WorldWideScience

Sample records for droplet dye laser

  1. Levitated droplet dye laser

    DEFF Research Database (Denmark)

    Azzouz, H.; Alkafadiji, L.; Balslev, Søren

    2006-01-01

    a high quality optical resonator. Our 750 nL lasing droplets consist of Rhodamine 6G dissolved in ethylene glycol, at a concentration of 0.02 M. The droplets are optically pumped at 532 nm light from a pulsed, frequency doubled Nd:YAG laser, and the dye laser emission is analyzed by a fixed grating...

  2. Laser Dyes

    Indian Academy of Sciences (India)

    amplification or generation of coherent light waves in the UV,. VIS, and near IR region. .... ciency in most flashlamp pumped dye lasers. It is used as reference dye .... have led to superior laser dyes with increased photostabilities. For instance ...

  3. uv dye lasers

    International Nuclear Information System (INIS)

    Abakumov, G.A.; Fadeev, V.V.; Khokhlov, R.V.; Simonov, A.P.

    1975-01-01

    The most important property of visible dye lasers, that is, continuous wavelength tuning, stimulated the search for dyes capable to lase in uv. They were found in 1968. Now the need for tunable uv lasers for applications in spectroscopy, photochemistry, isotope separation, remote air and sea probing, etc. is clearly seen. A review of some recent advances in uv dye lasers is reviewed

  4. Tunable Microfluidic Dye Laser

    DEFF Research Database (Denmark)

    Olsen, Brian Bilenberg; Helbo, Bjarne; Kutter, Jörg Peter

    2003-01-01

    We present a tunable microfluidic dye laser fabricated in SU-8. The tunability is enabled by integrating a microfluidic diffusion mixer with an existing microfluidic dye laser design by Helbo et al. By controlling the relative flows in the mixer between a dye solution and a solvent......, the concentration of dye in the laser cavity can be adjusted, allowing the wavelength to be tuned. Wavelength tuning controlled by the dye concentration was demonstrated with macroscopic dye lasers already in 1971, but this principle only becomes practically applicable by the use of microfluidic mixing...

  5. for aqueous dye lasers

    Indian Academy of Sciences (India)

    2014-02-12

    Feb 12, 2014 ... inclusion complex of RhB with the container molecule cucurbit[7]uril (CB[7]). Keywords. Temperature-dependent fluorescence; Rhodamine B; cucurbit[7]uril; host–guest complex; dye laser. PACS Nos 36.20.kd; 83.60.pq; 87.64.kv. 1. Introduction. Rhodamine B (RhB) is an efficient and photostable laser dye ...

  6. Microfluidic Dye Lasers

    DEFF Research Database (Denmark)

    Kristensen, Anders; Balslev, Søren; Gersborg-Hansen, Morten

    2006-01-01

    A technology for miniaturized, polymer based lasers, suitable for integration with planar waveguides and microfluidic networks is presented. The microfluidic dye laser device consists of a microfluidic channel with an embedded optical resonator. The devices are fabricated in a thin polymer film...

  7. Dye laser principles with applications

    CERN Document Server

    Duarte, Frank J; Liao, Peter F; Kelley, Paul

    1990-01-01

    A tutorial introduction to the field of dye lasers, Dye Laser Principles also serves as an up-to-date overview for those using dye lasers as research and industrial tools. A number of the issues discussed in this book are pertinent not only to dye lasers but also to lasers in general. Most of the chapters in the book contain problem sets that expand on the material covered in the chapter.Key Features* Dye lasers are among the most versatile and successful laser sources currently available in use Offering both pulsed and continuous-wave operation and tunable from the near ultraviole

  8. Dye lasers in atomic spectroscopy

    International Nuclear Information System (INIS)

    Lange, W.; Luther, J.; Steudel, A.

    1974-01-01

    The properties of dye lasers which are relevant to atomic spectroscopy are discussed. Several experiments made possible by tunable dye lasers are discussed. Applications of high spectral density dye lasers are covered in areas such as absorption spectroscopy, fluorescence spectroscopy, photoionization and photodetachment, and two- and multi-photon processes. Applications which take advantage of the narrow bandwidth of tunable dye lasers are discussed, including saturation spectroscopy, fluorescence line narrowing, classic absorption and fluorescence spectroscopy, nonoptical detection of optical resonances, heterodyne spectroscopy, and nonlinear coherent resonant phenomena. (26 figures, 180 references) (U.S.)

  9. CW organic dye laser

    International Nuclear Information System (INIS)

    Tuccio, S.A.; Peterson, O.G.

    1975-01-01

    A method and apparatus for producing continuous emission from a lasing medium comprising organic dye molecules in solution are described. Continuous emission is accomplished by flowing the medium through a focused optical cavity while simultaneously producing a population inversion in that portion of the medium flowing in close proximity to the focal point of the cavity. The population inversion is produced by pumping the medium longitudinally, along the optical axis of the cavity, preferably by the focused output of a continuous-wave argon laser. Sufficient thermal energy is continuously dissipated from the medium to maintain the optical homogeneity thereof at or above the quality required for continuous emission

  10. Development of AVLIS dye laser system

    International Nuclear Information System (INIS)

    Sugiyama, Akira; Nakayama, Tsuyoshi; Kato, Masaaki; Arisawa, Takashi

    1995-01-01

    CVL pumped single mode dye laser was performed. It was found that pressure tuning has some excellent feature in comparison to mechanical tuning in dye laser frequency control. For evaluation of dye laser amplifier, two-dimensional rate equation was proposed. Calculated data by this equation agreed with experimental data in large diameter input dye laser beam condition. (author)

  11. Broad band exciplex dye lasers

    International Nuclear Information System (INIS)

    Dienes, A.; Shank, C.V.; Trozzolo, A.M.

    1975-01-01

    The disclosure is concerned with exciplex dye lasers, i.e., lasers in which the emitting species is a complex formed only from a constituent in an electronically excited state. Noting that an exciplex laser, favorable from the standpoint of broad tunability, results from a broad shift in the peak emission wavelength for the exciplex relative to the unreacted species, a desirable class resulting in such broad shift is described. Preferred classes of laser media utilizing specified resonant molecules are set forth. (auth)

  12. Tunability of optofluidic distributed feedback dye lasers

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Kristensen, Anders

    2007-01-01

    We investigate the tunability of optofluidic distributed feedback (DFB) dye lasers. The lasers rely on light-confinement in a nano-structured polymer film where an array of nanofluidic channels constitutes a third order Bragg grating DFB laser resonator with a central phase-shift. The lasers...... are operated by filling the DFB laser resonator with a dye solution by capillary action and optical pumping with a frequency doubled Nd: YAG laser. The low reflection order of the DFB laser resonator yields low out-of-plane scattering losses as well as a large free spectral range (FSR), and low threshold...... fluences down to similar to 7 mu J/mm2 are observed. The large FSR facilitates wavelength tuning over the full gain spectrum of the chosen laser dye and we demonstrate 45 nm tunability using a single laser dye by changing the grating period and dye solution refractive index. The lasers are straight...

  13. Feasibility of solar-pumped dye lasers

    Science.gov (United States)

    Lee, Ja H.; Kim, Kyung C.; Kim, Kyong H.

    1987-01-01

    Dye laser gains were measured at various pump-beam irradiances on a dye cell in order to evaluate the feasibility of solar pumping. Rhodamine 6G dye was considered as a candidate for the solar-pumped laser because of its high utilization of the solar spectrum and high quantum efficiency. Measurements show that a solar concentration of 20,000 is required to reach the threshold of the dye.

  14. Radiative characteristics of CVL pumped dye laser

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Uichi; Ishiguro, Takahide

    1987-09-01

    This paper describes the radiative characteristics of CVL pumped dye laser. It is compared YAG-SH (530 nm) with CVL (511, 578 nm) and CVL (511 nm) for pumping source. Influence of solvent in dye laser power was examined. The present experimental results show that efficiency of CVL (511 nm) pumped dye laser was most high. When the dye solution is at a standstill, the efficiency of dye laser with water and Sodium Lauryl Sulfate (S.L.S., 2 %wt.) was most high among the four kinds of solvent. In the condition of dye solution flow, the water and S.L.S. or ethylene glycol was useful solvent for dye laser.

  15. Radiative characteristics of CVL pumped dye laser

    International Nuclear Information System (INIS)

    Kubo, Uichi; Ishiguro, Takahide.

    1987-01-01

    This paper describes the radiative characteristics of CVL pumped dye laser. It is compared YAG-SH (530 nm) with CVL (511, 578 nm) and CVL (511 nm) for pumping source. Influence of solvent in dye laser power was examined. The present experimental results show that efficiency of CVL (511 nm) pumped dye laser was most high. When the dye solution is at a standstill, the efficiency of dye laser with water and Sodium Lauryl Sulfate (S.L.S., 2 %wt.) was most high among the four kinds of solvent. In the condition of dye solution flow, the water and S.L.S. or Ethylene Glycol was useful solvent for dye laser. (author)

  16. Droplet based cavities and lasers

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Kristensen, Anders; Mortensen, Asger

    2009-01-01

    The self-organized and molecularly smooth surface on liquid microdroplets makes them attractive as optical cavities with very high quality factors. This chapter describes the basic theory of optical modes in spherical droplets. The mechanical properties including vibrational excitation are also d...

  17. Micro-Cavity Fluidic Dye Laser

    DEFF Research Database (Denmark)

    Helbo, Bjarne; Kristensen, Anders; Menon, Aric Kumaran

    2003-01-01

    We have successfully designed, fabricated and characterized a micro-cavity fluidic dye laser with metallic mirrors, which can be integrated with polymer based lab-on-a-chip microsystems without further processing steps. A simple rate-equation model is used to predict the average pumping power...... threshold for lasing as function of cavity-mirror reflectance, laser dye concentration and cavity length. The laser device is characterized using the laser dye Rhodamine 6G dissolved in ethanol. Lasing is observed, and the influence of dye concentration is investigated....

  18. Polymer dye lasers

    DEFF Research Database (Denmark)

    Balslev, Søren

    2006-01-01

    , elektronstrålelithografi og Röntgenstrålelithografi. Andre polymerer er også blevet formgivet via ”nanoimprint” lithografi for at skabe laserresonatorer. En række lasere, både baseret på et flydende forstærkningsmedium og et faststof forstærkningsrmedium er blevet udviklet. Laserne giver både lys i flere ”modes” og i een......Formålet med dette Ph.D. arbejde har været at udvikle miniaturiserede polymer farvestoflasere, egnet til at blive integreret i mikrochips som også indeholder andre polymerstrukturer – som for eksempel kan findes i ”Laboratorie-på-en-chip” kredsløb. Lasernes funktion skal være at levere lys til...... meget følsomme sensorformål, og at undgå at skulle opliniere eksterne lyskilder til sensorer på polymerchips. En enkelt type gennemsigtig ”resist” (SU-8) er blevet brugt til at udvikle en række laserresonatorer i polymer. ”Resisten” er blevet formgivet via en række lithografiske teknikker: UV lithografi...

  19. Low-threshold conical microcavity dye lasers

    DEFF Research Database (Denmark)

    Grossmann, Tobias; Schleede, Simone; Hauser, Mario

    2010-01-01

    element simulations confirm that lasing occurs in whispering gallery modes which corresponds well to the measured multimode laser-emission. The effect of dye concentration on lasing threshold and lasing wavelength is investigated and can be explained using a standard dye laser model....

  20. Simulations of longitudinally pumped dye laser amplifier

    International Nuclear Information System (INIS)

    Takehisa, Kiwamu; Takemori, Satoshi

    1995-01-01

    Simulations of a copper laser pumped dye laser amplifier and new designs of the longitudinally pumped dye laser amplifier are presented. The simulations take the consideration of the amplified spontaneous emission (ASE). The new designs utilize a center-hole reflector instead of a dichroic mirror. The simulation results indicate that the poor spatial overlap between the pump beam and the dye beam in the transverse pumping not only reduces the laser output power, but also generates ASE strongly. The results also indicate that the longitudinal pumping is as efficient as the transverse pumping. (author)

  1. Computer control of pulsed tunable dye lasers

    International Nuclear Information System (INIS)

    Thattey, S.S.; Dongare, A.S.; Suri, B.M.; Nair, L.G.

    1992-01-01

    Pulsed tunable dye lasers are being used extensively for spectroscopic and photo-chemical experiments, and a system for acquisition and spectral analysis of a volume of data generated will be quite useful. The development of a system for wavelength tuning and control of tunable dye lasers and an acquisition system for spectral data generated in experiments with these lasers are described. With this system, it is possible to control the tuning of three lasers, and acquire data in four channels, simultaneously. It is possible to arrive at the desired dye laser wavelength with a reproducibility of ± 0.012 cm -1 , which is within the absorption width (atomic interaction) caused by pulsed dye lasers of linewidth 0.08 cm -1 . The spectroscopic data generated can be analyzed for spectral identification within absolute accuracy ± 0.012 cm -1 . (author). 6 refs., 11 figs

  2. Holograms made with a pulsed dye laser

    International Nuclear Information System (INIS)

    Fernandez-Guasti, M.; Iturbe-Castillo, D.; Silva-Perez, A.; Gil-Villegas, A.; Gonzalez-Torres, H.; Lopez-Guerrero, R.

    1989-01-01

    We report the obtention of holograms with a nitrogen pumped dye laser, whose source is inherently pulsed. We review the advantages and posibilities of holograms of moving objects which are impossible to make with CW lasers. The lasers used in these experiments were designed and built in the quantum optics laboratory at the Universidad Autonoma Metropolitana-Iztapalapa. (Author)

  3. Nanoimprinted polymer photonic crystal dye lasers

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Smith, Cameron; Buss, Thomas

    2010-01-01

    Optically pumped polymer photonic crystal band-edge dye lasers are presented. The photonic crystal is a rectangular lattice providing laser feedback as well as an optical resonance for the pump light. The lasers are defined in a thin film of photodefinable Ormocore hybrid polymer, doped...

  4. Excimer Pumped Pulsed Tunable Dye Laser

    Science.gov (United States)

    Littman, Michael G.

    1988-06-01

    It has been recently shown and reported for the first time at this meeting, that Excimer pumping of a single-mode, short-cavity, grazing-incidence, longitudinally-pumped pulsed dye laser is feasible. In this paper the key concepts upon which this latest development is based are presented and are in a somewhat unusual form. This manuscript describes five specific dye laser examples. The five examples represent a progression from the simplest type of dye laser to the single-mode version mentioned above. The examples thus serve as a tutorial introduction to potential users of dye lasers. The article is organized into five sections or STEPS, each of which describes a different pulsed dye laser. Since the subtle points about dye lasers are best appreciated only after one actually attempts to build a working model, a PROCEDURES category is included in which details about the construction of the particular form of laser are given. As one reads through this category, think of it as looking over the shoulder of the laser builder. The NOTES category which follows is a brief but essential discussion explaining why various components and procedures are used, as well as how laser performance specifications are obtained. This subsection can he viewed as a discussion with the laser builder concerning the reasons for specific actions and choices made in the assembly of the example laser. The last category contains COMMENTS which provide additional related information pertaining to the example laser that goes beyond the earlier annotated discussion. If you like, these are the narrator's comments. At the end of the article, after the five sequential forms of the laser have been presented, there is a brief summation.

  5. Supersonic laser-induced jetting of aluminum micro-droplets

    Energy Technology Data Exchange (ETDEWEB)

    Zenou, M. [Racah Institute of Physics and the Harvey M. Kruger Family Center for Nano-science and Nanotechnology, The Hebrew University of Jerusalem, 91904 Jerusalem (Israel); Additive Manufacturing Lab, Orbotech Ltd., P.O. Box 215, 81101 Yavne (Israel); Sa' ar, A. [Racah Institute of Physics and the Harvey M. Kruger Family Center for Nano-science and Nanotechnology, The Hebrew University of Jerusalem, 91904 Jerusalem (Israel); Kotler, Z. [Additive Manufacturing Lab, Orbotech Ltd., P.O. Box 215, 81101 Yavne (Israel)

    2015-05-04

    The droplet velocity and the incubation time of pure aluminum micro-droplets, printed using the method of sub-nanosecond laser induced forward transfer, have been measured indicating the formation of supersonic laser-induced jetting. The incubation time and the droplet velocity were extracted by measuring a transient electrical signal associated with droplet landing on the surface of the acceptor substrate. This technique has been exploited for studying small volume droplets, in the range of 10–100 femto-litters for which supersonic velocities were measured. The results suggest elastic propagation of the droplets across the donor-to-acceptor gap, a nonlinear deposition dynamics on the surface of the acceptor and overall efficient energy transfer from the laser beam to the droplets.

  6. Supersonic laser-induced jetting of aluminum micro-droplets

    International Nuclear Information System (INIS)

    Zenou, M.; Sa'ar, A.; Kotler, Z.

    2015-01-01

    The droplet velocity and the incubation time of pure aluminum micro-droplets, printed using the method of sub-nanosecond laser induced forward transfer, have been measured indicating the formation of supersonic laser-induced jetting. The incubation time and the droplet velocity were extracted by measuring a transient electrical signal associated with droplet landing on the surface of the acceptor substrate. This technique has been exploited for studying small volume droplets, in the range of 10–100 femto-litters for which supersonic velocities were measured. The results suggest elastic propagation of the droplets across the donor-to-acceptor gap, a nonlinear deposition dynamics on the surface of the acceptor and overall efficient energy transfer from the laser beam to the droplets

  7. Control of the droplet generation by an infrared laser

    Directory of Open Access Journals (Sweden)

    Zhibin Wang

    2018-01-01

    Full Text Available In this work, the control of the droplet generation by a focused infrared (IR laser with a wavelength of 1550 nm was studied, in which the liquid water and the oil with the surfactant of Span 80 were employed as the disperse and continuous phases, respectively. The characteristics of the droplet generation controlled by the laser was explored under various flow rates, laser powers and spot positions and the comparison between the cases with/without the laser was also performed. The results showed that when the laser was focused on the region away from the outlet of the liquid water inflow channel, the droplet shedding was blocked due to the IR laser heating induced thermocapillary flow, leading to the increase of the droplet volume and the cycle time of the droplet generation as compared to the case without the laser. Decreasing the continuous phase flow rate led to the increase of the droplet volume, cycle time of the droplet generation and the volume increase ratio, while increasing the disperse phase flow rate led to the increase of the droplet volume and the decrease of the cycle time and volume increase ratio. For a given flow rate ratio between the continuous and disperse phases, the increase of the flow rates decreased the volume increase ratio. In addition, it is also found that the droplet volume, the cycle time and the volume increase ratio all increased with the laser power. When the laser was focused at the inlet of the downstream channel, the droplet volume, the cycle time and the volume increase ratio were the largest. Moving the laser spot to the downstream or upstream led to the decrease of them. When the laser was focused on the outlet of the liquid water inflow channel, the generated droplet volume and cycle time of the droplet generation were even lower than the case without the laser because of the lowered viscosity. This works provides a comprehensive understanding of the characteristics of the droplet generation controlled

  8. Bleaching and diffusion dynamics in optofluidic dye lasers

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Balslev, Søren; Mortensen, Asger

    2007-01-01

    The authors have investigated the bleaching dynamics that occur in optofluidic dye lasers where the liquid laser dye in a microfluidic channel is locally bleached due to optical pumping. They find that for microfluidic devices, the dye bleaching may be compensated through diffusion of dye molecules...

  9. Efficiencies of laser dyes for atomic vapor laser isotope separation

    International Nuclear Information System (INIS)

    Maeda, Mitsuo; Oki, Yuji; Uchiumi, Michihiro; Takao, Takayuki; Igarashi, Kaoru; Shimamoto, Kojiro.

    1995-01-01

    Efficiencies of 30 laser dyes for the atomic vapor laser isotope separation (AVLIS) are experimentally evaluated with a dye laser pumped by a frequency-doubled Nd:YAG laser. On the other hand, a simulation code is developed to describe the laser action of Rhodamine 6G, and the dependence of the laser efficiency on the pump wavelength is calculated. Following conclusions are obtained by these considerations:space: 1) Pyrromethene 567 showed 16% higher laser efficiency than Rhodamine 6G by 532 nm pumping, and Pyrromethene 556 has an ability to provide better efficiency by green light pumping with a Cu vapor laser; 2) Kiton red 620 and Rhodamine 640, whose efficiencies were almost the same as Rhodamine 6G by 532 nm pumping, will show better efficiencies by two-wavelength pumping with a Cu vapor laser. (author)

  10. Optofluidic third order distributed feedback dye laser

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Kristensen, Anders

    2006-01-01

    which has a refractive index lower than that of the polymer. In combination with a third order DFB grating, formed by the array of nanofluidic channels, this yields a low threshold for lasing. The laser is straightforward to integrate on lab-on-a-chip microsystems where coherent, tunable light......This letter describes the design and operation of a polymer-based third order distributed feedback (DFB) microfluidic dye laser. The device relies on light confinement in a nanostructured polymer film where an array of nanofluidic channels is filled by capillary action with a liquid dye solution...

  11. A dye center laser pumped by emission from copper vapor and dye lasers

    Energy Technology Data Exchange (ETDEWEB)

    Loktyushin, A A; Chernyshev, A I; Soldatov, A N; Sukhanov, V B; Troitskiy, V O

    1983-01-01

    LiF:F2+ lasing is reported for the case of pumping by total emission with frequencies of 570.6 and 578.2 nanometers or by a single yellow copper vapor laser line and emission from an oxazene-17 dye laser excited by emission from a Cu laser. Lasing with a mean power level of 23 milliwatts with a maximum at 911 nanometers is obtained. The maximum efficiency was 3.4 percent with pumping of the dye centers by emission from the yellow Cu laser line. The lasing characteristics of the laser for all the types of pumping used are given.

  12. Characteristics of a Broadband Dye Laser Using Pyrromethene and Rhodamine Dyes

    Science.gov (United States)

    Tedder, Sarah A.; Danehy, Paul M.; Wheeler, Jeffrey L.

    2011-01-01

    A broadband dye laser pumped by a frequency-doubled Nd:YAG laser with a full-width half-maximum (FWHM) from 592 to 610 nm was created for the use in a dual-pump broadband CARS system called WIDECARS. The desired broadband dye laser was generated with a mixture of Pyrromethene dyes as an oscillator gain medium and a spectral selective optic in the oscillator cavity. A mixture of Rhodamine dyes were used in the amplifier dye cell. To create this laser a study was performed to characterize the spectral behavior of broadband dye lasers created with Rhodamine dyes 590, 610, and 640, Pyrromethene dyes 597 and 650 as well as mixture of these dyes.

  13. Laser Techniques on Acoustically Levitated Droplets

    Science.gov (United States)

    Cannuli, Antonio; Caccamo, Maria Teresa; Castorina, Giuseppe; Colombo, Franco; Magazù, Salvatore

    2018-01-01

    This work reports the results of an experimental study where laser techniques are applied to acoustically levitated droplets of trehalose aqueous solutions in order to perform spectroscopic analyses as a function of concentration and to test the theoretical diameter law. The study of such systems is important in order to better understand the behaviour of trehalose-synthesizing extremophiles that live in extreme environments. In particular, it will be shown how acoustic levitation, combined with optical spectroscopic instruments allows to explore a wide concentration range and to test the validity of the diameter law as a function of levitation lag time, i.e. the D2 vs t law. On this purpose a direct diameter monitoring by a video camera and a laser pointer was first performed; then the diameter was also evaluated by an indirect measure through an OH/CH band area ratio analysis of collected Raman and Infrared spectra. It clearly emerges that D2 vs t follows a linear trend for about 20 minutes, reaching then a plateau at longer time. This result shows how trehalose is able to avoid total water evaporation, this property being essential for the surviving of organisms under extreme environmental conditions.

  14. Measurement of liquid sheet using laser tagging method by photochromic dye

    Science.gov (United States)

    Rosli, Nurrina Binti; Amagai, Kenji

    2014-12-01

    Liquid atomization system has been extensively applied as the most significant process in many industrial fields. In the internal combustion engine, the combustion phenomenon is strongly influenced by the spray characteristics of the fuel given by the atomization process. In order to completely understand the whole atomization process, a detail investigation of relations between the liquid jet characteristics and the breakup phenomenon is required. In this study, a non-intrusive method called as laser tagging method by photochromic dye has been developed with aim to study the breakup process of liquid sheet in detail, covering from the behavior in film until disintegrated into ligament and droplets. The laser tagging method by photochromic dye is based on a shift in the absorption spectrum of photochromic dye molecules tagged by ultraviolet laser. The shift results a color change at the tagged region of liquid containing the dye. In this study, the motions of the dye traces were analyzed as the liquid surface velocity. As a result, liquid sheet was found to keep its velocity constantly in film before suddenly increase around broken point. However, it then decreased after broken into droplets. By forming a set of four points of dye traces on the liquid sheet, the change of relative position of the set enabled the measurement of deformation and rotational motion of the liquid sheet. As a result, the normal strain of the liquid sheet parallel to the flow direction depended on the flow behavior of ligament formation.

  15. Design and construction of liquid lasers using organic dyes

    International Nuclear Information System (INIS)

    Hariri, Akbar.

    1984-01-01

    Organic dye solution show great promise of obtaining tunable coherent light over the uv, visible and near infrared portion of spectrum. In this paper we describe various pumping schemes of dye molecules. Design, construction and performance of a pulsed dye laser, transversely pumped by a nitrogen laser and wall-ablation flash lamp-pumped dye lasers are the particular examples which are presented in detail

  16. Diffusion dynamics in micro-fluidic dye lasers

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Balslev, Søren; Mortensen, Niels Asger

    2007-01-01

    We have investigated the bleaching dynamics that occur in opto-fluidic dye lasers, where the liquid laser dye in a channel is locally bleached due to optical pumping. Our studies suggest that for micro-fluidic devices, the dye bleaching may be compensated through diffusion of dye molecules alone....... By relying on diffusion rather than convection to generate the necessary dye replenishment, our observation potentially allows for a significant simplification of opto-fluidic dye laser device layouts, omitting the need for cumbersome and costly external fluidic handling or on-chip micro-fluidic pumping...

  17. Communication: Mode bifurcation of droplet motion under stationary laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Takabatake, Fumi [Department of Physics, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Department of Bioengineering and Robotics, Graduate School of Engineering, Tohoku University, Sendai, Miyagi 980-8579 (Japan); Yoshikawa, Kenichi [Faculty of Life and Medical Sciences, Doshisha University, Kyotanabe, Kyoto 610-0394 (Japan); Ichikawa, Masatoshi, E-mail: ichi@scphys.kyoto-u.ac.jp [Department of Physics, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan)

    2014-08-07

    The self-propelled motion of a mm-sized oil droplet floating on water, induced by a local temperature gradient generated by CW laser irradiation is reported. The circular droplet exhibits two types of regular periodic motion, reciprocal and circular, around the laser spot under suitable laser power. With an increase in laser power, a mode bifurcation from rectilinear reciprocal motion to circular motion is caused. The essential aspects of this mode bifurcation are discussed in terms of spontaneous symmetry-breaking under temperature-induced interfacial instability, and are theoretically reproduced with simple coupled differential equations.

  18. Laser Techniques on Acoustically Levitated Droplets

    Directory of Open Access Journals (Sweden)

    Cannuli Antonio

    2018-01-01

    acoustically levitated droplets of trehalose aqueous solutions in order to perform spectroscopic analyses as a function of concentration and to test the theoretical diameter law. The study of such systems is important in order to better understand the behaviour of trehalose-synthesizing extremophiles that live in extreme environments. In particular, it will be shown how acoustic levitation, combined with optical spectroscopic instruments allows to explore a wide concentration range and to test the validity of the diameter law as a function of levitation lag time, i.e. the D2 vs t law. On this purpose a direct diameter monitoring by a video camera and a laser pointer was first performed; then the diameter was also evaluated by an indirect measure through an OH/CH band area ratio analysis of collected Raman and Infrared spectra. It clearly emerges that D2 vs t follows a linear trend for about 20 minutes, reaching then a plateau at longer time. This result shows how trehalose is able to avoid total water evaporation, this property being essential for the surviving of organisms under extreme environmental conditions.

  19. Photophysical and laser characteristics of pyrromethene 567 dye ...

    Indian Academy of Sciences (India)

    Narrow-band laser performance of alcohol solutions of pyrromethene 567 ... curves of each dye solution were obtained by scanning the wavelength of the dye ... solutions, using ethanol and methanol solvents, are summarized in table 1.

  20. Novel Tunable Dye Laser for Lidar Detection, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A tunable dye laser for Lidar detection will be fabricated based on the innovative dye-doped Holographic Polymer Dispersed Liquid Crystals (HPDLC) technology. The...

  1. Progress in solid state dye laser development

    Energy Technology Data Exchange (ETDEWEB)

    Hermes, R.E.

    1990-01-01

    A triaxial flashlamp (15 cm) was used to optically pump laser rods prepared from an acrylate based copolymer (0.95 cm O.D. {times} 10.0 cm L.). The performance of 13 laser dyes incorporated into this polymeric solid host is reported. The best lasing performance was obtained with sulforhodamine-B, with a calculated slope efficiency of 0.52% and a maximum single pulse output energy of 580 mJ. A commercially available fluorescent polymeric material was also evaluated. 12 refs., 2 figs.

  2. Synthesis and characterisation of new laser dyes

    International Nuclear Information System (INIS)

    Scala-Valero, Claudine

    1997-01-01

    Rhodamines are very efficient laser dyes for the red part of the visible spectrum: their fluorescence quantum efficiencies are about hundred per cent. However, their conversion efficiencies in dye amplifier are about fifty per cent, due to the presence of S n electronic level which is responsible of the re-absorption of a part of photons. In this research thesis, the author aims at trying to move this S n level out of the stimulated emission bandwidth. Models have been developed to propose new structures derived from rhodamines and theoretically possessing the desired properties. The so-recommended molecules have then been synthesised and characterised in terms of absorption and fluorescence spectra, of quantum efficiency, and of fluorescence lifetime. Two modifications are proposed for the rhodamine 6G structure, either by grafting methyl substitutes, or by grafting variously substituted amines. The searched result is obtained with the second modification [fr

  3. Laser-induced fluorescence imaging of acetone inside evaporating and burning fuel droplets

    Science.gov (United States)

    Shringi, D. S.; Shaw, B. D.; Dwyer, H. A.

    2009-01-01

    Laser-induced fluorescence was used to visualize acetone fields inside individual droplets of pure acetone as well as droplets composed of methanol or 1-propanol initially mixed with acetone. Droplets were supported on a horizontal wire and two vaporization conditions were investigated: (1) slow evaporation in room air and (2) droplet combustion, which leads to substantially faster droplet surface regression rates. Acetone was preferentially gasified, causing its concentration in droplets to drop in time with resultant decreases in acetone fluorescence intensities. Slowly vaporizing droplets did not exhibit large spatial variations of fluorescence within droplets, indicating that these droplets were relatively well mixed. Ignition of droplets led to significant variations in fluorescence intensities within droplets, indicating that these droplets were not well mixed. Ignited droplets composed of mixtures of 1-propanol and acetone showed large time-varying changes in shapes for higher acetone concentrations, suggesting that bubble formation was occurring in these droplets.

  4. Solid state microcavity dye lasers fabricated by nanoimprint lithography

    DEFF Research Database (Denmark)

    Nilsson, Daniel; Nielsen, Theodor; Kristensen, Anders

    2004-01-01

    propagating TE–TM modes. The laser cavity has the lateral shape of a trapezoid, supporting lasing modes by reflection on the vertical cavity walls. The solid polymer dye lasers emit laterally through one of the vertical cavity walls, when pumped optically through the top surface by means of a frequency...... doubled, pulsed Nd:YAG laser. Lasing in the wavelength region from 560 to 570 nm is observed from a laser with a side-length of 50 µm. In this proof of concept, the lasers are multimode with a mode wavelength separation of approximately 1.6 nm, as determined by the waveguide propagation constant......We present a solid state polymer microcavity dye laser, fabricated by thermal nanoimprint lithography (NIL) in a dye-doped thermoplast. The thermoplast poly-methylmethacrylate (PMMA) is used due to its high transparency in the visible range and its robustness to laser radiation. The laser dye...

  5. Droplet-Assisted Laser Direct Nanoscale Writing on Silicon

    Directory of Open Access Journals (Sweden)

    Yuan-Jen Chang

    2016-03-01

    Full Text Available Nano-structuring using laser direct writing technology has shown great potential for industrial applications. A novel application of water droplets to this technology is proposed in this paper. With a hydrophobic layer and a controlled substrate temperature, a layer of randomly distributed water droplets with a high contact angle is formed on the substrate. These liquid droplets can be used as lenses to enhance the laser intensity at the bottom of the droplets. As a result, nanoscale holes can be fabricated on the substrate by controlling the laser energy density. We successfully fabricated holes with a diameter of 600 nm at a substrate temperature of 12 ∘C and a power density of 1.2 × 108 W/cm2 in our experiments. We also found that the hole diameter was around a ninth of the water droplet diameter. Meanwhile, the machined holes are not affected much by the focal length of the lens, but a hole with less than 100 nm in diameter at the center was observed.

  6. Enhancement of polymer dye lasers by multifunctional photonic crystal lattice

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Xiao, Sanshui; Mortensen, Asger

    2009-01-01

    The light output of dye doped hybrid polymer band-edge lasers is increased more than 100 times by using a rectangular lattice photonic crystal, which provides both feedback and couples more pump light into the laser.......The light output of dye doped hybrid polymer band-edge lasers is increased more than 100 times by using a rectangular lattice photonic crystal, which provides both feedback and couples more pump light into the laser....

  7. Superthin resonator dye laser with THz intermode frequency separation

    International Nuclear Information System (INIS)

    Rudych, P D; Surovtsev, N V

    2014-01-01

    Two-color laser irradiation is considered an effective way to pump THz excitations for numerous scientific and applied goals. We present a design for convenient laser source with THz intermode frequency separation. The setup is based on dye laser with superthin resonator pumped by a subnanosecond pulse laser. It was proven that the superthin resonator dye laser is useful, possesses high stability and high energy conversion, and generates narrow laser modes. The ability of this laser to pump CARS processes for THz vibrations is demonstrated. (letter)

  8. High intensity laser interactions with sub-micron droplets

    International Nuclear Information System (INIS)

    Mountford, L.C.

    1999-01-01

    A high-density source of liquid ethanol droplets has been developed, characterised and used in laser interaction studies for the first time. Mie Scattering and attenuation measurements show that droplets with a radius of (0.5 ± 0.1) μm and atomic densities of 10 19 atoms/cm 3 can be produced, bridging the gap between clusters and macroscopic solids. Lower density (10 16 cm -3 ) sprays can also be produced and these are electrostatically split into smaller droplets with a radius of (0.3 ± 0.1) μm. This work has been accepted for publication in Review of Scientific Instruments. A range of high intensity interaction experiments have been carried out with this unique sub-micron source. The absolute yield of keV x-rays, generated using 527 nm, 2 ps pulses focused to ∼10 17 W/cm 2 , was measured for the first time. ∼7 μJ of x-rays with photon energies above 1 keV were produced, comparable to yields obtained from much higher Z Xenon clusters. At intensities ≤10 16 W/cm 2 the yield from droplets exceeds that from solid targets of similar Z. The droplet medium is debris free and self-renewing, providing a suitable x-ray source for lithographic techniques. Due to the spacing between the droplets, it was expected that the droplet plasma temperature would exceed that of a solid target plasma, which is typically limited by rapid heat conduction to <1 keV. Analysis of the x-ray data shows this to be true with a mean droplet plasma temperature of (2 ± 0.8) keV, and a number of measurements exceeding 5 keV (to appear in Applied Physics Letters). The absorption of high intensity laser pulses in the dense spray has been measured for the first time and this was found to be wavelength and polarisation independent and in excess of 60%. These first interaction measurements clearly indicate that there are significant differences between the laser heating of droplet, solid and cluster targets. (author)

  9. Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction

    Science.gov (United States)

    Fritz, Bradley K.; Hoffmann, W. Clint

    2016-01-01

    When making an application of any crop protection material such as an herbicide or pesticide, the applicator uses a variety of skills and information to make an application so that the material reaches the target site (i.e., plant). Information critical in this process is the droplet size that a particular spray nozzle, spray pressure, and spray solution combination generates, as droplet size greatly influences product efficacy and how the spray moves through the environment. Researchers and product manufacturers commonly use laser diffraction equipment to measure the spray droplet size in laboratory wind tunnels. The work presented here describes methods used in making spray droplet size measurements with laser diffraction equipment for both ground and aerial application scenarios that can be used to ensure inter- and intra-laboratory precision while minimizing sampling bias associated with laser diffraction systems. Maintaining critical measurement distances and concurrent airflow throughout the testing process is key to this precision. Real time data quality analysis is also critical to preventing excess variation in the data or extraneous inclusion of erroneous data. Some limitations of this method include atypical spray nozzles, spray solutions or application conditions that result in spray streams that do not fully atomize within the measurement distances discussed. Successful adaption of this method can provide a highly efficient method for evaluation of the performance of agrochemical spray application nozzles under a variety of operational settings. Also discussed are potential experimental design considerations that can be included to enhance functionality of the data collected. PMID:27684589

  10. Threshold pump power of a solar-pumped dye laser

    Science.gov (United States)

    Lee, Ja H.; Kim, Kyung C.; Kim, Kyong H.

    1988-01-01

    Threshold solar power for dye laser pumping has been determined by measuring the gain of a rhodamine 6G dye laser amplifier at various solar-simulated irradiances on an amplifier cell. The measured threshold was 20,000 solar constants (2.7 kW/sq cm) for the dye volume of 2 x 5 x 40 cu mm and the optimum dye concentration of 0.001 M. The threshold is about one-third of that achievable with a high-intensity solar concentrator.

  11. Distributed feedback dye laser pumped with copper-vapor laser emission

    Energy Technology Data Exchange (ETDEWEB)

    Mirza, S Yu; Soldatov, A N; Sukhanov, V B

    1983-10-01

    The power-spectrum characteristics of the emission of a distributed feedback dye laser pumped with a copper vapor laser have been studied. Laser action has been observed in five dyes over a tuning range of 530-723 nm with an efficiency of 12.4%. The specfic features of the distributed feedback dye laser operating at pulse repetition rates of 4 kHz are discussed.

  12. High-power single-mode cw dye ring laser

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, H W; Stein, L; Froelich, D; Fugger, B; Welling, H [Technische Univ. Hannover (Germany, F.R.). Inst. fuer Angewandte Physik

    1977-12-01

    Due to spatial hole burning, standing-wave dye lasers require a large amount of selectivity inside the cavity for single-mode operation. The output power of these lasers is limited by losses caused by the frequency selecting elements. In a travelling-wave laser, on the other hand, spatial hole burning does not exist, thereby eliminating the need for high selectivity. A travelling-wave cw dye laser was realized by unidirectional operation of a ring laser, yielding single mode output powers of 1.2 W at 595 nm and of 55 mW in the UV-region with intracavity frequency doubling.

  13. Photoactive dye-enhanced tissue ablation for endoscopic laser prostatectomy.

    Science.gov (United States)

    Ahn, Minwoo; Hau, Nguyen Trung; Van Phuc, Nguyen; Oh, Junghwan; Kang, Hyun Wook

    2014-11-01

    Laser light has been widely used as a surgical tool to treat benign prostate hyperplasia (BPH) over 20 years. Recently, application of high laser power up to 200 W was often reported to swiftly remove a large amount of prostatic tissue. The purpose of this study was to validate the feasibility of photoactive dye injection to enhance light absorption and eventually to facilitate tissue vaporization with low laser power. Chicken breast tissue was selected as a target tissue due to minimal optical absorption at the visible wavelength. Four biocompatible photoactive dyes, including amaranth (AR), black dye (BD), hemoglobin powder (HP), and endoscopic marker (EM), were selected and tested in vitro with a customized 532 nm laser system with radiant exposure ranging from 0.9 to 3.9 J/cm(2) . Light absorbance and ablation threshold were measured with UV-Vis spectrometer and Probit analysis, respectively, and compared to feature the function of the injected dyes. Ablation performance with dye-injection was evaluated in light of radiant exposure, dye concentration, and number of injection. Higher light absorption by injected dyes led to lower ablation threshold as well as more efficient tissue removal in the order of AR, BD, HP, and EM. Regardless of the injected dyes, ablation efficiency principally increased with radiant exposure, dye concentration, and number of injection. Among the dyes, AR created the highest ablation rate of 44.2 ± 0.2 µm/pulse due to higher absorbance and lower ablation threshold. High aspect ratios up to 7.1 ± 0.4 entailed saturation behavior in the tissue ablation injected with AR and BD, possibly resulting from plume shielding and increased scattering due to coagulation. Preliminary tests on canine prostate with a hydraulic injection system demonstrated that 80 W with dye injection yielded comparable ablation efficiency to 120 W with no injection, indicating 33% reduced laser power with almost equivalent performance. Due to

  14. Photoactive dye enhanced tissue ablation for endoscopic laser prostatectomy

    Science.gov (United States)

    Ahn, Minwoo; Nguyen, Trung Hau; Nguyen, Van Phuc; Oh, Junghwan; Kang, Hyun Wook

    2015-02-01

    Laser light has been widely used as a surgical tool to treat benign prostate hyperplasia with high laser power. The purpose of this study was to validate the feasibility of photoactive dye injection to enhance light absorption and eventually to facilitate tissue ablation with low laser power. The experiment was implemented on chicken breast due to minimal optical absorption Amaranth (AR), black dye (BD), hemoglobin powder (HP), and endoscopic marker (EM), were selected and tested in vitro with a customized 532-nm laser system with radiant exposure ranging from 0.9 to 3.9 J/cm2. Light absorbance and ablation threshold were measured with UV-VIS spectrometer and Probit analysis, respectively, and compared to feature the function of the injected dyes. Ablation performance with dye-injection was evaluated in light of radiant exposure, dye concentration, and number of injection. Higher light absorption by injected dyes led to lower ablation threshold as well as more efficient tissue removal in the order of AR, BD, HP, and EM. Regardless of the injected dyes, ablation efficiency principally increased with input parameter. Among the dyes, AR created the highest ablation rate of 44.2+/-0.2 μm/pulse due to higher absorbance and lower ablation threshold. Preliminary tests on canine prostate with a hydraulic injection system demonstrated that 80 W with dye injection yielded comparable ablation efficiency to 120 W with no injection, indicating 33 % reduced laser power with almost equivalent performance. In-depth comprehension on photoactive dye-enhanced tissue ablation can help accomplish efficient and safe laser treatment for BPH with low power application.

  15. A replacement solvent for dimethylsulfoxide /DMSO/ in CW dye lasers

    Energy Technology Data Exchange (ETDEWEB)

    Herbelin, J.M.; McKay, J.A.

    1981-01-01

    The use of propylene glycol carbonate as a replacement solvent for dimethyl sulfoxide in a Coherent model 599-21 CW dye laser has been investigated. Up to 40 milliwatts of single frequency output was achieved at 875 nm.

  16. Frequency doubled dye laser with a servo-tuned crystal

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, J; Spitschan, H

    1975-01-01

    Spectral tuning of the uv output of a frequency doubled dye laser was successfully controlled by a servo motor system which tilts the nonlinear crystal appropriate for phase-matched second harmonic generation while the dye laser emission wavelength is tuned. The spatial direction of the generated uv beam was used as the regulating signal. The feasibility of this technique for spectroscopic applications was successfully tested.

  17. Analysis of photoisomerizable dyes using laser absorption and fluorescence techniques

    International Nuclear Information System (INIS)

    Duchowicz, R.; Di Paolo, R.E.; Scaffardi, L.; Tocho, J.O.

    1992-01-01

    The attention of the present report has been directed mainly to the description of laser-based techniques developed in order to obtain kinetic and spectroscopic properties of polymethine cyanine dyes in solution. Special attention was dedicated to photoisomerizable molecules where the absorption spectra of both isomers are strongly overlapped. As an example, measurements of two different dyes of laser technological interest, DTCI and DODCI were performed. The developed methods provide a complete quantitative description of photophysical processes. (author). 14 refs, 6 figs

  18. Investigation of rf plasma light sources for dye laser excitation

    International Nuclear Information System (INIS)

    Kendall, J.S.; Jaminet, J.F.

    1975-06-01

    Analytical and experimental studies were performed to assess the applicability of radio frequency (rf) induction heated plasma light sources for potential excitation of continuous dye lasers. Experimental efforts were directed toward development of a continuous light source having spectral flux and emission characteristics approaching that required for pumping organic dye lasers. Analytical studies were performed to investigate (1) methods of pulsing the light source to obtain higher radiant intensity and (2) methods of integrating the source with a reflective cavity for pumping a dye cell. (TFD)

  19. Investigation of dye laser excitation of atomic systems

    International Nuclear Information System (INIS)

    Abate, J.A.

    1977-01-01

    A stabilized cw dye laser system and an optical pumping scheme for a sodium atomic beam were developed, and the improvements over previously existing systems are discussed. A method to stabilize both the output intensity and the frequency of the cw dye laser for periods of several hours is described. The fluctuation properties of this laser are investigated by photon counting and two-time correlation measurements. The results show significant departures from the usual single-mode laser theory in the region of threshold and below. The implications of the deviation from accepted theory are discussed. The atomic beam system that was constructed and tested is described. A method of preparing atomic sodium so that it behaves as a simple two-level atom is outlined, and the results of some experiments to study the resonant interaction between the atoms and the dye laser beam are presented

  20. Development of frequency tunable Ti:sapphire laser and dye laser pumped by a pulsed Nd:YAG laser

    International Nuclear Information System (INIS)

    Yi, Jong Hoon; Horn, Roland; Wendt, K.

    2001-01-01

    We investigated lasing characteristics of two kinds of tunable laser, liquid dye laser and solid Ti:sapphire crystal laser, pumped by high pulse repetition rate Nd:YAG laser. Dye laser showed drastically reduced pulsewidth compared with that of pump laser and it also contained large amount of amplified spontaneous emission. Ti:sapphire laser showed also reduced pulsewidth. But, the laser conversion pump laser and Ti:sapphire laser pulse, we used a Brewster-cut Pockel's cell for Q-switching. The laser was frequency doubled by a type I BBO crystal outside of the cavity.

  1. Dye laser spectrometer for the analysis of pulsed vacuum arcs

    International Nuclear Information System (INIS)

    Hargis, P.J. Jr.; Robertson, M.M.

    1975-01-01

    A pulsed dye laser spectrometer which is used to obtain detailed single shot spectroscopic measurements of the plasma in a pulsed vacuum arc was developed. The capabilities of this spectrometer are indicated by the detection of laser induced fluorescence signals from 10 6 neutral Ti atoms in the plasma of a pulsed vacuum arc with a Ti anode. (U.S.)

  2. Tunable dye laser research at U. N. E

    Energy Technology Data Exchange (ETDEWEB)

    Haydon, S C

    1976-10-01

    Attempts to extend present tunable radiation sources into the wavelength region from 140 to 330 nm are presented in the following areas: frequency doubling and parametric upconversion methods, frequency mixing techniques in metal vapors, the pulsed N/sub 2/ laser, tunable dye lasers for the near uv to ir spectral range, heat pipe ovens, and preliminary experiments. (MHR)

  3. Development of high-power dye laser chain

    Science.gov (United States)

    Konagai, Chikara; Kimura, Hironobu; Fukasawa, Teruichiro; Seki, Eiji; Abe, Motohisa; Mori, Hideo

    2000-01-01

    Copper vapor laser (CVL) pumped dye laser (DL) system, both in a master oscillator power amplifier (MOPA) configuration, has been developed for Atomic Vapor Isotope Separation program in Japan. Dye laser output power of about 500 W has been proved in long-term operations over 200 hours. High power fiber optic delivery system is utilized in order to efficiently transport kilowatt level CVL beams to the DL MOPA. Single model CVL pumped DL oscillator has been developed and worked for 200 hours within +/- 0.1 pm wavelength stability. Phase modulator for spreading spectrum to the linewidth of hyperfine structure has been developed and demonstrated.

  4. Laser-induced micro-jetting from armored droplets

    KAUST Repository

    Marston, J. O.

    2015-06-23

    We present findings from an experimental study of laser-induced cavitation within a liquid drop coated with a granular material, commonly referred to as “armored droplets” or “liquid marbles.” The cavitation event follows the formation of plasma after a nanosecond laser pulse. Using ultra-high-speed imaging up to 320,610 fps, we investigate the extremely rapid dynamics following the cavitation, which manifests itself in the form of a plethora of micro-jets emanating simultaneously from the spaces between particles on the surface of the drop. These fine jets break up into droplets with a relatively narrow diameter range, on the order of 10 μm. © 2015, Springer-Verlag Berlin Heidelberg.

  5. Bibliographic study of photophysical and photochemical properties of laser dyes

    International Nuclear Information System (INIS)

    Doizi, D.

    1986-06-01

    Laser isotope separation of uranium requires high power and precise wave length. This report is a bibliographic and experimental study of the photophysical and photochemical properties of seven commercial laser dyes which have an emission wavelength in the range 5500-6500 A: Rhodamine 110 or 560, rhodamine 6G or 590, rhodamine B or 610, rhodamine 101 or 640, sulforhodamine B or kiton red 620, sulforhodamine 101 or 640 and DCM or LC 6500. Absorption and emission cross section values, fluorescence lifetimes and quantum yields in various solvents are indicated. For each dye, a non exhaustive list of laboratory experiments made with two types of pump sources: Nd YAG (532) and copper vapor laser is given. When it is known, the toxicity of the dyes is mentioned [fr

  6. Lasing of Some Red Laser Dyes in Annealed Silica Xerogel

    Science.gov (United States)

    Bezkrovnaya, O. N.; Maslov, V. V.; Pritula, I. M.; Yurkevich, A. G.

    2018-01-01

    The spectral and energy characteristics of generation in the red spectral region 650-720 nm were measured and analyzed for three laser dyes in preliminarily annealed SiO2 xerogel matrices under laser excitation λp = 588 nm in a nonselective cavity. The specific laser-energy output for two of them (LK678 and Ox170) in the matrices was 10-13% higher than in MeOH. NBA dye in the matrix generated two laser radiation bands in the 700-720 nm region with pumping E p ≥ 80 mJ whereas its generation threshold in MeOH exceeded the maximum pumping energy of 140 mJ so that NBA generation was not observed. Laser emission spectra of the studied matrices in a nonselective cavity were red-shifted by 1000 cm-1 from the fluorescence maximum. Such a shift could improve the characteristics of biosensors based on these matrices.

  7. An application of the theory of laser to nitrogen laser pumped dye laser

    International Nuclear Information System (INIS)

    Osman, Fatima Ahmed

    1998-03-01

    In this thesis we gave a general discussion on lasers, reviewing some of their properties, types and application. We also conducted an experiment where we obtained a dye laser pumped by nitrogen laser with a wave length of 337.1 nm and a power of 5 Mw.It was noticed that the produced radiation possesses characteristics different from those of other types of laser. This characteristics determine the tunability i.e the possibility of choosing the appropriately required wave-length of radiation for various applications.(Author)

  8. OH spectroscopy with frequency-doubled dye laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    ter Meulen, J J

    1979-01-01

    Discusses the excitation of the OH radical by UV radiation for the determination of the hyperfine structure of the excited states. The 307 nm UV light is obtained by doubling the frequency (in double-refraction crystals) of a tunable dye laser. Details of the laser set-up are given. The method is suitable for application to other high-resolution molecular spectroscopy experiments in the area between 200 and 400 nm. Further extensions can be expected with ring compound dyes and external doubling of the frequency.

  9. Molecular dynamics stimulations to study laser dye aggregation in water (comparison with experiments)

    International Nuclear Information System (INIS)

    Dare-Doyen, St.; Doizi, D.

    2000-01-01

    A laser facility consists of dye laser chains where the active medium is composed of fluorescent dyes dissolved in ethanol. The use of water as a solvent would offer two major advantages: greater safety of the laser facility by drastically reducing fire risks, easier design of the laser beam correcting devices required at the end of the dye laser chains, thanks to the properties of water. Unfortunately, laser dyes exhibit poor optical properties in water, due to the formation of dye aggregates. Molecular dynamics simulations were used to study and develop means to prevent this behavior between two charged species. The results were compared with NMR (Nuclear Magnetic Resonance) experiments

  10. Solvent effects on lasing characteristics for Rh B laser dye

    Energy Technology Data Exchange (ETDEWEB)

    Peter, Jaison, E-mail: jaison.peter@gmail.com [International School of Photonics, Cochin University of Science and Technology, Cochin 682022 (India); Kumar, Mahesh [Department of Applied Chemistry, Cochin University of Science and Technology, Cochin 682022 (India); Ananad, V.R.; Saleem, Rasool; Sebastian, Ananthu; Radhakrishnan, P.; Nampoori, V.P.N.; Vallabhan, C.P.G. [International School of Photonics, Cochin University of Science and Technology, Cochin 682022 (India); Prabhu, Radhakrishna [School of Engineering, Robert Gordon University, Aberdeen AB10 1FR, Scotland (United Kingdom); Kailasnath, M. [International School of Photonics, Cochin University of Science and Technology, Cochin 682022 (India)

    2016-01-15

    We demonstrate pulsed, photopumped multimode laser emission in the visible spectral range from rhodamine B dye dissolved in various solvents. The laser emission is characterized by a well-defined, low threshold pump power at which the emission spectral intensity dramatically increases and collapsed into several dominant laser modes with reduced mode spacing and spectral width. The modes were found to originate from the subcavities formed by the plane-parallel walls of the cuvette containing the gain medium. The cavity lasing spectral structure and the numbers of longitudinal modes were easily controlled by changing the solvents. A shift in the emission spectra has been also observed by changing the solvents will allow a limited range of tuning of laser emission wavelength. We also determined the gain coefficient and stimulated emission cross-section for the Rh B dye dissolved liquid laser system. A detailed discussion of the solvent effect in the lasing characteristics of Rh B in different solution is explained along with the computational data. - Highlights: • Report multimode laser emission from rhodamine B dye dissolved in various solvents. • Modes are originated from the plane-parallel walls of the cuvette. • Spectral range and the number of modes can be controlled by changing the solvents. • Changing solvents also allows a limited range of tuning of laser emission.

