  1. CORONARY ANGIOGRAPHY WITH DUAL SOURCE COMPUTED TOMOGRAPHY: INITIAL EXPERIENCE

    Institute of Scientific and Technical Information of China (English)

    Zhu-hua Zhang; Wen-min Zhao; Wen-bin Mou; Li-ren Zhang; Wen-ling Zhu; Qi Miao; Qi Fang; Zheng-yu Jin; Shu-yang Zhang; Song-bai Lin; Dong-jing Li; Ling-yan Kong; Yi-ning Wang; Lan Song; Yun Wang

    2007-01-01

    To explore the scan technique and image quality of coronary angiography with dual source computed tomography (CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients. Calcium scoring with plain scan images as well as multi-planar reconstruction( MPR ), maximum intensity projection (MIP), and volume rendering technique (VRT) reconstruction with enhanced scan images were performed in all cases. The scan technique and post-reconstruction experience was summarized. The image quality was classified as 1 to 4 points, and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6 ± 298.7 (0-3 216. 5). The average heart rate of the enhanced scan was 82.1 ± 16.2 (47-139) bpm. The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method, two or more phases supplemented method, and electrocardiogram editing method. Altogether 8 457 coronary segments were evaluated, among which 97.2% were evaluated as point 1, 1.7% point 2, 0.5% point 3, and0.6% point 4. The coronary segments in 261 cases were completely normal, while 360 segments were diagnosed with < 50% stenosis and 625 segments with ≥50%stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation. Heart rate is not a major source of the artifact, coronary segments can be well shown with single or multiple-phase reconstruction method.

  2. Coronary revascularization treatment based on dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dikkers, R.; Willems, T.P.; Jonge, G.J. de; Zaag-Loonen, H.J. van der; Ooijen, P.M.A. van; Oudkerk, M. [University of Groningen, Department of Radiology, Groningen (Netherlands); University Medical Center, Groningen (Netherlands); Piers, L.H.; Tio, R.A.; Zijlstra, F. [University of Groningen, Department of Cardiology, Groningen (Netherlands); University Medical Center, Groningen (Netherlands)

    2008-09-15

    Therapy advice based on dual-source computed tomography (DSCT) in comparison with coronary angiography (CAG) was investigated and the results evaluated after 1-year follow-up. Thirty-three consecutive patients (mean age 61.9 years) underwent DSCT and CAG and were evaluated independently. In an expert reading (the ''gold standard''), CAG and DSCT examinations were evaluated simultaneously by an experienced radiologist and cardiologist. Based on the presence of significant stenosis and current guidelines, therapy advice was given by all readers blinded from the results of other readings and clinical information. Patients were treated based on a multidisciplinary team evaluation including all clinical information. In comparison with the gold standard, CAG had a higher specificity (91%) and positive predictive value (PPV) (95%) compared with DSCT (82% and 91%, respectively). DSCT had a higher sensitivity (96%) and negative predictive value (NPV) (89%) compared with CAG (91% and 83%, respectively). The DSCT-based therapy advice did not lead to any patient being denied the revascularization they needed according to the multidisciplinary team evaluation. During follow-up, two patients needed additional revascularization. The high NPV for DSCT for revascularization assessment indicates that DSCT could be safely used to select patients benefiting from medical therapy only. (orig.)

  3. Feasibility and accuracy of tissue characterization with dual source computed tomography

    NARCIS (Netherlands)

    Van Abbema, Joanne K.; Van der Schaaf, Arjen; Kristanto, Wisnu; Groen, Jaap M.; Greuter, Marcel J. W.

    2012-01-01

    PURPOSE: To evaluate the feasibility and accuracy of a model for tissue characterization with dual source computed tomography (DSCT). METHODS AND MATERIALS: A model for tissue characterization in CT was used with a parameterization of linear attenuation coefficients. Sixteen chemical substances with

  4. Visualization of anomalous coronary arteries on dual-source computed tomography

    NARCIS (Netherlands)

    de Jonge, G. J.; van Ooijen, P. M. A.; Piers, L. H.; Dikkers, R.; Tio, R. A.; Willems, T. P.; van den Heuvel, A. F. M.; Zijlstra, F.; Oudkerk, M.

    2008-01-01

    The purpose of this study is to assess the capability of dual-source computed tomography (DSCT) in evaluating coronary artery anomalies. Early detection and evaluation of coronary artery anomalies is essential because of their potential association with myocardial ischemia and sudden death. In 16 pa

  5. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Laspas, Fotios; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John (CT and MRI Dept., Hygeia Hospital, Athens (Greece)), e-mail: fotisdimi@yahoo.gr; Tsantioti, Dimitra (Statistician, Hygeia Hospital, Athens (Greece))

    2011-04-15

    Background: Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose: To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods: Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results: Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR =65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion: Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure

  6. Myocardial ischemia evaluation with dual-source computed tomography: comparison with magnetic resonance imaging.

    Science.gov (United States)

    Delgado, Carlos; Vázquez, María; Oca, Roque; Vilar, Manuel; Trinidad, Carmen; Sanmartin, Marcelo

    2013-11-01

    Computed tomography does not accurately determine which coronary lesions lead to myocardial ischemia and consequently further tests are required to evaluate ischemia induction. The aim of this study was to compare diagnostic accuracy between dual-energy computed tomography and magnetic resonance imaging in the assessment of myocardial perfusion and viability in patients suspected of coronary artery disease. A prospective study was performed in 56 consecutive patients (39 men [69.6%]; mean age [standard deviation], 63 [10]; range, 23-81). Computed tomography was performed with the following protocol: 1, adenosine stress perfusion; 2, coronary angiography; and 3, delayed enhancement. Magnetic resonance imaging for the evaluation of stress perfusion and delayed enhancement was performed within 30 days. Two observers in consensus analyzed the perfusion and delayed enhancement images. We studied 952 myocardial segments and 168 vascular territories. In a per-segment analysis, the sensitivity, specificity, and positive and negative predictive values of computed tomography compared with magnetic resonance were 76%, 99%, 89%, and 98% for perfusion defects, and 64%, 99%, 82%, and 99% for delayed enhancement, respectively. In a per-vascular territory analysis, the same measures were 78%, 97%, 86%, and 95% for perfusion defects, and 72%, 99%, 93%, and 97% for delayed enhancement, respectively. The mean radiation dose was 8.2 (2) mSv. Dual-source computed tomography may allow accurate and concomitant evaluation of perfusion defects and myocardial viability and analysis of coronary anatomy. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  7. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    Science.gov (United States)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  8. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy.

    Science.gov (United States)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  9. Quantitative assessment of scatter correction techniques incorporated in next generation dual-source computed tomography

    Science.gov (United States)

    Mobberley, Sean David

    Accurate, cross-scanner assessment of in-vivo air density used to quantitatively assess amount and distribution of emphysema in COPD subjects has remained elusive. Hounsfield units (HU) within tracheal air can be considerably more positive than -1000 HU. With the advent of new dual-source scanners which employ dedicated scatter correction techniques, it is of interest to evaluate how the quantitative measures of lung density compare between dual-source and single-source scan modes. This study has sought to characterize in-vivo and phantom-based air metrics using dual-energy computed tomography technology where the nature of the technology has required adjustments to scatter correction. Anesthetized ovine (N=6), swine (N=13: more human-like rib cage shape), lung phantom and a thoracic phantom were studied using a dual-source MDCT scanner (Siemens Definition Flash. Multiple dual-source dual-energy (DSDE) and single-source (SS) scans taken at different energy levels and scan settings were acquired for direct quantitative comparison. Density histograms were evaluated for the lung, tracheal, water and blood segments. Image data were obtained at 80, 100, 120, and 140 kVp in the SS mode (B35f kernel) and at 80, 100, 140, and 140-Sn (tin filtered) kVp in the DSDE mode (B35f and D30f kernels), in addition to variations in dose, rotation time, and pitch. To minimize the effect of cross-scatter, the phantom scans in the DSDE mode was obtained by reducing the tube current of one of the tubes to its minimum (near zero) value. When using image data obtained in the DSDE mode, the median HU values in the tracheal regions of all animals and the phantom were consistently closer to -1000 HU regardless of reconstruction kernel (chapters 3 and 4). Similarly, HU values of water and blood were consistently closer to their nominal values of 0 HU and 55 HU respectively. When using image data obtained in the SS mode the air CT numbers demonstrated a consistent positive shift of up to 35 HU

  10. Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kirchhoff, S., E-mail: sonja.kirchhoff@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany); Herzog, P., E-mail: peter.herzog@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany); Johnson, T., E-mail: Thorsten.johnson@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany); Boehm, H., E-mail: holger.boehm@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany); Nikolaou, K., E-mail: konstantin.nikolaou@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany); Reiser, M.F., E-mail: maximilian.reiser@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany); Becker, C.H., E-mail: christoph.becker@med.uni-muenchen.d [Institute of Clinical Radiology, University Hospital Munich - Grosshadern, Ludwig Maximilians-Universitaet Muenchen, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich (Germany)

    2010-06-15

    Objective: The radiation exposure of a dual-source-64-channel multi-detector-computed-tomography-scanner (Somatom-Defintion, Siemens, Germany) was assessed in a phantom-study performing coronary-CT-angiography (CTCA) in comparison to patients' data randomly selected from routine scanning. Methods: 240 CT-acquisitions of a computed tomography dose index (CTDI)-phantom (PTW, Freiburg, Germany) were performed using a synthetically generated Electrocardiography (ECG)-signal with variable heart rates (30-180 beats per minute (bpm)). 120 measurements were acquired using continuous tube-output; 120 measurements were performed using ECG-synchronized tube-modulation. The pulsing window was set at minimum duration at 65% of the cardiac cycle between 30 and 75 bpm. From 90-180 bpm the pulsing window was set at 30-70% of the cardiac cycle. Automated pitch adaptation was always used. A comparison between phantom CTDI and two patient groups' CTDI corresponding to the two pulsing groups was performed. Results: Without ECG-tube-modulation CDTI-values were affected by heart-rate-changes resulting in 85.7 mGray (mGy) at 30 and 45 bpm, 65.5 mGy/60 bpm, 54.7 mGy/75 bpm, 46.5 mGy/90 bpm, 34.2 mGy/120 bpm, 27.0 mGy/150 bpm and 22.1 mGy/180 bpm equal to effective doses between 14.5 mSievert (mSv) at 30/45 bpm and 3.6 mSv at 180 bpm. Using ECG-tube-modulation these CTDI-values resulted: 32.6 mGy/30 bpm, 36.6 mGy/45 bpm, 31.4 mGy/60 bpm, 26.8 mGy/75 bpm, 23.7 mGy/90 bpm, 19.4 mGy/120 bpm, 17.2 mGy/150 bpm and 15.6 mGy/180 bpm equal to effective doses between 5.5 mSv at 30 bpm and 2.6 mSv at 180 bpm. Significant CTDI-differences were found between patients with lower/moderate and higher heart rates in comparison to the phantom CTDI-results. Conclusions: Dual source CTCA is particularly dose efficient at high heart rates when automated pitch adaptation, especially in combination with ECG-based tube-modulation is used. However in clinical routine scanning for patients with higher

  11. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, Thomas; Scheffel, Hans; Frauenfelder, Thomas; Desbiolles, Lotus; Leschka, Sebastian; Stolzmann, Paul; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Department of Medical Radiology, Institute of Diagnostic Radiology, Zurich (Switzerland); Seifert, Burkhardt [University of Zurich, Department of Biostatistics, Zurich (Switzerland); Flohr, Thomas G. [Computed Tomography CTE PA, Siemens Medical Solutions, Forchheim (Germany)

    2007-12-15

    The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1{+-}16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1{+-}6 HU comparing right and left coronary artery and 56{+-}9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291{+-}65 HU in the ascending aorta, 334{+-}93 HU in the pulmonary trunk, and 285{+-}66 HU and 268{+-}67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain. (orig.)

  12. Evaluation of global left ventricular function assessment by dual-source computed tomography compared with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vleuten, Pieter A. van der; Tio, Rene A.; Zijlstra, Felix [University Medical Centre Groningen, Thoraxcenter, Department of Cardiology, P.O. Box 30001, Groningen (Netherlands); Jonge, Gonda J. de; Lubbers, Daniel D.; Willems, Tineke P.; Oudkerk, Matthijs [University Medical Centre Groningen, Department of Radiology, Groningen (Netherlands)

    2009-02-15

    Left ventricular (LV) function assessment by dual-source computed tomography (DSCT) was compared with the reference standard method using magnetic resonance imaging (MRI). Accurate assessment of LV function is essential for the prediction of prognosis in cardiac disease. Thirty-four patients undergoing DSCT examination of the heart for various clinical indications underwent MRI after DSCT. Short-axis cine images were reconstructed from the DSCT datasets and were analyzed using a dedicated post-processing software-tool to generate global left ventricular function parameters. Five DSCT datasets were considered to be of insufficient image quality. DSCT showed a small overestimation of end-diastolic and end-systolic volumes of 11.0 ml and 3.5 ml, nrespectively. Myocardial mass assessed by DSCT showed an average underestimation of 0.2 g. DSCT showed a small overestimation of LV ejection fraction (LVEF) of 0.4%-point with a Bland-Altman interval of [-8.67 (0.40) 9.48]. Global LV functional parameters calculated from DSCT datasets acquired in daily clinical practice correlated well with MRI and may be considered interchangeable. However, visual assessment of the image quality of the short-axis cine slices should be performed to detect any artifacts in the DSCT data which could influence accuracy. (orig.)

  13. Visualization of anomalous coronary arteries on dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jonge, G.J. de; Ooijen, P.M.A. van; Dikkers, R.; Willems, T.P.; Oudkerk, M. [University Medical Center Groningen, University of Groningen, Department of Radiology, Hanzeplein 1, P.O. Box 30.001, Groningen (Netherlands); Piers, L.H.; Tio, R.A.; Heuvel, A.F.M. van den; Zijlstra, F. [University Medical Center Groningen, University of Groningen, Department of Cardiology, Groningen (Netherlands)

    2008-11-15

    The purpose of this study is to assess the capability of dual-source computed tomography (DSCT) in evaluating coronary artery anomalies. Early detection and evaluation of coronary artery anomalies is essential because of their potential association with myocardial ischemia and sudden death. In 16 patients (12 men, mean age 50 {+-} 14 years), anomalous coronary arteries were detected on contrast-enhanced DSCT in a patient cohort of 230 individuals (incidence of 7%). Six different types of anomalies were diagnosed (three fistula, four anomalies of the circumflex artery, four anomalous right coronary arteries, three anomalies of the left coronary artery, one absent left main coronary artery, and one left coronary artery arising from the pulmonary trunk). Of the 16 patients, 10 also underwent conventional coronary angiography (CAG). Retrospective evaluation of the CAGs by an experienced interventional cardiologist resulted in a precise diagnosis in 50% of patients. With DSCT, sufficient image quality and exact visualization of the aberrant anatomy were achieved in all patients. Therefore, DSCT seems to be an accurate diagnostic tool for examining the precise origin, course, and shape of aberrant coronary arteries. (orig.)

  14. Comparison of Aortic Valve Area Measured by Magnetic Resonance Imaging and Dual-Source Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bruder, O.; Jochims, M.; Jensen, C.; Sabin, G.V. (Dept. of Cardiology and Angiology, Elisabeth Hospital Essen (Germany)); Hunold, P.; Forsting, M.; Barkhausen, J.; Schlosser, T. (Dept. of Diagnostic and Interventional Radiology and Neuroradiology, Univ. Hospital Essen, Univ. of Duisburg-Essen (Germany))

    2009-07-15

    Background: Aortic valve stenosis is the most common type of valve lesion in Europe and North America. Patient treatment is based on disease severity, which is classified by determining the aortic valve area (AVA). Purpose: To compare dual-source computed tomography (DSCT) with magnetic resonance (MR) imaging for quantifying AVA. Material and Methods: Thirty-two patients, 28 with normal aortic valve function and four with aortic valve stenosis, who underwent DSCT coronary angiography (Somatom Definition; Siemens, Erlangen, Germany), were included in this study. Retrospective ECG-gated contrast-enhanced DSCT scans with dose-reducing tube current modulation were performed, and data sets were reconstructed in 3% steps of the R-R interval (slice thickness 0.75 mm, increment 0.6 mm). Planimetry of the AVA in systole was assessed on cross-sectional images by multiplanar reformations. Within 48 hours, MR was performed with a 1.5T scanner (Magnetom Sonata; Siemens, Erlangen, Germany) using a balanced steady-state free-precession cine sequence (repetition/echo time 3/1.5 ms, flip angle 60 deg, spatial resolution 1.4x1.4 mm2). Cine sequences of the left ventricular outflow tract (LVOT) were obtained in two orthogonal planes, and MR planimetry was performed on cross-sectional images of the aortic valve perpendicular to the LVOT images. Results: AVA assessment by DSCT and MR was feasible in all 32 patients. Mean AVA values determined by DSCT and MR were 4.73+-1.5 cm2 and 4.69+-1.4 cm2, respectively. A strong positive correlation was found between both imaging modalities (R=0.98, P<0.001). Bland-Altman analysis demonstrated an excellent intermodality agreement, with a slight underestimation of AVA by DSCT. The mean difference was -0.04 cm2, with a standard deviation of 0.32 cm2. Conclusion: Retrospective ECG-gated contrast-enhanced DSCT with tube current modulation provides an accurate imaging technique for the assessment of the AVA. Further studies are required to determine

  15. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christoph J., E-mail: c.jensen@contilia.d [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Jochims, Markus [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Hunold, Peter; Forsting, Michael; Barkhausen, Joerg [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany); Sabin, Georg V.; Bruder, Oliver [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Schlosser, Thomas [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany)

    2010-06-15

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 {+-} 8% vs. 64 {+-} 8%, p = 0.47; EDV 136 {+-} 36 ml vs. 138 {+-} 35 ml, p = 0.66; ESV 52 {+-} 21 ml vs. 52 {+-} 22 ml, p = 0.61; SV 83 {+-} 22 ml vs. 87 {+-} 19 ml, p = 0.22; CO 5.4 {+-} 0.9 l/min vs. 5.7 {+-} 1.2 l/min, p = 0.09, LVM 132 {+-} 33 g vs. 132 {+-} 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 {+-} 8% vs. 62 {+-} 9%; SV 73 {+-} 17 ml vs. 81 {+-} 15 ml; CO 5.7 {+-} 1.2 l/min vs. 5.0 {+-} 0.8 l/min; ESV 52 {+-} 27 ml vs. 57 {+-} 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 {+-} 31 g vs. 132 {+-} 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  16. Dual-Source Computed Tomography Evaluation of Children with Congenital Pulmonary Valve Stenosis

    Directory of Open Access Journals (Sweden)

    Sun

    2016-03-01

    Full Text Available Background Despite dual-source computed tomography (DSCT technology has been performed well on adults or infants with heart disease, specific knowledge about children with congenital pulmonary valve stenosis (PS remained to be established. Objectives This original research aimed to establish a professional approach of DSCT performing technology on children and to assess the image quality performed by DSCT to establish a diagnostic evaluation for children with PS. Patients and Methods Ninety-eight children with congenital PS referred to affiliated hospital of Jining medical college were recruited from October 2013 to March 2015. Participants were divided into four groups according to different ages (0 - 1, 1 - 3, 3 - 7, 7 - 14, or three groups according to different heart rates ( 110. Image quality of pulmonary valves was assessed based on a four-point grading scale (1 - 4 points. Those cases achieving a score of ≥ 3 points were selected for further investigation, which played a critical role in our analysis. Correlation analysis was used to identify the effects of age and heart rate on image quality. Additionally, the results evaluated by DSCT were compared with those evaluated from the operation, further confirming the accuracy of DSCT. Results Seventy-two cases (73.4% achieved a score of ≥ 3 points based on pulmonary valve imaging, which were available for further diagnosis. There was a statistically significant difference (P < 0.05 between the four groups except 0 - 1 group and 1 - 3 group, 3 - 7 group and 7 - 14 group, and the image quality of elder group was higher than younger group. Image score was gradually decreased with increased heart rate (F = 19.05, P < 0.01. Heart rate was negatively correlated with pulmonary valve scores (r = -0.391, P < 0.001, while there was no correlation between age and scores (r = 0.185, P = 0.070. The number, shape, commissure, and opening status of pulmonary valves evaluated by DSCT were the same as the

  17. Pre- and postsurgical diagnostics with dual-source computed tomography in cardiac surgery; Einsatz der Dual-source-Computertomographie in der prae- und postoperativen kardiochirurgischen Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, K.; Saam, T.; Rist, C.; Johnson, T.; Reiser, M.F.; Becker, C.R. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Vogt, F.; Oberhoffer, M.; Reichart, B. [Ludwig-Maximilians-Universitaet Muenchen, Herzchirurgische Klinik und Poliklinik, Muenchen (Germany)

    2007-04-15

    The aim of this study was to evaluate the clinical potential of dual-source computed tomography (DSCT) in pre- and postsurgical diagnostics in the field of cardiac surgery. A total of 20 patients underwent DSCT of the heart. This CT system with two rotating X-ray tubes (Somatom Definition, Siemens Medical Solutions, Forchheim, Germany) achieves a temporal resolution of 83 ms and a spatial resolution of 0.4 x 0.4 x 0.4 mm. The patient cohort consisted of two subgroups. In a group of ten patients with known coronary artery disease (CAD), scheduled for bypass surgery (i.e., high pretest likelihood for having significant CAD), the results of DSCT coronary angiography (CTA) and invasive quantitative catheter angiography (QCA) were compared to assess the diagnostic accuracy of DSCT in the detection of significant coronary artery stenoses (>50%). In a second group of ten patients with previous aortic valve replacement (homografts), the valve opening area of the transplanted aortic valve graft was measured by DSCT and compared with echocardiography as a standard of reference to exclude postsurgical restenosis of the valve. Of 150 coronary artery segments depicted by CT, 144 (96%) were classified as ''assessable.'' A significant CAD was known in all patients, and altogether 43 significant stenoses were present according to the results of QCA. Blinded to these results, DSCTA reached a sensitivity and specificity of 95% (41/43) and 93% (103/111), yielding a positive and negative predictive value (PPV, NPV) of 79% (31/39) and 98% (103/105), respectively. In patients with aortic valve homografts, all DSCT datasets were considered as being of diagnostic image quality concerning valve depiction. The planimetric evaluation of the CT data as compared to results of echocardiography showed a significant correlation of the results (r=0.64, p=0.0467). A high-grade valve stenosis (opening area <1.0 cm{sup 2}) could be correctly excluded by DSCT in all patients. Dual-source

  18. Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany)], E-mail: dominik.ketelsen@med.uni-tuebingen.de; Thomas, Christoph; Werner, Matthias; Luetkhoff, Marie H. [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Buchgeister, Markus [Departments of Radiotherapy and Radiooncology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Tsiflikas, Ilias; Reimann, Anja [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Burgstahler, Christof [Department of Cardiology, University Hospital Tuebingen, Ottfried-Mueller-Strasse 10, 72076 Tuebingen (Germany); Brodoefel, Harald; Kopp, Andreas F.; Claussen, Claus D.; Heuschmid, Martin [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany)

    2010-02-15

    Purpose: The aim of the study was to estimate radiation exposure of coronary calcium scoring and angiography using ECG-gated and ECG-triggered dual-source computed tomography. Materials and methods: An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for all dose measurements. Effective dose was calculated according to ICRP 103. Radiation exposure was performed on a dual-source computed tomography (DSCT) scanner with standard protocols for calcium scoring (DSCT-Ca) and coronary angiography (DSCTA) at different heart rates (40-100 beats/min). Furthermore, a scanning protocol with ECG-triggering as well as a standard chest CT scan were evaluated. Results: Depending on gender, heart rate and ECG-pulsing, the effective dose of a complete cardiac DSCT (DSCT-Ca and DSCTA) scan varies from 10.2 to 32.6 mSv. The effective radiation dose increased significantly with lower heart rates (p < 0.035). ECG-pulsing reduced the radiation exposure significantly in DSCTA (p < 0.001). Due to breast tissue in the primary scan range, females' doses showed an increase up to 69.9% compared to males in scan protocols without ECG-pulsing. Prospective ECG-triggered DSCTA resulted in estimated effective doses from 2.8 mSv (males) to 4.1 mSv (females). Conclusion: The ECG-pulsing technique has proven its effectiveness to reduce effective dose in coronary CT angiography and is recommended for all patients with regular heart rates. The patient's heart rate influences the radiation exposure with a significant decrease at higher heart rates. Due to its lower dose, ECG-triggered DSCTA should be implemented for special indications, i.e. for diagnosis of pathologies of the aortic root and the ascending aorta.

  19. Semi-automatic measurement of left ventricular function on dual source computed tomography using five different software tools in comparison with magnetic resonance imaging

    NARCIS (Netherlands)

    de Jonge, G. J.; van der Vleuten, P. A.; Overbosch, J.; Lubbers, D. D.; Jansen-van der Weide, M. C.; Zijlstra, F.; van Ooijen, P. M. A.; Oudkerk, M.

    2011-01-01

    Purpose: To compare left ventricular (LV) function assessment using five different software tools on the same dual source computed tomography (DSCT) datasets with the results of MRI. Materials and methods: Twenty-six patients, undergoing cardiac contrast-enhanced DSCT were included (20 men, mean age

  20. Comparison of (semi-)automatic and manually adjusted measurements of left ventricular function in dual source computed tomography using three different software tools

    NARCIS (Netherlands)

    de Jonge, G. J.; van Ooijen, P. M. A.; Overbosch, J.; Litcheva Gueorguieva, A.; Janssen-van der Weide, M. C.; Oudkerk, M.

    To assess the accuracy of (semi-)automatic measurements of left ventricular (LV) functional parameters in cardiac dual-source computed tomography (DSCT) compared to manually adjusted measurements in three different workstations. Forty patients, who underwent cardiac DSCT, were included (31 men, mean

  1. Semi-automatic measurement of left ventricular function on dual source computed tomography using five different software tools in comparison with magnetic resonance imaging

    NARCIS (Netherlands)

    de Jonge, G. J.; van der Vleuten, P. A.; Overbosch, J.; Lubbers, D. D.; Jansen-van der Weide, M. C.; Zijlstra, F.; van Ooijen, P. M. A.; Oudkerk, M.

    2011-01-01

    Purpose: To compare left ventricular (LV) function assessment using five different software tools on the same dual source computed tomography (DSCT) datasets with the results of MRI. Materials and methods: Twenty-six patients, undergoing cardiac contrast-enhanced DSCT were included (20 men, mean age

  2. Radiation Optimized Dual-source Dual-energy Computed Tomography Pulmonary Angiography: Intra-individual and Inter-individual Comparison.

    Science.gov (United States)

    Li, Xie; Chen, Guo Zhong; Zhao, Yan E; Schoepf, U Joseph; Albrecht, Moritz H; Bickford, Matthew W; Gu, Hai Feng; Zhang, Long Jiang; Lu, Guang Ming

    2017-01-01

    This study aimed to intra-individually and inter-individually compare image quality, radiation dose, and diagnostic accuracy of dual-source dual-energy computed tomography pulmonary angiography (CTPA) protocols in patients with suspected pulmonary embolism (PE). Thirty-three patients with suspected PE underwent initial and follow-up dual-energy CTPA at 80/Sn140 kVp (group A) or 100/Sn140 kVp (group B), which were assigned based on tube voltages. Subjective and objective CTPA image quality and lung perfusion map image quality were evaluated. Diagnostic accuracies of CTPA and perfusion maps were assessed by two radiologists independently. Effective dose (ED) was calculated and compared. Mean computed tomography (CT) values of pulmonary arteries were higher in group A than group B (P = .006). There was no difference in signal-to-noise ratio and contrast-to-noise ratio between the two groups (both P > .05). Interobserver agreement for evaluating subjective image quality of CTPA and color-coded perfusion images was either good (κ = 0.784) or excellent (κ = 0.887). Perfusion defect scores and diagnostic accuracy of CTPA showed no difference between both groups (both P > .05). Effective dose of group A was reduced by 45.8% compared to group B (P energy CTPA with 80/Sn140 kVp allows for sufficient image quality and diagnostic accuracy for detecting PE while substantially reducing radiation dose. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Detection of significant coronary artery stenosis with cardiac dual-source computed tomography angiography in heart transplant recipients.

    Science.gov (United States)

    von Ziegler, Franz; Rümmler, Janine; Kaczmarek, Ingo; Greif, Martin; Schenzle, Jan; Helbig, Susanne; Becker, Christoph; Meiser, Bruno; Becker, Alexander

    2012-10-01

    Present study evaluates clinical feasibility of cardiac dual-source computed tomography angiography (DSCTA) to detect significant coronary stenosis because of chronic allograft vasculopathy (CAV) after heart transplantation (HTX). An overall of 51 consecutive heart transplant recipients (43 men, 8 women, mean age: 52.3 ± 13.6 years) underwent DSCTA 1 ± 2 days before annual routine invasive coronary angiography (ICA). Three patients were excluded from further analysis. Total 714/717 (99.6%) segments in remaining 48 patients were depicted in diagnostic image quality by DSCTA with three vessel segments in two patients being additionally excluded because of motion artefacts. On a segment-based analysis, sensitivity, specificity, and diagnostic accuracy (DA) for detection of significant stenosis were calculated as 100%, 98.9% and 98.9% respectively. On a patient-based evaluation, sensitivity, specificity and DA were 100%, 86.0% and 93.0% respectively for remaining 46 patients. Negative predictive value (NPV) was 100%. DSCTA enables diagnosis and especially the exclusion of significant coronary artery stenosis in patients after HTX with a high NPV. The low rate of excluded vessel segments compared with former studies indicates improvement in image acquisition and robustness of latest scanner technology and thus may make subsequent annual invasive coronary angiography unnecessary. © 2012 The Authors. Transplant International © 2012 European Society for Organ Transplantation.

  4. Image quality analysis to reduce dental artifacts in head and neck imaging with dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, D.; Werner, M.K.; Thomas, C.; Tsiflikas, I.; Reimann, A.; Claussen, C.D.; Heuschmid, M. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Koitschev, A. [Tuebingen Univ. (Germany). Abt. fuer Hals-Nasen-Ohrenheilkunde

    2009-01-15

    Purpose: Important oropharyngeal structures can be superimposed by metallic artifacts due to dental implants. The aim of this study was to compare the image quality of multiplanar reconstructions and an angulated spiral in dual-source computed tomography (DSCT) of the neck. Materials and Methods: Sixty-two patients were included for neck imaging with DSCT. MPRs from an axial dataset and an additional short spiral parallel to the mouth floor were acquired. Leading anatomical structures were then evaluated with respect to the extent to which they were affected by dental artifacts using a visual scale, ranging from 1 (least artifacts) to 4 (most artifacts). Results: In MPR, 87.1 % of anatomical structures had significant artifacts (3.12 {+-} 0.86), while in angulated slices leading anatomical structures of the oropharynx showed negligible artifacts (1.28 {+-} 0.46). The diagnostic growth due to primarily angulated slices concerning artifact severity was significant (p < 0.01). Conclusion: MPRs are not capable of reducing dental artifacts sufficiently. In patients with dental artifacts overlying the anatomical structures of the oropharynx, an additional short angulated spiral parallel to the floor of the mouth is recommended and should be applied for daily routine. As a result of the static gantry design of DSCT, the use of a flexible head holder is essential. (orig.)

  5. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor [University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany)

    2010-08-15

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 {+-} 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI (<25 kg/m{sup 2}: 100 kV, >25 kg/m{sup 2}: 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 {+-} 11.1 bpm, variability 1.0 {+-} 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 {+-} 16.6 bpm, variability 17.9 {+-} 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 {+-} 0.3 and 3.0 {+-} 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  6. Effect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography

    Institute of Scientific and Technical Information of China (English)

    Hamza Sunman; Giray Kabak; Lale Tokgzolu; Ali Oto; Kudret Aytemir; Hikmet Yorgun; Uur Canpolat; Ali Taher; Edis Demiri; Tuncay Hazrolan; Leventahiner; Ergn B.Kaya

    2014-01-01

    Background Multidetector computed tomography (MDCT) coronary angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. The purpose of this study is to investigate the effect of age and coronary plaque calcification on diagnostic accuracy of MDCT. Methods The patients were examined by using dual-source MDCT and conventional coronary angiography. MDCT results were analyzed with regard to the severity (>50%stenosis) and morphology (non-calcified, mixed, or calcified) of coronary atherosclerotic plaques evaluated in a 16-segment model. Results In total, 181 patients (94 men and 87 women) with 2,687 coronary artery segments were examined with MDCT. Ninety three patients were older than 65 years of age (group A, 42 men) and 88 were younger (group B, 52 men). Two-hundred nine coronary artery segments (7.2%) were ex-cluded because of small distal coronary vessel segments and/or motion artifacts. The overall number of segments with non-diagnostic image quality was similar in both groups of patients. Of the 2,687 evaluated segments, 157 (5.8%) were significantly diseased, and 144 of them were correctly detected by MDCT. Diagnostic evaluation showed that the sensitivity, positive predictive value, specificity, and negative pre-dictive value were 89.5%, 62.5%, 96.0%, and 99.2%, respectively in group A, and 95.2%, 64.8%, 97.5%, and 99.8%in group B, respectively. In addition, detailed segment-based analyses in coronary segments with non-calcified, mixed and calcified plaques in both groups were simi-lar diagnostic accuracy. Conclusions Very high diagnostic accuracy observed in this study suggests that MDCT coronary angiography could be a suitable diagnostic tool for not only younger patients but also for older patients.

  7. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography.

    Science.gov (United States)

    May, Matthias S; Wüst, Wolfgang; Brand, Michael; Stahl, Christian; Allmendinger, Thomas; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2011-07-01

    We sought to evaluate the image quality of iterative reconstruction in image space (IRIS) in half-dose (HD) datasets compared with full-dose (FD) and HD filtered back projection (FBP) reconstruction in abdominal computed tomography (CT). To acquire data with FD and HD simultaneously, contrast-enhanced abdominal CT was performed with a dual-source CT system, both tubes operating at 120 kV, 100 ref.mAs, and pitch 0.8. Three different image datasets were reconstructed from the raw data: Standard FD images applying FBP which served as reference, HD images applying FBP and HD images applying IRIS. For the HD data sets, only data from 1 tube detector-system was used. Quantitative image quality analysis was performed by measuring image noise in tissue and air. Qualitative image quality was evaluated according to the European Guidelines on Quality criteria for CT. Additional assessment of artifacts, lesion conspicuity, and edge sharpness was performed. : Image noise in soft tissue was substantially decreased in HD-IRIS (-3.4 HU, -22%) and increased in HD-FBP (+6.2 HU, +39%) images when compared with the reference (mean noise, 15.9 HU). No significant differences between the FD-FBP and HD-IRIS images were found for the visually sharp anatomic reproduction, overall diagnostic acceptability (P = 0.923), lesion conspicuity (P = 0.592), and edge sharpness (P = 0.589), while HD-FBP was rated inferior. Streak artifacts and beam hardening was significantly more prominent in HD-FBP while HD-IRIS images exhibited a slightly different noise pattern. Direct intrapatient comparison of standard FD body protocols and HD-IRIS reconstruction suggest that the latest iterative reconstruction algorithms allow for approximately 50% dose reduction without deterioration of the high image quality necessary for confident diagnosis.

  8. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Bak, So Hyeon; Jeon, Hae Jeong (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Ko, Sung Min (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of); Research Inst. of Medical Science, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)), Email: 20070437@kuh.ac.kr; Yang, Hyun Suk; Hwang, Hweung Kon (Dept. of Cardiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Song, Meong Gun (Dept. of Thoracic Surgery, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of))

    2012-04-15

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV

  9. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution : A cardiac phantom study

    NARCIS (Netherlands)

    Greuter, M. J. W.; Groen, J. M.; Nicolai, L. J.; Dijkstra, H.; Oudkerk, M.

    2009-01-01

    Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative me

  10. Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beitzke, D.; Berger-Kulemann, V.; Unterhumer, S.; Loewe, C.; Wolf, F. [Medical University Vienna, Department of Biomedical Imaging and Image Guided Therapy, Division of Cardiovascular and Interventional Radiology, Vienna (Austria); Schoepf, V. [Medical University Vienna, Department of Biomedical Imaging and Image Guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Spitzer, E. [Bern University Hospital, Department of Cardiology, Bern (Switzerland); Feuchtner, G.M. [Innsbruck Medical University, Department of Radiology II, Innsbruck (Austria); Gyoengyoesi, M. [Medical University Vienna, Department of Cardiology, Vienna (Austria); Uyanik-Uenal, K.; Zuckermann, A. [Medical University Vienna, Department of Cardiac Surgery, Vienna (Austria)

    2015-08-15

    To prospectively evaluate image quality (IQ) and radiation dose of dual-source cardiac computed tomography (CCTA) using different imaging protocols. CCTA was performed in 150 patients using the retrospective ECG-gated spiral technique (rECG) the prospective ECG-gated technique (pECG), or the prospective ECG-gated technique with systolic imaging and automated tube voltage selection (pECGsys). IQ was rated using a 16-segment coronary artery model. Techniques were compared for overall IQ, IQ of the large and the small coronary artery segments. Effective dose was used for comparison of radiation dose. Overall IQ and IQ of the large segments showed no differences between the groups. IQ analysis of the small segments showed lowered IQ in pECGsys compared to rECG (p = 0.02), but not to pECG (p = 0.6). Effective dose did not differ significantly between rECG and pECG (p = 0.13), but was significantly lower for pECGsys (p < 0.001 vs. rECG and pECG). Radiation dose of dual-source CCTA in heart transplant recipients is significantly reduced by using prospective systolic scanning and automated tube voltage selection, while overall IQ and IQ of the large coronary segments are maintained. IQ appears to be lower compared to retrospective techniques with regard to small coronary segments. (orig.)

