  1. Ducted fuel injection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Charles J.

    2018-03-06

    Various technologies presented herein relate to enhancing mixing inside a combustion chamber to form one or more locally premixed mixtures comprising fuel and charge-gas with low peak fuel to charge-gas ratios to enable minimal, or no, generation of soot and other undesired emissions during ignition and subsequent combustion of the locally premixed mixtures. To enable sufficient mixing of the fuel and charge-gas, a jet of fuel can be directed to pass through a bore of a duct causing charge-gas to be drawn into the bore creating turbulence to mix the fuel and the drawn charge-gas. The duct can be located proximate to an opening in a tip of a fuel injector. The duct can comprise of one or more holes along its length to enable charge-gas to be drawn into the bore, and further, the duct can cool the fuel and/or charge-gas prior to combustion.

  2. Optimum design of the injection duct system of a stenter machine

    Energy Technology Data Exchange (ETDEWEB)

    Juraeva, Makhsuda; Song, Dong Joo [Yeungnam University, Geyongsan (Korea, Republic of); Ryu, Kyung Jin [Ajou Motor College, Boryeong (Korea, Republic of)

    2017-05-15

    Stenter machines are used for drying fabrics in the textile industry and have a heater, injection duct system, and fans inside a chamber. The injection duct system has ducts and air-injecting holes. Plane-type injection duct systems were investigated to obtain uniform airflow at the air-injecting holes. The flow field of the injection duct systems was computed using ANSYS CFX with different heights of the duct end and different shapes for the air-injecting holes. There was a high mass flow rate at the air-injecting holes and high airflow circulation inside both plane-type and mountain-type ducts at the ends. The height of the duct end was varied between 40 mm and 160 mm. The injection duct systems were analyzed with four different shapes of air-injecting holes. The circular and elliptical holes had lower standard deviations of the mass flow rate than other shapes. Relatively uniform mass flow rates were obtained in the plane-type and mountain-type duct systems when the height of the duct end was 40 mm and the shape of the air-injecting holes was circular or elliptical. The developed injection duct systems were improved by obtaining a uniform mass flow rate at the air-injecting holes. A stenter prototype was fabricated with the developed injection duct system to confirm the numerical results. The developed injection duct system had better performance than the original system.

  3. High SO{sub 2} removal duct injection: A low-cost FGD alternative

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, S.G. [Sorbent Technologies Corp., Twinsburg, OH (United States)

    1995-12-01

    Sorbent Technologies Corporation, of the United States, is currently developing and demonstrating a new waste free, retrofitable, high-SO{sub 2} removal duct-injection process. Up to 85 percent SO{sub 2} removal is achieved by simply injecting a new dry lime-based sorbent into the flue-gas duct, collecting the sorbent downstream in a particulate collector, and then recycling the sorbent. By avoiding large, expensive components, the process can have low capital costs, making it especially appropriate for smaller, older, less-utilized plants. The key to the new technology is the use of sorbent supports. Supported sorbents are produced by coating hydrated lime onto inexpensive mineral supports, such as exfoliated vermiculite or perlite. Consequently, there are no liquid, sludge, or solid wastes with the new technology. Once saturated with SO{sub 2}, the spent sorbent can be easily pelletized into a valuable soil-conditioning agricultural by-product, for the sustainable development that the future requires. This paper describes Sorbent Technologies` pilot demonstration of supported sorbent injection at the Ohio Edison Company`s R.E. Burger station. The Burger effort is also the first demonstration of the Electric Power Research Institute`s new {open_quotes}COHPAC{close_quotes} baghouse technology in a sorbent-injection desulfurization application.

  4. Ducted combustion chamber for direct injection engines and method

    Science.gov (United States)

    Mueller, Charles

    2015-03-03

    An internal combustion engine includes an engine block having a cylinder bore and a cylinder head having a flame deck surface disposed at one end of the cylinder bore. A piston connected to a rotatable crankshaft and configured to reciprocate within the cylinder bore has a piston crown portion facing the flame deck surface such that a combustion chamber is defined within the cylinder bore and between the piston crown and the flame deck surface. A fuel injector having a nozzle tip disposed in fluid communication with the combustion chamber has at least one nozzle opening configured to inject a fuel jet into the combustion chamber along a fuel jet centerline. At least one duct defined in the combustion chamber between the piston crown and the flame deck surface has a generally rectangular cross section and extends in a radial direction relative to the cylinder bore substantially along the fuel jet centerline.

  5. Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 3, Task 3.2: Scale-up testing; Topical report No. 4, Task 3.3: Advanced configurations; Topical report No. 5, Task 3.4: Process controls; Topical report No. 6, Task 3.5: Failure modes; Task 3.6: Waste characterization, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Gooch, J.P.; Merritt, R.L. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G.; Hunt, J.E. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

    1992-08-01

    This document is the third interim report on tests that were conducted at the Duct Injection Test Facility (DITF) operated for the Department of Energy at Unit 5 of the Ohio Power Company`s Muskingum River station in Beverly, Ohio. At the DITF dry calcium hydroxide (Ca(OH)2), an aqueous slurry of Ca(OH){sub 2} (prepared by slaking quicklime), or a mixture of one of these sorbents with waste ash from earlier tests was injected into a slipstream of flue gas from the Unit 5 boiler to achieve partial removal of SO{sub 2} in the flue gas. Up to 50,000 acfm of flue gas was taken from the inlet to the Unit 5 electrostatic precipitator (ESP) for these tests. Water was injected separately with the dry sorbent or as part of the slurry to cool the flue gas and increase the water vapor content of the flue gas. The addition of water, either as a separate spray or in the slurry makes the reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state when it can physically wet the sorbent particles, and not especially effective in the vapor state. Higher values of calcium utilization were obtained with slurry injection than with dry sorbent injection and humidification. Slurries made from reagent slaked lime, mixtures of reagent slaked lime and recycle ash, and from recycle ash alone were injected through the same nozzles used for humidification. The focus of most of these tests was on the constant addition of recycle ash to reduce the amount of slaked lime required for SO{sub 2} removal (for best economics). Testing was continued until the amount of Ca(OH){sub 2} in the recycle ash equaled that predicted for equilibrium Two test cases were evaluated: a low Ca/S ratio (1.0 reagent, 44{degrees}/F approach) for 50% SO{sub 2} removal and a high Ca/S ratio (1.7 reagent, 24{degrees}F approach) for 88% SO{sub 2} removal.

  6. Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 3, Task 3. 2: Scale-up testing; Topical report No. 4, Task 3. 3: Advanced configurations; Topical report No. 5, Task 3. 4: Process controls; Topical report No. 6, Task 3. 5: Failure modes; Task 3. 6: Waste characterization, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Gooch, J.P.; Merritt, R.L. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G.; Hunt, J.E. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

    1992-08-01

    This document is the third interim report on tests that were conducted at the Duct Injection Test Facility (DITF) operated for the Department of Energy at Unit 5 of the Ohio Power Company's Muskingum River station in Beverly, Ohio. At the DITF dry calcium hydroxide (Ca(OH)2), an aqueous slurry of Ca(OH)[sub 2] (prepared by slaking quicklime), or a mixture of one of these sorbents with waste ash from earlier tests was injected into a slipstream of flue gas from the Unit 5 boiler to achieve partial removal of SO[sub 2] in the flue gas. Up to 50,000 acfm of flue gas was taken from the inlet to the Unit 5 electrostatic precipitator (ESP) for these tests. Water was injected separately with the dry sorbent or as part of the slurry to cool the flue gas and increase the water vapor content of the flue gas. The addition of water, either as a separate spray or in the slurry makes the reaction between the sorbent and the SO[sub 2] more complete; the presumption is that water is effective in the liquid state when it can physically wet the sorbent particles, and not especially effective in the vapor state. Higher values of calcium utilization were obtained with slurry injection than with dry sorbent injection and humidification. Slurries made from reagent slaked lime, mixtures of reagent slaked lime and recycle ash, and from recycle ash alone were injected through the same nozzles used for humidification. The focus of most of these tests was on the constant addition of recycle ash to reduce the amount of slaked lime required for SO[sub 2] removal (for best economics). Testing was continued until the amount of Ca(OH)[sub 2] in the recycle ash equaled that predicted for equilibrium Two test cases were evaluated: a low Ca/S ratio (1.0 reagent, 44[degrees]/F approach) for 50% SO[sub 2] removal and a high Ca/S ratio (1.7 reagent, 24[degrees]F approach) for 88% SO[sub 2] removal.

  7. A model for dry sodium bicarbonate duct injection flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Changfa Wu; Soon-Jai Khang; Tim C. Keener; Sang-Kwun Lee [University of Cincinnati, Cincinnati, OH (United States). Department of Chemical Engineering

    2004-03-01

    A mathematical model is developed for simulation of dry sodium bicarbonate (NaHCO{sub 3}) duct injection for the removal of sulfur dioxide (SO{sub 2}) in flue gases across a fabric filter (baghouse). The model employs parallel reaction kinetics and assumes that the sodium bicarbonate injection process can be separated into two stages. The first stage is a transport duct section where NaHCO{sub 3} particles are injected into the sulfur dioxide laden gas stream. The second stage is the fabric filter section where sodium sorbents are collected and behave as a variable depth fixed bed reactor. The process simulation for the efficiency of desulfurization in flue gas is performed and evaluated for a variety of operating conditions. It is found that the removal of SO{sub 2} within the duct section is small and negligible for most practical conditions, with a contribution normally less than 5% of total SO{sub 2} removal. The major removal of SO{sub 2} occurs across the filter cake, which accumulates the sorbent particles on the fabric filter. These particles are periodically disposed as the filter is cleaned. The major factors for the process are temperature, particle size and SO{sub 2} gas concentration for all operating conditions. At low temperatures, the removal of SO{sub 2} increases as temperature increases, but the removal decreases at higher temperatures due to the impact of the thermal decomposition reaction of NaHCO{sub 3} on SO{sub 2} removal. It was found that the temperature for the highest removal of SO{sub 2} is within the range of 127-150{sup o}C and the removal efficiency also depends on particle size.

  8. Field Test of Advanced Duct-Sealing Technologies Within the Weatherization Assistance Program

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, MP

    2001-12-05

    A field test of an aerosol-spray duct-sealing technology and a conventional, best-practice approach was performed in 80 homes to determine the efficacy and programmatic needs of the duct-sealing technologies as applied in the U.S. Department of Energy Weatherization Assistance Program. The field test was performed in five states: Iowa, Virginia, Washington, West Virginia, and Wyoming. The study found that, compared with the best-practice approach, the aerosol-spray technology is 50% more effective at sealing duct leaks and can potentially reduce labor time and costs for duct sealing by 70%, or almost 4 crew-hours. Further study to encourage and promote use of the aerosol-spray technology within the Weatherization Assistance Program is recommended. A pilot test of full production weatherization programs using the aerosol-spray technology is recommended to develop approaches for integrating this technology with other energy conservation measures and minimizing impacts on weatherization agency logistics. In order to allow or improve adoption of the aerosol spray technology within the Weatherization Assistance Program, issues must be addressed concerning equipment costs, use of the technology under franchise arrangements with Aeroseal, Inc. (the holders of an exclusive license to use this technology), software used to control the equipment, safety, and training. Application testing of the aerosol-spray technology in mobile homes is also recommended.

  9. Sodium bicarbonate in-duct injection with sodium sulfate recovery for SO2/NOx control

    International Nuclear Information System (INIS)

    Bennett, R.; Darmstaedter, E.

    1991-01-01

    Dry sodium injection with sodium bicarbonate has been used commercially at industrial sites since the mid 1980's. In the past three years, five full scale commercial demonstrations have been completed on electric utility coal fired units. Up to 75% SO 2 removal with 0-40% NO x removal has been achieved on units equipped with ESPs. Recent slip stream studies have proven up to 90% SO 2 removal and 25% NO x removal when injection is ahead of a baghouse. If dry sodium bicarbonate sorbent injection technology is used prior to a retrofitted baghouse, but after an existing ESP the sodium sulfate by-product/flyash mixture in the baghouse is over 90% Na 2 SO 4 . Simple filtration and crystallization will yield a high value 99% + pure Na 2 SO 4 for sale. In this application, no liquid discharge occurs and potentially no solids discharge, since flyash recovered from the filter is either recycled to the boiler with the coal stream or reinjected into the boiler. EPA IAPCS model Version 4 is modified to project costs for this SO 2 /NO x removal technology when couples with Na 2 SO 4 recovery. In this paper an example is used to show hardware requirements, consumables accountability, by-product recovery rates, capital costs and levelized costs

  10. Laminar flow in porous pipes and ducts with variable suction or injection at the wall

    International Nuclear Information System (INIS)

    Souza Araujo, P.M. de; Stuckenbruck, S.

    1977-01-01

    The laminar flow of an incompressible fluid is analysed along a porous-walled straight circular tube and a flat duct formed by parallel porous plates. The non-similarity of velocity profiles is verified and the analytical solution is obtained by expanding the axial velocity component in a power series. The mass flow through the walls is taken into consideration as an application of Darcy's Law. Adverse axial pressure gradients and occasional reverse flow near the wall are pointed out in the work. (Author) [pt

  11. Development of Adaptive Acoustic Impedance Control Technologies of Acoustic Duct Liner

    Directory of Open Access Journals (Sweden)

    Hiroshi Kobayashi

    2011-01-01

    Full Text Available This paper describes the development of adaptive acoustic impedance control (AAC technologies to achieve a larger fan noise reduction, by adaptively adjusting reactance and resistance of the acoustic liner impedance. For the actual proof of the AAC technology III performance, the advanced fan noise absorption control duct liner II was made on trial basis, with the simple control system and the plain device. And, then, the duct liner II was examined for the AAC technology I, II, and III models, using the high speed fan test facility. The test results made clear that the duct liner II of the AAC technology III model could achieve the fan noise reduction higher than O.A. SPL 10 dB (A at the maximum fan speed 6000 rpm, containing the reduction of fundamental BPF tone of 18 dB and 2nd BPF tone of 10 dB in response to the fan peed change from 3000 to 6000 rpm.

  12. Neogenesis and proliferation of β-cells induced by human betacellulin gene transduction via retrograde pancreatic duct injection of an adenovirus vector

    International Nuclear Information System (INIS)

    Tokui, Yae; Kozawa, Junji; Yamagata, Kazuya; Zhang, Jun; Ohmoto, Hiroshi; Tochino, Yoshihiro; Okita, Kohei; Iwahashi, Hiromi; Namba, Mitsuyoshi; Shimomura, Iichiro; Miyagawa, Jun-ichiro

    2006-01-01

    Betacellulin (BTC) has been shown to have a role in the differentiation and proliferation of β-cells both in vitro and in vivo. We administered a human betacellulin (hBTC) adenovirus vector to male ICR mice via retrograde pancreatic duct injection. As a control, we administered a β-galactosidase adenovirus vector. In the mice, hBTC protein was mainly overexpressed by pancreatic duct cells. On immunohistochemical analysis, we observed features of β-cell neogenesis as newly formed insulin-positive cells in the duct cell lining or islet-like cell clusters (ICCs) closely associated with the ducts. The BrdU labeling index of β-cells was also increased by the betacellulin vector compared with that of control mice. These results indicate that hBTC gene transduction into adult pancreatic duct cells promoted β-cell differentiation (mainly from duct cells) and proliferation of pre-existing β-cells, resulting in an increase of the β-cell mass that improved glucose tolerance in diabetic mice

  13. INJECTION TECHNOLOGY RESEARCH OF THE PROTECTIVE SCREEN

    Directory of Open Access Journals (Sweden)

    MENEJLYUK A. I.

    2016-12-01

    Full Text Available Formulation of the problem. This article contains information about the methods and the planning principles used in experimental research study of the injection technology of impervious screen. Today, there are ways to create impervious screens and curtains solve soil protection issues in the field impermeable layer arrangement at a shallow depth. However, for Ukraine, in the burial sites of radiation and other wastes is urgent issue of protection of underground space in places with deep impermeable layer. Classical methods can not fully solve such problems. To solve them, you need to develop innovative technology to create such a screen, which will lie authentic sole object to be protected, at the project depth. For the experiments, it is necessary to choose the most important indicator, and technological factors affecting it. This is due to the fact that the proposed technology provides for lesser known technical solutions, the use of which should ultimately result in impervious screens with desired properties. Goal. The aim of this study is the selection of technological parameters of injection, design of experiments and the selection of indicators characterizing the efficient operation of the screen. Such constructs must first have almost zero permeability. In this paper, it was of interest to study the influence of process parameters on the filtration rate of the protective screen. Conclusion. As a result of the design of experiments, the basic technological factors that have a significant effect on the studied parameters. varying levels of these factors are also identified, which in turn makes it possible to determine the optimum process parameters creating a screen that meets all the desired properties and characteristics. Based on a series of experiments it is possible to obtain optimal formulations for different types of soils.

  14. Alternative Approach to Traumatic Stensen’s Duct Injuries Accompanied by Glandular Involvement: Botulinum Toxin Injection to the Gland in Conjunction with Microsurgical Repair of the Duct in an Acute Setting

    Directory of Open Access Journals (Sweden)

    Mert Çalış

    2017-12-01

    Full Text Available Objective: The aim of this study was to evaluate the long-term results of a simultaneous application of botulinum toxin to the parotid gland in conjunction with the microsurgical repair of the duct in an acute setting and to encourage using botulinum toxin as a first-line option to prevent future complications associated with glandular involvement. Material and Methods: Three patients who were referred to the Plastic Surgery Clinic by the emergency room of the Hacettepe University Hospital after maxillofacial trauma are reviewed in this study. Exploration of the facial nerve and Stensen’s duct was planned for all patients within the first 72 hours after their injuries. After intraoral catheterization of the Stensen’s duct through the papilla using an epidural catheter, microsurgical end-to-end anastomosis was performed. Concurrently, 100 units of botulinum toxin A was injected at standardized eight points to the parotid gland. Results: Postoperative magnetic resonance (MR sialography revealed patency in all patients at the end of postoperative first year. The mean postoperative parotid volume of the injured and non-injured sides were 19.82±10.55 cm3 and 17.79±10.98 cm3, respectively, and the results were found to be comparable. Fibrillation potentials in the postoperative electromyography recordings and clinical examination demonstrated nerve regeneration. Conclusion: Botulinum toxin A appears to be effective in treating duct injuries accompanied by glandular involvement in an acute setting, as well as in preventing long-term complications.

  15. Bibliography: injection technology applicable to geothermal utilization

    Energy Technology Data Exchange (ETDEWEB)

    Darnell, A.J.; Eichelberger, R.L.

    1982-03-19

    This bibliography cites 500 documents that may be helpful in planning, analysis, research, and development of the various aspects of injection technology in geothermal applications. These documents include results from government research; development, demonstration, and commercialization programs; selected references from the literature; symposia; references from various technical societies and installations; reference books; reviews; and other selected material. The cited references are from (1) subject searching, using indexing, storage, and retrieval information data base of the Department of Energy's Technical Information Center's on-line retrieval system, RECON; (2) searches of references from the RECON data base, of work by authors known to be active in the field of geothermal energy research and development; (3) subject and author searches by the computerized data storage and retrieval system of Chemical Abstracts, American Chemical Society, Washington, DC; and (4) selected references from texts and reviews on this subject. Each citation includes title, author, author affiliation, date of publication, and source. The citations are listed in chronological order (most recent first) in each of the subject categories for which this search was made. The RECON accession number is also given.

  16. Accelerator Technology: Injection and Extraction Related Hardware: Kickers and Septa

    CERN Document Server

    Barnes, M J; Mertens, V

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the the Section '8.7 Injection and Extraction Related Hardware: Kickers and Septa' of the Chapter '8 Accelerator Technology' with the content: 8.7 Injection and Extraction Related Hardware: Kickers and Septa 8.7.1 Fast Pulsed Systems (Kickers) 8.7.2 Electrostatic and Magnetic Septa

  17. Enhancement of melting heat transfer of ice slurries by an injection flow in a rectangular cross sectional horizontal duct

    International Nuclear Information System (INIS)

    Fujii, Kota; Yamada, Masahiko

    2013-01-01

    Ice slurries are now commonly used as cold thermal storage materials, and have the potential to be applied to other engineering fields such as quenching metals to control properties, emergency cooling systems, and preservation of food and biomaterials at low temperatures. Although ice slurries have been widely utilized because of their high thermal storage densities, previous studies have revealed that the latent heat of ice particles is not completely released on melting because of insufficient contact between the ice particles and a heated surface. In this study, an injection flow that was bifurcated from the main flow of an ice slurry was employed to promote melting heat transfer of ice particles on a horizontal heated surface. The effects of injection angle and injection flow rate on local heat transfer coefficients and heat transfer coefficient ratios were determined experimentally. The results show that from two to three times higher heat transfer coefficients can be obtained by using large injection flow rates and injection angles. However, low injection angles improved the utilization rate of the latent heat of ice near the injection point by approximately a factor of two compared to that without injection. -- Highlights: • Melting of ice slurries were enhanced by the injection under constant total flow rate. • Contribution of ice particles and their latent heat to heat transfer was investigated. • Effect of velocity ratio of injection to that of main flow was examined. • Effect of the angle of injection flow to the main flow was also examined. • Appropriate conditions for the use of latent heat of ice and heat transfer did not coincide

  18. [Impurity removal technology of Tongan injection in liquid preparation process].

    Science.gov (United States)

    Yang, Xu-fang; Wang, Xiu-hai; Bai, Wei-rong; Kang, Xiao-dong; Liu, Jun-chao; Wu, Yun; Xiao, Wei

    2015-08-01

    In order to effectively remove the invalid impurities in Tongan injection, optimize the optimal parameters of the impurity removal technology of liquid mixing process, in this paper, taking Tongan injection as the research object, with the contents of celandine alkali, and sinomenine, solids reduction efficiency, and related substances inspection as the evaluation indexes, the removal of impurities and related substances by the combined process of refrigeration, coction and activated carbon adsorption were investigated, the feasibility of the impurity removal method was definited and the process parameters were optimized. The optimized process parameters were as follows: refrigerated for 36 h, boiled for 15 min, activated carbon dosage of 0.3%, temperature 100 degrees C, adsorption time 10 min. It can effectively remove the tannin, and other impurities, thus ensure the quality and safety of products.

  19. Injection technologies for the repair of damaged concrete structures

    CERN Document Server

    Panasyuk, V V; Sylovanyuk, V P

    2014-01-01

    This book analyzes the most important achievements in science and engineering practice concerning operational factors that cause damage to concrete and reinforced concrete structures. It includes methods for assessing their strength and service life, especially those that are based on modern concepts of the fracture mechanics of materials. It also includes basic approaches to the prediction of the remaining service life for long-term operational structures. Much attention is paid to injection technologies for restoring the serviceability of damaged concrete and reinforced concrete structures. In particular, technologies for remedying holes, cracks, corrosion damages etc. The books contains sample cases in which the above technologies have been used to restore structural integrity and extend the reliable service life of concrete and reinforced concrete constructions, especially NPPs, underground railways, bridges, seaports and historical relics.

  20. The research of new type stratified water injection process intelligent measurement technology

    Science.gov (United States)

    Zhao, Xin

    2017-10-01

    To meet the needs of injection and development of Daqing Oilfield, the injection of oil from the early stage of general water injection to the subdivision of water is the purpose of improving the utilization degree and the qualified rate of water injection, improving the performance of water injection column and the matching process. Sets of suitable for high water content of the effective water injection technology supporting technology. New layered water injection technology intelligent measurement technology will be more information testing and flow control combined into a unified whole, long-term automatic monitoring of the work of the various sections, in the custom The process has the characteristics of "multi-layer synchronous measurement, continuous monitoring of process parameters, centralized admission data", which can meet the requirement of subdivision water injection, but also realize the automatic synchronization measurement of each interval, greatly improve the efficiency of tiered injection wells to provide a new means for the remaining oil potential.

  1. Alternative Approach to Traumatic Stensen’s Duct Injuries Accompanied by Glandular Involvement: Botulinum Toxin Injection to the Gland in Conjunction with Microsurgical Repair of the Duct in an Acute Setting

    OpenAIRE

    Mert Çalış; Zeynep Öz; Hakan Uzun; Burçe Özgen; Alp Çetin3; Ali Emre Aksu

    2017-01-01

    Objective: The aim of this study was to evaluate the long-term results of a simultaneous application of botulinum toxin to the parotid gland in conjunction with the microsurgical repair of the duct in an acute setting and to encourage using botulinum toxin as a first-line option to prevent future complications associated with glandular involvement. Material and Methods: Three patients who were referred to the Plastic Surgery Clinic by the emergency room of the Hacettepe University Hospita...

  2. Bile Duct Exploration

    Science.gov (United States)

    ... Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Bile Duct Exploration Common bile duct exploration is a ... Test Details Results and Follow-Up What is bile, and what is bile duct exploration? Bile is ...

  3. Visualization of the thoracic duct by lymphoscintigraphy

    International Nuclear Information System (INIS)

    Baulieu, F.; Baulieu, J.L.; Itti, R.; Tours Univ., 37

    1987-01-01

    Imaging of the thoracic duct is usually performed by radiological lymphography. However, this procedure, which uses an oil based dye injected directly into the lymph channels, has some adverse effects. In this paper we note that lymphoscintigraphy, a physiological and non invasive method, may visualize thoracic duct abnormalities, and might be particularly usefull when radiological lymphography is contraindicated. (orig.)

  4. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    International Nuclear Information System (INIS)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct

  5. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    Science.gov (United States)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  6. Bile Duct Cancer (Cholangiocarcinoma)

    Science.gov (United States)

    ... Home > Types of Cancer > Bile Duct Cancer (Cholangiocarcinoma) Bile Duct Cancer (Cholangiocarcinoma) This is Cancer.Net’s Guide to Bile Duct Cancer (Cholangiocarcinoma). Use the menu below to ...

  7. Demonstration of pharmaceutical tablet coating process by injection molding technology.

    Science.gov (United States)

    Puri, Vibha; Brancazio, David; Harinath, Eranda; Martinez, Alexander R; Desai, Parind M; Jensen, Keith D; Chun, Jung-Hoon; Braatz, Richard D; Myerson, Allan S; Trout, Bernhardt L

    2018-01-15

    We demonstrate the coating of tablets using an injection molding (IM) process that has advantage of being solvent free and can provide precision coat features. The selected core tablets comprising 10% w/w griseofulvin were prepared by an integrated hot melt extrusion-injection molding (HME-IM) process. Coating trials were conducted on a vertical injection mold machine. Polyethylene glycol and polyethylene oxide based hot melt extruded coat compositions were used. Tablet coating process feasibility was successfully demonstrated using different coating mold designs (with both overlapping and non-overlapping coatings at the weld) and coat thicknesses of 150 and 300 μm. The resultant coated tablets had acceptable appearance, seal at the weld, and immediate drug release profile (with an acceptable lag time). Since IM is a continuous process, this study opens opportunities to develop HME-IM continuous processes for transforming powder to coated tablets. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Two Crosslinking Technologies for Superficial Reticular Dermis Injection: A Comparative Ultrasound and Histologic Study

    OpenAIRE

    Micheels, Patrick; Besse, Stéphanie; Sarazin, Didier

    2017-01-01

    Background: Few hyaluronic acid fillers have been developed for superficial injection. Objective: To compare the diffusion and integration properties of cohesive polydensified matrix and Vycross® technology hyaluronic acid fillers with lidocaine following injection into the superficial reticular dermis. Methods and materials: Two subjects received two injections each of cohesive polydensified matrix and Vycross® hyaluronic acid (0.2mL/site) in the superficial reticular dermis of the buttock u...

  9. Direct Injection Compression Ignition Diesel Automotive Technology Education GATE Program

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Carl L

    2006-09-25

    The underlying goal of this prqject was to provide multi-disciplinary engineering training for graduate students in the area of internal combustion engines, specifically in direct injection compression ignition engines. The program was designed to educate highly qualified engineers and scientists that will seek to overcome teclmological barriers preventing the development and production of cost-effective high-efficiency vehicles for the U.S. market. Fu1iher, these highly qualified engineers and scientists will foster an educational process to train a future workforce of automotive engineering professionals who are knowledgeable about and have experience in developing and commercializing critical advanced automotive teclmologies. Eight objectives were defmed to accomplish this goal: 1. Develop an interdisciplinary internal co1nbustion engine curriculum emphasizing direct injected combustion ignited diesel engines. 2. Encourage and promote interdisciplinary interaction of the faculty. 3. Offer a Ph.D. degree in internal combustion engines based upon an interdisciplinary cuniculum. 4. Promote strong interaction with indusuy, develop a sense of responsibility with industry and pursue a self sustaining program. 5. Establish collaborative arrangements and network universities active in internal combustion engine study. 6. Further Enhance a First Class educational facility. 7. Establish 'off-campus' M.S. and Ph.D. engine programs of study at various indusuial sites. 8. Extend and Enhance the Graduate Experience.

  10. DEMONSTRATION OF SORBENT INJECTION TECHNOLOGY ON A WALL-FIRED UTILITY BOILER (EDGEWATER LIMB DEMONSTRATION)

    Science.gov (United States)

    The report gives results of the full-scale demonstration of Limestone Injection Multistage Burner (LIMB) technology on the coal-fired, 105 MW, Unit 4 boiler at Ohio Edison's Edgewater Station. eveloped as a technology aimed at moderate levels of sulfur dioxide (SO2) and nitrogen ...

  11. STUDY OF HORIZONTAL SCREEN STRENGTH CREATED BY INJECTION TECHNOLOGY CEMENT BINDER BASED

    Directory of Open Access Journals (Sweden)

    BORISOV A. A.

    2016-09-01

    Full Text Available Annotation. Formulation of the problem. An important indicator in the planning of injection works is a particle size distribution of the soil and the very composition of injection. The ideal case is to comply with the injection optimum ratio between the size of particles in solution and injectable medium. This ratio corresponds to complete impregnation of the environment. Today in the field of building technologies known classical methods of grouting with the injection process [9]. This may be a cementation or silicification with different chemical compositions. Due to the fact that we have proposed an innovative technology of impervious curtain device, special attention should be paid to the performance and physical and mechanical properties of the resulting soil-injection. This is due to the fact that the proposed technology provides for lesser known technical solutions, the use of which should ultimately result in impervious screens with desired properties. Goal. The aim of this study is to investigate the properties of the resulting soil-concrete impervious screen. Such structures should have defined a number of physical and mechanical properties. In this paper, it was of interest to study the compressive strength of the resulting soil-concrete structure. Conclusion. As a result of experimentation and implementation of complex obtained experimentally-statistical models that describe the main soil-quality indicators. Based on these data is possible optimal selection of formulation and technological structure for sandy soils with different modules size of its particles.

  12. Injection moulding and selective metallisation technologies for polymer Microsystems

    DEFF Research Database (Denmark)

    Tenchine, L.; Gout, S.; Dessors, S.

    2016-01-01

    The present paper describes how developing and optimizing high-throughput integrated technologies for theproduction of miniaturised multi-material and multi-functional components at industrial scale. Based on 2 industrialdemonstrators (a band diplexer and a micro aeraulic device), the paper shows...

  13. Modern technologies of local injection anesthesia in dental practice

    Directory of Open Access Journals (Sweden)

    Sohov S.Т.

    2013-09-01

    Full Text Available Objective: To assess the importance of using the new system Quick Sleeper for local anesthesia, to highlight benefits of quick and comfortable anesthesia. Material and Methods. The examination of effectiveness, convenience of this kind of anesthesia has been carried out. Results. All patients, taking part in this examination, confirmed more comfortable condition after this anesthesia than conductor and infiltration methods of anesthesia. The effect of anesthesia is better than after conductor anesthesia. Conclusion. This technology guarantees equal introduction and spread of anesthetic, independently of tissue density, eliminating the risk of carpule breakage.

  14. Bile duct stricture

    Science.gov (United States)

    ... duct, the tube that moves bile from the liver to the small intestine. Bile is a substance that helps with digestion. ... causes of this condition include: Cancer of the bile duct, liver or pancreas Damage and scarring due to a ...

  15. Review of hydrogen pellet injection technology for plasma fueling applications

    International Nuclear Information System (INIS)

    Milora, S.L.

    1989-01-01

    In the past several years, steady progress has been made worldwide in the development of high-speed hydrogen pellet injectors for fueling magnetically confined plasmas. Several fueling systems based on the conventional pneumatic and centrifuge acceleration concepts have been put into practice on a wide variety of toroidal plasma confinement devices. Long-pulse fueling has been demonstrated in the parameter range 0.8--1.3 km/s, for pellets up to 6 mm in diameter, and at delivery rates up to 40 Hz. Conventional systems have demonstrated the technology to speeds approaching 2 km/s, and several more exotic accelerator concepts are under development to meet the more demanding requirements of the next generation of reactor-grade plasmas. These include a gas gun that can operate in tritium, the two-stage light gas gun, electrothermal guns, electromagnetic rail guns, and an electron-beam-driven thruster. Although these devices are in various stages of development, velocities of 3.8 km/s have already been achieved with two-stage light gas guns, and the prospects for attaining 5 km/s in the near future appear good

  16. JET neutral beam duct Optical Interlock

    Energy Technology Data Exchange (ETDEWEB)

    Ash, A.D.; Jones, T.T.C.; Surrey, E.; Ćirić, D.; Hall, S.I.; Young, D.; Afzal, M.; Hackett, L.; Day, I.E.; King, R.

    2015-10-15

    Highlights: • Optical Interlocks were installed on the JET NBI system as part of the EP2 upgrade. • The system protects the JET tokamak and NBI systems from thermal load damage. • Balmer-α beam emission is used to monitor the neutral beam-line pressure. • We demonstrate an improved trip delay of 2 ms compared to 50 ms before EP2. - Abstract: The JET Neutral Beam Injection (NBI) system is the most powerful neutral beam plasma heating system currently operating. Optical Interlocks were installed on the beam lines in 2011 for the JET Enhancement Project 2 (EP2), when the heating power was increased from 23 MW to 34 MW. JET NBI has two beam lines. Each has eight positive ion injectors operating in deuterium at 80 kV–125 kV (accelerator voltage) and up to 65 A (beam current). Heating power is delivered through two ducts where the central power density can be more than 100 MW/m{sup 2}. In order to deliver this safely, the beam line pressure should be below 2 × 10{sup −5} mbar otherwise the power load on the duct from the re-ionised fraction of the beam is excessive. The new Optical Interlock monitors the duct pressure by measuring the Balmer-α beam emission (656 nm). This is proportional to the instantaneous beam flux and the duct pressure. Light is collected from a diagnostic window and focused into 1-mm diameter fibres. The Doppler shifted signal is selected using an angle-tuned interference filter. The light is measured by a photo-multiplier module with a logarithmic amplifier. The interlock activation time of 2 ms is sufficient to protect the system from a fully re-ionised beam—a significant improvement on the previous interlock. The dynamic range is sufficient to see bremsstrahlung emission from JET plasma and not saturate during plasma disruptions. For high neutron flux operations the optical fibres within the biological shield can be annealed to 350 °C. A self-test is possible by illuminating the diagnostic window with a test lamp and measuring

  17. DEMONSTRATION OF SORBENT INJECTION TECHNOLOGY ON A TANGENTIALLY COAL-FIRED UTILITY BOILER (YORKTOWN LIMB DEMONSTRATION)

    Science.gov (United States)

    The report summarizes activities conducted and results achieved in an EPA-sponsored program to demonstrate Limestone Injection Multistage Burner (LIMB) technology on a tangentially fired coal-burning utility boiler, Virginia Power's 180-MWe Yorktown Unit No. 2. his successfully d...

  18. TEST DESIGN FOR ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF ADD-ON NOX CONTROL UTILIZING OZONE INJECTION

    Science.gov (United States)

    The paper discusses the test design for environmental technology verification (ETV) of add-0n nitrogen oxides (NOx) control utilizing ozone injection. (NOTE: ETV is an EPA-established program to enhance domestic and international market acceptance of new or improved commercially...

  19. A wide variety of injection molding technologies is now applicable to small series and mass production

    International Nuclear Information System (INIS)

    Bloß, P.; Jüttner, G.; Jacob, S.; Löser, C.; Michaelis, J.; Krajewsky, P.

    2014-01-01

    Micro plastic parts open new fields for application, e. g., to electronics, sensor technologies, optics, and medical engineering. Before micro parts can go to mass production, there is a strong need of having the possibility for testing different designs and materials including material combinations. Hence, flexible individual technical and technological solutions for processing are necessary. To manufacture high quality micro parts, a micro injection moulding machine named formicaPlast based on a two-step plunger injection technology was developed. Resulting from its design, the residence time and the accuracy problems for managing small shot volumes with reproducible high accuracy are uncompromisingly solved. Due to their simple geometry possessing smooth transitions and non adherent inner surfaces, the plunger units allow to process 'all' thermoplastics from polyolefines to high performance polymers, optical clear polymers, thermally sensitive bioresorbables, highly filled systems (the so-called powder injection molding PIM), and liquid silicon rubber (LSR, here with a special kit). The applied platform strategy in the 1K and 2K version allows integrating automation for assembling, handling and packaging. A perpendicular arrangement allows encapsulation of inserts, also partially, and integration of this machine into process chains. Considering a wide variety of different parts consisting of different materials, the high potential of the technology is demonstrated. Based on challenging industrial parts from electronic applications (2K micro MID and bump mat, where both are highly structured parts), the technological solutions are presented in more detail

  20. Evaluation by nanoindentation of technological products manufactured by pulse injection molding process

    Directory of Open Access Journals (Sweden)

    Natova Margarita

    2018-01-01

    Full Text Available During conventional polymer injection molding, flow- and weld lines can arise at the molded parts caused by disturbed polymer melt flow when it crosses different parts of the equipment. Such processed plastic goods have discrete zones of inhomogeneities of very small dimensions. In order to stabilize the melt flow and to equalize dimensions of such defective products, an approach for pulse injection molding is applied during production of polymer packagings. Testing methods used for evaluation of macromechanical performance of processed polymer products are not readily applicable to estimate the changes in visual surface obtained during pulse injecting. To overcome this testing inconvenience the performance of processed packagings is evaluated by nanoindentation. Using this method, a quantitative assessment of the polymer properties is obtained from different parts of technological products.

  1. Study on the integration of layered water injection technology and subdivision adjustment

    Science.gov (United States)

    Zhang, Yancui

    2018-06-01

    With oil many infillings, thin and poor reservoir exploitation changes gradually to low permeability, thin and poor reservoir development characteristics of multiple layers thickness, low permeability, in the actual development process, the General Department of oil layers of encryption perforation long thin and poor mining, interlayer contradiction more prominent, by conventional layered water injection that can alleviate the contradiction between layers to a certain extent, by the injection interval and other factors can not fundamentally solve the problem, leading to the potential well area key strata or layers is difficult to determine, the layering test and slicing technology is difficult to adapt to the need of tap water control block. This paper through numerical simulation using the conceptual model and the actual block, it has a great influence on the low permeability reservoir of different stratified water permeability combination of permeability technology and application limits, profit and loss balance principle, low oil prices on the lower series of subdivision technical and economic limit, so the reservoir subdivision reorganization, narrow wells mining, reduce the interference between layers, from the maximum fundamental improvement of layered water injection efficiency. At the same time, in order to meet the needs of reservoir subdivision adjustment, subdividing distance with water, a small interlayer wells subdivision technology for further research in the pickup, solved using two ordinary bridge eccentric water regulator with injection of two layers, by throwing exercise distance limit card from the larger problem, the water distribution card size from 7.0m to 1.0m, and the testing efficiency is improved, and provide technical support for further subdivision water injection wells.

  2. Blocked Tear Duct

    Science.gov (United States)

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  3. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is

  4. MRI ductography of contrast agent distribution and leakage in normal mouse mammary ducts and ducts with in situ cancer.

    Science.gov (United States)

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S

    2017-07-01

    High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (pcontrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Characterization of flow in a scroll duct

    Science.gov (United States)

    Begg, E. K.; Bennett, J. C.

    1985-01-01

    A quantitative, flow visualization study was made of a partially elliptic cross section, inward curving duct (scroll duct), with an axial outflow through a vaneless annular cutlet. The working fluid was water, with a Re(d) of 40,000 at the inlet to the scroll duct, this Reynolds number being representative of the conditions in an actual gas turbine scroll. Both still and high speed moving pictures of fluorescein dye injected into the flow and illuminated by an argon ion laser were used to document the flow. Strong secondary flow, similar to the secondary flow in a pipe bend, was found in the bottom half of the scroll within the first 180 degs of turning. The pressure field set up by the turning duct was strong enough to affect the inlet flow condition. At 90 degs downstream, the large scale secondary flow was found to be oscillatory in nature. The exit flow was nonuniform in the annular exit. By 270 degs downstream, the flow appeared unorganized with no distinctive secondary flow pattern. Large scale structures from the upstream core region appeared by 90 degs and continued through the duct to reenter at the inlet section.

  6. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  7. Bile duct obstruction

    Science.gov (United States)

    ... Tumors that have spread to the biliary system Liver and bile duct worms (flukes) The risk factors include: History of ... Increased bilirubin level Increased alkaline phosphatase level Increased liver enzymes The ... CT scan Endoscopic retrograde cholangiopancreatography ( ...

  8. Positive predictive value of cholescintigraphy in common bile duct obstruction

    International Nuclear Information System (INIS)

    Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.; Growcock, G.W.

    1986-01-01

    Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presence of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct

  9. Tablet coating by injection molding technology - Optimization of coating formulation attributes and coating process parameters.

    Science.gov (United States)

    Desai, Parind M; Puri, Vibha; Brancazio, David; Halkude, Bhakti S; Hartman, Jeremy E; Wahane, Aniket V; Martinez, Alexander R; Jensen, Keith D; Harinath, Eranda; Braatz, Richard D; Chun, Jung-Hoon; Trout, Bernhardt L

    2018-01-01

    We developed and evaluated a solvent-free injection molding (IM) coating technology that could be suitable for continuous manufacturing via incorporation with IM tableting. Coating formulations (coating polymers and plasticizers) were prepared using hot-melt extrusion and screened via stress-strain analysis employing a universal testing machine. Selected coating formulations were studied for their melt flow characteristics. Tablets were coated using a vertical injection molding unit. Process parameters like softening temperature, injection pressure, and cooling temperature played a very important role in IM coating processing. IM coating employing polyethylene oxide (PEO) based formulations required sufficient room humidity (>30% RH) to avoid immediate cracks, whereas other formulations were insensitive to the room humidity. Tested formulations based on Eudrajit E PO and Kollicoat IR had unsuitable mechanical properties. Three coating formulations based on hydroxypropyl pea starch, PEO 1,000,000 and Opadry had favorable mechanical (35% elongation, >95×10 4 J/m 3 toughness) and melt flow (>0.4g/min) characteristics, that rendered acceptable IM coats. These three formulations increased the dissolution time by 10, 15 and 35min, respectively (75% drug release), compared to the uncoated tablets (15min). Coated tablets stored in several environmental conditions remained stable to cracking for the evaluated 8-week time period. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Technological Innovations of Carbon Dioxide Injection in EAF-LF Steelmaking

    Science.gov (United States)

    Wei, Guangsheng; Zhu, Rong; Wu, Xuetao; Dong, Kai; Yang, Lingzhi; Liu, Runzao

    2018-06-01

    In this study, the recent innovations and improvements in carbon dioxide (CO2) injection technologies for electric arc furnace (EAF)-ladle furnace (LF) steelmaking processes have been reviewed. The utilization of CO2 in the EAF-LF steelmaking process resulted in improved efficiency, purity and environmental impact. For example, coherent jets with CO2 and O2 mixed injection can reduce the amount of iron loss and dust generation, and submerged O2 and powder injection with CO2 in an EAF can increase the production efficiency and improve the dephosphorization and denitrification characteristics. Additionally, bottom-blowing CO2 in an EAF can strengthen molten bath stirring and improve nitrogen removal, while bottom-blowing CO2 in a LF can increase the rate of desulfurization and improve the removal of inclusions. Based on these innovations, a prospective process for the cyclic utilization of CO2 in the EAF-LF steelmaking process is introduced that is effective in mitigating greenhouse gas emissions from the steelmaking shop.

  11. Technological Innovations of Carbon Dioxide Injection in EAF-LF Steelmaking

    Science.gov (United States)

    Wei, Guangsheng; Zhu, Rong; Wu, Xuetao; Dong, Kai; Yang, Lingzhi; Liu, Runzao

    2018-03-01

    In this study, the recent innovations and improvements in carbon dioxide (CO2) injection technologies for electric arc furnace (EAF)-ladle furnace (LF) steelmaking processes have been reviewed. The utilization of CO2 in the EAF-LF steelmaking process resulted in improved efficiency, purity and environmental impact. For example, coherent jets with CO2 and O2 mixed injection can reduce the amount of iron loss and dust generation, and submerged O2 and powder injection with CO2 in an EAF can increase the production efficiency and improve the dephosphorization and denitrification characteristics. Additionally, bottom-blowing CO2 in an EAF can strengthen molten bath stirring and improve nitrogen removal, while bottom-blowing CO2 in a LF can increase the rate of desulfurization and improve the removal of inclusions. Based on these innovations, a prospective process for the cyclic utilization of CO2 in the EAF-LF steelmaking process is introduced that is effective in mitigating greenhouse gas emissions from the steelmaking shop.

  12. Physicochemical characterization of particulate emissions from a compression ignition engine employing two injection technologies and three fuels.

    Science.gov (United States)

    Surawski, N C; Miljevic, B; Ayoko, G A; Roberts, B A; Elbagir, S; Fairfull-Smith, K E; Bottle, S E; Ristovski, Z D

    2011-07-01

    Alternative fuels and injection technologies are a necessary component of particulate emission reduction strategies for compression ignition engines. Consequently, this study undertakes a physicochemical characterization of diesel particulate matter (DPM) for engines equipped with alternative injection technologies (direct injection and common rail) and alternative fuels (ultra low sulfur diesel, a 20% biodiesel blend, and a synthetic diesel). Particle physical properties were addressed by measuring particle number size distributions, and particle chemical properties were addressed by measuring polycyclic aromatic hydrocarbons (PAHs) and reactive oxygen species (ROS). Particle volatility was determined by passing the polydisperse size distribution through a thermodenuder set to 300 °C. The results from this study, conducted over a four point test cycle, showed that both fuel type and injection technology have an impact on particle emissions, but injection technology was the more important factor. Significant particle number emission (54%-84%) reductions were achieved at half load operation (1% increase-43% decrease at full load) with the common rail injection system; however, the particles had a significantly higher PAH fraction (by a factor of 2 to 4) and ROS concentrations (by a factor of 6 to 16) both expressed on a test-cycle averaged basis. The results of this study have significant implications for the health effects of DPM emissions from both direct injection and common rail engines utilizing various alternative fuels.

  13. Factors associated with patterns of mobile technology use among persons who inject drugs.

    Science.gov (United States)

    Collins, Kelly M; Armenta, Richard F; Cuevas-Mota, Jazmine; Liu, Lin; Strathdee, Steffanie A; Garfein, Richard S

    2016-01-01

    New and innovative methods of delivering interventions are needed to further reduce risky behaviors and increase overall health among persons who inject drugs (PWID). Mobile health (mHealth) interventions have potential for reaching PWID; however, little is known about mobile technology use (MTU) in this population. In this study, the authors identify patterns of MTU and identified factors associated with MTU among a cohort of PWID. Data were collected through a longitudinal cohort study examining drug use, risk behaviors, and health status among PWID in San Diego, California. Latent class analysis (LCA) was used to define patterns of MTU (i.e., making voice calls, text messaging, and mobile Internet access). Multinomial logistic regression was then used to identify demographic characteristics, risk behaviors, and health indicators associated with mobile technology use class. In LCA, a 4-class solution fit the data best. Class 1 was defined by low MTU (22%, n = 100); class 2, by PWID who accessed the Internet using a mobile device but did not use voice or text messaging (20%, n = 95); class 3, by primarily voice, text, and connected Internet use (17%, n = 91); and class 4, by high MTU (41%, n = 175). Compared with low MTU, high MTU class members were more likely to be younger, have higher socioeconomic status, sell drugs, and inject methamphetamine daily. The majority of PWID in San Diego use mobile technology for voice, text, and/or Internet access, indicating that rapid uptake of mHealth interventions may be possible in this population. However, low ownership and use of mobile technology among older and/or homeless individuals will need to be considered when implementing mHealth interventions among PWID.

  14. Curved-Duct

    Directory of Open Access Journals (Sweden)

    Je Hyun Baekt

    2000-01-01

    Full Text Available A numerical study is conducted on the fully-developed laminar flow of an incompressible viscous fluid in a square duct rotating about a perpendicular axis to the axial direction of the duct. At the straight duct, the rotation produces vortices due to the Coriolis force. Generally two vortex cells are formed and the axial velocity distribution is distorted by the effect of this Coriolis force. When a convective force is weak, two counter-rotating vortices are shown with a quasi-parabolic axial velocity profile for weak rotation rates. As the rotation rate increases, the axial velocity on the vertical centreline of the duct begins to flatten and the location of vorticity center is moved near to wall by the effect of the Coriolis force. When the convective inertia force is strong, a double-vortex secondary flow appears in the transverse planes of the duct for weak rotation rates but as the speed of rotation increases the secondary flow is shown to split into an asymmetric configuration of four counter-rotating vortices. If the rotation rates are increased further, the secondary flow restabilizes to a slightly asymmetric double-vortex configuration. Also, a numerical study is conducted on the laminar flow of an incompressible viscous fluid in a 90°-bend square duct that rotates about axis parallel to the axial direction of the inlet. At a 90°-bend square duct, the feature of flow by the effect of a Coriolis force and a centrifugal force, namely a secondary flow by the centrifugal force in the curved region and the Coriolis force in the downstream region, is shown since the centrifugal force in curved region and the Coriolis force in downstream region are dominant respectively.