  11. Active-passively mode-locked dye laser for diagnosis of laser-produced plasmas

    International Nuclear Information System (INIS)

    Teng, Y.L.; Fedosejevs, R.; Sigel, R.

    1981-03-01

    In this report an active-passively mode-locked, flashlamp-pumped dye laser for diagnosis of laser-produced plasmas is described. This dye laser system used as a pulsed light source for high-speed photography of laser-target experiments was synchronized to the ASTERIX III iodine laser pulse with better than 100 ps accuracy. The single pulse energy was 10 μJ, pulse duration less than 10 ps. In 111 shots clear shadowgrams were obtained during a total of 151 target shots, i.e. the system worked well in 74% of the shots. (orig.)

  12. Tunable lasers in isotope separation, a colorful view of a dye chemist

    International Nuclear Information System (INIS)

    Hammond, P.R.

    1976-01-01

    Some of the problems to be encountered in the large-scale use of dye lasers in an isotope separation plant are discussed. Why should dye lasers be employed. How can dye conversion efficiency be optimized. How can dye photochemical decomposition and hence running costs be minimized and how serious is this effect anyway. What are toxicity problems with the dye. These and similar issues are examined

  13. Dye laser light for high-resolution classical photography

    International Nuclear Information System (INIS)

    Geissler, K.K.

    1982-01-01

    The test run with the bubble chamber HOLEBC in October 1981 offered the opportunity of checking the usefulness of de-speckled dye laser light for illumination purposes in high-resolution classical dark field photography of small bubble chambers. (orig./HSI)

  14. In liquid laser treated graphene oxide for dye removal

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paola, E-mail: rsspla1@gmail.com [Dipartimento di Scienze Chimiche, Universita’ degli Studi di Catania, Viale Andrea Doria 6, Catania 95125 (Italy); Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Ave., West Waterloo, Ontario N2L 3G1 (Canada); D’Urso, Luisa [Dipartimento di Scienze Chimiche, Universita’ degli Studi di Catania, Viale Andrea Doria 6, Catania 95125 (Italy); Hu, Anming [Department of Mechanical, Aerospace and Biomedical Engineering, University of Tennessee, Knoxville, TN 57996-2210 (United States); Zhou, Norman [Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Ave., West Waterloo, Ontario N2L 3G1 (Canada); Compagnini, Giuseppe [Dipartimento di Scienze Chimiche, Universita’ degli Studi di Catania, Viale Andrea Doria 6, Catania 95125 (Italy)

    2015-09-01

    Highlights: • Graphene oxide and reduced graphene oxide were tested as adsorbents for dye removal from water. • Reduced graphene oxide was obtained after laser irradiation of a colloidal suspension of graphene oxide. • Methylene blue was chosen as the dye to test graphene oxide and reduced graphene oxide. - Abstract: The presence of dyes, pharmaceuticals and many other pollutants in wastewaters is critical due to severe effects on the human beings and on the environment. Here, solutions of graphene oxide (GO) and reduced graphene oxide (rGO) were tested as adsorbents for the removal of methylene blue (MB), a cationic dye, from aqueous media. The reduced forms of graphene oxide were obtained after laser irradiation of colloidal suspensions of graphene oxide, obtained by the Hummers and Offeman's method. We observed that both graphene oxide and its reduced forms are excellent adsorbents towards methylene blue. In particular, rGO showed a higher adsorption capacity than GO, suggesting that a strict control of laser irradiation time permits to obtain rGO with different degrees of reduction and therefore the residual oxygenated functional groups may influence the adsorption behaviour more or less. Characterization of the samples by atomic force microscopy (AFM) showed that produced rGO sheets via laser irradiation exhibited a discontinuous surface where some holes could be detected contributing to an enhancement of the rGO surface area that is a higher adsorption capacity.

  15. Ultraviolet-pumped liquid-crystal dye-laser

    International Nuclear Information System (INIS)

    Bertolotti, M.; Sbrolli, L.; Scudieri, F.; Papa, T.

    1981-01-01

    The possibility offered by the orientation properties of liquid crystals as a matrix for dye lasers is shown. In particular, the linear polarization of emitted light can be changed by acting with an external magnetic field on the molecular nematic director. (author)

  16. Polymer photonic crystal dye lasers as optofluidic cell sensors

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Lopacinska, Joanna M.; Jakobsen, Mogens Havsteen

    2009-01-01

    Dye doped hybrid polymer lasers are implemented as label free evanescent field biosensors for detection of cells. It is demonstrated that although the coverage is irregular and the cells extend over several lattice constants, the emission wavelength depends linearly on the fraction of the surface...

  17. Diffusion driven optofluidic dye lasers encapsulated into polymer chips

    DEFF Research Database (Denmark)

    Wienhold, Tobias; Breithaupt, Felix; Vannahme, Christoph

    2012-01-01

    Lab-on-a-chip systems made of polymers are promising for the integration of active optical elements, enabling e.g. on-chip excitation of fluorescent markers or spectroscopy. In this work we present diffusion operation of tunable optofluidic dye lasers in a polymer foil. We demonstrate that these ......Lab-on-a-chip systems made of polymers are promising for the integration of active optical elements, enabling e.g. on-chip excitation of fluorescent markers or spectroscopy. In this work we present diffusion operation of tunable optofluidic dye lasers in a polymer foil. We demonstrate...... that these first order distributed feedback lasers can be operated for more than 90 min at a pulse repetition rate of 2 Hz without fluidic pumping. Ultra-high output pulse energies of more than 10 μJ and laser thresholds of 2 μJ are achieved for resonator lengths of 3 mm. By introducing comparatively large on......-chip dye solution reservoirs, the required exchange of dye molecules is accomplished solely by diffusion. Polymer chips the size of a microscope cover slip (18 × 18 mm2) were fabricated in batches on a wafer using a commercially available polymer (TOPAS® Cyclic Olefin Copolymer). Thermal imprinting...

  18. Characteristics of Droplets Ejected from Liquid Propellants Ablated by Laser Pulses in Laser Plasma Propulsion

    International Nuclear Information System (INIS)

    Zheng Zhiyuan; Gao Hua; Fan Zhenjun; Xing Jie

    2014-01-01

    The angular distribution and pressure force of droplets ejected from liquid water and glycerol ablated by nanosecond laser pulses are investigated under different viscosities in laser plasma propulsion. It is shown that with increasing viscosity, the distribution angles present a decrease tendency for two liquids, and the angular distribution of glycerol is smaller than that of water. A smaller distribution leads to a higher pressure force generation. The results indicate that ablation can be controlled by varying the viscosity of liquid propellant in laser plasma propulsion

  19. Interferometric laser imaging for in-flight cloud droplet sizing

    International Nuclear Information System (INIS)

    Dunker, Christina; Roloff, Christoph; Grassmann, Arne

    2016-01-01

    A non-intrusive particle sizing method with a high spatial distribution is used to estimate cloud droplet spectra during flight test campaigns. The interferometric laser imaging for droplet sizing (ILIDS) method derives particle diameters of transparent spheres by evaluating the out-of-focus image patterns. This sizing approach requires a polarized monochromatic light source, a camera including an objective lens with a slit aperture, a synchronization unit and a processing tool for data evaluation. These components are adapted to a flight test environment to enable the microphysical investigation of different cloud genera. The present work addresses the design and specifications of ILIDS system, flight test preparation and selected results obtained in the lower and middle troposphere. The research platform was a Dornier Do228-101 commuter aircraft at the DLR Flight Operation Center in Braunschweig. It was equipped with the required instrumentation including a high-energy laser as the light source. A comprehensive data set of around 71 800 ILIDS images was acquired over the course of five flights. The data evaluation of the characteristic ILIDS fringe patterns relies, among other things, on a relationship between the fringe spacing and the diameter of the particle. The simplest way to extract this information from a pattern is by fringe counting, which is not viable for such an extensive number of data. A brief contrasting comparison of evaluation methods based on frequency analysis by means of fast Fourier transform and on correlation methods such as minimum quadratic difference is used to encompass the limits and accuracy of the ILIDS method for such applications. (paper)

  20. Investigation of the dye concentration influence on the lasing wavelength and threshold for a micro-fluidic dye laser

    DEFF Research Database (Denmark)

    Helbo, Bjarne; Kragh, Søren; Kjeldsen, B.G.

    2003-01-01

    We investigate a micro-fluidic dye laser, which can be integrated with polymer-based lab-on-a-chip microsystems without further processing steps. A simple rate-equation model is used to predict the lasing threshold. The laser device is characterised using the laser dye Rhodamine 6G dissolved...... in ethanol, and the influence of dye concentration on the lasing wavelength and threshold is investigated. The experiments confirm the predictions of the rate-equation model, that lasing can be achieved in the 10 mum long laser cavity with moderate concentrations of Rhodamine 6G in ethanol, starting from 5 x...

  1. Dye-enhanced laser welding for skin closure.

    Science.gov (United States)

    DeCoste, S D; Farinelli, W; Flotte, T; Anderson, R R

    1992-01-01

    The use of a laser to weld tissue in combination with a topical photosensitizing dye permits selective delivery of energy to the target tissue. A combination of indocyanine green (IG), absorption peak 780 nm, and the near-infrared (IR) alexandrite laser was studied with albino guinea pig skin. IG was shown to bind to the outer 25 microns of guinea pig dermis and appeared to be bound to collagen. The optical transmittance of full-thickness guinea pig skin in the near IR was 40% indicating that the alexandrite laser should provide adequate tissue penetration. Laser "welding" of skin in vivo was achieved at various concentrations of IG from 0.03 to 3 mg/cc using the alexandrite at 780 nm, 250-microseconds pulse duration, 8 Hz, and a 4-mm spot size. A spectrum of welds was obtained from 1- to 20-W/cm2 average irradiance. Weak welds occurred with no thermal damage obtained at lower irradiances: stronger welds with thermal damage confined to the weld site occurred at higher irradiances. At still higher irradiances, local vaporization occurred with failure to "weld." Thus, there was an optimal range of irradiances for "welding," which varied inversely with dye concentration. Histology confirmed the thermal damage results that were evident clinically. IG dye-enhanced laser welding is possible in skin and with further optimization may have practical application.

  2. Dye-enhanced diode laser photocoagulation of choroidal neovascularizations

    Science.gov (United States)

    Klingbeil, Ulrich; Puliafito, Carmen A.; McCarthy, Dan; Reichel, Elias; Olk, Joseph; Lesiecki, Michael L.

    1994-06-01

    Dye-enhanced diode laser photocoagulation, using the dye indocyanine green (ICG), has shown some potential in the treatment of choroidal neovascularizations (CNV). A diode laser system was developed and optimized to emit at the absorption maximum of ICG. In a clinical study at two retinal centers, more than 70 patients, the majority of which had age-related macular degeneration, were treated. Eighteen cases with ill-defined subfoveal CNV were followed an average of 11 months after laser treatment. The results show success in resolving the CNV with an average long-term preservation of visual function equal to or superior to data provided by the Macular Photocoagulation Study for confluent burns of low intensity applied to the CNV. Details of the technique and discussion of the controversies inherent in such a treatment strategy will be presented.

  3. Laser-induced superhydrophobic grid patterns on PDMS for droplet arrays formation

    Energy Technology Data Exchange (ETDEWEB)

    Farshchian, Bahador [Ingram School of Engineering, Texas State University, San Marcos, TX 78666 (United States); Gatabi, Javad R. [Materials Science, Engineering and Commercialization, Texas State University, San Marcos, TX 78666 (United States); Bernick, Steven M.; Park, Sooyeon [Ingram School of Engineering, Texas State University, San Marcos, TX 78666 (United States); Lee, Gwan-Hyoung [Department of Materials Science and Engineering, Yonsei University, Seoul 03722 (Korea, Republic of); Droopad, Ravindranath [Ingram School of Engineering, Texas State University, San Marcos, TX 78666 (United States); Materials Science, Engineering and Commercialization, Texas State University, San Marcos, TX 78666 (United States); Kim, Namwon, E-mail: n_k43@txstate.edu [Ingram School of Engineering, Texas State University, San Marcos, TX 78666 (United States)

    2017-02-28

    Highlights: • Superhydrophobic grid patterns were processed on the surface of PDMS using a pulsed nanosecond laser. • Droplet arrays form instantly on the laser-patterned PDMS with the superhydrophobic grid pattern when the PDMS sample is simply immersed in and withdrawn from water. • Droplet size can be controlled by controlling the pitch size of superhydrophobic grid and the withdrawal speed. - Abstract: We demonstrate a facile single step laser treatment process to render a polydimethylsiloxane (PDMS) surface superhydrophobic. By synchronizing a pulsed nanosecond laser source with a motorized stage, superhydrophobic grid patterns were written on the surface of PDMS. Hierarchical micro and nanostructures were formed in the irradiated areas while non-irradiated areas were covered by nanostructures due to deposition of ablated particles. Arrays of droplets form spontaneously on the laser-patterned PDMS with superhydrophobic grid pattern when the PDMS sample is simply immersed in and withdrawn from water due to different wetting properties of the irradiated and non-irradiated areas. The effects of withdrawal speed and pitch size of superhydrophobic grid on the size of formed droplets were investigated experimentally. The droplet size increases initially with increasing the withdrawal speed and then does not change significantly beyond certain points. Moreover, larger droplets are formed by increasing the pitch size of the superhydrophobic grid. The droplet arrays formed on the laser-patterned PDMS with wettability contrast can be used potentially for patterning of particles, chemicals, and bio-molecules and also for cell screening applications.

  4. Single mode dye-doped polymer photonic crystal lasers

    International Nuclear Information System (INIS)

    Christiansen, Mads B; Buß, Thomas; Smith, Cameron L C; Petersen, Sidsel R; Jørgensen, Mette M; Kristensen, Anders

    2010-01-01

    Dye-doped polymer photonic crystal (PhC) lasers fabricated by combined nanoimprint and photolithography are studied for their reproducibility and stability characteristics. We introduce a phase shift in the PhC lattice that substantially improves the yield of single wavelength emission. Single mode emission and reproducibility of laser characteristics are important if the lasers are to be mass produced in, e.g., optofluidic sensor chips. The fabrication yield is above 85% with highly reproducible wavelengths (within 0.5%), and the temperature dependence on the wavelength is found to be −0.045 or −0.066 nm K -1 , depending on the material

  5. Single mode dye-doped polymer photonic crystal lasers

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Buss, Thomas; Smith, Cameron

    2010-01-01

    Dye-doped polymer photonic crystal (PhC) lasers fabricated by combined nanoimprint and photolithography are studied for their reproducibility and stability characteristics. We introduce a phase shift in the PhC lattice that substantially improves the yield of single wavelength emission. Single mode...... emission and reproducibility of laser characteristics are important if the lasers are to be mass produced in, e. g., optofluidic sensor chips. The fabrication yield is above 85% with highly reproducible wavelengths (within 0.5%), and the temperature dependence on the wavelength is found to be -0.045 or -0...

  6. Solid-state polymeric dye lasers

    CERN Document Server

    Singh, S; Sridhar, G; Muthuswamy, V; Raja, K

    2003-01-01

    This paper presents a review of the organic solid-state polymer materials, which have become established as a new laser media. The photostability of these materials is discussed. Different types of solid-state lasers built around these materials are also reviewed.

  7. Development of tunable flashlamp excited dye laser system

    International Nuclear Information System (INIS)

    Bhanthumnavin, V.; Apikitmata, S.; Kochareon, P.

    1991-01-01

    A tunable flashlamp excited dye laser (FEDL) was successfully developed for the first time in Thailand by Thai scientists at KMIT Thonburi (Bangmod). The Rhodamine 6G dissolved in ethyl alcohol was utilized as a laser medium and circulated by a pump through a laser head. The dye cuvette had an inner diameter of 4.0 mm and was 90 mm long. The cavity mirrors M 1 , and M 2 were concave mirrors with reflectivities of 100% and 73% respectively. A power supply of 0-20 kV and current of 0-50 mA charged a capacitor of 0.3 μ f at 10-15 kV which was then discharged via a spark gap through the flashlamp. The output laser wavelengths was tunable from λ = 550-640 nm. It is the first FEDL system, locally developed, which has a tunable wavelength for the laser output. The laser pulse width is about 1.0 μs with energy of 20 mJ and peak power pf 20 KW. The repetition rate of the laser is 1/15 Hz. (author). 14 refs, 7 figs

  8. Studies on widely tunable ultra-short laser pulses using energy transfer distributed feedback dye laser

    International Nuclear Information System (INIS)

    Ahamed, M.B.; Ramalingam, A.; Palanisamy, P.K.

    2003-01-01

    This paper presents both theoretical and experimental study of the characteristics of Nd: YAG laser pumped energy transfer distributed feedback dye laser (ETDFDL). Using theoretical model proposed, the behavior of ETDFDL such as the characteristics of donor DFDL, the acceptor DFDL, the dependence of their pulse width and output power on donor-acceptor concentrations and pump power are studied for dye mixture Rhodamine 6G and Cresyl Violet in detail. Experimentally using prism-dye cell configuration, the ETDFDL output is obtained and the output energy of DFDL is measured at the emission peaks of donor and acceptor dyes for different pump powers and donor-acceptor concentrations. In addition, the DFDL linewidth measurement has been carried out at the lasing wavelengths of the donor and acceptor dyes using Fabry-Perot etalon and the tunability of DFDL is measured to be in the wavelength range of 545-680 nm

  9. High-Tc thin films prepared by laser ablation: material distribution and droplet problem

    NARCIS (Netherlands)

    Blank, David H.A.; IJsselsteijn, R.P.J.; IJsselsteijn, R.P.J.; Out, P.G.; Kuiper, H.J.H.; Flokstra, Jakob; Rogalla, Horst

    1992-01-01

    The lateral material distribution of laser-deposited YBa2Cu3O7¿¿ films and the density of droplets coming from the target were studied by varying the laser pulse energy, the laser spot size and the target-to-substrate distance. Silicon wafers at ambient temperature were used as substrates to

  10. Broad band tunable dye laser development

    International Nuclear Information System (INIS)

    Lee, Jong Min; Kim, Jung Bog; Kim, Sung Ho; Go, Do Kyung; Lim, Chang Hwan; Rho, Si Pyo; Song, Kyu Seok; Lee, Byung Cheol; Rhi, Jong Hoon; Han, Jae Min; Cha, Hyung Ki; Cha, Byung Hun; Jeong, Do Yung; Han, Jae Min; Jung, Yeu Chang; Im, Ho; Yoo, Choon Sun; Jung, Byung Ik; Seok, Gum Sook

    1992-12-01

    The technical goal and objectives are the development of a tunable laser which can be tuned from UV to near IR and commercialization for uses in various fields. Two kinds of resonators are developed. User can select one resonator and change into the other without changing other parts. GIM type has a linewidth of 5GHz which is able to be used usually, and SLM type is very narrow linewidth of less than 1GHz. Each system can have one or two amplifiers depending on output power or cost. High stability and safety, cost-down, and modules into about 30 components have been tried. We hope that this laser can help developments in researches of university, industry, and institute. (Author)

  11. Dye laser with distributed feedback and with pumping by copper-vapor laser

    Energy Technology Data Exchange (ETDEWEB)

    Mirza, S Yu; Soldatov, A N; Sukhanov, V B

    1983-10-01

    An experimental study was made for determining the characteristics of dye lasers with distributed feedback, not requiring intricate resonator structures, and the feasibility of their pumping with radiation from a metal-vapor laser. The experiments were performed with five different dyes lasing in the yellow-red (510.6 - 578.2 nm) range of the spectrum: rhodamine 110, 6G, S and ocazine 17,1 in ethyl alcohol solution. The optical equipment included a copper-vapor pumping laser with the gas-discharge tube inside a telescopic resonator of the unstable type. Pumping pulses of 20 ns duration were generated at 510.6 and 578.2 nm wavelengths and a 4 kHz repetition rate. The pumping power was varied by means of an interference filter smoothly adjustable through rotation. The pumping laser beam was focused by a cylindrical lens on the dye cell. At optimum dye concentrations, corresponding to a maximum attainable emission power, dye concentrate was added into the circulation system for determining the dependence of the pumping threshold power on the dye concentration. Also measured were the dependence of the emission efficiency on the pumping power and the tuning range of each dye laser. The efficiency was found to remain constant over the pumping power range from threshold level to eight times higher level. The results reveal different angles of laser beam divergence in the vertical plane and in the horizontal plane, the divergence angle being four times larger in the vertical plane. The conversion efficiency increased, without significant changes in spectral characteristics, with a single annular reflector instead of two reflectors. 9 references, 4 figures, 1 table.

  12. Tunable ultraviolet solid-state dye laser based on MPMMA doped with pyrromethene 597

    International Nuclear Information System (INIS)

    Jiang, Y G; Fan, R W; Xia, Y Q; Chen, D Y

    2011-01-01

    Solid-state dye sample based on modified polymethyl methacrylate (MPMMA) co-doped with pyrromethene 597 (PM597), and coumarin 460 (C460) were prepared. A frequency-doubled pulsed Nd:YAG laser is used to pump solid-state dye sample, and the narrow linewidth dye laser of 94.4 mJ was obtained at 582 nm in an oscillator-amplifier configuration. Using a beta-BaB 2 O 4 (BBO) crystal to frequency double the dye laser into ultraviolet (UV), a tuning range from 279 to 305 nm was demonstrated from a single doped PM597 dye. To the best of our knowledge, the UV tuning range is the best under the same condition so far. The conversion slope efficiency from solid dye laser to UV laser was 8.9% and the highest UV laser output energy reached 6.94 mJ at 291 nm

  13. Identification Of Natural Dyes On Archaeological Textile Objects Using Laser Induced Fluorescent Technique

    International Nuclear Information System (INIS)

    Abdel-Kareem, O.; Eltokhy, A.; Harith, M. A.

    2011-01-01

    This study aims to evaluate the use of Laser Fluorescent as a non-destructive technique for identification of natural dyes on archaeological textile objects. In this study wool textile samples were dyed with 10 natural dyes such as cochineal, cutch, henna, indigo, Lac, madder, safflower, saffron, sumac and turmeric. These dyes common present on archaeological textile objects to be used as standard dyed textile samples. These selected natural dyes will be used as known references that can be used a guide to identify unknown archaeological dyes. The dyed textile samples were investigated with laser radiation in different wavelengths to detect the best wavelengths for identification each dye. This study confirms that Laser Florescent is very useful and a rapid technique can be used as a non-destructive technique for identification of natural dyes on archaeological textile objects. The results obtained with this study can be a guide for all conservators in identification of natural organic dyes on archaeological textile objects.

  14. Identification Of Natural Dyes On Archaeological Textile Objects Using Laser Induced Fluorescent Technique

    Science.gov (United States)

    Abdel-Kareem, O.; Eltokhy, A.; Harith, M. A.

    2011-09-01

    This study aims to evaluate the use of Laser Fluorescent as a non-destructive technique for identification of natural dyes on archaeological textile objects. In this study wool textile samples were dyed with 10 natural dyes such as cochineal, cutch, henna, indigo, Lac, madder, safflower, saffron, sumac and turmeric. These dyes common present on archaeological textile objects to be used as standard dyed textile samples. These selected natural dyes will be used as known references that can be used a guide to identify unknown archaeological dyes. The dyed textile samples were investigated with laser radiation in different wavelengths to detect the best wavelengths for identification each dye. This study confirms that Laser Florescent is very useful and a rapid technique can be used as a non-destructive technique for identification of natural dyes on archaeological textile objects. The results obtained with this study can be a guide for all conservators in identification of natural organic dyes on archaeological textile objects.

  15. Droplet printing through bubble contact in the laser forward transfer of liquids

    International Nuclear Information System (INIS)

    Duocastella, M.; Fernandez-Pradas, J.M.; Morenza, J.L.; Serra, P.

    2011-01-01

    The deposition process of the laser-induced forward transfer of liquids at high laser fluences is analyzed through time-resolved imaging. It has been found that, at these conditions, sessile droplets are deposited due to the contact of a generated cavitation bubble with the receptor substrate, in contrast to the jet contact mechanism observed at low and moderate laser fluences. The bubble contact results in droplets with a larger diameter, a smaller contact angle and a lower uniformity than those of the jet mechanism. Therefore, in order to attain a high degree of resolution this mechanism should be prevented.

  16. Droplet printing through bubble contact in the laser forward transfer of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Duocastella, M. [Universitat de Barcelona, Departament de Fisica Aplicada i Optica, Marti i Franques 1, E-08028 Barcelona (Spain); Fernandez-Pradas, J.M., E-mail: jmfernandez@ub.edu [Universitat de Barcelona, Departament de Fisica Aplicada i Optica, Marti i Franques 1, E-08028 Barcelona (Spain); Morenza, J.L.; Serra, P. [Universitat de Barcelona, Departament de Fisica Aplicada i Optica, Marti i Franques 1, E-08028 Barcelona (Spain)

    2011-01-15

    The deposition process of the laser-induced forward transfer of liquids at high laser fluences is analyzed through time-resolved imaging. It has been found that, at these conditions, sessile droplets are deposited due to the contact of a generated cavitation bubble with the receptor substrate, in contrast to the jet contact mechanism observed at low and moderate laser fluences. The bubble contact results in droplets with a larger diameter, a smaller contact angle and a lower uniformity than those of the jet mechanism. Therefore, in order to attain a high degree of resolution this mechanism should be prevented.

  17. High-Energy Laser Interaction with Gases, Droplets, and Bulk Liquids.

    Science.gov (United States)

    Jarzembski, Maurice Anthony

    Breakdown threshold intensities (I_ {rm TH}) were measured as functions of wavelengths and pressure for air, He, Ar, and Xe using a Nd:YAG pulsed laser. Multiphoton absorption dominates in the UV and cascade collision ionization dominates in the IR; however, both can be affected by other electron gain and loss processes. Presence of droplets lowers breakdown of gases due to field enhancements. Breakdown is initiated either in the droplet material or in the gas. At lambda = 0.532mum for a 50 μm dia. water droplet in He, Ar, and air for p pressure. For droplet -in-Xe, at p pressure. For droplet-in-Xe, at p 140 Torr, breakdown occurs outside the droplet and is dependent on gas pressure. Pressure dependence of breakdown was observed for 120mum dia. water droplets in Ar at p > 400 Torr. The required intensity for breakdown of droplet depends on I_{ rm TH} of bulk liquid and the effective field enhancement created by the droplet. The I _{rm TH} of droplet-in-air provides an upper limit to the propagation of a high energy laser beam in the atmosphere containing particles. By geometrical optics approach, a significant field enhancement located at the critical ring region, encircling the axis of the sphere in the forward direction at angle theta_{c}, was discovered where nonlinear processes can occur. This was confirmed experimentally and by Mie theory. Field enhancements calculated at the critical ring for water droplets of different sizes agree well with measurements. For a droplet of given size and real refractive index, the effective field enhancement and the volume over which it occurs are two important factors governing the occurrence of breakdown in droplets for both off resonance and on resonance conditions. Measurements of wavelength dependence of breakdown showed that in the UV, I_{rm TH} for droplets and bulk liquids were comparable and lower by few orders of magnitude from that of air. Transmittance and reflectance of bulk liquids in the UV change with

  18. Investigation of the lasing of dyes under copper vapor laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Danilova, V I; Kopylova, T N; Maier, G V; Masarnovskii, L V; Soldatov, A N; Sukhanov, V B

    1980-10-01

    The lasing characteristics of dyes pumped by copper vapor laser radiation are investigated in order to determine the optimal energetic parameters of the dye-laser system. Expressions are derived for the yields of stimulated emission from dye molecules, and it is shown that the most effective means of improving the lasing characteristics of rhodamine dye solutions is by the modification of intermolecular interactions, in part by the use of multicomponent solutions. Results are then presented of experimental measurements of the emission intensities of combinations of rhodamine dyes irradiated by the 5106-A line of a copper vapor laser. An increase in the lasing efficiency of the acceptor molecule is found for all the dye pairs investigated, with even greater emission intensities observed for multicomponent dye mixtures when the mixtures were pumped transversely. Under longitudinal pumping, improvements in lasing efficiency were obtained only for mixtures of rhodamine 6 Zh with cresil violet.

  19. Laser inactivation of periodontal bacteria using photosensitizing dyes

    Science.gov (United States)

    Golding, Paul S.; Maddocks, L.; King, Terence A.; Drucker, D. B.

    1996-12-01

    We demonstrate the killing of the oral bacteria Prevotella nigrescens using a photosensitizer and light from a 10 Hz, frequency doubled, Q-switched Nd:YAG pumped dye laser, with modified oscillator to increase output power. This system produced light at wavelengths close to 620 nm, the absorption maximum of the photosensitizing agent, malachite green isothiocyanate, a wavelength that is not significantly absorbed by tissue. A bacterial reduction of 97.5 percent was achieved at an energy density of 0.67 J/cm2 and exposure times of 300 seconds.

  20. Angular distribution of ions and extreme ultraviolet emission in laser-produced tin droplet plasma

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hong; Duan, Lian; Lan, Hui [School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074 (China); Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Wang, Xinbing, E-mail: xbwang@hust.edu.cn; Chen, Ziqi; Zuo, Duluo [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Lu, Peixiang [School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2015-05-21

    Angular-resolved ion time-of-flight spectra as well as extreme ultraviolet radiation in laser-produced tin droplet plasma are investigated experimentally and theoretically. Tin droplets with a diameter of 150 μm are irradiated by a pulsed Nd:YAG laser. The ion time-of-flight spectra measured from the plasma formed by laser irradiation of the tin droplets are interpreted in terms of a theoretical elliptical Druyvesteyn distribution to deduce ion density distributions including kinetic temperatures of the plasma. The opacity of the plasma for extreme ultraviolet radiation is calculated based on the deduced ion densities and temperatures, and the angular distribution of extreme ultraviolet radiation is expressed as a function of the opacity using the Beer–Lambert law. Our results show that the calculated angular distribution of extreme ultraviolet radiation is in satisfactory agreement with the experimental data.

  1. Angular distribution of ions and extreme ultraviolet emission in laser-produced tin droplet plasma

    International Nuclear Information System (INIS)

    Chen, Hong; Duan, Lian; Lan, Hui; Wang, Xinbing; Chen, Ziqi; Zuo, Duluo; Lu, Peixiang

    2015-01-01

    Angular-resolved ion time-of-flight spectra as well as extreme ultraviolet radiation in laser-produced tin droplet plasma are investigated experimentally and theoretically. Tin droplets with a diameter of 150 μm are irradiated by a pulsed Nd:YAG laser. The ion time-of-flight spectra measured from the plasma formed by laser irradiation of the tin droplets are interpreted in terms of a theoretical elliptical Druyvesteyn distribution to deduce ion density distributions including kinetic temperatures of the plasma. The opacity of the plasma for extreme ultraviolet radiation is calculated based on the deduced ion densities and temperatures, and the angular distribution of extreme ultraviolet radiation is expressed as a function of the opacity using the Beer–Lambert law. Our results show that the calculated angular distribution of extreme ultraviolet radiation is in satisfactory agreement with the experimental data

  2. The Effect of Glare on Regan Contrast Letter Acuity Scores Using Dye-Based and Reflective Laser Eye Protection

    National Research Council Canada - National Science Library

    Ghani, Nadeem

    2001-01-01

    Current laser eye protection devices (LEPDs) are dye-based or reflective. While both technologies block the laser wavelengths, reflective LEPDs generally transmit more visible light than do dye-based LEPDs...

  3. Development of the plastic solid-dye cell for tunable solid-state dye lasers and study on its optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Do Kyeong; Lee, Jong Min; Cha, Byung Heon; Jung, E. C.; Kim, Hyun Su; Lim, Gwon

    2001-01-01

    we have fabricated solid-state dyes with PMMA and sol-gel materials. We developed single longitudianl mode solid-state dye laser with the linewidth of less than 500MHz. We have constructed a self-seeded laser and observed the increase of the output power because of self-seeding effect. We investigated the operating characteristics of the dualwave laser oscillator and DFDL with solid-state dyes. And we have constructed the 3-color solid-state dye laser oscillator and amplifier system and observed 3-color operation. We also improved the laser oscliiator with disk-type solid-state dye cell which can be translated and rotated with the help of the two stepping motors. With the help of computer control, we could constantly changed the illuminated area of the dye cell and, therefore, were able to achieve long time operation and to use almost the entire region of the solid-state dye cell.

  4. Optimum design of a multi-stage dye-laser amplifier pumped with Cu-vapor lasers

    International Nuclear Information System (INIS)

    Maeda, Mitsuo; Uchiumi, Michihiro

    1990-01-01

    A numerical simulation code, based on the one-dimensional photon transport equation, was developed and analyzed to evaluate the performances of Rhodamine 6G dye laser amplifiers pumped with Cu-vapor lasers. The upper singlet-state absorption played an important role to determine the efficiency. The simulation code was applied to optimize a multi-stage amplifier system with a pulsed or a CW dye-laser oscillator. The analytical results gave a useful guideline to design a high-power pulsed dye-laser system for atomic uranium enrichment. (author)

  5. Polymer photonic crystal dye lasers as label free evanescent cell sensors

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Lopacinska, Joanna M.; Jakobsen, Mogens Havsteen

    2009-01-01

    . The lasers are fabricated by combined nanoimprint and photolithography (CNP) in Ormocore hybrid polymer doped with the laser dye Pyrromethene 597. The lasers emit in the chip plane at a wavelength around 595 nm when pumped with 5 ns pulses from a compact frequency doubled Nd:YAG laser. We investigate...

  6. Single longitudinal mode operation of a solid-state dye laser oscillator

    CERN Document Server

    Lim, G; Kim, H S; Cha, B H; Lee, J M

    2000-01-01

    We have operated a single longitudinal mode of a solid-state dye laser oscillator in a Littman configuration. The host material of the solid-state gain medium was rhodamine dye-doped poly (methyl methacrylate). The pumping source was the second harmonic of a Nd:YAG laser with a repetition rate of 10 Hz. The measured linewidth of the laser output was about 1.5 GHz.

  7. PicoGreen dye as an active medium for plastic lasers

    Science.gov (United States)

    Pradeep, C.; Vallabhan, C. P. G.; Radhakrishnan, P.; Nampoori, V. P. N.

    2015-08-01

    Deoxyribonucleic acid lipid complex thin films are used as a host material for laser dyes. We tested PicoGreen dye, which is commonly used for the quantification of single and double stranded DNA, for its applicability as lasing medium. PicoGreen dye exhibits enhanced fluorescence on intercalation with DNA. This enormous fluorescence emission is amplified in a planar microcavity to achieve yellow lasing. Here the role of DNA is not only a host medium, but also as a fluorescence dequencher. With the obtained results we have ample reasons to propose PicoGreen dye as a lasing medium, which can lead to the development of DNA based bio-lasers.

  8. Optical study of planar waveguides based on oxidized porous silicon impregnated with laser dyes

    Energy Technology Data Exchange (ETDEWEB)

    Chouket, A. [Unite de recherche de Spectroscopie Raman, Departement de Physique, Faculte des Sciences de Tunis, Elmanar 2092, Tunis (Tunisia); Charrier, J. [Laboratoire d' Optronique CNRS-UMR FOTON 6082, Universite de Rennes 1, ENSSAT-6 rue de Kerampont, BP 80518, 22305 Lannion Cedex (France); Elhouichet, H. [Unite de recherche de Spectroscopie Raman, Departement de Physique, Faculte des Sciences de Tunis, Elmanar 2092, Tunis (Tunisia)], E-mail: habib.elhouichet@fst.rnu.tn; Oueslati, M. [Unite de recherche de Spectroscopie Raman, Departement de Physique, Faculte des Sciences de Tunis, Elmanar 2092, Tunis (Tunisia)

    2009-05-15

    Oxidized porous silicon optical planar waveguides were elaborated and impregnated with rhodamine B and rhodamine 6G. The waveguiding, absorption, and photoluminescence properties of these impregnated waveguides were studied. Successful impregnation of the structure with laser dyes is shown from photoluminescence and reflectivity measurements. Furthermore, the reflectivity spectra prove the homogenous incorporation of both dye molecules inside the pores of the matrices. The refractive indices of waveguide layers were determined before and after dye impregnation to indicate the conservation of guiding conditions. The optical losses in the visible wavelengths are studied as a function of dye concentration. The dye absorption is the main reason for these losses.

  9. The copper-pumped dye laser system at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Hackel, R.P.; Warner, B.E.

    1993-01-01

    The Lawrence Livermore National Laboratory's (LLNL) Atomic Vapor Laser Isotope Separation (AVLIS) Program has developed a high-average-power, pulsed, tunable, visible laser system. Testing of this hardware is in progress at industrial scale. The LLNL copper-dye laser system is prototypical of a basic module of a uranium-AVLIS plant. The laser demonstration facility (LDF) system consists of copper vapor lasers arranged in oscillator-amplifier chains providing optical pump power to dye-laser master-oscillator-power-amplifier chains. This system is capable of thousands of watts (average) tunable between 550 and 650 mm. The copper laser system at LLNL consists of 12 chains operating continuously. The copper lasers operate at nominally 4.4 kHz, with 50 ns pulse widths and produce 20 W at near the diffraction limit from oscillators and >250 W from each amplifier. Chains consist of an oscillator and three amplifiers and produce >750 W average, with availabilities >95% (i.e., >8,300 h/y). The total copper laser system power averages ∼9,000 W and has operated at over 10,000 W for extended intervals. The 12 copper laser beams are multiplexed and delivered to the dye laser system where they pump multiple dye laser chains. Each dye chain consists of a master oscillator and three or four power amplifiers. The master oscillator operates at nominally 100 mW with a 50 MHz single mode bandwidth. Amplifiers are designed to efficiently amplify the dye beam with low ASE content and high optical quality. Sustained dye chain powers are up to 1,400 W with dye conversion efficiency >50%, ASE content <5%, and wavefront quality correctable to <λ/10 RMS, using deformable mirrors. Since the timing of the copper laser chains can be offset, the dye laser system is capable of repetition rates which are multiples of 4.4 kHz, up to 26 kHz, limited by the dye pumping system. Development of plant-scale copper and dye laser hardware is progressing in off-line facilities

  10. Femtosecond study of laser dyes soluble in water: coumarins

    International Nuclear Information System (INIS)

    Cassara, Laurence

    1996-01-01

    Coumarins build up one of the great families of laser dyes, and this research thesis addresses the study of four water-soluble coumarins (ATC, DMATC, DATC, and CHOS) which are analogue to conventional coumarins (C120, C311, C1, and C102). These molecules are made water-soluble by substitution of the methyl group in position 4 by a polyether group. Mechanisms of deactivation are studied by means of time-resolved fluorescence and transient adsorption methods which allow the reaction dynamics of coumarins after light excitation to be studied. Several time scales, from femto- to nano-second, have been reached and allowed various processes to be studied: relaxation, solvation dynamics, solute orientation diffusion, process of deactivation of radiative and non-radiative relaxation in various solvents [fr

  11. A dye laser with a partial-selective resonator

    Energy Technology Data Exchange (ETDEWEB)

    Makogon, M M; Sukhanov, V B

    1977-04-01

    The possibility of controlling the width and spectral position of the generation line of an organic dye laser (Rhodamine 6Zh) whose resonator represents a combination of selective and non-selective channels is demonstrated. The selective channel entails an unsymmetrically mounted prism with whose angular displacement the spectral width can be changed within broad ranges; the non-selective channel maintains the resonator's quality at a sufficiently high level. An expression is given which makes it possible to determine the generation's spectral width when fixing the prism's angular position. The change in the rearrangement band was studied in relation to the qualities of the selective and non-selective channels as determined by the form of the active medium's amplification contour (a narrowing of the spectrum from 0.15 to 0.0019 nm led to a reduction of the rearrangement area from 38.4 to 28.3 nm).

  12. Numerical investigation of vessel heating using a copper vapor laser and a pulsed dye laser in treating vascular skin lesions

    Science.gov (United States)

    Pushkareva, A. E.; Ponomarev, I. V.; Isaev, A. A.; Klyuchareva, S. V.

    2018-02-01

    A computer simulation technique was employed to study the selective heating of a tissue vessel using emission from a pulsed copper vapor laser and a pulsed dye laser. The depth and size of vessels that could be selectively and safely removed were determined for the lasers under examination.

  13. CW-laser induced microchannels in dye-polymethacrylic acid films

    OpenAIRE

    M.A. Camacho-López

    2007-01-01

    In this work we report on the formation of microchannels on dye-polymethacrylic acid films using a cw-laser. A focalized beam of a He-Ne laser (632.8 nm emission line) was used to form microchannels on the films. It was found that there exists a laser power density threshold for a pit formation that depends on the dye concentration. The dimensions of the laser-induced channels are dependent on the laser power density. Microchannel formation in the transparent polymethacrylic acid films was no...

  14. Investigation of droplet formation in pulsed Nd:YAG laser deposition of metals and silicon

    Energy Technology Data Exchange (ETDEWEB)

    Siew, Wee-Ong; Lee, Wai-Keat; Wong, Hin-Yong; Tou, Teck-Yong [Multimedia University, Faculty of Engineering, Cyberjaya, Selangor (Malaysia); Yong, Thian-Khok [Multimedia University, Faculty of Engineering, Cyberjaya, Selangor (Malaysia); Universiti Tunku Abdul Rahman, Faculty of Engineering and Science, Kuala Lumpur (Malaysia); Yap, Seong-Shan [Multimedia University, Faculty of Engineering, Cyberjaya, Selangor (Malaysia); Norwegian University of Science and Technology, Institute of Physics, Trondheim (Norway)

    2010-12-15

    In the process of pulsed laser deposition of nickel (Ni) and ruthenium (Ru) thin films, the occurrence of phase explosion in ablation was found to affect the deposition rate and enhance the optical emissions from the plasma plume. Faster thin-film growth rates coincide with the onset of phase explosion as a result of superheating and/or sub-surface boiling which also increased the particulates found on the thin-film surface. These particulates were predominantly droplets which may not be round but flattened and also debris for the case of silicon (Si) ablation. The droplets from Ni and Ru thin films were compared in terms of size distribution and number density for different laser fluences. The origins of these particulates were correlated to the bubble and ripple formations on the targets while the transfer to the thin film surface was attributed to the laser-induced ejection from the targets. (orig.)

  15. Investigation of droplet formation in pulsed Nd:YAG laser deposition of metals and silicon

    International Nuclear Information System (INIS)

    Siew, Wee-Ong; Lee, Wai-Keat; Wong, Hin-Yong; Tou, Teck-Yong; Yong, Thian-Khok; Yap, Seong-Shan

    2010-01-01

    In the process of pulsed laser deposition of nickel (Ni) and ruthenium (Ru) thin films, the occurrence of phase explosion in ablation was found to affect the deposition rate and enhance the optical emissions from the plasma plume. Faster thin-film growth rates coincide with the onset of phase explosion as a result of superheating and/or sub-surface boiling which also increased the particulates found on the thin-film surface. These particulates were predominantly droplets which may not be round but flattened and also debris for the case of silicon (Si) ablation. The droplets from Ni and Ru thin films were compared in terms of size distribution and number density for different laser fluences. The origins of these particulates were correlated to the bubble and ripple formations on the targets while the transfer to the thin film surface was attributed to the laser-induced ejection from the targets. (orig.)

  16. Infantile hemangioma: pulsed dye laser versus surgical therapy

    Science.gov (United States)

    Remlova, E.; Dostalova, T.; Michalusova, I.; Vranova, J.; Jelinkova, H.; Hubacek, M.

    2014-05-01

    Hemangioma is a mesenchymal benign tumor formed by blood vessels. Anomalies affect up to 10% of children and they are more common in females than in males. The aim of our study was to compare the treatment efficacy, namely the curative effect and adverse events, such as loss of pigment and appearance of scarring, between classical surgery techniques and laser techniques. For that reason a group of 223 patients with hemangioma was retrospectively reviewed. For treatment, a pulsed dye laser (PDL) (Rhodamine G, wavelength 595 nm, pulsewidth between 0.45 and 40 ms, spot diameter 7 mm, energy density 9-11 J cm-2) was used and the results were compared with a control group treated with classical surgical therapy under general anesthesia. The curative effects, mainly number of sessions, appearance of scars, loss of pigment, and relapses were evaluated as a marker of successful treatment. From the results it was evident that the therapeutic effects of both systems are similar. The PDL was successful in all cases. The surgery patients had four relapses. Classical surgery is directly connected with the presence of scars, but the system is safe for larger hemangiomas. It was confirmed that the PDL had the optimal curative effect without scars for small lesions (approximately 10 mm). Surgical treatment under general anesthesia is better for large hemangiomas; the disadvantage is the presence of scars.

  17. Comparison of pulsed dye laser versus combined pulsed dye laser and Nd:YAG laser in the treatment of inflammatory acne vulgaris.

    Science.gov (United States)

    Salah El Din, Manal Mohamed; Samy, Nevien Ahmed; Salem, Amira Eid

    2017-06-01

    Both pulsed dye laser and combined 585/1064-nm (sequential dual-wavelength PDL and Nd:YAG) laser improves inflammatory skin disorders including acne vulgaris. To compare the efficacy of 585-nm pulsed dye laser versus sequential dual-wavelength PDL and Nd:YAG in treatment of acne vulgaris. Thirty patients with acne vulgaris were treated by PDL alone on half of the face while contra lateral half was treated by combined 585/1064 nm laser. The study showed that inflammatory acne lesions count was significantly reduced by 82.5% (p 0.0001) on PDL sides and by 83.5% (p 0.00001) on combined 585/1064-nm side after 8 weeks, while reduction of non-inflammatory acne lesions was observed at 8 weeks by 58.4% and 71.5% respectively. However, difference between the two modalities was not statistically significant. PDL and combined PDL/Nd:YAG laser treatment were found to be an effective, safe and well-tolerated treatment option for inflammatory and non-inflammatory acne vulgaris.

  18. Relativistic attosecond electron bunch emission from few-cycle laser irradiated nanoscale droplets

    Directory of Open Access Journals (Sweden)

    Laura Di Lucchio

    2015-02-01

    Full Text Available Attosecond electron bunches produced at the surface of nanometer-scale droplets illuminated by a two-cycle laser pulse are investigated for the purpose of determining their optimal emission characteristics. Significant departures from Mie theory are found for electron bunch emission from droplets whose radii satisfy the condition δ_{r}droplets is subject to a transitional regime which is neither accounted for by optical Mie theory valid for R≫δ, where δ is the usual plasma skin depth, nor with the Rayleigh regime (R<δ≪λ. Instead the angular emission of the bunches is to a good approximation described by the nonlinear ponderomotive scattering model. Subsequently, the bunches are subject to further deflection by the ponderomotive pressure of the copropagating laser field in vacuum, depending on the initial droplet parameters. Final emission angles are estimated, together with the energy spectrum of the bunches.

  19. Micro-Fluidic Dye Ring Laser - Experimental Tuning of the Wavelength and Numerical Simulation of the Cavity Modes

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Balslev, Søren; Mortensen, Niels Asger

    2006-01-01

    We demonstrate wavelength tuning of a micro-fluidic dye ring laser. Wavelength tunability is obtained by controlling the liquid dye concentration. The device performance is modelled by FEM simulations supporting a ray-tracing view.......We demonstrate wavelength tuning of a micro-fluidic dye ring laser. Wavelength tunability is obtained by controlling the liquid dye concentration. The device performance is modelled by FEM simulations supporting a ray-tracing view....

  20. Laser-induced micro-jetting from armored droplets

    KAUST Repository

    Marston, J. O.; Thoroddsen, Sigurdur T

    2015-01-01

    after a nanosecond laser pulse. Using ultra-high-speed imaging up to 320,610 fps, we investigate the extremely rapid dynamics following the cavitation, which manifests itself in the form of a plethora of micro-jets emanating simultaneously from

  1. Picoseconds pulse generation and pulse width determination processes of a distributed feedback dye laser

    International Nuclear Information System (INIS)

    Abdul Ghani, B.; Hammadi, M.

    2004-08-01

    A mathematical model has been developed to describe the dynamic emission of Nd-glass, distributed feedback dye laser (DFDL), and periodical grating temperature. The suggested model allows the investigation of the time behavior of Nd-glass laser and DFDL pulsed. Moreover, it allows studying the effect of the laser input parameters of Nd-glass laser on the spectral characteristics of the output DFDL pulses such as pulse width, delay time, and time separation

  2. Propagation velocities of laser-produced plasmas from copper wire targets and water droplets

    Science.gov (United States)

    Song, Kyo-Dong; Alexander, Dennis R.

    1994-01-01

    Experiments were performed to determine the plasma propagation velocities resulting from KrF laser irradiation of copper wire target (75 microns diameter) and water droplets (75 microns diameter) at irradiance levels ranging from 25 to 150 GW/sq cm. Plasma propagation velocities were measured using a streak camera system oriented orthogonally to the high-energy laser propagation axis. Plasma velocities were studied as a function of position in the focused beam. Results show that both the shape of the plasma formation and material removal from the copper wire are different and depend on whether the targets are focused or slightly defocused (approximately = 0.5 mm movement in the beam axis). Plasma formation and its position relative to the target is an important factor in determining the practical focal point during high-energy laser interaction with materials. At irradiance of 100 GW/sq cm, the air plasma has two weak-velocity components which propagate toward and away from the incident laser while a strong-velocity component propagates away from the laser beam as a detonation wave. Comparison of the measured breakdown velocities (in the range of 2.22-2.27 x 10(exp 5) m/s) for air and the value calculated by the nonlinear breakdown wave theory at irradiance of 100 GW/sq cm showed a quantitative agreement within approximately 50% while the linear theory and Gaussian pulse theory failed. The detonation wave velocities of plasma generated from water droplets and copper wire targets for different focused cases were measured and analyzed theoretically. The propagation velocities of laser-induced plasma liquid droplets obtained by previous research are compared with current work.

  3. Laser-induced stimulated Raman scattering in the forward direction of a droplet - Comparison of Mie theory with geometrical optics

    Science.gov (United States)

    Srivastava, Vandana; Jarzembski, Maurice A.

    1991-01-01

    This paper uses Mie theory to treat electromagnetic scattering and to evaluate field enhancement in the forward direction of a small droplet irradiated by a high-energy beam and compares the results of calculations with the field-enhancement evaluation obtained via geometrical optics treatment. Results of this comparison suggest that the field enhancement located at the critical ring region encircling the axis in the forward direction of the droplet can support laser-induced Raman scattering. The results are supported by experimental observations of the interaction of a 120-micron-diam water droplet with a high-energy Nd:YAG laser beam.

  4. ''Stenungsund-77'': smoke plume measurements with a pulsed dye laser

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, G; Hartmann, B; Spangstedt, G; Steinvall, O

    1977-12-01

    This report describes some of the results obtained in a field experiment at Stenungsund in May 1977, under the support and coordination of the Swedish Space Corporation. We made lidar measurements with a pulsed tunable dye laser working at wavelengths in the uv and visible part of the spectrum. The study concerned SO/sub 2/-absorption, NO/sub 2/-absorption, and particle scattering in the smoke plume of an oil fuel electric power plant. The SO/sub 2/-burden in the plume, near the smoke stack exit, as estimated from our lidar measurements, is compatible with in situ measurements and calculated values. The NO/sub 2/-concentration proved to be lower than the sensitivity limit of our lidar system. The particle scattering experiments led to qualitative results, and only permitted order of magnitude estimates of particle concentrations. They show, however, that a low power, eye safe uv lidar was capable of tracking plumes undiscernible to the eye, out to a distance of 2 to 3 km.

  5. Deposition of organic dyes for dye-sensitized solar cell by using matrix-assisted pulsed laser evaporation

    Directory of Open Access Journals (Sweden)

    Chih-Ping Yen

    2016-08-01

    Full Text Available The deposition of various distinct organic dyes, including ruthenium complex N3, melanin nanoparticle (MNP, and porphyrin-based donor-π-acceptor dye YD2-o-C8, by using matrix-assisted pulsed laser evaporation (MAPLE for application to dye-sensitized solar cell (DSSC is investigated systematically. It is found that the two covalently-bonded organic molecules, i.e., MNP and YD2-o-C8, can be transferred from the frozen target to the substrate with maintained molecular integrity. In contrast, N3 disintegrates in the process, presumably due to the lower bonding strength of metal complex compared to covalent bond. With the method, DSSC using YD2-o-C8 is fabricated, and an energy conversion efficiency of 1.47% is attained. The issue of the low penetration depth of dyes deposited by MAPLE and the possible resolution to it are studied. This work demonstrates that MAPLE could be an alternative way for deposition of organic dyes for DSSC.

