hour incubation under moist conditions, P. verrucosum produced hyphae and spores. In the experimental set-up the airborne spore counts increased when the air passed through a water-condensing section of the duct. Penicillium was the most abundant fungus sporulated on the moist duct surface. In the field, during humid weather, the surface temperature on the air stream surface decreased to the dew point temperature of the air in the duct. thus water condensation in air ducts may promote fungal growth. (au)

  19. Acoustic Performance of the GEAE UPS Research Fan in the NASA Glenn 9- by 15-Foot Low-Speed Wind Tunnel

    Science.gov (United States)

    Woodward, Richard P.; Hughes, Christopher E.

    2012-01-01

    A model advanced turbofan was acoustically tested in the NASA Glenn 9- by 15-Foot Low-Speed Wind Tunnel in 1994. The Universal Propulsion Simulator fan was designed and manufactured by General Electric Aircraft Engines, and included an active core, as well as bypass, flow paths. The fan was tested with several rotors featuring unswept, forward-swept and aft-swept designs of both metal and composite construction. Sideline acoustic data were taken with both hard and acoustically treated walls in the flow passages. The fan was tested within an airflow at a Mach number of 0.20, which is representative of aircraft takeoff/approach conditions. All rotors showed similar aerodynamic performance. However, the composite rotors typically showed higher noise levels than did corresponding metal rotors. Aft and forward rotor sweep showed at most modest reductions of transonic multiple pure tone levels. However, rotor sweep often introduced increased rotor-stator interaction tone levels. Broadband noise was typically higher for the composite rotors and also for the aft-swept metal rotor. Transonic MPT generation was reduced with increasing fan axis angle of attack (AOA); however, higher downstream noise levels did increase with AOA resulting in higher overall Effective Perceived Noise Level.

  20. Dead links, vaporcuts, and creativity in fan edit replication

    Directory of Open Access Journals (Sweden)

    Joshua Wille

    2015-09-01

    Full Text Available In my examination of a Star Wars prequel trilogy fan edit reportedly made by Topher Grace, I introduce the term vaporcut to describe fan edits with reputations that may generate critical discourse but that are not publicly released. I explore the ways some fan editors attempt to recreate intangible projects but inevitably produce variant works that reflect their own creative perspectives.

  1. Modular Engine Noise Component Prediction System (MCP) Program Users' Guide

    Science.gov (United States)

    Golub, Robert A. (Technical Monitor); Herkes, William H.; Reed, David H.

    2004-01-01

    This is a user's manual for Modular Engine Noise Component Prediction System (MCP). This computer code allows the user to predict turbofan engine noise estimates. The program is based on an empirical procedure that has evolved over many years at The Boeing Company. The data used to develop the procedure include both full-scale engine data and small-scale model data, and include testing done by Boeing, by the engine manufacturers, and by NASA. In order to generate a noise estimate, the user specifies the appropriate engine properties (including both geometry and performance parameters), the microphone locations, the atmospheric conditions, and certain data processing options. The version of the program described here allows the user to predict three components: inlet-radiated fan noise, aft-radiated fan noise, and jet noise. MCP predicts one-third octave band noise levels over the frequency range of 50 to 10,000 Hertz. It also calculates overall sound pressure levels and certain subjective noise metrics (e.g., perceived noise levels).

  2. NOVEL METHODS FOR AXIAL FAN IMPELLER GEOMETRY ANALYSIS AND EXPERIMENTAL INVESTIGATIONS OF THE GENERATED SWIRL TURBULENT FLOW

    Directory of Open Access Journals (Sweden)

    Zoran D Protić

    2010-01-01

    Full Text Available Geometry analysis of the axial fan impeller, experimentally obtained operating characteristics and experimental investigations of the turbulent swirl flow generated behind the impeller are presented in this paper. Formerly designed and manufactured, axial fan impeller blade geometry (originally designed by Prof. Dr-Ing. Z. Protić† has been digitized using a three-dimensional (3D scanner. In parallel, the same impeller has been modeled by beta version software for modeling axial turbomachines, based on modified classical calculation. These results were compared. Then, the axial fan operating characteristics were measured on the standardized test rig in the Laboratory for Hydraulic Machinery and Energy Systems, Faculty of Mechanical Engineering, University of Belgrade. Optimum blade impeller position was determined on the basis of these results. Afterwards, the impeller with optimum angle, without outlet vanes, was positioned in a circular pipe. Rotational speed has been varied in the range from 500 till 2500rpm. Reynolds numbers generated in this way, calculated for axial velocity component, were in the range from 0,8·105 till 6·105. LDA (Laser Doppler Anemometry measurements and stereo PIV (Particle Image Velocimetry measurements of the 3D velocity field in the swirl turbulent fluid flow behind the axial fan have been performed for each regime. Obtained results point out extraordinary complexity of the structure of generated 3D turbulent velocity fields.

  3. The development of a laterally confined laboratory fan delta under sediment supply reduction

    Science.gov (United States)

    Zhang, Xiaofeng; Wang, Siqiang; Wu, Xi; Xu, Shun; Li, Zhangyong

    2016-03-01

    In previous fan delta experiments, the effect of lateral confinement was generally ignored as these fans were usually unconfined with semiconical geometries. However, in gorge areas, fan development is usually laterally confined by valley walls. This study investigates autogenic processes of fan deltas in a laterally confined experimental tank. The experiment is divided into three phases. The sediment supply is held constant within each phase, so the autogenic processes of the fan are separated from the allogenic forcings. Results indicate that laterally confined fan deltas have higher progradation and aggradation potential, more regular channel braiding, and more even transverse sedimentation than unconfined fans. Besides, responses of fan deltas to sediment supply reduction are investigated in this research. At the initiation of the second and third phases, sediment feed rates are instantaneously reduced so that the allogenic forcings are predominant. Observations show that under sediment supply reduction, channelization on fan deltas are more pronounced and durations of the fluvial cycles are longer. The adjustment of fan morphology becomes slower as the self-regulation capacity of the fan decreases with reduced sediment supply.