  15. Patent arterial duct

    Directory of Open Access Journals (Sweden)

    Martin Robin P

    2009-07-01

    Full Text Available Abstract Patent arterial duct (PAD is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes. Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of

  16. [Alcohol-purification technology and its particle sedimentation process in manufactory of Fufang Kushen injection].

    Science.gov (United States)

    Liu, Xiaoqian; Tong, Yan; Wang, Jinyu; Wang, Ruizhen; Zhang, Yanxia; Wang, Zhimin

    2011-11-01

    Fufang Kushen injection was selected as the model drug, to optimize its alcohol-purification process and understand the characteristics of particle sedimentation process, and to investigate the feasibility of using process analytical technology (PAT) on traditional Chinese medicine (TCM) manufacturing. Total alkaloids (calculated by matrine, oxymatrine, sophoridine and oxysophoridine) and macrozamin were selected as quality evaluation markers to optimize the process of Fufang Kushen injection purification with alcohol. Process parameters of particulate formed in the alcohol-purification, such as the number, density and sedimentation velocity, were also determined to define the sedimentation time and well understand the process. The purification process was optimized as that alcohol is added to the concentrated extract solution (drug material) to certain concentration for 2 times and deposited the alcohol-solution containing drug-material to sediment for some time, i.e. 60% alcohol deposited for 36 hours, filter and then 80% -90% alcohol deposited for 6 hours in turn. The content of total alkaloids was decreased a little during the depositing process. The average settling time of particles with the diameters of 10, 25 microm were 157.7, 25.2 h in the first alcohol-purified process, and 84.2, 13.5 h in the second alcohol-purified process, respectively. The optimized alcohol-purification process remains the marker compositions better and compared with the initial process, it's time saving and much economy. The manufacturing quality of TCM-injection can be controlled by process. PAT pattern must be designed under the well understanding of process of TCM production.

  17. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark Raymond [Univ. of California, Berkeley, CA (United States)

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 μm were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the

  18. Influence of injector technology on injection and combustion development - Part 2: Combustion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Payri, R.; Salvador, F.J.; Gimeno, J.; Morena, J. de la [CMT-Motores Termicos, Universidad Politecnica de Valencia, Camino de Vera s/n, E-46022 (Spain)

    2011-04-15

    The influence of injection technology on the fuel-air mixing process and the combustion development are analyzed by means of visualization techniques. For this purpose, two injectors (one solenoid and one piezoelectric) are characterized using an optical accessible two stroke engine. Visualization of liquid penetration has allowed the measurement of the stabilized liquid length, which is related with the efficiency of fuel-air mixing process. A theoretical derivation is used in order to relate this liquid length with chamber conditions, as well as to make a temporal analysis of these phenomena. After this, natural flame emission and chemiluminescence techniques are carried out. These results indicate that the piezoelectric system has a more efficient fuel-air mixing and combustion, reducing the characteristic times as well as soot formation. Finally, a correlation for the ignition delay of the two systems is obtained. (author)

  19. A warning system based on the RFID technology for running-out of injection fluid.

    Science.gov (United States)

    Huang, Chi-Fang; Lin, Jen-Hung

    2011-01-01

    For providing an automatic warning system of running-out of injection fluid, RFID technology is applied in this work to propose an infrastructure with low cost to help nurses and patient's company. Specially, a RFID tag is designed and attached on a bag of intravenous drip to demonstrate the benefits in the present system. The main idea of this system is that, tag is disabled when the bag is not empty because of the EM loading due to the liquid contained. The bag can be any kind in the current market and be without any electronic attachment or modification. LAN (Local Area Network) is also applied as a part of this infrastructure for data transmission.

  20. DTS technology: evaluation in steam injection pilots in PETROBRAS; Tecnologias DTS: avaliacao em pilotos de injecao de vapor na PETROBRAS

    Energy Technology Data Exchange (ETDEWEB)

    Triques, Adriana Lucia Cerri; Rodrigues, Renato Cunha; Souza, Carlos Francisco Sales de; Izetti, Ronaldo Goncalves [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    In oil and gas industry, downhole pressure and temperature distributed sensors can provide strategic information for production optimization throughout the field. Upon the successful implementation of a pilot for optical fiber distributed temperature monitoring of observer wells in a steam injection field, two new pilots have been implemented to also monitor injectors and producers in both cyclic and continuous injection fields strongly influenced by H2S. The pilots demonstrated that this technology is suitable to monitor producers in onshore fields under the conditions above without risks to the production. The sensors did not prove to be suitable for long term monitoring of injectors under continuous steam injection if fiber is installed inside the injection tubing. For cyclic injection applications, the development of steam injection packers is needed to guarantee casing integrity during the injection cycle. The application of the technology in offshore wells is nowadays restricted to dry completion situation. The potential applicability in submarine wells is tightly linked to the development of downhole and wellhead wet mate optical fiber connectors. (author)

  1. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  2. Vitellointestinal Duct Anomalies in Infancy

    OpenAIRE

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: paten...

  3. Magnetohydrodynamics in rectangular ducts

    International Nuclear Information System (INIS)

    Lenhart, L.

    1994-04-01

    Magnetohydrodynamic flow in straight ducts or bends is a key issue, which has to be investigated for developing self-cooled liquid metal blankets of fusion reactors. The code presented solves the full set of governing equations and simulates all phenomena of such flows, including inertial effects. The range of application is limited by computer storage only. (orig./WL)

  4. Anatomic relationship of intrahepatic bile ducts to portal veins revisited

    International Nuclear Information System (INIS)

    Bret, P.M.; Stempel, J.; Atri, M.; Lough, J.O.; Illescas, F.F.

    1987-01-01

    It is well accepted that intrahepatic bile ducts lie in front of corresponding portal vein branches. Since the authors' clinical experience with US was different, they studied 18 normal necropsy cadaver livers. The common bile duct, main portal vein, and hepatic artery were cannulated and injected respectively with air, dilute contrast medium, and mineral oil. The livers were then examined in anatomic position with CT. In the left lobe of the liver, the bile ducts were anterior to the portal vein in seven cases, posterior in seven cases, and were tortuous both anterior and posterior in three cases. In the right lobe, the bile ducts were anterior in nine cases, posterior in five cases, tortuous in one case, and not seen in two cases. In the porta hepatis, the bile ducts were anterior in eight cases, posterior in one case, tortuous in five cases, and not seen in three cases. Histologic specimens confirmed the anterior and posterior location of the bile ducts relative to the portal veins. In conclusion, intrahepatic bile ducts can be either anterior or posterior to the corresponding portal vein branches

  5. Reciprocity principle in duct acoustics

    Science.gov (United States)

    Cho, Y.-C.

    1979-01-01

    Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.

  6. New pellet production and acceleration technologies for high speed pellet injection system 'HIPEL' in large helical device

    International Nuclear Information System (INIS)

    Viniar, I.; Sudo, S.

    1994-12-01

    New technologies of pellet production and acceleration for fueling and diagnostics purposes in large thermonuclear reactors are proposed. The technologies are intended to apply to the multiple-pellet injection system 'HIPEL' for Large Helical Device of NIFS in Japan. The pellet production technology has already been tested in a pipe-gun type pellet injector. It will realize the repeating pellet injection by means of decreasing of the pellet formation time into the pipe-gun barrel. The acceleration technology is based upon a new pump tube operation in two-stage gas gun and also upon a new conception of the allowable pressure acting on a pellet into a barrel. Some preliminary estimations have been made, and principles of a pump tube construction providing for a reliable long term operation in the repeating mode without any troubles from a piston are proposed. (author)

  7. EKSTRAHEPATIC BILE DUCT CANCER

    OpenAIRE

    Aleš Tomažič; Dragan Stanisavljevič; Valentin Sojar; Blaž Trotovšek

    2003-01-01

    Background. Malignant strictures involving the bile ducts remain a major challenge in biliary surgery. It is an uncommon cancer. The etiology is unknown, most cases are sporadic, but several conditions confer an incrised risk of developing cholangiocarcinoma.Clinical presentation and preoperative evaluation. The early simptoms are nonspecific. In the past computed tomography, percutaneous transhepatic cholangiography and angiography were considered standard investigations, but currently magne...

  8. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  9. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    Energy Technology Data Exchange (ETDEWEB)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein [Center of Excellence for Power System Automation and Operation, Electrical Engineering Department, Iran University of Science and Technology (IUST), Tehran (Iran, Islamic Republic of)], E-mail: heydari@iust.ac.ir, E-mail: faramarz_faghihi@ee.iust.ac.ir, E-mail: reza_sharifi@ee.iust.ac.ir, E-mail: amirhosseinp@ee.iust.ac.ir

    2008-09-15

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT.

  10. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    Science.gov (United States)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein

    2008-09-01

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT.

  11. Characterization of gas reburning-sorbent injection technology by-products

    International Nuclear Information System (INIS)

    Mattigod, S.V.; Rai, D.

    1992-01-01

    This paper reports that three samples of fly ashes from pilot-scale tests of gas reburning and sorbent injection (GR-SI) technology were characterized physically, chemically, and mineralogically. Texturally, the samples consist of approximately 97% of the total mass of the sample on average. Approximately 3% of the sample mass consisted of the elements Cl, Mg, P, K, Na, and Ti, and ).4% consisted of trace elements. Major crystalline compounds found in these samples were lime (CaO), anhydrite (CaSO 4 ), and calcium carbonate (CaCO 3 ). The morphology and chemistry of particles in GR-SI samples were similar to those of particles in conventional coal fly ashes. Most of the particles were calcerous. Silicate and alumino-silicate particles were fewer in number, and iron-rich particles were rare. The EP test indicated that extract concentrations of Ag, As, Ba, Cd, Cr, Pb, and Se were sell below the EPA regulatory levels. Predictions of leachate compositions from these types of fly ashes, if disposed of as a landfill at a midwestern U.S. site indicate, that during the first ten years the concentrations of Ca, SO 4 , Na, b, and OH would remain high. The concentrations of minor constituents (As, Ba, Cd, Cd, cu, Cr, Fe, Ni, and Se) in the leachate are predicted to be at trace levels

  12. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    International Nuclear Information System (INIS)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein

    2008-01-01

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT

  13. Rare bile duct anomaly: B3 duct draining to gallbladder

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2016-01-01

    Full Text Available A 10-year-old girl presented with recurrent right upper abdominal pain and dyspepsia. Magnetic resonance cholangiopancreatography revealed a dilated common channel of intrahepatic bile duct of segment 3 (B3 and segment 4 (B4 drained into the gallbladder directly. The patient underwent laparoscopic cholecystectomy and Roux-en Y hepaticojejunostomy (B3-jejunostomy. Among the anatomical variability of the biliary system, the cholecystohepatic ducts are controversial in existence and incidence. We report a very rare variant of a cholecystohepatic duct in which the B3 duct drained into gallbladder directly and to the best of our knowledge this is the first report.

  14. Radiation resistant ducted superconductive coil

    International Nuclear Information System (INIS)

    Schleich, A.

    1976-01-01

    The radiation-resistant ducted superconductive coil consists of a helically wound electrical conductor constituted by an electrically conductive core of superconductive material provided with a longitudinally extending cooling duct. The core is covered with a layer of inorganic insulating material and the duct is covered by an electrically conductive metallic gas-tight sheath. The metallic sheaths on adjacent turns of the coil are secured together. 2 Claims, 4 Drawing Figures

  15. Duct having oscillatory side wall

    Science.gov (United States)

    Sprouse, Kenneth M.

    2018-04-03

    A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.

  16. Transcystic duct treatment of common bile duct stones

    International Nuclear Information System (INIS)

    Amberg, J.R.; Chun, G.

    1981-01-01

    Successful removal of 2 retained common bile duct stones following cholecystostomy is described. With the use of the steerable catheter and the wire basket, one stone was crushed and the second was extracted in retrograde fashion through the cystic duct and gallbladder. (orig.)

  17. ELECTROKINETICS, INC. INSITU BIO REMEDIATION BY ELECTROKINETIC INJECTION EMERGING TECHNOLOGY SUMMARY

    Science.gov (United States)

    Electrokinetics, Inc. through a cooperative agreement with USEPA's NRMRL conducted a laboratory evaluation of electrokinetic transport as a means to enhance in-situ bioremediation of trichloroethene (TCE). Four critical aspects of enhancing bioremediation by electrokinetic inject...

  18. Addressing key science and technology issues for IFE chambers, target fabrication and target injection

    International Nuclear Information System (INIS)

    Meier, W.R.; Goodin, D.T.; Nobile, A.

    2003-01-01

    Significant progress has been made in the development of high repetition rate chambers, target fabrication and injection for inertial fusion energy (IFE) for both heavy ion and laser drivers. Research is being conducted in a coordinated manner by national laboratories, universities and industry. This paper provides an overview of U.S. research activities and discusses how interface considerations (such as beam propagation and target survival during injection) impact design choices. (author)

  19. Creation of Polyurethane Injection Materials, Their Pilot-industrial Production, Development and Industrial Introduction of the Technology of Strengthening and Restoring the Operability of Damaged Constructions and Buildings

    Directory of Open Access Journals (Sweden)

    Marukha, V.І.

    2015-01-01

    Full Text Available Polyurethane and foam polyurethane fluid injection materials not conceding foreign analogues and technology technology of restoration and strengthening the operability of concrete and reinforced concrete structures and buildings damaged by cracks were developed. Normative and technical documentation on the injection materials and technological processes was created. The diagnosticrestoring complex for implementing the above technologies was designed, installed and utilized at the construction sites. The equipment is designed and manufactured; the technology of the research and industrial production of «A» and «B» components of injecting polyurethane materials is designed and developed. The pilot-scale batch is manufactured. Technological processes of preparation and application of the «A» and «B» componentsof the injecting materials in industrial conditions are worked out and implemented.

  20. Propagation of sound waves in ducts

    DEFF Research Database (Denmark)

    Jacobsen, Finn

    2000-01-01

    Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described.......Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described....

  1. Sample and injection manifolds used to in-place test of nuclear air-cleaning system

    International Nuclear Information System (INIS)

    Qiu Dangui; Li Xinzhi; Hou Jianrong; Qiao Taifei; Wu Tao; Zhang Jirong; Han Lihong

    2012-01-01

    Objective: According to the regulations of nuclear safety rules and related standards, in-place test of the nuclear air-cleaning systems should be carried out before and during operation of the nuclear facilities, which ensure them to be in good condition. In some special conditions, the use of sample and injection manifolds is required to make the test tracer and ventilating duct air fully mixed, so as to get the on-spot typical sample. Methods: This paper introduces the technology and application of the sample and injection manifolds in nuclear air-cleaning system. Results: Multi point injection and multi point sampling technology as an effective experimental method, has been used in a of domestic and international nuclear facilities. Conclusion: The technology solved the problem of uniformly of on-spot injection and sampling,which plays an important role in objectively evaluating the function of nuclear air-cleaning system. (authors)

  2. Environmental Technology Verification: Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems--American Ultraviolet Corporation, DC24-6-120 [EPA600etv08005

    Science.gov (United States)

    The Air Pollution Control Technology Verification Center (APCT Center) is operated by RTI International (RTI), in cooperation with EPA's National Risk Management Research Laboratory. The APCT Center conducts verifications of technologies that clean air in ventilation systems, inc...

  3. Intraductal papillary neoplasm of the bile duct: a case report.

    Science.gov (United States)

    Peeters, Karen; Delvaux, Peter; Huysentruyt, Frederik

    2017-08-01

    Intraductal papillary neoplasm of the bile duct (IPNB) is a rare variant of bile duct tumors, characterized by papillary growth within the bile duct lumen and is regarded as a biliary counterpart of intraductal papillary mucinous neoplasm (IPMN) of the pancreas. IPNBs are mainly found in patients from Far Eastern areas, where hepatolithiasis and clonorchiasis are endemic. The Western experience, however, remains limited. In this article, we report a 56-year-old man, referred to our hospital because of deranged liver function tests. Further imaging modalities showed a cystic lesion of 9 cm diameter, arising from the left hepatic duct. Inlying was a heterogeneous, lobulated mass. The patient underwent a left hemihepatectomy and adjuvant chemotherapy. Despite recent advanced technologies, diagnosis of IPNB is still challenging, especially in western countries due to its rarity. Early identification and resection of lesions, even in asymptomatic or minimally symptomatic patients, are however important prognostic factors.

  4. A field test of a waste containment technology using a new generation of injectable barrier liquids

    International Nuclear Information System (INIS)

    Moridis, G.; Apps, J.; Persoff, P.; Myer, L.; Muller, S.; Pruess, K.; Yen, P.

    1996-08-01

    A first stage field injection of a new generation of barrier liquids was successfully completed. Two types of barrier liquids, colloidal silica (CS) and polysiloxane (PSX), were injected into heterogeneous unsaturated deposits of sand, silt, and gravel typical of many of the arid DOE cleanup sites and particularly analogous to the conditions of the Hanford Site. Successful injection by commercially available chemical grouting equipment and the tube-a-manchette technique was demonstrated. Excavation of the grout bulbs permitted visual evaluation of the soil permeation by the grout, as well as sample collection. Both grouts effectively permeated all of the formation. The PSX visually appeared to perform better, producing a more uniform and symmetric permeation regardless of heterogeneity, filling large as well as small pores and providing more structural strength than the CS. Numerical simulation of the injection tests incorporated a stochastic field to represent site heterogeneity and was able to replicate the general test behavior. Tiltmeters were used successfully to monitor surface displacements during grout injection

  5. The impact of duct-to-duct interaction on the hex duct dilation

    International Nuclear Information System (INIS)

    Lee, M.J.; Chang, L.K.; Lahm, C.E.; Porter, D.L.

    1992-01-01

    Dilation of the hex duct is an important factor in the operational lifetime of fuel subassemblies in liquid metal fast reactors. It is caused primarily by the irradiation-enhanced creep and void swelling of the hex duct material. Excessive dilation may jeopardize subassembly removal from the core or cause a subassembly storage problem where the grid size of the storage basket is limited. Dilation of the hex duct in Experimental Breeder Reactor II (EBR-II) limits useful lifetime because of these storage basket limitations. It is, therefore, important to understand the hex duct dilation behavior to guide the design and in-core management of fuel subassemblies in a way that excessive duct deformation can be avoided. To investigate the dilation phenomena, finite-element models of the hex duct have been developed. The inelastic analyses were performed using the structural analysis code, ANSYS. Both Type 316 and D9 austenitic stainless steel ducts are considered. The calculated dilations are in good agreement with profilometry measurements made after irradiation. The analysis indicates that subassembly interaction is an important parameter in addition to neutron fluence and temperature in determining hex duct dilation. 5 refs

  6. Postoperative Biliary Leak Treated with Chemical Bile Duct Ablation Using Absolute Ethanol: A Report of Two Cases.

    Science.gov (United States)

    Sasaki, Maho; Hori, Tomohide; Furuyama, Hiroaki; Machimoto, Takafumi; Hata, Toshiyuki; Kadokawa, Yoshio; Ito, Tatsuo; Kato, Shigeru; Yasukawa, Daiki; Aisu, Yuki; Kimura, Yusuke; Takamatsu, Yuichi; Kitano, Taku; Yoshimura, Tsunehiro

    2017-08-08

    BACKGROUND Postoperative bile duct leak following hepatobiliary and pancreatic surgery can be intractable, and the postoperative course can be prolonged. However, if the site of the leak is in the distal bile duct in the main biliary tract, the therapeutic options may be limited. Injection of absolute ethanol into the bile duct requires correct identification of the bile duct, and balloon occlusion is useful to avoid damage to the surrounding tissues, even in cases with non-communicating biliary fistula and bile leak. CASE REPORT Two cases of non-communicating biliary fistula and bile leak are presented; one case following pancreaticoduodenectomy (Whipple's procedure), and one case following laparoscopic cholecystectomy. Both cases were successfully managed by chemical bile duct ablation with absolute ethanol. In the first case, the biliary leak occurred from a fistula of the right posterior biliary tract following pancreaticoduodenectomy. Cannulation of the leaking bile duct and balloon occlusion were achieved via a percutaneous route, and seven ablation sessions using absolute ethanol were required. In the second case, perforation of the bile duct branch draining hepatic segment V occurred following laparoscopic cholecystectomy. Cannulation of the bile duct and balloon occlusion were achieved via a transhepatic route, and seven ablation sessions using absolute ethanol were required. CONCLUSIONS Chemical ablation of the bile duct using absolute ethanol is an effective treatment for biliary leak following hepatobiliary and pancreatic surgery, even in cases with non-communicating biliary fistula. Identification of the bile duct leak is required before ethanol injection to avoid damage to the surrounding tissues.

  7. Extracorporeal shock-wave lithotripsy of bile duct stones

    International Nuclear Information System (INIS)

    Lee, Jong Tae; Kim, Myung Joon; Yoo, Hyung Sik; Suh, Jung Ho; Lee, Moo Sang; Jo, Jang Hwan; Kim, Byung Ro

    1989-01-01

    During the past one and half year, we performed ESWL therapy in 13 patients with common bile duct and intrahepatic duct stones, applying Lithostar-R (Siemens co. West Germany) and analyzed their results. In 13 patients, 9 residual common bile duct stones and 7 intrahepatic duct stones were selected postoperatively. The size of stones were ranged from 0.7 cm to 3.5 cm in diameter. 2 stones were multiple and the remained 14 were single in number. The visualization of stones were done with fluoroscopy after the injection of contrast media via cholangiographic T-tube or ERCP. ESWL were applied continuously until stone disintegration was visible, or upto maximum number of 3500 discharge of shock wave. If not disintegrated upto 3500, patients were underwent second or third lithotripsy session with interval of one week. Our results showed that among 9 common bile duct stones, 4 were completely disintegrated and passed out spontaneously, but 3 partially fragmented and removed by the additional procedure. 2 were failed. Among 7 intrahepatic stones, 3 completely and 2 partially were succeeded. One stone partially fragmented were retained without removal and other one were failed. Skin petechia in all patients were revealed on the entry port of shock wave, but no serous complication was not occurred

  8. Extracorporeal shock-wave lithotripsy of bile duct stones

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Kim, Myung Joon; Yoo, Hyung Sik; Suh, Jung Ho; Lee, Moo Sang; Jo, Jang Hwan; Kim, Byung Ro [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    During the past one and half year, we performed ESWL therapy in 13 patients with common bile duct and intrahepatic duct stones, applying Lithostar-R (Siemens co. West Germany) and analyzed their results. In 13 patients, 9 residual common bile duct stones and 7 intrahepatic duct stones were selected postoperatively. The size of stones were ranged from 0.7 cm to 3.5 cm in diameter. 2 stones were multiple and the remained 14 were single in number. The visualization of stones were done with fluoroscopy after the injection of contrast media via cholangiographic T-tube or ERCP. ESWL were applied continuously until stone disintegration was visible, or upto maximum number of 3500 discharge of shock wave. If not disintegrated upto 3500, patients were underwent second or third lithotripsy session with interval of one week. Our results showed that among 9 common bile duct stones, 4 were completely disintegrated and passed out spontaneously, but 3 partially fragmented and removed by the additional procedure. 2 were failed. Among 7 intrahepatic stones, 3 completely and 2 partially were succeeded. One stone partially fragmented were retained without removal and other one were failed. Skin petechia in all patients were revealed on the entry port of shock wave, but no serous complication was not occurred.

  9. Vitellointestinal Duct Anomalies in Infancy.

    Science.gov (United States)

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5-9 of intrauterine life. This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality.

  10. 2D temperature field measurement in a direct-injection engine using LIF technology

    Science.gov (United States)

    Liu, Yongfeng; Tian, Hongsen; Yang, Jianwei; Sun, Jianmin; Zhu, Aihua

    2011-12-01

    A new multi-spectral detection strategy for temperature laser- induced- fluorescence (LIF) 2-D imaging measurements is reported for high pressure flames in high-speed diesel engine. Schematic of the experimental set-up is outlined and the experimental data on the diesel engine is summarized. Experiment injection system is a third generation Bosch high-pressure common rail featuring a maximum pressure of 160MPa. The injector is equipped with a six-hole nozzle, where each hole has a diameter of 0.124 mm. and slightly offset to the center of the cylinder axis to allow a better cooling of the narrow bridge between the exhaust valves. The measurement system includes a blower, which supplied the intake flow rate, and a prototype single-valve direct injection diesel engine head modified to lay down the swirled-type injector. 14-bit digital CCD cameras are employed to achieve a greater level of accuracy in comparison to the results of previous measurements. The temperature field spatial distributions in the cylinder for different crank angle degrees are carried out in a single direct-injection diesel engine.

  11. The influence of technological parameters on the dynamic behavior of "liquid wood" samples obtained by injection molding

    Science.gov (United States)

    Plavanescu Mazurchevici, Simona; Carausu, Constantin; Comaneci, Radu; Nedelcu, Dumitru

    2017-10-01

    The plastic products contribute to environmental pollution. Replacing the plastic materials with biodegradable materials with superior properties is an absolute necessity and important research direction for the near future. The first steps in this regard were the creation of composite materials containing natural fibers with positive effects on the environment that have penetrated in different fields. The bioplastics and biocomposites made from natural fibers is a topical solution. The next step was made towards obtaining biodegradable and recyclable materials based on cellulose, lignin and no carcinogens. In this category fall the "liquid wood" with a use up to five times without affecting the mechanical properties. "Liquid wood" is a high quality thermoplastic biocomposite. "Liquid wood" is a biopolymer composite divided in three categories, ARBOFORM®, ARBOBLEND® and ARBOFILL®, which have differed composition in terms of lignin percentage, being delivered by Tecnaro, as granules, [1]. The paper's research was focus on Arboform L V3 Nature and Arboform L V3 Nature reinforced with aramid fiber. In the experimental plan were taken into account six parameters (Dinj - direction of injection [°]; Ttop - melting temperature [°C]; Pinj - injection pressure [MPa] Ss - speed [m/min]; tinj - injection time [s] and tc - cooling time [s]) each with two levels, research carried on by Taguchi methodology. Processing Taguchi method allowed both Taguchi setting work parameters influence on storage modulus and damping as the size and influence their ranking. Experimental research concerning the influence technological parameters on storage modulus of samples obtained by injection from Arboform L V3 Nature yielded an average of 6055MPa and descending order as follows: Trac, Ss, Pinj, Dinj and Ttop. The average of model for reinforced material was 6419MPa and descending order of parameters influence such as: Dinj, Trac, Ttop, tinj, Ss and Pinj.

  12. [Application of near-infrared spectroscopy technology in extraction and concentration process of Reduning injection].

    Science.gov (United States)

    Zhang, Ya-Fei; Zuo, Xiang-Yun; Bi, Yu-An; Wu, Jian-Xiong; Wang, Zhen-Zhong; L, Ping; Xiao, Wei

    2014-08-01

    To establish a rapid quantitative analysis method for the content of chlorogenic acid and solid content in the extraction liquid concentration process during the production of Reduning injection by using the near-infrared (NIR) spectroscopy, in order to reflect the concentration state in a real-time manner and really realize the quality control of concentrating process of the extraction and concentration process. The samples during the Jinqing extraction liquid concentration process were collected. After the removal of abnormal samples, the spectra pretreatment and the wave band selection, the quantitative calibration model between NIR spectra and chlorogenic acid HPLC analytical value and solid content was established by using PLS algorithm, and unknown samples were predicted. The correlation coefficients between the chlorogenic acid content and the solid content were respectively 0.992 1 and 0.994 0, and the correlation coefficients of the verification model were respectively 0.994 4 and 0.998 4, with the root mean square error of calibration (RMSEC) of 0.814 6 and 2.656 1 and the root mean square error of prediction (RMSEP) of 0.704 6 and 1.876 7 respectively, and the relative standard errors of predictions (RSEP) were 6.01% and 2.93% respectively. The method is simple, rapid, nondestructive, accurate and reliable, thus could be adopted for the fast monitoring of the chlorogenic acid content and the solid content during the concentration process of Reduning injection extraction liquid.

  13. An experimental study on microcholangiographic manifestation in extrahepatic bile duct obstruction

    International Nuclear Information System (INIS)

    Lee, Yul; Kang, Heung Sik; Park, Jae Hyung; Kim, Chu Wan

    1987-01-01

    Microcholangiographic using microbarium was done for radiological observation of the morphology of intrahepatic microbiliary system and its charge after extrahepatic bile duct obstruction. Regurgitation of microbarium into the systemic circulation was also observed. Extrahepatic bile ducts of 40 rabbits were ligated and microcholangiography was done just after ligation, after 1 day, 3 days and 5 days. Injection pressure of microbarium was 58 cm H 2 O in 20 rabbits and 93 cm H 2 O in another 20 rabbits. Histologic findings of the liver was compared with microcholangiographic findings. The results were as follows: 1. In microcholangiography, interlobular bile ducts and ductules were well noted, but bile canaliculi were not visible. 2. After extrahepatic bile duct ligation, ductules and small interlobular bile ducts were tortuously dilated and proliferated. These findings progressed according as the time after extrahepatic bile duct ligation especially between 1 and 2 days. 3. Microbarium was regurgitated into hepatic sinusoids from a portal tract due to rupture of interlobular bile ducts or ductules, and this was observed only in limited portions of sample tissue sections, but could be found in most of 40 rabbits. From the above results, the morphology of intrahepatic microbiliary system and its change after extrahepatic bile duct obstruction could be radiologically observed with microcholangiography, so this technique could be used for experimental study about the biliary system.

  14. Choice of technological regimes of a blast furnace operation with injection of hot reducing gases

    Directory of Open Access Journals (Sweden)

    Babich, A. I.

    2002-08-01

    Full Text Available Injection rate of fossil fuels is limited because of drop in the flame temperature in the raceway and problems in the deadman region and the cohesive zone. The next step for obtaining a considerable coke saving, a better operation in the deadman as an well as increase in blast furnace productivity and minimizing the environmental impact due to a decrease in carbon dioxide emmision would be injection by tuyeres of hot reducing gases (HRG which are produced by low grade coal gasification or top gas regenerating. Use of HRG in combination with high pulverized coal inyection PCI rate and oxigen enrichment in the blast could allow to keep and to increase the competitiveness of the blast furnace process. Calculations using a mathematical model show that the HRG injection in combination with pulverized coal (PC and enriching blast with oxigen can provide an increase in PC rate up to 300-400 kg/tHM and a rise in the furnace productivity by 40-50 %. Blast furnace operation with full oxigen blast (100 % of process oxigen with the exception for the hot blast is possible when HRG is injected.

    La tasa de inyección de combustibles fósiles está limitada a causa de la caída de la temperatura de llama en el raceway (cavidad frente a las toberas y a problemas en la región del "hombre muerto" y en la zona cohesiva. La inyección por tobera de gases reductores calientes (GRC, que se producen por gasificación de carbón de bajo grado o generación de gas de tragante, será la próxima etapa para lograr un considerable ahorro adicional de coque, una zona del "hombre muerto" bien definida, además de un aumento en la productividad del horno alto y para minimizar el impacto ambiental debido a una disminución de la emisión de dióxido de carbono. El uso de GRC en combinación con una tasa elevada de inyección de carbón pulverizado (ICP con viento enriquecido en oxígeno, podrá permitir mantener y aumentar la competitividad del proceso del horno

  15. Injection seeded, diode pumped regenerative ring Nd:YAG amplifier for spaceborne laser ranging technology development

    Science.gov (United States)

    Coyle, D. Barry; Kay, Richard B.; Degnan, John J.; Krebs, Danny J.; Seery, Bernard D.

    1992-01-01

    A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.

  16. CO2 injection into submarine, CH4-hydrate bearing sediments: Parameter studies towards the development of a hydrate conversion technology

    Science.gov (United States)

    Deusner, Christian; Bigalke, Nikolaus; Kossel, Elke; Haeckel, Matthias

    2013-04-01

    the reservoir is minimized. Our results clearly indicate that the formation of mixed CH4-CO2-hydrates is an important aspect in the conversion process. The experimental studies have shown that the injection of heated CO2 into the hydrate reservoir induces a variety of spatial and temporal processes which result in substantial bulk heterogeneity. Current numerical simulators are not able to predict these process dynamics and it is important to improve available transport-reaction models (e.g. to include the effect of bulk sediment permeability on the conversion dynamics). Our results confirm that experimental studies are important to better understand the mechanisms of hydrate dissociation and conversion at CO2-injection conditions as a basis towards the development of a suitable hydrate conversion technology. The application of non-invasive analytical methods such as Magnetic Resonance Imaging (MRI) and Raman microscopy are important tools, which were applied to resolve process dynamics on the pore scale. Additionally, the NESSI system is being modified to allow high-pressure flow-through experiments under triaxial loading to better simulate hydrate-sediment mechanics. This aspect is important for overall process development and evaluation of process safety issues.

  17. Hybrid tooling technologies and standardization for the manufacturing of inserts for micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Fillon, Bertrand; Azcarate, Sabino

    2007-01-01

    This paper is based on the European Platform’s activities within the 4M Network of Excellence “Multi-Material Micro Manufacturing”. To overpass limitations of the current existing micro tooling capabilities, a new generation of micro hybrid tooling technologies for micro replication was developed....... A metrological approach was applied to standardize the employed tooling processes (micro milling, µEDM, laser micromachining, electrochemical µ-milling). The micro tools were then tested with different polymers (PP, PP + nano fillers, PC, COC). The paper provides a comparison of these technologies concerning...

  18. A novel duct-lobular segmentectomy for breast tumors with nipple discharge using near-infrared indocyanine green fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ohno

    2013-10-01

    Full Text Available A 44-year-old woman was referred to our hospital with pathological nipple discharge from her left breast. Ultrasonography revealed a solid tumor beneath her left areola that measured 17 mm in diameter with a dilated mammary duct. Contrast-enhanced magnetic resonance imaging showed an early-enhanced cystic tumor and a dilated mammary duct. We performed a duct-lobular segmentectomy using near-infrared indocyanine green (ICG-fluorescence imaging. Under general anesthesia, a silicone tube was inserted into an orifice of a fluid-discharging mammary duct, and 1 mL dye-fluorescence liquid containing ICG and indigo carmine was injected into the mammary duct. A periareolar incision was made, and the fluorescence image of the demarcated mammary duct segment was obtained. The mammary duct segment was dissected, along with the demarcation line. The cystic lesion and dilated mammary duct were fully resected, and the pathological diagnosis was intraductal papilloma of the breast. We report that near-infrared ICG fluorescence could be applied for imaging of the mammary duct segment, and the fluorescence image allowed for easier duct-lobular segmentectomy for nipple discharge.

  19. Nondestructive Evaluation of the J-2X Direct Metal Laser Sintered Gas Generator Discharge Duct

    Science.gov (United States)

    Esther, Elizabeth A.; Beshears, Ronald D.; Lash, Rhonda K.

    2012-01-01

    The J-2X program at NASA's Marshall Space Flight Center (MSFC) procured a direct metal laser sintered (DMLS) gas generator discharge duct from Pratt & Whitney Rocketdyne and Morris Technologies for a test program that would evaluate the material properties and durability of the duct in an engine-like environment. DMLS technology was pursued as a manufacturing alternative to traditional techniques, which used off nominal practices to manufacture the gas generator duct's 180 degree turn geometry. MSFC's Nondestructive Evaluation (NDE) Team performed radiographic, ultrasonic, computed tomographic, and fluorescent penetrant examinations of the duct. Results from the NDE examinations reveal some shallow porosity but no major defects in the as-manufactured material. NDE examinations were also performed after hot-fire testing the gas generator duct and yielded similar results pre and post-test and showed no flaw growth or development.

  20. Should you get your heating ducts cleaned?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Canada Mortgage and Housing Corporation conducted research into duct cleaning during which time several houses were tested for hot air furnace duct performance before and after cleaning. Duct cleaning is a major industry which claims that cleaning of ducts will provide you with better indoor air quality, reduce household molds and allergens, get rid of house dust, result in more airflow and better delivery of warm air and reduce energy costs. This report does not substantiate those claims. Researchers found little or no discernible differences in the concentrations of house airborne particles or in duct airflows due to duct cleaning. This is because ducts are metal passages that cannot create dust. Most household dusts come from outdoors that has been tracked in or blows through windows and other openings. While duct cleaning may be justifiable personally, it does not change the quality of the air you breathe, nor will it significantly affect airflow or heating costs. Some filters effectively clean the air in the ducts but they do not create a dust-free environment because of the above-mentioned dust sources. The only time that duct cleaning may make sense is if you have water in your ducts that can result in mold growth, if you are moving into a newly constructed house to remove drywall dust, if your are having trouble with furnace airflow, or if you see an accumulation of debris in the return air ducts. It was emphasized that broadcast spraying of biocides within the duct system should not be performed.

  1. Biodiesel production via injection of superheated methanol technology at atmospheric pressure

    International Nuclear Information System (INIS)

    Ang, Gaik Tin; Tan, Kok Tat; Lee, Keat Teong; Mohamed, Abdul Rahman

    2014-01-01

    Highlights: • Non-catalytic superheated methanol for biodiesel production is developed. • Crude Jatropha curcas oil with high FFA can be directly used as oil feedstock. • High content of biodiesel can be produced. • Separation of FAME and glycerol from the sample product is easy. - Abstract: In this high demand of renewable energy market, biodiesel was extensively produced via various catalytic and non-catalytic technologies. Conventional catalytic transesterification for biodiesel production has been shown to have limitation in terms of sensitivity to high water and free fatty acid, complicated separation and purification of biodiesel. In this study, an alternative and innovative approach was carried out via non-catalytic superheated methanol technology to produce biodiesel. Similar to supercritical reaction, the solvent need to be heated beyond the critical temperature but the reactor pressure remained at 0.1 MPa (atmospheric pressure). Transesterification reaction with superheated methanol was carried out at different reaction temperature within the limit of 270–300 °C and at different methanol flow rate ranging from 1 ml/min to 3 ml/min for 4 h. Results obtained showed that the highest biodiesel yield at 71.54% w/w was achieved at reaction temperature 290 °C and methanol flow rate at 2 ml/min with 88.81% w/w FAME content, implying the huge potential of superheated technology in producing FAME

  2. Influence of injector technology on injection and combustion development - Part 1: Hydraulic characterization

    Energy Technology Data Exchange (ETDEWEB)

    Payri, R.; Salvador, F.J.; Gimeno, J.; Morena, J. de la [CMT-Motores Termicos, Universidad Politecnica de Valencia, Camino de Vera s/n, E-46022 (Spain)

    2011-04-15

    An experimental study of two real multi-hole Diesel injectors is performed under current DI Diesel engine operating conditions. The aim of the investigation is to study the influence of injector technology on the flow at the nozzle exit and to analyse its effect on the spray in evaporative conditions and combustion development. The injectors used are two of the most common technologies used nowadays: solenoid and piezoelectric. The nozzles for both injectors are very similar since the objective of the work is the understanding of the influence of the injector technology on spray characteristics for a given nozzle geometry. In the first part of the study, experimental measurements of hydraulic characterization have been analyzed for both systems. Analysis of spray behaviour in evaporative conditions and combustion development will be carried out in the second part of the work. Important differences between both injectors have been observed, especially in their transient opening and closing of the needle, leading to a more efficient air-fuel mixing and combustion processes for the piezoelectric actuated injector. (author)

  3. Research and application of multi-hydrogen acidizing technology of low-permeability reservoirs for increasing water injection

    Science.gov (United States)

    Ning, Mengmeng; Che, Hang; Kong, Weizhong; Wang, Peng; Liu, Bingxiao; Xu, Zhengdong; Wang, Xiaochao; Long, Changjun; Zhang, Bin; Wu, Youmei

    2017-12-01

    The physical characteristics of Xiliu 10 Block reservoir is poor, it has strong reservoir inhomogeneity between layers and high kaolinite content of the reservoir, the scaling trend of fluid is serious, causing high block injection well pressure and difficulty in achieving injection requirements. In the past acidizing process, the reaction speed with mineral is fast, the effective distance is shorter and It is also easier to lead to secondary sedimentation in conventional mud acid system. On this point, we raised multi-hydrogen acid technology, multi-hydrogen acid release hydrogen ions by multistage ionization which could react with pore blockage, fillings and skeletal effects with less secondary pollution. Multi-hydrogen acid system has advantages as moderate speed, deep penetration, clay low corrosion rate, wet water and restrains precipitation, etc. It can reach the goal of plug removal in deep stratum. The field application result shows that multi-hydrogen acid plug removal method has good effects on application in low permeability reservoir in Block Xiliu 10.

  4. Remediation of BTEX contaminated groundwater: best technology assessment between pump&treat and bioremediation by oxygen injection

    Directory of Open Access Journals (Sweden)

    Daniele Baldi

    2012-06-01

    Full Text Available The presence of benzene, toluene, ethylbenzene and xylene (BTEX dissolved in the groundwater and migrated from a light non-aqueous phase liquid (LNAPL source in an alluvial aquifer required a remedial action to be taken by the responsible party as established by the Italian regulation (Legislative Decree 152/06 and subsequent amendments. For such purpose, field investigations were conducted on site in order to define the site conceptual model and to identify the appropriate remediation technology to be applied. The remediation design was developed by means of a flow and reactive transport mathematical model, applied to saturated media, using the numerical codes MODFLOW and RT3D. Groundwater field observations showed evidence of occurring BTEX biodegradation processes by bacteria naturally present in the aquifer. Since such specific bacterial activity would be significantly enhanced by the injection of free oxygen in the aquifer, the performance of traditional pump and treat systems (P&T was assessed and compared with cost/efficiency of reactive oxygen bio-barrier technology (OD. The results showed a clear advantage in terms of cost/efficiency with the application of the OD. This presents an overall cost of about 30% of the P&T installation and maintenance, and it reaches remedial target in a shorter timeframe. Moreover, the system is also applicable as a bioremediation technology in case of Environmental Emergency Measures (MISE. The site examined is part of an industrial plant located in Central Italy.

  5. Treatment Options for Extrahepatic Bile Duct Cancer

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  6. Treatment Option Overview (Extrahepatic Bile Duct Cancer)

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  7. General Information about Extrahepatic Bile Duct Cancer

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  8. Advanced Production Surface Preparation Technology Development for Ultra-High Pressure Diesel Injection

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Marion B.

    2012-04-30

    In 2007, An Ultra High Injection Pressure (UHIP) fueling method has been demonstrated by Caterpillar Fuel Systems - Product Development, demonstrating ability to deliver U.S. Environment Protection Agency (EPA) Tier 4 Final diesel engine emission performance with greatly reduced emissions handling components on the engine, such as without NOx reduction after-treatment and with only a through-flow 50% effective diesel particulate trap (DPT). They have shown this capability using multiple multi-cylinder engine tests of an Ultra High Pressure Common Rail (UHPCR) fuel system with higher than traditional levels of CEGR and an advanced injector nozzle design. The system delivered better atomization of the fuel, for more complete burn, to greatly reduce diesel particulates, while CEGR or high efficiency NOx reduction after-treatment handles the NOx. With the reduced back pressure of a traditional DPT, and with the more complete fuel burn, the system reduced levels of fuel consumption by 2.4% for similar delivery of torque and horsepower over the best Tier 4 Interim levels of fuel consumption in the diesel power industry. The challenge is to manufacture the components in high-volume production that can withstand the required higher pressure injection. Production processes must be developed to increase the toughness of the injector steel to withstand the UHIP pulsations and generate near perfect form and finish in the sub-millimeter size geometries within the injector. This project resulted in two developments in 2011. The first development was a process and a machine specification by which a high target of compressive residual stress (CRS) can be consistently imparted to key surfaces of the fuel system to increase the toughness of the steel, and a demonstration of the feasibility of further refinement of the process for use in volume production. The second development was the demonstration of the feasibility of a process for imparting near perfect, durable geometry to

  9. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...

  10. An Integrated Heavy Fuel Piston Engine Ducted Fan Propulsion Unit for Personal Air Vehicles, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed PAVE propulsion system technology demonstration combines an innovative high-speed aero-diesel engine with a novel ducted fan assembly resulting in a low...

  11. An Integrated Heavy Fuel Piston Engine Ducted Fan Propulsion Unit for Personal Air Vehicles, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed PAVE propulsion system technology demonstration combines an innovative high-speed aero-diesel engine with a novel ducted fan assembly resulting in a low...

  12. Thoracic duct lymphography by subcutaneous contrast agent ...

    African Journals Online (AJOL)

    A second lymphography revealed a collateral thoracic duct that was not detected during the first lymphography. The collateral duct was ligated and chylothorax was resolved after the second surgery. The lymphography applied in this study was minimally-invasive and easily provided images of the thoracic duct in a dog with ...

  13. Wind Turbine With Concentric Ducts

    Science.gov (United States)

    Muhonen, A. J.

    1983-01-01

    Wind Turbine device is relatively compact and efficient. Converging inner and outer ducts increase pressure difference across blades of wind turbine. Turbine shaft drives alternator housed inside exit cone. Suitable for installation on such existing structures as water towers, barns, houses, and commercial buildings.

  14. Research on the technology of detecting the SQL injection attack and non-intrusive prevention in WEB system

    Science.gov (United States)

    Hu, Haibin

    2017-05-01

    Among numerous WEB security issues, SQL injection is the most notable and dangerous. In this study, characteristics and procedures of SQL injection are analyzed, and the method for detecting the SQL injection attack is illustrated. The defense resistance and remedy model of SQL injection attack is established from the perspective of non-intrusive SQL injection attack and defense. Moreover, the ability of resisting the SQL injection attack of the server has been comprehensively improved through the security strategies on operation system, IIS and database, etc.. Corresponding codes are realized. The method is well applied in the actual projects.

  15. Desulfurization technology in the blast furnace raceway by MgO-SiO{sub 2} flux injection

    Energy Technology Data Exchange (ETDEWEB)

    Orimoto, T.; Noda, T.; Ichida, M.; Nagasaka, T. [Hokkai Iron & Coke Corporation, Hokkaido (Japan)

    2008-07-01

    This paper presents a study on desulfurization technology in the steel industry, with attention focused on the removal of sulfur that forms acid rain, which has been creating various global problems. The study was confined to the technology that injects a mixture of serpentine and pulverized coals. Thermodynamically, a magnesium gas producing reaction occurs when magnesium oxide is turned into a hot strongly reducing atmosphere and the resulting magnesium gas forms magnesium sulfide by reaction with the sulfur in the molten iron. By dividing this desulfurization process into a magnesium gas producing reaction and a desulfurization reaction by the magnesium gas, the desulfurization effect of the magnesium oxide flux was confirmed through laboratory experiment. A thermodynamic study on the desulfurization reaction in which SiO gas resulting from the reduction of SiO{sub 2} produces a silicon sulfide gas by reaction with the sulfur in the molten iron revealed that the possibility of desulfurization of the molten iron by the silicon sulfide gas is not negligible.

  16. Evaluation of Dry Sorbent Injection Technology for Pre-Combustion CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Carl [URS Group, Inc., Austin, TX (United States); Steen, William [URS Group, Inc., Austin, TX (United States); Triana, Eugenio [URS Group, Inc., Austin, TX (United States); Machalek, Thomas [URS Group, Inc., Austin, TX (United States); Davila, Jenny [URS Group, Inc., Austin, TX (United States); Schmit, Claire [URS Group, Inc., Austin, TX (United States); Wang, Andrew [URS Group, Inc., Austin, TX (United States); Temple, Brian [URS Group, Inc., Austin, TX (United States); Lu, Yongqi [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Lu, Hong [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Zhang, Luzheng [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Ruhter, David [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Rostam-Abadi, Massoud [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Sayyah, Maryam [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Ito, Brandon [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States); Suslick, Kenneth [Illinois State Geological Survey - University of Illinois at Urbana-Champaign (United States)

    2013-09-30

    This document summarizes the work performed on Cooperative Agreement DE-FE0000465, “Evaluation of Dry Sorbent Technology for Pre-Combustion CO{sub 2} Capture,” during the period of performance of January 1, 2010 through September 30, 2013. This project involves the development of a novel technology that combines a dry sorbent-based carbon capture process with the water-gas-shift reaction for separating CO{sub 2} from syngas. The project objectives were to model, develop, synthesize and screen sorbents for CO{sub 2} capture from gasified coal streams. The project was funded by the DOE National Energy Technology Laboratory with URS as the prime contractor. Illinois Clean Coal Institute and The University of Illinois Urbana-Champaign were project co-funders. The objectives of this project were to identify and evaluate sorbent materials and concepts that were suitable for capturing carbon dioxide (CO{sub 2}) from warm/hot water-gas-shift (WGS) systems under conditions that minimize energy penalties and provide continuous gas flow to advanced synthesis gas combustion and processing systems. Objectives included identifying and evaluating sorbents that efficiently capture CO{sub 2} from a gas stream containing CO{sub 2}, carbon monoxide (CO), and hydrogen (H{sub 2}) at temperatures as high as 650 °C and pressures of 400-600 psi. After capturing the CO{sub 2}, the sorbents would ideally be regenerated using steam, or other condensable purge vapors. Results from the adsorption and regeneration testing were used to determine an optimal design scheme for a sorbent enhanced water gas shift (SEWGS) process and evaluate the technical and economic viability of the dry sorbent approach for CO{sub 2} capture. Project work included computational modeling, which was performed to identify key sorbent properties for the SEWGS process. Thermodynamic modeling was used to identify optimal physical properties for sorbents and helped down-select from the universe of possible sorbent

  17. HAARP-Induced Ionospheric Ducts

    International Nuclear Information System (INIS)

    Milikh, Gennady; Vartanyan, Aram

    2011-01-01

    It is well known that strong electron heating by a powerful HF-facility can lead to the formation of electron and ion density perturbations that stretch along the magnetic field line. Those density perturbations can serve as ducts for ELF waves, both of natural and artificial origin. This paper presents observations of the plasma density perturbations caused by the HF-heating of the ionosphere by the HAARP facility. The low orbit satellite DEMETER was used as a diagnostic tool to measure the electron and ion temperature and density along the satellite orbit overflying close to the magnetic zenith of the HF-heater. Those observations will be then checked against the theoretical model of duct formation due to HF-heating of the ionosphere. The model is based on the modified SAMI2 code, and is validated by comparison with well documented experiments.