  6. Deposition of organic dyes for dye-sensitized solar cell by using matrix-assisted pulsed laser evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Yen, Chih-Ping [Department of Physics, National Taiwan University, Taipei 106, Taiwan (China); Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 106, Taiwan (China); Yu, Pin-Feng [Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 106, Taiwan (China); Department of Physics, National Chung Cheng University, Chiayi 621, Taiwan (China); Wang, Jyhpyng [Department of Physics, National Taiwan University, Taipei 106, Taiwan (China); Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 106, Taiwan (China); Department of Physics, National Central University, Taoyuan 320, Taiwan (China); Lin, Jiunn-Yuan [Department of Physics, National Chung Cheng University, Chiayi 621, Taiwan (China); Chen, Yen-Mu [SuperbIN Co., Ltd., Taipei 114, Taiwan (China); Chen, Szu-yuan, E-mail: sychen@ltl.iams.sinica.edu.tw [Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 106, Taiwan (China); Department of Physics, National Central University, Taoyuan 320, Taiwan (China)

    2016-08-15

    The deposition of various distinct organic dyes, including ruthenium complex N3, melanin nanoparticle (MNP), and porphyrin-based donor-π-acceptor dye YD2-o-C8, by using matrix-assisted pulsed laser evaporation (MAPLE) for application to dye-sensitized solar cell (DSSC) is investigated systematically. It is found that the two covalently-bonded organic molecules, i.e., MNP and YD2-o-C8, can be transferred from the frozen target to the substrate with maintained molecular integrity. In contrast, N3 disintegrates in the process, presumably due to the lower bonding strength of metal complex compared to covalent bond. With the method, DSSC using YD2-o-C8 is fabricated, and an energy conversion efficiency of 1.47% is attained. The issue of the low penetration depth of dyes deposited by MAPLE and the possible resolution to it are studied. This work demonstrates that MAPLE could be an alternative way for deposition of organic dyes for DSSC.

  7. Fluorescence study of some xanthine dyes under stepped laser excitation

    International Nuclear Information System (INIS)

    Chirkova, L.V.; Ketsle, G.A.; Ermagambetov, K.T.

    1996-01-01

    Paper is devoted to definition of triplet state in molecules of xanthine dyes and study of intramolecular energy circulation. Stepped two-quanta excitation of dyes has been carried out with help of experimental unit. Intensive luminescence activated by excitation of triplet molecules of dyes within triplet-triplet band with wave length of 1060 nm was registered for eosin. Given luminescence spectrally coincides with fast fluorescence. 5 refs., 6 figs

  8. QUANTITATIVE DETECTION OF ENVIRONMENTALLY IMPORTANT DYES USING DIODE LASER/FIBER-OPTIC RAMAN

    Science.gov (United States)

    A compact diode laser/fiber-optic Raman spectrometer is used for quantitative detection of environmentally important dyes. This system is based on diode laser excitation at 782 mm, fiber optic probe technology, an imaging spectrometer, and state-of-the-art scientific CCD camera. ...

  9. Evidence for laser emission from the TICT exciplex of coumarin dyes

    International Nuclear Information System (INIS)

    Masilamani, V.

    1987-06-01

    This paper gives confirming evidence for the possibility of super radiant laser emission from the Twisted Internal Charge Transfer (TICT) conformation in exicted state complexation with the solvent, of coumarin family of laser dyes. (author). 6 refs, 1 fig., 2 tabs

  10. ULTRAVIOLET TRANSITIONS IN EUROPIUM STUDIED WITH A FREQUENCY-DOUBLED CW RING DYE-LASER

    NARCIS (Netherlands)

    Eliel, E.R.; Hogervorst, W.; van Leeuwen, K.A.H.; Post, B.H.

    1981-01-01

    High resolution laser spectroscopy has been applied to the study of three ultraviolet transitions in Europium at λ = 294.8, 295.1 and 295.8 nm. The tunable narrowband UV has been generated by intracavity frequency doubling in a cw ring dye laser using a temperate tuned, Brewster angled ADA crystal.

  11. Development of high-power laser technology. Fabrication of a dye cell of the high power dye laser and development of the measurement technology of the fluid velocities in a dye cell

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jae Heung; Chang, Soo; Lim, Kwon; Kim, Jee Teak; Choi, Wan Hae [Hannam University, Taejon (Korea, Republic of)

    1995-08-01

    The computer simulation code for the simulation of the steady-state flow in a dye cell is developed by using the finite element method. The situation of the fluid flow is measured by the diode laser LDV system and compared with results of the computer simulation. The small size Fiber-Optic LDV with a directional coupler is designed and fabricated for the real time measurement of fluid velocities in a dye cell. (author). 13 refs.

  12. Single mode solid state distributed feedback dye laser fabricated by grey scale electron beam lithography on dye doped SU-8 resist

    DEFF Research Database (Denmark)

    Balslev, Søren; Rasmussen, Torben; Shi, Peixiong

    2005-01-01

    We demonstrate grey scale electron beam lithography on functionalized SU-8 resist for fabrication of single mode solid state dye laser devices. The resist is doped with Rhodamine 6G perchlorate and the lasers are based on a first order Bragg grating distributed feedback resonator. The lasers...

  13. Vertical motion and elastic light-scattering of a laser-levitated water droplet

    International Nuclear Information System (INIS)

    Chan, C. W.; Lee, W. K.

    2001-01-01

    We report the vertical motion and elastic scattered light of a single laser-levitated water microdroplet as it slowly evaporated. The vertical displacement as a function of time exhibited peaks of a variety of widths. Morphology-dependent resonances (MDRs) that induced the displacement peaks were identified. We found that the Stokes equation is adequate to describe the vertical motions driven by broad MDRs. For motions driven by relatively narrow MDRs, significant deviations from results predicted by the Stokes equation were found. The elastic scattered light intensity as a function of the size of the droplet showed sudden increases attributable to deformations of the droplet as its size parameter scanned through narrow MDRs. Copyright 2001 Optical Society of America

  14. Third-order nonlinear optical studies of anthraquinone dyes using a CW He–Ne laser

    International Nuclear Information System (INIS)

    Pramodini, S; Poornesh, P

    2014-01-01

    We present investigations on the third-order optical nonlinearity and optical power limiting of anthraquinone dyes. Z-scan measurements were performed using a continuous wave He–Ne laser at 633 nm wavelength as an excitation source. The nonlinear refraction studies exhibited self-defocusing behavior of the dyes. The nonlinear absorption in the dyes was dominated by a reverse saturable absorption process. Self-diffraction ring patterns were observed due to the change in refractive index and thermal lensing. Increase of the electron donating ability of the substituents resulted in enhanced values of the nonlinear optical parameters, establishing the structure–property relationship. The optical limiting study revealed that the dyes possess a lower limiting threshold and clamping level which is very important for eye and sensor protection. Hence, the dyes investigated here emerge as promising candidates for future opto-electronic and photonic device applications such as optical power limiters. (paper)

  15. Third-order nonlinear optical studies of anthraquinone dyes using a CW He-Ne laser

    Science.gov (United States)

    Pramodini, S.; Poornesh, P.

    2014-05-01

    We present investigations on the third-order optical nonlinearity and optical power limiting of anthraquinone dyes. Z-scan measurements were performed using a continuous wave He-Ne laser at 633 nm wavelength as an excitation source. The nonlinear refraction studies exhibited self-defocusing behavior of the dyes. The nonlinear absorption in the dyes was dominated by a reverse saturable absorption process. Self-diffraction ring patterns were observed due to the change in refractive index and thermal lensing. Increase of the electron donating ability of the substituents resulted in enhanced values of the nonlinear optical parameters, establishing the structure-property relationship. The optical limiting study revealed that the dyes possess a lower limiting threshold and clamping level which is very important for eye and sensor protection. Hence, the dyes investigated here emerge as promising candidates for future opto-electronic and photonic device applications such as optical power limiters.

  16. Intensity and absorbed-power distribution in a cylindrical solar-pumped dye laser

    Science.gov (United States)

    Williams, M. D.

    1984-01-01

    The internal intensity and absorbed-power distribution of a simplified hypothetical dye laser of cylindrical geometry is calculated. Total absorbed power is also calculated and compared with laboratory measurements of lasing-threshold energy deposition in a dye cell to determine the suitability of solar radiation as a pump source or, alternatively, what modifications, if any, are necessary to the hypothetical system for solar pumping.

  17. Histologic comparison of the pulsed dye laser and copper vapor laser effects on pig skin

    Energy Technology Data Exchange (ETDEWEB)

    Tan, O.T.; Stafford, T.J.; Murray, S.; Kurban, A.K. (Boston Univ. Medical Center, MA (USA))

    1990-01-01

    Albino pig skin was exposed to the copper vapor (CVL) and flash-lamp pulsed dye (PDL) lasers at 578 nm with a 3 mm diameter spotsize over a range of fluences until purpura and whitening were first established. The total irradiation time was the parameter that was varied in order for the CVL to reach the desired fluence. The lowest fluence producing each clinical endpoint was designated the threshold fluence: 34 J/cm{sup 2} was required to produce purpura using the CVL compared to 7.5 J/cm{sup 2} with the PDL laser. Histologically, skin exposed to purpura fluences from the CVL revealed the presence of constricted, disrupted papillary dermal blood vessels with trapped RBC's within them which were unlike those exposed to PDL where the irradiated vessels were dilated and packed with masses of intravascular agglutinated RBC's. The whitening threshold fluences for the CVL and PDL lasers were 67 J/cm{sup 2} and 29 J/cm{sup 2}, respectively. Streaming of epidermal cells and dermal collagen denaturation were observed in CVL irradiated skin, compared to occasional dyskeratotic epidermal cells and focal dermal collagen denaturation following PDL exposure. The mechanisms responsible for the clinical and histologic changes produced by the two laser systems are discussed.

  18. Tunable lasers in isotope separation: a colorful view of a dye chemist

    International Nuclear Information System (INIS)

    Hammond, P.R.

    1977-01-01

    Some of the problems to be encountered in the possible large scale use of dye lasers in an isotope separation plant are discussed.The effect of laser dye deterioration on performance is examined algebraically in terms of disappearance of dye molecules and the appearance of a new, single chemical product having absorption in the fluorescence band for a single pass through a transversely pumped amplifier. Loss of output, defined as ''quantum yield of laser deterioration'', Q/sub L/, is related to the true quantum yield of molecular destruction of the dye Q/sub M/, and other known parameters. 6-Diethylamino 3-keto fluoran, an example of an oxygen tricyclic merocyanine, is described. It was first reported in the pre-1900 German literature under the name of Chromogen Red B and it is an ineffective lasing dye on account of low fluorescence quantum yield. The techniques for measurement and the excited state absorption cross-sections are reported for the dyes rhodamine 6G fluoroborate in alcohol, rhodamine B basic solution in trifluoroethanol and kiton red S in trifluoroethanol

  19. Pulsed dye laser application in ablation of vascular ectasias of the larynx: a preliminary animal study

    Science.gov (United States)

    Woo, Peak; Wang, Zhi; Perrault, Donald F., Jr.; McMillan, Kathleen; Pankratov, Michail M.

    1995-05-01

    Vascular ectasias (dilatation) and vascular lesions of the larynx are difficult to treat with exciting modalities. Varix (enlarged vessel) of the vocal folds, vocal fold hemorrhage, vascular polyp, hemangioma, intubation or contact granuloma are common problems which disturb voice. Current applications of CO2 laser and cautery often damage the delicate vocal fold cover. The 585 nm dermatologic pulsed dye laser may be an ideal substitute. Two adult canines were examined under anesthesia via microlaryngoscopy technique. Pulsed dye laser (SPTL-1a, Candela Laser Corp., Wayland, MA) energy was delivered via the micromanipulator with the 3.1-mm spot size in single pulses of 6, 8, and 10 Joules/cm2 and applied to the vessels of the vocal folds, epiglottis, and arytenoid cartilage. Endoscopic examination was carried out immediately after the treatment and at 4 weeks postoperatively. The animals were sacrificed at 3 weeks, larynges excised, and whole organ laryngeal section were prepared for histology. Pulsed dye laser thrombosed vessels of the vocal fold using 6 or 8 Joules/cm2. Vascular break and leakage occurred at 10 Joules/cm2. Follow up examination showed excellent vessel obliteration or thrombosis without scarring or injury to the overlying tissues. Histologic examination shows vascular thrombosis without inflammation and fibrosis in the vocal fold cover. Pulsed dye laser may have promise in treatment of vascular lesions of the larynx and upper airway.

  20. Frequency lock of a dye laser emission on iron atomic line top

    International Nuclear Information System (INIS)

    Durand, P.

    1995-03-01

    The aim of this thesis is to realize a frequency lock of a dye laser emission on iron atomic line top. To reach that goal, the author first presents the calculation of atomic vapour density by means of laser absorption ratio measure and studies the dye laser working. It is then necessary to find a device giving the required precision on the frequency of the absorption line choosen. It is obtained thanks to the atomic line reconstitution by optogalvanic effect which gives the reference. Besides, the author presents the necessity of a laser emission power regulation which is obtained thanks to a device including an acoustic and optic modulator. A reliable and accurate captor is choosen and adjusted testing various hollow cathode lamps. The method to obtain the frequency lock of laser emission on iron atomic line top is described. (TEC). 18 refs., 64 figs

  1. Visible laser induced positive ion emissions from NaCl nanoparticles prepared by droplet rapid drying

    International Nuclear Information System (INIS)

    Sun, Mao-Xu; Guo, Deng-Zhu; Xing, Ying-Jie; Zhang, Geng-Min

    2012-01-01

    Highlights: ► NaCl nanoparticles were firstly prepared by heat induced explosion on silicon wafer. ► We found that laser induced ion emissions from NaCl nanoparticles are more prominent. ► We found that water adsorption can efficiently enhance laser induced ion emissions. ► The ultra-photothermal effect in NaCl nanoparticles was observed and explained. - Abstract: A novel convenient way for the formation of sodium chloride (NaCl) nanoparticles on silicon wafer is proposed by using a droplet rapid drying method. The laser induced positive ion emissions from NaCl nanoparticles with and without water treatment is demonstrated by using a laser desorption/ionization time-of-flight mass spectrometer, with laser intensity well below the plasma formation threshold. It is found that the positive ion emissions from NaCl nanoparticles are obviously higher than that from microsize NaCl particles under soft 532 nm laser irradiations, and water adsorption can efficiently enhance the ion emissions from NaCl nanoparticles. The initial kinetic energies of the emitted ions are estimated as 16–17 eV. The synergy of the ultra-thermal effect in nanomaterials, the defect-mediated multiphoton processes, and the existence of intermediate states in NaCl-water interfaces are suggested as the mechanisms.

  2. The development of the intelligent diagnostic expert system for high power dye-laser MOPA system

    International Nuclear Information System (INIS)

    Liu Lianhua; Yang Wenxi; Zhang Xiaowei; Dan Yongjun

    2014-01-01

    A intelligent diagnostic expert system was required to simulate the expert thinking process of solving problem in experiment and to real-time judge the running state of the experiment system. The intelligent diagnostic expert system for dye-laser MOPA system was build with the modular design of separated knowledge base and inference engine, the RETE algorithm rules match, the asynchronous operation, and multithreading technology. The experiment result indicated that the system could real-time analysis and diagnose the running state of dye-laser MOPA system with advantages of high diagnosis efficiency, good instantaneity and strong expansibility. (authors)

  3. High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Dufva, Martin; Kristensen, Anders

    2015-01-01

    imaging refractometry without moving parts is presented. DFB dye lasers are low-cost and highly sensitive refractive index sensors. The unique multi-wavelength DFB laser structure presented here comprises several areas with different grating periods. Imaging in two dimensions of space is enabled...... by analyzing laser light from all areas in parallel with an imaging spectrometer. With this multi-resonance imaging refractometry method, the spatial position in one direction is identified from the horizontal, i.e., spectral position of the multiple laser lines which is obtained from the spectrometer charged...

  4. Random laser emission at dual wavelengths in a donor-acceptor dye mixture solution

    Directory of Open Access Journals (Sweden)

    Sunita Kedia

    Full Text Available The work was aimed to generate random laser emissions simultaneously at two wavelengths in a weakly scattering system containing mixture of binary dyes, rhodamine-B (Rh-B and oxazine-170 (O-170 dispersed with ZnO nano-particles serving as scattering centres. Random lasing performances for individual Rh-B dye were extensively studied for varying small signal gain/scatterer density and we found lasing threshold to significantly depend upon number density of dispersed nano-particles. In spite of inefficient pumping, we demonstrated possibility of random lasing in O-170 dye solution on account of resonance energy transfer from Rh-B dye which served as donor. At optimum concentrations of fluorophores and scatterer in dye mixture solution, incoherent random lasing was effectively attained simultaneously at two wavelengths centered 90 nm apart. Dual-emission intensities, lasing thresholds and rate of amplifications could be controlled and made equivalent for both donor and acceptor in dye mixture solution by appropriate choice of concentrations of dyes and scatterers. Keywords: Random lasing, Energy transfer, Rhodamine-B, Oxazine-170, Zinc oxide

  5. Multilayer Slab Waveguide Distributed Feedback Dye Laser Sensors

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Smith, Cameron; Leung, M.

    2013-01-01

    of DFB lasers. Here, we present a simple yet precise model for calculating the emission wavelength of multilayer DFB lasers. We ¯nd that experimental and calculated wavelength values are in compelling agreement for hybrid nanoimprinted Ormocomp-TiO2 (doped with Pyrromethene 597) ¯rst order DFB lasers [2...

  6. High-speed off-axis holographic cinematography with a copper-vapor-pumped dye laser.

    Science.gov (United States)

    Lauterborn, W; Judt, A; Schmitz, E

    1993-01-01

    A series of coherent light pulses is generated by pumping a dye laser with the pulsed output of a copper-vapor laser at rates of as much as 20 kHz. Holograms are recorded at this pulse rate on a rotating holographic plate. This technique of high-speed holographic cinematography is demonstrated by viewing the bubble filaments that appear in water under the action of a sound field of high intensity.

  7. Picosecond transient backward stimulated Raman scattering and pumping of femtosecond dye lasers

    Science.gov (United States)

    Arrivo, Steven M.; Spears, Kenneth G.; Sipior, Jeffrey

    1995-02-01

    We report studies of transient, backward stimulated, Raman scattering (TBSRS) in solvents with a 10 Hz, 27 ps, 532 nm pump laser. The TBSRS effect was used to create pulses at 545 nm and 630 nm with durations of 2-3 ps and 5-10 μJ of energy. The duration, energy and fluctuations of the Raman pulse were studied as a function of pump energy and focal parameters. A 5 μJ Raman pulse was amplified in either a Raman amplifier or two stage dye amplifier to 1 mJ levels. A 545 nm pulse of 3 ps duration was generated in CCl 4 and was then used to pump a short cavity dye laser (SCDL). The SCDL oscillator and a 5 stage dye amplifier provided a pulse of 700 fs and 400 μJ that was tunable near 590 nm.

  8. Independent tunability of the double-mode-locked cw dye laser.

    LENUS (Irish Health Repository)

    Bourkoff, E

    1979-06-01

    We report a new configuration that enables the double-mode-locked cw dye laser to be independently tunable. In addition, the output coupling at each of the two wavelengths can be independently specified. A series of oscillographs shows some interesting features unique to double mode locking and also shows the effects of varying the two cavity lengths with respect to each other.

  9. Micro-fabricated solid state dye lasers based on a photo-definable polymer

    DEFF Research Database (Denmark)

    Nilsson, Daniel; Balslev, Søren; Gregersen, Misha Marie

    2005-01-01

    the commercially available laser dye Rhodamine 6G, which is incorporated into the SU-8 polymer matrix. The single-mode slab waveguide is formed by three-step spin-coating deposition: a buffer layer of undoped SU-8, a core layer of SU-8 doped with Rhodamine, and a cladding layer of undoped SU-8. (c) 2005 Optical...

  10. Redarkening of port-wine stains 10 years after pulsed-dye-laser treatment

    NARCIS (Netherlands)

    Huikeshoven, Menno; Koster, Petra H. L.; de Borgie, Corianne A. J. M.; Beek, Johan F.; van Gemert, Martin J. C.; van der Horst, Chantal M. A. M.

    2007-01-01

    BACKGROUND: Although pulsed-dye-laser therapy is currently the gold standard for the treatment of port-wine stains, few objective data are available on its long-term efficacy. Using objective color measurements, we performed a 10-year follow-up of a previously conducted prospective clinical study of

  11. Megawatt dye laser oscillator-amplifier system for high resolution spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Drell, P; Chu, S

    1979-03-01

    Peak powers in excess of 4 MW in the visible and 1.3 MW in the uv with linewidths as narrow as 80 MHz are generated with three YAG pumped amplifier stages following a cw dye oscillator. The laser pulses are nearly Fourier transform limited in frequency space and diffraction limited in coordinate space.

  12. How to prevent dimerization of laser dyes in water? Simulation and organic synthesis

    International Nuclear Information System (INIS)

    Dare-Doyen, S.

    2000-01-01

    Xanthenes are widely used as laser dyes in ethanol medium because their photophysical properties there are excellent. On the other hand, when they are dissolved in water, their fluorescence is almost zero on account of the dimerization phenomenon (aggregation of two molecules) which is specific in water although the interaction between the two molecules (these dyes are mainly cations) be repulsive. The first part of this work deals with the dimerization study of two dyes, the 6G rhodamine and the 6G pyronine. Molecular dynamics simulation results (AMBER software) have been compared with those of the NMR; thus it has been possible to describe the geometry of the 6G rhodamine dimer and to identify two structures present in equal quantities for the 6G pyronine dimer. It has been demonstrated that the role of water is essential in the aggregation mechanism; this role can be understood as resulting of the hydrophobic effect. The second part of this work concerns the synthesis of rhodamines which are soluble but not able to dimerize in water at the running concentrations of the laser dyes. At first, aminophenol precursors having hydrophilic ionic groups on modifiable sites have been synthesized without changing their photophysical properties. The synthesis sequence of the 3-(2-alkylamino-4-hydroxyphenyl)propionic acids has not given the waited products but N-(3'-hydroxyphenyl)amino-alkylsulfonic acids have been obtained. Their condensation with the phthalic anhydride has led to dyes of a charge -2 at a pH of 5 in water and which have photophysical properties similar to those of the rhodamine 575 in ethanol and laser emission properties in the emission spectral range of the rhodamine 6G in ethanol. This synthesis work has then led to the preparation of two laser dyes usable in water. (author) [fr

  13. Anomalous dependence of the lasing parameters of dye solutions on the spectrum of microsecond pump laser pulses

    International Nuclear Information System (INIS)

    Tarkovsky, V V; Kurstak, V Yu; Anufrik, S S

    2003-01-01

    The anomalous dependence of the lasing parameters of ethanol solutions of coumarin, rhodamine, oxazine, and laser dyes of other classes on the spectrum of microsecond pump laser pulses is found. The dependence is determined by the shape of the induced singlet - singlet absorption spectra and absorption spectra of short-lived photoproducts. The elucidation of the influence of these factors makes it possible to choose optimal pump spectra and to enhance the efficiency and stability of microsecond dye lasers. (active media)

  14. THERAPY OF SKIN VASCULAR MALFORMATIONS USING COPPER VAPOR LASER AND PULSED DYE LASER

    Directory of Open Access Journals (Sweden)

    Svetlana V. Klyuchareva

    2018-01-01

    Full Text Available Aim. Comparison of effectiveness of the application of copper vapor laser (CVL and pulsed dye laser (PDL in clinical practice. Development of choice criteria of the more effective method of treatment.Materials and methods. The clinical data using CVL and PDL in the treatment of skin vascular malformations are presented. The treatment gave good results in removing of dysplastic skin vessels in 2 and 6 months. The treatment was not painful, and patients did not need general and local anesthesia. The results were presented concerning computer modeling of selective heating of vessels in tissue with CVL and PDL radiation. These results allowed to determine the depth of location and dimensions of vessels for selective and secure removing and the safe dosage ranges were found.Results. On the base of the calculated data, one could conclude that the mode of heating of dysplastic vessels with micropulse series of CVL is more safe and effective than the mode of powerful short pulses in the case of PDL.

  15. Pulsed dye laser treatment of rosacea using a novel 15 mm diameter treatment beam.

    Science.gov (United States)

    Bernstein, Eric F; Schomacker, Kevin; Paranjape, Amit; Jones, Christopher J

    2018-04-10

    The pulsed-dye laser has been used to treat facial redness and rosacea for decades. Recent advances in dye laser technology enable 50% higher output energies supporting 50% larger treatment areas, and beam-diameters up to 15 mm with clinically-relevant fluences. In this study, we investigate this novel pulsed-dye laser using a 15 mm diameter beam for treatment of rosacea. Twenty subjects with erythemato-telangiectatic rosacea were enrolled in the study. A total of 4 monthly treatments were administered, first treating linear vessels with a 3 × 10 mm elliptical beam, then diffuse redness with a 15-mm diameter circular beam. Blinded assessment of digital, cross-polarized photographs taken 2 months following the last treatment was performed using an 11-point clearance scale. Nineteen subjects completed the study. Blinded reviewers correctly identified baseline photos in 55 out of the total of 57 images (96.5%). The blinded reviewers scored 17 of the 19 subjects with an improvement greater than 40%, and 11 of the 19 subjects greater than 50%. The average improvement was 53.9%. Side effects were limited to mild edema, mild to moderate erythema, and mild to moderate bruising. This study demonstrates that a newly designed pulsed-dye laser having a novel 15-mm diameter treatment beam improves the appearance of rosacea with a favorable safety profile. Lasers Surg. Med. 9999:1-5, 2018. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

  16. Milking liquid nano-droplets by an IR laser: a new modality for the visualization of electric field lines

    International Nuclear Information System (INIS)

    Vespini, Veronica; Coppola, Sara; Grilli, Simonetta; Paturzo, Melania; Ferraro, Pietro

    2013-01-01

    Liquid handling at micron- and nano-scale is of paramount importance in many fields of application such as biotechnology and biochemistry. In fact, the microfluidics technologies play an important role in lab-on-a-chip devices and, in particular, the dispensing of liquid droplets is a required functionality. Different approaches have been developed for manipulating, dispensing and controlling nano-droplets under a wide variety of configurations. Here we demonstrate that nano-droplets can be drawn from liquid drop or film reservoirs through a sort of milking effect achieved by the absorption of IR laser radiation into a pyroelectric crystal. The generation of the pyroelectric field induced by the IR laser is calculated numerically and a specific experiment has been designed to visualize the electric field stream lines that are responsible for the liquid milking effect. The experiments performed are expected to open a new route for the visualization, measure and characterization procedures in the case of electrohydrodynamic applications. (paper)

  17. Tracheal anastomosis using indocyanine green dye enhanced fibrinogen with a near-infrared diode laser

    Science.gov (United States)

    Auteri, Joseph S.; Jeevanandam, Valluvan; Oz, Mehmet C.; Libutti, Steven K.; Kirby, Thomas J.; Smith, Craig R.; Treat, Michael R.

    1990-06-01

    A major obstacle to lung transplantation and combined heart- lung transplantation is dehiscence of the tracheobronchial anastomosis. We explored the possibility of laser welded anastomoses in canine tracheas in vivo. Laser anastomoses were performed on three-quarter circumferential anterior tracheotomies. A continous wave diode laser (808 +1 nm) at a power density of 9.6 watts/cm was used. Human fibrinogen was mixed with indocyanine green dye (ICG, max absorbance 805 nm) and applied to the anastomosis site prior to laser exposure. Animals were sacrificed at 0, 21 and 28 days post-operatively. At sacrifice weld bursting pressures were measured by raising intratracheal pressure using forced ventilation via an endotracheal tube. Sutured and laser welded anastomoses had similar bursting pressures, and exhibited satisfactory histologic evidence of healing. However, compared to polypropylene sutured controls, the laser welded anastomoses exhibited less peritracheal inflammatory reaction and showed visibly smoother luminal surfaces at 21 and 28 days post- operatively. Tracheal anastomosis using ICG dye enhanced fibrinogen combined with the near-infrared diode laser is a promising extension of the technology of laser tissue fusion and deserves further study.

  18. Molecular reorientation of dye doped nematic liquid crystals in the laser illumination

    International Nuclear Information System (INIS)

    San, S. E.; Koeysal, O.; Ecevit, F. N.

    2002-01-01

    In this study it is investigated how dye doped nematic liquid crystals reorient under the illumination of laser beam whose wavelength is appropriate to absorbance characteristics of the doping dye. Nematic liquid crystal E7 is used with anthraquinone dye 1% wt/wt in the preparation of the sample and this material is filled in homegenously aligned measurement cell having 15 μm thickness. Mechanism of molecular reorientation includes the absorbance effects of the energy of laser by doping dye and this reorientation causes the refractive index of the material to be changed. There are potential application possibilities of such molecular reorientation based effects in nonlinear optics such as real time holography whose basis is grating diffraction that is observed and investigated in the frame of fundamentals of molecule light interaction mechanisms. Experimental analyses allowed finding characteristic values of diffraction signals depending on physical parameters of set up for a dye doped liquid crystal system and this system provided a 20 % diffraction efficiency under the optimum circumstances

  19. Ionization mechanism of cesium plasma produced by irradiation of dye laser

    International Nuclear Information System (INIS)

    Yamada, Jun; Shibata, Kohji; Uchida, Yoshiyuki; Hioki, Yoshiaki; Sahashi, Toshio.

    1992-01-01

    When a cesium vapor was irradiated by a dye laser which was tuned to the cesium atomic transition line, the number of charged particles produced by the laser radiation was observed. Several sharp peaks in the number of charged particles were observed, which corresponded to the atomic transition where the lower level was the 6P excited atom. The ionization mechanism of the laser-produced cesium plasma has been discussed. An initial electron is produced by laser absorptions of the cesium dimer. When the cesium density is high, many 6P excited atoms are excited by electron collisions. The 6P excited atom further absorbs the laser photon and is ionized through the higher-energy state. As the cesium vapor pressure increases, the resonance effect becomes observable. The 6P excited atom plays dominant role in the ionization mechanism of the laser-produced cesium plasma. (author)

  20. Laser incising of wood: Impregnation of columns with water-soluble dye

    International Nuclear Information System (INIS)

    Hattori, N.; Ando, K.; Kitayama, S.; Nakamura, Y.

    1994-01-01

    To know whether or not laser incising is a useful pre-treatment technique in impregnating a chemical fluid into lumber, pin holes were made in columns of hinoki (Chamaecyparis obtusa Endl.), sugi (Cryptomeria japonica D. Don), karamatsu (Larix leptolepis Gordon) and douglas-fir (Pseudo-tsuga menziesii Franco) with 1.7 kW CO2 laser, and a water-soluble dye was impregnated into these columns with a local pressure impregnation device. Retentions, and lengths and widths of penetrations from each hole were measured quantitatively. Referring to the results of the preparatory experiment mentioned above, incising patterns for sugi and douglas-fir were designed, and the same water-soluble dye was impregnated into the laser-incised columns as well as into non-incised ones with the vacuum-pressure method to obtain penetrated layers with the target depths completely. As a result, a retention of 200 kg/m3 of dye could be achieved for a column of douglas-fir even if it is a species difficult to impregnate. The penetrated layer also could be formed completely at the depth of the laser incision. Therefore, it is concluded that laser incising can be used for the pre-treatment before impregnation of wood columns. (author)

  1. Thermal damage control of dye-assisted laser tissue welding: effect of dye concentration

    Science.gov (United States)

    Xie, Hua; Buckley, Lisa A.; Prahl, Scott A.; Shaffer, Brian S.; Gregory, Kenton W.

    2001-05-01

    Successful laser-assisted tissue welding was implemented to provide proper weld strength with minimized tissue thermal injury. We investigated and compared the weld strengths and morphologic changes in porcine small intestinal submucose (SIS) and porcine ureteral tissues with various concentration of indocyanine green (ICG) and with a solid albumin sheet. The study showed that the tissues were welded at lower ICG concentration (0.05 mM) with minimized tissue thermal damage using an 800-nm wavelength diode laser.

  2. Nanoimprinted distributed feedback dye laser sensor for real-time imaging of small molecule diffusion

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Dufva, Martin; Kristensen, Anders

    2014-01-01

    Label-free imaging is a promising tool for the study of biological processes such as cell adhesion and small molecule signaling processes. In order to image in two dimensions of space current solutions require motorized stages which results in low imaging frame rates. Here, a highly sensitive...... distributed feedback (DFB) dye laser sensor for real-time label-free imaging without any moving parts enabling a frame rate of 12 Hz is presented. The presence of molecules on the laser surface results in a wavelength shift which is used as sensor signal. The unique DFB laser structure comprises several areas...

  3. Development of the plastic solid-dye cell for tunable solid-state dye lasers and study on its optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Do Kyeong; Lee, Jong Min; Cha, Byung Heon; Yi, Jong Hoon; Lee, Kang Soo; Kim, Sung Ho; Lim, Gwon

    2000-01-01

    We have fabricated solid-state dyes with Copolex NK-55, which is the base element of plastic lens, and PMMA. We have measured the longevity of solid-state dyes doped in both polymers and found that PMMA has better properties than Coploex NK-55. We have realized the tuning range of 560-620 nm by doping rhodamine 6Gand rhodamin B in the manufactured solid-state dye laser oscillators. In the standing-wave cavity we achieved the slop efficiency of 10.8 percent and in the grazing incidence cavity, 1.2 percent. We have constructed a very compact grazing- incidence cavity which is only 6 cm long and the linewidth of the laser was less than 1.5 GHz with 3-ns pulse duration. And we have fabricated disk-type solid-state dye cell and installed it in the cavity in which the dye cell can be translated and rotated with the help of the two steeping motors. By this we could constantly changed the illuminated area of the dye cell and , therefore, were able to achieve long time operation and to use almost the entire region of the solid-state dye cell. (author)

  4. Development of the plastic solid-dye cell for tunable solid-state dye lasers and study on its optical properties

    International Nuclear Information System (INIS)

    Ko, Do Kyeong; Lee, Jong Min; Cha, Byung Heon; Yi, Jong Hoon; Lee, Kang Soo; Kim, Sung Ho; Lim, Gwon

    2000-01-01

    We have fabricated solid-state dyes with Copolex NK-55, which is the base element of plastic lens, and PMMA. We have measured the longevity of solid-state dyes doped in both polymers and found that PMMA has better properties than Coploex NK-55. We have realized the tuning range of 560-620 nm by doping rhodamine 6G and rhodamin B in the manufactured solid-state dye laser oscillators. In the standing-wave cavity we achieved the slop efficiency of 10.8 percent and in the grazing incidence cavity, 1.2 percent. We have constructed a very compact grazing- incidence cavity which is only 6 cm long and the linewidth of the laser was less than 1.5 GHz with 3-ns pulse duration. And we have fabricated disk-type solid-state dye cell and installed it in the cavity in which the dye cell can be translated and rotated with the help of the two steeping motors. By this we could constantly changed the illuminated area of the dye cell and , therefore, were able to achieve long time operation and to use almost the entire region of the solid-state dye cell. (author)

  5. Conversion of the luminescence of laser dyes in opal matrices to stimulated emission

    International Nuclear Information System (INIS)

    Alimov, O K; Basiev, T T; Orlovskii, Yu V; Osiko, V V; Samoilovich, M I

    2008-01-01

    The luminescence and laser characteristics of a synthetic opal matrix filled with organic dyes are studied upon excitation by nanosecond laser pulses. The appearance of stimulated emission in a partially ordered scattering medium is investigated. It is shown that if the luminescence spectrum of a dye (oxazine-17) is located far outside the photonic bandgap of the opal matrix, stimulated emission along a preferential direction in the (111) plane is observed when pumping exceeds a threshold even without an external optical cavity. The stimulated emission spectrum is considerably narrower than the luminescence spectrum and consists of several narrow lines located within the dye luminescence band. If the luminescence spectrum of a dye (rhodamine 6G) overlaps with the photonic bandgap of the opal matrix, a different picture is observed. The loss of radiation in the matrix leads to the red shift of the luminescence spectrum, while the stimulated emission as in the case of oxazine-17 lies is observed within the luminescence band. (active media, lasers, and amplifiers)

  6. Single-mode pulsed dye laser pumped by using a diode-pumped Nd:YAG laser with a long pulse width

    CERN Document Server

    Yi, J H; Moon, H J; Rho, S P; Han, J M; Rhee, Y J; Lee, J M

    1999-01-01

    The lasing characteristics of a single-mode dye laser pumped by using a diode-pumped solid-state laser (DPSSL) with a high repetition rate is described. A 45-mm-long Nd:YAG rod was pumped by three CW diode arrays and it was acousto-optically Q-switched. A KTP crystal was used for intracavity frequency doubling. The pulse width of the laser ranged from 90 ns to 200 ns, depending on the diode current and the Q-switching frequency. The single-mode dye laser had a grazing incidence configuration. The pulse width of the dye laser was reduced to about 1/8 of the pumping laser pulse width. The effects of the DPSSL Q-switching frequency, the driving current, and the cavity loss on the dye laser pulse width were investigated by using a simple plane-parallel cavity. From the measured pulse width of the dye laser as a function of the reflectivity of the dye laser output coupler, we found that the cavity loss due to the frequency selection elements and the output coupler should be less than 70 % in order to avoid a drast...

  7. Single-mode pulsed dye laser pumped by using a diode-pumped Nd:YAG laser with a long pulse width

    International Nuclear Information System (INIS)

    Yi, Jong Hoon; Kim, Jin Tae; Moon, Hee Jong; Rho, Si Pyo; Han, Jae Min; Rhee, Yong Joo; Lee, Jong Min

    1999-01-01

    The lasing characteristics of a single-mode dye laser pumped by using a diode-pumped solid-state laser (DPSSL) with a high repetition rate is described. A 45-mm-long Nd:YAG rod was pumped by three CW diode arrays and it was acousto-optically Q-switched. A KTP crystal was used for intracavity frequency doubling. The pulse width of the laser ranged from 90 ns to 200 ns, depending on the diode current and the Q-switching frequency. The single-mode dye laser had a grazing incidence configuration. The pulse width of the dye laser was reduced to about 1/8 of the pumping laser pulse width. The effects of the DPSSL Q-switching frequency, the driving current, and the cavity loss on the dye laser pulse width were investigated by using a simple plane-parallel cavity. From the measured pulse width of the dye laser as a function of the reflectivity of the dye laser output coupler, we found that the cavity loss due to the frequency selection elements and the output coupler should be less than 70 % in order to avoid a drastically reduced pulse width

  8. High-Resolution Infrared Spectroscopy of Imidazole Clusters in Helium Droplets Using Quantum Cascade Lasers

    Science.gov (United States)

    Mani, Devendra; Can, Cihad; Pal, Nitish; Schwaab, Gerhard; Havenith, Martina

    2017-06-01

    Imidazole ring is a part of many biologically important molecules and drugs. Imidazole monomer, dimer and its complexes with water have earlier been studied using infrared spectroscopy in helium droplets^{1,2} and molecular beams^{3}. These studies were focussed on the N-H and O-H stretch regions, covering the spectral region of 3200-3800 \\wn. We have extended the studies on imidazole clusters into the ring vibration region. The imidazole clusters were isolated in helium droplets and were probed using a combination of infrared spectroscopy and mass spectrometry. The spectra in the region of 1000-1100 \\wn and 1300-1460 \\wn were recorded using quantum cascade lasers. Some of the observed bands could be assigned to imidazole monomer and higher order imidazole clusters, using pickup curve analysis and ab initio calculations. Work is still in progress. The results will be discussed in detail in the talk. References: 1) M.Y. Choi and R.E. Miller, J. Phys. Chem. A, 110, 9344 (2006). 2) M.Y. Choi and R.E. Miller, Chem. Phys. Lett., 477, 276 (2009). 3) J. Zischang, J. J. Lee and M. Suhm, J. Chem. Phys., 135, 061102 (2011). Note: This work was supported by the Cluster of Excellence RESOLV (Ruhr-Universitat EXC1069) funded by the Deutsche Forschungsgemeinschaft.

  9. Amplified spontaneous emission and laser emission from a high optical-gain medium of dye-doped dendrimer

    International Nuclear Information System (INIS)

    Yokoyama, Shiyoshi; Nakahama, Tatsuo; Mashiko, Shinro

    2005-01-01

    We measured the amplified spontaneous emission and laser emission from high-gain media of laser-dye encapsulated dendrimers. A highly branched poly(amidoamine) (PAMAM-OH) dendrimer formed a guest-host complex with a conventional laser-dye (DCM), resulting in a high optical-gain. Of particular note was the appearance of a laser threshold, above which a super-narrowed laser spectrum was observed, although laser feedback was caused without any mirror cavity devices. The optical feedback was attributed to spatial confinement of the light due to gain guiding under optical excitation. The laser spectrum clearly indicated a resonant laser-mode with a spectrum linewidth of less than 0.1 nm. This order of spectrum narrowing is comparable to that seen in the laser emission from ordinary laser devices

  10. A comparative study of pulsed dye laser versus long pulsed Nd:YAG laser treatment in recalcitrant viral warts.

    Science.gov (United States)

    Shin, Yo Sup; Cho, Eun Byul; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2017-08-01

    Viral warts are common infectious skin disease induced by human papillomavirus (HPV). But the treatment of recalcitrant warts is still challenging. In this study, we compared the effectiveness of pulsed dye laser (PDL) and long pulsed Nd:YAG (LPNY) laser in the treatment of recalcitrant viral warts. We retrospectively analyzed the medical records of patients with recalcitrant warts treated with laser therapy between January 2013 and February 2016. Seventy-two patients with recalcitrant warts were evaluated. Thirty-nine patients were treated with pulsed dye laser and thirty-three patients were treated with LPNY laser. The following parameters were used: PDL (spot size, 7 mm; pulse duration, 1.5 ms; and fluence, 10-14 J/cm 2 ) and LPNY (spot size, 5 mm; pulse duration, 20 ms; and fluence, 240-300 J/cm 2 ). Complete clearance of two patients (5.1%) in PDL group, and three patients (9.1%) in LPNY group were observed without significant side effects. The patients who achieved at least 50% improvement from baseline were 20 (51.3%) in PDL and 22 (66.7%) in LPNY, respectively. This research is meaningful because we compared the effectiveness of the PDL and LPNY in the recalcitrant warts. Both PDL and LPNY laser could be used as a safe and alternative treatment for recalcitrant warts.

  11. Development of pulsed dye lasers for kidney stone fragmentation

    International Nuclear Information System (INIS)

    Hsia, J.

    1990-01-01

    The idea of using lasers to break stones inside the body was first proposed soon after the appearance of the pulsed ruby laser in 1960. Early work of pioneers in the field such as Mulvaney Pensel, and Tanahashi did not lead to a useful clinical protocol. In 1982, Dr. Graham Watson started a systematic search for the right laser. He soon came to the conclusion that CW lasers that relied on thermal effects were not clinically effective. Q-switched lasers such as ruby and Nd:YAG were eliminated because available optical fibers could not handle the high peak powers they emitted. Animal tests were completed and the first human was successfully treated at MGH by Dr. Stephen Dretler in October, 1985. This was soon followed by treatments at the Institute of Urology in London by Dr. Watson and Dr. Wickham. Today, lasertripsy is the treatment of choice for lower ureteral stones. In this paper the work leading to the development of the first clinically effective laser lithotripsy system is reviewed

  12. Bio-effects of repetitively pulsed ultra-fast distributed feedback dye lasers

    International Nuclear Information System (INIS)

    Khan, N.; Ahmad, M.I.; Sheikh, A.

    1999-01-01

    Results of experimental study showing an unexpected rise in pulses of distributed feedback dye laser (DFDL) output due to temperature accumulation in dye cell during passively Q-Switched, a Mode-locked operation is reported. This unintended increase in number of pulse duration, per pulse energy may cause side-effects when used for selective photo thermolysis. To probe this phenomenon most commonly dye was excited with 10 to 20 pulses of second harmonic of a passively Q-Switched and Mode-locked Nd-YaG laser. The outputs of DFDL and Nd:YaG laser were recorded by Imacon 675-streak camera. The peak of DFDL output pulses was found delayed proportionally from the peak of the NYAG pulses by more than one inter-pulse period of excitation laser. A computer program was used to simulate the experimentally measured delay to estimate thermal decay constants and energy retained by the medium to determine the amount of incremental fluctuations in output. The delay between peaks of Nd:YAG (input) and DFDL(output) pulses was found to vary from 10 to 14 nanoseconds for various cavity lengths. It was found that for smaller inter-pulse periods the effect of gradual build-up satisfies the threshold conditions for some of the pulses that otherwise can not. This may lead to unintended increase in energy fluence causing overexposure-induced side-effects. (author)

  13. Profiling an electrospray plume by laser-induced fluorescence and Fraunhofer diffraction combined to mass spectrometry: influence of size and composition of droplets on charge-state distributions of electrosprayed proteins.

    Science.gov (United States)

    Girod, Marion; Dagany, Xavier; Boutou, Véronique; Broyer, Michel; Antoine, Rodolphe; Dugourd, Philippe; Mordehai, Alex; Love, Craig; Werlich, Mark; Fjeldsted, John; Stafford, George

    2012-07-14

    We investigated how physico-chemical properties of charged droplets are affected by the electrospray process, using simultaneous in situ measurements by laser-induced fluorescence (LIF), Fraunhofer diffraction and mass spectrometry. For this purpose, we implemented a laser-induced-fluorescence profiling setup in conjunction with a fast, high-resolution particle sizing scheme on a modified Agilent Jet Stream electrospray source coupled to a single quadrupole mass analyser. The optical setup permits us to profile the solvent fractionation and the size of the droplets as they evaporate in an electrospray plume by measuring both the angular scattering pattern and emission spectra of a solvatochromic fluorescent dye. Mass spectra are recorded simultaneously. These mass spectrometry and optical spectroscopy investigations allow us to study the relation between the observed charge-state distributions of protein anions and physico-chemical properties of evaporating droplets in the spray plume. By mixing water with methanol, a refolding of cytochrome C is observed as the water percentage increases in the plume due to the preponderant evaporation of volatile methanol.

  14. A novel, simple and efficient dye laser with low amplified spontaneous emission background for analytical fluorescence and ionization spectroscopy

    International Nuclear Information System (INIS)

    Matveev, Oleg I.; Omenetto, Nicolo'

    1995-01-01

    A new, simple, compact and efficient, grazing- incidence type of dye laser is suggested which has a low level of Amplified Spontaneous Emission. By using a Coumarin dye (LD 5000) pumped with a 20 mJ XeCl excimer laser, and a diffraction grating with 3000 grooves/mm, an efficiency of 11%, a spectral bandwidth of 0.6 cm -1 and a tuning range from 458 to 517 nm have been obtained

  15. Variations in thermo-optical properties of neutral red dye with laser ablated gold nanoparticles

    Science.gov (United States)

    Prakash, Anitha; Pathrose, Bini P.; Mathew, S.; Nampoori, V. P. N.; Radhakrishnan, P.; Mujeeb, A.

    2018-05-01

    We have investigated the thermal and optical properties of neutral red dye incorporated with different weight percentage of gold nanoparticles prepared by laser ablation method. Optical absorption studies confirmed the production of spherical nanoparticles and also the interactions of the dye molecules with gold nanoparticles. The quenching of fluorescence and the reduction in the lifetime of gold incorporated samples were observed and was due to the non-radiative energy transfer between the dye molecules and gold nanoparticles. Dual beam thermal lens technique has been employed to measure the heat diffusion in neutral red with various weight percentage of gold nano sol dispersed in ethanol. The significant outcome of the experiment is that, the overall heat diffusion is slower in the presence of gold nano sol compared to that of dye alone sample. Brownian motion is suggested to be the main mechanism of heat transfer under the present conditions. The thermal diffusivity variations of samples with respect to different excitation power of laser were also studied.

  16. Fluorescence fluctuation of Rhodamine 6G dye for high repetition rate laser excitation

    International Nuclear Information System (INIS)

    Singh, Nageshwar; Patel, Hemant K.; Dixit, S.K.; Vora, H.S.

    2013-01-01

    In this paper, fluorescence from Rhodamine 6G dye for stationary and flowing liquid medium, excited by copper vapor laser, operating at 6 kHz pulse repetition frequency, was investigated. Large fluctuations in spectral width (about 5 nm) and spectral intensity in the fluorescence from stationary dye solution were observed, while fluctuations in the spectral width diminish in a flowing dye medium. However, this increases spectral intensity and slightly red shifts the fluorescence peak emission wavelength. Theoretical analysis was carried out to explain the observed results by incorporating the temperature induced refractive index, beam deflection and spectral variation in stationary dye solution. Numerical analysis of thermal load and contour of temperature in the optical pumped region inside the dye cell in stationary, 0.2 and 1.5 m/s flow velocity was also investigated to support our analysis. - Highlights: ► High repetition rate excitation generates inhomogeneity in the gain medium. ► Fluorescence of Rhodamine 6G in stationary and flowing medium was carried out. ► Fluorescence fluctuations lessen in flowing medium in contrast to stationary medium. ► Our theoretical and numerical analysis enlightens the experimented outcome trend.

  17. Long-pulsed dye laser versus long-pulsed dye laser-assisted photodynamic therapy for acne vulgaris: A randomized controlled trial

    DEFF Research Database (Denmark)

    Haedersdal, M.; Togsverd, K.; Wiegell, S.R.

    2008-01-01

    Background: Long-pulsed dye laser (LPDL)-assisted photodynamic therapy has been suggested to be superior to laser alone for acne vulgaris but no evidence is available. Objective: To evaluate the efficacy and safety of LPDL alone versus LPDL in photodynamic therapy with methylaminolevulinic acid...... (MAL-LPDL) for acne vulgaris. Methods: Fifteen patients received a series of 3 full-face LPDL treatments and half-face prelaser MAL treatments; the latter being randomly assigned to the left or right side. Results: Inflammatory lesions were reduced more on MAL-LPDL-treated than on LPDL-treated sides...... to draw conclusions about the efficacy of the LPDL, only about the efficacy of MAL-LPDL compared with LPDL alone. Conclusions: MAL-LPDL is slightly superior to LPDL for the treatment of inflammatory acne Udgivelsesdato: 2008/3...

  18. LASERS, ACTIVE MEDIA: The aqueous-polyelectrolyte dye solution as an active laser medium

    Science.gov (United States)

    Akimov, A. I.; Saletskii, A. M.

    2000-11-01

    The spectral, luminescent, and lasing properties of aqueous solutions of a cationic dye rhodamine 6G with additions of anion polyelectrolytes — polyacrylic and polymethacrylic acids — are studied. It is found that the energy and spectral properties of lasing of these solutions depend on the ratio of concentrations of polyelectrolyte and molecules. It is also found that the lasing parameters of aqueous-polyelectrolyte dye solutions can be controlled by changing the structure of the molecular system. The variation in the structure of aqueous-polyelectrolyte dye solutions of rhodamine 6G resulted in an almost five-fold increase in the lasing efficiency compared to that in aqueous dye solutions.

  19. Single-mode solid-state polymer dye laser fabricated with standard I-line UV lithography

    DEFF Research Database (Denmark)

    Balslev, Søren; Mironov, Andrej; Nilsson, Daniel

    2005-01-01

    We present single-mode solid-state polymer dye lasers fabricated with standard UV lithography. The lasers use a high-order Bragg grating and rely on index-tuning of a photosensitive polymer for waveguiding. The gain medium is Rhodamine 6G.......We present single-mode solid-state polymer dye lasers fabricated with standard UV lithography. The lasers use a high-order Bragg grating and rely on index-tuning of a photosensitive polymer for waveguiding. The gain medium is Rhodamine 6G....

  20. Effect of the background radiation of a copper vapor laser with an unstable resonator on dye lasing

    Energy Technology Data Exchange (ETDEWEB)

    Elaev, V F; Mirza, S M; Sukhanov, V B; Troitskii, V O; Soldatov, A N

    1986-05-01

    Results of an experimental study of the emission divergence of a copper vapor laser with an unstable resonator are reported. It is shown that a copper vapor laser beam can be conveniently treated as a pair of components with a divergence higher or lower than a certain optimal value; the percent ratio of the components varies with the pulse repetition frequency. In the case where a copper vapor laser is used to pump a dye laser, the contribution of the component with the higher divergence to dye lasing does not exceed 1 percent. 7 references.

  1. Microvascular blood flow dynamics associated with photodynamic therapy, pulsed dye laser irradiation and combined regimens

    OpenAIRE

    Smith, TK; Choi, B; Ramirez-San-Juan, JC; Nelson, JS; Osann, K; Kelly, KM

    2006-01-01

    Background and Objectives: Previous in vitro studies demonstrated the potential utility of benzoporphyrin derivative monoacid ring A (BPD) photodynamic therapy (PDT) for vascular destruction. Moreover, the effects of PDT were enhanced when this intervention was followed immediately by pulsed dye laser (PDL) irradiation (PDT/ PDL). We further evaluate vascular effects of PDT alone, PDL alone and PDT/PDL in an in vivo rodent dorsal skinfold model. Study Design/Materials and Methods: A dorsal sk...