  4. SWITCHING POWER FAN CONTROL OF COMPUTER

    Directory of Open Access Journals (Sweden)

    Oleksandr I. Popovskyi

    2010-10-01

    Full Text Available Relevance of material presented in the article, due to extensive use of high-performance computers to create modern information systems, including the NAPS of Ukraine. Most computers in NAPS of Ukraine work on Intel Pentium processors at speeds from 600 MHz to 3 GHz and release a lot of heat, which requires the installation of the system unit 2-3 additional fans. The fan is always works on full power, that leads to rapid deterioration and high level (up to 50 dB noise. In order to meet ergonomic requirements it is proposed to іnstall a computer system unit and an additional control unit ventilators, allowing independent control of each fan. The solution is applied at creation of information systems planning research in the National Academy of Pedagogical Sciences of Ukraine on Internet basis.

  5. Risk factors for central bile duct injury complicating partial liver resection

    NARCIS (Netherlands)

    Boonstra, E. A.; de Boer, M. T.; Sieders, E.; Peeters, P. M. J. G.; de Jong, K. P.; Slooff, M. J. H.; Porte, R. J.

    Background: Bile duct injury is a serious complication following liver resection. Few studies have differentiated between leakage from small peripheral bile ducts and central bile duct injury (CBDI), defined as an injury leading to leakage or stenosis of the common bile duct, common hepatic duct,

  6. Fans of Columbine shooters Eric Harris and Dylan Klebold

    Directory of Open Access Journals (Sweden)

    Andrew Ryan Rico

    2015-09-01

    Full Text Available On April 20, 1999, Eric Harris and Dylan Klebold murdered 12 students and one teacher at Columbine High School in Littleton, Colorado, in what was then the deadliest school shooting in American history. Despite causing a national panic and serving as a flash point for larger narratives on bullying, gun control, and media violence, both boys have gained active online fans. These fandoms dedicated to the Columbine shooters are widely referred to as dark examples of Internet communities, while the fans are also frequently denigrated as unstable and violent outcasts. Such dark online fandoms are yet to permeate mainstream culture or to challenge the preexisting perception of these communities as breeding grounds for the next wave of school shooters. While studies have covered the types of fans and their myriad interests, the field remains focused on more conventional examples of fan communities. In an effort to challenge and expand the object of focus when we study fandom, this qualitative study examines Columbine fans and their activity in order to understand the dominant motives they appear to have for engaging with and around such controversial figures and then concludes by exploring how this community might help us reflect more broadly on our concept of fandom. Redeeming these fans as part of diverse and complex communities of social relevance can demonstrate how even a dark fandom such as that of these Columbine shooters provides valuable cultural insights and benefits the field of fan studies.

  7. The benefits of conducting factory performance tests for main mine fans

    Energy Technology Data Exchange (ETDEWEB)

    Ray, R.E.Jr. [PB Americas Inc., New York, NY (United States); Gamble, G.A. [Clarage Twin City Fan Co., Akron, OH (United States)

    2010-07-01

    Axial flow fans used in underground mining are also commonly used in subway tunnel ventilation fans to provide an evacuation path during a tunnel fire emergency. The axial flow fans provide sufficient air velocity to the fire site to prevent backlayering of smoke against the incoming airflow. Since the tunnels are used by the public, advance testing of fans and motors is conducted to confirm that the equipment will perform as specified during a fire. This paper discussed some of the advantages derived from conducting fan factory tests for tunnel projects that would also apply to mining applications. It also described other benefits from testing that are unique to mining. External factors that may cause the fan performance to vary considerably from the predicted performance measured at the factory were also discussed. These included air density changes and system effects produced by poorly designed shaft configurations and fan inlet ductwork. 11 refs., 6 figs.

  8. Flow performance of highly loaded axial fan with bowed rotor blades

    Science.gov (United States)

    Chen, L.; Liu, X. J.; Yang, A. L.; Dai, R.

    2013-12-01

    In this paper, a partial bowed rotor blade was proposed for a newly designed high loaded axial fan. The blade was positively bowed 30 degrees from hub to 30 percent spanwise position. Flows of radial blade and bowed blade fans were numerically compared for various operation conditions. Results show that the fan's performance is improved. At the designed condition with flow coefficient of 0.52, the efficiency of the bowed blade fan is increased 1.44% and the static pressure rise is increased 11%. Comparing the flow structures, it can be found that the separated flow in the bowed fan is reduced and confined within 20 percent span, which is less than the 35 percent in the radial fan. It means that the bowed blade generates negative blade force and counteracts partial centrifugal force. It is alleviates the radial movements of boundary layers in fan's hub region. Flow losses due to 3D mixing are reduced in the rotor. Inlet flow to downstream stator is also improved.

  9. 30 CFR 57.4131 - Surface fan installations and mine openings.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Surface fan installations and mine openings. 57... Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4131 Surface fan installations... stored within 100 feet of mine openings or within 100 feet of fan installations used for underground...

  10. 30 CFR 57.22203 - Main fan operation (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main fan operation (I-C mines). 57.22203... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22203 Main fan operation (I-C mines). Main fans shall be operated continuously while ore production is in progress. ...