  18. Adhesion strength between thermoplastics and its polyurethane coating made by using the technology combination of injection molding and reaction injection molding

    Science.gov (United States)

    Bloß, P.; Böhme, A.; Müller, J.; Krajewsky, P.; Michaelis, J.

    2014-05-01

    A complete equipment for injection molding (IM) of a thermoplastic (TP) carrier and reaction injection molding (RIM) of polyurethane (PUR) coatings including IM and RIM machines, a color module for PUR, and a robot was built up. A modularly composed sliding split mold was constructed and manufactured allowing different parts including thicker (2 mm thickness) soft touch and thin (0.4 mm) lacquer PUR coatings. As TP PC/ABS and PA6 GF15 compounds were used, and aromatic and aliphatic PUR systems as well. From the parts made by IM+RIM, test specimens for peel force measurements were cut. These investigations were performed prior and after ageing under climatic conditions @ 50 % RH and temperature changes between -30 °C and 90 °C. By varying IM processing parameters, we have found that mold and TP temperatures are particularly important for the adhesion strength between TP and PUR. The waiting time between the end of TP cooling and PUR injection has a minor influence on its mean value. However, to short waiting times may result in inhomogeneous adhesion. It was surprising that surface defects of the TP carrier leads also to inhomogeneous adhesion. We have observed that ageing may cause an increase and decrease of adhesions strength depending on the TP+PUR system used. We have found that the results are valid only for the actual TP and PUR combination. A generalization seems to be inappropriate, hence, the actual combination should be investigated to prevent unwanted surprises when the coated TP part is in its application.

  19. Discussion of the influence of CO and CH4 in CO2 transport, injection, and storage for CCS technology.

    Science.gov (United States)

    Blanco, Sofía T; Rivas, Clara; Bravo, Ramón; Fernández, Javier; Artal, Manuela; Velasco, Inmaculada

    2014-09-16

    This paper discusses the influence of the noncondensable impurities CO and CH4 on Carbon Capture and Storage (CCS) technology. We calculated and drew conclusions about the impact of both impurities in the CO2 on selected transport, injection, and storage parameters (pipeline pressure drop, storage capacity, etc.), whose analysis is necessary for the safe construction and operation of CO2 pipelines and for the secure long-term geological storage of anthropogenic CO2. To calculate these parameters, it is necessary to acquire data on the volumetric properties and the vapor-liquid equilibrium of the fluid being subjected to CCS. In addition to literature data, we used new experimental data, which are presented here and were obtained for five mixtures of CO2+CO with compositions characteristic of the typical emissions of the E.U. and the U.S.A. Temperatures and pressures are based on relevant CO2 pipeline and geological storage site values. From our experimental results, Peng-Robinson, PC-SAFT, and GERG Equations of State for were validated CO2+CO under the conditions of CCS. We conclude that the concentration of both impurities strongly affects the studied parameters, with CO being the most influential and problematic. The overall result of these negative effects is an increase in the difficulties, risks, and overall costs of CCS.

  20. DOE/NETL's phase II mercury control technology field testing program: preliminary economic analysis of activated carbon injection.

    Science.gov (United States)

    Jones, Andrew P; Hoffmann, Jeffrey W; Smith, Dennis N; Feeley, Thomas J; Murphy, James T

    2007-02-15

    Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal "above and beyond" the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166000/lb Hg removed.

  1. Multimodal method for scattering of sound at a sudden area expansion in a duct with subsonic flow

    NARCIS (Netherlands)

    Kooijman, G.; Testud, P.; Aurégan, Y.; Hirschberg, A.

    2008-01-01

    The scattering of sound at a sudden area expansion in a duct with subsonic mean flow has been modelled with a multimodal method. Technological applications are for instance internal combustion engine exhaust silencers and silencers in industrial duct systems. Both two-dimensional (2D) rectangular

  2. Quadcopter thrust optimization with ducted-propeller

    Directory of Open Access Journals (Sweden)

    Kuantama Endrowednes

    2017-01-01

    Full Text Available In relation to quadcopter body frame model, propeller can be categorized into propeller with ducted and without ducted. This study present differences between those two using CFD (Computational Fluid Dynamics method. Both categories utilize two blade-propeller with diameter of 406 (mm. Propeller rotation generates acceleration per time unit on the volume of air. Based on the behavior of generated air velocity, ducted propeller can be modeled into three versions. The generated thrust and performance on each model were calculated to determine the best model. The use of ducted propeller increases the total weight of quadcopter and also total thrust. The influence of this modeling were analyzed in detail with variation of angular velocity propeller from 1000 (rpm to 9000 (rpm. Besides the distance between propeller tip and ducted barrier, the size of ducted is also an important part in thrust optimization and total weight minimization of quadcopter.

  3. Thermal neutrons streaming in straight duct

    International Nuclear Information System (INIS)

    Jehouani, A.; Boulkheir, M.; Ichaoui, R.

    2000-01-01

    The neutron streaming in duct is due to two phenomena: a) direct propagation and b) reflection on duct wall. We have used the Monte Carlo method to evaluate the ratio of the reflected neutrons flux by the duct wall to the total flux at the exit of the duct for iron and aluminium. Ten neutrons energy groups are considered between 10 -5 eV and 10 eV. A Fortran program is developed to evaluate the neutron double differential albedo. It is shown that the two following approximations are largely justified: i) Three collisions in the duct wall are sufficient to attain the asymptotic limit of the multiscattered neutron double differential albedo ii) The points of entry and exit of the neutron in the duct wall may be considered the same for the multiscattered neutrons. For a punctual source at the mouth of the duct, we have determined the direct and the reflected part of the total thermal neutron flux at the exit of the duct for different lengths and different radius of the duct. For a punctual source, we have found that the major contribution to the total flux of neutrons at the exit is due to the neutron reflection by walls and the reflection contribution decreases when the neutron energy decreases. For a constant length of the duct, the reflected part decreases when the duct radius increases while for the disk shaped source we have found the opposite phenomena. The transmitted neutron flux distribution at the exit of the duct are determined for disk shaped source for different neutron energy and for different distance from the exit center. (author)

  4. Molecular Mechanisms of Bile Duct Development

    OpenAIRE

    Zong, Yiwei; Stanger, Ben Z.

    2010-01-01

    The mammalian biliary system, consisting of the intrahepatic and extrahepatic bile ducts, is responsible for transporting bile from the liver to the intestine. Bile duct dysfunction, as is seen in some congenital biliary diseases such as Alagille syndrome and biliary atresia, can lead to the accumulation of bile in the liver, preventing the excretion of detoxification products and ultimately leading to liver damage. Bile duct formation requires coordinated cell-cell interactions, resulting in...

  5. Persistent Mullerian Duct Syndrome with Transverse Testicular ...

    African Journals Online (AJOL)

    Eastham JA, McEvoy K, Sullivan R, Chandrasoma P. A case of simultaneous bilateral nonseminomatous testicular tumors in persistent müllerian duct syndrome. J Urol 1992;148:407-8. 8. Shinmura Y, Yokoi T, Tsutsui Y. A case of clear cell adenocarcinoma of the müllerian duct in persistent müllerian duct syndrome: The first ...

  6. Parotid salivary duct stenosis following caudal maxillectomy.

    Science.gov (United States)

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy.

  7. ITER L 7 duct remote handling equipment design report

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The operation, design and interfaces of the 'Duct Vehicle' and it's associated remote handling equipment are briefly described in this document. This equipment is being designed by Spar Aerospace Ltd. for the Divertor Test Platform as part of ITER Research and Development Project L-7. Canadian Fusion Fuels Technology Project funds this work as part of the Canadian Contribution to ITER. This document describes the equipment design status at the September 1996 design review. 23 figs

  8. Nasopalatine duct cyst: A case report

    Directory of Open Access Journals (Sweden)

    Saikrishna Pasupuleti

    2015-01-01

    Full Text Available Nasopalatine duct cyst (NPDC is the most common non-odontogenic cyst of oral cavity. Clinically, Nasopalatine duct cyst manifests as an asymptomatic swelling of the palate or the upper lip. Radiographically, it is seen as a heart-shaped radiolucency and can be confused with periapical pathology. The aim of this article is to report a case of a nasopalatine duct cyst in a 36-year-old patient which was misinterpreted for a periapical cyst. Diagnosis of a Nasopalatine duct cyst can be given through clinical, radiographical, and histopathological examination.

  9. Future technology of the spark-ignition engine: spray-guided direct injection with piezo injector; Die Zukunftstechnologie des Ottomotors: Strahlgefuehrte Direkteinspritzung mit Piezo-Injektor

    Energy Technology Data Exchange (ETDEWEB)

    Waltner, A.; Lueckert, P.; Schaupp, U.; Rau, E.; Kemmler, R.; Weller, R. [DaimlerChrysler AG, Stuttgart (Germany)

    2006-07-01

    The completely new-style second-generation direct-injection for spark-ignition engines from Mercedes-Benz offers clear improvements in fuel consumption, power and emission levels. Faced with the necessity of further reducing fuel consumption, primarily in spark-ignition engines, the Mercedes-Benz combustion system represents a significant leap in technology. It was possible to noticeably expand the mapping range in which stratified operation can be used compared with the first generation. This significant improvement in efficiency results in more useable energy and a substantial reduction in consumption in city traffic, and also on cross-country and highway trips at roughly constant speeds. These benefits make themselves felt not only in the test cycle, but also in the real-world consumption achieved by the customer. Development proceeded from the base aspirated engine on the principle of the modular expansion of technology. Since production development of this combustion system was not possible using the hydraulic and ignition components available on the market, a new outward-opening piezo fuel injector had to be developed for production readiness, along with a 200-bar high-pressure fuel system, which is being introduced here for the first time world-wide. The injection spray stability and excellent mixture preparation that it achieves produce an optimally combustible mixture at the spark plug. The potential of multiple injection, along with stability in stratified operation, brings further benefits and possibilities for direct injection in fuel consumption and emissions. (orig.)

  10. Measure Guideline: Sealing and Insulating of Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  11. Measure Guideline. Sealing and Insulating Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Puttagunta, S. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  12. Continuous atmospheric monitoring of the injected CO2 behavior over geological storage sites using flux stations: latest technologies and resources

    Science.gov (United States)

    Burba, George; Madsen, Rodney; Feese, Kristin

    2014-05-01

    Flux stations have been widely used to monitor emission rates of CO2 from various ecosystems for climate research for over 30 years [1]. The stations provide accurate and continuous measurements of CO2 emissions with high temporal resolution. Time scales range from 20 times per second for gas concentrations, to 15-minute, hourly, daily, and multi-year periods. The emissions are measured from the upwind area ranging from thousands of square meters to multiple square kilometers, depending on the measurement height. The stations can nearly instantaneously detect rapid changes in emissions due to weather events, as well as changes caused by variations in human-triggered events (pressure leaks, control releases, etc.). Stations can also detect any slow changes related to seasonal dynamics and human-triggered low-frequency processes (leakage diffusion, etc.). In the past, station configuration, data collection and processing were highly-customized, site-specific and greatly dependent on "school-of-thought" practiced by a particular research group. In the last 3-5 years, due to significant efforts of global and regional CO2 monitoring networks (e.g., FluxNet, Ameriflux, Carbo-Europe, ICOS, etc.) and technological developments, the flux station methodology became fairly standardized and processing protocols became quite uniform [1]. A majority of current stations compute CO2 emission rates using the eddy covariance method, one of the most direct and defensible micrometeorological techniques [1]. Presently, over 600 such flux stations are in operation in over 120 countries, using permanent and mobile towers or moving platforms (e.g., automobiles, helicopters, and airplanes). Atmospheric monitoring of emission rates using such stations is now recognized as an effective method in regulatory and industrial applications, including carbon storage [2-8]. Emerging projects utilize flux stations to continuously monitor large areas before and after the injections, to locate and

  13. Ducted wind turbine optimization : A numerical approach

    NARCIS (Netherlands)

    Dighe, V.V.; De Oliveira Andrade, G.L.; van Bussel, G.J.W.

    2017-01-01

    The practice of ducting wind turbines has shown a beneficial effect on the overall performance, when compared to an open turbine of the same rotor diameter1. However, an optimization study specifically for ducted wind turbines (DWT’s) is missing or incomplete. This work focuses on a numerical

  14. Vacuum exhaust duct used for thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo; Kondo, Mitsuaki; Honda, Tsutomu.

    1990-01-01

    The present invention concerns a vacuum exhaust duct used for a thermonuclear device. A cylindrical metal liners is lined with a gap to the inside of a vacuum exhaust duct main body. Bellows are connected to both ends of the metal liners and the end of the bellows is welded to the vacuum exhaust duct main body. Futher, a heater is mounted to the metal liner on the side of the vacuum exhaust duct main body, and the metal liner is heated by the heater to conduct baking for the vacuum exhaust duct main body. Accordingly, since there is no requirement for elevating the temperature of the vacuum exhaust duct upon conducting baking, the vacuum exhaust duct scarcely suffers substantial deformation due to heat expansion. Further, there is also no substantial deformation for the bellows disposed between the outer circumference of the vacuum vessel and a portion of a vacuum exhaust duct, so that the durability of the bellows is greatly improved. (I.S.)

  15. Cholangiographic evaluation of bile duct carcinoma

    International Nuclear Information System (INIS)

    Nichols, D.A.; MacCarty, R.L.; Gaffey, T.A.

    1983-01-01

    Cholangiograms and clinical histories of 82 patients with biopsy-proved bile duct carcinoma were reviewed. The carcinomas were classified according to morphologic findings and clinical outcome. Ulcerative colitis and antecedent inflammatory disease of the biliary tree, particularly primary sclerosing cholangitis, seem to predispose to the development of bile duct carcinoma. Focal stenotic lesions were the most common morphologic type (62/82). Polypoid carcinomas and diffuse sclerosing carcinomas were less common and of about equal frequency. Prognosis was best for patients with polypoid carcinomas and worst for those with diffuse sclerosing carcinomas. In 69 cases (84%), the tumors involved the intrahepatic or proximal extrahepatic ducts, makin curative resection difficult or impossible. Patients with carcinomas limited to the more distal extrahepatic bile ducts had a longer average survival and a higher probability of surgical cure. Proper management of patients with bile duct carcinoma requires a complete and accurate cholangiographic evaluation of the morphology, location, and extent of the disease

  16. CoJet technology for oxygen injection injection in EAFS - industrial gases supply and customers productivity improvements; Tecnologia CoJet para injecao de oxigenio em FEAS - fornecimento de gases e aumento da produtividade dos clientes

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Izaias Lucas; Zagury, Pedro Athias [White Martins Gases Industriais Ltda., Rio de Janeiro, RJ (Brazil)

    2010-07-01

    PRAXAIR is one of the largest industrial gases producers of the World, being present in more than 40 countries and strongly connected to the steel industry. PRAXAIR has experience to supply products and services to all kinds of steel mills. Several technologies developed by the Company, such as CoJet (a system to coherent oxygen jet injection in EAF and BOF furnaces), Slag Splashing (splashing slag to cover BOF furnaces walls increasing refractory wear campaign life), AOD (a process for specialty steel production) and others, are currently in commercial operation in different parts of the world. In Brazil, Praxair is the owner of White Martins, the largest industrial gases company in South America, present in nine countries of the continent. Company's portfolio includes atmospheric gases, carbonic gas production, acetylene, hydrogen, specialty and health and care gases, mixtures for welding, gas seamless steel cylinders, applications equipment, and storage and gases transportation. The Company also operates a natural gas liquefaction unit. In addition to technologies and process, Praxair / White Martins can also supply solutions for measurement, control and gases injection, according to strict safety and quality standards. The present work has the objective to show the benefits of the CoJet EAF System, oxygen injectors positioned in the furnace walls. In 2009, two systems have been installed in South American mills and the results achieved will be following discussed. (author)

  17. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  18. Consequences of the technology survey and gap analysis on the EU DEMO R&D programme in tritium, matter injection and vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Day, Chr., E-mail: Christian.Day@kit.edu [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Butler, B. [Culham Science Centre (CCFE), Abingdon (United Kingdom); Giegerich, T. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Lang, P.T. [Max-Planck-Institute of Plasma Physics (IPP), Garching (Germany); Lawless, R. [Culham Science Centre (CCFE), Abingdon (United Kingdom); Meszaros, B. [EUROfusion Consortium, Programme Management Unit, Garching (Germany)

    2016-11-01

    Highlights: • The inner fuel cycle architecture of DEMO is developed in a systems engineering approach as a functional break-down diagram, driven by the need for inventory minimisation. • Technologies to fulfil the required functions are discussed and ranked. • Prime technologies are identified and an associated R&D programme is developed. • The core challenges of a DEMO fuel cycle beyond those already addressed in ITER are discussed. - Abstract: In the framework of the EUROfusion Programme, EU is preparing the conceptual design of the inner fuel cycle of a pulsed tokamak DEMO. This paper illustrates a quantified process to shape a R&D programme that exploits as much as possible previous R&D. In an initial step, the high-level requirements are collected and a novel DEMO inner fuel cycle architecture with its three sub-systems vacuum pumping, matter injection (fuelling and injection of plasma enhancement gases) and tritium systems (tritium plant and breeder coolant purification) is delineated, driven by the DEMO key challenge to reduce tritium inventory. Then, a technology survey is carried out to review potential existing solutions for the required process functions and to assess their maturity and risks. Finally, a decision-making scheme is applied to select the most promising candidates. ITER technology is exploited where possible. As a primary result, a fuel cycle architecture is suggested with an advanced tritium plant that avoids full isotope separation in the main loop and with a Direct Internal Recycling path in the vacuum systems to shorten cycle times. For core fuelling, classical inboard pellet injection technology is selected, in principle similar to that proposed for ITER but aiming for higher launch speeds to achieve deep fuelling of the DEMO plasma. Based on these findings, a tailored R&D programme is shaped that tackles the key questions until 2020.

  19. Bile Duct Adenoma with Oncocytic Features

    Directory of Open Access Journals (Sweden)

    E. J. Johannesen

    2014-01-01

    Full Text Available Bile duct adenomas are benign bile duct proliferations usually encountered as an incidental finding. Oncocytic bile duct neoplasms are rare and the majority are malignant. A 61-year-old male with a diagnosis of colorectal adenocarcinoma was undergoing surgery when a small white nodule was discovered on the surface of the right lobe of his liver. This lesion was composed of cytologically bland cells arranged in tightly packed glands. These cells were immunopositive for cytokeratin 7, negative for Hep Par 1, contained mucin, and had a Ki67 proliferation index of 8%. The morphology, immunophenotype, presence of mucin, and normal appearing bile ducts, as well as the increased Ki67 proliferation rate, were consistent with a bile duct adenoma with oxyphilic (oncocytic change. Oncocytic tumors in the liver are rare; the first described in 1992. Only two bile duct adenomas with oncocytic change have been reported and neither of them had reported mucin production or the presence of normal appearing bile ducts within the lesion.

  20. Financial Aspects of Bile Duct Injuries.

    Science.gov (United States)

    Palaz Alı, Ozgkıour; Ibis, Abdil Cem; Gurtekin, Basak

    2017-11-04

    BACKGROUND Major bile duct injury is the most worrisome complication of cholecystectomy. There is no detailed data about the incidence or treatment-related costs of bile duct injuries in Turkey. We aimed to determine prevalence and therapeutic costs of patients with major biliary duct injuries managed in our department, and further estimate a projection of these parameters at the national level. MATERIAL AND METHODS All patients admitted due to bile duct injury during cholecystectomy from 2011 to 2014 were included. Healthcare costs were calculated by summing of their all treatment-related costs in Istanbul Medical Faculty. We collected 2014-2015 data on number of patients diagnosed with cholecystitis in Turkey, the number of cholecystectomies, and the number of the interventions performed following these initial surgeries, which were obtained from the Turkish Social Security Institution. RESULTS Forty-nine patients were enrolled and bilioenteric diversion was performed in 39 patients: 20.4% of patients had Bismuth II, 38.8% had Bismuth III, and 40.8% had Bismuth IV biliary stricture. Comparison of stricture types with total costs, days of hospitalization, and outpatient clinic costs revealed significant differences. Mean total cost of corrective surgeries was 9199 TRY. We estimated that 1.5% to 2.4% of patients who underwent cholecystectomy in Turkey have bile duct injury (including 0.3% with major bile duct injury). CONCLUSIONS New preventive strategies should be used to avoid bile duct injuries, which have a huge financial impact on the national economy.

  1. Patient evaluation of the use of follitropin alfa in a prefilled ready-to-use injection pen in assisted reproductive technology: an observational study

    Directory of Open Access Journals (Sweden)

    Welcker J

    2010-09-01

    Full Text Available Abstract Background Self-administration of recombinant human follicle-stimulating hormone (r-hFSH can be performed using injection pen devices by women undergoing assisted reproductive technology procedures. The objective of this study was to explore the use of the prefilled follitropin alfa pen in routine assisted reproductive technology procedures in Germany. Methods This prospective, observational study was conducted across 43 German IVF centres over a period of 1.75 years. Patients who had used the prefilled follitropin alfa pen in the current or a previous cycle of controlled ovarian stimulation completed a questionnaire to assess their opinions of the device. Results A total of 5328 patients were included in the study. Of these, 2888 reported that they had previous experience of daily FSH injections. Significantly more patients reported that less training was required to use the prefilled follitropin alfa pen than a syringe and lyophilized powder (1997/3081 [64.8%]; p Conclusions In this questionnaire-based survey, routine use of the prefilled follitropin alfa pen was well accepted and associated with favourable patient perceptions. Users of the pen found it easier to initially learn how to use, and subsequently use, than other injection methods. In general, the prefilled follitropin alfa pen was the preferred method for self-administration of gonadotrophins. Together with previous findings, the results here indicate a high level of patient satisfaction among users of the prefilled follitropin alfa pen for daily self-administration of r-hFSH.

  2. [Salivary gland drainage into the thyroglossal duct].

    Science.gov (United States)

    Siem, G; Natvig, K; Kolbenstvedt, A; Lømo, J

    2001-01-20

    Failure in regression of the thyroglossal duct is one of the most common reasons for midline swellings in the neck. Several authors have described recurrent thyroglossal duct remnants with persisting draining sinuses. However, few have described accessory salivary glands that drain into the thyroglossal duct. In this article we report two such cases with midline salivary glands in the floor of the mouth. These two patients were subsequently successfully treated with radical tissue resection in the area between the hyoid bone and foramen cecum. Preoperative fistulography or sinography was useful to demonstrate the ductal ramification of the salivary glands, and use of methylene blue during surgery proved of significant value for the result.

  3. Optimized Matching Lift Unit Transmission Ratio of Engine Driven Ducted Fan

    Directory of Open Access Journals (Sweden)

    Xiao Senlin

    2018-01-01

    Full Text Available As a kind of VTOL technology, ducted fan is not only used by many kinds of aircrafts, but also one of the trends of the future aircraft lift system, and attracts more and more attention. For an engine driven ducted fan lift unit, involving the engine and ducted fan matching problem, the form of transmission and transmission ratio are the key design parameters. In order to design and develop a ducted fan aircraft reasonably, a thrust test platform was set up to connect the engine with the ducted fan through the belt driving. The matching relationship between the engine and the transmission system was experimentally studied and the optimal transmission ratio was determined. The results showed that the optimal transmission ratio for the engine 1 is 2.2:1, and for the engine 2, the optimal transmission ratio should be 2.95:1 based on the current ducted and movable blade aerofoil design. At this time, the lift will exceed 130 kg•f, meeting the aircraft's original design requirements.

  4. Algorithm of dynamic regulation of a system of duct, for a high accuracy climatic system

    Science.gov (United States)

    Arbatskiy, A. A.; Afonina, G. N.; Glazov, V. S.

    2017-11-01

    Currently, major part of climatic system, are stationary in projected mode only. At the same time, many modern industrial sites, require constant or periodical changes in technological process. That is 80% of the time, the industrial site is not require ventilation system in projected mode and high precision of climatic parameters must maintain. While that not constantly is in use for climatic systems, which use in parallel for different rooms, we will be have a problem for balance of duct system. For this problem, was created the algorithm for quantity regulation, with minimal changes. Dynamic duct system: Developed of parallel control system of air balance, with high precision of climatic parameters. The Algorithm provide a permanent pressure in main duct, in different a flow of air. Therefore, the ending devises air flow have only one parameter for regulation - flaps open area. Precision of regulation increase and the climatic system provide high precision for temperature and humidity (0,5C for temperature, 5% for relative humidity). Result: The research has been made in CFD-system - PHOENICS. Results for velocity of air in duct, for pressure of air in duct for different operation mode, has been obtained. Equation for air valves positions, with different parameters for climate in room’s, has been obtained. Energy saving potential for dynamic duct system, for different types of a rooms, has been calculated.

  5. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    Energy Technology Data Exchange (ETDEWEB)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A. [University of Pennsylvania Perelman School of Medicine, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Rambhatla, Siri J. [Beth Israel Medical Center, Department of Pediatrics, Newark, NJ (United States); Sreedharan, Ram R. [University of Pennsylvania, Departments of Gastroenterology, Hepatology and Nutrition, The Children' s Hospital of Philadelphia, Perelman School of Medicine, Philadelphia, PA (United States)

    2015-08-15

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  6. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    International Nuclear Information System (INIS)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A.; Rambhatla, Siri J.; Sreedharan, Ram R.

    2015-01-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  7. Transmission of wave energy in curved ducts

    Science.gov (United States)

    Rostafinski, W.

    1973-01-01

    A formation of wave energy flow was developed for motion in curved ducts. A parametric study over a range of frequencies determined the ability of circular bends to transmit energy for the case of perfectly rigid walls.

  8. Submandibular duct sialolithiasis an unusual presentation

    International Nuclear Information System (INIS)

    Shafi, M.; Jafferi, S.; Jafferi, S.

    2006-01-01

    Multiple calculi in a submandibular gland duct is an uncommon occurrence. One such case occurring in a young boy of 25 years is reported here where thirteen very small stones of 1-3 mm of maximum diameter were lined up in the Wharton's duct in such a way that they were difficult to appreciate on inspection and palpation. Successful exploration was done in two steps. (author)

  9. Hollow-duct radiation delivery system investigation

    Directory of Open Access Journals (Sweden)

    Kramer D.

    2013-05-01

    Full Text Available Investigation of hollow-duct structure for high-power laser-diode-array radiation delivery into the end-pumped large-aperture gain media is reported. A ray tracing method has been used to evaluate the performance of the structure designed for maximum transmission efficiency and output beam profile homogeneity. Variable hollow-duct lengths as well as emanating angles of laser-diode-array have been taken into account.

  10. Environmental Technology Verification: Supplement to Test/QA Plan for Biological and Aerosol Testing of General Ventilation Air Cleaners; Bioaerosol Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Air Cleaners

    Science.gov (United States)

    The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...

  11. A Comparison of Simulation Capabilities for Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Smith, Matt K [ORNL; Gu, Lixing [Florida Solar Energy Center (FSEC); New, Joshua Ryan [ORNL

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  12. Develop of ceramic effects: surface finishes, through digital inject technology; Desarrollo de efectos ceramicos como acabados superficiales, mediante tecnologia de inyeccion digital

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Ferro Spain SA has tackled the practical viability of tile surfaces decoration by means of applying layers of reduced thickness by means of the use of digital injection technology by ink jet and, specifically, relating to effects and superficial finishes different from colouring. It has been studied several mechanisms which allow to get those effects and the influence of the main variables. It has also been assessed the obtained results dealing with the current regulations as in the case of non-slip effect. (Author)

  13. Uptake and Acceptability of Information and Communication Technology in a Community-Based Cohort of People Who Inject Drugs: Implications for Mobile Health Interventions.

    Science.gov (United States)

    Genz, Andrew; Kirk, Gregory; Piggott, Damani; Mehta, Shruti H; Linas, Beth S; Westergaard, Ryan P

    2015-06-25

    Mobile phone and Internet-based technologies are increasingly used to disseminate health information and facilitate delivery of medical care. While these strategies hold promise for reducing barriers to care for medically-underserved populations, their acceptability among marginalized populations such as people who inject drugs is not well-understood. To understand patterns of mobile phone ownership, Internet use and willingness to receive health information via mobile devices among people who inject drugs. We surveyed current and former drug injectors participating in a longitudinal cohort study in Baltimore, Maryland, USA. Respondents completed a 12-item, interviewer-administered questionnaire during a regular semi-annual study visit that assessed their use of mobile technology and preferred modalities of receiving health information. Using data from the parent study, we used logistic regression to evaluate associations among participants' demographic and clinical characteristics and their mobile phone and Internet use. The survey was completed by 845 individuals, who had a median age of 51 years. The sample was 89% African-American, 65% male, and 33% HIV-positive. Participants were generally of low education and income levels. Fewer than half of respondents (40%) indicated they had ever used the Internet. Mobile phones were used by 86% of respondents. Among mobile phone owners, 46% had used their phone for text messaging and 25% had accessed the Internet on their phone. A minority of respondents (42%) indicated they would be interested in receiving health information via phone or Internet. Of those receptive to receiving health information, a mobile phone call was the most favored modality (66%) followed by text messaging (58%) and Internet (51%). Utilization of information and communication technology among this cohort of people who inject drugs was reported at a lower level than what has been estimated for the general U.S. Our findings identify a potential

  14. TARA beamline and injection system

    International Nuclear Information System (INIS)

    Post, R.S.; Brindza, P.; Coleman, J.W.; Torti, R.P.; Blackfield, D.T.; Goodrich, P.

    1983-01-01

    The TARA beamline for neutral beam injection will permit one to three sources to fire into each plug (60 degree or optional 90 degree injection with respect to the TARA axis) or into each anchor (90 degree injection only). The sources, pre-aimed on their mounting plate at the NB test stand, may be fired into neutralizer ducts or optionally through a magnesium curtain, and the unneutralized fraction is dumped by the TARA fringing field onto a receiver plate. The beamline is housed in a cylindrical tank with the beam axis along the tank diameter at the midplane. The tank will be sorption pumped using LN + T/sub I/ or N/sub B/ and/or e-beam gettering. The beam burial tank contains sed arrays and a thin foil dump which reaches sufficiently high temperatures during the shot to boil out gas between shots

  15. Development of bus duct inspection robot at nuclear power plant

    International Nuclear Information System (INIS)

    Hamada, Mamoru; Hoshi, Teruaki; Komura, Yoshinari

    2017-01-01

    Under the present situation, nuclear power plant has some places which are inspected with difficulty or not inspected due to narrowness or physical restriction, when carrying out periodical inspection. The subject of our research and development is to improve the accuracy of inspection and also to save labor (liberation from distress work of the worker) by applying a robot technology to the periodical inspection of the nuclear power plant. As a specific example, we report that developed robot can inspect inside the narrow space of Isolated Phase Bus ducts, which connect between a turbine generator and the main transformer. (author)

  16. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  17. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  18. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  19. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  20. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  1. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  2. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  3. Ultrasound appearance of chronic mammary duct ectasia

    Energy Technology Data Exchange (ETDEWEB)

    Duchesne, N. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)]. E-mail: nathalie_duchesne_22@yahoo.ca; Skolnik, S. [Univ. of Toronto, Dept. of Family Medicine, Toronto, Ontario (Canada); Bilmer, S. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)

    2005-12-15

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  4. Ultrasound appearance of chronic mammary duct ectasia

    International Nuclear Information System (INIS)

    Duchesne, N.; Skolnik, S.; Bilmer, S.

    2005-01-01

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  5. A radiographic study of nasopalatine duct cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1993-02-15

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  6. A radiographic study of nasopalatine duct cysts

    International Nuclear Information System (INIS)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae

    1993-01-01

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  7. Low Speed Technology for Small Turbine Development Reaction Injection Molded 7.5 Meter Wind Turbine Blade

    Energy Technology Data Exchange (ETDEWEB)

    David M. Wright; DOE Project Officer - Keith Bennett

    2007-07-31

    An optimized small turbine blade (7.5m radius) was designed and a partial section molded with the RIM (reaction-injection molded polymer) process for mass production. The intended market is for generic three-bladed wind turbines, 100 kilowatts or less, for grid-assist end users with rural and semi-rural sites, such as the farm/ranch market, having low to moderate IEC Class 3-4 wind regimes. This blade will have substantial performance improvements over, and be cheaper than, present-day 7.5m blades. This is made possible by the injection-molding process, which yields high repeatability, accurate geometry and weights, and low cost in production quantities. No wind turbine blade in the 7.5m or greater size has used this process. The blade design chosen uses a RIM skin bonded to a braided infused carbon fiber/epoxy spar. This approach is attractive to present users of wind turbine blades in the 5-10m sizes. These include rebladeing California wind farms, refurbishing used turbines for the Midwest farm market, and other manufacturers introducing new turbines in this size range.

  8. The "flying" bile duct: avulsion of the common bile duct in a plane crash survivor.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Blunt trauma is an unusual cause of extrahepatic bile duct injury. This is a case of a 51-year-old gentleman who sustained a significant seatbelt injury in a plane crash. Laparotomy, performed due to persistent abdominal pain, revealed that the common bile duct (CBD) was completely avulsed from the duodenum. Following insertion of drains and transfer to a hepatobiliary centre, the devascularised CBD was excised and replaced with a roux-en-y hepaticojejunostomy. Necrotic tissue was debrided from the pancreatic head. A persistent bile leak developed from the sub-hepatic drain. Repeat laparotomy revealed a bile leak from small ducts on the liver surface. Ligation of the ducts and bioglue sealing of the area were successfully performed. Subsequent to this a pancreatic fistula developed from the main pancreatic duct, which has since resolved. This unusual case illustrates the need for prompt recognition and early repair to optimise outcomes in traumatic CBD injury.

  9. ITER L 6 equatorial maintenance duct remote handling study

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The status and conclusions of a preliminary study of equatorial maintenance duct remote handling is reported. Due to issues with the original duct design a significant portion of the study had to be refocused on equatorial duct layout studies. The study gives an overview of some of the options for design of these ducts and the impact of the design on the equipment to work in the duct. To develop a remote handling concept for creating access through the ducts the following design tasks should be performed: define the operations sequences for equatorial maintenance duct opening and closing; review the remote handling requirements for equatorial maintenance duct opening and closing; design concept for door and pipe handling equipment and to propose preliminary procedures for material handling outsides the duct. 35 figs

  10. Squamous metaplasia of lactiferous ducts (SMOLD)

    International Nuclear Information System (INIS)

    Lo, G.; Dessauvagie, B.; Sterrett, G.; Bourke, A.G.

    2012-01-01

    The aim of this review is to illustrate the mammographic and sonographic appearances of squamous metaplasia of the lactiferous ducts (SMOLD) and to discuss the disease processes of this uncommon breast disease, which shows a strong correlation with smoking. The most common mammographic appearance is of a retro-areolar asymmetrical density. Ultrasonography of the symptomatic breast typically shows a retro-areolar, predominately medial, ill-defined, hypoechoic lesion with either abscess or sinus/fistula formation. Duct dilatation and continuity with lactiferous ducts is commonly seen. Increased vascularity is occasionally seen on colour Doppler ultrasound. Pathology tissue confirmation is always required and this can be by histology of a core biopsy or excision specimen, or fine-needle aspiration (FNA) cytology. Occasionally smears of an associated abundant nipple or sinus discharge may be of value.

  11. Salivary duct carcinoma: a Danish national study

    DEFF Research Database (Denmark)

    Breinholt, Helle; Elhakim, Mohammad Talal; Godballe, Christian

    2016-01-01

    BACKGROUND: To present the first national series of salivary duct carcinoma patients, including survival rates and an analysis of prognostic factors. METHODS: By merging three Danish nationwide registries that encompass an entire population, 34 patients diagnosed with salivary duct carcinoma from......-rank test. RESULTS: Salivary duct carcinoma showed an incidence of 0.04/100.000 inhabitants/year. Distant recurrence was seen in 52% of patients. Five-year overall survival, disease-specific survival and recurrence-free survival were 32%, 42% and 35%, respectively. Univariate analyses suggested that overall...... carcinoma incidence averages to two episodes per year in the entire Kingdom of Denmark. With half of patients in this study experiencing distant recurrences and only a third surviving at 5 years, prognosis is dismal. Advanced overall stage, vascular invasion and involved resection margins all seem...

  12. Separation of Hepatic parenchymal and Intrahepatic bile duct isotope activity: Studies of parenchymal function and bile duct flow using dynamic Tc-99m HIDA SPECT

    International Nuclear Information System (INIS)

    Jonas, E.; Naslund, E.; Freedman, J.; Hultcrantz, R.; Slezak, P.; Jacobsson, H.

    2003-01-01

    Currently used liver function tests have several shortcomings. Most of them are either insensitive or non-specific. The ultimate liver function test is probably a dynamic study, using a test substance with exclusive hepatic elimination and bile excretion, detected by means of a non?invasive method enabling sampling from all relevant compartments. In this paper we describe a method which enables measurements of parenchymal function and bile flow in different liver segments. The study was performed on 20 healthy volunteers. Tc-99m HIDA was used as test substrate and repeated Single Photon Emission Computed Tomography (SPECT) registrations as sampling method. Following injection of 120 MBq of Tc-99m HIDA, twelve liver SPECT examinations were performed at 6-minute intervals. Duct-representing peaks on images were detected by cranio-caudal activity scanning. Sampling from parenchyma and bile ducts in liver segments 2 to 8 was performed on consecutive examinations, creating time-activity graphs for parenchyma and ducts. Quantitative analysis of parenchymal and duct curves was performed and the results obtained from the left and right-sided liver segments were compared. Maximum counts/voxel (C max ) of left-sided segments (mean=33.2) were significantly lower than the values from right-sided segments (mean=24.7) and flow of isotope from parenchyma to bile ducts was significantly slower on the left. Furthermore, bile flow in ducts draining left-sided segments was slower than flow on the right side as reflected in significantly longer excretion t 1/2 (28.9 compared to 25.2 minutes) and delayed t max . (21.7 compared to 17.0 minutes). It has been concluded that the new method could provide a differential analysis of tracer flow in the hepatic parenchyma and the bile ducts. This pilot study on normal subjects has revealed interesting differences in both parenchymal accumulation as well as biliary excretion between left and right-sided segments. However, the value of the method

  13. Evaluation of PEGIT duct connection system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Brenner, Douglas E.; Sherman, Max H.; Dickerhoff, Darryl J.

    2003-08-01

    Most air duct system components are assembled in the field and are mechanically fastened by sheet metal screws (for sheet metal-to-sheet metal) or by drawbands (for flex duct-to-sheet metal). Air sealing is separate from this mechanical fastening and is usually achieved using tape or mastic products after mechanical fastening. Field observations have shown that mechanical fastening rarely meets code or manufacturers requirements and that sealing procedures are similarly inconsistent. To address these problems, Proctor Engineering Group (PEG) is developing a system of joining ducts (called PEGIT) that combines the mechanical fastening and sealing into a single self-contained procedure. The PEGIT system uses a shaped flexible seal between specially designed sheet metal duct fittings to both seal and fasten duct sections together. Figure 1 shows the inner duct fitting complete with rubber seal. This seal provides the air seal for the completed fitting and is shaped to allow the inner and outer fittings to slide together, and then to lock the fittings in place. The illustration in Figure 2 shows the approximate cross section of the rubber seal that shows how the seal has a lip that is angled backwards. This angled lip allows the joint to be pushed together by folding flat but then its long axis makes it stiff in the pulling apart direction. This study was undertaken to assist PEG in some of the design aspects of this system and to test the performance of the PEGIT system. This study was carried out in three phases. The initial phase evaluated the performance of a preliminary seal design for the PEGIT system. After the first phase, the seal was redesigned and this new seal was evaluated in the second phase of testing. The third phase performed more detailed testing of the second seal design to optimize the production tolerances of the sheet metal fittings. This report summarizes our findings from the first two phases and provides details about the third phase of testing.

  14. Percutaneous treatment of benign bile duct strictures

    Energy Technology Data Exchange (ETDEWEB)

    Koecher, Martin [Department of Radiology, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic)]. E-mail: martin.kocher@seznam.cz; Cerna, Marie [Department of Radiology, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Havlik, Roman [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Kral, Vladimir [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Gryga, Adolf [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Duda, Miloslav [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic)

    2007-05-15

    Purpose: To evaluate long-term results of treatment of benign bile duct strictures. Materials and methods: From February 1994 to November 2005, 21 patients (9 men, 12 women) with median age of 50.6 years (range 27-77 years) were indicated to percutaneous treatment of benign bile duct stricture. Stricture of hepatic ducts junction resulting from thermic injury during laparoscopic cholecystectomy was indication for treatment in one patient, stricture of hepaticojejunostomy was indication for treatment in all other patients. Clinical symptoms (obstructive jaundice, anicteric cholestasis, cholangitis or biliary cirrhosis) have appeared from 3 months to 12 years after surgery. Results: Initial internal/external biliary drainage was successful in 20 patients out of 21. These 20 patients after successful initial drainage were treated by balloon dilatation and long-term internal/external drainage. Sixteen patients were symptoms free during the follow-up. The relapse of clinical symptoms has appeared in four patients 9, 12, 14 and 24 months after treatment. One year primary clinical success rate of treatment for benign bile duct stricture was 94%. Additional two patients are symptoms free after redilatation (15 and 45 months). One patient is still in treatment, one patient died during secondary treatment period without interrelation with biliary intervention. The secondary clinical success rate is 100%. Conclusion: Benign bile duct strictures of hepatic ducts junction or biliary-enteric anastomosis are difficult to treat surgically and endoscopically inaccessible. Percutaneous treatment by balloon dilatation and long-term internal/external drainage is feasible in the majority of these patients. It is minimally invasive, safe and effective.

  15. Fluid flow in a spiral microfluidic duct

    Science.gov (United States)

    Harding, Brendan; Stokes, Yvonne

    2018-04-01

    We consider the steady, pressure driven flow of a viscous fluid through a microfluidic device having the geometry of a planar spiral duct with a slowly varying curvature and height smaller than width. For this problem, it is convenient to express the Navier-Stokes equations in terms of a non-orthogonal coordinate system. Then, after applying appropriate scalings, the leading order equations admit a relatively simple solution in the central region of the duct cross section. First-order corrections with respect to the duct curvature and aspect ratio parameters are also obtained for this region. Additional correction terms are needed to ensure that no slip and no penetration conditions are satisfied on the side walls. Our solutions allow for a top wall shape that varies with respect to the radial coordinate which allows us to study the flow in a variety of cross-sectional shapes, including trapezoidal-shaped ducts that have been studied experimentally. At leading order, the flow is found to depend on the local height and slope of the top wall within the central region. The solutions are compared with numerical approximations of a classical Dean flow and are found to be in good agreement for a small duct aspect ratio and a slowly varying and small curvature. We conclude that the slowly varying curvature typical of spiral microfluidic devices has a negligible impact on the flow in the sense that locally the flow does not differ significantly from the classical Dean flow through a duct having the same curvature.

  16. The Canadian residential duct and chimney survey

    Energy Technology Data Exchange (ETDEWEB)

    Fugler, D.

    2003-12-01

    A study was conducted in 1989 to better understand the thermal performance of ducts and chimneys in houses. The objective was to address the problems associated with insufficient airflow and backdrafting of combustion gases resulting from malfunctioning fans, furnaces and fireplaces. The Duct Test Rig was used to measure and recorded airflows and heat losses in a variety of ducts and chimneys in a representative mix of houses in Vancouver, Kelowna, Winnipeg, Calgary, Toronto, London, Montreal, Quebec City, Halifax, Fredericton and Ottawa. Bath, kitchen, clothes dryer and central vacuum exhaust fans were tested to determine how performance is affected by fan age, accumulations of dust, grease, bugs and installation methods. Results indicate that there is no statistical difference between axial or centrifugal fans. The greatest problem appeared to be with low flows, high leakage rates, and poor conditions of bathroom fans. Many kitchen fans were found to be blocked at the inlet by cooking grease. The exhaust flows depended greatly on the condition of the backdraft damper. Dryer exhaust airflow was typically less than the 75 L/s specified by manufacturers, but even old dryers performed relatively well. All types of chimneys were tested for different positive hood pressures, airflow lost through leakage, and thermal characteristics. Airflow was found to vary depending on the type and area of the flue and the presence of a cap. For heating systems, the low duct efficiency was due mostly to duct leakage, radiation losses and restrictive ducts and registers. The findings of this testing program are still valid today. 3 tabs.

  17. Bundle duct interaction studies for fuel assemblies

    International Nuclear Information System (INIS)

    Hsia, H.T.S.; Kaplan, S.

    1981-06-01

    It is known that the wire-wrapped rods and duct in an LMFBR are undergoing a gradual structural distortion from the initially uniform geometry under the combined effects of thermal expansion and irradiation induced swelling and creep. These deformations have a significant effect on flow characteristics, thus causing changes in thermal behavior such as cladding temperature and temperature distribution within a bundle. The temperature distribution may further enhance or retard irradiation induced deformation of the bundle. This report summarizes the results of the continuing effort in investigating the bundle-duct interaction, focusing on the need for the large development plant

  18. Acoustic power balance in lined ducts

    Science.gov (United States)

    Eversman, W.

    1979-01-01

    It is shown that the two common definitions of acoustic energy density and intensity in uniform unlined ducts carrying uniform flow are compatible to the extent that both energy densities can be used in an appropriate variational principle to derive the convected wave equation. When the duct walls are lined both energy densities must be modified to account for the wall energy density. This results in a new energy conservation equation which utilizes a modified definition of axial power and accounts for wall dissipation. Computations in specific cases demonstrate the validity of the modified acoustic energy relation.

  19. Green technology effect of injection pressure, timing and compression ratio in constant pressure heat addition cycle by an eco-friendly material.

    Science.gov (United States)

    Karthikayan, S; Sankaranarayanan, G; Karthikeyan, R

    2015-11-01

    Present energy strategies focus on environmental issues, especially environmental pollution prevention and control by eco-friendly green technologies. This includes, increase in the energy supplies, encouraging cleaner and more efficient energy management, addressing air pollution, greenhouse effect, global warming, and climate change. Biofuels provide the panorama of new fiscal opportunities for people in rural area for meeting their need and also the demand of the local market. Biofuels concern protection of the environment and job creation. Renewable energy sources are self-reliance resources, have the potential in energy management with less emissions of air pollutants. Biofuels are expected to reduce dependability on imported crude oil with connected economic susceptibility, reduce greenhouse gases, other pollutants and invigorate the economy by increasing demand and prices for agricultural products. The use of neat paradise tree oil and induction of eco-friendly material Hydrogen through inlet manifold in a constant pressure heat addition cycle engine (diesel engine) with optimized engine operating parameters such as injection timing, injection pressure and compression ratio. The results shows the heat utilization efficiency for neat vegetable oil is 29% and neat oil with 15% Hydrogen as 33%. The exhaust gas temperature (EGT) for 15% of H2 share as 450°C at full load and the heat release of 80J/deg. crank angle for 15% Hydrogen energy share. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. CASE REPORTS Thyroglossal duct cyst in adult Nigerians: a report ...

    African Journals Online (AJOL)

    MacBook

    Thyroglossal duct cyst (TGDC) is the most common paediatric midline neck lesion. It is rare ... modified Sistrunk's operation and histology confirmed the diagnosis of thyroglossal cyst. ... surgical procedure for the treatment of thyroglossal duct ...

  1. Liver and Bile Duct Cancer—Health Professional Version

    Science.gov (United States)

    Liver cancer includes two major types: hepatocellular carcinoma (HCC) and intrahepatic bile duct cancer, also known as cholangiocarcinoma. Find evidence-based information on liver and bile duct cancer treatment, causes and prevention, screening, research, genomics and statistics.

  2. New concept of the buildup factor in bent ducts

    International Nuclear Information System (INIS)

    Faik Ouahab, Z.; Jehouani, A.; Groetz, J.-E.

    2011-01-01

    A major problem confronting the radiation shielding designer is the accurate determination of neutron streaming through various penetrations in walls, ducts and mazes. The previous studies on neutron transmission were performed through empty ducts. The aim of this work is to evaluate the neutron transmission probability through a filled bent duct and the proposition of a new concept of the buildup factor for neutrons in multilegged ducts. An angular biaising technique is used in the Monte Carlo simulations to accelerate the calculation convergence. Results are first compared with those obtained by the MCNPX code. For an empty bent duct, the neutron transmission is only due to the neutron reflection on the duct wall. For a filled duct, the major contribution is due to the scattering on the atoms filling the duct.

