WorldWideScience

Sample records for dual-mode ultrasound arrays

  1. HIFU Monitoring and Control with Dual-Mode Ultrasound Arrays

    Science.gov (United States)

    Casper, Andrew Jacob

    The biological effects of high-intensity focused ultrasound (HIFU) have been known and studied for decades. HIFU has been shown capable of treating a wide variety of diseases and disorders. However, despite its demonstrated potential, HIFU has been slow to gain clinical acceptance. This is due, in part, to the difficulty associated with robustly monitoring and controlling the delivery of the HIFU energy. The non-invasive nature of the surgery makes the assessment of treatment progression difficult, leading to long treatment times and a significant risk of under treatment. This thesis research develops new techniques and systems for robustly monitoring HIFU therapies for the safe and efficacious delivery of the intended treatment. Systems and algorithms were developed for the two most common modes of HIFU delivery systems: single-element and phased array applicators. Delivering HIFU with a single element transducer is a widely used technique in HIFU therapies. The simplicity of a single element offers many benefits in terms of cost and overall system complexity. Typical monitoring schemes rely on an external device (e.g. diagnostic ultrasound or MRI) to assess the progression of therapy. The research presented in this thesis explores using the same element to both deliver and monitor the HIFU therapy. The use of a dual-mode ultrasound transducer (DMUT) required the development of an FPGA based single-channel arbitrary waveform generator and high-speed data acquisition unit. Data collected from initial uncontrolled ablations led to the development of monitoring and control algorithms which were implemented directly on the FPGA. Close integration between the data acquisition and arbitrary waveform units allowed for fast, low latency control over the ablation process. Results are presented that demonstrate control of HIFU therapies over a broad range of intensities and in multiple in vitro tissues. The second area of investigation expands the DMUT research to an

  2. Adaptive lesion formation using dual mode ultrasound array system

    Science.gov (United States)

    Liu, Dalong; Casper, Andrew; Haritonova, Alyona; Ebbini, Emad S.

    2017-03-01

    We present the results from an ultrasound-guided focused ultrasound platform designed to perform real-time monitoring and control of lesion formation. Real-time signal processing of echogenicity changes during lesion formation allows for identification of signature events indicative of tissue damage. The detection of these events triggers the cessation or the reduction of the exposure (intensity and/or time) to prevent overexposure. A dual mode ultrasound array (DMUA) is used for forming single- and multiple-focus patterns in a variety of tissues. The DMUA approach allows for inherent registration between the therapeutic and imaging coordinate systems providing instantaneous, spatially-accurate feedback on lesion formation dynamics. The beamformed RF data has been shown to have high sensitivity and specificity to tissue changes during lesion formation, including in vivo. In particular, the beamformed echo data from the DMUA is very sensitive to cavitation activity in response to HIFU in a variety of modes, e.g. boiling cavitation. This form of feedback is characterized by sudden increase in echogenicity that could occur within milliseconds of the application of HIFU (see http://youtu.be/No2wh-ceTLs for an example). The real-time beamforming and signal processing allowing the adaptive control of lesion formation is enabled by a high performance GPU platform (response time within 10 msec). We present results from a series of experiments in bovine cardiac tissue demonstrating the robustness and increased speed of volumetric lesion formation for a range of clinically-relevant exposures. Gross histology demonstrate clearly that adaptive lesion formation results in tissue damage consistent with the size of the focal spot and the raster scan in 3 dimensions. In contrast, uncontrolled volumetric lesions exhibit significant pre-focal buildup due to excessive exposure from multiple full-exposure HIFU shots. Stopping or reducing the HIFU exposure upon the detection of such an

  3. Non-invasive transcranial surgery with dual-mode ultrasound arrays

    Science.gov (United States)

    Haritonova, Alyona; Liu, Dalong; Wilken-Resman, Elias; Bayat, Mahdi; Wang, Xiao; Chen, Wei; Divani, Afshin; Ebbini, Emad

    2017-03-01

    We present the first transcranial mapping of temperature with Dual-Mode Ultrasound Arrays (DMUAs), with subsequent validation of transskull ultrasound therapy guidance and monitoring in a small rodent model. Experiments were conducted in sacrificed rats, utilizing the custom designed DMUA platform manufactured in our laboratory. First, careful examination of DMUA imaging through the skull was conducted, where a fine 50μm wire was embedded within the brain tissue. Second, anatomical landmarks were visualized by co-registering two volumes, volume of synthetic aperture (SA) images acquired with DMUA and a 9.4T MRI volume acquired in live rats prior to the sacrifice. Third, subtherapeutic shot delivery through the skull was tested, where a set of five varying intensity shots were deposited below the skull surface. Shot delivery and temperature monitoring were performed with DMUA, and compared with the thermocouple data acquired close to the therapeutic focus. This study was an exploratory effort to validate ultrasound therapy delivery and monitoring in transcranial applications with DMUAs. In conclusion, DMUAs offer a unique advantage by providing real-time feedback by means of temperature monitoring with a high degree of spatial localization.

  4. A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device

    Science.gov (United States)

    Crake, Calum; Brinker, Spencer T.; Coviello, Christian M.; Livingstone, Margaret S.; McDannold, Nathan J.

    2018-03-01

    Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5  ×  0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within  ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a  ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.

  5. Microscale characterization of the viscoelastic properties of hydrogel biomaterials using dual-mode ultrasound elastography.

    Science.gov (United States)

    Hong, Xiaowei; Stegemann, Jan P; Deng, Cheri X

    2016-05-01

    Characterization of the microscale mechanical properties of biomaterials is a key challenge in the field of mechanobiology. Dual-mode ultrasound elastography (DUE) uses high frequency focused ultrasound to induce compression in a sample, combined with interleaved ultrasound imaging to measure the resulting deformation. This technique can be used to non-invasively perform creep testing on hydrogel biomaterials to characterize their viscoelastic properties. DUE was applied to a range of hydrogel constructs consisting of either hydroxyapatite (HA)-doped agarose, HA-collagen, HA-fibrin, or preosteoblast-seeded collagen constructs. DUE provided spatial and temporal mapping of local and bulk displacements and strains at high resolution. Hydrogel materials exhibited characteristic creep behavior, and the maximum strain and residual strain were both material- and concentration-dependent. Burger's viscoelastic model was used to extract characteristic parameters describing material behavior. Increased protein concentration resulted in greater stiffness and viscosity, but did not affect the viscoelastic time constant of acellular constructs. Collagen constructs exhibited significantly higher modulus and viscosity than fibrin constructs. Cell-seeded collagen constructs became stiffer with altered mechanical behavior as they developed over time. Importantly, DUE also provides insight into the spatial variation of viscoelastic properties at sub-millimeter resolution, allowing interrogation of the interior of constructs. DUE presents a novel technique for non-invasively characterizing hydrogel materials at the microscale, and therefore may have unique utility in the study of mechanobiology and the characterization of hydrogel biomaterials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. A Dual-Mode Large-Arrayed CMOS ISFET Sensor for Accurate and High-Throughput pH Sensing in Biomedical Diagnosis.

    Science.gov (United States)

    Huang, Xiwei; Yu, Hao; Liu, Xu; Jiang, Yu; Yan, Mei; Wu, Dongping

    2015-09-01

    The existing ISFET-based DNA sequencing detects hydrogen ions released during the polymerization of DNA strands on microbeads, which are scattered into microwell array above the ISFET sensor with unknown distribution. However, false pH detection happens at empty microwells due to crosstalk from neighboring microbeads. In this paper, a dual-mode CMOS ISFET sensor is proposed to have accurate pH detection toward DNA sequencing. Dual-mode sensing, optical and chemical modes, is realized by integrating a CMOS image sensor (CIS) with ISFET pH sensor, and is fabricated in a standard 0.18-μm CIS process. With accurate determination of microbead physical locations with CIS pixel by contact imaging, the dual-mode sensor can correlate local pH for one DNA slice at one location-determined microbead, which can result in improved pH detection accuracy. Moreover, toward a high-throughput DNA sequencing, a correlated-double-sampling readout that supports large array for both modes is deployed to reduce pixel-to-pixel nonuniformity such as threshold voltage mismatch. The proposed CMOS dual-mode sensor is experimentally examined to show a well correlated pH map and optical image for microbeads with a pH sensitivity of 26.2 mV/pH, a fixed pattern noise (FPN) reduction from 4% to 0.3%, and a readout speed of 1200 frames/s. A dual-mode CMOS ISFET sensor with suppressed FPN for accurate large-arrayed pH sensing is proposed and demonstrated with state-of-the-art measured results toward accurate and high-throughput DNA sequencing. The developed dual-mode CMOS ISFET sensor has great potential for future personal genome diagnostics with high accuracy and low cost.

  7. A Google Glass navigation system for ultrasound and fluorescence dual-mode image-guided surgery

    Science.gov (United States)

    Zhang, Zeshu; Pei, Jing; Wang, Dong; Hu, Chuanzhen; Ye, Jian; Gan, Qi; Liu, Peng; Yue, Jian; Wang, Benzhong; Shao, Pengfei; Povoski, Stephen P.; Martin, Edward W.; Yilmaz, Alper; Tweedle, Michael F.; Xu, Ronald X.

    2016-03-01

    Surgical resection remains the primary curative intervention for cancer treatment. However, the occurrence of a residual tumor after resection is very common, leading to the recurrence of the disease and the need for re-resection. We develop a surgical Google Glass navigation system that combines near infrared fluorescent imaging and ultrasonography for intraoperative detection of sites of tumor and assessment of surgical resection boundaries, well as for guiding sentinel lymph node (SLN) mapping and biopsy. The system consists of a monochromatic CCD camera, a computer, a Google Glass wearable headset, an ultrasonic machine and an array of LED light sources. All the above components, except the Google Glass, are connected to a host computer by a USB or HDMI port. Wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A control program is written in C++ to call OpenCV functions for image calibration, processing and display. The technical feasibility of the system is tested in both tumor simulating phantoms and in a human subject. When the system is used for simulated phantom resection tasks, the tumor boundaries, invisible to the naked eye, can be clearly visualized with the surgical Google Glass navigation system. This system has also been used in an IRB approved protocol in a single patient during SLN mapping and biopsy in the First Affiliated Hospital of Anhui Medical University, demonstrating the ability to successfully localize and resect all apparent SLNs. In summary, our tumor simulating phantom and human subject studies have demonstrated the technical feasibility of successfully using the proposed goggle navigation system during cancer surgery.

  8. Dual-Mode Combustor

    Science.gov (United States)

    Trefny, Charles J (Inventor); Dippold, Vance F (Inventor)

    2013-01-01

    A new dual-mode ramjet combustor used for operation over a wide flight Mach number range is described. Subsonic combustion mode is usable to lower flight Mach numbers than current dual-mode scramjets. High speed mode is characterized by supersonic combustion in a free-jet that traverses the subsonic combustion chamber to a variable nozzle throat. Although a variable combustor exit aperture is required, the need for fuel staging to accommodate the combustion process is eliminated. Local heating from shock-boundary-layer interactions on combustor walls is also eliminated.

  9. Handheld ultrasound array imaging device

    Science.gov (United States)

    Hwang, Juin-Jet; Quistgaard, Jens

    1999-06-01

    A handheld ultrasound imaging device, one that weighs less than five pounds, has been developed for diagnosing trauma in the combat battlefield as well as a variety of commercial mobile diagnostic applications. This handheld device consists of four component ASICs, each is designed using the state of the art microelectronics technologies. These ASICs are integrated with a convex array transducer to allow high quality imaging of soft tissues and blood flow in real time. The device is designed to be battery driven or ac powered with built-in image storage and cineloop playback capability. Design methodologies of a handheld device are fundamentally different to those of a cart-based system. As system architecture, signal and image processing algorithm as well as image control circuit and software in this device is deigned suitably for large-scale integration, the image performance of this device is designed to be adequate to the intent applications. To elongate the battery life, low power design rules and power management circuits are incorporated in the design of each component ASIC. The performance of the prototype device is currently being evaluated for various applications such as a primary image screening tool, fetal imaging in Obstetrics, foreign object detection and wound assessment for emergency care, etc.

  10. Braking System Integration in Dual Mode Systems

    Science.gov (United States)

    1974-05-01

    An optimal braking system for Dual Mode is a complex product of vast number of multivariate, interdependent parameters that encompass on-guideway and off-guideway operation as well as normal and emergency braking. : Details of, and interralations amo...

  11. Automotive dual-mode hydrogen generation system

    Science.gov (United States)

    Kelly, D. A.

    The automotive dual mode hydrogen generation system is advocated as a supplementary hydrogen fuel means along with the current metallic hydride hydrogen storage method for vehicles. This system consists of utilizing conventional electrolysis cells with the low voltage dc electrical power supplied by two electrical generating sources within the vehicle. Since the automobile engine exhaust manifold(s) are presently an untapped useful source of thermal energy, they can be employed as the heat source for a simple heat engine/generator arrangement. The second, and minor electrical generating means consists of multiple, miniature air disk generators which are mounted directly under the vehicle's hood and at other convenient locations within the engine compartment. The air disk generators are revolved at a speed which is proportionate to the vehicles forward speed and do not impose a drag on the vehicles motion.

  12. Dual-Mode Scramjet Flameholding Operability Measurements

    Science.gov (United States)

    Donohue, James M.

    2012-01-01

    Flameholding measurements were made in two different direct connect combustor facilities that were designed to simulate a cavity flameholder in the flowfield of a hydrocarbon fueled dual-mode scramjet combustor. The presence of a shocktrain upstream of the flameholder has a significant impact on the inlet flow to the combustor and on the flameholding limits. A throttle was installed in the downstream end of the test rigs to provide the needed back-pressurization and decouple the operation of the flameholder from the backpressure formed by heat release and thermal choking, as in a flight engine. Measurements were made primarily with ethylene fuel but a limited number of tests were also performed with heated gaseous JP-7 fuel injection. The flameholding limits were measured by ramping inlet air temperature down until blowout was observed. The tests performed in the United Technologies Research Center (UTRC) facility used a hydrogen fueled vitiated air heater, Mach 2.2 and 3.3 inlet nozzles, a scramjet combustor rig with a 1.666 by 6 inch inlet and a 0.65 inch deep cavity. Mean blowout temperature measured at the baseline condition with ethylene fuel, the Mach 2.2 inlet and a cavity pressure of 21 psia was 1502 oR. Flameholding sensitivity to a variety of parameters was assessed. Blowout temperature was found to be most sensitive to fuel injection location and fuel flowrates and surprisingly insensitive to operating pressure (by varying both back-pressurization and inlet flowrate) and inlet Mach number. Video imaging through both the bottom and side wall windows was collected simultaneously and showed that the flame structure was quite unsteady with significant lateral movements as well as movement upstream of the flameholder. Experiments in the University of Virginia (UVa) test facility used a Mach 2 inlet nozzle with a 1 inch by 1.5 inch exit cross section, an aspect ratio of 1.5 versus 3.6 in the UTRC facility. The UVa facility tests were designed to measure the

  13. Ultrasound cylindrical phased array for transoesophageal thermal therapy: initial studies

    Energy Technology Data Exchange (ETDEWEB)

    Melodelima, David [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France); Lafon, Cyril [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France); Prat, Frederic [Centre Hospitalier Bicetre, 78 Avenue General Leclerc, 94275 Le Kremlin Bicetre (France); Birer, Alain [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France); Cathignol, Dominique [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France)

    2002-12-07

    This work was undertaken to investigate the feasibility of constructing a cylindrical phased array composed of 64 elements spread around the periphery (OD 10.6 mm) for transoesophageal ultrasound thermotherapy. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were successively excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. For these feasibility studies, we used a cylindrical prototype (OD 10.6 mm) composed of 16 elementary transducers distributed over a quarter of the cylinder, all operating at 4.55 MHz. The active part was mechanically reinforced by a rigid damper structure behind the transducers. It was shown that an ultrasound field similar to that emitted by a plane transducer could be generated. Ex vivo experiments on pig's liver demonstrated that the ultrasound beam could be accurately rotated to generate sector-based lesions to a suitable depth (up to 19 mm). Throughout these experiments, exposures lasting 20 s were delivered at an acoustic intensity of 17 W cm{sup -2}. By varying the power from exposure to exposure, the depth of the lesion at different angles could be controlled.

  14. A nonlinear lumped model for ultrasound systems using CMUT arrays.

    Science.gov (United States)

    Satir, Sarp; Degertekin, F Levent

    2015-10-01

    We present a nonlinear lumped model that predicts the electrical input-output behavior of an ultrasonic system using CMUTs with arbitrary array/membrane/electrode geometry in different transmit-receive configurations and drive signals. The receive-only operation, where the electrical output signal of the CMUT array in response to incident pressure field is calculated, is included by modifying the boundary elementbased vibroacoustic formulation for a CMUT array in rigid baffle. Along with the accurate large signal transmit model, this formulation covers pitch-catch and pulse-echo operation when transmit and receive signals can be separated in time. In cases when this separation is not valid, such as CMUTs used in continuous wave transmit-receive mode, pulse-echo mode with a nearby hard or soft wall or in a bounded space such as in a microfluidic channel, an efficient formulation based on the method of images is used. Some of these particular applications and the overall modeling approach have been validated through comparison with finite element analysis on specific examples including CMUTs with multiple electrodes. To further demonstrate the capability of the model for imaging applications, the two-way response of a partial dual-ring intravascular ultrasound array is simulated using a parallel computing cluster, where the output currents of individual array elements are calculated for given input pulse and compared with experimental results. With its versatility, the presented model can be a useful tool for rapid iterative CMUT-based system design and simulation for a broad range of ultrasonic applications.

  15. Examining Policy Guidelines for Distance Education in Dual Mode ...

    African Journals Online (AJOL)

    The study reports a case of distance education policy in the Kwame Nkrumah University of Science and Technology (KNUST), a dual mode University in Ghana. The interview method was used to obtain information from 21 purposively selected key informants in the University. Policy documents that addressed Distance ...

  16. A flexible dual-mode proximity sensor based on cooperative sensing for robot skin applications

    Science.gov (United States)

    Huang, Ying; Cai, Xia; Kan, Wenqing; Qiu, Shihua; Guo, Xiaohui; Liu, Caixia; Liu, Ping

    2017-08-01

    A flexible dual-mode proximity sensor has been designed and implemented, which is capable of combining capacitive-resistive detection in this paper. The capacitive type proximity sensor detecting is defined as mode-C, and the resistive type proximity sensor detecting is defined as mode-R. The characteristics of the proximity sensor are as follows: (1) the theoretical mode is developed which indicates that this proximity sensor can reflect proximity information accurately; (2) both sensing modes are vertically integrated into a sandwich-like chip with an 8 mm × 12 mm unit area. The thickness of a mode-R sensing material (graphene nanoplatelets) and mode-C dielectric (the mixture of carbon black and silicone rubber) is 1 mm and 2.5 mm, respectively; (3) for mode-R, the linearity of temperature-resistance curve can achieve 0.998 in the temperature range from 25°C to 65°C. And for mode-C, various materials can be successfully detected with fast response and high reversibility. Meanwhile, the study compensated the influence of object temperature to ensure mode-C properly works. A cooperative sensing test shows that R-C dual modes sense effectively which can enlarge the sensing distance compared with the single mode proximity sensor. The fabrication of this sensor is convenient, and the integrity of a flexible sandwich-like structure based on dual modes is beneficial to form arrays, which is suitable to be used in skin-like sensing applications.

  17. A flexible dual-mode proximity sensor based on cooperative sensing for robot skin applications.

    Science.gov (United States)

    Huang, Ying; Cai, Xia; Kan, Wenqing; Qiu, Shihua; Guo, Xiaohui; Liu, Caixia; Liu, Ping

    2017-08-01

    A flexible dual-mode proximity sensor has been designed and implemented, which is capable of combining capacitive-resistive detection in this paper. The capacitive type proximity sensor detecting is defined as mode-C, and the resistive type proximity sensor detecting is defined as mode-R. The characteristics of the proximity sensor are as follows: (1) the theoretical mode is developed which indicates that this proximity sensor can reflect proximity information accurately; (2) both sensing modes are vertically integrated into a sandwich-like chip with an 8 mm × 12 mm unit area. The thickness of a mode-R sensing material (graphene nanoplatelets) and mode-C dielectric (the mixture of carbon black and silicone rubber) is 1 mm and 2.5 mm, respectively; (3) for mode-R, the linearity of temperature-resistance curve can achieve 0.998 in the temperature range from 25  ° C to 65  ° C. And for mode-C, various materials can be successfully detected with fast response and high reversibility. Meanwhile, the study compensated the influence of object temperature to ensure mode-C properly works. A cooperative sensing test shows that R-C dual modes sense effectively which can enlarge the sensing distance compared with the single mode proximity sensor. The fabrication of this sensor is convenient, and the integrity of a flexible sandwich-like structure based on dual modes is beneficial to form arrays, which is suitable to be used in skin-like sensing applications.

  18. Development and Use of the Dual-Mode Plasma Torch

    International Nuclear Information System (INIS)

    Womack, R.; Shuey, M.

    2002-01-01

    After several years of development, a commercially available high-temperature treatment system has been developed and installed that treats heterogeneous low-level radioactive waste. High temperature plasma processing, unique torch design and operating features make it feasible to achieve a volume reduced, permanent, high integrity waste form while eliminating the personnel exposure and costs associated with conventional sorting, characterizing and handling. Plasma technology can also be used to treat previous conditioned waste packages that no longer meet the current acceptance criteria for final disposal. Plasma treatment can result, in many cases, in a substantial volume reduction, which lowers the final disposal costs. This paper covers the recently patented dual mode plasma torch design(1), the lessons learned that fostered its development and the advantages it brings to radioactive waste processing. This paper also provides current full scale Plasma Arc Centrifugal Treatment (PACT) project status and how the dual mode torch is being used in the PACT system

  19. Dual-Mode Patch Filter with Metal Wall Structures

    Directory of Open Access Journals (Sweden)

    D. Kang

    2013-01-01

    Full Text Available A dual-mode patch filter with metal wall structures is presented. The proposed structure consists of substrate 1 with metal wall structures and substrate 2 with a patch resonator. Because the symmetry of the structure can be perturbed by both long and short strips of the metal wall structures, the dual mode is achieved. The inductive element is introduced to the patch resonator through vias of the metal wall structures. The capacitive element is introduced through a gap between the patch resonator and the metal strips. The measured 3 dB fractional bandwidth for the passband is 10.4%, and the measured minimum insertion loss is 1.3 dB.

  20. Acoustical cross-talk in row–column addressed 2-D transducer arrays for ultrasound imaging

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lehrmann; Jensen, Jørgen Arendt; Thomsen, Erik Vilain

    2015-01-01

    The acoustical cross-talk in row–column addressed 2-D transducer arrays for volumetric ultrasound imaging is investigated. Experimental results from a 2.7 MHz, λ/2-pitch capacitive micromachined ultrasonic transducer (CMUT) array with 62 rows and 62 columns are presented and analyzed in the frequ......The acoustical cross-talk in row–column addressed 2-D transducer arrays for volumetric ultrasound imaging is investigated. Experimental results from a 2.7 MHz, λ/2-pitch capacitive micromachined ultrasonic transducer (CMUT) array with 62 rows and 62 columns are presented and analyzed...

  1. Single VDTA Based Dual Mode Single Input Multioutput Biquad Filter

    Directory of Open Access Journals (Sweden)

    Rajeshwari Pandey

    2016-01-01

    Full Text Available This paper presents a dual mode, single input multioutput (SIMO biquad filter configuration using single voltage differencing transconductance amplifier (VDTA, three capacitors, and a grounded resistor. The proposed topology can be used to synthesize low pass (LP, high pass (HP, and band pass (BP filter functions. It can be configured as voltage mode (VM or current mode (CM structure with appropriate input excitation choice. The angular frequency (ω0 of the proposed structure can be controlled independently of quality factor (Q0. Workability of the proposed biquad configuration is demonstrated through PSPICE simulations using 0.18 μm TSMC CMOS process parameters.

  2. 1D multi-element CMUT arrays for ultrasound thermal therapy

    Science.gov (United States)

    N'Djin, William Apoutou; Canney, Michael; Meynier, Cyril; Chavrier, Françoise; Lafon, Cyril; Nguyen-Dinh, An; Chapelon, Jean-Yves; Carpentier, Alexandre

    2017-03-01

    Interstitial therapeutic ultrasound devices are a promising technology for performing thermal ablation in a wide variety of organs. In this study, the use of Capacitive Micromachined Ultrasound Transducers (CMUTs) for interstitial heating applications was investigated. CMUTs exhibit potential advantages for use in therapeutic ultrasound applications in comparison to standard piezo ultrasound transducer technologies as they have good characteristics in terms of miniaturization (cell size: few dozens of microns), bandwidth (several MHz) and high electro-acoustic efficiency. Two designs of CMUT arrays were studied: (1) a 1D 128-element planar-CMUT array originally dedicated to abdominal ultrasound imaging purposes (5 MHz, element size: 0.3 × 8.0 mm2); (2) a 12-element linear-array, 32.4-mm long and 0.8-mm wide, developed specifically for minimally-invasive interstitial therapeutic applications (6 MHz, element size: 2.7 × 0.8 mm2). Simulations were performed to evaluate the ability to generate thermal lesions in soft tissues with: (1) 1 single linear array, (2) a combination of multiple linear arrays positioned on a cylindrical catheter. Experimental investigations performed with the CMUT imaging array showed the ability to generate surface acoustic intensities (Iac) up to 20 W.cm-2 and to generate intense centimetric thermal lesions in in-vitro turkey breast tissues. At 6 MHz, a single element was able to generate in water a maximum peak pressure of >0.5 MPa. In simulations, the ability to use various power levels and frequencies on independent elements, as well as combinations of multiple linear-arrays offered sufficient flexibility to achieve a wide variety of thermal ablation patterns in 3D. Simulated ablation volumes could be controlled to cover accurately non-symmetrical volumes of brain metastases. In conclusion, CMUT arrays show interesting characteristics, which may open new perspectives of spatial control for conformal interstitial thermal therapy with

  3. Sensor Fusion Techniques for Phased-Array Eddy Current and Phased-Array Ultrasound Data

    Energy Technology Data Exchange (ETDEWEB)

    Arrowood, Lloyd F. [Y-12 National Security Complex, Oak Ridge, TN (United States)

    2018-03-15

    Sensor (or Data) fusion is the process of integrating multiple data sources to produce more consistent, accurate and comprehensive information than is provided by a single data source. Sensor fusion may also be used to combine multiple signals from a single modality to improve the performance of a particular inspection technique. Industrial nondestructive testing may utilize multiple sensors to acquire inspection data depending upon the object under inspection and the anticipated types of defects that can be identified. Sensor fusion can be performed at various levels of signal abstraction with each having its strengths and weaknesses. A multimodal data fusion strategy first proposed by Heideklang and Shokouhi that combines spatially scattered detection locations to improve detection performance of surface-breaking and near-surface cracks in ferromagnetic metals is shown using a surface inspection example and is then extended for volumetric inspections. Utilizing data acquired from an Olympus Omniscan MX2 from both phased array eddy current and ultrasound probes on test phantoms, single and multilevel fusion techniques are employed to integrate signals from the two modalities. Preliminary results demonstrate how confidence in defect identification and interpretation benefit from sensor fusion techniques. Lastly, techniques for integrating data into radiographic and volumetric imagery from computed tomography are described and results are presented.

  4. Volumetric ultrasound image-forming using fully controllable 2-D CMUT-on-ASIC arrays

    Science.gov (United States)

    Kim, Bae-Hyung; Song, Jongkeun; Lee, Seunghun; Cho, Kyungil; Kim, Youngil; Jeon, Taeho

    2013-03-01

    In real-time 3-D ultrasound imaging using 2-D array transducers, a large number of the 2-D array elements pose challenges in fabricating and transferring signals from/into the system. This fabrication problem has been solved by using a silicon micromachining process for capacitive micromachined ultrasonic transducer (CMUT) arrays. For realtime 3-D ultrasound imaging, manipulating massive ultrasound data acquired from a large number of system channels is a challenge as is fabricating and interconnecting hundreds or thousands of elements of 2-D array with the imaging system's front-end (FE) electronics. Minimizing the number of transmitting and receiving elements and the firing events without degrading the image quality is one of the solutions to reduce the overall system complexity and improve the frame rate. We have been developing a real-time 3-D volumetric ultrasound imaging system using 2-D CMUT arrays by integrating FE electronics with a large number of 2-D array elements. Here, we explore a configuration method to design a scalable 2-D CMUT array and a new volumetric image-formation method to provide higher information rate of a volume image. In this paper, we present the 2-D CMUT-on-ASIC arrays designed to reduce the overall system complexity, and a new volume scanning and image-forming method for real-time 3-D volumetric ultrasonic imaging using 2-D CMUT-on-ASIC arrays. To evaluate our works, we performed from theoretical studies for point spread functions of the array configuration to phantom experiments with off-the-line images.

  5. Diffraction and coherence in breast ultrasound tomography: a study with a toroidal array

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLL.; Duric, Neb [KCI; Littrup, Peter [KCI

    2008-01-01

    Ultrasound is commonly used as an adjunct to mammography for diagnostic evaluation of suspicions arising from breast cancer screening. As an alternative to conventional sonography that uses hand-held transducers, toroidal array probes that encircle the breast immersed in a water bath have been investigated for ultrasound tomography. In this paper, two sets of experiments performed with a prototype ultrasound scanner on a phantom and a human breast in vivo are used to investigate the effects of diffraction and coherence in ultrasound tomography. Reconstructions obtained with transmission diffraction tomography (TDT) are compared with conventional reflection imaging and computerized ultrasound tomography showing a substantial improvement. The in vivo tests demonstrate that TDT can image the complex boundary of a cancer mass and suggest that it can reveal the anatomy of milk ducts and Cooper's ligaments.

  6. Simulation Based Investigation of Focusing Phased Array Ultrasound in Dissimilar Metal Welds

    Directory of Open Access Journals (Sweden)

    Hun-Hee Kim

    2016-02-01

    Full Text Available Flaws at dissimilar metal welds (DMWs, such as reactor coolant systems components, Control Rod Drive Mechanism (CRDM, Bottom Mounted Instrumentation (BMI etc., in nuclear power plants have been found. Notably, primary water stress corrosion cracking (PWSCC in the DMWs could cause significant reliability problems at nuclear power plants. Therefore, phased array ultrasound is widely used for inspecting surface break cracks and stress corrosion cracks in DMWs. However, inspection of DMWs using phased array ultrasound has a relatively low probability of detection of cracks, because the crystalline structure of welds causes distortion and splitting of the ultrasonic beams which propagates anisotropic medium. Therefore, advanced evaluation techniques of phased array ultrasound are needed for improvement in the probability of detection of flaws in DMWs. Thus, in this study, an investigation of focusing and steering phased array ultrasound in DMWs was carried out using a time reversal technique, and an adaptive focusing technique based on finite element method (FEM simulation. Also, evaluation of focusing performance of three different focusing techniques was performed by comparing amplitude of phased array ultrasonic signals scattered from the targeted flaw with three different time delays.

  7. An Axial Array for Volumetric Intravascular Ultrasound Imaging

    NARCIS (Netherlands)

    Alles, E.J.

    2012-01-01

    Intravascular ultrasound (IVUS) is a medical imaging modality aimed at imaging blood vessel walls from within the vessel. Current commercial IVUS catheters are designed to yield two-dimensional cross-sectional images perpendicular to the vessel wall. By pulling the catheter back through the artery

  8. Volumetric ultrasound imaging using 2-D CMUT arrays.

    Science.gov (United States)

    Oralkan, Omer; Ergun, A Sanli; Cheng, Ching-Hsiang; Johnson, Jeremy A; Karaman, Mustafa; Lee, Thomas H; Khuri-Yakub, Butrus T

    2003-11-01

    Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-microm element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 x 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 x 16-element portion of the array to surrounding bondpads. An 8 x 16-element portion of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 x 4 group of elements in the middle of the 8 x 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for

  9. Reconfigurable 2D cMUT-ASIC arrays for 3D ultrasound image

    Science.gov (United States)

    Song, Jongkeun; Jung, Sungjin; Kim, Youngil; Cho, Kyungil; Kim, Baehyung; Lee, Seunghun; Na, Junseok; Yang, Ikseok; Kwon, Oh-kyong; Kim, Dongwook

    2012-03-01

    This paper describes the design and implementations of the complete 2D capacitive micromachined ultrasound transducer electronics and its analog front-end module for transmitting high voltage ultrasound pulses and receiving its echo signals to realize 3D ultrasound image. In order to minimize parasitic capacitances and ultimately improve signal-to- noise ratio (SNR), cMUT has to be integrate with Tx/Rx electronics. Additionally, in order to integrate 2D cMUT array module, significant optimized high voltage pulser circuitry, low voltage analog/digital circuit design and packaging challenges are required due to high density of elements and small pitch of each element. We designed 256(16x16)- element cMUT and reconfigurable driving ASIC composed of 120V high voltage pulser, T/R switch, low noise preamplifier and digital control block to set Tx frequency of ultrasound and pulse train in each element. Designed high voltage analog ASIC was successfully bonded with 2D cMUT array by flip-chip bonding process and it connected with analog front-end board to transmit pulse-echo signals. This implementation of reconfigurable cMUT-ASIC-AFE board enables us to produce large aperture 2D transducer array and acquire high quality of 3D ultrasound image.

  10. Reflections from Dual-Mode Alumni on the Differences between Distance and F2F Education

    Science.gov (United States)

    Firat, Mehmet

    2017-01-01

    The relevant literature is rich enough about the differences between distance and face to face education. However, the number of studies examining these differences from the viewpoint of dual-mode alumni, those graduated from both distance and face to face education programmes is limited. In this study, opinions of 33 dual-mode alumni from Turkey…

  11. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy

    Science.gov (United States)

    Hynynen, Kullervo; Jones, Ryan M.

    2016-01-01

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy. PMID:27494561

  12. Volumetric Ultrasound Imaging with Row-Column Addressed 2-D Arrays Using Spatial Matched Filter Beamforming

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Christiansen, Thomas Lehrmann

    2015-01-01

    For 3-D ultrasound imaging with row-column addressed 2-D arrays, the two orthogonal 1-D transmit and receive arrays are both used for one-way focusing in the lateral and elevation directions separately and since they are not in the same plane, the two-way focusing is the same as one-way focusing....... However, the achievable spatial resolution and contrast of the B-mode images in Delay and Sum (DAS) beamforming are limited by the aperture size and by the operating frequency. This paper, investigates Spatial Matched Filter (SMF) beamforming on row-column addressed 2-D arrays to increase spatial...

  13. Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imaging.

    Science.gov (United States)

    Sampaleanu, Alex; Zhang, Peiyu; Kshirsagar, Abhijeet; Moussa, Walied; Zemp, Roger J

    2014-02-01

    Two-dimensional ultrasound arrays hold great promise for 3-D imaging; however, wiring of each channel becomes impractical for large arrays or for small-footprint catheter probes for which the number of wires must be limited. Capacitive micromachined ultrasound transducers offer a promising solution for such 2-D array applications, but channel routing is still non-trivial. A top-orthogonal-to-bottom-electrode (TOBE) 2-D CMUT array architecture is presented along with row-column addressing schemes for low-channel-count 3-D ultrasound imaging. An N × N TOBE array is capable of obtaining 3-D images using only 2N channels. An interfacing scheme is presented in which transmit-receive signals are routed along rows while bias voltages are applied along columns, effectively allowing for single-element transmit/receive control. Simulations demonstrated potentially finer resolution and improved side lobe suppression over a previously published row-column-based imaging method. Laser vibrometer testing was done to measure membrane displacement in air and confirmed that single-element air-coupled actuation in transmit mode could be achieved using our proposed interfacing scheme. Acoustic testing was also performed in both transmit and receive modes to characterize the ability of the proposed interfacing scheme to achieve dominant-element transmission and reception in immersion operation. It was seen that membrane displacement in both modes was indeed largely confined to the active area.