  2. Enhanced transduction of photonic crystal dye lasers for gas sensing via swelling polymer film

    DEFF Research Database (Denmark)

    Smith, Cameron; Lind, Johan Ulrik; Christiansen, Mads Brøkner

    2011-01-01

    We present the enhanced transduction of a photonic crystal dye laser for gas sensing via deposition of an additional swelling polymer film. Device operation involves swelling of the polymer film during exposure to specific gases, leading to a change in total effective refractive index. Experimental...... in its application to other intracavity-based detection schemes to enable gas sensing. © 2011 Optical Society of America....

  3. Emission wavelength of multilayer distributed feedback dye lasers

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Smith, Cameron L. C.; Brøkner Christiansen, Mads

    2012-01-01

    Precise emission wavelength modeling is essential for understanding and optimization of distributed feedback (DFB) lasers. An analytical approach for determining the emission wavelength based on setting the propagation constant of the Bragg condition and solving for the resulting slab waveguide m...

  4. Transparent media characterization using sub-pico second dye laser

    International Nuclear Information System (INIS)

    Lamy, F.; Fontaine, J.J.

    1982-01-01

    A new passively mode locked laser source developed at the Center for Laser Studies yielded pulses shorter than 0.14 ps, at a rate of 250 MHz or 0.3 ps pulses at a rate of 500 MHz. The laser and its modes of operation are described. With this source and a second order cross correlation technique similar to the autocorrelation used to determine the pulse duration, time domain reflectometry measurements can be made with a resolution of 40 μm. Three dimensional images can be made by time resolving the backscattered radiation of a beam scanned through a medium. The depth resolution of 0.1 μm can be carried over to the other two dimensions by computer reconstruction. The new technique should have important applications in medicine and biology. Because of the short duration of the laser pulses, high peak intensities can be used without damage to the tissues. Therefore, light measurements can be conducted through a larger depth than with continuous radiation. (orig.)

  5. Laser-induced incandescence of suspended particles as a source of excitation of dye luminescence

    CERN Document Server

    Zelensky, S

    2003-01-01

    The interaction of pulsed YAG-Nd sup 3 sup + laser radiation with submicron light-absorbing particles suspended in an aqueous solution of Rhodamine 6G is investigated experimentally. The experiments demonstrate that the laser-induced incandescence of suspended particles excites the luminescence of the dissolved dye molecules. The mechanism of the luminescence excitation consists in the reabsorption of the thermal radiation within the volume of the sample cell. On the ground of this mechanism of excitation, a method of measurement of the luminescence quantum yield is proposed and realized. The method requires the knowledge of the geometrical parameters of the cell and does not require the use of reference samples.

  6. Thermal Dynamics of Xanthene Dye in Polymer Matrix Excited by Double Pulse Laser Radiation

    Science.gov (United States)

    Samusev, Ilia; Borkunov, Rodion; Tsarkov, Maksim; Konstantinova, Elizaveta; Antipov, Yury; Demin, Maksim; Bryukhanov, Valery

    2018-01-01

    Double-pulse laser excitation of the eosin and silver nanoparticles embedded into polymer media is known to be a method of electronic-vibrational energy deactivation kinetic process information obtaining and polymer thermal dynamics investigation. We have studied the vibrational relaxation processes in dye molecules (eosin) and nanoparticles in polyvinyl alcohol after two time-shifted laser pulses with fast and delayed fluorescence kinetics study. In order to simulate thermal and photophysical processes caused by double photon excitation, we solved heat transfer and energy deactivation differential equations numerically. The simulation allowed us to obtain the value of heat conductivity coefficient of polymer matrix.

  7. Temporal and spatial effects of ablation plume on number density distribution of droplets in an aerosol measured by laser-induced breakdown

    International Nuclear Information System (INIS)

    Yashiro, H.; Kakehata, M.

    2013-01-01

    We proposed and experimentally demonstrated a novel method of evaluating the number density of droplets in an aerosol by laser-induced breakdown. The number density of droplets is evaluated from the volume in which the laser intensity exceeds the breakdown threshold intensity for droplets, and the number of droplets in this volume, which is evaluated by the experimentally observed breakdown probability. This measurement method requires a large number of laser shots for not only precise measurement but also highly temporally and spatially resolved density distribution in aerosol. Laser ablation plumes ejected from liquid droplets generated by breakdown disturb the density around the measurement points. Therefore, the recovery time of the density determines the maximum repetition rate of the probe laser irradiating a fixed point. The expansion range of the ablation plume determines the minimum distance at which the measurement points are unaffected by a neighboring breakdown when multiple laser beams are simultaneously irradiated. These laser irradiation procedures enable the measurement of the number density distribution of droplets in an aerosol at a large number of points within a short measurement time.

  8. Temporal and spatial effects of ablation plume on number density distribution of droplets in an aerosol measured by laser-induced breakdown

    Energy Technology Data Exchange (ETDEWEB)

    Yashiro, H.; Kakehata, M. [Electronics and Photonics Research Institute (ESPRIT), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2013-05-07

    We proposed and experimentally demonstrated a novel method of evaluating the number density of droplets in an aerosol by laser-induced breakdown. The number density of droplets is evaluated from the volume in which the laser intensity exceeds the breakdown threshold intensity for droplets, and the number of droplets in this volume, which is evaluated by the experimentally observed breakdown probability. This measurement method requires a large number of laser shots for not only precise measurement but also highly temporally and spatially resolved density distribution in aerosol. Laser ablation plumes ejected from liquid droplets generated by breakdown disturb the density around the measurement points. Therefore, the recovery time of the density determines the maximum repetition rate of the probe laser irradiating a fixed point. The expansion range of the ablation plume determines the minimum distance at which the measurement points are unaffected by a neighboring breakdown when multiple laser beams are simultaneously irradiated. These laser irradiation procedures enable the measurement of the number density distribution of droplets in an aerosol at a large number of points within a short measurement time.

  9. Second harmonic generation of frequency-locked pulsed dye laser for selective photoionization of T1-203 isotope

    International Nuclear Information System (INIS)

    Lim, Gwon; Jeong, Do Young; Ko, Kwang Hoon; Kim, Jae Woo; Kim, Taek Soo; Rho, Sipyo; Kim, Cheol Jung

    2003-01-01

    We have constructed the frequency-locked pulsed dye laser system. It is composed with a GIM-type oscillator and 3 stage longitudinally pumped amplifiers. The pump laser is the second harmonic of pulse Nd:YAG laser at the repetition rate of 6 kHz. Frequency-locking of dye laser oscillator is actively controlled by the feedback loop between a photoionization signal of T1-203 isotope and a wavelength tuning control. The tuning mirror rotates the order of micro degree per a step of step motor. Feedback system for frequency locking is operated with a PC-based control interface, including the data analysis of photoionization signals and the wavelength control using step pumping method for a medical application. Therefor, the dye laser has to be locked at 583.66 nm for SHG or BBO crystal. With the frequency-locking system, the photoionization experiment has been done for more than 10 hours.

  10. Photophysical characterization of pyrromethene 597 laser dye in cross-linked silicon-containing organic copolymers

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, A.; Agua, D. del [Institut II - Experimentelle und Angewandte Physik, Universitaet Regensburg, Universitaetsstrasse 31, 93053 Regensburg (Germany); Penzkofer, A. [Institut II - Experimentelle und Angewandte Physik, Universitaet Regensburg, Universitaetsstrasse 31, 93053 Regensburg (Germany)], E-mail: alfons.penzkofer@physik.uni-regensburg.de; Garcia, O.; Sastre, R. [Instituto de Ciencia y Tecnologia de Polimeros, CSIC, Juan de la Cierva 3, 28006 Madrid (Spain); Costela, A.; Garcia-Moreno, I. [Instituto de Quimica Fisica ' Rocasolano' , CSIC, Serrano 119, 28006 Madrid (Spain)

    2007-12-06

    Samples of the dipyrromethene-BF{sub 2} dye PM597 incorporated in copolymers of 3-trimethoxysilylpropyl 2-methylprop-2-enoate (TMSPMA, number of polymerizable CC double bonds: {kappa} = 1) with 2-(2-methylprop-2-enoyloxy)ethyl 2-methylprop-2-enoate (EGDMA, {kappa} = 2), [2-(hydroxymethyl)-3-prop-2-(prop-2-enoyloxymethyl)propyl] prop-2-enoate (PETA, {kappa} = 3), and [3-prop-2-enoyloxy-2,2-bis(prop-2-2-enoyloxymethyl)propyl]prop-2-enoate (PETRA, {kappa} = 4) are characterized. The fluorescence quantum distributions, fluorescence quantum yields, degrees of fluorescence polarization, and fluorescence lifetimes are measured. The radiative lifetimes are calculated from fluorescence lifetime and quantum yield. Absorption coefficient spectra are determined from transmission measurements. Absolute absorption cross-section spectra and dye concentrations are obtained by calibration to the radiative lifetimes and to saturable absorptions. Excited-state absorption cross-sections at 527 nm are determined by saturable absorption measurements. The photo-degradation is studied under cw laser excitation conditions and quantum yields of photo-degradation are extracted. The excited-state absorption cross-sections were found to be rather small, and the photo-stability turned out to be high (up to 3 million excitation cycles before degradation) making this class of dipyrromethene dye-doped polymers attractive active laser media. Structural and thermo-mechanical properties of the materials have been determined by Fourier transform infrared spectroscopy, differential scanning calorimetry, thermogravimetry, densitometry, and refractometry. They improve with increasing inter-crossing (copolymerization of TMSPMA with PETA and PETRA). The laser properties of the PM597 doped copolymers were evaluated by transverse pumping with 6 ns laser pulses at 532 nm. The best laser materials resulted to be the 7:3 and 9:1 TMSPMA-monomer copolymers.

  11. Combined pulsed dye laser and fiberoptic Nd-YAG laser for the treatment of hypertrophic port wine stain.

    Science.gov (United States)

    Radmanesh, Mohammed; Radmanesh, Ramin

    2017-10-01

    The hypertrophic Port Wine Stain (PWS) is only partially and superficially treated with the Pulsed dye laser (PDL) because of its limited depth of penetration. We used combined PDL and fiberoptic 1444-nm Nd-YAG laser to treat a case with hypertrophic PWS. After tumescent anesthesia, few holes were made by a 16-gauge needle on different sides of the lesion. The fiberoptic tip of 1444-nm Nd-YAG laser was inserted within the holes and was pushed forward while triggering. In a fan pattern and by a back and forth movement, the subcutaneous and deep dermal areas were coagulated. The skin and outer mucosal surfaces were then treated by PDL. The fiberoptic system used was Accusculpt 1444-nm Nd-YAG laser (Lutronic lasers, South Korea), and the PDL used was 585 nm Nlite system (Chromogenex UK). The parameters used for PDL were fluence = 9 Joules/cm 2 and the spot size was 5 mm. The parameters used for fiberoptic 1444-nm Nd-YAG laser were: Pulse rate = 30 Hz, pulse energy = 300 mJ, power = 6 W, and the total energy = 4000 J for the whole face and mucosa. Little sign of regression and moderate purpura were detected immediately after combined fiberoptic Nd-YAG and PDL therapy. The lesion gradually regressed within 4 months with satisfactory color and volume change. Combined fiberoptic Nd-YAG laser and PDL can be used for the treatment of deeper and superficial layers of hypertrophic PWS.

  12. Nd:YAG (2 omega) pumped dye laser using self-filtering unstable resonator

    CERN Document Server

    Rahimian, K; Hariri, H

    2002-01-01

    A self-filtering unstable resonator with a magnification of M=-3 in a Nd:YAG (2 omega) dye laser has been studied. The dye solution is Rhodamine 6 G in alcohol with the concentration of 5*10 sub - 3 Mol/lit. The spatial intensity distribution of the resonator has been compared has been compared with that of a plane-parallel resonator of equal length. The output energy in both configurations are comparable (20 mu J ,and 26 mu J ,respectively). A significant difference between these two resonators is the laser beam divergence, where beam divergences of 0.77 mrad for the self-filtering unstable resonator and 1.6 mrad for the plane-parallel resonator have been measured. The brightness corresponding to these two resonators are 1.5* 10 sub 1 1 and 2.2* 10 sub 1 0W.cm sub - 2.Sr sub - 1, and the pulse widths are 7 and 17 ns, respectively. These figures show clearly that laser resonator based on the self-filtering unstable resonator design an increase the laser brightness a factor of 10, with a beam divergence of a f...

  13. Photophysical and photochemical study of styrene dyes related to their laser efficiency

    International Nuclear Information System (INIS)

    Meyer, Martine

    1989-01-01

    The photophysical and photochemical properties of two styrene dyes: 4-dicyanomethylene-2-methyl-6-p-dimethylamino-styryl-4H-pyran (DCM) and 7-dimethylamino-3-(-p-formyl-styryl)-1,4-benzoxazine-2-one (DFSBO) have been studied. These molecules have electron donor and electron acceptor groups which give to their fluorescent excited state a charge transfer state character. The red shifts of the absorption and fluorescence spectra in polar solvents and the large Stokes shift related to the increase of the dipole moment from the ground state to the singlet excited state have been fully characterised. The absorption spectra of the first excited singlet and triplet states and the quantum yields of the intersystem crossing to the triplet state have been determined. The existence of conformers of the two dyes has been evidenced. The synthesis of DCM leads to the trans isomer which, under light exposure undergoes photo-isomerization to the cis-compound. Their fluorescence lifetimes and the photo-isomerization efficiency are solvent dependent. The DFSBO emission spectra depend greatly on the excitation wavelength. This effect can be explained by the occurrence of two rotational conformers one being stabilised by an intramolecular hydrogen bond. The spectral properties of these two molecules enable us to explain why DCM is a very good laser dye whereas DFSBO has a poor laser efficiency. (author) [fr

  14. Influences of Nozzle Material on Laser Droplet Brazing Joints with Cu89Sn11 Preforms

    Science.gov (United States)

    Stein, Stefan; Heberle, Johannes; Gürtler, Franz Josef; Cvecek, Kristian; Roth, Stephan; Schmidt, Michael

    This paper presents latest results on the influences of nozzle material and geometry on the electromechanical contacting of sensitive piezoceramic actuator modules. Two nozzle types have been investigated,a standard WC/Co nozzle which is used for soldering applications and a novelceramic nozzle. Applications for active piezoceramic components integrated in structural parts are e.g. active damping, energy harvesting, or monitoring of vibrations and material failure. Anup to now unsolved problem is the electrical contacting of such components without damaging the conductor or the metallization of the ceramic substrate. Since piezoelectric components are to be integrated into structures made of casted aluminum, requirements are high mechanical strength and temperature resistance. Within this paper a method forcontacting piezoceramic modules is presented. A spherical braze preform of tin bronze Cu89Sn11 with a diameter of 600 μm is located in a ceramic nozzle and is subsequently melted by a laser pulse. The liquid solder is ejected from the nozzlevia nitrogen overpressure and wets the surface of the metallization pad and the Cu-wire, resulting in a brazing joint after solidification. The process is called laser droplet brazing (LDB). To asses the thermal evolution during one cycle WC/Co and ZTA have been simulated numerically for two different geometries enabling a proposition weather the geometry or the material properties have a significant influence on the thermal load during one cycle. To evaluate the influence of the nozzle on the joint the positioning accuracy, joint height and detachment times have been evaluated. Results obtained with the ZTA nozzle show comparable positioning accuracies to a WC/Co nozzle with a lower standard deviation of solder detachment time.

  15. Improving the Performance of Gold-Nanoparticle-Doped Solid-State Dye Laser Using Thermal Conversion Effect

    Science.gov (United States)

    An, N. T. M.; Lien, N. T. H.; Hoang, N. D.; Hoa, D. Q.

    2018-04-01

    Energy transfer between spherical gold nanoparticles with size of more than 15 nm and molecules of organic dye 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4 H-pyran (DCM) has been studied. Such radiative energy transfer led to high local temperature, giving rise to a bleaching effect that resulted in rapid degradation of the laser medium. Gold nanoparticles were dispersed at concentrations from 5 × 109 particles/mL to 5 × 1010 particles/mL in DCM polymethylmethacrylate polymer using a radical polymerization process with 2,2'-azobis(isobutyronitrile) (AIBN) as initiator. Using the fast thermoelectric cooling method, the laser medium stability was significantly improved. The output stability of a distributed feedback dye laser pumped by second-harmonic generation from a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser was investigated. Moreover, bidirectional energy transfer between gold nanoparticles and dye molecules was observed.

  16. Preliminary results with sutured colonic anastomoses reinforced with dye-enhanced fibrinogen and a diode laser

    Science.gov (United States)

    Libutti, Steven K.; Williams, Matthew R.; Oz, Mehmet C.; Forde, Kenneth A.; Bass, Lawrence S.; Weinstein, Samuel; Auteri, Joseph S.; Treat, Michael R.; Nowygrod, Roman

    1991-07-01

    A common cause of morbidity in patients recovering from bowel surgery is leakage from colonic anastomoses. A technique utilizing a laser activated protein solder to strengthen colonic anastomoses in a canine model was evaluated. Following creation of six single-layer interrupted suture anastomoses in four dogs, a protein solder consisting of indocyanine green dye and fibrinogen was topically appied to the serosal surface and exposed to 808 nm continuous wave diode laser energy. Immediately following anastomosis, the mean leakage pressure of sutures alone was 129 +/- 14 mm hg (n equals 6), while the mean leakage pressure of sutures reinforced with the laser welded solder was 312 +/- 32 mm hg (n equals 6) (p anastomoses without causing appreciable thermal injury to surrounding tissues.

  17. Coumarin-BODIPY hybrids by heteroatom linkage: versatile, tunable and photostable dye lasers for UV irradiation.

    Science.gov (United States)

    Esnal, I; Duran-Sampedro, G; Agarrabeitia, A R; Bañuelos, J; García-Moreno, I; Macías, M A; Peña-Cabrera, E; López-Arbeloa, I; de la Moya, S; Ortiz, M J

    2015-03-28

    Linking amino and hydroxycoumarins to BODIPYs through the amino or hydroxyl group lets the easy construction of unprecedented photostable coumarin-BODIPY hybrids with broadened and enhanced absorption in the UV spectral region, and outstanding wavelength-tunable laser action within the green-to-red spectral region (∼520-680 nm). These laser dyes allow the generation of a valuable tunable UV (∼260-350 nm) laser source by frequency doubling, which is essential to study accurately the photochemistry of biological molecules under solar irradiation. The tunability is achieved by selecting the substitution pattern of the hybrid. Key factors are the linking heteroatom (nitrogen vs. oxygen), the number of coumarin units joined to the BODIPY framework and the involved linking positions.

  18. Complete electromagnetically induced transparency in sodium atoms excited by a multimode dye laser

    International Nuclear Information System (INIS)

    Alzetta, G.; Gozzini, S.; Lucchesini, A.; Cartaleva, S.; Karaulanov, T.; Marinelli, C.; Moi, L.

    2004-01-01

    Complete electromagnetically induced transparency (EIT) in sodium vapor is demonstrated experimentally by means of excitation with a broadband multimode dye laser tuned on the D 1 line. One hundred percent transparency is observed by excitation of the Na vapor with circularly polarized laser light. The linear polarization excitation produces, instead, complete destruction of the EIT resonance. For laser power density in the 0.1 to 1 W/cm 2 range, the linewidth of the EIT resonance remains in the interval of 90-400 kHz. This complete transparency of the medium in a narrow frequency interval is interesting for many applications where the enhancement of the refractive index is important and where the improvement of the signal-to-noise ratio of the dark resonances allows a more sensitive measurement of weak magnetic fields

  19. Treatment of inflammatory facial acne vulgaris with combination 595-nm pulsed-dye laser with dynamic-cooling-device and 1,450-nm diode laser.

    Science.gov (United States)

    Glaich, Adrienne S; Friedman, Paul M; Jih, Ming H; Goldberg, Leonard H

    2006-03-01

    The 585-nm pulsed-dye laser and the 1,450-nm diode laser have been found effective for the treatment of mild-to-moderate inflammatory facial acne. This study was designed to evaluate the efficacy and safety of the combined treatment with the 595-nm pulsed-dye laser and the 1,450-nm diode laser for inflammatory facial acne. Fifteen patients with inflammatory facial acne were treated with a combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser. Patients' subjective response to treatment was evaluated regarding improvement in acne, acne scarring, oiliness, and redness of the skin. All patients had reductions in acne lesion counts. Mean lesion counts decreased 52% (P < 0.01), 63% (P < 0.01), and 84% (P < 0.01) after one, two, and three treatments, respectively. Patients described moderate-to-marked improvement in acne, acne scarring, and post-inflammatory erythema. Adverse effects were limited to mild, transient erythema. The combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser is safe and effective for the treatment of inflammatory facial acne, acne scarring, and post-inflammatory erythema. 2005 Wiley-Liss, Inc.

  20. Use of reflectance spectrophotometry to predict the response of port wine stains to pulsed dye laser.

    Science.gov (United States)

    Halachmi, Shlomit; Azaria, Ron; Inbar, Roy; Ad-El, Dean; Lapidoth, Moshe

    2014-01-01

    Reflectance spectroscopy can be used to quantitate subtle differences in color. We applied a portable reflectance spectrometer to determine its utility in the evaluation of pulsed dye laser treatment of port wine stains (PWS) and in prediction of clinical outcome, in a prospective study. Forty-eight patients with PWS underwent one to nine pulsed dye laser treatments. Patient age and skin color as well as PWS surface area, anatomic location, and color were recorded. Pretreatment spectrophotometric measurements were performed. The subjective clinical results of treatment and the quantitative spectrophotometry results were evaluated by two independent teams, and the findings were correlated. The impact of the clinical characteristics on the response to treatment was assessed as well. Patients with excellent to good clinical results of laser treatments had pretreatment spectrophotometric measurements which differed by more than 10%, whereas patients with fair to poor results had spectrophotometric measurements with a difference of of less than 10%. The correlation between the spectrophotometric results and the clinical outcome was 73% (p Spectrophotometry has a higher correlation with clinical outcome and a better predictive value than other nonmeasurable, nonquantitative, dependent variables.

  1. Tunable organic distributed feedback dye laser device excited through Förster mechanism

    Science.gov (United States)

    Tsutsumi, Naoto; Hinode, Taiki

    2017-03-01

    Tunable organic distributed feedback (DFB) dye laser performances are re-investigated and characterized. The slab-type waveguide DFB device consists of air/active layer/glass substrate. Active layer consisted of tris(8-quinolinolato)aluminum (Alq3), 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM) dye, and polystyrene (PS) matrix. Effective energy transfer from Alq3 to DCM through Förster mechanism enhances the laser emission. Slope efficiency in the range of 4.9 and 10% is observed at pump energy region higher than 0.10-0.15 mJ cm-2 (lower threshold), which is due to the amplified spontaneous emission (ASE) and lasing. Typical slope efficiency for lasing in the range of 2.0 and 3.0% is observed at pump energy region higher than 0.25-0.30 mJ cm-2 (higher threshold). The tuning wavelength for the laser emission is ranged from 620 to 645 nm depending on the ASE region.

  2. Histopathology of the effects of tuneable dye laser on monkey retina

    Energy Technology Data Exchange (ETDEWEB)

    Smiddy, W.E.; Patz, A.; Quigley, H.A.; Dunkelberger, G.R.

    1988-07-01

    The tuneable dye laser was used to simulate treatment of choroidal neovascularization and panretinal photocoagulation (PRP) in monkey retina. The histopathologic effects of wavelengths from 560 to 630 nm in juxtafoveal, papillomacular bundle, and nonfoveal areas were investigated. An unexpected observation using high-intensity burns in juxtafoveal and, to a lesser extent, in papillomacular bundle areas was inner retinal damage with 600-nm light. At moderate energy levels, the effect of 600 nm were more comparable with those with other wavelengths and included much less damage to the inner retinal layers. At mild energy levels, the effects were comparable with other wavelengths. During and after the application of the burns, the energy levels and ophthalmoscopic appearances were comparable for each wavelength for the high-, moderate-, and mild-intensity burns. The histopathologic effects of 630-nm light (tuneable dye red) were comparable with those of the standard krypton red (647 nm) laser. Nonmacular and PRP effects were similar with all wavelengths. These results indicate that power levels may need to be reduced when placing 600-nm (orange) laser burns in the macula.

  3. UV laser interaction with a fluorescent dye solution studied using pulsed digital holography.

    Science.gov (United States)

    Amer, Eynas; Gren, Per; Sjödahl, Mikael

    2013-10-21

    A frequency tripled Q-switched Nd-YAG laser (wavelength 355 nm, pulse duration 12 ns) has been used to pump Coumarin 153 dye solved in ethanol. Simultaneously, a frequency doubled pulse (532 nm) from the same laser is used to probe the solvent perpendicularly resulting in a gain through stimulated laser induced fluorescence (LIF) emission. The resulting gain of the probe beam is recorded using digital holography by blending it with a reference beam on the detector. Two digital holograms without and with the pump beam were recorded. Intensity maps were calculated from the recorded digital holograms and used to calculate the gain of the probe beam due to the stimulated LIF. In addition numerical data of the local temperature rise was calculated from the corresponding phase maps using Radon inversion. It was concluded that about 15% of the pump beam energy is transferred to the dye solution as heat while the rest is consumed in the radiative process. The results show that pulsed digital holography is a promising technique for quantitative study of fluorescent species.

  4. Argon laser phototherapy of human malignancies using rhodamine-123 as a new laser dye: The intracellular role of oxygen

    International Nuclear Information System (INIS)

    Castro, D.J.; Saxton, R.E.; Markley, J.; Foote, C.S.; Fetterman, H.R.; Castro, D.J.; Ward, P.H.

    1990-01-01

    Recent studies demonstrated that the cationic, mitochondrial-specific dye Rhodamine-123 (Rh-123), is an efficient tumor photosensitizer for Argon laser treatment of human cancer cells both in vitro and in tumors grown as xenografts in athymic mice. To demonstrate the photodynamic mechanism of action of this reaction, the intracellular role of oxygen and temperature changes in treated cells have to be defined. In the current study, a large panel of human tumor cell lines of diverse histologic origin were tested for in vitro sensitivity to Rh-123 and the Argon laser (514.5 nm) in oxygen, deuterium oxide (D2O), and nitrogen (N2) environment. Tumor cells in suspension were first sensitized to Rh-123 (1 or 20 micrograms/ml for 1 hour), cooled on ice to 4 degrees C, and then exposed to the Argon laser (delta T = 14 +/- 1 degree C). Cell proliferation measured by [3H]-thymidine uptake 24 hours after sensitization with Rh-123 and laser treatment was significantly decreased in tumor cells kept in oxygen and D2O atmospheres. No decrease in DNA synthesis was seen in Rh-123 and laser treated cells kept in an N2 environment. Control tumor cells treated with Rh-123 or the Argon laser separately did not show any decreased [3H]-thymidine uptake in oxygen, D2O or N2 environment. These results provide evidence of a photodynamic process since Rh-123 sensitization and Argon laser activation occur at nonthermal levels of energy and are oxygen dependent. The high effectiveness of this technique of photodynamic therapy with the Argon laser, and low toxicity of Rh-123 could make its clinical use very attractive for the treatment of superficial malignancies

  5. Polymer-Optical-Fiber Lasers and Amplifiers Doped with Organic Dyes

    Directory of Open Access Journals (Sweden)

    Joseba Zubia

    2011-07-01

    Full Text Available Polymer optical fibers (POFs doped with organic dyes can be used to make efficient lasers and amplifiers due to the high gains achievable in short distances. This paper analyzes the peculiarities of light amplification in POFs through some experimental data and a computational model capable of carrying out both power and spectral analyses. We investigate the emission spectral shifts and widths and on the optimum signal wavelength and pump power as functions of the fiber length, the fiber numerical aperture and the radial distribution of the dopant. Analyses for both step-index and graded-index POFs have been done.

  6. Conductivity of laser printed copper structures limited by nano-crystal grain size and amorphous metal droplet shell

    International Nuclear Information System (INIS)

    Winter, Shoshana; Zenou, Michael; Kotler, Zvi

    2016-01-01

    We present a study of the morphology and electrical properties of copper structures which are printed by laser induced forward transfer from bulk copper. The percentage of voids and the oxidation levels are too low to account for the high resistivities (∼4 to 14 times the resistivity of bulk monocrystalline copper) of these structures. Transmission electron microscope (TEM) images of slices cut from the printed areas using a focused ion beam (FIB) show nano-sized crystal structures with grain sizes that are smaller than the electron free path length. Scattering from such grain boundaries causes a significant increase in the resistivity and can explain the measured resistivities of the structures. The TEM images also show a nano-amorphous layer (∼5 nm) at the droplet boundaries which also contributes to the overall resistivity. Such morphological characteristics are best explained by the ultrafast cooling rate of the molten copper droplets during printing. (paper)

  7. Experimental test of a four-level kinetic model for excited-state intramolecular proton transfer dye lasers

    Energy Technology Data Exchange (ETDEWEB)

    Costela, A; Munnoz, J M; Douhal, A; Figuera, J M; Acuna, A U [Inst. de Quimica Fisica ' ' Rocasolano' ' , C.S.I.C., Madrid (Spain)

    1989-11-01

    The nanosecond pulses of a dye laser oscillator based on the excited-state intramolecular proton-transfer reaction (IPT) of salicylamide and 2'-hydroxylphenyl benzimidazole dyes have been studied as a function of several experimental parameters. To explain the operation of this laser a numerical four-level kinetic model was developed until the lasing properties of these dyes, in the presence of a variable oxygen concentration and pumped with a double pulse technique, could be reproduced. This was possible only by assuming that the efficiency of the laser is controlled by the absorption cross-section of a transient state with a lifetime in the nanosecond-picosecond range, which was tentatively identified as a ground state tautomeric species. (orig.).

  8. Analysis of liquid samples using dried-droplet laser ablation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Do, Trong-Mui; Hsieh, Hui-Fang; Chang, Wei-Ciang [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, 30013 Taiwan (China); Chang, E.-E. [Department of Biochemistry, Taipei Medical University, Taipei City, 11031 Taiwan (China); Wang, Chu-Fang, E-mail: cfwang@mx.nthu.edu.tw [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, 30013 Taiwan (China); Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2011-08-15

    In this study we developed a dried-droplet method for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method provides accurate and precise results when building calibration curves and determining elements of interest in real liquid samples. After placing just 1 {mu}L of a liquid standard solution or a real sample onto the filter surface and then converting the solution into a very small, thin dry spot, the sample could be applied as an analytical subject for LA. To demonstrate the feasibility of this proposed method, we used LA-ICP-MS and conventional ICP-MS to determine the levels of 13 elements (Li, V, Mn, Co, Ni, Cu, Zn, As, Mo, Cd, Sb, Tl, and Pb) in five water samples. The correlation coefficients obtained from the various calibration curves ranged from 0.9920 ({sup 205}Tl) to 0.9998 ({sup 51}V), sufficient to allow the determination of a wide range of elements in the samples. We also investigated the effects of Methylene Blue (MB) and the NaCl concentration on the elemental analyses. MB could be used as an indicator during the ablation process; its presence in the samples only negligibly influenced the intensities of the signals of most of the tested elements. Notably, high NaCl contents led to signal suppression for some of the elements. In comparison with the established sample introduction by nebulization, our developed technique abrogates the need for time-consuming sample preparation and reduces the possibility of sample contamination.

  9. Distributed-feedback dye laser for picosecond ultraviolet and visible spectroscopy

    International Nuclear Information System (INIS)

    Yaney, Perry P.; Kliner, Dahv A. V.; Schrader, Paul E.; Farrow, Roger L.

    2000-01-01

    We describe the design and operation of a tunable, picosecond laser system for use in time-resolved spectroscopic measurements in the visible and ultraviolet (UV) spectral region. The laser is designed for fine tuning and high wavelength stability. A Nd:YAG-pumped distributed-feedback dye laser (DFDL) generates pulses that are ∼100 ps in duration with a nearly transform-limited linewidth (∼5 GHz) at a 20 Hz repetition rate. The DFDL pulses are amplified in two bow-tie amplifiers, providing pulse energies of up to 3.0 mJ; the amplified pulses may be frequency doubled to the UV spectral region, providing up to 1.0 mJ. The DFDL wavelength is computer stabilized to within ±0.8 pm (±0.7 GHz, two standard deviations), allowing the wavelength to be stationed on a narrow atomic or molecular transition or permitting nearly continuous spectral scans. Application of the laser system to studies of OH energy transfer has been demonstrated; both laser-induced-fluorescence and degenerate-four-wave-mixing spectra have been recorded. (c) 2000 American Institute of Physics

  10. Enhancing the Performance of Distributed Feedback Dye Lasers and Plasmonic V-grooves for Lab-on-a-chip Systems

    DEFF Research Database (Denmark)

    Smith, Cameron

    The ability to perform laboratory operations in compact systems is not only advantageous for the development of diagnostics tools and their production, but also provides unique opportunities to explore the natural world on the micro- and nanoscale. To this end, we focus on two optical schemes: 1...... to the advantages they bring to lab-on-a-chip systems.......) polymer-based distributed feedback (DFB) dye lasers, and 2) plasmonic V-grooves. Regarding the first, DFB dye lasers are well suited to serve as compact, minimal analyte volume and highly sensitive refractive index sensors, where changes occurring in an analyte result in readily measurable shifts...

  11. Dye-enhanced protein solders and patches in laser-assisted tissue welding.

    Science.gov (United States)

    Small, W; Heredia, N J; Maitland, D J; Da Silva, L B; Matthews, D L

    1997-01-01

    This study examines the use of dye-enhanced protein bonding agents in 805 nm diode laser-assisted tissue welding. A comparison of an albumin liquid solder and collagen solid-matrix patches used to repair arteriotomies in an in vitro porcine model is presented. Extrinsic bonding media in the form of solders and patches have been used to enhance the practice of laser tissue welding. Preferential absorption of the laser wavelength has been achieved by the incorporation of chromophores. Both the solder and the patch included indocyanine green dye (ICG) to absorb the 805 nm continuous-wave diode laser light used to perform the welds. Solder-mediated welds were divided into two groups (high power/short exposure and low power/long exposure), and the patches were divided into three thickness groups ranging from 0.1 to 1.3 mm. The power used to activate the patches was constant, but the exposure time was increased with patch thickness. Burst pressure results indicated that solder-mediated and patched welds yielded similar average burst strengths in most cases, but the patches provided a higher success rate (i.e., more often exceeded 150 mmHg) and were more consistent (i.e., smaller standard deviation) than the solder. The strongest welds were obtained using 1.0-1.3 mm thick patches, while the high power/short exposure solder group was the weakest. Though the solder and patches yielded similar acute weld strengths, the solid-matrix patches facilitated the welding process and provided consistently strong welds. The material properties of the extrinsic agents influenced their performance.

  12. Triphenylamine based benzimidazole and benzothiazole: Synthesis and applications in fluorescent chemosensors and laser dyes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang [State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China); University of Chinese Academy of Sciences, Beijing 100039 (China); Li, Bin, E-mail: libinteacher@163.com [State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China); Zhang, Liming; Guan, Yunlong [State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China)

    2014-01-15

    Triphenylamine based fluorescent dyes TPA-benzimidazole and TPA-benzothiazole have been designed and synthesized. The TPA-benzimidazole chemosensor was tested for a number of metal ions and found to exhibit binding affinity for Fe{sup 3+} and Hg{sup 2+} in acetonitrile, and the fluorescence quenching was achieved through a PET process. The appearance of an isosbestic point in absorption titrations and Job's plot analysis supported 1:1 stoichiometries for Fe{sup 3+} and Hg{sup 2+} ions. Laser experiments showed that under transversal pumping with a Q-switched Nd:YAG (355 nm) laser in toluene, TPA-benzothiazole exhibits efficient and stable amplified spontaneous emissions (ASE) at 436 nm. -- Highlights: • Triphenylamine based fluorescent dyes TPA-benzimidazole and TPA-benzothiazole have been designed and synthesized. • The TPA-benzimidazole exhibits binding affinity for Fe{sup 3+} and Hg{sup 2+} in acetonitrile and the fluorescence quenching was achieved through a PET process. • Under transversal pumping at 355 nm in toluene, TPA-benzothiazole exhibits efficient and stable amplified spontaneous emissions (ASE) in 436 nm.

  13. Triphenylamine based benzimidazole and benzothiazole: Synthesis and applications in fluorescent chemosensors and laser dyes

    International Nuclear Information System (INIS)

    Yang, Yang; Li, Bin; Zhang, Liming; Guan, Yunlong

    2014-01-01

    Triphenylamine based fluorescent dyes TPA-benzimidazole and TPA-benzothiazole have been designed and synthesized. The TPA-benzimidazole chemosensor was tested for a number of metal ions and found to exhibit binding affinity for Fe 3+ and Hg 2+ in acetonitrile, and the fluorescence quenching was achieved through a PET process. The appearance of an isosbestic point in absorption titrations and Job's plot analysis supported 1:1 stoichiometries for Fe 3+ and Hg 2+ ions. Laser experiments showed that under transversal pumping with a Q-switched Nd:YAG (355 nm) laser in toluene, TPA-benzothiazole exhibits efficient and stable amplified spontaneous emissions (ASE) at 436 nm. -- Highlights: • Triphenylamine based fluorescent dyes TPA-benzimidazole and TPA-benzothiazole have been designed and synthesized. • The TPA-benzimidazole exhibits binding affinity for Fe 3+ and Hg 2+ in acetonitrile and the fluorescence quenching was achieved through a PET process. • Under transversal pumping at 355 nm in toluene, TPA-benzothiazole exhibits efficient and stable amplified spontaneous emissions (ASE) in 436 nm

  14. A study of the lasing of dyes under the influence of emission from a copper vapor laser

    Energy Technology Data Exchange (ETDEWEB)

    Danilova, V I; Kopylova, T N; Maier, G V; Masarnovskii, L V; Soldatov, A N; Sukhanov, V B

    1980-01-01

    Intense pulsed sources of coherent emission with a continuously tunable wavelength and a high pulse repetition frequency are necessary for atmospheric optics. The use of rhodamine lasing during pumping by a copper dye laser is the most promising. The goals of this work include using the opportunities for improving the lasing properties of dyes pumped by a copper dye laser, choosing dye mixtures that are optimum with respect to their lasing relation, and studying the influence of the dye on their lasing characteristics in order to obtain the optimum energy parameters in the device that is built using a copper vapor laser and an optical attachment. On the basis of an analysis of the equations that describe multiatomic molecular lasing, it is possible to come to a conclusion on the intermolecular processes that determine the lasing effectiveness: singlet-singlet and triplettriplet overabsorption of lasing emission, intercombination (S-T) and internal conversion, and photoconversion in excited electron states. A large probability of emission from the lower singlet state (a large value of the constant of the velocity of radiative decay) is also necessary.

  15. Optical spectroscopy of rubidium Rydberg atoms with a 297 nm frequency doubled dye laser

    International Nuclear Information System (INIS)

    Becker, Th.; Germann, Th.; Thoumany, P.; Stania, G.; Urbonas, L.; Haensch, T.

    2008-01-01

    Full text: Rydberg atoms have played an important role in atomic physics and optical spectroscopy since many years. Due to their long lifetime and the big dipole matrix element between neighbouring Rydberg levels they are an essential tool in microwave cavity-qed experiments. Ultracold Rydberg gases are a promising candidate for realizing controlled quantum gates in atomic ensembles. In most experiments Rydberg atoms are detected destructively, where the optically excited atoms are first ionized followed by an electronic detection of the ionization products. A Doppler-free purely optical detection was reported in a room temperature cell and in an atomic beam apparatus using the technique of electromagnetically induced transparency. In all these experiments the Rydberg atoms are excited with two lasers in a two-step ladder configuration. Here we show that Doppler-free purely optical spectroscopy is also possible with a one step excitation scheme involving a UV laser at 297 nm. We excite the 85 Rb isotope from the 5S 1/2 ground state to the 63P 3/2 state with a frequency doubled dye laser in a room temperature gas cell without buffer gas. Rydberg transitions are detected by monitoring the absorption of 780 nm laser light which is superimposed on the UV light and resonant with one hyperfine component of the Rubidium D2 line. With these two lasers we realize a V-scheme and utilize the quantum amplification effect due to the different natural lifetimes of the upper levels of the two transitions: an excitation into the 63P level hinders many absorption-emission cycles of the D2 transition and leads to a reduced absorption on that line. We discuss the shape of the observed spectra in the context of electron shelving and EIT experiments. By applying a frequency modulation to the UV laser, we can obtain dispersive signals which can be used to stabilize the laser to a specific Rydberg transition. By shifting the frequency of the 780 nm laser to crossover resonances in the

  16. Using the ultra-long pulse width pulsed dye laser and elliptical spot to treat resistant nasal telangiectasia.

    Science.gov (United States)

    Madan, Vishal; Ferguson, Janice

    2010-01-01

    Thick linear telangiectasia on the ala nasi and nasolabial crease can be resistant to treatment with the potassium-titanyl-phosphate (KTP) laser and the traditional round spot on a pulsed dye laser (PDL). We evaluated the efficacy of a 3 mm x 10 mm elliptical spot using the ultra-long pulse width on a Candela Vbeam(R) PDL for treatment of PDL- and KTP laser-resistant nasal telangiectasia. Nasal telangiectasia resistant to PDL (12 patients) and KTP laser (12 patients) in 18 patients were treated with a 3 mm x 10 mm elliptical spot on the ultra-long pulse pulsed dye laser (ULPDL) utilising long pulse width [595 nm, 40 ms, double pulse, 30:20 dynamic cooling device (DCD)]. Six patients had previously received treatment with both PDL and KTP laser prior to ULPDL (40 treatments, range1-4, mean 2.2). Complete clearance was seen in ten patients, and eight patients displayed more than 80% improvement after ULPDL treatment. Self-limiting purpura occurred with round spot PDL and erythema with KTP laser and ULPDL. Subtle linear furrows along the treatment sites were seen in three patients treated with the KTP laser. ULPDL treatment delivered using a 3 mm x 10 mm elliptical spot was non-purpuric and highly effective in the treatment of nasal telangiectasia resistant to KTP laser and PDL.

  17. Observation of rotational revivals for iodine molecules in helium droplets using a near-adiabatic laser pulse

    Science.gov (United States)

    Shepperson, Benjamin; Chatterley, Adam S.; Christiansen, Lars; Søndergaard, Anders A.; Stapelfeldt, Henrik

    2018-01-01

    A 160-ps near-Gaussian, linearly polarized laser pulse is used to align iodine (I2) molecules embedded in helium nanodroplets. The rise time of the laser pulse is sufficiently long and smooth that the alignment, characterized by , behaves adiabatically during the pulse turnon. However, after the laser pulse has turned off stays above 0.50 and a recurrence structure occurs ˜650 ps later. Measurements on isolated (I2) molecules with identical laser pulses are used to identify, through analysis of the observed half- and full-rotational revivals, that the nonadiabatic postpulse alignment dynamics results from a mild truncation of the trailing edge of the laser pulse. This truncation establishes a well-defined starting time for coherent rotation, which leads to the revival structures observed both for isolated molecules and molecules in He droplets. In the latter case the time-dependent trace recorded here is compared to that obtained previously for a 450-fs alignment pulse. It is found that the observed revivals are very similar.

  18. Surface-enhanced Raman spectroscopy on laser-engineered ruthenium dye-functionalized nanoporous gold

    Science.gov (United States)

    Schade, Lina; Franzka, Steffen; Biener, Monika; Biener, Jürgen; Hartmann, Nils

    2016-06-01

    Photothermal processing of nanoporous gold with a microfocused continuous-wave laser at λ = 532 nm provides a facile means in order engineer the pore and ligament size of nanoporous gold. In this report we take advantage of this approach in order to investigate the size-dependence of enhancement effects in surface-enhanced Raman spectroscopy (SERS). Surface structures with laterally varying pore sizes from 25 nm to ≥200 nm are characterized using scanning electron microscopy and then functionalized with N719, a commercial ruthenium complex, which is widely used in dye-sensitized solar cells. Raman spectroscopy reveals the characteristic spectral features of N719. Peak intensities strongly depend on the pore size. Highest intensities are observed on the native support, i.e. on nanoporous gold with pore sizes around 25 nm. These results demonstrate the particular perspectives of laser-fabricated nanoporous gold structures in fundamental SERS studies. In particular, it is emphasized that laser-engineered porous gold substrates represent a very well defined platform in order to study size-dependent effects with high reproducibility and precision and resolve conflicting results in previous studies.

  19. Electronic-excitation energy transfer in heterogeneous dye solutions under laser excitation

    International Nuclear Information System (INIS)

    Levshin, L.V.; Mukushev, B.T.; Saletskii, A.M.

    1995-01-01

    An experimental study has been made of electronic-excitation energy transfer (EEET) among dye molecules of different types for different exciting-fight wavelengths and temperatures. Upon selective laser excitation of the donor, the inhomogeneous broadening of molecular levels increases the probability of EEET from the donor to acceptor molecules. The efficiency of this process is directly proportional to the acceptor molecule concentration and is temperature dependent. The EEET is accompanied by the spectral migration of energy among donor molecules, which reduces the fluorescence quantum efficiency of the donor. Increasing the frequency of the exciting light decreases in the donor fluorescence quantum efficiency. An increase in the acceptor molecule concentration results in a decrease of the spectral migration of excitation in the donor molecule system. 5 refs., 5 figs

  20. Laser-induced removal of a dye C.I. Acid Red 87 using n-type WO{sub 3} semiconductor catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Qamar, M. [Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, KFUPM Box 741, Dhahran 31261 (Saudi Arabia); Gondal, M.A., E-mail: magondal@kfupm.edu.sa [Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, KFUPM Box 741, Dhahran 31261 (Saudi Arabia); Laser Research Laboratory, Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Hayat, K. [Chemistry Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Yamani, Z.H. [Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, KFUPM Box 741, Dhahran 31261 (Saudi Arabia); Laser Research Laboratory, Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Hooshani, K. [Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, KFUPM Box 741, Dhahran 31261 (Saudi Arabia); Chemistry Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2009-10-30

    Water contamination by organic substances such as dyes is of great concern worldwide due to their utilization in many industrial processes and environmental concerns. To cater the needs for waste water treatment polluted with organic dyes, laser-induced photocatalytic process was investigated for removal of a dye derivative namely Acid Red 87 using n-type WO{sub 3} semiconductor catalyst. The degradation was investigated in aqueous suspensions of tungsten oxide under different experimental conditions using laser instead of conventional UV lamp as an irradiation source. The degradation process was monitored by measuring the change in dye concentration as a function of laser irradiation time by employing UV spectroscopic analysis. The degradation of dye was studied by varying different parameters such as laser energy, reaction pH, substrate concentration, catalyst concentration, and in the presence of electron acceptors such as hydrogen peroxide (H{sub 2}O{sub 2}), and potassium bromate (KBrO{sub 3}). The degradation rates were found to be strongly dependent on all the above-mentioned parameters. Our experimental results revealed that the dye degradation process was very fast (within few minutes) under laser irradiation as compared to conventional setups using broad spectral lamps (hours or days) and this laser-induced photocatalytic degradation method could be an effective means to eliminate the pollutants present in liquid phase. The experience gained through this study could be beneficial for treatment of waste water contaminated with organic dyes and other organic pollutants.

  1. Superradiant properties of 4,4'-bis(1¤H¤-phenanthro[9,10-¤d¤]imidazol-2-yl)biphenyl and how a laser dye with exceptional stability can be obtained in only one synthetic step

    DEFF Research Database (Denmark)

    Krebs, Frederik C; Lindvold, Lars René; Jørgensen, M.

    2001-01-01

    The extremely facile synthesis of a very stable laser dye with superradiant properties is reported. The laser action of the dye is demonstrated through a transverse pumping scheme with the advantage that no elaborate laser resonator is required due to the very high gain of the laser medium...

  2. Effects of diode laser welding with dye-enhanced glue on tensile strength of sutures commonly used in urology.

    Science.gov (United States)

    Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W

    1996-01-01

    Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.

  3. Characterization of extreme ultraviolet emission from tin-droplets irradiated with Nd:YAG laser plasmas

    International Nuclear Information System (INIS)

    Aota, T; Nakai, Y; Fujioka, S; Shimomura, M; Nishimura, H; Nishihara, N; Miyanaga, N; Izawa, Y; Mima, K; Fujiwara, E

    2008-01-01

    EUV emission from spherical and planer targets were precisely characterized as an experimental database for use in EUV source generation at high repetition rates. In the single-shot base experiments, conversion efficiency as high as those for the plasma geometry has been demonstrated. The integrated experiment was made with 10 Hz plasma generation, obtained conversion efficiency is low mainly due to unstable positioning of the droplets

  4. Study and realisation of a femtosecond dye laser operating at different wavelengths. Ultrashort pulses compression and amplification

    International Nuclear Information System (INIS)

    Georges, Patrick

    1989-01-01

    We present the study and the realization of a passively mode-locked dye laser producing pulses shorter than 100 femto-seconds (10 -13 s). In a ring cavity with an amplifier medium (Rhodamine 60) and a saturable absorber (DODCI), a sequence of four prisms controls the group velocity dispersion and allows the generation of very short pulses. Then we have studied the production of femtosecond pulses at other wavelengths directly from the femtosecond dye laser. For the first rime, 60 fs pulses at 685 nm and pulses shorter than 50 fs between 775 nm and 800 nm have been produced by passive mode locking. These near infrared pulses have been used to study the absorption saturation kinetics in semiconductors multiple quantum wells GaAs/GaAlAs. We have observed a singular behavior of the laser operating at 685 nm and analyzed the produced pulses in terms of optical solitons. To perform time resolved spectroscopy with shortest pulses, we have studied a pulse compressor and a multipass amplifier to increase the pulses energy. Pulses of 20 fs and 10 micro-joules (peak power: 0.5 GW) have been obtained at low repetition rate (10 Hz) and pulses of 16 fs and 0.6 micro-joules pulses have been generated at high repetition rate (11 kHz) using a copper vapor laser. These pulses have been used to study the absorption saturation kinetics of an organic dye (the Malachite Green). (author) [fr

  5. Treatment of port-wine stains with flash lamp pumped pulsed dye laser on Indian skin: A six year study

    Directory of Open Access Journals (Sweden)

    Chandroth Ponnambath Thajudheen

    2014-01-01

    Full Text Available Context: Port-wine stain (PWS is one of the commonly encountered congenital cutaneous vascular lesions, with an equal sex distribution. Pulsed dye lasers (PDL have revolutionized the treatment of both congential and acquired cutaneous vascular lesions. The pulsed dye lasers owing to its superior efficacy and safety profile have become the gold standard for the management of port-wine stains. Aims: To evaluate the efficacy and side effects of pulsed dye laser for the management of Port-wine stain on Indian skin. Materials and Methods: Seventy five patients of Fitzpatrick skin types IV&V with PWS underwent multiple treatments with PDL (V beam-Candela over a period of six years at monthly intervals. Laser parameters were wavelength 595nm, spot sizes 7-10mm, fluence 6-12 j/cm2, pulse duration 0.45-10ms, along with cryogen cooling. Serial photographs were taken before and after every session. Clinical improvement scores of comparable photographs using a quartile grading (o=80% were judged independently by two dermatologists after the series of treatment. Minimum number of treatments was 6 and maximum 17.They were followed up at six monthly intervals to observe re darkening of PWS. Results: No patient showed total clearance.Grade3 improvement was observed in 70 % of children and 50% of adults after 8-10 sessions. Children showed better and faster response than adults. Thirty percent of patients developed post inflammatory hyper pigmentation which resolved over a period of six to eight weeks. Two patients had superficial scarring due to stacking of pulses. None of the patients showed re darkening of PWS till now. Conclusion: Pulsed dye laser is an effective and safe treatment for port-wine stain in Indian skin.

  6. Rationalizing the photophysical properties of BODIPY laser dyes via aromaticity and electron-donor-based structural perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Waddell, Paul G.; Liu, Xiaogang; Zhao, Teng; Cole, Jacqueline M.

    2015-05-01

    The absorption and fluorescence properties of six boron dipyrromethene (BODIPY) laser dyes with simple non-aromatic substituents are rationalized by relating them to observable structural perturbations within the molecules of the dyes. An empirical relationship involving the structure and the optical properties is derived using a combination of single-crystal X-ray diffraction data, quantum chemical calculations and electronic constants: i.e. the tendency of the pyrrole bond lengths towards aromaticity and the UV-vis absorption and fluorescence wavelengths correlating with the electron-donor properties of the substituents. The effect of molecular conformation on the solid-state optical properties of the dyes is also discussed. The findings in this study also demonstrate the usefulness and limitations of using crystal structure data to develop structure-property relationships in this class of optical materials, contributing to the growing effort to design optoelectronic materials with tunable properties via molecular engineering.