  3. Vitamin K1 attenuates bile duct ligation-induced liver fibrosis in rats.

    Science.gov (United States)

    Jiao, Kun; Sun, Quan; Chen, Baian; Li, Shengli; Lu, Jing

    2014-06-01

    Vitamin K1 is used as a liver protection drug for cholestasis-induced liver fibrosis in China, but the mechanism of vitamin K1's action in liver fibrosis is unclear. In this study, a model of liver fibrosis was achieved via bile duct ligation in rats. The rats were then injected with vitamin K1, and the levels of serum aspartate aminotransferase, alanine transaminase, total bilirubin and the fibrotic grade score, collagen content, the expressions of α-smooth muscle actin (SMA) and cytokeratin 19 (CK19) were measured on day 28 after ligation. The levels of the biochemical parameters, fibrotic score and collagen content were significantly reduced by treatment with vitamin K1 in bile duct-ligated rats. In addition, α-SMA and CK19 expression was significantly reduced by vitamin K1 treatment in bile duct-ligated rats. These results suggested that vitamin K1 may attenuate liver fibrosis by inhibiting hepatic stellate cell activation in bile duct-ligated rats.

  4. Melatonin attenuates oxidative stress, liver damage and hepatocyte apoptosis after bile-duct ligation in rats.

    Science.gov (United States)

    Aktas, Cevat; Kanter, Mehmet; Erboga, Mustafa; Mete, Rafet; Oran, Mustafa

    2014-10-01

    The goal of this study was to evaluate the possible protective effects of melatonin against cholestatic oxidative stress, liver damage and hepatocyte apoptosis in the common rats with bile duct ligation (BDL). A total of 24 male Wistar albino rats were divided into three groups: control, BDL and BDL + received melatonin; each group contains eight animals. Melatonin-treated BDL rats received daily melatonin 100 mg/kg/day via intraperitoneal injection. The application of BDL clearly increased the malondialdehyde (MDA) levels and decreased the superoxide dismutase (SOD) and glutathione (GSH) activities. Melatonin treatment significantly decreased the elevated tissue MDA levels and increased the reduced SOD and GSH enzyme levels in the tissues. The changes demonstrate that the bile duct proliferation and fibrosis in expanded portal tracts include the extension of proliferated bile ducts into lobules, mononuclear cells and neutrophil infiltration into the widened portal areas as observed in the BDL group. The data indicate that melatonin attenuates BDL-induced cholestatic liver injury, bile duct proliferation and fibrosis. The α-smooth muscle actin (α-SMA) and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL)-positive cells in the BDL were observed to be reduced with the melatonin treatment. These results suggest that administration of melatonin is a potentially beneficial agent to reduce liver damage in BDL by decreasing oxidative stress. © The Author(s) 2012.

  5. A K-Band Low-Power Phase Shifter Based on Injection Locked Oscillator in 0.13 μm CMOS Technology

    Science.gov (United States)

    Qiu, Qi-Lin; Yu, Xiao-Peng; Sui, Wen-Quan

    2017-11-01

    In this paper, the design challenges of the injection-locked oscillator (ILO)-based phase shifter are reviewed and analyzed. The key design considerations such as the operating frequency, locking range, and linearity of the phase shifters are analysed in detail. It is possible to optimize the phase shifter in certain parameters such as ultra-low power while meeting the requirements of a certain system. As a design example, a K-band phase shifter is implemented using a commercial 0.13 μm CMOS technology, where a conventional LC tank based topology is implemented but optimised with a good balance among power consumption, working range, sensitivity, and silicon area, etc. Measurement results show that the proposed phase shift is able to work at 22-23.4 GHz with a range of 180∘ while consuming 3.14 mW from a 1.2 V supply voltage.

  6. Kinetic studies of sea mango (Cerbera odollam) oil for biodiesel production via injection of superheated methanol vapour technology

    International Nuclear Information System (INIS)

    Ang, Gaik Tin; Tan, Kok Tat; Lee, Keat Teong; Mohamed, Abdul Rahman

    2015-01-01

    Highlights: • Sea mango oil with high FFA was directly used to produce biodiesel. • Non-catalytic superheated methanol transesterification system is developed. • High content of FAME can be obtained. • Kinetic modelling based on reaction mechanism is proposed and verified. • Kinetic study for reversible transesterification and esterification reactions. - Abstract: In this study, sea mango (Cerbera odollam) oil which is rich in free fatty acid was utilised as the feedstock in one-step superheated methanol vapour (SMV) transesterification reaction without going through pre-treatment step. SMV transesterification reaction was initiated by injecting superheated methanol vapour into sea mango oil phase. Effect of methanol flow rate at the range of 1–4 mL/min as well as effect of reaction temperatures at the range of 260–290 °C was studied based on FAME production rates at constant initial oil volume of 100 mL. Kinetic modelling of semi-batch system, incorporating second-order of three-stepwise reversible transesterification of triglycerides (TG) and second order of reversible esterification of free fatty acid (FFA) were verified simultaneously using ordinary differential equation (ODE45) solver. It shows that transesterification reaction of TG and esterification of FFA would occur simultaneously. The high activation energy of 50 kJ/mol and low reaction rate constant of 1.62 × 10"−"4 dm"3/mol min verified that the reaction of TG to become diglycerides (DG) as the rate limiting step in this semi-batch SMV system.

  7. Data analysis of ship ventilation ducts based on CATIA V6

    Directory of Open Access Journals (Sweden)

    LU Yongjin

    2017-03-01

    Full Text Available In order to research on CATIA V6 ship duct design and related data,combined with a practical engineering background,a three-dimensional design method for the CATIA V6 ventilation system is exhibited,and the catalog composition of duct fittings and duct lofting process are presented. Meanwhile, revolving around the system design modules,the module processing objects and data storage location are analyzed in order to determine the object of study. And on this basis,the definition and specific content of the engineering technological tables are illustrated in detail;specifically,the contents are extended. Moreover,in light of the three-dimensional model,further research into the underlying data structure of ventilation ducts is implemented. The relationships between the major technological tables are shown. The results of the study are not only beneficial for designers to grasp design technology,but also essential for software developers to secure theoretical guidance and technical support.

  8. Solitary intrahepatic bile-duct cyst presenting with Jaundice

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Chun, Ki Sung; Ha, Hyun Kwon; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Jun Gi

    1989-01-01

    Caroli's disease is an uncommon condition, and characterized by congenital segmental saccular dilatation of intrahepatic bile ducts. A case of Caroli's disease, manifested by only a large communicating cystic dilatation of left intrahepatic bile duct and causing extrinsic pressure over the extrahepatic bile duct, is presented. The patient was 43-year-old housewife, hospitalized because of abdominal distension and severe jaundice. To relieve jaundice and alleviate surgical intervention, percutaneous drainage of the bile-duct cyst preceded surgery

  9. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  10. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  11. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  12. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  13. Persistent Mullerian Duct Syndrome (PMDS With Large Intraabdominal Seminoma

    Directory of Open Access Journals (Sweden)

    Della Harigovind

    2017-07-01

    Full Text Available Persistent Mullerian Duct Syndrome, a form of male pseudohermaphroditism is characterized by the presence of the Mullerian duct derivatives in an otherwise phenotypically as well as genotypically normal male. We report a case of large intra abdominal seminoma in a male patient with cryptorchidism, along with persistence of Mullerian duct derivatives (uterus.

  14. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Razman Jarmin

    2004-10-01

    Full Text Available A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  15. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    OpenAIRE

    Razman Jarmin; Shaharin Shaharuddin

    2004-01-01

    A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  16. Iatrogenic injury of an aberrant right posterior sectoral bile duct

    African Journals Online (AJOL)

    (Figs 1 and 2). A week later, an endoscopic retrograde cholangiopancreatography. (ERCP) examination was performed. This showed no filling of the right posterior sectoral ducts but normal opacification of the other ducts. (Figs 3a and b). These findings led to the diagnosis of an aberrant right posterior sectoral bile duct that ...

  17. A case of fascioliasis in common bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-10-15

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct.

  18. A case of fascioliasis in common bile duct

    International Nuclear Information System (INIS)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong

    1989-01-01

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct

  19. Internal radiotherapy for hilar bile duct cancer

    International Nuclear Information System (INIS)

    Ryu, Munemasa; Ogino, Takashi; Konishi, Hiroshi

    1999-01-01

    By December 1998, 24 patients with non-resected hilar bile duct cancer (mean age of 74) had received bile duct intracavitary irradiation and 13 patients with residual cancer after resection of hilar bile duct cancer had received postoperative intracavitary irradiation. After they were externally irradiated 30 Gy in total by 15 fractions (2 Gy/time, 5 times in a week), intracavitary irradiation using 192-Ir was given 5 times in total (2 times in a week) from 3 weeks after external irradiation under the condition which dose became 8 Gy in depth of 10 mm from radiation source. The cases of postoperative irradiation had 3 times in total. As for 20 patients of non-resected hilar bile duct cancer without metastasis, 50% survival time was 265 days and there was no 5 year survivor. Fifty percents survival time of 4 patients with metastasis was 113 days. The effect of local control was recognized in 20 patients (83.3%). In 13 patients of postoperative irradiation, 50% survival time was 554 days, and survival rate of 3 years was 28%. (K.H.)

  20. 46 CFR 116.610 - Ventilation ducts.

    Science.gov (United States)

    2010-10-01

    ... incidental to its installation, must be made of noncombustible material. (c) Combustibles and other foreign materials are not allowed within ventilation ducts. However, metal piping and electrical wiring installed in... the wiring does not interfere with the operation of fire dampers. Electrical wiring and piping may not...

  1. Calcium influx pathways in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Hug, M J; Pahl, C; Novak, I

    1996-01-01

    A number of agonists increase intracellular Ca2+ activity, [Ca2+]i, in pancreatic ducts, but the influx/efflux pathways and intracellular Ca2+ stores in this epithelium are unknown. The aim of the present study was to characterise the Ca2+ influx pathways, especially their pH sensitivity, in nati...

  2. MR findings in thyroglossal duct cysts

    International Nuclear Information System (INIS)

    Blandino, A.; Salvi, L.; Chirico, G.; Scribano, E.; Longo, M.; Pandolfo, I.

    1990-01-01

    Two patients with thyroglossal duct cysts have been studied with CT and MR. The typical CT feature of these cystic upper-neck lesions are depicted in literature, conversely MR findings are not well known. The homogeneous high intensity on T1-weighted images, higher than simple cyst or fluid, is the most typical feature of the thyroglossal cyst. (author). 12 refs.; 5 figs

  3. [Bile duct lesions in laparoscopic cholecystectomy].

    Science.gov (United States)

    Siewert, J R; Ungeheuer, A; Feussner, H

    1994-09-01

    Laparoscopic cholecystectomy is both resulting in a slightly higher incidence of biliary lesions and a change of prevalence of the type of lesions. Damage to the biliary system occurs in 4 different types: The most severe case is the lesion with a structural defect of the hepatic or common bile duct with (IVa) or without (IVb) vascular injury. Tangential lesions without structural loss of the duct should be denominated as type III (IIIa with additional lesion to the vessels, type IIIb without). Type II comprehends late strictures without obvious intraoperative trauma to the duct. Type I includes immediate biliary fistulae of usually good prognosis. The increasing prevalence of structural defects of the bile ducts appears to be a peculiarity of laparoscopic cholecystectomy necessitating highly demanding operative repair. In the majority of cases, hepatico-jejunostomy or even intraparenchymatous anastomoses are required. Adaptation of well proven principles of open surgery is the best prevention of biliary lesions in laparoscopic cholecystectomy as well as the readiness to convert early to the open procedure.

  4. Depressurization test on hot gas duct

    International Nuclear Information System (INIS)

    Tanihira, Masanori; Kunitomi; Kazuhiko; Inagaki, Yoshiyuki; Miyamoto, Yoshiaki; Sato, Yutaka.

    1989-05-01

    To study the integrity of internal structures and the characteristics in a hot gas duct under the rapid depressurization accident, depressurization tests have been carried out using a test apparatus installed the hot gas duct with the same size and the same structures as that of the High Temperature Engineering Test Reactor (HTTR). The tests have been performed with three parameters: depressurization rate (0.14-3.08 MPa/s) determined by orifice diameter, area of the open space at the slide joint (11.9-2036 mm 2 ), and initial pressure (1.0-4.0 MPa) filled up in a pressure vessel, by using nitrogen gas and helium gas. The maximum pressure difference applied on the internal structures of the hot gas duct was 2.69 MPa on the liner tube and 0.45 MPa on the separating plate. After all tests were completed, the hot gas duct which was used in the tests was disassembled. Inspection revealed that there were no failure and no deformation on the internal structures such as separating plates, insulation layers, a liner tube and a pressure tube. (author)

  5. Whistler instability in a magnetospheric duct

    International Nuclear Information System (INIS)

    Talukdar, I.; Tripathi, V.K.; Jain, V.K.

    1989-01-01

    A whistler wave propagating through a preformed magnetospheric duct is susceptible to growth/amplification by an electron beam. The interaction is non-local and could be of Cerenkov or slow-cyclotron type. First-order perturbation theory is employed to obtain the growth rate for flat and Gaussian beam densities. (author)

  6. Study and modeling of the reduction of sulfur dioxide, nitrogen oxides and hydrogen chloride by dry injection technologies

    Energy Technology Data Exchange (ETDEWEB)

    Wang Wuyin

    1997-05-01

    The potential and mechanism to reduce acid gases, such as sulfur dioxide (SO{sub 2}), nitrogen oxides (NO{sub x}) and hydrogen chloride (HCl), by dry Ca-based sorbents have been studied to improve the efficiency of the process and sorbent utilization. Several natural limestones were tested for SO{sub 2} removal. Calcium conversion as high as 45 % was achieved in the first 0.3 s at 1000 deg C, 1000 ppm SO{sub 2} and Ca/S=1. A SO{sub 2} removal efficiency of 95 % was reached at Ca/S=2. Two models for estimating the sulfation of CaO at high temperature are presented. Short-residence-time sulfation is described by a pore size distribution model and long-residence-time sulfation by a particle expansion model. The pore size distribution model explains the effects of particle size, pore size distribution and partial pressure of SO{sub 2}, suggesting these three factors be the most important for CaO conversion. For particles larger than 1-2 {mu}m in furnace sorbent injection, pore diameters of 50-300 Aa are desirable. When large particles or long residence times are used, as in fluidized bed combustion, the particle expansion model shows the particle size and the sorbent type to be the main factors affecting the reaction. By using the selected limestone and additives the simultaneous SO{sub 2}/NO{sub x} removal was also measured. Several ammonium salts as well as urea were tested. Urea was found to give the highest NO{sub x} removal efficiency. To fully utilize the unreacted Ca-based sorbents, the spent sorbents from SO{sub 2} reduction processes were tested in a fixed-bed reactor to measure the capacity for HCl removal at 150-600 deg C. The results showed that all spent materials could react with HCl to some extent. After being calcined and slaked, they even showed the same reactivity as pure Ca(OH){sub 2}. A shrinking core model was derived for fixed-bed reactor. For the best sorbent tested, the multiple sorbent utilization reached about 80 %. 100 refs, 42 figs, 12 tabs

  7. Tolerance of bile duct to intraoperative irradiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.

    1982-01-01

    In order to determine the effects of intraoperative radiation therapy of the bile duct and surrounding tissues, seven adult dogs were subjected to laparotomy and intraoperative irradiation with 11 MeV electrons. Two animals were treated at each dose level of 2000, 3000, and 4500 rads. A single dog which received a laparotomy and sham irradiation served as a control. The irradiation field consisted of a 5 cm diameter circle encompassing the extrahepatic bile duct, portal vein, hepatic artery, and lateral duodenal wall. The animals were followed clinically for mor than 18 months after treatment, and autopsies were performed on dogs that died to assess radiation-induced complications or tissue damage. All dogs developed fibrosis and mural thickening of the common duct, which appeared by 6 weeks following irradiation and which was dose-related, being mild at low doses and more severe at high doses. Hepatic changes were seen as early as 6 weeks after irradiation, consisting of periportal inflammation and fibrosis. The hepatic changes appeared earliest at the highest doses. Frank biliary cirrhosis eventually developed at all dose levels. Duodenal fibrosis appeared in the irradiation portal, being most severe at the highest doses and in some animals resulting in duodenal obstruction. No changes were observed in irradiated portions of portal vein and hepatic artery at any dose level. It was concluded that intraoperative radiation therapy delivered to the region of the common duct leads to ductal fibrosis, partial biliary obstruction with secondary hepatic changes, and duodenal fibrosis if bowel wall is included in the field. Clinical use of intraoperative radiation therapy to the bile duct in humans may require routine use of biliary and duodenal bypass to prevent obstructive complications

  8. CT findings of thyroglossal duct cyst

    International Nuclear Information System (INIS)

    Kim, Dong Oh; Kim, Hong Soo; So, Hyun Soon; Nam, Mee Young; Choi, Jae Ho; Rhee, Hak Song

    1995-01-01

    The purpose of this study was to evaluate the CT findings of thyroglossal duct cysts. Sixteen patients with pathologically proved thyroglossal duct cysts were included in the study. CT scans were assessed retrospectively for shape, size, location, density of the central portions, septations, rim enhancement, changes in the adjacent fascial planes and investment within the strap muscles in the infrahyoid cysts. Thirteen cases of thyroglossal duct cysts were seen as round or oval cystic masses, two cases of them were seen as irregular-shaped lobulated cystic masses, and one case was seen as ovoid soft tissue mass. The cysts were from 1.4 to 5.7 cm in diameter (mean, 2.6 cm). The cyst was infrahyoid in 15 cases and suprahyoid in one case. The cyst was located in midline in eight cases, off midline in four cases, and both midline and off midline in four cases. The density of the central portions ranged from 15 to 82HU (mean, 32HU). Septations were noted in four cases. Rim enhancement was seen in 14 cases (93%), and heterogeneously enhancing soft tissue mass was seen in one case. In four cases, abnormal fascial planes were observed. All but one of the infrahyoid cysts (14/15) were embedded within the strap muscles, and one case of them was located anteriorly to strap muscles. CT permits one to make the diagnosis a thyroglossal duct cyst with a high degree of accuracy, as it can differentiate thyroglossal duct cysts from the other anterior neck masses by their typical location, characteristic morphology, and investment within the strap muscles

  9. Duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma.

    Science.gov (United States)

    Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin

    2013-04-21

    At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.

  10. Developing flow in S-shaped ducts. 2: Circular cross-section duct

    Science.gov (United States)

    Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.

    1984-01-01

    Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.

  11. Neutral beam injection optimization at TJ-II

    International Nuclear Information System (INIS)

    Fuentes, C.; Liniers, M.; Wolfers, G.; Alonso, J.; Marcon, G.; Carrasco, R.; Guasp, J.; Acedo, M.; Sanchez, E.; Medrano, M.; Garcia, A.; Doncel, J.; Alejaldre, C.; Tsai, C.C.; Barber, G.; Sparks, D.

    2005-01-01

    Neutral beam injection (NBI) heating has been used on the TJ-II stellarator for the first time. The beam has a port-through power between 200 and 400 kW and injection energy 28 kV. Beam transmission is limited by beam interception at the injection port and the first toroidal field coil, therefore, beam steering optimization is of critical importance. The beam interaction areas inside TJ-II vacuum chamber are surveyed by infrared thermography. Beam reionization can be a problem due to the presence of residual gas in the duct region. Halpha emission is used to monitor the reionization at the duct. A careful optimization of the injected gas has been carried out

  12. Long-term follow-up after choledochojejunostomy for bile duct stones with complex clearance of the bile duct

    NARCIS (Netherlands)

    Gouma, D. J.; Konsten, J.; Soeters, P. B.; Von Meyenfeldt, M.; Obertop, H.

    1989-01-01

    In this retrospective study, the long-term follow-up of patients undergoing choledochojejunostomy (Roux-en-Y) for bile duct stones with complex clearance of the bile duct is evaluated. Bile duct exploration and subsequent choledochojejunostomy (Roux-en-Y) was performed in 43 patients (median age 67

  13. Industrial Application of an Improved Multiple Injection and Multiple Staging Combustion Technology in a 600 MWe Supercritical Down-Fired Boiler.

    Science.gov (United States)

    Song, Minhang; Zeng, Lingyan; Chen, Zhichao; Li, Zhengqi; Zhu, Qunyi; Kuang, Min

    2016-02-02

    To solve the water wall overheating in lower furnace, and further reduce NOx emissions and carbon in fly ash, continuous improvement of the previously proposed multiple injection and multiple staging combustion (MIMSC) technology lies on three aspects: (1) along the furnace arch breadth, changing the previously centralized 12 burner groups into a more uniform pattern with 24 burners; (2) increasing the mass ratio of pulverized coal in fuel-rich flow to that in fuel-lean flow from 6:4 to 9:1; (3) reducing the arch-air momentum by 23% and increasing the tertiary-air momentum by 24%. Industrial-size measurements (i.e., adjusting overfire air (OFA) damper opening of 20-70%) uncovered that, compared with the prior MIMSC technology, the ignition distance of fuel-rich coal/air flow shortened by around 1 m. The gas temperature in the lower furnace was symmetric and higher, the flame kernel moved upward and therefore made the temperature in near-wall region of furnace hopper decrease by about 400 °C, the water wall overheating disappeared completely. Under the optimal OFA damper opening (i.e, 55%), NOx emissions and carbon in fly ash attained levels of 589 mg/m(3) at 6% O2 and 6.18%, respectively, achieving NOx and carbon in fly ash significant reduction by 33% and 37%, respectively.

  14. Acceptability of Global Positioning System technology to survey injecting drug users' movements and social interactions: a pilot study from San Francisco, USA.

    Science.gov (United States)

    Mirzazadeh, A; Grasso, M; Johnson, K; Briceno, A; Navadeh, S; McFarland, W; Page, K

    2014-01-01

    Despite potential applications for improving health services using GPS technology, little is known about ethical concerns, acceptability, and logistical barriers for their use, particularly among marginalized groups. We garnered the insights of people who inject drug (PWID) in San Francisco on these topics. PWID were enrolled through street-outreach (n=20) and an ongoing study (n=4) for 4 focus group discussions. Participants also completed a self-administered questionnaire on demographic characteristics and their numbers and types of interactions with other PWID. Median age was 30.5 years, majorities were male (83.3%) and white (68.2%). Most interacted with other PWID for eating meals and purchasing drugs over the last week; fewer reported interactions such as sexual contact, drug treatment, or work. Participants identified several concerns about carrying GPS devices, including what authorities might do with the data, that other PWID and dealers may suspect them as informants, and adherence to carrying and use. Most felt concerns were surmountable with detailed informed consent on the purpose of the study and practical ways to carry, charge, and hide devices. PWID felt data collection on their movements and social interactions with other PWID using GPS can be acceptable with addressing specific concerns. The technology is now in hand to greatly expand the ability to monitor health conditions with respect to the environment and improve the location of prevention, care, and treatment facilities to serve hard to reach, mobile, and hidden populations.

  15. Parotid Duct Repair with Intubation Tube: Technical Note

    Science.gov (United States)

    Öztürk, Muhammed Beşir; Barutca, Seda Asrufoğlu; Keskin, Elif Seda; Atik, Bekir

    2017-01-01

    The parotid duct can be damaged in traumatic injuries and surgical interventions. Early diagnosis and treatment of a duct injury is of great importance because complications such as sialocele and salivary gland fistula may develop if the duct is not surgically repaired. We think the cuff of an intubation tube is an ideal material in parotid duct repair, because of its technical characteristics, easiness of availability, and low-cost. In this paper, we described the use of the cuff cannula of an intubation tube for the diagnosis and treatment of parotid duct laceration, as a low-cost and easy to access material readily available in every operating room. PMID:28713751

  16. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  17. Radiologic imaging of bile duct changes by clonorchiasis

    International Nuclear Information System (INIS)

    Kim, Myung Joon; Yoo, Hyung Sik; Lee, Jong Tae; Jung, Soon Hee

    1988-01-01

    The changes of the bile ducts were reviewed retrospectively in 38 patients of clonorchiasis by ultrasonography and/or CT. Diagnosis was made in 13 patients by cholecystectomy and exploration of the common bile duct, another 2 patients by segmentectomy and wedge resection of the liver, and 23 patients by stool examination. 14 of 36 cases done ultrasonography showed the parallel channel sign, and small nodular echoes around the dilated bile ducts. And 3 cases showed the echoes of worm of clonorchis sinensis in the common bile duct. 22 of 36 cases showed the parallel channel signs only. All cases (11) done CT showed diffuse dilatation of the peripheral bile ducts. 5 of 11 cases showed ring or tubular contrast enhancement around the dilated bile ducts. In 2 cases of liver resection, the bile ducts showed adenomatous hyperplasia and severe periductal fibrosis. Proliferation of blood vessels and infiltration of inflammatory cells were also seen. So we consider that the increased echoes of the bile duct wall, small nodular echoes around the bile ducts were attributed to the bile duct dilatation, severe adenomatous hyperplasia and periductal fibrosis. The ring or tubular contrast enhancement of the dilated bile ducts seems to be caused by the marked periductal inflammation resulting in capillary proliferation and the periductal fibrosis.

  18. Radiologic imaging of bile duct changes by clonorchiasis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Joon; Yoo, Hyung Sik; Lee, Jong Tae; Jung, Soon Hee [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-10-15

    The changes of the bile ducts were reviewed retrospectively in 38 patients of clonorchiasis by ultrasonography and/or CT. Diagnosis was made in 13 patients by cholecystectomy and exploration of the common bile duct, another 2 patients by segmentectomy and wedge resection of the liver, and 23 patients by stool examination. 14 of 36 cases done ultrasonography showed the parallel channel sign, and small nodular echoes around the dilated bile ducts. And 3 cases showed the echoes of worm of clonorchis sinensis in the common bile duct. 22 of 36 cases showed the parallel channel signs only. All cases (11) done CT showed diffuse dilatation of the peripheral bile ducts. 5 of 11 cases showed ring or tubular contrast enhancement around the dilated bile ducts. In 2 cases of liver resection, the bile ducts showed adenomatous hyperplasia and severe periductal fibrosis. Proliferation of blood vessels and infiltration of inflammatory cells were also seen. So we consider that the increased echoes of the bile duct wall, small nodular echoes around the bile ducts were attributed to the bile duct dilatation, severe adenomatous hyperplasia and periductal fibrosis. The ring or tubular contrast enhancement of the dilated bile ducts seems to be caused by the marked periductal inflammation resulting in capillary proliferation and the periductal fibrosis.

  19. IMPACT OF FORMULA-TECHNOLOGICAL FACTORS ON CONCRETE STRENGTH INDICATORS FOR INJECTING WITH TWO-STAGE EXPANSION

    Directory of Open Access Journals (Sweden)

    Tatjana N. Zhilnikova

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the study is to clarify the dependence of the cement stone strength on additional porosity that is formed owing both to the cement stone’s development of free deformations and the expansion of the hardening concrete in the second stage as caused by the action of the expanding additive. Method The study is based on the introduction of a sulphoaluminate-type expanding additive in the composition of a binder based on alumina cement, natural gypsum stone and nitrilotrimethylphosphonic acid. Results It is shown that an important role is played in the technology of expanding concrete not only by the degree of expansion of the cement stone, but also by its strength, both during the development of deformations and following stabilisation. Among factors influencing the kinetics of hardening are not only recipe-related (composition and dosage of the additive, mineralogical composition of Portland cement clinker, composition of the concrete, presence of chemical additives, but also technological (fineness of cement grinding, hardening temperature, etc. that makes the management of the processes of structure formation quite complex. The dependence of the strength of cement stone on the additional porosity formed due to the growth of the cement stone own free deformations and expansion of the hardening concrete in the second stage due to the action of the expanding additive is revealed; dependence of the influence of kinetics of the structure formation regulator - nitrilotrimethylphosphonic acid - on the consistency of the development of the intrinsic free expansion deformations and the formation of the strength of the cement stone in the second stage; the dependence of the strength of the cement stone on the additional porosity formed due to gas evolution and expansion of the mixture in the first stage due to the action of the gas-forming additive; the influence of the constraint of expansion on the formation of the

  20. A Case of Adenomyomatous Hyperplasia of the Extrahepatic Bile Duct

    Directory of Open Access Journals (Sweden)

    Masakatsu Numata

    2011-08-01

    Full Text Available Adenomyomatous hyperplasia is rarely found in the extrahepatic bile duct. A 54-year-old man was referred to our center with a diagnosis of extrahepatic bile duct stenosis which had been detected by endoscopic retrograde choloangiopancreatography. Abdominal computed tomography revealed thickening of the wall of the middle extrahepatic bile duct, however no malignant cells were detected by cytology. Since bile duct carcinoma could not be ruled out, we performed resection of the extrahepatic duct accompanied by lymph node dissection. Histopathologically, the lesion was diagnosed as adenomyomatous hyperplasia of the extrahepatic bile duct. Present and previously reported cases showed the difficulty of making a diagnosis of adenomyomatous hyperplasia of the extrahepatic bile duct preoperatively or intraoperatively. Therefore, when adenomyomatous hyperplasia is suspected, a radical surgical procedure according to malignant disease may be necessary for definitive diagnosis.

  1. Dispersion properties of ducted whistlers, generated by lightning discharge

    Directory of Open Access Journals (Sweden)

    D. L. Pasmanik

    2005-06-01

    Full Text Available Whistler-mode wave propagation in magnetospheric ducts of enhanced cold plasma density is studied. The case of the arbitrary ratio of the duct radius to the whistler wavelength is considered, where the ray-tracing method is not applicable. The set of duct eigenmodes and their spatial structure are analysed and dependencies of eigenmode propagation properties on the duct characteristics are studied. Special attention is paid to the analysis of the group delay time of one-hop propagation of the whistler wave packet along the duct. We found that, in contrast to the case of a wide duct, the group delay time in a rather narrow duct decreases as the eigenmode number increases. The results obtained are suggested for an explanation of some types of multi-component whistler signals.

  2. Spectral measurements of gamma radiation streaming through ducts

    International Nuclear Information System (INIS)

    Meenakshisundaram, P.K.; Bhatnagar, V.M.; Raghunath, V.M.; Gopinath, D.V.

    1979-01-01

    The paper presents the spectral measurements of gamma radiation streaming through multi-legged rectangular concrete ducts for cesium-137 and cobald-60 sources. Effect of lead lining the inner surface of the duct on the streaming radiation spectrum and optimization of liner thickness for minimum streaming radiation dose have been studied. For three-legged ducts, a comparative analysis of lead lining the entire duct as against lining any one or both the corners of the duct is reported. It is seen that lead lining any one of the corners would reduce the streaming radiation dose by a factor of 5 to 12. Lining both the corners which is nearly as effective as lining the entire duct reduces the dose by a factor of 16 to 60 depending on the soruce energy and duct dimensions. (orig.)

  3. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  4. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  5. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  6. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  7. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  8. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  9. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  10. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  11. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  12. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  13. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  14. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  15. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  16. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  17. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  18. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  19. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  20. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  1. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  2. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  3. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  4. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  5. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  6. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  7. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  8. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  9. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  10. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  11. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  12. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  13. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  14. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  15. SNM holdup assessment of Los Alamos exhaust ducts

    International Nuclear Information System (INIS)

    Marshall, R.S.

    1994-02-01

    Fissile material holdup in glovebox and fume hood exhaust ducting has been quantified for all Los Alamos duct systems. Gamma-based, nondestructive measurements were used to quantify holdup. The measurements were performed during three measurement campaigns. The first campaign, Phase I, provided foot-by-foot, semiquantitative measurement data on all ducting. These data were used to identify ducting that required more accurate (quantitative) measurement. Of the 280 duct systems receiving Phase I measurements, 262 indicated less than 50 g of fissile holdup and 19 indicated fissile holdup of 50 or more grams. Seven duct systems were measured in a second campaign, called Series 1, Phase II. Holdup estimates on these ducts ranged from 421 g of 235 U in a duct servicing a shut-down uranium-machining facility to 39 g of 239 Pu in a duct servicing an active plutonium-processing facility. Measurements performed in the second campaign proved excessively laborious, so a third campaign was initiated that used more efficient instrumentation at some sacrifice in measurement quality. Holdup estimates for the 12 duct systems measured during this third campaign ranged from 70 g of 235 U in a duct servicing analytical laboratories to 1 g of 235 U and 1 g of 239 Pu in a duct carrying exhaust air to a remote filter building. These quantitative holdup estimates support the conclusion made at the completion of the Phase I measurements that only ducts servicing shut-down uranium operations contain about 400 g of fissile holdup. No ventilation ducts at Los Alamos contain sufficient fissile material holdup to present a criticality safety concern

  16. Tracer gas dispersion in ducts-study of a new compact device using arrays of sonic micro jets

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A.R. [Instituto Nacional de Engenharia e Tecnologia Industrial (INETI), Lisboa (Portugal); Afonso, C.F. [Faculdade de Engenharia, Universidade do Porto Departmento de Mecanica e Gestao Industrial, Porto (Portugal)

    2004-07-01

    One of the most feasible ways to measure duct airflows is by tracer gas techniques, especially for complex situations when the duct lengths are short as well as their access, which makes extremely difficult or impossible other methods to be implemented. One problem associated with the implementation of tracer gas technique when the ducts lengths are short is due to the impossibility of achieving complete mixing of the tracer with airflow and its sampling. In this work, the development of a new device for the injection of tracer gas in ducts is discussed as well as a new tracer-sampling device. The developed injection device has a compact tubular shape, with magnetic fixation to be easy to apply in duct walls. An array of sonic micro jets in counter current direction, with the possibility of angular movement according to its main axle ensures a complete mixing of the tracer in very short distances. The tracer-sampling device, with a very effective integration function, feeds the sampling system for analysis. Both devices were tested in a wind tunnel of approximately 21 m total length. The tests distances between injection and integration device considered were: X/Dh = 22; X/Dh = 4; X/Dh 2; and X/Dh = 1. For very short distances of X/Dh = 2 and X/Dh = 1, semi-empirical expressions were needed. A good reproducibility of airflow rate values was obtained. These preliminary tests showed that the practical implementation of tracer gas techniques in HVAC systems for measuring airflow rates with a very short mixing distance is possible with the devices developed. (author)

  17. Acoustic Power Transmission Through a Ducted Fan

    Science.gov (United States)

    Envia, Ed

    2016-01-01

    For high-speed ducted fans, when the rotor flowfield is shock-free, the main contribution to the inlet radiated acoustic power comes from the portion of the rotor stator interaction sound field that is transmitted upstream through the rotor. As such, inclusion of the acoustic transmission is an essential ingredient in the prediction of the fan inlet noise when the fan tip relative speed is subsonic. This paper describes a linearized Euler based approach to computing the acoustic transmission of fan tones through the rotor. The approach is embodied in a code called LINFLUX was applied to a candidate subsonic fan called the Advanced Ducted Propulsor (ADP). The results from this study suggest that it is possible to make such prediction with sufficient fidelity to provide an indication of the acoustic transmission trends with the fan tip speed.

  18. Impact fracture behavior of HT9 duct

    International Nuclear Information System (INIS)

    Huang, F.H.; Gelles, D.S.

    1994-07-01

    Ferritic alloys are known to undergo a ductile-brittle transition as the test temperature is decreased. This inherent problem has limited their applications to reactor component materials subjected to low neutron exposures. However, the excellent resistance to void swelling exhibited by these alloys has led to choosing the materials as candidate materials for fast and fusion reactor applications. Despite the ductile-brittle transition problem, results show that the materials exhibit superior resistance to fracture under very high neutron fluences at irradiation temperatures above 380 degrees C. Impact testing on FFTF duct sections of HT9 indicates that HT9 ducts have adequate fracture toughness at much higher temperatures for handling operations at room temperature and refueling operations

  19. Mullerian Ducts Anomalies: A Simple View

    International Nuclear Information System (INIS)

    Diaz Diaz, Nelson Enrique; Riano Montanez, Yeyson Fabian; Baron Criollo, Jose alexander

    2008-01-01

    Mullerian ducts anomalies are a major cause of infertility in women of reproductive age. They have multifactorial etiology. The following article reviews the classification of the American Fertility Society, the most widely accepted at present to describe this set of pathologies. Also a schematic review of the embryology is done and are shown cases of MRI, modality of choice by image to characterize the findings in the majority of presentation forms of these entities

  20. T-method duct design. Part 3

    International Nuclear Information System (INIS)

    Tsal, R.J.; Behls, H.F.; Mangel, R.

    1990-01-01

    This paper introduces a new method for simulating HVAC duct systems, called T-method. The desirability of simulation appears in many HVAC problems, such as determining system operating efficiency, system retrofitting, nuclear plant normal/emergency conditions, fire/smoke control systems, fans operating in parallel, pressure balancing after system modification, and noise generated by dampers. T-method is capable of simulating these problems. This paper includes problem definition, a theoretical approach, calculation procedures, and many examples

  1. Pressure drop in T's in concentric ducts

    International Nuclear Information System (INIS)

    Shock, R.A.W.

    1983-02-01

    A set of experiments has been carried out to measure the pressure drop characteristics of single-phase flow in dividing and joining right-angled T's in a concentric ducting system. These have been compared with measured pressure drops in a simple round tube system. In most tests with the concentric system the number of velocity heads lost is either similar to, or more than, the value for the round tubes. (author)

  2. Specific aspects of turbulent flow in rectangular ducts

    Directory of Open Access Journals (Sweden)

    Stanković Branislav D.

    2017-01-01

    Full Text Available The essential ideas of investigations of turbulent flow in a straight rectangular duct are chronologically presented. Fundamentally significant experimental and theoretical studies for mathematical modeling and numerical computations of this flow configuration are analyzed. An important physical aspect of this type of flow is presence of secondary motion in the plane perpendicular to the streamwise direction, which is of interest from both the engineering and the scientific viewpoints. The key facts for a task of turbulence modeling and optimal choice of the turbulence model are obtained through careful examination of physical mechanisms that generate secondary flows. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no.TR-33018: Increase in Energy and Ecology Efficiency of Processes in Pulverized Coal-Fired Furnace and Optimization of Utility Steam Boiler Air Pre-heater by Using In-House Developed Software Tools

  3. Hinkley Point A gas duct repairs

    International Nuclear Information System (INIS)

    Curtis, R.F.

    1996-01-01

    In 1990, routine visual inspection of the Hinckley Point A Reactor 1 pressure vessel gas outlet ducts showed failures in the welded stud bolts retaining the insulation edging strips. Since the ducts are accessible only from within the pressure vessel, a remote repair technique that could be deployed via the vessel stand pipe had to be found. A drawn arc stud welding and work package formerly used at the Oldbury Power Station was modified for the purpose. The only manipulators with sufficient reach and adequate carrying capacity to deploy the package were the Sizewell SNAKES manipulators. One of these was modified to fit the Hinckley reactor and repairs have been successfully carried out. Similar studs on the gas ducts in Reactor 2, are shielded from visual inspection by a Z-clip feature. A technique using pulsed thermography was developed. The studs were heated for a short time at their exposed ends using a prefocused lamp and the heat decay patterns monitored by an infrared camera enabling attached and detached studs to be distinguished. The inspection package was deployed using the SNAKES manipulator again. In both operations, I-Grip computer modelling was used in the design of the package envelope and the deployment routes. (UK)

  4. Dynamic response of cracked hexagonal subassembly ducts

    International Nuclear Information System (INIS)

    Glazik, J.L.; Petroski, H.J.

    1979-01-01

    The hexagonal subassembly ducts (hexcans) of current Liquid Metal Fast Breeder Reactor (LMFBR) designs are typically made of 20% coldworked Type 316 stainless steel. Prolonged exposure of this initially tough and ductile material to a fast neutron flux at high temperatures can result in severe embrittlement. Under these conditions, the unstable crack propagation of flaws, which may have been introduced during fabrication or transportation of the hexcans, is a problem of interest in LMFBR safety analysis. The abnormal overpressurization resulting from certain interactions within a subassembly, or the rupture of one or more fuel pins, may be sufficient to overload an otherwise subcritical crack in an embrittled hexcan. This paper examines the dynamic elastic response of flawed and unflawed fast reactor subassembly ducts. A plane-strain finite element analysis was performed for ducts containing internal corner cracks, as well as external midflat cracks. Two worst case loading situations were considered: rapid uniform internal pressurization and suddenly applied point loads at opposite midflats. The finite-element code CHILES, which can accomodate the stress singularities that occur at crack tips, was given dynamic capabilities through the inclusion of a consistent mass matrix and step-by-step time integration scheme. The SAP IV code was also employed for eigenvalue analysis and modal response. Although this code does not contain singular elements in its element library, dynamic stress intensity factors were calculated by a technique requiring only ordinary isoparametric quadrilaterals

  5. Applied Technologies and Prospects of Conformance Control Treatments in China Technologies et perspectives pour l’amélioration du profil de balayage dans les champs pétroliers matures produits par injection d’eau en Chine

    Directory of Open Access Journals (Sweden)

    Liu Yuzhang

    2010-02-01

    Full Text Available China is the largest user of chemical-based conformance control treatments and a series of technologies have been successfully developed and deployed in recent years. This paper first shows the milestones of development and application of conformance control technologies in China. Then integrated conformance control technologies are reviewed followed by the lessons we have learned, and then a few major specific conformance control technologies are addressed, including tracer injection and channels explanation, potentiometric testing to identify areal sweep efficiency, Pressure Index (PI decisionmaking technology to select well candidate, complementary decision-making technology to select well candidate and design application parameters, and major chemicals for in-depth fluid diversion technologies. In addition, this paper also describes the principles and applications of some promising technologies of combined chemical-based conformance treatment with other EOR/IOR process, including the combination technology of surfactant and water shutoff, profile control and mini-scale surfactant flooding, acid treatment and profile control treatment. Finally, this paper summarizes the problems and challenges faced by mature water flooded oilfields in China. Based on recent well tests, tracer testing and interpretation, and previous water control treatment experience, it appears that channels or high permeability streaks are common in mature water flooded oilfields. Some research directions and promising technologies are suggested. La Chine est le plus grand utilisateur de méthodes chimiques pour l’amélioration du profil de balayage de l’eau pour l’exploitation des champs pétroliers matures. Toute une série de technologies y ont d’ailleurs été créées et déployées avec succès ces dernières années. Cet article commence par présenter les étapes du développement et de la mise en place de ces technologies de contrôle de profil en Chine

  6. Effect of duct geometry on Wells turbine performance

    International Nuclear Information System (INIS)

    Shaaban, S.; Abdel Hafiz, A.

    2012-01-01

    Highlights: ► A Wells turbine duct design in the form of venturi duct is proposed and investigated. ► Optimum duct geometry is identified. ► Up to 14% increase of the turbine power can be achieved using the optimized duct geometry. ► Up to 9% improve of the turbine efficiency is attained by optimizing the turbine duct geometry. ► The optimized duct geometry results in tangible delay of the turbine stalling point. - Abstract: Wells turbines can represent important source of renewable energy for many countries. An essential disadvantage of Wells turbines is their low aerodynamic efficiency and consequently low power produced. In order to enhance the Wells turbine performance, the present research work proposes the use of a symmetrical duct in the form of a venturi tube with turbine rotor located at throat. The effects of duct area ratio and duct angle are investigated in order to optimize Wells turbine performance. The turbine performance is numerically investigated by solving the steady 3D incompressible Reynolds Averaged Navier–Stocks equation (RANS). A substantial improve of the turbine performance is achieved by optimizing the duct geometry. Increasing both the duct area ratio and duct angle increase the acceleration and deceleration upstream and downstream the rotor respectively. The accelerating flow with thinner boundary layer thickness upstream the rotor reduces the flow separation on the rotor suction side. The downstream diffuser reduces the interaction between tip leakage flow and blade suction side. Up to 14% increase in turbine power and 9% increase in turbine efficiency are achieved by optimizing the duct geometry. On other hand, a tangible delay of the turbine stall point is also detected.

  7. Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-07

    "9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

  8. Imaging manifestation of hepatocellular carcinoma with bile duct tumor thrombi

    International Nuclear Information System (INIS)

    Liu Qingyu; Chen Jianyu; Liang Biling; Hu Tao

    2008-01-01

    Objective: To analyze the imaging features of hepatocellular carcinoma(HCC) with bile duct tumor thrombi. Methods: Thirteen patients with bile duct tumor thrombi proved pathologically underwent imaging examination. MR and CT were performed in 3 cases, and 2 cases had CT only and 8 cases had MRI only. Ultrasonography(US) was performed in all 13 patients. The accuracy of bile duct tumor thrombi detection was compared between US, CT and MRI with Fisher test. Results: Liver tumors and bile duct tumor thrombi were demonstrated in all patients on CT or MRI. Presence of intraluminal soft tissue mass was found in four of five cases on CT, and mild enhancement of the intraluminal mass in the arterial phase was noted, dilated bile duct distal to tumor thrombi was detected in all five patients. Eleven Tumor thrombi showed slight low signal intensity on T 1 WI, slight high signal intensity on T 2 WI, and mild to moderate contrast enhancement on the contrast-enhanced MR images. The MRCP findings of tumor thrombi were as follows: interruption, stricture of the bile ducts or irregular filling defect in the bile ducts with dilated intrahepatic ducts, bile duet was abruptly interrupted or showed a 'rat-tail' stricture (n=5); the common bile duct was filled with tumor thrombi, intrahepatic bile duct dilatation and missing common bile duct was noted on MRCP (n=2). Bile duct tumor thrombi were correctly diagnosed in 7 cases on US, and 12 cases on CT or MRI. Six cases were misdiagnosed or miss-diagnosed on US, and 4 cases were misdiagnosed on CT or MRI. There was no significant difference between US and CT/MRI in diagnosis of bile duct tumor thrombi (P=0.270). Conclusion: CT or MR imaging is useful for the diagnosis of HCC with biliary tumor thrombi and for evaluating the extension of thrombi. (authors)

  9. Unilateral Duplication Of Parotid Duct. A Rare Anatomical Variation

    Directory of Open Access Journals (Sweden)

    Humberto Ferreira Arquez

    2017-11-01

    Full Text Available Background: The paired parotid glands are the largest of the major salivary glands and produces mainly serous secretions. The secretion of this gland reaches the oral cavity through single parotid duct (Stensen’s duct. The parotid duct begins at the anterior border of the gland, crosses the masseter muscle, and then pierces the buccinator muscle to reach the mucosa lining the mouth at the level of the cheek. The purpose of this study is determine the morphologic features of the parotid duct and describe an anatomical variation until now unreported. Methods and Findings: A total of 17 cadavers were used for this study in the Morphology Laboratory at the University of Pamplona. In a cadaver were findings: The main parotid duct originated two conducts: Left superior parotid duct and Left inferior parotid duct, is observed the criss-cross of the ducts, and then perforated the buccinator muscle and entered the oral cavity at a double parotid papilla containing a double opening, separated from each other in 0,98 mm. In the remaining  33 parotid regions (97.06% the parotid duct is conformed to the classical descriptions given in anatomical textbooks. Conclusions: The parotid duct anatomy is important for duct endoscopy, lithotripsy, sialography and trans-ductal facial nerve stimulation in the early stage of facial palsy in some cases. The anatomical variations also has clinical importance for parotid gland surgery and facial cosmetic surgery. To keep in mind the parotid duct variation will reduce iatrogenic injury risks and improve diagnosis of parotid duct injury.

  10. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, Malachi; Ayyagari, Raj R. [Yale School of Medicine, Yale New Haven Hospital, New Haven, CT (United States); Division of Interventional Radiology, Department of Radiology, 789 Howard Avenue, P.O. Box 208042, New Haven, CT (United States)

    2015-06-15

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  11. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    International Nuclear Information System (INIS)

    Courtney, Malachi; Ayyagari, Raj R.

    2015-01-01

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  12. Eversion Bile Duct Anastomosis: A Safe Alternative for Bile Duct Size Discrepancy in Deceased Donor Liver Transplantation.

    Science.gov (United States)

    Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw

    2018-04-10

    Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.

  13. Pressure analysis in ventilation ducts at bituminization facility

    International Nuclear Information System (INIS)

    Kikuchi, Naoki; Iimura, Masato; Takahashi, Yuki; Omori, Eiichi; Yamanouchi, Takamichi

    1997-09-01

    Pressure analysis in cell ventilation ducts at bituminization facility where the fire and explosion accident occured was carried out. This report also describes the results of bench mark calculations for computer code EVENT84 which was used for the accident analysis. The bench mark calculations were performed by comparing the analytical results by EVENT84 code with the experimental data of safety demonstration tests of ventilation system which were carried out by JAERI. We confirmed the applicability of EVENT84 code with the conservative results. The pressure analysis in cell ventilation ducts at bituminization facility were performed by comparing the analytical results of duct pressure by EVENT84 code with the yield stress of destroyed ducts by explosion, in order to estimate the scale of explosion. As a result, we could not explain the damage of ducts quantitatively, but we found the local pressure peaks analytically in downstream ducts where the serious damages were observed. (author)

  14. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  15. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  16. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  17. Active noise control in a duct to cancel broadband noise

    Science.gov (United States)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.