  14. In Vivo Evaluations of a Phased Ultrasound Array for Transesophageal Cardiac Ablation

    Science.gov (United States)

    Jaiswal, Devina; Werner, Jacob; Park, Eun-Joo; Francischelli, David; Smith, Nadine Barrie

    2010-03-01

    Atrial fibrillation is one of the most common arrhythmias that affects over 2.2 million Americans each year. Catheter ablation, one of the effective treatments, has shown high rate of success in treating paroxysmal atrial fibrillation. Currently, radiofrequency which is being used for catheter ablation is an invasive procedure. Measurable morbidity and significant costs and time are associated with this modality of treatment of permanent or persistent atrial fibrillation. In order to address these issues, a transesophageal ultrasound applicator for noninvasive cardiac ablation was designed, developed and evaluated. The ultrasound energy delivered by the phased array was used to create a lesion in the myocardial tissue. Various factors, simulation results of transducer arrays, current transesophageal medical devices, and throat anatomy, were considered while designing a phased ultrasound transducer that can be inserted into the esophagus. For this research, a two-dimensional sparse phased array with flat tapered elements was fabricated and evaluated in in vivo experiments. Five pigs were anesthetized; the array was passed transesophagealy and positioned over the heart. An operating frequency of 1.6 MHz and 8˜15 minutes of array operation resulted in both single and multiple lesions on atrial and ventricular myocardium. The average size of lesions was 5.1±2.1 mm in diameter and 7.8±2.5 mm in length. Experimental results indicate that the array delivered sufficient power to produce ablation at the focal point while not grossly damaging the tissue surrounding the area of interest. These results demonstrate a potential application of the ultrasound applicator for noninvasive transesophageal cardiac surgery in atrial fibrillation treatment.

  15. 2D sparse array transducer optimization for 3D ultrasound imaging

    International Nuclear Information System (INIS)

    Choi, Jae Hoon; Park, Kwan Kyu

    2014-01-01

    A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.

  16. SOUND-SPEED TOMOGRAPHY USING FIRST-ARRIVAL TRANSMISSION ULTRASOUND FOR A RING ARRAY

    Energy Technology Data Exchange (ETDEWEB)

    HUANG, LIANJIE [Los Alamos National Laboratory; QUAN, YOULI [Los Alamos National Laboratory

    2007-01-31

    Sound-speed tomography images can be used for cancer detection and diagnosis. Tumors have generally higher sound speeds than the surrounding tissue. Quality and resolution of tomography images are primarily determined by the insonification/illumination aperture of ultrasound and the capability of the tomography method for accurately handling heterogeneous nature of the breast. We investigate the capability of an efficient time-of-flight tomography method using transmission ultrasound from a ring array for reconstructing sound-speed images of the breast. The method uses first arrival times of transmitted ultrasonic signals emerging from non-beamforming ultrasound transducers located around a ring. It properly accounts for ray bending within the breast by solving the eikonal equation using a finite-difference scheme. We test and validate the time-of-flight transmission tomography method using synthetic data for numerical breast phantoms containing various objects. In our simulation, the objects are immersed in water within a ring array. Two-dimensional synthetic data are generated using a finite-difference scheme to solve acoustic-wave equation in heterogeneous media. We study the reconstruction accuracy of the tomography method for objects with different sizes and shapes as well as different perturbations from the surrounding medium. In addition, we also address some specific data processing issues related to the tomography. Our tomography results demonstrate that the first-arrival transmission tomography method can accurately reconstruct objects larger than approximately five wavelengths of the incident ultrasound using a ring array.

  17. Synthetic Aperture Beamforming in Ultrasound using Moving Arrays

    DEFF Research Database (Denmark)

    Andresen, Henrik

    Medical ultrasound (US) is widely used because it allows cheap real-time imaging of soft tissue with no known side-effects or hazards to either patients or operating personnel. US has existed since the 1960s and was originally adapted from the concept of radar and sonar. The development......-dimensional and the limited view makes diagnosis of pathology difficult [1]. A full 3D volume acquisition makes it possible to capture larger areas at once, and also allows complete freedom in choosing the slice to view after the scan has been completed. This removes the need for doing additional scans if a significant slice...... resolution. A challenge with SAF is a large increase in processing requirements, especially for 3D systems. Ideally the method is able to achieve a good image quality for all depths in the volume with a time-resolution fast enough for cardiac images. This will allow better diagnoses with fewer scans, making...

  18. Design and evaluation of a feedback based phased array system for ultrasound surgery.

    Science.gov (United States)

    Daum, D R; Buchanan, M T; Fjield, T; Hynynen, K

    1998-01-01

    A driving system has been designed for phased array ultrasound applicators. The system is designed to-operate in the bandwidth 1.2 to 1.8 MHz, with independent channel power control up to 60 W (8 bit resolution) for each array element. To reduce power variation between elements, the system utilizes switching regulators in a feedback loop to automatically adjust the DC supply of a class D/E power converter. This feedback reduces the RF electrical power variation from 20% to 1% into a 16 element array. DC-to-RF efficiencies close to 70% for all power levels eliminates the need for large heat sinks. In addition to power control, each channel may be phase shifted 360 degrees with a minimum of 8 bit resolution. To ensure proper operation while driving ultrasound arrays with varying element sizes, each RF driving channel implements phase feedback such that proper phase of the driving signal is produced either at the amplifier output before the matching circuitry or after the matching circuitry at the transducer face. This feedback has been experimentally shown to increase the focal intensities by 20 to 25% of two tested phased arrays without array calibration using a hydrophone.

  19. Ultrasound therapy transducers with space-filling non-periodic arrays.

    Science.gov (United States)

    Raju, Balasundar I; Hall, Christopher S; Seip, Ralf

    2011-05-01

    Ultrasound transducers designed for therapeutic purposes such as tissue ablation, histotripsy, or drug delivery require large apertures for adequate spatial localization while providing sufficient power and steerability without the presence of secondary grating lobes. In addition, it is highly preferred to minimize the total number of channels and to maintain simplicity in electrical matching network design. To this end, we propose array designs that are both space-filling and non-periodic in the placement of the elements. Such array designs can be generated using the mathematical concept of non-periodic or aperiodic tiling (tessellation) and can lead to reduced grating lobes while maintaining full surface area coverage to deliver maximum power. For illustration, we designed two 2-D space-filling therapeutic arrays with 128 elements arranged on a spherical shell. One was based on the two-shape Penrose rhombus tiling, and the other was based on a single rectangular shape arranged non-periodically. The steerability performance of these arrays was studied using acoustic field simulations. For comparison, we also studied two other arrays, one with circular elements distributed randomly, and the other a periodic array with square elements. Results showed that the two space-filling non-periodic arrays were able to steer to treat a volume of 16 x 16 x 20 mm while ensuring that the grating lobes were under -10 dB compared with the main lobe. The rectangular non-periodic array was able to generate two and half times higher power than the random circles array. The rectangular array was then fabricated by patterning the array using laser scribing methods and its steerability performance was validated using hydrophone measurements. This work demonstrates that the concept of space-filling aperiodic/non-periodic tiling can be used to generate therapy arrays that are able to provide higher power for the same total transducer area compared with random arrays while maintaining

  20. Comparison of 3-D Synthetic Aperture Phased-Array Ultrasound Imaging and Parallel Beamforming

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Jensen, Jørgen Arendt

    2014-01-01

    This paper demonstrates that synthetic apertureimaging (SAI) can be used to achieve real-time 3-D ultra-sound phased-array imaging. It investigates whether SAI in-creases the image quality compared with the parallel beam-forming (PB) technique for real-time 3-D imaging. Data areobtained using both...... simulations and measurements with anultrasound research scanner and a commercially available 3.5-MHz 1024-element 2-D transducer array. To limit the probecable thickness, 256 active elements are used in transmit andreceive for both techniques. The two imaging techniques weredesigned for cardiac imaging, which...

  1. In vivo visualization of robotically implemented synthetic tracked aperture ultrasound (STRATUS) imaging system using curvilinear array

    Science.gov (United States)

    Zhang, Haichong K.; Aalamifar, Fereshteh; Boctor, Emad M.

    2016-04-01

    Synthetic aperture for ultrasound is a technique utilizing a wide aperture in both transmit and receive to enhance the ultrasound image quality. The limitation of synthetic aperture is the maximum available aperture size limit determined by the physical size of ultrasound probe. We propose Synthetic-Tracked Aperture Ultrasound (STRATUS) imaging system to overcome the limitation by extending the beamforming aperture size through ultrasound probe tracking. With a setup involving a robotic arm, the ultrasound probe is moved using the robotic arm, while the positions on a scanning trajectory are tracked in real-time. Data from each pose are synthesized to construct a high resolution image. In previous studies, we have demonstrated the feasibility through phantom experiments. However, various additional factors such as real-time data collection or motion artifacts should be taken into account when the in vivo target becomes the subject. In this work, we build a robot-based STRATUS imaging system with continuous data collection capability considering the practical implementation. A curvilinear array is used instead of a linear array to benefit from its wider capture angle. We scanned human forearms under two scenarios: one submerged the arm in the water tank under 10 cm depth, and the other directly scanned the arm from the surface. The image contrast improved 5.51 dB, and 9.96 dB for the underwater scan and the direct scan, respectively. The result indicates the practical feasibility of STRATUS imaging system, and the technique can be potentially applied to the wide range of human body.

  2. Dual-mode Propulsion System Enabling CubeSat Exploration of the Solar System

    Data.gov (United States)

    National Aeronautics and Space Administration — Researchers at the Center for Space Nuclear Research (CSNR) are proposing a radioisotope-based, dual-mode, low mass propulsion system for a CubeSat payload capable...

  3. SPHERICAL COVERAGE DUAL MODE SENSOR FOR UAS SEPARATION ASSURANCE, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposed is a dual-mode sensor for use aboard unmanned aircraft for safe operation in the NAS that: 1. Incorporates high resolution Millimeter Wave radar with high...

  4. Design of a dual-mode electrochemical measurement and analysis system.

    Science.gov (United States)

    Yang, Jr-Fu; Wei, Chia-Ling; Wu, Jian-Fu; Liu, Bin-Da

    2013-01-01

    A dual-mode electrochemical measurement and analysis system is proposed. This system includes a dual-mode chip, which was designed and fabricated by using TSMC 0.35 µm 3.3 V/5 V 2P4M mixed-signal CMOS process. Two electrochemical measurement and analysis methods, chronopotentiometry and voltammetry, can be performed by using the proposed chip and system. The proposed chip and system are verified successfully by performing voltammetry and chronopotentiometry on solutions.

  5. Fast computation of far-field pulse-echo PSF of arbitrary arrays for large sparse 2-D ultrasound array design.

    Science.gov (United States)

    Li, Zhaohui; Chi, Cheng

    2018-03-01

    Large wideband two-dimensional (2-D) arrays are essential for high-resolution three-dimensional (3-D) ultrasound imaging. Since the tremendous element number of a full sampled large 2-D array is not affordable in any practical 3-D ultrasound imaging system, it is necessary to reduce the element number through sparse 2-D array design. Sparse array design requires that both the positions and weights of the array elements should be arbitrarily alterable. Hence a proper evaluation tool that can deal with arbitrary array is integral to optimizing the array structure and apodization function. It is known that pulse-echo point spread function (PSF) has been a common tool used to evaluate the performance of wideband arrays in ultrasound imaging all along, which also plays an important role in wideband ultrasound simulations. However, so far the conventional ultrasound simulation tools can only calculate pulse-echo PSF of arbitrary wideband arrays in the time domain because of the existence of nonuniform nodes in the spatial impulse response expressions, which obstructs their application of FFT to do fast computation of the time-domain convolutions. As a result, ultra-high time consumption of pulse-echo PSF computation of a large arbitrary wideband array hampers it to be taken as the evaluation tool by any stochastic optimization methods which need massive iterations in designing large sparse 2-D arrays. This paper aims to make available the pulse-echo PSF tool in designing large sparse 2-D arrays by proposing a fast computation method of far-field pulse-echo PSFs of arbitrary wideband arrays. In the paper, fast computation of wideband spatial impulse responses of a 2-D array is first realized in frequency domain by employing the nonuniform fast Fourier transform (NUFFT), under the point source assumption in far-field. On the basis of that, fast computation of time-domain convolutions is made possible by using FFT. In addition, a short inverse FFT (IFFT) is applied in

  6. Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system.

    Science.gov (United States)

    Morgan, C L; Trought, W S; von Ramm, O T; Thurstone, F L

    1980-05-01

    Abdominal and obstetric applications of a dynamically focused phased array real time ultrasonic system are described. This work was performed utilising both the Thaumascan (two-dimensional, high resolution, actual time, ultrasound, multi-element array scanner) and the first commercial unit based on this system, the Grumman RT-400. Examples of normal and pathological anatomy are presented from over 300 examinations performed to date, including a series of 28 abdominal aortic aneurysms studied with the RT-400. Following electronic alterations in the Thaumascan with resultant improvement in the grey scale, prospective analyses in 86 obstetric and 23 abdominal examinations were undertaken. These studies indicate that fetal, intra-uterine, and abdominal structures can be rapidly and consistently imaged. The value of real time ultrasonic scanning in obstetric and abdominal examinations is illustrated. The principles of dynamically focused phased arrays are described, and the merits and limitations of these systems are discussed.

  7. Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging.

    Science.gov (United States)

    Wygant, Ira O; Zhuang, Xuefeng; Yeh, David T; Oralkan, Omer; Sanli Ergun, A; Karaman, Mustafa; Khuri-Yakub, Butrus T

    2008-02-01

    For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse echo operation, the average - 6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 mPa/pHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.

  8. A dual-mode human computer interface combining speech and tongue motion for people with severe disabilities.

    Science.gov (United States)

    Huo, Xueliang; Park, Hangue; Kim, Jeonghee; Ghovanloo, Maysam

    2013-11-01

    We are presenting a new wireless and wearable human computer interface called the dual-mode Tongue Drive System (dTDS), which is designed to allow people with severe disabilities to use computers more effectively with increased speed, flexibility, usability, and independence through their tongue motion and speech. The dTDS detects users' tongue motion using a magnetic tracer and an array of magnetic sensors embedded in a compact and ergonomic wireless headset. It also captures the users' voice wirelessly using a small microphone embedded in the same headset. Preliminary evaluation results based on 14 able-bodied subjects and three individuals with high level spinal cord injuries at level C3-C5 indicated that the dTDS headset, combined with a commercially available speech recognition (SR) software, can provide end users with significantly higher performance than either unimodal forms based on the tongue motion or speech alone, particularly in completing tasks that require both pointing and text entry.

  9. TOPICAL REVIEW: Capacitive micromachined ultrasonic transducer arrays for minimally invasive medical ultrasound

    Science.gov (United States)

    Chen, Jingkuang

    2010-02-01

    This paper reviews the minimally invasive capacitive micromachined ultrasonic transducer (CMUT) arrays for medical diagnosis and therapy. While piezoelectric transducers dominate today's medical ultrasound market, the capacitive micromachined ultrasonic transducer has recently emerged as a promising alternative which delivers a comparable device performance to its piezoelectric counterparts, is compatible with front-end circuit integration, allows high-density imager integration and is relative easy in miniaturization. Utilizing MEMS technology, the substrate of CMUT arrays can be micromachined into miniature platforms with various geometrical shapes, which include needles, three-dimensional prisms, as well as other flexible-substrate configurations. These arrays are useful for reaching deep inside the tissue or an organ with a minimally invasive approach. Due to the close proximity of the transducers to the target organ/tissue, a higher resolution/accuracy of diagnostic information can be achieved. In addition to pulse-echo and photoacoustic imaging, high-power CMUT devices capable of delivering ultrasounds with a pressure greater than 1.0 MPa have been monolithically integrated with imager CMUTs for image-guided therapy (IGT). Such miniature devices would facilitate diagnostic and therapy interventions not possible with conventional piezoelectric transducers.

  10. 2D array transducers for real-time 3D ultrasound guidance of interventional devices

    Science.gov (United States)

    Light, Edward D.; Smith, Stephen W.

    2009-02-01

    We describe catheter ring arrays for real-time 3D ultrasound guidance of devices such as vascular grafts, heart valves and vena cava filters. We have constructed several prototypes operating at 5 MHz and consisting of 54 elements using the W.L. Gore & Associates, Inc. micro-miniature ribbon cables. We have recently constructed a new transducer using a braided wiring technology from Precision Interconnect. This transducer consists of 54 elements at 4.8 MHz with pitch of 0.20 mm and typical -6 dB bandwidth of 22%. In all cases, the transducer and wiring assembly were integrated with an 11 French catheter of a Cook Medical deployment device for vena cava filters. Preliminary in vivo and in vitro testing is ongoing including simultaneous 3D ultrasound and x-ray fluoroscopy.

  11. Photoacoustic imaging of brachytherapy seeds using a channel-domain ultrasound array system

    Science.gov (United States)

    Harrison, Tyler; Zemp, Roger J.

    2011-03-01

    Brachytherapy is a technique commonly used in the treatment of prostate cancer that relies on the precise placement of small radioactive seeds near the tumor location. The advantage of this technique over traditional radiation therapies is that treatment can be continuous and uniform, resulting in fewer clinic visits and a shorter treatment duration. Two important phases of this treatment are needle guidance for implantation, and post-placement verification for dosimetry. Ultrasound is a common imaging modality used for these purposes, but it can be difficult to distinguish the seeds from surrounding tissues, often requiring other imaging techniques such as MRI or CT. Photoacoustic imaging may offer a viable alternative. Using a photoacoustic system based on an L7- 4 array transducer and a realtime ultrasound array system capable of parallel channel data acquisition streamed to a multi-core computer via PCI-express, we have demonstrated imaging of these seeds at an ultrasound depth of 16 mm and laser penetration depths ranging up to 50 mm in chicken tissue with multiple optical wavelengths. Ultrasound and photoacoustic images are coregistered via an interlaced pulse sequence. Two laser pulses are used to form a photoacoustic image, and at these depths, the brachytherapy seeds are detected with a signal-to-noise ratio of over 26dB. To obtain this result, 1064nm light was used with a fluence of 100mJ/cm2, the ANSI limit for human skin exposure at this wavelength. This study demonstrates the potential for photoacoustic imaging as a candidate technology for brachytherapy seed placement guidance and verification.

  12. MR thermometry characterization of a hyperthermia ultrasound array designed using the k-space computational method

    Directory of Open Access Journals (Sweden)

    Lee Hotaik

    2006-10-01

    Full Text Available Abstract Background Ultrasound induced hyperthermia is a useful adjuvant to radiation therapy in the treatment of prostate cancer. A uniform thermal dose (43°C for 30 minutes is required within the targeted cancerous volume for effective therapy. This requires specific ultrasound phased array design and appropriate thermometry method. Inhomogeneous, acoustical, three-dimensional (3D prostate models and economical computational methods provide necessary tools to predict the appropriate shape of hyperthermia phased arrays for better focusing. This research utilizes the k-space computational method and a 3D human prostate model to design an intracavitary ultrasound probe for hyperthermia treatment of prostate cancer. Evaluation of the probe includes ex vivo and in vivo controlled hyperthermia experiments using the noninvasive magnetic resonance imaging (MRI thermometry. Methods A 3D acoustical prostate model was created using photographic data from the Visible Human Project®. The k-space computational method was used on this coarse grid and inhomogeneous tissue model to simulate the steady state pressure wavefield of the designed phased array using the linear acoustic wave equation. To ensure the uniformity and spread of the pressure in the length of the array, and the focusing capability in the width of the array, the equally-sized elements of the 4 × 20 elements phased array were 1 × 14 mm. A probe was constructed according to the design in simulation using lead zerconate titanate (PZT-8 ceramic and a Delrin® plastic housing. Noninvasive MRI thermometry and a switching feedback controller were used to accomplish ex vivo and in vivo hyperthermia evaluations of the probe. Results Both exposimetry and k-space simulation results demonstrated acceptable agreement within 9%. With a desired temperature plateau of 43.0°C, ex vivo and in vivo controlled hyperthermia experiments showed that the MRI temperature at the steady state was 42.9 ± 0.38

  13. Design and Implementation of Dual-Mode Wireless Video Monitoring System

    Directory of Open Access Journals (Sweden)

    BAO Song-Jian

    2014-10-01

    Full Text Available Dual-mode wireless video transmission has two major problems. Firstly, one is time delay difference bringing about asynchronous reception decoding frame error phenomenon; secondly, dual-mode network bandwidth inconformity causes scheduling problem. In order to solve above two problems, a kind of TD-SCDMA/CDMA20001x dual-mode wireless video transmission design method is proposed. For the solution of decoding frame error phenomenon, the design puts forward adding frame identification and packet preprocessing at the sending and synchronizing combination at the receiving end. For the solution of scheduling problem, the wireless communication channel cooperative work and video data transmission scheduling management algorithm is proposed in the design.

  14. A random phased array device for delivery of high intensity focused ultrasound

    International Nuclear Information System (INIS)

    Hand, J W; Shaw, A; Sadhoo, N; Rajagopal, S; Dickinson, R J; Gavrilov, L R

    2009-01-01

    Randomized phased arrays can offer electronic steering of a single focus and simultaneous multiple foci concomitant with low levels of secondary maxima and are potentially useful as sources of high intensity focused ultrasound (HIFU). This work describes laboratory testing of a 1 MHz random phased array consisting of 254 elements on a spherical shell of radius of curvature 130 mm and diameter 170 mm. Acoustic output power and efficiency are measured for a range of input electrical powers, and field distributions for various single- and multiple-focus conditions are evaluated by a novel technique using an infrared camera to provide rapid imaging of temperature changes on the surface of an absorbing target. Experimental results show that the array can steer a single focus laterally to at least ±15 mm off axis and axially to more than ±15 mm from the centre of curvature of the array and patterns of four and five simultaneous foci ±10 mm laterally and axially whilst maintaining low intensity levels in secondary maxima away from the targeted area in good agreement with linear theoretical predictions. Experiments in which pork meat was thermally ablated indicate that contiguous lesions several cm 3 in volume can be produced using the patterns of multiple foci.

  15. Phased Array Ultrasound System for Planar Flow Mapping in Liquid Metals.

    Science.gov (United States)

    Mader, Kevin; Nauber, Richard; Galindo, Vladimir; Beyer, Hannes; Buttner, Lars; Eckert, Sven; Czarske, Jurgen

    2017-09-01

    Controllable magnetic fields can be used to optimize flows in technical and industrial processes involving liquid metals in order to improve quality and yield. However, experimental studies in magnetohydrodynamics often involve complex, turbulent flows and require planar, two-component (2c) velocity measurements through only one acoustical access. We present the phased array ultrasound Doppler velocimeter as a modular research platform for flow mapping in liquid metals. It combines the pulse wave Doppler method with the phased array technique to adaptively focus the ultrasound beam. This makes it possible to resolve smaller flow structures in planar measurements compared with fixed-beam sensors and enables 2c flow mapping with only one acoustical access via the cross beam technique. From simultaneously measured 2-D velocity fields, quantities for turbulence characterization can be derived. The capabilities of this measurement system are demonstrated through measurements in the alloy gallium-indium-tin at room temperature. The 2-D, 2c velocity measurements of a flow in a cubic vessel driven by a rotating magnetic field (RMF) with a spatial resolution of up to 2.2 mm are presented. The measurement results are in good agreement with a semianalytical simulation. As a highlight, two-point correlation functions of the velocity field for different magnitudes of the RMF are presented.

  16. The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study

    International Nuclear Information System (INIS)

    Pajek, Daniel; Hynynen, Kullervo

    2012-01-01

    High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1–1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum –3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke. (paper)

  17. Conformal Bulk Ablation And Therapy Monitoring Using Intracorporeal Image-Treat Ultrasound Arrays

    Science.gov (United States)

    Makin, I. R.; Faidi, W.; Mast, T. D.; Runk, M.; Slayton, M.; Barthe, P.

    2005-03-01

    For thermal treatment of soft tissue, an alternative to HIFU is bulk ablation using unfocused or weakly focused intense ultrasound fields. This approach offers faster ablation of large tissue volumes and can be performed in minimally invasive (e.g., laparoscopic or percutaneous) procedures. Here, methods for image-guided ablation of large tissue volumes using compact dual-modality (image and treat) ultrasound arrays are reported including tissue modification caused by the thermal therapy. The dual-modality arrays developed have 16-64 elements spanning apertures of 2-8 mm in elevation and 24-48 mm in azimuth. These devices can provide both therapeutically significant power (e.g. source intensity > 80 W/cm2 at 3.1 MHz) and broad bandwidth (e.g. 50% with a center frequency of 3.5 MHz) for imaging. Imaging challenges associated with limited probe dimensions and channel count are met using signal processing techniques that improve definition and contrast, allowing high-quality B-scan images and useful monitoring information to be obtained during therapy planning and treatment. Using linear and rotational scanning methods, large tissue volumes (20-60 cc) can be treated. The approach can be applied for ablation of other soft tissue pathologies, e.g., kidney, heart, uterus, brain, GI tract, etc.

  18. Multi-Focus Beamforming for Thermal Strain Imaging Using a Single Ultrasound Linear Array Transducer.

    Science.gov (United States)

    Nguyen, Man M; Ding, Xuan; Leers, Steven A; Kim, Kang

    2017-06-01

    Ultrasound-induced thermal strain imaging (TSI) has been used successfully to identify lipid- and water-based tissues in atherosclerotic plaques in some research settings. However, TSI faces several challenges to be realized in clinics. These challenges include motion artifacts and displacement tracking accuracy, as well as limited heating capability, which contributes to low thermal strain signal-to-noise ratio, and a limited field of view. Our goal was to address the challenge in heating tissue in TSI. Current TSI systems use separate heating and imaging transducers, which require physical alignment of the heating and imaging beams and result in a bulky setup that limits in vivo operation. We evaluated a new design for heating beams that can be implemented on a linear array imaging transducer and can provide improved heating area and efficiency as compared with previous implementations. The heating beams designed were implemented with a clinical linear array imaging transducer connected to a research ultrasound platform. In vitro experiments using tissue-mimicking phantoms with no blood flow revealed that the new design resulted in an effective heating area of approximately 0.85 cm 2 and a 0.3°C temperature rise in 2 s of heating, which compared well with in silico finite-element simulations. With the new heating beams, TSI was found to be able to detect a lipid-mimicking rubber inclusion with a diameter of 1 cm from the water-based gelatin background, with a strain contrast of 2.3 (+0.14% strain in the rubber inclusion and -0.06% strain in the gelatin background). Lastly, lipid-based tissue in a 1-cm-diameter human carotid endarterectomy (CEA) sample was identified in good agreement with histology. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Basic study on ultrasonic monitoring using 1.5-dimensional ultrasound phased array for ultrasound-guided high-intensity focused ultrasound treatment

    Science.gov (United States)

    Takagi, Ryo; Iwasaki, Ryosuke; Tomiyasu, Kentaro; Yoshizawa, Shin; Umemura, Shin-ichiro

    2017-07-01

    We have been studying a real-time detection method for tissue changes induced by high-intensity focused ultrasound (HIFU) treatment using ultrasonic RF signals. It has been difficult to track the target region when the tissue to be treated deviates from the imaging plane along the elevation axis of the probe. In this study, a new 1.5-dimensional (1.5D) prototype phased array probe consisting of transducer elements along both the lateral and elevation axes was developed to track tissue motion along the elevation axis of the probe, and the elevational displacement range where the tracking is effective was investigated. The complex cross-correlation coefficient based on a block matching algorithm was applied to 2.5D volumetric RF images acquired by the 1.5D probe and the displacement vector along the elevation axis was calculated. From the results, it was found that the effective tracking range using this prototype probe was up to 3 mm, about 3 times that of a conventional 1D imaging probe. The proposed 1.5D phased array probe has the potential to track target tissue with intrafractional motion.

  20. A Dual-Mode UWB Wireless Platform with Random Pulse Length Detection for Remote Patient Monitoring

    DEFF Research Database (Denmark)

    Reyes, Carlos; Bisbe, Sergi; Shen, Ming

    2013-01-01

    This paper presents a dual-mode ultra-wideband platform for wireless Remote Patient Monitoring (RPM). Existing RPM solutions are typically based on two different hardware platforms; one responsible for medical-data monitoring and one to handle data transmission. The proposed RPM topology is based...

  1. Dual mode cobaloxime crystals: Acceleration of trans-cis photochromic reaction rate by photoisomerization

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, Akiko, E-mail: asekine@chem.titech.ac.jp [Department of Chemistry and Materials Science, Graduate School of Science and Engineering, Tokyo Institute of Technology, O-okayama, Meguro-ku, Tokyo 152-8551 (Japan)

    2016-08-26

    Our recent results on the photochromic reactions in dual mode cobaloxime crystals containing azobenzene derivatives are briefly reviewed. This work represents the first step toward the design of functional materials which can be controlled by two independent external stimuli, one by visible light and the other by UV radiation.

  2. Active power filter for harmonic compensation using a digital dual-mode-structure repetitive control approach

    DEFF Research Database (Denmark)

    Zou, Zhixiang; Wang, Zheng; Cheng, Ming

    2012-01-01

    This paper presents an digital dual-mode-structure repetitive control approach for the single-phase shunt active power filter (APF), which aims to enhance the tracking ability and eliminate arbitrary order harmonic. The proposed repetitive control scheme blends the characteristics of both odd-har...

  3. 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Jensen, Jørgen Arendt

    2013-01-01

    -lobe levels are higher for the row-column addressed array. The cystic resolution sampled at a relative intensity difference of 20 dB shows a cyst size of 5.00mm for the row-column addressed array and 2.39mm for the fully sampled array. A simulation study is carried out which compares how the imaging quality...... is 510% larger than when row-column addressing the array. The cyst radius needed to achieve -20 dB intensity in the cyst is 396% larger for the fully addressed array compared to the row-column addressed array. The measurements were made using the experimental ultrasound scanner SARUS and a 32x32 element...

  4. In vivo imaging of inducible tyrosinase gene expression with an ultrasound array-based photoacoustic system

    Science.gov (United States)

    Harrison, Tyler; Paproski, Robert J.; Zemp, Roger J.

    2012-02-01

    Tyrosinase, a key enzyme in the production of melanin, has shown promise as a reporter of genetic activity. While green fluorescent protein has been used extensively in this capacity, it is limited in its ability to provide information deep in tissue at a reasonable resolution. As melanin is a strong absorber of light, it is possible to image gene expression using tyrosinase with photoacoustic imaging technologies, resulting in excellent resolutions at multiple-centimeter depths. While our previous work has focused on creating and imaging MCF-7 cells with doxycycline-controlled tyrosinase expression, we have now established the viability of these cells in a murine model. Using an array-based photoacoustic imaging system with 5 MHz center frequency, we capture interleaved ultrasound and photoacoustic images of tyrosinase-expressing MCF-7 tumors both in a tissue mimicking phantom, and in vivo. Images of both the tyrosinase-expressing tumor and a control tumor are presented as both coregistered ultrasound-photoacoustic B-scan images and 3-dimensional photoacoustic volumes created by mechanically scanning the transducer. We find that the tyrosinase-expressing tumor is visible with a signal level 12dB greater than that of the control tumor in vivo. Phantom studies with excised tumors show that the tyrosinase-expressing tumor is visible at depths in excess of 2cm, and have suggested that our imaging system is sensitive to a transfection rate of less than 1%.

  5. SUPER-RESOLUTION ULTRASOUND TOMOGRAPHY: A PRELIMINARY STUDY WITH A RING ARRAY

    Energy Technology Data Exchange (ETDEWEB)

    HUANG, LIANJIE [Los Alamos National Laboratory; SIMONETTI, FRANCESCO [NON LANL; DURIC, NEBOJSA [NON LANL; RAMA, OLSI [NON LANL

    2007-01-18

    Ultrasound tomography attempts to retrieve the structure of an objective by exploiting the interaction of acoustic waves with the object. A fundamental limit of ultrasound tomography is that features cannot be resolved if they are spaced less than {lambda}/2 apart, where {lambda} is wavelength of the probing wave, regardless of the degree of accuracy of the measurements. Therefore, since the attenuation of the probing wave with propagation distance increases as {lambda} decreases, resolution has to be traded against imaging depth. Recently, it has been shown that the {lambda}/2 limit is a consequence of the Born approximation (implicit in the imaging algorithms currently employed) which neglects the distortion of the probing wavefield as it travels through the medium to be imaged. On the other hand, such a distortion, which is due to the multiple scattering phenomenon, can encode unlimited resolution in the radiating component of the scattered field. Previously, a resolution better than {lambda}/3 has been reported in these proceedings [F. Simonetti, pp. 126 (2006)] in the case of elastic wave probing. In this paper, they demonstrate experimentally a resolution better than {lambda}/4 for objects immersed in a water bth probed by means of a ring array which excites and detects pressure waves in a full view configuration.

  6. Integrated circuits for volumetric ultrasound imaging with 2-D CMUT arrays.

    Science.gov (United States)

    Bhuyan, Anshuman; Choe, Jung Woo; Lee, Byung Chul; Wygant, Ira O; Nikoozadeh, Amin; Oralkan, Ömer; Khuri-Yakub, Butrus T

    2013-12-01

    Real-time volumetric ultrasound imaging systems require transmit and receive circuitry to generate ultrasound beams and process received echo signals. The complexity of building such a system is high due to requirement of the front-end electronics needing to be very close to the transducer. A large number of elements also need to be interfaced to the back-end system and image processing of a large dataset could affect the imaging volume rate. In this work, we present a 3-D imaging system using capacitive micromachined ultrasonic transducer (CMUT) technology that addresses many of the challenges in building such a system. We demonstrate two approaches in integrating the transducer and the front-end electronics. The transducer is a 5-MHz CMUT array with an 8 mm × 8 mm aperture size. The aperture consists of 1024 elements (32 × 32) with an element pitch of 250 μm. An integrated circuit (IC) consists of a transmit beamformer and receive circuitry to improve the noise performance of the overall system. The assembly was interfaced with an FPGA and a back-end system (comprising of a data acquisition system and PC). The FPGA provided the digital I/O signals for the IC and the back-end system was used to process the received RF echo data (from the IC) and reconstruct the volume image using a phased array imaging approach. Imaging experiments were performed using wire and spring targets, a ventricle model and a human prostrate. Real-time volumetric images were captured at 5 volumes per second and are presented in this paper.

  7. Theoretical characterization of annular array as a volumetric optoacoustic ultrasound handheld probe

    Science.gov (United States)

    Kalkhoran, Mohammad Azizian; Vray, Didier

    2018-02-01

    Optoacoustic ultrasound (OPUS) is a promising hybridized technique for simultaneous acquisition of functional and morphological data. The optical specificity of optoacoustic leverages the diagnostic aptitude of ultrasonography beyond anatomy. However, this integration has been rarely practiced for volumetric imaging. The challenge lies in the effective imaging probes that preserve the functionality of both modalities. The potentials of a sparse annular array for volumetric OPUS imaging are theoretically investigated. In order to evaluate and optimize the performance characteristics of the probe, series of analysis in the framework of system model matrix was carried out. The two criteria of voxel crosstalk and eigenanalysis have been employed to unveil information about the spatial sensitivity, aliasing, and number of definable spatial frequency components. Based on these benchmarks, the optimal parameters for volumetric handheld probe are determined. In particular, the number, size, and the arrangement of the elements and overall aperture dimension were investigated. The result of the numerical simulation suggests that the segmented-annular array of 128 negatively focused elements with 1λ × 20λ size, operating at 5-MHz central frequency showcases a good agreement with the physical requirement of both imaging systems. We hypothesize that these features enable a high-throughput volumetric passive/active ultrasonic imaging system with great potential for clinical applications.