  11. WAVE PROPAGATION in the HOT DUCT of VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Richard Schultz; Jim C. P. Liou

    2013-07-01

    In VHTR, helium from the reactor vessel is conveyed to a power conversion unit through a hot duct. In a hypothesized Depressurized Conduction Cooldown event where a rupture of the hot duct occurs, pressure waves will be initiated and reverberate in the hot duct. A numerical model is developed to quantify the transients and the helium mass flux through the rupture for such events. The flow path of the helium forms a closed loop but only the hot duct is modeled in this study. The lower plum of the reactor vessel and the steam generator are treated as specified pressure and/or temperature boundary to the hot duct. The model is based on the conservation principles of mass, momentum and energy, and on the equations of state for helium. The numerical solution is based on the method of characteristics with specified time intervals with a predictor and corrector algorithm. The rupture sub-model gives reasonable results. Transients induced by ruptures with break area equaling 20%, 10%, and 5% of the duct cross-sectional area are described.

  12. Imaging manifestation of hepatocellular carcinoma with bile duct tumor thrombi

    International Nuclear Information System (INIS)

    Liu Qingyu; Chen Jianyu; Liang Biling; Hu Tao

    2008-01-01

    Objective: To analyze the imaging features of hepatocellular carcinoma(HCC) with bile duct tumor thrombi. Methods: Thirteen patients with bile duct tumor thrombi proved pathologically underwent imaging examination. MR and CT were performed in 3 cases, and 2 cases had CT only and 8 cases had MRI only. Ultrasonography(US) was performed in all 13 patients. The accuracy of bile duct tumor thrombi detection was compared between US, CT and MRI with Fisher test. Results: Liver tumors and bile duct tumor thrombi were demonstrated in all patients on CT or MRI. Presence of intraluminal soft tissue mass was found in four of five cases on CT, and mild enhancement of the intraluminal mass in the arterial phase was noted, dilated bile duct distal to tumor thrombi was detected in all five patients. Eleven Tumor thrombi showed slight low signal intensity on T 1 WI, slight high signal intensity on T 2 WI, and mild to moderate contrast enhancement on the contrast-enhanced MR images. The MRCP findings of tumor thrombi were as follows: interruption, stricture of the bile ducts or irregular filling defect in the bile ducts with dilated intrahepatic ducts, bile duet was abruptly interrupted or showed a 'rat-tail' stricture (n=5); the common bile duct was filled with tumor thrombi, intrahepatic bile duct dilatation and missing common bile duct was noted on MRCP (n=2). Bile duct tumor thrombi were correctly diagnosed in 7 cases on US, and 12 cases on CT or MRI. Six cases were misdiagnosed or miss-diagnosed on US, and 4 cases were misdiagnosed on CT or MRI. There was no significant difference between US and CT/MRI in diagnosis of bile duct tumor thrombi (P=0.270). Conclusion: CT or MR imaging is useful for the diagnosis of HCC with biliary tumor thrombi and for evaluating the extension of thrombi. (authors)

  13. Performance Testing Of A Modified Centrifugal Fan With Serrated Blade Impeller

    Directory of Open Access Journals (Sweden)

    Zaimar

    2017-10-01

    Full Text Available Changes of shape dimension and component part of impeller might change of characteristic fluid flow so that pressure static in the fan housing changed. Changing some geometric characteristics of the centrifugal fan has more efficiency taking with energy crises into consideration. Several factors that can affect fan performance namely design and type size rotation speed air condition or gas through a fan operating point on the nature of the relationship between a volume of air flow and pressure. The purpose of this research was to test of fan performance of the modified centrifugal fan with the serrated blade impeller. The addition of a percentage of closing the inlet causes the air volumetric rate the airflow energy BHP and total efficiency except for the fan total and static pressure. The experimental test results there are static pressure data and the resulting total pressure is different or distorted 10-17 of deviation from calculation data based on the fan laws. This is possible because of changes in the shape of the blade with serrated on the inside of the impeller. Based on the performance curve shows that the selection of impeller speeds of 800 RPM produces a relatively high air volumetric rate is proportional to the total pressure of the fan and the flow energy so that it is more efficient than other impeller speeds.

  14. Large Fluvial Fans: Aspects of the Attribute Array

    Science.gov (United States)

    Wilkinson, Justin M.

    2015-01-01

    In arguing for a strict definition of the alluvial fan (coarse-grained with radii less than10 km, in mountain-front settings), Blair and McPherson (1994) proposed that there is no meaningful difference between large fluvial fans (LFF) and floodplains, because the building blocks of both are channel-levee-overbank deposits. Sediment bodies at the LFF scale (greater than 100 km long, fan-shaped in planform), are relatively unstudied although greater than 160 are now identified globally. The following perspectives suggest that the significance of LFF needs to be reconsidered.

  15. Gender constructions and negotiations of female football fans

    DEFF Research Database (Denmark)

    Lenneis, Verena; Pfister, Gertrud Ursula

    2015-01-01

    While both the media and the academic literature focus primarily on male fans, in particular on violence and the prevention of hooliganism, little is known about female football supporters. This is also true of Denmark, a country that is known for its high degree of gender equality. This article...... aims to give insight into gender constructions and negotiations of female football fans in the stands. Drawing on a social constructivist perspective to gender and Bourdieu's (1984) approaches to field, capital and habitus, we explored the experiences and opinions of female fans. The methods employed...