  18. Hepatocellular carcinoma with bile duct involvement : computed Tomographic (CT) findings

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Han, Joon Koo; Kim, Tae Kyoung; And others

    2000-01-01

    To describe the radiologic features of computed tomography (CT) in hepatocellular carcinoma (HCC) with bile duct involvement. We retrospectively analyzed the two phase spiral CT findings of 31 patients in whom HCC with bile duct invasion (n=3D28) or compression (n=3D3), was diagnosed. Eight of these underwent follow up CT after transarterial chemoembolization. We analyzed the size, type, location, enhancement pattern, and lipiodol retention of parenchymal and intraductal masses, as well as their lymphadenopathy. In all patients with bile duct invasion, single or multiple masses were demonstrated in the bile ducts. Intraductal masses showed the same enhancement characteristics as the parenchymal mass (kappa 0.550, p less than 0.001), and were contiguous to this mass. In 14 of 28 patients, intraductal masses filled the peripheral intrahepatic bile ducts and extended to the common bile ducts. In the other 14, the parenchymal mass extended to the area of the porta hepatis and then directly invaded the large ducts. In nine of the 28 patients, there was a hypoattenuated cleft between the intraductal mass and ductal wall. In six, a parenchymal mass was not apparent (n=3D2), or was smaller than 2cm (n=3D4). In five of eight patients (62.5%), follow-up CT after transarterial chemoembolization showed compact or partial lipiodol retention within the intraductal mass. In patients with bile duct compression, perihilar lymph nodes were noted along with the dilated intrahepatic duct but no intra ductal mass was demonstrated in the duct. Hepatocellular carcinomas cause bile duct dilatation either by direct invasion or by extrinsic compression of the bile duct with surrounding enlarged nodes. For the diagnosis of this condition, CT is helpful. (author)

  19. Risk factors for central bile duct injury complicating partial liver resection

    NARCIS (Netherlands)

    Boonstra, E. A.; de Boer, M. T.; Sieders, E.; Peeters, P. M. J. G.; de Jong, K. P.; Slooff, M. J. H.; Porte, R. J.

    Background: Bile duct injury is a serious complication following liver resection. Few studies have differentiated between leakage from small peripheral bile ducts and central bile duct injury (CBDI), defined as an injury leading to leakage or stenosis of the common bile duct, common hepatic duct,

  20. Winglet and long duct nacelle aerodynamic development for DC-10 derivatives

    Science.gov (United States)

    Taylor, A. B.

    1978-01-01

    Advanced technology for application to the Douglas DC-10 transport is discussed. Results of wind tunnel tests indicate that the winglet offers substantial cruise drag reduction with less wing root bending moment penalty than a wing-tip extension of the same effectiveness and that the long duct nacelle offers substantial drag reduction potential as a result of aerodynamic and propulsion improvements. The aerodynamic design and test of the nacelle and pylon installation are described.

  1. Computed tomography of hepatocellular carcinoma. Dilatation of intrahepatic bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soomi; Nakamura, Hitonobu; Tanaka, Ken; Hori, Shinichi; Tokunaga, Kou [Osaka Univ. (Japan). Faculty of Medicine

    1983-10-01

    Based on a series of CT of the liver in 125 patients with hepatoma and 45 patients with metastatic hepatic tumors, the mode of dilatation of the intrahepatic bile duct was examined. In patients with hepatoma, partia dilatations of intrahepatic bile duct were more commonly seen than general dilatations. On the other hand, there was no case of partial dilatation of the intrahepatic bile duct in patients with metastatic hepatic tumors. It could be concluded that partial dilatation of the intrahepatic bile duct is an useful CT finding to make a diagnosis of hepatoma, particularly to differentiate hepatoma from metastatic hepatic tumor.

  2. ATP release, generation and hydrolysis in exocrine pancreatic duct cells

    DEFF Research Database (Denmark)

    Kowal, Justyna Magdalena; Yegutkin, G.G.; Novak, Ivana

    2015-01-01

    Extracellular adenosine triphosphate (ATP) regulates pancreatic duct function via P2Y and P2X receptors. It is well known that ATP is released from upstream pancreatic acinar cells. The ATP homeostasis in pancreatic ducts, which secrete bicarbonate-rich fluid, has not yet been examined. First, ou...... may be important in pancreas physiology and potentially in pancreas pathophysiology....... aim was to reveal whether pancreatic duct cells release ATP locally and whether they enzymatically modify extracellular nucleotides/sides. Second, we wished to explore which physiological and pathophysiological factors may be important in these processes. Using a human pancreatic duct cell line, Capan...

  3. Duct Remediation Program: Engineered access research and construction

    International Nuclear Information System (INIS)

    Beckman, T.D.; Davis, M.M.; Karas, T.M.

    1992-01-01

    The Rocky Flats Plant, Duct Remediation mission concentrated on removing Plutonium Oxide from the process ductwork in the primary Plutonium processing facility. When possible, remediation took place from existing process gloveboxes. Fifteen locations were identified, however, that required accessing duct runs where no process gloveboxes existed. The building's second floor utility areas had many locations where long, inaccessible duct runs were prevalent. Consequently, an extensive program for design, procurement and construction was initiated to contain and isolate ducts for penetration when existing glovebox sites were not present

  4. Occlusion of the cystic duct by electrocoagulation: A radiologic technique

    International Nuclear Information System (INIS)

    Becker, C.D.; Quenville, W.F.; Burhenne, H.J.

    1987-01-01

    Chemical dissolution and extracorporeal shock wave lithotripsy are promising new methods for the treatment of cholelithiasis without cholecystectomy. Nonsurgical defunctionalization of the gallbladder is now required to prevent recurrent stone formation. The authors consider cystic duct occlusion to be the first step. Ten domestic pigs underwent transcatheter electrocoagulation of the cystic duct via a cholecystostomy under fluoroscopic control. Stricture formation was followed by complete cystic duct occlusion in all ten cases. After a follow-up period ranging from 2 to 17 weeks (mean, 13 weeks), the animals were killed. Histologic studies demonstrated that complete obliteration of the cystic duct lumen was due to fibrous scar formation

  5. Effectiveness of duct sealing and duct insulation in multi-family buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Karins, N.H.; Tuluca, A.; Modera, M.

    1997-07-01

    This research investigated the cost-effectiveness of sealing and insulating the accessible portions of duct systems exposed to unconditioned areas in multifamily housing. Airflow and temperature measurements were performed in 25 apartments served by 10 systems a 9 multi-family properties. The measurements were performed before and after each retrofit, and included apartment airflow (supply and return), duct system temperatures, system fan flow and duct leakage area. The costs for each retrofit were recorded. The data were analyzed and used to develop a prototypical multifamily house. This prototype was used in energy simulations (DOE-2.1E) and air infiltration simulations (COMIS 2.1). The simulations were performed for two climates: New York City and Albany. In each climate, one simulation was performed assuming the basement was tight, and another assuming the basement was leaky. Simulation results and average retrofit costs were used to calculate cost-effectiveness. The results of the analysis indicate that sealing leaks of the accessible ductwork is cost-effective under all conditions simulated (simple payback was between 3 and 4 years). Insulating the accessible ductwork, however, is only cost-effective for buildings with leaky basement, in both climates (simple paybacks were less than 5 years). The simple payback period for insulating the ducts in buildings with tight basements was greater than 10 years, the threshold of cost-effectiveness for this research. 13 refs., 5 figs., 27 tabs.

  6. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  7. Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

    Science.gov (United States)

    Eichenberg, Dennis J.; Emerson, Dawn C.; Gallo, Christopher A.; Thompson, William K.

    2011-01-01

    This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

  8. Physics basis and mechanical design of the actively cooled duct scraper protection for the JET neutral beam enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D.J. [UKAEA Fusion/Euratom Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)], E-mail: dwilson@jet.uk; Ciric, D.; Cox, S.J.; Jones, T.T.C.; Kovari, M. [UKAEA Fusion/Euratom Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Li Puma, A. [Association EURATOM-CEA, CEA-Cadarache, 13108 St. Paul-Lez-Durance (France); Martin, D.; Milnes, J.; Shannon, M.; Surrey, E. [UKAEA Fusion/Euratom Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2007-10-15

    The objectives of the JET neutral beam enhancement (NBE) include raising the delivered power from the present 25 MW to more than 34 MW and increasing the pulse length from 10 to 20 s. The additional power will be obtained partly by increasing the fractional energy components of the beam, resulting from acceleration of molecular ions, hence increasing the total particle flux. These changes place extreme demands on the design of the upgraded protection to the torus entry duct. The present inertial duct protection already reaches its thermomechanical limit in 10 s pulses, and active cooling of the upgraded duct protection is therefore essential. Extensive analysis of the pressure and temperature evolution in the present un-cooled duct established the relationship between gas re-emission and surface temperature for copper in this operating environment. This information was used in an integrated physics and engineering approach to the design of the actively cooled duct protection, taking into account the power loads from direct beam interception and re-ionisation. Surface temperature determines power density through the gas re-emission and consequential beam re-ionisation. These considerations define the normal operating point for the chosen enhanced hypervapotron element technology. This approach demonstrated that supplementary in situ duct cryopumping would not be needed, provided that the required heat-transfer performance could be met without any encroachment of the elements beyond the space envelope of the existing inertial duct protection plates. This requirement posed severe constraints on the mechanical design of the hypervapotron element array and its manifolding; the adopted engineering design solutions are presented.

  9. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    Science.gov (United States)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  10. Common bile duct cancer with massive necrosis mimicking choledochal dilatation on CT

    International Nuclear Information System (INIS)

    Miyake, H.; Matsumoto, S.; Ueda, S.; Maeda, T.; Aikawa, H.; Mori, H.

    1991-01-01

    Carcinomas of the common bile duct are usually seen as dilatation of the bile duct proximal to a solid mass on CT. In the case reported here, the common bile duct cancer itself mimicked dilated common bile duct on CT because of massive necrosis. In a case of simulating dilated common bile duct on CT, and discrepancy between CT and ultrasonography or endoscopic retrograde cholangiopancreatography, a common bile duct cancer with massive necrosis should be included in the differential diagnosis. (orig.)

  11. Morphological study of pancreatic duct in red jungle fowl | Kadhim ...

    African Journals Online (AJOL)

    Neither goblet cells nor ductal glands were found in the pancreatic ducts. Secretion of both neutral and sulfated materials by the epithelial lining the pancreatic ducts, suggesting that they are acting not only to facilitate the transport of the pancreatic juice, but also as a protective barrier to protect the gland from autodigestion.

  12. Ursodeoxycholic acid treatment of vanishing bile duct syndromes

    NARCIS (Netherlands)

    Pusl, Thomas; Beuers, Ulrich

    2006-01-01

    Vanishing bile duct syndromes (VBDS) are characterized by progressive loss of small intrahepatic ducts caused by a variety of different diseases leading to chronic cholestasis, cirrhosis, and premature death from liver failure. The majority of adult patients with VBDS suffer from primary biliary

  13. Bile duct anastomotic stricture after pediatric living donor liver transplantation.

    Science.gov (United States)

    Chok, Kenneth S H; Chan, See Ching; Chan, Kwong Leung; Sharr, William W; Tam, Paul K H; Fan, Sheung Tat; Lo, Chung Mau

    2012-07-01

    Hepaticojejunostomy is a well-accepted method, whereas duct-to-duct anastomosis is gaining popularity for bile duct reconstruction in pediatric living donor liver transplantation (LDLT). Biliary complications, especially biliary anastomotic stricture (BAS), are not clearly defined. The aim of the present study is to determine the rate of BAS and its associated risk factors. The study included 78 pediatric patients (duct-to-duct anastomosis during LDLT. The median follow-up period for the BAS group and the non-BAS group was 57.8 and 79.5 months, respectively (P = .683). Ten of the patients with BAS required percutaneous transhepatic biliary drainage with or without dilatation for treating the stricture. Multivariable analysis showed that hepatic artery thrombosis and duct-to-duct anastomosis were 2 risk factors associated with BAS. In pediatric LDLT, hepaticojejunostomy is the preferred method for bile duct reconstruction, but more large-scale research needs to be done to reconfirm this result. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Liver and Bile Duct Cancer—Patient Version

    Science.gov (United States)

    Liver cancer includes hepatocellular carcinoma and bile duct cancer (cholangiocarcinoma). Risk factors for HCC include chronic infection with hepatitis B or C and cirrhosis of the liver. Start here to find information on liver and bile duct cancer treatment, causes and prevention, screening, research, and statistics.

  15. Cystic duct closure by sealing with bipolar electrocoagulation

    DEFF Research Database (Denmark)

    Schulze, S; Damgaard, B; Jørgensen, Lars Nannestad

    2010-01-01

    BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed i...

  16. Magnetic resonance imaging of Muellerian duct anomalies in children

    International Nuclear Information System (INIS)

    Li, Yi; Phelps, Andrew; Zapala, Matthew A.; MacKenzie, John D.; MacKenzie, Tippi C.; Courtier, Jesse

    2016-01-01

    Muellerian duct anomalies encompass a wide variety of disorders resulting from abnormalities in the embryological development of the Muellerian ducts. In the prepubertal pediatric population, Muellerian duct anomalies are often incidental findings on studies obtained for other reasons. The onset of menses can prompt more clinical symptoms. Proper characterization of Muellerian duct anomalies is important because these anomalies can affect the development of gynecological disorders as well as fertility. Muellerian duct anomalies also carry a high association with other congenital anomalies, particularly renal abnormalities. MRI is widely considered the best modality for assessing Muellerian duct anomalies; it provides multiplanar capability, clear anatomical detail and tissue characterization without ionizing radiation. MRI allows for careful description of Muellerian duct anomalies, often leading to classification into the most widely accepted classification system for Muellerian duct anomalies. This system, developed by the American Society of Reproductive Medicine, includes seven subtypes: uterine agenesis/hypoplasia, unicornuate, didelphys, bicornuate, septate, arcuate, and diethylstilbestrol (DES) drug-related uterus. In cases of complex anomalies that defy classification, MRI allows detailed depiction of all components of the anatomical abnormality, allowing for proper management and surgical planning. (orig.)

  17. Surgical management of Stenson's duct injury using epidural catheter

    African Journals Online (AJOL)

    2012-07-05

    Jul 5, 2012 ... Successful management of parotid duct injury depends on early diagnosis and appropriate intervention, failing of ... to diagnose and manage the parotid duct injuries using an “epidural catheter” which is often used for inducing spinal anesthesia. .... Water-soluble contrast media have a definite advantage.

  18. Chloride and potassium conductances of cultured human sweat ducts

    DEFF Research Database (Denmark)

    Novak, I; Pedersen, P S; Larsen, Erik Hviid

    1992-01-01

    The purpose of this study was to characterize the ion conductances, in particular those for Cl- and K+, of human sweat duct cells grown in primary culture. Sweat duct cells from healthy individuals were grown to confluence on a dialysis membrane, which was then mounted in a mini-Ussing chamber an...

  19. Seismic assessment of the Pickering pressure relief duct

    International Nuclear Information System (INIS)

    Ghobarah, A.

    1995-05-01

    The objectives of the study are to examine the structural response of the Pickering pressure relief duct when subjected to earthquake ground motion and to estimate the seismic withstand capacity of various components of the structural system on the basis of performance criteria consistent with the safety function of the duct. (author). 24 refs., 16 tabs., 31 figs

  20. Transcatheter closure of ventricular septal defect with Occlutech Duct Occluder.

    Science.gov (United States)

    Atik-Ugan, Sezen; Saltik, Irfan Levent

    2018-04-01

    Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.

  1. Factors associated with post-ERCP pancreatitis and the effect of pancreatic duct stenting in a pediatric population.

    Science.gov (United States)

    Troendle, David M; Abraham, Omana; Huang, Rong; Barth, Bradley A

    2015-01-01

    Risk factors for the development of post-ERCP pancreatitis (PEP) have not been identified in the pediatric population. It remains unclear what constitutes appropriate prophylaxis in this patient population. To assess the prevalence and severity of PEP in the pediatric population and identify factors associated with developing PEP and to evaluate the effect of prophylactic pancreatic duct stenting in high-risk patients. Retrospective analysis of an ERCP database at a single large pediatric center. Academic center. A total of 432 ERCPs performed on 313 patients younger than 19 years of age from January 2004 to October 2013. ERCP for any indication. Rates and severity of PEP, preprocedural and procedural risk factors for the development of PEP, and the effect of pancreatic stents on preventing PEP in high-risk patients. PEP occurred after 47 procedures (prevalence, 10.9%). Thirty-four cases were mild, 9 were moderate, and 4 were severe. There was no mortality. On multiple logistic analysis, pancreatic duct injection (Ppancreatic sphincterotomy (Passociated with PEP. A history of chronic pancreatitis was negatively associated with PEP (Ppancreatic stent was associated with significantly increased rates of PEP in patients with pancreatic duct injection compared with those who had no attempt at stent placement (Ppancreatitis had prophylactic pancreatic stents in place. Retrospective investigation. In the pediatric population, pancreatic duct injection and pancreatic sphincterotomy are associated with significantly increased rates of PEP, whereas a history of chronic pancreatitis is negatively associated. Prophylactic pancreatic stenting is associated with higher rates of PEP in high-risk patients and does not eliminate severe PEP. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Experimental study and modelling of the well-mixing length. Application to the representativeness of sampling points in duct

    International Nuclear Information System (INIS)

    Alengry, Jonathan

    2014-01-01

    Monitoring of gaseous releases from nuclear installations in the environment and air cleaning efficiency measurement are based on regular measurements of concentrations of contaminants in outlet chimneys and ventilation systems. The concentration distribution may be heterogeneous at the measuring point if the distance setting of the mixing is not sufficient. The question is about the set up of the measuring point in duct and the error compared to the homogeneous concentration in case of non-compliance with this distance. This study defines the so-called 'well mixing length' from laboratory experiments. The bench designed for these tests allowed to reproduce flows in long circular and rectangular ducts, each including a bend. An optical measurement technique has been developed, calibrated and used to measure the concentration distribution of a tracer injected in the flow. The experimental results in cylindrical duct have validated an analytical model based on the convection-diffusion equation of a tracer, and allowed to propose models of good mixing length and representativeness of sampling points. In rectangular duct, the acquired measures constitute a first database on the evolution of the homogenization of a tracer, in the perspective of numerical simulations exploring more realistic conditions for measurements in situ. (author) [fr

  3. A Review of Double Common Bile Duct and Its Sequelae.

    Science.gov (United States)

    Kolli, Sindhura; Etienne, Denzil; Reddy, Madhavi; Shahzad, Ghulamullah

    2018-02-01

    A double or accessory common bile duct (ACBD) is a rare congenital anomaly. We report the case of a 60-year-old American Asian male, who was found to have a double or duplicated common bile duct after being admitted for evaluation of a pancreatic mass. A duplicated bile duct has the same mucosa histologically as a single bile duct. However, the opening of a duplicated bile duct lacks a sphincter allowing retrograde flow of gut contents which results in a higher probability of intraductal calculus formation. On rare occasions, it can predispose to liver abscesses, pancreatitis, pancreatic cancer, gallbladder cancer, gastric cancer, and ampullary cancer depending on the location of the opening of the ACBD. We present an integrative review of the limited cases of ACBD with correlation to the current case and discussion regarding the aspects of diagnosis and management.

  4. Cystic duct remnant mucocele in a liver transplant recipient

    Energy Technology Data Exchange (ETDEWEB)

    Ahlawat, Sushil K. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); University of Medicine and Dentistry of New Jersey, New Jersey Medical School, Newark, NJ (United States); Fishbien, Thomas M. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); Haddad, Nadim G. [Georgetown University Hospital, Department of Surgery, Division of Transplant Surgery, Washington, DC (United States)

    2008-08-15

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  5. Cystic duct remnant mucocele in a liver transplant recipient

    International Nuclear Information System (INIS)

    Ahlawat, Sushil K.; Fishbien, Thomas M.; Haddad, Nadim G.

    2008-01-01

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  6. Scintigraphy of cysts of the common bile duct in children

    International Nuclear Information System (INIS)

    Mironov, S.P.; Akopyan, V.G.; Murieva, Z.D.; Tumanyan, G.T.; Mironova, E.S.

    1984-01-01

    Cyst of the common bile duct, the most frequent variant of cystic dilatation of the extrahepatic biliary tract, represents a serious diagnostic problem. 13 children with cysts of the common bile duct were studied by the method of dynamic scintigraphy with sup(99m)Tc-HIDA. The scintigraphic picture was characterized by the following signs: sacculated or spheroidal dilatation of the common bile duct, dilatation of the left or both lobular bile ducts, absence of the gall bladder visualization. Change of indicators of the hepatic function and the time of interstinal visualization reflects both the disorder of distal parts permeability and the degree of cyst drainage. An experience of radioisotropic cholegraphy application reveals, that the efficiency of preoperational diagnosis of cysts of the common bile duct increases as a result of the more accurate evaluation of the dynamic of improvement of absorptive-excretory hepatic function after different variants of operations

  7. Consistent approach to air-cleaning system duct design

    International Nuclear Information System (INIS)

    Miller, W.H.; Ornberg, S.C.; Rooney, K.L.

    1981-01-01

    Nuclear power plant air-cleaning system effectiveness is dependent on the capability of a duct system to safely convey contaminated gas to a filtration unit and subsequently to a point of discharge. This paper presents a logical and consistent design approach for selecting sheet metal ductwork construction to meet applicable criteria. The differences in design engineers' duct construction specifications are acknowledged. Typical duct construction details and suggestions for their effective use are presented. Improvements in duct design sections of ANSI/ASME N509-80 are highlighted. A detailed leakage analysis of a control room HVAC system is undertaken to illustrate the effects of conceptual design variations on duct construction requirements. Shortcomings of previously published analyses and interpretations of a current standard are included

  8. Modeling Chronic Dacryocystitis in Rabbits by Nasolacrimal Duct Obstruction with Self-Curing Resin

    Directory of Open Access Journals (Sweden)

    Kai Hou

    2017-01-01

    Full Text Available We established a chronic dacryocystitis model by injecting of 0.05, 0.1, and 0.15 ml self-curing resin via the lacrimal punctum in rabbits. Animals were randomized into four groups (n=11 animals/group. The control group received 0.15 ml normal saline. Within three months postinjection, epiphora and eye discharge were observed. At the 90th day postlacrimal passage irrigation, CT dacryocystography was performed to find changes in the lacrimal image, and hematoxylin and eosin staining was made to identify pathological changes of the lacrimal sac. Three months postinjection, the rabbits in control group and those who received 0.05 and 0.1 ml self-curing resin failed to develop chronic dacryocystitis. However, 8/11 (72.7% rabbits those received 0.15 ml self-curing resin were symptomatic and showed complete reflux in lacrimal passage irrigation, indicating the obstruction of the nasolacrimal duct. CT dacryocystography showed that the obstruction was present only in the animals with chronic dacryocystitis. Pathological examinations of chronic dacryocystitis also revealed significantly inflammatory changes, such as mucus epithelium thickening, irregular papillary proliferation, and submucosal fibrous deposition. Local injection of 0.15 ml self-curing resin can induce permanent obstruction of the nasolacrimal duct in rabbits and establish a model of chronic dacryocystitis.

  9. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, B. [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-01

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  10. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, Robert [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, Bruce [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, Anthony [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, Ari [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-10

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  11. Self-retaining small-looped catheter for narrow bile ducts in high common bile duct obstruction

    International Nuclear Information System (INIS)

    Guenther, R.W.; Daehnert, W.

    1985-01-01

    A new self-retaining catheter was devised for percutaneous drainage of small bile ducts. The device allows safe external drainage without the risk of catheter dislocation even in high bile duct obstruction. The catheter is also suitable for percutaneous nephrostomy in non-dilated pyelocaliceal system. (orig.)

  12. Benign bile duct stenosis: diagnosis and treatment

    International Nuclear Information System (INIS)

    Garcia-Medina, J.; Casal, M.; Vieito, X.

    1997-01-01

    The bening injuries of the biliary ducts are relatively little frequent. Exist two groups of injuries: to due to them to a series for responsible pathologies for itself of the such injuries training, and that basically are the sclerosant cholangitis, the chronic pancreatitis and the stenosis of the sfinter of Oddi, and related them to previous surgery. On both groups eitological, the interventional radiology occupies a place in the diagnosis as well as in the treatment, complementing or substituting to the surgery. Due to the greater frequency of the postchirurgical injuries, we have centered us basically in them. We make a review of the current state of the topic and a bibliographical tracking, emphasizing the most relevant projects. We show some clinical cases of our subject-specific experience. (Author) 42 refs

  13. Large-scale CO2 injection demos for the development of monitoring and verification technology and guidelines (CO2ReMoVe)

    Energy Technology Data Exchange (ETDEWEB)

    Wildenborg, T.; David, P. [TNO Built Environment and Geosciences, Princetonlaan 6, 3584 CB Utrecht (Netherlands); Bentham, M.; Chadwick, A.; Kirk, K. [British Geological Survey, Kingsley Dunham Centre, Keyworth, Nottingham NG12 5GG (United Kingdom); Dillen, M. [SINTEF Petroleum Research, Trondheim (Norway); Groenenberg, H. [Unit Policy Studies, Energy Research Centre of the Netherlands ECN, Amsterdam (Netherlands); Deflandre, J.P.; Le Gallo, J. [Institut Francais du Petrole, Rueil-Malmaison (France)

    2009-04-15

    The objectives of the EU project CO2ReMoVe are to undertake the research and development necessary to establish scientifically based standards for monitoring future CCS operations and to develop the performance assessment methodologies necessary to demonstrate the long-term reliability of geological storage of CO2. This could in turn lead to guidelines for the certification of sites suitable for CCS on a wide scale. Crucial to the project portfolio are the continuing large-scale CO2 injection operation at Sleipner, the injection operation at In Salah (Algeria) and the recently started injection project at Snoehvit (Norway). Two pilot sites are also currently in the project portfolio, Ketzin in Germany and K12-B in the offshore continental shelf of the Netherlands.

  14. Experiments and calculations on neutron streaming through bent ducts

    Energy Technology Data Exchange (ETDEWEB)

    Kloosterman, J.L.; Hoogenboom, J.E. (Delft Univ. of Technology (Netherlands). Interfaculty Reactor Inst.); Zsolnay, E.M.

    1993-07-01

    Neutron spectra in a cylindrical straight duct and in bent ducts with angles of 30deg, 60deg and 90deg have been measured by the multiple foil activation and thermoluminescence dosimetry methods. Two-dimensional discrete ordinates and three-dimensional Monte Carlo calculations are executed, and the results are compared with the measurements. The flow rate at the duct entrance calculated by the DOT3.5 code is underestimated by approximately 30 %, due to a conversion of the core and reflector geometry from XY to RZ geometry. The fast neutron flux in the ducts is underestimated by 20 % by the MORSE-SGC/S code due to a too coarse angular mesh of the source, which does not properly represent the actual angular distribution of the fast flux, which is highly peaked forwardly into the ducts. The thermal neutron flux was over-estimated by the Monte Carlo calculation. A method is proposed to calculate the angular distribution of the flow rate at the duct entrance and to calculate the source strength and the angular distribution of the flow rate at the entrance of the second leg of the duct. The results are compared with those of the transport calculations. Generally, the agreement is quite satisfactory. (author).

  15. Water condensation promotes fungal growth in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Pasanen, P.; Pasanen, A.-L. (University of Kupopio, Department of Environmental Sciences, Kuopio (Finland)); Jantunen, M. (National Public Health Institute, Kuopio (Finland))

    1993-01-01

    In a subarctic climate the diurnal variation in temperature may cause water condensation in ducts placed in the unheated spaces of a building. In this study, germination time and sporulation of a fungus, Penicillium verrucosum, were studied on dusty, galvanized steel sheet under different moisture conditions at room temperature. The effect of condensed water in a supply air duct on spore amplification was studied in an experimental ventilation set-up. In the field, air temperatures and the dew point temperature of air in the duct were monitored continuously for a week. P. verrucosum germinated on steel surfaces during five-hour incubation of the surface under humid conditions, when the surface has been moist for half an hour, germ tubes appeared within 17 hours. During 24-hour incubation under moist conditions, P. verrucosum produced hyphae and spores. In the experimental set-up the airborne spore counts increased when the air passed through a water-condensing section of the duct. Penicillium was the most abundant fungus sporulated on the moist duct surface. In the field, during humid weather, the surface temperature on the air stream surface decreased to the dew point temperature of the air in the duct. thus water condensation in air ducts may promote fungal growth. (au)

  16. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    Science.gov (United States)

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  17. Chronic bile duct hyperplasia is a chronic graft dysfunction following liver transplantation.

    Science.gov (United States)

    Jiang, Jian-Wen; Ren, Zhi-Gang; Cui, Guang-Ying; Zhang, Zhao; Xie, Hai-Yang; Zhou, Lin

    2012-03-14

    To investigate pathological types and influential factors of chronic graft dysfunction (CGD) following liver transplantation (LT) in rats. The whole experiment was divided into three groups: (1) normal group (n = 12): normal BN rats without any drug or operation; (2) syngeneic transplant group (SGT of BN-BN, n = 12): both donors and recipients were BN rats; and (3) allogeneic transplant group (AGT of LEW-BN, n = 12): Donors were Lewis and recipients were BN rats. In the AGT group, all recipients were subcutaneously injected by Cyclosporin A after LT. Survival time was observed for 1 year. All the dying rats were sampled, biliary tract tissues were performed bacterial culture and liver tissues for histological study. Twenty-one day after LT, 8 rats were selected randomly in each group for sampling. Blood samples from caudal veins were collected for measurements of plasma endotoxin, cytokines and metabonomic analysis, and faeces were analyzed for intestinal microflora. During the surgery of LT, no complications of blood vessels or bile duct happened, and all rats in each group were still alive in the next 2 wk. The long term observation revealed that a total of 8 rats in the SGT and AGT groups died of hepatic graft diseases, 5 rats in which died of chronic bile duct hyperplasia. Compared to the SGT and normal groups, survival ratio of rats significantly decreased in the AGT group (P liver necrosis, liver infection, and severe chronic bile duct hyperplasia were observed in the AGT group by H and E stain. On 21 d after LT, compared with the normal group (25.38 ± 7.09 ng/L) and SGT group (33.12 ± 10.26 ng/L), plasma endotoxin in the AGT group was remarkably increased (142.86 ± 30.85 ng/L) (both P bile duct tissues revealed that the rats close to death from the SGT and AGT groups were strongly positive, while those from the normal group were negative. The analysis of intestinal microflora was performed. Compared to the normal group (7.98 ± 0.92, 8.90 ± 1.44) and SGT

  18. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  19. The correlation between the dilated extent of bile duct and gallbladder and low bile duct obstructive jaundice diseases

    International Nuclear Information System (INIS)

    Wang Zhongqiu; Lu Guangming; Li Jieshou; Li Weiqin

    2005-01-01

    Objective: To evaluate the diagnostic value about the dilated extent of bile duct and gallbladder in low biliary obstructive diseases. Methods: CT and ERCP findings of 105 patients with low biliary obstructive disease were retrospectively analyzed. The dilated extent of intrahepatic and extra- hepatic bile duct and gallbladder were classified into seven types: Type I: severe dilatation of intrahepatic and extrahepatic bile duct and gallbladder; Type II: severe dilatation of extrahepatic bile duct and gallbladder and slight dilated intrahapetic bile duct; Type III: severe dilatation of intrahepatic and extrahepatic bile duct without or slight dilatation of gallbladder; Type IV: severe extrahepatic bile duct dilatation without or slight dilatation of intrahepatic bile duct and gallbladder; Type V: severe intrahepatic bile duct dilatation without or with slight dilatation of extrahepatic bile duct and gallbladder; Type VI: severe gallbladder dilatation without or with slight intrahepatic and extra- hepatic bile duct dilatation; Type VII: without or with slight dilatation of intrahepatic and extrahepatic bile duct and gallbladder. The biliary system dilated extent of low biliary obstructive disease on CT and ERCP were compared with results of clinical, operation, and pathology. Results: Thirty-three cases of tumor and 72 cases of non-tumor were proved by clinical and operation in 105 patients with low biliary obstructive disease. In 33 tumor patients, 16 patients were identified as Type I, 10 patients Type II, 4 patients Type III, 1 patient Type IV, 2 patients Type VII. In 72 non-tumor patients, 4 patients were identified as Type I, 4 patients Type II, 9 patients Type III, 33 patients Type IV, 2 patients Type V, 11 patients Type VI, 19 patients Type VII. A large difference between I, II type and III-VII type biliary dilatation existed in tumor and non-tumor group (χ 2 =47.33, P<0.01). Conclusion:Low obstructive biliary diseases are closely correlated with the dilated

  20. Effects of explosion-generated shock waves in ducts

    International Nuclear Information System (INIS)

    Busby, M.R.; Kahn, J.E.; Belk, J.P.

    1976-01-01

    An explosion in a space causes an increase in temperature and pressure. To quantify the challenge that will be presented to essential components in a ventilation system, it is necessary to analyze the dynamics of a shock wave generated by an explosion, with attention directed to the propagation of such a wave in a duct. Using the equations of unsteady flow and shock tube theory, a theoretical model has been formulated to provide flow properties behind moving shock waves that have interacted with various changes in duct geometry. Empirical equations have been derived to calculate air pressure, temperature, Mach number, and velocity in a duct following an explosion

  1. Preoperative intraluminal irradiation of the extrahepatic bile duct tumor

    International Nuclear Information System (INIS)

    Kamada, Tadashi; Tsujii, Hirohiko; Arimoto, Takuro; Irie, Goro.

    1991-01-01

    From 1984 through 1986, six patients with extrahepatic bile duct tumor were treated preoperatively with intraluminal irradiation of the bile duct. There were no unresectable cases and pathological examination of the surgical specimens showed moderate to remarkable tumor regression in all cases. Postoperative biliary tract hemorrhage occurred in 2 of 3 patients who received 60 Gy at a point 7.5 mm from the center of the source. With accurate preoperative diagnosis of the tumor extent and careful setting of the target area of intraluminal irradiation, improved local tumor control of extrahepatic bile duct tumor can be expected with this method. (author)

  2. BACTERIOLOGICAL INVESTIGATION ON Fasciola hepatica AND CATTLE BILIARY DUCTS

    Directory of Open Access Journals (Sweden)

    A. Panebianco

    2009-03-01

    Full Text Available The aim of this work was to investigate the occurrence of bacteria in Fasciola hepatica and into cattle biliary ducts containing the parasite. A total of 24 liver and 58 F. hepatica samples were analysed. In all biliary ducts and in 62,06% of parasite Enterobacteriaceae were isolated. The bacterial specie more frequently isolated from parasite were Citrobacter freundii (34%, Proteus mirabilis (18%, Providencia rettgeri (12%, Staphylococcus spp. (18%, Enterobacter spp. (12%. There doesn’t appear to be a correlation between bacterial specie from parasite and ducts. The Authors conclude with some related inspective consideration.

  3. A remote joint system for large vacuum ducts

    International Nuclear Information System (INIS)

    Hagmann, D.B.; Coughlan, J.B.

    1983-01-01

    A large remote vacuum duct joining system has been developed for fusion machines that uses several two-jaw screwdriven clamps. The preferred location for clamp installation is inside the vacuum duct where access space is available for the actuating device. It also decreases space needed for handling operations exterior to the duct. The clamp system is unique in that it is low cost, applies force directly over the seal, permits leak testing to the seal annulus, is highly reliable, can be remotely replaced, and is usable on a variety of other applications

  4. Pure 3D laparoscopic living donor right hemihepatectomy in a donor with separate right posterior and right anterior hepatic ducts and portal veins.

    Science.gov (United States)

    Hong, Suk Kyun; Suh, Kyung-Suk; Kim, Hyo-Sin; Yoon, Kyung Chul; Ahn, Sung-Woo; Oh, Dongkyu; Kim, Hyeyoung; Yi, Nam-Joon; Lee, Kwang-Woong

    2017-11-01

    Despite increases in the performance of pure laparoscopic living donor hepatectomy, variations in the bile duct or portal vein have been regarded as relative contraindications to this technique [1-3]. This report describes a donor with separate right posterior and right anterior hepatic ducts and portal veins who underwent pure laparoscopic living donor right hemihepatectomy, integrated with 3D laparoscopy and indocyanine green (ICG) near-infrared fluorescence cholangiography [1, 4, 5]. A 50-year-old man offered to donate part of his liver to his older brother, who required a transplant for hepatitis B-associated liver cirrhosis and hepatocellular carcinoma. Donor height was 178.0 cm, body weight was 82.7 kg, and body mass index was 26.1 kg/m 2 . Preoperative computed tomography and magnetic resonance cholangiopancreatography showed that the donor had separate right posterior and right anterior hepatic ducts and portal veins. The entire procedure was performed under 3D laparoscopic view. Following intravenous injections of 0.05 mg/kg ICG, ICG near-infrared fluorescence camera was used to demarcate the exact transection line and determine the optimal bile duct division point. The total operation time was 443 min; the donor required no transfusions and experienced no intraoperative complications. The graft weighed 1146 g with a graft-to-recipient weight ratio of 1.88%. The optimal bile duct division point was identified using ICG fluorescence cholangiography, and the bile duct was divided with good patency without any stricture. The right anterior and posterior portal veins were transected with endostaplers without any torsion. The patient was discharged on postoperative day 8, with no complications. Using a 3D view and ICG fluorescence cholangiography, pure 3D laparoscopic living donor right hemihepatectomy is feasible in a donor with separate right posterior and right anterior hepatic ducts and portal veins.

  5. Strengthening of bridges by post-tensioning using monostrands in substituted cable ducts

    Science.gov (United States)

    Klusáček, Ladislav; Svoboda, Adam

    2017-09-01

    Post-tensioning is suitable, reliable and durable method of strengthening existing engineering structures, especially bridges. The high efficiency of post-tensioning can be seen in many applications throughout the world. In this paper the method is extended by a structural system of substituted cable ducts, which allows for significantly widening application of prestressing so it’s convenient mostly for application on beam bridges or slab bridges (built in years 1920 - 1960). The method of substituted cable ducts is based on theoretical knowledge and technical procedures, which were made possible through the development in prestressing systems, particularly the development of prestressing tendons (monostrands) and encased anchorages, as well as progress in drilling technology. This technique is highly recommended due to minimization of interventions into the constructions, unseen method of cable arrangement and hence the absence of impact on appearance, which is appreciated not only in case of valuable historical structures but also in general. It is possible to summarise that posttensioning by monostrands in substituted cable ducts is a highly effective method of strengthening existing bridges in order to increase their load capacities in terms of current traffic load and to extend their service life.

  6. Research cooperation project on the development of easy injection molding control technology for engineering plastics; Engineering plastic no seikei joken kan`i settei gijutsu ni kansuru kenkyu kyoryoku jigyo seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    In order to enhance the industries which supply assembly parts to Japan`s assembly industries in Thailand, research cooperation project on the plastic parts production technology has started. For the research cooperation, the mold design is effectively conducted using simulation technique of CAE (computer aided engineering), and an international easy injection molding control system is made using the molding support software for injection molding machines. In FY 1996, actual situations of plastic parts and assembly industries in Thailand have been investigated through the cooperation with the counterpart of Thailand. Demand and supply of engineering plastics, receive and inspection of parts, and current circumstances of molding processing makers in Thailand have been grasped. Based on the results of this investigation, proposal of basic plan, time schedule, and delivery plan of molding machines and testing equipment have been discussed, to make the basic plan. 18 refs., 4 figs., 23 tabs.

  7. Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version

    Science.gov (United States)

    Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.

  8. Bile Duct Cancer (Cholangiocarcinoma) Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version

    Science.gov (United States)

    Bile duct cancer, or cholangiocarcinoma, is rare. Bile ducts are tubes that carry bile between the liver, gallbladder, and small intestine. Bile duct cancer can occur in the intrahepatic, perihilar (Klatskin tumor), or distal extrahepatic area. Learn about tests to diagnose and the stages of bile duct cancer.

  9. ß-adrenergic regulation of ion transport in pancreatic ducts: Patch-clamp study of isolated rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I

    1998-01-01

    BACKGROUND & AIMS: In the intact pancreas, bicarbonate secretion is thought to be controlled by a number of regulators, including adrenergic agonists. The aim of this study was to investigate the effects of adrenergic agonists on pancreatic ducts, which are the site of bicarbonate secretion....... METHODS: Small intralobular ducts were isolated from rat pancreas and studied in vitro by the whole-cell patch clamp technique. Cell membrane voltages and currents were indicators of cellular ion transport. In some ducts, intracellular Ca2+ activity was measured by fluorescence optical methods. RESULTS...

  10. Status of the development of hot gas ducts for HTRs

    International Nuclear Information System (INIS)

    Stehle, H.; Klas, E.

    1984-01-01

    In the PNP nuclear process heat system the heat generated in the helium cooled core is transferred to the steam reformer and to the successive steam generator or to the intermediate heat exchanger by the primary helium via suitable hot gas ducts. The heat is carried over to the steam gasifier by the intermediate heat exchanger and a secondary helium loop. In both the primary and the secondary loop, the hot gas ducts are internally insulated by a ceramic fibre insulation to protect the support tube and the pressure housing from the high helium temperatures. A graphite hot gas liner will be used for the coaxial primary duct with an annular gap between support tube and pressure shell for the cold gas counterflow. A metallic hot gas liner will be installed in the secondary duct

  11. Improvement in the management of bile duct injuries?

    NARCIS (Netherlands)

    Keulemans, Y. C.; Bergman, J. J.; de Wit, L. T.; Rauws, E. A.; Huibregtse, K.; Tytgat, G. N.; Gouma, D. J.

    1998-01-01

    BACKGROUND: Previous studies have suggested that improvements in diagnostic workup and treatment of bile duct injuries (BDI) sustained during laparoscopic cholecystectomy can be expected as experience increases with the laparoscopic procedure. Many published articles reported that early diagnosis,

  12. Design requirement on KALIMER control rod assembly duct

    International Nuclear Information System (INIS)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J.

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs

  13. Design requirement on KALIMER control rod assembly duct

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs.

  14. Spontaneous common bile duct perforation—A rare clinical entity

    Directory of Open Access Journals (Sweden)

    Melissa Amberger

    Full Text Available Introduction: Spontaneous common bile duct perforation is an uncommon clinical entity in both adults and children. Few case reports have been published since the first clinical description in 1882. Our work has been reported in line with SCARE criteria. Presentation of case: Herein, we describe the case of a 28 year-old female who suffered spontaneous common bile duct perforation while admitted for choledocholithiasis. Discussion: The perforation occurred while in-hospital, and extensive imaging and laboratory tests characterized the disease in detail. To our knowledge, this is the first report of spontaneous common bile duct perforation witnessed from pre-perforation through definitive management. Conclusion: Physicians and Surgeons should seek out this uncommon diagnosis in the patient with suspected Choledocholithiasis who suddenly become peritoneal on physical exam so that definitive care can be expedited. Keywords: Common bile duct, Biliary peritonitis, Choledocholithiasis

  15. Heuristic approach to the passive optical network with fibre duct ...

    African Journals Online (AJOL)

    Integer programming, network flow optimisation, passive optical network, ... This paper uses concepts from network flow optimisation to incorporate fibre duct shar ... [4] studied the survivable constrained ConFL problem and solved a number of.

  16. Bile Duct Obstruction Secondary to Chronic Pancreatitis in Seven Dogs

    OpenAIRE

    Cribb, Alastair E.; Burgener, David C.; Reimann, Keith A.

    1988-01-01

    Seven icteric dogs were determined to have bile duct obstruction secondary to chronic pancreatitis. All dogs had histories of intermittent vomiting and diarrhea. Alkaline phosphatase and alanine aminotransferase activities and total bilirubin concentrations were markedly elevated. Diagnosis was based on exploratory laparotomy and histological examination. Each dog had a 3 to 10 cm mass in the body of the pancreas and obstruction of the common bile duct. Three dogs treated with pancreatectomy,...

  17. Studying the sampling representativeness in the NPP ventilation ducts

    International Nuclear Information System (INIS)

    Sosnovskij, R.I.; Fedchenko, T.K.; Minin, S.A.

    2000-01-01

    Measurements of the gas and aerosol voluminous activity in the NPP ventilation ducts are an important source of information on the radiation contaminants ingress into the environmental medium. These measurements include sampling, samples transport and proper measurements. The work is devoted to calculation of metrological characteristics of the sampling systems for the NPP gas-aerosol releases by different parameters of these systems and ventilation ducts. The results obtained are intended for application by designing such systems and their metrological certification [ru

  18. Endoscopic stenting in bile duct cancer increases liver volume.

    Science.gov (United States)

    Lee, Chang Hun; Kim, Seong Hun; Kim, In Hee; Kim, Sang Wook; Lee, Soo Teik; Kim, Dae Ghon; Yang, Jae Do; Yu, Hee Chul; Cho, Baik Hwan; Lee, Seung Ok

    2014-09-01

    Objective evaluation tools for assessing the effectiveness of stenting in palliative treatment of malignant biliary obstruction are not satisfactory. Effects of biliary stenting on liver volume change have never been studied. We aimed to use volumetry to analyze liver volume changes after endoscopic stenting in bile duct cancer according to the location and number of stents. Retrospective review. University hospital. Patients with a diagnosis of hilar or distal bile duct cancer and who underwent biliary metal stenting. ERCP with self-expandable metal stent placement. Liver volume change after biliary stenting and its comparison according to the location (hilar vs distal common bile duct) and number (hilar bilateral vs hilar unilateral). There were 60 patients; 31 were treated for hilar bile duct cancer (13 for bilateral stent and 18 for unilateral stent) and 29 for distal bile duct cancer. Overall mean follow-up duration was 11.7 ± 4.9 weeks. Liver volume increased 17.4 ± 24.1%. The rate of liver growth was rapid during the early period from 4 to 8 weeks. Stenting in hilar bile duct cancer tended to increase liver volume more than distal biliary stents (22.5% vs 11.9%, P = .091). In hilar bile duct cancer, unilateral and bilateral stents showed similar liver volume increases (20.1% and 25.8%, respectively; P = .512). Single center, retrospective. Biliary stenting markedly increased liver volume in both hilar and distal bile duct cancer. Our data suggest that liver volume assessment could be a useful tool for evaluating stent efficacy. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  19. Surgical versus endoscopic treatment of bile duct stones

    DEFF Research Database (Denmark)

    Martin, D J; Vernon, D R; Toouli, J

    2006-01-01

    10% to 18% of patients undergoing cholecystectomy for gallstones have common bile duct (CBD) stones. Treatment options for these stones include pre- or post-operative endoscopic retrograde cholangiopancreatography (ERCP) or open or laparoscopic surgery.......10% to 18% of patients undergoing cholecystectomy for gallstones have common bile duct (CBD) stones. Treatment options for these stones include pre- or post-operative endoscopic retrograde cholangiopancreatography (ERCP) or open or laparoscopic surgery....

  20. Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D. [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-01

    A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval.

  1. BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS,J.

    2001-01-01

    This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.

  2. Near-Infrared Spectroscopy as an Analytical Process Technology for the On-Line Quantification of Water Precipitation Processes during Danhong Injection

    Directory of Open Access Journals (Sweden)

    Xuesong Liu

    2015-01-01

    Full Text Available This paper used near-infrared (NIR spectroscopy for the on-line quantitative monitoring of water precipitation during Danhong injection. For these NIR measurements, two fiber optic probes designed to transmit NIR radiation through a 2 mm flow cell were used to collect spectra in real-time. Partial least squares regression (PLSR was developed as the preferred chemometrics quantitative analysis of the critical intermediate qualities: the danshensu (DSS, (R-3, 4-dihydroxyphenyllactic acid, protocatechuic aldehyde (PA, rosmarinic acid (RA, and salvianolic acid B (SAB concentrations. Optimized PLSR models were successfully built and used for on-line detecting of the concentrations of DSS, PA, RA, and SAB of water precipitation during Danhong injection. Besides, the information of DSS, PA, RA, and SAB concentrations would be instantly fed back to site technical personnel for control and adjustment timely. The verification experiments determined that the predicted values agreed with the actual homologic value.

  3. Near-Infrared Spectroscopy as an Analytical Process Technology for the On-Line Quantification of Water Precipitation Processes during Danhong Injection.

    Science.gov (United States)

    Liu, Xuesong; Wu, Chunyan; Geng, Shu; Jin, Ye; Luan, Lianjun; Chen, Yong; Wu, Yongjiang

    2015-01-01

    This paper used near-infrared (NIR) spectroscopy for the on-line quantitative monitoring of water precipitation during Danhong injection. For these NIR measurements, two fiber optic probes designed to transmit NIR radiation through a 2 mm flow cell were used to collect spectra in real-time. Partial least squares regression (PLSR) was developed as the preferred chemometrics quantitative analysis of the critical intermediate qualities: the danshensu (DSS, (R)-3, 4-dihydroxyphenyllactic acid), protocatechuic aldehyde (PA), rosmarinic acid (RA), and salvianolic acid B (SAB) concentrations. Optimized PLSR models were successfully built and used for on-line detecting of the concentrations of DSS, PA, RA, and SAB of water precipitation during Danhong injection. Besides, the information of DSS, PA, RA, and SAB concentrations would be instantly fed back to site technical personnel for control and adjustment timely. The verification experiments determined that the predicted values agreed with the actual homologic value.

  4. Alloy development for cladding and duct applications

    International Nuclear Information System (INIS)

    Straalsund, J.L.; Johnson, G.D.