  8. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  9. Focusing of high intensity ultrasound through the rib cage using a therapeutic random phased array

    Science.gov (United States)

    Bobkova, Svetlana; Gavrilov, Leonid; Khokhlova, Vera; Shaw, Adam; Hand, Jeffrey; #, ||

    2010-01-01

    A method for focusing high intensity ultrasound through a rib cage that aims to minimize heating of the ribs whilst maintaining high intensities at the focus (or foci) is proposed and tested theoretically and experimentally. Two approaches, one based on geometric acoustics and the other accounting for diffraction effects associated with propagation through the rib cage, are investigated theoretically for idealized source conditions. It is shown that for an idealized radiator the diffraction approach provides a 23% gain in peak intensity and results in significantly less power losses on the ribs (1% versus 7.5% of the irradiated power) compared with the geometric one. A 2D 1-MHz phased array with 254 randomly distributed elements, tissue mimicking phantoms, and samples of porcine rib cages are used in experiments; the geometric approach is used to configure how the array is driven. Intensity distributions are measured in the plane of the ribs and in the focal plane using an infra-red camera. Theoretical and experimental results show that it is possible to provide adequate focusing through the ribs without overheating them for a single focus and several foci, including steering at ± 10–15 mm off and ± 20 mm along the array axis. Focus splitting due to the periodic spatial structure of ribs is demonstrated both in simulations and experiments; the parameters of splitting are quantified. The ability to produce thermal lesions with a split focal pattern in ex vivo porcine tissue placed beyond the rib phantom is also demonstrated. The results suggest that the method is potentially useful for clinical applications of HIFU for which the rib cage lies between the transducer(s) and the targeted tissue. PMID:20510186

  10. Highly Selective Dual-Mode Microstrip Bandpass Filters Using Triangular Patch Resonators

    Directory of Open Access Journals (Sweden)

    K.G. Avinash

    2017-03-01

    Full Text Available In this paper, highly selective dual-mode microstrip bandpass filters are proposed using horizontal and vertical slots formed on the surface of a triangular patch. Slots are responsible for splitting and coupling of dual degenerate modes and also facilitate in controlling their resonant frequencies by varying the dimensions of the slots. Horizontal and vertical slots reroute the direction of the flow of current on the surface of the patch, which results in switching of transmission zeros. Two 2-pole and one 4-pole dual-mode filters are designed, simulated and fabricated. Two pole filters have transmission zeros on side of the passband and four pole filter have transmission zeros on both sides of the passband. The designed filters exhibit a fractional bandwidth of less than 7 % and there is a good agreement between simulated and measured results.

  11. Small Externally-fueled Heat Pipe Thermionic Reactor (SEHPTR) for dual mode applications

    Science.gov (United States)

    Malloy, John; Jacox, Michael; Zubrin, Robert

    1992-07-01

    The Small Externally Fueled Heat-Pipe Thermionic Reactor (SEHPTR) is described in the context of applications as a dual-mode nuclear power source for satellites. The SEHPTR is a thermionic power system based on a reactor with modular fuel elements around cylindrical thermionic heat-pipe modules with diodes for heat rejection. The SEHPTR concept is theorized to be suitable for directly heating hydrogen gas in the core to increase propulsion and reduce orbit-transfer times. The advantages of dual-mode operation of the SEHPTR are listed including enhanced mission safety and performance at relatively low costs. The SEHPTR could provide direct thermal thrust and an integrated stage that symbiotically utilizes electric power, direct thrust, and hydrogen arcjets. The system is argued to be more effective than a nuclear power system designed solely for electrical power production.

  12. Design of dual-mode optical fibres for the FTTH applications

    Science.gov (United States)

    Chen, Ming-Yang; Li, Yu-Rong; Zhang, Yin; Zhu, Yuan-Feng; Zhang, Yong-Kang; Zhou, Jun

    2011-01-01

    We present in this article a proposal and design for dual-mode optical fibres for fibre-to-the-home applications. High-order modes in the fibre can be effectively suppressed by the connection of the fibre with standard single-mode optical fibres at the two ends of the fibre. The alignment tolerance at the splicing process is presented. In particular, a low bending loss operation with low splice loss is demonstrated using the proposed technique.

  13. Highly sensitive dual mode electrochemical platform for microRNA detection

    OpenAIRE

    Jolly, Pawan; Batistuti, Marina R.; Miodek, Anna; Zhurauski, Pavel; Mulato, Marcelo; Lindsay, Mark A.; Estrela, Pedro

    2016-01-01

    MicroRNAs (miRNAs) play crucial regulatory roles in various human diseases including cancer, making them promising biomarkers. However, given the low levels of miRNAs present in blood, their use as cancer biomarkers requires the development of simple and effective analytical methods. Herein, we report the development of a highly sensitive dual mode electrochemical platform for the detection of microRNAs. The platform was developed using peptide nucleic acids as probes on gold electrode surfac...

  14. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging.

    Science.gov (United States)

    Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T

    2009-10-01

    State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.

  16. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  17. A 63 element 1.75 dimensional ultrasound phased array for the treatment of benign prostatic hyperplasia

    Directory of Open Access Journals (Sweden)

    Smith Nadine

    2005-06-01

    Full Text Available Abstract Background Prostate cancer and benign prostatic hyperplasia are very common diseases in older American men, thus having a reliable treatment modality for both diseases is of great importance. The currently used treating options, mainly surgical ones, have numerous complications, which include the many side effects that accompany such procedures, besides the invasive nature of such techniques. Focused ultrasound is a relatively new treating modality that is showing promising results in treating prostate cancer and benign prostatic hyperplasia. Thus this technique is gaining more attention in the past decade as a non-invasive method to treat both diseases. Methods In this paper, the design, construction and evaluation of a 1.75 dimensional ultrasound phased array to be used for treating prostate cancer and benign prostatic hyperplasia is presented. With this array, the position of the focus can be controlled by changing the electrical power and phase to the individual elements for electronically focusing and steering in a three dimensional volume. The array was designed with a maximum steering angle of ± 13.5° in the transverse direction and a maximum depth of penetration of 11 cm, which allows the treatment of large prostates. The transducer piezoelectric ceramic, matching layers and cable impedance have been designed for maximum power transfer to tissue. Results To verify the capability of the transducer for focusing and steering, exposimetry was performed and the results correlated well with the calculated field. Ex vivo experiments using bovine tissue were performed with various lesion sizes and indicated the capability of the transducer to ablate tissue using short sonications. Conclusion A 1.75 dimensional array, that overcame the drawbacks associated with one-dimensional arrays, has been designed, built and successfully tested. Design issues, such as cable and ceramic capacitances, were taken into account when designing this

  18. Surgical Workflow Analysis: Ideal Application of Navigated Linear Array Ultrasound in Low-Grade Glioma Surgery.

    Science.gov (United States)

    Lothes, Thomas Ernst; Siekmann, Max; König, Ralph Werner; Wirtz, Christian Rainer; Coburger, Jan

    2016-11-01

    Background  Intraoperative imaging in low-grade glioma (LGG) surgery can facilitate residual tumor control and improve surgical outcome. The aim of the study was to evaluate the ideal application and typical interactions of intraoperative MRI (iMRI), conventional low-frequency intraoperative ultrasound (cioUS), and high-frequency linear array intraoperative ultrasound (lioUS) to optimize surgical workflow. Methods  Prospectively, we included 11 patients with an LGG. Typical procedural workflow in the iMRI suite was recorded with a compatible software. We took notes of duration, frequency of application, the surgeon's evaluation of image quality, and the respective benefit of lioUS (15 MHz), cioUS (7 MHz), and iMRI (1.5 T). With the help of the workflow software, we meticulously analyzed ∼ 55 hours of surgery. Results  During the interventions, lioUS was used more often (76.3%) than cioUS (23.7%) and showed a better mean image quality (1 = best to 6 = worst) of 2.08 versus 3.26 with cioUS. The benefit of the lioUS application was rated with an average of 2.27, whereas the cioUS probe only reached a mean value of 3.83. The most common application of lioUS was resection control (42.6%); cioUS was used mainly for orientation (63.2%). Overall, lioUS was used more often and was rated better for both the purposes just described regarding image quality and benefit. Estimated residual tumor based on lioUS alone was lower than the final residual tumor detected with iMRI (7.5% versus 14.5%). The latter technique was rated as the best imaging modality for resection control in all cases followed by lioUS. Conclusion  We provide proof of principle for workflow assessment in cranial neurosurgery. Although iMRI remains the imaging method of choice, lioUS has shown to be beneficial in a combined setup. Evaluation of lioUS was significantly superior to cioUS in most indications except for subcortical lesions. Georg Thieme Verlag KG Stuttgart · New York.

  19. A dual-mode proximity sensor with integrated capacitive and temperature sensing units

    International Nuclear Information System (INIS)

    Qiu, Shihua; Huang, Ying; He, Xiaoyue; Sun, Zhiguang; Liu, Ping; Liu, Caixia

    2015-01-01

    The proximity sensor is one of the most important devices in the field of robot application. It can accurately provide the proximity information to assistant robots to interact with human beings and the external environment safely. In this paper, we have proposed and demonstrated a dual-mode proximity sensor composed of capacitive and resistive sensing units. We defined the capacitive type proximity sensor perceiving the proximity information as C-mode and the resistive type proximity sensor detecting as R-mode. Graphene nanoplatelets (GNPs) were chosen as the R-mode sensing material because of its high performance. The dual-mode proximity sensor presents the following features: (1) the sensing distance of the dual-mode proximity sensor has been enlarged compared with the single capacitive proximity sensor in the same geometrical pattern; (2) experiments have verified that the proposed sensor can sense the proximity information of different materials; (3) the proximity sensing capability of the sensor has been improved by two modes perceive collaboratively, for a plastic block at a temperature of 60 °C: the R-mode will perceive the proximity information when the distance d between the sensor and object is 6.0–17.0 mm and the C-mode will do that when their interval is 0–2.0 mm; additionally two modes will work together when the distance is 2.0–6.0 mm. These features indicate our transducer is very valuable in skin-like sensing applications. (paper)

  20. A Miniaturized Dual-Mode Bandpass Filter Using Slot Spurline Technique

    Directory of Open Access Journals (Sweden)

    Haiwen Liu

    2013-01-01

    Full Text Available A miniaturized dual-mode bandpass filter (BPF with elliptic function response using slot spurline is designed in this paper. The slot spurline can not only splits the degenerate modes but also determine the type of filter characteristic (Chebyshev or elliptic. To miniaturize the resonator, four sagittate stubs are proposed. For demonstration purpose, a BPF operating at 5.75 GHz for WLAN application was designed, fabricated, and measured. The measured results are in good agreement with the full-wave simulation results.

  1. Dual-mode self-validating resistance/Johnson noise thermometer system

    Science.gov (United States)

    Shepard, Robert L.; Blalock, Theron V.; Roberts, Michael J.

    1993-01-01

    A dual-mode Johnson noise and DC resistance thermometer capable of use in control systems where prompt indications of temperature changes and long term accuracy are needed. A resistance-inductance-capacitance (RLC) tuned circuit produces a continuous voltage signal for Johnson noise temperature measurement. The RLC circuit provides a mean-squared noise voltage that depends only on the capacitance used and the temperature of the sensor. The sensor has four leads for simultaneous coupling to a noise signal processor and to a DC resistance signal processor.

  2. Dual-mode endomicroscopy for detection of epithelial dysplasia in the mouth: a descriptive pilot study

    Science.gov (United States)

    Bodenschatz, Nico; Poh, Catherine F.; Lam, Sylvia; Lane, Pierre; Guillaud, Martial; MacAulay, Calum E.

    2017-08-01

    Dual-mode endomicroscopy is a diagnostic tool for early cancer detection. It combines the high-resolution nuclear tissue contrast of fluorescence endomicroscopy with quantified depth-dependent epithelial backscattering as obtained by diffuse optical microscopy. In an in vivo pilot imaging study of 27 oral lesions from 21 patients, we demonstrate the complementary diagnostic value of both modalities and show correlations between grade of epithelial dysplasia and relative depth-dependent shifts in light backscattering. When combined, the two modalities provide diagnostic sensitivity to both moderate and severe epithelial dysplasia in vivo.

  3. Tunable single and dual mode operation of an external cavity quantum-dot injection laser

    Energy Technology Data Exchange (ETDEWEB)

    Biebersdorf, A [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); Lingk, C [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); De Giorgi, M [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); Feldmann, J [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); Sacher, J [Sacher Lasertechnik GmbH, Hannah Arendt Strasse 3-7, D-35037 Marburg (Germany); Arzberger, M [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Ulbrich, C [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Boehm, G [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Amann, M-C [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Abstreiter, G [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany)

    2003-08-21

    We investigate quantum-dot (QD) lasers in an external cavity using Littrow and Littman configurations. Here, we report on a continuously tunable QD laser with a broad tuning range from 1047 to 1130 nm with high stability and efficient side mode suppression. The full-width at half-maximum of the laser line is 0.85 nm determined mainly by the quality of the external grating. This laser can be operated in a dual-mode modus, where the mode-spacing can be tuned continuously between 1.1 and 34 nm. Simultaneous emission of the two laser modes is shown by sum frequency generation experiments.

  4. First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

    Science.gov (United States)

    Stephens, Douglas N; Truong, Uyen T; Nikoozadeh, Amin; Oralkan, Omer; Seo, Chi Hyung; Cannata, Jonathan; Dentinger, Aaron; Thomenius, Kai; de la Rama, Alan; Nguyen, Tho; Lin, Feng; Khuri-Yakub, Pierre; Mahajan, Aman; Shivkumar, Kalyanam; O'Donnell, Matt; Sahn, David J

    2012-02-01

    The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures.

  5. Ultrasound

    Science.gov (United States)

    ... chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. ... by: Jason Levy, MD, Northside Radiology Associates, Atlanta, GA. Also ...

  6. A dual-mode 6-9 GHz transmitter for OFDM-UWB

    International Nuclear Information System (INIS)

    Chen Yunfeng; Gao Ting; Li Wei; Li Ning; Ren Junyan

    2011-01-01

    This paper presents a fully integrated dual-mode 6 to 9 GHz transmitter for both WiMedia and China MB-OFDM UWB applications. The proposed transmitter consists of a dual-mode I/QLPF, an up-conversion mixer, a two-stage power driver amplifier and a broadband high-speed frequency divider with LO buffers for I/Q LO carrier generation. The measurement results show that the gain ripple of the transmitter is within ±1.5/±2.8 dB from 6 to 8.7/9 GHz. The output IP3 is about +13.2 dBm, the output 1dBCP is around +2.8 dBm, and the LO leakage/sideband rejection ratio is about -35/-38 dBc. The ESD protected chip is fabricated with a TSMC 0.13 μm RFCMOS process with a die size of 1.6 x 1.3 mm 2 and the core circuit consumes only 46 mA under a 1.2 V supply. (semiconductor integrated circuits)

  7. A dual-mode 6-9 GHz transmitter for OFDM-UWB

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yunfeng; Gao Ting; Li Wei; Li Ning; Ren Junyan, E-mail: jyren@fudan.edu.cn, E-mail: w-li@fudan.edu.cn [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2011-05-15

    This paper presents a fully integrated dual-mode 6 to 9 GHz transmitter for both WiMedia and China MB-OFDM UWB applications. The proposed transmitter consists of a dual-mode I/QLPF, an up-conversion mixer, a two-stage power driver amplifier and a broadband high-speed frequency divider with LO buffers for I/Q LO carrier generation. The measurement results show that the gain ripple of the transmitter is within {+-}1.5/{+-}2.8 dB from 6 to 8.7/9 GHz. The output IP3 is about +13.2 dBm, the output 1dBCP is around +2.8 dBm, and the LO leakage/sideband rejection ratio is about -35/-38 dBc. The ESD protected chip is fabricated with a TSMC 0.13 {mu}m RFCMOS process with a die size of 1.6 x 1.3 mm{sup 2} and the core circuit consumes only 46 mA under a 1.2 V supply. (semiconductor integrated circuits)

  8. 60-GHz Millimeter-wave Over Fiber with Directly Modulated Dual-mode Laser Diode

    Science.gov (United States)

    Tsai, Cheng-Ting; Lin, Chi-Hsiang; Lin, Chun-Ting; Chi, Yu-Chieh; Lin, Gong-Ru

    2016-01-01

    A directly modulated dual-mode laser diode (DMLD) with third-order intermodulation distortion (IMD3) suppression is proposed for a 60-GHz millimeter-wave over fiber (MMWoF) architecture, enabling new fiber-wireless communication access to cover 4-km single-mode-fiber (SMF) and 3-m wireless 16-QAM OFDM transmissions. By dual-mode injection-locking, the throughput degradation of the DMLD is mitigated with saturation effect to reduce its threshold, IMD3 power and relative intensity noise to 7.7 mA, −85 dBm and −110.4 dBc/Hz, respectively, providing huge spurious-free dynamic range of 85.8 dB/Hz2/3. This operation suppresses the noise floor of the DMLD carried QPSK-OFDM spectrum by 5 dB. The optical receiving power is optimized to restrict the power fading effect for improving the bit error rate to 1.9 × 10−3 and the receiving power penalty to 1.1 dB. Such DMLD based hybrid architecture for 60-GHz MMW fiber-wireless access can directly cover the current optical and wireless networks for next-generation indoor and short-reach mobile communications. PMID:27297267

  9. Dual-mode operation of 2D material-base hot electron transistors

    KAUST Repository

    Lan, Yann-Wen

    2016-09-01

    Vertical hot electron transistors incorporating atomically-thin 2D materials, such as graphene or MoS2, in the base region have been proposed and demonstrated in the development of electronic and optoelectronic applications. To the best of our knowledge, all previous 2D material-base hot electron transistors only considered applying a positive collector-base potential (V-CB > 0) as is necessary for the typical unipolar hot-electron transistor behavior. Here we demonstrate a novel functionality, specifically a dual-mode operation, in our 2D material-base hot electron transistors (e.g. with either graphene or MoS2 in the base region) with the application of a negative collector-base potential (V-CB < 0). That is, our 2D material-base hot electron transistors can operate in either a hot-electron or a reverse-current dominating mode depending upon the particular polarity of VCB. Furthermore, these devices operate at room temperature and their current gains can be dynamically tuned by varying VCB. We anticipate our multi-functional dual-mode transistors will pave the way towards the realization of novel flexible 2D material-based high-density and low-energy hot-carrier electronic applications.

  10. Carbon Nanodots as Dual-Mode Nanosensors for Selective Detection of Hydrogen Peroxide

    Science.gov (United States)

    Shen, Cheng-Long; Su, Li-Xia; Zang, Jin-Hao; Li, Xin-Jian; Lou, Qing; Shan, Chong-Xin

    2017-07-01

    Hydrogen peroxide (H2O2) is an important product of oxidase-based enzymatic reactions, such as glucose/glucose oxidase (GOD) reaction. Therefore, the probing of generated H2O2 for achieving the detection of various carbohydrates and their oxidases is very significative. Herein, we report one kind of dual-emission carbon nanodots (CDs) that can serve as novel dual-mode nanosensors with both fluorometric and colorimetric output for the selective detection of H2O2. The dual-model nanosensors are established only by the undecorated dual-emission CDs, where significant fluorometric and colorimetric changes are observed with the addition of different concentrations of H2O2 in the CD solution, which benefit to the achievement of the naked-eye detection for H2O2. The mechanism of the nanosensors can be attributed to the fact that the external chemical stimuli like hydroxyl radicals from H2O2 bring about the change of surface properties and the aggregation of CDs, which dominate the emission and absorption of CDs. The constructed dual-mode nanosensors exhibit good biocompatibility and high selectivity toward H2O2 with a linear detection range spanning from 0.05 to 0.5 M and allow the detection of H2O2 as low as 14 mM.

  11. Highly sensitive dual mode electrochemical platform for microRNA detection

    Science.gov (United States)

    Jolly, Pawan; Batistuti, Marina R.; Miodek, Anna; Zhurauski, Pavel; Mulato, Marcelo; Lindsay, Mark A.; Estrela, Pedro

    2016-11-01

    MicroRNAs (miRNAs) play crucial regulatory roles in various human diseases including cancer, making them promising biomarkers. However, given the low levels of miRNAs present in blood, their use as cancer biomarkers requires the development of simple and effective analytical methods. Herein, we report the development of a highly sensitive dual mode electrochemical platform for the detection of microRNAs. The platform was developed using peptide nucleic acids as probes on gold electrode surfaces to capture target miRNAs. A simple amplification strategy using gold nanoparticles has been employed exploiting the inherent charges of the nucleic acids. Electrochemical impedance spectroscopy was used to monitor the changes in capacitance upon any binding event, without the need for any redox markers. By using thiolated ferrocene, a complementary detection mode on the same sensor was developed where the increasing peaks of ferrocene were recorded using square wave voltammetry with increasing miRNA concentration. This dual-mode approach allows detection of miRNA with a limit of detection of 0.37 fM and a wide dynamic range from 1 fM to 100 nM along with clear distinction from mismatched target miRNA sequences. The electrochemical platform developed can be easily expanded to other miRNA/DNA detection along with the development of microarray platforms.

  12. Bioinspired Flexible and Highly Responsive Dual-Mode Strain/Magnetism Composite Sensor.

    Science.gov (United States)

    Huang, Pei; Li, Yuan-Qing; Yu, Xiao-Guang; Zhu, Wei-Bin; Nie, Shu-Yan; Zhang, Hao; Liu, Jin-Rui; Hu, Ning; Fu, Shao-Yun

    2018-04-04

    The mimicry of human skin to detect both oncoming and physical-contacting object is of great importance in the fields of manufacturing, artificial robots and vehicles, etc. Herein, a novel bioinspired flexible and highly responsive dual-mode strain/magnetism composite sensor, which works via both contact and contactless modes, is first fabricated by incorporating Fe 3 O 4 /silicone system into a carbon fiber aerogel (CFA). The distance dependence of magnetic field endorses the CFA/Fe 3 O 4 /silicone composite possible for spatial sensing due to the introduction of Fe 3 O 4 magnetic nanoparticles. As a result, the as-prepared flexible sensor exhibits precise and real-time response not only to direct-contact compression as usual but also to contactless magnetic field in a wide frequency range from 0.1 to 10 Hz, achieving the maximum variance of 68% and 86% in relative electrical resistance, respectively. The contact and contactless sensing modes of the strain/magnetism sensor are clearly demonstrated by recording the speeds of bicycle riding and walking, respectively. Interestingly, this dual-mode composite sensor exhibits the capacity of identifying the contact and contactless state, which is the first report for flexible sensors. The current protocol is eco-friendly, facile, and thought-provoking for the fabrication of multifunctional sensors.

  13. Targeted hyperthermia in prostate with an MR-guided endorectal ultrasound phased array: patient specific modeling and preliminary experiments

    Science.gov (United States)

    Salgaonkar, Vasant A.; Prakash, Punit; Plata, Juan; Holbrook, Andrew; Rieke, Viola; Kurhanewicz, John; Hsu, I.-C.; Diederich, Chris J.

    2013-02-01

    Feasibility of hyperthermia delivery to the prostate with a commercially available MR-guided endorectal ultrasound (ERUS) phased array ablation system (ExAblate 2100, Insightec, LTD) was assessed through computer simulations and ex vivo experiments. The simulations included a 3D FEM-based biothermal model, and acoustic field calculations for the ExAblate phased array (2.3 MHz, 2.3x4.0 cm2) using the rectangular radiator method. Array beamforming strategies were investigated to deliver 30-min hyperthermia (W/cm2, and in 3-10 cm3 for curvilinear (cylindrical) or multifocus beam patterns at 1.5-3.3 W/cm2, potentially useful for treating focal disease in a single posterior quadrant. Preliminary experiments included beamformed sonications in tissue mimicking phantom material under MRI-based temperature monitoring at 3T (GRE TE=7.0 ms, TR=15 ms, BW=10.5 kHz, FOV=15 cm, matrix 128x128, FA=40°). MR-temperature rises of 2-6 °C were induced in a phantom with the ExAblate array, consistent with calculated values and lower power settings (~0.86 W/cm2, 3 min.). Conformable hyperthermia may be delivered by tailoring power deposition along the array length and angular expanse. MRgERUS HIFU systems can be controlled for continuous hyperthermia in prostate to augment radiotherapy and drug delivery. [FUS Foundation, NIH R01 122276, 111981].

  14. Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronics.

    Science.gov (United States)

    Nikoozadeh, Amin; Wygant, Ira O; Lin, Der-Song; Oralkan, Omer; Ergun, A Sanli; Stephens, Douglas N; Thomenius, Kai E; Dentinger, Aaron M; Wildes, Douglas; Akopyan, Gina; Shivkumar, Kalyanam; Mahajan, Aman; Sahn, David J; Khuri-Yakub, Butrus T

    2008-12-01

    Minimally invasive catheter-based electrophysiological (EP) interventions are becoming a standard procedure in diagnosis and treatment of cardiac arrhythmias. As a result of technological advances that enable small feature sizes and a high level of integration, nonfluoroscopic intracardiac echocardiography (ICE) imaging catheters are attracting increasing attention. ICE catheters improve EP procedural guidance while reducing the undesirable use of fluoroscopy, which is currently the common catheter guidance method. Phased-array ICE catheters have been in use for several years now, although only for side-looking imaging. We are developing a forward-looking ICE catheter for improved visualization. In this effort, we fabricate a 24-element, fine-pitch 1-D array of capacitive micromachined ultrasonic transducers (CMUT), with a total footprint of 1.73 mm x 1.27 mm. We also design a custom integrated circuit (IC) composed of 24 identical blocks of transmit/ receive circuitry, measuring 2.1 mm x 2.1 mm. The transmit circuitry is capable of delivering 25-V unipolar pulses, and the receive circuitry includes a transimpedance preamplifier followed by an output buffer. The CMUT array and the custom IC are designed to be mounted at the tip of a 10-Fr catheter for high-frame-rate forward-looking intracardiac imaging. Through-wafer vias incorporated in the CMUT array provide access to individual array elements from the back side of the array. We successfully flip-chip bond a CMUT array to the custom IC with 100% yield. We coat the device with a layer of polydimethylsiloxane (PDMS) to electrically isolate the device for imaging in water and tissue. The pulse-echo in water from a total plane reflector has a center frequency of 9.2 MHz with a 96% fractional bandwidth. Finally, we demonstrate the imaging capability of the integrated device on commercial phantoms and on a beating ex vivo rabbit heart (Langendorff model) using a commercial ultrasound imaging system.

  15. A Flexible Ultrasound Transducer Array with Micro-Machined Bulk PZT

    Directory of Open Access Journals (Sweden)

    Zhe Wang

    2015-01-01

    Full Text Available This paper proposes a novel flexible piezoelectric micro-machined ultrasound transducer, which is based on PZT and a polyimide substrate. The transducer is made on the polyimide substrate and packaged with medical polydimethylsiloxane. Instead of etching the PZT ceramic, this paper proposes a method of putting diced PZT blocks into holes on the polyimide which are pre-etched. The device works in d31 mode and the electromechanical coupling factor is 22.25%. Its flexibility, good conformal contacting with skin surfaces and proper resonant frequency make the device suitable for heart imaging. The flexible packaging ultrasound transducer also has a good waterproof performance after hundreds of ultrasonic electric tests in water. It is a promising ultrasound transducer and will be an effective supplementary ultrasound imaging method in the practical applications.

  16. Miniaturized ultrasound imaging probes enabled by CMUT arrays with integrated frontend electronic circuits.

    Science.gov (United States)

    Khuri-Yakub, B T; Oralkan, Omer; Nikoozadeh, Amin; Wygant, Ira O; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O'Donnell, Matthew; Truong, Uyen; Sahn, David J

    2010-01-01

    Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics.

  17. An overmoded relativistic backward wave oscillator with efficient dual-mode operation

    International Nuclear Information System (INIS)

    Xiao, Renzhen; Li, Jiawei; Bai, Xianchen; Song, Zhimin; Teng, Yan; Ye, Hu; Li, Xiaoze; Sun, Jun; Chen, Changhua; Zhang, Xiaowei

    2014-01-01

    A dual-mode operation mechanism in an overmoded relativistic backward wave oscillator is presented. The electron beam interacts with the −1st space harmonic of TM 01 mode synchronously in the slow wave structure. Then the backward propagating TM 01 mode is converted to the forward propagating TM 02 mode. As the phase velocity of the volume harmonic of TM 02 mode is about twice that of the surface harmonic of TM 01 mode, the TM 02 mode also plays an important role in the high-power microwave generation. Particle-in-cell simulation shows that an efficiency of 48% and a significant improvement of the power capacity have been obtained

  18. Dual-Mode Combustion of Hydrogen in a Mach 5, Continuous-Flow Facility

    Science.gov (United States)

    Goyne, C. P.; McDaniel, J. C.; Quagliaroli, T. M.; Krauss, R. H.; Day, S. W.; Reubush, D. E. (Technical Monitor); McClinton, C. R. (Technical Monitor); Reubush, D. E.

    2001-01-01

    Results of an experimental and numerical study of a dual-mode scramjet combustor are reported. The experiment consisted of a direct-connect test of a Mach 2 hydrogen-air combustor with a single unswept-ramp fuel injector. The flow stagnation enthalpy simulated a flight Mach number of 5. Measurements were obtained using conventional wall instrumentation and a particle-imaging laser diagnostic technique. The particle imaging was enabled through the development of a new apparatus for seeding fine silicon dioxide particles into the combustor fuel stream. Numerical simulations of the combustor were performed using the GASP code. The modeling, and much of the experimental work, focused on the supersonic combustion mode. Reasonable agreement was observed between experimental and numerical wall pressure distributions. However, the numerical model was unable to predict accurately the effects of combustion on the fuel plume size, penetration, shape, and axial growth.

  19. Dual-mode gradient HPLC procedure for the simultaneous determination of chloroquine and proguanil.

    Science.gov (United States)

    Paci, A; Caire-Maurisier, A-M; Rieutord, A; Brion, F; Clair, P

    2002-01-01

    In order to assay the antipaludic capsule of the Service de Santé des Armées (SSA), that contains two antimalarial drugs, i.e. chloroquine sulfate (CQS, cp1) and proguanil hydrochloride (PGH, cp5), a HPLC procedure was developed. A reversed-phase ion-pair high-performance liquid chromatography (HPLC) method with an ultraviolet detection at 254 nm was set up and validated. Elution system includes programming of both organic concentration and flow-rate known as 'dual-mode gradient'. This method allows the simultaneous determination of both active compounds and separation of four process related substances. The method is simple, rapid, selective and accurate, and the precision is good with an inter- and intra-assay of <2%. The sensitivity is particularly suitable for pharmaceutical quality control.

  20. Observation of dual-mode, Kelvin-Helmholtz instability vortex merger in a compressible flow

    Science.gov (United States)

    Wan, W. C.; Malamud, G.; Shimony, A.; Di Stefano, C. A.; Trantham, M. R.; Klein, S. R.; Shvarts, D.; Drake, R. P.; Kuranz, C. C.

    2017-05-01

    We report the first observations of Kelvin-Helmholtz vortices evolving from well-characterized, dual-mode initial conditions in a steady, supersonic flow. The results provide the first measurements of the instability's vortex merger rate and supplement data on the inhibition of the instability's growth rate in a compressible flow. These experimental data were obtained by sustaining a shockwave over a foam-plastic interface with a precision-machined seed perturbation. This technique produced a strong shear layer between two plasmas at high-energy-density conditions. The system was diagnosed using x-ray radiography and was well-reproduced using hydrodynamic simulations. Experimental measurements imply that we observed the anticipated vortex merger rate and growth inhibition for supersonic shear flow.

  1. 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

    Science.gov (United States)

    Yeh, David T; Oralkan, Omer; Wygant, Ira O; O'Donnell, Matthew; Khuri-Yakub, Butrus T

    2006-06-01

    Forward-viewing ring arrays can enable new applications in intravascular and intracardiac ultrasound. This work presents compelling, full-synthetic, phased-array volumetric images from a forward-viewing capacitive micromachined ultrasonic transducer (CMUT) ring array wire bonded to a custom integrated circuit front end. The CMUT ring array has a diameter of 2 mm and 64 elements each 100 microm x 100 microm in size. In conventional mode, echo signals received from a plane reflector at 5 mm had 70% fractional bandwidth around a center frequency of 8.3 MHz. In collapse mode, 69% fractional bandwidth is measured around 19 MHz. Measured signal-to-noise ratio (SNR) of the echo averaged 16 times was 29 dB for conventional operation and 35 dB for collapse mode. B-scans were generated of a target consisting of steel wires 0.3 mm in diameter to determine resolution performance. The 6 dB axial and lateral resolutions for the B-scan of the wire target are 189 microm and 0.112 radians for 8 MHz, and 78 microm and 0.051 radians for 19 MHz. A reduced firing set suitable for real-time, intravascular applications was generated and shown to produce acceptable images. Rendered three-dimensional (3-D) images of a Palmaz-Schatz stent also are shown, demonstrating that the imaging quality is sufficient for practical applications.

  2. An integrated ultrasound-guided high intensity focused ultrasound system for in-vivo experiment

    Science.gov (United States)

    Liu, Dalong; Ebbini, Emad S.

    2017-03-01

    We present the system architecture of an integrated Ultrasound-guided High Intensity Focused Ultrasound (USgHIFU) system for image-guided surgery and temperature tracking in vivo. The system is capable of operating with multiple frontends. Current implementation has a SonixRP for imaging and a custom designed dual mode ultrasound array (DMUA) system (32Tx/32Rx) for imaging/therapy. The highlights of the system include a fully-programmable, multiple data stream capable data processing engine, and an arbitrarily programmable high power array driver that is able to synthesize complex beam patterns in space and time. The data processing engine features a pipeline-style design that can be programmed on-the-fly by re-arranging the pre-verified GPU-accelerated high performance pipeline blocks, which cover an extensive range from basic functions such as filtering to specialized processing like speckle tracking. Furthermore, the pipeline design also has the option of bringing in MATLAB (Mathworks, Natick, MA, US) as part of the processing chain, thus vastly increase the capability of the system. By properly balancing the processing load between GPU-enabled routine and MATLAB script. This allows one to achieve a high degree of flexibility while meeting real-time constraints. Results are presented from in vivo rat experiment. Where low dose of therapeutic ultrasound was delivered into the hind limb of the Copenhagen rats using DMUA and temperature was tracked using a linear probe (HST, Ultrasonix). The data is processed in realtime with MATLAB in the loop to perform temperature regularization. Results show that we can reliably track the low temperature heating in the presence of motion artifacts (respiration and pulsation).

  3. Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: whole-body tomographic system for small animals.

    Science.gov (United States)

    Gateau, Jerome; Caballero, Miguel Angel Araque; Dima, Alexander; Ntziachristos, Vasilis

    2013-01-01

    Optoacoustic imaging relies on the detection of ultrasonic waves induced by laser pulse excitations to map optical absorption in biological tissue. A tomographic geometry employing a conventional ultrasound linear detector array for volumetric optoacoustic imaging is reported. The geometry is based on a translate-rotate scanning motion of the detector array, and capitalizes on the geometrical characteristics of the transducer assembly to provide a large solid angular detection aperture. A system for three-dimensional whole-body optoacoustic tomography of small animals is implemented. The detection geometry was tested using a 128-element linear array (5.0∕7.0 MHz, Acuson L7, Siemens), moved by steps with a rotation∕translation stage assembly. Translation and rotation range of 13.5 mm and 180°, respectively, were implemented. Optoacoustic emissions were induced in tissue-mimicking phantoms and ex vivo mice using a pulsed laser operating in the near-IR spectral range at 760 nm. Volumetric images were formed using a filtered backprojection algorithm. The resolution of the optoacoustic tomography system was measured to be better than 130 μm in-plane and 330 μm in elevation (full width half maximum), and to be homogenous along a 15 mm diameter cross section due to the translate-rotate scanning geometry. Whole-body volumetric optoacoustic images of mice were performed ex vivo, and imaged organs and blood vessels through the intact abdominal and head regions were correlated to the mouse anatomy. Overall, the feasibility of three-dimensional and high-resolution whole-body optoacoustic imaging of small animal using a conventional linear array was demonstrated. Furthermore, the scanning geometry may be used for other linear arrays and is therefore expected to be of great interest for optoacoustic tomography at macroscopic and mesoscopic scale. Specifically, conventional detector arrays with higher central frequencies may be investigated.

  4. Reconfigurable/tunable dual band/dual mode ferrite composite right/left-handed CPW coupled-line coupler

    Science.gov (United States)

    Abdalla, M. A.; Hu, Z.