  7. Enhanced optical confinement of dye-doped dielectric nanoparticles using a picosecond-pulsed near-infrared laser

    International Nuclear Information System (INIS)

    Kittiravechote, A; Chiang, W-Y; Usman, A; Liau, I; Masuhara, H

    2014-01-01

    We demonstrate a novel strategy to increase the capability of confining numerous dye-doped polymeric nanobeads (diameter 100 nm) with laser trapping. Unlike most classical works of optical trapping that address mainly the stiffness of the optical trap, our work concerns an increase in the number of particles confined near the laser focus. We developed an imaging system of light scattering in which a condenser lamp was employed to illuminate the focal plane of the objective lens, and the scattering of the incoherent light was specifically measured to determine the number of confined nanobeads. In contrast to preceding work that used mainly continuous-wave or femtosecond-pulsed lasers, we employed a picosecond-pulsed laser with the half-wavelength of the laser particularly falling within the absorption band of the dopant. Our results show that the number of doped nanobeads held by the laser is significantly greater than that of the bare nanobeads of the same dimension. In striking contrast, the confinement of the nanobeads of the two types was comparable when a continuous-wave laser of the same wavelength and power was employed. The number of confined dye-doped nanobeads increased nonlinearly with the power of the pulsed laser; this dependence was fitted satisfactorily with a second-order polynomial. Supported by theoretical analysis, we attribute the enhanced confinement of doped nanobeads in part to an increased effective refractive index resulting from two-photon resonance between the optical field of the laser and the dopant of the nanobead. We envisage that our findings would evoke applications that benefit from controlled confinement or aggregation of nanomaterials with the employment of near-infrared pulsed lasers. (letter)

  8. Efficacy of pulsed dye laser in cosmetically distressing facial dermatoses in skin types IV and V

    Directory of Open Access Journals (Sweden)

    Khandpur Sujay

    2008-01-01

    Full Text Available Background: Pulsed dye laser (PDL has revolutionized treatment of vascular dermatoses. It has been successfully employed to treat several non-vascular conditions in fair skinned individuals without producing significant pigmentary and textural complications. Aim: A preliminary study was undertaken to assess its efficacy in cosmetically distressing facial, vascular and non-vascular dermatoses in Indian patients with skin types IV and V. Materials and Methods: Nine patients of ages 7 to 55 years, with facial verruca plana (VP- 4 cases, angiofibromas (AF- 4 cases and multiple pyogenic granulomas (PG- one case were recruited. They had no systemic complaints. Laser parameters used were (spot size/fluence/wavelength/pulse duration:VP- 5mm/5.5-7.5J/585nm/0.45ms; AF-5mm/6-8.5J/585nm/0.45ms;PG- 5mm/7J/585 and 595nm alternately/1.5ms. Response was assessed clinically and photographically. Results and Conclusions: All VP lesions completely resolved after 2-4 sessions (mean 3.25 sessions, AF showed 50% regression in all cases after 2-3 sessions (mean 2.5 sessions and ≥75% subsidence after 3-7 sessions (mean 5.5 sessions and in PG, after 3 sessions, there was complete subsidence of small satellite lesions with moderate shrinkage of larger papules and complete resolution after 5 sessions. Complications included transient hyperpigmentation/hypopigmentation only. There was no recurrence during next 6 months. PDL offers significant cosmetic improvement in facial dermatoses in Indian patients.

  9. Matrix effect on emission/current correlated analysis in laser-induced breakdown spectroscopy of liquid droplets

    International Nuclear Information System (INIS)

    Huang, J.-S.; Ke, C.-B.; Lin, K.-C.

    2004-01-01

    We have investigated influence of matrix salts on the liquid droplets by laser-induced breakdown spectroscopy (LIBS). An electrospray ionization technique coupled with LIBS is employed to generate the microdroplets of the Na sample solution with various matrix salts added. A sequence of single-shot time-resolved LIB emission signals is detected. The LIB signal intensity integrated within a gate linearly correlates with the plasma-induced current response obtained simultaneously on a single-shot basis. The slopes thus obtained increase with the sample concentration, but appear to be irrespective of different matrix salts, added up to a 2000 mg/l concentration. The matrix salts involved have the same K + cation but different anions. Given a laser radiation emitting at 355 nm with the energy fixed at 23±1 mJ, a limit of detection (LOD) of 1.0 mg/l may be achieved for the Na analysis. The current normalization might have probably taken into account the ablated amount of the sample and the plasma temperature. Accordingly, the LIB/current correlated analysis becomes efficient to suppress the signal fluctuation, improve the LOD determination, and concurrently correct the matrix effect

  10. Treatment of Basal Cell Carcinomas with Pulsed Dye Laser: A Case Series

    Directory of Open Access Journals (Sweden)

    Norman Minars

    2012-01-01

    Full Text Available Background. Basal cell carcinoma (BCC is the most prevalent skin cancer. Because of its highly vascular characteristic, it is amendable to treatment with pulse dye laser (PDL. The goal of this study is to determine the safety and efficacy of PDL therapy for mostly facial BCCs. Materials and Methods. Sixteen men and thirteen women (29 total with 39 biopsy-proven BCCs were treated with 1–4 PDL (595 nm therapies at 2–4-week intervals. The treatment parameters included pulse energy of 15 J/cm 2, pulse length of 3 millisecond, with no dynamic cooling, and 7 mm spot size. The age of the patients was 30–90 years (mean 73 years. Response rates were evaluated by the clinical assessments with mean followup of 11 months. Results. Twenty-four patients with thirty-two tumors reached at least three months followup: 24/32 (75% tumors with complete resolution (mean 3 treatment sessions; 5/32 (16% tumors recurred; 3/32 (9% tumors with incomplete responses after four treatments. Minimal side effects and discomfort were experienced by the patients with PDL therapy. Conclusion. PDL is a safe, tolerable, and moderately effective method of treating various BCCs. The ideal niche and standardized settings for PDL treatment of BCCs are yet to be determined.

  11. Determination of ground and excited state dipole moments of dipolar laser dyes by solvatochromic shift method.

    Science.gov (United States)

    Patil, S K; Wari, M N; Panicker, C Yohannan; Inamdar, S R

    2014-04-05

    The absorption and fluorescence spectra of three medium sized dipolar laser dyes: coumarin 478 (C478), coumarin 519 (C519) and coumarin 523 (C523) have been recorded and studied comprehensively in various solvents at room temperature. The absorption and fluorescence spectra of C478, C519 and C523 show a bathochromic and hypsochromic shifts with increasing solvent polarity indicate that the transitions involved are π→π(∗) and n→π(∗). Onsager radii determined from ab initio calculations were used in the determination of dipole moments. The ground and excited state dipole moments were evaluated by using solvatochromic correlations. It is observed that the dipole moment values of excited states (μe) are higher than corresponding ground state values (μg) for the solvents studied. The ground and excited state dipole moments of these probes computed from ab initio calculations and those determined experimentally are compared and the results are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Comparative Study Between Intense Pulsed Light IPLAND Pulsed Dye Laser In The Treatment Of Striae Distensae

    International Nuclear Information System (INIS)

    El-Khalafawy, Gh.M.K.A.

    2013-01-01

    Pulsed dye laser (PDL) and Intense Pulsed Light (IPL) have been used to treat Striae Distensae (SD). Thirty patients with age ranging from 14 - 42 years were included in this study. Twenty patients were treated on one side of their bodies with PDL and on the other side with IPL while seven patients were treated on both sides by IPL and three patients were treated on both sides by PDL for five sessions with four weeks interval between sessions. Skin biopsies were stained with H and E, Masson Trichrome, Orcein, Alcian blue and anti-collagen I Α1. After both PDL and IPL treatments striae width was decreased and the texture was improved in a highly significant manners where P value was 0.001. Collagen expression was increased in a highly significant manner and P values were <0.001 and 0.004 after PDL and IPL treatments respectively. However, PDL induced expression of collagen I in a highly significant manner compared to the treatment with IPL where P values were <0.001 and 0.193 respectively. Striae rubra gave a superior response with either PDL or IPL compared to striae alba which was evaluated clinically by the width, color and texture, although the histological changes could not verify this consequence. Both PDL and IPL can enhance the clinical picture of striae through collagen stimulation therapeutic modalities

  13. Treatment of Hemorrhagic Vocal Polyps by Pulsed Dye Laser-Assisted Laryngomicrosurgery

    Directory of Open Access Journals (Sweden)

    Hyung Kwon Byeon

    2015-01-01

    Full Text Available Objective. Conventional surgical techniques of laryngomicrosurgery (LMS on hemorrhagic vocal polyps are often difficult due to obscuration of the surgical field by inadvertent bleeding from the lesion, and there are often significant amounts of mucosal epithelium loss. Here, we introduce our surgical technique using pulsed dye laser (PDL, which can effectively resect the polyp with vocal fold mucosa preservation. Methods. Patients who were diagnosed with hemorrhagic vocal polyp and who were surgically managed using PDL from March 2013 to October 2014 were retrospectively reviewed. Preoperative and postoperative clinical outcomes and surgical findings were evaluated. Results. A total of 39 patients were treated with PDL-assisted enucleation LMS. The average age was 43.7 years (range 20–73, and there were 20 males and 19 females (17 professional voice users. In all cases, the hemorrhagic polyp was successfully enucleated after application of PDL, thereby preserving the overlying epithelium. Postoperative voice outcomes were favorable with clear preservation of the vocal fold mucosal wave. Conclusion. PDL-assisted enucleation LMS for the treatment of hemorrhagic vocal polyps can be a safe and effective surgical technique. It can be considered a promising treatment option for hemorrhagic vocal polyps.

  14. Shrinking droplets in electrospray ionization and their influence on chemical equilibria.

    Science.gov (United States)

    Wortmann, Arno; Kistler-Momotova, Anna; Zenobi, Renato; Heine, Martin C; Wilhelm, Oliver; Pratsinis, Sotiris E

    2007-03-01

    We investigated how chemical equilibria are affected by the electrospray process, using simultaneous in situ measurements by laser-induced fluorescence (LIF) and phase Doppler anemometry (PDA). The motivation for this study was the increasing number of publications in which electrospray ionization mass spectrometry is used for binding constant determination. The PDA was used to monitor droplet size and velocity, whereas LIF was used to monitor fluorescent analytes within the electrospray droplets. Using acetonitrile as solvent, we found an average initial droplet diameter of 10 microm in the electrospray. The PDA allowed us to follow the evolution of these droplets down to a size of 1 microm. Rhodamine B-sulfonylchloride was used as a fluorescent analyte within the electrospray. By spatially resolved LIF it was possible to probe the dimerization equilibrium of this dye. Measurements at different spray positions showed no influence of the decreasing droplet size on the monomer-dimer equilibrium. However, with the fluorescent dye pair DCM and oxazine 1 it was shown that a concentration increase does occur within electrosprayed droplets, using fluorescence resonance energy transfer as a probe for the average pair distance.

  15. Ultraviolet laser ablation of fluorine-doped tin oxide thin films for dye-sensitized back-contact solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Huan [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, Hubei, 430074 (China); Fu, Dongchuan [ARC Centre of Excellence for Electromaterials Science, Department of Materials Engineering and School of Chemistry, Monash University, Clayton Victoria, 3800 (Australia); Jiang, Ming [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, Hubei, 430074 (China); Duan, Jun, E-mail: duans@hust.edu.cn [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, Hubei, 430074 (China); Zhang, Fei; Zeng, Xiaoyan [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, Hubei, 430074 (China); Bach, Udo [ARC Centre of Excellence for Electromaterials Science, Department of Materials Engineering and School of Chemistry, Monash University, Clayton Victoria, 3800 (Australia)

    2013-03-01

    In this study, laser ablation of a fluorine-doped tin oxide (FTO) thin film on a glass substrate was conducted using a 355 nm Nd:YVO{sub 4} ultraviolet (UV) laser to obtain a 4 × 4 mm microstructure. The microstructure contains a symmetric set of interdigitated FTO finger electrodes of a monolithic back-contact dye-sensitized solar cell (BC-DSC) on a common substrate. The effects of UV laser ablation parameters (such as laser fluence, repetition frequency, and scanning speed) on the size precision and quality of the microstructure were investigated using a 4 × 4 orthogonal design and an assistant experimental design. The incident photon-to-electron conversion efficiency and the current–voltage characteristics of the BC-DSC base of the interdigitated FTO finger electrodes were also determined. The experimental results show that an FTO film microstructure with high precision and good quality can be produced on a glass substrate via laser ablation with high scanning speed, high repetition frequency, and appropriate laser fluence. - Highlights: ► The ablation width and depth generally depend on the laser fluence. ► The scanning speed and the repetition frequency must match each other. ► Slight ablation of the glass substrate can completely remove F-doped tin oxide.

  16. Experience with esthetic reconstruction of complex facial soft tissue trauma: application of the pulsed dye laser.

    Science.gov (United States)

    Ebrahimi, Ali; Kazemi, Hossein Mohammad; Nejadsarvari, Nasrin

    2014-08-01

    Facial soft tissue injury can be one of the most challenging cases presenting to the plastic surgeon. The life quality and self-esteem of the patients with facial injury may be compromised temporarily or permanently. Immediate reconstruction of most defects leads to better restoration of form and function as well as early rehabilitation. The aim of this study was to present our experience in management of facial soft tissue injuries from different causes. We prospectively studied patients treated by plastic surgeons from 2010 to 2012 suffering from different types of blunt or sharp (penetrating) facial soft tissue injuries to the different areas of the face. All soft tissue injuries were treated primarily. Photography from all patients before, during, and after surgical reconstruction was performed and the results were collected. We used early pulsed dye laser (PDL) post-operatively. In our study, 63 patients including 18 (28.5%) women and 45 (71.5%) men aged 8-70 years (mean 47 years) underwent facial reconstruction due to soft tissue trauma in different parts of the face. Sharp wounds were seen in 15 (23%) patients and blunt trauma lacerations were seen in 52 (77%) patients. Overall, 65% of facial injuries were repaired primary and the remainder were reconstructed with local flaps or skin graft from adjacent tissues. Postoperative PDL therapy done two weeks following surgery for all scars yielded good results in our cases. Analysis of the injury including location, size, and depth of penetration as well as presence of associated injuries can aid in the formulation of a proper surgical plan. We recommend PDL in the early post operation period (two weeks) after suture removal for better aesthetic results.

  17. Peculiarities of the statistics of spectrally selected fluorescence radiation in laser-pumped dye-doped random media

    Science.gov (United States)

    Yuvchenko, S. A.; Ushakova, E. V.; Pavlova, M. V.; Alonova, M. V.; Zimnyakov, D. A.

    2018-04-01

    We consider the practical realization of a new optical probe method of the random media which is defined as the reference-free path length interferometry with the intensity moments analysis. A peculiarity in the statistics of the spectrally selected fluorescence radiation in laser-pumped dye-doped random medium is discussed. Previously established correlations between the second- and the third-order moments of the intensity fluctuations in the random interference patterns, the coherence function of the probe radiation, and the path difference probability density for the interfering partial waves in the medium are confirmed. The correlations were verified using the statistical analysis of the spectrally selected fluorescence radiation emitted by a laser-pumped dye-doped random medium. Water solution of Rhodamine 6G was applied as the doping fluorescent agent for the ensembles of the densely packed silica grains, which were pumped by the 532 nm radiation of a solid state laser. The spectrum of the mean path length for a random medium was reconstructed.

  18. Synthesis and characterization of gold graphene composite with dyes as model substrates for decolorization: A surfactant free laser ablation approach

    Science.gov (United States)

    Sai Siddhardha, R. S.; Lakshman Kumar, V.; Kaniyoor, Adarsh; Sai Muthukumar, V.; Ramaprabhu, S.; Podila, Ramakrishna; Rao, A. M.; Ramamurthy, Sai Sathish

    2014-12-01

    A facile surfactant free laser ablation mediated synthesis (LAMS) of gold-graphene composite is reported here. The material was characterized using transmission electron microscopy, field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, powdered X-ray diffraction, Raman spectroscopy, Zeta potential measurements and UV-Visible spectroscopic techniques. The as-synthesized gold-graphene composite was effectively utilized as catalyst for decolorization of 4 important textile and laser dyes. The integration of gold nanoparticles (AuNPs) with high surface area graphene has enhanced the catalytic activity of AuNPs. This enhanced activity is attributed to the synergistic interplay of pristine gold's electronic relay and π-π stacking of graphene with the dyes. This is evident when the Rhodamine B (RB) reduction rate of the composite is nearly twice faster than that of commercial citrate capped AuNPs of similar size. In case of Methylene blue (MB) the rate of reduction is 17,000 times faster than uncatalyzed reaction. This synthetic method opens door to laser ablation based fabrication of metal catalysts on graphene for improved performance without the aid of linkers and surfactants.

  19. Generation of a quasi-monoergetic proton beam from laser-irradiated submicron droplets

    Czech Academy of Sciences Publication Activity Database

    Ter-Avetisyan, Sargis; Ramakrishna, B.; Prasad, R.; Borghesi, M.; Nickles, P. V.; Steinke, S.; Schnürer, M.; Popov, K.I.; Ramunno, L.; Zmitrenko, N.V.; Bychenkov, V.Yu.

    2012-01-01

    Roč. 19, č. 7 (2012), "073112-1"-"073112-8" ISSN 1070-664X R&D Projects: GA MŠk ED1.1.00/02.0061 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061 Institutional support: RVO:68378271 Keywords : spray * protons * lasers Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.376, year: 2012 http://pop.aip.org/resource/1/phpaen/v19/i7/p073112_s1?isAuthorized=no

  20. Photodetection of early cancer by laser-induced fluorescence of a tumor-selective dye: apparatus design and realization

    Science.gov (United States)

    Wagnieres, Georges A.; Depeursinge, Christian D.; Monnier, Philippe; Savary, Jean-Francois; Cornaz, Piet F.; Chatelain, Andre; van den Bergh, Hubert

    1990-07-01

    An apparatus is designed and realized to detect "early" cancer at the surface of the hollow organs in the human body by endoscopic means. The tumor is localized by the laser induced fluorescence of a dye (HPD) which concentrates selectively in the neoplastic tissue after intravenous injection. Fluorescence contrast between the tumor and its normal surroundings is enhanced by subtracting the background autofluorescence which occurs in both types of tissue. This is done by means of 2-color digital images manipulation in real-time. Preliminary clinical tests of the apparatus demonstrated the detection of carcinoma in situ in the esophagus.

  1. Effects of early combinatorial treatment of autologous split-thickness skin grafts in red duroc pig model using pulsed dye laser and fractional CO2 laser.

    Science.gov (United States)

    Bailey, J Kevin; Blackstone, Britani N; DeBruler, Danielle M; Kim, Jayne Y; Baumann, Molly E; McFarland, Kevin L; Imeokparia, Folasade O; Supp, Dorothy M; Powell, Heather M

    2018-01-01

    The use of pulsed dye laser (PDL) and fractional CO 2 (FX CO 2 ) laser therapy to treat and/or prevent scarring following burn injury is becoming more widespread with a number of studies reporting reduction in scar erythema and pruritus following treatment with lasers. While the majority of studies report positive outcomes following PDL or FX CO 2 therapy, a number of studies have reported no benefit or worsening of the scar following treatment. The objective of this study was to directly compare the efficacy of PDL, FX CO 2 , and PDL + FX CO 2 laser therapy in reducing scarring post burn injury and autografting in a standardized animal model. Eight female red Duroc pigs (FRDP) received 4 standardized, 1 in. x 1 in. third degree burns that were excised and autografted. Wound sites were treated with PDL, FX CO 2 , or both at 4, 8, and 12 weeks post grafting. Grafts receiving no laser therapy served as controls. Scar appearance, morphology, size, and erythema were assessed and punch biopsies collected at weeks 4, 8, 12, and 16. At week 16, additional tissue was collected for biomechanical analyses and markers for inflammatory cytokines, extracellular matrix (ECM) proteins, re-epithelialization, pigmentation, and angiogenesis were quantified at all time points using qRT-PCR. Treatment with PDL, FX CO 2 , or PDL + FX CO 2 resulted in significantly less contraction versus skin graft only controls with no statistically significant difference among laser therapy groups. Scars treated with both PDL and FX CO 2 were visually more erythematous than other groups with a significant increase in redness between two and three standard deviations above normal skin redness. Scars treated with FX CO 2 were visually smoother and contained significantly fewer wrinkles. In addition, hyperpigmentation was significantly reduced in scars treated with FX CO 2 . The use of fractional carbon dioxide or pulsed dye laser therapy within 1 month of autografting significantly reduced scar

  2. Thermomechanical and Photophysical Properties of Crystal-Violet-Dye/H2O Based Dissolutions via the Pulsed Laser Photoacoustic Technique

    Directory of Open Access Journals (Sweden)

    Vicente Torres-Zúñiga

    2014-01-01

    Full Text Available Different thermoelastic parameters, for example, the acoustic attenuation and the speed of sound, are fundamental for instrumental calibration and quantitative characterization of organic-based dissolutions. In this work, these parameters as functions of the concentration of an organic dye (crystal-violet: CV in distillated water (H2O based dissolutions are investigated. The speed of sound was measured by the pulsed-laser photoacoustic technique (PLPA, which consists in the generation of acoustic-waves by the optical absorption of pulsed light in a given material (in this case a liquid sample. The thermally generated sound-waves traveling through a fluid are detected with two piezoelectric sensors separated by a known distance. An appropriate processing of the photoacoustic signals allows an adequate data analysis of the generated waves within the system, providing an accurate determination of the speed of sound as function of the dye-concentration. The acoustic attenuation was calculated based on the distance of the two PZT-microphones to an acoustic-source point and performing linear-fitting of the experimental data (RMS-amplitudes as function of the dye-concentration. An important advantage of the PLPA-method is that it can be implemented with poor or null optical transmitting materials permitting the characterization of the mechanical and concentration/aggregate properties of dissolved organic compounds.

  3. Rapid fabrication of mesoporous TiO2 thin films by pulsed fibre laser for dye sensitized solar cells

    Science.gov (United States)

    Hadi, Aseel; Alhabradi, Mansour; Chen, Qian; Liu, Hong; Guo, Wei; Curioni, Michele; Cernik, Robert; Liu, Zhu

    2018-01-01

    In this paper we demonstrate for the first time that a fibre laser with a wavelength of 1070 nm and a pulse width of milliseconds can be applied to generate mesoporous nanocrystalline (nc) TiO2 thin films on ITO coated glass in ambient atmosphere, by complete vaporisation of organic binder and inter-connection of TiO2 nanoparticles, without thermally damaging the ITO layer and the glass substrate. The fabrication of the mesoporous TiO2 thin films was achieved by stationary laser beam irradiation of 1 min. The dye sensitized solar cell (DSSC) with the laser-sintered TiO2 photoanode reached higher power conversion efficiency (PCE) of 3.20% for the TiO2 film thickness of 6 μm compared with 2.99% for the furnace-sintered. Electrochemical impedance spectroscopy studies revealed that the laser sintering under the optimised condition effectively decreased charge transfer resistance and increased electron lifetime of the TiO2 thin films. The use of the fibre laser with over 40% wall-plug efficiency offers an economically-feasible, industrial viable solution to the major challenge of rapid fabrication of large scale, mass production of mesoporous metal oxide thin film based solar energy systems, potentially for perovskite and monolithic tandem solar cells, in the future.

  4. Microlens fabrication by replica molding of frozen laser-printed droplets

    Science.gov (United States)

    Surdo, Salvatore; Diaspro, Alberto; Duocastella, Martí

    2017-10-01

    In this work, we synergistically combine laser-induced forward transfer (LIFT) and replica molding for the fabrication of microlenses with control of their geometry and size independent of the material or substrate used. Our approach is based on a multistep process in which liquid microdroplets of an aqueous solution are first printed on a substrate by LIFT. Following a freezing step, the microdroplets are used as a master to fabricate a polydimethylsiloxane (PDMS) mold. A subsequent replica molding step enables the creation of microlenses and microlens arrays on arbitrary selected substrates and by using different curable polymers. Thus, our method combines the rapid fabrication capabilities of LIFT and the perfectively smooth surface quality of the generated microdroplets, with the advantages of replica molding in terms of parallelization and materials flexibility. We demonstrate our strategy by generating microlenses of different photocurable polymers and by characterizing their optical and morphological properties.

  5. Investigation on cone jetting regimes of liquid droplets subjected to pyroelectric fields induced by laser blasts

    Science.gov (United States)

    Gennari, Oriella; Battista, Luigi; Silva, Benjamin; Grilli, Simonetta; Miccio, Lisa; Vespini, Veronica; Coppola, Sara; Orlando, Pierangelo; Aprin, Laurent; Slangen, Pierre; Ferraro, Pietro

    2015-02-01

    Electrical conductivity and viscosity play a major role in the tip jetting behaviour of liquids subjected to electrohydrodynamic (EHD) forces, thus influencing significantly the printing performance. Recently, we developed a nozzle- and electrode-free pyro-EHD system as a versatile alternative to conventional EHD configurations and we demonstrated different applications, including inkjet printing and three-dimensional lithography. However, only dielectric fluids have been used in all of those applications. Here, we present an experimental characterization of the pyro-EHD jetting regimes, induced by laser blasts, of sessile drops in case of dielectric and conductive liquids in order to extend the applicability of the system to a wider variety of fields including biochemistry and biotechnology where conductive aqueous solutions are typically used.

  6. Excimer laser produced plasmas in copper wire targets and water droplets

    Science.gov (United States)

    Song, Kyo-Dong; Alexander, D. R.

    1994-01-01

    Elastically scattered incident radiation (ESIR) from a copper wire target illuminated by a KrF laser pulse at lambda = 248 nm shows a dinstinct two-peak structure which is dependent on the incident energy. The time required to reach the critical electron density (n(sub c) approximately = 1.8 x 10(exp 22) electrons/cu cm) is estimated at 11 ns based on experimental results. Detailed ESIR characteristics for water have been reported previously by the authors. Initiation of the broadband emission for copper plasma begins at 6.5 +/- 1.45 ns after the arrival of the laser pulse. However, the broadband emission occurs at 11 +/- 0.36 ns for water. For a diatomic substance such as water, the electron energy rapidly dissipates due to dissociation of water molecules, which is absent in a monatomic species such as copper. When the energy falls below the excitation energy of the lowest electron state for water, it becomes a subexcitation electron. Lifetimes of the subexcited electrons to the vibrational states are estimated to be of the order of 10(exp -9) s. In addition, the ionization potential of copper (440-530 nm) is approximately 6 eV, which is about two times smaller than the 13 eV ionization potential reported for water. The higher ionization potential contributes to the longer observed delay time for plasma formation in water. After initiation, a longer time is required for copper plasma to reach its peak value. This time delay in reaching the maximum intensity is attributed to the energy loss during the interband transition in copper.

  7. Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser

    Science.gov (United States)

    Chu, Zhiping; Wilkerson, Thomas D.; Singh, Upendra N.

    1993-01-01

    We report water-vapor absorption line measurements that are made by using the first Stokes radiation (930-982 nm) with HWHM 0.015/cm generated by a narrow-linewidth, tunable dye laser. Forty-five absorption line strengths are measured with an uncertainty of 6 percent and among them are fourteen strong lines that are compared with previous measurements for the assessment of spectral purity of the light source. Thirty air-broadened linewidths are measured with 8 percent uncertainty at ambient atmospheric pressure with an average of 0.101/cm. The lines are selected for the purpose of temperature-sensitive or temperature-insensitive lidar measurements. Results for these line strengths and linewidths are corrected for broadband radiation and finite laser linewidth broadening effects and compared with the high-resolution transmission molecular absorption.

  8. Biostimulative effects of Nd:YAG Q-switch dye on normal human fibroblast cultures: study of a new chemosensitizing agent for the Nd:YAG laser

    International Nuclear Information System (INIS)

    Castro, D.J.; Saxton, R.E.; Fetterman, H.R.; Castro, D.J.; Ward, P.H.

    1987-01-01

    Kodak Q-switch II is a new chemical with an absorption maxima at 1051 nm, designed to be used as an Nd:YAG dye laser. The potential for this dye as a new chemosensitizing agent in the treatment of connective tissue diseases and wound healing with low energy Nd:YAG laser was examined. Two normal fibroblast cell lines were tested for sensitivity to various levels of this dye in vitro. These cells were exposed to Q-switch II dye at concentrations of 0.01, 0.1, 1, 10, 50, and 100 micrograms/ml for 1 and 24 hours. Cell viability was assessed by the trypan blue exclusion test. Cell duplication and DNA synthesis were measured by the incorporation of [ 3 H]-thymidine at 6 and 24 hours postexposure to Q-switch II dye. At concentrations up to 10 micrograms/ml, both cell lines tested showed no changes in cell viability. However, at concentrations equal or higher than 50 micrograms/ml, more than 40% of the fibroblasts incorporated trypan blue after 24 hours of exposure to this dye, indicating significant cell destruction. The results indicate that Q-switch II dye is nontoxic to normal human fibroblast cultures and showed significant biostimulative effects on cell duplication at concentrations equal to or lower than 10 micrograms/ml. Further studies will be required to determine the usefulness of Q-switch II dye as a new photochemosensitizing agent for potential biostimulation of wound healing and/or treatment of connective tissue diseases with the Nd:YAG laser (near infrared, 1060 nm) at nonthermal levels of energies

  9. Flexible dye-sensitized solar cell fabricated on plastic substrate by laser-detachment and press method

    International Nuclear Information System (INIS)

    Kim, Choonghoe; Kim, Seongsu; Lee, Myeongkyu

    2013-01-01

    This report shows that flexible dye-sensitized solar cell can be fabricated by a laser-detachment and press method where the TiO 2 electrode typically sintered on glass source substrate is detached by a laser pulse and then is firmly adhered to the conductive plastic substrate by applying a high pressure. The cells fabricated by this process exhibited 36–43% smaller photocurrent and efficiency than the conventional glass cells with directly coated TiO 2 electrodes. It was attributed to the lowered dye coverage and electron diffusion length, both of which originate from the press-induced reduction of TiO 2 porosity. A maximum efficiency of 5.68% was obtained for the plastic cell. Bending of the electrode led to 20% loss of the current density and efficiency. However, no further performance degradation was observed even when the bending cycle was increased to 100, 300, and 500 times. This indicates that the bending-induced degradation of TiO 2 electrode on the plastic substrate takes place at the first bending.

  10. Comparison of various excitation and detection schemes for dye-doped polymeric whispering gallery mode micro-lasers.

    Science.gov (United States)

    Siegle, Tobias; Kellerer, Jonas; Bonenberger, Marielle; Krämmer, Sarah; Klusmann, Carolin; Müller, Marius; Kalt, Heinz

    2018-02-05

    We compare different excitation and collection configurations based on free-space optics and evanescently coupled tapered fibers for both lasing and fluorescence emission from dye-doped doped polymeric whispering gallery mode (WGM) micro-disk lasers. The focus of the comparison is on the lasing threshold and efficiency of light collection. With the aid of optical fibers, we localize the pump energy to the cavity-mode volume and reduce the necessary pump energy to achieve lasing by two orders of magnitude. When using fibers for detection, the collection efficiency is enhanced by four orders of magnitude compared to a free-space read-out perpendicular to the resonator plane. By enhancing the collection efficiency we are able to record a pronounced modulation of the dye fluorescence under continuous wave (cw) pumping conditions evoked by coupling to the WGMs. Alternatively to fibers as a collection tool, we present a read-out technique based on the detection of in-plane radiated light. We show that this method is especially beneficial in an aqueous environment as well as for size-reduced micro-lasers where radiation is strongly pronounced. Furthermore, we show that this technique allows for the assignment of transverse electric (TE) and transverse magnetic (TM) polarization to the observed fundamental modes in a water environment by performing polarization-dependent photoluminescence (PL) spectroscopy. We emphasize the importance of the polarization determination for sensing applications and verify expected differences in the bulk refractive index sensitivity for TE and TM WGMs experimentally.

  11. Plasma diagnosis by dye laser intracavity absorption: Final report for period January 1, 1982-May 31, 1986

    International Nuclear Information System (INIS)

    Brink, G.O.

    1986-05-01

    Dye laser intracavity absorption (ICA) has been studied as a potential diagnostic for plasma or neutral beam systems. For magnetic field measurements it is necessary to make Zeeman effect measurements on the resonance transition of atomic lithium on a millisecond time scale, or to make motional Stark Effect measurements on an injected fast atomic beam of hydrogen. To do this it may be necessary to sweep the dye laser in wavelength at a rapid rate so that the absorber can be sampled many times during the measurement. We have examined both of these possibilities during this contract. A rather detailed absorption spectrum of molecular hydrogen and deuterium arising in the 2c 3 Piu and other electronic states has been obtained and analyzed. This has provided new information on the types of molecular species that may be detected in a plasma by ICA, and may provide a basis for the application of ICA for the diagnosis of the edge plasma in a tokamak or in the end regions of a mirror machine

  12. Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique)

    International Nuclear Information System (INIS)

    Charalampous, Georgios; Hardalupas, Yannis

    2011-01-01

    The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60 deg. rather than the commonly used angle of 90 deg. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90 deg.) and for droplets with refractive indices around 1.4.

  13. A versatile bio-based material for efficiently removing toxic dyes, heavy metal ions and emulsified oil droplets from water simultaneously.

    Science.gov (United States)

    Li, Daikun; Li, Qing; Mao, Daoyong; Bai, Ningning; Dong, Hongzhou

    2017-12-01

    Developing versatile materials for effective water purification is significant for environment and water source protection. Herein, a versatile bio-based material (CH-PAA-T) was reported by simple thermal cross-linking chitosan and polyacrylic acid which exhibits excellent performances for removing insoluble oil, soluble toxic dyes and heavy metal ions from water, simultaneously. The adsorption capacities are 990.1mgg -1 for methylene blue (MB) and 135.9mgg -1 for Cu 2+ , which are higher than most of present advanced absorbents. The adsorption towards organic dyes possesses high selectivity which makes CH-PAA-T be able to efficiently separate dye mixtures. The stable superoleophobicity under water endows CH-PAA-T good performance to separate toluene-in-water emulsion stabilized by Tween 80. Moreover, CH-PAA-T can be recycled for 10 times with negligible reduction of efficiency. Such versatile bio-based material is a potential candidate for water purification. Copyright © 2017. Published by Elsevier Ltd.

  14. Characterisation of the light pulses of a cavity dumped dye laser pumped by a cw mode-locked and q-switched Nd:YAG laser

    International Nuclear Information System (INIS)

    Geist, P.; Heisel, F.; Martz, A.; Miehe, J.A.; Miller, R.J.D.

    1984-01-01

    The frequency doubled pulses (of 532 nm) obtained, with the help of a KTP crystal, from those delivered by either a continuous wave mode-locked (100 MHz) or mode-locked Q-switched (0-1 KHz) Nd: YAG laser, are analyzed by means of a streak camera, operating in synchroscan or triggered mode. In the step-by-step measurements the pulse stability, concerning form and amplitude, is shown. In addition, measurements effectuated with synchronously pumped and cavity dumped dye laser (Rhodamine 6G), controlled by a Pockels cell, allows the obtention of stable and reproducible single pulses of 30 ps duration, 10 μJ energy and 500Hz frequency [fr

  15. Enhancement of fluorescence, photo-physical parameters and laser performance of pyrromethene (PM597) laser dye by Ag nanoparticles in different media

    Energy Technology Data Exchange (ETDEWEB)

    Alhijry, Ibraheem A. [National Institute of Laser Enhanced Sciences, Cairo University, 12613 Giza (Egypt); Physics Department, Faculty of Science, Mansoura University, Mansoura (Egypt); Faculty of Education, Department of Physics, Hajjah University, Hajjah (Yemen); Gadallah, A.-S. [National Institute of Laser Enhanced Sciences, Cairo University, 12613 Giza (Egypt); Abdelkader, H.I. [Physics Department, Faculty of Science, Mansoura University, Mansoura (Egypt); Abou Kana, Maram T.H., E-mail: mabou202@niles.edu.eg [National Institute of Laser Enhanced Sciences, Cairo University, 12613 Giza (Egypt)

    2016-03-15

    The effect of surface plasmon resonance (SPR) of silver nanoparticles (Ag NPs), exposure to radiation, on the optical and photo-physical properties of pyrromethene (PM597) laser dye in liquid and solid media was assessed. 2-hydroxyethyl methacrylate was used as homo-monomer and homo-polymer, while 2-hydroxyethyl methacrylate / methyl methacrylate were used as co-monomer and co-polymer hosts. Ag NPs was prepared and confirmed its size by high resolution transmission electron microscope (HRTEM), UV/vis absorption spectroscopy and also, theoretically by using Mie theory. The molar concentration of prepared NPs was C=3.39×10{sup −9} mol/L. 40% C (1.356×10{sup −9} mol/L) Ag NPs was found to have the optimum distance with (1×10{sup −4} mol/L PM597 in liquid medium and 1×10{sup −3} mol/L PM597 in solid medium) dye molecules according to Metal Enhancement Fluorescence (MEF) model. [40% C Ag NPs: 1×10{sup −3} mol/L PM597] complex samples had 3.12 cm{sup −1} and 3.89 cm{sup −1} gain values in homo-and co-polymer media, while parent PM597 dye had 2.5 cm{sup −1} and 3.45 cm{sup −1} gain values. Also, amplified spontaneous emission (ASE) value of complex samples was 0.455% and 0.538% in case of homo- and co-polymer respectively. While it was 0.4% and 0.457% in case of parent PM597 dye in the same sequent media. Finally, photo-stabilities of complex samples had higher values in co-monomer and co-polymer hosts compared with respect to their stabilities in homo-monomer and homo-polymer hosts.

  16. Enhancement of fluorescence, photo-physical parameters and laser performance of pyrromethene (PM597) laser dye by Ag nanoparticles in different media

    International Nuclear Information System (INIS)

    Alhijry, Ibraheem A.; Gadallah, A.-S.; Abdelkader, H.I.; Abou Kana, Maram T.H.

    2016-01-01

    The effect of surface plasmon resonance (SPR) of silver nanoparticles (Ag NPs), exposure to radiation, on the optical and photo-physical properties of pyrromethene (PM597) laser dye in liquid and solid media was assessed. 2-hydroxyethyl methacrylate was used as homo-monomer and homo-polymer, while 2-hydroxyethyl methacrylate / methyl methacrylate were used as co-monomer and co-polymer hosts. Ag NPs was prepared and confirmed its size by high resolution transmission electron microscope (HRTEM), UV/vis absorption spectroscopy and also, theoretically by using Mie theory. The molar concentration of prepared NPs was C=3.39×10 −9 mol/L. 40% C (1.356×10 −9 mol/L) Ag NPs was found to have the optimum distance with (1×10 −4 mol/L PM597 in liquid medium and 1×10 −3 mol/L PM597 in solid medium) dye molecules according to Metal Enhancement Fluorescence (MEF) model. [40% C Ag NPs: 1×10 −3 mol/L PM597] complex samples had 3.12 cm −1 and 3.89 cm −1 gain values in homo-and co-polymer media, while parent PM597 dye had 2.5 cm −1 and 3.45 cm −1 gain values. Also, amplified spontaneous emission (ASE) value of complex samples was 0.455% and 0.538% in case of homo- and co-polymer respectively. While it was 0.4% and 0.457% in case of parent PM597 dye in the same sequent media. Finally, photo-stabilities of complex samples had higher values in co-monomer and co-polymer hosts compared with respect to their stabilities in homo-monomer and homo-polymer hosts.

  17. A new method to induce transitions in muonic atoms using a high-power tunable dye laser coupled to a stopping muon beam

    CERN Document Server

    Bertin, A; Duclos, J; Gastaldi, Ugo; Gorini, G; Neri, G; Picard, J; Pitzurra, O; Placci, A; Polacco, E; Stefanini, G; Torelli, G; Vitale, A; Zavattini, E

    1974-01-01

    An apparatus is described in which a ruby-pumped dye laser is used to induce transitions from the 2S to the 2P levels of the muonic ion ( mu He)/sup +/. The dye laser supplies infra-red radiation pulses in the wavelengths (8040-8180) AA, at typical repetition rates of 1 pulse every 4 s, with an energy release per pulse of 300 mJ for 1.2 J pumping energy. A special synchronization procedure is followed to trigger the laser in close coupling with the incoming muon beam which is stopped in a helium target at pressures between 40 and 50 atm. The other performances of the device are fully discussed with reference both to the laser facility and to the special high-pressure helium target. (23 refs).

  18. Intravenous injection of artificial red cells and subsequent dye laser irradiation causes deep vessel impairment in an animal model of port-wine stain.

    Science.gov (United States)

    Rikihisa, Naoaki; Tominaga, Mai; Watanabe, Shoji; Mitsukawa, Nobuyuki; Saito, Yoshiaki; Sakai, Hiromi

    2018-03-15

    Our previous study proposed using artificial blood cells (hemoglobin vesicles, Hb-Vs) as photosensitizers in dye laser treatment for port-wine stains (PWSs). Dye laser photons are absorbed by red blood cells (RBCs) and hemoglobin (Hb) mixture, which potentially produce more heat and photocoagulation and effectively destroy endothelial cells. Hb-Vs combination therapy will improve clinical outcomes of dye laser treatment for PWSs because very small vessels do not contain sufficient RBCs and they are poor absorbers/heaters of lasers. In the present study, we analyzed the relationship between vessel depth from the skin surface and vessel distraction through dye laser irradiation following intravenous Hb-Vs injection using a chicken wattle model. Hb-Vs were administered and chicken wattles underwent high-energy irradiation at energy higher than in the previous experiments. Hb-Vs location in the vessel lumen was identified to explain its photosensitizer effect using human Hb immunostaining of the irradiated wattles. Laser irradiation with Hb-Vs can effectively destroy deep vessels in animal models. Hb-Vs tend to flow in the marginal zone of both small and large vessels. Increasing laser power combined with Hb-Vs injection contributed for deep vessel impairment because of the synergetic effect of both methods. Newly added Hb tended to flow near the target endothelial cells of the laser treatment. In Hb-Vs and RBC mixture, heat transfer to endothelial cells from absorbers/heater may increase. Hb-Vs function as photosensitizers to destroy deep vessels within a restricted distance that the photon can reach.

  19. Production of spectrally reconstructed uv-radiation by means of a nonlinear conversion of the generation frequency of a dye laser with lamp pumping

    Energy Technology Data Exchange (ETDEWEB)

    Anufrik, S S; Mostovnikov, V A; Rubinov, A N

    1976-03-01

    By doubling the generation frequency of an organic dye laser with lamp pumping, radiation is obtained in the spectral region of 285 to 305 nm. Depending on the mode of operation of a given laser the spectral width of the uv-radiation was 0.5 or approximately 0.003 nm. The maximum energy of second harmonic pulses was equal to approximately 0.01 J. (SJR)

  20. Multimode laser emission from dye-doped hollow polymer optical fibre

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... Dye-doped polymer optical fibre preforms were fabricated by the controlled polymeriza- tion of Rh B-doped methyl methacrylate (MMA). Hole in the preform can be achieved by placing a teflon rod on the centre of the glass tube during the polymerization. Final fibre structure with required diameter was ...

  1. Double Pass 595?nm pulsed dye laser at a 6 minute interval for the treatment of port-wine stains is not more effective than single pass

    NARCIS (Netherlands)

    Peters, M. A. D.; van Drooge, A. M.; Wolkerstorfer, A.; van Gemert, M. J. C.; van der Veen, J. P. W.; Bos, J. D.; Beek, J. F.

    2012-01-01

    Background Pulsed dye laser (PDL) is the first choice for treatment of port wine stains (PWS). However, outcome is highly variable and only a few patients achieve complete clearance. The objective of the study was to compare efficacy and safety of single pass PDL with double pass PDL at a 6 minute

  2. Fluorescence, Decay Time, and Structural Change of Laser Dye Cresyl Violet in Solution due to Microwave Irradiation at GSM 900/1800 Mobile Phone Frequencies

    Directory of Open Access Journals (Sweden)

    Fuat Bayrakceken

    2012-01-01

    Full Text Available Microwave irradiation at GSM 900/1800 MHz mobile phone frequencies affects the electronic structure of cresyl violet in solution. These changes are important because laser-dye cresyl violet strongly bonds to DNA- and RNA-rich cell compounds in nerve tissues. The irradiation effects on the electronic structure of cresyl violet and its fluorescence data were all obtained experimentally at room temperature. For most laser dyes, this is not a trivial task because laser dye molecules possess a relatively complex structure. They usually consist of an extended system of conjugated double or aromatic π-bonds with attached auxochromic (electron donating groups shifting the absorption band further towards longer wavelength. Because of the intrinsically high degree of conjugation, the vibrational modes of the molecular units couple strongly with each other. We found that the fluorescence quantum yield was increased from to due to intramolecular energy hopping of cresyl violet in solution which is exposed to microwave irradiation at mobile phone frequencies, and the photonic product cannot be used as a laser dye anymore.

  3. Absolute transition probabilities in the NeI 3p-3s fine structure by beam-gas-dye laser spectroscopy

    International Nuclear Information System (INIS)

    Hartmetz, P.; Schmoranzer, H.

    1983-01-01

    The beam-gas-dye laser two-step excitation technique is further developed and applied to the direct measurement of absolute atomic transition probabilities in the NeI 3p-3s fine-structure transition array with a maximum experimental error of 5%. (orig.)

  4. Effect of the timing of treatment of port-wine stains with the flash-lamp-pumped pulsed-dye laser

    NARCIS (Netherlands)

    van der Horst, C. M.; Koster, P. H.; de Borgie, C. A.; Bossuyt, P. M.; van Gemert, M. J.

    1998-01-01

    BACKGROUND: Port-wine stains can be treated with a flash-lamp-pumped pulsed-dye laser, but it is uncertain whether this treatment is more effective if administered early in life, when the skin is thinner and the lesion is smaller. METHODS: We prospectively studied 100 patients with a previously

  5. Histologic evaluation of skin damage after overlapping and nonoverlapping flashlamp pumped pulsed dye laser pulses: A study on normal human skin as a model for port wine stains

    NARCIS (Netherlands)

    Koster, P. H.; van der Horst, C. M.; van Gemert, M. J.; van der Wal, A. C.

    2001-01-01

    BACKGROUND AND OBJECTIVE: In the treatment of port wine stains (PWS) with the flashlamp pumped pulsed dye laser (FPPDL), no consensus exists about overlapping of pulses. The advantage of overlapping pulses is homogeneous lightening of the PWS; the risk is redundant tissue damage. The aim of this

  6. Fluorescence from gaseous UF/sub 6/ excited by a near-UV dye laser. [Decay time,quenching rate,room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Benetti, P [Pavia Univ. (Italy); Cubeddu, R; Sacchi, C A; Svelto, O; Zaraga, F [Politecnico di Milano (Italy)

    1976-06-01

    Preliminary data are reported on the visible fluorescence of gaseous UF/sub 6/ excited by a dye laser at 374 nm. A decay time of 500 ns at p = 0 and a quenching rate of 5.7 x 10/sup -12/cm/sup 3/molec/sup -1/s/sup -1/ have been measured at room temperature.

  7. Combination of 595-nm pulsed dye laser, long-pulsed 755-nm alexandrite laser, and microdermabrasion treatment for keratosis pilaris: retrospective analysis of 26 Korean patients.

    Science.gov (United States)

    Lee, Sang Ju; Choi, Min Ju; Zheng, Zhenlong; Chung, Won Soon; Kim, Young Koo; Cho, Sung Bin

    2013-06-01

    Keratosis pilaris (KP) has beenpresented as small keratotic follicular papules with or without surrounding erythema. Various treatments with laser or light therapy have been used for the management of KP with various clinical outcomes. In the present study, we investigated the efficacy and safety of a combination therapy for KP. A total of 29 anatomical sites with KP in 26 patients were treated using a 595-nm pulsed dye laser (PDL) with nonpurpuragenic fluences, a long-pulsed 755-nm alexandrite laser, and microdermabrasion. Clinical improvement was assessed by comparing preand posttreatment clinical photographs and patient satisfaction rates. Evaluation of the clinical results three months after the treatments showed that 12 of the 29 anatomical sites (41.4%) demonstrated Grade 3 clinical improvement, ten (34.5%) had Grade 2 clinical improvement, four (13.8%) showed Grade 1 improvement, and three (10.3%) showed Grade 4 improvement. We observed that KP lesions improved not only in erythema and skin texture, but also in brownish dyschromias. Potential adverse events were not observed, except prolonged posttherapy scaling. Our observations demonstrate that combination therapy using a 595-nm PDL, a long-pulsed 755-nm alexandrite laser, and microdermabrasion can have a positive therapeutic effect on KP.

  8. Multi step FRET among three laser dyes Pyrene, Acriflavine and Rhodamine B

    International Nuclear Information System (INIS)

    Saha, Jaba; Dey, Dibyendu; Roy, Arpan Datta; Bhattacharjee, D.; Hussain, Syed Arshad

    2016-01-01

    Fluorescence Resonance Energy Transfer (FRET) system using three dyes has been demonstrated. It has been observed that multi step energy transfer occurred from Pyrene to Rhodamine B via Acriflavine. Here Acriflavine acts as an antenna to receive energy from Pyrene and transfer the same to Rhodamine B. This multi step FRET system is advantageous compared to the conventional FRET as this can be used to study molecular level interaction beyond conventional FRET distance (1–10 nm) as well as studying multi-branched macromolecules. The introduction of clay enhances the FRET efficiencies among the dye pair, which is an advantage to make the multi step system more useful. Similar approach can be used for increasing FRET efficiencies by using other dyes. - Highlights: • Multi-step FRET occurred from Pyrene (Py) to Rhodamine B (RhB) via Acriflavine (Acf). • Acf acts as an antenna to receive energy from Py and to transfer energy to RhB. • Multi-step FRET can be used to study molecular level interaction beyond 1–10 nm. • Incorporation of nanoclay laponite enhances the energy transfer efficiency.

  9. Recent advance to 3 × 10(-5) rad near diffraction-limited beam divergence of dye laser with transverse-discharge flash-lamp pumping.

    Science.gov (United States)

    Trusov, K K

    1994-02-20

    A new experimental setup of a Rhodamine 6G dye laser with a transverse-discharge flash-lamp-pumping system is presented. It differs from a previous setup [Sov. J. Quantum Electron. 16, 468-471 (1989)] in that it has a larger laser beam aperture (32 mm) and higher pumping energy (1 kJ), which made it possible to test the scalability and reach near diffraction-limited laser beam divergence of 3 × 10(-5) rad FWHM at beam energy 1.4 J. The effect of spectral dispersion in the active medium and of other optical elements on the beam divergence is also discussed.

  10. Multimode laser emission from dye-doped hollow polymer optical fibre

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... Fibre lasers; optical microcavities; whispering gallery modes. ... A blueshift in the mode structure was observed with decrease in fibre diameter leading to wide range tunability of the laser emission. ... International School of Photonics, Cochin University of Science & Technology, Cochin 682 022, India ...

  11. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    Science.gov (United States)

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Two 5 × 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Indocyanine green dye

  12. Microjet-assisted dye-enhanced diode laser ablation of cartilaginous tissue

    Science.gov (United States)

    Pohl, John; Bell, Brent A.; Motamedi, Massoud; Frederickson, Chris J.; Wallace, David B.; Hayes, Donald J.; Cowan, Daniel

    1994-08-01

    Recent studies have established clinical application of laser ablation of cartilaginous tissue. The goal of this study was to investigate removal of cartilaginous tissue using diode laser. To enhance the interaction of laser light with tissue, improve the ablation efficiency and localize the extent of laser-induced thermal damage in surrounding tissue, we studied the use of a novel delivery system developed by MicroFab Technologies to dispense a known amount of Indocyanine Green (ICG) with a high spatial resolution to alter the optical properties of the tissue in a controlled fashion. Canine intervertebral disks were harvested and used within eight hours after collection. One hundred forty nL of ICG was topically applied to both annulus and nucleus at the desired location with the MicroJet prior to each irradiation. Fiber catheters (600 micrometers ) were used and positioned to irradiate the tissue with a 0.8 mm spot size. Laser powers of 3 - 10 W (Diomed, 810 nm) were used to irradiate the tissue with ten pulses (200 - 500 msec). Discs not stained with ICG were irradiated as control samples. Efficient tissue ablation (80 - 300 micrometers /pulse) was observed using ICG to enhance light absorption and confine thermal damage while there was no observable ablation in control studied. The extent of tissue damage observed microscopically was limited to 50 - 100 micrometers . The diode laser/Microjet combination showed promise for applications involving removal of cartilaginous tissue. This procedure can be performed using a low power compact diode laser, is efficient, and potentially more economical compared to procedures using conventional lasers.

  13. Synthesis and analysis of nickel dithiolene dyes in a nematic liquid crystal host. 1998 summer research program for high school juniors at the University of Rochester's Laboratory for Laser Energetics. Student research reports

    International Nuclear Information System (INIS)

    Lippa, I.