  11. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Rui, E-mail: rui_wang1979@yahoo.cn [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Qin, E-mail: tel1367@gmail.com [Department of Emergency, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); He Yi, E-mail: heyi139@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lu Dongxu, E-mail: larry.hi@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2011-11-15

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 {+-} 9.57 HU vs. 72.63 {+-} 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 {+-} 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  12. Application of dual-source-computed tomography in pediatric cardiology in children within the first year of life; Einsatz der Dual-Source-Computertomografie in der Kinderkardiologie bei Kindern im ersten Lebensjahr

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, P.; Stenger, A.; Dittrich, S.; Gloeckler, M. [Erlangen-Nuernberg Univ., Erlangen (Germany). Pediatric Cardiology; Cesnjevar, R.; Rueffer, A. [Erlangen-Nuernberg Univ., Erlangen (Germany). Congenital Heart Surgery; Hammon, M.; Uder, M.; Rompel, O. [Erlangen-Nuernberg Univ., Erlangen (Germany). Radiology

    2016-02-15

    To assess fields of application and value of dual source computed tomography (DSCT) for diagnostics and therapy in patients with congenital heart disease during their first year of life. Evaluation of image quality, surgical use and radiation exposure of 2nd and 3rd generation DSCT. DSCT was applied in 118 cases between January 2012 and October 2014 for diagnostics of congenital heart defects. 2nd generation was used in 91 cases until April 2014 and 3rd generation in 27 cases during the period thereafter. 3D reconstructions of the image data were created for clinical diagnostics and planning of interventions. Image quality was assessed using a 4-point-scale. The visibility of the mammary arteries was analyzed, and signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. The usefulness of 3D-reconstructions for surgical planning was rated using a 5-point-scale. Radiation exposure and contrast dye consumption were determined. All cases were analyzed retrospectively. DSCT was successfully used in 118 cases. All image data obtained were interpretable. More than 60 percent of cases did not show any artifacts. The mammary arteries were visible down to the diaphragmatic arch in more than 80 percent of cases. Diagnostic value and surgical benefit were evaluated as ''useful'' or as ''essential'' in all cases. Median radiation dose was 0.4 mSv and 0.27 mSv for the 2nd and 3rd generation DSCT, respectively. Consumption of contrast dye was 2 ml/kg in all cases. DSCT is a modern and extremely helpful technique for diagnostics and planning of interventions in patients with complex congenital heart defects. Extracardiac vascular structures in particular can be depicted three-dimensionally at high resolution. The use of iterative reconstruction with 3rd generation DSCT yielded image quality similar to that of 2nd generation DSCT at considerably reduced radiation exposure level compared to 2nd generation DSCT. 3rd

  13. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    Energy Technology Data Exchange (ETDEWEB)

    Felmly, Lloyd M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiothoracic Surgery, Department of Surgery, Charleston, SC (United States); De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-05-15

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m{sup 2} vs. 28.1±5.4 kg/m{sup 2}, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  14. Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis

    Institute of Scientific and Technical Information of China (English)

    Liang Zhu

    2014-01-01

    Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography (DSCT) with sinogram affirmed iterative reconstruction (SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans (protocol 1) [tube voltage of 120 kVp/pitch of 0.9/filtered back-projection (FBP) reconstruction] followed by high-pitch non-enhanced CT scans (protocol 2) (100 kVp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio (SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1 (1.4±0.1 seconds vs. 7.6±0.6 seconds, P Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.

  15. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael [University of Erlangen, Department of Radiology, Erlangen (Germany); Deak, Paul; Kalender, Willi A. [University of Erlangen, Department of Medical Physics, Erlangen (Germany); Keller, Andrea K.; Haeberle, Lothar [University of Erlangen, Department of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Achenbach, Stephan; Seltmann, Martin [University of Erlangen, Department of Cardiology, Erlangen (Germany)

    2012-03-15

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 {+-} 2.1 mSv/100 mAs for TCM and 12.5 {+-} 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR ({<=}60 bpm) was highest (49 {+-} 5%) compared to intermediate (60-70 bpm, 33 {+-} 12%) and high HR (>70 bpm, 29 {+-} 12%). However lowest ED is achieved at high HR (5.2 {+-} 1.5 mSv/100 mAs), compared with intermediate (6.7 {+-} 1.6 mSv/100 mAs) and low (8.3 {+-} 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  16. Carotid and cerebrovascular disease in symptomatic patients with type 2 diabetes: assessment of prevalence and plaque morphology by dual-source computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Deng Wen

    2010-12-01

    Full Text Available Abstract Background Plaque morphology directly correlates with risk of embolism and the recently developed dual-source computed tomography angiography (DSCTA may help to detect plaques more precisely. The aim of our study was to evaluate the prevalence and morphology of carotid and cerebrovascular atherosclerotic plaques in patients with symptomatic type 2 diabetes mellitus (DM by DSCTA. Methods From July 2009 to August 2010, DSCTA was prospectively performed in 125 consecutive patients with symptomatic type 2 DM. We retrospectively analyzed plaque type, distribution, and extensive and obstructive natures were determined for each segment for all patients. Results Atherosclerotic plaques were detected in 114 (91.2% patients. Relatively more noncalcified (45% and calcified (39% plaques and less mixed (16% plaques were observed (p st to 5th segments was observed in 67 (58.8% patients and from the 6th to 10th segments in 35 (30.7% patients. The most common site of all detected plaques was the cavernous segment. Regarding stenosis, there were significantly more nonobstructive than obstructive stenosis (91% vs. 9%, p Conclusion DSCTA detected a high prevalence of plaques in patients with symptomatic type 2 DM. A relatively high proportion of plaques were noncalcified, as well as with nonobstructive stenosis. The distribution of plaques was extensive, with the cavernous portion of ICA being the most common site.

  17. Accuracy and variability of right ventricular volumes and mass assessed by dual-source computed tomography: influence of slice orientation in comparison to magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christoph J. [Elisabeth Hospital Essen, Department of Cardiology and Angiology, Essen (Germany); Duke University Medical Center, Duke Cardiovascular Magnetic Resonance Center, Durham, NC (United States); Wolf, Alexander; Eberle, Holger C.; Sabin, Georg V.; Bruder, Oliver [Elisabeth Hospital Essen, Department of Cardiology and Angiology, Essen (Germany); Forsting, Michael; Nassenstein, Kai; Lauenstein, Thomas C.; Schlosser, Thomas [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2011-12-15

    To evaluate the accuracy and variability of right ventricular (RV) volumes and mass using dual-source computed tomography (DSCT) and the influence of slice orientation in comparison to cardiac magnetic resonance imaging (CMR). In 33 patients undergoing cardiac DSCT and CMR, RV parameters were calculated using the short-axis (DSCT, CMR) and axial orientation (DSCT). Intra- and interobserver variability were assessed by Bland-Altman analysis. Short-axis orientation: RV parameters of the two techniques were not statistically different. Axial orientation: RV volumes and mass were significantly overestimated compared with short-axis parameters whereas EF was similar. The short-axis approach resulted in low variability, although the axial orientation had the least amount of intra- and interobserver variability. RV parameters can be more accurately assessed by DSCT compared with CMR using short-axis slice orientation. RV volumes and mass are significantly higher using axial compared with short-axis slices, whereas EF is unaffected. RV parameters derived from both approaches yield high reproducibility. (orig.)

  18. Effect of the high-pitch mode in dual-source computed tomography on the accuracy of three-dimensional volumetry of solid pulmonary nodules: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Ho; Oh, Yu Whan; Ham, Soo Youn [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Ki Yeol [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2015-06-15

    To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 +/- 0.9%, and 1.7 +/- 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 +/- 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 +/- 5.3%), with an IVV of 13.1 +/- 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule.

  19. Quantification of left coronary bifurcation angles and plaques by coronary computed tomography angiography for prediction of significant coronary stenosis: A preliminary study with dual-source CT

    Science.gov (United States)

    Cui, Yue; Zeng, Wenjuan; Yu, Jie; Lu, Jing; Hu, Yuannan; Diao, Nan; Liang, Bo; Han, Ping; Shi, Heshui

    2017-01-01

    Purpose To evaluate the diagnostic performance of left coronary bifurcation angles and plaque characteristics for prediction of coronary stenosis by dual-source CT. Methods 106 patients suspected of coronary artery disease undergoing both coronary computed tomography angiography (CCTA) and invasive coronary angiography (CAG) within three months were included. Left coronary bifurcation angles including the angles between the left anterior descending artery and left circumflex artery (LAD-LCx), left main coronary artery and left anterior descending artery (LM-LAD), left main coronary artery and left circumflex artery (LM-LCx) were measured on CT images. CCTA plaque parameters were calculated by plaque analysis software. Coronary stenosis ≥ 50% by CAG was defined as significant. Results 106 patients with 318 left coronary bifurcation angles and 126 vessels were analyzed. The bifurcation angle of LAD-LCx was significantly larger in left coronary stenosis ≥ 50% than stenosis coronary stenosis (OR = 1.423, P = 0.002). In ROC curve analysis, LAD-LCx predicted significant left coronary stenosis with a sensitivity of 66.7%, specificity of 78.4%, positive predictive value of 85.2% and negative predictive value of 55.8%. The lipid plaque volume improved the diagnostic performance of CCTA diameter stenosis (AUC: 0.854 vs. 0.900, P = 0.045) in significant coronary stenosis. Conclusions The bifurcation angle of LAD-LCx could predict significant left coronary stenosis. Wider LAD-LCx is related to non-calcified lesions. Lipid plaque volume could improve the diagnostic performance of CCTA for coronary stenosis prediction. PMID:28346530

  20. Computed Tomography of the Head and Neck Region for Tumor Staging-Comparison of Dual-Source, Dual-Energy and Low-Kilovolt, Single-Energy Acquisitions.

    Science.gov (United States)

    May, Matthias Stefan; Bruegel, Joscha; Brand, Michael; Wiesmueller, Marco; Krauss, Bernhard; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang

    2017-09-01

    The aim of this study was to intra-individually compare the image quality obtained by dual-source, dual-energy (DSDE) computed tomography (CT) examinations and different virtual monoenergetic reconstructions to a low single-energy (SE) scan. Third-generation DSDE-CT was performed in 49 patients with histologically proven malignant disease of the head and neck region. Weighted average images (WAIs) and virtual monoenergetic images (VMIs) for low (40 and 60 keV) and high (120 and 190 keV) energies were reconstructed. A second scan aligned to the jaw, covering the oral cavity, was performed for every patient to reduce artifacts caused by dental hardware using a SE-CT protocol with 70-kV tube voltages and matching radiation dose settings. Objective image quality was evaluated by calculating contrast-to-noise ratios. Subjective image quality was evaluated by experienced radiologists. Highest contrast-to-noise ratios for vessel and tumor attenuation were obtained in 40-keV VMI (all P VMI, WAI, and the 70-kV SE examinations. Overall subjective image quality was also highest for 40-keV, but differences to 60-keV VMI, WAI, and 70-kV SE were nonsignificant (all P > 0.05). High kiloelectron volt VMIs reduce metal artifacts with only limited diagnostic impact because of insufficiency in case of severe dental hardware. CTDIvol did not differ significantly between both examination protocols (DSDE: 18.6 mGy; 70-kV SE: 19.4 mGy; P = 0.10). High overall image quality for tumor delineation in head and neck imaging were obtained with 40-keV VMI. However, 70-kV SE examinations are an alternative and modified projections aligned to the jaw are recommended in case of severe artifacts caused by dental hardware.

  1. Semi-automatic measurement of left ventricular function on dual source computed tomography using five different software tools in comparison with magnetic resonance imaging.

    Science.gov (United States)

    de Jonge, G J; van der Vleuten, P A; Overbosch, J; Lubbers, D D; Jansen-van der Weide, M C; Zijlstra, F; van Ooijen, P M A; Oudkerk, M

    2011-12-01

    To compare left ventricular (LV) function assessment using five different software tools on the same dual source computed tomography (DSCT) datasets with the results of MRI. Twenty-six patients, undergoing cardiac contrast-enhanced DSCT were included (20 men, mean age 59±12 years). Reconstructions were made at every 10% of the RR-interval. Function analysis was performed with five different, commercially available workstations. In all software tools, semi-automatic LV function measurements were performed, with manual corrections if necessary. Within 0-22 days, all 26 patients were scanned on a 1.5 T MRI-system. Bland-Altman analysis was performed to calculate limits of agreement between DSCT and MRI. Pearson's correlation coefficient was calculated to assess the correlation between the different DSCT software tools and MRI. Repeated measurements were performed to determine intraobserver and interobserver variability. For all five DSCT workstations, mean LV functional parameters correlated well with measurements on MRI. Bland-Altman analysis of the comparison of DSCT and MRI showed acceptable limits of agreement. Best correlation and limits of agreement were obtained by DSCT software tools with software algorithms comparable to MRI software. The five different DSCT software tools we examined have interchangeable results of LV functional parameters compared to regularly analysed results by MRI. The best correlation and the narrowest limits of agreement were found when the same software algorithm was used for both DSCT and MRI examinations, therefore our advice for clinical practice is to always evaluate images with the same type of post-processing tools in follow-up. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch

    Institute of Scientific and Technical Information of China (English)

    Hai-Ou Li; Xi-Ming Wang; Pei Nie; Xiao-Peng Ji; Zhao-Ping Cheng; Jiu-Hong Chen; Zhuo-Dong Xu

    2015-01-01

    Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA.Methods:Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE).Surgery was performed on all the patients.A five-point scale was used to assess image quality.The diagnostic accuracy ofDSCT angiography and TTE was compared with the surgical findings as the reference standard.A nonparametric Chi-square test was used for comparative analysis.P<0.05 was considered as a significant difference.The mean effective radiation dose (ED) was calculated.Results:Diagnostic DSCT images were obtained for all the patients.Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings.The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P>0.05),and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05),respectively.The mean score of image quality was 3.77 ± 0.83.The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv).Conclusions:In infants and children with IAA,prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.

  3. Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Ke Shi

    Full Text Available To evaluate the feasibility and diagnostic accuracy of retrospective electrocardiographically (ECG-gated dual-source computed tomography (DSCT for the assessment of double outlet right ventricle (DORV and associated multiple malformations in pediatric patients.Forty-seven patients <10 years of age with DORV underwent retrospective ECG-gated DSCT. The location of the ventricular septal defect (VSD, alignment of the two great arteries, and associated malformations were assessed. The feasibility of retrospective ECG-gated DSCT in pediatric patients was assessed, the image quality of DSCT and the agreement of the diagnosis of associated malformations between DSCT and transthoracic echocardiography (TTE were evaluated, the diagnostic accuracies of DSCT and TTE were referred to surgical results, and the effective doses were calculated.Apart from DORV, 109 associated malformations were confirmed postoperatively. There was excellent agreement (κ = 0.90 for the diagnosis of associated malformations between DSCT and TTE. However, DSCT was superior to TTE in demonstrating paracardiac anomalies (sensitivity, coronary artery anomalies: 100% vs. 80.00%, anomalies of great vessels: 100% vs. 88.57%, separate thoracic and abdominal anomalies: 100% vs. 76.92%, respectively. Combined with TTE, DSCT can achieve excellent diagnostic performance in intracardiac anomalies (sensitivity, 91.30% vs. 100%. The mean image quality score was 3.70 ± 0.46 (κ = 0.76. The estimated mean effective dose was < 1 mSv (0.88 ± 0.34 mSv.Retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus expose the patients to a much lower radiation dose.

  4. Clinical application of dual-source computed tomography in diagnosis and treatment of tumor in the oral and maxillofacial region%双源CT在颌面部肿瘤诊疗中的临床应用

    Institute of Scientific and Technical Information of China (English)

    郭照中; 刘学; 张恒; 李焱; 王杨; 孙辉

    2012-01-01

    目的:探讨双源CT(Dual-source computed tomography,DSCT)在颌面部肿瘤诊疗中的应用价值.方法:7例颌面部肿瘤病人通过双源CT检查,将数据发送至工作站进行多平面重建、容积重建.结果,7例患者均经手术治疗,术中所见肿瘤部位与周围神经、血管、软组织及硬组织关系均与双源CT检查结果一致.结论:双源CT具有扫描速度快,图像清晰的特点,在工作站上三维影像可以任意旋转和切割,从不同角度观察肿瘤与周边血管、神经、软组织及硬组织的关系,为诊断和治疗提供了大量准确信息.%Objective: To evaluate the clinical values of the Dual-source computed tomography for diagnosis and treatment in maxillofacial tumors. Method: 7 cases of maxillofacial tumors were examined with Dual-source computed tomography and then the images were taken with multi-planar reformats and volume rendering technique on work-station. Result: All the patients have been operated. Conclusion: Dual-source CT can be provided with characteristic of ultrafast speed scan and clear images. Three-dimensional CT images were obtained from circumgyration and incision at will on work-station.Pathological changes could be observed from many projection in 3D images. Dual-source CT can offer a lot of information for constitution plan of treatment. Dual-source CT is a valuable method in diagnosis and treatment of facial fractures, and the combination of 2D-CT and 3D-CT would be the best demonstration.

  5. Dual-source computed tomography. Effect on regional and global left ventricular function assessment compared to magnetic resonance imaging; Untersuchung der regionalen und globalen linksventrikulaeren Funktion mit der Dual-Source-Computertomografie im Vergleich zur Magnetresonanztomografie

    Energy Technology Data Exchange (ETDEWEB)

    Lueders, F.; Seifarth, H.; Wessling, J.; Heindel, W.; Juergens, Kai Uwe [Inst. fuer Klinische Radiologie, Universitaetsklinikum Muenster (Germany); Fischbach, R. [Klinik fuer Radiologie, Nuklearmedizin und Neuroradiologie, Asklepios Klinik Altona (Germany)

    2009-10-15

    Purpose: to determine regional and global left ventricular (LV) functional parameters and to perform segmental wall thickness (SWT) and motion (WM) analysis of dual source CT (DSCT) with optimized temporal resolution versus MRI. Materials and Methods: 30 patients with known or suspected CAD, non-obstructive HCM, DCM, ARVCM, Fallot Tetralogy, cardiac sarcoidosis and cardiac metastasis underwent DSCT and MRI. The DSCT and MR images were evaluated: end-systolic (ESV), end-diastolic LV (EDV) volumes, stroke volume (SV), ejection fraction (EF), and myocardial mass (MM) as well as LV wall thickening and segmental WM applying the AHA model were obtained and statistically analyzed. Results: The mean LV-EDV (r = 0.96) and ESV (r = 0.98) as well as LV-EF (r = 0.97), SV (r = 0.83), and MM (r = 0.95) correlated well. Bland Altman analysis revealed little systematic underestimation of LV-EF (-1.1 {+-} 7.8%), EDV (-0.3 {+-} 18.2 ml), SV (-1.3 {+-} 16.7 ml) and little overestimation of ESV (1.1 {+-} 7.8 ml) and MM (12.8 {+-} 14.4 g) determined by DSCT. Systolic reconstruction time points correlated well (DSCT 32.2 {+-} 6.7 vs. MRI 35.6 {+-} 4.4% RR-interval). The LV wall thickness obtained by DSCT and MRI showed close correlation in all segments (diameter diff 0.42 {+-} 1 mm). In 413 segments (89%) WM abnormalities were equally rated, whereas DSCT tended to underestimate the degree of wall motion impairment. Conclusion: DSCT with optimized temporal resolution enables regional and global LV function analysis as well as segmental WM analysis in good correlation with MRI. However, the degree of WM impairment is slightly underestimated by DSCT. (orig.)

  6. Measurement of opening and closing angles of aortic valve prostheses in vivo using dual-source computed tomography: Comparison with those of manufacturers' in 10 different types

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Young Joo; Kim, Young Jin; Hong, Yoo Jin; Lee, Hye Jeong; Hur, Jin; Im, Dong Jin; Kim, Yun Jung; Choi, Byoung Wook [Dept. of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2° in seven types of valves, 11.0° in On-X valves, and 15.5° in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG.

  7. Correlation between Coronary Artery Stenosis and Plaque Nature Dual-Source Computed Tomography for Coronary Angiography%双源 CT 对冠状动脉狭窄及斑块性质的应用价值

    Institute of Scientific and Technical Information of China (English)

    柏辉; 李国晖

    2015-01-01

    目的:探讨双源CT对冠状动脉狭窄及不同性质冠状动脉斑块的诊断价值。方法:对50例临床确诊及拟诊冠心病患者行双源CT冠状动脉成像(CCTA)检查及冠状动脉造影(CCA),以CCA结果为参考标准,评估双源CT对不同性质斑块所致冠状动脉狭窄的特异度、敏感度、阳性预测值、阴性预测值及准确性,分析狭窄程度与斑块成分间的相关性。结果:与CCA对照,50例患者中,双源CT对诊断冠状动脉狭窄的特异度、敏感度、阳性预测值、阴性预测值依次如下:轻度狭窄分别为98.9%、46.7%、77.8%、95.8%;中度狭窄分别为97.6%、71.0%、84.6%、94.8%;重度狭窄分别为96.6%、96.4%、96.4%、98.6%。误诊冠状动脉狭窄共20支,诊断符合率为89.8%。对非钙化性斑块所致管腔狭窄的诊断符合率达84.3%,高于钙化性斑块(76.9%)。结论:双源CT冠状动脉成像能够有效判断冠状动脉狭窄程度及斑块成分。%Objective: To discuss the diagnosis value for coronary artery of different components of plaque and stenosis by dual-source computed tomography coronary artery imaging.Method:A total of 50 pa-tients diagnosed with coronary heart disease underwent dual-source computed tomography coronary artery ( CCTA) imaging and coronary angiography( CCA) .The specificity,sensitivity, positive predictive value,neg-ative predictive value,and accuracy for the quantitative detection of stenosis assessed.Result:In the 50 pa-tients,The specificity,sensitivity, positive predictive value,negative predictive value and accuracy for the de-tection of coronary artery stenosis assessed with dual-source CT were respectively:for<50 stenosis,98.9%, 46.7%,77.8%,95.8%;for 50 ~74 stenosis,97.6%,71.0%,84.6%,94.8%;for≥75 stenosis,96.6%、96. 4%、96.4%、98.6%.Comparing with CCA,misdiagnosis was observed in 20 of 196 arteries with dual-source CT

  8. Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Bittner, Daniel O. [University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuernberg (FAU), Department of Internal Medicine 2 (Cardiology), Erlangen (Germany); Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Boston, MA (United States); Arnold, Martin; Klinghammer, Lutz; Schuhbaeck, Annika; Hell, Michaela M.; Muschiol, Gerd; Gauss, Soeren; Achenbach, Stephan; Marwan, Mohamed [University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuernberg (FAU), Department of Internal Medicine 2 (Cardiology), Erlangen (Germany); Lell, Michael; Uder, Michael [University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuernberg (FAU), Department of Radiology, Erlangen (Germany); Hoffmann, Udo [Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Boston, MA (United States)

    2016-12-15

    Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 ± 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 ± 60 HU/1.5 at the aortic annulus compared to 289 ± 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 ± 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. (orig.)

  9. Transluminal attenuation gradient in coronary computed tomography angiography for determining stenosis severity of calcified coronary artery: a primary study with dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen; Wei, Mengqi; Wen, Didi; Zhao, Hongliang; Liu, Ying; Li, Jian [Fourth Military Medical University, Department of Radiology, Xijing Hospital, Xi' an, Shaanxi Province (China); Li, Jiayi [Fourth Military Medical University, Department of Cardiology, Xijing Hospital, Xi' an, Shaanxi Province (China)

    2015-05-01

    To evaluate the diagnostic accuracy of transluminal attenuation gradient (TAG) for stenosis severity of calcified lesions assessed by coronary computed tomography angiography (CCTA). One hundred seven patients who underwent CCTA and coronary angiography (CAG) were enrolled. TAGs of 309 major epicardial coronary arteries were measured. The impact of plaque composition, Agatston scores, and lesion length ratio on TAG were analyzed. Diagnostic performance vs. CAG of TAG, CCTA, and combined TAG/CCTA were evaluated, and incremental value of TAG for reclassification of CCTA stenosis severity in calcified lesions was also analyzed. TAG decreased consistently with stenosis severity. TAG was significantly lower in coronary arteries with calcification scores >300 and lesion length ratios >2/3. TAG improved diagnostic accuracy of CCTA (c-statistic =0.982 vs. 0.942, P = 0.0001) in calcified lesions, and the sensitivity, specificity, positive, and negative predictive values of TAG cutoff ≤ -11.33 were 72 %, 91 %, 88 %, and 78 %, respectively. The addition of TAG to CCTA resulted in significant reclassification (NRI =0.093, P = 0.022) in calcified vessels. Measurement of TAG may improve diagnostic performance and reclassification of CCTA in coronary stenosis caused by calcified lesions. (orig.)

  10. Free-breathing high-pitch 80kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose.

    Science.gov (United States)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J; Scholtz, Jan-Erik

    2017-04-01

    To investigate image quality, presence of motion artifacts and effects on radiation dose of 80kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1±4.9years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n=31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n=56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p>0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (pquality while lowering radiation exposure in free-breathing pediatric patients without sedation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Valoración global del corazón en el paciente con transplante cardiaco mediante tomografía computarizada de doble fuente Global evaluation of the heart in heart transplant recipients using dual-source computed tomography

    Directory of Open Access Journals (Sweden)

    G. Bastarrika

    2009-04-01

    Full Text Available La ecocardiografía y la coronariografía convencional son las dos técnicas empleadas en la práctica clínica para el seguimiento de los pacientes con transplante cardiaco. La coronariografía permite diagnosticar la vasculopatía del injerto, pero se trata de un procedimiento invasivo no exento de complicaciones. La tomografía computarizada multicorte convencional es una técnica no invasiva útil para descartar enfermedad coronaria y estudiar la función cardiaca. Sin embargo, debido a su resolución temporal es necesario administrar fármacos betabloqueantes por lo que su utilidad en los pacientes con escasa respuesta a esta medicación, como los transplantados cardiacos, es limitada. La TC de doble fuente permite estudiar las arterias coronarias en todos los individuos con independencia de su frecuencia cardiaca. En el caso que se presenta se demuestra, además, que puede ser una técnica útil para valorar la función y descartar la vasculopatía del injerto en los pacientes con transplante cardiaco.In routine clinical practice surveillance of heart transplant recipients is usually performed using echocardiography and conventional coronary angiography. The latter permits diagnosis and follow-up of coronary allograft vasculopathy. However, this procedure is invasive and is not free of complications. Conventional multislice computed tomography (MSCT has been shown to be a useful non-invasive tool for ruling out coronary artery disease and evaluating cardiac function. However, due to its limited temporal resolution betablocker administration is required, and its usefulness in certain patient populations with restricted response to this medication, such as heart transplant recipients, may therefore be limited. Dual-source CT (DSCT allows evaluation of the coronary arteries in all individuals independent of their heart rate. In the case presented here, we demonstrate that DSCT may be useful for evaluating cardiac function and ruling out

  12. 炫速双源CT的客观测量在诊断冠状动脉支架内再狭窄中的应用%Usefulness of flash dual-source computed tomography for evaluation of coronary artery in-stent restenosis

    Institute of Scientific and Technical Information of China (English)

    章盈; 毛萍; 王欢; 杜常青; 王亚利; 汤益民; 唐礼江

    2016-01-01

    Objective To investigate the value of flash dual- source computed tomography (CT) angiography in the evaluation of coronary artery in- stent restenosis (ISR). Methods 101 patients with 167 coronary stents underwent dual- source CT angiography for re- examination. CT values of different segments of vessels with stents were measured for evaluation of ISR and compared with the results of elective coronary angiography performed during fol owing 60 days. The accuracy and cut- off value of dual- source CT in the diagnosis of ISR were calculated. Results The CT image quality of 151 stents (90.5%) was suitable for evaluation. The diameter of stent was a main factor influencing CT image quality. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of dual- source CT for the diagnosis of ISR were 83.8%, 82.8%, 77.0%, 88.2%and 83.2%, respectively. The cutoff points of a difference in CT value from aortic root to the vessel 5~10mm proximal to the stent, proximal end of the stent, in- stent lumen, distal end of the stent, and the vessel 5~10mm distal to the stent for diagnosing ISR were 7.5Hu, 16.0Hu, 42.5Hu, 47.5Hu and 56.0Hu, respectively. Conclusion The in- stent lumen of coronary artery can be imaged clearly by dual- source CT, which could provide higher diagnostic accuracy of ISR.%目的:探讨炫速双源CT在诊断冠状动脉支架内再狭窄(ISR)中的应用。方法对101例患者植入的167枚冠脉支架行炫速双源CT血管显像复查,测量支架段各部位的CT值评价支架内再狭窄,并与随后60d内所做的选择性冠状动脉造影结果对比,计算炫速双源CT诊断ISR的准确程度及诊断ISR的CT临界值。结果炫速双源CT显示151枚(90.5%)支架的影像质量适于诊断,支架直径是主要影响因素。炫速双源CT评价冠状动脉ISR的敏感度、特异度、阳性预测值、阴性预测值和符合率分别为83.8%、82.8%、77.0%、88.2%和83.2%。诊断ISR

  13. 双源CT与冠状动脉造影评估冠状动脉支架内再狭窄%Dual-Source Computed Tomography and Coronary Angiography in Evaluation of In-Stent Restenosis

    Institute of Scientific and Technical Information of China (English)

    王联发; 纪勤炯; 朱有志; 侯勇; 黄猛珣; 顾磊

    2012-01-01

    目的 对比分析双源CT( dual-source CT,DSCT)与冠状动脉造影(coronary angiography,CAG)评估支架内再狭窄( in stent restenosis,ISR)的结果,探讨支架所在部位及支架大小对DSCT评估冠状动脉ISR的影响.方法 106例同期行DSCT及SCAG检查的支架术后的患者,以SCAG结果为标准,比较DSCT评估不同部位及大小支架ISR的敏感性、特异性及准确性.结果 173枚支架中有156枚支架DSCT显影良好.DSCT显示有ISR的支架33枚,CAG证实存在ISR的支架38枚,DSCT诊断ISR的敏感度和特异度分别为78.9%和97.5%,阳性预测值90.9%,阴性预测值93.5%,一致率为92.9%.DSCT对近心端支架再狭窄的检出率优于远心端支架;直径≥3.0 mm支架的ISR检出率优于直径<3.0mm支架.结论 支架内径大小及所在部位影响DSCT图像的显示.DSCT在评估ISR方面,可基本取代SCAG作为冠脉近端支架及大直径支架(支架直径≥3 mm)通畅情况的评估方式.%Objective To compare the results of dual-source CT(DSCT) and coronary angiography (CAG) in the diagnosis of in-stent restenosis ( ISR) , and discuss the influence of the positions and size of stents on the evaluation results of ISR by DSCT. Methods The 106 patients in the same period underwent DSCT and CAG were included in the study, analysis and comparison ISR of DSCT diagnostic sensitivity, specificity and accuracy to detect in-stent restenosis was evaluated referring to coronary angiography. ISR was defined as a lesion demonstrating stenosis greater than 50%. Results In all 173 stents, 156 stents could be assessed by DSCT. 33 stents could be detected ISR by DSCT.38 stents with ISR indicated by CAG. The sensitivity,specificity,positive and negative predictive value and accuracy to identify ISR was 78.9% ,97.5% ,90.9% and 93.5% ,92.9% .respectively. DSCT coronary artery proximal in-stent restenosis detection rate were superior to the distal stent. The detection with DSCT in-stent restenosis of positive

  14. Cardiac amyloidosis imaged by dual-source computed tomography.

    Science.gov (United States)

    Marwan, Mohamed; Pflederer, Tobias; Ropers, Dieter; Schmid, Michael; Wasmeier, Gerald; Söder, Stephan; Daniel, Werner G; Achenbach, Stephan

    2008-11-01

    The ability of contrast-enhanced CT to detect "late enhancement" in a fashion similar to magnetic resonance imaging has been reported previously. Typical myocardial distribution patterns of "late enhancement" have been described for MRI. The same patterns can be observed in CT imaging, albeit at a lower signal to noise ratio. We report a case of cardiac amyloidosis with a typical pattern of subendocardial, circumferential late enhancement in all four cardiac chambers.

  15. Dual-source Dual-energy Computed Tomography Imaging of Acute Necrotizing Pancreatitis——Priliminary Study%双源CT双能量扫描对急性坏死性胰腺炎影像诊断价值的初步探讨

    Institute of Scientific and Technical Information of China (English)

    袁元; 黄子星; 李真林; 宋彬; 邓莉萍

    2011-01-01

    目的 初步探讨双源CT双能量技术扫描对急性坏死性胰腺炎影像诊断的价值.方法 回顾性分析32例确诊急性坏死性胰腺炎患者的双源CT双能量门静脉期增强图像,测量、计算并评估80 kV、140 kV和加权融合120kV图像中的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比以及图像主观诊断评分.结果 80 kV、140 kV和加权融合120 kV图像中胰腺实质-坏死灶CT差值分别为(67.22±21.11)HU、(42.91±15.12)HU、(48.78±16.13)HU;胰腺实质-坏死灶对比噪声比分别为8.35±3.63、5.89±2.67、7.72±3.58;图像主观诊断评分分别为3.87±0.34、3.28±0.81、3.56±0.67.3组图像中的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比以及图像主观诊断评分之间差异均有统计学意义(P<0.05).其中80 kV图像的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比和图像主观诊断评分均高于140 kV和加权融合120 kV图像.结论 急性坏死性胰腺炎患者双源CT双能量门静脉期增强扫描,80 kV图像对坏死灶的显示优于140 kV和加权融合120 kV图像.%Objective To investigate the clinical value of dual-source computed tomography dual-energy technology in the imaging diagnosis of acute necrotizing pancreatitis. Methods Thirty-two cases with diagnosed acute necrotizing pancreatitis and underwent contrast-enhanced dual-source dual-energy CT in portal venous phase were retrospectively analyzed. Difference of CT value between pancreatic parenchyma and necrosis, contrast to noise ratio of pancreatic parenchyma-to-necrosis and score of subjective diagnosis were measured, calculated and assessed on CT images of 80 kV, 140 kV and weighted-average 120 kV. Results The difference of CT value between pancreatic parenchyma and necrosis in the images of 80 kV, 140 kV and weighted-average 120 kV was (67. 22± 21. 11) HU, (42. 91 ±15. 12) HU, (48. 78 ±16. 13) HU; contrast to noise ratio of

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special ... the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT ...

  17. Dual-source computed tomographic coronary angiography: image quality and stenosis diagnosis in patients with high heart rates.

    Science.gov (United States)

    Zheng, Minwen; Li, Jiayi; Xu, Jian; Chen, Kang; Zhao, Hongliang; Huan, Yi

    2009-01-01

    We sought to evaluate prospectively the effects of heart rate and heart-rate variability on dual-source computed tomographic coronary image quality in patients whose heart rates were high, and to determine retrospectively the accuracy of dual-source computed tomographic diagnosis of coronary artery stenosis in the same patients.We compared image quality and diagnostic accuracy in 40 patients whose heart rates exceeded 70 beats/min with the same data in 40 patients whose heart rates were 70 beats/min or slower. In both groups, we analyzed 1,133 coronary arterial segments. Five hundred forty-five segments (97.7%) in low-heart-rate patients and 539 segments (93.7%) in high-heart-rate patients were of diagnostic image quality. We considered P coronary artery, nor were any significant differences found between the groups in the accurate diagnosis of angiographically significant stenosis.Calcification was the chief factor that affected diagnostic accuracy. In high-heart-rate patients, heart-rate variability was significantly related to the diagnostic image quality of all segments (P = 0.001) and of the left circumflex coronary artery (P = 0.016). Heart-rate variability of more than 5 beats/min most strongly contributed to an inability to evaluate segments in both groups. When heart rates rose, the optimal reconstruction window shifted from diastole to systole.The image quality of dual-source computed tomographic coronary angiography at high heart rates enables sufficient diagnosis of stenosis, although variability of heart rates significantly deteriorates image quality.

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  1. Application of flash dual-source computed tomography angiography in free heart rate triple-rule-out chest pain examination%炫速双源CT在自由心率胸痛三联成像中的应用价值

    Institute of Scientific and Technical Information of China (English)

    陈洪亮; 邱丽华; 刁显明; 张君海; 袁梦华; 敖永胜; 陈丽

    2016-01-01

    目的 探讨炫速双源CT在自由心率胸痛三联成像中的图像质量和临床价值.方法 2014年5月至2015年4月胸痛患者行炫速双源CT扫描整个胸部,同时行冠状动脉数字减影血管造影(DSA)检查,共104例.采用多种重组方式显示冠状动脉、肺动脉、主动脉,评价成像质量和能否满足临床诊断需要,并对冠状动脉狭窄情况与DSA进行对比.结果 扫描时间为(7.3±1.9)s.升主动脉CT值为(440.5±84.3)Hu;肺动脉平均CT值为(344.5±88.8)Hu,主动脉和肺动脉图像质量全部为优.全组1352段冠状动脉质量基本能满足诊断,其中优89.5%,良10.3%,差0.2%.共15段管腔重度狭窄(其中3段闭塞),27段管腔中度狭窄,43段管腔轻度狭窄,与DSA比较差异无统计学意义(P>0.05).结论 炫速双源CT扫描速度快,时间分辨率高,自由心率胸主动脉、肺动脉和冠状动脉成像图像质量好,对胸痛三联症的及时准确诊断具有较大的临床意义.%Objective To evaluate the imaging quality and clinical value of the flash dual-source CT in the free heart rate triple-rule-out chest pain examination. Methods From May 2015 to April 2015, a total of 104 patients with chest pain underwent both flash dual-source CT to scan the entire chest and digital subtraction angiography (DSA) to ex-amine coronary artery. Various combination methods were utilized to image aorta, pulmonary artery and coronary ar-tery for evaluating whether the flash dual-source CT imaging quality to meet the needs of clinical diagnosis. The flash dual-source CT image of coronary stenosis also was compared with DSA. Results With scanning time of (7.3 ± 1.9) s, the ascending aorta CT value of (440.5±84.3) Hu, pulmonary average CT value of (344.5±88.8) Hu, the aorta and pul-monary artery image quality is both excellent. Full set of 1352 segments of coronary artery qualities can meet the needs of clinical diagnosis with excellent 89.5%, good 10.3%and only 0.2%poor. Compared with DSA

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  3. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  11. 双源CT的临床应用进展%Development and Clinical Application of Dual-Source CT

    Institute of Scientific and Technical Information of China (English)

    徐辉; 殷信道; 吴旻

    2014-01-01

    In 2005 and 2008, Siemens launched the 昀rst and second generation Dual Source CT system. This paper reviews the basic structure, characteristics, advantages and application of Dual Source CT system.%2005年、2008年西门子相继推出第一代双源CT Definition(Dual Source Computed Tomography, DSCT)、第二代双源CT(SOMATOM De昀nition Flash),本文主要就双源CT的基本结构、特点、优势以及在临床应用方面的进展作一综述。

  12. Noise-tolerance analysis for detection and reconstruction of absorbing inhomogeneities with diffuse optical tomography using single- and phase-correlated dual-source schemes

    Science.gov (United States)

    Kanmani, B.; Vasu, R. M.

    2007-03-01

    An iterative reconstruction procedure is used to invert intensity data from both single- and phase-correlated dual-source illuminations for absorption inhomogeneities. The Jacobian for the dual source is constructed by an algebraic addition of the Jacobians estimated for the two sources separately. By numerical simulations, it is shown that the dual-source scheme performs superior to the single-source system in regard to (i) noise tolerance in data and (ii) ability to reconstruct smaller and lower contrast objects. The quality of reconstructions from single-source data, as indicated by mean-square error at convergence, is markedly poorer compared to their dual-source counterpart, when noise in data was in excess of 2%. With fixed contrast and decreasing inhomogeneity diameter, our simulations showed that, for diameters below 7 mm, the dual-source scheme has a higher percentage contrast recovery compared to the single-source scheme. Similarly, the dual-source scheme reconstructs to a higher percentage contrast recovery from lower contrast inhomogeneity, in comparison to the single-source scheme.