    2017-09-01

    This paper presents the design, modeling and experimental verification of a novel reconfigurable/tunable dual band/dual mode ferrite composite right/left handed CPW coupled-line coupler. The composite right/left handed configuration has been realized by loading coupled CPW transmission lines with series inter-digital capacitors and shunt segment inductors. The coupler performance has been verified using the equivalent circuit model, electromagnetic full wave simulations and experimental measurements. The coupler operates on dual mode in that it has dual bands of operation with two different propagation mechanisms. The first band has only a reciprocal backward coupling whereas the second band has only nonreciprocal through propagation. The non-reciprocity isolation in the second band is better than average of 15 dB. Compared to conventional single band single mode coupled line coupler of length = 0.25 λg, the proposed novel dual band dual mode coupler length is almost the same (0.265 λg) at 4.5 GHz. Furthermore, the dual mode/dual band coupler can have tunable functionality.

  5. Robust equivalent consumption-based controllers for a dual-mode diesel parallel HEV

    International Nuclear Information System (INIS)

    Finesso, Roberto; Spessa, Ezio; Venditti, Mattia

    2016-01-01

    Highlights: • Non-plug-in dual-mode parallel hybrid architecture. • Cross-validation machine-learning for robust equivalent consumption-based controllers. • Optimal control strategy based on fuel consumption, NOx and battery aging. • Impact of different equivalent consumption definitions on HEV performance. • Correlation between vehicle braking energy and SOC variation in the traction stages. - Abstract: New equivalent consumption minimization strategy (ECMS) tools have been developed and applied to identify the optimal control strategy of a dual-mode parallel hybrid electric vehicle equipped with a compression-ignition engine. In this architecture, the electric machine is coupled to the engine through either a single-speed gearbox (torque-coupling) or a planetary gear set (speed-coupling). One of the main novelties of the present study concerns the definition of the instantaneous equivalent consumption (EC) function, which takes into account not only fuel consumption (FC) and the energy flow through the electric components, but also NO x emissions, battery aging, and the battery SOC. The EC function has been trained using a cross-validation machine-learning technique, based on a genetic algorithm, where the training data set has been selected in order to maximize performances over a testing data set. The adoption of this technique, in conjunction with the new definition of EC, have led to the identification of very robust controllers, which provide an accurate control for different driving scenarios, even when the EC function is not specifically trained on the same missions over which it is tested. To this aim, a data set of fifty driving cycles and six user-defined missions, which cover a total distance of 70–100 km, has been considered as a training driving set. The ECMS controllers can be implemented in a vehicle control unit, and their performance has resulted to be close to that of a dynamic programming tool, which has here been used as benchmark

  6. Design of patient-specific focused ultrasound arrays for non-invasive brain therapy with increased trans-skull transmission and steering range

    Science.gov (United States)

    Hughes, Alec; Hynynen, Kullervo

    2017-09-01

    The use of a phased array of ultrasound transducer elements to sonicate through the skull has opened the way for new treatments and the delivery of therapeutics beyond the blood-brain barrier. The limited steering range of current clinical devices, particularly at higher frequencies, limits the regions of the brain that are considered treatable by ultrasound. A new array design is introduced that allows for high levels of beam steering and increased transmission throughout the brain. These improvements are achieved using concave transducers normal to the outer-skull surface in a patient-specific configuration to target within the skull, so that the far-field of each beam is within the brain. It is shown that by using pulsed ultrasound waves timed to arrive in-phase at the desired target, sufficient levels of acoustic energy are delivered for blood-brain barrier opening throughout the brain.

  7. The role of acoustic nonlinearity in tissue heating behind the rib cage using high intensity focused ultrasound phased array

    Science.gov (United States)

    Yuldashev, Petr V.; Shmeleva, Svetlana M.; Ilyin, Sergey A.; Sapozhnikov, Oleg A.; Gavrilov, Leonid R.; Khokhlova, Vera A.

    2013-01-01

    The goal of this study was to investigate theoretically the effects of nonlinear propagation in a high intensity focused ultrasound (HIFU) field produced by a therapeutic phased array and the resultant heating of tissue behind a rib cage. Three configurations of focusing were simulated: in water, in water with ribs in the beam path, and in water with ribs backed by a layer of soft tissue. The Westervelt equation was used to model the nonlinear HIFU field and a 1 MHz phased array consisting of 254 circular elements was used as a boundary condition to the model. The temperature rise in tissue was modelled using the bioheat equation, and thermally necrosed volumes were calculated using the thermal dose formulation. The shapes of lesions predicted by the modelling were compared with those previously obtained in in vitro experiments at low power sonications. Intensity levels at the face of the array elements that corresponded to formation of high amplitude shock fronts in the focal region were determined as 10 W·cm−2 in the free field in water and 40 W·cm−2 in the presence of ribs. It was shown that exposures with shocks provided a substantial increase in tissue heating, and its better spatial localization in the main focal region only. The relative effects of overheating ribs and splitting of the focus due to the periodic structure of the ribs were therefore reduced. These results suggest that utilizing nonlinear propagation and shock formation effects can be beneficial for inducing confined HIFU lesions when irradiating through obstructions such as ribs. Design of compact therapeutic arrays to provide maximum power outputs with lower intensity levels at the elements is necessary to achieve shock wave regimes for clinically relevant sonication depths in tissue. PMID:23528338

  8. Chemiresistive and Gravimetric Dual-Mode Gas Sensor toward Target Recognition and Differentiation.

    Science.gov (United States)

    Chen, Yan; Zhang, Hao; Feng, Zhihong; Zhang, Hongxiang; Zhang, Rui; Yu, Yuanyuan; Tao, Jin; Zhao, Hongyuan; Guo, Wenlan; Pang, Wei; Duan, Xuexin; Liu, Jing; Zhang, Daihua

    2016-08-24

    We demonstrate a dual-mode gas sensor for simultaneous and independent acquisition of electrical and mechanical signals from the same gas adsorption event. The device integrates a graphene field-effect transistor (FET) with a piezoelectric resonator in a seamless manner by leveraging multiple structural and functional synergies. Dual signals resulting from independent physical processes, i.e., mass attachment and charge transfer can reflect intrinsic properties of gas molecules and potentially enable target recognition and quantification at the same time. Fabrication of the device is based on standard Integrated Circuit (IC) foundry processes and fully compatible with system-on-a-chip (SoC) integration to achieve extremely small form factors. In addition, the ability of simultaneous measurements of mass adsorption and charge transfer guides us to a more precise understanding of the interactions between graphene and various gas molecules. Besides its practical functions, the device serves as an effective tool to quantitatively investigate the physical processes and sensing mechanisms for a large library of sensing materials and target analytes.

  9. Dual-Pump CARS Measurements in the University of Virginia's Dual-Mode Scramjet: Configuration "C"

    Science.gov (United States)

    Cutler, Andrew D.; Magnotti, Gaetano; Cantu, Luca; Gallo, Emanuela; Danehy, Paul M.; Rockwell, Robert; Goyne, Christopher; McDaniel, James

    2013-01-01

    Measurements have been conducted at the University of Virginia Supersonic Combustion Facility in configuration C of the dual-mode scramjet. This is a continuation of previously published works on configuration A. The scramjet is hydrogen fueled and operated at two equivalence ratios, one representative of the scram mode and the other of the ram mode. Dual-pump CARS was used to acquire the mole fractions of the major species as well as the rotational and vibrational temperatures of N2. Developments in methods and uncertainties in fitting CARS spectra for vibrational temperature are discussed. Mean quantities and the standard deviation of the turbulent fluctuations at multiple planes in the flow path are presented. In the scram case the combustion of fuel is completed before the end of the measurement domain, while for the ram case the measurement domain extends into the region where the flow is accelerating and combustion is almost completed. Higher vibrational than rotational temperature is observed in those parts of the hot combustion plume where there is substantial H2 (and hence chemical reaction) present.

  10. The two faces of Janus, or the dual mode of public attitudes towards snakes.

    Science.gov (United States)

    Liordos, Vasilios; Kontsiotis, Vasileios J; Kokoris, Spyridon; Pimenidou, Michaela

    2018-04-15

    Snakes are controversial animals, therefore a better understanding of public attitudes is critical for their effective protection and future survival. The attitudes towards snakes of 951 adults in Greece were investigated in personal interviews. Factor analysis revealed a dual mode of attitudes: respondents were highly intolerant of snakes, while they supported their conservation at the same time. Respondents had high knowledge about the behavior of snakes, medium knowledge of their biology and were strongly affected by folklore. Structural models revealed that tolerance was a positive mediator of conservation. Knowledge about snake behavior and biology was positively correlated with attitudes towards snakes. Moralistic and naturalistic attitudes were positively, and dominionistic attitudes negatively, correlated with snake tolerance and conservation attitudes. Younger, more educated people were more snake-tolerant than older, less educated people. Females were less snake-tolerant and more conservation-oriented than males. These findings increased the understanding of human attitudes towards snakes and helped identify factors critical for their conservation. As such they could be used to design environmental education programs incorporating both information-based and experiential activities that will improve attitudes, behaviors and, eventually, the chances for the survival of these uncharismatic animals. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The Development of CyberLearning in Dual-Mode: Higher Education Institutions in Taiwan

    Directory of Open Access Journals (Sweden)

    Yau-Jane Chen

    2002-01-01

    Full Text Available Open and distance education in Taiwan has evolved into the third phase – cyberlearning – conceptualized as teaching and learning interactions mediated entirely through the application of state-of-the-art information and communications technologies (ICT, such as the Internet and World Wide Web. Socio-economic influences, the development of new technologies and a marked shift in learning paradigms have increased the utilization of ICT at all levels of the Taiwanese education system. Since the advent and provision of cyberlearning programs, well over half (56 percent of the conventional universities and colleges have been upgraded to dual-mode higher educational institutions. They offer real-time multicast instructional systems using videoconferencing and cable TV technology, virtual classroom systems via network-based instructional management systems, and curriculum-on-demand systems utilizing video-on-demand technology. Critical success factors in the development of these cyber universities and the opportunities, challenges and implications inherent in these are analyzed. ICT and the provision of cyberlearning have gradually been changing the structure and vision of higher education institutions as well as the entire learning environment and educational systems. Because the Ministry of Education (MOE has initiated a policy on credit-based degrees for cyberlearning courses/ programs, the development of open and distance education is anticipated to hasten the transformation of Taiwan’s education system towards one which will create an ideal learning society in the 21st century.

  12. A dual mode charge pump with adaptive output used in a class G audio power amplifier

    Science.gov (United States)

    Yong, Feng; Zhenfei, Peng; Shanshan, Yang; Zhiliang, Hong; Yang, Liu

    2011-04-01

    A dual mode charge pump to produce an adaptive power supply for a class G audio power amplifier is presented. According to the amplitude of the input signals, the charge pump has two level output voltage rails available to save power. It operates both in current mode at high output load and in pulse frequency modulation (PFM) at light load to reduce the power dissipation. Also, dynamic adjustment of the power stage transistor size based on load current at the PFM mode is introduced to reduce the output voltage ripple and prevent the switching frequency from audio range. The prototype is implemented in 0.18 μm 3.3 V CMOS technology. Experimental results show that the maximum power efficiency of the charge pump is 79.5% @ 0.5x mode and 83.6% @ 1x mode. The output voltage ripple is less than 15 mV while providing 120 mA of the load current at PFM control and less than 18 mV while providing 300 mA of the load current at current mode control. An analytical model for ripple voltage and efficiency calculation of the proposed PFM control demonstrates reasonable agreement with measured results.

  13. A dual-mode complex filter for GNSS receivers with frequency tuning

    Energy Technology Data Exchange (ETDEWEB)

    Gan Yebing; Yuan Guoshun [Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029 (China); Ma Chengyan, E-mail: ganyebing@casic.ac.c [Hangzhou Zhongke Microelectronics Co, Ltd, Hangzhou 310053 (China)

    2009-10-15

    A fifth/seventh order dual-mode OTA-C complex filter for global navigation satellite system receivers is implemented in a 0.18 {mu}m CMOS process. This filter can be configured as the narrow mode of a 4.4 MHz bandwidth center at 4.1 MHz or the wide mode of a 22 MHz bandwidth center at 15.42 MHz. A fully differential OTA with source degeneration is used to provide sufficient linearity. Furthermore, a ring CCO based frequency tuning scheme is proposed to reduce frequency variation. The measured results show that in narrow-band mode the image rejection ratio (IMRR) is 35 dB, the filter dissipates 0.8 mA from the 1.8 V power supply, and the out-of-band rejection is 50 dB at 6 MHz offset. In wide-band mode, IMRR is 28 dB and the filter dissipates 3.2 mA. The frequency tuning error is less than {+-}2%.

  14. Polylactic acid nano- and microchamber arrays for encapsulation of small hydrophilic molecules featuring drug release via high intensity focused ultrasound.

    Science.gov (United States)

    Gai, Meiyu; Frueh, Johannes; Tao, Tianyi; Petrov, Arseniy V; Petrov, Vladimir V; Shesterikov, Evgeniy V; Tverdokhlebov, Sergei I; Sukhorukov, Gleb B

    2017-06-01

    Long term encapsulation combined with spatiotemporal release for a precisely defined quantity of small hydrophilic molecules on demand remains a challenge in various fields ranging from medical drug delivery, controlled release of catalysts to industrial anti-corrosion systems. Free-standing individually sealed polylactic acid (PLA) nano- and microchamber arrays were produced by one-step dip-coating a PDMS stamp into PLA solution for 5 s followed by drying under ambient conditions. The wall thickness of these hydrophobic nano-microchambers is tunable from 150 nm to 7 μm by varying the PLA solution concentration. Furthermore, small hydrophilic molecules were successfully in situ precipitated within individual microchambers in the course of solvent evaporation after sonicating the PLA@PDMS stamp to remove air-bubbles and to load the active substance containing solvent. The cargo capacity of single chambers was determined to be in the range of several picograms, while it amounts to several micrograms per cm 2 . Two different methods for sealing chambers were compared: microcontact printing versus dip-coating whereby microcontact printing onto a flat PLA sheet allows for entrapment of micro-air-bubbles enabling microchambers with both ultrasound responsiveness and reduced permeability. Cargo release triggered by external high intensity focused ultrasound (HIFU) stimuli is demonstrated by experiment and compared with numerical simulations.

  15. Dual-Mode SERS-Fluorescence Immunoassay Using Graphene Quantum Dot Labeling on One-Dimensional Aligned Magnetoplasmonic Nanoparticles.

    Science.gov (United States)

    Zou, Fengming; Zhou, Hongjian; Tan, Tran Van; Kim, Jeonghyo; Koh, Kwangnak; Lee, Jaebeom

    2015-06-10

    A novel dual-mode immunoassay based on surface-enhanced Raman scattering (SERS) and fluorescence was designed using graphene quantum dot (GQD) labels to detect a tuberculosis (TB) antigen, CFP-10, via a newly developed sensing platform of linearly aligned magnetoplasmonic (MagPlas) nanoparticles (NPs). The GQDs were excellent bilabeling materials for simultaneous Raman scattering and photoluminescence (PL). The one-dimensional (1D) alignment of MagPlas NPs simplified the immunoassay process and enabled fast, enhanced signal transduction. With a sandwich-type immunoassay using dual-mode nanoprobes, both SERS signals and fluorescence images were recognized in a highly sensitive and selective manner with a detection limit of 0.0511 pg mL(-1).

  16. Dual mode antimony electrode for simultaneous measurements of PO2 and pH.

    Science.gov (United States)

    Sjöberg, F; Nilsson, G

    2000-01-01

    In biomedical research and clinical medicine there is a demand for potent sensors to measure the components that make up blood gas analyses. Today, as when the electrochemical PO2, PCO2 and pH electrodes were first introduced, these measurements are usually made with the same type of sensor technology. The aims of the present study were, firstly, to find out whether the platinum cathode in the Clark electrode can be replaced by antimony for oxygen measurements (amperometry (A)); secondly, whether, during oxygen measurements, the inherent corrosion potential of the antimony metal can be used for measurement of pH in the same measurement area (potentiometry (P)). An electrode of purified, crystallographically orientated monocrystalline antimony (COMA) connected to a reference electrode (silver-silver chloride) was used for the P measurements. Measurements of A (at -900 mV) and P were made in an aqueous environment regulated for oxygen, pH, and temperature. Reproducible oxygen sensitivities of 0.925 nA/% oxygen (2% CV (coefficient of variation)) (A), 10.7 mV/% (P), and 0.7 mV/% (P) were found in the oxygen range: 0-21%, <5%, and above 5%, respectively. The pH sensitivity was 57 mV/pH unit (P). Oxygen and pH measurements were less accurate at oxygen concentrations close to 0%. Both the oxygen and pH part of the composite electrode signal can be identified by this dual mode technique (A and P). The sensor seems to be promising as it provides measurements of two separate variables (oxygen and pH) and also has the desirable characteristics of a solid state sensor.

  17. Composite nanoparticle of Au and quantum dots for X-ray computed tomography and fluorescence dual-mode imaging in vivo

    International Nuclear Information System (INIS)

    Song, Ji-Tao; Yang, Xiao-Quan; Zhang, Xiao-Shuai; Yan, Dong-Mei; Yao, Ming-Hao; Qin, Meng-Yao; Zhao, Yuan-Di

    2015-01-01

    In this study, composite nanoparticles comprising Au nanoparticle and quantum dots were built and used for contrast-enhanced computed tomography imaging (CT) and fluorescence dual-mode imaging in vivo. The nanoparticle exhibited good monodispersity and good biocompatibility, and had excellent CT contrast-enhancement effect and fluorescence imaging capability. They were appropriate for being used as dual-mode imaging probe in vivo

  18. Detectability comparison of modes in dual-mode digital breast tomosynthesis.

    Science.gov (United States)

    Endo, Tokiko; Morita, Takako; Oiwa, Mikinao; Suda, Namiko; Sato, Yasuyuki; Ichihara, Shu; Shiraiwa, Misaki; Yoshikawa, Kazuaki; Horiba, Takao; Ogawa, Hirotoshi; Hayashi, Yukie; Sendai, Tomonari; Arai, Takahisa

    2017-05-01

    The objectives of this study were: (1) to evaluate the detectability of full-field digital mammography (FFDM) plus dual-mode digital breast tomosynthesis (DBT) and compare it with that of FFDM alone and (2) to compare the detectability of high-resolution-mode (HR mode used with 40°-angle imaging, 100-µm pixel size, and higher dose) DBT with that of standard-mode (ST mode used with 15°-angle imaging, 150-µm pixel size, and lower dose) DBT for diagnostic evaluation. The local Institutional Review Board approved this retrospective study of two different sets of cases. All participants gave written informed consent. FFDM and DBT images of 471 women who were recalled were acquired between August 2013 and October 2014. HR mode and ST mode were applied to 155 breasts and 157 breasts, respectively. The cases of both modes were selected randomly. Eight radiologists interpreted the images. The detectability for recall cases and for follow cases, and area under the receiver operating characteristic curve (AUC) were calculated. Adding DBT to FFDM significantly increased the detectability for recall cases and AUC relative to those of FFDM alone (HR mode 8.9 %; 95 % confidence interval (CI) 5.7, 15.0 %; P = 0.013 and 4.9 %; 95 % CI 2.1, 7.7 %; P = 0.001; ST mode 8.3 %; 95 % CI 4.1, 12.1 %; P = 0.007 and 2.9 %; 95 % CI 0.5, 5.3 %; P = 0.02), whereas the detectability for follow cases did not significantly differ. The AUC increase was significantly higher in HR mode than in ST mode (1.5 %; 95 % CI 0.5, 3.7 %; P = 0.023). Adding HR-mode or ST-mode DBT to FFDM significantly improved the detectability for diagnostic evaluation case.

  19. Dual Mode Offering As Viable Approach 
For Promotion Of Higher Education In Pakistan

    Directory of Open Access Journals (Sweden)

    Irshad HUSSAIN

    2014-01-01

    Full Text Available Pakistan is a developing with 148 universities and degree awarding institutions including public and private sector. The enrolment as given in the National Educational Policy 2009 was up to 5% only. It reflects greater demands of higher/tertiary education and calls for alternative strategic measures for addressing the issue. An innovative approach was necessary to address the issue of access. Therefore, the Islamia University of Bahawalpur –a formal mode university took an innovative initiative to become a dual mode university by establishing an Institute of Distance Education (IDE in 2011. The institute offered along with others, an M.Phill programme in ten disciplines through distance education mode in semester fall 2011. More than eight hundred applications were received by potential learners against 275 seats. However, after test and interview 189 students were enrolled in M.Phill programme in Applied Psychology, Arabic, Education, English, Media Studies, Islamic Studies, Pakistan Studies, History, Persian, and Urdu. In the beginning, the Institute organized an orientation workshop for learners to guide them studying in distance education system. The programme was offered under semester system and the semester was broke up into two halves –mid-term and final term. The respective departments provided learning materials to students whereas the IDE provided instructional booklet. Submission of two assignments was compulsory for the entire semester; one before mid-term and second before final-term workshop/ examination for each of the courses. Similarly, students’ presence in workshops for 24 hours (12 during mid-term and 12 during final-term workshop for one 3-credit hour course was mandatory. Students’ support services were provided through Skype conference, social media and mobile phones. Students necessarily had to give presentations and submit their assignments after checking their similarity index by using turnitin software. At the

  20. DUAL MODE OFFERING AS VIABLE APPROACH FOR PROMOTION OF HIGHER EDUCATION IN PAKISTAN

    Directory of Open Access Journals (Sweden)

    Irshad HUSSAIN

    2014-07-01

    Full Text Available Pakistan is a developing with 148 universities and degree awarding institutions including public and private sector. The enrolment as given in the National Educational Policy 2009 was up to 5% only. It reflects greater demands of higher/tertiary education and calls for alternative strategic measures for addressing the issue. An innovative approach was necessary to address the issue of access. Therefore, the Islamia University of Bahawalpur –a formal mode university took an innovative initiative to become a dual mode university by establishing an Institute of Distance Education (IDE in 2011. The institute offered along with others, an M.Phill programme in ten disciplines through distance education mode in semester fall 2011. More than eight hundred applications were received by potential learners against 275 seats. However, after test and interview 189 students were enrolled in M.Phill programme in Applied Psychology, Arabic, Education, English, Media Studies, Islamic Studies, Pakistan Studies, History, Persian, and Urdu. In the beginning, the Institute organized an orientation workshop for learners to guide them studying in distance education system. The programme was offered under semester system and the semester was broke up into two halves –mid-term and final term. The respective departments provided learning materials to students whereas the IDE provided instructional booklet. Submission of two assignments was compulsory for the entire semester; one before mid-term and second before final-term workshop/ examination for each of the courses. Similarly, students’ presence in workshops for 24 hours (12 during mid-term and 12 during final-term workshop for one 3-credit hour course was mandatory. Students’ support services were provided through Skype conference, social media and mobile phones. Students necessarily had to give presentations and submit their assignments after checking their similarity index by using turnitin software. At the

  1. A random phased-array for MR-guided transcranial ultrasound neuromodulation in non-human primates.

    Science.gov (United States)

    Chaplin, Vandiver; Phipps, Marshal A; Caskey, Charles F

    2018-04-18

    Transcranial focused ultrasound (FUS) is a non-invasive technique for therapy and study of brain neural activation. Here we report on the design and characterization of a new MR-guided FUS transducer for neuromodulation in non-human primates at 650 kHz. The array is randomized with 128 elements 6.6 mm in diameter, radius of curvature 7.2 cm, opening diameter 10.3 cm (focal ratio 0.7), and 46% coverage. Simulations were used to optimize transducer geometry with respect to focus size, grating lobes, and directivity. Focus size and grating lobes during electronic steering were quantified using hydrophone measurements in water and a three-axis stage. A novel combination of optical tracking and acoustic mapping enabled measurement of the 3D pressure distribution in the cortical region of an ex vivo skull to within ~3.5 mm of the surface, and allowed accurate modelling of the experiment via non-homogeneous 3D acoustic simulations. The data demonstrates acoustic focusing beyond the skull bone, with the focus slightly broadened and shifted proximal to the skull. The fabricated design is capable of targeting regions within the S1 sensorimotor cortex of macaques. © 2018 Institute of Physics and Engineering in Medicine.

  2. Inspection of copper canisters for spent nuclear fuel by means of ultrasound. Phased arrays, ultrasonic imaging and nonlinear acoustics

    International Nuclear Information System (INIS)

    Stepinski, Tadeusz; Ping Wu; Wennerstroem, Erik

    2004-09-01

    This report contains the research results concerning advanced ultrasound for the inspection of copper canisters for spent nuclear fuel obtained at Signals and Systems, Uppsala University in years 2003/2004. After a short introduction a review of beam forming fundamentals required for proper understanding phased array operation is included. The factors that determine lateral resolution during ultrasonic imaging of flaws in solids are analyzed and results of simulations modelling contact inspection of copper are presented. In the second chapter an improved synthetic aperture imaging (SAI) technique is introduced. The proposed SAI technique is characterized by an enhanced lateral resolution compared with the previously proposed extended synthetic aperture focusing technique (ESAFT). The enhancement of imaging performance is achieved due to more realistic assumption concerning the probability density function of scatterers in the region of interest. The proposed technique takes the form of a two-step algorithm using the result obtained in the first step as a prior for the second step. Final chapter contains summary of our recent experimental and theoretical research on nonlinear ultrasonics of unbounded interfaces. A new theoretical model for rough interfaces is developed, and the experimental results from the copper specimens that mimic contact cracks of different types are presented. Derivation of the theory and selected measurement results are given in appendix

  3. Probing the fundamental limit of niobium in high radiofrequency fields by dual mode excitation in superconducting radiofrequency cavities

    Energy Technology Data Exchange (ETDEWEB)

    Eremeev, Grigory; Geng, Rongli; Palczewski, Ari

    2011-07-01

    We have studied thermal breakdown in several multicell superconducting radiofrequency cavity by simultaneous excitation of two TM{sub 010} passband modes. Unlike measurements done in the past, which indicated a clear thermal nature of the breakdown, our measurements present a more complex picture with interplay of both thermal and magnetic effects. JLab LG-1 that we studied was limited at 40.5 MV/m, corresponding to B{sub peak} = 173 mT, in 8{pi}/9 mode. Dual mode measurements on this quench indicate that this quench is not purely magnetic, and so we conclude that this field is not the fundamental limit in SRF cavities.

  4. Improving the Pass-Band Return Loss in Liquid Crystal Dual-Mode Bandpass Filters by Microstrip Patch Reshaping

    OpenAIRE

    Torrecilla, Javier; Urruchi, Virginia; S?nchez-Pena, Jos? Manuel; Bennis, Noureddine; Garc?a, Alejandro; Segovia, Daniel

    2014-01-01

    In this paper, the design and experimental characterization of a tunable microstrip bandpass filter based on liquid crystal technology are presented. A reshaped microstrip dual-mode filter structure has been used in order to improve the device performance. Specifically, the aim is to increase the pass-band return loss of the filter by narrowing the filter bandwidth. Simulations confirm the improvement of using this new structure, achieving a pass-band return loss increase of 1.5 dB at least. ...

  5. A dual-mode signaling response of a AuNP-fluorescein based probe for specific detection of thiourea.

    Science.gov (United States)

    Chen, Chuanxia; Zhao, Dan; Sun, Jian; Yang, Xiurong

    2016-04-21

    By employing fluorescein and AuNPs as energy donors and acceptors, respectively, a novel fluorescence resonance energy transfer (FRET)-based dual-mode sensor for selective recognition and quantitative detection of thiourea was designed and constructed in this study for the first time. Herein, it is demonstrated that fluorescein could be adsorbed on the surface of AuNPs and induce fluorescence quenching through the well-known FRET process. The preferential introduction of thiourea would reduce the overall surface negative charges of AuNPs by replacing the original citrate groups, leading to the aggregation of AuNPs. Meanwhile, thiourea could prevent the binding between fluorescein and AuNPs, reduce the as-formed FRET effect, and then lead to fluorescence recovery of the fluorescein. Therefore, a dual-mode sensor with AuNP-related colorimetric and fluorescein-based fluorescence readout was rationally developed. Under the optimum conditions, the detection limits were calculated to be 10 nM and 23 nM for fluorescent and colorimetric sensors, individually, and a limit of 0.4 μM was detected by the naked eye. Finally, such a simple, convenient, cost-effective, highly selective and sensitive sensing assay was successfully applied in the detection of thiourea in tap water and fruit juice samples.

  6. A dual mode targeting probe for distinguishing HER2-positive breast cancer cells using silica-coated fluorescent magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jia [Medical School Southeast University, Department of Ultrasonography, Zhongda Hospital (China); An, Yan-Li; Zang, Feng-Chao [Southeast University, Jiangsu Key Laboratory of Molecular and Functional Imaging (China); Zong, Shen-Fei; Cui, Yi-Ping, E-mail: cyp@seu.edu.cn [Southeast University, Advanced Photonics Center (China); Teng, Gao-Jun, E-mail: gjteng@vip.sina.com [Southeast University, Jiangsu Key Laboratory of Molecular and Functional Imaging (China)

    2013-10-15

    We report a composite nanoprobe based on silica-coated magnetic nanoparticles (NPs) for distinguishing breast cancers at different HER2 statuses. The nanoprobe has a core-shell structure, with Fe{sub 3}O{sub 4} NPs as the magnetic core and dye-embedded silica as the fluorescent shell, whose average size is about 150 nm. Besides, the outmost surfaces of the probes were modified with specific antibodies to endow the probe with a targeting ability. With such a structure, the nanoprobe can accomplish dual mode targeting of human breast cancer cells based on fluorescence and magnetic resonance imaging (MRI). In the experiments, three human breast cancer cell lines were used to test the targeting ability of the nanoprobe. Specifically, SKBR3 cells with a high HER2 expression level were used as the model target cells, while MCF7 cells with a lower HER2 expression levels and HER2-negative MDA-MB-231 cells were used as the controls. Both the fluorescence and MRI imaging results confirmed that the nanoprobe can distinguish three cancer cell lines with different HER2 expression levels. With the dual mode imaging and specific targeting properties, we anticipate that the presented nanoprobe may have a great potential in the diagnosis and treatment of cancerous diseases.

  7. Use of conducting inductive meshes with periodic rectangle units as an infrared/microwave dual-mode detecting beamsplitter

    International Nuclear Information System (INIS)

    Liu, Yongmeng; Tan, Jiubin; Ma, Jing

    2011-01-01

    By optimizing the periods along the x and y axes of conducting inductive meshes with periodic rectangle units to minimize the differences in microwave reflectivity between the perpendicular and parallel polarizations, conducting inductive meshes with periodic rectangle units can be made useful as an infrared/microwave beamsplitter for the construction of a dual-mode detecting system. A conducting inductive rectangle-unit mesh beamsplitter is designed and fabricated using a laser directing writing technique. The microwave reflectivity and infrared transmissivity coefficients of the mesh beamsplitter sample are measured using a scalar network analyzer and a Fourier infrared spectrometer. Measurement and simulation results indicate that the microwave reflectivity and infrared transmissivity coefficients of infrared/microwave mesh beamsplitter are higher than − 1.5 dB and − 0.7 dB, respectively. It can therefore be concluded that conducting inductive meshes with periodic rectangle units can be used as an infrared/microwave beamsplitter in a dual-mode detecting system

  8. Multiple dual mode counter-current chromatography with periodic sample injection: Steady-state and non-steady-state operation.

    Science.gov (United States)

    Kostanyan, Artak E

    2014-12-19

    The multiple dual mode (MDM) counter-current chromatography (CCC) separation consists of a succession of two isocratic counter-current steps and is carried out in series alternating between normal phase and reversed phase operation. The performance of the MDM technique can be improved by the sample re-injection between each of the dual-mode steps. The objective of this work was to develop analytical expressions to describe the MDM CCC with periodic sample injection, which can be used to simulate these processes and select optimal operating conditions for the separation of a given feed mixture. Two possible methods of the MDM separation with periodic sample injection are considered: 1 - steady-state separation: the duration of the flow periods of the phases is kept constant for all the cycles and the steady-state regime is achieved after a certain number of cycles. 2 - non-steady-state separation with variable duration of phase elution steps. It is shown that proper selection of the duration of phase flow times allows to reach complete separation of solutes in continuous steady-state operation mode even in a low efficiency column. This mode of operation provides both high productivity and high resolution. The non-steady-state method with variable duration of phase elution steps offers several options to split a mixture into groups of compounds and/or concentrate target compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A dual mode targeting probe for distinguishing HER2-positive breast cancer cells using silica-coated fluorescent magnetic nanoparticles

    Science.gov (United States)

    Li, Jia; An, Yan-Li; Zang, Feng-Chao; Zong, Shen-Fei; Cui, Yi-Ping; Teng, Gao-Jun

    2013-10-01

    We report a composite nanoprobe based on silica-coated magnetic nanoparticles (NPs) for distinguishing breast cancers at different HER2 statuses. The nanoprobe has a core-shell structure, with Fe3O4 NPs as the magnetic core and dye-embedded silica as the fluorescent shell, whose average size is about 150 nm. Besides, the outmost surfaces of the probes were modified with specific antibodies to endow the probe with a targeting ability. With such a structure, the nanoprobe can accomplish dual mode targeting of human breast cancer cells based on fluorescence and magnetic resonance imaging (MRI). In the experiments, three human breast cancer cell lines were used to test the targeting ability of the nanoprobe. Specifically, SKBR3 cells with a high HER2 expression level were used as the model target cells, while MCF7 cells with a lower HER2 expression levels and HER2-negative MDA-MB-231 cells were used as the controls. Both the fluorescence and MRI imaging results confirmed that the nanoprobe can distinguish three cancer cell lines with different HER2 expression levels. With the dual mode imaging and specific targeting properties, we anticipate that the presented nanoprobe may have a great potential in the diagnosis and treatment of cancerous diseases.

  10. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  11. Phase-rotation based receive-beamformer for miniaturized volumetric ultrasound imaging scanners using 2-D CMUT-on-ASIC arrays

    Science.gov (United States)

    Kim, Bae-Hyung; Lee, Seunghun; Song, Jongkeun; Kim, Youngil; Jeon, Taeho; Cho, Kyungil

    2013-03-01

    Up-to-date capacitive micromachined ultrasonic transducer (CMUT) technologies provide us unique opportunities to minimize the size and cost of ultrasound scanners by integrating front-end circuits into CMUT arrays. We describe a design prototype of a portable ultrasound scan-head probe using 2-D phased CMUT-on-ASIC arrays of 3-MHz 250 micrometer-pitch by fabricating and integrating front-end electronics with 2-D CMUT array elements. One of the objectives of our work is to design a receive beamformer architecture for the smart probe with compact size and comparable performance. In this work, a phase-rotation based receive beamformer using the sampling frequency of 4 times the center frequency and a hybrid beamforming to reduce the channel counts of the system-side are introduced. Parallel beamforming is considered for the purpose of saving power consumption of battery (by firing fewer times per image frame). This architecture has the advantage of directly obtaining I and Q components. By using the architecture, the interleaved I/Q data from the storage is acquired and I/Q demodulation for baseband processing is directly achieved without demodulators including sin and cosine lookup tables and mixers. Currently, we are extending the presented architecture to develop a true smart probe by including lower power devices and cooling systems, and bringing wireless data transmission into consideration.

  12. Flexible integration of high-imaging-resolution and high-power arrays for ultrasound-induced thermal strain imaging (US-TSI).

    Science.gov (United States)

    Stephens, Douglas N; Mahmoud, Ahmed M; Ding, Xuan; Lucero, Steven; Dutta, Debaditya; Yu, Francois T H; Chen, Xucai; Kim, Kang

    2013-12-01

    Ultrasound-induced thermal strain imaging (USTSI) for carotid artery plaque detection requires both high imaging resolution (TSI in carotid plaque characterization, the tissue target site is 20 to 30 mm deep, with a typical target volume of 2 mm (elevation) × 8 mm (azimuthal) × 5 mm (depth). The custom heating array performance was fully characterized for two design variants (flat and spherical apertures), and can easily deliver 30 W of total acoustic power to produce intensities greater than 15 W/cm(2) in the tissue target region.