    1999-03-01

    The Liquid Crystal Point Diffraction Interferometer (LCPDI) can be employed to evaluate the Omega Laser system for optimum firing capabilities. This device utilizes a nickel dithiolene infrared absorbing liquid crystal dye dissolved in a liquid crystal host medium (Merck E7). Three nickel dithiolene dyes were characterized for both their solubility in the E7 host and their infrared spectral absorption

  14. Facile synthesis of silicon carbide-titanium dioxide semiconducting nanocomposite using pulsed laser ablation technique and its performance in photovoltaic dye sensitized solar cell and photocatalytic water purification

    Energy Technology Data Exchange (ETDEWEB)

    Gondal, M.A., E-mail: magondal@kfupm.edu.sa [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Ilyas, A.M. [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Baig, Umair [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Center of Excellence for Scientific Research Collaboration with MIT, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2016-08-15

    Highlights: • SiC–TiO{sub 2} semiconducting nanocomposites synthesized by nanosecond PLAL technique. • Synthesized nanocomposites were morphologically and optically characterized. • Nanocomposites were applied for the photocatalytic degradation of toxic organic dye. • Photovoltaic performance was investigated in dye sensitized solar cell. - Abstract: Separation of photo-generated charge carriers (electron and holes) is a major approach to improve the photovoltaic and photocatalytic performance of metal oxide semiconductors. For harsh environment like high temperature applications, ceramic like silicon carbide is very prominent. In this work, 10%, 20% and 40% by weight of pre-oxidized silicon carbide was coupled with titanium dioxide (TiO{sub 2}) to form nanocomposite semiconductor via elegant pulsed laser ablation in liquid technique using second harmonic 532 nm wavelength of neodymium-doped yttrium aluminium garnet (Nd-YAG) laser. In addition, the effect of silicon carbide concentration on the performance of silicon carbide-titanium dioxide nanocomposite as photo-anode in dye sensitized solar cell and as photocatalyst in photodegradation of methyl orange dye in water was also studied. The result obtained shows that photo-conversion efficiency of the dye sensitized solar cell was improved from 0.6% to 1.65% and the percentage of methyl orange dye removed was enhanced from 22% to 77% at 24 min under ultraviolet–visible solar spectrum in the nanocomposite with 10% weight of silicon carbide. This remarkable performance enhancement could be due to the improvement in electron transfer phenomenon by the presence of silicon carbide on titanium dioxide.

  15. Optimal dye concentration and irradiance for laser-assisted vascular anastomosis.

    Science.gov (United States)

    Ren, Zhen; Xie, Hua; Lagerquist, Kathryn A; Burke, Allen; Prahl, Scott; Gregory, Kenton W; Furnary, Anthony P

    2004-04-01

    This investigation was done in order to find optimal indocyanine green (ICG) concentration and energy irradiance in laser vascular welding. Many studies have shown that laser tissue welding with albumin solder/ICG may be an effective technique in surgical reconstruction. However, there are few reports regarding optimal laser settings and concentrations of ICG within the albumin solder in laser-assisted vascular anastomosis. Porcine carotid artery strips (n = 120) were welded in end-to-end by diode laser with 50% albumin solder of 0.01, 0.1, and 1.0 mM ICG at irradiance of 27.7, 56.7, and 76.9 W/cm(2), respectively. Temperature was measured by inserting thermocouples outside and inside the vessel. Tensile strength and histology were studied. Temperature and strength of the anastomosis significantly decreased (all p < 0.05) with increasing ICG concentration at 56.7 W/cm(2). Histological study showed minimal thermal injury limited to adventitia and no appreciable difference between all groups. ICG concentration within solder is the most important factor affecting both vascular temperature and tensile strength. The optimal balance between strength and minimal thermal injury may be achieved primarily at 56.7 W/cm(2) and 0.01 mM ICG.

  16. Estimation of ground and excited state dipole moment of laser dyes C504T and C521T using solvatochromic shifts of absorption and fluorescence spectra.

    Science.gov (United States)

    Basavaraja, Jana; Suresh Kumar, H M; Inamdar, S R; Wari, M N

    2016-02-05

    The absorption and fluorescence spectra of laser dyes: coumarin 504T (C504T) and coumarin 521T (C521T) have been recorded at room temperature in a series of non-polar and polar solvents. The spectra of these dyes showed bathochromic shift with increasing in solvent polarity indicating the involvement of π→π⁎ transition. Kamlet-Taft and Catalan solvent parameters were used to analyze the effect of solvents on C504T and C521T molecules. The study reveals that both general solute-solvent interactions and specific interactions are operative in these two systems. The ground state dipole moment was estimated using Guggenheim's method and also by quantum mechanical calculations. The solvatochromic data were used to determine the excited state dipole moment (μ(e)). It is observed that dipole moment value of excited state (μ(e)) is higher than that of the ground state in both the laser dyes indicating that these dyes are more polar in nature in the excited state than in the ground state. Copyright © 2015. Published by Elsevier B.V.

  17. Effect of conjugation length on nonlinear optical parameters of anthraquinone dyes investigated using He-Ne laser operating in CW mode

    Science.gov (United States)

    Pramodini, S.; Poornesh, P.

    2014-10-01

    We report the studies on third-order optical nonlinearity and optical limiting of anthraquinone dyes. Z-scan technique was employed to evaluate the nonlinear parameters such as nonlinear absorption coefficient βeff and nonlinear index of refraction n2. Continuous wave He-Ne laser was used as the source of excitation. The estimated values of βeff, n2 and χ(3) are of the order of 10-3 cm/W, 10-5 esu and 10-7 esu respectively. The presence of donor and acceptor groups in the structure results in increase in conjugation length. This resulted in the enhancement of nonlinear optical parameters values of the dye. Multiple diffraction rings were observed when the samples were exposed to laser beam due to thermal lensing. Dyes exhibited good optical limiting behavior under the experimental conditions. The results indicate that the dyes investigated here are materialise as candidates for photonics device applications such as optical power limiters.

  18. High-resolution absorption spectrum of the 61S0 → 63P1 transition in mercury with a Cw dye laser

    International Nuclear Information System (INIS)

    Crane, J.K.; Erbert, G.V.; Mostek, S.D.; Kerlin, R.C.; Paisner, J.A.

    1985-01-01

    Using a stabilized single-frequency commercial dye laser and an external cavity doubling crystal, we have measured the isotope shifts of mercury for the 6 1 S 0 → 6 3 P 1 transition with an accuracy of 4 MHz. We describe the method for generating single-frequency light at 2537 A and compare the results of our measurements of the isotope shifts with previous work. 7 refs., 5 figs., 1 tab

  19. Droplet Growth

    Science.gov (United States)

    Marder, Michael Paolo

    When a mixture of two materials, such as aluminum and tin, or alcohol and water, is cooled below a certain temperature, the two components begin to separate. If one component is dilute in the other, it may separate out in the form of small spheres, and these will begin to enlarge, depleting the supersaturated material around them. If the dynamics is sufficiently slow, thermodynamics gives one considerable information about how the droplets grow. Two types of experiment have explored this behavior and given puzzling results. Nucleation experiments measure the rate at which droplets initially appear from a seemingly homogeneous mixture. Near the critical point in binary liquids, experiments conducted in the 1960's and early 1970's showed that nucleation was vastly slower than theory seemed to predict. The resolution of this problem arises by considering in detail the dynamics of growing droplets and comparing it with what experiments actually measure. Here will be presented a more detailed comparison of theory and experiment than has before been completed, obtaining satisfactory agreement with no free parameters needed. A second type of experiment measures droplet size distributions after long times. In the late stage, droplets compete with each other for material, a few growing at the expense of others. A theory first proposed by Lifshitz and Slyozov claims that this distribution, properly scaled, should be universal, and independent of properties of materials. Yet experimental measurements consistently find distributions that are more broad and squat than the theory would predict. Satisfactory agreement with experiment can be achieved by considering two points. First, one must study the complete time development of droplet size distributions, to understand when the asymptotic regime obtains. Second, droplet size distributions are spread by correlations between droplets. If one finds a small droplet, it is small because large droplets nearby are competing with it

  20. Studies on the optogalvanic effect and isotope-selective excitation of ytterbium in a hollow cathode discharge lamp using a pulsed dye laser.

    Science.gov (United States)

    Kumar, Pankaj; Kumar, Jitendra; Prakash, Om; Saini, Vinod K; Dixit, Sudhir K; Nakhe, Shankar V

    2013-09-01

    This paper presents studies on the pulsed optogalvanic effect and isotope-selective excitation of Yb 555.648 nm (0 cm(-1) → 17 992.007 cm(-1)) and 581.067 nm (17 992.007 cm(-1) → 35 196.98 cm(-1)) transitions, in a Yb/Ne hollow cathode lamp. The Yb atoms were excited by narrow linewidth (500-1000 MHz) Rh110 and Rh6G dye based pulsed lasers. Optogalvanic signal inversion for ground state transition at 555.648 nm was observed beyond a hollow cathode discharge current of 8.5 mA, in contrast to normal optogalvanic signal at 581.067 nm up to maximum current of 14 mA. The isotope-selective excitation studies of Yb were carried out by recording Doppler limited optogalvanic signals as a function of dye laser wavelength. For the 581.067 nm transition, three even isotopes, (172)Yb, (174)Yb, and (176)Yb, and one odd isotope, (171)Yb, were clearly resolved. These data were compared with selective isotope excitation by 10 MHz linewidth continuous-wave dye laser. For 555.648 nm transition, isotopes were not clearly resolved, although isotope peaks of low modulation were observed.

  1. TiO{sub 2} nanocrystals synthesized by laser pyrolysis for the up-scaling of efficient solid-state dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Melhem, Hussein; Boucharef, Mourad; Di Bin, Catherine; Ratier, Bernard; Boucle, Johann [XLIM UMR 6172 Universite de Limoges/CNRS, Limoges Cedex (France); Simon, Pardis; Leconte, Yann; Herlin-Boime, Nathalie [IRAMIS/SPAM/LFP, CEA-CNRS URA 2453, CEA Saclay, Gif sur Yvette (France); Beouch, Layla; Goubard, Fabrice [Laboratoire de Physico-Chimie des Polymeres et des Interfaces (LPPI), Federation Institut des Materiaux (FD 4122), Universite de Cergy-Pontoise (France)

    2011-10-15

    A crucial issue regarding emerging nanotechnologies remains the up-scaling of new functional nanostructured materials towards their implementation in high performance applications on a large scale. In this context, we demonstrate high efficiency solid-state dye-sensitized solar cells prepared from new porous TiO{sub 2} photoanodes based on laser pyrolysis nanocrystals. This strategy exploits a reduced number of processing steps as well as non-toxic chemical compounds to demonstrate highly porous TiO{sub 2} films. The possibility to easily tune the TiO{sub 2} nanocrystal physical properties allows us to demonstrate all solid-state dye-sensitized devices based on a commercial benchmark materials (organic indoline dye and molecular hole transporter) presenting state-of-the-art performance comparable with reference devices based on a commercial TiO{sub 2} paste. In particular, a drastic improvement in pore infiltration, which is found to balance a relatively lower surface area compared to the reference electrode, is evidenced using laser-synthesized nanocrystals resulting in an improved short-circuit current density under full sunlight. Transient photovoltage decay measurements suggest that charge recombination kinetics still limit device performance. However, the proposed strategy emphasizes the potentialities of the laser pyrolysis technique for up-scaling nanoporous TiO{sub 2} electrodes for various applications, especially for solar energy conversion. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. The use of vitamins as tracer dyes for laser-induced fluorescence in liquid flow applications

    Science.gov (United States)

    Zähringer, Katharina

    2014-04-01

    Tracers commonly used in experimental flow studies are mostly nocuous to the environment and human health. Particularly, in large flow installations, this can become a problem. In this study, a solution of this problem is presented, based on using water-soluble vitamins. Five of them are examined here for their applicability in flow studies. Vitamins B2 and B6 turned out to be the most promising candidates, and the dependency of their fluorescence intensity on parameters like concentration, laser energy, temperature, and pH are determined for two commonly used laser excitation wavelengths (532, 355 nm). Two examples of application in a static mixer and a spray flow are shown and demonstrate the applicability of the vitamin tracers.

  3. Laser/fluorescent dye flow visualization technique developed for system component thermal hydraulic studies

    International Nuclear Information System (INIS)

    Oras, J.J.; Kasza, K.E.

    1988-01-01

    A novel laser flow visualization technique is presented together with examples of its use in visualizing complex flow patterns and plans for its further development. This technique has been successfully used to study (1) the flow in a horizontal pipe subject to temperature transients, to view the formation and breakup of thermally stratified flow and to determine instantaneous velocity distributions in the same flow at various axial locations; (2) the discharge of a stratified pipe flow into a plenum exhibiting a periodic vortex pattern; and (3) the thermal-buoyancy-induced flow channeling on the shell side of a heat exchanger with glass tubes and shell. This application of the technique to heat exchangers is unique. The flow patterns deep within a large tube bundle can be studied under steady or transient conditions. This laser flow visualization technique constitutes a very powerful tool for studying single or multiphase flows in complex thermal system components

  4. Linearly and circularly polarized laser photoinduced molecular order in azo dye doped polymer films

    Directory of Open Access Journals (Sweden)

    Saad Bendaoud

    2017-01-01

    Full Text Available Photo-induced behavior of Azo Disperse one (AZD1 doped Poly(Methyl MethAcrylate (PMMA using both linear and circular polarized light is studied. The anisotropy is not erased by the circular polarization light. The circular polarization light combined with relatively long lifetime of the cis state in azo dye doped polymers activate all transverse directions of the angular hole burning through the spot in the film inducing anisotropy. Under circular polarized light, there is no orientation perpendicularly to the helex described by the rotating electric field vector, trans molecules reorients in the propagation direction of the pump beam. The polarization state of the probe beam after propagation through the pumped spot depends strongly on the angle of incidence of both pump and probe beams on the input face. In the case where circular polarized pump and probe beams are under the same angle of incidence, the probe beam “sees” anisotropic film as if it is isotropic. Results of this work shows the possibility to reorient azobenzene-type molecules in two orthogonal directions using alternately linearly and circularly polarized beams.

  5. Enhancing the photovoltaic performance of bulk heterojunction polymer solar cells by adding Rhodamine B laser dye as co-sensitizer.

    Science.gov (United States)

    Kazemifard, Sholeh; Naji, Leila; Afshar Taromi, Faramarz

    2018-04-01

    Ternary blend (TB) strategy has been considered as an effective method to enhance the photovoltaic performance of bulk heterojunction (BHJ) polymer solar cells (PSCs). Here, we report on TB-based PSCs containing two donor materials; poly-3-hexylthiophene (P3HT) and Rhodamine B (RhB) laser organic dye, and [6,6]-phenyl C 61 butyric acid methyl ester (PC 61 BM) as an acceptor. The influence of RhB weight percentage and injection volume was extensively studied. To gain insight into the influences of RhB on the photovoltaic performance of PSCs, physicochemical and optical properties of TBs were compared with those of BHJ binary blend as a standard. RhB broadened the light absorption properties of the active layer and played a bridging role between P3HT and PC 61 BM. The PCE and short-circuit current density (Jsc) of the optimized TB-based PSCs comprising of 0.5 wt% RhB reached 5% and 12.12 mA/cm 2 , respectively. Compared to BHJ standard cell, the PCE and the generated current was improved by two orders of magnitude due to higher photon harvest of the active layer, cascade energy level structure of TB components and a considerable decrease in the charge carrier recombination. The results suggest that RhB can be considered as an effective material for application in PSCs to attain high photovoltaic performance. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Laser synthesized super-hydrophobic conducting carbon with broccoli-type morphology as a counter-electrode for dye sensitized solar cells

    Science.gov (United States)

    Gokhale, Rohan; Agarkar, Shruti; Debgupta, Joyashish; Shinde, Deodatta; Lefez, Benoit; Banerjee, Abhik; Jog, Jyoti; More, Mahendra; Hannoyer, Beatrice; Ogale, Satishchandra

    2012-10-01

    A laser photochemical process is introduced to realize superhydrophobic conducting carbon coatings with broccoli-type hierarchical morphology for use as a metal-free counter electrode in a dye sensitized solar cell. The process involves pulsed excimer laser irradiation of a thin layer of liquid haloaromatic organic solvent o-dichlorobenzene (DCB). The coating reflects a carbon nanoparticle-self assembled and process-controlled morphology that yields solar to electric power conversion efficiency of 5.1% as opposed to 6.2% obtained with the conventional Pt-based electrode.A laser photochemical process is introduced to realize superhydrophobic conducting carbon coatings with broccoli-type hierarchical morphology for use as a metal-free counter electrode in a dye sensitized solar cell. The process involves pulsed excimer laser irradiation of a thin layer of liquid haloaromatic organic solvent o-dichlorobenzene (DCB). The coating reflects a carbon nanoparticle-self assembled and process-controlled morphology that yields solar to electric power conversion efficiency of 5.1% as opposed to 6.2% obtained with the conventional Pt-based electrode. Electronic supplementary information (ESI) available: Materials and equipment details, solar cell fabrication protocol, electrolyte spreading time measurement details, XPS spectra, electronic study, film adhesion test detailed analysis and field emission results. See DOI: 10.1039/c2nr32082g

  7. Stimulation of mitochondrial respiration induced by laser irradiation in the presence of rhodamine dyes

    International Nuclear Information System (INIS)

    Krasnikov, B.F.; Zorov, D.B.

    1996-01-01

    The effect of micromolar concentration of rhodamine 123 (methylrhodamine) and ethyl and amyl esters of unsubstituted rhodamine on oxygen consumption by rat liver mitochondria was studied under irradiation by an argon laser (488 and 514 nm). Irradiation of mitochondria in the presence of rhodamine stimulates their respiration. Light-induced stimulation of respiration is not inhibited by free radical scavenger ionol and by inhibitor of the permeability transition pore cyclosporine A. Stimulation of respiration by moderate doses of radiation is reversed in the dark. Increase in radiation dose resulted in only partial reversal of stimulated respiration in the dark. Rhodamine efficacy in stimulation of mitochondrial respiration depends on its structure (amyl > ethyl > methylrhodamine). 22 refs.; 4 figs

  8. Ablation of intervertebral discs in dogs using a MicroJet-assisted dye-enhanced injection device coupled with the diode laser

    Science.gov (United States)

    Bartels, Kenneth E.; Henry, George A.; Dickey, D. Thomas; Stair, Ernest L.; Powell, Ronald; Schafer, Steven A.; Nordquist, Robert E.; Frederickson, Christopher J.; Hayes, Donald J.; Wallace, David B.

    1998-07-01

    Use of holmium laser energy for vaporization/coagulation of the nucleus pulposus in canine intervertebral discs has been previously reported and is currently being applied clinically in veterinary medicine. The procedure was originally developed in the canine model and intended for potential human use. Since the pulsed (15 Hz) holmium laser energy exerts photomechanical and photothermal effects, the potential for extrusion of additional disc material to the detriment of the patient is possible using the procedure developed for the dog. To reduce this potential complication, use of diode laser (805 nm - CW mode) energy, coupled with indocyanine green (ICG) as a selective laser energy absorber, was formulated as a possible alternative. Delivery of the ICG and diode laser energy was through a MicroJet device that could dispense dye interactively between individual laser 'shots.' Results have shown that it is possible to selectively ablate nucleus pulposus in the canine model using the device described. Acute observations (gross and histopathologic) illustrate that accurate placement of the spinal needle before introduction of the MicroJet device is critically dependent on the expertise of the interventional radiologist. In addition, the success of the overall technique depends on consistent delivery of both ICG and diode laser energy. Minimizing tissue carbonization on the tip of the MicroJet device is also of crucial importance for effective application of the technique in clinical veterinary medicine.

  9. Penetration pattern of rhodamine dyes into enamel and dentin: confocal laser microscopy observation.

    Science.gov (United States)

    Kwon, S R; Wertz, P W; Li, Y; Chan, D C N

    2012-02-01

    Enamel and dentin are susceptible to extrinsic and intrinsic stains. The purposes of this study were to determine the penetration pattern of Rhodamine B and dextran-conjugated Rhodamine B into the enamel and dentin as observed by confocal laser microscopy and to relate it to the penetration pattern of hydrogen peroxide commonly used as an active ingredient in tooth-whitening agents and high-molecular-weight staining molecules. Eighteen recently extracted human maxillary anterior teeth were used. Teeth were cleaned and painted with nail varnish except for the crown area above the cemento-enamel junction (CEJ). The painted teeth were then immersed in Rhodamine B and dextran-conjugated Rhodamine B (70 000 MW) for 4, 7, 10 and 15 days. Teeth were sliced to 3 mm thickness in transverse plane and mounted on a glass slide just prior to observation with confocal laser microscopy. Rhodamine B and dextran-conjugated Rhodamine B readily penetrated into the enamel and dentin when exposed for 4 and 7 days, respectively. Rhodamine B penetrated along the interprismatic spaces of the enamel into the dentin. The penetration was accentuated in sections with existing crack lines in the enamel. Rhodamine B was readily absorbed into the dentinal tubules at the dentino-enamel junction and continued to penetrate through the dentin via the dentinal tubules into the pre-dentin. Within the limitations of this study, it is concluded that Rhodamine B and dextran-conjugated Rhodamine B when applied to the external surface of the tooth readily penetrate into the enamel and dentin via the interprismatic spaces in the enamel and dentinal tubules in the dentin, suggesting that stain molecules and bleaching agents possibly exhibit similar penetration pathways. © 2011 The Authors. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  10. Detection of gain enhancement in laser-induced fluorescence of rhodamine B lasing dye by silicon dioxide nanostructures-coated cavity

    Science.gov (United States)

    Al-Tameemi, Mohammed N. A.

    2018-03-01

    In this work, nanostructured silicon dioxide films are deposited by closed-field unbalanced direct-current (DC) reactive magnetron sputtering technique on two sides of quartz cells containing rhodamine B dye dissolved in ethanol with 10‒5 M concentration as a random gain medium. The preparation conditions are optimized to prepare highly pure SiO2 nanostructures with a minimum particle size of about 20 nm. The effect of SiO2 films as external cavity for the random gain medium is determined by the laser-induced fluorescence of this medium, and an increase of about 200% in intensity is observed after the deposition of nanostructured SiO2 thin films on two sides of the dye cell.

  11. Efficacy of pulsed dye laser treatment for common warts is not influenced by the causative HPV type: a prospective study.

    Science.gov (United States)

    Fichman, Yoseph; Levi, Assi; Hodak, Emmilia; Halachmi, Shlomit; Mazor, Sigal; Wolf, Dana; Caplan, Orit; Lapidoth, Moshe

    2018-05-01

    Verruca vulgaris (VV) is a prevalent skin condition caused by various subtypes of human papilloma virus (HPV). The most common causes of non-genital lesions are HPV types 2 and 4, and to a lesser extent types 1, 3, 26, 29, and 57. Although numerous therapeutic modalities exist, none is universally effective or without adverse events (AE). Pulsed dye laser (PDL) is a favorable option due to its observed efficacy and relatively low AE rate. However, it is not known which verrucae are most likely to respond to PDL, or whether the causative viral subtype influences this response. The objective of this prospective blinded study was to assess whether the HPV subtype was predictive of response to PDL. For that matter, 26 verrucae from 26 immunocompetent patients were biopsied prior to treatment by PDL. HPV coding sequences were isolated and genotyped using PCR analysis. Patients were treated by PDL (595 nm wavelength, 5 mm spot size, 1.5 ms pulse duration, 12 J/cm 2 fluence) once a month for up to 6 months, and clinical response was assessed. Binary logistic regression analysis and linear logistic regression analysis were used in order to evaluate statistical significance. Different types of HPV were identified in 22 of 26 tissue samples. Response to treatment did not correlate with HPV type, age, or gender. As no association between HPV type and response to PDL therapy could be established, it is therefore equally effective for all HPV types and remains a favorable treatment option for all VV.

  12. Synthesis, spectroscopic and TD-DFT quantum mechanical study of azo-azomethine dyes. A laser induced trans-cis-trans photoisomerization cycle.

    Science.gov (United States)

    Georgiev, Anton; Kostadinov, Anton; Ivanov, Deyan; Dimov, Deyan; Stoyanov, Simeon; Nedelchev, Lian; Nazarova, Dimana; Yancheva, Denitsa

    2018-03-05

    This paper describes the synthesis, spectroscopic characterization and quantum mechanical calculations of three azo-azomethine dyes. The dyes were synthesized via condensation reaction between 4-(dimethylamino)benzaldehyde and three different 4-aminobenzene azo dyes. Quantum chemical calculations on the optimized molecular geometry and electron densities of the trans (E) and cis (Z) isomers and their vibrational frequencies have been computed by using DFT/B3LYP density-functional theory with 6-311++G(d,p) basis set in vacuo. The thermodynamic parameters such as total electronic energy E (RB3LYP), enthalpy H 298 (sum of electronic and thermal enthalpies), free Gibbs energy G 298 (sum of electronic and thermal free Gibbs energies) and dipole moment μ were computed for trans (E) and cis (Z) isomers in order to estimate the ΔE trans→cis , Δμ trans→cis, ΔH trans→cis , ΔG trans→cis and ΔS trans→cis values. After molecular geometry optimization the electronic spectra have been obtained by TD-DFT calculations at same basis set and correlated with the spectra of vapour deposited nanosized films of the dyes. The NBO analysis was performed in order to understand the intramolecular charge transfer and energy of resonance stabilization. Solvatochromism was investigated by UV-VIS spectroscopy in five different organic solvents with increasing polarity. The dynamic photoisomerization experiments have been performed in DMF by pump lasers λ=355nm (mostly E→Z) and λ=491nm (mostly Z→E) in spectral region 300nm - 800nm at equal concentrations and times of illumination in order to investigate the photodynamical trans-cis-trans properties of the CHN and NN chromophore groups of the dyes. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. The UV and Laser Aging for PMMA/BDK/Azo-dye Polymer Blend Cured by UV Light Beams

    International Nuclear Information System (INIS)

    Ahmad, A A; Omari, A M

    2015-01-01

    A polymeric-based solution blend composed of Azo-dye methyl red (MR) doped with polymethelmethacrelate (PMMA) solution, in addition, to the BenzylDimethylKetal (BDK) photoinitiator was made with optimum molar ratios and deposited on glass substrate by spin coating technique. The samples were then exposed to UV light beams in order to assist the layers polymerization by the proper exposure process. The photo chemical reaction occurred during the UV light polymerization process induces photo refractive changes which were presented as a function of wavelength or photon energy. Two main strong absorption peaks were observed in the films at around 330 nm (3.75 eV) and 500 nm (2.48 eV) for different curing time periods. This phenomenon enhances the films usage for optical data storage media at these two wavelengths. Since the deposited films were then useful as based layers for Read/Write optical data storage media, they were then tested by UV or laser Read/Write beams independently. The optical properties of the films were investigated while exposed to each beam. Finally, their optical properties were investigated as a function of aging time in order to relate the temporary and/or permanent light-exposure effect on the films compared to their optical properties before the light exposure. The films show a low absorbance at 630 nm (1.97 eV) and high absorbance at 480 nm (2.58 eV). This fact makes it possible to record holographic gratings in the polymeric film upon light exposure. In all cases the optical properties were evaluated by using the very sensitive, non destructive surface testing spectroscopic ellipsometry technique. The films were characterized in the spectral range of 300 to 1000 nm using Lorentz oscillator model with one oscillator centred at 4.15 eV. This study has been supported by the SEM and EDAX results to investigate the effect of the UV and visible beams on their optical properties. The results of this research determined the proper conditions for

  14. Droplet size in a rectangular Venturi scrubber

    OpenAIRE

    Costa, M. A. M.; Henrique, P. R.; Gonçalves, J. A. S.; Coury, J.R.

    2004-01-01

    The Venturi scrubber is a device which uses liquid in the form of droplets to efficiently remove fine particulate matter from gaseous streams. Droplet size is of fundamental importance for the scrubber performance. In the present experimental study, a laser diffraction technique was used in order to measure droplet size in situ in a Venturi scrubber with a rectangular cross section. Droplet size distribution was measured as a function of gas velocity (58.3 to 74.9 m/s), liquid-to-gas ratio (0...

  15. Spectral dependence of some UV-B and UV-C responses of Tetrahymena pyriformis irradiated with dye laser generated UV

    International Nuclear Information System (INIS)

    Calkins, John; Colley, Ed; Wheeler, John; Kentucky Univ., Lexington

    1987-01-01

    We have generated UV-B and UV-C radiations using a flashlamp driven tunable dye laser combined with frequency doubling crystals. Using this novel UV source, we have investigated lethality and its modification by growth phase, photoreactivation and caffeine in Tetrahymena pyriformis at 254 nm and from 260-315 nm in 5 nm steps. From the observed responses we have constructed action spectra for lethality, with or without caffeine (a repair inhibitor) and under conditions of photoreactivation. We have also estimated quantum efficiencies for these responses. Our observations suggest that complex changes in response occur at several wavelengths over the UV-C and UV-B regions. (author)

  16. Intense pulsed light vs. long-pulsed dye laser treatment of telangiectasia after radiotherapy for breast cancer: a randomized split-lesion trial of two different treatments

    DEFF Research Database (Denmark)

    Nymann, P.; Hedelund, L.; Hædersdal, Merete

    2009-01-01

    Background Chronic radiodermatitis is a common sequela of treatment for breast cancer and potentially a psychologically distressing factor for the affected women. Objectives To evaluate the efficacy and adverse effects of treatments with a long-pulsed dye laser (LPDL) vs. intense pulsed light (IPL......); the interventions were randomly assigned to left/right or upper/lower halves. Primary end-points were reduction in telangiectasia, patient satisfaction and preferred treatment. Secondary end-points were pain and adverse effects. Efficacy was registered by blinded photographic evaluations 3 months after the final...

  17. Discharge of viscous UV-curable resin droplets by screen printing for UV nanoimprint lithography

    Science.gov (United States)

    Tanabe, Akira; Uehara, Takuya; Nagase, Kazuro; Ikedo, Hiroaki; Hiroshiba, Nobuya; Nakamura, Takahiro; Nakagawa, Masaru

    2016-06-01

    We demonstrated a coating method of screen printing for discharging droplets of a high-viscosity resin on a substrate for ultraviolet (UV) nanoimprint lithography (NIL). Compared with a spin-coated resin film on a silicon substrate, discharged resin droplets on a silicon substrate were effective in terms of the uniformity of residual layer thickness (RLT) in contact with a mold with various pattern densities. Fluorescence microscope observations with a fluorescent-dye-containing UV-curable resin enabled the evaluation of the shapes of resin droplets discharged on a substrate surface. Widely used screen mesh plates composed of a stainless mesh covered with a patterned emulsion film caused defects of undischarged parts, whereas defects-free resin droplets with a narrow size distribution were discharged by mesh-free plates prepared with laser ablation. The pitch-to-diameter ratio in the configuration of 10-µm-diameter holes needs to be larger than 2.5 times for printing a resin having a viscosity of 12,800 mPa s.

  18. A Search for Some Wide-Range Tunable Dye Laser Systems Working on the ’Exciplex’ Principle.

    Science.gov (United States)

    The ’ exciplex ’ mechanism of radiation emission from a dye affords one means of producing a broad fluorescent spectrum without adding to the...emissions from both the dye and the exciplex may appear, thereby permitting an even greater tuning range. Two mechanisms apply: the ’proton exciplex ...8217, which relates to changes in conventional acidity and basicity in the excited state; and the ’molecular exciplex ’, which relates to changes in

  19. Randomized, controlled trial split-faced study of 595-nm pulsed dye laser in the treatment of acne vulgaris and acne erythema in adolescents and early adulthood.

    Science.gov (United States)

    Lekwuttikarn, Ramrada; Tempark, Therdpong; Chatproedprai, Susheera; Wananukul, Siriwan

    2017-08-01

    The high prevalence of acne vulgaris in teenagers has increased comorbidities. Lasers offer alternative options for acne treatment because they have rapid action, low systemic adverse effects, and do not require everyday treatment. To study the efficacy and patients' satisfaction of 595-nm pulse dye laser (PDL) treatment of acne vulgaris and acne erythema in adolescents and early adulthood, we designed a blocked-randomized, split-faced 595-nm PDL (fluence 8 J/cm 3 pulse duration 10 ms, spot size 7 mm, 2 session every 2 weeks) study in patients with mild to moderate acne by comparing the laser-treated and non-treated side. The acne lesion counts, acne erythema grading, and acne severity grading were evaluated at baseline and 2, 4, and 8 weeks. Thirty patients were recruited. The results showed no statistically significant difference except the papule count at week 4 which was -1.828 on the treated side and 0.103 on the non-treated side of the face, P-value 0.0018. There was no statistically significant difference of acne severity grading and acne erythema grading between both sides of the face. The mean scores of patients' satisfaction on the laser-treated side were 75, 81, and 81%, respectively. The PDL treatment in this study reveals no significant improvement in acne therapy; however, the patients were satisfied with this laser treatment. © 2017 The International Society of Dermatology.

  20. Theoretical studies of solar-pumped lasers

    Science.gov (United States)

    Harries, W. L.

    1983-01-01

    Possible types of lasers were surveyed for solar power conversion. The types considered were (1) liquid dye lasers, (2) vapor dye lasers, and (3) nondissociative molecular lasers. These are discussed.

  1. Long-pulsed dye laser versus intense pulsed light for photodamaged skin: A randomized split-face trial with blinded response evaluation

    DEFF Research Database (Denmark)

    Jorgensen, G.F.; Hedelund, L.; Haedersdal, M.

    2008-01-01

    Objective: In a randomized controlled split-face trial to evaluate efficacy and adverse effects from rejuvenation with long-pulsed dye laser (LPDL) versus intense pulsed light (IPL). Materials and Methods: Twenty female volunteers with Fitzpatrick skin types I-III, classes I-II rhytids......, and symmetrical split-face photodamage were included in the study. Subjects received a series of three treatments at 3-week intervals with half-face LPDL (V-beam Perfecta, 595 nm, Candela Laser Corporation) and half-face IPL (Ellipse Flex, Danish Dermatologic Development); the interventions being randomly...... assigned to left and right sides. Primary end-points were telangiectasias, irregular pigmentation and preferred treatment. Secondary end-points were skin texture, rhytids, pain, and adverse effects. Efficacy was evaluated by patient self-assessments and by blinded clinical on-site and photographic...

  2. Determination of Metals Present in Textile Dyes Using Laser-Induced Breakdown Spectroscopy and Cross-Validation Using Inductively Coupled Plasma/Atomic Emission Spectroscopy

    Directory of Open Access Journals (Sweden)

    K. Rehan

    2017-01-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS was used for the quantitative analysis of elements present in textile dyes at ambient pressure via the fundamental mode (1064 nm of a Nd:YAG pulsed laser. Three samples were collected for this purpose. Spectra of textile dyes were acquired using an HR spectrometer (LIBS2000+, Ocean Optics, Inc. having an optical resolution of 0.06 nm in the spectral range of 200 to 720 nm. Toxic metals like Cr, Cu, Fe, Ni, and Zn along with other elements like Al, Mg, Ca, and Na were revealed to exist in the samples. The %-age concentrations of the detected elements were measured by means of standard calibration curve method, intensities of every emission from every species, and calibration-free (CF LIBS approach. Only Sample 3 was found to contain heavy metals like Cr, Cu, and Ni above the prescribed limit. The results using LIBS were found to be in good agreement when compared to outcomes of inductively coupled plasma/atomic emission spectroscopy (ICP/AES.

  3. Pulsed dye laser in the treatment of localized scleroderma and its effects on CD34+ and factor XIIIa+ cells: an immunohistochemical study.

    Science.gov (United States)

    Tawfik, Abeer Attia; Shokir, Hisham; Soliman, Mona; Salah, Lila; Fathy, Sahar

    2013-06-01

    Localized scleroderma (morphea) is characterized by hardening and thickening of the dermis due to excessive collagen deposition. A decreased number of CD34+ cells and an increased number of Factor XIIIa+ cells are seen in the affected skin. The flashlamp pulsed dye laser (FLPDL) has been used in the treatment of localized morphea with promising results. The purpose of this study was to evaluate the therapeutic effectiveness of the pulsed dye laser in localized scleroderma and to assess its effect on CD34+ cells, Factor XIIIa+ cells, and blood vessels. Thirty patients with plaque morphea were treated with a FLPDL (585 nm wavelength, 450 μs pulse duration). Fluence ranged from 7.5 to 8.5 J/cm(2). Sessions were performed biweekly for a maximum of 6 months. Clinical, histopathologic, and immunohistochemical assessments were performed. Patients showed varying degrees of improvement of indurated skin. There was no worsening or further improvement at the treated sites during the follow-up assessments at 3, 6, and 12 months. An increased number of CD34+ cells were found in both the upper and the lower dermis, and a decreased number of Factor XIIIa+ cells were found in the lower dermis. The FLPDL is effective in the treatment of morphea, as confirmed by the changes in the pathologic tissue and levels of CD34+ and Factor XIIIa+ cells.

  4. Mass spectrometry of acoustically levitated droplets.

    Science.gov (United States)

    Westphall, Michael S; Jorabchi, Kaveh; Smith, Lloyd M

    2008-08-01

    Containerless sample handling techniques such as acoustic levitation offer potential advantages for mass spectrometry, by eliminating surfaces where undesired adsorption/desorption processes can occur. In addition, they provide a unique opportunity to study fundamental aspects of the ionization process as well as phenomena occurring at the air-droplet interface. Realizing these advantages is contingent, however, upon being able to effectively interface levitated droplets with a mass spectrometer, a challenging task that is addressed in this report. We have employed a newly developed charge and matrix-assisted laser desorption/ionization (CALDI) technique to obtain mass spectra from a 5-microL acoustically levitated droplet containing peptides and an ionic matrix. A four-ring electrostatic lens is used in conjunction with a corona needle to produce bursts of corona ions and to direct those ions toward the droplet, resulting in droplet charging. Analyte ions are produced from the droplet by a 337-nm laser pulse and detected by an atmospheric sampling mass spectrometer. The ion generation and extraction cycle is repeated at 20 Hz, the maximum operating frequency of the laser employed. It is shown in delayed ion extraction experiments that both positive and negative ions are produced, behavior similar to that observed for atmospheric pressure matrix-assisted laser absorption/ionization. No ion signal is observed in the absence of droplet charging. It is likely, although not yet proven, that the role of the droplet charging is to increase the strength of the electric field at the surface of the droplet, reducing charge recombination after ion desorption.

  5. Dispersive liquid-phase microextraction with solidification of floating organic droplet coupled with high-performance liquid chromatography for the determination of Sudan dyes in foodstuffs and water samples.

    Science.gov (United States)

    Chen, Bo; Huang, Yuming

    2014-06-25

    Dispersive liquid-phase microextraction with solidification of floating organic drop (SFO-DLPME) is one of the most interesting sample preparation techniques developed in recent years. In this paper, a new, rapid, and efficient SFO-DLPME coupled with high-performance liquid chromatography (HPLC) was established for the extraction and sensitive detection of banned Sudan dyes, namely, Sudan I, Sudan II, Sudan III, and Sudan IV, in foodstuff and water samples. Various factors, such as the type and volume of extractants and dispersants, pH and volume of sample solution, extraction time and temperature, ion strength, and humic acid concentration, were investigated and optimized to achieve optimal extraction of Sudan dyes in one single step. After optimization of extraction conditions using 1-dodecanol as an extractant and ethanol as a dispersant, the developed procedure was applied for extraction of the target Sudan dyes from 2 g of food samples and 10 mL of the spiked water samples. Under the optimized conditions, all Sudan dyes could be easily extracted by the proposed SFO-DLPME method. Limits of detection of the four Sudan dyes obtained were 0.10-0.20 ng g(-1) and 0.03 μg L(-1) when 2 g of foodstuff samples and 10 mL of water samples were adopted, respectively. The inter- and intraday reproducibilities were below 4.8% for analysis of Sudan dyes in foodstuffs. The method was satisfactorily used for the detection of Sudan dyes, and the recoveries of the target for the spiked foodstuff and water samples ranged from 92.6 to 106.6% and from 91.1 to 108.6%, respectively. These results indicated that the proposed method is simple, rapid, sensitive, and suitable for the pre-concentration and detection of the target dyes in foodstuff samples.

  6. Droplet size in a rectangular Venturi scrubber

    Directory of Open Access Journals (Sweden)

    M. A. M. Costa

    2004-06-01

    Full Text Available The Venturi scrubber is a device which uses liquid in the form of droplets to efficiently remove fine particulate matter from gaseous streams. Droplet size is of fundamental importance for the scrubber performance. In the present experimental study, a laser diffraction technique was used in order to measure droplet size in situ in a Venturi scrubber with a rectangular cross section. Droplet size distribution was measured as a function of gas velocity (58.3 to 74.9 m/s, liquid-to-gas ratio (0.07 to 0.27 l/m³, and distance from liquid injection point (64 to 173 mm. It was found that all these variables significantly affect droplet size. The results were compared with the predictions from correlations found in the literature.

  7. Droplet sizes, dynamics and deposition in vertical annular flow

    International Nuclear Information System (INIS)

    Lopes, J.C.B.; Dukler, A.E.

    1985-10-01

    The role of droplets in vertical upwards annular flow is investigated, focusing on the droplet size distributions, dynamics, and deposition phenomena. An experimental program was performed based on a new laser optical technique developed in these laboratories and implemented here for annular flow. This permitted the simultaneous measurement of droplet size, axial and radial velocity. The dependence of droplet size distributions on flow conditions is analyzed. The Upper-Log Normal function proves to be a good model for the size distribution. The mechanism controlling the maximum stable drop size was found to result from the interaction of the pressure fluctuations of the turbulent flow of the gas core with the droplet. The average axial droplet velocity showed a weak dependence on gas rates. This can be explained once the droplet size distribution and droplet size-velocity relationship are analyzed simultaneously. The surprising result from the droplet conditional analysis is that larger droplet travel faster than smaller ones. This dependence cannot be explained if the drag curves used do not take into account the high levels of turbulence present in the gas core in annular flow. If these are considered, then interesting new situations of multiplicity and stability of droplet terminal velocities are encountered. Also, the observed size-velocity relationship can be explained. A droplet deposition is formulated based on the particle inertia control. This permitted the calculation of rates of drop deposition directly from the droplet size and velocities data

  8. Vaporization of irradiated droplets

    International Nuclear Information System (INIS)

    Armstrong, R.L.; O'Rourke, P.J.; Zardecki, A.

    1986-01-01

    The vaporization of a spherically symmetric liquid droplet subject to a high-intensity laser flux is investigated on the basis of a hydrodynamic description of the system composed of the vapor and ambient gas. In the limit of the convective vaporization, the boundary conditions at the fluid--gas interface are formulated by using the notion of a Knudsen layer in which translational equilibrium is established. This leads to approximate jump conditions at the interface. For homogeneous energy deposition, the hydrodynamic equations are solved numerically with the aid of the CON1D computer code (''CON1D: A computer program for calculating spherically symmetric droplet combustion,'' Los Alamos National Laboratory Report No. LA-10269-MS, December, 1984), based on the implict continuous--fluid Eulerian (ICE) [J. Comput. Phys. 8, 197 (1971)] and arbitrary Lagrangian--Eulerian (ALE) [J. Comput. Phys. 14, 1227 (1974)] numerical mehtods. The solutions exhibit the existence of two shock waves propagating in opposite directions with respect to the contact discontinuity surface that separates the ambient gas and vapor

  9. Laser induced photocurrent and photovoltage transient measurements of dye-sensitized solar cells based on TiO_2 nanosheets and TiO_2 nanoparticles

    International Nuclear Information System (INIS)

    Ghaithan, Hamid M.; Qaid, Saif M.H.; Hezam, Mahmoud; Labis, Joselito P.; Alduraibi, Mohammad; Bedja, Idriss M.; Aldwayyan, Abdullah S.

    2016-01-01

    Dye-sensitized solar cells (DSSCs) based on TiO_2 nanoparticles and TiO_2 nanosheets with exposed {001} facets are investigated using laser-induced photovoltage and photocurrent transient decay (LIPVCD) measurements. We adopted a simplified version of LIPVCD technique, in which a single illumination light source and a laboratory oscilloscope could be conveniently used for the measurements. Although the {001} surface of TiO_2 nanosheets allowed a noticeably slower recombination with the electrolyte, this was counterpoised by a slower electron transport probably due to its planar morphology, resulting in a shorter diffusion length in TiO_2 nanosheets. The nanosheet morphology also resulted in less surface area and therefore reduced short circuit current density in the fabricated devices. Our work highlights the fact that the morphological parameters of TiO_2 nanosheets finally resulting after electrode film deposition is of no less importance than the reported efficient dye adsorption and slow electron recombination at the surface of individual nanosheets.

  10. Epidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study.

    Science.gov (United States)

    Tunnell, J W; Nelson, J S; Torres, J H; Anvari, B

    2000-01-01

    Higher laser fluences than currently used in therapy (5-10 J/cm(2)) are expected to result in more effective treatment of port wine stain (PWS) birthmarks. However, higher incident fluences increase the risk of epidermal damage caused by absorption of light by melanin. Cryogen spray cooling offers an effective method to reduce epidermal injury during laser irradiation. The objective of this study was to determine whether high laser incident fluences (15-30 J/cm(2)) could be used while still protecting the epidermis in ex vivo human skin samples. Non-PWS skin from a human cadaver was irradiated with a Candela ScleroPlus Laser (lambda = 585 nm; pulse duration = 1.5 msec) by using various incident fluences (8-30 J/cm(2)) without and with cryogen spray cooling (refrigerant R-134a; spurt durations: 40-250 msec). Assessment of epidermal damage was based on histologic analysis. Relatively short spurt durations (40-100 msec) protected the epidermis for laser incident fluences comparable to current therapeutic levels (8-10 J/cm(2)). However, longer spurt durations (100-250 msec) increased the fluence threshold for epidermal damage by a factor of three (up to 30 J/cm(2)) in these ex vivo samples. Results of this ex vivo study show that epidermal protection from high laser incident fluences can be achieved by increasing the cryogen spurt duration immediately before pulsed laser exposure. Copyright 2000 Wiley-Liss, Inc.

  11. Treatment of burn scars in Fitzpatrick phototype III patients with a combination of pulsed dye laser and non-ablative fractional resurfacing 1550 nm erbium:glass/1927 nm thulium laser devices.

    Science.gov (United States)

    Tao, Joy; Champlain, Amanda; Weddington, Charles; Moy, Lauren; Tung, Rebecca

    2018-01-01

    Burn scars cause cosmetic disfigurement and psychosocial distress. We present two Fitzpatrick phototype (FP) III patients with burn scars successfully treated with combination pulsed dye laser (PDL) and non-ablative fractional lasers (NAFL). A 30-year-old, FP III woman with a history of a second-degree burn injury to the bilateral arms and legs affecting 30% body surface area (BSA) presented for cosmetic treatment. The patient received three treatments with 595 nm PDL (7 mm, 8 J, 6 ms), six with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and five with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). Treated burn scars improved significantly in thickness, texture and colour. A 33-year-old, FP III man with a history of a second-degree burn injury of the left neck and arm affecting 7% BSA presented for cosmetic treatment. The patient received two treatments with 595 nm PDL (5 mm, 7.5 J, 6 ms), four with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and two with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). The burn scars became thinner, smoother and more normal in pigmentation and appearance. Our patients' burn scars were treated with a combination of PDL and NAFL (two wavelengths). The PDL targets scar hypervascularity, the 1550 nm erbium:glass stimulates collagen remodelling and the 1927 nm thulium targets epidermal processes, particularly hyperpigmentation. This combination addresses scar thickness, texture and colour with a low side effect profile and is particularly advantageous in patients at higher risk of post-procedure hyperpigmentation. Our cases suggest the combination of 595nm PDL plus NAFL 1550 nm erbium:glass/1927 nm thulium device is effective and well-tolerated for burn scar treatment in skin of colour.

  12. Evaluation of droplet size distributions using univariate and multivariate approaches

    DEFF Research Database (Denmark)

    Gauno, M.H.; Larsen, C.C.; Vilhelmsen, T.

    2013-01-01

    of the distribution. The current study was aiming to compare univariate and multivariate approach in evaluating droplet size distributions. As a model system, the atomization of a coating solution from a two-fluid nozzle was investigated. The effect of three process parameters (concentration of ethyl cellulose...... in ethanol, atomizing air pressure, and flow rate of coating solution) on the droplet size and droplet size distribution using a full mixed factorial design was used. The droplet size produced by a two-fluid nozzle was measured by laser diffraction and reported as volume based size distribution....... Investigation of loading and score plots from principal component analysis (PCA) revealed additional information on the droplet size distributions and it was possible to identify univariate statistics (volume median droplet size), which were similar, however, originating from varying droplet size distributions...

  13. Laser welding of nanoparticulate TiO2 and transparent conducting oxide electrodes for highly efficient dye-sensitized solar cell

    International Nuclear Information System (INIS)

    Kim, Jinsoo; Kim, Jonghyun; Lee, Myeongkyu

    2010-01-01

    Poor interfacial contact is often encountered in nanoparticulate film-based devices. The dye-sensitized solar cell (DSSC) is a representative case in which a nanoporous TiO 2 electrode needs to be prepared on the transparent conducting oxide (TCO)-coated glass substrate. In this study, we demonstrate that the inter-electrode contact resistance accounts for a considerable portion of the total resistance of a DSSC and its efficiency can be greatly enhanced by welding the interface with a laser. TiO 2 films formed on the TCO-coated glass substrate were irradiated with a pulsed ultraviolet laser beam at 355 nm; this transmits through the TCO and glass but is strongly absorbed by TiO 2 . Electron microscopy analysis and impedance measurements showed that a thin continuous TiO 2 layer is formed at the interface as a result of the local melting of TiO 2 nanoparticles and this layer completely bridges the gap between the two electrodes, improving the current flow with a reduced contact resistance. We were able to improve the efficiency by 35-65% with this process. DSSCs fabricated using a homemade TiO 2 paste revealed an efficiency improvement from η = 3.3% to 5.4%, and an increase from 8.2% to 11.2% was achieved with the TiO 2 electrodes made from a commercial paste.

  14. Double Pass 595 nm Pulsed Dye Laser Does Not Enhance the Efficacy of Port Wine Stains Compared with Single Pass: A Randomized Comparison with Histological Examination.

    Science.gov (United States)

    Yu, Wenxin; Zhu, Jiafang; Wang, Lizhen; Qiu, Yajing; Chen, Yijie; Yang, Xi; Chang, Lei; Ma, Gang; Lin, Xiaoxi

    2018-03-27

    To compare the efficacy and safety of double-pass pulsed dye laser (DWL) and single-pass PDL (SWL) in treating virgin port wine stain (PWS). The increase in the extent of vascular damage attributed to the use of double-pass techniques for PWS remains inconclusive. A prospective, side-by-side comparison with a histological study for virgin PWS is still lacking. Twenty-one patients (11 flat PWS, 10 hypertrophic PWS) with untreated PWS underwent 3 treatments at 2-month intervals. Each PWS was divided into three treatment sites: SWL, DWL, and untreated control. Chromametric and visual evaluation of the efficacy and evaluation of side effects were conducted 3 months after final treatment. Biopsies were taken at the treated sites immediately posttreatment. Chromametric and visual evaluation suggested that DWL sites showed no significant improvement compared with SWL (p > 0.05) in treating PWS. The mean depth of photothermal damage to the vessels was limited to a maximum of 0.36-0.41 mm in both SWL and DWL sides. Permanent side effects were not observed in any patients. Double-pass PDL does not enhance PWS clearance. To improve the clearance of PWS lesions, either the depth of laser penetration should be increased or greater photothermal damage to vessels should be generated.

  15. Laser welding of nanoparticulate TiO{sub 2} and transparent conducting oxide electrodes for highly efficient dye-sensitized solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinsoo; Kim, Jonghyun; Lee, Myeongkyu, E-mail: myeong@yonsei.ac.kr [Department of Materials Science and Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of)

    2010-08-27

    Poor interfacial contact is often encountered in nanoparticulate film-based devices. The dye-sensitized solar cell (DSSC) is a representative case in which a nanoporous TiO{sub 2} electrode needs to be prepared on the transparent conducting oxide (TCO)-coated glass substrate. In this study, we demonstrate that the inter-electrode contact resistance accounts for a considerable portion of the total resistance of a DSSC and its efficiency can be greatly enhanced by welding the interface with a laser. TiO{sub 2} films formed on the TCO-coated glass substrate were irradiated with a pulsed ultraviolet laser beam at 355 nm; this transmits through the TCO and glass but is strongly absorbed by TiO{sub 2}. Electron microscopy analysis and impedance measurements showed that a thin continuous TiO{sub 2} layer is formed at the interface as a result of the local melting of TiO{sub 2} nanoparticles and this layer completely bridges the gap between the two electrodes, improving the current flow with a reduced contact resistance. We were able to improve the efficiency by 35-65% with this process. DSSCs fabricated using a homemade TiO{sub 2} paste revealed an efficiency improvement from {eta} = 3.3% to 5.4%, and an increase from 8.2% to 11.2% was achieved with the TiO{sub 2} electrodes made from a commercial paste.

  16. Long-term psychological impact and perceived efficacy of pulsed-dye laser therapy for patients with port-wine stains.

    Science.gov (United States)

    Hansen, Kristen; Kreiter, Clarence D; Rosenbaum, Marcy; Whitaker, Duane C; Arpey, Christopher J

    2003-01-01

    The rationale for treatment of patients with port-wine stain (PWS) birthmarks has focused on the belief that eventual soft-tissue hypertrophy and negative psychological effects might be diminished or avoided. Pulsed-dye laser (PDL) therapy has become widely accepted as the treatment of choice for PWS, and a variety of studies have been conducted that evaluate its short-term efficacy. Long-term data regarding outcome and patient satisfaction are lacking. Our objective was to evaluate the long-term efficacy of pulsed-dye laser therapy from the patient's perspective. A survey was mailed to all patients or parents of minor patients whose last known laser treatment was performed between January 1, 1989, and January 1, 1996. Patients were asked to quantify changes in their PWS as well as their psychological well-being. A formal qualitative analysis was performed on their written comments as well. A total of 164 surveys were mailed to the most recent address available by the patient record. Fifty-two surveys were returned as undeliverable, and 55 evaluable surveys were returned, yielding a 49% overall return rate for patients who could be located. The mean age of respondents was 28.8 years, 96% of whom were white and 62% female. The mean number of years since last treatment was 7.04. The vast majority of patients noted little or no change in texture, height, or dimension of their PWS, whereas 62% noted color improvement. A majority or patients (60%) worried less about their appearance after treatment, whereas a similar number (61%) believed their ability to make friends or meet others was unaffected by treatment. Only 19% thought others looked at or treated them differently because of their PWS. Overall, 48% of patients indicated satisfaction with treatment, 24% dissatisfaction, and 28% neutral. On a 10-point scale indicating their likelihood of recommending treatment to someone similarly affected, the mean score was 7.42. Men were significantly and consistently less

  17. Computer-aided design and modeling of nickel dithiolene near-infrared dyes. 1998 summer research program for high school juniors at the University of Rochester's Laboratory for Laser Energetics. Student research reports

    International Nuclear Information System (INIS)

    Corsello, S.