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ... stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and skull or ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ... the best imaging modality for sinusitis. Tell your doctor if there’s a possibility you are pregnant and ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... for a recovery period and will be given instructions on any limitations in activity for the day. ... Images related to Children's (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) CT (Computed Tomography) Sponsored ...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography ( ... more commonly known as a CT or CAT scan, is a diagnostic medical test that, like traditional ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless ... table. Other imaging methods such as ultrasound or magnetic resonance (MR) imaging can provide pictures of certain areas ...

  2. Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Karcaaltincaba, M.; Karaosmanoglu, D.; Akata, D.; Sentuerk, S.; Oezmen, M. [Dept. of Radiology, Hacettepe Univ. School of Medicine (Turkey); Alibek, S. [Dept. of Radiology, Hacettepe Univ. School of Medicine (Turkey); Radiology Inst., Univ. of Erlangen (Germany)

    2009-09-15

    Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement when compared to prone CT images. The major advantage of DE colonoscopy was the lack of misregistration. Conclusion: DE MDCT colonoscopy is technically feasible and may obviate the need for unenhanced prone images. It may be possible to perform noncathartic DECT colonoscopy. The major limitation is the limited FOV of tube B. The dose should be optimized to reduce streak artifacts in the pelvic region. (orig.)

  3. Proton computed tomography

    Science.gov (United States)

    Bucciantonio, Martina; Sauli, Fabio

    2015-05-01

    Proton computed tomography (pCT) is a diagnostic method capable of in situ imaging the three-dimensional density distribution in a patient before irradiation with charged particle beams. Proposed long time ago, this technology has been developed by several groups, and may become an essential tool for advanced quality assessment in hadrontherapy. We describe the basic principles of the method, its performance and limitations as well as provide a summary of experimental systems and of results achieved.

  4. Computer processing of tomography data

    OpenAIRE

    Konečný, Jan

    2011-01-01

    Computer processing of tomography data Tomographs are one of the most important diagnostic devices, which are used in every hospital nowadays; they have already been so for a considerable period of time. The different types of tomographs and the processing of tomographic data and imaging of these data are the subject of this thesis. I have described the four most common types of tomography: X-ray Computed Tomography, Magnetic Resonance Imaging, Positron Emission Tomography and Single Photon E...

  5. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  6. Abdominal perfusion computed tomography.

    Science.gov (United States)

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  7. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    Clinical trials for the treatment of cystic fibrosis (CF) lung disease are important to test and optimize new therapeutic interventions. To evaluate the effect of these interventions, sensitive and accurate outcome measures are needed. The most commonly used endpoints are spirometric variables...... are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  8. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  9. Metrizamide computed tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, T.; Tamakawa, Y.; Arii, H. (Akita Univ. (Japan). Faculty of Medicine); Takahashi, M.; Hirota, K.

    1981-11-01

    Serial computed tomography of the cervical cord was performed following metrizamide myelography in five cases of clinically suspected syringomyelia. The syrinx filled with refluxed metrizamide was demonstrated in all of the cases. The reflux of metrizamide into the syrinx was most marked several hours following intrathecal injection of metrizamide. Computed tomography combined with metrizamide myelography is essential in the diagnosis of communicating syringomyelia.

  10. REVIEW: X-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2006-07-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

  11. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  17. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  2. Systematic review of the accuracy of dual-source cardiacct for detection of arterial stenosis in difficult to image patient groups

    NARCIS (Netherlands)

    M. Westwood (Marie); H. Raatz (Heike); K. Misso (Kate); L.T. Burgers (Laura); W.K. Redekop (Ken); S.K. Lhachimi (Stefan); N. Armstrong (Nigel); J. Kleijnen (Jos)

    2013-01-01

    textabstractPurpose: To assess the diagnostic performance of dual-source cardiac (DSC) computed tomography (CT) newer-generation CT instruments for identifying anatomically significant coronary artery disease (CAD) in patients who are difficult to image by using 64-section CT. Materials and Methods:

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  11. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  12. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  13. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  14. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...... contains a survey of application examples from the manufacturing industry as well as from other industries, e.g., electrical and electronic devices, inhomogeneous materials, and from the food industry. Challenges as well as major national and international coordinated activities in the field of industrial...

  15. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    Modern diagnostic imagining techniques are gaining popularity in forensic medicine. Denmark has been involved in the development of this use of imaging techniques from the beginning. The Institute of Forensic Medicine at the University of Southern Denmark acquired a helical computed tomography (CT...... AND METHODS: This thesis investigated 900 forensic cases that were CT-scanned and autopsied at the Institute of Forensic Medicine, University of Southern Denmark, from 2006-2011. The scanner was a Siemens Somatom Spirit dual-slice CT-scanner with a Siemens Syngo MultiModality workstation. Contrast enhancement...

  16. Future of cardiac computed tomography

    Institute of Scientific and Technical Information of China (English)

    Carlo N De Cecco; U Joseph Schoepf

    2015-01-01

    Coronary computed tomography angiography(CCTA)has become an integral tool in the noninvasive diagnostic workup of patients with suspected coronary artery disease in both elective and emergency settings. Today, it represents a mature technique providing accurate, non-invasive morphological assessment of the coronary arteries and atherosclerotic plaque burden. Iterative reconstruction algorithms, low kV imaging, and single-heart beat acquisitions hold promise to further reduce dose requirements and improve the safety and robustness of the technique in several circumstances including imaging of heavily calcified vessels, patients with morbid obesity or irregular heart rates, and assessment in the emergency setting. However, it has become clear over recent years that cardiac radiologists need to take further steps towards the development and integration of functional imaging with morphological CCTA assessment to truly provide a comprehensive evaluation of the heart. Computed tomography myocardial perfusion imaging, including both dynamic and static dual-energy approaches, has demonstrated the ability to directly assess and quantify myocardial ischemia with simultaneous CCTA acquisition with a reasonable contrast medium volume and radiation dose delivered to the patient. In order to promote CCTA in the clinical and research environments, radiologists should prepare to embrace the change from morphological to functional imaging, furnishing all the necessary resources and information to referring clinicians.

  17. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...

  18. Computed tomography of the gallbladder.

    Science.gov (United States)

    Havrilla, T R; Reich, N E; Haaga, J R; Seidelmann, F E; Cooperman, A M; Alfidi, R J

    1978-06-01

    Computed tomography (CT) was used to study 79 patients with suspected gallbladder disease. First and second generation scanners were used to determine the efficacy of CT in detecting cholecystitis or cholelithiasis. Manifestations of gallbladder disease such as hydrops, opaque and nonopaque gallstones, chronic cholecystitis with thickened inflammatory walls, and secondary liver abscesses can be easily detected. It is a useful technique for individuals in whom the gallbladder has failed to opacity on oral cholecystography. The scanning method is described, and estimates of reliability are given including its accuracy, limitations, and place in the management of gallbladder disease, especially cholelithiasis. When conventional radiographic examinations or ultrasound fail to give definitive diagnostic information, CT can be a useful alternative with an overall diagnostic accuracy greater than 80%.

  19. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  20. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  1. Computed tomography of cryogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-08-30

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions.

  2. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19, ... The ECG is also needed to help the computer that is connected to the CT scanner create ...

  3. RADIATION DOSE IN PAEDIATRIC COMPUTED TOMOGRAPHY ...

    African Journals Online (AJOL)

    Computed tomography (CT) is a powerful tool for the accurate ... increasing, and estimates suggest that quantitative lifetime ... Keywords: Computed Tomography, Radiation Risk, Radiation Dose, Patient Dose ... techniques, such as MRI and ultrasound, which do not ..... in the course of management are not monitored to.

  4. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils.

  5. Soft tissue discrimination ex vivo by dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Zachrisson, H., E-mail: helene.zachrisson@lio.s [Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Clinical Physiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Engstroem, E. [Clinical Physiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Engvall, J.; Wigstroem, L. [Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Clinical Physiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Smedby, O.; Persson, A. [Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Radiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden)

    2010-08-15

    Purpose: Dual Energy Computed Tomography (DECT) may provide additional information about the chemical composition of tissues compared to examination with a single X-ray energy. The aim of this in vitro study was to test whether combining two energies may significantly improve the detection of soft tissue components commonly present in arterial plaques. Methods: Tissue samples of myocardial and psoas muscle, venous and arterial thrombus as well as fat from different locations were scanned using a SOMATOM Definition Dual Source CT system (Siemens AG, Medical Solutions, Forchheim, Germany) with simultaneous tube voltages of 140 and 80 kV. The attenuation (Hounsfield units, HU) at 80 and 140 kV was measured in representative regions of interest, and the association between measured HU values and tissue types was tested with logistic regression. Results: The combination of two energy levels (80 and 140 kV) significantly improved (p < 0.001) the ability to correctly classify venous thrombus vs arterial thrombus, myocardium or psoas; arterial thrombus vs myocardium or psoas; myocardium vs psoas; as well as the differentiation between fat tissue from various locations. Single energy alone was sufficient for distinguishing fat from other tissues. Conclusion: DECT offers significantly improved in vitro differentiation between soft tissues occurring in plaques. If this corresponds to better tissue discrimination in vivo needs to be clarified in future studies.

  6. Computed tomography of arachnoid cyst

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Min Gi; Bae, Weon Tae; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyun De [College of Medicine, Chonnam National University, Kwangju (Korea, Republic of)

    1988-02-15

    The preoperative diagnosis of intracranial arachnoid cysts has been simplified, and made more rapid and accurate with computed tomography (CT). Using CT cisternography, detailed anatomic and physiologic information of arachnoid cysts could be obtained. CT features of pathologically proven 21 arachnoid cysts that were examined at Chonnam National University Hospital from June 1983 to May 1987 were analyzed. The results were as follows: 1.Prevalent age group was the 1st decade (8 cases) and male to female ratio was 17:4. 2.Clinical features were related to the location of arachnoid cyst, common symptoms were headache (53.3%), convulsion, mental change and walking disturbance. 3.Location of the arachnoid cyst were in supratentorial region (15 cases) most in middle cranial fossa (12 cases), and infratentorial region (6 cases), common at the retrocerebellar cisternal space (3 cases). 4.Shapes of arachnoid cyst were biconvex with straight inner margin (8 cases), spherical (7 cases), simple biconvex (3 cases) and others (3 cases). 5.Size of the arachnoid cyst, in the greatest dimension, was ranged from 2cm to 9cm and commonly distributed between 3cm to 5cm (14 cases). 6.Of all 14 cases, who did CT cisternography using metrizamide (11 cases) and iopamidol (3 cases), 2 cases had communication with the subarachnoid space.

  7. A Freeware Path to Neutron Computed Tomography

    Science.gov (United States)

    Schillinger, Burkhard; Craft, Aaron E.

    Neutron computed tomography has become a routine method at many neutron sources due to the availability of digital detection systems, powerful computers and advanced software. The commercial packages Octopus by Inside Matters and VGStudio by Volume Graphics have been established as a quasi-standard for high-end computed tomography. However, these packages require a stiff investment and are available to the users only on-site at the imaging facility to do their data processing. There is a demand from users to have image processing software at home to do further data processing; in addition, neutron computed tomography is now being introduced even at smaller and older reactors. Operators need to show a first working tomography setup before they can obtain a budget to build an advanced tomography system. Several packages are available on the web for free; however, these have been developed for X-rays or synchrotron radiation and are not immediately useable for neutron computed tomography. Three reconstruction packages and three 3D-viewers have been identified and used even for Gigabyte datasets. This paper is not a scientific publication in the classic sense, but is intended as a review to provide searchable help to make the described packages usable for the tomography community. It presents the necessary additional preprocessing in ImageJ, some workarounds for bugs in the software, and undocumented or badly documented parameters that need to be adapted for neutron computed tomography. The result is a slightly complicated, but surprisingly high-quality path to neutron computed tomography images in 3D, but not a replacement for the even more powerful commercial software mentioned above.

  8. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  9. Iterative Reconstruction for Cardiopulmonary Computed Tomography

    NARCIS (Netherlands)

    Willemink, M.J.

    2015-01-01

    Introduction The number of computed tomography (CT) examinations has increased rapidly since CT became commercially available. This resulted in growing concerns regarding the risk of malignancies induced by application of medical ionizing radiation. Therefore, radiation dose reduction strategies ar

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... materials and a metallic taste in his/her mouth that lasts for a few minutes. Occasionally, a ...

  11. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    Mcevoy, Fintan J; Buelund, Lene; Strathe, Anders B

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  12. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  13. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  14. Single photon emission computed tomography/computed tomography of the skull in malignant otitis externa.

    Science.gov (United States)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Kamaleshwaran, Koramadai Karuppusamy; Agrawal, Kanhaiyalal; Gupta, Ashok Kumar; Mittal, Bhagwant Rai

    2012-01-01

    Malignant otitis externa is a severe, rare infective condition of the external auditory canal and skull base. The diagnosis is generally made from a range of clinical, laboratory, and imaging findings. Technetium 99m methylene diphosphonate bone scintigraphy is known to detect osteomyelitis earlier than computed tomography. The authors present a patient with bilateral malignant otitis externa where the extent of skull base involvement was determined on 3-phase bone scintigraphy with single photon emission computed tomography/computed tomography.

  15. Computed tomographic angiography or conventional coronary angiography in therapeutic decision-making

    NARCIS (Netherlands)

    Piers, Lieuwe H.; Dikkers, Riksta; Willems, Tineke P.; de Smet, Bart J. G. L.; Oudkerk, Matthijs; Zijlstra, Felix; Tio, Rene A.

    2008-01-01

    To evaluate non-invasive angiography using dual-source computed tomography (CT) for the determination of the most appropriate therapeutic strategy in patients with suspected coronary artery disease (CAD). CT angiography (Dual Source CT, Somatom Definition, Siemens Medical Systems, Forchheim, Germany

  16. Coronary fly-through or virtual angioscopy using dual-source MDCT data.

    Science.gov (United States)

    van Ooijen, Peter M A; de Jonge, Gonda; Oudkerk, Matthijs

    2007-11-01

    Coronary fly-through or virtual angioscopy (VA) has been studied ever since its invention in 2000. However, application was limited because it requires an optimal computed tomography (CT) scan and time-consuming post-processing. Recent advances in post-processing software facilitate easy construction of VA, but until now image quality was insufficient in most patients. The introduction of dual-source multidetector CT (MDCT) could enable VA in all patients. Twenty patients were scanned using a dual-source MDCT (Definition, Siemens, Forchheim, Germany) using a standard coronary artery protocol. Post-processing was performed on an Aquarius Workstation (TeraRecon, San Mateo, Calif.). Length travelled per major branch was recorded in millimetres, together with the time required in minutes. VA could be performed in every patient for each of the major coronary arteries. The mean (range) length of the automated fly-through was 80 (32-107) mm for the left anterior descending (LAD), 75 (21-116) mm for the left circumflex artery (LCx), and 109 (21-190) mm for the right coronary artery (RCA). Calcifications and stenoses were visualised, as well as most side branches. The mean time required was 3 min for LAD, 2.5 min for LCx, and 2 min for the RCA. Dual-source MDCT allows for high quality visualisation of the coronary arteries in every patient because scanning with this machine is independent of the heart rate. This is clearly shown by the successful VA in all patients. Potential clinical value of VA should be determined in the near future.

  17. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  18. Prevalence of coronary artery ectasia in older adults and the relationship with epicardial fat volume by cardiac computed tomography angiography

    Institute of Scientific and Technical Information of China (English)

    Jun-Jie Yang; Xia Yang; Zhi-Ye Chen; Qi Wang; Bai He; Luo-Shan Du; Yun-Dai Chen

    2013-01-01

    Objective Coronary artery ectasia (CAE) refers to abnormal dilation of coronary artery segments to 1.5 times of adjacent normal ones. Epicardial fat is associated with cardiovascular risk factors. The relationship between CAE and epicardial fat has not yet been investigated. This study aimed to assess the relationship between CAE and epicardial fat volume (EFV) in older people by dual-source computed tomography coronary angiography (CTCA). Methods We prospectively enrolled 1400 older adults who were scheduled for dual-source CTCA. Under reconstruction protocols, patients with abnormal segments 1.5 times larger than the adjacent segments were accepted as CAE. EFV was measured by semi-automated software. Traditional risk factors in CAE patients, as well as the extent of EFV, were analyzed and compared to non-CAE group. Results A total of 885 male and 515 female older patients were enrolled. CAE was identified by univariable analysis in 131 patients and significantly correlated to hypertension, smoking, hyperlipidemia, prior percutaneous coronary intervention and ascending aorta aneurysm. EFV was shown to be significantly higher in CAE patients than patients without ectasia. In multivariable analyses, EFV (P = 0.018), hypertension (P < 0.001) and hyperlipidemia (P < 0.001) were significantly correlated to CAE. There was a significant negative correlation between EFV and Markis classification. Conclusions CAE can be reliably recognized by dual-source CTCA. Epicardial fat might play a role in etiopathogenesis and progression of CAE, providing a new target for treating ectasia.

  19. Diagnostic value of dual-source CT in Kawasaki disease

    Institute of Scientific and Technical Information of China (English)

    CHAO Bao-ting; WANG Xi-ming; WU Le-bin; CHEN Jie; CHENG Zhao-ping; WU Da-wei; DUAN Yan-hua

    2010-01-01

    Background Doppler color echocardiography is a common method for detecting coronary artery lesions in patients with Kawasaki disease(KD).However,the diagnostic accuracy for the whole coronary artery lesions is limited.The purpose of this study was to compare the diagnostic value of dual-source computed tomography (DSCT) and Doppler color echocardiography for the assessment of coronary artery lesions caused by KD.Methods Sixteen patients,12 with typical KD and 4 with atypical KD,underwent DSCT and Doppler color echocardiography.The position and internal diameter of each coronary artery lesion was measured.Correlation analysis was used to compare the diagnostic value of the two imaging modalities.Results ln the typical KD group, seven patients did not have any coronary artery Iesion as confirmed by both DSCT scans and Doppler color echocardiography;in four patients proximal coronary artery injuries were identified by both modalities;in one patient an aneurysm in the middle and distal segments of the coronary artery was detected by DSCT but was negative in Doppler color echocardiography.In the atypical KD group,three cases showed the same results with both modalities,while one case with coronary artery stenosis in the middle segment was identified by DSCT but not detected by Doppler color echocardiography.There was a good correlation between the two imaging modalities(Kappa value,0.768(≥0.75)).Conclusion DSCT coronary artery angiography is an accurate,non-invasive,and valuable technique for detecting and following up coronary artery lesions in patients with KD.

  20. Proton computed tomography images with algebraic reconstruction

    Science.gov (United States)

    Bruzzi, M.; Civinini, C.; Scaringella, M.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Presti, D. Lo; Maccioni, G.; Pallotta, S.; Randazzo, N.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.

    2017-02-01

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to 1% and spatial resolutions CT in hadron-therapy.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  3. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E; Haase, Robert; Laule, Michael

    2017-01-01

    OBJECTIVES: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninva...... angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low...

  4. Evaluation of the modulation transfer function for computer tomography by using American Association Physics Medicine Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [Dept. of Medical Science, Soonchunhyang University, Asan (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Son, Soon Yong [Dept. of Radiological Technology, Wonkwang Health Science University, Iksan (Korea, Republic of); Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, Shingu University, Sungnam (Korea, Republic of)

    2016-06-15

    In clinical computed tomography (CT), regular quality assurance (QA) has been required. This study is to evaluate the MTF for analyzing the spatial resolution using AAPM phantom in CT exam. The dual source somatom definition flash (siemens healthcare, forchheim, Germany), the brilliance 64 (philips medical system Netherlands) and aquilion 64 (toshiba medical system, Japan) were used in this study. The quantitative evaluation was performed using the image J (wayne rasband national institutes of health, USA) and chart method which is measurement of modulation transfer function (MTF). In MTF evaluation, the spatial frequencies corresponding to the 50% MTF for the CT systems were 0.58, 0.28, and 0.59 mm-1, respectively and the 10% MTF for the CT systems were 1.63, 0.89, and 1.21 mm-1, respectively. This study could evaluate the characteristic of spatial resolution of MTF using chart method, suggesting the quantitative evaluation method using the data.

  5. Dual-energy lung perfusion computed tomography: a novel pulmonary functional imaging method.

    Science.gov (United States)

    Thieme, Sven F; Johnson, Thorsten R C; Reiser, Maximilian F; Nikolaou, Konstantin

    2010-08-01

    Dual-energy computed tomography (DECT) can be used for visualization of pulmonary microvascular contrast material distribution, representing regional perfusion. It is performed as DECT angiography and allows for the reconstruction of morphologic images as well as of "perfusion maps." The authors of previous studies have shown its potential to reliably depict perfusion defects, mainly in the context of pulmonary embolism. Also in the diagnostic work-up of other pulmonary diseases, there might be additional functional information provided by dual-energy acquisition techniques. This review focuses on the physical and technical background and the potential clinical value of pulmonary DECT. Technical improvements of a second-generation dual-source CT system are elucidated.

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... of the machine, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  10. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, CHU Grenoble (France)

    2000-02-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  11. Cervical diplomyelia revealed by computed tomography (CT)

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, G.B.; Davidovits, P.; Cerisoli, M.; Giulioni, M.

    1982-05-01

    An unusual case of cervical diplomyelia diagnosed by Computed Tomography (CT) is reported. The usefulness of CT examination in the evaluation of spinal dysraphic defects is emphasized, though performed without CSF enhancement. Visualisation of spinal cord splitting in the absence of bony spicula allows the authors to differentiate between diplomyelia and diastematomyelia which have been often described by using both terms interchangeably.

  12. Computed tomography demonstration of cholecystogastric fistula

    Directory of Open Access Journals (Sweden)

    Chung Kuao Chou, MD, MPH

    2016-06-01

    Full Text Available Cholecystogastric fistula is a rare complication of chronic cholecystitis or long-standing cholelithiasis. It results from the gradual erosion of the approximated, chronically inflamed wall of the gall bladder and stomach with fistulous tract formation. The present case describes the direct visualization of a cholecystogastric fistula by computed tomography in a patient without prior biliary system complaints.

  13. Computed tomography in untreated congenital adrenal hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Harinarayana, C.V.; Renu, G.; Ammini, A.C.; Khurana, M.L.; Ved, P.; Karmarkar, M.G.; Ahuja, M.M.S.; Berry, M. (AIIMS, New Delhi (India))

    1991-02-01

    Six children with untreated congenital adrenal hyperplasia (CAH) were examined by computed tomography (CT). Three cases demonstrated diffuse enlargement of both adrenal glands with preservation of normal configuration and two showed tumorous transformation in one of the enlarged glands. One had equivocal in this group (age 2 years) also showed bilateral hyperplasia. (orig.).

  14. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  15. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  16. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  17. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  18. Computed tomography of tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto (Kobe Univ. (Japan). School of Medicine)

    1982-12-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis.

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  1. Single photon emission computed tomography/computed tomography for malignant otitis externa: lesion not shown on planar image.

    Science.gov (United States)

    Chen, Yu-Hung; Hsieh, Hung-Jen

    2013-01-01

    Malignant otitis externa is a severe and rare infection of the external acoustic meatus. Triphasic bone and (67)Ga scintigraphies are used to initial detect and follow-up the response of therapy. With single photon emission computed tomography/computed tomography images, the diagnostic sensitivity is higher. We presented a case with malignant otitis externa with initial negative planar scintigraphic finding. The lesion was detected by photon emission computed tomography/computed tomography images. We concluded that the photon emission computed tomography/computed tomography should be performed routinely for patients with suspected malignant otitis externa, even without evidence of lesion on planar images.

  2. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  3. Computed tomography of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Haughton, V.M.; Williams, A.L.

    1982-01-01

    The book describes the computed tomographic (CT) techniques for imaging the different elements comprising the spinal column and canal. The use of intravenous and intrathecal contrast enhancement and of xenon enhancement is briefly mentioned. Reconstruction techniques and special problems regarding CT of the spine are presented. CT of the spinal cord, meninges and subarachnoid space, epidural space, intervertebral discs, facet joints, and vertebrae present normal anatomy, and several common pathologic conditions. (KRM)

  4. Computed tomography in mitochondrial cytopathy

    Energy Technology Data Exchange (ETDEWEB)

    Egger, J.; Kendall, B.E.

    1981-10-01

    The clinical and computed tomographic (CT) findings in 11 proven cases of mitochondrial cytopathy (mitochondrial myopathy, Kearns Sayre syndrome, ophthalmoplegia plus) were studied. The CT changes included focal low density lesions in the basal ganglia and white matter and atrophy which could be slight or diffuse and severe. Calcification has been described in the basal ganglia, but did not occur in our series. Serial CT showed progression of the abnormalities. The differential diagnosis is discussed.

  5. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  6. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  7. Trip report: Marshall Space Center computed tomography

    Science.gov (United States)

    Harbour, J. R.; Andrews, M. K.

    BIR Inc. is a small company out of the Chicago area which sells equipment for producing images by tomography. They have built a relatively large instrument, called ACTIS, for NASA at the Marshall Space Center in Huntsville, Alabama and still gave access to this instrument. BIR has a grant from the Department of Energy (DOE) to determine the utility of computed tomography (CT) for characterization of nuclear and hazardous waste within the DOE complex. As part of this effort, the potential of this technique for obtaining images of canistered waste forms has been investigated. Funding for data acquisition was provided through this grant.

  8. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  9. Computed tomography of bones and joints.

    Science.gov (United States)

    Bruna, J; Sehr, A

    1989-01-01

    The monograph sums up the problem of CT diagnosis of bones and joints making use of predominantly the authors' own experience based on CT tests of more than 45,000 patients examined at the Department of Radiology, Charles University Medical Faculty of Hygiene teaching hospital in Prague in the years 1980-1988. Specific scans of the skeleton were made in 4,500 patients, mostly for suspicion or closer assessment of neoplasms (43.5%), the radicular lumbosacral syndrome (34.5%), and injuries (12%). The opening chapters sum up basic facts about the principle of computed tomography, the apparatus in use, the evaluation of CT images, CT radiation doses, and the patients' preparation for CT scanning. The use of contrast media is discussed with regard to the possible hazards involved and to the need to hear allergological opinion first. For spinal canal visualization non-ionogenic contrast media are used exclusively. The management of side reactions to contrast medium application is also reviewed. Indications for bone and joint computed tomography now comprise a whole series of traumatological, orthopaedic, oncological, rheumatological, neurological and rehabilitation conditions, each of which is discussed in detail in a separate chapter. CT anatomical studies offer the advantage of being applicable even in patients examined for other than bone or articular diseases. The option of simultaneous soft tissue assessment represents another advantage. The authors describe different anatomical structures in terms of CT images, some of them complete with dimensional and density values. The chapter on anomalies and developmental variants stresses the relevance of computed tomography for precise characteristics of clefts of the spinal column and facial bones and for the diagnosis of anomalies and dysplasias of the spinal column and the chest. A rare case of cephalothoracopagus is demonstrated. As for traumatology, computed tomography is found useful in diagnosing fractures of the

  10. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    -CCTR, showed that coronary CT angiographies accounted for only 23% of all nonregistered cardiac CTs, indicating >90% completeness of coronary CT angiographies in the WDHR-CCTR. The completeness of individual variables varied substantially (range: 0%-100%), but was >85% for more than 70% of all variables. Using......BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... expected numbers; and 4) positive predictive values as well as negative predictive values of 19 main patient and procedure variables. RESULTS: By December 31, 2012, almost 22,000 cardiac CTs with up to 40 variables for each procedure have been registered. Of these, 87% were coronary CT angiography...

  11. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  12. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  13. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  14. Cone beam computed tomography in endodontics.

    Science.gov (United States)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillo-facial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontics. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice.

  15. Computed tomography of ancient Egyptian mummies.

    Science.gov (United States)

    Harwood-Nash, D C

    1979-12-01

    This first report of the application of computed tomography (CT) to the study of ancient mummies, the desiccated brain of a boy and the body of a young woman within her cartonnage, shows that CT is uniquely suitable for the study of such antiquities, a study that does not necessitate destruction of the mummy or its cartonnage. Exquisite images result that are of great paleoanatomical, paleopathological, and archeological significance.

  16. Computed tomography and obstructive biliary disease.

    Science.gov (United States)

    Havrilla, T R; Haaga, J R; Alfidi, R J; Reich, N E

    1977-05-01

    Forty-four patients with confirmed biliary diseases were studied to determine the value of computed tomography (CT) in the diagnosis of biliary pathology. The results indicate that CT is useful and highly accurate in differentiating between obstructive (surgical) and nonobstructive (medical) disease entities. Of the cases with proved obstruction, 88% were correctly identified. All of the nonobstructive cases had positive CT correlation. In addition, the underlying cause of the occlusion was determined in the majority of cases.

  17. Cone Beam Computed Tomography - Know its Secrets

    OpenAIRE

    Kumar, Mohan; Shanavas, Muhammad; Sidappa, Ashwin; Kiran, Madhu

    2015-01-01

    Cone-beam computed tomography (CBCT) is an advanced imaging modality that has high clinical applications in the field of dentistry. CBCT proved to be a successful investigative modality that has been used for dental and maxillofacial imaging. Radiation exposure dose from CBCT is 10 times less than from conventional CT scans during maxillofacial exposure. Furthermore, CBCT is highly accurate and can provide a three-dimensional volumetric data in axial, sagittal and coronal planes. This article...

  18. Computed Tomography of Transverse Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Watts, A. [Fermilab; Johnstone, C. [Fermilab; Johnstone, J. [Fermilab

    2016-09-19

    Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

  19. Cone beam computed tomography use in orthodontics.

    Science.gov (United States)

    Nervina, J M

    2012-03-01

    Cone beam computed tomography (CBCT) is widely used by orthodontists to obtain three-dimensional (3-D) images of their patients. This is of value as malocclusion results from discrepancies in three planes of space. This review tracks the use of CBCT in orthodontics, from its validation as an accurate and reliable tool, to its use in diagnosing and treatment planning, and in assessing treatment outcomes in orthodontics.

  20. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  1. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice.

  2. Evaluation of algebraic iterative image reconstruction methods for tetrahedron beam computed tomography systems.

    Science.gov (United States)

    Kim, Joshua; Guan, Huaiqun; Gersten, David; Zhang, Tiezhi

    2013-01-01

    Tetrahedron beam computed tomography (TBCT) performs volumetric imaging using a stack of fan beams generated by a multiple pixel X-ray source. While the TBCT system was designed to overcome the scatter and detector issues faced by cone beam computed tomography (CBCT), it still suffers the same large cone angle artifacts as CBCT due to the use of approximate reconstruction algorithms. It has been shown that iterative reconstruction algorithms are better able to model irregular system geometries and that algebraic iterative algorithms in particular have been able to reduce cone artifacts appearing at large cone angles. In this paper, the SART algorithm is modified for the use with the different TBCT geometries and is tested using both simulated projection data and data acquired using the TBCT benchtop system. The modified SART reconstruction algorithms were able to mitigate the effects of using data generated at large cone angles and were also able to reconstruct CT images without the introduction of artifacts due to either the longitudinal or transverse truncation in the data sets. Algebraic iterative reconstruction can be especially useful for dual-source dual-detector TBCT, wherein the cone angle is the largest in the center of the field of view.

  3. Evaluation of Algebraic Iterative Image Reconstruction Methods for Tetrahedron Beam Computed Tomography Systems

    Directory of Open Access Journals (Sweden)

    Joshua Kim

    2013-01-01

    Full Text Available Tetrahedron beam computed tomography (TBCT performs volumetric imaging using a stack of fan beams generated by a multiple pixel X-ray source. While the TBCT system was designed to overcome the scatter and detector issues faced by cone beam computed tomography (CBCT, it still suffers the same large cone angle artifacts as CBCT due to the use of approximate reconstruction algorithms. It has been shown that iterative reconstruction algorithms are better able to model irregular system geometries and that algebraic iterative algorithms in particular have been able to reduce cone artifacts appearing at large cone angles. In this paper, the SART algorithm is modified for the use with the different TBCT geometries and is tested using both simulated projection data and data acquired using the TBCT benchtop system. The modified SART reconstruction algorithms were able to mitigate the effects of using data generated at large cone angles and were also able to reconstruct CT images without the introduction of artifacts due to either the longitudinal or transverse truncation in the data sets. Algebraic iterative reconstruction can be especially useful for dual-source dual-detector TBCT, wherein the cone angle is the largest in the center of the field of view.

  4. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS - Schwenke Consulting, Berlin (Germany); Huppertz, Alexander [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); ISI - Imaging Science Institute Charite, Berlin (Germany)

    2014-01-15

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m{sup 2}) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G{sub 30}, 30 mL; G{sub 40}, 40 mL; G{sub 50}, 50 mL; G{sub 60}, 60 mL; G{sub 70}, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G{sub 30} to 478.2 and 571.8 HU in G{sub 70}. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G{sub 30}, G{sub 40}, G{sub 50}, G{sub 60} and G{sub 70} were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  5. Cerebral artery evaluation of dual energy CT angiography with dual source CT

    Institute of Scientific and Technical Information of China (English)

    MA Rui; LIU Cheng; DENG Kai; SONG Shao-juan; WANG Dao-ping; HUANG Ling

    2010-01-01

    Background Conventional computed tomography angiography (CTA) is time consuming, user-dependent and has poor image quality in skull base region. This study assessed the feasibility of a new method, dual energy CTA for depicting the cerebral artery.Methods Phantom scan was done with head CTA sequences on dual source CT and 64 spiral CT for radiation dose calculation. Dual energy CTA was done with dual source CT on 36 patients who were suspected of having cerebral vascular disease. Three series axial images in 0.75 mm thick, 0.4 mm increment were acquired, which were named with 80 kV, 140 kV and merged images; 80 kV and 140 kV images were transferred into dual energy software, and maximum intensity projection (MIP) image was generated quickly by dual energy bone remove (DEBR group); merged images were transferred into In Space software to acquire MIP image through manual conventional bone remove (CoBR group). Post processing time and reading time were compared. Image qualities of the two groups were compared, mainly focusing on skull base segments of internal carotid artery and bone subtraction. ANOVA and SNK tests were applied for radiation dose comparison. Student's t test and Wilcoxon rank sum test were applied for assessing differences between data for significance. Cohen's kappa was used for interobserver agreement. Results Radiation dose of phantom scan showed dual energy CTA was between digital bone subtraction and conventional CTA. The post processing time and reading time were much shorter in DEBR than CoBR, and image quality in skull base was much higher in DEBR than CoBR (P0.5). Interobserver agreement for all vessel segments was excellent (kappa=0.97). Conclusions Dual energy CTA is a reliable, new modality for depicting cerebral artery, overcoming the limitation of conventional CTA in the skull base region. It can save much time in post processing and reading than conventional CTA.

  6. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  7. Quantitative analysis of left ventricular strain using cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buss, Sebastian J., E-mail: sebastian.buss@med.uni-heidelberg.de [Department of Cardiology, University of Heidelberg, 69120 Heidelberg (Germany); Schulz, Felix; Mereles, Derliz [Department of Cardiology, University of Heidelberg, 69120 Heidelberg (Germany); Hosch, Waldemar [Department of Diagnostic and Interventional Radiology, University of Heidelberg, 69120 Heidelberg (Germany); Galuschky, Christian; Schummers, Georg; Stapf, Daniel [TomTec Imaging Systems GmbH, Munich (Germany); Hofmann, Nina; Giannitsis, Evangelos; Hardt, Stefan E. [Department of Cardiology, University of Heidelberg, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich [Department of Diagnostic and Interventional Radiology, University of Heidelberg, 69120 Heidelberg (Germany); Katus, Hugo A.; Korosoglou, Grigorios [Department of Cardiology, University of Heidelberg, 69120 Heidelberg (Germany)

    2014-03-15

    Objectives: To investigate whether cardiac computed tomography (CCT) can determine left ventricular (LV) radial, circumferential and longitudinal myocardial deformation in comparison to two-dimensional echocardiography in patients with congestive heart failure. Background: Echocardiography allows for accurate assessment of strain with high temporal resolution. A reduced strain is associated with a poor prognosis in cardiomyopathies. However, strain imaging is limited in patients with poor echogenic windows, so that, in selected cases, tomographic imaging techniques may be preferable for the evaluation of myocardial deformation. Methods: Consecutive patients (n = 27) with congestive heart failure who underwent a clinically indicated ECG-gated contrast-enhanced 64-slice dual-source CCT for the evaluation of the cardiac veins prior to cardiac resynchronization therapy (CRT) were included. All patients underwent additional echocardiography. LV radial, circumferential and longitudinal strain and strain rates were analyzed in identical midventricular short axis, 4-, 2- and 3-chamber views for both modalities using the same prototype software algorithm (feature tracking). Time for analysis was assessed for both modalities. Results: Close correlations were observed for both techniques regarding global strain (r = 0.93, r = 0.87 and r = 0.84 for radial, circumferential and longitudinal strain, respectively, p < 0.001 for all). Similar trends were observed for regional radial, longitudinal and circumferential strain (r = 0.88, r = 0.84 and r = 0.94, respectively, p < 0.001 for all). The number of non-diagnostic myocardial segments was significantly higher with echocardiography than with CCT (9.6% versus 1.9%, p < 0.001). In addition, the required time for complete quantitative strain analysis was significantly shorter for CCT compared to echocardiography (877 ± 119 s per patient versus 1105 ± 258 s per patient, p < 0.001). Conclusion: Quantitative assessment of LV strain

  8. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  9. Computed tomography angiography of coronary artery bypass grafts: robustness in emergency and clinical routine settings.

    Science.gov (United States)

    Heye, Tobias; Kauczor, Hans-Ulrich; Szabo, Gabor; Hosch, Waldemar

    2014-03-01

    There is a high probability for presence of irregular heart rates and artifacts in patients with previous coronary artery bypass graft (CABG) surgery. Previously reported diagnostic performance of ECG-gated 64-slice dual-source computer tomography angiography (CTA) in this patient group is based on pre-selection for normal heart rate and routine clinical setting. To investigate image quality and diagnostic performance of CTA in patients with previous CABG surgery in various clinical settings. Fifty-six non-selected, consecutive patients (110 grafts, 44 arterial, 66 venous) with previous CABG surgery were prospectively examined using a dual-source 64-slice CT (Siemens Definition, Forchheim, Germany) without utilization of CT-related pharmaceutical heart rate control. Patients were stratified according to the clinical setting: planned redo-cardiac surgery; emergency CTA within 30 days after CABG surgery; routine follow-up after CABG surgery. A reference standard was available for 30 patients (53.6%; 67/110 grafts). Image quality, artifacts, and graft patency were independently assessed by two observers. All CTAs were diagnostic despite the presence of irregular heart rhythm (25% of cases) and artifacts (72.7% of grafts). CTA was accurate in all patient groups in assessing graft patency (97.9% sensitivity; 100% specificity; 98.5% accuracy) but artifacts decreased diagnostic performance for stenosis detection (60% sensitivity; 88.6% specificity; 84.1% accuracy). Arterial grafts exhibited more surgical clip artifacts compared to venous grafts, which predominantly showed motion artifacts. Overall diagnostic quality was rated excellent in 70.9%/56.4%, good in 23.4%/39.1%, and sufficient in 5.5%/4.5% by each observer, respectively. CTA detected acute findings in 10 cases (graft bleeding, graft occlusion, pericardial hematoma, sternal instability with retrosternal abscess formation, pericardial effusion, left ventricle thrombus) in the emergency group; seven cases required

  10. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  11. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...