    1981-01-01

    Three general classes of materials under development for cladding and ducts are listed. Solid solution strengthened, or austenitic, alloys are Type 316 stainless steel and D9. Precipitation hardened (also austenitic) alloys consist of D21, D66 and D68. These alloys are similar to such commercial alloys as M-813, Inconel 706, Inconel 718 and Nimonic PE-16. The third general class of alloys is composed of ferritic alloys, with current emphasis being placed on HT-9, a tempered martensitic alloy, and D67, a delta-ferritic steel. The program is comprised of three parallel paths. The current reference, or first generation alloy, is 20% cold worked Type 316 stainless steel. Second generation alloys for near-term applications include D9 and HT-9. Third generation materials consist of the precipitation strengthened steels and ferritic alloys, and are being considered for implementation at a later time than the first and second generation alloys. The development of second and third generation materials was initiated in 1974 with the selection of 35 alloys. This program has proceeded to today where there are six advanced alloys being evaluated. These alloys are the developmental alloys D9, D21, D57, D66 and D68, together with the commerical alloy, HT-9. The status of development of these alloys is summarized

  5. WAVE PROPAGATION in the HOT DUCT of VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Richard Schultz; Jim C. P. Liou

    2013-07-01

    In VHTR, helium from the reactor vessel is conveyed to a power conversion unit through a hot duct. In a hypothesized Depressurized Conduction Cooldown event where a rupture of the hot duct occurs, pressure waves will be initiated and reverberate in the hot duct. A numerical model is developed to quantify the transients and the helium mass flux through the rupture for such events. The flow path of the helium forms a closed loop but only the hot duct is modeled in this study. The lower plum of the reactor vessel and the steam generator are treated as specified pressure and/or temperature boundary to the hot duct. The model is based on the conservation principles of mass, momentum and energy, and on the equations of state for helium. The numerical solution is based on the method of characteristics with specified time intervals with a predictor and corrector algorithm. The rupture sub-model gives reasonable results. Transients induced by ruptures with break area equaling 20%, 10%, and 5% of the duct cross-sectional area are described.

  6. A non-local computational boundary condition for duct acoustics

    Science.gov (United States)

    Zorumski, William E.; Watson, Willie R.; Hodge, Steve L.

    1994-01-01

    A non-local boundary condition is formulated for acoustic waves in ducts without flow. The ducts are two dimensional with constant area, but with variable impedance wall lining. Extension of the formulation to three dimensional and variable area ducts is straightforward in principle, but requires significantly more computation. The boundary condition simulates a nonreflecting wave field in an infinite duct. It is implemented by a constant matrix operator which is applied at the boundary of the computational domain. An efficient computational solution scheme is developed which allows calculations for high frequencies and long duct lengths. This computational solution utilizes the boundary condition to limit the computational space while preserving the radiation boundary condition. The boundary condition is tested for several sources. It is demonstrated that the boundary condition can be applied close to the sound sources, rendering the computational domain small. Computational solutions with the new non-local boundary condition are shown to be consistent with the known solutions for nonreflecting wavefields in an infinite uniform duct.

  7. Conservative Treatment for Cystic Duct Stenosis in a Child

    Directory of Open Access Journals (Sweden)

    Marco Gasparetto

    2013-01-01

    Full Text Available Introduction. Few cases of common bile duct stenosis have been reported in the literature, and observations of strictures in the cystic duct are even more rare. Surgical cholecystectomy is the treatment needed in most cases of gallbladder hydrops. This paper describes the diagnosis and successful medical treatment of a rare pediatric case of cystic duct stenosis and gallbladder hydrops. Case Report. A formerly healthy one-year-old girl was admitted with colicky abdominal pain. Blood tests were normal, except for an increase in transaminases. Abdominal ultrasound excluded intestinal intussusception and identified a distended gallbladder with biliary sludge. MR cholangiography revealed a dilated gallbladder containing bile sediment and no detectable cystic duct, while the rest of the intra- and extrahepatic biliary tree and hepatic parenchyma were normal. This evidence was consistent with gallbladder hydrops associated with cystic duct stenosis. The baby was treated with i.v. hydration, corticosteroids, antibiotics, and ursodeoxycholic acid. Her general condition rapidly improved, with no further episodes of abdominal pain and normalization of liver enzymes. This allowed to avoid cholecystectomy, and the child is well 1.5 years after diagnosis. Conclusions. Although cholecystectomy is usually necessary in case of gallbladder hydrops, our experience suggests that surgical procedures can be avoided when the distension is caused by a cystic duct stenosis.

  8. Parotid duct laceration repair in two horses : case report

    Directory of Open Access Journals (Sweden)

    A. Olivier

    1998-07-01

    Full Text Available Repair of parotid duct lacerations in 2 horses is described using intraluminal silastic tubing as a stent. The duct was lacerated traumatically at the facial vessel notch (incisura vasorum facialium in the 1st horse, and iatrogenically after removal of an intraluminal sialolith after development of infection within the duct in the 2nd horse. In both cases, a silastic tube was passed retrograde into the duct via the salivary papilla, past the wound until the end lay rostroventral to the parotid salivary gland. The severed salivary ducts and the wounds were sutured. The external portion of the silastic tube was sutured to the skin and the tube left in place. Recovery in the 1st case was uneventful. In the 2nd case a salivary duct/cutaneous fistula formed at a wound distant from the sutured wound, which healed spontaneously. This technique differs from a similar described technique in that the stent tube exits the oral cavity and is attached to the outer skin surface.

  9. Thermal performance test of the hot gas ducts of HENDEL

    International Nuclear Information System (INIS)

    Hishida, M.; Kunitomi, K.; Ioka, I.; Umenishi, K.; Tanaka, T.; Shimomura, H.; Sanokawa, K.

    1984-01-01

    A hot gas duct provided with internal thermal insulation is to be used for high-temperature gas-cooled reactors (HTGR). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of a hot gas duct have been conducted. The present report deals with the results of the thermal performance of the single tube type hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL). Uniform temperature and heat flux distribution at the surface of the duct were observed, the experimental correlations being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of the co-axial hot gas duct was evaluated and no hot spot was detected. These results would be very valuable for the design and development of HTGR. (orig.)

  10. AISI/DOE Technology Roadmap Program: Removal of Residual Elements in The Steel Ladle by a Combination of Top Slag and Deep Injection Practice

    Energy Technology Data Exchange (ETDEWEB)

    S. Street; K.S. Coley; G.A. Iron

    2001-08-31

    The objective of this work was to determine if tin could be removed from liquid steel by a combination of deep injection of calcium and a reducing top-slag practice. The work was carried out in three stages: injection of Ca wire into 35 Kg heats in an induction furnace under laboratory condition; a fundamental study of the solubility of Sn in the slag as a function of oxygen potential, temperature and slag composition; and, two full-scale plant trials. During the first stage, it was found that 7 to 50% of the Sn was removed from initial Sn contents of 0.1%, using 8 to 16 Kg of calcium per tonne of steel. The Sn solubility study suggested that low oxygen potential, high basicity of the slag and lower temperature would aid Sn removal by deep injection of Ca in the bath. However, two full-scale trials at the LMF station in Dofasco's plant showed virtually no Sn removal, mainly because of very low Ca consumption rates used (0.5 to 1.1 Kg/tonne vs. 8 to 16 Kg/tonne used during the induction furnace study in the laboratory). Based on the current price of Ca, addition of 8 to 16 Kg/tonne of steel to remove Sn is too cost prohibitive, and therefore, it is not worthwhile to pursue this process further, even though it may be technically feasible.

  11. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D. [BA-PIRC, Cocoa, FL (United States); McIlvaine, J. [BA-PIRC, Cocoa, FL (United States); Fonorow, K. [BA-PIRC, Cocoa, FL (United States); Martin, E. [BA-PIRC, Cocoa, FL (United States)

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces.

  12. Ultrasound versus liver function tests for diagnosis of common bile duct stones.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Giljaca, Vanja; Takwoingi, Yemisi; Higgie, David; Poropat, Goran; Štimac, Davor; Davidson, Brian R

    2015-02-26

    Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. Two authors independently collected data from

  13. Prototype demonstration of dual sorbent injection for acid gas control on municipal solid waste combustion units

    Energy Technology Data Exchange (ETDEWEB)

    None

    1994-05-01

    This report gathered and evaluated emissions and operations data associated with furnace injection of dry hydrated lime and duct injection of dry sodium bicarbonate at a commercial, 1500 ton per day, waste-to-energy facility. The information compiled during the project sheds light on these sorbents to affect acid gas emissions from municipal solid waste combustors. The information assesses the capability of these systems to meet the 1990 Clean Air Act and 1991 EPA Emission Guidelines.

  14. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  15. Imaging features of intraductal papillary neoplasm of the bile duct

    International Nuclear Information System (INIS)

    Liu Yubao; Li Meng; Zhong Xiaomei; Liu Zaiyi; Liang Changhong

    2014-01-01

    Objective: To investigate the CT and MRI features of intraductal papillary neoplasm of the bile duct (IPNB). Methods: Thirty eight patients with IPNB finally diagnosed by puncture biopsy or surgery were enrolled in this study. All the CT or MRI data were investigated retrospectively. Twenty one patients underwent CT examinations, 17 patients underwent MRI examinations. The features of IPNB including the distribution features of the nodules or masses, CT and MRI features of cholangiectasis, mucus were analyzed. The accuracy differences of CT and MRI for the preoperatively diagnosing mucus and tumor growing along mucous were compared by nonparametric test. Results: The lesions (including 5 patients with solitary lesions and 19 patients with multiple lesions) were located in intrahepatic bile duct in 24 patients, 3 patients occurred simultaneously in intrahepatic and portal bile duct, 2 lesions occurred in portal bile duct, 8 lesions occurred in common bile duct, the lesions of 1 patient occurred simultaneously in common bile duct, cystic duct and gallbladder. Seventeen and 11 patients appeared nodules locating in dilated bile duct on CT and MRI, respectively. Four and 5 patients appeared cystic lesions with multiple nodules of the liver on CT and MRI, respectively. Higher contrast enhancement on CT and MRI in arterial phase than that in portal vein and equilibrium phase were observed in 18 and 12 patients, respectively. Excluding the patients undergoing puncture, CT was better than MRI in evaluating whether the mucus was present, with the accuracies of 30.0% (6/20) and 6.3% (1/16) for CT and MRI, respectively (Z=2.58, P<0.05). CT was worse than MRI in preoperatively evaluating the features of tumor growing along mucous, with the accuracies of 77.8% (14/18) and 92.6% (13/14) for CT and MRI, respectively (Z=4.23, P<0.01). Conclusion: IPNB had the features of growing along mucous of the bile duct, nodule or mass in dilated bile duct and other features, CT and MRI are

  16. An incidence study on thyroglossal duct cysts in adults

    International Nuclear Information System (INIS)

    Kurt, A.; Ortug, C.; Aydar, Y.; Ortug, G.

    2007-01-01

    To investigate the incidence of the asymptomatic thyroglossal duct anomalies and to review the literature and make comments on the significance of this condition. A total of 80 cadavers were dissected in the present study. This study was carried out during 2005, where the cadavers were randomly included from the criminal laboratories of the Ministry of Justice, Republic of Turkey in Istanbul. None of the cadavers had laryngeal and cervical injuries resulting from a trauma or the cause of their death. The examined cadavers included 59 men and 21 females, and their ages were ranged from 35-80 years old. The larynges were removed and fixed in 10% formalin and then dissected. The sections were examined using surgical SMZ 10 Nikon stereomicroscope. We evaluated the presence, localization and diameter of the cysts with regard to age and sex of the cadavers. We observed a total of 12 different localization of thyroglossal ducts and cysts among the 80 dissected cadavers. Ten of these ducts cysts were found in males with an age range of 35-68 years and 2 female cadavers aged 45-65 years. In 6 cases, the thyroglossal ducts and cysts were located in the left of the midline of the neck, while 3 cases were from the right of the midline, and the remaining was located on the midline of the neck. In all cases, thryoglossal ducts and cysts were complete and restricted to the infrahyoid region: all of them had connection with the hyoid bone, but not with the perichondrium of the cartilage. In addition, the thyroglossal ducts have connection with the left lobe of the thyroid glands in 3 cases, one case in the right lobe, and 2 cases with the isthmus of the thyroid gland. Finally in 5 cases thyroglossal ducts were complete and had well developed cysts. Thyroglossal duct remnants are one of the most often seen congenital asymptomatic masses of the neck region (7%). The presence of these duct remnants may lead to abnormal phonation and epithelial carcinomas. Therefore, correlation of

  17. Development of resistance to serotonin-induced itch in bile duct ligated mice.

    Science.gov (United States)

    Ostadhadi, Sattar; Haddadi, Nazgol-Sadat; Foroutan, Arash; Azimi, Ehsan; Elmariah, Sarina; Dehpour, Ahmad-Reza

    2017-06-01

    Cholestatic itch can be severe and significantly impair the quality of life of patients. The serotonin system is implicated in cholestatic itch; however, the pruritogenic properties of serotonin have not been evaluated in cholestatic mice. Here, we investigated the serotonin-induced itch in cholestatic mice which was induced by bile duct ligation (BDL). Serotonin, sertraline or saline were administered intradermally to the rostral back area in BDL and sham operated (SHAM) mice, and the scratching behaviour was videotaped for 1 hour. Bile duct ligated mice had significantly increased scratching responses to saline injection on the seventh day after surgery. Additionally, serotonin or sertraline significantly induced scratching behaviour in BDL mice compared to saline at day 7 after surgery, while it did not induce itch at day 5. The scratching behaviour induced by serotonin or sertraline was significantly less in BDL mice compared to SHAM mice. Likewise, the locomotor activity of BDL or SHAM mice was not significantly different from unoperated (UNOP) mice on the fifth and seventh day, suggesting that the scratching behaviour was not affected by motor dysfunctions. Our data suggest that despite the potentiation of evoked itch, a resistance to serotonin-induced itch is developed in cholestatic mice. © 2017 John Wiley & Sons Australia, Ltd.

  18. The effect of cisterna chyli ablation combined with thoracic duct ligation on abdominal lymphatic drainage.

    Science.gov (United States)

    Sicard, Gretchen K; Waller, Ken R; McAnulty, Jonathan F

    2005-01-01

    To evaluate the effect of cisterna chyli ablation (CCA) and thoracic duct ligation (TDL) on abdominal lymphatic drainage in normal dogs. Experimental study. Nine female beagle dogs. TDL was performed in 3 dogs and was combined with CCA (CCA-TDL) and local omentalization in 6 dogs. Contrast lymphangiography was attempted in all dogs immediately before and after TDL. Dogs were reanesthetized at 31-37 days for lymphatic studies by new methylene blue (NMB) injection into a mesenteric lymph node and by contrast lymphangiography. In 6 CCA-TDL dogs, 2 had direct shunting of contrast from the lymphatic system into major abdominal veins, 3 had contrast material that dissipated into abdominal vessels within the mesenteric root, and 1 had shunting into the azygous vein. NMB was not observed within the omental pedicle after CCA-TDL. Chylous drainage was by the azygous vein in all 3 TDL dogs. CCA-TDL disrupted chylous drainage to the thoracic duct and resulted in direct intraabdominal lymphaticovenous anastomoses identified by shunting of lymphatic flow directly into the abdominal vasculature in 5 of 6 CCA-TDL dogs. Omentalization of the cisternal ablation site was not beneficial in augmenting extrathoracic lymphatic drainage and is not recommended with CCA-TDL. CCA-TDL represents a novel approach to surgical redirection of chylous drainage to the venous circulation outside of the thorax and may be useful in the treatment of spontaneous chylothorax in the dog.

  19. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  20. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  1. Injection moulding for macro and micro products

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    used for macro products but with the ages it is going deep into the micro areas having machine and process improvements. Extensive research work on injection moulding is going on all over the world. New ideas are flowing into the machines, materials and processes. The technology has made significant......The purpose of the literature survey is to investigate the injection moulding technology in the macro and micro areas from the basic to the state-of-the-art recent technology. Injection moulding is a versatile production process for the manufacturing of plastic parts and the process is extensively...

  2. Molecular characterization of apocrine salivary duct carcinoma.

    Science.gov (United States)

    Chiosea, Simion I; Williams, Lindsay; Griffith, Christopher C; Thompson, Lester D R; Weinreb, Ilan; Bauman, Julie E; Luvison, Alyssa; Roy, Somak; Seethala, Raja R; Nikiforova, Marina N

    2015-06-01

    Contemporary classification and treatment of salivary duct carcinoma (SDC) require its thorough molecular characterization. Thirty apocrine SDCs were analyzed by the Ion Ampliseq Cancer HotSpot panel v2 for mutations in 50 cancer-related genes. Mutational findings were corroborated by immunohistochemistry (eg, TP53, BRAF, β-catenin, estrogen, and androgen receptors) or Sanger sequencing/SNaPshot polymerase chain reaction. ERBB2 (HER2), PTEN, FGFR1, CDKN2A/P16, CMET, EGFR, MDM2, and PIK3CA copy number changes were studied by fluorescence in situ hybridization. TP53 mutations (15/27, 56%), PTEN loss (11/29, 38%, including 2 cases with PTEN mutation), PIK3CA hotspot mutations (10/30, 33%), HRAS hotspot mutations (10/29; 34%), and ERBB2 amplification (9/29, 31%, including 1 case with mutation) represented the 5 most common abnormalities. There was no correlation between genetic changes and clinicopathologic parameters. There was substantial overlap between genetic changes: 8 of 9 cases with ERBB2 amplification also harbored a PIK3CA, HRAS, and TP53 mutation and/or PTEN loss. Six of 10 cases with PIK3CA mutation also had an HRAS mutation. These findings provide a molecular rationale for dual targeting of mitogen-activated protein kinase and phosphoinositide 3-kinase pathways in SDC. FGFR1 amplification (3/29, 10%) represents a new potential target. On the basis of studies of breast carcinomas, the efficacy of anti-ERBB2 therapy will likely be decreased in SDC with ERBB2 amplification co-occurring with PIK3CA mutation or PTEN loss. Therefore, isolated ERBB2 testing is insufficient for theranostic stratification of apocrine SDC. On the basis of the prevalence and type of genetic changes, apocrine SDC appears to resemble one subtype of breast carcinoma-"luminal androgen receptor positive/molecular apocrine."

  3. A Pilot-Scale Evaluation of a New Technology to Control NO(x) Emissions from Boilers at KSC: Hydrogen Peroxide Injection into Boiler Flue Gases Followed by Wet Scrubbing of Acid Gases

    Science.gov (United States)

    Cooper, C. David

    1997-01-01

    Emissions of nitrogen oxides NO(x) are a significant problem in the United States. NO(x) are formed in any combustion process, therefore it is not surprising that NO(x) are emitted from the boilers at KSC. Research at UCF has shown (in the laboratory) that injecting H2O2 into hot simulated flue gases can oxidize the NO and NO2 to their acid gas forms, HNO2 and HNO3, respectively. These acid gases are much more water soluble than their counterparts, and theoretically can be removed easily by wet scrubbing. This technology was of interest to NASA, both for their boilers at KSC, and for their combustion sources elsewhere. However, it was necessary to field test the technology and to provide pilot-scale data to aid in design of full-scale facilities. Hence this project was initiated in May of 1996.

  4. Parametric study of electromagnetic waves propagating in absorbing curved S ducts

    Science.gov (United States)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.

  5. A realistic approach to modeling an in-duct desulfurization process based on an experimental pilot plant study

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, F.J.G.; Ollero, P. [University of Seville, Seville (Spain)

    2008-07-15

    This paper has been written to provide a realistic approach to modeling an in-duct desulfurization process and because of the disagreement between the results predicted by published kinetic models of the reaction between hydrated lime and SO{sub 2} at low temperature and the experimental results obtained in pilot plants where this process takes place. Results were obtained from an experimental program carried out in a 3-MWe pilot plant. Additionally, five kinetic models, from the literature, of the reaction of sulfation of Ca(OH){sub 2} at low temperatures were assessed by simulation and indicate that the desulfurization efficiencies predicted by them are clearly lower than those experimentally obtained in our own pilot plant as well as others. Next, a general model was fitted by minimizing the difference between the calculated and the experimental results from the pilot plant, using Matlab{sup TM}. The parameters were reduced as much as possible, to only two. Finally, after implementing this model in a simulation tool of the in-duct sorbent injection process, it was validated and it was shown to yield a realistic approach useful for both analyzing results and aiding in the design of an in-duct desulfurization process.

  6. Advantages and disadvantages of magnetic resonance cholangiography for patients with cholelithiasis with reference to those patients associated with dilatation of the common bile duct

    International Nuclear Information System (INIS)

    Higuchi, Takuya; Morimoto, Yoshikazu; Sumimura, Junichi; Miyazaki, Minoru

    2000-01-01

    Magnetic resonance cholangiography (MRC) was performed on patients with cholelithiasis with dilatation of the common bile duct (more than 10 mm in diameter) before surgery, and the advantages and disadvantages were investigated based on laparotomy findings. Subjects were 27 patients with cholelithiasis associated with common bile duct dilatation who were operated on at the department since June 1996. There were 13 men and 14 women. A mean age of them was 68.2±11.2 years, ranging from 43 to 90 years. As preoperative imagings, abdominal ultrasonography (US) and abdominal CT scan were performed in all cases; either of intravenous cholangiography (IVC), endoscopic retrograde cholangiography (ERCP), or percutaneous transhepatic cholangiography (PTC) was conducted in them; and MRC was performed in 22 cases except incompatible cases. Patients were imaged in the coronal planes by 0.5-T MR scanner employing a body surface coil at 10 second catch at a single breath-hold without injection of contrast medium. Twenty-one (21) out of 27 patients were proven to have common bile duct stones. The overall diagnostic accuracies in US, CT, IVC, and MRC were 40.7%, 62.9%, 68.4% and 86.3%, respectively. The diameters of common bile duct were ranged from 10 mm to 45 mm (mean 15.9±7.9 mm). MRC allows to assess microstones in the common bile duct, and moreover it is useful for postoperative or allergic patients. However, MRC can necessarily reveal peripapillary diverticulum, and it may overestimate the gallbladder in case of negative cholecystogram. MRC can noninvasively and rapidly reveal the presence of stones in the common bile duct, but further studies are required for a better evaluation of the potential disadvantages of this technique. (author)

  7. Abnormalities of intrahepatic bile ducts in extrahepatic biliary atresia.

    Science.gov (United States)

    Raweily, E A; Gibson, A A; Burt, A D

    1990-12-01

    The infantile cholangiopathies are a group of conditions associated with neonatal jaundice, which include extrahepatic biliary atresia, paucity of intra-hepatic bile ducts and disorders associated with persistence of fetal biliary structures, the so-called ductal plate malformations. Although previously regarded as distinct entities, it has recently been suggested that they may represent parts of a disease spectrum in which the principal process is one of bile duct destruction, the morphological manifestations in individual cases being influenced by the stage of intra-uterine development at which such injury occurs and by the site within the biliary system at which there is maximum damage. To further examine this concept, we have studied liver biopsy specimens from 37 neonates with extrahepatic biliary atresia, with particular reference to abnormalities of the intrahepatic bile ducts. Paucity of intrahepatic ducts, defined as a bile duct: portal tract ratio of less than 0.9, was identified in six cases (16.2%). In eight cases (21.6%) we found concentric tubular ductal structures similar to those observed in ductal plate malformations. In one case, both abnormalities could be demonstrated. Our findings support the concept that there is overlap between the various types of infantile cholangiopathy.

  8. High-Performance Ducts in Hot-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chitwood, Rick [National Renewable Energy Laboratory (NREL), Golden, CO (United States); German, Alea [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Weitzel, Elizabeth [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-07-30

    Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

  9. Primary Follicular Lymphoma of the Common Bile Duct Mimicking Cholangiocarcinoma

    Directory of Open Access Journals (Sweden)

    Khaled Youssef Elbanna

    2014-01-01

    Full Text Available Primary non-Hodgkin′s lymphoma of the common bile duct is extremely rare. We present a case with history of inflammatory bowel disease and clinical manifestations of obstructive jaundice. Abdominal magnetic resonance imaging with magnetic resonance cholangiopancreatography (MRCP was done and demonstrated tight stricture at the middle part of common bile duct, and radiological findings were supportive of extra-hepatic cholangiocarcinoma. Whipple′s procedure was performed and the case was histopathologically proven to be non-Hodgkin′s lymphoma of follicular subtype involving the common bile duct. Lymphoma of the hepatobiliary system is usually present as secondary manifestation of systemic malignant lymphoma. However, primary malignant lymphomas arising from the hepatobiliary tree are extremely rare. The radiological appearance of common bile duct lymphoma is very similar to cholangiocarcinoma, making preoperative diagnosis very difficult, as in our present case. We also compare the imaging findings of our case to those seen in reported cases of follicular lymphoma of the common bile duct.

  10. Radiation therapy in extrahepatic bile duct carcinoma

    International Nuclear Information System (INIS)

    Mahe, Marc; Romestaing, Pascale; Talon, Bernard; Ardiet, J.M.; Salerno, Nathalie; Sentenac, Irenee; Gerard, J.P.

    1991-01-01

    Fifty-one patients with carcinoma of the extrahepatic bile ducts (EHBD) received radiation therapy between Jan 1980-Dec 1988. The location of the tumors was: proximal third, 20 patients; middle third, 23; distal third, 3; diffuse, 5 patients. Thirty-six patients underwent surgery with complete gross resection in 14 (10/14 with positive margins), incomplete gross resection in 12 and only biopsy in 10. Fifteen patients had only biliary drainage without laparotomy after cytologic diagnosis of malignancy in 11/15. Radiation therapy was done with curative intent after complete or incomplete resection (n=26) and it was palliative in patients who had no resection or only biliary drainage (n=25). Twenty-five patients received external radiation-therapy (ERT) alone to the tumor and lymph nodes (mean dose 45 Gy/2Gy per fraction for cure, 35 Gy/10 fractions for palliation), 8 patients had only iridium-192 ( 192 Ir) implant (50-60 Gy at a 1 cm radius for cure, 30 Gy for palliation), 17 patients had both ERT + 192 Ir(ERT 42.5 Gy + 192 Ir 10-15 Gy for cure; ERT 20 Gy/5 fractions + 192 Ir 20-30 Gy for palliation) and one intra-operative irradiation + ERT. The overall survival rate for the entire group was 55, 28.5 and 15 percent at 12, 24, 36 months and median survival 12 months. Median survival was 22 months in patients treated with curative intent and only 10 months after palliative treatment (p0.03). Among patients who had curative treatment, median survival was 27.5 months after complete gross resection and 13 months after incomplete gross resection (p0.045). After complete gross resection 5/14 patients were alive without evolutive disease at 11, 19, 20, 23 and 41 months, 2 were alive with metastases at 25 and 27 months and 7/14 died of cancer from 7 to 59 months. The rate of complications was low: 3 cholangitis responsive to antibiotics, 1 hemobilia and 2 gastric ulcers. These results are encouraging especially for patients with complete gross resection but they must be

  11. Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.

    Science.gov (United States)

    Celebi, Ahmet; Demir, Ibrahim Halil; Saritaş, Türkay; Dedeoğlu, Reyhan; Yucel, Ilker Kemal; Demir, Fadli; Erdem, Abdullah

    2013-11-15

    We sought to investigate the safety, efficacy, and follow-up results of percutaneous patent ductus arteriosus (PDA) closure using the novel Cardi-O-Fix duct occluder (CDO), a device similar to but less expensive than the Amplatzer duct occluder (ADO). We also aimed to compare these two devices in terms of results. Between March 2005 and May 2012, 167 patients diagnosed with moderate-to-large PDA underwent transcatheter closure. ADO was used in 56 (33.5%) patients with a mean age of 8.1 ± 11.9 years (3.6 months-56 years), whereas CDO was used in 111 (66.5%) patients with a mean age of 12.6 ± 14.6 years (4.8 months-63 years). The narrowest PDA diameter, the used device diameter, procedure time, fluoroscopy time, and residual shunt rates were similar between the two groups. Procedural success rate was 100% in both groups. Although the residual shunt rate was higher in the CDO group immediately after the procedure, the difference was not statistically significant (12.6 vs. 8.9%; P = 0.3). There was no statistically significant difference between groups at discharge and during follow-up. No deaths occurred in any of the groups, and there were no differences in complication rates during the short- and mid-term follow-up periods (CDO 7/111 vs. ADO 5/56; P = 0.5 π). The CDO can be used for PDA closure because of its safety, effectiveness, and simplicity in use. It is available in bigger sizes and can be used in patients with large defects. According to our short- and mid-term findings, the results it yields are similar to those of the ADO; thus, it may be the preferred choice owing to its low cost and large size variability. Copyright © 2013 Wiley Periodicals, Inc.

  12. Steam Injection For Soil And Aquifer Remediation

    Science.gov (United States)

    The purpose of this Issue Paper is to provide to those involved in assessing remediation technologies for specific sites basic technical information on the use of steam injection for the remediation of soils and aquifers that are contaminated by...

  13. Prolapse of inverted ileal loops through a patent vitellointestinal duct

    Science.gov (United States)

    Pathak, Ashish; Agarwal, Nitin; Singh, Poonam; Dhaneria, Mamta

    2015-01-01

    We report a case of a prolapsed patent vitellointestinal duct (PVID) in a 2-month-old girl child who presented with sudden increase in size of a polypoidal lesion into a large, ‘Y’-shaped reddish, prolapsing lesion, discharging gaseous and faecal matter at her umbilicus. The lesion was diagnosed as a prolapse of inverted ileal loops through the PVID. The child had no associated congenital anomalies. A transumbilical exploration was performed, followed by wedge resection and anastomosis. The child tolerated the procedure well and the postoperative course was uneventful. If the omphalomesenteric duct fails to obliterate a range of congenital defects related to the umbilicus, it can become clinically apparent. Meckel's diverticulum is the commonest of these defects but is most often asymptomatic. PVID is the most common symptomatic anomaly of the patent omphalomesenteric duct and requires prompt surgical correction to avoid complications. PMID:26494719

  14. Squamous Cell Carcinoma of the Hilar Bile Duct

    Directory of Open Access Journals (Sweden)

    Ippei Yamana

    2011-08-01

    Full Text Available We herein report a rare case of squamous cell carcinoma of the hilar bile duct. A 66-year-old Japanese male patient was admitted to our hospital because of appetite loss and jaundice. Abdominal computed tomography revealed an enhanced mass measuring 10 × 30 mm in the hilar bile duct region. After undergoing biliary drainage, the patient underwent extended right hepatic lobectomy with regional lymph nodes dissection. The tumor had invaded the right portal vein. Therefore, we also performed resection and reconstruction of the portal vein. Histopathologically, the carcinoma cells exhibited a solid structure with differentiation to squamous cell carcinoma with keratinization and intercellular bridges. Immunohistochemical staining of the tumor cells revealed positive cytokeratin staining and negative CAM 5.2 staining. Based on these findings, a definitive diagnosis of well-differentiated squamous cell carcinoma of the hilar bile duct was made.

  15. Intracellular pH in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I; Hug, M; Greger, R

    1997-01-01

    In order to study the mechanism of H+ and HCO3- transport in a HCO3- secreting epithelium, pancreatic ducts, we have measured the intracellular pH (pHi) in this tissue using the pH sensitive probe BCECF. We found that exposures of ducts to solutions containing acetate/acetic acid or NH4+/NH3...... buffers (20 mmol/l) led to pHi changes in accordance with entry of lipid-soluble forms of the buffers, followed by back-regulation of pHi by duct cells. In another type of experiment, changes in extracellular pH of solutions containing HEPES or HCO3-/CO2 buffers led to significant changes in pHi that did....... Under some conditions, these exchangers can be invoked to regulate cell pH....

  16. Diagnosis of functional nasolacrimal duct obstruction using dacryoscintigraphy

    International Nuclear Information System (INIS)

    Lim, Hyun Wook; Sohn, Hyung Sun; Kim, Euy Neyng; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo

    2000-01-01

    To evaluate the value of dacryoscintigraphy in the assessment of patients with a clinical diagnosis of functional nasolacrimal duct obstruction. Dacryoscintigraphy was performed in symptomatic 35 lacrimal drainage systems in 18 patients (age range: 37 ∼76,8 males, 10 females) that were patent on syringing. Abnormalities were detected with dacryoscintigraphy in 75.8% of systems. The positive scintigrams were subdivided into those demonstrating prelacrimal sac delay (31.8%), delay at the lacrimal sac/junction (40.9%), or delay within the duct (27%). Dacryoscintigraphy is noninvasive useful technique in the assessment of the functional nasolacrimal duct obstruction and very sensitive at detecting abnormalities in patients with lid laxity caused by senile change and facial nerve palsy

  17. Bile Duct Obstruction Secondary to Chronic Pancreatitis in Seven Dogs

    Science.gov (United States)

    Cribb, Alastair E.; Burgener, David C.; Reimann, Keith A.

    1988-01-01

    Seven icteric dogs were determined to have bile duct obstruction secondary to chronic pancreatitis. All dogs had histories of intermittent vomiting and diarrhea. Alkaline phosphatase and alanine aminotransferase activities and total bilirubin concentrations were markedly elevated. Diagnosis was based on exploratory laparotomy and histological examination. Each dog had a 3 to 10 cm mass in the body of the pancreas and obstruction of the common bile duct. Three dogs treated with pancreatectomy, gastrojejunostomy, and cholecystojejunostomy died within five weeks. Three dogs treated with conservative surgical procedures were alive at 8, 16, and 26 months postoperatively. One dog was euthanized because of suspected neoplasia. Hepatic enzyme activity and bilirubin levels decreased markedly in the surviving dogs. Histological examination of the pancreatic masses indicated chronic pancreatitis. Hepatic biopsies revealed evidence of cholestasis. Chronic pancreatitis should be included in the differential diagnoses of icterus, bile duct obstruction, and masses in the pancreas. PMID:17423102

  18. [Qilin Pills for obstructive azoospermia after ejaculatory duct reconstruction].

    Science.gov (United States)

    Zhang, Lei; Gao, Ping; Ren, Fei-Qiang; Chang, De-Gui; Yu, Xu-Jun; Zhang, Pei-Hai

    2016-09-01

    To observe the clinical effect of Qilin Pills in the treatment of severe oligozoospermia after microsurgical ejaculatory duct reconstruction for obstructive azoospermia. We retrospectively analyzed 75 cases of obstructive azoospermia treated by ejaculatory duct reconstruction followed by administration of Qilin Pills. The patients were divided into a Qilin group (n=42) and a control group (n=33) postoperatively, treated with Qilin Pills and placebo, respectively. After 3 months of medication, we compared the sperm quality between the two groups of patients. After 3 months' treatment, all the patients experienced remarkable improvement in sperm quality (P0.05). The total effectiveness rate was higher in the Qilin group than in the controls (88.1% vs 72.7%), but with no significant difference between the two groups (P>0.05). Qilin Pills are fairly effective in improving the quantity of sperm in obstructive azoospermia patients after ejaculatory duct reconstruction.

  19. Thermal behavior of the duct applied functionally graded material

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Sun; Yoon, Dong Young; Im, Jong Bin [Hankuk Aviation Univ., Goyang (Korea, Republic of)

    2004-07-01

    In Unmanned Aerial Vehicles (UAV), the high temperature results from friction among the air, combustion of fuel in engine and combustion gas of a nozzle. The high temperature may cause serious damages in UAV structure. The Functionally Graded Material(FGM) is chosen as a material of the engine duct structure. Thermal stress analysis of FGM is performed in this paper. FGM is composed of two constituent materials that are mixed up according to the specific volume fraction distribution in order to withstand high temperature. Therefore, hoop stress, axial stress and shear stress of duct with 2 layers, 4 layers and 8 layers FGM are compared and analyzed respectively. In addition, the creep behavior of FGM used in duct structure of an engine is analyzed for better understanding of FGM characteristics.

  20. Design of a Mobile Robot for Air Ducts Exploration

    Directory of Open Access Journals (Sweden)

    Moses A. Koledoye

    2017-10-01

    Full Text Available This work presents the solutions adopted for the design and the implementation of an autonomous wheeled robot developed for the exploration and mapping of air ventilation ducts. The hardware is based on commercial off-the-shelf devices, including sensors, motors, processing devices and interfaces. The mechanical chassis was designed from scratch to meet a trade-off between small size and available volume to host the components. The software stack is based on the Robot Operating System (ROS. Special attention was dedicated to the design of the mobility strategy, which must take into account some constraints and issues that are specific to the considered application, such as the relatively small size of ducts, the need to detect and avoid possible holes on the floor of the duct and other unusual obstacles and the unavailability of external reference frameworks for localization. The main contribution of this paper lies in the design, implementation and experimentation of the overall system.

  1. Thyroid cancer in lingual thyroid and thyroglossal duct cyst.

    Science.gov (United States)

    Sturniolo, Giacomo; Vermiglio, Francesco; Moleti, Mariacarla

    2017-01-01

    Ectopy is the most common embryogenetic defect of the thyroid gland, representing between 48 and 61% of all thyroid dysgeneses. Persistence of thyroid tissue in the context of a thyroglossal duct remnant and lingual thyroid tissue are the most common defects. Although most cases of ectopic thyroid are asymptomatic, any disease affecting the thyroid may potentially involve the ectopic tissue, including malignancies. The prevalence of differentiated thyroid carcinoma in lingual thyroid and thyroglossal duct cyst is around 1% of patients affected with the above thyroid ectopies. We here review the current literature concerning primary thyroid carcinomas originating from thyroid tissue on thyroglossal duct cysts and lingual thyroid. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. High-frequency data observations from space shuttle main engine low pressure fuel turbopump discharge duct flex joint tripod failure investigation

    Science.gov (United States)

    Zoladz, T. F.; Farr, R. A.

    1991-01-01

    Observations made by Marshall Space Flight Center (MSFC) engineers during their participation in the Space Shuttle Main Engine (SSME) low pressure fuel turbopump discharge duct flex joint tripod failure investigation are summarized. New signal processing techniques used by the Component Assessment Branch and the Induced Environments Branch during the failure investigation are described in detail. Moreover, nonlinear correlations between frequently encountered anomalous frequencies found in SSME dynamic data are discussed. A recommendation is made to continue low pressure fuel (LPF) duct testing through laboratory flow simulations and MSFC-managed technology test bed SSME testing.

  3. Adenomas of the common bile duct in familial adenomatous polyposis

    Science.gov (United States)

    Yan, Mao-Lin; Pan, Jun-Yong; Bai, Yan-Nan; Lai, Zhi-De; Chen, Zhong; Wang, Yao-Dong

    2015-01-01

    Familial adenomatous polyposis (FAP) or Gardner’s syndrome is often accompanied by adenomas of the stomach and duodenum. We experienced a case of adenomas of the common bile duct in a 40-year-old woman with FAP presenting with acute cholangitis. Only 8 cases of adenomas or adenocarcinoma of the common bile duct have been reported in the literature in patients with FAP or Gardner’s syndrome. Those patients presented with acute cholangitis or pancreatitis. Local excision or Whipple procedure may be the reasonable surgical option. PMID:25780319

  4. Advanced Strategy Guideline: Air Distribution Basics and Duct Design

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

  5. Parametric investigation of fracture of EBR-II ducts

    International Nuclear Information System (INIS)

    Chopra, P.S.; Moustakakis, B.

    1977-01-01

    Results of preliminary static and dynamic finite element fracture mechanics analyses that were conducted to analytically simulate the dynamic fracture behavior of EBR-II ducts are presented. The loads considered are those that may arise because of rapid release of fission gases from a failed fuel element inside a duct, obtained from some previous tests and a recent analytical model. In spite of the motivation for the present work, the analytical procedures described may have a wider general application in the fail-safe design of structures

  6. Clinical implications of bile duct injury after transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Wang Maoqiang; Tang Wenjie; Lin Hanying; Ye Huiyi; Dai Guanghai; Wang Zhiqiang

    2005-01-01

    Objective: To evaluate the incidence, risk factors , and clinical course of bile duct injury after transcatheter arterial chemoembolization (TACE) for treatment of hepatic malignancy. Methods: A total of 1240 consecutive patients with hepatic malignancies underwent 2680 TACE procedures. None of these patients were found to have any radiographic evidence of biliary abnormalities pre-TACE. Eighteen patients developed bile duct injuries at 3 weeks to 3 months after TACE. A retrospective review of medical records and imaging studies were carried out to evaluate the occurrence of TACE-induced bile duct injury, the clinical outcome, and the statistical significance of potential predisposing factors. Results: The TACE-induced bile duct injuries occurred in 13 of 148 patients with liver metastatic tumors (8.8%), 5 of 1092 patients with HCC (0.5%). Biliary injuries, including focal (n=4) and multiple intrahepatic bile duct dilatation (n=8), and cystic lesion or biloma (n=6), were identified on the follow-up imaging studies after TACE. Three patients with multiple bile duct injuries had mild jaundice at the presentation, two of them responded well to the conservative treatment, one died of irreversible deterioration of liver function at 2 weeks after the onset of jaundice. Four patients with a large biloma had associated serious bacterial infections; 3 of which were treated with percutaneous catheter drainage and antibiotics, 2 of them died of purulent peritonitis due to rupture of the cystic lesions and 1 cured with antibiotic. The remaining 11 patients were asymptomatic. The mortality related to the biliary injury occurred in 3 patients (16.7%). The incidences of bile duct injury were higher in patients with metastatic tumors in non-cirrhotic livers than in patients with hepatocellular carcinoma associated with cirrhosis (P<0.01), higher in patient with hypovascular lesions (P<0.01), and higher in patients using an emulsion of lipiodol-platinum for selective embolization

  7. Simultaneous Papillary Carcinoma in Thyroglossal Duct Cyst and Thyroid

    Directory of Open Access Journals (Sweden)

    Gustavo Cancela e Penna

    2017-01-01

    Full Text Available Thyroglossal duct cyst (TDC is a cystic expansion of a remnant of the thyroglossal duct tract. Carcinomas in the TDC are extremely rare and are usually an incidental finding after the Sistrunk procedure. In this report, an unusual case of a 36-year-old woman with concurrent papillary thyroid carcinoma arising in the TDC and on the thyroid gland is presented, followed by a discussion of the controversies surrounding the possible origins of a papillary carcinoma in the TDC, as well as the current management options.

  8. Analysis of materials in ducts by Compton scattering

    International Nuclear Information System (INIS)

    Gouveia, M.A.G.; Lopes, R.T.; Jesus, E.F.O. de; Camerini, C.S.

    2000-01-01

    This work presents the use of the Compton Scattering Technique as essay, for materials characterization in petroleum ducts. The essay have been accomplished in laboratory ambit, so that the presented results should be analyzed so that the system can come to be used in the field. The inspection was performed using Compton Scattering techniques, with two detectors aligned, in an angle of 90 degrees with a source of Cs-137 with energy of 662 keV. The results demonstrated the good capacity of the system to detect materials deposited in petroleum ducts during petroleum transportation. (author)

  9. Mechanism of floating body effect mitigation via cutting off source injection in a fully-depleted silicon-on-insulator technology

    International Nuclear Information System (INIS)

    Huang Pengcheng; Chen Shuming; Chen Jianjun

    2016-01-01

    In this paper, the effect of floating body effect (FBE) on a single event transient generation mechanism in fully depleted (FD) silicon-on-insulator (SOI) technology is investigated using three-dimensional technology computer-aided design (3D-TCAD) numerical simulation. The results indicate that the main SET generation mechanism is not carrier drift/diffusion but floating body effect (FBE) whether for positive or negative channel metal oxide semiconductor (PMOS or NMOS). Two stacking layout designs mitigating FBE are investigated as well, and the results indicate that the in-line stacking (IS) layout can mitigate FBE completely and is area penalty saving compared with the conventional stacking layout. (paper)

  10. Positioning of supporting-cable ducts in a prestressed concrete bridge

    International Nuclear Information System (INIS)

    Roetzer, H.

    1981-01-01

    Before inserting the supporting cables positioning of cable ducts in prestressed concrete bridges can be performed with the aid of radiation sources hauled through the ducts and localized by means of radiation monitors

  11. Endoscopic versus surgical drainage of the pancreatic duct in chronic pancreatitis

    NARCIS (Netherlands)

    Cahen, Djuna L.; Gouma, Dirk J.; Nio, Yung; Rauws, Erik A. J.; Boermeester, Marja A.; Busch, Olivier R.; Stoker, Jaap; Lameris, Johan S.; Dijkgraaf, Marcel G. W.; Huibregtse, Kees; Bruno, Marco J.

    2007-01-01

    BACKGROUND: For patients with chronic pancreatitis and a dilated pancreatic duct, ductal decompression is recommended. We conducted a randomized trial to compare endoscopic and surgical drainage of the pancreatic duct. METHODS: All symptomatic patients with chronic pancreatitis and a distal

  12. ASSESSMENT OF FUNGAL (PENICILLIUM CHRYSOGENUM) GROWTH ON THREE HVAC DUCT MATERIALS

    Science.gov (United States)

    The article discusses laboratory experiments to evaluate the susceptibility of three ventilation duct materials (fibrous glass ductboard, galvanized steel, and insulated flexible duct) to fungal (P. chrysogenum) growth. [NOTE: Many building investigators have documented fungal bi...

  13. Endoscopic Management of Perforation of Right Hepatic Duct Following Non-Surgical Abdominal Trauma

    OpenAIRE

    Sharma, B. C.; Maini, A.; Saraswat, V. A.

    1997-01-01

    Isolated bile duct injuries after blunt abdominal trauma are rare. Surgery is the usual mode of treatment. We report a patient with a right hepatic duct injury following blunt abdominal trauma who was managed successfully by endoscopic papillotomy.

  14. Congenital double bile duct presenting as recurrent cholangitis in a child

    Directory of Open Access Journals (Sweden)

    K.D. Chakravarty

    2015-12-01

    Full Text Available Double common bile duct (DCBD is a rare congenital anomaly. Most of these bile duct anomalies are associated with bile duct stones, anomalous pancreaticobiliary junction (APBJ, pancreatitis and bile duct or gastric cancers. Early detection and treatment is important to avoid long term complications. Surgical resection of the anomalous bile duct and reconstruction of the biliary enteric anastomosis is the treatment of choice. We report a rare case of DCBD anomaly in a girl, who presented with recurrent cholangitis. She had type Va DCBD anomaly. She underwent successful resection of the bile duct and reconstruction of the biliary enteric anastomosis. Preoperative imaging and diagnosis of the congenital biliary anomaly is very important to avoid intraoperative bile duct injury. Review of the literature shows very few cases of type Va DCBD, presenting with either bile duct stones or APBJ.

  15. Pancreatic-duct-lavage cytology in candidates for surgical resection of branch-duct intraductal papillary mucinous neoplasm of the pancreas: should the International Consensus Guidelines be revised?

    Science.gov (United States)

    Sai, Jin Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio; Maehara, Tadayuki

    2009-03-01

    The International Consensus Guidelines are helpful for the management of branch-duct intraductal papillary mucinous neoplasms (IPMNs), because they allow us to exclude malignancy. However, it is not possible to predict malignancy with certainty, and further preoperative differentiation between benign and malignant IPMNs is required to avoid the false-positive results. To examine the usefulness of pancreatic-duct-lavage cytology by using an originally designed double-lumen catheter for discriminating benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines. Pancreatic-duct-lavage cytology was investigated in 24 patients with branch-duct IPMNs who underwent surgical resection based on the International Consensus Guidelines, namely, they either had intramural nodules or the ectatic branch duct was >30 mm in diameter. Single-center retrospective study. Academic medical center. The sensitivity and specificity of pancreatic-duct-lavage cytology for discriminating benign from malignant IPMNs. More than 30 mL of pancreatic-duct-lavage fluid was obtained from each patient, and there were no patients with noninformative results. The sensitivity, specificity, positive predictive value, and negative predictive value of the cytologic diagnosis were 78%, 93%, 88%, and 88%, respectively. Single-center and small number of patients. Pancreatic-duct-lavage cytology can improve differentiation between benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines.

  16. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D.; McIlvaine , J.; Fonorow, K.; Martin, E.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition to enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.

  17. U. S. programs on reference and advanced cladding/duct materials

    International Nuclear Information System (INIS)

    Bennett, J.W.; Holmes, J.J.; Laidler, J.J.

    1977-05-01

    Two coordinated national programs are presently in place in the United States for development of reference and advanced cladding and duct alloys for near-term and long-term LMFBR applications. A number of government, industrial and university laboratories are active participants in these two ERDA-sponsored programs. The programs are administered by ERDA through a task group organization, with each task group representing a particular technical activity and the membership of the task group drawn from among the laboratories with active involvement in that activity. Technical coordination of the two programs is provided by the Hanford Engineering Development Laboratory. The National Reference Cladding and Duct Program is charged with the responsibility for development of the required technology to permit full utilization of the reference material, 20 percent cold-worked Type 316 stainless steel, in early LMFBR core applications. The current schedule calls for full evaluation of FFTF-related design base data prior to full-power operation of FFTF in early 1980, followed by a confirmation in early 1983 of reference material performance capabilities for initial-core CRBRP applications. Comprehensive evaluation of reference material performance to commercial plant goal fluence levels will be complete by 1985. The National Advanced Alloy Development Program was instituted in 1974 with the objective to develop, by 1986, advanced cladding and duct materials compatible with advanced fuel systems having peak burnup capabilities up to 150 MWD/kg and doubling times of 15 years or less. Screening of a large number of potential alloys was completed in mid-1975, and there are presently 16 candidate alloys under active investigation

  18. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  19. Practical use of CFD for air conditioning duct and defroster designing; Kucho duct defroster no CFD sekkei katsuyo

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, K [Daihatsu Motor Co. Ltd., Osaka (Japan)

    1997-10-01

    The automobile industry have made effort to shorten the development period. Recently CFD (Computational Fluid Dynamics) on initial design stage becomes use for improvement of development efficiency. Although the practical guidepost (computed examples) for air conditioning duct and defroster are a little reported. This report presents how to optimize and standardize the calculational methods, calculational grid, boundary conditions for air conditioning duct and defroster nozzle in the practical use. Also we tried the discontinuous interface grid and the solution adaptive method. 2 refs., 17 figs.