  13. Flexible Integration of Both High Imaging Resolution and High Power Arrays for Ultrasound-Induced Thermal Strain Imaging (US-TSI)

    Science.gov (United States)

    Stephens, Douglas N.; Mahmoud, Ahmed M.; Ding, Xuan; Lucero, Steven; Dutta, Debaditya; Yu, Francois T.H.; Chen, Xucai

    2013-01-01

    Ultrasound-induced thermal strain imaging (US-TSI) for carotid artery plaque detection requires both high imaging resolution (TSI on carotid plaque characterization, the tissue target site is 20 to 30 mm deep, with a typical target volume of 2 mm (elevation) × 8 mm (azimuthal) × 5 mm (depth). The custom heating array performance was fully characterized for two design variants (flat and spherical apertures), and can easily deliver 30 W of total acoustic power to produce intensities greater than 15 W/cm2 in tissue target region. PMID:24297029

  14. Dual-Mode Optical Sensing of Histamine at Nanomolar Concentrations in Complex Biological Fluids and Living Cells.

    Science.gov (United States)

    Dey, Nilanjan; Ali, Asfa; Podder, Santosh; Majumdar, Shamik; Nandi, Dipankar; Bhattacharya, Santanu

    2017-09-04

    An easily synthesized fluorescein-based luminescent dye has been utilized for the dual-mode detection of histamine at nanomolar concentrations at pH 7.0 in water. The specific response to histamine was achieved by imidazole-catalyzed 'imine formation' reaction. The protocol was subsequently applied for the estimation of histamine in complex biological milieu such as human blood serum and urine samples. Furthermore, the dose-dependent cellular uptake of histamine and de novo synthesis (by thapsigargin treatment) was visualized in RAW 264.7, a mouse macrophage cell line. We have also developed portable paper strips for rapid, on-site detection of histamine without involving costly instruments. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Improving the Pass-Band Return Loss in Liquid Crystal Dual-Mode Bandpass Filters by Microstrip Patch Reshaping

    Directory of Open Access Journals (Sweden)

    Javier Torrecilla

    2014-06-01

    Full Text Available In this paper, the design and experimental characterization of a tunable microstrip bandpass filter based on liquid crystal technology are presented. A reshaped microstrip dual-mode filter structure has been used in order to improve the device performance. Specifically, the aim is to increase the pass-band return loss of the filter by narrowing the filter bandwidth. Simulations confirm the improvement of using this new structure, achieving a pass-band return loss increase of 1.5 dB at least. Because of the anisotropic properties of LC molecules, a filter central frequency shift from 4.688 GHz to 5.045 GHz, which means a relative tuning range of 7.3%, is measured when an external AC voltage from 0 Vrms to 15 Vrms is applied to the device.

  16. Direct observation of the core/double-shell architecture of intense dual-mode luminescent tetragonal bipyramidal nanophosphors.

    Science.gov (United States)

    Kim, Su Yeon; Jeong, Jong Seok; Mkhoyan, K Andre; Jang, Ho Seong

    2016-05-21

    Highly efficient downconversion (DC) green-emitting LiYF4:Ce,Tb nanophosphors have been synthesized for bright dual-mode upconversion (UC) and DC green-emitting core/double-shell (C/D-S) nanophosphors-Li(Gd,Y)F4:Yb(18%),Er(2%)/LiYF4:Ce(15%),Tb(15%)/LiYF4-and the C/D-S structure has been proved by extensive scanning transmission electron microscopy (STEM) analysis. Colloidal LiYF4:Ce,Tb nanophosphors with a tetragonal bipyramidal shape are synthesized for the first time and they show intense DC green light via energy transfer from Ce(3+) to Tb(3+) under illumination with ultraviolet (UV) light. The LiYF4:Ce,Tb nanophosphors show 65 times higher photoluminescence intensity than LiYF4:Tb nanophosphors under illumination with UV light and the LiYF4:Ce,Tb is adapted into a luminescent shell of the tetragonal bipyramidal C/D-S nanophosphors. The formation of the DC shell on the core significantly enhances UC luminescence from the UC core under irradiation of near infrared light and concurrently generates DC luminescence from the core/shell nanophosphors under UV light. Coating with an inert inorganic shell further enhances the UC-DC dual-mode luminescence by suppressing the surface quenching effect. The C/D-S nanophosphors show 3.8% UC quantum efficiency (QE) at 239 W cm(-2) and 73.0 ± 0.1% DC QE. The designed C/D-S architecture in tetragonal bipyramidal nanophosphors is rigorously verified by an energy dispersive X-ray spectroscopy (EDX) analysis, with the assistance of line profile simulation, using an aberration-corrected scanning transmission electron microscope equipped with a high-efficiency EDX. The feasibility of these C/D-S nanophosphors for transparent display devices is also considered.

  17. Animacroxam, a Novel Dual-Mode Compound Targeting Histone Deacetylases and Cytoskeletal Integrity of Testicular Germ Cell Cancer Cells.

    Science.gov (United States)

    Steinemann, Gustav; Dittmer, Alexandra; Kuzyniak, Weronika; Hoffmann, Björn; Schrader, Mark; Schobert, Rainer; Biersack, Bernhard; Nitzsche, Bianca; Höpfner, Michael

    2017-11-01

    Novel approaches for the medical treatment of advanced solid tumors, including testicular germ cell tumors (TGCT), are desperately needed. Especially, TGCT patients not responding to cisplatin-based therapy need therapeutic alternatives, as there is no effective medical treatment available for this particular subgroup. Here, we studied the suitability of the novel dual-mode compound animacroxam for TGCT treatment. Animacroxam consists of an HDAC-inhibitory hydroxamate moiety coupled to a 4,5-diarylimidazole with inherent cytoskeleton disrupting potency. Animacroxam revealed pronounced antiproliferative, cell-cycle arresting, and apoptosis-inducing effects in TGCT cell lines with different cisplatin sensitivities. The IC 50 values of animacroxam ranged from 0.22 to 0.42 μmol/L and were not correlated to the cisplatin sensitivity of the tumor cells. No unspecific cytotoxicity of animacroxam was observed in either cisplatin-sensitive or resistant TGCT cells, even at doses as high as 10 μmol/L. Furthermore, animacroxam induced the formation of actin stress fibers in cancer cells, thereby confirming the cytoskeleton-disrupting and antimigratory properties of its imidazole moiety. When compared with the clinically established HDAC inhibitor vorinostat, the novel dual-mode compound animacroxam exhibited superior antitumoral efficacy in vitro Animacroxam also reduced the tumor size of TGCT tumors in vivo , as evidenced by performing xenograft experiments on tumor bearing chorioallantoic membranes of fertilizes chicken eggs (CAM assay). The in vivo experiments also revealed a very good tolerability of the compound, and hence, animacroxam may be a promising candidate for innovative treatment of TGCT in general and the more so for platinum-insensitive or refractory TGCT. Mol Cancer Ther; 16(11); 2364-74. ©2017 AACR . ©2017 American Association for Cancer Research.

  18. Dual-Mode Gas Sensor Composed of a Silicon Nanoribbon Field Effect Transistor and a Bulk Acoustic Wave Resonator: A Case Study in Freons.

    Science.gov (United States)

    Chang, Ye; Hui, Zhipeng; Wang, Xiayu; Qu, Hemi; Pang, Wei; Duan, Xuexin

    2018-01-25

    In this paper, we develop a novel dual-mode gas sensor system which comprises a silicon nanoribbon field effect transistor (Si-NR FET) and a film bulk acoustic resonator (FBAR). We investigate their sensing characteristics using polar and nonpolar organic compounds, and demonstrate that polarity has a significant effect on the response of the Si-NR FET sensor, and only a minor effect on the FBAR sensor. In this dual-mode system, qualitative discrimination can be achieved by analyzing polarity with the Si-NR FET and quantitative concentration information can be obtained using a polymer-coated FBAR with a detection limit at the ppm level. The complementary performance of the sensing elements provides higher analytical efficiency. Additionally, a dual mixture of two types of freons (CFC-113 and HCFC-141b) is further analyzed with the dual-mode gas sensor. Owing to the small size and complementary metal-oxide semiconductor (CMOS)-compatibility of the system, the dual-mode gas sensor shows potential as a portable integrated sensing system for the analysis of gas mixtures in the future.

  19. Dual mode linguistic hedge fuzzy logic controller for an isolated wind-diesel hybrid power system with superconducting magnetic energy storage unit

    International Nuclear Information System (INIS)

    Thameem Ansari, M.Md.; Velusami, S.

    2010-01-01

    A design of dual mode linguistic hedge fuzzy logic controller for an isolated wind-diesel hybrid power system with superconducting magnetic energy storage unit is proposed in this paper. The design methodology of dual mode linguistic hedge fuzzy logic controller is a hybrid model based on the concepts of linguistic hedges and hybrid genetic algorithm-simulated annealing algorithms. The linguistic hedge operators are used to adjust the shape of the system membership functions dynamically and can speed up the control result to fit the system demand. The hybrid genetic algorithm-simulated annealing algorithm is adopted to search the optimal linguistic hedge combination in the linguistic hedge module. Dual mode concept is also incorporated in the proposed controller because it can improve the system performance. The system with the proposed controller was simulated and the frequency deviation resulting from a step load disturbance is presented. The comparison of the proportional plus integral controller, fuzzy logic controller and the proposed dual mode linguistic hedge fuzzy logic controller shows that, with the application of the proposed controller, the system performance is improved significantly. The proposed controller is also found to be less sensitive to the changes in the parameters of the system and also robust under different operating modes of the hybrid power system.

  20. Dual-Mode Gas Sensor Composed of a Silicon Nanoribbon Field Effect Transistor and a Bulk Acoustic Wave Resonator: A Case Study in Freons

    Directory of Open Access Journals (Sweden)

    Ye Chang

    2018-01-01

    Full Text Available In this paper, we develop a novel dual-mode gas sensor system which comprises a silicon nanoribbon field effect transistor (Si-NR FET and a film bulk acoustic resonator (FBAR. We investigate their sensing characteristics using polar and nonpolar organic compounds, and demonstrate that polarity has a significant effect on the response of the Si-NR FET sensor, and only a minor effect on the FBAR sensor. In this dual-mode system, qualitative discrimination can be achieved by analyzing polarity with the Si-NR FET and quantitative concentration information can be obtained using a polymer-coated FBAR with a detection limit at the ppm level. The complementary performance of the sensing elements provides higher analytical efficiency. Additionally, a dual mixture of two types of freons (CFC-113 and HCFC-141b is further analyzed with the dual-mode gas sensor. Owing to the small size and complementary metal-oxide semiconductor (CMOS-compatibility of the system, the dual-mode gas sensor shows potential as a portable integrated sensing system for the analysis of gas mixtures in the future.

  1. Multistage depressed collector with efficiency of 90 to 94 percent for operation of a dual-mode traveling wave tube in the linear region

    Science.gov (United States)

    Ramins, P.; Fox, T. A.

    1980-01-01

    An axisymmetric, multistage, depressed collector of fixed geometric design was evaluated in conjunction with an octave bandwidth, dual mode traveling wave tube (TWT). The TWT was operated over a wide range of conditions to simulate different applications. The collector performance was optimized (within the constraint of fixed geometric design) over the range of TWT operating conditions covered. For operation of the TWT in the linear, low distortion range, 90 percent and greater collector efficiencies were obtained leading to TWT overall efficiencies of 20 to 35 percent, as compared with 2 to 5 percent with an undepressed collector. With collectors of this efficiency and minimized beam interception losses, it becomes practical to design dual mode TWT's such that the low mode can represent operation well below saturation. Consequently, the required pulse up in beam current can be reduced or eliminated, and this mitigates beam control and dual mode TWT circuit design problems. For operation of the dual mode TWT at saturation, average collector efficiencies in excess of 85 percent were obtained for both the low and high modes across an octave bandwidth, leading to a three to fourfold increase in the TWT overall efficiency.

  2. A high-frequency transimpedance amplifier for CMOS integrated 2D CMUT array towards 3D ultrasound imaging.

    Science.gov (United States)

    Huang, Xiwei; Cheong, Jia Hao; Cha, Hyouk-Kyu; Yu, Hongbin; Je, Minkyu; Yu, Hao

    2013-01-01

    One transimpedance amplifier based CMOS analog front-end (AFE) receiver is integrated with capacitive micromachined ultrasound transducers (CMUTs) towards high frequency 3D ultrasound imaging. Considering device specifications from CMUTs, the TIA is designed to amplify received signals from 17.5MHz to 52.5MHz with center frequency at 35MHz; and is fabricated in Global Foundry 0.18-µm 30-V high-voltage (HV) Bipolar/CMOS/DMOS (BCD) process. The measurement results show that the TIA with power-supply 6V can reach transimpedance gain of 61dBΩ and operating frequency from 17.5MHz to 100MHz. The measured input referred noise is 27.5pA/√Hz. Acoustic pulse-echo testing is conducted to demonstrate the receiving functionality of the designed 3D ultrasound imaging system.

  3. Dual-mode optical microscope based on single-pixel imaging

    Science.gov (United States)

    Rodríguez, A. D.; Clemente, P.; Tajahuerce, E.; Lancis, J.

    2016-07-01

    We demonstrate an inverted microscope that can image specimens in both reflection and transmission modes simultaneously with a single light source. The microscope utilizes a digital micromirror device (DMD) for patterned illumination altogether with two single-pixel photosensors for efficient light detection. The system, a scan-less device with no moving parts, works by sequential projection of a set of binary intensity patterns onto the sample that are codified onto a modified commercial DMD. Data to be displayed are geometrically transformed before written into a memory cell to cancel optical artifacts coming from the diamond-like shaped structure of the micromirror array. The 24-bit color depth of the display is fully exploited to increase the frame rate by a factor of 24, which makes the technique practicable for real samples. Our commercial DMD-based LED-illumination is cost effective and can be easily coupled as an add-on module for already existing inverted microscopes. The reflection and transmission information provided by our dual microscope complement each other and can be useful for imaging non-uniform samples and to prevent self-shadowing effects.

  4. Electromagnetic optimization of dual-mode antennas for radiometry-controlled heating of superficial tissue

    Science.gov (United States)

    Maccarini, Paolo F.; Rolfsnes, Hans O.; Neuman, Daniel G., Jr.; Johnson, Jessi E.; Juang, Titania; Jacobsen, Svein; Stauffer, Paul R.

    2005-04-01

    The large variance of survival in the treatment of large superficial tumors indicates that the efficacy of current therapies can be dramatically improved. Hyperthermia has shown significant enhancement of response when used in combination with chemotherapy and/or radiation. Control of temperature is a critical factor for treatment quality (and thus effectiveness), since the response of tumor and normal cells is significantly different over a range of just a few degrees (41-45°). For diffuse spreading tumors, microwave conformal arrays have been shown to be a sound solution to deposit the power necessary to reach the goal temperature throughout the targeted tissue. Continuous temperature monitoring is required for feedback control of power to compensate for physiologic (e.g. blood perfusion and dielectric properties) changes. Microwave radiometric thermometry has been proposed to complement individual fluoroptic probes to non-invasively map superficial and sub-surface temperatures. The challenge is to integrate the broadband antenna used for radiometric sensing with the high power antenna used for power deposition. A modified version of the dual concentric conductor antenna presented previously is optimized for such use. Several design challenges are presented including preventing unwanted radiating modes and thermal and electromagnetic coupling between the two antennas, and accommodating dielectric changes of the target tissue. Advanced 3D and planar 2D simulation software are used to achieve an initial optimized design, focused on maintaining appropriate radiation efficiency and pattern for both heating and radiometry antennas. A cutting edge automated measurement system has been realized to characterize the antennas in a tissue equivalent material and to confirm the simulation results. Finally, the guidelines for further development and improvement of this initial design are presented together with a preliminary implementation of the feedback program to be used

  5. Dual Mode Sensing with Low-Profile Piezoelectric Thin Wafer Sensors for Steel Bridge Crack Detection and Diagnosis

    Directory of Open Access Journals (Sweden)

    Lingyu Yu

    2012-01-01

    Full Text Available Monitoring of fatigue cracking in steel bridges is of high interest to many bridge owners and agencies. Due to the variety of deterioration sources and locations of bridge defects, there is currently no single method that can detect and address the potential sources globally. In this paper, we presented a dual mode sensing methodology integrating acoustic emission and ultrasonic wave inspection based on the use of low-profile piezoelectric wafer active sensors (PWAS. After introducing the research background and piezoelectric sensing principles, PWAS crack detection in passive acoustic emission mode is first presented. Their acoustic emission detection capability has been validated through both static and compact tension fatigue tests. With the use of coaxial cable wiring, PWAS AE signal quality has been improved. The active ultrasonic inspection is conducted by the damage index and wave imaging approach. The results in the paper show that such an integration of passive acoustic emission detection with active ultrasonic sensing is a technological leap forward from the current practice of periodic and subjective visual inspection and bridge management based primarily on history of past performance.

  6. Optical bistability in side-mode injection locked dual-mode Fabry-Pérot laser diode

    Directory of Open Access Journals (Sweden)

    Jian Wei Wu

    2013-08-01

    Full Text Available In this paper, optical bistability characteristics are demonstrated experimentally based on a dual-mode laser system comprising a multi-mode Fabry-Pérot laser diode (MMFP-LD and a built-in feedback cavity formed by a fiber facet. The results show that two lasing modes with frequency separation of ∼0.58 THz and comparable peak powers can be achieved by judicious adjustment of the bias current and the operating temperature of the laser chip, which has a peak fluctuation of less than ∼1 dBm over a measurement period of one hour. A combination of appropriate external injection power and wavelength detuning can result in remarkable optical bistability in two oscillation modes, in which the resulting contrast ratio between the unlocked and locked states can be up to 30 dB, and the corresponding hysteresis loop width can be changed by controlling the side-mode injection power and the wavelength detuning.

  7. Evaluation of dual-mode rainwater harvesting system to mitigate typhoon-induced water shortage in Taiwan.

    Science.gov (United States)

    Islam, M M; Chou, F N-F; Liaw, C-H

    2010-01-01

    The water shortage of today's world is one of the most challenging problems and the world is looking for the best solution to reduce it. Some human made causes and also natural causes are liable for the shortage of the existing water supply system. In Taiwan, especially during typhoon, the turbidity of raw water increases beyond the treatment level and the plant cannot supply required amount of water. To make the system effective, a couple of days are needed and the shortage occurs. The purpose of this study is to solve this emergency shortage problem. A dual-mode Rainwater Harvesting System (RWHS) was designed for this study as a supplement to the existing water supply system to support some selected non-potable components such as toilet and urinal flushing of an elementary school. An optimal design algorithm was developed using YAS (yield after spillage) and YBS (yield before spillage) release rules. The study result proved that an optimum volume of tank can solve the emergency water shortage properly. The system was found to be more reliable in Taipei area than that of Tainan area. The study also discovered that a government subsidy would be needed to promote the system in Taiwan.

  8. Terminalia Chebula provides protection against dual modes of necroptotic and apoptotic cell death upon death receptor ligation.

    Science.gov (United States)

    Lee, Yoonjung; Byun, Hee Sun; Seok, Jeong Ho; Park, Kyeong Ah; Won, Minho; Seo, Wonhyoung; Lee, So-Ra; Kang, Kidong; Sohn, Kyung-Cheol; Lee, Ill Young; Kim, Hyeong-Geug; Son, Chang Gue; Shen, Han-Ming; Hur, Gang Min

    2016-04-27

    Death receptor (DR) ligation elicits two different modes of cell death (necroptosis and apoptosis) depending on the cellular context. By screening a plant extract library from cells undergoing necroptosis or apoptosis, we identified a water extract of Terminalia chebula (WETC) as a novel and potent dual inhibitor of DR-mediated cell death. Investigation of the underlying mechanisms of its anti-necroptotic and anti-apoptotic action revealed that WETC or its constituents (e.g., gallic acid) protected against tumor necrosis factor-induced necroptosis via the suppression of TNF-induced ROS without affecting the upstream signaling events. Surprisingly, WETC also provided protection against DR-mediated apoptosis by inhibition of the caspase cascade. Furthermore, it activated the autophagy pathway via suppression of mTOR. Of the WETC constituents, punicalagin and geraniin appeared to possess the most potent anti-apoptotic and autophagy activation effect. Importantly, blockage of autophagy with pharmacological inhibitors or genetic silencing of Atg5 selectively abolished the anti-apoptotic function of WETC. These results suggest that WETC protects against dual modes of cell death upon DR ligation. Therefore, WETC might serve as a potential treatment for diseases characterized by aberrantly sensitized apoptotic or non-apoptotic signaling cascades.

  9. Dual-mode optical fiber-based tweezers for robust trapping and manipulation of absorbing particles in air

    Science.gov (United States)

    Sil, Souvik; Kanti Saha, Tushar; Kumar, Avinash; Bera, Sudipta K.; Banerjee, Ayan

    2017-12-01

    We develop an optical tweezers system using a single dual-mode optical fiber where mesoscopic absorbing particles can be trapped in three dimensions and manipulated employing photophoretic forces. We generate a superposition of fundamental and first order Hermite-Gaussian beam modes by the simple innovation of coupling a laser into a commercial optical fiber designed to be single mode for a wavelength higher than that of the laser. We achieve robust trapping of the absorbing particles for hours using both the pure fundamental and superposition mode beams and attain large manipulation velocities of ˜5 mm s-1 in the axial direction and ˜0.75 mm s-1 in the radial direction. We then demonstrate that the superposition mode is more effective in trapping and manipulation compared to the fundamental mode by around 80%, which may be increased several times by the use of a pure first order Hermite-Gaussian mode. The work has promising implications for trapping and spectroscopy of aerosols in air using simple optical fiber-based traps.

  10. Three-Input Single-Output Electronically Controllable Dual-Mode Universal Biquad Filter Using DO-CCCIIs

    Directory of Open Access Journals (Sweden)

    M. Siripruchyanun

    2007-01-01

    Full Text Available This article presents a dual-mode (voltage-mode and current-mode universal biquadratic filter performing completely standard functions: lowpass, highpass, bandpass, band-reject, and allpass functions, based on plus-type dual-output second-generation, current controlled, current conveyor (DO-CCCII+. The features of the circuit are that the bandwidth and natural frequency can be tuned electronically via the input bias currents: the circuit description is very simple, consisting of merely 2 DO-CCCIIs and 2 capacitors: the circuit can provide either the voltage-mode or current-mode filter without changing circuit topology. Additionally, each function response can be selected by suitably selecting input signals with digital method. Without any external resistors, the proposed circuit is very suitable to further develop into an integrated circuit. The PSPICE simulation results are depicted. The given results agree well with the theoretical anticipation. The maximum power consumption is approximately 1.81 mW at ±1.5 V supply voltages.

  11. A Compact High-Pass Filter Using Hybrid Microstrip/Nonuniform CPW with Dual-Mode Resonant Response

    Directory of Open Access Journals (Sweden)

    Hui Chen

    2016-01-01

    Full Text Available A novel and miniature high-pass filter (HPF based on a hybrid-coupled microstrip/nonuniform coplanar waveguide (CPW resonator is proposed in this article, in which the designed CPW has exhibited a wideband dual-mode characteristic within the desired high-pass frequency range. The implemented filter consists of the top microstrip coupled patches and the bottom modified nonuniformly short-circuited CPW resonator. Simulated results from the electromagnetic (EM analysis software and measured results from a vector network analyzer (VNA show a good agreement. A designed and fabricated prototype filter having a 3 dB cutoff frequency (fc of 5.78 GHz has shown an ultrawide high-pass behavior, which exhibits the highest passband frequency exceeding 4.0fc under the minimum insertion loss (IL 0.75 dB. The printed circuit board (PCB area of the filter is approximately 0.062λg×0.093λg, where λg is the guided wavelength at fc.

  12. Application of AirCell Cellular AMPS Network and Iridium Satellite System Dual Mode Service to Air Traffic Management

    Science.gov (United States)

    Shamma, Mohammed A.

    2004-01-01

    The AirCell/Iridium dual mode service is evaluated for potential applications to Air Traffic Management (ATM) communication needs. The AirCell system which is largely based on the Advanced Mobile Phone System (AMPS) technology, and the Iridium FDMA/TDMA system largely based on the Global System for Mobile Communications(GSM) technology, can both provide communication relief for existing or future aeronautical communication links. Both have a potential to serve as experimental platforms for future technologies via a cost effective approach. The two systems are well established in the entire CONUS and globally hence making it feasible to utilize in all regions, for all altitudes, and all classes of aircraft. Both systems have been certified for air usage. The paper summarizes the specifications of the AirCell/Iridium system, as well as the ATM current and future links, and application specifications. the paper highlights the scenarios, applications, and conditions under which the AirCell/Iridium technology can be suited for ATM Communication.

  13. A dual-mode single-molecule fluorescence assay for the detection of expanded CGG repeats in Fragile X syndrome.

    Science.gov (United States)

    Cannon, Brian; Pan, Cynthia; Chen, Liangjing; Hadd, Andrew G; Russell, Rick

    2013-01-01

    Fragile X syndrome is the leading cause of inherited mental impairment and is associated with expansions of CGG repeats within the FMR1 gene. To detect expanded CGG repeats, we developed a dual-mode single-molecule fluorescence assay that allows acquisition of two parallel, independent measures of repeat number based on (1) the number of Cy3-labeled probes bound to the repeat region and (2) the physical length of the electric field-linearized repeat region, obtained from the relative position of a single Cy5 dye near the end of the repeat region. Using target strands derived from cell-line DNA with defined numbers of CGG repeats, we show that this assay can rapidly and simultaneously measure the repeats of a collection of individual sample strands within a single field of view. With a low occurrence of false positives, the assay differentiated normal CGG repeat lengths (CGG( N ), N = 23) and expanded CGG repeat lengths (CGG( N ), N = 118), representing a premutation disease state. Further, mixtures of these DNAs gave results that correlated with their relative populations. This strategy may be useful for identifying heterozygosity or for screening collections of individuals, and it is readily adaptable for screening other repeat disorders.

  14. Multiple player tracking in sports video: a dual-mode two-way bayesian inference approach with progressive observation modeling.

    Science.gov (United States)

    Xing, Junliang; Ai, Haizhou; Liu, Liwei; Lao, Shihong

    2011-06-01

    Multiple object tracking (MOT) is a very challenging task yet of fundamental importance for many practical applications. In this paper, we focus on the problem of tracking multiple players in sports video which is even more difficult due to the abrupt movements of players and their complex interactions. To handle the difficulties in this problem, we present a new MOT algorithm which contributes both in the observation modeling level and in the tracking strategy level. For the observation modeling, we develop a progressive observation modeling process that is able to provide strong tracking observations and greatly facilitate the tracking task. For the tracking strategy, we propose a dual-mode two-way Bayesian inference approach which dynamically switches between an offline general model and an online dedicated model to deal with single isolated object tracking and multiple occluded object tracking integrally by forward filtering and backward smoothing. Extensive experiments on different kinds of sports videos, including football, basketball, as well as hockey, demonstrate the effectiveness and efficiency of the proposed method.

  15. Dual-Band Dual-Mode Button Antenna for On-Body and Off-Body Communications.

    Science.gov (United States)

    Zhang, Xiu Yin; Wong, Hang; Mo, Te; Cao, Yun Fei

    2017-08-01

    A dual-band dual-mode button antenna for body centric communications is presented. At the lower band, a spiral inverted-F antenna is designed with omnidirectional radiation pattern for on-body communication. At the upper band, the high-order mode of the inverted-F antenna is utilized together with a metal reflector to realize broadside radiation for off-body communication. For demonstration, a prototype is implemented. The measured peak gains on the phantom at the lower and upper bands are -0.6 and 4.3 dBi, respectively. The antenna operating on the phantom has measured efficiencies of 46.3% at the lower band and 69.3% at the upper band. The issue of specific absorption rate (SAR) is studied. The maximum transmitted power under the SAR regulation of 1.6 W/kg is found to be 26.4 dB·m, which is high enough for body centric communications. In addition, the transmission performance between two proposed antennas mounted on the body is investigated by measuring the transmission loss. With an overall miniaturized size, the robust button antenna could be integrated in clothes and be a potential candidate for wireless body area network applications.

  16. RADIOISOTOPE-DRIVEN DUAL-MODE PROPULSION SYSTEM FOR CUBESAT-SCALE PAYLOADS TO THE OUTER PLANETS

    Energy Technology Data Exchange (ETDEWEB)

    N. D. Jerred; T. M. Howe; S. D. Howe; A. Rajguru

    2014-02-01

    It is apparent the cost of planetary exploration is rising as mission budgets declining. Currently small scientific beds geared to performing limited tasks are being developed and launched into low earth orbit (LEO) in the form of small-scale satellite units, i.e., CubeSats. These micro- and nano-satellites are gaining popularity among the university and science communities due to their relatively low cost and design flexibility. To date these small units have been limited to performing tasks in LEO utilizing solar-based power. If a reasonable propulsion system could be developed, these CubeSat platforms could perform exploration of various extra-terrestrial bodies within the solar system engaging a broader range of researchers. Additionally, being mindful of mass, smaller cheaper launch vehicles (approximately 1,000 kgs to LEO) can be targeted. Thus, in effect, allows for beneficial exploration to be conducted within limited budgets. Researchers at the Center for Space Nuclear Research (CSNR) are proposing a low mass, radioisotope-based, dual-mode propulsion system capable of extending the exploration realm of these CubeSats out of LEO.

  17. A Priori Analysis of a Compressible Flamelet Model using RANS Data for a Dual-Mode Scramjet Combustor

    Science.gov (United States)

    Quinlan, Jesse R.; Drozda, Tomasz G.; McDaniel, James C.; Lacaze, Guilhem; Oefelein, Joseph

    2015-01-01

    In an effort to make large eddy simulation of hydrocarbon-fueled scramjet combustors more computationally accessible using realistic chemical reaction mechanisms, a compressible flamelet/progress variable (FPV) model was proposed that extends current FPV model formulations to high-speed, compressible flows. Development of this model relied on observations garnered from an a priori analysis of the Reynolds-Averaged Navier-Stokes (RANS) data obtained for the Hypersonic International Flight Research and Experimentation (HI-FiRE) dual-mode scramjet combustor. The RANS data were obtained using a reduced chemical mechanism for the combustion of a JP-7 surrogate and were validated using avail- able experimental data. These RANS data were then post-processed to obtain, in an a priori fashion, the scalar fields corresponding to an FPV-based modeling approach. In the current work, in addition to the proposed compressible flamelet model, a standard incompressible FPV model was also considered. Several candidate progress variables were investigated for their ability to recover static temperature and major and minor product species. The effects of pressure and temperature on the tabulated progress variable source term were characterized, and model coupling terms embedded in the Reynolds- averaged Navier-Stokes equations were studied. Finally, results for the novel compressible flamelet/progress variable model were presented to demonstrate the improvement attained by modeling the effects of pressure and flamelet boundary conditions on the combustion.

  18. 3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Jensen, Jørgen Arendt

    2013-01-01

    This paper compares the imaging performance of a 128+128 element row-column addressed array with a fully addressed 1616 2D array. The comparison is made via simulations of the point spread function with Field II. Both arrays have lambda-pitch, a center frequency of 3:5MHz and use 256 active...... elements. The row-column addressed array uses 128 transmit channels and 128 receive channels, whereas the fully addressed array uses 256 channels in both transmit and receive. The large size of the emulated row and column elements in the row-column addressed array causes ghost echoes to appear. The ghost...... echoes are shown to be suppressed when the sub-elements within each of the emulated row and column elements are apodized. The maximum ghost intensity is suppressed by 22:2 dB compared to using no apodization. With apodization applied, the full-width-at-half-maximum in the lateral direction for the fully...

  19. Dual-Mode Luminescent Nanopaper Based on Ultrathin g-C3N4 Nanosheets Grafted with Rare-Earth Upconversion Nanoparticles.

    Science.gov (United States)

    Zhao, Yafei; Wei, Ruoyan; Feng, Xin; Sun, Lining; Liu, Panpan; Su, Yongxiang; Shi, Liyi

    2016-08-24

    Ultrathin graphite-like carbon nitride (g-C3N4) nanosheets have attracted considerable attention due to the enhanced intrinsic photoabsorption and photoresponse with respect to bulk g-C3N4. For the first time, a dual-mode of down- and upconversion luminescent g-C3N4 nanopaper with high optical transparency and mechanical robustness was successfully fabricated through a simple thermal evaporation process using chitosan as a green cross-linking agent. The dual-mode of down- and upconversion fluorescence emission originated from the amino terminated ultrathin g-C3N4 nanosheets functionalized with carboxylic acid modified multicolored rare-earth upconversion nanoparticles (cit-UCNPs) via EDC/NHS coupling chemistry. The homogeneously distributed cit-UCNPs@g-C3N4 nanoconjugates with excellent hydrophilicity displayed good film-forming ability and structural integrity; thus, the photoluminescence of each ingredient was substantially maintained. Results indicated that the freestanding chitosan cross-linked cit-UCNPs@g-C3N4 luminescent nanopaper possessed high transmittance, excellent mechanical properties, and remarkable dual-mode emission. The smart design of high performance luminescent nanopaper based on ultrathin g-C3N4 nanosheets grafted with multicolored UCNPs offers a potential strategy to immobilize other multifunctional luminescent materials for easily recognizable and hardly replicable anticounterfeiting fields.

  20. Multifunctional MWCNTs-NaGdF4:Yb(3+),Er(3+),Eu(3+) hybrid nanocomposites with potential dual-mode luminescence, magnetism and photothermal properties.

    Science.gov (United States)

    Liu, Wenjia; Liu, Guixia; Dong, Xiangting; Wang, Jinxian; Yu, Wensheng

    2015-09-21

    A novel dual-mode luminescence multifunctional hybrid nanomaterial has been successfully prepared by coating the NaGdF4:Yb(3+),Er(3+),Eu(3+) nanoparticles (NPs) on the surface of MWCNTs. The as-synthesized MWCNTs-NaGdF4:Yb(3+),Er(3+),Eu(3+) nanocomposites (NCs) can simultaneously take advantage of both magnetic and optical properties of NaGdF4:Yb(3+),Er(3+),Eu(3+) NPs and the photothermal conversion property of MWCNTs. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDS), vibrating sample magnetometry (VSM), UV-Vis absorption, luminescence spectroscopy and fluorescence lifetime measurements. Meanwhile, the photothermal conversion was examined under irradiation with a 980 nm laser. The results show that the MWCNTs-NaGdF4:Yb(3+),Er(3+),Eu(3+) NCs have preferably magnetic, dual-mode (up- and down-conversion) luminescence and photothermal properties. And the NCs have good biocompatibility, low toxicity and up-conversion luminescence for cell imaging. As a consequence, the dual-mode luminescence multifunctional nanomaterials have potential applications in environmental science fields and clinical fields for magnetic resonance imaging, fluorescence imaging, photothermal therapy, bioseparation and targeted drug delivery.

  1. Dual-Mode Dual-Band Microstrip Bandpass Filter Based on Fourth Iteration T-Square Fractal and Shorting Pin

    Directory of Open Access Journals (Sweden)

    E. S. Ahmed

    2012-06-01

    Full Text Available A new class of dual mode microstrip fractal resonator is proposed and developed for miniaturization of the dual band bandpass filter. The perimeter of the proposed resonator is increased by employing fourth iteration T-square fractal shape. Consequently the lower resonant frequency of the filter is decreased without increasing the usable space. The self similarity of the usable structure enables it to produce the two degenerate modes which are coupled using the proper perturbation technique. The shorting pin is placed at the null in the surface current distribution at the center of the resonator. This shorting pin is coactively coupled to the resonant circuit of the resonator, effectively coupled to the lower degenerate mode and reduces the lower edge band resonant frequency. By adjusting the resonator dimensions and the size of the shorting pin, the resonant frequency and the out-of-band rejection around the transmission bands can be controlled to meet the design requirements. The simulated response of the designed filter has two transmission bands, the first band is from 2.34-3.65 GHz with resonant frequencies at 2.47GHz and 3.55GHz, the second band is from 4.37-5.324GHz with resonant frequencies at 4.5GHz and 5.13GHz. In the pass bands, the group delay is less than 0.65 ns. The proposed filter can be applied to WLAN (2.4 GHz and 5.2 GHz and WiMAX (3.5 GHz and Bluetooth and ZigBee (4.9 GHz.