  12. Computed tomography in neuronal ceroid lipofuscinosis

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neuronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter.

  13. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...... measurement uncertainties in the range 1.5–5.5 μm, showing a good stability over the 6 months of the circulation. The comparison has shown that CT measurements on the industrial parts used lie in the range 6–53 μm, with maximum values up to 158 μm....

  14. Tomography and spectroscopy as quantum computations

    CERN Document Server

    Miquel, C; Saraceno, M; Knill, E H; Laflamme, R; Negrevergne, C; Miquel, Cesar; Paz, Juan Pablo; Saraceno, Marcos; Knill, Emmanuel; Laflamme, Raymond; Negrevergne, Camille

    2001-01-01

    Determining the state of a system and measuring properties of its evolution are two of the most important tasks a physicist faces. For the first purpose one can use tomography, a method that after subjecting the system to a number of experiments determines all independent elements of the density matrix. For the second task, one can resort to spectroscopy, a set of techniques used to determine the spectrum of eigenvalues of the evolution operator. In this letter, we show that tomography and spectroscopy can be naturally interpreted as dual forms of quantum computation. We show how to adapt the simplest case of the well-known phase estimation quantum algorithm to perform both tasks, giving it a natural interpretation as a simulated scattering experiment. We show how this algorithm can be used to implement an interesting form of tomography by performing a direct measurement of the Wigner function of a quantum system. We present results of such measurements performed on a system of three qubits using liquid state...

  15. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  16. COMPUTED TOMOGRAPHY OF TOOTH RESORPTION IN CATS.

    Science.gov (United States)

    Lang, Linda G; Wilkinson, Thomas E; White, Tammy L; Farnsworth, Raelynn K; Potter, Kathleen A

    2016-09-01

    Tooth resorption is the most common dental disease in cats and can be a source of oral pain. The current clinical gold standard for diagnosis includes a combination of oral exam and dental radiography, however early lesions are not always detected. Computed tomography (CT) of the skull, including the dental arches, is a commonly performed diagnostic procedure, however the appearance of tooth resorption on CT and the diagnostic ability of CT to detect tooth resorption have not been evaluated. The purpose of this prospective, descriptive, diagnostic accuracy study was to characterize the CT appearance of tooth resorption in a sample of affected cats and to evaluate the sensitivity and specificity of CT for tooth resorption compared to the clinical gold standard of oral exam and intraoral dental radiography. Twenty-eight cat cadaver specimens were recruited for inclusion. Each specimen was evaluated using oral exam, intraoral dental radiography, and computed tomography (four different slice thicknesses). Each tooth was evaluated for the presence or absence of tooth resorption. Teeth with lesions and a subset of normal teeth were evaluated with histopathology. On CT, tooth resorption appeared as irregularly marginated hypoattenuating defects in the mineral attenuating tooth components, most commonly involving the root or cementoenamel junction. Sensitivity for CT detection of tooth resorption was fair to poor (42.2-57.7%) and specificity was good to excellent (92.8-96.3%). Findings from this study indicated that CT has high specificity but low sensitivity for detection of tooth resorption in cats.

  17. Computed tomography in pelvic and acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Born, H.; Schmidt, C.

    1988-06-01

    In a retrospective study we analyzed the results of 127 patients, who were examined not only by means of conventional radiography but also by means of computed tomography after a trauma of the pelvic. Our investigations were based upon such patients, to whom a definite diagnostic procedure of plain radiography had been performed. Therefore all polytraumatized patients were inapplicable. They were only examined by computed tomography because of other more important accompanying injuries of other body regions. We compared the results of 127 patients with pelvic trauma. The results of the CT were in accordance with the results of the plain radiography for 103 patients. The results of the CT concerning the availability and the localization of the fractures were basically coincident with the plain radiography for 22 patients, but the CT showed a higher degree of trauma and additional intraarticular fragments. Two isolated lesions of the sacroiliac joint could not be recognized by both methods. They could only be diagnosed by bone scintigraphy on the third day after trauma.

  18. SADMFR guidelines for the use of cone-beam computed tomography/ Digital Volume Tomography

    OpenAIRE

    Dula, Karl; Bornstein, Michael M.; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J. Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C.

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the ...

  19. Computed Tomography Technology: Development and Applications for Defence

    Science.gov (United States)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-09-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT&E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  20. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  1. Use of dual-source computed tomography in the diagnosis of cardiovascular diseases%双源CT在心血管疾病诊断中的应用

    Institute of Scientific and Technical Information of China (English)

    俞芸; 李月华

    2009-01-01

    近年,我国冠心病的发病率日渐升高。诊断冠心病的金标准仍为侵人性冠状动脉造影(invasivecoronaryangiography,ICA),但其为有创性检查,仍有一定的风险且费用高。而CT检查为无创的,且费用相对较低.其应用于心脏检查已有近20年的历史。2005年,北美放射学会rRSNA)推出了崭新理念的双源CTdual-sourcecomputedtomographvDSCn。DSCT最突出的特点是时间分辨率高,可达83ms.从而大大提高了心脏CT影像的质量,使这项无创检查更准确。与之前的多排CT相比,DSCT检查结果不受心率影响,扩大了应用人群的范围。

  2. From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography

    Directory of Open Access Journals (Sweden)

    Stephanie Zesch

    2016-01-01

    Conclusion: Our results highlight the enormous progress achieved form earliest to latest imaging technology for advanced mummy research using the first human mummy investigated with X-ray. With the application of DSCT, detailed knowledge regarding age at death, sex, diseases, death, and mummification of a child from Ptolemaic Egypt are revealed while considering the temporary rites of body treatment and burial for children.

  3. Computed tomography in palaeontology - case studies from Triassic to Cretaceous ammonites

    Science.gov (United States)

    Lukeneder, A.; Lukeneder, S.; Gusenbauer, C.

    2012-04-01

    Case studies on computed tomography on ammonites, ammonite mass-occurrences and trace fossils, deposited during the Upper Triassic (approx. 225 mya) of Turkey and during the Lower Cretaceous of Italy (approx. 130 mya), are presented. X-ray computed tomography is known in palaeontology as providing data for 3D visualization and geometrical modelling techniques. Computed tomography down to a few microns (or even below) of spatial resolution are increasingly employed for geoscientific investigations, using an equally variable range of processing techniques and software packages. Additionally internal structures are visualized without destruction of fossils, as computed tomography is a non-destructive method. Experimental The scans were made at the Upper Austria University of Applied Science in Wels with a dual source industrial 3D computed tomography device (RayScan 250 E), equipped with a 225 kV microfocus and a 450 kV minifocus X-ray tube as well as a 2048x2048 pixel flat panel detector (cone beam reconstruction). The spatial resolution (down to 5 μm) is determined by the size of each volumetric pixel (voxel) of the data set. For each fossil part the optimal voxel size and tube voltage were set according to the specimen dimensions. Case study 1: Triassic ammonites from Turkey (FWF Project P22109-B17) A case study in computed tomography on the ammonite genus Orthoceltites is presented. The latter studies are essential for palaeontology and systematic investigations. Ammonite shells and filled phragmocones (secondary calcite) from the Orthoceltites beds possess the same mass-density as the matrix in which the ammonite specimens are embedded. The almost identical mass-density of the embedding matrix (about 2.8 g/cm3), the ammonite shell (secondary calcite, about 2.6-2.8 g/cm3) and the infilled matrix (about 2.8 g/cm3) avoids their visualization. It is therefore not possible to visualize the ammonites by computed tomography. In few cases ammonite shells, body chambers

  4. Use of high-resolution computed tomography and positron emission tomography/computed tomography in the management of stage IA adenocarcinoma.

    Science.gov (United States)

    Miyata, Yoshihiro; Tsutani, Yasuhiro; Okada, Morihito

    2012-01-01

    Preoperative determination of malignant behavior is critical in choosing suitable therapeutic strategies such as sublobar resection for patients with small lung cancers. The aim of present review was to evaluate high-resolution computed tomography and fluorodeoxyglucose-positron emission tomography/computed tomography as tools for management of clinical stage IA adenocarcinoma.

  5. Spatiotemporal computed tomography of dynamic processes

    Science.gov (United States)

    Kaestner, Anders; Münch, Beat; Trtik, Pavel; Butler, Les

    2011-12-01

    Modern computed tomography (CT) equipment allowing fast 3-D imaging also makes it possible to monitor dynamic processes by 4-D imaging. Because the acquisition time of various 3-D-CT systems is still in the range of at least milliseconds or even hours, depending on the detector system and the source, the balance of the desired temporal and spatial resolution must be adjusted. Furthermore, motion artifacts will occur, especially at high spatial resolution and longer measuring times. We propose two approaches based on nonsequential projection angle sequences allowing a convenient postacquisition balance of temporal and spatial resolution. Both strategies are compatible with existing instruments, needing only a simple reprograming of the angle list used for projection acquisition and care with the projection order list. Both approaches will reduce the impact of artifacts due to motion. The strategies are applied and validated with cold neutron imaging of water desorption from originally saturated particles during natural air-drying experiments and with x-ray tomography of a polymer blend heated during imaging.

  6. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  7. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  8. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...... have become the standard with which to assess emphysema extent but airway abnormalities have so far been more challenging to quantify. Automated methods for analysis are indispensable as the visible airway tree in a CT scan can include several hundreds of individual branches. However, automation...... of scan on airway dimensions in subjects with and without COPD. The results show measured airway dimensions to be affected by differences in the level of inspiration and this dependency is again influenced by COPD. Inspiration level should therefore be accounted for when measuring airways, and airway...

  9. Findings of computed tomography in intracranial tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Jo, H. G.; Bae, K. S.; Lee, H. K.; Kwon, K. H.; Kim, K. J. [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    In intracranial tuberculosis, the Computed Tomography (CT) is a new radiological technique which is helpful in diagnosis and determining the location, extents of the lesion. It can also make it possible to assess the presence and degree of the complications and to evaluate the effectiveness of treatment. 25 cases of clinically proven intracranial tuberculosis were studied by CT, in Soonchunhyang hospital from Jun. 1980 to Jun. 1983. The result were as follows; 1. 4 cases were normal in CT finding, despite of the clinically proven tuberculous meningitis. 2. Total or partial obliteration of cisterns were observed in 13 cases. 3. Intense abnormal contrast enhancement of the cisterns were observed in 8 cases. 4. 19 cases show moderate to marked ventricular dilatation. 5. 2 cases of cerebral infarction were observed. 6. One case of tuberculoma was observed.

  10. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...... concerns measurements of each single carcass, to improve the raw material utilisation by individually adapted processing. Measurements performed online in the abattoir demand fast, robust and cost-effective imaging. We propose a tomographic reconstruction algorithm, enabling a substantial reduction...... of the subject-specific X-ray data needed to produce high quality images for accurate measurements. This is very beneficial for the abattoirs, as a reduction in acquired data translates directly into higher speed and a lower cost. The thesis demonstrates the great potential of CT as a technology for improving...

  11. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...... table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique...... for assessment of vascularity. CT perfusion has also been used for tumor characterization, staging of disease, response evaluation of newer drugs targeted towards angiogenesis and as a method for early detection of recurrence after radiation and embolization. There are several software solutions available...

  12. Computed tomography in metastatic renal cell carcinoma.

    Science.gov (United States)

    Griffin, Nyree; Grant, Lee Alexander; Bharwani, Nishat; Sohaib, S Aslam

    2009-08-01

    Recent developments in chemotherapy have resulted in several new drug treatments for metastatic renal cell carcinoma (RCC). These therapies have shown improved progression-free survival and are applicable to many more patients than the conventional cytokine-based treatments for metastatic RCC. Consequently imaging is playing a greater part in the management of such patients. Computed tomography (CT) remains the primary imaging modality with other imaging modalities playing a supplementary role. CT is used in the diagnosis and staging of metastatic RCC. It is used in the follow-up of patients after nephrectomy, in assessing the extent of metastatic disease, and in evaluating response to treatment. This review looks at the role of CT in patients with metastatic RCC and describes the appearances of metastatic RCC before and following systemic therapy.

  13. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  14. Reconstructing cetacean brain evolution using computed tomography.

    Science.gov (United States)

    Marino, Lori; Uhen, Mark D; Pyenson, Nicholas D; Frohlich, Bruno

    2003-05-01

    Until recently, there have been relatively few studies of brain mass and morphology in fossil cetaceans (dolphins, whales, and porpoises) because of difficulty accessing the matrix that fills the endocranial cavity of fossil cetacean skulls. As a result, our knowledge about cetacean brain evolution has been quite limited. By applying the noninvasive technique of computed tomography (CT) to visualize, measure, and reconstruct the endocranial morphology of fossil cetacean skulls, we can gain vastly more information at an unprecedented rate about cetacean brain evolution. Here, we discuss our method and demonstrate it with several examples from our fossil cetacean database. This approach will provide new insights into the little-known evolutionary history of cetacean brain evolution.

  15. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  16. Ultra-high resolution computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  17. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...... - CIA-CT”. In the comparison, 27 laboratories from 8 countries were involved, and CT scanned two items selected among common industrial parts: a polymer part and a metal part. Altogether, 27 sets of items were circulated in parallel to the participants. Different measurands are considered, encompassing...... influence from the surrounding wall thickness on the measurement of roundness was documented for the metal item. The comparison shows that CT scanning on small industrial parts, generally speaking, is connected with uncertainties in the range 8-53 μm, as compared to an uncertainty range of 1.5-5.5 μm using...

  18. Intravenous coronary angiography using electron beam computed tomography

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A H; van Geuns, R J; van Ooijen, P M; Oudkerk, M; de Feyter, P J

    1999-01-01

    Intravenous coronary angiography with electron beam computed tomography (EBCT) allows for the noninvasive visualisation of coronary arteries. With dedicated computer hardware and software, three-dimensional renderings of the coronary arteries, veins, and other cardiac structures can be constructed f

  19. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  20. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J.N.; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  1. Computed tomography in traumatic defects of the diaphragm.

    Science.gov (United States)

    Demos, T C; Solomon, C; Posniak, H V; Flisak, M J

    1989-03-01

    Two patients with traumatic diaphragmatic defects visible on computed tomography are presented. The diagnosis was delayed for several years in both patients. The diagnosis of these acquired diaphragmatic defects is often difficult. Computed tomography can lead to earlier diagnosis by demonstrating the defect in some patients when radiographic studies are not diagnostic.

  2. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  3. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on t

  4. X-Ray Computed Tomography for Advanced Materials and Processes.

    Science.gov (United States)

    1992-06-30

    percent. In this example, we have assumed $I M, $5(X)K and $200K CT systems operating at 10 percent of the capital investment per year for maintenance...Computed Tomo &:aphy of Composites," WRDC-TR-90-4014, July 1990. 5. P. Burstein and R. H. Bossi, "A Guide to Computed Tomography System Specifications," WRDC...Lannutti, "Applications of High- Resolution Computed Tomography," Proceedings of the 1991 Industrial Computed Tomography II Topical Conference, May 20-24

  5. Micro computed tomography for vascular exploration

    Directory of Open Access Journals (Sweden)

    Zhuang Zhen W

    2010-03-01

    Full Text Available Abstract Vascular exploration of small animals requires imaging hardware with a very high spatial resolution, capable of differentiating large as well as small vessels, in both in vivo and ex vivo studies. Micro Computed Tomography (micro-CT has emerged in recent years as the preferred modality for this purpose, providing high resolution 3D volumetric data suitable for analysis, quantification, validation, and visualization of results. The usefulness of micro-CT, however, can be adversely affected by a range of factors including physical animal preparation, numerical quantification, visualization of results, and quantification software with limited possibilities. Exacerbating these inherent difficulties is the lack of a unified standard for micro-CT imaging. Most micro-CT today is aimed at particular applications and the software tools needed for quantification, developed mainly by imaging hardware manufacturers, lack the level of detail needed to address more specific aims. This review highlights the capabilities of micro-CT for vascular exploration, describes the current state of imaging protocols, and offers guidelines and suggestions aimed at making micro-CT more accurate, replicable, and robust.

  6. Radiation doses from computed tomography in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J.E.M.; Tingey, D.R.C

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors) 28 refs., 11 tabs., 10 figs.

  7. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  8. Computed tomography characterisation of additive manufacturing materials.

    Science.gov (United States)

    Bibb, Richard; Thompson, Darren; Winder, John

    2011-06-01

    Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.

  9. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  10. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  11. Virtual computed tomography cystoscopy in bladder pathologies

    Directory of Open Access Journals (Sweden)

    Halil Arslan

    2006-04-01

    Full Text Available OBJECTIVE: Assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT in patients with different urinary bladder pathologies compared to the conventional cystoscopy. MATERIALS AND METHODS: Eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. RESULTS: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88% of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. CONCLUSION: Virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion.

  12. Virtual computed tomography cystoscopy in bladder pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban [Yuzuncu Yil University School of Medicine, Van (Turkey). Dept. of Radiology and Urology]. E-mail: drhalilarslan@hotmail.com

    2006-03-15

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  13. Application of computed tomography to spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Sha, N.; Kurihara, A.; Kataoka, O. (Kobe Univ. (Japan). School of Medicine)

    1980-08-01

    The axial tomographic examination of the spine and its soft tissues is now readily available for orthopaedic surgery. If the appropriate conditions are maintained, computed tomography (CT) can provide useful information concerning the diagnosis and the treatment of spinal diseases. There are, however, some pitfalls in interpreting CT scans: 1) the existence of the lesion may be masked, and 2) its extent and configuration may be over- or under-evaluated depending on such technical factors as the slicing level, the slicing angle, the window width, and the window level. Experimental studies were carried out on a plaster of Paris model of the spine and a cadaver spine to determine the appropriate technical factors by which the CT (EMI whole body CT scanner 5005) can be applied accurately to a diseased spine. The factors obtained were then applied in examining ninety-nine patients with various spinal disorders. Window levels ranging between 100 and 150 were found to be most appropriate. The slicing angle should be 90/sup 0/, or perpendicular to the long axis of the object under study. However, deviations of +10 or -10 degrees are acceptable. The CT view of the spine may be divided into two patterns at the cervical and thoracic levels and into three patterns at the lumbar level. In addition, the usefulness and the diagnostic value of CT for various spinal problems are discussed based on our clinical material.

  14. Computed tomography in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, Karl-Olof [HUG-Geneva University Hospital, Geneva University Medical School, Department of Neuroradiology, Department of Imaging and Medical Informatics, Geneva (Switzerland); Baird, Alison E. [SUNY Downstate Medical Center, Cerebrovascular Disease and Stroke, 450 Clarkson Avenue, Box 1213, Brooklyn, NY (United States)

    2010-03-15

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  15. Application of computed tomography in paleoanthropological research

    Institute of Scientific and Technical Information of China (English)

    Xiujie Wu; Lynne A.Schepartz

    2009-01-01

    Hominin fossils are the most important materials for exploring questions about human origins and evolution. Because human fossils are very rare, it is impossible to use highly destructive techniques in order to study their morphology. Traditional analyses can only rely on the information gained from the study of the external morphology of specimens, and these approaches limited the study of human evolution. The application of computed tomography (CT) has facilitated major developments in paleoanthropology. To date, few studies on Chinese hominin fossils have used CT scanning methodology, but this is rapidly changing. In order to better understand the appli-cation of CT methodology in paleoanthropology, we review the applications of CT scanning on hominin fossils throughout the world.Studies examined include virtual fossil reconstruction, the use of endocasts to elucidate brain morphology, biomechanical analyses of bone distribution, imaging of mummies and research on early human health, and skeletal and dental microanatomical research.2009 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.

  16. Computed tomography of the orbital lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Eon; Suh, Soo Jhi; Kim, Ho Kyun; Kim, Soon Yong [Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    1980-06-15

    The use of computed tomography in investigation of orbital lesions was of value for the localization of the lesions as well as making the specific diagnosis. We advocated the combined use of transverse axial section and contrast enhancement in CT as a routine procedure often including coronal section in the diagnosis of orbital lesions because of its usefulness and more precise three dimensional imaging. The authors examined 68 patients with various ophthalmic problems by EMI-CT scanner 5005 from October 1977 to November 1979. Fifty one orbital lesions out of 68 CT scans were analyzed by CT, angiography and operative findings and results were as follows; 1. Among 43 males and 25 females, their age range was from 4 months to 66 years with the most frequent age group of first decade (17 cases; 25%) 2. The distribution of the lesions was mucocele, pseudotumor, optic nerve atrophy, metastasis, lacrimal gland tumor, persistent hypertrophic primary vitreous, granulosa cell myoblastoma, hemangioma in order with 13 malignancies (25%). 3. It was difficult to differentiate pathological diagnosis of the lesions, but the character of the lesions was determined by its characteristic location, and its relationship to eyeball, optic nerve, extraocular muscles and bony orbit. 4. It was thought that more accurate diagnosis of orbital lesions could be made by development of CT scanner having fine matrix, short time exposure and thin slice in the future.

  17. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  18. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  19. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  20. Computer tomography-aided ventriculography and cisternography

    Energy Technology Data Exchange (ETDEWEB)

    Cernoch, Z.; Sercl, M.; Heger, L.; Parizek, J. (Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta)

    1983-01-28

    Computer tomography was used in 42 patients for the exploration of ventricular and subarachnoidal spaces following intraventricular, lumbar or suboccipital injections of 3 to 5 ml Amipaque using the kind of manoeuvre to permit optimum filling of the region concerned. This type of CT ventriculo- or cisternography is a significant supplement to plain CT examination particularly because it supplies data on the causes of CSF passage blocks. Thus, in two female patients it proved possible to localize cysts in the 3rd ventricle, the density of which was no different from that of CSF. As regards benign stenoses of the aqueduct, it is likely to yield less information than conventional specific ventriculography. On the other hand, the technique gives perfect visualization of all possible communications between pathological intracranial cavities and the ventricular system. CT cisternography proved useful for the identification of small-size isodense growths in the region of the sella turcica, and brought convincing evidence of the causes of profuse liquorrhea by demonstrating the presence of nasal meningocele. It was also found helpful in the analysis of the craniocervical region, otherwise difficult to survey.

  1. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  2. A Detector for Proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blazey, G.; et al.

    2013-12-06

    Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

  3. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  4. Diffuse abnormalities of the trachea: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@gmail.com; Pozes, Aline Serfaty [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Escola de Medicina. Dept. de Radiologia; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Radiologia; Irion, Klaus Loureiro [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Barillo, Jorge Luiz; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). Dept. de Cirurgia Clinica; Souza, Carolina Althoff [University of Ottawa, Ottawa, ON (Canada)

    2008-01-15

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  5. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings*

    Science.gov (United States)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tânia Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanês, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mário Flores

    2015-01-01

    Objective To evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and Methods Retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results Abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion Computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. PMID:25987748

  6. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  7. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  8. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  9. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    2005-01-01

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic mo

  10. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  11. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas;

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...

  12. The Use of GPUs for Solving the Computed Tomography Problem

    Directory of Open Access Journals (Sweden)

    A.E. Kovtanyuk

    2014-07-01

    Full Text Available Computed tomography (CT is a widespread method used to study the internal structure of objects. The method has applications in medicine, industry and other fields of human activity. In particular, Electronic Imaging, as a species CT, can be used to restore the structure of nanosized objects. Accurate and rapid results are in high demand in modern science. However, there are computational limitations that bound the possible usefulness of CT. On the other hand, the introduction of high-performance calculations using Graphics Processing Units (GPUs provides improving quality and performance of computed tomography investigations. Moreover, parallel computing with GPUs gives significantly higher computation speeds when compared with (Central Processing Units CPUs, because of architectural advantages of the former. In this paper a computed tomography method of recovering the image using parallel computations powered by NVIDIA CUDA technology is considered. The implementation of this approach significantly reduces the required time for solving the CT problem.

  13. Single-photon emission computed tomography/computed tomography in brain tumors.

    Science.gov (United States)

    Schillaci, Orazio; Filippi, Luca; Manni, Carlo; Santoni, Riccardo

    2007-01-01

    Anatomic imaging procedures (computed tomography [CT] and magnetic resonance imaging [MRI]) have become essential tools for brain tumor assessment. Functional images (positron emission tomography [PET] and single-photon emission computed tomography [SPECT]) can provide additional information useful during the diagnostic workup to determine the degree of malignancy and as a substitute or guide for biopsy. After surgery and/or radiotherapy, nuclear medicine examinations are essential to assess persistence of tumor, to differentiate recurrence from radiation necrosis and gliosis, and to monitor the disease. The combination of functional images with anatomic ones is of the utmost importance for a full evaluation of these patients, which can be obtained by means of imaging fusion. Despite the fast-growing diffusion of PET, in most cases of brain tumors, SPECT studies are adequate and provide results that parallel those obtained with PET. The main limitation of SPECT imaging with brain tumor-seeking radiopharmaceuticals is the lack of precise anatomic details; this drawback is overcome by the fusion with morphological studies that provide an anatomic map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT or MRI demonstrated usefulness for brain tumor assessment, but this process is often time consuming and not practical for everyday nuclear medicine studies. The recent development of dual-modality integrated imaging systems, which allow the acquisition of SPECT and CT images in the same scanning session, and their co-registration by means of the hardware, has facilitated this process. In SPECT studies of brain tumors with various radiopharmaceuticals, fused images are helpful in providing the precise localization of neoplastic lesions, and in excluding the disease in sites of physiologic tracer uptake. This information is useful for optimizing diagnosis, therapy monitoring, and radiotherapy treatment planning, with a

  14. Computed tomography (CT) and diastematomyelia's diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S. (Rio de Janeiro Univ. (Brazil). Faculdade de Medicina); Barros, A.P. de (Rio de Janeiro Univ. (Brazil). Hospital Universitario)

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized.

  15. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  16. Perfusion computed tomography to assist decision making for stroke thrombolysis

    Science.gov (United States)

    Levi, Christopher; Krishnamurthy, Venkatesh; McElduff, Patrick; Miteff, Ferdi; Spratt, Neil J.; Bateman, Grant; Donnan, Geoffrey; Davis, Stephen; Parsons, Mark

    2015-01-01

    The use of perfusion imaging to guide selection of patients for stroke thrombolysis remains controversial because of lack of supportive phase three clinical trial evidence. We aimed to measure the outcomes for patients treated with intravenous recombinant tissue plasminogen activator (rtPA) at a comprehensive stroke care facility where perfusion computed tomography was routinely used for thrombolysis eligibility decision assistance. Our overall hypothesis was that patients with ‘target’ mismatch on perfusion computed tomography would have improved outcomes with rtPA. This was a prospective cohort study of consecutive ischaemic stroke patients who fulfilled standard clinical/non-contrast computed tomography eligibility criteria for treatment with intravenous rtPA, but for whom perfusion computed tomography was used to guide the final treatment decision. The ‘real-time’ perfusion computed tomography assessments were qualitative; a large perfusion computed tomography ischaemic core, or lack of significant perfusion lesion-core mismatch were considered relative exclusion criteria for thrombolysis. Specific volumetric perfusion computed tomography criteria were not used for the treatment decision. The primary analysis compared 3-month modified Rankin Scale in treated versus untreated patients after ‘off-line’ (post-treatment) quantitative volumetric perfusion computed tomography eligibility assessment based on presence or absence of ‘target’ perfusion lesion-core mismatch (mismatch ratio >1.8 and volume >15 ml, core perfusion computed tomography-selected rtPA-treated patients to an Australian historical cohort of non-contrast computed tomography-selected rtPA-treated patients. Of 635 patients with acute ischaemic stroke eligible for rtPA by standard criteria, thrombolysis was given to 366 patients, with 269 excluded based on visual real-time perfusion computed tomography assessment. After off-line quantitative perfusion computed tomography classification

  17. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  18. Computed tomography and childhood seizure disorder in Ibadan ...

    African Journals Online (AJOL)

    Computed tomography and childhood seizure disorder in Ibadan. ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING ... the subjects who had cranial scans done in five years were children with seizures disorders.

  19. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques...

  20. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  1. A Clinical Evaluation of Cone Beam Computed Tomography

    Science.gov (United States)

    2013-07-31

    multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011;40:67-75...submitted to the Faculty of the Endodontics Graduate Program Naval Postgraduate Dental School Uniformed Services University of the Health Sciences...in partial fulfillment of the requirements of the degree of Master of Science in Oral Biology June 2013 Naval Postgraduate Dental

  2. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  3. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints. Vergleich von konventioneller Tomographie und Computertomographie bei Erkrankungen der Sakroiliakalgelenke

    Energy Technology Data Exchange (ETDEWEB)

    Moritz, J.D.; Ganter, H.; Winter, C. (Bundeswehrkrankenhaus, Giessen (Germany, F.R.). Roentgenabteilung Evangelisches Krankenhaus, Giessen (Germany, F.R.). Roentgenabteilung)

    1990-10-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.).

  4. Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom

    Directory of Open Access Journals (Sweden)

    Martin Beeres

    2015-01-01

    Full Text Available Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT in imaging of the abdomen. Materials and Methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany. The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated. Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV - at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs. Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised.

  5. High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Karlo, Christoph; Leschka, Sebastian; Goetti, Robert Paul; Feuchtner, Gudrun; Desbiolles, Lotus; Stolzmann, Paul; Marincek, Borut; Baumueller, Stephan [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Plass, Andre; Falk, Volkmar [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Group, Boston, MA (United States)

    2011-01-15

    To compare image quality and radiation dose of high-pitch computed tomography angiography(CTA) of the aortic valve-aortic root complex with and without prospective ECG-gating compared to a retrospectively ECG-gated standard-pitch acquisition. 120 patients(mean age 68 {+-} 13 years) were examined using a 128-slice dual-source CT system using prospectively ECG-gated high-pitch(group A; n = 40), non-ECG-gated high-pitch(group B; n = 40) or retrospectively ECG-gated standard-pitch(C; n = 40) acquisition techniques. Image quality of the aortic root, valve and ascending aorta including the coronary ostia was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. Interobserver agreement was good({kappa} = 0.64-0.78). Image quality was diagnostic in 38/40 patients(group A), 37/40(B) and 38/40(C) with no significant difference in number of patients with diagnostic image quality among all groups (p = 0.56). Significantly more patients showed excellent image quality in group A compared to groups B and C(each, p < 0.01). Average image noise was significantly different between all groups(p < 0.05). Mean radiation dose estimates in groups A and B(each; 2.4 {+-} 0.3 mSv) were significantly lower compared to group C(17.5 {+-} 4.4 mSv; p < 0.01). High-pitch dual-source CTA provides diagnostic image quality of the aortic valve-aortic root complex even without ECG-gating at 86% less radiation dose when compared to a standard-pitch ECG-gated acquisition. (orig.)

  6. Spatial Distribution of Iron Within the Normal Human Liver Using Dual-Source Dual-Energy CT Imaging.

    Science.gov (United States)

    Abadia, Andres F; Grant, Katharine L; Carey, Kathleen E; Bolch, Wesley E; Morin, Richard L

    2017-05-29

    Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers. Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported. The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%). Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.

  7. [The value of dual-source dual-energy CT with iodine overlay in the diagnosis of acute necrotizing pancreatitis].

    Science.gov (United States)

    Yuan, Yuan; Huang, Zi-Xing; Li, Zhen-Lin; Song, Bin; Deng, Li-Ping

    2012-07-01

    To investigate the clinical value of dual-source computed tomography dual-energy Iodine overlay technique in the imaging diagnosis of acute necrotizing pancreatitis. The imaging data were retrospectively analyzed in 67 cases of acute necrotizing pancreatitis underwent contrast-enhanced dual-source dual-energy CT in portal venous phase. The CT imaging parameters, including the difference of CT value between pancreatic parenchyma and necrotic lesion, contrast-to-noise ratio of pancreatic parenchyma-to-necrosis, area of pancreatic necrosis and score of subjective diagnosis, were measured and assessed on CT images of 80 kV, 140 kV, weighted-average 120 kV as well as Iodine overlay. The differences of CT value between pancreatic parenchyma and necrosis in the images of 80 kV, 140 kV, weighted-average 120 kV and Iodine overlay were (67.40 +/- 20.82) HU, (42.87 +/- 14.99) HU, (48.69 +/- 15.82) HU, (33.01 +/- 10.26) HU, respectively; contrast-to-noise ratios of pancreatic parenchyma-to-necrosis of each group were 8.36 +/- 3.58, 5.85 +/- 2.65, 7.68 +/- 3.51, 10.60 4.34; area of pancreatic necrosis of each group was (3.78 +/- 2.68) cm2, (3.28 +/- 2.59) cm2, (3.37 +/- 2.46) cm2, (2.42 +/- 1.98) cm2; the score of subjective diagnosis of each group was 3.88 +/- 0.33, 3.31 +/- 0.80, 3.58 +/- 0.66, 2.81 +/- 0.76, respectively. The four indexes in the images of Iodine overlay were significantly different from those of another three groups (P overlay was significantly higher than that of another three groups, while the difference of CT value, area of pancreatic necrosis and score of subjective diagnosis were lower. CONCLUSION; Dual-source CT dual-energy Iodine overlay is not helpful to improve subjective judgment in the diagnosis of pancreatic necrosis, but contributes to the display of hypoperfusion area around the necrosis.

  8. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  9. Incidence of blunt craniocervical artery injuries: use of whole-body computed tomography trauma imaging with adapted computed tomography angiography.

    Science.gov (United States)

    Fleck, Steffen K; Langner, Soenke; Baldauf, Joerg; Kirsch, Michael; Kohlmann, Thomas; Schroeder, Henry W S

    2011-09-01

    The incidence of traumatic craniocervical artery dissection varies in published trauma series. To determine the frequency of traumatic craniocervical artery injury in polytrauma patients by using standardized whole-body trauma computed tomography with adapted computed tomography angiography of the craniocervical vessels. A total of 718 consecutive patients requiring whole-body trauma computed tomography (16-row multislice) because of the mechanism of their injury patterns and an Injury Severity Scale score greater than 16 were analyzed prospectively. After a cranial scan, computed tomography angiography of the craniocervical vessels with 40 mL of iodinated contrast agent was performed using bolus tracking. The overall incidence of blunt carotid and vertebral injuries (BCVIs) in the screened population was 1.7%. BCVIs were observed in 27.3% of patients with detected isolated cervical spine injuries and in 3.9% of patients with isolated cranial fractures with or without intracranial hemorrhage, whereas 5.3% of patients with combined cervical and cranial lesions were associated with BCVIs. In addition, 0.4% of BCVIs occurred in patients without evidence of head or neck trauma. Whole-body trauma computed tomography with an adapted scanning protocol for the craniocervical vessels is a fast, safe, and feasible method for detecting vascular injuries. It allows prompt further treatment if necessary. Computed tomography angiography could be a part of a broad screening protocol for craniocervical vessels in documented injuries of the head and neck and in trauma mechanisms influencing the craniocervical region as well.

  10. 双源计算机断层扫描在永存动脉干诊断中的应用%Clinical application of dual-source CT in diagnosis of persistent truncus arteriosus

    Institute of Scientific and Technical Information of China (English)

    冯越; 刘铁; 翟利浩

    2012-01-01

    Objectives To explore the clinical values of dual - source computed tomography ( CT) in diagnosis of persistent truncus arteriosus(PTA). Methods Seven patients (aged 7 days to 8 years, middle age 3.4 years) diagnosed as PTA by echocardiography underwent cardiac CT with dual-source CT machine. Two- and three-dimensional images were reformated by multiple planar reformation (coronal, sagital and oblique), maximum intensity projection and volume rendering. Of the 7 patients, 4 underwent angiocardiography. Results Qualitative and classification diagnosis were made through Dual-source CT in all the 7 cases. Dual-source CT visualized 28 concomitant anomalies while echocardiography visualized 24 in all the 7 cases. Conclusions Qualitalive and classification diagnosis can be made through Dual-source CT which contributes to the strategies and improvement of operations.%目的 探讨双源计算机断层扫面(computed tomography,CT)在永存动脉干诊断中的应用价值.方法 选择7例经超声心动图诊断为永存动脉干患者,年龄7d~8岁,中位年龄3.4岁.采用双源CT,心电门控下对比增强完成心脏检查,并在图像工作站完成多平面(MPR)、最大密度投影(MIP)和三维容积漫游(VR)处理.其中有4例进行心导管检查.结果 双源CT对7例永存动脉干均作出定性诊断和分型诊断,共发现合并畸形28处.超声心动图共显示24处.结论 双源CT可以对永存动脉干患者作出准确诊断及分型,并有助于临床手术方案的制订与完善.

  11. Foveola pharyngea - demonstration in conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fiegler, W.; Stolle, E.

    1980-08-01

    The foveola pharyngea is a cavity on the underside of the clivus, located before the tuberculum pharyngeum and, as a larger pit it was detectable in approx. 1% overall in approx. 4% of the personally examined X-rays (11/284) and computed tomograms (6/154) of the skull base. The canalis basilaris medianus inferior and canalis basilaris medianus bifurcatus almost always empties into one of the three forms of the foveola pharyngea (foveola pharyngea infundibuliformis posterior). The differential diagnosis to canalis basilaris medianus, canalis craniopharyngeus, sutura sphenooccipitalis and bone destruction is discussed.