  16. Precautions against axial fan stall in reactor building to Tianwan NPP

    International Nuclear Information System (INIS)

    Liu Chunlong; Pei Junmin

    2011-01-01

    The paper introduces the mechanism and harm of rotating stall of axial fans, analyzes the necessity for prevention against axial fan stall in reactor building of Tianwan NPP, introduces the precautions, and then makes an assessment on anti-stall effect of flow separators. It can provide reference for model-selection or reconstruction of similar fans in power stations, and for operation and maintenance of axial fans. (authors)

  17. Bile duct anastomotic stricture after pediatric living donor liver transplantation.

    Science.gov (United States)

    Chok, Kenneth S H; Chan, See Ching; Chan, Kwong Leung; Sharr, William W; Tam, Paul K H; Fan, Sheung Tat; Lo, Chung Mau

    2012-07-01

    Hepaticojejunostomy is a well-accepted method, whereas duct-to-duct anastomosis is gaining popularity for bile duct reconstruction in pediatric living donor liver transplantation (LDLT). Biliary complications, especially biliary anastomotic stricture (BAS), are not clearly defined. The aim of the present study is to determine the rate of BAS and its associated risk factors. The study included 78 pediatric patients (duct-to-duct anastomosis during LDLT. The median follow-up period for the BAS group and the non-BAS group was 57.8 and 79.5 months, respectively (P = .683). Ten of the patients with BAS required percutaneous transhepatic biliary drainage with or without dilatation for treating the stricture. Multivariable analysis showed that hepatic artery thrombosis and duct-to-duct anastomosis were 2 risk factors associated with BAS. In pediatric LDLT, hepaticojejunostomy is the preferred method for bile duct reconstruction, but more large-scale research needs to be done to reconfirm this result. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  19. Portable Life Support System 2.5 Fan Design and Development

    Science.gov (United States)

    Quinn, Gregory; Carra, Michael; Converse, David; Chullen, Cinda

    2016-01-01

    NASA is building a high-fidelity prototype of an advanced Portable Life Support System (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, was driven by a centrifugal fan developed using specifications from the Constellation Program. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement were identified with the PLSS 2.0 fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0, and it uses the same nonmetallic, canned motor, with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 ventilation loop. The larger impeller allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds consistent with prior, oxygen-rated fans. Development of the fan also considered a shrouded impeller design that could allow larger clearances for greater oxygen safety, assembly tolerances and particle ingestion. This paper discusses the design, manufacturing and performance testing of the new fans.

  20. A Comparison of Simulation Capabilities for Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Smith, Matt K [ORNL; Gu, Lixing [Florida Solar Energy Center (FSEC); New, Joshua Ryan [ORNL

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  1. On-chip grating coupler array on the SOI platform for fan-in/fan-out of multi-core fibers with low insertion loss and crosstalk

    DEFF Research Database (Denmark)

    Ding, Yunhong; Ye, Feihong; Peucheret, Christophe

    2014-01-01

    We design and fabricate a compact multi-core fiber fan-in/fan-out using a fully-etched grating coupler array on the SOI platform. Lowest coupling loss of 6.8 dB with 3 dB bandwidth of 48 nm and crosstalk lower than ×32 dB are demonstrated.......We design and fabricate a compact multi-core fiber fan-in/fan-out using a fully-etched grating coupler array on the SOI platform. Lowest coupling loss of 6.8 dB with 3 dB bandwidth of 48 nm and crosstalk lower than ×32 dB are demonstrated....

  2. Optimization of the Hockey Fans in Training (Hockey FIT) weight loss and healthy lifestyle program for male hockey fans.

    Science.gov (United States)

    Blunt, Wendy; Gill, Dawn P; Sibbald, Shannon L; Riggin, Brendan; Pulford, Roseanne W; Scott, Ryan; Danylchuk, Karen; Gray, Cindy M; Wyke, Sally; Bunn, Christopher; Petrella, Robert J

    2017-11-28

    The health outcomes of men continue to be poorer than women globally. Challenges in addressing this problem include difficulties engaging men in weight loss programs as they tend to view these programs as contrary to the masculine narrative of independence and self-reliance. Researchers have been turning towards sports fans to engage men in health promotion programs as sports fans are typically male, and tend to have poor health habits. Developed from the highly successful gender-sensitized Football Fans in Training program, Hockey Fans in Training (Hockey FIT) recruited 80 male hockey fans of the London Knights and Sarnia Sting who were overweight or obese into a weekly, 90-minute classroom education and group exercise program held over 12 weeks; a 40-week minimally-supported phase followed. A process evaluation of the Hockey FIT program was completed alongside a pragmatic randomized controlled trial and outcome evaluation in order to fully explore the acceptability of the Hockey FIT program from the perspectives of coaches delivering and participants engaged in the program. Data sources included attendance records, participant focus groups, coach interviews, assessment of fidelity (program observations and post-session coach reflections), and 12-month participant interviews. Coaches enjoyed delivering the program and found it simple to deliver. Men valued being among others of similar body shape and similar weight loss goals, and found the knowledge they gained through the program helped them to make and maintain health behaviour changes. Suggested improvements include having more hockey-related information and activities, greater flexibility with timing of program delivery, and greater promotion of technology support tools. We confirmed Hockey FIT was an acceptable "gender-sensitized" health promotion program for male hockey fans who were overweight or obese. Minor changes were required for optimization, which will be evaluated in a future definitive trial

  3. Parametric study of electromagnetic waves propagating in absorbing curved S ducts

    Science.gov (United States)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.

  4. Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version

    Science.gov (United States)

    Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.

  5. A radiographic study of nasopalatine duct cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1993-02-15

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  6. A radiographic study of nasopalatine duct cysts

    International Nuclear Information System (INIS)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae

    1993-01-01

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  7. Upper Pleistocene turbidite sand beds and chaotic silt beds in the channelized, distal, outer-fan lobes of the Mississippi fan

    Science.gov (United States)

    Nelson, C.H.; Twichell, D.C.; Schwab, W.C.; Lee, H.J.; Kenyon, Neil H.