    1999-03-01

    Recent advances in computational chemistry have made it feasible to design many types of molecules and predict their properties theoretically. The author applied these techniques to the design of organometallic transition-metal dyes absorbing in the near-infrared region of the spectrum which possess the combination of a large molar extinction coefficient, good chemical and thermal stability, and a high solubility in liquid crystal (LC) hosts. These properties are required for the dye to function as a near-infrared (IR) attenuator in a liquid crystal point diffraction interferometer (LCPDI) device that will be used as a beam diagnostic on the 60-beam OMEGA solid-state Nd:glass laser system at the University of Rochester's Laboratory for Laser Energetics. Using commercially available software, both the absorption spectra and solubility characteristics of bis[1,2-di-(p-n alkoxyphenyl)ethane-1,2-dithione] nickel dye complexes were modeled in an isotropic host (cyclohexane) and, in most cases, excellent agreement was found with experimental data. Two additional compounds utilizing the same nickel dithiolene core but with alkylthio and phenylalkylthio terminal groups have been designed and show excellent potential to produce dramatic improvements in both solubility and optical density (absorbance) in liquid crystalline hosts. Based upon my work, a new dye not previously reported, 2(C 4 S)2(C 4 SPh)DTNi, has been proposed to satisfy the LCPDI device requirements. The nickel dithiolene dyes may also find important applications in other technology areas such as near-IR photography and laser-based near-IR communications

  18. Laser resonance ionization scheme development for tellurium and germanium at the dual Ti:Sa–Dye ISOLDE RILIS

    Energy Technology Data Exchange (ETDEWEB)

    Day Goodacre, T., E-mail: thomas.day.goodacre@cern.ch [CERN, CH-1211 Geneva 23 (Switzerland); School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Fedorov, D. [Petersburg Nuclear Physics Institute, 188350 Gatchina (Russian Federation); Fedosseev, V.N.; Forster, L.; Marsh, B.A. [CERN, CH-1211 Geneva 23 (Switzerland); Rossel, R.E. [CERN, CH-1211 Geneva 23 (Switzerland); Institut für Physik, Johannes Gutenberg Universität, D-55099 Mainz (Germany); Faculty of Design, Computer Science and Media, Hochschule RheinMain, Wiesbaden (Germany); Rothe, S.; Veinhard, M. [CERN, CH-1211 Geneva 23 (Switzerland)

    2016-09-11

    The resonance ionization laser ion source (RILIS) is the principal ion source of the ISOLDE radioactive beam facility based at CERN. Using the method of in-source laser resonance ionization spectroscopy, a transition to a new autoionizing state of tellurium was discovered and applied as part of a three-step, three-resonance, photo-ionization scheme. In a second study, a three-step, two-resonance, photo-ionization scheme for germanium was developed and the ionization efficiency was measured at ISOLDE. This work increases the range of ISOLDE RILIS ionized beams to 31 elements. Details of the spectroscopy studies are described and the new ionization schemes are summarized.

  19. Laser resonance ionization scheme development for tellurium and germanium at the dual Ti:Sa–Dye ISOLDE RILIS

    CERN Document Server

    Day Goodacre, T.; Fedosseev, V.N.; Forster, L.; Marsh, B.A.; Rossel, R.E.; Rothe, S.; Veinhard, M.

    2016-01-01

    The resonance ionization laser ion source (RILIS) is the principal ion source of the ISOLDE radioactive beam facility based at CERN. Using the method of in-source laser resonance ionization spectroscopy, a transition to a new autoionizing state of tellurium was discovered and applied as part of a three-step, three-resonance, photo-ionization scheme. In a second study, a three-step, two-resonance, photo-ionization scheme for germanium was developed and the ionization efficiency was measured at ISOLDE. This work increases the range of ISOLDE RILIS ionized beams to 31 elements. Details of the spectroscopy studies are described and the new ionization schemes are summarized.

  20. Ratiometric, single-dye, pH-sensitive inhibited laser-induced fluorescence for the characterization of mixing and mass transfer

    Science.gov (United States)

    Lacassagne, Tom; Simoëns, Serge; El Hajem, Mahmoud; Champagne, Jean-Yves

    2018-01-01

    Inhibited planar laser-induced fluorescence (I-PLIF) techniques are widely used for heat and mass transfer studies in fluid mechanics. They allow the visualization of instantaneous two-dimensional field of a passive or reactive scalar, providing that this scalar acts as an inhibitor to the fluorescence of a specific molecule, and that this molecule is homogeneously mixed in the fluid at a known concentration. Local scalar values are deduced from fluorescence recordings thanks to preliminary calibration procedure. When confronted with non-optically thin systems, however, the knowledge of the excitation intensity distribution in the region of interest is also required, and this information is most of the time hard to obtain. To overcome that problem, two-color ratiometric PLIF techniques ( {I}^ {r}-PLIF) have been developed. In these methods, the ratio of two different fluorescence wavelengths triggered by the same excitation is used as an indicator of the scalar value. Such techniques have been used for temperature measurements in several studies but never, to the author's knowledge, for pH tracking and acid-base mixing, despite the frequent use of the one-color version in mass transfer studies. In the present work, a ratiometric pH-sensitive-inhibited PLIF technique ( {I}_ {pH}^ {r}-PLIF) using fluorescein sodium as a single dye and applicable to complex geometries and flows is developed. Theoretical considerations show that the ratio of the two-color fluorescence intensities should only depend on the dye's spectral quantum yield, itself pH-dependent. A detailed spectrofluorimetric study of fluorescein reveals that this ratio strictly increases with the pH for two well-chosen spectral bands (fluorescence colors). A similar trend is found when using sCmos cameras equipped with optical filters to record fluorescence signals. The method is then experimented on a test flow, a turbulent acidic jet injected in an initially pH-neutral volume of fluid. The results obtained

  1. Sampling system for pulsed signals. Study of the radioactive lifetimes of excited 32P1/2 and 32P3/2 states of Na, excited by a tunable dye laser

    International Nuclear Information System (INIS)

    Thomas, P.; Campos, J.

    1979-01-01

    A system for sampling and averaging repetitive signals in the order of nanoseconds is discussed. The system uses as storage memory a multichannel analyzer operating in multi scaling mode. This instrument is employed for the measurement of atomic level lifetimes using a dye laser to excite the atoms and is applied to the study of lifetimes of the 3 2 P1/2 and 3 2 P3/2 states of sodium. (Author) 32 refs

  2. Droplet phase characteristics in liquid-dominated steam--water nozzle flow

    International Nuclear Information System (INIS)

    Alger, T.W.

    1978-01-01

    An experimental study was undertaken to determine the droplet size distribution, the droplet spatial distribution and the mean droplet velocity in low-quality, steam-water flow from a rectangular cross-section, converging-diverging nozzle. A unique forward light scattering technique was developed for droplet size distribution measurements. Droplet spatial variations were investigated using light transmission measurements, and droplet velocities were measured with a laser-Doppler velocimeter (LDV) system incorporating a confocal Fabry-Perot interferometer. Nozzle throat radius of curvature and height were varied to investigte their effects on droplet size. Droplet size distribution measurements yielded a nominal Sauter mean droplet diameter of 1.7 μm and a nominal mass-mean droplet diameter of 2.4 μm. Neither the throat radius of curvature nor the throat height were found to have a significant effect upon the nozzle exit droplet size. The light transmission and LDV measurement results confirmed both the droplet size measurements and demonstrated high spatial uniformity of the droplet phase within the nozzle jet flow. One-dimensional numerical calculations indicated that both the dynamic breakup (thermal equilibrium based on a critical Weber number of 6.0) and the boiling breakup (thermal nonequilibrium based on average droplet temperature) models predicted droplet diameters on the order of 7.5 μm, which are approximately equal to the maximum stable droplet diameters within the nozzle jet flow

  3. New technique for laryngotracheal mucosa transplantation. 'Stamp' welding using indocyanine green dye and albumin interaction with diode laser.

    Science.gov (United States)

    Wang, Z; Pankratov, M M; Gleich, L L; Rebeiz, E E; Shapshay, S M

    1995-07-01

    To investigate (1) the possibility of survival of free mucosa "stamp" grafts fixed in the airway with a new technique using indocyanine green-dyed albumin solder activated with a diode laser and (2) the degree of improvement of wound healing in the airway by applying modified microskin transplantation techniques from burn surgery to cover a relatively large wound with a few small pieces of mucosa anchored in place with the previously mentioned technique. Three (one control and two experimental) rectangular (10 x 8 mm) wounds in tracheal mucosa were produced in four experimental animals (dogs) using a carbon dioxide laser. The control wound was left uncovered. In the first experimental wound, a mucosal flap was raised and then fixed in place by a trapdoor flap method. In the second experimental wound, two small (each 2 x 3 mm) autogenous mucosa grafts were anchored onto the surface with indocyanine green-dyed albumin activated with an 810-nm diode laser. Histomorphologically, the postoperative results from three wounds were compared. The experimental wounds were completely covered by regenerated squamous cells in 1 week and by ciliated epithelium in 2 weeks after the operation despite the discrepancy in size of the graft to wound area (1:6.7) covered with the stamp mucosa. No thermal damage from the diode laser was noted in the second experimental wounds. In the control wounds, no coverage was observed at 1 week, and only squamous cells were noted 2 weeks postoperatively. All the wounds had normal ciliated epithelium coverage at 4 weeks. Transplanted stamp grafts provided similar or better healing than trapdoor flap transplants. This new technique made endoscopic mucosal grafting possible and offers a potential breakthrough in the management of laryngotracheal stenosis.

  4. EMLA cream does not influence efficacy and pain reduction during pulsed-dye laser treatment of port-wine stain: a prospective side-by-side comparison.

    Science.gov (United States)

    Yu, Wenxin; Wang, Tianyou; Zhu, Jiafang; Qiu, Yajing; Chen, Hui; Jin, Yunbo; Yang, Xi; Hu, Xiaojie; Chang, Lei; Chen, Yijie; Ma, Gang; Lin, Xiaoxi

    2018-04-01

    EMLA cream was developed to reduce pain during pulsed-dye laser (PDL) treatment; however, no standard assessment for the therapeutic outcomes of PDL with EMLA creams thus far available. This comparative, prospective clinical trial evaluates laser efficacy and pain reduction during PDL treatment with EMLA cream for local topical anesthesia. Nineteen patients with untreated port-wine stain (PWS) were treated using PDL and examined in this study. Treatment specifications included Vbeam® PDL (Candela Corp.), 595-nm wavelength, 9 J/cm 2 radiant exposure, 0.45 ms pulse duration, 10 mm spot size, and cryogen spray cooling (40 ms cooling plus a 20 ms delay). A topical anesthetic (EMLA cream: 2.5% lidocaine and 2.5% prilocaine) and a placebo were applied to two respective testing areas on all patients prior to treatment. The visual analog scale (VAS) was used for pain assessment. Clinical therapeutic outcomes were evaluated by visual evaluation and with the use of a chromameter 2 months after 3PDL treatments. The average VAS scores were 3.15 ± 0.95 and 8 ± 0.57 for the EMLA cream site and the placebo site, respectively, at a significance level p < 0.001. The EMLA cream site and the placebo site had clearance or fading rates of 45.08 and 44.12%, respectively (p < 0.05). No serious side effects were reported. Patients reported a consistent decrease in pain during PDL treatment when the topical anesthetic EMLA cream was administered. Treatment of PWS by PDL with EMLA cream does not lead to a decrease in efficacy or an increase in side effects; instead, it significantly reduces pain during treatment. EMLA cream is a safe and effective local topical anesthetic for PWS treatment by PDL.

  5. Efficacy of treating children with anterior commissure and true vocal fold respiratory papilloma with the 585-nm pulsed-dye laser.

    Science.gov (United States)

    Hartnick, Christopher J; Boseley, Mark E; Franco, Ramon A; Cunningham, Michael J; Pransky, Seth

    2007-02-01

    To report preliminary results regarding the safety and efficacy of the 585-nm pulsed-dye laser (PDL) for the treatment of juvenile-onset recurrent respiratory papillomatosis (JORRP) in the pediatric population. Prospective longitudinal cohort study. Two pediatric otolaryngology referral centers. Twenty-three pediatric patients ranging in age from 6 months to 17 years. The 585-nm PDL was used for at least 1 treatment on each of these patients to treat JORRP of the true vocal folds or anterior commissure. Complications from the use of the 585-nm PDL in the treatment of JORRP. There was no evidence of anterior commissure webbing or true vocal fold scarring in this group of 23 patients followed up for 3 months to 1 year. The 585-nm PDL seems to be a safe instrument for treatment of JORRP. There is the potential that improved voice outcomes may be apparent when compared with traditional therapies because the vocal fold epithelium seems to be unharmed when treated with this method. Furthermore, the lack of epithelial damage incurred by the 585-nm PDL should enable more aggressive surgical excision of anterior commissure disease. Further prospective longitudinal studies examining voice outcomes are needed.

  6. Theoretical and experimental study of the relaxation of excited states of the DCM laser dye. Intra-molecular electron transfer and photo-isomerization. Solvent effects

    International Nuclear Information System (INIS)

    Marguet, Sylvie

    1992-01-01

    This research thesis reports the study of a styrenic laser dye, the 4-(dicyanomethylene)-2-methyl-6-[p-(dimethylamino) styryl]-4H-pyrane or DCM for the characterization of the first electronic states and of the influence of the solvent on efficiencies of different relaxation processes of the first excited state S1 of the DCM. Due to the presence of a combination of a donor group and acceptor group, this compound has interesting properties of intra-molecular charge transfer and of photo-isomerization which highly depend on solvent polarity. Two approaches have been adopted to study these complementary processes: an experimental approach (determination of rate constants of the different deactivation ways of the S1 state by measuring fluorescence quantum efficiencies, photo-isomerization quantum efficiencies, and fluorescence lifetimes of DCM in about twenty solvent of increasing polarity), and a computational approach (a CS-INDO-MRI type quantum chemistry calculation to obtain potential energy curves, charge distributions, and dipolar moments of DCM first electronic states) [fr

  7. Can long-term alopecia occur after appropriate pulsed-dye laser therapy in hair-bearing sites? Pediatric dermatologists weigh in.

    Science.gov (United States)

    Feldstein, Stephanie; Totri, Christine R; Friedlander, Sheila F

    2015-03-01

    The risk of long-term alopecia after pulsed-dye laser (PDL) therapy is unknown. To identify how many practitioners treat hair-bearing sites with PDL and how commonly long-term alopecia occurs, the authors queried pediatric dermatologists about their experiences using this modality. A survey was designed to evaluate the frequency of and factors contributing to long-term alopecia after PDL treatment of port-wine stains (PWS). "Long-term" was defined as no sign of hair regrowth after several years of nontreatment. The survey was administered to attendees at the 2014 Society for Pediatric Dermatology biannual meeting. Sixty-four pediatric dermatologists completed the survey, 50 of whom had experience using PDL. Of these physicians, 86% have used PDL to treat PWS of the eyebrow and 80% have treated PWS of the scalp. Over one-quarter of respondents (25.5%) using PDL on hair-bearing areas had at least 1 of their patients develop long-term alopecia after PDL treatment. The incidence of long-term alopecia after PDL treatment in the surveyed population was 1.5% to 2.6%. The occurrence of long-term alopecia at hair-bearing sites after treatment with PDL may be greater than previously thought. Because the majority of physicians using PDL treat hair-bearing areas, prospective studies are needed to more accurately determine the risk of long-term alopecia and the factors that contribute to it.

  8. Fluorescence detection system for microfluidic droplets

    Science.gov (United States)

    Chen, Binyu; Han, Xiaoming; Su, Zhen; Liu, Quanjun

    2018-05-01

    In microfluidic detection technology, because of the universality of optical methods in laboratory, optical detection is an attractive solution for microfluidic chip laboratory equipment. In addition, the equipment with high stability and low cost can be realized by integrating appropriate optical detection technology on the chip. This paper reports a detection system for microfluidic droplets. Photomultiplier tubes (PMT) is used as a detection device to improve the sensitivity of detection. This system improves the signal to noise ratio by software filtering and spatial filter. The fluorescence intensity is proportional to the concentration of the fluorescence and intensity of the laser. The fluorescence micro droplets of different concentrations can be distinguished by this system.

  9. Three-axis acoustic device for levitation of droplets in an open gas stream and its application to examine sulfur dioxide absorption by water droplets.

    Science.gov (United States)

    Stephens, Terrance L; Budwig, Ralph S

    2007-01-01

    Two acoustic devices to stabilize a droplet in an open gas stream (single-axis and three-axis levitators) have been designed and tested. The gas stream was provided by a jet apparatus with a 64 mm exit diameter and a uniform velocity profile. The acoustic source used was a Langevin vibrator with a concave reflector. The single-axis levitator relied primarily on the radial force from the acoustic field and was shown to be limited because of significant droplet wandering. The three-axis levitator relied on a combination of the axial and radial forces. The three-axis levitator was applied to examine droplet deformation and circulation and to investigate the uptake of SO(2) from the gas stream to the droplet. Droplets ranging in diameters from 2 to 5 mm were levitated in gas streams with velocities up to 9 ms. Droplet wandering was on the order of a half droplet diameter for a 3 mm diameter droplet. Droplet circulation ranged from the predicted Hadamard-Rybczynski pattern to a rotating droplet pattern. Droplet pH over a central volume of the droplet was measured by planar laser induced fluorescence. The results for the decay of droplet pH versus time are in general agreement with published theory and experiments.

  10. Droplet collisions in turbulence

    NARCIS (Netherlands)

    Oldenziel, G.

    2014-01-01

    Liquid droplets occur in many natural phenomena and play an important role in a large number of industrial applications. One of the distinct properties of droplets as opposed to solid particles is their ability to merge, or coalesce upon collision. Coalescence of liquid drops is of importance in for

  11. Butschli Dynamic Droplet System

    DEFF Research Database (Denmark)

    Armstrong, R.; Hanczyc, M.

    2013-01-01

    Dynamical oil-water systems such as droplets display lifelike properties and may lend themselves to chemical programming to perform useful work, specifically with respect to the built environment. We present Butschli water-in-oil droplets as a model for further investigation into the development...... reconstructed the Butschli system and observed its life span under a light microscope, observing chemical patterns and droplet behaviors in nearly three hundred replicate experiments. Self-organizing patterns were observed, and during this dynamic, embodied phase the droplets provided a means of introducing...... temporal and spatial order in the system with the potential for chemical programmability. The authors propose that the discrete formation of dynamic droplets, characterized by their lifelike behavior patterns, during a variable window of time (from 30 s to 30 min after the addition of alkaline water...

  12. Treatment of port wine stains with pulsed dye laser: a retrospective study of 848 cases in Shandong Province, People’s Republic of China

    Directory of Open Access Journals (Sweden)

    Shi W

    2014-12-01

    Full Text Available Wenhao Shi,1–3 Jinliang Wang,4,5 Yan Lin,4,5 Jianhui Geng,4,5 Haixia Wang,4,5 Yueqin Gong,4,5 Huaxu Liu,1,4,5 Furen Zhang1–4 1Shandong Provincial Institute of Dermatology and Venereology, Shandong Academy of Medical Sciences, 2Shandong Provincial Key Lab for Dermatovenereology, 3School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, 4Shandong Provincial Hospital for Skin Diseases, Shandong University, 5Shandong Provincial Medical Center for Dermatovenereology, Jinan, Shandong, People’s Republic of China Background: Currently, 595 nm pulsed dye laser (PDL therapy is offered as one of the effective treatments of port wine stains (PWSs. However, the efficacy of PDL differs in different populations.Objective: The purpose of the study was to investigate the efficacy, and related factors, of 595 nm PDL in the treatment of PWSs in Chinese patients with skin type III to IV. Methods: A total of 848 cases that were treated with PDL were enrolled and analyzed in this study. An independent dermatologist evaluated these lesions according to the before and after photographs.Results: The response rate (RR of all the 848 PWS patients was 69.9%, within which the cure rate was 6.3%. The patients aged ≤1 year had the highest RR (93.9%, whereas those treated after age 50 reacted the worst (RR =25%. We analyzed the anatomical distribution of the lesion and found that the temporal region had the highest lesion clearance (RR =75.3%, while the extremities had the lowest clearance (RR =44.5%. Compared with the patients whose lesion size was larger than 80 cm2, the patients with small lesion size, of 0–20 cm2, had better clinical effect (RR =73.8% vs 53.2%. The reactions of the patients with hyperplastic lesion were worse than those with red patches (RR =36.4% vs 71.7%. As well, increasing treatment numbers could achieve higher clearance rates (P=0.005.Conclusion: The PDL had a relatively high RR but a low clearance

  13. Evaluation of droplet size distributions using univariate and multivariate approaches.

    Science.gov (United States)

    Gaunø, Mette Høg; Larsen, Crilles Casper; Vilhelmsen, Thomas; Møller-Sonnergaard, Jørn; Wittendorff, Jørgen; Rantanen, Jukka

    2013-01-01

    Pharmaceutically relevant material characteristics are often analyzed based on univariate descriptors instead of utilizing the whole information available in the full distribution. One example is droplet size distribution, which is often described by the median droplet size and the width of the distribution. The current study was aiming to compare univariate and multivariate approach in evaluating droplet size distributions. As a model system, the atomization of a coating solution from a two-fluid nozzle was investigated. The effect of three process parameters (concentration of ethyl cellulose in ethanol, atomizing air pressure, and flow rate of coating solution) on the droplet size and droplet size distribution using a full mixed factorial design was used. The droplet size produced by a two-fluid nozzle was measured by laser diffraction and reported as volume based size distribution. Investigation of loading and score plots from principal component analysis (PCA) revealed additional information on the droplet size distributions and it was possible to identify univariate statistics (volume median droplet size), which were similar, however, originating from varying droplet size distributions. The multivariate data analysis was proven to be an efficient tool for evaluating the full information contained in a distribution.

  14. Lasers: principles, applications and energetic measures

    International Nuclear Information System (INIS)

    Subran, C.; Sagaut, J.; Lapointe, S.

    2009-01-01

    After having recalled the principles of a laser and the properties of the laser beam, the authors describe the following different types of lasers: solid state lasers, fiber lasers, semiconductor lasers, dye lasers and gas lasers. Then, their applications are given. Very high energy lasers can reproduce the phenomenon of nuclear fusion of hydrogen atoms. (O.M.)

  15. History and principle of lasers

    International Nuclear Information System (INIS)

    Townes, Ch.H.; Schwob, C.; Julien, J.; Forget, S.; Robert-Philip, I.; Balcou, Ph.

    2010-01-01

    In the first article C.H. Townes, the inventor of the maser, describes the work and ideas that led to the invention of the laser. The second article explains how a laser operate and the third article reviews the main different types of laser: solid lasers, gas lasers, diode lasers and dye lasers

  16. Response of two-phase droplets to intense electromagnetic radiation

    Science.gov (United States)

    Spann, James F.; Maloney, Daniel J.; Lawson, William F.; Casleton, Kent H.

    1993-01-01

    The response of two-phase droplets to intense radiant heating is studied to determine the incident power that is required for causing explosive boiling in the liquid phase. The droplets studied consist of strongly absorbing coal particles dispersed in a weakly absorbing water medium. Experiments are performed by confining droplets (radii of 37, 55, and 80 microns) electrodynamically and irradiating them from two sides with pulsed laser beams. Emphasis is placed on the transition region from accelerated droplet vaporization to droplet superheating and explosive boiling. The time scale observed for explosive boiling is more than 2 orders of magnitude longer than published values for pure liquids. The delayed response is the result of energy transfer limitations between the absorbing solid phase and the surrounding liquid.

  17. Retrospective analysis of the treatment of melasma lesions exhibiting increased vascularity with the 595-nm pulsed dye laser combined with the 1927-nm fractional low-powered diode laser.

    Science.gov (United States)

    Geddes, Elizabeth R C; Stout, Ashlyn B; Friedman, Paul M

    2017-01-01

    Melasma presents a significant challenge to laser surgeons. Aggressive treatments often result in rebound melasma or post-inflammatory pigmentary alteration. Recent reports suggest melasma pathogenesis may have a vascular component. Spectrocolorimetry can detect subtle or sub-clinical telangiectatic erythema within melasma lesions. For certain patients identified by spectrocolorimetry, effective melasma treatment may include vascular-targeted therapy together with pigment-specific treatment modalities. Such combined therapies may reduce the likelihood of melasma recurrence. To evaluate the efficacy of treating melasma lesions exhibiting subtle or sub-clinical telangiectatic erythema with the 595-nm pulsed dye laser (PDL) combined with the 1927-nm fractional low-powered diode laser (FDL). A retrospective review was performed over a 2-year period as follows. Evaluated patients (n = 11) include 10 women and 1 man, average age of 38.7 years, and Fitzpatrick skin types II-IV. Each patient exhibited melasma lesions with subtle or sub-clinical telangiectatic erythema identified by spectrocolorimetry. Each underwent a series of treatments (average of four) at approximate 4-6 week intervals of the PDL followed by the FDL. Treatments were performed same-day, sequentially, with 10-15 minute interim time allowance for skin cooling. The following PDL parameters were utilized: 10 mm spot, 10-20 ms pulse duration, 7.5-8.5 J/cm 2 fluence, 30/30 DCD. Eight passes with the FDL (Clear + Brilliant ® Permea™, Solta Medical, Hayward, CA) were then performed utilizing a "low" treatment level. Clinical endpoint was mild erythema and edema. Patients were encouraged to practice strict photoprotection and apply topical skin lightening agents, but compliance was not measured. An independent physician evaluated photographs taken at baseline and at follow-up after last treatment session (average follow-up of 96 days). A quartile improvement score was used to grade the

  18. Bioprinting: Functional droplet networks

    Science.gov (United States)

    Durmus, Naside Gozde; Tasoglu, Savas; Demirci, Utkan

    2013-06-01

    Tissue-mimicking printed networks of droplets separated by lipid bilayers that can be functionalized with membrane proteins are able to spontaneously fold and transmit electrical currents along predefined paths.

  19. Nano-dyeing

    Directory of Open Access Journals (Sweden)

    Ning Cui-Juan

    2016-01-01

    Full Text Available Dyeing nanofibers is a frontier of both modern textile engineering and nanotechnology. This paper suggest a feasible method for dyeing nanofibers with a natural red (Roselle Calyx by bubble electrospinning. Reactive dye (Red S3B and acid dye (Red 2B were also used in the experiment for comparison. The dyeing process was finished during the spinning process.

  20. Lasers '90: Proceedings of the 13th International Conference on Lasers and Applications, San Diego, CA, Dec. 10-14, 1990

    International Nuclear Information System (INIS)

    Harris, D.G.; Herbelin, J.

    1991-01-01

    The general topics considered are: x-ray lasers; FELs; solid state lasers; techniques and phenomena of ultrafast lasers; optical filters and free space laser communications; discharge lasers; tunable lasers; applications of lasers in medicine and surgery; lasers in materials processing; high power lasers; dynamics gratings, wave mixing, and holography; up-conversion lasers; lidar and laser radar; laser resonators; excimer lasers; laser propagation; nonlinear and quantum optics; blue-green technology; imaging; laser spectroscopy; chemical lasers; dye lasers; and lasers in chemistry

  1. In Vivo Investigation of the Safety and Efficacy of Pulsed Dye Laser with Two Spot Sizes in Port-Wine Stain Treatment: A Prospective Side-by-Side Comparison.

    Science.gov (United States)

    Yu, Wenxin; Ying, Hanru; Chen, Yijie; Qiu, Yajing; Chen, Hui; Jin, Yunbo; Yang, Xi; Wang, Tianyou; Ma, Gang; Lin, Xiaoxi

    2017-09-01

    Pulsed dye laser (PDL) with 7 and 10 mm spot sizes is widely used on a regular basis for the treatment of port-wine stain (PWS). No studies have reported on the differences in efficacy outcomes resulting from the use of different laser spot sizes in the treatment of PWS by PDL. Thus, an in vivo investigation into the differences in safety and efficacy of treatment between two spot sizes (7 vs. 10 mm) of PWS by PDL was conducted. A total of 35 PWS patients underwent three treatment sessions by using a 595 nm wavelength PDL (Vbeam ® , Candela Corp) with two laser settings: (1) 7 mm spot size, radiant exposure of 12 J/cm 2 and (2) 10 mm spot size, radiant exposure of 10 J/cm 2 . Cryogen spray cooling and 1.5 msec pulse duration were applied. Therapeutic outcomes were evaluated by visual and chromametric evaluation 3 months after the final treatment. Average blanching rates were 34.03% and 36.51% at sites treated by PDL with 7 and 10 mm laser spot sizes, respectively (p spot sizes were similar. PDL with a 10 mm laser spot size is more efficacious with lower radiant exposure than PDL with a 7 mm spot size; it can also reduce the treatment time.

  2. Droplet based microfluidics

    International Nuclear Information System (INIS)

    Seemann, Ralf; Brinkmann, Martin; Pfohl, Thomas; Herminghaus, Stephan

    2012-01-01

    Droplet based microfluidics is a rapidly growing interdisciplinary field of research combining soft matter physics, biochemistry and microsystems engineering. Its applications range from fast analytical systems or the synthesis of advanced materials to protein crystallization and biological assays for living cells. Precise control of droplet volumes and reliable manipulation of individual droplets such as coalescence, mixing of their contents, and sorting in combination with fast analysis tools allow us to perform chemical reactions inside the droplets under defined conditions. In this paper, we will review available drop generation and manipulation techniques. The main focus of this review is not to be comprehensive and explain all techniques in great detail but to identify and shed light on similarities and underlying physical principles. Since geometry and wetting properties of the microfluidic channels are crucial factors for droplet generation, we also briefly describe typical device fabrication methods in droplet based microfluidics. Examples of applications and reaction schemes which rely on the discussed manipulation techniques are also presented, such as the fabrication of special materials and biophysical experiments.

  3. OCS in He droplets

    Energy Technology Data Exchange (ETDEWEB)

    Grebenev, V.

    2000-06-01

    Phenomenon of superfluidity of para-hydrogen (pH{sub 2}){sub 1-17} and helium {sup 4}He{sub 1-7000} systems doped with an OCS chromophore molecule was investigated in this work. The study of such systems became possible after the development of the depletion spectroscopy technique in helium droplets. The droplets can be easily created and doped with up to 100 particles such as OCS, para-hydrogen or ortho-hydrogen molecules and {sup 4}He atoms. The measured infrared depletion spectra give the information about the temperature of the droplets and their aggregate state. The depletion spectrum of OCS in pure {sup 4}He droplets was comprehensively studied. The rovibrational OCS spectrum shows well resolved narrow lines. The spectrum is shifted to the red relative to the corresponding gas phase spectrum and the rotational constant of OCS in {sup 4}He droplet is three times smaller than that for free molecule. Different models of OCS rotation in the helium environment were discussed. It was shown that the shapes of the rovibrational lines are defined mainly by inhomogeneous broadening due to the droplet size distribution. The sub-rotational structure of the OCS rovibrational lines was revealed in microwave-infrared double resonance experiments. This structure arises due to the interaction of the OCS with the He environment. However, the information obtained in the experiments was not enough to understand the nature of this interaction. (orig.)

  4. Structural morphology of acoustically levitated and heated nanosilica droplet

    International Nuclear Information System (INIS)

    Kumar, Ranganathan; Tijerino, Erick; Saha, Abhishek; Basu, Saptarshi

    2010-01-01

    We study the vaporization and precipitation dynamics of a nanosilica encapsulated water droplet by levitating it acoustically and heating it with a CO 2 laser. For all concentrations, we observe three phases: solvent evaporation, surface agglomeration, and precipitation leading to bowl or ring shaped structures. At higher concentrations, ring reorientation and rotation are seen consistently. The surface temperature from an infrared camera is seen to be dependent on the final geometrical shape of the droplet and its rotation induced by the acoustic field of the levitator. With nonuniform particle distribution, these structures can experience rupture which modifies the droplet rotational speed.

  5. Theoretical analysis for the optical deformation of emulsion droplets.

    Science.gov (United States)

    Tapp, David; Taylor, Jonathan M; Lubansky, Alex S; Bain, Colin D; Chakrabarti, Buddhapriya

    2014-02-24

    We propose a theoretical framework to predict the three-dimensional shapes of optically deformed micron-sized emulsion droplets with ultra-low interfacial tension. The resulting shape and size of the droplet arises out of a balance between the interfacial tension and optical forces. Using an approximation of the laser field as a Gaussian beam, working within the Rayleigh-Gans regime and assuming isotropic surface energy at the oil-water interface, we numerically solve the resulting shape equations to elucidate the three-dimensional droplet geometry. We obtain a plethora of shapes as a function of the number of optical tweezers, their laser powers and positions, surface tension, initial droplet size and geometry. Experimentally, two-dimensional droplet silhouettes have been imaged from above, but their full side-on view has not been observed and reported for current optical configurations. This experimental limitation points to ambiguity in differentiating between droplets having the same two-dimensional projection but with disparate three-dimensional shapes. Our model elucidates and quantifies this difference for the first time. We also provide a dimensionless number that indicates the shape transformation (ellipsoidal to dumbbell) at a value ≈ 1.0, obtained by balancing interfacial tension and laser forces, substantiated using a data collapse.

  6. Analytical detection techniques for droplet microfluidics—A review

    International Nuclear Information System (INIS)

    Zhu, Ying; Fang, Qun

    2013-01-01

    Graphical abstract: -- Highlights: •This is the first review paper focused on the analytical techniques for droplet-based microfluidics. •We summarized the analytical methods used in droplet-based microfluidic systems. •We discussed the advantage and disadvantage of each method through its application. •We also discuss the future development direction of analytical methods for droplet-based microfluidic systems. -- Abstract: In the last decade, droplet-based microfluidics has undergone rapid progress in the fields of single-cell analysis, digital PCR, protein crystallization and high throughput screening. It has been proved to be a promising platform for performing chemical and biological experiments with ultra-small volumes (picoliter to nanoliter) and ultra-high throughput. The ability to analyze the content in droplet qualitatively and quantitatively is playing an increasing role in the development and application of droplet-based microfluidic systems. In this review, we summarized the analytical detection techniques used in droplet systems and discussed the advantage and disadvantage of each technique through its application. The analytical techniques mentioned in this paper include bright-field microscopy, fluorescence microscopy, laser induced fluorescence, Raman spectroscopy, electrochemistry, capillary electrophoresis, mass spectrometry, nuclear magnetic resonance spectroscopy, absorption detection, chemiluminescence, and sample pretreatment techniques. The importance of analytical detection techniques in enabling new applications is highlighted. We also discuss the future development direction of analytical detection techniques for droplet-based microfluidic systems

  7. Studies of the plasma droplet accelerator scheme

    International Nuclear Information System (INIS)

    Mori, W.B.; Joshi, C.; Dawson, J.M.; Lee, K.; Forslund, D.W.; Kindel, J.M.

    1985-01-01

    In the plasma droplet accelerator scheme, proposed by R. Palmer, a sequence of liquid micro-spheres generated by a jet printer are ionized by an incoming intense laser. The hope is that the micro-spheres now acting as conducting balls will allow efficient coupling of the incoming laser radiation into an accelerating mode. Motivated by this the authors have carried out 2D, particle simulations in order to answer some of the plasma physics questions hitherto unaddressed. In particular they find that at least for laser intensities exceeding v 0 /c=0.03 (/sup ∼/10 13 w/cm 2 for a CO 2 laser), the incident laser light is rather efficiently absorbed in a hot electron distribution. Up to 70% of the incident energy can be absorbed by these electrons which rapidly expand and fill the vacuum space between the microspheres with a low density plasma. These results indicate that it is advisable to stay clear of plasma formation and thus put on an upper limit on the maximum surface fields that can be tolerated in the droplet-accelerator scheme

  8. Studies of the plasma droplet accelerator scheme

    International Nuclear Information System (INIS)

    Mori, W.B.; Dawson, J.M.; Forslund, D.W.; Joshi, C.; Kindel, J.M.; Lee, K.

    1985-01-01

    In the plasma droplet accelerator scheme, proposed by R. Palmer, a sequence of liquid micro-spheres generated by a jet printer are ionized by an incoming intense laser. The hope is that the micro-spheres now acting as conducting balls will allow efficient coupling of the incoming laser radiation into an accelerating mode. Motivated by this we have carried out 2D, particle simulations in order to answer some of the plasma physics questions hitherto unaddressed. In particular we find that at least for laser intensities exceeding v /SUB o/ /c=0.03 ( about10 13 w/cm 2 for a CO 2 laser), the incident laser light is rather efficiently absorbed in a hot electron distribution. Up to 70% of the incident energy can be absorbed by these electrons which rapidly expand and fill the vacuum space between the microspheres with a low density plasma. These results indicate that it is advisable to stay clear of plasma formation and thus put on an upper limit on the maximum surface fields that can be tolerated in the droplet-accelerator scheme

  9. Hair dye poisoning

    Science.gov (United States)

    Hair tint poisoning ... Different types of hair dye contain different harmful ingredients. The harmful ingredients in permanent dyes are: Naphthylamine Other aromatic amino compounds Phenylenediamines Toluene ...

  10. Photochemistry of triarylmethane dyes bound to proteins

    Science.gov (United States)

    Indig, Guilherme L.

    1996-04-01

    Triarylmethanes represent a class of cationic dyes whose potential as photosensitizers for use in photodynamic therapy of neoplastic diseases has never been comprehensively evaluated. Here, the laser-induced photodecomposition of three triarylmethane dyes, crystal violet, ethyl violet, and malachite green, non-covalently bound to bovine serum albumin (a model biological target) was investigated. Upon laser excitation at 532 nm, the bleaching of the corresponding dye-protein molecular complexes follows spectroscopic patterns that suggest the formation of reduced forms of the dyes as major reaction photoproducts. That implies that an electron or hydrogen atom transfer from the protein to the dye's moiety within the guest-host complex is the first step of the photobleaching process. Since the availability of dissolved molecular oxygen was not identified as a limiting factor for the phototransformations to occur, these dyes can be seen as potential phototherapeutic agents for use in hypoxic areas of tumors. These triarylmethane dyes strongly absorb at relatively long wavelengths (absorption maximum around 600 nm; (epsilon) max approximately equals 105 M-1 cm-1), and only minor changes in their absorption characteristics are observed upon binding to the protein. However the binding event leads to a remarkable increase in their fluorescence quantum yield and photoreactivity.

  11. Uniform silica nanoparticles encapsulating two-photon absorbing fluorescent dye

    International Nuclear Information System (INIS)

    Wu Weibing; Liu Chang; Wang Mingliang; Huang Wei; Zhou Shengrui; Jiang Wei; Sun Yueming; Cui Yiping; Xu Chunxinag

    2009-01-01

    We have prepared uniform silica nanoparticles (NPs) doped with a two-photon absorbing zwitterionic hemicyanine dye by reverse microemulsion method. Obvious solvatochromism on the absorption spectra of dye-doped NPs indicates that solvents can partly penetrate into the silica matrix and then affect the ground and excited state of dye molecules. For dye-doped NP suspensions, both one-photon and two-photon excited fluorescence are much stronger and recorded at shorter wavelength compared to those of free dye solutions with comparative overall dye concentration. This behavior is possibly attributed to the restricted twisted intramolecular charge transfer (TICT), which reduces fluorescence quenching when dye molecules are trapped in the silica matrix. Images from two-photon laser scanning fluorescence microscopy demonstrate that the dye-doped silica NPs can be actively uptaken by Hela cells with low cytotoxicity. - Graphical abstract: Water-soluble silica NPs doped with a two-photon absorbing zwitterionic hemicyanine dye were prepared. They were found of enhanced one-photon and two-photon excited fluorescence compared to free dye solutions. Images from two-photon laser scanning fluorescence microscopy demonstrate that the dye-doped silica NPs can be actively uptaken by Hela cells.

  12. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Energy Technology Data Exchange (ETDEWEB)

    Nischkauer, Winfried [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria); Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Vanhaecke, Frank [Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Bernacchi, Sébastien; Herwig, Christoph [Institute of Chemical Engineering, Vienna University of Technology, Vienna (Austria); Limbeck, Andreas, E-mail: Andreas.Limbeck@tuwien.ac.at [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria)

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL{sup −1} with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  13. Droplet-based microscale colorimetric biosensor for multiplexed DNA analysis via a graphene nanoprobe

    International Nuclear Information System (INIS)

    Xiang Xia; Luo Ming; Shi Liyang; Ji Xinghu; He Zhike

    2012-01-01

    Graphical abstract: With a microvalve manipulate technique combined with droplet platform, a microscale fluorescence-based colorimetric sensor for multiplexed DNA analysis is developed via a graphene nanoprobe. Highlights: ► A quantitative detection for multiplexed DNA is first realized on droplet platform. ► The DNA detection is relied on a simple fluorescence-based colorimetric method. ► GO is served as a quencher for two different DNA fluorescent probes. ► This present work provides a rapid, sensitive, visual and convenient detection tool for droplet biosensor. - Abstract: The development of simple and inexpensive DNA detection strategy is very significant for droplet-based microfluidic system. Here, a droplet-based biosensor for multiplexed DNA analysis is developed with a common imaging device by using fluorescence-based colorimetric method and a graphene nanoprobe. With the aid of droplet manipulation technique, droplet size adjustment, droplet fusion and droplet trap are realized accurately and precisely. Due to the high quenching efficiency of graphene oxide (GO), in the absence of target DNAs, the droplet containing two single-stranded DNA probes and GO shows dark color, in which the DNA probes are labeled carboxy fluorescein (FAM) and 6-carboxy-X-rhodamine (ROX), respectively. The droplet changes from dark to bright color when the DNA probes form double helix with the specific target DNAs leading to the dyes far away from GO. This colorimetric droplet biosensor exhibits a quantitative capability for simultaneous detection of two different target DNAs with the detection limits of 9.46 and 9.67 × 10 −8 M, respectively. It is also demonstrated that this biosensor platform can become a promising detection tool in high throughput applications with low consumption of reagents. Moreover, the incorporation of graphene nanoprobe and droplet technique can drive the biosensor field one more step to some extent.

  14. Tunable on chip optofluidic laser

    DEFF Research Database (Denmark)

    Bakal, Avraham; Vannahme, Christoph; Kristensen, Anders

    2015-01-01

    A chip scale tunable laser in the visible spectral band is realized by generating a periodic droplet array inside a microfluidic channel. Combined with a gain medium within the droplets, the periodic structure provides the optical feedback of the laser. By controlling the pressure applied to two...

  15. Chip-based droplet sorting

    Energy Technology Data Exchange (ETDEWEB)

    Beer, Neil Reginald; Lee, Abraham; Hatch, Andrew

    2017-11-21

    A non-contact system for sorting monodisperse water-in-oil emulsion droplets in a microfluidic device based on the droplet's contents and their interaction with an applied electromagnetic field or by identification and sorting.

  16. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  17. Investigation on ionic states of 1,2-Dipalmitoyl-sn-glycero-3-phosphorylcholine (DPPC) using organic laser dyes: A FRET study

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Arpan Datta; Saha, Jaba; Dey, D.; Bhattacharjee, D.; Hussain, Syed Arshad, E-mail: sa_h153@hotmail.com

    2017-05-15

    Fluorescence Resonance Energy Transfer (FRET) between two organic dyes Fluorescein and Rhodamine 6G were successfully investigated in aqueous solution in presence and absence of 1,2-Dipalmitoyl-sn-glycero-3-phosphorylcholine (DPPC) at different pH. Spectroscopic studies suggest that both the dyes were present mainly as monomer in solution. FRET occurred from Fluorescein to Rhodamine 6G in solutions. Energy transfer efficiency increases in presence of DPPC and the maximum efficiency was 59.3% when the concentration of DPPC was 1.4×10{sup −4} M at ambient condition. pH plays a crucial role in this investigation as the energy transfer efficiency was found to change in presence of DPPC at different pH. It has been demonstrated that with proper calibration it is possible to use the present system under investigation to realize various ionic states of DPPC by observing the change in FRET efficiency between these two dyes. - Graphical abstract: Electrostatic interaction between anionic Flu and cationic R6G molecules in presence and absence of DPPC at different pH. Here pH of DPPC was changed, not the pH of individual dyes.

  18. Hydrodynamics of a quark droplet

    DEFF Research Database (Denmark)

    Bjerrum-Bohr, Johan J.; Mishustin, Igor N.; Døssing, Thomas

    2012-01-01

    We present a simple model of a multi-quark droplet evolution based on the hydrodynamical description. This model includes collective expansion of the droplet, effects of the vacuum pressure and surface tension. The hadron emission from the droplet is described following Weisskopf's statistical...

  19. Measurement of droplet vaporization rate enhancement caused by acoustic disturbances

    Science.gov (United States)

    Anderson, T. J.; Winter, M.

    1992-10-01

    Advanced laser diagnostics are being applied to quantify droplet vaporization enhancement in the presence of acoustic fields which can lead to instability in liquid-fueled rockets. While models have been developed to describe the interactions between subcritical droplet vaporization and acoustic fields in the surrounding gases, they have not been verified experimentally. In the super critical environment of a rocket engine combustor, little is understood about how the injected fluid is distributed. Experiments in these areas have been limited because of the lack of diagnostic techniques capable of providing quantitative results. Recently, however, extremely accurate vaporization rate measurements have been performed on droplets in a subcritical environment using morphology-dependent resonances (MDR's) in which fluorescence from an individual droplet provides information about its diameter. Initial measurements on methanol droplets behind a pressure pulse with a pressure ratio of 1.2 indicated that the evaporation rate in the first few microsec after wave passage was extremely high. Subsequent measurements have been made to validate these results using MDR's acquired from similarly-sized droplets using a pulse with a 1.1 pressure ratio. A baseline measurement was also made using a non evaporative fluid under similar Weber and Reynolds number conditions. The MDR technique employed for these measurements is explained and the facilities are described. The evaporation measurement results are shown and the rates observed from different droplet materials and different wave strengths are compared.

  20. Selfbound quantum droplets

    Science.gov (United States)

    Langen, Tim; Wenzel, Matthias; Schmitt, Matthias; Boettcher, Fabian; Buehner, Carl; Ferrier-Barbut, Igor; Pfau, Tilman

    2017-04-01

    Self-bound many-body systems are formed through a balance of attractive and repulsive forces and occur in many physical scenarios. Liquid droplets are an example of a self-bound system, formed by a balance of the mutual attractive and repulsive forces that derive from different components of the inter-particle potential. On the basis of the recent finding that an unstable bosonic dipolar gas can be stabilized by a repulsive many-body term, it was predicted that three-dimensional self-bound quantum droplets of magnetic atoms should exist. Here we report on the observation of such droplets using dysprosium atoms, with densities 108 times lower than a helium droplet, in a trap-free levitation field. We find that this dilute magnetic quantum liquid requires a minimum, critical number of atoms, below which the liquid evaporates into an expanding gas as a result of the quantum pressure of the individual constituents. Consequently, around this critical atom number we observe an interaction-driven phase transition between a gas and a self-bound liquid in the quantum degenerate regime with ultracold atoms.

  1. Anaerobic azo dye reduction

    OpenAIRE

    Zee, van der, F.P.

    2002-01-01

    Azo dyes, aromatic moieties linked together by azo (-N=N-) chromophores, represent the largest class of dyes used in textile-processing and other industries. The release of these compounds into the environment is undesirable, not only because of their colour, but also because many azo dyes and their breakdown products are toxic and/or mutagenic to life. To remove azo dyes from wastewater, a biological treatment strategy based on anaerobic reduction of the azo dye...

  2. Cavitation-induced fragmentation of an acoustically-levitated droplet

    Science.gov (United States)

    Gonzalez Avila, Silvestre Roberto; Ohl, Claus-Dieter

    2015-12-01

    In this paper we investigate the initial sequence of events that lead to the fragmentation of a millimetre sized water droplets when interacting with a focused ns-laser pulse. The experimental results show complex processes that result from the reflection of an initial shock wave from plasma generation with the soft boundary of the levitating droplet; furthermore, when the reflected waves from the walls of the droplet refocus they leave behind a trail of microbubbles that later act as cavitation inception regions. Numerical simulations of a shock wave impacting and reflecting from a soft boundary are also reported; the simulated results show that the lowest pressure inside the droplet occurs at the equatorial plane. The results of the numerical model display good agreement with the experimental results both in time and in space.

  3. Cavitation-induced fragmentation of an acoustically-levitated droplet

    International Nuclear Information System (INIS)

    Avila, Silvestre Roberto Gonzalez; Ohl, Claus-Dieter

    2015-01-01

    In this paper we investigate the initial sequence of events that lead to the fragmentation of a millimetre sized water droplets when interacting with a focused ns-laser pulse. The experimental results show complex processes that result from the reflection of an initial shock wave from plasma generation with the soft boundary of the levitating droplet; furthermore, when the reflected waves from the walls of the droplet refocus they leave behind a trail of microbubbles that later act as cavitation inception regions. Numerical simulations of a shock wave impacting and reflecting from a soft boundary are also reported; the simulated results show that the lowest pressure inside the droplet occurs at the equatorial plane. The results of the numerical model display good agreement with the experimental results both in time and in space. (paper)

  4. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL - 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  5. Electrical actuation of dielectric droplets

    International Nuclear Information System (INIS)

    Kumari, N; Bahadur, V; Garimella, S V

    2008-01-01

    Electrical actuation of liquid droplets at the microscale offers promising applications in the fields of microfluidics and lab-on-a-chip devices. Much prior research has targeted the electrical actuation of electrically conducting liquid droplets; however, the actuation of dielectric droplets has remained relatively unexplored, despite the advantages associated with the use of a dielectric droplet. This paper presents modeling and experimental results on the electrical actuation of dielectric droplets between two flat plates. A first-order analytical model, based on the energy-minimization principle, is developed to estimate the electrical actuation force on a dielectric droplet as it moves between two flat plates. Two versions of this analytical model are benchmarked for their suitability and accuracy against a detailed numerical model. The actuation force prediction is then combined with available semi-analytical expressions for predicting the forces opposing droplet motion to develop a model that predicts transient droplet motion under electrical actuation. Electrical actuation of dielectric droplets is experimentally demonstrated by moving transformer oil droplets between two flat plates under the influence of an actuation voltage. Droplet velocities and their dependence on the plate spacing and the applied voltage are experimentally measured and showed reasonable agreement with predictions from the models developed

  6. A novel method for the synthesis of coumarin laser dyes derived from 3-(1H-benzoimidazol-2-yl coumarin-2-one under microwave irradiation

    Directory of Open Access Journals (Sweden)

    Ghasem Bakhtiari

    2014-12-01

    Full Text Available We want to achieve the synthesis of 3-(1H-benzoimidazol-2-yl-7-(diethylamino coumarin-2-one (1, 3-(1H-benzoimidazol-2-yl-7-(dimethylamino coumarin-2-one (2, 3-(1H-benzoimidazol-2-yl coumarin-2-one (3 that are important dyes in industries (Soko owska et al., 2001. Methods for the synthesis of some of these compounds have been the title in some pervious patents, but enough information about separation and purification of them was not clearly indicated. We carried out several methods for the synthesis of the mentioned compound and purification with different yields. Now, we can synthesise these dyes under microwave irradiation in solid phase and solvent free methods with 80% yield, which is a high and remarkable percentage.

  7. The analysis of dyes in ball point pen inks on single paper fibres using laser desorption ionisation time of flight mass spectrometry (LDI-TOFMS).

    Science.gov (United States)

    Matthews, Broderick; Walker, G Stewart; Kobus, Hilton; Pigou, Paul; Bird, Carolyne; Smith, Glyn

    2011-06-15

    An important requisite for the forensic analysis of inks on documents is that damage to the document is avoided or minimised. This paper describes a technique for dye identification in ballpoint pen inks using LDI-TOFMS on single ink bearing paper fibres and its application to a case. A single ink bearing paper fibre can be prised from the surface of the document under a stereo microscope and presented to the instrument for analysis without further treatment. This sampling process causes imperceptible damage to the surface of the document. Clear mass spectrometric identification of the ink dyes is obtained. A case example is provided to illustrate the practical application of the technique. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Optimizing cell viability in droplet-based cell deposition

    NARCIS (Netherlands)

    Hendriks, Jan; Visser, C.W.; Henke, S.J.; Leijten, Jeroen Christianus Hermanus; Saris, Daniël B.F.; Sun, Chao; Lohse, Detlef; Karperien, Hermanus Bernardus Johannes

    2015-01-01

    Biofabrication commonly involves the use of liquid droplets to transport cells to the printed structure. However, the viability of the cells after impact is poorly controlled and understood, hampering applications including cell spraying, inkjet bioprinting, and laser-assisted cell transfer. Here,

  9. Droplets and sprays

    CERN Document Server

    Sazhin, Sergei

    2014-01-01

    Providing a clear and systematic description of droplets and spray dynamic models, this book maximises reader insight into the underlying physics of the processes involved, outlines the development of new physical and mathematical models, and broadens understanding of interactions between the complex physical processes which take place in sprays. Complementing approaches based on the direct application of computational fluid dynamics (CFD), Droplets and Sprays treats both theoretical and practical aspects of internal combustion engine process such as the direct injection of liquid fuel, subcritical heating and evaporation. Includes case studies that illustrate the approaches relevance to automotive applications,  it is also anticipated that the described models can find use in other areas such as in medicine and environmental science.