  2. Implementation of high-resolution SNP arrays in the investigation of fetuses with ultrasound malformations: 5 years of clinical experience.

    Science.gov (United States)

    Liao, C; Fu, F; Li, R; Xie, G-E; Zhang, Y-L; Li, J; Li, D-Z

    2014-09-01

    Chromosome microarray analysis (CMA) has proven to be a powerful tool in postnatal patients with intellectual disabilities, and it is increasingly used in prenatal diagnosis. However, its diagnostic capabilities in prenatal diagnosis vary, and clinical experiences have failed to establish a consensus regarding CMA indications, the design and resolution of microarrays, and the notification and interpretation of copy number variations (CNVs). We present our 5 years of clinical experience using whole-genome high-resolution single nucleotide polymorphism (SNP) arrays to investigate 446 fetuses that had structural malformations detected with ultrasound but for which standard karyotyping analysis showed normal karyotypes. CMA revealed genomic CNVs in 323 (72.4%) cases and clinically significant CNVs in 11.4% of the fetuses (51/446), including 2 cases of uniparental disomy (UPD) as well as 1 case of cryptic mosaic monosomy of chromosome X. Variants of unknown significance (VOUS) existed in 2.0% of the tested fetuses (9/446). Our results demonstrate the value of whole-genome high-resolution SNP arrays in fetuses with congenital malformations and give a higher detection rate of clinically significant genomic imbalance, especially for detecting UPD. Sufficient communication between technicians and genetic counselors, along with parental testing and comparison with data from in-house or international sources, can significantly reduce VOUS. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  4. Remote heterodyne millimeter-wave over fiber based OFDM-PON with master-to-slave injected dual-mode colorless FPLD pair.

    Science.gov (United States)

    Chen, Hsiang-Yu; Chi, Yu-Chieh; Lin, Gong-Ru

    2015-08-24

    A remote heterodyne millimeter-wave (MMW) carrier at 47.7 GHz over fiber synthesized with the master-to-slave injected dual-mode colorless FPLD pair is proposed, which enables the future connection between the wired fiber-optic 64-QAM OFDM-PON at 24 Gb/s with the MMW 4-QAM OFDM wireless network at 2 Gb/s. Both the single- and dual-mode master-to-slave injection-locked colorless FPLD pairs are compared to optimize the proposed 64-QAM OFDM-PON. For the unamplified single-mode master, the slave colorless FPLD successfully performs the 64-QAM OFDM data at 24 Gb/s with EVM, SNR and BER of 8.5%, 21.5 dB and 2.9 × 10(-3), respectively. In contrast, the dual-mode master-to-slave injection-locked colorless FPLD pair with amplified and unfiltered master can transmit 64-QAM OFDM data at 18 Gb/s over 25-km SMF to provide EVM, SNR and BER of 8.2%, 21.8 dB and 2.2 × 10(-3), respectively. For the dual-mode master-to-slave injection-locked colorless FPLD pair, even though the modal dispersion occurred during 25-km SMF transmission makes it sacrifice the usable OFDM bandwidth by only 1 GHz, which guarantees the sufficient encoding bitrate for the optically generated MMW carrier to implement the fusion of MMW wireless LAN and DWDM-PON with cost-effective and compact architecture. As a result, the 47.7-GHz MMW carrier remotely beat from the dual-mode master-to-slave injection-locked colorless FPLD pair exhibits an extremely narrow bandwidth of only 0.48 MHz. After frequency down-conversion operation, the 47.7-GHz MMW carrier successfully delivers 4-QAM OFDM data up to 2 Gb/s with EVM, SNR and BER of 33.5%, 9.51 dB and 1.4 × 10(-3), respectively.

  5. Designing a dual-mode broadband solar spectral converter: The example of Bi{sup 3+}, Cr{sup 3+}, Yb{sup 3+}-tridoped perovskite

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Li-Tian; Wu, Xuan-Ming; Wang, Ting; Chen, Dong-Ju; Deng, Chao; Meng, Jian-Xin, E-mail: tmjx@jnu.edu.cn; Cao, Li-Wei

    2016-07-15

    A promising dual-mode broadband solar spectral converter CaTiO{sub 3}: Bi{sup 3+}, Cr{sup 3+}, Yb{sup 3+} was successfully developed by solid-stated reaction. The structure, photoluminescence (PL), photoluminescence excitation (PLE) and diffuse reflectance (DR) spectra in the UV–vis–NIR region have been systematically investigated. The results show that the as-prepared samples simultaneously exhibit two distinct spectral converting patterns, nonlinear quantum-cutting (QC) involving Bi{sup 3+}–Ti{sup 4+} metal-to-metal charge transfer state (BT-MMCTs) → Yb{sup 3+}: {sup 2}F{sub 5/2} + Yb{sup 3+}: {sup 2}F{sub 5/2} and linear downshift (DS) involving Cr{sup 3+}: {sup 4}T{sub 2} → Yb{sup 3+}: {sup 2}F{sub 5/2}. It deduces that the nonlinear QC is based on a cooperative energy transfer (CET) process while the linear DS belongs to a dipole–dipole mechanism. With the present converter, broadband UV–vis (300–700 nm) photons, which are not fully utilized by the existing c-Si solar cells, can be efficiently harvested and converted into ∼1000 nm NIR photons via the dual-mode mechanism. Moreover, not only the PLE spectrum of CaTiO{sub 3}: Bi{sup 3+}, Cr{sup 3+}, Yb{sup 3+} matched well with that of the solar radiation, but also its NIR emission peak position fell well over the spectral response of the commercial crystalline Si (c-Si) solar cells. This as-prepared dual-mode solar spectral converter with multiple advantages can simultaneously realize high quantum yield and broadband conversion, which offers a new and effective way to boost the conversion efficiency of c-Si solar cells. We believe this novel design of dual-mode solar spectral converters can inspire a direction for the synthesis of more advanced UV–vis–NIR phosphors that can be used in Si solar cells. - Highlights: • A dual-mode broadband solar spectral converter is designed and developed. • The energy transfer mechanism relies on quantum-cutting as well as downshift. • The PLE

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  9. Circumferential lesion formation around the pulmonary veins in the left atrium with focused ultrasound using a 2D-array endoesophageal device: a numerical study

    Energy Technology Data Exchange (ETDEWEB)

    Pichardo, Samuel; Hynynen, Kullervo [Imaging Research-Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Room C713, Toronto, ON M4N 3M5 (Canada)

    2007-08-21

    Atrial fibrillation (AF) is the most frequently sustained cardiac arrhythmia affecting humans. The electrical isolation by ablation of the pulmonary veins (PVs) in the left atrium (LA) of the heart has been proven as an effective cure of AF. The ablation consists mainly in the formation of a localized circumferential thermal coagulation of the cardiac tissue surrounding the PVs. In the present numerical study, the feasibility of producing the required circumferential lesion with an endoesophageal ultrasound probe is investigated. The probe operates at 1 MHz and consists of a 2D array with enough elements (114 x 20) to steer the acoustic field electronically in a volume comparable to the LA. Realistic anatomical conditions of the thorax were considered from the segmentation of histological images of the thorax. The cardiac muscle and the blood-filled cavities in the heart were identified and considered in the sound propagation and thermal models. The influence of different conditions of the thermal sinking in the LA chamber was also studied. The circumferential ablation of the PVs was achieved by the sum of individual lesions induced with the proposed device. Different scenarios of lesion formation were considered where ultrasound exposures (1, 2, 5 and 10 s) were combined with maximal peak temperatures (60, 70 and 80 {sup 0}C). The results of this numerical study allowed identifying the limits and best conditions for controlled lesion formation in the LA using the proposed device. A controlled situation for the lesion formation surrounding the PVs was obtained when the targets were located within a distance from the device in the range of 26 {+-} 7 mm. When combined with a maximal temperature of 70 {sup 0}C and an exposure time between 5 and 10 s, this distance ensured preservation of the esophageal structures, controlled lesion formation and delivery of an acoustic intensity at the transducer surface that is compatible with existing materials. With a peak

  10. An analog-digital hybrid RX beamformer chip with non-uniform sampling for ultrasound medical imaging with 2D CMUT array.

    Science.gov (United States)

    Um, Ji-Yong; Kim, Yoon-Jee; Cho, Seong-Eun; Chae, Min-Kyun; Song, Jongkeun; Kim, Baehyung; Lee, Seunghun; Bang, Jihoon; Kim, Youngil; Cho, Kyungil; Kim, Byungsub; Sim, Jae-Yoon; Park, Hong-June

    2014-12-01

    To reduce the memory area, a two-stage RX beamformer (BF) chip with 64 channels is proposed for the ultrasound medical imaging with a 2D CMUT array. The chip retrieved successfully two B-mode phantom images with a steering angle from -45 (°) to +45 (°), the maximum delay range of 8 μs, and the delay resolution of 6.25 ns. An analog-digital hybrid BF (HBF) is chosen for the proposed chip to utilize the easy beamforming operation in the digital domain and also to reduce chip area by minimizing the number of ADCs. The chip consists of eight analog beamformers (ABF) for the 1st-stage and a digital beamformer (DBF) for the 2nd-stage. The two-stage architecture reduces the memory area of both ABF and DBF by around four times. The DBF circuit is divided into three steps to further reduce the digital FIFO memory area by around twice. Coupled with the non-uniform sampling scheme, the proposed two-stage HBF chip reduces the total memory area by around 40 times compared to the uniform-sampling single-stage BF chip. The chip fabricated in a 0.13- μm CMOS process occupies the area of 19.4 mm(2), and dissipates 1.14 W with the analog supply of 3.3 V and the digital supply of 1.2 V.

  11. Ultrasound-assisted solid-phase extraction coupled with photodiode-array and fluorescence detection for chemotaxonomy of isoflavone phytoestrogens in Trifolium L. (Clover) species.

    Science.gov (United States)

    Zgórka, Grazyna

    2009-04-01

    Detailed chemotaxonomic studies were undertaken to establish the qualitative profile and real amounts of the pharmacologically active isoflavone aglycones genistein, daidzein, formononetin, and biochanin A in aerial parts of thirteen Trifolium L. (clover) species, native to Poland. A newly elaborated micropreparative technique--SPE--on BakerBond octadecyl, cyclohexyl, and phenyl cartridges was used in combination with ultrasound-assisted extraction for isolation of isoflavone aglycones from hydrolyzed samples. The effectiveness of all three SPE sorbents in the purification of plant extracts was compared and very high recoveries (>96%) were documented for four isoflavones. Classical photodiode-array and very sensitive fluorescence detection, coupled with reversed-phase high-performance liquid chromatography (RP-HPLC), were employed to obtain the most reliable qualitative and quantitative results. Chemotaxonomic differences combined with flower color variability were demonstrated within thirteen clover species. Concentration levels of particular isoflavones in ten Trifolium species possessing flowers with white, pink, or purple-red corolla ranged from approximately 3 to approximately 3300 microg/g dry weight, while in three yellow flowering clovers (T. aureum, T. dubium, and T. campestre) isoflavone compounds have not been detected at all. RSD values, determined for intra- and inter-day precision of the quantitative results, were not higher than 6.2% and 7.1%, respectively.

  12. Mathematical model for the preliminary analysis of dual-mode space nuclear fission solid core power and propulsion systems, NUROC3A. AMS report No. 1239a

    Energy Technology Data Exchange (ETDEWEB)

    Grey, J.; Chow, S.

    1976-06-30

    The three-volume report describes a dual-mode nuclear space power and propulsion system concept that employs an advanced solid-core nuclear fission reactor coupled via heat pipes to one of several electric power conversion systems. Such a concept could be particularly useful for missions which require both relatively high acceleration (e.g., for planetocentric maneuvers) and high performance at low acceleration (e.g., on heliocentric trajectories or for trajectory shaping). The first volume develops the mathematical model of the system.

  13. Characterization of Monomeric MnII/III/IV–Hydroxo Complexes from X- and Q-Band Dual Mode Electron Paramagnetic Resonance (EPR) Spectroscopy

    OpenAIRE

    Gupta, Rupal; Taguchi, Taketo; Borovik, A. S.; Hendrich, Michael P.

    2013-01-01

    Manganese–hydroxo species have been implicated in C–H bond activation performed by metalloenzymes, but the electronic properties of many of these intermediates are not well characterized. The present work presents a detailed characterization of three Mnn–OH complexes (where n = II, III, and IV) of the tris[(N′-tert-butylureaylato)-N-ethylene]aminato ([H3buea]3−) ligand using X- and Q-band dual mode electron paramagnetic resonance (EPR). Quantitative simulations for the [MnIIH3buea(OH)]2− comp...

  14. A MEMS and agile optics-based dual-mode variable optical power splitter with no moving parts

    Science.gov (United States)

    Khwaja, Tariq S.; Suleman, Hamid; Reza, Syed Azer

    2017-06-01

    In this paper, we present a novel design of an optical power splitter. Owing to the inherent variable power split ratios that the proposed design delivers, it is ideal for use in communications, sensing and signal processing applications where variable power splitting is often quintessential. The proposed power splitter module is dual mode as it combines the use of a Micro-Electro-Mechanical Systems (MEMS) based Digital Micro-mirror Device (DMD) and an Electronically Controlled Tunable Lens (ECTL) to split the power of an input optical signal between two output ports - the designated port and the surplus port. The use of a reflective Digital Spatial Light Modulator (DSLM) such as the DMD provides a motion-free digital control of the split ratio between the two output ports. Although the digital step between two possible successive split ratios can be fairly minimal with the use of a high resolution DMD but it is a challenge to correctly ascertain the exact image pattern on the DMD to obtain any desired specific split ratio. To counter this challenge, we propose the synchronized use of a circular pattern on the DMD, which serves as a circular clear aperture with a tunable radius, and an ECTL. The radius of the circular pattern on the DMD provides a digital control of the split ratio between the two ports whereas the ECTL, depending on its controller, can provide either an analog or a digital control by altering the beam radius which is incident at the DMD circular pattern. The radius of the circular pattern on the DMD can be minimally changed by one micro-pixel thickness. Setting the radius of the circular pattern on the DMD to an appropriate value provides the closest "ball-park" split ratio whereas further tuning the ECTL aids in slightly altering from this digitally set value to obtain the exact desired split ratio in-between any two digitally-set successive split ratios that correspond to any clear aperture radius of the DMD pattern and its incremental minimal

  15. Micro generation of electricity with gasification gas in a engine generator in dual mode; Microgeracao de eletricidade com gas de gaseificacao num motor gerador dual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Marcelo Jose da; Souza, Samuel Nelson Melegari de; Souza, Abel Alves de; Ricieri, Reinaldo P. [Universidade Estadual do Oeste do Parana (UNIOESTE), Cascavel, PE (Brazil)], E-mail: marcelo_js07@hotmail.com

    2010-07-01

    Among the alternatives to the increase of world energy demand the use of biomass as energy source is one of the most promising as it contributes to reducing emissions of carbon dioxide in the atmosphere. Gasification is a process technology of biomass energy in a gaseous biofuel. The fuel gas got a low calorific value that can be used in diesel engine in dual mode for power generation in isolated communities. This study aimed to evaluate the reduction in the consumption of oil diesel an engine generator, using gas from gasification of wood. The engine generator brand used, it was a BRANCO, with direct injection power of 10 hp and mated to an electric generator 5,5 kW. The fuel gas was produced in a gasifier type co-current. The engine generator was put on load system from 0.5 kW to 3.5 kW through electric bank of heaters. For the oil diesel savings, the gas was injected mixed with intake air, as the oil diesel was normally injected by the injector of the engine (motor dual). The consumption od diesel was measured diesel by means of a precision scale. It was concluded that the engine converted to dual mode when using the gas for the gasification of wood showed a decrease in diesel consumption by up to 57%. (author)

  16. A Plasma Based OES-CRDS Dual-mode Portable Spectrometer for Trace Element Detection: Emission and Ringdown Measurements of Mercury

    Science.gov (United States)

    Sahay, Peeyush; Scherrer, Susan; Wang, Chuji

    2012-10-01

    Design and development of a plasma based optical emission spectroscopy-cavity ringdown spectroscopy (OES-CRDS) dual-mode portable spectrometer for in situ monitoring of trace elements is described. A microwave plasma torch (MPT) has been utilized, which serves both as an atomization and excitation source for the two modes, viz. OES and CRDS, of the spectrometer. Operation of both modes of the instrument is demonstrated with initial measurements of elemental mercury (Hg). A detection limit of 44 ng mL-1 for Hg at 253.65 nm was determined with the emission mode of the instrument. Severe radiation trapping of 253.65 nm line hampers the measurement of Hg in higher concentration region (> 50 μg ml-1). Therefore, a different wavelength, 365.01 nm, is suggested to measure Hg in that region. Ringdown measurements of the metastable 6s6p ^3P0 state of Hg in the plasma using a 404.65 nm palm size diode laser was conducted to demonstrate the CRDS mode of the instrument. Along with being portable, dual-mode, and self-calibrated, the instrument is capable of measuring a wide range of concentration ranging from sub ng mL-1 to several μg ml-1 for a number of elements.

  17. A Novel Triple-Mode Bandpass Filter Based on a Dual-Mode Defected Ground Structure Resonator and a Microstrip Resonator

    Directory of Open Access Journals (Sweden)

    Xuehui Guan

    2013-01-01

    Full Text Available A novel triple-mode bandpass filter (BPF using a dual-mode defected ground structure (DGS resonator and a microstrip resonator is proposed in this paper. The dual-mode characteristic is achieved by loading a defected T-shaped stub to a uniform impedance DGS resonator. A uniform impedance microstrip resonator is designed on the top layer of the DGS resonator and a compact bandpass filter with three resonant modes in the passband can be achieved. A coupling scheme for the structure is given and the coupling matrix is synthesized. Based on the structure, a triple-mode BPF with central frequency of 2.57 GHz and equal ripple bandwidth of 15% is designed for the Wireless Local Area Network. Three transmission zeros are achieved at 1.48 GHz, 2.17 GHz, and 4.18 GHz, respectively, which improve the stopband characteristics of the filter. The proposed filter is fabricated and measured. Good agreements between measured results and simulated results verify the proposed structure well.

  18. Separation and purification of epimedin A, B, C, and icariin from the medicinal herb Epimedium brevicornum maxim by dual-mode HSCCC.

    Science.gov (United States)

    Li, Hua-Bin; Chen, Feng

    2009-01-01

    Epimedium brevicornum Maxim is a famous medicinal herb which has been widely used for the treatment of impotence, infertility, osteoporosis, cardiovascular diseases, amnesia, and senile functional diseases. A dual-mode high-speed counter-current chromatographic method is developed for the separation and purification of four bioactive flavonoids from the medicinal herb Epimedium brevicornum Maxim. The crude flavonoids are obtained by extraction with ethyl acetate and ethanol from the dried aerial parts of Epimedium brevicornum Maxim under sonication. High-speed counter-current chromatography with a two-phase solvent system composed of n-butanol-ethyl acetate-water (3:7:10, v/v) is performed using a dual-mode method, which yields 3.2 mg of epimedin A at a purity of 98.2%, 5.5 mg of epimedin B at a purity of 92.6%, 12.7 mg of epimedin C at a purity of 90.4%, and 42.9 mg of icariin at a purity of 96.8% based on the HPLC analysis. The recoveries are 95.2%, 89.4%, 91.1%, and 94.8%, respectively. The isolation of these flavonoids in adequate amounts makes them readily available for structure-activity relationship studies and for quality control of the herbal medicine.

  19. Advanced 3-D Ultrasound Imaging: 3-D Synthetic Aperture Imaging using Fully Addressed and Row-Column Addressed 2-D Transducer Arrays

    DEFF Research Database (Denmark)

    Bouzari, Hamed

    the important diagnostic information in a noninvasive manner. Diagnostic and therapeutic decisions often require accurate estimates of e.g., organ, cyst, or tumor volumes. 3-D ultrasound imaging can provide these measurements without relying on the geometrical assumptions and operator-dependent skills involved......Compared with conventional 2-D ultrasound imaging, real-time 3-D (or 4-D) ultrasound imaging has several advantages, resulting in a significant progress in the ultrasound imaging instrumentation over the past decade. Viewing the patient’s anatomy as a volume helps physicians to comprehend...... in such estimations using 2-D scans. Although the detail resolution of ultrasound can not compete with 3-D imaging modalities such as CT and MRI, the combination of patient safety by using nonionizing radiation, cost-effectiveness, portability, and real-time imaging ability makes ultrasound the preferred choice...

  20. A single-chip 32-channel analog beamformer with 4-ns delay resolution and 768-ns maximum delay range for ultrasound medical imaging with a linear array transducer.

    Science.gov (United States)

    Um, Ji-Yong; Kim, Yoon-Jee; Cho, Seong-Eun; Chae, Min-Kyun; Kim, Byungsub; Sim, Jae-Yoon; Park, Hong-June

    2015-02-01

    A single-chip 32-channel analog beamformer is proposed. It achieves a delay resolution of 4 ns and a maximum delay range of 768 ns. It has a focal-point based architecture, which consists of 7 sub-analog beamformers (sub-ABF). Each sub-ABF performs a RX focusing operation for a single focal point. Seven sub-ABFs perform a time-interleaving operation to achieve the maximum delay range of 768 ns. Phase interpolators are used in sub-ABFs to generate sampling clocks with the delay resolution of 4 ns from a low frequency system clock of 5 MHz. Each sub-ABF samples 32 echo signals at different times into sampling capacitors, which work as analog memory cells. The sampled 32 echo signals of each sub-ABF are originated from one target focal point at one instance. They are summed at one instance in a sub-ABF to perform the RX focusing for the target focal point. The proposed ABF chip has been fabricated in a 0.13- μ m CMOS process with an active area of 16 mm (2). The total power consumption is 287 mW. In measurement, the digital echo signals from a commercial ultrasound medical imaging machine were applied to the fabricated chip through commercial DAC chips. Due to the speed limitation of the DAC chips, the delay resolution was relaxed to 10 ns for the real-time measurement. A linear array transducer with no steering operation is used in this work.

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  2. Analytical prediction and experimental verification of performance at various operating conditions of a dual-mode traveling wave tube with multistage depressed collectors

    Science.gov (United States)

    Dayton, J. A., Jr.; Kosmahl, H. G.; Ramins, P.; Stankiewicz, N.

    1981-01-01

    A comparison of analytical and experimental results is presented for a high performance dual-mode traveling wave tube (TWT) operated over a wide range conditions. The computations are carried out with advanced multidimensional computer programs. These programs model the electron beam as a series of disks or rings of charge and follow their trajectories from the rf input of the TWT through the slow-wave structure refocusing system to their points of impacts in the depressed collector. TWT performance, collector efficiency, and collector current distribution are computed and compared with measurements. Very good agreement was obtained between computed and measured TWT performance and collector efficiencies, and the computer design of a highly efficient collector was demonstrated.

  3. Realization of Current Mode Universal Filter and a Dual-Mode Single Resistance Controlled Quadrature Oscillator Employing VDCC and Only Grounded Passive Elements

    Directory of Open Access Journals (Sweden)

    Manish Gupta

    2017-01-01

    Full Text Available The manuscript presents a circuit that can act as a universal filter as well as a single resistence controlled oscillator by unpretentiously changing the switch positions. The circuit employs only two active devices and all grounded passive elements. The utilization of only grounded passive components makes this circuit a better choice for integrated circuit implementation. The current mode biquadratic filter offers all the five basic responses along with independent tunability of its quality factor. The dual-mode quadrature sinusoidal oscillator offers explicit current outputs along with voltage outputs. The circuit also offers a simple and uncoupled condition of oscillation and frequency of oscillation. The typical analysis such as non-ideal, sensitivity and parasitic analysis along with the regular simulation results as well as experimental results are exposed here, to strengthen the design idea.

  4. Displaced dual-mode imaging with desorption electrospray ionization for simultaneous mass spectrometry imaging in both polarities and with several scan modes

    DEFF Research Database (Denmark)

    Janfelt, Christian; Wellner, Niels; Hansen, Harald S

    2013-01-01

    Displaced dual-mode imaging (DDI) is introduced as a method for simultaneous imaging in positive and negative-ion mode on the same sample with desorption electrospray ionization imaging, as well as a method for simultaneous imaging in full-scan and tandem mass spectrometry (MS/MS) mode. DDI...... only. Simultaneous full-scan and MS/MS imaging was demonstrated on the same mouse kidney, as the mouse had been given a relatively low dose of the antidepressive drug amitriptyline. While the full-scan data allowed imaging of the endogenous phospholipids, the drug and its metabolites were only visible...... in the MS/MS images. The latter approach is useful, for example in whole-body imaging experiments where the full-scan data gives an overview of the tissue, and the MS/MS mode provides the sensitivity to image trace amounts of drugs and metabolites. Copyright © 2013 John Wiley & Sons, Ltd....

  5. Obstetrical Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures of ... What are the limitations of Obstetrical Ultrasound Imaging? Obstetric ultrasound cannot identify all fetal abnormalities. Consequently, when ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  10. Liquid-phase sample preparation method for real-time monitoring of airborne asbestos fibers by dual-mode high-throughput microscopy.

    Science.gov (United States)

    Cho, Myoung-Ock; Kim, Jung Kyung; Han, Hwataik; Lee, Jeonghoon

    2013-01-01

    Asbestos that had been used widely as a construction material is a first-level carcinogen recognized by the World Health Organization. It can be accumulated in body by inhalation causing virulent respiratory diseases including lung cancer. In our previous study, we developed a high-throughput microscopy (HTM) system that can minimize human intervention accompanied by the conventional phase contrast microscopy (PCM) through automated counting of fibrous materials and thus significantly reduce analysis time and labor. Also, we attempted selective detection of chrysotile using DksA protein extracted from Escherichia coli through a recombinant protein production technique, and developed a dual-mode HTM (DM-HTM) by upgrading the HTM device. We demonstrated that fluorescently-labeled chrysotile asbestos fibers can be identified and enumerated automatically among other types of asbestos fibers or non-asbestos particles in a high-throughput manner through a newly modified HTM system for both reflection and fluorescence imaging. However there is a limitation to apply DM-HTM to airborne sample with current air collecting method due to the difficulty of applying the protein to dried asbestos sample. Here, we developed a technique for preparing liquid-phase asbestos sample using an impinger normally used to collect odor molecules in the air. It would be possible to improve the feasibility of the dual-mode HTM by integrating a sample preparation unit for making collected asbestos sample dispersed in a solution. The new technique developed for highly sensitive and automated asbestos detection can be a potential alternative to the conventional manual counting method, and it may be applied on site as a fast and reliable environmental monitoring tool.

  11. Hyaluronic acid-modified manganese-chelated dendrimer-entrapped gold nanoparticles for the targeted CT/MR dual-mode imaging of hepatocellular carcinoma

    Science.gov (United States)

    Wang, Ruizhi; Luo, Yu; Yang, Shuohui; Lin, Jiang; Gao, Dongmei; Zhao, Yan; Liu, Jinguo; Shi, Xiangyang; Wang, Xiaolin

    2016-09-01

    Hepatocellular carcinoma (HCC) is the most common malignant tumor of the liver. The early and effective diagnosis has always been desired. Herein, we present the preparation and characterization of hyaluronic acid (HA)-modified, multifunctional nanoparticles (NPs) targeting CD44 receptor-expressing cancer cells for computed tomography (CT)/magnetic resonance (MR) dual-mode imaging. We first modified amine-terminated generation 5 poly(amidoamine) dendrimers (G5.NH2) with an Mn chelator, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), fluorescein isothiocyanate (FI), and HA. Then, gold nanoparticles (AuNPs) were entrapped within the above raw product, denoted as G5.NH2-FI-DOTA-HA. The designed multifunctional NPs were formed after further Mn chelation and purification and were denoted as {(Au0)100G5.NH2-FI-DOTA(Mn)-HA}. These NPs were characterized via several different techniques. We found that the {(Au0)100G5.NH2-FI-DOTA(Mn)-HA} NPs exhibited good water dispersibility, stability under different conditions, and cytocompatibility within a given concentration range. Because both AuNPs and Mn were present in the product, {(Au0)100G5.NH2-FI-DOTA(Mn)-HA} displayed a high X-ray attenuation intensity and favorable r1 relaxivity, which are advantageous properties for targeted CT/MR dual-mode imaging. This approach was used to image HCC cells in vitro and orthotopically transplanted HCC tumors in a unique in vivo model through the CD44 receptor-mediated endocytosis pathway. This work introduces a novel strategy for preparing multifunctional NPs via dendrimer nanotechnology.

  12. Computer code and users' guide for the preliminary analysis of dual-mode space nuclear fission solid core power and propulsion systems, NUROC3A. AMS report No. 1239b

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, R.A.; Smith, W.W.

    1976-06-30

    The three-volume report describes a dual-mode nuclear space power and propulsion system concept that employs an advanced solid-core nuclear fission reactor coupled via heat pipes to one of several electric power conversion systems. The second volume describes the computer code and users' guide for the preliminary analysis of the system.

  13. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  14. A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: Initial test with elemental Hg

    Science.gov (United States)

    Sahay, Peeyush; Scherrer, Susan T.; Wang, Chuji

    2012-09-01

    A portable optical emission spectroscopy-cavity ringdown spectroscopy (OES-CRDS) dual-mode plasma spectrometer is described. A compact, low-power, atmospheric argon microwave plasma torch (MPT) is utilized as the emission source when the spectrometer is operating in the OES mode. The same MPT serves as the atomization source for ringdown measurements in the CRDS mode. Initial demonstration of the instrument is carried out by observing OES of multiple elements including mercury (Hg) in the OES mode and by measuring absolute concentrations of Hg in the metastable state 6s6p 3P0 in the CRDS mode, in which a palm-size diode laser operating at a single wavelength 405 nm is incorporated in the spectrometer as the light source. In the OES mode, the detection limit for Hg is determined to be 44 parts per 109 (ppb). A strong radiation trapping effect on emission measurements of Hg at 254 nm is observed when the Hg solution concentration is higher than 50 parts per 106 (ppm). The radiation trapping effect suggests that two different transition lines of Hg at 253.65 nm and 365.01 nm be selected for emission measurements in lower (50 ppm), respectively. In the CRDS mode, the detection limit of Hg in the metastable state 6s6p 3P0 is achieved to be 2.24 parts per 1012 (ppt) when the plasma is operating at 150 W with sample gas flow rate of 480 mL min-1; the detection limit corresponds to 50 ppm in Hg sample solution. Advantage of this novel spectrometer has two-fold, it has a large measurement dynamic range, from a few ppt to hundreds ppm and the CRDS mode can serve as calibration for the OES mode as well as high sensitivity measurements. Measurements of seven other elements, As, Cd, Mn, Ni, P, Pb, and Sr, using the OES mode are also carried out with detection limits of 1100, 33, 30, 144, 576, 94, and 2 ppb, respectively. Matrix effect in the presence of other elements on Hg measurements has been found to increase the detection limit to 131 ppb. These elements in lower

  15. Enhanced photoelectric conversion efficiency of dye-sensitized solar cells by the incorporation of dual-mode luminescent NaYF4:Yb3+/Er3+.

    Science.gov (United States)

    Li, Ying; Pan, Kai; Wang, Guofeng; Jiang, Baojiang; Tian, Chungui; Zhou, Wei; Qu, Yang; Liu, Shuai; Feng, Li; Fu, Honggang

    2013-06-14

    This work focuses on the design of composite photoanodes with dual-mode luminescent function as well as the effects of luminescent phosphors on the photoelectric properties of dye-sensitized solar cells. Specifically, hexagonal phase NaYF4:Yb(3+)/Er(3+) microcrystals were prepared by a hydrothermal method and added to the TiO2 photoanodes of dye-sensitized solar cells. The results indicated that the TiO2-NaYF4:Yb(3+)/Er(3+) composite photoanodes can emit visible light under 495 or 980 nm excitation, and then the visible light can be absorbed by dye N719 to improve light harvesting and thereby the efficiency of the solar cell. Under simulated solar radiation in the wavelength range of λ≥ 400 nm, the photoelectric conversion efficiency of TiO2-NaYF4:Yb(3+)/Er(3+) cell was increased by 10% compared to pure TiO2 cell. For the electrodes with the same thickness, the amount of dye adsorption of the photoanodes decreased a little after adding NaYF4:Yb(3+)/Er(3+), which was attributed to the decrease of TiO2 in the photoanodes. The electron transport and interfacial recombination kinetics were investigated by the electrochemical impedance spectroscopy and intensity-modulated photocurrent/photovoltage spectroscopy. The TiO2-NaYF4:Yb(3+)/Er(3+) cell has longer electron recombination time as well as electron transport time than pure TiO2 cell. The charge collection efficiency of TiO2-NaYF4:Yb(3+)/Er(3+) cell was little lower than that of pure TiO2 cell. In addition, the interfacial resistance of the TiO2-dye|I3(-)/I(-) electrolyte interface of TiO2-NaYF4:Yb(3+)/Er(3+) cell was much bigger than that of pure TiO2 cell. All these results indicated that the charge transport cannot be improved by adding NaYF4:Yb(3+)/Er(3+). And thus, the enhanced photoelectric conversion efficiencies of TiO2-NaYF4:Yb(3+)/Er(3+) cells were closely related to the dual-mode luminescent function of NaYF4:Yb(3+)/Er(3+).

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound is most often performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams ... to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . Ultrasound ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... What are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? In ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... What are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is ... in front of the rectum. top of page What are some common uses of the procedure? A ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  5. Characterization of Monomeric MnII/III/IV–Hydroxo Complexes from X- and Q-Band Dual Mode Electron Paramagnetic Resonance (EPR) Spectroscopy

    Science.gov (United States)

    Gupta, Rupal; Taguchi, Taketo; Borovik, A. S.; Hendrich, Michael P.

    2013-01-01

    Manganese–hydroxo species have been implicated in C–H bond activation performed by metalloenzymes, but the electronic properties of many of these intermediates are not well characterized. The present work presents a detailed characterization of three Mnn–OH complexes (where n = II, III, and IV) of the tris[(N′-tert-butylureaylato)-N-ethylene]aminato ([H3buea]3−) ligand using X- and Q-band dual mode electron paramagnetic resonance (EPR). Quantitative simulations for the [MnIIH3buea(OH)]2− complex demonstrated the ability to characterize similar MnII species commonly present in the resting states of manganese-containing enzymes. The spin states of the MnIII and MnIV complexes determined from EPR spectroscopy are S = 2 and 3/2, respectively, as expected for the C3 symmetry imposed by the [H3buea]3− ligand. Simulations of the spectra indicated the constant presence of two MnIV species in solutions of [MnIVH3buea(OH)] complex. The simulations of perpendicular- and parallel-mode EPR spectra allow determination of zero-field splitting and hyperfine parameters for all complexes. For the MnIII and MnIV complexes, density functional theory calculations are used to determine the isotropic Mn hyperfine values, to compare the excited electronic state energies, and to give theoretical estimates of the zero-field energy. PMID:24156406

  6. Characterization of monomeric Mn(II/III/IV)-hydroxo complexes from X- and Q-band dual mode electron paramagnetic resonance (EPR) spectroscopy.

    Science.gov (United States)

    Gupta, Rupal; Taguchi, Taketo; Borovik, A S; Hendrich, Michael P

    2013-11-04

    Manganese-hydroxo species have been implicated in C-H bond activation performed by metalloenzymes, but the electronic properties of many of these intermediates are not well characterized. The present work presents a detailed characterization of three Mn(n)-OH complexes (where n = II, III, and IV) of the tris[(N'-tert-butylureaylato)-N-ethylene]aminato ([H3buea](3-)) ligand using X- and Q-band dual mode electron paramagnetic resonance (EPR). Quantitative simulations for the [Mn(II)H3buea(OH)](2-) complex demonstrated the ability to characterize similar Mn(II) species commonly present in the resting states of manganese-containing enzymes. The spin states of the Mn(III) and Mn(IV) complexes determined from EPR spectroscopy are S = 2 and 3/2, respectively, as expected for the C3 symmetry imposed by the [H3buea](3-) ligand. Simulations of the spectra indicated the constant presence of two Mn(IV) species in solutions of [Mn(IV)H3buea(OH)] complex. The simulations of perpendicular- and parallel-mode EPR spectra allow determination of zero-field splitting and hyperfine parameters for all complexes. For the Mn(III) and Mn(IV) complexes, density functional theory calculations are used to determine the isotropic Mn hyperfine values, to compare the excited electronic state energies, and to give theoretical estimates of the zero-field energy.