    1992-01-01

    Cores from a Mississippi outer-fan depositional lobe demonstrate that sublobes at the distal edge contain a complex local network of channelized-turbidite beds of graded sand and debris-flow beds of chaotic silt. Off-lobe basin plains lack siliciclastic coarse-grained beds. The basin-plain mud facies exhibit low acoustic backscatter on SeaMARC IA sidescan sonar images, whereas high acoustic backscatter characteristic of the lobe sand and silt facies. The depth of the first sand-silt layer correlates with relative backscatter intensity and stratigraphic age of the distal sublobes (i.e., shallowest sand = highest backscatter and youngest sublobe). The high proportion (>50%) of chaotic silt compared to graded sand in the distal, outer-fan sublobes may be related to the unstable, muddy, canyon-wall source areas of the extensive Mississippi delta-fed basin slope. A predominace of chaotic silt in cores or outcrops from outer-fan lobes thus may predict similar settings for ancient fans.

  8. Measure Guideline. Sealing and Insulating Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Puttagunta, S. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  9. 77 FR 16139 - Airworthiness Directives; Pratt & Whitney (PW) Turbofan Engines

    Science.gov (United States)

    2012-03-20

    ... Airworthiness Directives; Pratt & Whitney (PW) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... & Whitney (PW) PW2037, PW2037(M), and PW2040 turbofan engines with certain fan blades with a cutback leading..., PW2040, PW2240, PW2337 Turbofan Engine Manual, Part No. 1A6231, Chapter/Section 72-31-12, Repair-14 and...

  10. 30 CFR 75.312 - Main mine fan examinations and records.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main mine fan examinations and records. 75.312... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.312 Main mine fan examinations and records. (a) To assure electrical and mechanical reliability of main mine fans, each main mine...

  11. Representation of American versus non-American fans in Baillie Walsh's Springsteen & I

    NARCIS (Netherlands)

    Wilkinson, M.C.

    2015-01-01

    This article explores the representation of American versus non-American fans in Baillie Walsh's 2013 crowd/fan-sourced documentary Springsteen & I. The film—as much as it was fed by a wide and international range of fan-produced material—ultimately produced and presented one particular type of fan

  12. Costs and benefits of energy efficiency improvements in ceiling fans

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar; Sathaye, Nakul; Phadke, Amol; Letschert, Virginie [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15

    Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

  13. Sports Fans, Alcohol Use, and Violent Behavior: A Sociological Review.

    Science.gov (United States)

    Ostrowsky, Michael K

    2016-08-31

    This review makes four contributions to the sociological study of sports fans, alcohol use, and violent behavior. First, this article focuses explicitly on the relationship between alcohol use and violent behavior among sports fans. This is a worldwide social problem, yet it is quite understudied. Second, this article synthesizes the fragmented literature on alcohol use and violent behavior among sports fans. Third, this article identifies four broad sets of risk factors-sociocultural, event/venue, police, and crowd-that appear to be closely related to violent behavior among sports fans. Finally, to help explain the possible correlation between alcohol and violence among sports fans, this article draws upon the key understandings from the literature on alcohol and violence in wider society. The article concludes with suggestions for future research. © The Author(s) 2016.

  14. A case of fascioliasis in common bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-10-15

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct.

  15. A case of fascioliasis in common bile duct

    International Nuclear Information System (INIS)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong

    1989-01-01

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct

  16. Treatment Options for Extrahepatic Bile Duct Cancer

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  17. Treatment Option Overview (Extrahepatic Bile Duct Cancer)

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  18. General Information about Extrahepatic Bile Duct Cancer

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  19. Influence of wind velocity fluctuation on air temperature difference between the fan and ground levels and the effect of frost protective fan operation

    International Nuclear Information System (INIS)

    Araki, T.; Matsuo, K.; Miyama, D.; Sumikawa, O.; Araki, S.

    2008-01-01

    We invested the influence of wind velocity fluctuation on air temperature difference between the fan (4.8 m) and ground levels (0.5 m) and the effect of frost protective fan operation in order to develop a new method to reduce electricity consumption due to frost protective fan operation. The results of the investigations are summarized as follows: (1) Air temperature difference between the fan (4.8 m) and ground levels (0.5 m) was decreased following an increase in wind velocity, and the difference was less than 1°C for a wind velocity more than 3.0 m/s at a height of 6.5 m. (2) When the wind velocity was more than 2-3 m/s, there was hardly any increase in the temperature of the leaves. In contrast, when the wind velocity was less than 2-3 m/s, an increase in the temperature of the leaves was observed. Based on these results, it is possible that when the wind velocity is greater than 2-3 m, it prevents thermal inversion. Therefore, there would be no warmer air for the frost protective fan to return to the tea plants and the air turbulence produced by the frost protective fan would not reach the plants under the windy condition

  20. A Case of Adenomyomatous Hyperplasia of the Extrahepatic Bile Duct

    Directory of Open Access Journals (Sweden)

    Masakatsu Numata

    2011-08-01

    Full Text Available Adenomyomatous hyperplasia is rarely found in the extrahepatic bile duct. A 54-year-old man was referred to our center with a diagnosis of extrahepatic bile duct stenosis which had been detected by endoscopic retrograde choloangiopancreatography. Abdominal computed tomography revealed thickening of the wall of the middle extrahepatic bile duct, however no malignant cells were detected by cytology. Since bile duct carcinoma could not be ruled out, we performed resection of the extrahepatic duct accompanied by lymph node dissection. Histopathologically, the lesion was diagnosed as adenomyomatous hyperplasia of the extrahepatic bile duct. Present and previously reported cases showed the difficulty of making a diagnosis of adenomyomatous hyperplasia of the extrahepatic bile duct preoperatively or intraoperatively. Therefore, when adenomyomatous hyperplasia is suspected, a radical surgical procedure according to malignant disease may be necessary for definitive diagnosis.