  20. A simple method to calculate the neutron flow through full ducts

    International Nuclear Information System (INIS)

    Faik Ouahab, Z.; Jehouani, A.; Ghassoun, J.; Senhou, N.; Groetz, J.E.

    2010-01-01

    Summary of a study of assessment of the probability for neutrons to be guided in a full duct with a square cross section and doubly bent. Two software have been developed, based on the Monte Carlo simulation, to compute the neutron transmission probability at the end of the duct. Results are in good agreement with that obtained with the MCNP-5 code. The neutron flow and probability at the duct end have been determined for different materials and different duct dimensions

  1. Chitin in the Silk Gland Ducts of the Spider Nephila edulis and the Silkworm Bombyx mori

    Science.gov (United States)

    Davies, Gwilym J. G.; Knight, David P.; Vollrath, Fritz

    2013-01-01

    Here we report the detection and localisation of chitin in the cuticle of the spinning ducts of both the spider Nephila edulis and the silkworm Bombyx mori. Our observations demonstrate that the duct walls of both animals contain chitin notwithstanding totally independent evolutionary pathways of the systems. We conclude that chitin may well be an essential component for the construction of spinning ducts; we further conclude that in both species chitin may indicate the evolutionary origin of the spinning ducts. PMID:24015298

  2. Ducting Conditions for Electromagnetic Wave Propagation in Tropical Disturbances from GPS Dropsonde Data

    Science.gov (United States)

    2013-12-01

    depression, tropical storm , hurricane, extratropical cyclone, subtropical depression, subtropical storm , a low of no category, tropical wave, disturbance or...surface-based ducts, and elevated ducts. We further separate the duct occurrence based on the location relative to their respective storms . Based...on the number of soundings in different types of tropical disturbances, we chose to further analyze duct conditions in hurricanes and tropical storms

  3. Resin duct characteristics in the wood of fire-scarred North American conifers

    Science.gov (United States)

    Estelle Arbellay; Markus Stoffel; Elaine K. Sutherland; Kevin T. Smith; Donald A. Falk

    2013-01-01

    Traumatic resin ducts form in xylem and phloem tissue of conifers in response to abiotic wounding, fungal invasion, and insect attack. Little is known about resin duct characteristics in the wood of fire-scarred trees. The aim of this study is to quantify changes in traits of both axial and radial resin ducts, along with those of associated epithelial cells and...

  4. Effects of partial portal vein arterialization on the hilar bile duct in a rat model.

    Science.gov (United States)

    Guo, Shao-Hua; Li, Chong-Hui; Chen, Yong-Liang; Song, Jian-Ning; Zhang, Ai-Qun; Zhou, Cheng

    2011-10-01

    Liver revascularization is frequently required during the enlarged radical operation for hilar cholangiocarcinoma involving the hepatic artery. Researchers have carried out a number of experiments applying partial portal vein arterialization (PVA) in clinical practice. In this study we aimed to establish a theoretical basis for clinical application of partial PVA and to investigate the effects of partial PVA on rat hilar bile duct and hepatic functions. Thirty rats were randomly and equally assigned into 3 groups: control (group A), hepatic artery ligation+bile duct recanalization (group B), and partial PVA+bile duct recanalization (group C). Proliferation and apoptosis of rat hilar bile duct epithelial cells, arteriolar counts of the peribiliary plexus (PBP) of the bile duct wall, changes in serum biochemistry, and pathologic changes in the bile duct were assessed 1 month after operation. The proliferation of hilar bile duct epithelial cells in group B was greater than in groups A and C (Philar bile duct epithelial cells were detected in any of the groups. The PBP arteriolar counts of the hilar bile duct wall were similar in groups A and C (P>0.05), but the count was lower in group B than in group A (Philar bile duct walls were observed only in group B. Partial PVA can restore the arterial blood supply of the hilar bile duct and significantly extenuate the injury to hilar bile duct epithelial cells resulting from hepatic artery ligation.

  5. Erlotinib in Treating Patients With Unresectable Liver, Bile Duct, or Gallbladder Cancer

    Science.gov (United States)

    2013-06-03

    Adult Primary Cholangiocellular Carcinoma; Adult Primary Hepatocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer

  6. Spontaneous bile duct perforation in an infant, managed with simple ...

    African Journals Online (AJOL)

    Spontaneous bile duct perforation is a very rare but important cause of surgical jaundice in pediatric patients and one of the most common causes of surgical jaundice during infancy after biliary atresia. Preoperative diagnosis may not be possible in most of the cases. The exact cause of the perforation remains unclear.

  7. Design requirement on KALIMER blanket fuel assembly duct

    International Nuclear Information System (INIS)

    Hwang, Woan; Kang, H. Y.; Nam, C.; Kim, J. O.

    1998-03-01

    This document describes design requirements which are needed for designing the blanket fuel assembly duct of the KALIMER as design guidance. The blanket fuel assembly duct of the KALIMER consists of fuel rods, mounting rail, nosepiece, duct with pad, handling socket with pad. Blanket fuel rod consists of top end plug, bottom end plug with solid ferritic-martensitic steel rod and key way blanket fuel slug, cladding, and wire wrap. In the assembly, the rods are in a triangular pitch array, and the rod bundle is attached to the nosepiece with mounting rails. The bottom end of the assembly duct is formed by a long nosepiece which provides the lower restraint function and the paths for coolant inlet. This report contains functional requirements, performance and operational requirements, interfacing systems requirements, core restraint and interface requirements, design limits and strength requirements, system configuration and essential feature requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. (author). 20 refs., 4 figs

  8. Two phase flow combustion modelling of a ducted rocket

    NARCIS (Netherlands)

    Stowe, R.A.; Dubois, C.; Harris, P.G.; Mayer, A.E.H.J.; Champlain, A. de; Ringuette, S.

    2001-01-01

    Under a co-operative program, the Defence Research Establishment Valcartier and Université Laval in Canada and the TNO Prins Maurits Laboratory in the Netherlands have studied the use of a ducted rocket for missile propulsion. Hot-flow direct-connect combustion experiments using both simulated and

  9. Reconstruction of major bile duct injuries after laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Holte, Kathrine; Bardram, Linda; Wettergren, André

    2010-01-01

    Bile duct injury (BDI) after cholecystectomy remains a serious complication with major implications for patient outcome. For most major BDIs, the recommended method of repair is a hepaticojejunostomy (HJ). We conducted a retrospective review aiming to examine the perioperative and the long...

  10. Optimizing the Treatment of Acute Duct-Destructive Pancreatitis

    Science.gov (United States)

    Zhakiev, Bazylbek S.; Karsakbayev, Uteugali G.; Kelimberdiev, Mersaid S.; ?uhamedgalieva, Bodagoz M.; K?nonenko, Aleksander F.

    2016-01-01

    The search for new methods for treating duct-destructive pancreatitis is a relevant problem. Endogenous intoxication and oxidative stress that accompany acute pancreatitis often progress even after surgery, which forces one to search for additional possibilities of preventing these severe consequences. This research studied the effect of small…

  11. Laparoscopic managment of common bile duct stones: our initial experience.

    Science.gov (United States)

    Aroori, S; Bell, J C

    2002-05-01

    The management of choledocholithiasis has changed radically since the introduction of laparoscopic cholecystectomy. However, perceived technical difficulties have deterred many surgeons from treating common bile duct stones laparoscopically at the time of cholecystectomy. This has lead to reliance on endoscopic retrograde cholangiopancreatography followed by endoscopic sphincterotomy to deal with common bile duct stones. We retrospectively reviewed the charts of patients who had laparoscopic common bile duct exploration at Downe Hospital between December 1999 and August 2001. Among 149 laparoscopic cholecystectomies done by our group in this period, 10 patients (6.7%) underwent laparoscopic CBD exploration, three by the transcystic technique and seven by choledochotomy. Three patients (2%) had unsuspected stones found on routine per- operative cholangiogram. The mean operative time was 2.34hrs (range 1.50-3.30hrs). The mean hospital post- operative stay was 3 days (range 1-6 days). Post-operative morbidity was zero. Stone clearance was achieved in all cases. We conclude, laparoscopic exploration of the common bile duct is relatively safe and straightforward method. The key skill required is the ability to perform laparoscopic suturing with confidence.

  12. Cladding and Duct Materials for Advanced Nuclear Recycle Reactors

    International Nuclear Information System (INIS)

    Allen, Todd R.; Busby, J. T.; Klueh, R. L.; Maloy, Stuart A.; Toloczko, Mychailo B.

    2008-01-01

    This is a review article that provides an overview of the reactor core structural materials and clad and duct needs for the GNEP advanced burner reactor design. A short history of previous research on structural materials for irradiation environments is provided. There is also a section describing some advanced materials that may be candidate materials for various reactor core structures

  13. Flow in curved ducts of varying cross-section

    Science.gov (United States)

    Sotiropoulos, F.; Patel, V. C.

    1992-07-01

    Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.

  14. Discontinuous finite element treatment of duct problems in transport calculations

    International Nuclear Information System (INIS)

    Mirza, A. M.; Qamar, S.

    1998-01-01

    A discontinuous finite element approach is presented to solve the even-parity Boltzmann transport equation for duct problems. Presence of ducts in a system results in the streaming of particles and hence requires the employment of higher order angular approximations to model the angular flux. Conventional schemes based on the use of continuous trial functions require the same order of angular approximations to be used everywhere in the system, resulting in wastage of computational resources. Numerical investigations for the test problems presented in this paper indicate that the discontinuous finite elements eliminate the above problems and leads to computationally efficient and economical methods. They are also found to be more suitable for treating the sharp changes in the angular flux at duct-observer interfaces. The new approach provides a single-pass alternate to extrapolation and interactive schemes which need multiple passes of the solution strategy to acquire convergence. The method has been tested with the help of two case studies, namely straight and dog-leg duct problems. All results have been verified against those obtained from Monte Carlo simulations and K/sup +/ continuous finite element method. (author)

  15. Thyroglossal Duct Papillary Thyroid Carcinoma and Synchronous Lingual Thyroid Atypia

    Directory of Open Access Journals (Sweden)

    Timothy Yoo

    2016-01-01

    Full Text Available Thyroglossal duct and lingual thyroid ectopic lesions are exceedingly rare synchronous findings. Papillary thyroid carcinoma of these ectopic thyroid sites is well understood but still a rare finding. This case points to some management nuances in regard to ectopic thyroid screening with imaging and also shows the effectiveness of minimally invasive transoral robotic surgery for lingual thyroid.

  16. Percutaneous management of bile duct injury after laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Islim, F.; Ors, S.; Salik, A.; Guven, K.; Yanar, F.; Alis, H.

    2012-01-01

    Full text: Introduction: The risk of bile duct injury after laparoscopic cholecystectomy is higher than open cholecystectomy. Objective: To discuss the importance of minimally invasive treatment options in the management of bile duct injuries after laparoscopic cholecystectomy and to present our approach in the management. Materials and methods: Management of 25 patients with symptomatic bile duct injury after laparoscopic cholecystectomy was retrospectively evaluated. Percutaneous collection drainage, endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTC) and percutaneous biliary drainage were performed for the management of the patients. Results: Mean age of the patients (15 women, 10 men) was 55. Either ultrasonography or computed tomography guided percutaneous drainage was performed in 13 patients. 9 of them completely recovered only with percutaneous drainage. In 4 of them ERCP was performed because of high drainage volume. In 9 of the patients with jaundice and high bilirubin levels ERCP was performed as the first option. And 3 patients were reoperated because of acute abdomen signs. ERCP, MRCP and PTC revealed type A in 7, type E2 in 3, type E3 in 3 and type E4 in 1 of the patients according to Strasberg classification. Conclusion: Presenting symptoms of the patients with symptomatic bile duct injury are useful in the determination of the treatment option.

  17. Percutaneous transhepatic cholelithotripsy for difficult common bile duct stones

    DEFF Research Database (Denmark)

    Stage, J G; Moesgaard, F; Grønvall, S

    1998-01-01

    or ureteroscope in ten patients and by stone removal by basket in the remaining four patients. The procedure was carried out using local anesthesia in the last 11 patients. Except for two patients with transient cholangitis, no complications occurred. CONCLUSIONS: Difficult bile duct and intrahepatic stones can...

  18. Experimental study on the particles deposition in the sampling duct

    Energy Technology Data Exchange (ETDEWEB)

    Vendel, J.; Charuau, J. [Institut de Protection et de Surete Nucleaire, Yvette (France)

    1995-02-01

    A high standard of protection against the harmful effects of radioactive aerosol dissemination requires a measurement, as representative as possible, of their concentration. This measurement depends on the techniques used for aerosol sampling and transfer to the detector, as well as on the location of the latter with respect to the potential sources. The aeraulic design of the apparatus is also an important factor. Once collected the aerosol particles often have to travel through a variably shaped duct to the measurement apparatus. This transport is responsible for losses due to the particles deposition on the walls, leading to a distortion on the concentration measurements and a change in the particle size distribution. To estimate and minimize measurement errors it is important to determine the optimal transport conditions when designing a duct; its diameter and material, the radius of curvature of the bends and the flow conditions must be defined in particular. This paper presents an experimental study in order to determine, for each deposition mechanism, the retained fraction, or the deposition velocity for different flow regimes. This study has pointed out that it exists a favourable flow regime for the particle transport through the sampling ducts (2 500 < Re < 5 000). It has been established, for any particle diameters, equations to predict the aerosol penetration in smooth-walled cylindrical metal ducts.

  19. Sonographic and radiologic diagnosis of a pancreatic duct stone

    International Nuclear Information System (INIS)

    Habscheid, W.; Kulke, H.; Heidbreder, E.

    1986-01-01

    A case is reported in which asymptomatic chronic pancreatitis of initially unknown etiology was detected as result of a routine follow-up examination of a patient with membraneproliferative glomerulonephritis. Ultrasound and endoscopic cholangio-pancreatography detected a stone in the major pancreatic duct. The stone was of such size and irregular form that endoscopic extraction was impossible. (orig.) [de

  20. Sonographic and radiologic diagnosis of a pancreatic duct stone

    Energy Technology Data Exchange (ETDEWEB)

    Habscheid, W.; Kulke, H.; Heidbreder, E.

    1986-09-01

    A case is reported in which asymptomatic chronic pancreatitis of initially unknown etiology was detected as result of a routine follow-up examination of a patient with membraneproliferative glomerulonephritis. Ultrasound and endoscopic cholangio-pancreatography detected a stone in the major pancreatic duct. The stone was of such size and irregular form that endoscopic extraction was impossible.

  1. Pattern and outcome of surgical management of nasolachrymal duct ...

    African Journals Online (AJOL)

    The commonest complication noted was stent extrusion before 6 weeks in 17.6% of cases. Conclusion: NLDO was mostly of congenital origin and was characterized by delayed presentation. Patients have good outcome with external DCR. Keywords: Children, dacryocystorhinostomy, naso lachrymal duct, obstruction.

  2. Molecular basis of potassium channels in pancreatic duct epithelial cells

    DEFF Research Database (Denmark)

    Hayashi, M.; Novak, Ivana

    2013-01-01

    Potassium channels regulate excitability, epithelial ion transport, proliferation, and apoptosis. In pancreatic ducts, K channels hyperpolarize the membrane potential and provide the driving force for anion secretion. This review focuses on the molecular candidates of functional K channels...... and pancreatic pathologies, including pancreatitis, cystic fibrosis, and cancer, in which the dysregulation or altered expression of K channels may be of importance....

  3. T-tube vs Primary Common Bile Duct Closure

    Directory of Open Access Journals (Sweden)

    M R Joshi

    2010-09-01

    Full Text Available INTRODUCTION: Closure of the common bile duct over T-tube after exploration is a widely practiced traditional method. However, its use may give rise to many complications. We do primary closure of common bile duct after exploration. Aim of the study is to see the efficacy and safety of the primary closure. METHODS: Study was carried out to compare the results of both the techniques from 2006 to 2009 in the cases proven to have common bile duct stone with or without the features of obstructive jaundice. Post operative hospital stay and morbidities related to both the groups were recorded and analyzed. RESULTS: There were total 71 cases included in the study. Thirty one in T-tube group and 40 in primary closure group. T-tube was removed in most of the cases after three weeks where as average time of drain removal in primary closure group is 5.79 +/-1.79 days. Incidence of retained stone was equal in each group. Major complication in T-tube group is biliary peritonitis in four patients at the time of T-tube removal whereas none of the patient from primary closure group suffered from such major complication. CONCLUSIONS: Primary closure after the common bile duct exploration is safe and it helps to avoid the morbidities related to T-tube. Keywords: Choledocholithiasis, Primary closure, retained stone, T-tube, Ureterorenoscope.

  4. Surgical management of Stenson's duct injury using epidural catheter

    African Journals Online (AJOL)

    2012-07-05

    Jul 5, 2012 ... Successful management of parotid duct injury depends on early diagnosis and appropriate intervention, failing of ... Mansarovar Dental College Hospital and Research Centre,. Kolar Road ... A 42-year-old male patient presented to maxillofacial .... catheter, catgut suture, and pediatric intravascular cannula.

  5. Echinococcal Cyst of the Pancreas with Cystopancreatic Duct Fistula ...

    African Journals Online (AJOL)

    Echinococcal Cyst of the Pancreas with Cystopancreatic. Duct Fistula Successfully Treated by Partial Cystectomy and. Cystogastrostomy. Ahmed Elaffand, Adarsh Vijay1, Samah Mohamed, Hassan Hani Al-Battah1, Ayda Youssef, Ahmed Farahat. INTRODUCTION. Hydatid disease (HD) is a rare endemic disease in.

  6. A pilot study of bendamustine in advanced bile duct cancer.

    Science.gov (United States)

    Schoppmeyer, Konrad; Kreth, Florian; Wiedmann, Marcus; Mössner, Joachim; Preiss, Rainer; Caca, Karel

    2007-07-01

    We performed a pilot study to evaluate the safety and tolerability of bendamustine in patients with advanced hilar bile duct cancer and impaired liver function. Six patients with histologically proven, unresectable adenocarcinoma of the hilar bile duct were treated with bendamustine 140 mg/m intravenously on day 1 of the first cycle and with bendamustine 100 mg/m on days 1 and 2 of the second to fourth cycle. Treatment cycles were repeated every 21 days. Primary endpoint was the safety and tolerability of the treatment; secondary endpoints were response rate, time to progression and overall survival. Transient lymphopenia grade 3 occurred in all six patients. No other grade 3 or 4 toxicities were present. The most common nonhematologic toxicity was mouth dryness grade 2 in six patients. Three patients had stable disease. No partial or complete responses were observed. Median time to progression was 3.3 months; median overall survival was 6 months. Our study demonstrates that bendamustine can be safely administered in patients with hilar bile duct cancer and impaired liver function. A potential role of bendamustine in combination therapies for bile duct cancer will be a subject of further trials.

  7. Heat transfer in an asymmetrically heated duct, 2

    International Nuclear Information System (INIS)

    Satoh, Isao; Kurosaki, Yasuo

    1986-01-01

    The objective of this article is to study theoretically and experimentally the effects of nonuniform heating on turbulent heat transfer characteristics for flow in a horizontal rectangular duct ; a vertical side wall was uniformly heated, and the other wall were insulated. In our theoretical approach, the zero-equation model for turbulent eddy viscosity was employed. The effects of mesh size of finite difference on the calculation results were examined, and some refined compensation for wall temperatures and wall shear stresses by no use of fine mesh were proposed to reduce the calculation time. The heat transfer coefficients in thermally developing region for a nonuniformly heated duct obtained from numerical solutions are larger than the one for uniformly heated case. The buoyancy effects on heat transfer were evaluated. However, it was seen that the secondary flow due to buoyancy force was hardly expected to enhance heat transfer in a turbulent duct flow. Experiments were performed to measure the velocity and temperature profiles in a turbulent duct flow with a nonuniform heated wall. The experimental results were in good agreement with the theoretical ones. (author)

  8. Clinical and cholangiographic evaluation of bile duct carcinoma

    International Nuclear Information System (INIS)

    Park, Yeon Won; Kim, So Seon; Kim, Ho Joon; Joh, Young Duk; Chun, Byung Hee

    1986-01-01

    40 cases of bile duct carcinoma gathered over a 6-year period at Kosin Medical College were reviewed and their clinical and cholangiographic findings were as follows: 1. There were 29 males and 11 females (the ratio of men to women, 2.6:1) ranging from 37 to 74 years of age. The majority (70% of cases) were in 4th and 5th decades. 2. Clinical symptoms and signs: jaundice in 95%, RUQ or epigastric pain in 75%, pruritus in 52.5%, dark urine in 35%, weight loss in 32.5%, fever and chills in 22.5%, clay colored stool in 12.5%, and palpable mass in 12.5%. 3. Lab. findings: elevated serum total bilirubin (above 20.0mg% in 45%, 10.0-19.9mg% in 22.5%, 5.0-9.9mg% in 20%, 1.3-4.9mg% in 5%), elevated alkaline phosphatase in 95%. Clonorchiasis were noted in 17.5%. 4. Histologic findings were adenocarcinoma in most cases. 5. The location of bile duct carcinoma were common hepatic duct in 35%, common bile duct in 32.5%, porta hepatic in 12.5%, junction with cystic duct in 10% and diffuse form in 10%. 6. In 33 cases, PTC or post-operative cholangiographic examination were done. And the most frequent findings were dilatation of the proximal bile duct and abrupt narrowing or complete obstruction of distal lumen. In 27 cases (82%), complete obstruction of bile duct were noted. Attempts were made to analyze the type of obstruction: Constricted type in 39%, Nipple type in 18%, round or flat type (smooth or slightly irregular) in 15%, and serrated type in 9%. Incomplete obstruction were noted in 6 cases (18%). Among them, abrupt narrowing of lumen was noted in 9% and diffuse narrowing in 9%. 7. ERCP was done in 7 cases. Findings were: constricted type in 42.6%, constricted and slightly irregular type in 14.3%, downward convexity in 14.3%, diffuse irregular narrowing in 14.3% and intraluminal filing defect in 14.3%.

  9. Causes and Prevention of Laparoscopic Bile Duct Injuries

    Science.gov (United States)

    Way, Lawrence W.; Stewart, Lygia; Gantert, Walter; Liu, Kingsway; Lee, Crystine M.; Whang, Karen; Hunter, John G.

    2003-01-01

    Objective To apply human performance concepts in an attempt to understand the causes of and prevent laparoscopic bile duct injury. Summary Background Data Powerful conceptual advances have been made in understanding the nature and limits of human performance. Applying these findings in high-risk activities, such as commercial aviation, has allowed the work environment to be restructured to substantially reduce human error. Methods The authors analyzed 252 laparoscopic bile duct injuries according to the principles of the cognitive science of visual perception, judgment, and human error. The injury distribution was class I, 7%; class II, 22%; class III, 61%; and class IV, 10%. The data included operative radiographs, clinical records, and 22 videotapes of original operations. Results The primary cause of error in 97% of cases was a visual perceptual illusion. Faults in technical skill were present in only 3% of injuries. Knowledge and judgment errors were contributory but not primary. Sixty-four injuries (25%) were recognized at the index operation; the surgeon identified the problem early enough to limit the injury in only 15 (6%). In class III injuries the common duct, erroneously believed to be the cystic duct, was deliberately cut. This stemmed from an illusion of object form due to a specific uncommon configuration of the structures and the heuristic nature (unconscious assumptions) of human visual perception. The videotapes showed the persuasiveness of the illusion, and many operative reports described the operation as routine. Class II injuries resulted from a dissection too close to the common hepatic duct. Fundamentally an illusion, it was contributed to in some instances by working too deep in the triangle of Calot. Conclusions These data show that errors leading to laparoscopic bile duct injuries stem principally from misperception, not errors of skill, knowledge, or judgment. The misperception was so compelling that in most cases the surgeon did not

  10. Technology.

    Science.gov (United States)

    Online-Offline, 1998

    1998-01-01

    Focuses on technology, on advances in such areas as aeronautics, electronics, physics, the space sciences, as well as computers and the attendant progress in medicine, robotics, and artificial intelligence. Describes educational resources for elementary and middle school students, including Web sites, CD-ROMs and software, videotapes, books,…

  11. Differentiation of benign and malignant hilar bile duct stenosis.

    Science.gov (United States)

    Liu, Xiaolei; Yang, Zhiying; Tan, Haidong; Shao, Chen; Liu, Liguo; Si, Shuang; Xu, Li; Sun, Yongliang

    2016-06-15

    Failure to differentiate benign and malignant hilar bile duct stenosis may lead to inappropriate treatment. We retrospectively analyzed the methods for differentiation. A total of 53 patients with hilar bile duct stenosis were included, comprising 41 malignant cases (hilar cholangiocarcinoma) and 12 benign cases (six primary sclerosing cholangitis and six IgG4-associated sclerosing cholangitis). Data of clinical histories, laboratory tests, imaging studies, and liver pathologies were collected, and comparison was made between benign and malignant groups. Compared with malignant group, patients in the benign group were more likely to have multiorgan involvement of clinical histories (P < 0.001). There was no difference on bilirubin, liver enzyme, and serum tumor marker between the two groups, whereas serum IgG4 levels were higher in the benign group (P = 0.003). Patients in the benign group were more likely to have pancreatic changes (P < 0.001) and multiple-segmental bile duct stenosis (P < 0.001) on imaging. Compared with the malignant group, patients in the benign group were more likely to show severe periportal inflammation in noninvolved liver (P < 0.001), fibrosis around intrahepatic bile duct (P < 0.001), and more IgG4-positive plasma cells (P < 0.001) on liver pathology. Benign lesion should be considered for patients with history of multiorgan involvement, pancreas changes, or multiple-segmental bile duct stenosis on imaging. Liver biopsy could be helpful for differential diagnosis before surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. [Common bile duct stones: the surgical treatment is always valid].

    Science.gov (United States)

    Nardi, F; Gavelli, A; Dapri, G; Huguet, C

    2004-02-01

    The treatment of common bile duct stones has changed with the new therapeutic techniques, that have replaced the conventional therapy, represented by surgery. Anyway, they could cause some problems, that must be regarded. Therefore, we wish to confirm the importance of the conventional surgery in the management of patients with common bile duct stones. A total of 147 patients were operated for common bile duct stones (73 in emergency and 74 in election). The intraoperative cholangiography was carried out in 141 patients and a choledocoscopy in 130 patients. A drain of Kehr was positioned in 120 patients, a bilio-digestive anastomosis in 26 cases and in 1 case there was a direct suture of the common bile duct without drain. All patients were treated with a short-term antibioticotherapy, protracted to 5 days in the emergency cases. In the patients with the drain of Kehr there was a control cholangiography after 7 days from operation and it was removed after 25 days. The analysis of the results was done dividing the patients according to the age: old and >75 years old. Nobody died during the operation. Complications were 17.4% in the patients >75 years old and 2,6% in the patients old. There were 2 death, in the postoperative period, for the group >75 years old. Cases operated in emergency were 68.1% of "old" patients and 37.2% of "young" patients. The postoperative period was 14.9+/-9.2 days for the "old" group and 10.9+/-5.2 days for the "young" group. The treatment of common bile duct stones is still a surgical treatment, particularly for "old" patients.

  13. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  14. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  15. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  16. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  17. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  18. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  19. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  20. Physics of the current injection process during localized helicity injection

    Science.gov (United States)

    Hinson, Edward Thomas

    An impedance model has been developed for the arc-plasma cathode electron current source used in localized helicity injection tokamak startup. According to this model, a potential double layer (DL) is established between the high-density arc plasma (narc ˜ 1021 m-3) in the electron source, and the less-dense external tokamak edge plasma (nedge ˜ 10 18 m-3) into which current is injected. The DL launches an electron beam at the applied voltage with cross-sectional area close to that of the source aperture: Ainj ≈ 2 cm 2. The injected current, Iinj, increases with applied voltage, Vinj, according to the standard DL scaling, Iinj ˜ V(3/2/ inj), until the more restrictive of two limits to beam density nb arises, producing Iinj ˜ V(1/2/inj), a scaling with beam drift velocity. For low external tokamak edge density nedge, space-charge neutralization of the intense electron beam restricts the injected beam density to nb ˜ nedge. At high Jinj and sufficient edge density, the injected current is limited by expansion of the DL sheath, which leads to nb ˜ narc. Measurements of narc, Iinj , nedge, Vinj, support these predicted scalings, and suggest narc as a viable control actuator for the source impedance. Magnetic probe signals ≈ 300 degrees toroidally from the injection location are consistent with expectations for a gyrating, coherent electron beam with a compact areal cross-section. Technological development of the source has allowed an extension of the favorable Iinj ˜ V(1/2/inj) to higher power without electrical breakdown.

  1. Identification and treatment of variation of extrahepatic bile duct in laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    PENG Lei

    2015-10-01

    Full Text Available ObjectiveTo investigate the identification and treatment of variation of extrahepatic bile duct in laparoscopic cholecystectomy (LC, and to reduce the occurrence of bile duct injury. MethodsThis study included 60 patients who received LC in the People′s Hospital of Caidian District in Wuhan and had structural variation of extrahepatic bile duct found during the operation from January 2012 to January 2014. The clinical data were retrospectively analyzed, and the intraoperative and postoperative conditions were summarized. ResultsDuring operation, cystic duct variation was found in 32 cases, abnormal position of the point where the cystic duct joins the extrahepatic bile duct in 20 cases, the cystic duct and the common hepatic duct having the common wall before joining the common bile duct in 2 cases, aberrant bile duct in the gallbladder bed in 2 cases, and accessory hepatic duct in 4 cases. Fifty-one patients (85% successfully underwent LC; 9 patients (15% were converted to open surgery. All patients finished surgery successfully. There were 2 cases of postoperative complications; one patient developed residual stones in the bile duct, and bile leakage occurred in the other patient at one week after LC, who recovered after reoperation. All patients were cured and discharged, without severe complications such as intraperitoneal hemorrhage, infection, and intestinal injury. ConclusionIdentifying the structural variation of extrahepatic bile duct, dissecting the Calot′s triangle meticulously, and determining the type of variation of extrahepatic bile duct play important roles in LC and significantly reduce the incidence of bile duct injury.

  2. Flow characteristics of developing laminar steady flows in a straight duct connected to a square curved duct

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Hyun Chull [Chosun Univ., Gwangju (Korea, Republic of)

    2005-05-01

    In the present study, the characteristics of developing steady laminar flows of a straight duct connected to a 180 .deg. curved duct were examined in the entrance region through experimental measurement. Flow characteristics such as shear stress distributions, pressure distributions and friction coefficient experimentally in a square cross-sectional straight duct by using the PIV system. For the PIV measurement by particles produced from mosquito coils particles. The experimental data were obtained at 9 points dividing the test sections by 400 mm. Experimental results can be summarized as follows. Critical Reynolds number, Re{sub cr} which indicates transition from laminar steady flow to transition steady flow was 2,150. Shear stress per unit length on the wall was stronger than that in the fully developed flow region. This was attributed to the fact that shear stress and pressure loss in the curvature of a duct were increased. Pressure distributions were gradually decreased irrespective of Reynolds number in the whole test section. This trends were in a good agreement with the reference results. Pipe friction coefficient in the steady state flow region was calculate from method of least squares. The co-relationship between fiction coefficient and Reynolds number was established as follow; {lambda}=56/Re.

  3. Laparoscopic common bile duct exploration: our first 50 cases.

    Science.gov (United States)

    Tan, Ker-Kan; Shelat, Vishalkumar Girishchandra; Liau, Kui-Hin; Chan, Chung-Yip; Ho, Choon-Kiat

    2010-02-01

    Laparoscopic common bile duct exploration (CBDE) is becoming more popular in the management of choledocholithiasis due to improved laparoscopic expertise and advancement in endoscopic technology and equipment. This study aimed to evaluate the safety and short-term outcome of laparoscopic CBDE in a single institution over a 3-year period. A retrospective review of the records of all patients who underwent laparoscopic CBDE in Tan Tock Seng Hospital between January 2006 and September 2008 was conducted. Fifty consecutive patients, with a median age of 60 years (range, 27 to 85) underwent laparoscopic CBDE for choledocholithiasis during the study period. About half of our patients presented as an emergency with acute cholangitis (32.0%) accounting for the majority. A total of 22 (44.0%) patients underwent laparoscopic CBDE as their primary procedure while the remaining 28 (56.0%) were subjected to preoperative ERCP initially. Of the latter group, documented stone clearance was only documented in 5 (17.9%) patients. Laparoscopic CBDE via the transcystic route was performed in 27 (54.0%) patients while another 18 patients (36.0%) had laparoscopic choledochotomy and 1 patient (2.0%) had laparoscopic choledocho-duodenostomy. There were 4 (8.0%) conversions in our series. The median operative time for laparoscopic CBDE via the transcystic route and the laparoscopic choledochotomy were 170 (75-465) and 250 (160-415) minutes, respectively. For the 18 patients who underwent a laparoscopic choledochotomy, T-tube was inserted in 8 (44.4%) patients while an internal biliary stent was placed in 4 (22.2%) with the remaining 6 patients (33.3%) undergoing primary closure of the choledochotomy. The median length of hospital stay was 2 days (range, 1 to 15) with no associated mortality. The main complications (n = 4, 8.0%) included retained CBD stones and biliary leakage. These were treated successfully with postoperative endoscopic retrograde cholangiopancreatography (ERCP) with

  4. Mucocele of the cystic duct remnant after orthotopic liver transplant: a problem revisited.

    Science.gov (United States)

    Chatterjee, Suvadip; Das, Debasish; Hudson, Mark; Bassendine, Margaret Fiona; Scott, John; Oppong, Kofi Ernest; Sen, Gourab; French, Jeremy J

    2011-06-01

    Mucocele of the cystic duct remnant is an uncommon hepatobiliary complication of a liver transplant. Current practice usually involves either excising the cystic duct, or incorporating the distal end of the transected cystic duct into the suture line of the biliary anastomosis to ensure drainage. We report a patient who developed cystic duct remnant mucocele after the latter approach was adopted. We believe that this is likely related to delayed anastomotic stricturing, which prevented draining from the remnant cystic duct. We also discuss the incidence, pathology, investigations, and treatment of this condition.

  5. Bowing-reactivity trends in EBR-II assuming zero-swelling ducts

    International Nuclear Information System (INIS)

    Meneghetti, D.

    1994-01-01

    Predicted trends of duct-bowing reactivities for the Experimental Breeder Reactor II (EBR-II) are correlated with predicted row-wise duct deflections assuming use of idealized zero-void-swelling subassembly ducts. These assume no irradiation induced swellings of ducts but include estimates of the effects of irradiation-creep relaxation of thermally induced bowing stresses. The results illustrate the manners in which at-power creeps may affect subsequent duct deflections at zero power and thereby the trends of the bowing component of a subsequent power reactivity decrement

  6. On Computations of Duct Acoustics with Near Cut-Off Frequency

    Science.gov (United States)

    Dong, Thomas Z.; Povinelli, Louis A.

    1997-01-01

    The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.

  7. Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.

    Science.gov (United States)

    Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru

    2015-01-01

    A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.

  8. Technology for Increasing Geothermal Energy Productivity. Computer Models to Characterize the Chemical Interactions of Geothermal Fluids and Injectates with Reservoir Rocks, Wells, Surface Equipment

    International Nuclear Information System (INIS)

    Nancy Moller Weare

    2006-01-01

    This final report describes the results of a research program we carried out over a five-year (3/1999-9/2004) period with funding from a Department of Energy geothermal FDP grant (DE-FG07-99ID13745) and from other agencies. The goal of research projects in this program were to develop modeling technologies that can increase the understanding of geothermal reservoir chemistry and chemistry-related energy production processes. The ability of computer models to handle many chemical variables and complex interactions makes them an essential tool for building a fundamental understanding of a wide variety of complex geothermal resource and production chemistry. With careful choice of methodology and parameterization, research objectives were to show that chemical models can correctly simulate behavior for the ranges of fluid compositions, formation minerals, temperature and pressure associated with present and near future geothermal systems as well as for the very high PT chemistry of deep resources that is intractable with traditional experimental methods. Our research results successfully met these objectives. We demonstrated that advances in physical chemistry theory can be used to accurately describe the thermodynamics of solid-liquid-gas systems via their free energies for wide ranges of composition (X), temperature and pressure. Eight articles on this work were published in peer-reviewed journals and in conference proceedings. Four are in preparation. Our work has been presented at many workshops and conferences. We also considerably improved our interactive web site (geotherm.ucsd.edu), which was in preliminary form prior to the grant. This site, which includes several model codes treating different XPT conditions, is an effective means to transfer our technologies and is used by the geothermal community and other researchers worldwide. Our models have wide application to many energy related and other important problems (e.g., scaling prediction in petroleum

  9. Technology for Increasing Geothermal Energy Productivity. Computer Models to Characterize the Chemical Interactions of Goethermal Fluids and Injectates with Reservoir Rocks, Wells, Surface Equiptment

    Energy Technology Data Exchange (ETDEWEB)

    Nancy Moller Weare

    2006-07-25

    This final report describes the results of a research program we carried out over a five-year (3/1999-9/2004) period with funding from a Department of Energy geothermal FDP grant (DE-FG07-99ID13745) and from other agencies. The goal of research projects in this program were to develop modeling technologies that can increase the understanding of geothermal reservoir chemistry and chemistry-related energy production processes. The ability of computer models to handle many chemical variables and complex interactions makes them an essential tool for building a fundamental understanding of a wide variety of complex geothermal resource and production chemistry. With careful choice of methodology and parameterization, research objectives were to show that chemical models can correctly simulate behavior for the ranges of fluid compositions, formation minerals, temperature and pressure associated with present and near future geothermal systems as well as for the very high PT chemistry of deep resources that is intractable with traditional experimental methods. Our research results successfully met these objectives. We demonstrated that advances in physical chemistry theory can be used to accurately describe the thermodynamics of solid-liquid-gas systems via their free energies for wide ranges of composition (X), temperature and pressure. Eight articles on this work were published in peer-reviewed journals and in conference proceedings. Four are in preparation. Our work has been presented at many workshops and conferences. We also considerably improved our interactive web site (geotherm.ucsd.edu), which was in preliminary form prior to the grant. This site, which includes several model codes treating different XPT conditions, is an effective means to transfer our technologies and is used by the geothermal community and other researchers worldwide. Our models have wide application to many energy related and other important problems (e.g., scaling prediction in petroleum

  10. Localization of intraductal mass through the ostium of the duct using wire guided ductography technique

    International Nuclear Information System (INIS)

    Aslam, M.

    2014-01-01

    To localize intraductal mass (Papilloma) before surgery Materials Guide wire 10-15 cm length of 2/3-0 Prolene/Surgipro Plastic 26G to 20G I/V cannulas Kopans breast lesion localization hook wire Disposable syringe heaving 2ml non-ionic contrast High intensity light and magnified glass. Methods: Prepare patient in sitting or lying position adjust high intensity light clean the nipple with antiseptic lotion. Elicit the discharge with gentle periareolar pressure or ask the patient to bring the discharge. If the opening with discharge is not clearly visualize use magnified glass or loop. Slowly inserted the wire into the duct orifice, it should pass freely into the duct. Introduce the 26G I/V plastic cannula coaxially over the guide wire and remove the guide wire. Gently inject 0.2-0.4 ml contrast, remove and the syringe and apply stopper. The cannula stopper assembly is secured to the breast with tape. Magnified craniocaudal view of the breast is taken, the 26G cannula removed and bigger length 22/20G cannula gradually passed over the guide wire according to distance of lesion from the ostium. Intraductal mass location is verified the hook wire is replaced with guide wire, the position of hook confirmed by mammographic film. The wire is cut 2cms from the nipple and pt. send to operation theater Results:Hook localization has been successfully carried out in six patients. Conclusion:This is a new method of localization of intraductal mass it enables the surgeon to do microductectomy with minimal cosmetic effects to the breast. (author)

  11. Detection of leaks for radioactive tracer in marine duct for transport of liquefied petroleum gas

    International Nuclear Information System (INIS)

    Robles P, E. F.; Benitez S, J. A.; Torre O, J. de la; Cruz S, E. de la; Molina, G.; Hernandez C, J. E.; Flores M, J. . e mail: efrp@nuclear.inin.mx

    2008-01-01

    In this work the aplication in the oil industry of the technique of radioactive tracer appears for the detection of internal leaks in a submarine duct that gives service as it lines of receipt of liquefied petroleum gas (Gas LP) located in the Mexican coast of the Pacific Ocean. This system of marine pipe is a consistent arrangement of a duct interior of 0.254 m (10 inches) of nominal diameter (N.D.) of steel to the carbon for cryogenic service ASTM A 333, Grade 6, schedule 30, isolated thermally with foam of polyurethane and shielding in a steel tube to the carbon ASTM A 53 Grade A, of 0.508 m (20 inches) N. D., schedule 20, which is recovered by a ballast encircling of concrete of 0.0508 m (2 inches) of thickness, reinforced with mesh metallic, and that 1315 m runs on the marine stratum to a maximum depth of 12.5 m. For the detection of leaks by radiotracer it was used as tracer the radioactive isotope La-140 produced in the TRIGA Mark III Experimental Reactor of the National Institute of Nuclear Research, starting from stable lanthanum nitrate (La(NO 3 ) 3 6H 2 O), with an activity of 100 mCi, the one which after having been made logistics tasks, given very particular sea maneuvers and due to the conditions of the work place, in the interior tube was injected in two subsequent stages to cover both duct senses; from earth and from the marine end respectively, there being used fresh water like transport way and submergible sodium iodide detectors (NaI) for the rake of the La-140. At the end of the journeys of pursuit of the radiotracer, it was determine the presence of three leaks points located in the break area of the marine surf to 360 m, 450 m and 495 m of distance of a reference point located in the beach section named Trap of Devils. (Author)

  12. [Notch signaling pathway participates in the differentiation of hepatic progenitor cells into bile duct epithelial cells and progression of hepatic fibrosis in cholestatic liver fibrosis rat].

    Science.gov (United States)

    Mu, Y P; Zhang, X; Xu, Y; Fan, W W; Li, X W; Chen, J M; Chen, G F; Liu, P

    2017-06-08

    Objective: To investigate differentiation direction of hepatic progenitor cells (HPCs) in cholestatic liver fibrosis (CLF), and the role of Notch signaling pathway in the differentiation of HPCs. Methods: A CLF rat model was established by bile duct ligation (BDL) followed by monitoring changes of Notch signal pathway and the cellular origin of proliferating cholangiocytes. After intraperitoneal injection of DAPT (a Notch signaling inhibitor) after bile duct ligation, the progress of liver fibrosis and the proliferation of cholangiocytes after inhibition of the Notch pathway were analyzed. Results: Data showed that bile duct proliferation gradually increased along with inflammatory cell infiltration and proliferating bile duct cells surrounded by abundant collagen in the BDL group. Immunostaining confirmed markedly increased expression of CK19, OV6, Sox9 and EpCAM. In addition, RT-PCR results showed that Notch signaling pathway was activated significantly. Once the Notch signaling pathway was inhibited by DAPT, bile duct proliferation markedly suppressed along with significantly decreased the mRNA expression of CK19, OV6, Sox9 and EpCAM, compared with BDL group [(10.2±0.7) vs . (22.3±0.8), (7.6±1.5) vs . (18.1±3.7), (1.4±0.4) vs . (4.1±1.1), (1.3±0.3) vs . (5.0±1.4), respectively, P liver fibrosis was also reduced significantly. Conclusion: Notch signaling activation is required for HPCs differentiation into cholangiocytes in CLF and inhibition of the Notch signaling pathway may offer a therapeutic option for treating CLF.

  13. Pancreaticobiliary duct changes of periampullary carcinomas: Quantitative analysis at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Dong Sheng, E-mail: victoryhope@163.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Department of Radiology, No.4 West China Teaching Hospital of Sichuan University, Chengdu 610041 (China); Chen, Wei Xia, E-mail: wxchen25@126.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Wang, Xiao Dong, E-mail: tyfs03yz@163.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Acharya, Riwaz, E-mail: riwaz007@hotmail.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Jiang, Xing Hua, E-mail: 13881865517@163.com [Department of Pathology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China)

    2012-09-15

    Purpose: To quantitatively analyse the pancreaticobiliary duct changes of periampullary carcinomas with volumetric interpolated breath-hold examination (VIBE) and true fast imaging with steady-state precession (true FISP) sequence, and investigate the value of these findings in differentiation and preoperative evaluation. Materials and methods: Magnetic resonance (MR) images of 71 cases of periampullary carcinomas (34 cases of pancreatic head carcinoma, 16 cases of intrapancreatic bile duct carcinoma and 21 cases of ampullary carcinoma) confirmed histopathologically were analysed. The maximum diameter of the common bile duct (CBD) and main pancreatic duct (MPD), dilated pancreaticobiliary duct angle and the distance from the end of the proximal dilated pancreaticobiliary duct to the major papilla were measured. Analysis of variance and the Chi-squared test were performed. Results: These findings showed significant differences among the three subtypes: the distance from the end of proximal dilated pancreaticobiliary duct to the major papilla and pancreaticobiliary duct angle. The distance and the pancreaticobiliary duct angle were least for ampullary carcinoma among the three subtypes. The percentage of dilated CBD was 94.1%, 93.8%, and 100% for pancreatic head carcinoma, intrapancreatic bile duct carcinoma and ampullary carcinoma, respectively. And that for the dilated MPD was 58.8%, 43.8%, and 42.9%, respectively. Conclusion: Quantitative analysis of the pancreaticobiliary ductal system can provide accurate and objective assessment of the pancreaticobiliary duct changes. Although benefit in differential diagnosis is limited, these findings are valuable in preoperative evaluation for both radical resection and palliative surgery.

  14. Change of hepatic volume after selective bile duct ligation: an experimental study in the rabbit

    International Nuclear Information System (INIS)

    Lee, Hye Won; Yoon, Yup; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Oh, Joo Hyeong; Rim, Hyeong Teck; Kim, Youn Wha; Lee, Seok Hwan

    1998-01-01

    To evaluate the role of bile duct obstuction in the development of atrophy of the liver, using an animal model. Seven rabbits were divided into two groups: group 1(n=3D5), in which there was selective bile duct ligation, and group 2(n=3D2), which underwent a sham operation. Each group was evaluated using CT for changes in hepatic volume after selective bile duct ligation or a sham operation. In group I, the diameter of dilated bile duct was measured 2, 4, 8, 12 and 16 weeks after bile duct ligation, while gross and histologic change were evaluated in all cases. In group 1, bile duct dilatation was seen on CT two weeks after selective bile duct ligation, and did not change significantly during follow-up. In four of five cases, CT revealed no evidence of significant atrophy of the involved segment. Pathologic specimens, however, revealed dilatation of the bile duct, periductal fibrosis, infiltration of chronic inflammatory cells, and periportal fibrosis. One of five cases showed segmental liver atrophy after selective bile duct ligation. In addion to the above pathologic findings, there was obstruction of the portal vein by foreign body reaction. In group 2, no evidence of dilated bile duct or liver atrophy was revealed by CT or pathologic specimen after a sham operation. During long-term follow-up of 16 weeks, obstruction of the bile duct did not play a major role in the development of lobar atrophy in the rabbit.=20

  15. The experimental study of radiation injury on bile duct and liver tissue

    International Nuclear Information System (INIS)

    Cao Guiwen; Wang Bin; Sun Yequan; Shao Xueye; Ning Houfa; Sui Shouguang; Wang Xiuchun; Bai Xuming

    2007-01-01

    Objective: To investigate the safety, acceptance and the effective extent of 192 Ir-internal irradiation, providing theoretical guidelines for HC. Methods: Sixteen male healthy hybrid dogs enrolled in the experiment were divided into 4 groups of 4 each. The brachytherapy applicator was introduced from gall bladder into the convergence of cystic duct with common hepatic duct during the operation and a small chip of 1 cm 3 liver tissue was cut off and taken for control later on. The animals in group A-D were irradiated by 192 Ir-internal irradiation with 30 Gy, 40 Gy, 50 Gy arid 60 Gy at the correlative dose points respectively. Animals were put to death after 10 days subsequently, with sampling specimens obtained from radiation cystic duct and the in between liver tissue with the distant cystic duct. The radiation injury of the cystic duct and liver tissue near bile ducts were observed and studied by light microscope and transmission election microscope. Results: By the limit of the safest endurance dose(50 Gy) of Bile duct, unreversed injury of the nuclei of liver cells occurred at 0 to 15 mm from bile duct revealed by transmission electron microscope and light microscope. The whole biliary duct wall would be undergone necrosis with irradiation dose over 60 Gy. Conclusions: Normal bile duct possesses good endurance to 192 Ir-internal irradiation. Within the safest endurance limit of 50 Gy the effective irradiation field could reach 15 mm from the involved bile duct. (authors)

  16. Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sweet, M. L. [Southface Energy Inst., Upper Marlboro, MD (United States); Francisco, A.; Roberts, S. G.