  12. Assessment of aortic stenosis after aortic valve replacement. Comparative evaluation of dual-source CT and echocardiography; Quantitative Evaluation der Aortenklappenoeffnungsflaeche mit der Dual-Source-CT und Korrelation mit der 2D-Echokardiografie. Initiale Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Saam, T.; Minaifar, N.; Becker, C.; Reiser, M.; Nikolaou, K. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie; Oberhoffer, M.; Rist, C.; Vogt, F.; Reichart, B. [Ludwig-Maximilians-Univ. Muenchen (Germany). Herzchirurgische Klinik und Poliklinik

    2008-06-15

    Purpose: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with dual-source computed tomography (DSCT) correlate with measurements obtained by echocardiography and to correlate the amount of calcification of the aortic valve with AVA in a group of patients after aortic valve replacement. Materials and Method: 23 patients underwent dual-source computed tomography (DSCT) of the heart (Somatom Definition, Siemens Medical Solutions, Forchheim, Germany), without heart rate control (heart rate 52-113 beats/minute). All patients had undergone aortic valve replacement (homografts, mean time after surgery: 7{+-}3 years). The AVA of the transplanted aortic valve graft was measured planimetrically by means of DSCT and compared with echocardiography as a standard of reference, to exclude post-surgical restenosis of the valve. Maximum AVA in systole planimetrically measured with CT was compared with calculated AVA values determined with the continuity equation, using transvalvular pressure gradients. The amount of calcification of the aortic valve was quantified and correlated (Spearman's R) with the AVA. To assess intra- and inter-reader reproducibility, the DCST data was re-analyzed by two readers 4 weeks after the initial review. Results: All DSCT datasets were of diagnostic image quality concerning valve depiction. The mean AVA as measured by DSCT was 2.7{+-}0.9 cm{sup 2} compared to 1.8{+-}0.5 cm{sup 2} by echocardiography (p<0.05). The planimetric evaluation of the CT data as compared to results of echocardiography showed a significant correlation of the results (Pearson's correlation coefficient R=0.78, p<0.001). Intra- and inter-reader reproducibility was good with intra-class correlation coefficients of 0.86 and 0.81, respectively (p<0.001). There was a significant negative correlation between the amount of aortic valve calcification and AVA as measured by echocardiography (R=-0.42; p<0.05) and as measured by DSCT (R=-0

  13. Development of a proton Computed Tomography Detector System

    CERN Document Server

    Naimuddin, Md; Blazey, G; Boi, S; Dyshkant, A; Erdelyi, B; Hedin, D; Johnson, E; Krider, J; Rukalin, V; Uzunyan, S A; Zutshi, V; Fordt, R; Sellberg, G; Rauch, J E; Roman, M; Rubinov, P; Wilson, P

    2015-01-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  14. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  15. Development of a proton Computed Tomography detector system

    Science.gov (United States)

    Naimuddin, Md.; Coutrakon, G.; Blazey, G.; Boi, S.; Dyshkant, A.; Erdelyi, B.; Hedin, D.; Johnson, E.; Krider, J.; Rukalin, V.; Uzunyan, S. A.; Zutshi, V.; Fordt, R.; Sellberg, G.; Rauch, J. E.; Roman, M.; Rubinov, P.; Wilson, P.

    2016-02-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  16. Evaluating iterative reconstruction performance in computed tomography.

    Science.gov (United States)

    Chen, Baiyu; Ramirez Giraldo, Juan Carlos; Solomon, Justin; Samei, Ehsan

    2014-12-01

    Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d'). d' was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1-4 mm), contrast levels (10-100 HU), and edge profiles (sharp and soft). Unique d' values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDIvol: 3.4-64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d' values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction potentials (11-54 mGy, 77%-84%), followed by

  17. Quantitative assessment of pure aortic valve regurgitation with dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z., E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Huang, L.; Chen, X.; Xia, C.; Yuan, Y.; Shuai, T. [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2012-07-15

    Aim: To assess the severity of pure aortic regurgitation by measuring regurgitation volumes (RV) and fractions (RF) with dual-source computed tomography (DSCT) as compared to magnetic resonance imaging (MRI) and echocardiography. Materials and methods: Thirty-eight patients (15 men, 23 women; mean age 46 {+-} 11 years) with isolated aortic valve regurgitation underwent retrospectively electrocardiogram (ECG)-gated DSCT, echocardiography, and MRI. Stroke volumes of the left and right ventricles were measured at DSCT and MRI. Thus, RVs and RFs were calculated and compared. The agreement between DSCT and MRI was tested by intraclass correlation coefficient and Bland-Altman analyses. Spearman's rank order correlation and weighted {kappa} tests were used for testing correlations of AR severity between DSCT results and corresponding echocardiographic grades. Results: The RV and RF measured by DSCT were not significantly different from those measured using MRI (p = 0.71 and 0.79). DSCT correlated well with MRI for the measurement of RV (r{sub I} = 0.86, p<0.001) and calculation of the RF (r{sub I} =0.90, p<0.001). Good agreement between the techniques was obtained by using Bland-Altman analyses. The severity of regurgitation estimated by echocardiography correlated well with DSCT (r{sub s} = 0.95, p<0.001) and MRI (r{sub s} = 0.95, p<0.001). Inter-technique agreement between DSCT and two-dimensional transthoracic echocardiography (2DTTE) regarding the grading of the severity of AR was excellent ({kappa} = 0.90), and good agreement was also obtained between MRI and 2DTTE assessments of the severity of AR ({kappa} = 0.87). Conclusion: DSCT using a volume approach can be used to quantitatively determine the severity of pure aortic regurgitation when compared with MRI and echocardiography.

  18. Coronary lesion complexity assessed by SYNTAX score in 256-slice dual-source MDCT angiography

    Science.gov (United States)

    Yüceler, Zeyneb; Kantarcı, Mecit; Tanboğa, İbrahim Halil; Sade, Recep; Kızrak, Yeşim; Pirimoğlu, Berhan; Bayraktutan, Ümmügülsüm; Oğul, Hayri; Aksakal, Enbiya

    2016-01-01

    PURPOSE The SYNTAX Score (SS) has an important role in grading the complexity of coronary artery disease (CAD) in patients undergoing revascularization. Noninvasive determination of SS prior to invasive coronary angiography (ICA) might optimize patient management. We aimed to evaluate the agreement between ICA and multidetector computed tomography (MDCT) while testing the diagnostic effectiveness of SS-MDCT. METHODS Our study included 108 consecutive patients who underwent both MDCT angiography with a 256-slice dual-source MDCT system and ICA within 14±3 days. SS was calculated for both ICA and MDCT coronary angiography. Spearman’s rank correlation coefficient was used to evaluate the association of SS-MDCT with SS-ICA, and Bland-Altman analysis was performed. RESULTS The degree of agreement between SS-ICA and SS-MDCT was moderate. The mean SS-MDCT was 14.5, whereas the mean SS-ICA was 15.9. After dividing SS into three groups (high [≥33], intermediate [23–32], and low [≤22] subgroups), agreement analysis was repeated. There was a significant correlation between SS-MDCT and SS-ICA in the low SS group (r=0.63, P = 0.043) but no significant correlation in the high SS group (r=0.036, P = 0.677). The inter-test agreement analysis showed at least moderate agreement, whereas thrombotic lesions and the type of bifurcation lesion showed fair agreement. CONCLUSION The calculation of SS-MDCT by adapting SS-ICA parameters achieved nearly the same degree of precision as SS-ICA and was better than SS-ICA, especially in the low SS group. PMID:27328718

  19. Lens dosimetry during examination of the sella turcica: comparison between conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Louis, O.; Bette, L.; Noseda, A.

    1986-01-01

    Lens irradiation measurements were performed with thermo-luminescent lithium fluoride dosimeters during tomographic examinations of the sella turcica, simulated on a phantom head. Lens dosimetry during linear or hypocycloidal conventional tomography was compared with that during computed tomography (CT). Results showed that CT involved much lower radiation exposure to the lens than did conventional tomography and that the major part of the irradiation delivered by CT was related to axial scanning. Therefore, the major finding was that lens irradiation during CT of the sella can be kept at a particularly low level (< 1 m Gy/8 sections) when only coronal scanning is performed.

  20. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  1. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle Westergren;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...... study investigates the positive (PPV) and negative predictive value (NPV) of PET-CT in stage I disease and the clinical impact of the scan results in all disease stages....

  2. Pigmented villonodular synovitis mimics metastases on fluorine 18 fluorodeoxyglucose position emission tomography-computed tomography.

    Science.gov (United States)

    Elumogo, Comfort O; Kochenderfer, James N; Civelek, A Cahid; Bluemke, David A

    2016-04-01

    Pigmented villonodular synovitis (PVNS) is a benign joint disease best characterized on magnetic resonance imaging (MRI). The role of fluorine 18 fluorodeoxyglucose ((18)F-FDG) position emission tomography-computed tomography (PET-CT) in the diagnosis or characterization remains unclear. PVNS displays as a focal FDG avid lesion, which can masquerade as a metastatic lesion, on PET-CET. We present a case of PVNS found on surveillance imaging of a lymphoma patient.

  3. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques....... Here, a new method for optimising cardiac coronary CT with optical coherence tomography (OCT) and histopathology is presented. Materials and methods: Twenty human hearts obtained from autopsies were used. A contrast agent that solidifies after cooling was injected into the coronary arteries. CT...

  4. Multifocal sparganosis mimicking lymphoma involvement: Multimodal imaging findings of ultrasonography, CT, MRI, and position emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heo, So Young; Park, Ji Yeon; Park, Noh Hyuck; Park, Chan Sub; Kim, Tae Jung [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of); Jun, Hyun Jung [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2016-01-15

    Sparganosis is a rare parasitic disease caused by the migrating plerocercoid larva of Spirometra species tapeworms. The most frequent clinical manifestation is a subcutaneous nodule resembling a neoplasm. In this study, we presented multimodal findings of ultrasonography, computed tomography, magnetic resonance imaging, positron emission tomography-computed tomography and follow-up imagings on multifocal sparganosis, mimicking lymphoma involvement in a patient with lymphoma.

  5. First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference

    Energy Technology Data Exchange (ETDEWEB)

    Diekhoff, Torsten; Kiefer, Tobias; Hamm, Bernd; Hermann, Kay-Geert A. [Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Department of Radiology, Berlin (Germany); Ziegeler, Katharina; Feist, Eugen [Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Department of Rheumatology and Clinical Immunology, Berlin (Germany); Mews, Juergen [Toshiba Medical Systems Europe, BV, Zoetermeer (Netherlands)

    2015-11-15

    Dual-energy computed tomography (DECT) is an emerging imaging technique for examining patients with suspected gout. Single-source dual-energy CT (S-DECT) is a new way of obtaining DECT information on conventional CT scanners rather than using special dual-source CT systems. We tested the feasibility of S-DECT (320-row CT; Aquilion ONE, Toshiba Medical Systems, Otawara, Japan) in 6 patients (5 men, 1 woman; mean age 61.3, range 48 to 69 years) with acute arthralgia and suspected gout, and compared the S-DECT findings with the results of joint aspiration. Three patients had a diagnosis of gouty arthritis with negatively birefringent crystals in synovial fluid, in addition to gouty tophi in S-DECT. Three patients had no detectable crystals by polarization microscopy and no tophi on DECT. Their final diagnoses were rheumatoid arthritis, activated osteoarthritis, and septic arthritis in one case each. This initial experience suggests that S-DECT might be a valuable alternative to dual-source CT. Hence, more patients may benefit from its additional diagnostic abilities in the future. (orig.)

  6. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  7. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  8. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  9. Computed tomography of sellar and parasellar lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Mitsunori; Aoki, Hideo (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1982-06-01

    Neuroradiological modalities, particularly CT, for sellar and parasellar lesions were reviewed. Although accurate preoperative diagnosis is sometimes difficult, CT diagnosed 83% as far as pituitary adenoma, craniopharyngioma and meningioma were concerned and demonstrated abnormal findings in 95% of parasellar tumors. At the authors' department, CT visualized abnormalities in all cases, with the exception of suprasellar arachnoid cyst, but a histological diagnosis was possible only in 84%. Since lesions including tumors cannot be completely denied even if CT shows normal images, findings by modalities such as plain craniography, cerebral tomography, cerebral angiography and cisternography should be judged comprehensively.

  10. Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

    Science.gov (United States)

    Bittencourt, Márcio Sommer; Schmidt, Bernhard; Seltmann, Martin; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner Günther; Achenbach, Stephan

    2011-10-01

    Improvements in image quality in cardiac computed tomography may be achieved through iterative image reconstruction techniques. We evaluated the ability of "Iterative Reconstruction in Image Space" (IRIS) reconstruction to reduce image noise and improve subjective image quality. 55 consecutive patients undergoing coronary CT angiography to rule out coronary artery stenosis were included. A dual source CT system and standard protocols were used. Images were reconstructed using standard filtered back projection and IRIS. Image noise, attenuation within the coronary arteries, contrast, signal to noise and contrast to noise parameters as well as subjective classification of image quality (using a scale with four categories) were evaluated and compared between the two image reconstruction protocols. Subjective image quality (2.8 ± 0.4 in filtered back projection and 2.8 ± 0.4 in iterative reconstruction) and the number of "evaluable" segments per patient 14.0 ± 1.2 in filtered back projection and 14.1 ± 1.1 in iterative reconstruction) were not significant different between the two methods. However iterative reconstruction had a lower image noise (22.6 ± 4.5 HU vs. 28.6 ± 5.1 HU) and higher signal to noise and image to noise ratios in the proximal coronary arteries. IRIS reduces image noise and contrast-to-noise ratio in coronary CT angiography, thus providing potential for reducing radiation exposure.

  11. Anaesthesia for magnetic resonance imaging/computed tomography.

    Science.gov (United States)

    Funk, W; Taeger, K

    2000-08-01

    The need for general anaesthesia for magnetic resonance imaging/computed tomography investigations can be reduced by the implementation of structured sedation programmes supervised by anaesthetists. Despite its side-effects, chloral hydrate is still the drug most widely used. Rectal thiopental or intravenous propofol are suggested anaesthetic agents for pre-school children and uncooperative or claustrophobic individuals. Spiral computed tomography scans and ultrafast magnetic resonance imaging shorten immobilization times further. However, functional magnetic resonance imaging and intervention techniques in neuroradiology depend on a motionless patient. A useful strategy for testing anaesthesia equipment has been outlined.

  12. Computed tomography and magnetic resonance imaging of the pericardium.

    Science.gov (United States)

    Olson, M C; Posniak, H V; McDonald, V; Wisniewski, R; Moncada, R

    1989-07-01

    Computed tomography is an established modality for the evaluation of the pericardium. It is used to evaluate complicated pericardial effusions, pericardial thickening, calcific pericarditis, pericardial cysts, postoperative changes and primary and metastatic neoplasms of the pericardium. Magnetic resonance imaging is being used with increasing frequency in the evaluation of pericardial disease. It offers advantages over computed tomography, including a potential for tissue characterization, absence of ionizing radiation or need for intravenous contrast medium, and the ability to scan in any plane. Disadvantages include greater cost, longer examination times and the inability to identify calcification positively.

  13. Investigation of a near-infrared-ray computed tomography scanner

    Science.gov (United States)

    Sato, Eiichi; Oda, Yasuyuki; Satoi, Yuichi; Yamaguchi, Satoshi; Ishii, Tomotaka; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Watanabe, Manabu; Kusachi, Shinya

    2016-10-01

    In the near-infrared-ray computed tomography (NIR-CT) scanner, NIR rays are produced from a light-emitting diode (LED) and detected using an NIR phototransistor (PT). The wavelengths of the LED peak intensity and the PT high sensitivity in the data table are both 940 nm. The photocurrents flowing through the PTR are converted into voltages using an emitter-follower circuit, and the output voltages are sent to a personal computer through an analog-digital converter. The NIR projection curves for tomography are obtained by repeated linear scans and rotations of the object, and the scanning is conducted in both directions of its movement.

  14. Direct sagital computed tomography of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Manzione, J.V. (Harvard Medical School, Boston, MA); Seltzer, S.E.; Katzberg, R.W.; Hammerschlag, S.B.; Chiango, B.F.

    1983-01-01

    Temporomandibular joint dysfunction is a common clinical problem that has been reported to affect 4%-28% of adults. Temporomandibular joint arthrography has shown that many of these patients have intraarticular abnormalities involving the meniscus. A noninvasive test that could demonstrate the meniscus as well as bony abnormalities of the joint would be an important advance. In an attempt to develop such a noninvasive test, we have performed direct sagittal computed tomography (CT) on cadaver temporomandibular joints and have correlated the images with anatomic sections. We are currently applying this technique clinically and report one representative example in which direct sagittal computed tomography of the temporomandibular joint accurately demonstrated an anteriorly displaced meniscus.

  15. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Institute of Scientific and Technical Information of China (English)

    Ka-Kit Wong; Arpit Gandhi; Benjamin L Viglianti; Lorraine M Fig; Domenico Rubello; Milton D Gross

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches using the terms: "SPECT/CT"; "functional anatomic mapping"; "transmission emission tomography"; "parathyroid adenoma"; "thyroid cancer"; "neuroendocrine tumor"; "adrenal"; "pheochromocytoma"; "paraganglioma"; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts(case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology.RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the biodistribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTclabeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol(NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma.CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to

  16. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  17. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  18. Thoracic applications of dual-source CT technology.

    Science.gov (United States)

    Boroto, Kahimano; Remy-Jardin, Martine; Flohr, Thomas; Faivre, Jean-Baptiste; Pansini, Vittorio; Tacelli, Nunzia; Schmidt, Bernhard; Gorgos, Andrei; Remy, Jacques

    2008-12-01

    Among the various imaging modalities available, CT has remained over time the core imaging technique for the evaluation of respiratory disorders. The recent advent of dual-source CT offers innovative approaches to investigate thoracic diseases, based on the use of one or two tubes as well as single or dual energy to scan the entire thorax. Two major options can be used in clinical practice with promising results. Dual source, single-energy scanning allows scanning of the entire thorax with ultra-high temporal resolution which opens the field of integrated cardiothoracic imaging without ECG gating as well as optimized evaluation of pediatric and adult patients with limited ability to cooperate. Dual-source, dual-energy acquisitions represent another very innovative means of investigating respiratory disorders, adding tissue characterization and functional analysis to morphological evaluation. The purpose of this review article is to provide results on preliminary experiences with the above-mentioned scanning conditions with dual-source CT and to envisage potential forthcoming applications in the field of thoracic imaging.

  19. 3D artefact for concurrent scale calibration in Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    A novel artefact for calibration of the scale in 3D X-ray Computed Tomography (CT) is presented. The artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. The artefact is positioned and scanned together with the workpiece inside the CT scanner ...

  20. Computer tomography in Caisson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, F.; Csobaly, S.

    1981-07-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts.

  1. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    subject number. The principal investigator collated all data collection sheets and organized them into a spreadsheet for final analysis. Data...available cone-beam computed tomography machine . Am J 01ihod Dentofacial Orthop 2008; 134:573-82. 7. Moshfeghi M, Tavakoli MA, Hosseini ET, et al

  2. Geometrical metrology on silicone rubber by computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Pacurar, Ramona Alexandra; De Chiffre, Leonardo

    2011-01-01

    Computed tomography (CT) represents a suitable measuring technique for investigation of deformable materials, since no forces are developed on the part during scanning. As for any other measuring instruments, the traceability of the CT scanners needs to be assured. An investigation on geometrical...

  3. Traceability investigation in Computed Tomography using industry-inspired workpieces

    DEFF Research Database (Denmark)

    Kraemer, Alexandra; Stolfi, Alessandro; Schneider, Timm

    2017-01-01

    This paper concerns an investigation of the accuracy of Computed Tomography (CT) measurements using four industry-inspired workpieces. A total of 16 measurands were selected and calibrated using CMMs. CT measurements on industry-inspired workpieces were carried out using two CTs having different...

  4. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  5. Computed Tomography Features of Spontaneously Perforated Pyometra: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.S.; Tan, C.K.; Mak, C.W.; Chia, C.C.; Kuo, C.Y.; Yu, W.L. [Chi-Mei Medical Center, Tainan, Taiwan (China). Depts. of Intensive Care Medicine, Radiology, Obstetrics and Gynecology, and Surgery

    2006-03-15

    Spontaneous perforation of pyometra is an extremely rare emergent gynecologic disease. We report a 73-year-old woman with a spontaneously perforated pyometra presenting with acute abdomen in the emergency department. A dedicated computed tomography examination of the abdominal and pelvic regions revealed the diagnosis. The patient recovered well after surgical intervention and antibiotic treatment.

  6. Fractional flow reserve derived from coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Eftekhari, Ashkan; Min, James; Achenbach, Stephan

    2016-01-01

    AIMS: Fractional flow reserve (FFR) derived from coronary computed tomography (FFRCT) has high diagnostic performance in stable coronary artery disease (CAD). The diagnostic performance of FFRCT in patients with hypertension (HTN) and diabetes (DM), who are at risk of microvascular impairment, is...

  7. Computed tomography of the human developing anterior skull base

    NARCIS (Netherlands)

    J. van Loosen (J.); A.I.J. Klooswijk (A. I J); D. van Velzen (D.); C.D.A. Verwoerd (Carel)

    1990-01-01

    markdownabstractAbstract The ossification of the anterior skull base, especially the lamina cribrosa, has been studied by computed tomography and histopathology. Sixteen human fetuses, (referred to our laboratory for pathological examination after spontaneous abortion between 18 and 32 weeks of ge

  8. COMPUTED TOMOGRAPHY IN HYDATID CYST OF THE ORBIT

    Directory of Open Access Journals (Sweden)

    K. Abbassioun

    1982-07-01

    Full Text Available Two cases of hydatid cysts of the orbit causing unilateral exophthalmos are reported. Diagnosis were suspected by means of computed tomography (CT and confirmed at Operation. CT changes are described and its value in diagnosis of this lesion particularly in the endemic areas is stressed.

  9. Operator radiation exposure in cone-beam computed tomography guidance

    NARCIS (Netherlands)

    Braak, S.J.; Strijen Van, M. J L; Meijer, E.; Heesewijk Van, J. P M; Mali, W. P T M

    2016-01-01

    Objectives: Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Methods: Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile rad

  10. Use of Computed Tomography Scans for Cochlear Implants

    OpenAIRE

    Whiting, Bruce R.; Holden, Timothy A.; Brunsden, Barry S.; Finley, Charles C.; Skinner, Margaret W.

    2007-01-01

    While 3-dimensional (3D) imaging by computed tomography has long been desirable for research and treatment of cochlear-implant patients, technical challenges have limited its wide application. Recent developments in scanner hardware and image processing techniques now allow image quality improvements that make clinical applications feasible. Validation experiments were performed to characterize a new methodology and its imaging performance.

  11. Computed tomography diagnosis of partial anomalous pulmonary venous drainage.

    Science.gov (United States)

    Posniak, H V; Dudiak, C M; Olson, M C

    1993-01-01

    A case of the rarely occurring partial anomalous pulmonary venous drainage of the right upper lobe into the azygos arch is presented. Computed tomography (CT) clearly demonstrated the abnormal vessel coursing through the right upper lobe and draining into the azygos arch.

  12. Coronary computed tomography - present status and future directions

    NARCIS (Netherlands)

    Apfaltrer, P.; Schoepf, U. J.; Vliegenthart, R.; Rowe, G. W.; Spears, J. R.; Fink, C.; Nance, J. W.

    2011-01-01

    The use of coronary computed tomography angiography (cCTA) is growing rapidly, in large part because of fast-paced technical innovations that have increased diagnostic accuracy while providing new opportunities for radiation dose reduction. cCTA using recent generation CT scanners has been repeatedl

  13. Coronary artery fly-through using electron beam computed tomography

    NARCIS (Netherlands)

    van Ooijen, P M; Oudkerk, M; van Geuns, R J; Rensing, B J; de Feyter, P J

    2000-01-01

    BACKGROUND: Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. METHODS AND RESULTS:

  14. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  15. Tolerance Verification of an Industrial Assembly using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo; Regi, Francesco

    2016-01-01

    This paper reports on results of tolerance verification of a multi-material assembly by using Computed Tomography (CT). The workpiece comprises three parts which are made out of different materials. Five different measurands were inspected. The calculation of measurement uncertainties was attempt...

  16. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Jakobsen, Annika Loft; Hansen, Mads;

    2006-01-01

    In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study was to investigate the value...

  17. Global seismic tomography and modern parallel computers

    Directory of Open Access Journals (Sweden)

    A. Piersanti

    2006-06-01

    Full Text Available A fast technological progress is providing seismic tomographers with computers of rapidly increasing speed and RAM, that are not always properly taken advantage of. Large computers with both shared-memory and distributedmemory architectures have made it possible to approach the tomographic inverse problem more accurately. For example, resolution can be quantified from the resolution matrix rather than checkerboard tests; the covariance matrix can be calculated to evaluate the propagation of errors from data to model parameters; the L-curve method can be applied to determine a range of acceptable regularization schemes. We show how these exercises can be implemented efficiently on different hardware architectures.

  18. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science, Tec...

  19. Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C.H., E-mail: jchu@rush.edu

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  20. Cranial computed tomography in psychiatry. Kraniale Computertomographie in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Falkai, P. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany)); Bogerts, B. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany))

    1993-08-13

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.)

  1. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    Science.gov (United States)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  2. X-ray computed tomography of PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Pfrang, Andreas; Veyret, Damien; Tsotridis, Georgios [Commission of the European Communities, Petten (Netherlands). Joint Reseach Centre, Inst. for Energy; Janssen, Gaby [Energy Research Centre of the Netherlands ECN, Petten (Netherlands). Dept. of Hydrogen and Clean Fossil Fuels

    2010-07-01

    Proton exchange membrane (PEM) fuel cells were investigated by 3D x-ray computed tomography at a voxel size of 0.7 {mu}m. It is shown that this lab-based technique is not only suitable for the investigation of gas diffusion layers (GDL) as well as the investigation of membrane electrode assemblies (MEA), but also allows the calculation of macroscopic physical properties. The resolution of computed tomography is clearly sufficient to image the carbon fiber structure of gas diffusion layers in the as received GDLs as well as GDLs integrated into membrane electrode assemblies. It is also possible to visualize the catalyst layer within the MEA, which allows the investigation of layer thickness and structural defects on a larger scale than with conventional techniques. The macroscopic effective thermal conductivities of the gas diffusion layers were computed based on the 3D GDL structure reconstructed from tomography data to produce more reliable input data for fuel cell modeling. The computation was carried out by solving the energy equation considering a pure thermal conduction problem. The computations show - in agreement with the expectation and experimental data - that the through-plane thermal conductivities are lower than the in-plane thermal conductivities. (orig.)

  3. Coordinate Metrology by Traceable Computed Tomography

    DEFF Research Database (Denmark)

    Müller, Pavel

    metrology and coordinate metrology and is currently becoming more and more important measuring technique for dimensional measurements. This is mainly due to the fact that with CT, a complete three-dimensional model of the scanned part is in a relatively short time visualized using a computer...... is an important factor for decision making about manufactured parts. However, due to many influences in CT, estimation of the uncertainty is a challenge, also because standardized procedures and guidelines are not available yet. In this thesis, several methods for uncertainty estimation were applied in connection...

  4. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  5. Evaluation of low-dose dual energy computed tomography for in vivo assessment of renal/ureteric calculus composition.

    Science.gov (United States)

    Mahalingam, Harshavardhan; Lal, Anupam; Mandal, Arup K; Singh, Shrawan Kumar; Bhattacharyya, Shalmoli; Khandelwal, Niranjan

    2015-08-01

    This study aimed to assess the accuracy of low-dose dual-energy computed tomography (DECT) in predicting the composition of urinary calculi. A total of 52 patients with urinary calculi were scanned with a 128-slice dual-source DECT scanner by use of a low-dose protocol. Dual-energy (DE) ratio, weighted average Hounsfield unit (HU) of calculi, radiation dose, and image noise levels were recorded. Two radiologists independently rated study quality. Stone composition was assessed after extraction by Fourier transform infrared spectroscopy (FTIRS). Analysis of variance was used to determine if the differences in HU values and DE ratios between the various calculus groups were significant. Threshold cutoff values to classify the calculi into separate groups were identified by receiver operating characteristic curve analysis. A total of 137 calculi were detected. FTIRS analysis differentiated the calculi into five groups: uric acid (n=17), struvite (n=3), calcium oxalate monohydrate and dihydrate (COM-COD, n=84), calcium oxalate monohydrate (COM, n=28), and carbonate apatite (n=5). The HU value could differentiate only uric acid calculi from calcified calculi (p80% sensitivity and specificity to differentiate them. The DE ratio could not differentiate COM from COM-COD calculi. No study was rated poor in quality by either of the observers. The mean radiation dose was 1.8 mSv. Low-dose DECT accurately predicts urinary calculus composition in vivo while simultaneously reducing radiation exposure without compromising study quality.

  6. Dual energy computer tomography. Objectve dosimetry, image quality and dose efficiency; Dual Energy Computertomographie. Objektive Dosimetrie, Bildqualitaet und Dosiseffizienz

    Energy Technology Data Exchange (ETDEWEB)

    Schenzle, Jan Christian

    2012-05-24

    The aim of the present studies was an objective reflection of newly developed methods of modern imaging techniques concerning radiation exposure to the human body. Dual Source computed tomography has opened up a broad variety of new diagnostic possibilities. Using two X-ray sources with an angular offset of about 90 in a single gantry, images with a high spatiotemporal resolution can be achieved, for example in patients suffering acute chest pain. The Dual Energy Mode is based on the acquisition of two data sets with two different X-ray spectra which make it possible to identify certain substances with different spectral properties like bone, iodine or other organic material. [6-17] There is no doubt that this technical innovation will make an essential contribution to clinical diagnostics, but it remained to be proven that there is no additional dose. An anthropomorphic Phantom and thermoluminiscent detectors were used to objectively quantify the radiation dose resulting from the different examination protocols. For Dual Energy CT examinations, it was possible to verify dose neutrality in combination with comparable image quality and even improved contrast to noise ratio. Nowadays, this protocol is used in clinical routine examinations, e.g. for the evaluation of pulmonary embolism. A milestone in dose reduction was reached with modern triple rule out protocols. Causes of acute chest pain such as heart attack, pulmonary embolism or aortic rupture can be differentiated in a single examination with a high precision and a fractional amount of dose compared to conventional methods.

  7. Effect of reader experience on variability, evaluation time and accuracy of coronary plaque detection with computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saur, Stefan C.; Szekely, Gabor [ETH Zurich, Computer Vision Laboratory, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Group, Boston, MA (United States); Stolzmann, Paul; Baumueller, Stephan; Leschka, Sebastian; Scheffel, Hans; Desbiolles, Lotus [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Fuchs, Thomas J. [ETH Zurich, Department of Computer Science, Zurich (Switzerland); Cattin, Philippe C. [ETH Zurich, Computer Vision Laboratory, Zurich (Switzerland); University of Basel, Medical Image Analysis Center, Basel (Switzerland)

    2010-07-15

    To assess the effect of reader experience on variability, evaluation time and accuracy in the detection of coronary artery plaques with computed tomography coronary angiography (CTCA). Three independent, blinded readers with three different experience levels twice labelled 50 retrospectively electrocardiography (ECG)-gated contrast-enhanced dual-source CTCA data sets (15 female, age 67.3 {+-} 10.4 years, range 46-86 years) indicating the presence or absence of coronary plaques. The evaluation times for the readings were recorded. Intra- and interobserver variability expressed as {kappa} statistics and sensitivity, specificity, and negative and positive predictive values were calculated for plaque detection, with a consensus reading of the three readers taken as the standard of reference. A bootstrap method was applied in the statistical analysis to account for clustering. Significant correlations were found between reader experience and, respectively, evaluation times (r = -0.59, p < 0.05) and intraobserver variability (r = 0.73, p < 0.05). The evaluation time significantly differed among the readers (p < 0.05). The observer variability for plaque detection, compared with the consensus, varied between {kappa} = 0.582 and {kappa} = 0.802. Variability of plaque detection was significantly smaller (p < 0.05) and more accurate (p < 0.05) for the most experienced reader. Reader experience significantly correlated with observer variability, evaluation time and accuracy of coronary plaque detection at CTCA. (orig.)

  8. Computed tomography of the acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ho Young; Suh, Jin Suck; Park, Chang Yun; Lee, Kil Woo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-04-15

    In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

  9. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  10. Computed tomography of human joints and radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, E; Bernardi, R; Hollerbach, K; Logan, C; Martz, H; Roberson, G P

    1999-06-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have been increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed. (1) The computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. (2) They are developing NDE and NDE techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity.

  11. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  12. Brain computed tomography of the hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W. K.; Park, C. K.; Cho, O. K.; Hahm, C. K. [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1980-12-15

    Now a day, hypertension is more increasing in frequency and ranked the top of the causes of death in Korea and other nations. Most of cerebrovascular accidents in hypertensive patients are composed of vascular occlusive changes and hemorrhages. In cerebral angiogram, we can only detect occlusion of large artery and large mass effect from hematoma or cerebral infarction without identification of its entity. The computed tomogram, however, is the best way for evaluation of cerebrovascular diseases including detection of nature, location, amount, and associated changes. This study includes evaluation of computed tomograms of 106 patients with hypertension during the period of 17 months from Feb. 1979 to June 1980 in the department of radiology, college of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 106 patients was broad ranging from 25 years to 76 years. 67.9% of patients were over the age of 50. The male and female sex ratio was 3:2. 2. 28 out of 106 patients were normal and 78 patients revealed abnormal on C. T. findings; those were intracranial hemorrhage (35 patients), cerebral infarction (32 patients) and brain atrophy (11 patients). 3. All of the intracranial hemorrhage except one were intracerebral hemorrhage; those were located in the cerebral hemisphere (19 patients), basal ganglia (15 patients) and brain stem (1 patient). The except one case of intracranial hemorrhage was subdural hematoma. 7 patients of intraventricular hemorrhage and 1 patient of subarachnoid hemorrhage were combined with intracerebral hemorrhage. 2/3 of patients who had hemorrhage in cerebral hemisphere revealed lesions in the parietal and temporal lobes. 4. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (20 cases), and the next was basal ganglia (11 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. The left basal ganglia was more commonly involved

  13. Computed Tomography of the Normal Bovine Tarsus.

    Science.gov (United States)

    Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K

    2016-12-01

    The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20(o) C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology. © 2016 Blackwell Verlag GmbH.

  14. Role of computed tomography in pancreatic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Kim, Ki Whang; Lee, Jong Tae; Oh, Sei Jung [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1991-03-15

    At Yonsei University Hospital from January 1984 to August 1990, computed tomographic (CT) scans of 13 patients with surgically proven pancreatic injuries after blunt abdominal trauma, including 6 pancreatic lacerations or contusions, 6 pancreatic fractures, and one post-traumatic pseudocyst, were retrospectively reviewed to determine the role and accuracy of the CT in evaluating pancreatic injury. CT can document gross pancreatic injury by showing focal or diffuse enlargement (1), area of diminished attenuation (3), separation (5), focal hematoma (2), and peripancreatic change, including peripancreatic hematoma (2), fluid collection (11), perirenal fascial thickening (10), omental and mesenteric change (5), and bowel change (2). CT correctly diagnosed pancreatic fracture in 5 cases, post-raumatic pseudocyst in 1 case, and pancreatic laceration in 3 cases in 9 of these patients. There were 4 false negative diagnoses, including 3 pancreatic lacerations and 1 pancreatic fracture. A CT is of pancreatic trauma could be difficult to diagnosis in patients who are scanned within 24 hrs after an injury or to distinguish a motion or streak artifact caused by a nasogastric tube or air-oral contrast fluid level in the stomach.

  15. The HelCat dual-source plasma device.

    Science.gov (United States)

    Lynn, Alan G; Gilmore, Mark; Watts, Christopher; Herrea, Janis; Kelly, Ralph; Will, Steve; Xie, Shuangwei; Yan, Lincan; Zhang, Yue

    2009-10-01

    The HelCat (Helicon-Cathode) device has been constructed to support a broad range of basic plasma science experiments relevant to the areas of solar physics, laboratory astrophysics, plasma nonlinear dynamics, and turbulence. These research topics require a relatively large plasma source capable of operating over a broad region of parameter space with a plasma duration up to at least several milliseconds. To achieve these parameters a novel dual-source system was developed utilizing both helicon and thermionic cathode sources. Plasma parameters of n(e) approximately 0.5-50 x 10(18) m(-3) and T(e) approximately 3-12 eV allow access to a wide range of collisionalities important to the research. The HelCat device and initial characterization of plasma behavior during dual-source operation are described.

  16. An Image-Domain Contrast Material Extraction Method for Dual-Energy Computed Tomography.

    Science.gov (United States)

    Lambert, Jack W; Sun, Yuxin; Gould, Robert G; Ohliger, Michael A; Li, Zhixi; Yeh, Benjamin M

    2017-04-01

    Conventional material decomposition techniques for dual-energy computed tomography (CT) assume mass or volume conservation, where the CT number of each voxel is fully assigned to predefined materials. We present an image-domain contrast material extraction process (CMEP) method that preferentially extracts contrast-producing materials while leaving the remaining image intact. Image processing freeware (Fiji) is used to perform consecutive arithmetic operations on a dual-energy ratio map to generate masks, which are then applied to the original images to generate material-specific images. First, a low-energy image is divided by a high-energy image to generate a ratio map. The ratio map is then split into material-specific masks. Ratio intervals known to correspond to particular materials (eg, iodine, calcium) are assigned a multiplier of 1, whereas ratio values in between these intervals are assigned linear gradients from 0 to 1. The masks are then multiplied by an original CT image to produce material-specific images. The method was tested quantitatively at dual-source CT and rapid kVp-switching CT (RSCT) with phantoms using pure and mixed formulations of tungsten, calcium, and iodine. Errors were evaluated by comparing the known material concentrations with those derived from the CMEP material-specific images. Further qualitative evaluation was performed in vivo at RSCT with a rabbit model using identical CMEP parameters to the phantom. Orally administered tungsten, vascularly administered iodine, and skeletal calcium were used as the 3 contrast materials. All 5 material combinations-tungsten, iodine, and calcium, and mixtures of tungsten-calcium and iodine-calcium-showed distinct dual-energy ratios, largely independent of material concentration at both dual-source CT and RSCT. The CMEP was successful in both phantoms and in vivo. For pure contrast materials in the phantom, the maximum error between the known and CMEP-derived material concentrations was 0.9 mg

  17. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    CERN Document Server

    Suerfu, Burkhant

    2015-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  18. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA.

  19. Project of evaluation of doses in computed tomography in Poland

    Energy Technology Data Exchange (ETDEWEB)

    Slusarczyk-Kacprzyk, W.; Skrzynski, W.; Bulski, W. [Centre of Oncology, Medical Physics Dept., Warsaw (Poland)

    2006-07-01

    Project of evaluation of doses in computed tomography in Poland bases on the organization solutions implemented and evaluated at one of Polish oncological centres. In this study we analyzed doses for a group of 484 patients who underwent an examination with a G.E. HiSpeed CT scanner at the Centre of Oncology in Warsaw. Patient doses (weighted computed tomography dose index, C.T.D.I.w. and dose length product, D.L.P.) have been compared against reference values published by the Polish Ministry of Health. We found that typical patient doses do not exceed reference values. As reference dose levels are defined only for a standard-size patients, sometimes they may be exceeded for a properly done examination. Polish reference dose levels are not based on up-to-date data and should be revised. (authors)

  20. Mandibular condyle position in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Hyoung Joo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Kyung Hee Univ. School of Dentistry, Seoul (Korea, Republic of)

    2006-06-15

    To evaluate position of the mandibular condyle within articular fossa in an asymptomatic population radiographically by a cone beam computed tomography. Cone beam computed tomography of 60 temporomandibular joints was performed on 15 males and 15 females with no history of any temporomandibular disorders, or any other orthodontic or photoconductors treatments. Position of mandibular condyle within articular fossa at centric occlusion was evaluated. A statistical evaluation was done using a SPSS. In the sagittal views, mandibular condyle within articular fossa was laterally located at central section. Mandibular condyles in the right and left sides were showed asymmetric positional relationship at medial, central, and lateral sections. Mandibular condyle within articular fossa in an asymptomatic population was observed non-concentric position in the sagittal and coronal views.