  1. "The florals": Female fans over 50 in the Sherlock fandom

    Directory of Open Access Journals (Sweden)

    Line Nybro Petersen

    2017-03-01

    Full Text Available This article uses e-mail interviews with nine female fans to explore what it means to be a fan over the age of 50 of the popular BBC drama Sherlock (2010–. The research aims to better understand the role of fandom in later life, in particular how the participants in this study negotiate their perceptions of their subjective age in relation to being a fan in this part of their life course. This study combines theory on cultural gerontology with fan studies and mediatization theory in order to understand the dynamics and processes that guide fans' negotiations of subjective age as well as the role of fan practices and the affordances of social media in these processes. I argue that fandom, as a manifestation of a mediatized culture, augments the relevance of subjective age and informs the way in which participants in middle and later life perceive and negotiate their own subjective age specifically in relation to fandom as youth culture, women's passion, and creativity.

  2. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    Science.gov (United States)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  3. U. S. programs on reference and advanced cladding/duct materials

    International Nuclear Information System (INIS)

    Bennett, J.W.; Holmes, J.J.; Laidler, J.J.

    1977-05-01

    Two coordinated national programs are presently in place in the United States for development of reference and advanced cladding and duct alloys for near-term and long-term LMFBR applications. A number of government, industrial and university laboratories are active participants in these two ERDA-sponsored programs. The programs are administered by ERDA through a task group organization, with each task group representing a particular technical activity and the membership of the task group drawn from among the laboratories with active involvement in that activity. Technical coordination of the two programs is provided by the Hanford Engineering Development Laboratory. The National Reference Cladding and Duct Program is charged with the responsibility for development of the required technology to permit full utilization of the reference material, 20 percent cold-worked Type 316 stainless steel, in early LMFBR core applications. The current schedule calls for full evaluation of FFTF-related design base data prior to full-power operation of FFTF in early 1980, followed by a confirmation in early 1983 of reference material performance capabilities for initial-core CRBRP applications. Comprehensive evaluation of reference material performance to commercial plant goal fluence levels will be complete by 1985. The National Advanced Alloy Development Program was instituted in 1974 with the objective to develop, by 1986, advanced cladding and duct materials compatible with advanced fuel systems having peak burnup capabilities up to 150 MWD/kg and doubling times of 15 years or less. Screening of a large number of potential alloys was completed in mid-1975, and there are presently 16 candidate alloys under active investigation

  4. Flow performance of highly loaded axial fan with bowed rotor blades

    International Nuclear Information System (INIS)

    Chen, L; Liu, X J; Yang, A L; Dai, R

    2013-01-01

    In this paper, a partial bowed rotor blade was proposed for a newly designed high loaded axial fan. The blade was positively bowed 30 degrees from hub to 30 percent spanwise position. Flows of radial blade and bowed blade fans were numerically compared for various operation conditions. Results show that the fan's performance is improved. At the designed condition with flow coefficient of 0.52, the efficiency of the bowed blade fan is increased 1.44% and the static pressure rise is increased 11%. Comparing the flow structures, it can be found that the separated flow in the bowed fan is reduced and confined within 20 percent span, which is less than the 35 percent in the radial fan. It means that the bowed blade generates negative blade force and counteracts partial centrifugal force. It is alleviates the radial movements of boundary layers in fan's hub region. Flow losses due to 3D mixing are reduced in the rotor. Inlet flow to downstream stator is also improved

  5. Morphology and sedimentology of glacigenic submarine fans on the west Greenland continental margin

    Science.gov (United States)

    O'Cofaigh, Colm; Hogan, Kelly A.; Dowdeswell, Julian A.; Jennings, Anne E.; Noormets, Riko; Evans, Jeffrey

    2014-05-01

    Along the West Greenland continental margin adjoining Baffin Bay, bathymetric data show a series of large submarine fans located at the mouths of cross-shelf troughs. Two of these fans, the Uummannaq Fan and the Disko Fan are trough-mouth fans built largely of debris delivered from ice sheet outlets of the Greenland Ice Sheet during past glacial maxima. On the Uummannaq Fan glacigenic debris flow deposits occur on the upper slope and extend to at least 1800 m water depth in front of the trough-mouth. The debris flow deposits are related to the remobilisation of subglacial debris that was delivered onto the upper slope at times when an ice stream was positioned at the shelf edge. In contrast, sedimentary facies from the northern sector of the fan are characterised by hemipelagic and ice-rafted sediments and turbidites; glacigenic debris flows are notably absent in cores from this region. Further south along the Greenland continental margin the surface of the Disko Fan is prominently channelised and associated sediments are acoustically stratified. Although glacigenic debris flow deposits do occur on the upper Disko Fan, sediments recovered in cores from elsewhere on the fan record the influence of turbidity current and meltwater sedimentation. The channelised form of the Disko fan contrasts markedly with that of the Uummannaq Fan and, more widely, with trough mouth fans from the Polar North Atlantic. Collectively these data highlight the variability of glacimarine depositional processes operating on trough-mouth fans on high-latitude continental slopes and show that glacigenic debris flows are but one of a number of mechanisms by which such large glacially-influenced depocentres form.

  6. Hepatocellular carcinoma with bile duct involvement : computed Tomographic (CT) findings

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Han, Joon Koo; Kim, Tae Kyoung; And others