    2016-05-01

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

  17. An evaluation of damping ratios for HVAC duct systems using vibration test data

    International Nuclear Information System (INIS)

    Gunyasu, K.; Horimizu, Y.; Kawakami, A.; Iokibe, H.; Yamazaki, T.

    1988-01-01

    The function of Heating Ventilating Air Conditioning (HVAC) systems must be maintained including HVAC duct systems to keep the operation of safety-related equipment in nuclear power plants during earthquake excitations. Therefore, it is important to carry out seismic design for HVAC duct systems. In the previous aseismic design for HVAC duct systems, the 0.5% damping ratio has been used in Japan. In recent years, vibration tests, held on actual duct systems in nuclear power plants and mockup duct systems were performed in order to investigate damping ratios for HVAC duct systems. Based on the results, it was confirmed that the damping ratio for HVAC duct systems, evaluated from these tests, were much greater than the 0.5% damping ratio used in the previous aseismic design of Japan. The new damping ratio in aseismic design was proposed to be 2.5%. The present paper describes the results of the above mentioned investigation

  18. Characterization of the secondary flow in hexagonal ducts

    Science.gov (United States)

    Marin, O.; Vinuesa, R.; Obabko, A. V.; Schlatter, P.

    2016-12-01

    In this work we report the results of DNSs and LESs of the turbulent flow through hexagonal ducts at friction Reynolds numbers based on centerplane wall shear and duct half-height Reτ,c ≃ 180, 360, and 550. The evolution of the Fanning friction factor f with Re is in very good agreement with experimental measurements. A significant disagreement between the DNS and previous RANS simulations was found in the prediction of the in-plane velocity, and is explained through the inability of the RANS model to properly reproduce the secondary flow present in the hexagon. The kinetic energy of the secondary flow integrated over the cross-sectional area yz decreases with Re in the hexagon, whereas it remains constant with Re in square ducts at comparable Reynolds numbers. Close connection between the values of Reynolds stress u w ¯ on the horizontal wall close to the corner and the interaction of bursting events between the horizontal and inclined walls is found. This interaction leads to the formation of the secondary flow, and is less frequent in the hexagon as Re increases due to the 120∘ aperture of its vertex, whereas in the square duct the 90∘ corner leads to the same level of interaction with increasing Re. Analysis of turbulence statistics at the centerplane and the azimuthal variance of the mean flow and the fluctuations shows a close connection between hexagonal ducts and pipe flows, since the hexagon exhibits near-axisymmetric conditions up to a distance of around 0.15DH measured from its center. Spanwise distributions of wall-shear stress show that in square ducts the 90∘ corner sets the location of a high-speed streak at a distance zv+≃50 from it, whereas in hexagons the 120∘ aperture leads to a shorter distance of zv+≃38 . At these locations the root mean square of the wall-shear stresses exhibits an inflection point, which further shows the connections between the near-wall structures and the large-scale motions in the outer flow.

  19. Technology

    Directory of Open Access Journals (Sweden)

    Xu Jing

    2016-01-01

    Full Text Available The traditional answer card reading method using OMR (Optical Mark Reader, most commonly, OMR special card special use, less versatile, high cost, aiming at the existing problems proposed a method based on pattern recognition of the answer card identification method. Using the method based on Line Segment Detector to detect the tilt of the image, the existence of tilt image rotation correction, and eventually achieve positioning and detection of answers to the answer sheet .Pattern recognition technology for automatic reading, high accuracy, detect faster

  20. CT differentiation of mucin-producing cystic neoplasms of the liver from solitary bile duct cysts.

    Science.gov (United States)

    Kim, Hyoung Jung; Yu, Eun Sil; Byun, Jae Ho; Hong, Seung-Mo; Kim, Kyoung Won; Lee, Jong Seok; Kim, So Yeon

    2014-01-01

    The purpose of this study was to identify the CT features required for differentiating mucin-producing cystic neoplasms of the liver (mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct) from solitary bile duct cysts. CT images of pathologically confirmed mucinous cystic neoplasms (n = 15), cyst-forming intraductal papillary neoplasms of the bile duct (n = 16), and solitary bile duct cysts (n = 31) were reviewed. Analysis of the CT findings included shape, presence of septa, location of septa (peripheral vs central), thickness of septa (thin vs thick), mosaic pattern, mural nodules, intracystic debris, calcification, upstream bile duct dilatation, downstream bile duct dilatation, and communication between a cystic lesion and the bile duct. The maximum size of a cystic lesion and the maximum size of the largest mural nodule were measured. The presence of septa, central septa, mural nodules, upstream bile duct dilatation, and downstream bile duct dilatation were found to be significant CT findings for differentiating mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct from solitary bile duct cysts (p bile duct were 87% (27 of 31) and 87% (27 of 31), respectively. When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively [corrected]. With the use of specific CT criteria, mucin-producing cystic neoplasms of the liver can be differentiated from solitary bile duct cysts with a high degree of accuracy.

  1. CPI-613 in Treating Patients With Advanced or Metastatic Bile Duct Cancer That Cannot Be Removed By Surgery

    Science.gov (United States)

    2018-05-22

    Adult Primary Cholangiocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Metastatic Extrahepatic Bile Duct Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Unresectable Extrahepatic Bile Duct Cancer

  2. The Effect of Turbulences Flow on a Gas-Liquid Mixing Process Downstream of a Curved Duct

    Directory of Open Access Journals (Sweden)

    Abdul Satar Jawad Mohammed

    2018-02-01

    Full Text Available An experimental investigation is carried out on the use of water injection on the humidification process of air with a steady flow that travels during the curved part of a duct with a constant cross section. The naturally generated turbulences will surely aid the mixing process between the injected water droplets and the air to enhance both the mass and heat transfer. The current investigation is regarded as a simulation of the inlet air cooling of the gas turbine which aims to specify the optimum atomizer position on the air cooling by the fogging technique. The experiments were carried out on a (50×50 cm wind tunnel with an average air velocity of (10 m/s. Experiments were conducted in a range of air to water flow ratio between 1000 and 2000, and an ambient temperature in a range of 30° to 50°C. At higher ambient temperature of 45.2oC (DBT, a temperature reduction of 26% and an increase in the relative humidity ratio of 2.13 were recorded at the flow ratio of 1000. Injecting water upward through the range of angles -25° to 75° showed less sensitivity to atomizer location regardless the radial position of the atomizer. This situation is most suitable for using atomizing array across the duct. The central location with tangential spray introduces the critical position for a single-point spray. Such position is promising the optimum atomizer place specified by a radii ratio of (r/rin=3 and tangential orientation to the direction of flow.

  3. Advanced diesel electronic fuel injection and turbocharging

    Science.gov (United States)

    Beck, N. J.; Barkhimer, R. L.; Steinmeyer, D. C.; Kelly, J. E.

    1993-12-01

    The program investigated advanced diesel air charging and fuel injection systems to improve specific power, fuel economy, noise, exhaust emissions, and cold startability. The techniques explored included variable fuel injection rate shaping, variable injection timing, full-authority electronic engine control, turbo-compound cooling, regenerative air circulation as a cold start aid, and variable geometry turbocharging. A Servojet electronic fuel injection system was designed and manufactured for the Cummins VTA-903 engine. A special Servojet twin turbocharger exhaust system was also installed. A series of high speed combustion flame photos was taken using the single cylinder optical engine at Michigan Technological University. Various fuel injection rate shapes and nozzle configurations were evaluated. Single-cylinder bench tests were performed to evaluate regenerative inlet air heating techniques as an aid to cold starting. An exhaust-driven axial cooling air fan was manufactured and tested on the VTA-903 engine.

  4. Gamma-ray streaming in bent ducts and voids

    International Nuclear Information System (INIS)

    Bourdet, L.; Nimal, J.C.; Vergnaud, T.

    1983-05-01

    We have developed an analytical method to calculate gamma-ray streaming through straight ducts and a numerical method to study the gamma propagation in bends or in annular clearances. The whole set allows a rigorous treatment of gamma streaming through bent ducts. In the same time a Monte Carlo method allows to study any form of geometry, by using sophisticated biasing techniques. All these developments are made with a simplified albedo. An easy to use code is also proposed to calculate very general albedos and a code to calculate the dose rate due to reflection in a room. Gamma dose rate albedos are determined for all elements and the energy range which concerns fission reactors

  5. Fire protection of nuclear power plant cable ducts

    International Nuclear Information System (INIS)

    Kandrac, J.; Lukac, L.

    1987-01-01

    Fire protection of cable ducts in the Bohunice and Dukovany V-2 nuclear power plants is of a fourtier type. The first level consists in preventive measures incorporated in the power plant design and layout. The second level consists in early detection and a quick repressive action provided by an electric fire alarm system and a stationary spray system, respectively. Fire partitions and glands represent the third level while special spray, paint and lining materials represent the fourth level of the protection. Briefly discussed are the results of an analysis of the stationary spray system and the effects reducing the efficiency of a fire-fighting action using this system. The analysis showed the need of putting off cable duct fires using mobile facilities in case the stationary spray system cannot cope any longer. (Z.M.). 3 figs., 2 refs

  6. Characterization of turbulent coherent structures in square duct flow

    Science.gov (United States)

    Atzori, Marco; Vinuesa, Ricardo; Lozano-Durán, Adrián; Schlatter, Philipp

    2018-04-01

    This work is aimed at a first characterization of coherent structures in turbulent square duct flows. Coherent structures are defined as connected components in the domain identified as places where a quantity of interest (such as Reynolds stress or vorticity) is larger than a prescribed non-uniform threshold. Firstly, we qualitatively discuss how a percolation analysis can be used to assess the effectiveness of the threshold function, and how it can be affected by statistical uncertainty. Secondly, various physical quantities that are expected to play an important role in the dynamics of the secondary flow of Prandtl’s second kind are studied. Furthermore, a characterization of intense Reynolds-stress events in square duct flow, together with a comparison of their shape for analogous events in channel flow at the same Reynolds number, is presented.

  7. Flow Through a Rectangular-to-Semiannular Diffusing Transition Duct

    Science.gov (United States)

    Foster, Jeff; Wendt, Bruce J.; Reichert, Bruce A.; Okiishi, Theodore H.

    1997-01-01

    Rectangular-to-semiannular diffusing transition ducts are critical inlet components on supersonic airplanes having bifucated engine inlets. This paper documents measured details of the flow through a rectangular-to-semiannular transition duct having an expansion area ratio of 1.53. Three-dimensional velocity vectors and total pressures at the exit plane of the diffuser are presented. Surface oil-flow visualization and surface static pressure data are shown. The tests were conducted with an inlet Mach number of 0.786 and a Reynolds number based on the inlet centerline velocity and exit diameter of 3.2 x 10(exp 6). The measured data are compared with previously published computational results. The ability of vortex generators to reduce circumferential total pressure distortion is demonstrated.

  8. Approximate models for neutral particle transport calculations in ducts

    International Nuclear Information System (INIS)

    Ono, Shizuca

    2000-01-01

    The problem of neutral particle transport in evacuated ducts of arbitrary, but axially uniform, cross-sectional geometry and isotropic reflection at the wall is studied. The model makes use of basis functions to represent the transverse and azimuthal dependences of the particle angular flux in the duct. For the approximation in terms of two basis functions, an improvement in the method is implemented by decomposing the problem into uncollided and collided components. A new quadrature set, more suitable to the problem, is developed and generated by one of the techniques of the constructive theory of orthogonal polynomials. The approximation in terms of three basis functions is developed and implemented to improve the precision of the results. For both models of two and three basis functions, the energy dependence of the problem is introduced through the multigroup formalism. The results of sample problems are compared to literature results and to results of the Monte Carlo code, MCNP. (author)

  9. [Lithiasis of the common bile duct and its treatment].

    Science.gov (United States)

    Boutelier, P

    1995-11-18

    Controversy concerning the most appropriate treatment for a patient with a stone in the main duct almost always leads to an overused conclusion in medical-surgical meeting--laparoscopic and classical surgery are complementary procedures--yet in everyday practice, the gastroenterologist will almost always order a retrograde cholangiogram to confirm the diagnosis and, once the obstacle identified, complete the procedure with an endoscopic sphincterotomy even though many surgeons emphasize its danger. At present few operators are equally experienced in the three major therapeutic options, endoscopy, conventional surgery and laparoscopic surgery, and consequently everybody has a tendency to favour his most proficient technique. Whatever technique is chosen, the aim is to completely remove all gall stones from the main bile duct with a minimum amount of risk and at the most reasonable cost. Careful attention to these three factors should help in weighting the advantages and disadvantages of the different means of management.

  10. Intestinal obstruction caused by omphalomesenteric duct remnant: usefulness of laparoscopy.

    Science.gov (United States)

    Bueno Lledó, J; Serralta Serra, A; Planeéis Roig, M; Dobón Giménez, F; Ibáñez Palacín, F; Rodero Rodero, R

    2003-10-01

    The anomalies related to omphalomesenteric duct remnant constitute an uncommon cause of intestinal obstruction, of which Meckel"s diverticulum and its variants represent the most important clinical presentation. In most cases they are asymptomatic and usually affect young patients. When symptomatic, they usually present episodes of gastrointestinal bleeding or acute abdomen syndromes caused by strangulation of intestinal loops as a result of fibrous intraabdominal remnants or inflammation produced by the diverticulum. In most cases, the unexpected presence of these alterations makes intraoperative diagnosis necessary. Treatment is surgical and consists in exeresis of the diverticulum or the fibrous band causing the clinical picture. We report two cases of persistence of the vitelline duct resolved by laparoscopic approach.

  11. In vivo multiphoton imaging of bile duct ligation

    Science.gov (United States)

    Liu, Yuan; Li, Feng-Chieh; Chen, Hsiao-Chin; Chang, Po-shou; Yang, Shu-Mei; Lee, Hsuan-Shu; Dong, Chen-Yuan

    2008-02-01

    Bile is the exocrine secretion of liver and synthesized by hepatocytes. It is drained into duodenum for the function of digestion or drained into gallbladder for of storage. Bile duct obstruction is a blockage in the tubes that carry bile to the gallbladder and small intestine. However, Bile duct ligation results in the changes of bile acids in serum, liver, urine, and feces1, 2. In this work, we demonstrate a novel technique to image this pathological condition by using a newly developed in vivo imaging system, which includes multiphoton microscopy and intravital hepatic imaging chamber. The images we acquired demonstrate the uptake, processing of 6-CFDA in hepatocytes and excretion of CF in the bile canaliculi. In addition to imaging, we can also measure kinetics of the green fluorescence intensity.

  12. Bilateral endoscopic endonasal marsupialization of nasopalatine duct cyst

    Directory of Open Access Journals (Sweden)

    Yohei Honkura

    2015-02-01

    Full Text Available Nasopalatine duct cysts are the most common non-odontogenic cysts in the maxilla, and are conventionally treated through a sublabial or palatine approach. Recently, the endoscopic approach has been used, but experience is extremely limited. We treated a 29-year-old male with nasopalatine duct cyst by endoscopic marsupialization, but paresthesia of the incisor region occurred after surgery. This paresthesia gradually remitted within 6 months. The nasopalatine nerve, which innervates the upper incisor region, enters two lateral canals separately at the nasal floor and exits the central main canal at the palate. Damage to the bilateral nasopalatine nerves might lead to paresthesia, so we recommend careful examination for nerve fibers during endoscopic surgery, especially if fenestration is performed on both sides.

  13. Laparoscopic Transcystic Common Bile Duct Exploration: Advantages over Laparoscopic Choledochotomy.

    Directory of Open Access Journals (Sweden)

    Qian Feng

    Full Text Available The ideal treatment for choledocholithiasis should be simple, readily available, reliable, minimally invasive and cost-effective for patients. We performed this study to compare the benefits and drawbacks of different laparoscopic approaches (transcystic and choledochotomy for removal of common bile duct stones.A systematic search was implemented for relevant literature using Cochrane, PubMed, Ovid Medline, EMBASE and Wanfang databases. Both the fixed-effects and random-effects models were used to calculate the odds ratio (OR or the mean difference (MD with 95% confidence interval (CI for this study.The meta-analysis included 18 trials involving 2,782 patients. There were no statistically significant differences between laparoscopic choledochotomy for common bile duct exploration (LCCBDE (n = 1,222 and laparoscopic transcystic common bile duct exploration (LTCBDE (n = 1,560 regarding stone clearance (OR 0.73, 95% CI 0.50-1.07; P = 0.11, conversion to other procedures (OR 0.62, 95% CI 0.21-1.79; P = 0.38, total morbidity (OR 1.65, 95% CI 0.92-2.96; P = 0.09, operative time (MD 12.34, 95% CI -0.10-24.78; P = 0.05, and blood loss (MD 1.95, 95% CI -9.56-13.46; P = 0.74. However, the LTCBDE group showed significantly better results for biliary morbidity (OR 4.25, 95% CI 2.30-7.85; P<0.001, hospital stay (MD 2.52, 95% CI 1.29-3.75; P<0.001, and hospital expenses (MD 0.30, 95% CI 0.23-0.37; P<0.001 than the LCCBDE group.LTCBDE is safer than LCCBDE, and is the ideal treatment for common bile duct stones.

  14. Laparoscopic common bile duct exploration. Lessons learned after 200 cases.

    Science.gov (United States)

    Abellán Morcillo, Israel; Qurashi, Kamran; Abrisqueta Carrión, Jesús; Martinez Isla, Alberto

    2014-05-01

    Laparoscopic common bile duct exploration (LCBDE) is a reliable, reproducible and cost-effective treatment for common bile duct stones. Several techniques have been described for choledochotomy closure. To present our experience and the lessons learned in more than 200 cases of LCBDE. Between January 1999 and July 2012, 206 patients with common bile duct stones underwent LCBDE. At the beginning of the series, we performed the closure of the CBD over a T-tube (36 patients), subsequently we favoured closure over an antegrade stent (133 patients) but due to a high incidence of acute pancreatitis in the last 16 patients we have performed primary closure. The 3 closure groups were matched for age and sex. Jaundice was the most frequent presentation. A total of 185 (88,5%) patients underwent choledochotomy whereas in 17 (8,7%) patients the transcystic route was used. The group that underwent choledochotomy had a larger size of stones compared to the transcystic group (9,7 vs 7,6mm). In the stented group we found an 11,6% incidence of pancreatitis and 26,1% of hyperamylasemia. In the primary closure group we found a clear improvement of complications and hospital stay. The increased experience of the surgeon and age (younger than 75) had a positive impact on mortality and morbidity. Primary closure of the common bile duct after LCBDE seems to be superior to closure over a T tube and stents. The learning curve seems to have a positive impact on the outcomes making it a safe and reproducible technique especially for patients aged under 75. Copyright © 2013 AEC. Published by Elsevier Espana. All rights reserved.

  15. Indications and results of pancreatic stump duct occlusion after duodenopancreatectomy.

    Science.gov (United States)

    Alfieri, Sergio; Quero, Giuseppe; Rosa, Fausto; Di Miceli, Dario; Tortorelli, Antonio Pio; Doglietto, Giovanni Battista

    2016-09-01

    Severe post-operative complications after pancreaticoduodenectomy (PD) are largely due to pancreatic fistula onset. The occlusion of the main pancreatic duct using synthetic glue may prevent these complications. Aim of this study is to describe this technique and to report short- and long-term results as well as the post-operative endocrine and exocrine insufficiency. Two hundred and four patients who underwent PD with occlusion of the main pancreatic duct in a period of 15 years were retrospectively analyzed. Post-operative complications and their management were the main aim of the study with particular focus on pancreatic fistula incidence and its treatment. At 1-year follow-up endocrine and exocrine functions were analyzed. We observed a 54 % pancreatic fistula incidence, most of which (77/204 patients) were a grade A fistula with little change in medical management. Twenty-eight patients developed a grade B fistula while only 2 % of patients (5/204) developed a grade C fistula. Nine patients required re-operation, 5 of whom had a post-operative grade C fistula. Post-operative mortality was 3.4 %. At 1-year follow-up, 31 % of patients developed a post-operative diabetes while exocrine insufficiency was encountered in 88 % of patients. The occlusion of the main pancreatic duct after PD can be considered a relatively safe and easy-to-perform procedure. It should be reserved to selected patients, especially in case of soft pancreatic texture and small pancreatic duct and in elderly patients with comorbidities, in whom pancreatic fistula-related complications could be life threatening.

  16. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  17. Collecting duct carcinoma of the kidney : a case report

    OpenAIRE

    Igawa, Mikio; Honda, Satoshi; Yoneda, Tatsuaki; Shiina, Hiroaki; Ishibe, Tomoyuki; Kadena, Hitoshi; Nakamoto, Takahisa; Usui, Tsuguru

    1996-01-01

    We present a case of collecting duct carcinoma of the kidney that is an unusual variant of renal cell carcinoma, whose appearance and behavior are not well established. A 55-year-old man was admitted to our hospital with a left large renal cystic mass detected during a health examination. He had undergone radical nephrectomy under the clinical diagnosis of renal cell carcinoma. Histologically, the tumor was not typical renal cell carcinoma and immunohistochemical study was performed. The tumo...

  18. Modelling the dynamics of the cogeneration power plant gas-air duct

    Directory of Open Access Journals (Sweden)

    Аnatoliy N. Bundyuk

    2014-12-01

    Full Text Available Introducing into wide practice the cogeneration power plants (or CHP is one of promising directions of the Ukrainian small-scale power engineering development. Thermal and electric energy generation using the same fuel kind can increase the overall plant efficiency. That makes it appropriate to use CHPs at compact residential areas, isolated industrial enterprises constituting one complex with staff housing area, at sports complexes, etc. The gas-air duct of the cogeneration power plant has been considered as an object of the diesel-generator shaft velocity control. The developed GAD mathematical model, served to analyze the CHP dynamic characteristics as acceleration curves obtained under different external disturbances in the MathWorks MATLAB environment. According to the electric power generation technology requirements a convenient transition process type has been selected, with subsequent identification of the diesel-generator shaft rotation speed control law.

  19. Papillary bile duct dysplasia in primary sclerosing cholangitis.

    Science.gov (United States)

    Ludwig, J; Wahlstrom, H E; Batts, K P; Wiesner, R H

    1992-06-01

    A 62-year-old man with a 20-year history of chronic ulcerative colitis and a 9-year history of primary sclerosing cholangitis (PSC) underwent orthotopic liver transplantation because of symptoms related to PSC and cholangiographic features compatible with a biliary neoplasm. Study of the excised liver revealed papillary mucosal lesions in the common hepatic duct and the right and left hepatic ducts as well as cholangiectases and other features typically associated with PSC. The papillary lesions consisted of abundant fibrovascular stroma covered by biliary epithelium with low-grade and high-grade dysplasia. Some periductal glands were also dysplastic. These features distinguished papillary dysplasia from classic biliary papillomatosis. Only one focus of microinvasion was found; there were no metastases. Among 60 cases of PSC in whom the entire liver could be studied after orthotopic liver transplantation, this was the only instance of unequivocal dysplasia. However, in one specimen, papillary hyperplasia was found. Detailed macroscopic and microscopic rereview of 23 livers from our patients with the longest history of PSC (range, 5-24 years) failed to reveal any additional cases with dysplasia. It is concluded that (a) papillary mucosal lesions in PSC may represent papillary dysplasia without invasion; (b) these lesions may evolve from papillary hyperplasia; (c) the process may be largely, if not entirely, in situ; and (d) the prevalence of dysplasia and carcinoma of bile ducts may be less than the 7%-9% reported in the literature for malignancies associated with PSC.

  20. Fatigue life prediction of oil ducts under service loads

    Energy Technology Data Exchange (ETDEWEB)

    Meggiolaro, Marco A.; Castro, Jaime T.P. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil)

    2003-07-01

    A methodology to calculate the residual initiation and propagation lives of fatigue cracks in oil pipelines with corrosion-like defects is proposed and applied to predict the residual life of an old duct made of API 5L Gr. B steel, in service for more than 40 years. Since its inauguration, this pipeline has carried several heated products under variable temperatures and pressures. The calculated (nominal) service stresses are very high, due to thermal loads that induce significant bending in curved parts of the duct, with peaks close to the yield strength of the steel. The elastic- plastic fatigue damage at a notch or a corrosion pit root is calculated using the {epsilon}N method, and the effects of surface semi-elliptical cracks in its internal (or external) wall is studied considering appropriate stress intensity factor expressions and the actual service loads. In the presence of surface flaws associated to stress concentration factors of the order of three, a fatigue crack likely will initiate in the pipeline. However, if these surface cracks are small compared to the duct wall thickness, their predicted propagation rates are very low. (author)

  1. Turbulence and secondary motions in square duct flow

    Science.gov (United States)

    Pirozzoli, Sergio; Modesti, Davide; Orlandi, Paolo; Grasso, Francesco

    2017-11-01

    We study turbulent flows in pressure-driven ducts with square cross-section through DNS up to Reτ 1050 . Numerical simulations are carried out over extremely long integration times to get adequate convergence of the flow statistics, and specifically high-fidelity representation of the secondary motions which arise. The intensity of the latter is found to be in the order of 1-2% of the bulk velocity, and unaffected by Reynolds number variations. The smallness of the mean convection terms in the streamwise vorticity equation points to a simple characterization of the secondary flows, which in the asymptotic high-Re regime are found to be approximated with good accuracy by eigenfunctions of the Laplace operator. Despite their effect of redistributing the wall shear stress along the duct perimeter, we find that secondary motions do not have large influence on the mean velocity field, which can be characterized with good accuracy as that resulting from the concurrent effect of four independent flat walls, each controlling a quarter of the flow domain. As a consequence, we find that parametrizations based on the hydraulic diameter concept, and modifications thereof, are successful in predicting the duct friction coefficient. This research was carried out using resources from PRACE EU Grants.

  2. Magnetohydrodynamic flow in ducts with discontinuous electrical insulation

    International Nuclear Information System (INIS)

    Mistrangelo, C.; Bühler, L.

    2015-01-01

    Highlights: • Liquid metal MHD flows in ducts with flow channel inserts. • Study of the influence of local interruption of electrical insulation. • 3D numerical simulations. - Abstract: In liquid metal blankets the interaction of the moving breeder with the intense magnetic field that confines the fusion plasma results in significant modifications of the velocity distribution and increased pressure drop compared to hydrodynamic flows. Those changes are due to the occurrence of electromagnetic forces that slow down the core flow and which are balanced by large driving pressure heads. The resulting magnetohydrodynamic (MHD) pressure losses are proportional to the electric current density induced in the fluid and they can be reduced by electrically decoupling the wall from the liquid metal. For applications to dual coolant blankets it is foreseen to loosely insert electrically insulating liners into the ducts. In long channels the insulation could consist of a number of shorter inserts, which implies a possible local interruption of the insulation. Three dimensional numerical simulations have been performed to investigate MHD flows in electrically well-conducting channels with internal discontinuous insulating inserts. The local jump in the electric conductivity of the duct wall results in induced 3D electric currents and related electromagnetic forces yielding additional pressure losses and increased velocity in boundary layers parallel to the magnetic field.

  3. Acute Cholangitis After Bilioenteric Anastomosis for Bile Duct Injuries.

    Science.gov (United States)

    Ortiz-Brizuela, Edgar; Sifuentes-Osornio, José; Manzur-Sandoval, Daniel; Terán-Ellis, Santiago Mier Y; Ponce-de-León, Sergio; Torres-González, Pedro; Mercado, Miguel Ángel

    2017-10-01

    The study aims to describe the clinical features, microbiology, and associated factors of acute cholangitis (AC) after bilioenteric anastomosis (BEA) for biliary duct injury (BDI). Additionally, we assessed the performance of the Tokyo Guidelines 2013 (TG13) recommendations in these patients. We conducted a case-control study of 524 adults with a history of BEA for BDI from January 2000 to January 2014. A propensity score adjustment was performed for the analysis of the independent role of the main factors identified during the univariate logistic regression procedure. We identified 117 episodes of AC in 70 patients; 51.3% were definitive AC according to the TG13 diagnostic criteria, and 39.3% did not fulfill the imaging criteria of AC. A history of post-operative biliary complications (OR 2.55, 95% CI 1.38-4.70) and the bile duct confluence preservation (OR 0.46, 95% CI 0.24-0.87) were associated with AC. Eighty-nine percent of the microorganisms were Enterobacteriaceae; of them, 28% were extended spectrum β-lactamase (ESBL) producers. AC is a common complication after BEA and must be suspected even in the absence of imaging findings, particulary in patients with a history of post-operative biliary complications, and/or without bile duct confluence preserved. An empirical treatment for ESBL-producing Enterobacteriaceae may be appropriate in patients living in countries with a high rate of bacterial drug resistance.

  4. Cholecystokinin cholescintigraphic findings in the cystic duct syndrome

    International Nuclear Information System (INIS)

    Fink-Bennett, D.; DeRidder, P.; Kolozsi, W.; Gordon, R.; Rapp, J.

    1985-01-01

    Fourteen patients with a cystic duct syndrome (CDS) underwent cholecystokinin (CCK) cholescintigraphy. All patients presented with persistent postprandial right upper quadrant pain and biliary colic. None of the patients had an abnormal oral cholecystography, gallbladder (GB) ultrasound exam or upper GI series. Each patient received 5 mCi of technetium-99m disofenin. When the GB maximally filled, 0.02 microgram/kg CCK was administered (3 min) intravenously. Background corrected gallbladder ejection fractions (GBEFs) were determined every 5 min X 4 by rationing the pre-CCK GB counts minus post-CCK GB counts to pre-CCK GB counts. GBEFs were: 12% (3 patients), 17% (2), 0%, 1.3%, 3%, 4%, 6%, 11%, 14%, 18.5%, and 22% (1 each). All patients underwent a surgical exploration and all had macro- or microscopically abnormal cystic ducts with (12 patients) or without (2 patients) concomitant chronic cholecystitis. No patient with a partially occluded cystic duct with or without concomitant chronic cholecystitis had an ejection fraction that exceeded 22%. In an appropriate clinical setting, a low EF response to CCK should alert the physician to the presence of either chronic acalculous cholecystitis, CDS, or the combination of both

  5. Pulsatile pressure driven rarefied gas flow in long rectangular ducts

    Science.gov (United States)

    Tsimpoukis, Alexandros; Valougeorgis, Dimitris

    2018-04-01

    The pulsatile pressure driven fully developed flow of a rarefied gas through an orthogonal duct is investigated, based on the time-dependent linear Bhatnagar, Gross, and Krook equation, by decomposing the flow into its steady and oscillatory parts. The investigation is focused on the oscillatory part, which is characterized by the gas rarefaction and oscillation parameters, the duct aspect ratio, and the accommodation coefficient. As the oscillation frequency is increased, the amplitude of all macroscopic quantities is decreased, while their phase angle lag is increased reaching the limiting value of π/2. As the gas becomes more rarefied, higher frequencies are needed to trigger this behavior. At small and moderate frequencies, there is a critical degree of gas rarefaction, where a maximum flow rate is obtained. As the duct aspect ratio is decreased and tends to zero, the flow rate and mean wall shear stress amplitudes are increased, while their phase angle lags are slightly affected. The accommodation coefficient has a significant effect on the amplitude and a very weak one on the phase angle of the macroscopic quantities. The computation of the inertia and viscous forces clarifies when the flow consists of only one oscillating viscous region or of two regions, namely, the inviscid piston flow in the core and the oscillating Stokes layer at the wall with the velocity overshooting. Finally, the time average oscillatory pumping power is increased as the oscillation frequency is reduced and its maximum value is one half of the corresponding steady one.

  6. Fully developed magnetohydrodynamic flows in rectangular ducts with insulating walls

    International Nuclear Information System (INIS)

    Molokov, S.; Kernforschungszentrum Karlsruhe GmbH; Shishko, A.

    1993-10-01

    In the first part the effect of magnetic field inclination on the flow structure and the pressure drop is considered. The duct walls are insulating. An asymptotic solution to the problem at high Hartmann numbers is obtained. The results show that for a square duct the increase of the pressure gradient due to the field inclination is negligible (less than 10% for any angle). For blanket relevant values of inclination of up to 10 the deviation of the velocity profile from the slug profile is insignificant. The second part studies the flow in a duct with insulating walls parallel to the magnetic field, while the Hartmann walls are covered by an insulating coating. A new type of the boundary condition is derived, which takes into account finite coating resistance. The effect of the latter on the flow characteristics is studied. An exact solution to the problem is obtained and several approximate formulas for the pressure drop at high Hartmann numbers are presented. (orig./HP) [de

  7. IAEA technical committee meeting on pellet injection

    International Nuclear Information System (INIS)

    1993-01-01

    The IAEA Technical Committee Meeting on Pellet Injection, May 10-12, 1993, at the Japan Atomic Energy Research Institute, Naka, Ibaraki-ken, Japan, was held to review the latest results on pellet injection and its effects on plasma confinement. In particular, topics included in the meeting include (i) pellet ablation and particle fueling results, (ii) pellet injection effects on confinement, including improved confinement modes, edge effects, magnetohydrodynamic activity and impurity transport, and (iii) injector technology and diagnostics using pellets. About 30 experts attended and 23 papers were presented. Refs, figs and tabs

  8. Autoimmune pancreatitis: Assessment of the enhanced duct sign on multiphase contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kawai, Yuichi; Suzuki, Kojiro; Itoh, Shigeki; Takada, Akira; Mori, Yoshine; Naganawa, Shinji

    2012-01-01

    Purpose: To assess the usefulness of the computed tomography (CT) finding of main pancreatic duct (MPD) wall enhancement, termed the “enhanced duct sign”, for diagnosis of autoimmune pancreatitis (AIP) in comparison with diagnosis of pancreatic carcinoma and chronic pancreatitis. Materials and methods: Two radiologists independently evaluated the presence or absence of the enhanced duct sign on multiphase contrast-enhanced CT in patients with AIP (n = 55), pancreatic carcinoma (n = 50), and chronic pancreatitis (n = 50). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of AIP were calculated. In patients demonstrating the enhanced duct sign, additional findings were evaluated by consensus. Results: The enhanced duct sign was more frequently observed in patients with AIP (37/55, 67%) than in patients with pancreatic carcinoma (5/50, 10%) or chronic pancreatitis (0/50, 0%) (P < 0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the finding were 0.67, 0.95, 0.85, 0.88, and 0.84, respectively. In AIP, the lumen within the enhanced duct was completely or partially invisible in 29 of 37 (78%) patients, and the enhanced duct was observed within the affected pancreatic parenchyma in 35 of 37 (95%) patients. In pancreatic carcinoma, the lumen within the enhanced duct was visible in all patients (5/5, 100%), and the enhanced duct was observed downstream of the tumor (5/5, 100%). Conclusion: The enhanced duct sign is highly specific of AIP.

  9. Autoimmune pancreatitis: Assessment of the enhanced duct sign on multiphase contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Yuichi, E-mail: kawai.yuichi@a.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Suzuki, Kojiro, E-mail: kojiro@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Itoh, Shigeki, E-mail: shigeito@nagoya-1st.jrc.or.jp [Department of Diagnostic Radiology, Japan Red Cross Nagoya Daiichi Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya 453-8511 (Japan); Takada, Akira, E-mail: takadaa@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Mori, Yoshine, E-mail: yoshine@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Naganawa, Shinji, E-mail: naganawa@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan)

    2012-11-15

    Purpose: To assess the usefulness of the computed tomography (CT) finding of main pancreatic duct (MPD) wall enhancement, termed the 'enhanced duct sign', for diagnosis of autoimmune pancreatitis (AIP) in comparison with diagnosis of pancreatic carcinoma and chronic pancreatitis. Materials and methods: Two radiologists independently evaluated the presence or absence of the enhanced duct sign on multiphase contrast-enhanced CT in patients with AIP (n = 55), pancreatic carcinoma (n = 50), and chronic pancreatitis (n = 50). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of AIP were calculated. In patients demonstrating the enhanced duct sign, additional findings were evaluated by consensus. Results: The enhanced duct sign was more frequently observed in patients with AIP (37/55, 67%) than in patients with pancreatic carcinoma (5/50, 10%) or chronic pancreatitis (0/50, 0%) (P < 0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the finding were 0.67, 0.95, 0.85, 0.88, and 0.84, respectively. In AIP, the lumen within the enhanced duct was completely or partially invisible in 29 of 37 (78%) patients, and the enhanced duct was observed within the affected pancreatic parenchyma in 35 of 37 (95%) patients. In pancreatic carcinoma, the lumen within the enhanced duct was visible in all patients (5/5, 100%), and the enhanced duct was observed downstream of the tumor (5/5, 100%). Conclusion: The enhanced duct sign is highly specific of AIP.

  10. Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct

    Science.gov (United States)

    Kandula, Max

    2011-01-01

    The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.

  11. Reconstruction of Bile Duct Injury and Defect with the Round Ligament.

    Science.gov (United States)

    Dokmak, Safi; Aussilhou, Béatrice; Ragot, Emilia; Tantardini, Camille; Cauchy, François; Ponsot, Philippe; Belghiti, Jacques; Sauvanet, Alain; Soubrane, Olivier

    2017-09-01

    Lateral injury of the bile duct can occur after cholecystectomy, bile duct dissection, or exploration. If direct repair is not possible, conversion to bilioenteric anastomosis can be needed with the risk of long-term bile duct infections and associated complications. We developed a new surgical technique which consist of reconstructing the bile duct with the round ligament. The vascularized round ligament is completely mobilized until its origin and used for lateral reconstruction of the bile duct to cover the defect. T tube was inserted and removed after few months. Patency of the bile duct was assessed by cholangiography, the liver function test and magnetic resonance imaging (MRI). Two patients aged 33 and 59 years old underwent lateral reconstruction of the bile duct for defects secondary to choledocotomy for stone extraction or during dissection for Mirizzi syndrome. The defects measured 2 and 3 cm and occupied half of the bile duct circumference. The postoperative course was marked by low output biliary fistula resolved spontaneously. In one patient, the T tube was removed at 3 months after surgery and MRI at 9 months showed strictly normal aspect of the bile duct with normal liver function test. The second patient is going very well 2 months after surgery and the T tube is closed. Lateral reconstruction of the bile duct can be safely achieved with the vascularized round ligament. We will extend our indications to tubular reconstruction.

  12. Relationship Between Bile Duct Reconstruction and Complications in Living Donor Liver Transplantation.

    Science.gov (United States)

    Miyagi, S; Kawagishi, N; Kashiwadate, T; Fujio, A; Tokodai, K; Hara, Y; Nakanishi, C; Kamei, T; Ohuchi, N; Satomi, S

    2016-05-01

    In living donor liver transplantation (LDLT), the recipient bile duct is thin and short. Bile duct complications often occur in LDLT, with persistent long-term adverse effects. Recently, we began to perform microsurgical reconstruction of the bile duct. The purpose of this study was to investigate the relationship between bile duct reconstruction methods and complications in LDLT. From 1991 to 2014, we performed 161 LDLTs (pediatric:adult = 90:71; left lobe:right lobe = 95:66). In this study, we retrospectively investigated the initial bile duct complications in LDLT and performed univariate and multivariate analyses to identify the independent risk factors for complications. The most frequent complication was biliary stricture (9.9%), followed by biliary leakage (6.8%). On univariate and multiple logistic regression analysis, the independent risk factors for biliary stricture were bile leakage (P = .0103) and recurrent cholangitis (P = .0077). However, there were no risk factors for biliary leakage on univariate analysis in our study. The reconstruction methods (hepaticojejunostomy or duct-to-duct anastomosis) and reconstruction technique (with or without microsurgery) were not risk factors for biliary stricture and leakage. In this study, the most frequent complication of LDLT was biliary stricture. The independent risk factors for biliary stricture were biliary leakage and recurrent cholangitis. Duct-to-duct anastomosis and microsurgical reconstruction of the bile duct were not risk factors for biliary stricture and leakage. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Synchronous double primary cancers of the extrahepatic bile duct: A case report and literature review.

    Science.gov (United States)

    Nishi, Takeshi; Sato, Yoshitoshi; Hanaoka, Takuya; Takahashi, Takuya; Miura, Hiroshi; Takubo, Kenji

    2018-01-01

    Double cancers of the biliary tract system are rare. Most of these cancers are synchronous double cancers of the gall bladder and bile duct, associated with pancreaticobiliary maljunction (PBM). Synchronous double cancers of the extrahepatic bile duct without PBM are especially rare, and only 4 cases have been reported. A 78-year-old woman was admitted to our hospital for examination of hyperbilirubinemia and liver dysfunction. Contrast-enhanced abdominal computed tomography, Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography revealed 2 stenotic regions in the common bile duct: at its junction with the cystic duct and in the distal bile duct. No findings suggested PBM, such as a markedly long common channel. The diagnosis based on endoscopic brush cytology from both stricture portions was adenocarcinoma. The patient had a pylorus-preserving pancreaticoduodenectomy with regional lymph node resection. Macroscopically, there were 2 stenotic regions at the cystic duct junction and in the distal bile duct. Microscopically, the tumor at the junction of the cystic duct was a well-to-moderately differentiated adenocarcinoma. On the other hand, the tumor of the distal bile duct was a poorly differentiated adenocarcinoma. There was no evidence of communication between these 2 cancers. Double cancers of the extrahepatic bile duct without PBM are very rare. Therefore, an accurate diagnosis prior to surgery is necessary. Furthermore, this rare condition seems to be associated with a poor prognosis. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Involvement of the thoracic duct in liver cirrhosis patients with ascites. Using MR lymphography

    International Nuclear Information System (INIS)

    Kuboyama, Shin-ichi; Ishii, Kunihide; Koga, Hiroyuki

    2003-01-01

    To elucidate whether the morphological changes of the thoracic duct are observed in patients with liver cirrhosis and ascites, the thoracic duct was examined at magnetic resonance (MR) lymphography without contrast agent. In 7 healthy volunteers, the thoracic duct was clearly visualized as an intermittent or continuous straight line along the thoracic aorta (its mean diameter was 3.9 mm). In 20 liver cirrhosis without ascites, its mean diameter was 3.6 mm. In 6 liver cirrhosis with refractory ascites, the thoracic duct was visualized as straight or slightly tortuous and slender line (its mean diameter was 2.5 mm). On the other hand, 7 cases with ascites which respond well to the administration of diuretics showed tortuous and dilated thoracic duct (its mean diameter was 4.3 mm). In cases with refractory ascites, mean diameter of the thoracic duct was significantly reduced, compared with the cases without ascites and with ascites that respond well to the administration of diuretics. Thus, it was found that the morphological differences of the thoracic duct depend on the response to the diuretics in liver cirrhosis patients with ascites. To elucidate whether the morphological changes of the thoracic duct are observed in patients with liver cirrhosis and ascites, the thoracic duct was examined at magnetic resonance lymphography without contrast agent. In cases with refractory ascites, mean diameter of the thoracic duct was significantly reduced, compared with the cases without ascites and with ascites that respond well to the administration of diuretics. (author)

  15. Trypsin level in gallbladder bile and ductitis and width of the cystic duct.

    Science.gov (United States)

    Vracko, J; Wiechel, K L

    2000-01-01

    The change from laparotomy to laparoscopy for cholecystectomy has raised the question of how to manage concomitant bile duct stones. The present-day interest--and controversy--has focused on a transcystic approach reported to be feasible in 66-96% of cases, but without explaining the necessary prerequisite: the widening of the cystic duct. The cystic duct, wide mainly in patients with bile duct stones, has been reported to be highly variable: from strictured to very wide. The present study aims at comparing the trypsin level in the gallbladder bile and the cystic duct morphology and width in patients with and without bile duct stones. A prospective series of 63 gallstone patients, 30 with and 33 without bile duct stones (controls), underwent cholecystectomy and bile duct clearance. The study includes the trypsin level in the gallbladder bile, the width and morphology of the cystic duct, and the size of the gallstones. The patients with bile duct stones had, in contrast to the controls, higher trypsin levels in the gallbladder bile (P extraction feasible.

  16. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    Directory of Open Access Journals (Sweden)

    Xiao-bo Lai

    2011-11-01

    Full Text Available The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the computational fluid dynamics (CFD theories adopted; a three-dimensional fluid model of the duct is established by means of the FLUENT solver of the CFD software. Secondly, with the k-∊ turbulence model of three-dimensional incompressible fluid considered and the PRISO pressure modification algorithm employed, the flow field numerical simulations inside the duct of the robot vacuum cleaner are carried out. Then, the velocity vector plots on the arbitrary plane of the duct flow field are obtained. Finally, an investigation of the dynamic characteristics of the duct flow field is done and defects of the original duct flow field are analysed, the optimisation of the original flow field has then been conducted. Experimental results show that the duct flow field after optimisation can effectively reduce pressure drop, the feasibility as well as the correctness of the theoretical modelling and optimisation approaches are validated.

  17. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    Directory of Open Access Journals (Sweden)

    Xiao-bo Lai

    2011-11-01

    Full Text Available The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the computational fluid dynamics (CFD theories adopted; a three‐dimensional fluid model of the duct is established by means of the FLUENT solver of the CFD software. Secondly, with the k‐ε turbulence model of three‐ dimensional incompressible fluid considered and the PRISO pressure modification algorithm employed, the flow field numerical simulations inside the duct of the robot vacuum cleaner are carried out. Then, the velocity vector plots on the arbitrary plane of the duct flow field are obtained. Finally, an investigation of the dynamic characteristics of the duct flow field is done and defects of the original duct flow field are analysed, the optimisation of the original flow field has then been conducted. Experimental results show that the duct flow field after optimisation can effectively reduce pressure drop, the feasibility as well as the correctness of the theoretical modelling and optimisation approaches are validated.

  18. Heat Transfer Computations of Internal Duct Flows With Combined Hydraulic and Thermal Developing Length

    Science.gov (United States)

    Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.

    1997-01-01

    This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.

  19. Evaluation of a high-temperature burner-duct-recuperator system

    Science.gov (United States)

    1990-07-01

    The U.S. Department of Energy's (DOE) Office of Industrial Technologies (OIT) sponsors research and development (R and D) to improve the energy efficiency of American industry and to provide for fuel flexibility. OIT has funded a multiyear R and D project by the Babcock and Wilcox Company (B and W) to design, fabricate, field test, and evaluate a high-temperature burner-duct-recuperator (HTBDR) system. This ceramic-based recuperator system recovers waste heat from the corrosive, high-temperature (2170 F) flue gas stream of a steel soaking pit to preheat combustion air to as high as 1700 F. The preheated air is supplied to a high-temperature burner. The B and W R and D program, which is now complete, involved several activities, including selecting and evaluating ceramic materials, designing the system, and developing and evaluating the prototype. In addition, a full-scale unit was tested at a B and W steel soaking pit. The full-scale system consisted of a modular single-stage ceramic recuperator, a conventional two-pass metallic recuperator, a high-temperature burner, fans, insulated ducting, and associated controls and instrumentation. The metallic recuperator preheated combustion air to about 750 F before it passed to the ceramic module. This technical case study describes the DOE/B and W recuperator project and highlights the field tests of the full-scale recuperator system. The document makes results of field tests and data analysis available to other researchers and private industry. It discusses project status, summarizes field tests, and reviews the potential effects the technology will have on energy use and system economics.

  20. Assessment of Chronological Effects of Irreversible Electroporation on Hilar Bile Ducts in a Porcine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Woong, E-mail: cooljay@korea.ac.kr; Lu, David S. K., E-mail: dlu@mednet.ucla.edu; Osuagwu, Ferdnand, E-mail: fosuagwu@mednet.ucla.edu; Raman, Steven, E-mail: sraman@mednet.ucla.edu [David Geffen School of Medicine at UCLA, Department of Radiology (United States); Lassman, Charles, E-mail: classman@mednet.ucla.edu [David Geffen School of Medicine at UCLA, Department of Pathology (United States)

    2013-11-07

    PurposeTo evaluate the chronological effects of irreversible electroporation (IRE) on large hilar bile ducts in an in vivo porcine model correlated with computed tomography (CT) cholangiography and histopathology.Materials and MethodsTwelve IRE zones were made along hilar bile ducts intraoperatively under ultrasound (US)-guidance in 11 pigs. Paired electrodes were placed either on opposing sides of the bile duct (straddle [STR]) or both on one side of the bile duct (one-sided [OSD]). The shortest electrode-to-duct distance was classified as periductal (≤2 mm) or nonperiductal (>2 mm). CT cholangiography and laboratory tests were performed before IRE and again at 2 days, 4 weeks, and 8 weeks after IRE. Degree of bile duct injury were graded as follows: grade 0 = no narrowing; grade 1 = ≤50 % duct narrowing; grade 2 = >50 % narrowing without proximal duct dilatation; grade 3 = grade 2 with proximal duct dilatation; and grade 4 = grade 3 with enzyme elevation. Pigs were selected for killing and histopathology at 2 days, 4, and 8 weeks.ResultsNonperiductal electrode placement produced no long-term strictures in 5 of 5 ducts. Periductal electrode placement produced mild narrowing in 6 of 7 ducts: 5 grade 1 and 1 grade 2. None showed increased enzymes. There was no significant difference between STR versus OSD electrode placement. Histopathology showed minor but relatively greater ductal mural changes in narrowed ducts.ConclusionIn the larger hilar ducts, long-term patency and mural integrity appear resistant to IRE damage with the energy deposition used, especially if the electrode is not immediately periductal in position.