  1. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    OpenAIRE

    Augusto Castelli von Atzingen; Dario Ariel Tiferes; Carlos Alberto Matsumoto; Thiago Franchi Nunes; Marcos Vinicius Alvim Soares Maia; Giuseppe D'Ippolito

    2012-01-01

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensiona...

  2. Moulding process characterization of paper bottles using computed tomography

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano

    2016-01-01

    The paper presents an approach of evaluating the moulding process for production of paper bottlesusing Computed Tomography (CT). Moulded Pulp Products (MPP) are made of a formed, dewateredand dried mixture of pulp fibers and water. Modern industrial pulp moulding is datedback to the year 1903 when...... a patent for MPP production was acquired by Martin L. Keyes1. Withan increasing demand for environmental friendly products, researchers are now focusing on investigatingadvance manufacturing process for production of MPP2....

  3. Computed tomography-based subclassification of chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Dirksen, Asger; Wille, Mathilde M W

    2016-01-01

    Computed tomography (CT) is an obvious modality for subclassification of COPD. Traditionally, the pulmonary involvement of chronic obstructive pulmonary disease (COPD) in smokers is understood as a combination of deleterious effects of smoking on small airways (chronic bronchitis and small airways...... observed in COPD are subtle. Furthermore, recent results indicate that emphysema may also be the essential pathophysiologic mechanism behind the airflow limitation of COPD. The definition of COPD excludes bronchiectasis as a symptomatic subtype of COPD, and CT findings in chronic bronchitis...

  4. Computed tomography changes following cryotherapy for hepatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, J.; Morris, D. L. [University of NSW, Sydney (Australia). Department of Surgery; Glenn, D. [St George Hospital, Kogarah, Sydney (Australia). Department of Radiology

    1997-05-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment. 11 refs., 1 tab., 9 figs.

  5. Predicting Neck Abscess with Contrast-Enhanced Computed Tomography

    OpenAIRE

    2014-01-01

    Neck abscesses are difficult to diagnose and treat. Currently, contrast-enhanced computed tomography (CECT) is the imaging modality of choice. The study aims to determine the predictive value of CECT findings in diagnosing neck abscess, causes of neck abscess and the most common neck space involved in the local population. 84 consecutive patients clinically suspected to have neck abscess who underwent CECT and surgical confirmation of pus were included. Demographic and clinical data were reco...

  6. Use of Cone Beam Computed Tomography in Endodontics

    Science.gov (United States)

    Scarfe, William C.; Levin, Martin D.; Gane, David; Farman, Allan G.

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imaging adjunct for endodontics. PMID:20379362

  7. The role of computed tomography in modern paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Maudgil, D.D.; McHugh, K. E-mail: kmchugh@gosh.nhs.uk

    2002-08-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study.

  8. Contraindications to lumbar puncture as defined by computed cranial tomography.

    OpenAIRE

    Gower, D. J.; Baker, A. L.; Bell, W O; Ball, M R

    1987-01-01

    Papilloedema is not always an adequate predictor of potential complications from lumbar puncture, and many clinicians are using computed tomography (CT) before lumbar puncture in an effort to identify more accurately the "at risk" patient. This paper identifies the following anatomical criteria defined by CT scanning that correlate with unequal pressures between intracranial compartments and predispose a patient to herniation following decompression of the spinal compartment: lateral shift of...

  9. Computed tomography angiography in the investigation of carotid stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, A.J.P.; Mendelow, A.D.; Birchall, D

    2001-07-01

    The assessment of carotid atherosclerotic disease is an essential pre-requisite for determining a patients suitability for carotid endarterectomy to prevent ischaemic stroke. Catheter angiography is regarded as the most accurate investigative tool for this purpose. However, with its finite morbidity and invasiveness, there is an increasing reliance upon non-invasive methods to accurately assess carotid disease. We present a review of the technique and applications of computed tomography angiography. Goddard, A.J. P.et al. (2001)

  10. Ureterolithiasis: classical and atypical findings on unenhanced helical computed tomography.

    Science.gov (United States)

    Vaswani, Kuldeep K; El-Dieb, Adam; Vitellas, Kenneth M; Bennett, William F; Bova, James G

    2002-03-01

    Evaluation of patients with acute flank pain using helical computed tomography (CT) is a well-accepted, rapid, and safe procedure in the emergency setting. Various primary and secondary signs are described in the literature for evaluation of these patients. Our purpose is to demonstrate both the classical findings associated with ureteral calculi on unenhanced helical CT and atypical findings and potential pitfalls. We also provide readers with a systematic approach to interpreting unenhanced helical CT scans performed for acute flank pain.

  11. Use of Cone Beam Computed Tomography in Endodontics

    OpenAIRE

    Scarfe, William C.; Martin D. Levin; David Gane; Farman, Allan G.

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imagin...

  12. Hypoplasia of the parotid gland: computed tomography sialography diagnosis.

    Science.gov (United States)

    Sun, Lisha; Sun, Zhipeng; Ma, Xuchen

    2013-10-01

    We report two unusual cases of non-syndromic hypoplasia of the parotid gland. The hypoplastic parotid gland mimicked a preauricular parotid tumor in one case and presented as an incidental image finding in the other case. Absence of the deep lobe and isthmus of the parotid parenchyma could be determined on axial computed tomography (CT) by revealing fat tissue composition of the parotid space. The underdeveloped superficial lobe of the gland was observed on three-dimensional CT sialography.

  13. Computed tomography of common congenital lesions of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Yuen, H.Y. E-mail: drhyyuen@doctors.org.uk; Ahuja, A.T.; Wong, K.T.; Yue, V.; Hasselt, A.C. van

    2003-09-01

    This pictorial review describes the application of high-resolution computed tomography to the investigation and pre-operative work-up of the common lesions of congenital hearing loss, including congenital aural dysplasia, various congenital ossicular anomalies, inner ear dysmorphology, large vestibular aqueduct syndrome, and congenital absence of cochlear nerve and labyrinthitis ossificans from previous infection. The aim is to help radiologists to provide a more accurate diagnosis of underlying aetiology and assist in surgical planning.

  14. Computed tomography of partial unilateral agenesis of the pectoralis muscles.

    Science.gov (United States)

    Demos, T C; Johnson, C; Love, L; Posniak, H

    1985-01-01

    The most common congenitally absent muscles are the pectoralis major and minor. Absence is usually incomplete. This anomaly is often one component of a syndrome associated with other hand (Poland syndrome) and thoracic anomalies. Computed tomography can identify partial absence of the pectoralis muscle and exactly define the altered anatomy. A patient with myasthenia gravis and isolated partial agenesis of the pectoralis muscle is presented.

  15. Analysis of Multilayered Printed Circuit Boards using Computed Tomography

    Science.gov (United States)

    2014-05-01

    resistors harder to identify as Carbon is lower in the periodic table than Aluminium Oxide . Sample 2: Colour Bar Appendix D.2...Aluminium Al2O3 Aluminium Oxide BGA Ball Grid Array Coronal XZ Plane COTS Commercial Off The Shelf C Carbon CT Computed Tomography DC Direct Current...encapsulated in steel housing. Red Circle: Thin film resistors harder to identify as Carbon is lower in the periodic table than Aluminium Oxide . Sample 2

  16. Soil Macropore Structure Characterized by X-Ray Computed Tomography

    Institute of Scientific and Technical Information of China (English)

    FENG Jie; ZHANG Jia-Bao; ZHU An-Ning; BI Jing-Wei

    2003-01-01

    Undisturbed soil core with many macropores and disturbed soil core with only one macropore (diameter is 10 mm) were probed by x-ray computed tomography (CT). The size, number, shape and continuity of macropores in the transverse and vertical sections of soil were characterized using CT scanning images. The probability densities of macropores in the transverse section of soil core exhibited a logarithmic Γ distribution.Results indicated that CT scanning was a promising nondestructive method for characterizing macropores in soils.

  17. Role of computed tomography in the study of vascular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C.; Bicego, E.; Bergamo, I.A. and others

    1988-01-01

    The most important indications to the use of computed tomography (CT) in the study of vascular pathology are considered. They may be divided as follows: 1) demonstration of vascular involvement by thoraco-abdominal neoplasms; 2) differential diagnosis between primary vascular and extra-vascular pathology; 3) assessment of primary arterial pathology. For each group, those pathologies are considered, for which CT plays a fundamental role.

  18. Computed tomography of the pathological temporal bone. Malformations. Otospongiosis

    Energy Technology Data Exchange (ETDEWEB)

    Azais, O.; Drouineau, J.; Vandermarcq, P.; Barret, D.; Gasquet, C.

    1988-01-01

    The authors evaluate the value of computed tomography in the investigation of malformations and otospongiosis of the ear. Although the CT scan appears to be essential in the preoperative of malformations of the ear, especially as otological examination frequently contributes little to the evaluation of the middle ear, otospongiosis seems to be a less formal indication, except in the predominantly cochlear forms of the disease.

  19. Computed tomography in patients with Ehlers-Danlos syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hagino, Hiroshi; Sugitani, Akitoshi; Eda, Isematsu; Takashima, Sachio; Takeshita, Kenzo

    1985-09-01

    Three patients with Ehlers-Danlos syndrome were reported. Unusual findings on computed tomography were seen in two of the three patients. One case showed peculiar and marked dilatation of the 4th ventricle, supracerebellar cistern and lateral ventricle. The other case presented disproportionate enlargement of the anterior horn of the lateral ventricle. These CT findings in the two patients suggest that developmental abnormalities may constitute a structural defect.

  20. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  1. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  2. Helical computed tomography in the assessment of abdominal aortic pathology

    Energy Technology Data Exchange (ETDEWEB)

    Vicaretti, M.; Young, N.; Jenkins, J.; Fletcher, J. [Westmead Hospital, Westmead, NSW (Australia)

    1997-05-01

    A pilot study was undertaken to evaluate the role of helical computed tomography in the assessment of abdominal aortic pathology. A total of 17 patients underwent intra-arterial digital subtraction angiography (IADSA) and helical computed tomography, with eight patients undergoing subsequent operative intervention. A comparison of radiological findings between IADSA and helical computed tomography (CT) was made and, where applicable, a comparison was made with operative findings. Pathology included abdominal aortic aneurysm (AAA) (n=12), thoraco abdominal aneurysm (n=2) and dissection (n=1), graft distension following AAA repair (n=1) and plaque haemorrhage in the distal aorta following percutaneous transluminal angioplasty (PTA) of the iliac artery (n=1). Planned operative management as based on pre-operative helical CT imaging findings, in particular with reference to the type of graft used (straight or bifurcated) was not changed at operation. Our findings on helical CT in regards to AAA, thoraco-abdominal aneurysm and dissection correlated well with angiography and surgery findings. (authors). 26 refs., 2 tabs., 5 figs.

  3. Efficacy of multislice computed tomography for gastroenteric and hepatic surgeries

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Ohtani; Mitsuo Tsubakimoto; Hidemi Kawajiri; Yuichi Arimoto; Koichi Ohno; Yasuhisa Fujimoto; Hiroko Oba; Kenji Adachi; Masaya Hirano; Shoichi Terakawa

    2005-01-01

    AIM: To determine the efficacy of multislice CT for gastroenteric and hepatic surgery.METHODS: Dual-phase helical computed tomography was performed in 50 of 51 patients who underwent gastroenteric and hepatic surgeries. Twenty-eight, eighteen and four patients suffering from colorectal cancer, gastric cancer,and liver cancer respectively underwent colorectal surgery (laparoscopic surgery: 6 cases), gastrectomy, and hepatectomy. Three-dimensional computed tomography imaging of the inferior mesenteric artery, celiac artery and hepatic artery was performed. And in the follow-up examination of postoperative patients, multiplanar reconstruction image was made in case of need.RESULTS: Scans in 50 patients were technically satisfactory and included in the analysis. Depiction of major visceral arteries, which were important for surgery and other treatments, could be done in all patients.Preoperative visualization of the left colic artery and sigmoidal arteries, the celiac artery and its branches, and hepatic artery was very useful to lymph node dissection,the planning of a reservoir and hepatectomy. And multiplanar reconstruction image was helpful to diagnosis for the postoperative follow-up of patients.CONCLUSION: Three-dimensional volume rendering or multiplanar reconstruction imaging performed by multislice computed tomography was very useful for gastroenteric and hepatic surgeries.

  4. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  5. SADMFR guidelines for the use of Cone-Beam Computed Tomography/ Digital Volume Tomography.

    Science.gov (United States)

    Dula, Karl; Bornstein, Michael M; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the dose to our patients by dentistry. Because of the growing concern for an uncritical and consequently rapidly increasing use of CBCT the Swiss Society of Dentomaxillofacial Radiology convened a first consensus conference in 2011 to formulate indications for CBCT, which can be used as guidelines. In this meeting, oral and maxillofacial surgery, orthodontics and temporomandibular joint disorders and diseases were treated and the most important and most experienced users of DVT in these areas were asked to participate. In general, a highly restrictive use of CBCT is required. Justifying main criterion for CBCT application is that additional, therapy-relevant information is expected that should lead to a significant benefit in patient care. All users of CBCT should have completed a structured, high-level training, just like that offered by the Swiss Society of Dentomaxillofacial Radiology.

  6. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  7. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  8. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  9. [Role of cone-beam computed tomography in diagnostic otorhinolaryngological imaging].

    Science.gov (United States)

    Perényi, Ádám; Bella, Zsolt; Baráth, Zoltán; Magyar, Péter; Nagy, Katalin; Rovó, László

    2016-01-10

    Accurate diagnosis and preoperative planning in modern otorhinolaryngology is strongly supported by imaging with enhanced visualization. Computed tomography is often used to examine structures within bone frameworks. Given the hazards of ionizing radiation, repetitive imaging studies exponentially increase the risk of damages to radiosensitive tissues. The authors compare multislice and cone-beam computed tomography and determine the role, advantages and disadvantages of cone-beam computed tomography in otorhinolaryngological imaging. They summarize the knowledge from the international literature and their individual imaging studies. They conclude that cone-beam computed tomography enables high-resolution imaging and reconstruction in any optional plane and in space with considerably lower effective radiation dose. Cone-beam computed tomography with appropriate indications proved to be an excellent diagnostic tool in otorhinolaryngological imaging. It makes an alternative to multislice computed tomography and it is an effective tool in perioperative and postoperative follow-up, especially in those cases which necessitate repetitive imaging with computed tomography.

  10. [Spiral computed tomography in the diagnosis of limb osteomyelitis].

    Science.gov (United States)

    Vasil'ev, A Iu; Bulanova, T V; Onishchenko, M P

    2003-01-01

    The results of radiation studies in 121 patients of different age (4 to 75 years) examined for limb osteomyelitis are analyzed. All the patients underwent routine X-ray study and computed tomography (CT), 26 patients had X-ray fistulography; 8, linear tomography; 10, CT fistulography; 6, scintigraphy, and 15, ultrasound study. Acute hematogenous osteomyelitis (AHO), chronic hematogenous osteomyelitis (CHO), and atypical (here Garre's sclerosing osteomyelitis and Brodie's abscess) osteomyelitis were ascertained in 10.6, 26.4, and 10.1% of cases, respectively. Posttraumatic osteomyelitis was diagnosed in almost 50% of the patients. CT defined the phase of chronic limb osteomyelitis. Spiral CT has proven to be the most effective technique for diagnosing limb osteomyelitis as compared with routine X-ray study: the accuracy of X-ray study was 81.8%, its sensitivity, 84.9%, and specificity, 60.0% and those of computed tomography were 96.7, 99.1, and 80.0%, respectively.

  11. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly.

  12. Right parietal stroke with Gerstmann's syndrome. Appearance on computed tomography, magnetic resonance imaging, and single-photon emission computed tomography.

    Science.gov (United States)

    Moore, M R; Saver, J L; Johnson, K A; Romero, J A

    1991-04-01

    We examined a patient who exhibited Gerstmann's syndrome (left-right disorientation, finger agnosia, dyscalculia, and dysgraphia) in association with a perioperative stroke in the right parietal lobe. This is the first description of the Gerstmann tetrad occurring in the setting of discrete right hemisphere pathologic findings. A well-localized vascular lesion was demonstrated by computed tomography, magnetic resonance imaging, and single-photon emission computed tomographic studies. The patient had clinical evidence of reversed functional cerebral dominance and radiologic evidence of reversed anatomic cerebral asymmetries.

  13. Evaluation of pulmonary function using single-breath-hold dual-energy computed tomography with xenon

    Science.gov (United States)

    Kyoyama, Hiroyuki; Hirata, Yusuke; Kikuchi, Satoshi; Sakai, Kosuke; Saito, Yuriko; Mikami, Shintaro; Moriyama, Gaku; Yanagita, Hisami; Watanabe, Wataru; Otani, Katharina; Honda, Norinari; Uematsu, Kazutsugu

    2017-01-01

    Abstract Xenon-enhanced dual-energy computed tomography (xenon-enhanced CT) can provide lung ventilation maps that may be useful for assessing structural and functional abnormalities of the lung. Xenon-enhanced CT has been performed using a multiple-breath-hold technique during xenon washout. We recently developed xenon-enhanced CT using a single-breath-hold technique to assess ventilation. We sought to evaluate whether xenon-enhanced CT using a single-breath-hold technique correlates with pulmonary function testing (PFT) results. Twenty-six patients, including 11 chronic obstructive pulmonary disease (COPD) patients, underwent xenon-enhanced CT and PFT. Three of the COPD patients underwent xenon-enhanced CT before and after bronchodilator treatment. Images from xenon-CT were obtained by dual-source CT during a breath-hold after a single vital-capacity inspiration of a xenon–oxygen gas mixture. Image postprocessing by 3-material decomposition generated conventional CT and xenon-enhanced images. Low-attenuation areas on xenon images matched low-attenuation areas on conventional CT in 21 cases but matched normal-attenuation areas in 5 cases. Volumes of Hounsfield unit (HU) histograms of xenon images correlated moderately and highly with vital capacity (VC) and total lung capacity (TLC), respectively (r = 0.68 and 0.85). Means and modes of histograms weakly correlated with VC (r = 0.39 and 0.38), moderately with forced expiratory volume in 1 second (FEV1) (r = 0.59 and 0.56), weakly with the ratio of FEV1 to FVC (r = 0.46 and 0.42), and moderately with the ratio of FEV1 to its predicted value (r = 0.64 and 0.60). Mode and volume of histograms increased in 2 COPD patients after the improvement of FEV1 with bronchodilators. Inhalation of xenon gas caused no adverse effects. Xenon-enhanced CT using a single-breath-hold technique depicted functional abnormalities not detectable on thin-slice CT. Mode, mean, and volume of HU histograms of xenon images

  14. ChromAIX: Fast photon-counting ASIC for Spectral Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Steadman, Roger, E-mail: roger.steadman@philips.com [Philips Research Europe, Weisshausstrasse 2, 52066 Aachen (Germany); Herrmann, Christoph; Muelhens, Oliver [Philips Research Europe, Weisshausstrasse 2, 52066 Aachen (Germany); Maeding, Dale G. [Innovative Design, under contract with Aeroflex Colorado Springs (United States)

    2011-08-21

    X-ray attenuation properties of matter (i.e. human body in medical Computed Tomography) are energy and material dependent. This dependency is largely neglected in conventional CT techniques, which require the introduction of correction algorithms in order to prevent image artefacts. The exploitation of the inherent energy information contained in the X-ray spectrum allows distinguishing the two main physical causes of energy-dependent attenuation (photo-electric effect and Compton effect). Currently a number of methods exist that allow assessing the energy-dependent attenuation in conventional systems. These methods consist of using two distinct spectra (kVp switching or dual source) or of discriminating low and high energy photons by means of stacking two detectors. Further improvements can be achieved by transitioning to direct-conversion technologies and counting-mode detection, which inherently exhibits a better signal-to-noise ratio. Further including energy discrimination enables new applications, which are not feasible with dual-energy techniques, e.g. the possibility to discriminate K-edge features (contrast agents, e.g. gadolinium) from other contributions to the X-ray attenuation of a human body. The capability of providing energy-resolved information with two or more independent measurements is referred to as Spectral CT. A new proprietary photon-counting ASIC (ChromAIX) has been developed to provide high count-rate capabilities while offering energy discrimination. ChromAIX consists of a pixel array with an isotropic pitch of 300 {mu}m. Each pixel contains independent discriminators that enable the possibility to discretize the incoming photons into a number of energy levels. Extensive electrical characterization has been carried out to assess the performance in terms of count-rate performance and noise. Observed rates exceed 10 Mcps/pixel (Poissonian, mean incoming rates >27 Mcps). The energy resolution is better than 4.1 keV FWHM and has been shown to

  15. ChromAIX: Fast photon-counting ASIC for Spectral Computed Tomography

    Science.gov (United States)

    Steadman, Roger; Herrmann, Christoph; Mülhens, Oliver; Maeding, Dale G.

    2011-08-01

    X-ray attenuation properties of matter (i.e. human body in medical Computed Tomography) are energy and material dependent. This dependency is largely neglected in conventional CT techniques, which require the introduction of correction algorithms in order to prevent image artefacts. The exploitation of the inherent energy information contained in the X-ray spectrum allows distinguishing the two main physical causes of energy-dependent attenuation (photo-electric effect and Compton effect). Currently a number of methods exist that allow assessing the energy-dependent attenuation in conventional systems. These methods consist of using two distinct spectra (kVp switching or dual source) or of discriminating low and high energy photons by means of stacking two detectors. Further improvements can be achieved by transitioning to direct-conversion technologies and counting-mode detection, which inherently exhibits a better signal-to-noise ratio. Further including energy discrimination enables new applications, which are not feasible with dual-energy techniques, e.g. the possibility to discriminate K-edge features (contrast agents, e.g. gadolinium) from other contributions to the X-ray attenuation of a human body. The capability of providing energy-resolved information with two or more independent measurements is referred to as Spectral CT.A new proprietary photon-counting ASIC (ChromAIX) has been developed to provide high count-rate capabilities while offering energy discrimination. ChromAIX consists of a pixel array with an isotropic pitch of 300 μm. Each pixel contains independent discriminators that enable the possibility to discretize the incoming photons into a number of energy levels. Extensive electrical characterization has been carried out to assess the performance in terms of count-rate performance and noise. Observed rates exceed 10 Mcps/pixel (Poissonian, mean incoming rates >27 Mcps). The energy resolution is better than 4.1 keV FWHM and has been shown to be

  16. The role of positron emission tomography/computed tomography in planning radiotherapy in endometrial cancer.

    Science.gov (United States)

    Simcock, Bryony; Narayan, Kailash; Drummond, Elizabeth; Bernshaw, David; Wells, Elizabeth; Hicks, Rodney J

    2015-05-01

    The optimal method of assessing disease distribution in endometrial cancer is widely debated. Knowledge of disease distribution assists in planning adjuvant radiotherapy; in this study we used positron emission tomography/computed tomography (PET/CT) to assess disease distribution before radiotherapy. Seventy-three consecutive patients referred to the Peter MacCallum Cancer Centre for adjuvant radiotherapy for endometrial cancer, with either high-risk disease after a hysterectomy or recurrent disease, had a PET/CT before treatment. The findings on PET/CT and clinical course were recorded. PET/CT found additional disease in 35% of postoperative patients, changing planned treatment in 31%. In the group with known recurrence, additional disease was found in 72%, changing management in 36%. PET/CT is a valuable tool for planning radiotherapy in endometrial cancer.

  17. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  18. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongmei; Zhu, Shouping, E-mail: zhusp2009@gmail.com; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin [Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education and School of Life Science and Technology, Xidian University, Xi' an, Shaanxi 710071 (China)

    2014-11-10

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

  19. Reconstruction Algorithms for Positron Emission Tomography and Single Photon Emission Computed Tomography and their Numerical Implementation

    CERN Document Server

    Fokas, A S; Marinakis, V

    2004-01-01

    The modern imaging techniques of Positron Emission Tomography and of Single Photon Emission Computed Tomography are not only two of the most important tools for studying the functional characteristics of the brain, but they now also play a vital role in several areas of clinical medicine, including neurology, oncology and cardiology. The basic mathematical problems associated with these techniques are the construction of the inverse of the Radon transform and of the inverse of the so called attenuated Radon transform respectively. We first show that, by employing mathematical techniques developed in the theory of nonlinear integrable equations, it is possible to obtain analytic formulas for these two inverse transforms. We then present algorithms for the numerical implementation of these analytic formulas, based on approximating the given data in terms of cubic splines. Several numerical tests are presented which suggest that our algorithms are capable of producing accurate reconstruction for realistic phanto...

  20. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  1. Diagnostic performance of exercise bicycle testing and single-photon emission computed tomography: Comparison with 64-slice computed tomography coronary angiography

    NARCIS (Netherlands)

    A.C. Weustink (Annick); L.A.E. Neefjes (Lisan); A. Rossi (Alexia); W.B. Meijboom (Willem Bob); K. Nieman (Koen); E. Capuano (Ermanno); H. Boersma (Eric); N.R.A. Mollet (Nico); G.P. Krestin (Gabriel); P.J. de Feyter (Pim)

    2012-01-01

    textabstractTo conduct a comparison of the diagnostic performance of exercise bicycle testing and singlephoton emission computed tomography (SPECT) with computed tomography coronary angiography (CTCA) for the detection of obstructive coronary artery disease (CAD) in patients with stable angina. 376

  2. Utility of emergency cranial computed tomography in patients without trauma.

    Science.gov (United States)

    Narayanan, Vignesh; Keniston, Angela; Albert, Richard K

    2012-09-01

    The objectives of this study were to determine, in patients admitted to the hospital from the emergency department (ED) without evidence of trauma, 1) the prevalence of clinically important abnormalities on cranial computed tomography (CCT) and 2) the frequency of emergent therapeutic interventions required because of these abnormalities. The authors retrospectively reviewed the records of all patients from 2007 between the ages of 18 and 89 years who had CCT as part of their ED evaluations prior to hospitalization. Patients with any indication of trauma were excluded, as were those who had a lumbar puncture (LP). Chief complaint, results of the ED neurologic examination, tomogram findings, and whether patients had emergent interventions were recorded. Patients presenting with altered mental status (AMS) were analyzed separately. Of the 766 patients meeting inclusion criteria, 83 (11%) had focal neurologic findings, and 61 (8%) had clinically important abnormalities on computed tomography. Emergent interventions occurred in only 12 (1.6%), 11 (92%) of whom had focal neurologic findings. In the subgroup of 287 patients with AMS as their presenting problem, 14 (4.9%) had focal findings, six (2%) had clinically important abnormalities on tomography, and only two (0.7%) required emergent interventions, both of whom had focal findings. Patients presenting with AMS were less likely to have positive findings on tomography (odds ratio [OR] = 0.16, 95% confidence interval [CI] = 0.07 to 0.39). Patients presenting with motor weakness or speech abnormalities, or who were unresponsive, were more likely to have positive findings on tomography (OR = 4.7, 95% CI = 2.6 to 8.6; OR = 4.4, 95% CI = 1.5 to 2.7; and OR = 3.3, 95% CI = 1.6 to 7.1, respectively). Of patients without evidence of trauma who receive CCT in the ED, the prevalence of focal neurologic findings and clinically important abnormalities on tomography is low, the need for emergent intervention is very low, and the

  3. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d´Amore, Francesco; Juul Mylam, Karen

    2012-01-01

    Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma......Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma...

  4. Challenges for computed tomography of overweight patients; Herausforderungen an die Computertomographie bei uebergewichtigen Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Bamberg, F.; Marcus, R.; Nikolaou, K.; Becker, C.R.; Reiser, M.F.; Johnson, T. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Petersilka, M. [Siemens AG, Computed Tomography, Forchheim, Healthcare Sector, Imaging and Therapy Division, Forchheim (Germany)

    2011-05-15

    In morbidly obese patients, computed tomography frequently represents the only viable option for non-invasive imaging diagnostics. The aim of this study was to analyze the weight limits, dose and image quality with standard CT scanners and to determine the diagnostic value and dose with a dual source XXL mode. A total of 15 patients (average body weight 189.6{+-}42 kg) were retrospectively identified who had been examined with the XXL mode. Of these patients 7 (average body weight 176.4{+-}56 kg) had been examined using both the XXL and standard protocols allowing for an intraindividual comparison in this subcollective. Additionally 14 patients weighing between 90 and 150 kg (average 106.1{+-}19 kg) examined with standard protocols were included as references. Dose, image noise and subjectively assessed image quality (rating scale 1-4) were determined. Additionally, a large abdomen phantom of 48 cm diameter was examined with both protocols at equivalent tube current-time product in order to compare the dose efficiency. The patient groups differed significantly in dose (CTDI{sub vol} XXL 72.9{+-}23 versus standard 16.7{+-}11 mGy; intraindividual 64.1{+-}20 versus 27.0{+-}15 mGy). The image noise was generally somewhat higher in the XXL group but significantly lower in the intraindividual comparison (liver 24.2{+-}14 HU versus 36.3{+-}20 HU; p=0.03; fat 15.5{+-}8 HU versus 26.2{+-}12 HU; p=0.02). With ratings of 1.9{+-}0.7 and 1.8{+-}0.7 image quality did not differ significantly in general, whereas there was a clear difference in the intraindividual comparison (1.8{+-}0.8 versus 3.0{+-}1.2) and only the XXL protocol achieved diagnostic quality in all cases, while 43% of the examinations with the standard protocol were rated as non-diagnostic. The quantification of dose efficiency in the phantom scans yielded no significant difference between the protocols. Up to 150 kg body weight, CT can be performed with the standard technique at 120 kVp with tube current

  5. The utilization of dual source CT in imaging of polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Nicolaou, S. [University of British Columbia, Vancouver General Hospital, Department of Radiology, 899 West 12th Avenue, Vancouver, British Columbia, V5Z1M9 (Canada)], E-mail: savvas.nicolaou@vch.ca; Eftekhari, A.; Sedlic, T.; Hou, D.J.; Mudri, M.J.; Aldrich, John; Louis, L. [University of British Columbia, Vancouver General Hospital, Department of Radiology, 899 West 12th Avenue, Vancouver, British Columbia, V5Z1M9 (Canada)

    2008-12-15

    Despite the growing role of imaging, trauma remains the leading cause of death in people below the age of 45 years in the western industrialized countries. Trauma has been touted as the largest epidemic in the 20th century. The advent of MDCT has been the greatest advance in trauma care in the last 25 years. However, there are still challenges in CT imaging of the polytrauma individual including time restraints, diagnostic errors, radiation dose effects and bridging the gap between anatomy and physiology. This article will analyze these challenges and provide possible solutions offered by the unique design of the dual source CT scanner.

  6. First experiences from Copenhagen with paediatric single photon emission computed tomography/computed tomography

    DEFF Research Database (Denmark)

    Mortensen, Jann; Bech, Birthe Højlund; Højgaard, Liselotte

    2011-01-01

    OBJECTIVE: This study evaluates the diagnostic value of single photon emission computed tomographic (SPECT)/multislice computed tomographic (MSCT) fusion images compared with planar scintigraphy in children. METHODS: Fifteen children [eight girls, mean age 13 years (range 2-17 years)] who were...

  7. F-18 Fluorodeoxy Glucose Positron Emission Tomography/Computed Tomography Findings in a Rare Case of Penile Leiomyosarcoma

    Directory of Open Access Journals (Sweden)

    Kuruva Manohar

    2011-01-01

    Full Text Available Penile cancer is a rare entity accounting for only 0.4% all male malignancies. Penile leiomyosarcomas are even rarer with only around 35 cases reported in literature. We report a rare case of penile leiomyosarcoma illustrating F-18 Fluorodeoxy glucose (FDG positron emission tomography/computed tomography (PET/CT features and histopathology correlation.

  8. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary...... by receiver operating characteristic analysis. The distribution of low-, intermediate-, and high-risk persons, respectively, was established and compared for each of the 3 risk models. RESULTS: Overall, all risk prediction models performed equally well. However, the Duke risk model classified the low......-risk patients more correctly than did the other models (P value of the Duke risk model was superior to the other risk models (P

  9. Precision Medicine and PET/Computed Tomography: Challenges and Implementation.

    Science.gov (United States)

    Subramaniam, Rathan M

    2017-01-01

    Precision Medicine is about selecting the right therapy for the right patient, at the right time, specific to the molecular targets expressed by disease or tumors, in the context of patient's environment and lifestyle. Some of the challenges for delivery of precision medicine in oncology include biomarkers for patient selection for enrichment-precision diagnostics, mapping out tumor heterogeneity that contributes to therapy failures, and early therapy assessment to identify resistance to therapies. PET/computed tomography offers solutions in these important areas of challenges and facilitates implementation of precision medicine. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Meirelles, Gustavo Souza Portes [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil); Irion, Klaus Loureiro [The Royal Liverpool University Hospital, Liverpool (United Kingdom); Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil); Missrie, Israel [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Sato, Juliana [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Otorrinolaringologia e Cirurgia de Cabeca e Pescoco

    2008-12-15

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  11. Value of computed tomography in patients with mucopolysaccharidosis

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, J.; Grebell, F.S.

    1987-11-01

    Cranial computed tomography (CT) was performed on 11 cases of mucopolysaccharidosis (MPS) IVA (Morquio syndrome). Our results suggest that although having normal intelligence CT changes may be seen with increasing age. In two cases white matter low density was found and in a third there was gross dilatation of the ventricles, basal cisterns and subarachnoid space. Nine other patients with various types of mucopolysaccharidosis also had cranial CT performed and in general those types associated with mental retardation showed changes although there was an interesting exception involving a case of MPS IIIA who had a normal CT scan.

  12. Computed Tomography Appearances of Various Complications Associated with Pancreatic Pseudocysts

    Energy Technology Data Exchange (ETDEWEB)

    Cheol Kim, Hyun; Mo Yang, Dal; Jung Kim, Hyoung; Ho Lee, Dong; Tae Ko, Young; Won Lim, Joo (Dept. of Radiology, East-West Neo Medical Center, Kyung-Hee Univ., Seoul (Korea))

    2008-09-15

    Most pancreatic pseudocysts are common complications of acute or chronic pancreatitis. They usually occur within the pancreas or in peripancreatic tissues, and are visualized as round or oval fluid collections with thin or thick walls on computed tomography (CT) scans. However, pancreatic pseudocysts are often combined with various complications, e.g., various organ involvements, infection, hemorrhage with pseudoaneurysm formation, rupture with fistula formation, or gastrointestinal or biliary obstruction, which may necessitate prompt intervention or surgery. This review illustrates the CT appearances of various complications associated with pancreatic pseudocysts

  13. Material reconstruction for spectral computed tomography with detector response function

    Science.gov (United States)

    Liu, Jiulong; Gao, Hao

    2016-11-01

    Different from conventional computed tomography (CT), spectral CT using energy-resolved photon-counting detectors is able to provide the unprecedented material compositions. However accurate spectral CT needs to account for the detector response function (DRF), which is often distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. The simulation results suggest that the proposed methods reconstructed more accurate material compositions than the conventional method without DRF. Moreover, the proposed linearized method with linear data fidelity from spectral resampling had improved reconstruction quality from the nonlinear method directly based on nonlinear data fidelity.

  14. Normal postperative computed tomography findings after avariety of pancreatic surgeries

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Won; Hwang, Ho Kyoung; Lee, Min Wook; Kim, Ki Whang; Kang, Chang Moo; Kim, Myeong Jin; Chung, Yong Eun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Pancreatic surgery remains the only curative treatment for pancreatic neoplasms, and plays an important role in the management of medically intractable diseases. Since the original Whipple operation in the 20th century, surgical techniques have advanced, resulting in decreased postoperative complications and better clinical outcomes. Normal postoperative imaging findings vary greatly depending on the surgical technique used. Radiologists are required to be familiar with the normal postoperative imaging findings, in order to distinguish from postoperative complications or tumor recurrence. In this study, we briefly review a variety of surgical techniques for the pancreas, and present the normal postoperative computed tomography findings.

  15. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  16. Computed tomography in the evaluation of thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-05-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum.

  17. Aortic valve area assessed with 320-detector computed tomography

    DEFF Research Database (Denmark)

    Larsen, Linnea Hornbech; Kofoed, Klaus Fuglsang; Carstensen, Helle Gervig;

    2014-01-01

    To evaluate the diagnostic accuracy of aortic valve area (AVA) assessment with 320-detector Computed Tomography (MDCT) compared to transthoracic echocardiography (TTE) in a population with mild to severe aortic valve stenosis. AVA was estimated in 169 patients by planimetry on MDCT images (AVAMDCT......) and by the continuity equation with TTE (AVATTE). To generate a reference AVA (AVAREF) we used the stroke volume from MDCT divided by the velocity time integral from CW Doppler by TTE (according to the continuity equation: stroke volume in LVOT = stroke volume passing the aortic valve). AVAREF was used as the reference...

  18. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    Science.gov (United States)

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  19. Incidental findings on cone beam computed tomography: Relate and relay

    Directory of Open Access Journals (Sweden)

    Suhas P Pande

    2015-01-01

    Full Text Available Objective: To evaluate the presence of incidental findings on cone beam computed tomography (CBCT images and to recognize their clinical importance. Materials and Methods: A total of 700 CBCT scans between January 2013 to August 2014 at Government Dental College and Hospital were evaluated retrospectively. Results: 459 incidental findings (65.57% were observed in 700 patients. Most common individual incidental finding was mucosal thickening (119 followed by pineal/habenula calcification (99 and choroid plexus (77. Conclusion: The oral and maxillofacial radiologist should carefully interpret all scans and should not ignore the incidental findings and hence avoid untoward snowballing effects.

  20. X-ray computed tomography investigations of Cucuteni ceramic statuettes

    Directory of Open Access Journals (Sweden)

    Carmen Pavel

    2013-12-01

    Full Text Available Deciphering the internal structure of prehistoric artefacts can provide spectacular insights that might help us understand the people who made them. In order to preserve the integrity of these relics of past civilisations, it is desirable to make such investigations using non-destructive techniques. Recent decades have witnessed a growth in the X-ray computed tomography (CT applications in the study of cultural heritage objects. This paper presents and discusses tomographic investigations of two Cucuteni ceramic statuettes discovered in Romania. The study was made with a CT device specially designed for archaeometric applications.

  1. Differentiation of orbital cellulitis from preseptal cellulitis by computed tomography.

    Science.gov (United States)

    Goldberg, F; Berne, A S; Oski, F A

    1978-12-01

    Computed tomography (CT) was used in the management of four patients with periorbital inflammation. These patients were selected for CT scanning because of the difficulty, on clinical examination alone, in determining the degree of orbital disease. The CT scans confirmed the presence and defined the location of an orbital abscess in three patients and eliminated the presence of an abscess in the fourth. On the basis of this experience, CT scanning is recommended in the evaluation of children with periorbital inflammation in whom proptosis, ophthalmoplegia, or loss of visual acuity develops, or in whom severe eyelid edema prevents adequate eye examination.