    2000-01-01

    To describe the radiologic features of computed tomography (CT) in hepatocellular carcinoma (HCC) with bile duct involvement. We retrospectively analyzed the two phase spiral CT findings of 31 patients in whom HCC with bile duct invasion (n=3D28) or compression (n=3D3), was diagnosed. Eight of these underwent follow up CT after transarterial chemoembolization. We analyzed the size, type, location, enhancement pattern, and lipiodol retention of parenchymal and intraductal masses, as well as their lymphadenopathy. In all patients with bile duct invasion, single or multiple masses were demonstrated in the bile ducts. Intraductal masses showed the same enhancement characteristics as the parenchymal mass (kappa 0.550, p less than 0.001), and were contiguous to this mass. In 14 of 28 patients, intraductal masses filled the peripheral intrahepatic bile ducts and extended to the common bile ducts. In the other 14, the parenchymal mass extended to the area of the porta hepatis and then directly invaded the large ducts. In nine of the 28 patients, there was a hypoattenuated cleft between the intraductal mass and ductal wall. In six, a parenchymal mass was not apparent (n=3D2), or was smaller than 2cm (n=3D4). In five of eight patients (62.5%), follow-up CT after transarterial chemoembolization showed compact or partial lipiodol retention within the intraductal mass. In patients with bile duct compression, perihilar lymph nodes were noted along with the dilated intrahepatic duct but no intra ductal mass was demonstrated in the duct. Hepatocellular carcinomas cause bile duct dilatation either by direct invasion or by extrinsic compression of the bile duct with surrounding enlarged nodes. For the diagnosis of this condition, CT is helpful. (author)

  7. Self-made metal stent in treatment of nasolacrimal duct obstruction

    International Nuclear Information System (INIS)

    Du Wei; Pang Ruilin; Luo Gang; Gu Jingchuan; Gong Yongxiang

    2003-01-01

    Objective: To evaluate application of self-made metal stent in treatment of nasolacrimal duct obstruction. Methods: In total 15 cases, self-made metal stents made of stainless steel wire were implanted in 18 obstructed nasolacrimal ducts. The lacrimal passages were rinsed and re-canalized followed by antegrade inserting the guide wire from upper dacryon. A dilator was inserted over the guide wire, and then a stent was released from a sheath into the impaired section of nasolacrimal duct. Dacryocystography was performed before and after the interventional procedure. Results: Dacryocystography showed patent nasolacrimal duct after treatment. Epiphora disappeared completely in 11 cases (13 ducts), improved in 4 cases (5 ducts). These cases had been followed up for 61-219 days (167 days in average). Relapse was found in 2 cases (2 ducts) in three months. Those 2 stents were removed by surgical procedure and found occluded by granulation. Conclusion: Interventional placement of the self-made metal stent is a simple, safe, low-cost and effective treatment of the nasolacrimal duct obstruction

  8. Multiple view fan beam polarimetry on Tokamak devices

    International Nuclear Information System (INIS)

    Geck, W.R.; Domier, C.W.; Luhmann, N.C.

    1997-01-01

    A polarimeter diagnostic is under development which utilizes several fan beams to accumulate line integrated Faraday rotation data in a Tokamak plasma. The utilization of a fan beam configuration over that of conventional vertical view polarimeter systems significantly reduces access requirements. The high angular separation inherent in a fan beam implementation increases plasma coverage and eliminates the necessity of assumed plasma symmetries to generate high quality current density profiles. Codes have been developed to generate these high-resolution two-dimensional images of the plasma current profile from data collected at arbitrary positions and viewing angles. copyright 1997 American Institute of Physics

  9. Cystic duct remnant mucocele in a liver transplant recipient

    International Nuclear Information System (INIS)

    Ahlawat, Sushil K.; Fishbien, Thomas M.; Haddad, Nadim G.

    2008-01-01

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  10. Cystic duct remnant mucocele in a liver transplant recipient

    Energy Technology Data Exchange (ETDEWEB)

    Ahlawat, Sushil K. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); University of Medicine and Dentistry of New Jersey, New Jersey Medical School, Newark, NJ (United States); Fishbien, Thomas M. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); Haddad, Nadim G. [Georgetown University Hospital, Department of Surgery, Division of Transplant Surgery, Washington, DC (United States)

    2008-08-15

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  11. Fan-structure wave as a source of earthquake instability

    Science.gov (United States)

    Tarasov, Boris

    2015-04-01

    Today frictional shear resistance along pre-existing faults is considered to be the lower limit on rock shear strength at confined compression corresponding to the seismogenic layer. This determines the lithospheric strength and the primary earthquake mechanism associated with frictional stick-slip instability on pre-existing faults. This paper introduces a recently identified shear rupture mechanism providing a paradoxical feature of hard rocks - the possibility of shear rupture propagation through the highly confined intact rock mass at shear stress levels significantly less than frictional strength. In the new mechanism the rock failure, associated with consecutive creation of small slabs (known as 'domino-blocks') from the intact rock in the rupture tip, is driven by a fan-shaped domino structure representing the rupture head. The fan-head combines such unique features as: extremely low shear resistance (below the frictional strength), self-sustaining stress intensification in the rupture tip (providing easy formation of new domino-blocks), and self-unbalancing conditions in the fan-head (making the failure process inevitably spontaneous and violent). An important feature of the fan-mechanism is the fact that for the initial formation of the fan-structure an enhanced local shear stress is required, however, after completion of the fan-structure it can propagate as a dynamic wave through intact rock mass at shear stresses below the frictional strength. Paradoxically low shear strength of pristine rocks provided by the fan-mechanism determines the lower limit of the lithospheric strength and favours the generation of new faults in pristine rocks in preference to frictional stick-slip instability along pre-existing faults. The new approach reveals an alternative role of pre-existing faults in earthquake activity: they represent local stress concentrates in pristine rock adjoining the fault where special conditions for the fan-mechanism nucleation are created

  12. Using Innovative Techniques for Manufacturing Rocket Engine Hardware

    Science.gov (United States)

    Betts, Erin M.; Reynolds, David C.; Eddleman, David E.; Hardin, Andy

    2011-01-01

    Many of the manufacturing techniques that are currently used for rocket engine component production are traditional methods that have been proven through years of experience and historical precedence. As we enter into a new space age where new launch vehicles are being designed and propulsion systems are being improved upon, it is sometimes necessary to adopt new and innovative techniques for manufacturing hardware. With a heavy emphasis on cost reduction and improvements in manufacturing time, manufacturing techniques such as Direct Metal Laser Sintering (DMLS) are being adopted and evaluated for their use on J-2X, with hopes of employing this technology on a wide variety of future projects. DMLS has the potential to significantly reduce the processing time and cost of engine hardware, while achieving desirable material properties by using a layered powder metal manufacturing process in order to produce complex part geometries. Marshall Space Flight Center (MSFC) has recently hot-fire tested a J-2X gas generator discharge duct that was manufactured using DMLS. The duct was inspected and proof tested prior to the hot-fire test. Using the Workhorse Gas Generator (WHGG) test setup at MSFC?s East Test Area test stand 116, the duct was subject to extreme J-2X gas generator environments and endured a total of 538 seconds of hot-fire time. The duct survived the testing and was inspected after the test. DMLS manufacturing has proven to be a viable option for manufacturing rocket engine hardware, and further development and use of this manufacturing method is recommended.