  7. Extending the Constant Power Speed Range of the Brushless DC Motor through Dual Mode Inverter Control -- Part I: Theory and Simulation

    International Nuclear Information System (INIS)

    Lawler, J.S.

    2001-01-01

    An inverter topology and control scheme has been developed that can drive low-inductance, surface-mounted permanent magnet motors over the wide constant power speed range required in electric vehicle applications. This new controller is called the dual-mode inverter control (DMIC)[1]. The DMIC can drive either the Permanent Magnet Synchronous Machine (PMSM) with sinusoidal back emf, or the brushless dc machine (BDCM) with trapezoidal emf in the motoring and regenerative braking modes. In this paper we concentrate on the BDCM under high-speed motoring conditions. Simulation results show that if all motor and inverter loss mechanisms are neglected, the constant power speed range of the DMIC is infinite. The simulation results are supported by closed form expressions for peak and rms motor current and average power derived from analytical solution to the differential equations governing the DMIC/BDCM drive for the lossless case. The analytical solution shows that the range of motor inductance that can be accommodated by the DMIC is more than an order of magnitude such that the DMIC is compatible with both low- and high-inductance BDCMs. Finally, method is given for integrating the classical hysteresis band current control, used for motor control below base speed, with the phase advance of DMIC that is applied above base speed. The power versus speed performance of the DMIC is then simulated across the entire speed range

  8. Direct quantitative screening of influenza A virus without DNA amplification by single-particle dual-mode total internal reflection scattering.

    Science.gov (United States)

    Lee, Seungah; Chakkarapani, Suresh Kumar; Yeung, Edward S; Kang, Seong Ho

    2017-01-15

    Quantitative screening of influenza A (H7N9) virus without DNA amplification was performed based on single-particle dual-mode total internal reflection scattering (SD-TIRS) with a transmission grating (TG). A gold nanopad was utilized as a substrate for the hybridization of probe DNA molecules with the TIRS nanotag (silver-nanoparticle). The TG effectively isolated the scattering signals in first-order spectral images (n=+1) of the nanotag from that of the substrate, providing excellent enhancement of signal-to-noise and selectivity. By using single-DNA molecule/TIRS nanotag hybridization, target DNA molecules of H7N9 were detected down to 74 zM, which is at least 100,000 times lower than the current detection limit of 9.4fM. By simply modifying the design of the probe DNA molecules, this technique can be used to directly screen other viral DNAs in various human biological samples at the single-molecule level without target amplification. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Effect of mitochondrially targeted carboxy proxyl nitroxide on Akt-mediated survival in Daudi cells: Significance of a dual mode of action.

    Directory of Open Access Journals (Sweden)

    Gokul Variar

    Full Text Available Vicious cycles of mutations and reactive oxygen species (ROS generation contribute to cancer progression. The use of antioxidants to inhibit ROS generation promotes cytostasis by affecting the mutation cycle and ROS-dependent survival signaling. However, cancer cells select mutations to elevate ROS albeit maintaining mitochondrial hyperpolarization (Δψm, even under hypoxia. From this perspective, the use of drugs that disrupt both ROS generation and Δψm is a viable anticancer strategy. Hence, we studied the effects of mitochondrially targeted carboxy proxyl nitroxide (Mito-CP and a control ten carbon TPP moiety (Dec-TPP+ in the human Burkitt lymphoma cell line (Daudi and normal peripheral blood mononuclear cells under hypoxia and normoxia. We found preferential localization, Δψm and adenosine triphosphate loss, and significant cytotoxicity by Mito-CP in Daudi cells alone. Interestingly, ROS levels were decreased and maintained in hypoxic and normoxic cancer cells, respectively, by Mito-CP but not Dec-TPP+, therefore preventing any adaptive signaling. Moreover, dual effects on mitochondrial bioenergetics and ROS by Mito-CP curtailed the cancer survival via Akt inhibition, AMPK-HIF-1α activation and promoted apoptosis via increased BCL2-associated X protein and poly (ADP-ribose polymerase expression. This dual mode of action by Mito-CP provides a better explanation of the application of antioxidants with specific relevance to cancerous transformation and adaptations in the Daudi cell line.

  10. A Tactile Sensor for Ultrasound Imaging Systems.

    Science.gov (United States)

    Peng, Yiyan; Shkel, Yuri M; Hall, Timothy J

    2016-02-15

    Medical ultrasound systems are capable of monitoring a variety of health conditions while avoiding invasive procedures. However this function is complicated by ultrasound contrast of the tissue varying with contact pressure exerted by the probe. The knowledge of the contact pressure is beneficial for a variety of screening and diagnostic procedures involving ultrasound. This paper introduces a solid-state sensor array which measures the contact pressure distribution between the probe and the tissue marginally affecting the ultrasound imaging capabilities. The probe design utilizes the dielectrostriction mechanism which relates the change in dielectric properties of the sensing layer to deformation. The concept, structure, fabrication, and performance of this sensor array are discussed. The prototype device is highly tolerant to overloads (>1 MPa tested) and provides stress measurements in the range of 0.14 to 10 kPa. Its loss of ultrasound transmissivity is less 3dB at 9 MHz ultrasound frequency. This performance is satisfactory for clinical and biomedical research in ultrasound image formation and interpretation, however for commercial product, a higher ultrasound transmissivity is desired. Directions for improving the sensor ultrasound transparency and electrical performance are discussed. The sensor array described in this paper has been developed specifically for ultrasound diagnosis during breast cancer screening. However, the same sensing mechanism, similar configuration and sensor array structure can be applied to other applications involving ultrasound tools for medical diagnostics.

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary bladder ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  15. DUAL-MODE PROPULSION SYSTEM ENABLING CUBESAT EXPLORATION OF THE SOLAR SYSTEM NASA Innovative Advanced Concepts (NIAC) Phase I Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Nathan Jerred; Troy Howe; Adarsh Rajguru; Dr. Steven Howe

    2014-06-01

    It is apparent the cost of planetary exploration is rising as mission budgets declining. Currently small scientific beds geared to performing limited tasks are being developed and launched into low earth orbit (LEO) in the form of small-scale satellite units, i.e., CubeSats. These micro- and nano-satellites are gaining popularity among the university and science communities due to their relatively low cost and design flexibility. To date these small units have been limited to performing tasks in LEO utilizing solar-based power. If a reasonable propulsion system could be developed, these CubeSat platforms could perform exploration of various extra-terrestrial bodies within the solar system engaging a broader range of researchers. Additionally, being mindful of mass, smaller cheaper launch vehicles (~1,000 kgs to LEO) can be targeted. This, in effect, allows for beneficial explora-tion to be conducted within limited budgets. Researchers at the Center for Space Nuclear Re-search (CSNR) are proposing a low mass, radioisotope-based, dual-mode propulsion system capable of extending the exploration realm of these CubeSats out of LEO. The proposed radioisotope-based system would leverage the high specific energies [J/kg] associated with radioisotope materials and enhance their inherent low specific powers [W/g]. This is accomplished by accumulating thermal energy from nuclear decay within a central core over time. This allows for significant amounts of power to be transferred to a flowing gas over short periods of time. In the proposed configuration the stored energy can be utilized in two ways: (1) with direct propellant injection to the core, the energy can be converted into thrust through the use of a converging-diverging nozzle and (2) by flowing a working fluid through the core and subsequent Brayton engine, energy within the core can be converted to electrical energy. The first scenario achieves moderate ranges of thrust, but at a higher Isp than traditional chemical

  16. Predicting Vaccination Intention and Benefit and Risk Perceptions: The Incorporation of Affect, Trust, and Television Influence in a Dual-Mode Model.

    Science.gov (United States)

    Chen, Nien-Tsu Nancy

    2015-07-01

    Major health behavior change models tend to consider health decisions as primarily resulting from a systematic appraisal of relevant beliefs, such as the perceived benefits and risks of a pharmacological intervention. Drawing on research from the disciplines of risk management, communication, and psychology, this study proposed the inclusion of a heuristic route in established theory and tested the direction of influence between heuristic and systematic process variables. Affect and social trust were included as key heuristics in the proposed dual-mode framework of health decision making. Furthermore, exposure to health-related coverage on television was considered potentially influential over both heuristic and systematic process variables. To test this framework, data were collected from a national probability sample of 584 adults in the United States in 2012 regarding their decision to vaccinate against a hypothetical avian flu. The results provided some support for the bidirectional influence between heuristic and systematic processing. Affect toward flu vaccination and trust in the Food and Drug Administration were found to be powerful predictors of vaccination intention, enhancing intention both directly and indirectly via certain systematic process variables. The direction of influence between perceived susceptibility and severity, on the one hand, and affect, on the other, is less clear, suggesting the need for further research. Contrary to the opinion of media critics, exposure to televised health coverage was negatively associated with the perceived risks of vaccination. Results from this study carry theoretical and practical implications, and applying this model to the acceptance of different health interventions constitutes an area for future inquiries. © 2015 Society for Risk Analysis.

  17. Fluorescence quenching-based signal amplification on immunochromatography test strips for dual-mode sensing of two biomarkers of breast cancer.

    Science.gov (United States)

    Zhang, Bo; Ma, Wenjuan; Li, Fuxin; Gao, Weichen; Zhao, Qian; Peng, Weipan; Piao, Jiafang; Wu, Xiaoli; Wang, Hanjie; Gong, Xiaoqun; Chang, Jin

    2017-12-07

    Recently, immunochromatography test strips (ICTS) have been fully developed for point-of-care testing (POCT). However, the intrinsic limitations including non-quantitative detection of colloidal gold ICTS and low sensitivity of fluorescence ICTS (FICTS) significantly restrict their further application in clinical diagnosis. Taking advantages of rapid colorimetric qualitative detection and fluorescence quantitation, we designed a kind of sensitive and dual-mode magnetic FICTS (mFICTS) based on PLGA@Fe3O4 super-paramagnetic nanosphere (SPMN) probes quenching multiplex fluorescer on the test line through sandwich immunoreactions. Owing to the large number of Fe 3 O 4 nanoparticles (about 47) encapsulated in one SPMN, about 2680 Cy5 molecules were quenched by one SPMN on the test line such that to significantly improve the analytical sensitivity as well as the detection of whole blood samples via magnetic separation. Moreover, the aggregation of black SPMN on the test line enabled a quick naked-eye screening in 3 min. For high accuracy breast cancer diagnosis, combined determination of carcinoembryonic antigen (CEA) and carbohydrate antigen (CA153) was performed on one mFICTS with the limits of detection of about 0.06 ng mL -1 and 0.09 U mL -1 , respectively. Then, more than 50 clinical serum samples were investigated for high-resolution screening by mFICTS, and the results were coincident with those obtained by electrochemiluminescence immunoassay (ECLIA). Thus, the designed mFICTS is suitable for point-of-care diagnostics.

  18. Optimization of the composition of bimetallic core/shell Fe{sub 2}O{sub 3}/Au nanoparticles for MRI/CT dual-mode imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Song; Qi, Yueyong; Yang, Hua; Gong, Mingfu; Zhang, Dong; Zou, Liguang, E-mail: zlgxqyy@163.com [Third Military Medical University, Department of Radiology, Xinqiao Hospital (China)

    2013-11-15

    Bimetallic core/shell Fe{sub 2}O{sub 3}/Au nanoparticles are promising candidate dual-mode contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) imaging. However, the gold coating on the hybrid nanoparticles (hybrids) affects the MRI and CT imaging quality. A thick gold nanoshell increases the X-ray attenuation effect but decreases the magnetic saturation of the hybrids. Therefore, we studied the effect of the Fe{sub 2}O{sub 3} and Au composition on these properties to find a suitable hybrid for MRI and CT imaging. Water-soluble, Au-coated magnetic nanoparticles were synthesized by iteratively reducing Au{sup 3+} onto the Fe{sub 2}O{sub 3} surface via hydroxylamine seeding. The properties of the hybrids obtained after different numbers of Au seeding cycles were studied using transmission electron microscopy, UV–Vis spectrophotometry, a vibrating swatch gaussmeter, MRI, CT, and an MTT assay. The hybrids obtained after three Au seeding cycles had an Fe{sub 2}O{sub 3}:Au molar ratio of 7.2:26.8, a mean diameter of 48.3 nm, a UV–Vis absorbance peak of 550 nm, a saturation magnetization of 49.0 emu/g, and no cytotoxicity at a concentration of 500 μg/mL after incubation with RAW 264.7 cells for up to 72 h. The hybrids obtained after three Au seeding cycles are the preferred candidates for MRI and CT applications because of their relatively high R2 relaxivity (95 mM{sup −1 }s{sup −1}) and X-ray attenuation (1.87 times that of iodine) compared to those of the other hybrids investigated in this study.

  19. Optimization of the composition of bimetallic core/shell Fe2O3/Au nanoparticles for MRI/CT dual-mode imaging

    Science.gov (United States)

    Zhang, Song; Qi, Yueyong; Yang, Hua; Gong, Mingfu; Zhang, Dong; Zou, Liguang

    2013-11-01

    Bimetallic core/shell Fe2O3/Au nanoparticles are promising candidate dual-mode contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) imaging. However, the gold coating on the hybrid nanoparticles (hybrids) affects the MRI and CT imaging quality. A thick gold nanoshell increases the X-ray attenuation effect but decreases the magnetic saturation of the hybrids. Therefore, we studied the effect of the Fe2O3 and Au composition on these properties to find a suitable hybrid for MRI and CT imaging. Water-soluble, Au-coated magnetic nanoparticles were synthesized by iteratively reducing Au3+ onto the Fe2O3 surface via hydroxylamine seeding. The properties of the hybrids obtained after different numbers of Au seeding cycles were studied using transmission electron microscopy, UV-Vis spectrophotometry, a vibrating swatch gaussmeter, MRI, CT, and an MTT assay. The hybrids obtained after three Au seeding cycles had an Fe2O3:Au molar ratio of 7.2:26.8, a mean diameter of 48.3 nm, a UV-Vis absorbance peak of 550 nm, a saturation magnetization of 49.0 emu/g, and no cytotoxicity at a concentration of 500 μg/mL after incubation with RAW 264.7 cells for up to 72 h. The hybrids obtained after three Au seeding cycles are the preferred candidates for MRI and CT applications because of their relatively high R2 relaxivity (95 mM-1 s-1) and X-ray attenuation (1.87 times that of iodine) compared to those of the other hybrids investigated in this study.

  20. Optimization of the composition of bimetallic core/shell Fe2O3/Au nanoparticles for MRI/CT dual-mode imaging

    International Nuclear Information System (INIS)

    Zhang, Song; Qi, Yueyong; Yang, Hua; Gong, Mingfu; Zhang, Dong; Zou, Liguang

    2013-01-01

    Bimetallic core/shell Fe 2 O 3 /Au nanoparticles are promising candidate dual-mode contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) imaging. However, the gold coating on the hybrid nanoparticles (hybrids) affects the MRI and CT imaging quality. A thick gold nanoshell increases the X-ray attenuation effect but decreases the magnetic saturation of the hybrids. Therefore, we studied the effect of the Fe 2 O 3 and Au composition on these properties to find a suitable hybrid for MRI and CT imaging. Water-soluble, Au-coated magnetic nanoparticles were synthesized by iteratively reducing Au 3+ onto the Fe 2 O 3 surface via hydroxylamine seeding. The properties of the hybrids obtained after different numbers of Au seeding cycles were studied using transmission electron microscopy, UV–Vis spectrophotometry, a vibrating swatch gaussmeter, MRI, CT, and an MTT assay. The hybrids obtained after three Au seeding cycles had an Fe 2 O 3 :Au molar ratio of 7.2:26.8, a mean diameter of 48.3 nm, a UV–Vis absorbance peak of 550 nm, a saturation magnetization of 49.0 emu/g, and no cytotoxicity at a concentration of 500 μg/mL after incubation with RAW 264.7 cells for up to 72 h. The hybrids obtained after three Au seeding cycles are the preferred candidates for MRI and CT applications because of their relatively high R2 relaxivity (95 mM −1  s −1 ) and X-ray attenuation (1.87 times that of iodine) compared to those of the other hybrids investigated in this study

  1. Quantification of variable functional-group densities of mixed-silane monolayers on surfaces via a dual-mode fluorescence and XPS label.

    Science.gov (United States)

    Fischer, Tobias; Dietrich, Paul M; Streeck, Cornelia; Ray, Santanu; Nutsch, Andreas; Shard, Alex; Beckhoff, Burkhard; Unger, Wolfgang E S; Rurack, Knut

    2015-03-03

    The preparation of aminated monolayers with a controlled density of functional groups on silica surfaces through a simple vapor deposition process employing different ratios of two suitable monoalkoxysilanes, (3-aminopropyl)diisopropylethoxysilane (APDIPES) and (3-cyanopropyl)dimethylmethoxysilane (CPDMMS), and advances in the reliable quantification of such tailored surfaces are presented here. The one-step codeposition process was carried out with binary silane mixtures, rendering possible the control over a wide range of densities in a single step. In particular, APDIPES constitutes the functional silane and CPDMMS the inert component. The procedure requires only small amounts of silanes, several ratios can be produced in a single batch, the deposition can be carried out within a few hours and a dry atmosphere can easily be employed, limiting self-condensation of the silanes. Characterization of the ratio of silanes actually bound to the surface can then be performed in a facile manner through contact angle measurements using the Cassie equation. The reliable estimation of the number of surface functional groups was approached with a dual-mode BODIPY-type fluorescence label, which allows quantification by fluorescence and XPS on one and the same sample. We found that fluorescence and XPS signals correlate over at least 1 order of magnitude, allowing for a direct linking of quantitative fluorescence analysis to XPS quantification. Employment of synchrotron-based methods (XPS; reference-free total reflection X-ray fluorescence, TXRF) made the traceable quantification of surface functional groups possible, providing an absolute reference for quantitative fluorescence measurements through a traceable measurement chain.

  2. An assessment of the dual-mode reactivity controlled compression ignition/conventional diesel combustion capabilities in a EURO VI medium-duty diesel engine fueled with an intermediate ethanol-gasoline blend and biodiesel

    International Nuclear Information System (INIS)

    Benajes, Jesús; García, Antonio; Monsalve-Serrano, Javier; Balloul, Iyad; Pradel, Gérard

    2016-01-01

    Highlights: • Reactivity controlled compression ignition regime utilized from 25% to 35% load. • Dual-mode reduces the regeneration periods of the diesel particulate filter. • The use of near-term available biofuels allows good performance and emissions. • Dual-mode leads to 2% greater efficiency than diesel combustion at high engine speeds. - Abstract: This work investigates the capabilities of the dual-mode reactivity controlled compression ignition/conventional diesel combustion engine operation to cover the full operating range of a EURO VI medium-duty diesel engine with compression ratio of 17.5:1. This concept is based on covering all the engine map switching between the reactivity controlled compression ignition and the conventional diesel combustion operating modes. Specifically, the benefits of reactivity controlled compression ignition combustion are exploited whenever possible according to certain restrictions, while the conventional diesel combustion operation is used to cover the zones of the engine map in which the reactivity controlled compression ignition operation is limited. The experiments were conducted using a single-cylinder research diesel engine derived from the multi-cylinder production engine. In addition, considering the mandatory presence of biofuels in the future context of road transport and the ability of ethanol to be blended with gasoline, the low reactivity fuel used in the study is a blend of 20% ethanol by volume with 80% of 95 octane number gasoline. Moreover, a diesel containing 7% of biodiesel has been used as high reactivity fuel. Firstly, a reactivity controlled compression ignition mapping is performed to check the operational limits of the concept in this engine platform. Later, based on the results, the potential of the dual-mode concept is discussed. Results suggest that, under the constraints imposed, reactivity controlled compression ignition combustion can be utilized between 25% and 35% load. In this region

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams are also used to ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... as detailed as with the transrectal probe. An MRI of the pelvis may be obtained as an ... Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic pain abnormal ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... your knees toward your chest. To obtain high-quality images, an ultrasound transducer – a plastic cylinder about ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... right in front of the rectum. top of page What are some common uses of the procedure? A ... ultrasound to clean out the bowel. top of page What does the equipment look like? Ultrasound scanners consist ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... depth investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... obtain high-quality images, an ultrasound transducer – a plastic cylinder about the size of a finger – is ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... records tiny changes in the sound's pitch and direction. These signature waves are instantly measured and displayed ... ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of ... show up well on x-ray images. Ultrasound causes no health problems and may be repeated as ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Transvaginal ultrasound is performed very much like a gynecologic exam and involves the insertion of the transducer ... with your feet in stirrups similar to a gynecologic exam. Transrectal: For a transrectal ultrasound, a protective ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  19. Dual-Mode Combined Infra Red and Air-Coupled Ultrasonic Technique for Real-Time Industrial Process Control with Special Reference to the Food Industry

    Science.gov (United States)

    Pallav, P.; Hutchins, D. A.; Diamond, G. G.; Gan, T. H.; Hellyer, J. E.

    2008-02-01

    This paper describes the use of air-coupled ultrasound and Near Infra red (NIR) as complimentary techniques for food quality assessment. A major study has been performed, in collaboration with four industrial food companies, to investigate the use of air-coupled ultrasound and NIR to both detect foreign bodies, and to measure certain parameters of interest, such as the amount of a certain additive. The research has demonstrated that air-coupled ultrasound can be used in on-line situations, measuring food materials such as chocolate and cheese. It is also capable of performing measurements on moving sealed metal cans containing food, and is able to detect foreign bodies with the top removed, as encountered just before sealing. NIR has been used as a complimentary technique to test food materials where propagation of air-coupled ultrasound was found to be difficult. This could be due to the presence of air pockets within the food material, as in the case of bread dough.

  20. Ultrasound Imaging Techniques for Spatiotemporal Characterization of Composition, Microstructure, and Mechanical Properties in Tissue Engineering.

    Science.gov (United States)

    Deng, Cheri X; Hong, Xiaowei; Stegemann, Jan P

    2016-08-01

    Ultrasound techniques are increasingly being used to quantitatively characterize both native and engineered tissues. This review provides an overview and selected examples of the main techniques used in these applications. Grayscale imaging has been used to characterize extracellular matrix deposition, and quantitative ultrasound imaging based on the integrated backscatter coefficient has been applied to estimating cell concentrations and matrix morphology in tissue engineering. Spectral analysis has been employed to characterize the concentration and spatial distribution of mineral particles in a construct, as well as to monitor mineral deposition by cells over time. Ultrasound techniques have also been used to measure the mechanical properties of native and engineered tissues. Conventional ultrasound elasticity imaging and acoustic radiation force imaging have been applied to detect regions of altered stiffness within tissues. Sonorheometry and monitoring of steady-state excitation and recovery have been used to characterize viscoelastic properties of tissue using a single transducer to both deform and image the sample. Dual-mode ultrasound elastography uses separate ultrasound transducers to produce a more potent deformation force to microscale characterization of viscoelasticity of hydrogel constructs. These ultrasound-based techniques have high potential to impact the field of tissue engineering as they are further developed and their range of applications expands.

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. 3D ultrasound imaging : Fast and cost-effective morphometry of musculoskeletal tissue

    NARCIS (Netherlands)

    Weide, Guido; Van Der Zwaard, Stephan; Huijing, Peter A.; Jaspers, Richard T.; Harlaar, Jaap

    2017-01-01

    The developmental goal of 3D ultrasound imaging (3DUS) is to engineer a modality to perform 3D morphological ultrasound analysis of human muscles. 3DUS images are constructed from calibrated freehand 2D B-mode ultrasound images, which are positioned into a voxel array. Ultrasound (US) imaging allows

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  5. Efficient array design for sonotherapy

    International Nuclear Information System (INIS)

    Stephens, Douglas N; Kruse, Dustin E; Ferrara, Katherine W; Ergun, Arif S; Barnes, Stephen; Lu, X Ming

    2008-01-01

    New linear multi-row, multi-frequency arrays have been designed, constructed and tested as fully operational ultrasound probes to produce confocal imaging and therapeutic acoustic intensities with a standard commercial ultrasound imaging system. The triple-array probes and imaging system produce high quality B-mode images with a center row imaging array at 5.3 MHz and sufficient acoustic power with dual therapeutic arrays to produce mild hyperthermia at 1.54 MHz. The therapeutic array pair in the first probe design (termed G3) utilizes a high bandwidth and peak pressure, suitable for mechanical therapies. The second multi-array design (termed G4) has a redesigned therapeutic array pair which is optimized for a high time-averaged power output suitable for mild hyperthermia applications. The 'thermal therapy' design produces more than 4 W of acoustic power from the low-frequency arrays with only a 10.5 deg. C internal rise in temperature after 100 s of continuous use with an unmodified conventional imaging system or substantially longer operation at lower acoustic power. The low-frequency arrays in both probe designs were examined and contrasted for real power transfer efficiency with a KLM model which includes all lossy contributions in the power delivery path from system transmitters to the tissue load. Laboratory verification was successfully performed for the KLM-derived estimates of transducer parallel model acoustic resistance and dissipation resistance, which are the critical design factors for acoustic power output and undesired internal heating, respectively

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Prostate Ultrasound Imaging? Men who have ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  11. Ultrasound -- Vascular

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the ... is specialized and is best performed by a technologist and physician with experience in vascular ultrasound imaging. top of page Additional Information and Resources ...

  12. Ultrasound imaging

    International Nuclear Information System (INIS)

    Grant, E.G.; Doherty, F.J.

    1986-01-01

    Diagnostic ultrasound was used as early as 1950 in attempts to detect malignant tumors within the human breast and brain. In the years following, however, little attention was paid to this method of imaging by the radiologic community. Extensive work with this technique was not begun until the 1960s, when bistable ultrasound enabled sonographers to display organ outlines for the first time. Prior to the development of bistable ultrasound, sonographic images were limited to A-mode displays, which were merely a series of amplitude spikes on a graph. Over the past 20 or so years, major advances in ultrasound technology have gradually taken us from the simple graphic A-mode display, through bistable organ outlines, to gray-scale images with excellent parenchymal detail, and finally to real-time ultrasound

  13. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... waves from passing into the body. The sonographer (ultrasound technologist) or radiologist then gently presses the transducer against ... performed on an infant, a nurse or radiologic technologist may assist with keeping the ... procedure? Ultrasound examinations are painless and easily tolerated by most ...

  14. Trauma Ultrasound.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Prachanukool, Thidathit; Sricharoen, Pungkava; Saksobhavivat, Nitima; Kaewlai, Rathachai

    2015-10-01

    Ultrasound plays a pivotal role in the evaluation of acute trauma patients through the use of multi-site scanning encompassing abdominal, cardiothoracic, vascular and skeletal scans. In a high-speed polytrauma setting, because exsanguinations are the primary cause of trauma morbidity and mortality, ultrasound is used for quick and accurate detection of hemorrhages in the pericardial, pleural, and peritoneal cavities during the primary Advanced Trauma Life Support (ATLS) survey. Volume status can be assessed non-invasively with ultrasound of the inferior vena cava (IVC), which is a useful tool in the initial phase and follow-up evaluations. Pneumothorax can also be quickly detected with ultrasound. During the secondary survey and in patients sustaining low-speed or localized trauma, ultrasound can be used to help detect abdominal organ injuries. This is particularly helpful in patients in whom hemoperitoneum is not identified on an initial scan because findings of organ injuries will expedite the next test, often computed tomography (CT). Moreover, ultrasound can assist in detection of fractures easily obscured on radiography, such as rib and sternal fractures. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Synthesis of Ferromagnetic Fe0.6 Mn0.4 O Nanoflowers as a New Class of Magnetic Theranostic Platform for In Vivo T1 -T2 Dual-Mode Magnetic Resonance Imaging and Magnetic Hyperthermia Therapy.

    Science.gov (United States)

    Liu, Xiao Li; Ng, Cheng Teng; Chandrasekharan, Prashant; Yang, Hai Tao; Zhao, Ling Yun; Peng, Erwin; Lv, Yun Bo; Xiao, Wen; Fang, Jie; Yi, Jia Bao; Zhang, Huan; Chuang, Kai-Hsiang; Bay, Boon Huat; Ding, Jun; Fan, Hai Ming

    2016-08-01

    Uniform wüstite Fe0.6 Mn0.4 O nanoflowers have been successfully developed as an innovative theranostic agent with T1 -T2 dual-mode magnetic resonance imaging (MRI), for diagnostic applications and therapeutic interventions via magnetic hyperthermia. Unlike their antiferromagnetic bulk counterpart, the obtained Fe0.6 Mn0.4 O nanoflowers show unique room-temperature ferromagnetic behavior, probably due to the presence of an exchange coupling effect. Combined with the flower-like morphology, ferromagnetic Fe0.6 Mn0.4 O nanoflowers are demonstrated to possess dual-modal MRI sensitivity, with longitudinal relaxivity r1 and transverse relaxivity r2 as high as 4.9 and 61.2 mm(-1) s(-1) [Fe]+[Mn], respectively. Further in vivo MRI carried out on the mouse orthotopic glioma model revealed gliomas are clearly delineated in both T1 - and T2 -weighted MR images, after administration of the Fe0.6 Mn0.4 O nanoflowers. In addition, the Fe0.6 Mn0.4 O nanoflowers also exhibit excellent magnetic induction heating effects. Both in vitro and in vivo magnetic hyperthermia experimentation has demonstrated that magnetic hyperthermia by using the innovative Fe0.6 Mn0.4 O nanoflowers can induce MCF-7 breast cancer cell apoptosis and a complete tumor regression without appreciable side effects. The results have demonstrated that the innovative Fe0.6 Mn0.4 O nanoflowers can be a new magnetic theranostic platform for in vivo T1 -T2 dual-mode MRI and magnetic thermotherapy, thereby achieving a one-stop diagnosis cum effective therapeutic modality in cancer management. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. An amphipathic undecapeptide with all D-amino acids shows promising activity against colistin-resistant strains of Acinetobacter baumannii and a dual mode of action

    DEFF Research Database (Denmark)

    Oddo, Alberto; Thomsen, Thomas Thyge; Kjelstrup, Susanne

    2016-01-01

    Multiple strains of Acinetobacter baumannii have developed multidrug resistance (MDR), leaving colistin as the only effective treatment. The cecropin-α-melittin hybrid BP100 (KKLFKKILKYL-NH2) and its analogs have previously shown activity against a wide array of plant and human pathogens....... In this study, we investigated the in vitro antibacterial activities of 18 BP100 analogs (four known and 14 new) against the MDR A. baumannii strain ATCC BAA-1605, as well as against a number of other clinically relevant human pathogens. Selected peptides were further evaluated against strains of A. baumannii...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  19. Transvaginal ultrasound

    Science.gov (United States)

    ... bleeding and menstrual problems Certain types of infertility Ectopic pregnancy Pelvic pain Transvaginal ultrasound is also used during ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should be consulted for ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient consultation. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's ( ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is enlarged. Ultrasound ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test ... that allows the physician to see and evaluate blood flow through arteries and veins in the abdomen, ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... by a computer, which in turn creates a real-time picture on the monitor. One or more ...

  8. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be turned to either side to improve the quality of the images. After you are positioned on ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... than 20 minutes. top of page What will I experience during and after the procedure? Ultrasound exams in which the transducer is inserted into an opening of the body may produce minimal discomfort. If no biopsy is ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... called the Doppler effect). A computer collects and processes the sounds and creates graphs or color pictures ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a more in-depth investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... such as the liver or kidneys. top of page What are some common uses of the procedure? In ... ask for your child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image ... based on the same principles involved in the sonar used by bats, ships and fishermen. When a ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image ... based on the same principles involved in the sonar used by bats, ships and fishermen. When a ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... prior to the exam. Bringing books, small toys, music or games can help to distract the child ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. top ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... radiation. This procedure requires little to no special preparation. Leave jewelry at home and wear loose, comfortable ... biopsy is planned. An enema may be taken two to four hours before the ultrasound to clean ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound Imaging? Men who have had the tail end of their bowel (rectum) removed during prior surgery ... or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Please ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... These exams are frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and ... identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... the scanner by a cord. Some exams may use different transducers (with different capabilities) during a single ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams, you will be positioned lying face-up on an examination table that can be tilted ... you at the conclusion of your examination. Follow-up examinations may be necessary. Your doctor will explain ...

  19. Thyroid ultrasound

    Science.gov (United States)

    ... Thyroid physiology and diagnostic evaluation of patients with thyroid disorders. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; 2016:chap 11. ... Thyroid Tests Read more Ultrasound ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to investigate a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is ... a man's prostate gland and surrounding tissue. The exam typically requires insertion of an ultrasound probe into ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty ... vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... fluid). In medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, ... the sensitive receiver in the transducer records tiny changes in the sound's pitch and direction. These signature ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... fluid). In medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, ... the sensitive receiver in the transducer records tiny changes in the sound's pitch and direction. These signature ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is sometimes seen in infections top of page How should I prepare? You should wear comfortable, loose- ... sheath and lubricated before insertion. top of page How does the procedure work? Ultrasound imaging is based ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gland for later laboratory testing. top of page How should I prepare? You should wear comfortable, loose- ... and lubricated with a gel. top of page How does the procedure work? Ultrasound imaging is based ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to the child prior to the exam. Bringing books, small toys, music or games can help to ... the ultrasound signal to return from the area within the patient that is being examined to the ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... prior to the exam. Bringing books, small toys, music or games can help to distract the child ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... systems. Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. You may be asked to drink water prior to the examination to fill your bladder. ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any ... size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  6. Breast ultrasound

    Science.gov (United States)

    ... such as: Cysts, which are, fluid-filled sacs Fibroadenomas , which are, noncancerous solid growths Lipomas, which are, noncancerous fatty lumps that can occur anywhere in the body, including the breasts Breast cancers can also be seen with ultrasound. ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... abnormal area in the prostate gland for later laboratory testing. top of page How should I prepare? ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  13. Fundamentals of ultrasonic phased arrays

    CERN Document Server

    Schmerr, Lester W

    2014-01-01

    This book describes in detail the physical and mathematical foundations of ultrasonic phased array measurements.?The book uses linear systems theory to develop a comprehensive model of the signals and images that can be formed with phased arrays. Engineers working in the field of ultrasonic nondestructive evaluation (NDE) will find in this approach a wealth of information on how to design, optimize and interpret ultrasonic inspections with phased arrays. The fundamentals and models described in the book will also be of significant interest to other fields, including the medical ultrasound and

  14. Detecting tissue optical and mechanical properties with an ultrasound modulated optical imaging system in reflection detection geometry.

    Science.gov (United States)

    Cheng, Yi; Li, Sinan; Eckersley, Robert J; Elson, Daniel S; Tang, Meng-Xing

    2015-01-01

    Tissue optical and mechanical properties are correlated to tissue pathologic changes. This manuscript describes a dual-mode ultrasound modulated optical imaging system capable of sensing local optical and mechanical properties in reflection geometry. The optical characterisation was achieved by the acoustic radiation force assisted ultrasound modulated optical tomography (ARF-UOT) with laser speckle contrast detection. Shear waves generated by the ARF were also tracked optically by the same system and the shear wave speed was used for the elasticity measurement. Tissue mimicking phantoms with multiple inclusions buried at 11 mm depth were experimentally scanned with the dual-mode system. The inclusions, with higher optical absorption and/or higher stiffness than background, were identified based on the dual results and their stiffnesses were quantified. The system characterises both optical and mechanical properties of the inclusions compared with the ARF-UOT or the elasticity measurement alone. Moreover, by detecting the backward scattered light in reflection detection geometry, the system is more suitable for clinical applications compared with transmission geometry.

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  19. Magnetic arrays

    Science.gov (United States)

    Trumper, D.L.; Kim, W.; Williams, M.E.