  2. Unusual causes of colonic wall thickening on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Turner, D.R.; Markose, G.; Arends, M.J.; Ng, C.S.; Freeman, A.H

    2003-03-01

    Computed tomography (CT) appearances in 'colitis' are often non-specific, and include mural thickening and mesenteric fat stranding. In the western world, the majority of cases will have, or be subsequently diagnosed with, inflammatory bowel disease, pseudomembranous colitis or ischaemic colitis. However, other rare conditions may also produce these rather non-specific signs. We present a number of cases demonstrating colonic wall thickening on CT due to rarer diagnoses, which are correlated with the histopathological features. Some of these CT appearances have not been described previously in the literature.

  3. Bleeding Meckel's diverticulum diagnosis: an unusual indication for computed tomography.

    Science.gov (United States)

    Danzer, D; Gervaz, P; Platon, A; Poletti, P A

    2003-01-01

    Despite the wide use of modern investigation techniques, the diagnosis of complications related to Meckel's diverticulum (MD) remains difficult. Arteriography is commonly indicated for acute bleeding, and radionuclide scans may help in identifying the site of intestinal hemorrhage. In contrast, computed tomography (CT) is usually considered little use in the diagnosis of bleeding MD. We present the case of a young patient with massive gastrointestinal hemorrhage, in whom the diagnosis of MD bleeding was preoperatively made with contrast-enhanced CT after two negatives arteriographies.

  4. Cone-beam computed tomography: A miracle for orthodontics!

    Directory of Open Access Journals (Sweden)

    Jeevan M Khatri

    2015-01-01

    Full Text Available The branch of oral medicine and radiology has always played a role of back stage worker for the branch of orthodontics and dentofacial orthopaedics. It would have been difficult for an orthodontist to gift the bright smiles to his/her patients without the 2D and 3D black and white pictures provided by the oral radiologist. Moreover, the series of advances in the various imaging modalities are playing the role of a magician for the branch of orthodontia. The present article provides valuable information about one such miracle for the field of orthodontics-cone beam computed tomography (CBCT.

  5. Computed tomography of the thymus gland in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Thorvinger, B.; Lyttkens, K.; Samuelsson, L.

    Sixteen consecutive patients with myasthenia gravis were examined by computed tomography (CT) before thymectomy. Surgical and histologic findings were compared with those obtained at CT. The results, like those of most other recent studies, indicate that CT is a reliable method for identifying thymoma. In all three patients with thymoma, and in five out of eight patients with hyperplasia, the lesion was observed at CT, giving an overall accuracy of 80%. Although tymic hyperplasia is a basically histological diagnosis an enlarged gland may give a correct diagnosis of this abnormality.

  6. The value of computed tomography in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.R.; Muhm, J.R.; Sheedy, P.F. II; Unni, K.K.; Bernatz, P.E.; Hermann, R.C. Jr.

    1983-01-01

    In a 5 year study, 19 patients with myasthenia gravis were studied by computed tomography (CT) and underwent thymectomy. CT was accurate in detecting the nine true thymic masses but could not differentiate thymomas from nonthymomatous masses, including thymic cysts. No thymoma was found in a patient under 25 years of age. In one case, the 18 sec scanner could not differentiate a large gland from a thymoma. In eight cases, glands with histologic thymic hyperplasia and histologically normal thymus appeared to be similar and could not be differentiated by CT.

  7. Urologic applications of multiplanar and three-dimensional computed tomography.

    Science.gov (United States)

    Olson, M C; Posniak, H V

    1995-01-01

    The introduction of helical computed tomography (CT) has resulted in improved quality of multiplanar reformations and three-dimensional reconstructions in the chest and abdomen and has made CT angiography a clinical reality. These imaging techniques are useful for evaluating the urinary tract, adding a new dimension to its display, resulting in improved diagnosis of renal and perirenal disease. This article reviews the indications and techniques utilized for multiplanar and three-dimensional CT for urology. The advantages and limitations are discussed, and normal and pathologic findings in the urinary tract illustrated.

  8. PRaVDA: High Energy Physics towards proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Price, T., E-mail: t.price@bham.ac.uk

    2016-07-11

    Proton radiotherapy is an increasingly popular modality for treating cancers of the head and neck, and in paediatrics. To maximise the potential of proton radiotherapy it is essential to know the distribution, and more importantly the proton stopping powers, of the body tissues between the proton beam and the tumour. A stopping power map could be measured directly, and uncertainties in the treatment vastly reduce, if the patient was imaged with protons instead of conventional x-rays. Here we outline the application of technologies developed for High Energy Physics to provide clinical-quality proton Computed Tomography, in so reducing range uncertainties and enhancing the treatment of cancer.

  9. Value of computed tomography scanning in chondromalacia patellae

    Energy Technology Data Exchange (ETDEWEB)

    Boven, F.; Bellemans, M.A.; Geurts, J.; de Boeck, H.; Potvliege, R.

    1982-06-01

    Sixtyseven patients with pain in the knee were studied. A computed tomography (CT) score indicating chondromalacia was devised, based on the results of CT after arthrography. This score takes account of the regularity, the congruity, and the imbibition of contrast material. Thus the patients could be divided into four groups: those who definitely have chondromalacia (++), probably (+), probably not (+-), and definitely not (-). These results were compared with the clinical diagnosis based on clinical signs, arthroscopy, or operation. Eighteen patients had clinically proved chondromalacia, CT scored 14++, 3+ and 1+-. Twentynine patients had no chondromalacia, CT scored 19-, 8+-, and 2+. Twenty patients had an uncertain clinical diagnosis. Arthrography was less accurate in detecting chondromalacia.

  10. Micro Computer Tomography for medical device and pharmaceutical packaging analysis.

    Science.gov (United States)

    Hindelang, Florine; Zurbach, Raphael; Roggo, Yves

    2015-04-10

    Biomedical device and medicine product manufacturing are long processes facing global competition. As technology evolves with time, the level of quality, safety and reliability increases simultaneously. Micro Computer Tomography (Micro CT) is a tool allowing a deep investigation of products: it can contribute to quality improvement. This article presents the numerous applications of Micro CT for medical device and pharmaceutical packaging analysis. The samples investigated confirmed CT suitability for verification of integrity, measurements and defect detections in a non-destructive manner. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Computed tomography in the evaluation of plexopathies and proximal neuropathies

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, J.D. (McGill Univ., Montreal, Quebec (Canada). Dept. of Neurology and Neurosurgery); Schmidt, B. (McGill Univ., Montreal, Quebec (Canada). Dept. of Radiology); Wee, R. (Montreal General Hospital, Quebec (Canada))

    1983-11-01

    The article describes nine patients with plexopathies or proximal mononeuropathies due to mass lesions. In four, computed tomography (CT) was the only radiological technique to show the cause of the neuropathy. In five patients, CT either unequivocally confirmed the presence of an abnormality or was superior to other imaging techniques in showing its full anatomical extent. CT scanning is a valuable aid in the assessment of lesions of the peripheral nervous system, particularly plexopathies and mononeuropathies caused by retroperitoneal, pelvic or superior pulmonary sulcus tumors.

  12. Angiography and computed tomography in cerebro-arterial occlusive diseases

    Energy Technology Data Exchange (ETDEWEB)

    Bradac, G.B.; Oberson, R.

    1983-01-01

    This second edition provides an exposition of occlusive diseases of the extra- and intracranial arterial circulation. The contents include: (1) pathology of the causes of cerebrovascular arterial occlusion; (2) the indications, hazards, technical aspects, and routine technique of cerebral angiography; (3) angiographic findings of the extracranial segments of the circulation to the brain; (4) computed tomography in the diagnosis of cerebrovascular diseases; (5) other investigations in the diagnosis of cerebrovascular occlusive disease; (6) conclusive considerations on the pathogenesis of transient ischemic attacks and infarctions.

  13. PET/Computed Tomography in Renal, Bladder, and Testicular Cancer.

    Science.gov (United States)

    Bouchelouche, Kirsten; Choyke, Peter L

    2015-07-01

    Imaging plays an important role in the clinical management of cancer patients. Hybrid imaging with PET/computed tomography (CT) is having a broad impact in oncology, and in recent years PET/CT is beginning to have an impact in urooncology. In both bladder and renal cancers, there is a need to study the efficacy of other tracers than F-18 fluorodeoxyglucose (FDG), particularly tracers with limited renal excretion. Thus, new tracers are being introduced. This review focuses on the clinical role of FDG and other PET agents in renal, bladder, and testicular cancers.

  14. Improved proton computed tomography by dual modality image reconstruction

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Bassler, Niels; Petersen, Jørgen B.B.;

    2014-01-01

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full...... nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully...

  15. Characterizing Green Fiber Bottle Prototypes Using Computed Tomography

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano; Stolfi, Alessandro

    2017-01-01

    in the desired shape and structure. However, there are certain limitations associated to the product characterization using tactile measuring methods. In this work, a new approach has been applied for defect analysis and quality control of non-homogenous prototype paper products using computed tomography.......Due to ever increasing demand of sustainability and biodegradability, there arises a need to develop environmental friendly packaging products. Green fiber bottle is a packaging product for carbonated beverages, made out of cellulose fibers. The production process accounts for moulding paper pulp...

  16. Benign breast lesions detected by positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Benveniste, Ana P., E-mail: apbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Yang, Wei, E-mail: wyang@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mawlawi, Osama R., E-mail: omawlawi@mdanderson.org [Department of imaging physics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Marom, Edith M., E-mail: emarom@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    {sup 18}F-fluorodeoxyglucose positron emission computed tomography (FDG PET-CT) is widely used in the initial staging and response evaluation of patients with malignancy. This review describes a spectrum of benign breast findings incidentally detected by FDG PET-CT at staging that may be misinterpreted as malignancy. We describe the pattern of distribution and intensity of FDG uptake in a spectrum of benign breast diseases with their corresponding typical morphological imaging characteristics to help the nuclear medicine physician and/or general radiologist identify benign lesions, avoiding unnecessary breast imaging work-up and biopsies.

  17. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... standard limits the reliability of accuracy calculations. RESULTS: FDG-PET would have upstaged 19% of patients and downstaged 5% of patients, leading to a different treatment in 9% of patients. For FDG-PET/CT, the corresponding figures are 17%, 5%, and 7%. In nodal regions, the sensitivity of FDG...

  18. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.

    Science.gov (United States)

    Hell, Michaela M; Bittner, Daniel; Schuhbaeck, Annika; Muschiol, Gerd; Brand, Michael; Lell, Michael; Uder, Michael; Achenbach, Stephan; Marwan, Mohamed

    2014-01-01

    Low tube voltage reduces radiation exposure in coronary CT angiography (CTA). Using 70 kVp tube potential has so far not been possible because CT systems were unable to provide sufficiently high tube current with low voltage. We evaluated feasibility, image quality (IQ), and radiation dose of coronary CTA using a third-generation dual-source CT system capable of producing 450 mAs tube current at 70 kVp tube voltage. Coronary CTA was performed in 26 consecutive patients with suspected coronary artery disease, selected for body weight Image noise was lower in IR vs FBP (60 ± 10 HU vs 74 ± 8 HU; P < .001). In patients <100 kg and with a regular heart rate <60 beats/min, third-generation dual-source CT using high-pitch spiral acquisition and 70 kVp tube voltage is feasible and provides both robust IQ and very low radiation exposure. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  19. Temporomandibular joint computed tomography: development of a direct sagittal technique

    Energy Technology Data Exchange (ETDEWEB)

    van der Kuijl, B.; Vencken, L.M.; de Bont, L.G.; Boering, G. (Univ. of Groningen, (Netherlands))

    1990-12-01

    Radiology plays an important role in the diagnosis of temporomandibular disorders. Different techniques are used with computed tomography offering simultaneous imaging of bone and soft tissues. It is therefore suited for visualization of the articular disk and may be used in patients with suspected internal derangements and other disorders of the temporomandibular joint. Previous research suggests advantages to direct sagittal scanning, which requires special positioning of the patient and a sophisticated scanning technique. This study describes the development of a new technique of direct sagittal computed tomographic imaging of the temporomandibular joint using a specially designed patient table and internal light visor positioning. No structures other than the patient's head are involved in the imaging process, and misleading artifacts from the arm or the shoulder are eliminated. The use of the scanogram allows precise correction of the condylar axis and selection of exact slice level.

  20. Computed tomography of the craniocervical junction in rheumatoid arthritis.

    Science.gov (United States)

    Castor, W R; Miller, J D; Russell, A S; Chiu, P L; Grace, M; Hanson, J

    1983-02-01

    Thirty-three patients with rheumatoid arthritis had computed tomographic examination of the craniocervical junction. This demonstrated soft tissue features which have not previously been described in published reports. A low attenuation lesion between the odontoid and the transverse ligament shown in 11 patients was considered a premonitory sign of rupture of the transverse ligament or a manifestation of active disease. Computed tomography revealed spinal cord compression in 3 patients and ligamentous changes in the transverse ligament and the alar and spinal ligaments in 26 patients. Erosion of the odontoid was shown in 19 patients and subluxation in 20 patients. No relationship could be found between the clinical signs and symptoms and the radiological abnormalities except in the case of cord compression.

  1. Denoising Message Passing for X-ray Computed Tomography Reconstruction

    CERN Document Server

    Perelli, Alessandro; Can, Ali; Davies, Mike E

    2016-01-01

    X-ray Computed Tomography (CT) reconstruction from sparse number of views is becoming a powerful way to reduce either the radiation dose or the acquisition time in CT systems but still requires a huge computational time. This paper introduces an approximate Bayesian inference framework for CT reconstruction based on a family of denoising approximate message passing (DCT-AMP) algorithms able to improve both the convergence speed and the reconstruction quality. Approximate Message Passing for Compressed Sensing has been extensively analysed for random linear measurements but there are still not clear solutions on how AMP should be modified and how it performs with real world problems. In particular to overcome the convergence issues of DCT-AMP with structured measurement matrices, we propose a disjoint preconditioned version of the algorithm tailored for both the geometric system model and the noise model. In addition the Bayesian DCT-AMP formulation allows to measure how the current estimate is close to the pr...

  2. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  3. Limited-data computed tomography algorithms for the physical sciences.

    Science.gov (United States)

    Verhoeven, D

    1993-07-10

    Five limited-data computed tomography algorithms are compared. The algorithms used are adapted versions of the algebraic reconstruction technique, the multiplicative algebraic reconstruction technique, the Gerchberg-Papoulis algorithm, a spectral extrapolation algorithm descended from that of Harris [J. Opt. Soc. Am. 54, 931-936 (1964)], and an algorithm based on the singular value decomposition technique. These algorithms were used to reconstruct phantom data with realistic levels of noise from a number of different imaging geometries. The phantoms, the imaging geometries, and the noise were chosen to simulate the conditions encountered in typical computed tomography applications in the physical sciences, and the implementations of the algorithms were optimized for these applications. The multiplicative algebraic reconstruction technique algorithm gave the best results overall; the algebraic reconstruction technique gave the best results for very smooth objects or very noisy (20-dB signal-to-noise ratio) data. My implementations of both of these algorithms incorporate apriori knowledge of the sign of the object, its extent, and its smoothness. The smoothness of the reconstruction is enforced through the use of an appropriate object model (by use of cubic B-spline basis functions and a number of object coefficients appropriate to the object being reconstructed). The average reconstruction error was 1.7% of the maximum phantom value with the multiplicative algebraic reconstruction technique of a phantom with moderate-to-steep gradients by use of data from five viewing angles with a 30-dB signal-to-noise ratio.

  4. Computed tomography of intra - and extramural ethmoid cells: iconographic essay

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Fabricio Guimaraes [McGill University Health Centre (MUHC), Montreal, QC (Canada). Montreal General Hospital; Jovem, Cassio Lemos [Med Imagem, Teresina, PI (Brazil); Moura, Leonardo de Oliveira [Centro de Treinamento em Imagenologia (CETRIM), Joao Pessoa, PB (Brazil)

    2011-09-15

    The development of the paranasal sinuses is an intricate process that begins in the intrauterine life and terminates in early adulthood. Among the paranasal sinuses, the ethmoid cells or labyrinth are probably the most complex structures, being associated with the highest number of normal variants. Variations in the pattern of pneumatization of the ethmoid cells can be divided into intra - and extramural cells. Intramural cells are those which develop within the ethmoid labyrinth. Extramural cells are those that develop isolatedly. Computed tomography is the most useful tool in the evaluation of inflammatory processes of the paranasal sinuses. Computed tomography also plays a relevant role in the preoperative planning as well as in the postoperative follow-up, since it demonstrates exact anatomical details of normal structures with accuracy in the detection of variants. In the present pictorial essay, the authors describe the most common anatomical variants of the ethmoid labyrinth and their relationship with adjacent structures. Endoscopic sinonasal surgery has become increasingly less invasive, requiring more detailed anatomical imaging of this region. (author)

  5. Incidental cardiac findings on computed tomography imaging of the thorax

    Directory of Open Access Journals (Sweden)

    El-Gendi Hossam

    2010-12-01

    Full Text Available Abstract Background Investigation of pulmonary pathology with computed tomography also allows visualisation of the heart and major vessels. We sought to explore whether clinically relevant cardiac pathology could be identified on computed tomography pulmonary angiograms (CTPA requested for the exclusion of pulmonary embolism (PE. 100 consecutive CT contrast-enhanced pulmonary angiograms carried out for exclusion of PE at a single centre were assessed retrospectively by two cardiologists. Findings Evidence of PE was reported in 5% of scans. Incidental cardiac findings included: aortic wall calcification (54%, coronary calcification (46%, cardiomegaly (41%, atrial dilatation (18%, mitral annulus calcification (15%, right ventricular dilatation (11%, aortic dilatation (8% and right ventricular thrombus (1%. Apart from 3 (3% reports describing cardiomegaly, no other cardiac findings were described in radiologists' reports. Other reported pulmonary abnormalities included: lung nodules (14%, lobar collapse/consolidation (8%, pleural effusion (2%, lobar collapse/consolidation (8%, emphysema (6% and pleural calcification (4%. Conclusions CTPAs requested for the exclusion of PE have a high yield of cardiac abnormalities. Although these abnormalities may not have implications for acute clinical management, they may, nevertheless, be important in long-term care.

  6. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  7. Estimation of feline renal volume using computed tomography and ultrasound.

    Science.gov (United States)

    Tyson, Reid; Logsdon, Stacy A; Werre, Stephen R; Daniel, Gregory B

    2013-01-01

    Renal volume estimation is an important parameter for clinical evaluation of kidneys and research applications. A time efficient, repeatable, and accurate method for volume estimation is required. The purpose of this study was to describe the accuracy of ultrasound and computed tomography (CT) for estimating feline renal volume. Standardized ultrasound and CT scans were acquired for kidneys of 12 cadaver cats, in situ. Ultrasound and CT multiplanar reconstructions were used to record renal length measurements that were then used to calculate volume using the prolate ellipsoid formula for volume estimation. In addition, CT studies were reconstructed at 1 mm, 5 mm, and 1 cm, and transferred to a workstation where the renal volume was calculated using the voxel count method (hand drawn regions of interest). The reference standard kidney volume was then determined ex vivo using water displacement with the Archimedes' principle. Ultrasound measurement of renal length accounted for approximately 87% of the variability in renal volume for the study population. The prolate ellipsoid formula exhibited proportional bias and underestimated renal volume by a median of 18.9%. Computed tomography volume estimates using the voxel count method with hand-traced regions of interest provided the most accurate results, with increasing accuracy for smaller voxel sizes in grossly normal kidneys (-10.1 to 0.6%). Findings from this study supported the use of CT and the voxel count method for estimating feline renal volume in future clinical and research studies.

  8. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  9. Proton Computed Tomography: iterative image reconstruction and dose evaluation

    Science.gov (United States)

    Civinini, C.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Lo Presti, D.; Maccioni, G.; Pallotta, S.; Randazzo, N.; Scaringella, M.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.; Bruzzi, M.

    2017-01-01

    Proton Computed Tomography (pCT) is a medical imaging method with a potential for increasing accuracy of treatment planning and patient positioning in hadron therapy. A pCT system based on a Silicon microstrip tracker and a YAG:Ce crystal calorimeter has been developed within the INFN Prima-RDH collaboration. The prototype has been tested with a 175 MeV proton beam at The Svedberg Laboratory (Uppsala, Sweden) with the aim to reconstruct and characterize a tomographic image. Algebraic iterative reconstruction methods (ART), together with the most likely path formalism, have been used to obtain tomographies of an inhomogeneous phantom to eventually extract density and spatial resolutions. These results will be presented and discussed together with an estimation of the average dose delivered to the phantom and the dependence of the image quality on the dose. Due to the heavy computation load required by the algebraic algorithms the reconstruction programs have been implemented to fully exploit the high calculation parallelism of Graphics Processing Units. An extended field of view pCT system is in an advanced construction stage. This apparatus will be able to reconstruct objects of the size of a human head making possible to characterize this pCT approach in a pre-clinical environment.

  10. Quantitative analysis of cholesteatoma using high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Shigeru; Yamasoba, Tatsuya (Kameda General Hospital, Chiba (Japan)); Iinuma, Toshitaka

    1992-05-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author).

  11. Glandular dose in breast computed tomography with synchrotron radiation.

    Science.gov (United States)

    Mettivier, G; Fedon, C; Di Lillo, F; Longo, R; Sarno, A; Tromba, G; Russo, P

    2016-01-21

    The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation from a synchrotron radiation source in the energetic range from 8 to 50 keV with 1 keV intervals, to evaluate the MGD. The code was validated with literature data, in terms of mammographic normalized glandular dose coefficients (DgN) and with ad hoc experimental data, in terms of computed tomography dose index (CTDI). Simulated cylindrical phantoms of different sizes (diameter at phantom base 8, 10, 12, 14 or 16 cm, axial length 1.5 times the radius) and glandular fraction by weight (0%, 14.3%, 25%, 50%, 75% and 100%) were implemented into the code. The validation of the code shows an excellent agreement both with previously published work and in terms of DgN and CDTI measurements. The implemented simulations show a dependence of the glandular dose estimate on the vertical dimension of the irradiated zone when a partial organ irradiation was implemented. Specific normalized coefficients for calculating the MGD to the whole breast or to the single irradiated slice were reported.

  12. Computed tomography findings of early abdominal postoperative complications

    Energy Technology Data Exchange (ETDEWEB)

    Zissin, R.; Osadchy, A. [Sapir Medical Center, Dept. of Diagnostic Imaging, Kfar Saba (Israel)]. E-mail: zisinrivka@clalit.org.il; Gayer, G. [Assaf Harofe Medical Center, Dept. of Diagnostic Imaging, Zrifin (Israel)

    2007-06-15

    Various surgical approaches are used for different abdominal pathological conditions. Postoperative complications occur not infrequently and vary according to the type of the surgery and the clinical context. Nowadays, multidetector computed tomography (MDCT) provides superb anatomic detail and diagnostic accuracy for various intraabdominal pathological processes, even if clinically unsuspected, and it thus has become an essential diagnostic tool for evaluating postoperative insults. Other advantages of abdominal MDCT include its accessibility and its speed, which allow scanning of uncooperative, marginally stable patients. Computed tomography (CT)-guided percutaneous (PC) drainage of postoperative collections is another advantage of CT. Therefore, although CT requires transportation of a critically ill, postoperative patient, it is recommended in any suspicious clinical setting because several conditions require prompt management and a correct diagnosis is crucial. In assessing a patient for suspected postoperative complications, several points should be taken into consideration, including the relevant clinical and laboratory data, the surgical findings, the type of the surgery, the time elapsed since surgery, and the operative technique (either open laparotomy of laparoscopic procedure). (author)

  13. Computed tomography angiography in patients with active gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Fatima Regina Silva; D' Ippolito, Giuseppe, E-mail: fatima.rsreis@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Cardia, P.P. [Hospital Vera Cruz, Campinas, SP (Brazil)

    2015-11-15

    Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding. (author)

  14. Breast ultrasound computed tomography using waveform inversion with source encoding

    Science.gov (United States)

    Wang, Kun; Matthews, Thomas; Anis, Fatima; Li, Cuiping; Duric, Neb; Anastasio, Mark A.

    2015-03-01

    Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the speed-of-sound distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Computer-simulation studies are conducted to demonstrate the use of the WISE method. Using a single graphics processing unit card, each iteration can be completed within 25 seconds for a 128 × 128 mm2 reconstruction region. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.

  15. Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

    Science.gov (United States)

    Rana, Nivedita; Rawat, Dinesh; Parmar, Madan; Dhawan, Devinder Kumar; Bhati, Ashok Kumar; Mittal, Bhagwant Rai

    2015-01-01

    This study was undertaken to evaluate the effect of external metal filters on the image quality of computed tomography (CT) and single photon emission computed tomography (SPECT)/CT images. Images of Jaszack phantom filled with water and containing iodine contrast filled syringes were acquired using CT (120 kV, 2.5 mA) component of SPECT/CT system, ensuring fixation of filter on X-ray collimator. Different thickness of filters of Al and Cu (1 mm, 2 mm, 3 mm, and 4 mm) and filter combinations Cu 1 mm, Cu 2 mm, Cu 3 mm each in combination with Al (1 mm, 2 mm, 3 mm, and 4 mm), respectively, were used. All image sets were visually analyzed for streak artifacts and contrast to noise ratio (CNR) was derived. Similar acquisition was done using Philips CT quality control (QC) phantom and CNR were calculated for its lexan, perspex, and teflon inserts. Attenuation corrected SPECT/CT images of Jaszack phantom filled with 444-555 MBq (12-15 mCi) of (99m)Tc were obtained by applying attenuation correction map generated by hardened X-ray beam for different filter combination, on SPECT data. Uniformity, root mean square (rms) and contrast were calculated in all image sets. Less streak artifacts at iodine water interface were observed in images acquired using external filters as compared to those without a filter. CNR for syringes, spheres, and inserts of Philips CT QC phantom was almost similar to Al 2 mm, Al 3 mm, and without the use of filters. CNR decreased with increasing copper thickness and other filter combinations. Uniformity and rms were lower, and value of contrast was higher for SPECT/CT images when CT was acquired with Al 2 mm and 3 mm filter than for images acquired without a filter. The study suggests that for Infinia Hawkeye 4, SPECT/CT system, Al 2 mm, and 3 mm are the optimum filters for improving image quality of SPECT/CT images of Jaszack or Philips CT QC phantom keeping other parameters of CT constant.

  16. Blunt trauma of bone structures of the chest: Computed tomography vs multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Petrović Kosta

    2013-01-01

    Full Text Available Background/Aim. Computerized tomography (CT, especially multidetector CT (MDCT, has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR. Methods. This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists independently and separately described the findings for 5-mmthick axial CT slices (5 mm CT as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thinslice examination together which was ultimately considered as a real, true finding. Results. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05. Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05 in favor of better display of injury by MDCT examination. Conclusion. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  17. Massively parallel computers for 3D single-photon-emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Butler, C.S.; Miller, M.I. (Washington Univ., St. Louis, MO (United States). Electronic Systems and Signals Research Lab.); Miller, T.R.; Wallis, J.W. (Washington Univ., St. Louis, MO (United States). Edward Mallinckrodt Inst. of Radiology)

    1994-03-01

    Since the introduction of the expectation-maximization (EM) algorithm for generating maximum-likelihood (ML) and maximum a posteriori (MAP) estimates in emission tomography, there have been many investigators applying the ML method. However, almost all of the previous work has been restricted to two-dimensional (2D) reconstructions. The major focus and contribution of this paper is to demonstrate a fully three-dimensional (3D) implementation of the MAP method for single-photon-emission computed tomography (SPECT). The 3D reconstruction exhibits an improvement in resolution when compared to the generation of the series of separate 2D slice reconstructions. (Author).

  18. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  19. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  20. Low Utility of Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography for Detecting Hepatocellular Carcinoma in Patients Before Liver Transplantation.

    Science.gov (United States)

    Alotaibi, Faisal; Kabbani, Monther; Abaalkhail, Faisal; Chorley, Alicia; Elbeshbeshy, Hany; Al-Hamoudi, Waleed; Alabbad, Saleh; Boehnert, Markus U; Alsofayan, Mohammad; Al-Kattan, Wael; Ahmed, Baderaldeen; Broering, Dieter; Al Sebayel, Mohamed; Elsiesy, Hussien

    2017-02-01

    Our program routinely used fluorodeoxyglucose-positron emission tomography/computed tomography as part of the liver transplant evaluation of patients with hepatocellular carcinoma. The aim of this study was to evaluate the role of this imaging modality in the pretransplant work-up. This was a retrospective chart review of our liver transplant database from January 2011 to December 2014 for all patients with hepatocellular carcinoma who underwent a liver transplant. Collected data included age, sex, cause of liver disease, imaging modality, fluorodeoxyglucose-positron emission tomography/computed tomography results, explant tissue analysis, type of transplant, and transplant outcome. During the study period, 275 liver transplants were performed. Fifty-three patients had hepatocellular carcinoma; 41 underwent fluorodeoxyglucose-positron emission tomography/computed tomography. Twenty-nine patients underwent living-donor liver transplant, and 12 patients underwent deceased-donor liver transplant. One of the 41 patients with negative FDG-imaging results had no evidence of hepatocellular carcinoma in the explant and was excluded from the study. The patients' average age was 58 years (range, 22-72 y), and 28 patients were men. The cause of liver disease was hepatitis C virus in 24 patients, cryptogenic cirrhosis in 12 patients, and hepatitis B virus in 5 patients. One patient had no hepatocellular carcinoma on explants and was excluded from the study. Twenty-five patients had hepatocellular carcinoma that met the Milan criteria, 7 were within the UCSF (University of California, San Francisco) criteria, and 8 exceeded the UCSF criteria. Of the 40 patients, 11 had positive fluorodeoxyglucose-positron emission tomography/computed tomography results (27.5%) with evidence of hepatocellular carcinoma in the explant; the remaining 29 patients (72.5%) had negative results. The fluorodeoxyglucose-positron emission tomography/computed tomography results were positive in 16% (4 of

  1. Simulation of emission tomography using grid middleware for distributed computing.

    Science.gov (United States)

    Thomason, M G; Longton, R F; Gregor, J; Smith, G T; Hutson, R K

    2004-09-01

    SimSET is Monte Carlo simulation software for emission tomography. This paper describes a simple but effective scheme for parallel execution of SimSET using NetSolve, a client-server system for distributed computation. NetSolve (version 1.4.1) is "grid middleware" which enables a user (the client) to run specific computations remotely and simultaneously on a grid of networked computers (the servers). Since the servers do not have to be identical machines, computation may take place in a heterogeneous environment. To take advantage of diversity in machines and their workloads, a client-side scheduler was implemented for the Monte Carlo simulation. The scheduler partitions the total decay events by taking into account the inherent compute-speeds and recent average workloads, i.e., the scheduler assigns more decay events to processors expected to give faster service and fewer decay events to those expected to give slower service. When compute-speeds and sustained workloads are taken into account, the speed-up is essentially linear in the number of equivalent "maximum-service" processors. One modification in the SimSET code (version 2.6.2.3) was made to ensure that the total number of decay events specified by the user is maintained in the distributed simulation. No other modifications in the standard SimSET code were made. Each processor runs complete SimSET code for its assignment of decay events, independently of others running simultaneously. Empirical results are reported for simulation of a clinical-quality lung perfusion study.

  2. Computed tomography image reconstruction from only two projections

    CERN Document Server

    Mohammad-Djafari, Ali

    2007-01-01

    English: This paper concerns the image reconstruction from a few projections in Computed Tomography (CT). The main objective of this paper is to show that the problem is so ill posed that no classical method, such as analytical methods based on inverse Radon transform, nor the algebraic methods such as Least squares (LS) or regularization theory can give satisfactory result. As an example, we consider in detail the case of image reconstruction from two horizontal and vertical projections. We then show how a particular composite Markov modeling and the Bayesian estimation framework can possibly propose satisfactory solutions to the problem. For demonstration and educational purpose a set of Matlab programs are given for a live presentation of the results. ----- French: Ce travail, \\`a but p\\'edagogique, pr\\'esente le probl\\`eme inverse de la reconstruction d'image en tomographie X lorsque le nombre des projections est tr\\`es limit\\'e. voir le texte en Anglais et en Fran\\c{c}ais.

  3. Quantifying the debonding of inclusions through tomography and computational homology.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang; Johnson, George C. (University of California, Berkeley, Berkeley, CA); Mota, Alejandro; Foulk, James W., III; Jin, Huiqing

    2010-09-01

    This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

  4. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  5. Virtual positron emission tomography/computed tomography-bronchoscopy: possibilities, advantages and limitations of clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Seemann, Marcus D. [University of Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Schaefer, Juergen F. [Eberhard-Karls University, Department of Diagnostic Radiology, Tuebingen (Germany); Englmeier, Karl-Hans [Institute of Medical Informatics, GSF-National Research Center for Environment and Health, Neuherberg (Germany)

    2007-03-15

    The aim of this study was to demonstrate the possibilities, advantages and limitations of virtual bronchoscopy using data sets from positron emission tomography (PET) and computed tomography (CT). Twelve consecutive patients with lung cancer underwent PET/CT. PET was performed with F-18-labelled 2-[fluorine-18]-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG). The tracheobronchial system was segmented with a volume-growing algorithm, using the CT data sets, and visualized with a shaded-surface rendering method. The primary tumours and the lymph node metastases were segmented for virtual CT-bronchoscopy using the CT data set and for virtual PET/CT-bronchoscopy using the PET/CT data set. Virtual CT-bronchoscopy using the low-dose or diagnostic CT facilitates the detection of anatomical/morphological structure changes of the tracheobronchial system. Virtual PET/CT-bronchoscopy was superior to virtual CT-bronchoscopy in the detection of lymph node metastases (P=0.001), because it uses the CT information and the molecular/metabolic information from PET. Virtual PET/CT-bronchoscopy with a transparent colour-coded shaded-surface rendering model is expected to improve the diagnostic accuracy of identification and characterization of malignancies, assessment of tumour staging, differentiation of viable tumour tissue from atelectases and scars, verification of infections, evaluation of therapeutic response and detection of an early stage of recurrence that is not detectable or is misjudged in comparison with virtual CT-bronchoscopy. (orig.)

  6. Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution

    Directory of Open Access Journals (Sweden)

    Frank P. DiFilippo

    2012-05-01

    Full Text Available Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT, an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling were investigated. National Electrical Manufacturers Association (NEMA NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.

  7. Positron emission tomography/computer tomography in guidance of extrahepatic hepatocellular carcinoma metastasis management

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further improve the prognosis of HCC. Most recurrences are intrahepatic. However, 30% of the recurrences are extrahepatic. The role of resection in intrahepatic recurrences is widely accepted. The role of resection in extrahepatic HCC recurrence and metastasis is not well established. 18F fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) is useful in detecting distant metastasis from a variety of malignancies and shows superior accuracy to conventional imaging modalities in identification of intrahepatic and extrahepatic metastasis. We present one patient with one new isolated omental lymph node metastasis, who had a history of huge HCC resected six years ago. The metastatic focus was identified with 18 F-FDG PET/CT and resected. The follow-up revealed good prognosis with a long-term survival potential after resection of the omental lymphatic metastasis.

  8. Cone beam computed tomography: A boon for maxillofacial imaging

    Directory of Open Access Journals (Sweden)

    Sreenivas Rao Ghali

    2017-01-01

    Full Text Available In day to day practice, the radiographic techniques used individually or in combination suffer from some inherent limits of all planar two-dimensional (2D projections such as magnification, distortion, superimposition, and misrepresentation of anatomic structures. The introduction of cone-beam computed tomography (CBCT, specifically dedicated to imaging the maxillofacial region, heralds a major shift from 2D to three-dimensional (3D approach. It provides a complete 3D view of the maxilla, mandible, teeth, and supporting structures with relatively high resolution allowing a more accurate diagnosis, treatment planning and monitoring, and analysis of outcomes than conventional 2D images, along with low radiation exposure to the patient. CBCT has opened up new vistas for the use of 3D imaging as a diagnostic and treatment planning tool in dentistry. This paper provides an overview of the imaging principles, underlying technology, dental applications, and in particular focuses on the emerging role of CBCT in dentistry.

  9. Lung cancer screening: Computed tomography or chest radiographs?

    Institute of Scientific and Technical Information of China (English)

    Edwin; JR; van; Beek; Saeed; Mirsadraee; John; T; Murchison

    2015-01-01

    Worldwide, lung cancer is the leading cause of mortalitydue to malignancy. The vast majority of cases of lung cancer are smoking related and the most effective way of reducing lung cancer incidence and mortality is by smoking cessation. In the Western world, smoking cessation policies have met with limited success. The other major means of reducing lung cancer deaths is to diagnose cases at an earlier more treatable stage employing screening programmes using chest radiographs or low dose computed tomography. In many countries smoking is still on the increase, and the sheer scale of the problem limits the affordability of such screening programmes. This short review article will evaluate the current evidence and potential areas of research which may benefit policy making across the world.

  10. Survey of patient dose in computed tomography in Syria 2009.

    Science.gov (United States)

    Kharita, M H; Khazzam, S

    2010-09-01

    The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the International Atomic Energy Agency in different regions of the world covering Asia, Africa and Eastern Europe. The dose quantities covered are CT dose index (CTDI(w)), dose-length product (DLP), effective dose (E) and collective dose. It was found that most CTDI(w) and DLP values were similar to the European reference levels and in line with the results of similar surveys in the world. The results were in good agreement with the UNSCEAR Report 2007. This study concluded a recommendation for national diagnostic reference level for the most common CT protocols in Syria. The results can be used as a base for future optimisation studies in the country.

  11. Micro-computed tomography for small animal imaging: Technological details

    Institute of Scientific and Technical Information of China (English)

    Hao Li; Hui Zhang; Zhiwei Tang; Guangshu Hu

    2008-01-01

    The high-resolution micro-computed tomography(micro-CT)system has now become an important tool for biological research.The micro-CT system enables a non-invasive inspection to screen anatomical changes in small animals.The promising advantages include high-spatial resolution,high sensitivity to bone and lung,short scan time and cost-effectiveness.The dose received by the small animal might be a critical concern in the research.In this article,the choice of the components,fundamental physical problems,the image reconstruction algorithm and the representative applications of micro-CT are summarized.Some results from our research group are also presented to show high-resolution images obtained by the micro-CT system.

  12. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-07-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  13. Temporal bone trauma and complications: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho, E-mail: anadoffemond@yahoo.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unit of Radiology and Imaging Diagnosis

    2013-03-15

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  14. Malignant uveal melanoma and similar lesions studied by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mafee, M.F.; Peyman, G.A.; McKusick, M.A.

    1985-08-01

    Forty-four patients with intraocular disease were studied by computed tomography (CT); in 19 cases malignant uveal melanoma was considered the likely diagnosis. CT proved to be accurate in determining the location and size of uveal melanomas, demonstrating scleral invasion, and differentiating melanoma from choroidal detachment or angioma, toxocariasis, and senile macular degeneration. On CT, uveal melanomas appeared as hyperdense lesions with slight to moderate contrast enhancement. Tumors thinner than 2 mm could not be seen. Using dynamic CT, the authors noted moderate peak amplitude, normal or delayed tissue transit time, and persistently elevated washout phase (downslope), indicating increased permeability as the result of an impaired tumor blood barrier. Histological types of uveal melanoma could not be differentiated on the basis of circulatory patterns. Dynamic CT may be useful in distinguishing uveal melanoma from choroidal hemangioma or hematoma.