  13. Bowing-reactivity trends in EBR-II assuming zero-swelling ducts

    International Nuclear Information System (INIS)

    Meneghetti, D.

    1994-01-01

    Predicted trends of duct-bowing reactivities for the Experimental Breeder Reactor II (EBR-II) are correlated with predicted row-wise duct deflections assuming use of idealized zero-void-swelling subassembly ducts. These assume no irradiation induced swellings of ducts but include estimates of the effects of irradiation-creep relaxation of thermally induced bowing stresses. The results illustrate the manners in which at-power creeps may affect subsequent duct deflections at zero power and thereby the trends of the bowing component of a subsequent power reactivity decrement

  14. [Bile duct lesions in laparoscopic cholecystectomy].

    Science.gov (United States)

    Siewert, J R; Ungeheuer, A; Feussner, H

    1994-09-01

    Laparoscopic cholecystectomy is both resulting in a slightly higher incidence of biliary lesions and a change of prevalence of the type of lesions. Damage to the biliary system occurs in 4 different types: The most severe case is the lesion with a structural defect of the hepatic or common bile duct with (IVa) or without (IVb) vascular injury. Tangential lesions without structural loss of the duct should be denominated as type III (IIIa with additional lesion to the vessels, type IIIb without). Type II comprehends late strictures without obvious intraoperative trauma to the duct. Type I includes immediate biliary fistulae of usually good prognosis. The increasing prevalence of structural defects of the bile ducts appears to be a peculiarity of laparoscopic cholecystectomy necessitating highly demanding operative repair. In the majority of cases, hepatico-jejunostomy or even intraparenchymatous anastomoses are required. Adaptation of well proven principles of open surgery is the best prevention of biliary lesions in laparoscopic cholecystectomy as well as the readiness to convert early to the open procedure.

  15. K-pop Reception and Participatory Fan Culture in Austria

    OpenAIRE

    Sang-Yeon Sung

    2013-01-01

    K-pop’s popularity and its participatory fan culture have expanded beyond Asia and become significant in Europe in the past few years. After South Korean pop singer Psy’s “Gangnam Style” music video topped the Austrian chart in October 2012, the number and size of K-pop events in Austria sharply increased, with fans organizing various participatory events, including K-pop auditions, dance festivals, club meetings, quiz competitions, dance workshops, and smaller fan-culture gatherings. In the ...

  16. 78 FR 50320 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-08-19

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... Electric Company (GE) model GEnx-2B67B turbofan engines with booster anti-ice (BAI) air duct, part number...-2B67 turbofan engine be removed from the Applicability section of this AD. The commenters noted that...

  17. Ultrasound appearance of chronic mammary duct ectasia

    Energy Technology Data Exchange (ETDEWEB)

    Duchesne, N. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)]. E-mail: nathalie_duchesne_22@yahoo.ca; Skolnik, S. [Univ. of Toronto, Dept. of Family Medicine, Toronto, Ontario (Canada); Bilmer, S. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)

    2005-12-15

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  18. Ultrasound appearance of chronic mammary duct ectasia

    International Nuclear Information System (INIS)

    Duchesne, N.; Skolnik, S.; Bilmer, S.

    2005-01-01

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  19. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is

  20. Electric fans for reducing adverse health impacts in heatwaves.

    Science.gov (United States)

    Gupta, Saurabh; Carmichael, Catriona; Simpson, Christina; Clarke, Mike J; Allen, Claire; Gao, Yang; Chan, Emily Y Y; Murray, Virginia

    2012-07-11

    Heatwaves are hot weather events, which breach regional or national thresholds, that last for several days. They are likely to occur with increasing frequency in some parts of the world. The potential consequences were illustrated in Europe in August 2003 when there were an estimated 30,000 excess deaths due to a heatwave. Electric fans might be used with the intention of reducing the adverse health effects of a heatwave. Fans do not cool the ambient air but can be used to draw in cooler air from outside when placed at an open window. The aim of the fans would be to increase heat loss by increasing the efficiency of all normal methods of heat loss, but particularly by evaporation and convection methods. However, it should be noted that increased sweating can lead to dehydration and electrolyte imbalances if these fluids and electrolytes are not replaced quickly enough. Research has also identified important gaps in knowledge about the use of fans, which might lead to their inappropriate use. To determine whether the use of electric fans contributes to, or impedes, heat loss at high ambient temperatures during a heatwave, and to contribute to the evidence base for the public health impacts of heatwaves. We sought unpublished and published studies that had been published in any language. The review team were able to assess studies reported in English, Chinese, Dutch, French and German; and reports in other languages would have been translated into English as necessary. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, CINAHL, the Indian biomedical literature (IndMED and MedIND) and databases of Chinese literature (Chinese Journal Net and Digital Periodical of WanFang Data). The most recent electronic searches were done in April 2012. We also checked the reference lists of relevant articles and the websites of relevant national and international organisations, and consulted with researchers and policy makers with experience in