    1997-05-20

    Electromagnet arrays are disclosed which can provide selected field patterns in either two or three dimensions, and in particular, which can provide single-sided field patterns in two or three dimensions. These features are achieved by providing arrays which have current densities that vary in the windings both parallel to the array and in the direction of array thickness. 12 figs.

  20. Magnetic arrays

    Energy Technology Data Exchange (ETDEWEB)

    Trumper, David L. (Plaistow, NH); Kim, Won-jong (Cambridge, MA); Williams, Mark E. (Pelham, NH)

    1997-05-20

    Electromagnet arrays which can provide selected field patterns in either two or three dimensions, and in particular, which can provide single-sided field patterns in two or three dimensions. These features are achieved by providing arrays which have current densities that vary in the windings both parallel to the array and in the direction of array thickness.

  1. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  2. Advanced ultrasound probes for medical imaging

    Science.gov (United States)

    Wildes, Douglas G.; Smith, L. Scott

    2012-05-01

    New medical ultrasound probe architectures and materials build upon established 1D phased array technology and provide improved imaging performance and clinical value. Technologies reviewed include 1.25D and 1.5D arrays for elevation slice thickness control; electro-mechanical and 2D array probes for real-time 3D imaging; catheter probes for imaging during minimally-invasive procedures; single-crystal piezoelectric materials for greater frequency bandwidth; and cMUT arrays using silicon MEMS in place of piezo materials.

  3. Volumetric Flow Measurement Using an Implantable CMUT Array.

    Science.gov (United States)

    Mengli Wang; Jingkuang Chen

    2011-06-01

    This paper describes volumetric-flow velocity measurement using an implantable capacitive micromachined ultrasonic transducer (CMUT) array. The array is comprised of multiple-concentric CMUT rings for ultrasound transmission and an outmost annular CMUT array for ultrasound reception. Microelectromechanical-system (MEMS) fabrication technology allows reception CMUT on this flowmeter to be implemented with a different membrane thickness and gap height than that of transmission CMUTs, optimizing the performance of these two different kinds of devices. The silicon substrate of this 2-mm-diameter CMUT ring array was bulk micromachined to approximately 80 to 100 μm thick, minimizing tissue disruption. The blood-flow velocity was detected using pulse ultrasound Doppler by comparing the demodulated echo ultrasound with the incident ultrasound. The demodulated ultrasound signal was sampled by a pulse delayed in time domain from the transmitted burst, which corresponds to detecting the signal at a specific distance. The flow tube/vessel diameter was detected through the time-flight delay difference from near and far wall reflections, which was measured from the ultrasound pulse echo. The angle between the ultrasound beam and the flow was found by using the cross-correlation from consecutive ultrasound echoes. Artificial blood flowing through three different polymer tubes was experimented with, while keeping the same volumetric flow rate. The discrepancy in flow measurement results between this CMUT meter and a calibrated laser Doppler flowmeter is less than 5%.

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special preparation. You may be asked to drink water prior to the examination to fill your bladder. Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and receive the returning sound waves), as well as the type of body ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and receive the returning sound waves), as well as the type of body ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the pelvis uses sound waves to produce pictures of the structures and organs in the lower abdomen and pelvis. There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... BPH) , with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Pelvic Ultrasound Imaging? ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Prostate Ultrasound Imaging? ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then listens for the returning echoes from ... ultrasound , there are no known harmful effects on humans. top ... waves as they pass deeper into the body and need to be returned to the transducer ...

  17. Hip Ultrasound

    Science.gov (United States)

    ... prior to the exam. Bringing books, small toys, music or games can help to distract the child and make the time ... back or side. Almost all of the ultrasound studies of infants and ... studied. The gel will help the transducer make secure contact with the body ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... No Please type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Please help us improve RadiologyInfo.org by taking our brief survey: Survey Do ... Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... 20 minutes. top of page What will I experience during and after the procedure? Ultrasound exams in ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in which needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as clots) narrowing of vessels tumors ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such as needle biopsies , in which a needle is used to sample cells (tissue) from an abnormal area in the ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... time. Follow-up examinations are sometimes the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. ... not show up well on x-ray images. Ultrasound causes no health problems and may ...

  4. Characterization of a novel Optical Micro-machined Ultrasound Transducer

    NARCIS (Netherlands)

    Leinders, S.M.

    2017-01-01

    We design and demonstrate a prototype ultrasound sensor based on a photonic micro-ring resonator integrated on a silicon membrane, and show that it can detect very low pressure ultrasound waves. The use of integrated photonics in future array transducers has several benefits: for instance it

  5. Sequential Growth of Uniform β-NaYF4@β-NaLnF4 (Ln = Y, Lu, Yb Microcrystals with Luminescent Properties of Multicolor Tuning and Dual-Mode Emission

    Directory of Open Access Journals (Sweden)

    Dandan Ju

    2017-12-01

    Full Text Available We synthesized the uniform core-shell microstructured compounds with hexagonal phase NaYF4:Er/Yb microrods as the core and hexagonal phase NaLnF4 (NaYbF4, NaLuF4:Yb/Tm, NaYF4:Yb/Er, NaYF4:Eu as the shell based on the hydrothermal reaction. These microscale core-shell structures provided a platform for the spatially confining optical process while possessing high luminescence efficiency. The thickness of the shell could be controlled by adjusting the amounts of shell precursor, which significantly affected the intensity of the shell dopant ions emission and the emission color of core-shell upconversion luminescence (UCL. The uniform NaYF4@NaLnF4 (Ln = Y, Lu, Yb microrods, with a series of rare-earth ions doped into the core and shell layer at various doping concentrations, achieved color-tuning of the upconversion (UC emission and dual-mode emission at the single-microcrystal level, thus allowing the efficient utilization of core-shell microcrystals in the photonics and security labeling. This study suggests a new class of luminescent materials in the microscopic field.

  6. One Clock-Cycle Response 0.5 m CMOS Dual-Mode ΣΔ DC-DC Bypass Boost Converter Stable over Wide ESRLC Variations

    Directory of Open Access Journals (Sweden)

    Neeraj A. Keskar

    2010-01-01

    Full Text Available Power supplies in portable applications must not only conform and adapt to their highly integrated on-chip and in-package environments but also, more intrinsically, respond quickly to fast load dumps to achieve and maintain high accuracy. The frequency-compensation network, however, limits speed and regulation performance because it must cater to all combinations of filter capacitor , inductor L, and 's equivalent series resistance ESR resulting from tolerance and modal design targets. As such, it must compensate the worst-case condition and therefore restrain the performance of all other possible scenarios, even if the likelihood of occurrence of the latter is considerably high and the former substantially low. Sigma-delta (ΣΔ control, which addresses this issue in buck converters by easing its compensation requirements and offering one-cycle transient response, has not been able to simultaneously achieve high bandwidth, high accuracy, and wide ESRLC compliance in boost converters. This paper presents a dual-mode ΣΔ boost bypass converter, which by using a high-bandwidth bypass path only during transient load-dump events was experimentally 1.41 to 6 times faster than the state of the art in current-mode ΣΔ boost supplies, and this without any compromise in ESRLC compliance range (0–50 mΩ, 1–30 H, and 1–350 F.

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... phased array) receiver coil. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos related to General Ultrasound Sponsored by ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study may be part ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is ... into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , ...

  15. Venous Ultrasound (Extremities)

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... ultrasound images are reviewed. This ultrasound examination is usually ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can only see ...

  17. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  18. Fabrication of Linear Array and Top-Orthogonal-to-Bottom Electrode CMUT Arrays With a Sacrificial Release Process.

    Science.gov (United States)

    Greenlay, Benjamin A; Zemp, Roger J

    2017-01-01

    The microfabrication processes for sacrificial-release-based capacitive micromachined ultrasound transducer arrays are provided with an emphasis on top-orthogonal-to-bottom electrode 2-D arrays. These arrays have significant promise for high-quality 3-D imaging with reduced wiring complexity compared with fully wired arrays. The protocols and best practices are outlined in significant detail along with design considerations and notes of caution for pitfalls and factors impacting yield.

  19. Fabrication of Linear Array and Top-Orthogonal-to-Bottom Electrode (TOBE) CMUT Arrays with a Sacrificial Release Process.

    Science.gov (United States)

    Greenlay, Benjamin; Zemp, Roger

    2016-10-24

    The microfabrication processes for sacrificial-release based capacitive micromachined ultrasound transducer (CMUT) arrays are provided with an emphasis on top-orthogonal-to-bottom electrode (TOBE) 2D arrays. These arrays have significant promise for high-quality 3D imaging with reduced wiring complexity compared to fully-wired arrays. The protocols and best practices are outlined in significant detail along with design considerations and notes of caution for pitfalls and factors impacting yield.

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  2. Signal Processing in Medical Ultrasound B-mode Imaging

    International Nuclear Information System (INIS)

    Song, Tai Kyong

    2000-01-01

    Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes 'main stream' digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing

  3. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of the pelvis may be obtained as an alternative imaging test, because it may be obtained with an external (phased array) receiver coil. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page This page ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... if a patient is at high risk for cancer. In this case, a biopsy is performed and an ... of the pelvis may be obtained as an alternative imaging test, because it may be obtained with an external (phased array) receiver ... of page This page was reviewed on ...

  6. Array capabilities and future arrays

    International Nuclear Information System (INIS)

    Radford, D.

    1993-01-01

    Early results from the new third-generation instruments GAMMASPHERE and EUROGAM are confirming the expectation that such arrays will have a revolutionary effect on the field of high-spin nuclear structure. When completed, GAMMASHPERE will have a resolving power am order of magnitude greater that of the best second-generation arrays. When combined with other instruments such as particle-detector arrays and fragment mass analysers, the capabilites of the arrays for the study of more exotic nuclei will be further enhanced. In order to better understand the limitations of these instruments, and to design improved future detector systems, it is important to have some intelligible and reliable calculation for the relative resolving power of different instrument designs. The derivation of such a figure of merit will be briefly presented, and the relative sensitivities of arrays currently proposed or under construction presented. The design of TRIGAM, a new third-generation array proposed for Chalk River, will also be discussed. It is instructive to consider how far arrays of Compton-suppressed Ge detectors could be taken. For example, it will be shown that an idealised open-quote perfectclose quotes third-generation array of 1000 detectors has a sensitivity an order of magnitude higher again than that of GAMMASPHERE. Less conventional options for new arrays will also be explored

  7. SNP Arrays

    Directory of Open Access Journals (Sweden)

    Jari Louhelainen

    2016-10-01

    Full Text Available The papers published in this Special Issue “SNP arrays” (Single Nucleotide Polymorphism Arrays focus on several perspectives associated with arrays of this type. The range of papers vary from a case report to reviews, thereby targeting wider audiences working in this field. The research focus of SNP arrays is often human cancers but this Issue expands that focus to include areas such as rare conditions, animal breeding and bioinformatics tools. Given the limited scope, the spectrum of papers is nothing short of remarkable and even from a technical point of view these papers will contribute to the field at a general level. Three of the papers published in this Special Issue focus on the use of various SNP array approaches in the analysis of three different cancer types. Two of the papers concentrate on two very different rare conditions, applying the SNP arrays slightly differently. Finally, two other papers evaluate the use of the SNP arrays in the context of genetic analysis of livestock. The findings reported in these papers help to close gaps in the current literature and also to give guidelines for future applications of SNP arrays.

  8. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  9. Ultrasound imaging using coded signals

    DEFF Research Database (Denmark)

    Misaridis, Athanasios

    coded excitation can be used for increasing the frame rate. The work includes both simulated results using Field II, and experimental results based on measurements on phantoms as well as clinical images. Initially a mathematical foundation of signal modulation is given. Pulse compression based...... is described. Application of coded excitation in array imaging is evaluated through simulations in Field II. The low degree of the orthogonality among coded signals for ultrasound systems is first discussed, and the effect of mismatched filtering in the cross-correlation properties of the signals is evaluated...... emissions. Finally, a novel coding technique which uses pulse train excitation is presented....

  10. Local frequency dependence in transcranial ultrasound transmission

    Energy Technology Data Exchange (ETDEWEB)

    White, P J; Clement, G T; Hynynen, K [Department of Radiology, Harvard Medical School, Brigham and Women' s Hospital, Boston, MA 02115 (United States)

    2006-05-07

    The development of large-aperture multiple-source transducer arrays for ultrasound transmission through the human skull has demonstrated the possibility of controlled and substantial acoustic energy delivery into the brain parenchyma without the necessitation of a craniotomy. The individual control of acoustic parameters from each ultrasound source allows for the correction of distortions arising from transmission through the skull bone and also opens up the possibility for electronic steering of the acoustic focus within the brain. In addition, the capability to adjust the frequency of insonation at different locations on the skull can have an effect on ultrasound transmission. To determine the efficacy and applicability of a multiple-frequency approach with such a device, this study examined the frequency dependence of ultrasound transmission in the range of 0.6-1.4 MHz through a series of 17 points on four ex vivo human skulls. Effects beyond those that are characteristic of frequency-dependent attenuation were examined. Using broadband pulses, it was shown that the reflected spectra from the skull revealed information regarding ultrasound transmission at specific frequencies. A multiple-frequency insonation with optimized frequencies over the entirety of five skull specimens was found to yield on average a temporally brief 230% increase in the transmitted intensity with an 88% decrease in time-averaged intensity transmission within the focal volume. This finding demonstrates a potential applicability of a multiple-frequency approach in transcranial ultrasound transmission.

  11. Ultrasound in Arthritis.

    Science.gov (United States)

    Sudoł-Szopińska, Iwona; Schueller-Weidekamm, Claudia; Plagou, Athena; Teh, James

    2017-09-01

    Ultrasound is currently performed in everyday rheumatologic practice. It is used for early diagnosis, to monitor treatment results, and to diagnose remission. The spectrum of pathologies seen in arthritis with ultrasound includes early inflammatory features and associated complications. This article discusses the spectrum of ultrasound features of arthritides seen in rheumatoid arthritis and other connective tissue diseases in adults, such as Sjögren syndrome, lupus erythematosus, dermatomyositis, polymyositis, and juvenile idiopathic arthritis. Ultrasound findings in spondyloarthritis, osteoarthritis, and crystal-induced diseases are presented. Ultrasound-guided interventions in patients with arthritis are listed, and the advantages and disadvantages of ultrasound are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Ultrasound of the Thyroid Gland

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound - Thyroid Thyroid ultrasound uses sound waves to produce pictures ... the Thyroid? What is an Ultrasound of the Thyroid? Ultrasound is safe and painless, and produces pictures ...

  13. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Breast Biopsy An ultrasound-guided breast biopsy uses ... of Ultrasound-Guided Breast Biopsy? What is Ultrasound-Guided Breast Biopsy? Lumps or abnormalities in the breast ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed to evaluate ... for ultrasound examinations. top of page What does the ultrasound equipment look like? Ultrasound scanners consist of ...

  15. Filter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  16. Large area MEMS based ultrasound device for cancer detection

    International Nuclear Information System (INIS)

    Wodnicki, Robert; Thomenius, Kai; Ming Hooi, Fong; Sinha, Sumedha P.; Carson, Paul L.; Lin Dersong; Zhuang Xuefeng; Khuri-Yakub, Pierre; Woychik, Charles

    2011-01-01

    We present image results obtained using a prototype ultrasound array that demonstrates the fundamental architecture for a large area MEMS based ultrasound device for detection of breast cancer. The prototype array consists of a tiling of capacitive Micromachined Ultrasound Transducers (cMUTs) that have been flip-chip attached to a rigid organic substrate. The pitch on the cMUT elements is 185 μm and the operating frequency is nominally 9 MHz. The spatial resolution of the new probe is comparable to those of production PZT probes; however the sensitivity is reduced by conditions that should be correctable. Simulated opposed-view image registration and Speed of Sound volume reconstruction results for ultrasound in the mammographic geometry are also presented.

  17. Large area MEMS based ultrasound device for cancer detection

    Science.gov (United States)

    Wodnicki, Robert; Thomenius, Kai; Ming Hooi, Fong; Sinha, Sumedha P.; Carson, Paul L.; Lin, Der-Song; Zhuang, Xuefeng; Khuri-Yakub, Pierre; Woychik, Charles

    2011-08-01

    We present image results obtained using a prototype ultrasound array that demonstrates the fundamental architecture for a large area MEMS based ultrasound device for detection of breast cancer. The prototype array consists of a tiling of capacitive Micromachined Ultrasound Transducers (cMUTs) that have been flip-chip attached to a rigid organic substrate. The pitch on the cMUT elements is 185 μm and the operating frequency is nominally 9 MHz. The spatial resolution of the new probe is comparable to those of production PZT probes; however the sensitivity is reduced by conditions that should be correctable. Simulated opposed-view image registration and Speed of Sound volume reconstruction results for ultrasound in the mammographic geometry are also presented.

  18. Large area MEMS based ultrasound device for cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Wodnicki, Robert, E-mail: wodnicki@research.ge.com [GE Global Research, 1 Research Circle, Niskayuna, NY 12309 (United States); Thomenius, Kai [GE Global Research, 1 Research Circle, Niskayuna, NY 12309 (United States); Ming Hooi, Fong; Sinha, Sumedha P.; Carson, Paul L. [Radiology and Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Lin Dersong; Zhuang Xuefeng; Khuri-Yakub, Pierre [Department of Electrical Engineering, Stanford University, Stanford, CA 94309 (United States); Woychik, Charles [GE Global Research, 1 Research Circle, Niskayuna, NY 12309 (United States)

    2011-08-21

    We present image results obtained using a prototype ultrasound array that demonstrates the fundamental architecture for a large area MEMS based ultrasound device for detection of breast cancer. The prototype array consists of a tiling of capacitive Micromachined Ultrasound Transducers (cMUTs) that have been flip-chip attached to a rigid organic substrate. The pitch on the cMUT elements is 185 {mu}m and the operating frequency is nominally 9 MHz. The spatial resolution of the new probe is comparable to those of production PZT probes; however the sensitivity is reduced by conditions that should be correctable. Simulated opposed-view image registration and Speed of Sound volume reconstruction results for ultrasound in the mammographic geometry are also presented.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  20. Prenatal ultrasound - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100197.htm Prenatal ultrasound - series—Procedure, part 1 To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Prenatal Testing Ultrasound A.D.A.M., Inc. is ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... color picture. It can also convert blood flow information into a distinctive sound that can be heard ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... diagnose heart conditions, and assess damage after a heart attack. Ultrasound is safe, noninvasive, and does not use ... heart failure, and to assess damage after a heart attack. Ultrasound of the heart is commonly called an “ ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... illness. Ultrasound is used to help physicians evaluate symptoms such as: pain swelling infection Ultrasound is a ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... called the Doppler effect). A computer collects and processes the sounds and creates graphs or color pictures ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... can be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ... is full when the scan begins. top of page What does the equipment look like? Ultrasound scanners consist ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  9. Point of Care Ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana

    2017-01-01

    Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allow...... and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training.......Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Angioplasty and ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure? Ultrasound examinations can help to diagnose a variety of conditions and to assess organ damage following ... the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart conditions, including valve problems and congestive ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... can only see the outer surface of bony structures and not what lies within (except in infants ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... for a procedure like angioplasty . top of page How should I prepare? You should wear comfortable, loose- ... are poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  19. Medical Ultrasound Imaging.

    Science.gov (United States)

    Hughes, Stephen

    2001-01-01

    Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Ultrasound examinations can help to diagnose a ... the scan begins. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of General Ultrasound Imaging? Ultrasound waves are ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... uterus and ovaries. top of page What will I experience during and after the procedure? Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is inserted into an opening of the body may produce minimal discomfort. If a Doppler ultrasound ...

  5. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate

  6. Breast ultrasound tomography with total-variation regularization

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTIT.; Duric, Neb [KARMANOS CANCER INSTIT

    2009-01-01

    Breast ultrasound tomography is a rapidly developing imaging modality that has the potential to impact breast cancer screening and diagnosis. A new ultrasound breast imaging device (CURE) with a ring array of transducers has been designed and built at Karmanos Cancer Institute, which acquires both reflection and transmission ultrasound signals. To extract the sound-speed information from the breast data acquired by CURE, we have developed an iterative sound-speed image reconstruction algorithm for breast ultrasound transmission tomography based on total-variation (TV) minimization. We investigate applicability of the TV tomography algorithm using in vivo ultrasound breast data from 61 patients, and compare the results with those obtained using the Tikhonov regularization method. We demonstrate that, compared to the Tikhonov regularization scheme, the TV regularization method significantly improves image quality, resulting in sound-speed tomography images with sharp (preserved) edges of abnormalities and few artifacts.

  7. Measurement of a PAGAT gel dosimeter by ultrasound computed tomography

    Science.gov (United States)

    Khoei, S.; Trapp, J. V.; Langton, C. M.

    2013-06-01

    In this work we used a 3D quantitative CT ultrasound imaging system to characterise polymer gel dosimeters. The system comprised of two identical 5 MHz 128 element phased-array ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound signals were generated and received using an Olympus Omniscan unit. Dose sensitivity of attenuation and time of flight ultrasonic parameters were assessed using this system.

  8. Plane Wave Medical Ultrasound Imaging Using Adaptive Beamforming

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund; Gran, Fredrik; Jensen, Jørgen Arendt

    2008-01-01

    In this paper, the adaptive, minimum variance (MV) beamformer is applied to medical ultrasound imaging. The Significant resolution and contrast gain provided by the adaptive, minimum variance (MV) beamformer, introduces the possibility of plane wave (PW) ultrasound imaging. Data is obtained using...... Field H and a 7 MHz, 128-elements, linear array transducer with lambda/2-spacing. MV is compared to the conventional delay-and-sum (DS) beamformer with Boxcar and Hanning weights. Furthermore, the PW images are compared to the a conventional ultrasound image, obtained from a linear scan sequence...

  9. Tunable microbubble generator using electrolysis and ultrasound

    OpenAIRE

    Younes Achaoui; Khaled Metwally; Damien Fouan; Zoubida Hammadi; Roger Morin; Eric Debieu; Cédric Payan; Serge Mensah

    2017-01-01

    This letter reports on a method for producing on demand calibrated bubbles in a non-chemically controlled solution using localized micro-electrolysis and ultrasound. Implementing a feedback loop in the process leads to a point source of stable mono-dispersed microbubbles. This approach overcomes the inertial constraints encountered in microfluidics with the possibility to produce from a single to an array of calibrated bubbles. Moreover, this method avoids the use of additional surfactant tha...

  10. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  11. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  12. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  13. Ultrasound techniques in the evaluation of the mediastinum, part I: endoscopic ultrasound (EUS), endobronchial ultrasound (EBUS) and transcutaneous mediastinal ultrasound (TMUS), introduction into ultrasound techniques

    NARCIS (Netherlands)

    Dietrich, Christoph Frank; Annema, Jouke Tabe; Clementsen, Paul; Cui, Xin Wu; Borst, Mathias Maximilian; Jenssen, Christian

    2015-01-01

    Ultrasound imaging has gained importance in pulmonary medicine over the last decades including conventional transcutaneous ultrasound (TUS), endoscopic ultrasound (EUS), and endobronchial ultrasound (EBUS). Mediastinal lymph node staging affects the management of patients with both operable and

  14. Use of ultrasound in the management of thyroid cancer.

    Science.gov (United States)

    Lew, John I; Solorzano, Carmen C

    2010-01-01

    The use of ultrasound for thyroid cancer has evolved dramatically over the last few decades. Since the late 1960s, ultrasound has become essential in the examination of the thyroid gland with the increased availability of high-frequency linear array transducers and computer-enhanced imaging capabilities of modern day portable ultrasound equipment in a clinic- or office-based setting. As a noninvasive, rapid, and easily reproducible imaging study, ultrasound has been demonstrated to have a broadened utility beyond the simple confirmation of thyroid nodules and their sizes. Recently, office-based ultrasound has become an integral part of clinical practice, where it has demonstrated overwhelming benefits to patients being evaluated and treated for thyroid cancer. Ultrasound has become useful in the qualitative characterization of thyroid nodules based on benign or malignant features. On the basis of such classifications and the relative risk for thyroid malignancy, the need for ultrasound-guided fine-needle aspiration, preoperative and intraoperative staging, lymph node mapping, and the extent of surgery can subsequently be determined. Furthermore, ultrasound has additional value in the surveillance of patients treated for thyroid cancer.

  15. Simulating CMUT Arrays Using Time Domain FEA

    DEFF Research Database (Denmark)

    Engholm, Mathias; Tweedie, Andrew; Jensen, Jonas

    2017-01-01

    PZFlex is a commercial FEA software that has been optimized for the ultrasound industry and is commonly used to design piezoelectric ultrasound transducers. However, PZFlex is not commonly used within the CMUT research field. Nevertheless, it has an explicit modeling approach allowing large...... structures like CMUT arrays to be modeled and its transient analysis intrinsically supplies non-linear and broadband results from a single run. A 3-D model of a CMUT array is developed with multiple cells in each element and one active element surrounded by N passive elements. It is demonstrated...... that the impulse response can directly be used in Field II to assess the image quality of the transducer using the lateral, axial and cystic resolution for two different CMUT designs....

  16. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  17. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    International Nuclear Information System (INIS)

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of ... 30 minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... such as the liver or kidneys. top of page What are some common uses of the procedure? Abdominal ... is rarely needed for ultrasound examinations. top of page What does the ultrasound equipment look like? Ultrasound scanners ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of Abdominal Ultrasound Imaging? What is Abdominal Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? Abdominal ...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... ultrasound images are reviewed. An ultrasound examination is usually ...

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... proper blood flow into it. top of page How should we prepare for an abdominal ultrasound exam? ... are poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of the ... abdomen using ultrasound. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  5. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...... on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  7. Membrane design of an all-optical ultrasound receiver

    NARCIS (Netherlands)

    Leinders, S.M.; Dongen, K.W.A. van; Jong, N. de; Verweij, M.D.; Westerveld, W.J.; Urbach, H.P.; Neer, P.L.M.J. van; Pozo Torres, J.M.

    2013-01-01

    Ultrasound sensors such as piezoelectric transducers and CMUTs are successfully used for medical imaging. However, especially wiring of individual elements is difficult in the fabrication of small piezoelectric arrays, used in, e.g. the field of intravascular imaging. As an alternative, we designed

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  9. A cMUT probe for ultrasound-guided focused ultrasound targeted therapy.

    Science.gov (United States)

    Gross, Dominique; Coutier, Caroline; Legros, Mathieu; Bouakaz, Ayache; Certon, Dominique

    2015-06-01

    Ultrasound-mediated targeted therapy represents a promising strategy in the arsenal of modern therapy. Capacitive micromachined ultrasonic transducer (cMUT) technology could overcome some difficulties encountered by traditional piezoelectric transducers. In this study, we report on the design, fabrication, and characterization of an ultrasound-guided focused ultrasound (USgFUS) cMUT probe dedicated to preclinical evaluation of targeted therapy (hyperthermia, thermosensitive liposomes activation, and sonoporation) at low frequency (1 MHz) with simultaneous ultrasonic imaging and guidance (15 to 20 MHz). The probe embeds two types of cMUT arrays to perform the modalities of targeted therapy and imaging respectively. The wafer-bonding process flow employed for the manufacturing of the cMUTs is reported. One of its main features is the possibility of implementing two different gap heights on the same wafer. All the design and characterization steps of the devices are described and discussed, starting from the array design up to the first in vitro measurements: optical (microscopy) and electrical (impedance) measurements, arrays' electroacoustic responses, focused pressure field mapping (maximum peak-to-peak pressure = 2.5 MPa), and the first B-scan image of a wire-target phantom.

  10. Applications of airborne ultrasound in human-computer interaction.

    Science.gov (United States)

    Dahl, Tobias; Ealo, Joao L; Bang, Hans J; Holm, Sverre; Khuri-Yakub, Pierre

    2014-09-01

    Airborne ultrasound is a rapidly developing subfield within human-computer interaction (HCI). Touchless ultrasonic interfaces and pen tracking systems are part of recent trends in HCI and are gaining industry momentum. This paper aims to provide the background and overview necessary to understand the capabilities of ultrasound and its potential future in human-computer interaction. The latest developments on the ultrasound transducer side are presented, focusing on capacitive micro-machined ultrasonic transducers, or CMUTs. Their introduction is an important step toward providing real, low-cost multi-sensor array and beam-forming options. We also provide a unified mathematical framework for understanding and analyzing algorithms used for ultrasound detection and tracking for some of the most relevant applications. Copyright © 2014. Published by Elsevier B.V.

  11. Silicon photonic micro-ring resonators to sense strain and ultrasound

    NARCIS (Netherlands)

    Westerveld, W.J.

    2014-01-01

    We demonstrated that photonic micro-ring resonators can be used in micro-machined ultrasound microphones. This might cause a breakthrough in array transducers for ultrasonography; first because optical multiplexing allows array interrogation via one optical fiber and second because the

  12. Portable Ultrasound Imaging

    DEFF Research Database (Denmark)

    di Ianni, Tommaso

    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging ...

  14. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  15. Ultrasound: Bladder (For Parents)

    Science.gov (United States)

    ... If You Have Questions Print en español Ultrasonido: vejiga What It Is A bladder ultrasound is a safe and painless test that ... Exam: Voiding Cystourethrogram (VCUG) Ultrasound: Renal (Kidneys, Ureters, Bladder) Urinary ... only. For specific medical advice, diagnoses, and treatment, consult your doctor. © 1995- The Nemours Foundation. All ...

  16. Carotid Ultrasound Imaging

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... while the ultrasound images are reviewed. The branches of the carotid ...

  17. MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z. [University of Chicago (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  18. MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Sammet, S. [University of Chicago Medical Center (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  19. MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

    International Nuclear Information System (INIS)

    Sammet, S.

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  20. MO-AB-210-03: Workshop [Advancements in high intensity focused ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z. [University of Chicago (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  1. Wireless image streaming in mobile ultrasound.

    Science.gov (United States)

    Dickson, Brett W; Pedersen, Peder C

    2010-03-01

    This work evaluates the feasibility of using 802.11 g ad hoc and 3G cellular broadband networks to wirelessly stream ultrasound video in real-time. Telemedicine ultrasound applications in events such as disaster relief and first-response triage can incorporate these technologies, enabling onsite medical personnel to receive assistance with diagnostic decisions by remote medical experts. The H.264 scalable video codec was used to encode echocardiographic video streams at various image resolutions (video graphics array [VGA] and quarter video graphics array [QVGA]) and frame rates (10, 15, 20, and 30 frames/s). The video stream was transmitted using 802.11 g and 3G cellular technologies, and pertinent transmission parameters such as data rate, packet loss, delay jitter, and latency were measured. 802.11 g permits high frame rate and VGA resolution and has low latency and jitter, but it is suitable only for short communication ranges, whereas the 3G cellular network allows medium to low frame rate streaming at QVGA image resolution with medium latency. However, video streaming can take place from any location with 3G service to any other site with Internet connectivity. The transmitted ultrasound video streams were subsequently recorded and evaluated by physicians with expertise in medical ultrasonography who evaluated the diagnostic value of the received video streams relative to the original videos. They expressed the opinion that image quality in the case of both 802.11 g and 3G was fully to adequately preserved, but missed frames could momentarily decrease the diagnostic value. This research demonstrates that 3G and 802.11 g wireless networks combined with efficient video compression make diagnostically valuable wireless streaming of ultrasound video feasible.

  2. Coupling in reflector arrays

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen

    1968-01-01

    In order to reduce the space occupied by a reflector array, it is desirable to arrange the array antennas as close to each other as possible; however, in this case coupling between the array antennas will reduce the reflecting properties of the reflector array. The purpose of the present communic......In order to reduce the space occupied by a reflector array, it is desirable to arrange the array antennas as close to each other as possible; however, in this case coupling between the array antennas will reduce the reflecting properties of the reflector array. The purpose of the present...

  3. WE-H-209-01: Advances in Ultrasound Therapy

    International Nuclear Information System (INIS)

    Hynynen, K.

    2016-01-01

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives: Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments

  4. Ultrasound-based guidance of intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Fung, Albert Y.C.; Ayyangar, Komanduri M.; Djajaputra, David; Nehru, Ramasamy M.; Enke, Charles A.

    2006-01-01

    In ultrasound-guided intensity-modulated radiation therapy (IMRT) of prostate cancer, ultrasound imaging ascertains the anatomical position of patients during x-ray therapy delivery. The ultrasound transducers are made of piezoelectric ceramics. The same crystal is used for both ultrasound production and reception. Three-dimensional (3D) ultrasound devices capture and correlate series of 2-dimensional (2D) B-mode images. The transducers are often arranged in a convex array for focusing. Lower frequency reaches greater depth, but results in low resolution. For clear image, some gel is usually applied between the probe and the skin contact surface. For prostate positioning, axial and sagittal scans are performed, and the volume contours from computed tomography (CT) planning are superimposed on the ultrasound images obtained before radiation delivery at the linear accelerator. The planning volumes are then overlaid on the ultrasound images and adjusted until they match. The computer automatically deduces the offset necessary to move the patient so that the treatment area is in the correct location. The couch is translated as needed. The currently available commercial equipment can attain a positional accuracy of 1-2 mm. Commercial manufacturer designs differ in the detection of probe coordinates relative to the isocenter. Some use a position-sensing robotic arm, while others have infrared light-emitting diodes or pattern-recognition software with charge-couple-device cameras. Commissioning includes testing of image quality and positional accuracy. Ultrasound is mainly used in prostate positioning. Data for 7825 daily fractions of 234 prostate patients indicated average 3D inter-fractional displacement of about 7.8 mm. There was no perceivable trend of shift over time. Scatter plots showed slight prevalence toward superior-posterior directions. Uncertainties of ultrasound guidance included tissue inhomogeneities, speckle noise, probe pressure, and inter

  5. Tissue Harmonic Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Rasmussen, Joachim; Jensen, Jørgen Arendt

    2014-01-01

    Synthetic aperture sequential beamforming (SASB) and tissue har- monic imaging (THI) are combined to improve the image quality of medical ultrasound imaging. The technique is evaluated in a compar- ative study against dynamic receive focusing (DRF). The objective is to investigate if SASB combined......, and data were recorded with and without pulse inversion for tissue harmonic imaging. Data were acquired using a Sound Technol- ogy 192 element convex array transducer from both a wire phantom and a tissue mimicking phantom to investigate spatial resolution and pen- etration. In-vivo scans were also...

  6. Tunable microbubble generator using electrolysis and ultrasound

    Science.gov (United States)

    Achaoui, Younes; Metwally, Khaled; Fouan, Damien; Hammadi, Zoubida; Morin, Roger; Debieu, Eric; Payan, Cédric; Mensah, Serge

    2017-01-01

    This letter reports on a method for producing on demand calibrated bubbles in a non-chemically controlled solution using localized micro-electrolysis and ultrasound. Implementing a feedback loop in the process leads to a point source of stable mono-dispersed microbubbles. This approach overcomes the inertial constraints encountered in microfluidics with the possibility to produce from a single to an array of calibrated bubbles. Moreover, this method avoids the use of additional surfactant that may modify the composition of the host fluid. It impacts across a broad range of scientific domains from bioengineering, sensing to environment.

  7. Tunable microbubble generator using electrolysis and ultrasound

    Directory of Open Access Journals (Sweden)

    Younes Achaoui

    2017-01-01

    Full Text Available This letter reports on a method for producing on demand calibrated bubbles in a non-chemically controlled solution using localized micro-electrolysis and ultrasound. Implementing a feedback loop in the process leads to a point source of stable mono-dispersed microbubbles. This approach overcomes the inertial constraints encountered in microfluidics with the possibility to produce from a single to an array of calibrated bubbles. Moreover, this method avoids the use of additional surfactant that may modify the composition of the host fluid. It impacts across a broad range of scientific domains from bioengineering, sensing to environment.

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can ... Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... because greater amounts of tissue attenuate (weaken) the sound waves as they pass deeper into the body and need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... organs and to examine a baby in pregnant women and the brain and hips in infants. It’s ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... can often determine whether a patient is a good candidate for a procedure like angioplasty . top of ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test ... that allows the physician to see and evaluate blood flow through arteries and veins in the abdomen, ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... by a computer, which in turn creates a real-time picture on the monitor. One or more ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Videos related to General Ultrasound Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Angioplasty and Vascular Stenting ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...