  15. [Vascular assessment in stroke codes: role of computed tomography angiography].

    Science.gov (United States)

    Mendigaña Ramos, M; Cabada Giadas, T

    2015-01-01

    Advances in imaging studies for acute ischemic stroke are largely due to the development of new efficacious treatments carried out in the acute phase. Together with computed tomography (CT) perfusion studies, CT angiography facilitates the selection of patients who are likely to benefit from appropriate early treatment. CT angiography plays an important role in the workup for acute ischemic stroke because it makes it possible to confirm vascular occlusion, assess the collateral circulation, and obtain an arterial map that is very useful for planning endovascular treatment. In this review about CT angiography, we discuss the main technical characteristics, emphasizing the usefulness of the technique in making the right diagnosis and improving treatment strategies. Copyright © 2012 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  16. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-08-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  17. Dimensional measurement of micro-moulded parts by computed tomography

    DEFF Research Database (Denmark)

    Ontiveros, S.; Yagüe-Fabra, J.A.; Jiménez, R.

    2012-01-01

    Computed tomography (CT) is progressively assuming an important role in metrology applications and great efforts are being made in order to turn it into a reliable and standardized measuring technology. CT is typically used for non-destructive tests, but it is currently becoming very popular...... for dimensional metrology applications due to its strategic advantages such as the capability of performing measurements on both the component's surface and volume, allowing inspection possibilities to otherwise non-accessible internal features. This paper focuses on the dimensional verification of two micro......-injection moulded components, selected from actual industrial productions, using CT metrological tools. For this purpose, several parts have been measured with two different CT machines, and the results have been compared with the measurements obtained by other measuring systems. The experimental work carried out...

  18. Cysticercosis of the brain. The value of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almeida-Pinto, J.; Veiga-Pires, J.A.; Stocker, A.; Coelho, T.; Monteiro, L.

    Incidence and radiologic findings of neurocysticercosis were investigated in a series of 23 800 consecutive head examinations using computed tomography (CT). The condition was diagnosed in 168 case (0.7%). The parenchymatous form was the most common presentation (96.3%), while the meningeal form corresponded to only 11.9% of cases. These two forms coexisted in some cases. These findings reversed the knowledge on the condition based on conventional radiography. The different CT appearances in the brain are described and a new radiologic protocol for the CT evaluation of the condition is advocated, which includes a follow-up after a trial cure with Praziquantel in the presence of cysts not associated with suggestive brain calcifications. CT were more sensitive than conventional radiography in the differentiation between dead and living larvae, thus having an impact on the therapeutic management of the patients.

  19. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Atzingen, Augusto Castelli von [Clinical Radiology, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Tiferes, Dario Ariel; Matsumoto, Carlos Alberto; Nunes, Thiago Franchi; Maia, Marcos Vinicius Alvim Soares [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil)

    2012-05-15

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  20. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  1. Meningitis tuberculosa: Clinical findings and results of cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Trautmann, M.; Loddenkemper, R.; Hoffmann, H.G.

    1982-10-01

    Guided by 9 own observations between 1977 and 1981, new diagnostic facilities in tuberculous meningitis are discussed. For differentiation from viral meningitis, measurement of CSF lactic acid concentration in addition to that of CSF glucose has proved to be of value in recent years. In accordance with the literature, two cases of this series which were examined for CSF lactic acid concentration showed markedly elevated levels of 8,4 rsp. 10,4 mmol/l. In contrast to this, in viral meningitis usually values of less than 3.5 mmol/l are found. Additionally, the presence of hypochlor- and hyponatremia, which could be demonstrated in 6 of our 9 patients, may raise the suspicion of tuberculous etiology. In the series presented, cranial computed tomography was of greatest diagnostic value, enabling the diagnosis of hydrocephalus internus in 5, and basal arachnoiditis in 2 cases.

  2. Three-dimensional computed tomography of the acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S.; Muner, G.; Pozzi Mucelli, F.; Pozzi Mucelli, M.; Marotti, F.; Dalla Palma, L.

    1986-08-01

    Acetabular fractures represent a complex variety that are classified in different types. Conventional radiology is often inadequate to demonstrate and classify the fractures. Computed tomography (CT) has already been shown to be superior in this field. A further advantage of CT is represented by the recent availability of three-dimensional (3D) images that are realized from axial CT scans by means of a new software. The Authors report the applications of this new software to the study of the normal acetabulum and in patients with fractures. 3D images allows an effective demonstration of the fracture, its irradiation and the dislocation of bone fragments. The information is contained in one or few images rather than many axial images. Therefore the role of 3D images may be considered complementary to axial CT scans.

  3. Non-diffusing photochromic gel for optical computed tomography phantoms

    Science.gov (United States)

    Jordan, K.

    2013-06-01

    This study examines photochromic response in radiation sensitive hydrogels. Genipin, crosslinked, gelatin gel can support high resolution images because the chromophores do not diffuse. A low power, 633 nm He-Ne laser was used to write lines into the gels by a photobleaching reaction. Optical cone-beam computed tomography (CBCT) scans mapped the high resolution images in 3D with 0.25 mm voxel resolution. A straight line was written into a deformed gel and then readout in its relaxed, initial shape. The curved, photo-bleached line demonstrated deformable 3D dosimetry is possible with this system to the balloon edge. High resolution, photochromic images provide key information for characterizing optical CT scanners and 3D dosimeters. Many, ionizing radiation, dosimeter materials demonstrate either a photochromic or photothermal response, allowing this approach to be widely used in quantitative 3D scanning.

  4. Glasses for 3D ultrasound computer tomography: phase compensation

    Science.gov (United States)

    Zapf, M.; Hopp, T.; Ruiter, N. V.

    2016-03-01

    Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.

  5. Fossa navicularis magna detection on cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Syed, Ali Z. [Dept. of Oral and Maxillofacial Medicine and Diagnostic Sciences, School of Dental Medicine, Case Western Reserve University, Cleveland(United States); Mupparapu, Mel [Div. of Radiology, University of Pennsylvania School of Dental Medicine, Philadelphia (United States)

    2016-03-15

    Herein, we report and discuss the detection of fossa navicularis magna, a close radiographic anatomic variant of canalis basilaris medianus of the basiocciput, as an incidental finding in cone-beam computed tomography (CBCT) imaging. The CBCT data of the patients in question were referred for the evaluation of implant sites and to rule out pathology in the maxilla and mandible. CBCT analysis showed osseous, notch-like defects on the inferior aspect of the clivus in all four cases. The appearance of fossa navicularis magna varied among the cases. In some, it was completely within the basiocciput and mimicked a small rounded, corticated, lytic defect, whereas it appeared as a notch in others. Fossa navicularis magna is an anatomical variant that occurs on the inferior aspect of the clivus. The pertinent literature on the anatomical variations occurring in this region was reviewed.

  6. Computed tomography of the oropharynx in obstructive sleep apnea

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, S.G.; Gislason, T.; Lindholm, C.E.

    Computed tomography (CT) of the oropharynx was obtained in 32 consecutive adult patients with proven OSAS. An additional 15 patients with the same complaints, but without objective evidence of OSAS, were used as a control group, together with 20 normal subjects. The axial widths of the tongue and the genioglossus and hyoglossus muscles were measured by CT. Both the tongue and genioglossus widths were significantly larger in the OSAS patients than in the two control groups (p < 0.001). The increased tongue width will cause encroachment of the oropharyngeal airway below the level of the soft palate. Thus, CT can be used to measure the tongue size in order to evaluate its predictive value for the outcome of the UPPP procedure.

  7. Computed tomography using broadband Bessel THz beams and phase contrast.

    Science.gov (United States)

    Bitman, Assaf; Goldring, Sharone; Moshe, Inon; Zalevsky, Zeev

    2014-04-01

    We present new results demonstrating the capability of performing computed tomography (CT) using broadband Bessel terahertz (THz) beams. Nondiffractive beams such as these exhibit propagation-invariant lines of focus with an extended depth-of-field compared to conventional Gaussian beams. Using this property, we demonstrate a considerable improvement in the 3D reconstruction image of a synthetic sample through the backprojection algorithm. Only when THz Bessel beams are used, a full reconstruction of the object structure is made. Moreover, we use phase-contrast mechanism which improves the spatial resolution and reconstructed images. Our results highlight the potential in using nondiffractive Bessel beams to significantly improve 3D-image reconstruction of THz CT.

  8. Computed tomography of deep fat masses in multiple symmetrical lipomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Enzi, G.; Biondetti, P.R.; Fiore, D.; Mazzoleni, F.

    1982-07-01

    Deep fat masses were evaluated by computed tomography (CT) in 15 patients with multiple symmetrical lipomatosis. In 4 patients, peritracheal accumulations of fat were observed. In 3 of them, tracheal compression by lipomatous tissue was demonstrated: 2 were asymptomatic and the third severe respiratory insufficiency secondary to blockage of the air was by the vocal cords as the result of recurrent nerve palsy. In 6 patients, lipomatous tissue occupied the potential space between the spina scapulae and the trapezius, supraspinatus, and infraspinatus muscles. In 2, calcification of lipomatous masses was observed. There was no relationship between extension of subcutaneous fat and accumulation at deep sites. CT facilitates early detection of peritracheal lipomatous tissue and is helpful in follow-up when deep fat accumulation is responsible for space-occupying lesions requiring surgery.

  9. Dose reduction with adaptive bolus chasing computed tomography angiography.

    Science.gov (United States)

    Cai, Zhijun; Bai, Er-Wei; Wang, Ge; Sharafuddin, Melhem J; Abada, Hicham T

    2010-01-01

    Computed Tomography (CT) has become an effective diagnosis and evaluating tool in clinical; however, its radiation exposure has drawn great attention as more and more CT scans are performed every year. How to reduce the radiation dose and meanwhile keep the resultant CT images diagnosable becomes an important research topic. In this paper, we propose a dose reduction approach along with the adaptive bolus chasing CT Angiography (CTA) techniques, which are capable of tracking the contrast bolus peak over all the blood vessel segments during the CTA scan. By modulating the tube current (and collimator width) online, we can reduce the total radiation dose and maintain the contrast to noise ratio (CNR) of the blood vessel. Numerical experiments on reference DSA data sets show that by using the proposed dose reduction method, the effective radiation dose can be saved about 39%.

  10. Inspection of a Medieval Wood Sculpture Using Computer Tomography

    Science.gov (United States)

    Kapitany, K.; Somogyi, A.; Barsi, A.

    2016-06-01

    Computer tomography (CT) is an excellent technique for obtaining accurate 3D information about the human body. It allows to visualize the organs, bones and blood vessels, furthermore it enables to diagnose anomalies and diseases. Its spatial reconstruction capability supports other interesting applications, such as inspecting different, even valuable objects like ancient sculptures. Current paper presents a methodology of evaluating CT and video imagery through the example of investigating a wood Madonna with infant Jesus sculpture from the 14th century. The developed techniques extract the outer boundary of the statue, which has been triangulated to derive the surface model. The interior of the sculpture has also been revealed: the iron bolts and rivets as well as the woodworm holes can be mapped. By merging the interior and outer data (geometry and texture) interesting visualizations (perspective views, sections etc.) have been created.

  11. Software innovations in computed tomography for structural heart disease interventions.

    Science.gov (United States)

    Hell, Michaela; Marwan, Mohamed; Gaede, Luise; Achenbach, Stephan

    2016-05-17

    Computed tomography (CT) provides high, isotropic spatial resolution and has become firmly established in pre-procedural imaging for structural heart disease interventions. It allows determination of the exact dimensions of the target structure, provides information regarding the access route and permits identification of fluoroscopic projection angles to provide optimal visualisation for device placement. Several software solutions are available and have been systematically evaluated in the context of transcatheter aortic valve implantation (TAVI). The use of software products to perform automated measurements can be useful, especially when the experience and expertise regarding evaluation of CT in the context of structural heart disease are limited. In scientific studies, software has been demonstrated to provide accurate support for annulus sizing and prosthesis selection, to aid in reliably identifying patients in whom a transfemoral access may be problematic, and to suggest suitable angulations for fluoroscopic imaging to achieve an orthogonal view onto the aortic valve during implantation.

  12. Brain perfusion: computed tomography and magnetic resonance techniques.

    Science.gov (United States)

    Copen, William A; Lev, Michael H; Rapalino, Otto

    2016-01-01

    Cerebral perfusion imaging provides assessment of regional microvascular hemodynamics in the living brain, enabling in vivo measurement of a variety of different hemodynamic parameters. Perfusion imaging techniques that are used in the clinical setting usually rely upon X-ray computed tomography (CT) or magnetic resonance imaging (MRI). This chapter reviews CT- and MRI-based perfusion imaging techniques, with attention to image acquisition, clinically relevant aspects of image postprocessing, and fundamental differences between CT- and MRI-based techniques. Correlations with cerebrovascular physiology and potential clinical applications of perfusion imaging are reviewed, focusing upon the two major classes of neurologic disease in which perfusion imaging is most often performed: primary perfusion disorders (including ischemic stroke, transient ischemic attack, and reperfusion syndrome), and brain tumors. © 2016 Elsevier B.V. All rights reserved.

  13. Quantitative Pulmonary Imaging Using Computed Tomography and Magnetic Resonance Imaging

    Science.gov (United States)

    Washko, George R.; Parraga, Grace; Coxson, Harvey O.

    2011-01-01

    Measurements of lung function, including spirometry and body plethesmography, are easy to perform and are the current clinical standard for assessing disease severity. However, these lung functional techniques do not adequately explain the observed variability in clinical manifestations of disease and offer little insight into the relationship of lung structure and function. Lung imaging and the image based assessment of lung disease has matured to the extent that it is common for clinical, epidemiologic, and genetic investigation to have a component dedicated to image analysis. There are several exciting imaging modalities currently being used for the non-invasive study of lung anatomy and function. In this review we will focus on two of them, x-ray computed tomography and magnetic resonance imaging. Following a brief introduction of each method we detail some of the most recent work being done to characterize smoking-related lung disease and the clinical applications of such knowledge. PMID:22142490

  14. Clinicopathological characteristics and computed tomography features of mucinous gastric carcinoma.

    Science.gov (United States)

    Yan, C; Zhu, Z-G; Yan, M; Zhang, H; Pan, Z-L; Chen, J; Xiang, M; Chen, M-M; Liu, B-Y; Lin, Y-Z

    2011-01-01

    This study investigated the clinicopathological characteristics of mucinous gastric carcinoma (MGC) and assessed whether multidetector-row computed tomography (MDCT) could differentiate MGC from non-mucinous gastric carcinoma (NGC). Clinicopathological data from 542 patients with gastric carcinoma (23 MGC, 519 NGC), who underwent pre-operative MDCT examination and curative or palliative gastrectomy, were analysed. Only seven of the 23 patients with MGC were correctly diagnosed pre-operatively by endoscopic biopsy. The MGC patients had larger tumours, a higher frequency of lymph node metastases, were more likely to have tumours of tumour, node, metastasis stages III and IV, and were less likely to have a curative resection than NGC patients. In addition, five MGC patients had calcifications in the thickened gastric wall. In conclusion, MGC is rare and is detected mostly at an advanced stage. The diagnostic sensitivity of MGC by endoscopic biopsy was relatively low, whereas MDCT was helpful in distinguishing MGC from NGC.

  15. The possibilities of computer tomography in paecilomycosis of lungs

    Directory of Open Access Journals (Sweden)

    Abdusalom Ashurov

    2010-09-01

    Full Text Available We have analyzed computed tomography (CT results of chest in 56 patients with lung injures caused by paecilomycosis fungus at the age from 17 to 59 years. In our investigations, the perverted lung pattern due to pathology of interstitial tissue was observed in 52 (93% patients of 56 (with chronic bronchitis - 100%, exogenous-allergic alveolitis - 93%, recurrent pneumonia - 100% and with bronchial asthma - 80%. Analysis showed that CT provides wide opportunities in visualization of all spectrum of symptoms in lung tissue injury and could allow to increase the accuracy of determining the character and degree of injury, and also it could allow to determine localization and spreading of the pathological process.

  16. Gamma-ray computed tomography to characterize soil surface sealing

    Energy Technology Data Exchange (ETDEWEB)

    Pires, L.F.Luiz F. E-mail: lfpires@cena.usp.br; Macedo, Jose R. de; Souza, Manoel D. de; Bacchi, Osny O.S.; Reichardt, Klaus

    2002-09-01

    The application of sewage sludge as a fertilizer on soils may cause compacted surface layers (surface sealing), which can promote changes on soil physical properties. The objective of this work was to study the use of gamma-ray computed tomography, as a diagnostic tool for the evaluation of this sealing process through the measurement of soil bulk density distribution of the soil surface layer of samples subjected to sewage sludge application. Tomographic images were taken with a first generation tomograph with a resolution of 1 mm. The image analysis opened the possibility to obtain soil bulk density profiles and average soil bulk densities of the surface layer and to detect the presence of soil surface sealing. The sealing crust thickness was estimated to be in the range of 2-4 mm.

  17. Degeneration in dysplastic hips. A computer tomography study

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2005-01-01

    BACKGROUND: Hip dysplasia is considered pre-osteoarthritic, causing degeneration in young individuals. OBJECTIVE: To determine the pattern of degenerative change in moderate to severely dysplastic hips in young patients. DESIGN AND PATIENTS: One hundred and ninety-three consecutively......-referred younger patients with hip pain believed to be caused by hip dysplasia constituted the study cohort. The average age was 35.5 years (range, 15-61 years). They were examined by close-cut transverse pelvic and knee computed tomography and antero-posterior radiographs (CT). We identified 197 hips...... with moderate to severe dysplasia, and 78 hips with normal morphology in the study cohort, whilst 111 hip joints were borderline dysplastic according to preset definitions. Comparative analyses of anatomy and distribution of degeneration between dysplastic and normal hips in the study cohort were performed...

  18. Initial results of finger imaging using Photoacoustic Computed Tomography

    CERN Document Server

    van Es, Peter; Moens, Hein J Bernelot; Steenbergen, Wiendelt; Manohar, Srirang

    2014-01-01

    We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $\\mu$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential marke...

  19. Dacryocystography using computed tomography prior to external dacryocystorhinostomy

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ikue; Chijiiwa, Taeko [National Kyushu Medical Center, Fukuoka (Japan)

    2002-01-01

    We performed dacryocystography using computed tomography in 47 eyes of 45 patients of chronic dacryocystitis prior to external dacryocystorhinostomy. The radiopaque agent was injected into the lower canaliculus. The findings were useful in estimating the thickness of the bony wall of lacrimal fossa. The ethmoidal sinus was located adjacent and nasal to the lacrimal fossa in 11 eyes (23%). Care was needed in these cases not to create an anastomosis between the lacrimal sac and the ethmoidal sinus. The contrast medium was located in the nasolacrimal duct in 14 eyes (30%), suggesting that the obstruction was located in the lower nasolacrimal duct. Intraoperative irrigation-aspiration appeared to be indicated in these cases. Traumatic bony fracture with hypertrophy was present in one case, suggesting that nasolacrimal obstruction may be induced by facial trauma. (author)

  20. Quality Criteria Implementation for Brain Computed Tomography Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Calzado, A.; Rodriguez, R.; Munoz, A

    1998-07-01

    The main aim of this study was to implement the quality criteria proposed by the European Commission for brain computed tomography (CT) examinations. The proposed criteria were evaluated for 102 brain CT examinations, with a special emphasis on the diagnostic and radiation dose requirements. The examinations were selected at random from brain examinations performed over a period of a month at eight scanners of the CT Pace range. Achievement of image criteria was evaluated by two independent observers. The most important preliminary findings concerning image criteria fulfilment or lack of it and disagreements between observers are presented and discussed. The mean values of the proposed dosimetric quantities are compared to the reference values. The examinations performed with and without injection of a contrast agent are also analysed in relation to dosimetric quantities and criteria fulfilment. (author)

  1. Complicated cholecystitis: the complementary roles of sonography and computed tomography.

    Science.gov (United States)

    Charalel, Resmi A; Jeffrey, R Brooke; Shin, Lewis K

    2011-09-01

    Acute cholecystitis is a common cause of abdominal pain in the Western world. Unless treated promptly, patients with acute cholecystitis may develop complications such as gangrenous, perforated, or emphysematous cholecystitis. Because of the increased morbidity and mortality of complicated cholecystitis, early diagnosis and treatment are essential for optimal patient care. Nevertheless, complicated cholecystitis may pose significant challenges with cross-sectional imaging, including sonography and computed tomography (CT). Interpreting radiologists should be familiar with the spectrum of sonographic findings seen with complicated cholecystitis and as well as understand the complementary role of CT. Worrisome imaging findings for complicated cholecystitis include intraluminal findings (sloughed mucosa, hemorrhage, abnormal gas), gallbladder wall abnormalities (striations, asymmetric wall thickening, abnormal gas, loss of sonoreflectivity and contrast enhancement), and pericholecystic changes (echogenic fat, pericholecystic fluid, abscess formation). Finally, diagnosis of complicated cholecystitis by sonography and CT can guide alternative treatments including minimally invasive percutaneous and endoscopic options.

  2. Application of cone beam computed tomography in facial imaging science

    Institute of Scientific and Technical Information of China (English)

    Zacharias Fourie; Janalt Damstra; Yijin Ren

    2012-01-01

    The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years.Traditional 2D imaging has gradually being replaced by 3D images in different disciplines,particularly in the fields of orthodontics,maxillofacial surgery,plastic and reconstructive surgery,neurosurgery and forensic sciences.In most cases,3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton.The aim of this study was to review the types of imaging methods used for facial imaging.It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ.Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly importanl role in orthodontics and orthognathic surgery,special emphasis should be placed on discussing CBCT applications in facial evaluations.

  3. Transcolonic retrograde ureteric catheterization assisted by 3-d computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Snow, T.M.; Olivier, J.; Vigar, M. [Gold Coast Hospital, Southport, QLD (Australia). Department of Radiology; Parnham, A.P. [Gold Coast Hospital, Southport, QLD (Australia). Department of Radiology

    1999-08-01

    A 42-year-old woman had bladder extrophy at birth, treated by ureterocolic anastomosis of her single kidney. She suffered recurrent hyperammonaemia, leading to comas, but refused an ileal conduit. During her most recent coma, it was decided to divert her urine to test whether this would reduce hyperammonaemia: this was accomplished by transcolonic retrograde catheterization of the ureter. This was only possible after computed tomography ureterography to show the ureterocolic anastomosis. Ureterocolic anastomosis is associated with several complications, the best known being hyperchloraemic acidosis and potassium deficiency. There is also a very high incidence of stricture at the anastomosis, both benign and malignant. Hyperammonaemia is less common. It can lead to disturbance of consciousness and seizures. It is caused by reabsorption of ammonia from the colon, exacerbated by the presence of urea-splitting organisms. Copyright (1999) Blackwell Science Pty Ltd 8 refs., 4 figs.

  4. Cholecystocolonic fistula mimicking acute cholecystitis diagnosed unequivocally by computed tomography.

    Science.gov (United States)

    Chick, Jeffrey Forris Beecham; Chauhan, Nikunj Rashmikant; Paulson, Vera Ashley; Adduci, Alexander J

    2013-12-01

    Cholecystocolonic fistula is an uncommon potential complication of cholecystitis found intraoperatively in 0.06-0.14 % of patients undergoing cholecystectomy and 0.1-0.5 % of autopsy series. Although cholecystocolonic fistula is the second most common cholecystoenteric fistula, second only to cholecystoduodenal fistula, it is diagnosed preoperatively in only 7.9 % of patients. Failure to preoperatively diagnose cholecystocolonic fistula places surgeons in precarious positions, as they may be forced to convert a seemingly routine cholecystectomy to a more sophisticated procedure coupled with adhesiolysis, colonic suturing, or colonic resection. We report a young patient who presented to the emergency department with complaints indicative of acute cholecystitis; however, preoperative ultrasound was suggestive of a cholecystoenteric fistula. Computed tomography and pathology were pathognomonic with clear visualization of the cholecystocolonic fistulous tract.

  5. Building a 3D Computed Tomography Scanner From Surplus Parts.

    Science.gov (United States)

    Haidekker, Mark A

    2014-01-01

    Computed tomography (CT) scanners are expensive imaging devices, often out of reach for small research groups. Designing and building a CT scanner from modular components is possible, and this article demonstrates that realization of a CT scanner from components is surprisingly easy. However, the high costs of a modular X-ray source and detector limit the overall cost savings. In this article, the possibility of building a CT scanner with available surplus X-ray parts is discussed, and a practical device is described that incurred costs of less than $16,000. The image quality of this device is comparable with commercial devices. The disadvantage is that design constraints imposed by the available components lead to slow scan speeds and a resolution of 0.5 mm. Despite these limitations, a device such as this is attractive for imaging studies in the biological and biomedical sciences, as well as for advancing CT technology itself.

  6. Cone beam computed tomography: A new vision in dentistry

    Directory of Open Access Journals (Sweden)

    Manas Gupta

    2015-01-01

    Full Text Available Cone beam computed tomography (CBCT is a developing imaging technique designed to provide relatively low-dose high-spatial-resolution visualization of high-contrast structures in the head and neck and other anatomic areas. It is a vital content of a dental patient's record. A literature review demonstrated that CBCT has been utilized for oral diagnosis, oral and maxillofacial surgery, endodontics, implantology, orthodontics; temporomandibular joint dysfunction, periodontics, and restorative and forensic dentistry. Recently, higher emphasis has been placed on the CBCT expertise, the three-dimensional (3D images, and virtual models. This literature review showed that the different indications for CBCT are governed by the needs of the specific dental discipline and the type of procedure performed.

  7. Computed tomography of the retroperitoneum in patients with femoral neuropathy.

    Science.gov (United States)

    Eustace, S; McCarthy, C; O'Byrne, J; Breatnach, E; Fitzgerald, E

    1994-08-01

    The authors illustrate the value of computed tomography (CT) of the retroperitoneum in patients presenting with femoral nerve signs. They describe 28 such patients, examined at a tertiary-care hospital between June 1990 and January 1993, in whom CT of the retroperitoneum contributed significantly to the diagnosis. The patients, 19 males and 9 females, ranged in age from 11 to 81 years. CT showed disease of the psoas compartment in 17 cases; the condition was due to a malignant lesion in 9 cases and was secondary to infection in 5 and to other causes in 3. Disease of the iliacus compartment was shown in 11 cases; it was due to a malignant lesion in 6 cases and was secondary to hemorrhage in 2, to infection in 1 and to a bursa in 1. The diagnostic features of the diseases encountered are discussed, and the importance of performing CT early is stressed.

  8. Cone Beam Computed Tomography Evaluation of Inverted Mesiodentes.

    Science.gov (United States)

    Al-Sehaibany, Fares S; Marzouk, Hazem M; Salama, Fouad S

    2016-01-01

    A mesiodens is the most common type of supernumerary teeth. The purpose of this report is to present a rare occurrence of non-syndromic impacted inverted mesiodentes in an 8.5-year-old boy who presented with a chief complaint of delayed eruption of his permanent maxillary left central incisor. Occlusal and panoramic radiographs, as well as cone beam computed tomography (CBCT) with a three-dimensional (3-D) reconstruction image, confirmed that one supernumerary tooth had perforated the nasal fossa floor and the other was in close approximation to the to the same site. Surgical removal of both mesiodentes was indicated. Radiographic evidence of complete healing was observed 12 months following surgical removal. The use of CBCT with a 3-D reconstruction image as a tool in diagnosis and evaluation of healing after surgical removal is recommended.

  9. PET/Computed Tomography Scanning and Precision Medicine: Esophageal Cancer.

    Science.gov (United States)

    Goel, Reema; Subramaniam, Rathan M; Wachsmann, Jason W

    2017-10-01

    Esophageal cancer commonly has a poor prognosis, which requires an accurate diagnosis and early treatment to improve outcome. Other modalities for staging, such as endoscopic ultrasound imaging and computed tomography (CT) scans, have a role in diagnosis and staging. However, PET with fluorine-18 fluoro-2-deoxy-d-glucose/CT (FDG PET/CT) scanning allows for improved detection of distant metastatic disease and can help to prevent unnecessary interventions that would increase morbidity. FDG PET/CT scanning is valuable in the neoadjuvant chemotherapy assessment and predicting survival outcomes subsequent to surgery. FDG PET/CT scanning detects recurrent disease and metastases in follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Computed tomography dose optimisation in cystic fibrosis: A review.

    LENUS (Irish Health Repository)

    Ferris, Helena

    2016-04-28

    Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

  11. Recent Developments in Computed Tomography for Urolithiasis: Diagnosis and Characterization

    Directory of Open Access Journals (Sweden)

    P. D. Mc Laughlin

    2012-01-01

    Full Text Available Objective. To critically evaluate the current literature in an effort to establish the current role of radiologic imaging, advances in computed tomography (CT and standard film radiography in the diagnosis, and characterization of urinary tract calculi. Conclusion. CT has a valuable role when utilized prudently during surveillance of patients following endourological therapy. In this paper, we outline the basic principles relating to the effects of exposure to ionizing radiation as a result of CT scanning. We discuss the current developments in low-dose CT technology, which have resulted in significant reductions in CT radiation doses (to approximately one-third of what they were a decade ago while preserving image quality. Finally, we will discuss an important recent development now commercially available on the latest generation of CT scanners, namely, dual energy imaging, which is showing promise in urinary tract imaging as a means of characterizing the composition of urinary tract calculi.

  12. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shohei; Tani, Kenji; Ishigatsubo, Yoshiaki and others

    1988-09-01

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis.

  13. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2001-09-15

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  14. Effect of object location on the density measurement in cone-beam computed tomography versus multislice computed tomography.

    Science.gov (United States)

    Eskandarloo, Amir; Abdinian, Mehrdad; Salemi, Fatemeh; Hashemzadeh, Zahra; Safaei, Mehran

    2012-12-01

    Bone density measurement in a radiographic view is a valuable method for evaluating the density of bone quality before performing some dental procedures such as, dental implant placements. It seems that Cone-Beam Computed Tomography (CBCT) can be used as a diagnostic tool for evaluating the density of the bone, prior to any treatment, as the reported radiation dose in this method is minimal. The aim of this study is to investigate the effect of object location on the density measurement in CBCT versus Multislice computed tomography (CT). In an experimental study, three samples with similar dimensions, but different compositions, different densities (Polyethylene, Polyamide, Polyvinyl Chloride), and three bone pieces of different parts of the mandibular bone were imaged in three different positions by CBCT and Multislice CT sets. The average density value was computed for each sample in each position. Then the data obtained from each CBCT was converted to a Hounsfield unit and evaluated using a single variable T analysis. A P value <0.05 was considered to be significant. The density in a Multislice CT is stable in the form of a Hounsfield Number, but this density is variable in the images acquired through CBCT, and the change in the position results in significant changes in the density. In this study, a statistically significant difference (P value = 0.000) has been observed for the position of the sample and its density in CBCT in comparison to Multislice CT. Density values in CBCT are not real because they are affected by the position of the object in the machine.

  15. Quantification and clinical relevance of head motion during computed tomography.

    Science.gov (United States)

    Wagner, Arne; Schicho, Kurt; Kainberger, Franz; Birkfellner, Wolfgang; Grampp, Stephan; Ewers, Rolf

    2003-11-01

    To quantify the 3-dimensional translation and rotation components of head motion during computed tomography and to analyze the influence of such motion on perceptible artifacts and distortion of volume image data sets. Using high-precision optoelectronic motion-capture technology, changes in patient head position during axial CT scanning were registered in 20 cases and 2 phantoms with a spatial relative resolution better than 0.003 cm. Statistical analysis was performed on a base of 6-dimensional measurement-vectors, each with 3 translation and 3 rotation values. Because of the recording frequency of the tracking system, more than 80000 values were included in a statistical analysis. All 20 patients had head motion during the CT scanning, with only 4 of 20 patients showing perceptible motion artifacts. The frequency, the extent, and the direction of the movements did not correlate with either the observations made by the radiologic staff or with the patient's subjective estimation of comfort. Translation movements of the head during CT accounted for a maximum of 0.5 cm and rotations of more than 2 degrees without perceptible motion artifacts. The extent of positional changes of the head was found to correlate with the duration of scanning (Pearson's correlation coefficient: 0.647 for translation shifts, 0.453 for rotation shifts). The mean direction of head motion could be characterized predominantly as a rotation around the longitudinal axis of the body (xy plane) at a significance level of 0.01. Computed tomography evaluations of the head performed without rigid fixation suffer a spatial distortion of the volume image data sets, caused by interimage motion. The absence of motion artifacts is not correlated with the absence of motion.

  16. Multiscale and multimodality computed tomography for cortical bone analysis

    Science.gov (United States)

    Ostertag, A.; Peyrin, F.; Gouttenoire, P. J.; Laredo, J. D.; DeVernejoul, M. C.; Cohen Solal, M.; Chappard, C.

    2016-12-01

    In clinical studies, high resolution peripheral quantitative computed tomography (HR-pQCT) is used to separately evaluate cortical bone and trabecular bone with an isotropic voxel of 82 µm3, and typical cortical parameters are cortical density (D.comp), thickness (Ct.Th), and porosity (Ct.Po). In vitro, micro-computed tomography (micro-CT) is used to explore the internal cortical bone micro-structure with isotropic voxels and high resolution synchrotron radiation (SR); micro-CT is considered the ‘gold standard’. In 16 tibias and 8 femurs, HR-pQCT measurements were compared to conventional micro-CT measurements. To test modality effects, conventional micro-CT measurements were compared to SR micro-CT measurements at 7.5 µm3 SR micro-CT measurements were also tested at different voxel sizes for the femurs, specifically, 7.5 µm3 versus 2.8 µm3. D.comp (r  =  -0.88, p  images provided consistent results compared to those obtained using conventional micro-CT at the distal tibia. D.comp was highly correlated to Po.V/TV because it considers both the micro-porosity (Haversian systems) and macro-porosity (resorption lacunae) of cortical bone. The complexity of canal organization, (including shape, connectivity, and surface) are not fully considered in conventional micro-CT in relation to beam hardening and cone beam reconstruction artifacts. With the exception of Po.V/TV measurements, morphological and topological measurements depend on the characteristics of the x-ray beam, and to a lesser extent, on image resolution.

  17. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.

  18. Evaluation of computer tomography in cerebro-vascular disease (Strokes)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Sik; Baek, Seung Yon; Rhee, Chung Sik; Kim, Hee Seup [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1984-06-15

    Most of cerebrovascular disease are composed of vascular occulusive changes and hemorrhage. Now a day, the computed tomography is the best way for evaluation of cerebrovascular disease including detection of nature, location, and associated changes. This study includes evaluation of computed tomography of 70 patients with cerebrovascular disease during the period of 10 months from April. 1983 to Feb. 1984 in Department of Radiology, Ewha Womans University Hospital. The results were as follows: 1. Age distribution of the total 70 patients was broad ranging from 25 years to 79 years. 78.6% of patients were over the age of 50. The male and female sex ratio was 1.4:1. 2. 4 out of 70 patients were normal and 66 patients revealed abnormal on C.T. findings; those were intracranial hemorrhage (28 patients), cerebral infarction (34 patients) and brain atrophy (4 patients). 3. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (28 cases), and next was basal ganglia (2 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. 4. In cases of intracranial hemorrhage, the basal ganglia was most common site of lesion (15 cases). The next common site was cerebral hemisphere (9 cases). 6 patients of all intracranial hemorrhage were combined with intraventricular hemorrhage. Ratio of right and left was 2:3. 5. In patients with motor weakness or hemiparesis, more common findings on CT scan were cerebral infarction. In case with hemiplegia, more common CT findings were intracerebral hemorrhage. 6. Of the 40 cases thought to be cerebral infarction initially by clinical findings and spinal tap. 8 cases (20.0%) were proved to be cerebral hemorrhage by the CT scan. However, of the 22 cases thought to be cerebral hemorrhage, initially, only two cases (9.0%) were cerebral infarction.

  19. Actinomycosis involving the liver. Computed tomography/ultrasound correlation.

    Science.gov (United States)

    Sheth, S; Fishman, E K; Sanders, R

    1987-06-01

    The clinical profile of pelvic actinomycosis, which is being recognized with increased frequency in IUD users, can be misleading in such patients and lead to dangerous delays in diagnosis. The authors present a case in which an IUD user initially sought medical attention for multiple liver abscesses secondary to spread from unsuspected ovarian actinomycosis. The 43-year-old patient, who was admitted with right upper quadrant pain and fever, had a 15-year history of IUD use, although the device had been removed 1 year prior to admission for apparent infection in the left ovary. Ultrasound revealed mixed cystic and solid liver lesions as well as a complex subcapsular fluid collection. A solid left adnexal mass was demonstrated in the pelvis. Computed tomography scan indicated extension of 1 of the complex cystic liver lesions through the liver capsule and into the abdominal wall. Needle aspirations of the liver lesions yielded thick pus that was later identified as Actinomyces israelii. Actinomycosis was evident in the ovarian lesion. Colonization of the vagina and uterus by actinomycosis has been reported by 1.6-5.3% of IUD users, and the risk appears to increase when the same IUD is used for a prolonged time period. In this case, neither the computed tomography scan nor ultrasound suggested an inflammatory process of the left ovary. Aspiration of a liver lesion under ultrasound guidance was necessary for the correct diagnosis. Since actinomycosis has the potential to spread to extrapelvic organs such as the peritoneum, liver, and brain, early diagnosis is essential.

  20. Artifacts in computed tomography scanning of moving objects.

    Science.gov (United States)

    Chen, George T Y; Kung, Jong H; Beaudette, Kevin P

    2004-01-01

    Target volumes in the thorax and abdomen are commonly computed tomography (CT) scanned during light respiration. In this article, we analyze the distortions introduced in helical scanning of moving objects. Objects of known geometry are placed on a moving sled and scanned in a multirow helical CT scanner. The motion of the sled approximates the magnitude and velocity of organ movement in patients during light respiration (amplitude 1 cm, period 4 seconds). Scans of the phantom are obtained in high speed mode at incremental phases of respiration, and the resulting images are compared with scans obtained when the phantom is static. Computer simulations of the scan process are also performed to interpret the results and extend the analysis to a greater range of parameters in scanning, motion, and object size. Resulting scans show that spherical test objects can be shortened by as much as 2 cm or twice the periodic motion amplitude. Object shape was significantly distorted, and the geometric center of the object was displaced by as much as +/-0.8 cm. Computer simulation results qualitatively agree with the experimentally observed phantom images. These simulations predict that the effect is clearly observable even if the amplitude is decreased to 0.5 cm. Implications of scanning moving objects on treatment planning are discussed.