  10. Performance of droplet generator and droplet collector in liquid droplet radiator under microgravity

    Science.gov (United States)

    Totani, T.; Itami, M.; Nagata, H.; Kudo, I.; Iwasaki, A.; Hosokawa, S.

    2002-06-01

    The Liquid Droplet Radiator (LDR) has an advantage over comparable conventional radiators in terms of the rejected heat power-weight ratio. Therefore, the LDR has attracted attention as an advanced radiator for high-power space systems that will be prerequisite for large space structures. The performance of the LDR under microgravity condition has been studied from the viewpoint of operational space use of the LDR in the future. In this study, the performances of a droplet generator and a droplet collector in the LDR are investigated using drop shafts in Japan: MGLAB and JAMIC. As a result, it is considered that (1) the droplet generator can produce uniform droplet streams in the droplet diameter range from 200 to 280 [µm] and the spacing range from 400 to 950 [µm] under microgravity condition, (2) the droplet collector with the incidence angle of 35 degrees can prevent a uniform droplet stream, in which droplet diameter is 250 [µm] and the velocity is 16 [m/s], from splashing under microgravity condition, whereas splashes may occur at the surface of the droplet collector in the event that a nonuniform droplet stream collides against it.

  11. New droplet model developments

    International Nuclear Information System (INIS)

    Dorso, C.O.; Myers, W.D.; Swiatecki, W.J.; Moeller, P.; Treiner, J.; Weiss, M.S.

    1985-09-01

    A brief summary is given of three recent contributions to the development of the Droplet Model. The first concerns the electric dipole moment induced in octupole deformed nuclei by the Coulomb redistribution. The second concerns a study of squeezing in nuclei and the third is a study of the improved predictive power of the model when an empirical ''exponential'' term is included. 25 refs., 3 figs

  12. Acoustic droplet vaporization of vascular droplets in gas embolotherapy

    Science.gov (United States)

    Bull, Joseph

    2016-11-01

    This work is primarily motivated by a developmental gas embolotherapy technique for cancer treatment. In this methodology, infarction of tumors is induced by selectively formed vascular gas bubbles that arise from the acoustic vaporization of vascular droplets. Additionally, micro- or nano-droplets may be used as vehicles for localized drug delivery, with or without flow occlusion. In this talk, we examine the dynamics of acoustic droplet vaporization through experiments and theoretical/computational fluid mechanics models, and investigate the bioeffects of acoustic droplet vaporization on endothelial cells and in vivo. Functionalized droplets that are targeted to tumor vasculature are examined. The influence of fluid mechanical and acoustic parameters, as well as droplet functionalization, is explored. This work was supported by NIH Grant R01EB006476.

  13. Optical calorimetry in microfluidic droplets.

    Science.gov (United States)

    Chamoun, Jacob; Pattekar, Ashish; Afshinmanesh, Farzaneh; Martini, Joerg; Recht, Michael I

    2018-05-29

    A novel microfluidic calorimeter that measures the enthalpy change of reactions occurring in 100 μm diameter aqueous droplets in fluoropolymer oil has been developed. The aqueous reactants flow into a microfluidic droplet generation chip in separate fluidic channels, limiting contact between the streams until immediately before they form the droplet. The diffusion-driven mixing of reactants is predominantly restricted to within the droplet. The temperature change in droplets due to the heat of reaction is measured optically by recording the reflectance spectra of encapsulated thermochromic liquid crystals (TLC) that are added to one of the reactant streams. As the droplets travel through the channel, the spectral characteristics of the TLC represent the internal temperature, allowing optical measurement with a precision of ≈6 mK. The microfluidic chip and all fluids are temperature controlled, and the reaction heat within droplets raises their temperature until thermal diffusion dissipates the heat into the surrounding oil and chip walls. Position resolved optical temperature measurement of the droplets allows calculation of the heat of reaction by analyzing the droplet temperature profile over time. Channel dimensions, droplet generation rate, droplet size, reactant stream flows and oil flow rate are carefully balanced to provide rapid diffusional mixing of reactants compared to thermal diffusion, while avoiding thermal "quenching" due to contact between the droplets and the chip walls. Compared to conventional microcalorimetry, which has been used in this work to provide reference measurements, this new continuous flow droplet calorimeter has the potential to perform titrations ≈1000-fold faster while using ≈400-fold less reactants per titration.

  14. Polymer laser bio-sensors

    DEFF Research Database (Denmark)

    Kristensen, Anders; Vannahme, Christoph; Hermannsson, Pétur Gordon

    2014-01-01

    Organic dye based distributed feed-back lasers, featuring narrow linewidth and thus high quality spectral resolution, are used as highly sensitive refractive index sensors. The design, fabrication and application of the laser intra-cavity sensors are discussed....

  15. In vitro study of 960 nm high power diode laser applications in dental enamel, aided by the presence of a photoinitiator dye: scanning electron microscopy analysis

    International Nuclear Information System (INIS)

    Oliveira, Marcelo Vinicius de

    2002-06-01

    The objective of this study is to verify if a high power diode laser can effectively modify the morphology of an enamel surface, and if this can be done in a controlled fashion by changing the lasers parameters. Previous studies using SEM demonstrated that through irradiation with Nd:YAG laser (1064 nm) it is possible to modify the morphology of the dental surface in such way as to increase its resistance against caries decays. The desired procedures that should achieve a decrease of the index of caries decays and of its sequels are on a primary level, which means that action is necessary before the disease installs itself. In this study it was used for the first time a prototype of a high power diode laser operating at 960 nm, produced by the Laboratory of Development of Lasers of the Center for Lasers and Applications of the IPEN. This equipment can present several advantages as reliability, reduced size and low cost. The aim was establish parameters of laser irradiation that produce the desired effects wanted in the enamel and protocols that guarantee its safety during application in dental hard tissues, protecting it of heating effects such as fissures and carbonization. (author)

  16. The Covalent Binding of Photosensitive Dyes to Monocrystalline Silicon Surface and Their Spectral Response

    Institute of Scientific and Technical Information of China (English)

    郭志新; 郝纪祥; 张祖训; 曹子祥

    1993-01-01

    A chemical method is proposed to bond photo-sensitive dyes directly to the surface of polished monocrystalline silicon. A methincyanine dye and a trimethincyanine dye have been bonded covalently onto silicon surface through Si—N bond, which are characterized by XPS technique and laser Raman spectra. Photovoltaic effect has been observed with the In/dye/n-Si sandwich devices composed of the dye-bonded n-Si wafers. Significant spectral response shows the characteristic absorptance maxima of the bonded dyes.

  17. Chemistry of Natural Dyes

    Indian Academy of Sciences (India)

    scientific principles, and the interaction between the dye and the dyed material is ... Dyes are classified based on their structure, source, method of application .... the right source that gives not only beautiful tones, but colourfast shades as well.

  18. Detection based on rainbow refractometry of droplet sphericity in liquid-liquid systems.

    Science.gov (United States)

    Lohner, H; Lehmann, P; Bauckhage, K

    1999-03-01

    The shape of droplets in liquid-liquid systems influences their mass and momentum transfer processes. The deviation from sphericity of rising droplets in liquid-liquid systems was investigated for different droplet sizes. Rainbow refractometry permits one to test, in this case, whether the use of laser-optical particle sizing will be correct or faulty. Since the assumption of spherical particle geometry is a general basis of laser-optical particle-sizing techniques such as rainbow refractometry or phase Doppler anemometry, deviation from the spherical shape results in a measuring error. A sphericity check based on rainbow refractometry is introduced.

  19. Dermatological laser treatment

    International Nuclear Information System (INIS)

    Moerk, N.J.; Austad, J.; Helland, S.; Thune, P.; Volden, G.; Falk, E.

    1991-01-01

    The article reviews the different lasers used in dermatology. Special emphasis is placed on the treatment of naevus flammeus (''portwine stain'') where lasers are the treatment of choice. Argon laser and pulsed dye laser are the main lasers used in vascular skin diseases, and the article focuses on these two types. Copper-vapour laser, neodymium-YAG laser and CO 2 laser are also presented. Information is provided about the availability of laser technology in the different health regions in Norway. 5 refs., 2 figs

  20. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

    International Nuclear Information System (INIS)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth

    2015-01-01

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape

  1. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

    Energy Technology Data Exchange (ETDEWEB)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth, E-mail: rsignorell@ethz.ch [Laboratory of Physical Chemistry, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich (Switzerland)

    2015-04-21

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

  2. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces.

    Science.gov (United States)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth

    2015-04-21

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

  3. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

    Science.gov (United States)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth

    2015-04-01

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

  4. Evaporation of inclined water droplets

    Science.gov (United States)

    Kim, Jin Young; Hwang, In Gyu; Weon, Byung Mook

    2017-01-01

    When a drop is placed on a flat substrate tilted at an inclined angle, it can be deformed by gravity and its initial contact angle divides into front and rear contact angles by inclination. Here we study on evaporation dynamics of a pure water droplet on a flat solid substrate by controlling substrate inclination and measuring mass and volume changes of an evaporating droplet with time. We find that complete evaporation time of an inclined droplet becomes longer as gravitational influence by inclination becomes stronger. The gravity itself does not change the evaporation dynamics directly, whereas the gravity-induced droplet deformation increases the difference between front and rear angles, which quickens the onset of depinning and consequently reduces the contact radius. This result makes the evaporation rate of an inclined droplet to be slow. This finding would be important to improve understanding on evaporation dynamics of inclined droplets. PMID:28205642

  5. Advances in solid state laser technology for space and medical applications

    Science.gov (United States)

    Byvik, C. E.; Buoncristiani, A. M.

    1988-01-01

    Recent developments in laser technology and their potential for medical applications are discussed. Gas discharge lasers, dye lasers, excimer lasers, Nd:YAG lasers, HF and DF lasers, and other commonly used lasers are briefly addressed. Emerging laser technology is examined, including diode-pumped lasers and other solid state lasers.

  6. Dynamic measurements and simulations of airborne picolitre-droplet coalescence in holographic optical tweezers

    International Nuclear Information System (INIS)

    Bzdek, Bryan R.; Reid, Jonathan P.; Collard, Liam; Sprittles, James E.; Hudson, Andrew J.

    2016-01-01

    We report studies of the coalescence of pairs of picolitre aerosol droplets manipulated with holographic optical tweezers, probing the shape relaxation dynamics following coalescence by simultaneously monitoring the intensity of elastic backscattered light (EBL) from the trapping laser beam (time resolution on the order of 100 ns) while recording high frame rate camera images (time resolution <10 μs). The goals of this work are to: resolve the dynamics of droplet coalescence in holographic optical traps; assign the origin of key features in the time-dependent EBL intensity; and validate the use of the EBL alone to precisely determine droplet surface tension and viscosity. For low viscosity droplets, two sequential processes are evident: binary coalescence first results from the overlap of the optical traps on the time scale of microseconds followed by the recapture of the composite droplet in an optical trap on the time scale of milliseconds. As droplet viscosity increases, the relaxation in droplet shape eventually occurs on the same time scale as recapture, resulting in a convoluted evolution of the EBL intensity that inhibits quantitative determination of the relaxation time scale. Droplet coalescence was simulated using a computational framework to validate both experimental approaches. The results indicate that time-dependent monitoring of droplet shape from the EBL intensity allows for robust determination of properties such as surface tension and viscosity. Finally, the potential of high frame rate imaging to examine the coalescence of dissimilar viscosity droplets is discussed.

  7. Simulation of water vapor condensation on LOX droplet surface using liquid nitrogen

    Science.gov (United States)

    Powell, Eugene A.

    1988-01-01

    The formation of ice or water layers on liquid oxygen (LOX) droplets in the Space Shuttle Main Engine (SSME) environment was investigated. Formulation of such ice/water layers is indicated by phase-equilibrium considerations under conditions of high partial pressure of water vapor (steam) and low LOX droplet temperature prevailing in the SSME preburner or main chamber. An experimental investigation was begun using liquid nitrogen as a LOX simulant. A monodisperse liquid nitrogen droplet generator was developed which uses an acoustic driver to force the stream of liquid emerging from a capillary tube to break up into a stream of regularly space uniformly sized spherical droplets. The atmospheric pressure liquid nitrogen in the droplet generator reservoir was cooled below its boiling point to prevent two phase flow from occurring in the capillary tube. An existing steam chamber was modified for injection of liquid nitrogen droplets into atmospheric pressure superheated steam. The droplets were imaged using a stroboscopic video system and a laser shadowgraphy system. Several tests were conducted in which liquid nitrogen droplets were injected into the steam chamber. Under conditions of periodic droplet formation, images of 600 micron diameter liquid nitrogen droplets were obtained with the stroboscopic video systems.

  8. Dynamic measurements and simulations of airborne picolitre-droplet coalescence in holographic optical tweezers

    Energy Technology Data Exchange (ETDEWEB)

    Bzdek, Bryan R.; Reid, Jonathan P., E-mail: j.p.reid@bristol.ac.uk [School of Chemistry, University of Bristol, Bristol BS8 1TS (United Kingdom); Collard, Liam [Department of Mathematics, University of Leicester, Leicester LE1 7RH (United Kingdom); Sprittles, James E. [Mathematics Institute, University of Warwick, Coventry CV4 7AL (United Kingdom); Hudson, Andrew J. [Department of Chemistry, University of Leicester, Leicester LE1 7RH (United Kingdom)

    2016-08-07

    We report studies of the coalescence of pairs of picolitre aerosol droplets manipulated with holographic optical tweezers, probing the shape relaxation dynamics following coalescence by simultaneously monitoring the intensity of elastic backscattered light (EBL) from the trapping laser beam (time resolution on the order of 100 ns) while recording high frame rate camera images (time resolution <10 μs). The goals of this work are to: resolve the dynamics of droplet coalescence in holographic optical traps; assign the origin of key features in the time-dependent EBL intensity; and validate the use of the EBL alone to precisely determine droplet surface tension and viscosity. For low viscosity droplets, two sequential processes are evident: binary coalescence first results from the overlap of the optical traps on the time scale of microseconds followed by the recapture of the composite droplet in an optical trap on the time scale of milliseconds. As droplet viscosity increases, the relaxation in droplet shape eventually occurs on the same time scale as recapture, resulting in a convoluted evolution of the EBL intensity that inhibits quantitative determination of the relaxation time scale. Droplet coalescence was simulated using a computational framework to validate both experimental approaches. The results indicate that time-dependent monitoring of droplet shape from the EBL intensity allows for robust determination of properties such as surface tension and viscosity. Finally, the potential of high frame rate imaging to examine the coalescence of dissimilar viscosity droplets is discussed.

  9. Droplet generation during core reflood

    International Nuclear Information System (INIS)

    Kocamustafaogullari, G.; De Jarlais, G.; Ishii, M.

    1983-01-01

    The process of entrainment and disintegration of liquid droplets by a flow of steam has considerable practical importance in calculating the effectivenes of the emergency core cooling system. Liquid entrainment is also important in determination of the critical heat flux point in general. Thus the analysis of the reflooding phase of a LOCA requires detailed knowledge of droplet size. Droplet size is mainly determined by the droplet generation mechanisms involved. To study these mechanisms, data generated in the PWR FLECHT SEASET series of experiments was analyzed. In addition, an experiment was performed in which the hydrodynamics of low quality post-CHF flow (inverted annular flow) were simulated in an adiabatic test section

  10. Photophysical properties, photodegradation characteristics, and lasing action for coumarin dye C540A in polymeric media

    Science.gov (United States)

    Jones, Guilford, II; Huang, Zhennian; Pacheco, Dennis P., Jr.; Russell, Jeffrey A.

    2004-07-01

    Tunable solid-state dye lasers operating in the blue-green spectral region are attractive for a variety of applications. An important consideration in assessing the viability of this technology is the service life of the gain medium, which is presently limited by dye photodegradation. In this study, solid polymeric samples consisting of the coumarin dye C540A in modified PMMA were subjected to controlled photodegradation tests. The excitation laser was a flashlamp-pumped dye laser operating at 440 nm with a pulse duration of 1 μs. A complementary set of data was obtained for dye in solution phase for comparison purposes. Photophysical properties of C540A in water solution of polymethacrylic acid (PMAA) have been investigated with a view to assess the suitability of the sequestering polymer (PMAA) as an effective additive to facilitate use of a water medium for highly efficient blue-green dye lasers. Lasing action of C540A in aqueous PMAA has been realized using flashlamp-pumped laser system, yielding excellent laser efficiencies superior to that achieved in ethanolic solutions with the same dye. Laser characterization of dye in media included measurement of laser threshold, slope efficiency, pulse duration and output wavelength.

  11. Tunable laser applications

    CERN Document Server

    Duarte, FJ

    2008-01-01

    Introduction F. J. Duarte Spectroscopic Applications of Tunable Optical Parametric Oscillators B. J. Orr, R. T. White, and Y. He Solid-State Dye Lasers Costela, I. García-Moreno, and R. Sastre Tunable Lasers Based on Dye-Doped Polymer Gain Media Incorporating Homogeneous Distributions of Functional Nanoparticles F. J. Duarte and R. O. James Broadly Tunable External-Cavity Semiconductor Lasers F. J. Duarte Tunable Fiber Lasers T. M. Shay and F. J. Duarte Fiber Laser Overview and Medical Applications

  12. Development of dynamic PIV for droplet jet flow

    International Nuclear Information System (INIS)

    Okamoto, K.; Hong, S. D.; Bi, W. T.; Sugii, Y.; Madarame, H.; Hayami, H.

    2003-01-01

    The Particle Image Velocimetry (PIV) can capture velocity vector fields with high spatial resolution. In this study, the Dynamic PIV system up to 10kHz temporal resolution was developed with combining the High-speed camera and high speed Laser with Double pulse option. The 1024 x 1024 pixel images with frame straddling were captured in 2kHz. Also, PIV data were measured in 512 x 256 pixel in 10kHz. The system had been applied to capture the water droplet flow. The transient characteristics of the droplet flow can be clearly captured using the developed Dynamic PIV System

  13. Lasers

    CERN Document Server

    Milonni, Peter W

    1988-01-01

    A comprehensive introduction to the operating principles and applications of lasers. Explains basic principles, including the necessary elements of classical and quantum physics. Provides concise discussions of various laser types including gas, solid state, semiconductor, and free electron lasers, as well as of laser resonators, diffraction, optical coherence, and many applications including holography, phase conjugation, wave mixing, and nonlinear optics. Incorporates many intuitive explanations and practical examples. Discussions are self-contained in a consistent notation and in a style that should appeal to physicists, chemists, optical scientists and engineers.

  14. Physical and chemical investigations on natural dyes

    Science.gov (United States)

    Acquaviva, S.; D'Anna, E.; de Giorgi, M. L.; Della Patria, A.; Baraldi, P.

    2010-09-01

    Natural dyes have been used extensively in the past for many purposes, such us to colour fibers and to produce inks, watercolours and paints, but their use declined rapidly after the discovery of synthetic colours. Nowadays we witness a renewed interest, as natural dyes are neither toxic nor polluting. In this work, physical and chemical properties of four selected dyes, namely red (Madder), yellow (Weld and Turmeric) and blue (Woad) colours, produced by means of traditional techniques at the Museo dei Colori Naturali (Lamoli, Italy), have been investigated. The chromatic properties have been studied through the reflectance spectroscopy, a non-invasive technique for the characterisation of chromaticity. Reflection spectra both from powders and egg-yolk tempera models have been acquired to provide the typical features of the dyes in the UV-vis spectral range. Moreover, to assess the feasibility of laser cleaning procedures, tempera layers were investigated after irradiation with an excimer laser. Micro Raman spectroscopy, Scanning Electron Microscopy and Energy Dispersive X-Ray analyses have complemented the survey, returning compositional and morphological information as well. Efforts have been made to give scientific feedback to the production processes and to support the research activity in the restoration of the artworks where these dyes were employed.

  15. Droplet size effects on film drainage between droplet and substrate.

    Science.gov (United States)

    Steinhaus, Benjamin; Spicer, Patrick T; Shen, Amy Q

    2006-06-06

    When a droplet approaches a solid surface, the thin liquid film between the droplet and the surface drains until an instability forms and then ruptures. In this study, we utilize microfluidics to investigate the effects of film thickness on the time to film rupture for water droplets in a flowing continuous phase of silicone oil deposited on solid poly(dimethylsiloxane) (PDMS) surfaces. The water droplets ranged in size from millimeters to micrometers, resulting in estimated values of the film thickness at rupture ranging from 600 nm down to 6 nm. The Stefan-Reynolds equation is used to model film drainage beneath both millimeter- and micrometer-scale droplets. For millimeter-scale droplets, the experimental and analytical film rupture times agree well, whereas large differences are observed for micrometer-scale droplets. We speculate that the differences in the micrometer-scale data result from the increases in the local thin film viscosity due to confinement-induced molecular structure changes in the silicone oil. A modified Stefan-Reynolds equation is used to account for the increased thin film viscosity of the micrometer-scale droplet drainage case.

  16. Hair dye contact allergy

    DEFF Research Database (Denmark)

    Søsted, Heidi; Rastogi, Suresh Chandra; Andersen, Klaus Ejner

    2004-01-01

    Colouring of hair can cause severe allergic contact dermatitis. The most frequently reported hair dye allergens are p-phenylenediamine (PPD) and toluene-2,5-diamine, which are included in, respectively, the patch test standard series and the hairdressers series. The aim of the present study...... was to identify dye precursors and couplers in hair dyeing products causing clinical hair dye dermatitis and to compare the data with the contents of these compounds in a randomly selected set of similar products. The patient material comprised 9 cases of characteristic clinical allergic hair dye reaction, where...... exposure history and patch testing had identified a specific hair dye product as the cause of the reaction. The 9 products used by the patients were subjected to chemical analysis. 8 hair dye products contained toluene-2,5-diamine (0.18 to 0.98%). PPD (0.27%) was found in 1 product, and m-aminophenol (0...

  17. Matrix-assisted laser desorption/ionization mass spectrometric analysis of poly(3,4-ethylenedioxythiophene) in solid-state dye-sensitized solar cells: comparison of in situ photoelectrochemical polymerization in aqueous micellar and organic media.

    Science.gov (United States)

    Zhang, Jinbao; Ellis, Hanna; Yang, Lei; Johansson, Erik M J; Boschloo, Gerrit; Vlachopoulos, Nick; Hagfeldt, Anders; Bergquist, Jonas; Shevchenko, Denys

    2015-04-07

    Solid-state dye-sensitized solar cells (sDSCs) are devoid of such issues as electrolyte evaporation or leakage and electrode corrosion, which are typical for traditional liquid electrolyte-based DSCs. Poly(3,4-ethylenedioxythiophene) (PEDOT) is one of the most popular and efficient p-type conducting polymers that are used in sDSCs as a solid-state hole-transporting material. The most convenient way to deposit this insoluble polymer into the dye-sensitized mesoporous working electrode is in situ photoelectrochemical polymerization. Apparently, the structure and the physicochemical properties of the generated conducting polymer, which determine the photovoltaic performance of the corresponding solar cell, can be significantly affected by the preparation conditions. Therefore, a simple and fast analytical method that can reveal information on polymer chain length, possible chemical modifications, and impurities is strongly required for the rapid development of efficient solar energy-converting devices. In this contribution, we applied matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) for the analysis of PEDOT directly on sDSCs. It was found that the PEDOT generated in aqueous micellar medium possesses relatively shorter polymeric chains than the PEDOT deposited from an organic medium. Furthermore, the micellar electrolyte promotes a transformation of one of the thiophene terminal units to thiophenone. The introduction of a carbonyl group into the PEDOT molecule impedes the growth of the polymer chain and reduces the conductivity of the final polymer film. Both the simplicity of sample preparation (only application of the organic matrix onto the solar cell is needed) and the rapidity of analysis hold the promise of making MALDI MS an essential tool for the physicochemical characterization of conducting polymer-based sDSCs.

  18. Particle Manipulation Methods in Droplet Microfluidics.

    Science.gov (United States)

    Tenje, Maria; Fornell, Anna; Ohlin, Mathias; Nilsson, Johan

    2018-02-06

    This Feature describes the different particle manipulation techniques available in the droplet microfluidics toolbox to handle particles encapsulated inside droplets and to manipulate whole droplets. We address the advantages and disadvantages of the different techniques to guide new users.

  19. Explosive Leidenfrost droplets

    Science.gov (United States)

    Colinet, Pierre; Moreau, Florian; Dorbolo, Stéphane

    2017-11-01

    We show that Leidenfrost droplets made of an aqueous solution of surfactant undergo a violent explosion in a wide range of initial volumes and concentrations. This unexpected behavior turns out to be triggered by the formation of a gel-like shell, followed by a sharp temperature increase. Comparing a simple model of the radial surfactant distribution inside a spherical droplet with experiments allows highlighting the existence of a critical surface concentration for the shell to form. The temperature rise (attributed to boiling point elevation with surface concentration) is a key feature leading to the explosion, instead of the implosion (buckling) scenario reported by other authors. Indeed, under some conditions, this temperature increase is shown to be sufficient to trigger nucleation and growth of vapor bubbles in the highly superheated liquid bulk, stretching the surrounding elastic shell up to its rupture limit. The successive timescales characterizing this explosion sequence are also discussed. Funding sources: F.R.S. - FNRS (ODILE and DITRASOL projects, RD and SRA positions of P. Colinet and S. Dorbolo), BELSPO (IAP 7/38 MicroMAST project).

  20. Phototoxic effect of conjugates of plasmon-resonance nanoparticles with indocyanine green dye on Staphylococcus aureus induced by IR laser radiation

    International Nuclear Information System (INIS)

    Tuchina, E S; Tuchin, Valerii V; Khlebtsov, B N; Khlebtsov, Nikolai G

    2011-01-01

    The effect of IR laser radiation (λ = 805 - 808 nm) on the bacteria of the strain Staphylococcus aureus 209 P, incubated in indocyanine green solutions, is studied, as well as that of colloid gold nanoshells, nanocages and their conjugates with indocyanine green. It is found that the S. aureus 209 P cells are equally subjected to the IR laser radiation (λ = 805 nm) after preliminary sensitisation with indocyanine green and gold nanoparticles separately and with conjugates of nanoparticles and indocyanine green. The enhancement of photodynamic and photothermal effects by 5 % is observed after 30 min of laser illumination (λ = 808 nm) of bacteria, treated with conjugates of indocyanine green and nanocages. (optical technologies in biophysics and medicine)

  1. Droplet size measurement of diesel fuel spray particles using a planar laser-induced fluorescence method; Nijigen laser yuki keikoho wo mochiita diesel funmu ryushi no ryukei keisoku ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, N. [Isuzu Motors Ltd., Tokyo (Japan); Niimura, K. [Nissan Diesel Motor Co. Ltd., Saitama (Japan); Tsujimura, K.

    1997-11-25

    In this study, the planar laser-induced fluorescence (PLIF) technique was used to measure the mean size and size distribution of diesel spray particles. The fuel used was n-tridecane mixed with 1 wt% N, N, Nprime, Nprime-tetramethylparaphenyenediamine (TMPD). The light source used to excite the TMPD in the fuel was a secondary harmonic of a ruby laser-light sheet. A highly magnified image of the fluorescence from TMPD was taken by a 35 mm still camera with magnified optics, and the mean particle size and particle size distribution of the fuel spray were determined by processing the images of fuel particles printed on paper. First, the accuracy of this method was confirmed by comparison with results of Phase Doppler Anemometry for fuel spray of an air-assisted gasoline injector. Then, for the diesel spray, the effects of injection velocity, ambient pressure, geometric configuration of nozzle hole (i.e., nozzle hole diameter and nozzle hole L/D) and of measurement points on the fuel particle mean size and size distribution in a high-pressure vessel at atmospheric temperature were investigated. The results showed that the small size particles increase in number with increasing injection velocity. At higher injection velocity, seem to atomize more actively. With increasing ambient pressure, the mean particle size increases. A reduction in nozzle diameter resulted in no improvement of atomization in this study. Also, the mean particle size in the downstream region of the spray is larger than that in the upstream region of the spray. 16 refs., 19 figs., 3 tabs.

  2. Millifluidic droplet analyser for microbiology

    NARCIS (Netherlands)

    Baraban, L.; Bertholle, F.; Salverda, M.L.M.; Bremond, N.; Panizza, P.; Baudry, J.; Visser, de J.A.G.M.; Bibette, J.

    2011-01-01

    We present a novel millifluidic droplet analyser (MDA) for precisely monitoring the dynamics of microbial populations over multiple generations in numerous (=103) aqueous emulsion droplets (100 nL). As a first application, we measure the growth rate of a bacterial strain and determine the minimal

  3. Sampling system for pulsed signals. Study of the radioactive lifetimes of excited 3{sup 2}P1/2 and 3{sup 2}P3/2 states of Na, excited by a tunable dye laser; Sistema de muestreo para senales pulsadas. Estudio de vidas medias de niveles 3{sup 2} P1/2 y 3{sup 2}P3/2 excitados por un laser de colorantes pulsado

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, P; Campos, J

    1979-07-01

    A system for sampling and averaging repetitive signals in the order of nanoseconds is discussed. The system uses as storage memory a multichannel analyzer operating in multi scaling mode. This instrument is employed for the measurement of atomic level lifetimes using a dye laser to excite the atoms and is applied to the study of lifetimes of the 3{sup 2}P1/2 and 3{sup 2}P3/2 states of sodium. (Author) 32 refs.

  4. Leidenfrost boiling of water droplet

    Directory of Open Access Journals (Sweden)

    Orzechowski Tadeusz

    2017-01-01

    Full Text Available The investigations concerned a large water droplet at the heating surface temperature above the Leidenfrost point. The heating cylinder was the main component of experimental stand on which investigations were performed. The measurement system was placed on the high-sensitivity scales. Data transmission was performed through RS232 interface. The author-designed program, with extended functions to control the system, was applied. The present paper examines the behaviour of a large single drop levitating over a hot surface, unsteady mass of the drop, and heat transfer. In computations, the dependence, available in the literature, for the orthogonal droplet projection on the heating surface as a function of time was employed. It was confirmed that the local value of the heat transfer coefficient is a power function of the area of the droplet surface projection. Also, a linear relationship between the flux of mass evaporated from the droplet and the droplet orthogonal projection was observed.

  5. Leidenfrost boiling of water droplet

    Science.gov (United States)

    Orzechowski, Tadeusz

    The investigations concerned a large water droplet at the heating surface temperature above the Leidenfrost point. The heating cylinder was the main component of experimental stand on which investigations were performed. The measurement system was placed on the high-sensitivity scales. Data transmission was performed through RS232 interface. The author-designed program, with extended functions to control the system, was applied. The present paper examines the behaviour of a large single drop levitating over a hot surface, unsteady mass of the drop, and heat transfer. In computations, the dependence, available in the literature, for the orthogonal droplet projection on the heating surface as a function of time was employed. It was confirmed that the local value of the heat transfer coefficient is a power function of the area of the droplet surface projection. Also, a linear relationship between the flux of mass evaporated from the droplet and the droplet orthogonal projection was observed.

  6. Liquid droplet radiator technology issues

    International Nuclear Information System (INIS)

    Mattick, A.T.; Hertzberg, A.

    1985-01-01

    The operation of the liquid droplet radiator (LDR) is analyzed to establish design constraints for the LDR components and to predict the performance of an integrated LDR system. The design constraints largely result from mass loss considerations: fluid choice is governed by evaporation loss; droplet generation techniques must be capable of precise aiming of >10 5 droplet streams; and collection losses must be less than 1 droplet in 10 7 . Concepts for droplet generation and collection components are discussed and incorporated into a mass model for an LDR system. This model predicts that LDR's using lithium, Dow 705 silicone fluid, or NaK may be several times lighter than heat pipe radiators. 13 refs

  7. Measuring stable isotopes of hydrogen and oxygen in ice by means of laser spectrometry : The Bolling transition in the Dye-3 (south Greenland) ice core

    NARCIS (Netherlands)

    Trigt, R. van; Meijer, H.A.J.; Sveinbjornsdottir, A.E.; Johnsen, S.J.; Kerstel, E.R.Th.

    2002-01-01

    We report on the first application of a new technique in ice-core research, based on direct absorption infrared laser spectrometry (LS), for measuring H-2 O-17 and O-18 isotope ratios. The data are used to calculate the deuterium excess d (defined as delta(2)H - 8delta(18)O) for a section of the

  8. Droplet activation, separation, and compositional analysis: laboratory studies and atmospheric measurements

    Science.gov (United States)

    Hiranuma, N.; Kohn, M.; Pekour, M. S.; Nelson, D. A.; Shilling, J. E.; Cziczo, D. J.

    2011-10-01

    Droplets produced in a cloud condensation nuclei chamber (CCNC) as a function of supersaturation have been separated from unactivated aerosol particles using counterflow virtual impaction. Residual material after droplets were evaporated was chemically analyzed with an Aerodyne Aerosol Mass Spectrometer (AMS) and the Particle Analysis by Laser Mass Spectrometry (PALMS) instrument. Experiments were initially conducted to verify activation conditions for monodisperse ammonium sulfate particles and to determine the resulting droplet size distribution as a function of supersaturation. Based on the observed droplet size, the counterflow virtual impactor cut-size was set to differentiate droplets from unactivated interstitial particles. Validation experiments were then performed to verify that only droplets with sufficient size passed through the counterflow virtual impactor for subsequent analysis. A two-component external mixture of monodisperse particles was also exposed to a supersaturation which would activate one of the types (hygroscopic salts) but not the other (polystyrene latex spheres or adipic acid). The mass spectrum observed after separation indicated only the former, validating separation of droplets from unactivated particles. Results from ambient measurements using this technique and AMS analysis were inconclusive, showing little chemical differentiation between ambient aerosol and activated droplet residuals, largely due to low signal levels. When employing as single particle mass spectrometer for compositional analysis, however, we observed enhancement of sulfate in droplet residuals.

  9. Lossless droplet transfer of droplet-based microfluidic analysis

    Science.gov (United States)

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Page, Jason S [Kennewick, WA; Smith, Richard D [Richland, WA

    2011-11-22

    A transfer structure for droplet-based microfluidic analysis is characterized by a first conduit containing a first stream having at least one immiscible droplet of aqueous material and a second conduit containing a second stream comprising an aqueous fluid. The interface between the first conduit and the second conduit can define a plurality of apertures, wherein the apertures are sized to prevent exchange of the first and second streams between conduits while allowing lossless transfer of droplets from the first conduit to the second conduit through contact between the first and second streams.

  10. Study and realisation of a femtosecond dye laser operating at different wavelengths. Ultrashort pulses compression and amplification; Etude et realisation d'un laser a colorant femtoseconde fonctionnant a differentes longueurs d'onde. Compression et amplification d'impulsions ultrabreves

    Energy Technology Data Exchange (ETDEWEB)

    Georges, Patrick

    1989-12-21

    We present the study and the realization of a passively mode-locked dye laser producing pulses shorter than 100 femto-seconds (10{sup -13} s). In a ring cavity with an amplifier medium (Rhodamine 60) and a saturable absorber (DODCI), a sequence of four prisms controls the group velocity dispersion and allows the generation of very short pulses. Then we have studied the production of femtosecond pulses at other wavelengths directly from the femtosecond dye laser. For the first rime, 60 fs pulses at 685 nm and pulses shorter than 50 fs between 775 nm and 800 nm have been produced by passive mode locking. These near infrared pulses have been used to study the absorption saturation kinetics in semiconductors multiple quantum wells GaAs/GaAlAs. We have observed a singular behavior of the laser operating at 685 nm and analyzed the produced pulses in terms of optical solitons. To perform time resolved spectroscopy with shortest pulses, we have studied a pulse compressor and a multipass amplifier to increase the pulses energy. Pulses of 20 fs and 10 micro-joules (peak power: 0.5 GW) have been obtained at low repetition rate (10 Hz) and pulses of 16 fs and 0.6 micro-joules pulses have been generated at high repetition rate (11 kHz) using a copper vapor laser. These pulses have been used to study the absorption saturation kinetics of an organic dye (the Malachite Green). (author) [French] Ce memoire presente l'etude et la realisation d'un laser a colorant a verrouillage de modes passif produisant des impulsions de 100 femtosecondes (10- 13 s). Dans une cavite en anneau contenant un milieu amplificateur (Rhodamine 60) et un absorbant saturable (DODCI), un systeme de prismes permettant de controler la dispersion de vitesse de groupe realise une mise en phase de toutes les frequences du spectre des impulsions. Nous avons ensuite etudie la possibilite de produire des impulsions femtosecondes a d'autres longueurs d'onde directement avec l'oscillateur. Des impulsions de 60 fs a

  11. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  12. Hyper-Rayleigh scattering and hyper-Raman scattering of dye-adsorbed silver nanoparticles induced by a focused continuous-wave near-infrared laser

    International Nuclear Information System (INIS)

    Itoh, Tamitake; Ozaki, Yukihiro; Yoshikawa, Hiroyuki; Ihama, Takashi; Masuhara, Hiroshi

    2006-01-01

    We report that hyper-Rayleigh scattering, surface-enhanced hyper-Raman scattering, and two-photon excited luminescence occur intermittently by focusing a continuous-wave near-infrared (cw-NIR) laser into a colloidal silver solution including rhodamine 6G (R6G) and sodium chloride (NaCl). On the other hand, continuous hyper-Rayleigh scattering is observed from colloidal silver free from R6G and NaCl, demonstrating that hyper-Raman scattering and two-photon excited luminescence are attributed to R6G and their intermittent features are dependent on the colloidal dispersion. These results suggest that the cw-NIR laser has three roles; the source of the nonlinear response, optical trapping of nanoparticles, and making nanoparticle aggregates possessing the high activity for the nonlinear response

  13. Lasing ability of naphthyl 1, 3, 4, oxadiazole molecules in relation with their structures: application to the design of new UV dye laser

    Energy Technology Data Exchange (ETDEWEB)

    Rulliere, C; Rayez, J C [Bordeaux-1 Univ., 33 - Talence (France). Lab. de Chimie Physique A

    1976-11-01

    The lasing properties of naphtyl 1,3,4 oxadiazole derivatives were found to be directly related to the position of the forbidden transition S/sub 0/ ..-->../sup 1/Lsub(b) of naphtalene with respect to the first allowed transitions. The combination of theoretical and experimental results allows us to predict which compounds are most likely to exhibit a laser effect according to the nature and the position of their substituants. This approach was successfully applied to the following compounds: ..cap alpha..NPD, ..beta..NPD, ..cap alpha..NND, ..beta..NND, ..beta..NBD, and ..cap alpha..NBD. In particular we reported the first observation of a laser effect for ..cap alpha..NBD and ..beta..NBD in the UV at 3830 A and 3758 A is reported.

  14. Droplet spectrum of a spray nozzle under different weather conditions

    Directory of Open Access Journals (Sweden)

    Christiam Felipe Silva Maciel

    Full Text Available ABSTRACT The application of pesticides is always susceptible to losses through evaporation and drift of the spray droplets. With these losses, a smaller amount of pesticide reaches the target, possibly impairing the efficiency of phytosanitary control. Due to these concerns, the aim of this study was to evaluate the interference of weather conditions in the droplet spectrum produced by hydraulic spraying. To carry out the work, it was necessary to build an experimental system. This consisted of a laser particle-size analyser, hydraulic nozzle (Jacto JSF 11002, stationary sprayer, gas heater, wind tunnel, climate chamber (with the aim of maintaining the internal psychrometry similar to that of the air exiting the wind tunnel, collector, and temperature and RH sensors. The weather conditions for the study included vapour pressure deficits (VPD of 5, 9.4, 20, 30.6 and 35 hPa, and air velocities of 2, 3.6, 7.4, 11.2 and 12.8 km h-1. A Rotatable Central Composite Design was used, and the data related using Response Surface Methodology. The wind caused such a sharp drift in the fine droplets, that it greatly affected the behaviour of the entire droplet spectrum, as well as hiding the effect of the VPD. However, the conclusion is that drift and evaporation both act on the coarser droplets.

  15. Photoacoustic measurements of photokinetics in single optically trapped aerosol droplets

    Science.gov (United States)

    Covert, Paul; Cremer, Johannes; Signorell, Ruth; Thaler, Klemens; Haisch, Christoph

    2017-04-01

    It is well established that interaction of light with atmospheric aerosols has a large impact on the Earth's climate. However, uncertainties in the magnitude of this impact remain large, due in part to broad distributions of aerosol size, composition, and chemical reactivity. In this context, photoacoustic spectroscopy is commonly used to measure light absorption by aerosols. Here, we present photoacoustic measurements of single, optically-trapped nanodroplets to reveal droplet size-depencies of photochemical and physical processes. Theoretical considerations have pointed to a size-dependence in the magnitude and phase of the photoacoustic response from aerosol droplets. This dependence is thought to originate from heat transfer processes that are slow compared to the acoustic excitation frequency. In the case of a model aerosol, our measurements of single particle absorption cross-section versus droplet size confirm these theoretical predictions. In a related study, using the same model aerosol, we also demonstrate a droplet size-dependence of photochemical reaction rates [1]. Within sub-micron sized particles, photolysis rates were observed to be an order of magnitude greater than those observed in larger droplets. [1] J. W. Cremer, K. M. Thaler, C. Haisch, and R. Signorell. Photoacoustics of single laser-trapped nanodroplets for the direct observation of nanofocusing in aerosol photokinetics. Nat. Commun., 7:10941, 2016.

  16. Lasers for the SILVA laser isotope separation process

    International Nuclear Information System (INIS)

    Lapierre, Y.

    1997-01-01

    The main principles of the laser isotope separation process for the production of enriched uranium at lower cost, are reviewed and the corresponding optimal laser characteristics are described. The development of the SILVA laser isotope separation process involved researches in the various domains of pump lasers, dye lasers, laser and optics systems and two test facilities for the feasibility studies which are expected for 1997

  17. WATERLESS DYEING [REVIEW

    Directory of Open Access Journals (Sweden)

    DEVRENT Nalan

    2015-05-01

    Full Text Available The textile industry is believed to be one of the biggest consumers of water. Water consumption and exhaustion in dyeing textile materials in conventional methods is an important environmental problem. The cost of waste water treatment will cause a prominent problem in the future as it does today. Increasing consideration of ecologic consequences of industrial processes as well as legislation enforcing the avoidance of environmental problems have caused a reorientation of thinking and promoted projects for replacement of conventional technologies. One of these new technologies is dyeing in supercritical fluids. Dyeing with supercritical carbon dioxide is a favourable concept considering the value of water as a natural resource and the cost of waste water treatment. This dyeing method offers many advantages over conventional aqueous dyeing: During this dyeing process no water is used, therefore there is no waste water problem, no other chemicals are required; the carbon dioxide can be recycled; the dystuff which is not adsorbed on the substrate can be collected and reused; The necessary energy consumption in this process is relatively lower than is needed to heat water in conventional methods of dyeing. Due to unnecessary of drying process, it helps to save both energy and time; and dyeing cycle is shorter compared with traditional methods. In addition carbon dioxide is non-toxic and non-flammable. Supercritical fluid, supercritical dyeing, disperse dyestuffs, solid-fluid equilibrium

  18. Histochemical study of trans-polyisoprene accumulation by spectral confocal laser scanning microscopy and a specific dye showing fluorescence solvatochromism in the rubber-producing plant, Eucommia ulmoides Oliver.

    Science.gov (United States)

    Nakazawa, Yoshihisa; Takeda, Tsuyoshi; Suzuki, Nobuaki; Hayashi, Tatsushi; Harada, Yoko; Bamba, Takeshi; Kobayashi, Akio

    2013-09-01

    A microscopic technique combining spectral confocal laser scanning microscopy with a lipophilic fluorescent dye, Nile red, which can emit trans-polyisoprene specific fluorescence, was developed, and unmixed images of synthesized trans-polyisoprene in situ in Eucommia ulmoides were successfully obtained. The images showed that trans-polyisoprene was initially synthesized as granules in non-articulated laticifers that changed shape to fibers during laticifer maturation. Non-articulated laticifers are developed from single laticiferous cells, which are differentiated from surrounding parenchyma cells in the cambium. Therefore, these observations suggested that trans-polyisoprene biosynthesis first started in laticifer cells as granules and then the granules accumulated and fused in the inner space of the laticifers over time. Finally, laticifers were filled with the synthesized trans-polyisoprene, which formed a fibrous structure fitting the laticifers shape. Both trans- and cis-polyisoprene are among the most important polymers naturally produced by plants, and this microscopic technique combined with histological study should provide useful information in the fields of plant histology, bioindustry and phytochemistry.

  19. The dynamics of milk droplet-droplet collisions

    Science.gov (United States)

    Finotello, Giulia; Kooiman, Roeland F.; Padding, Johan T.; Buist, Kay A.; Jongsma, Alfred; Innings, Fredrik; Kuipers, J. A. M.

    2018-01-01

    Spray drying is an important industrial process to produce powdered milk, in which concentrated milk is atomized into small droplets and dried with hot gas. The characteristics of the produced milk powder are largely affected by agglomeration, combination of dry and partially dry particles, which in turn depends on the outcome of a collision between droplets. The high total solids (TS) content and the presence of milk proteins cause a relatively high viscosity of the fed milk concentrates, which is expected to largely influence the collision outcomes of drops inside the spray. It is therefore of paramount importance to predict and control the outcomes of binary droplet collisions. Only a few studies report on droplet collisions of high viscous liquids and no work is available on droplet collisions of milk concentrates. The current study therefore aims to obtain insight into the effect of viscosity on the outcome of binary collisions between droplets of milk concentrates. To cover a wide range of viscosity values, three milk concentrates (20, 30 and 46% TS content) are investigated. An experimental set-up is used to generate two colliding droplet streams with consistent droplet size and spacing. A high-speed camera is used to record the trajectories of the droplets. The recordings are processed by Droplet Image Analysis in MATLAB to determine the relative velocities and the impact geometries for each individual collision. The collision outcomes are presented in a regime map dependent on the dimensionless impact parameter and Weber ( We) number. The Ohnesorge ( Oh) number is introduced to describe the effect of viscosity from one liquid to another and is maintained constant for each regime map by using a constant droplet diameter ( d ˜ 700 μ m). In this work, a phenomenological model is proposed to describe the boundaries demarcating the coalescence-separation regimes. The collision dynamics and outcome of milk concentrates are compared with aqueous glycerol

  20. Resonance Raman and UV-visible spectroscopy of black dyes on textiles.

    Science.gov (United States)

    Abbott, Laurence C; Batchelor, Stephen N; Smith, John R Lindsay; Moore, John N

    2010-10-10

    Resonance Raman and UV-visible diffuse reflectance spectra were recorded from samples of cotton, viscose, polyester, nylon, and acrylic textile swatches dyed black with one of seven single dyes, a mixture of two dyes, or one of seven mixtures of three dyes. The samples generally gave characteristic Raman spectra of the dyes, demonstrating that the technique is applicable for the forensic analysis of dyed black textiles. Survey studies of the widely used dye Reactive Black 5 show that essentially the same Raman spectrum is obtained on bulk sampling from the dye in solution, on viscose, on cotton at different uptakes, and on microscope sampling from the dye in cotton threads and single fibres. The effects of laser irradiation on the Raman bands and emission backgrounds from textile samples with and without dye are also reported. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Electrohydrodynamic simulation of electrically controlled droplet generation

    International Nuclear Information System (INIS)

    Ouedraogo, Yun; Gjonaj, Erion; Weiland, Thomas; Gersem, Herbert De; Steinhausen, Christoph; Lamanna, Grazia; Weigand, Bernhard

    2017-01-01

    Highlights: • We develop a full electrohydrodynamic simulation approach which allows for the accurate modeling of droplet dynamics under the influence of transient electric fields. The model takes into account conductive, capacitive as well as convective electrical currents in the fluid. • Simulation results are shown for an electrically driven droplet generator using highly conductive acetone droplets and low conductivity pentane droplets, respectively. Excellent agreement with measurement is found. • We investigate the operation characteristic of the droplet generator by computing droplet sizes and detachment times with respect to the applied voltage. • The droplet charging effect is demonstrated for pentane droplets as well as for acetone droplets under long voltage pulses. We show that due to the very different relaxation times, the charging behavior of the two liquids is very different. • We demonstrate that due to this behavior, also the detachment mechanisms for acetone and pentane droplets are different. For low conductivity (pentane) droplets, droplet detachment is only possible after the electric fields are switched off. This is because the effective electric polarization force points upwards, thus, inhibiting the detachment of the droplet from the capillary tip. - Abstract: An electrohydrodynamic model for the simulation of droplet formation, detachment and motion in an electrically driven droplet generator is introduced. The numerical approach is based on the coupled solution of the multiphase flow problem with the charge continuity equation. For the latter, a modified convection-conduction model is applied, taking into account conductive, capacitive as well as convective electrical currents in the fluid. This allows for a proper description of charge relaxation phenomena in the moving fluid. In particular, the charge received by the droplet after detachment is an important parameter influencing the droplet dynamics in the test chamber

  2. Pulsed dye laser vs. intense pulsed light for port-wine stains: a randomized side-by-side trial with blinded response evaluation

    DEFF Research Database (Denmark)

    Faurschou, A; Togsverd-Bo, K; Zachariae, C

    2009-01-01

    Corporation, Wayland, MA, U.S.A.) and IPL (StarLux, Lux G prototype handpiece, 500-670 and 870-1400 nm, 5-10 ms; Palomar Medical Technologies, Burlington, MA, U.S.A.). Settings depended on the preoperative lesional colour. Treatment outcome was evaluated by blinded, clinical evaluations and by skin......: To compare efficacy and adverse events of PDL and IPL in an intraindividual randomized clinical trial. METHODS: Twenty patients with PWS (face, trunk, extremities; pink, red and purple colours; skin types I-III) received one side-by-side treatment with PDL (V-beam Perfecta, 595 nm, 0.45-1.5 ms; Candela Laser...

  3. Oleoplaning droplets on lubricated surfaces

    Science.gov (United States)

    Daniel, Dan; Timonen, Jaakko V. I.; Li, Ruoping; Velling, Seneca J.; Aizenberg, Joanna

    2017-10-01

    Recently, there has been much interest in using lubricated surfaces to achieve extreme liquid repellency: a foreign droplet immiscible with the underlying lubricant layer was shown to slide off at a small tilt angle behaviour was hypothesized to arise from a thin lubricant overlayer film sandwiched between the droplet and solid substrate, but this has not been observed experimentally. Here, using thin-film interference, we are able to visualize the intercalated film under both static and dynamic conditions. We further demonstrate that for a moving droplet, the film thickness follows the Landau-Levich-Derjaguin law. The droplet is therefore oleoplaning--akin to tyres hydroplaning on a wet road--with minimal dissipative force and no contact line pinning. The techniques and insights presented in this study will inform future work on the fundamentals of wetting for lubricated surfaces and enable their rational design.

  4. Droplet Translation Actuated by Photoelectrowetting.

    Science.gov (United States)

    Palma, Cesar; Deegan, Robert D

    2018-03-13

    In traditional electrowetting-on-dielectric (EWOD) devices, droplets are moved about a substrate using electric fields produced by an array of discrete electrodes. In this study, we show that a drop can be driven across a substrate with a localized light beam by exploiting the photoelectrowetting (PEW) effect, a light-activated variant of EWOD. Droplet transport actuated by PEW eliminates the need for electrode arrays and the complexities entailed in their fabrication and control, and offers a new approach for designing lab-on-a-chip applications. We report measurements of the maximum droplet speed as a function of frequency and magnitude of the applied bias, intensity of illumination, volume of the droplet, and viscosity and also introduce a model that reproduces these data.

  5. Quantum Nanostructures by Droplet Epitaxy

    OpenAIRE

    Somsak Panyakeow

    2009-01-01

    Droplet epitaxy is an alternative growth technique for several quantum nanostructures. Indium droplets are distributed randomly on GaAs substrates at low temperatures (120-350'C). Under background pressure of group V elements, Arsenic and Phosphorous, InAs and InP nanostructures are created. Quantum rings with isotropic shape are obtained at low temperature range. When the growth thickness is increased, quantum rings are transformed to quantum dot rings. At high temperature range, anisotropic...

  6. Anaerobic azo dye reduction

    NARCIS (Netherlands)

    Zee, van der F.P.

    2002-01-01

    Azo dyes, aromatic moieties linked together by azo (-N=N-) chromophores, represent the largest class of dyes used in textile-processing and other industries. The release of these compounds into the environment is undesirable, not only because of their colour, but also

  7. Extraction of dye

    African Journals Online (AJOL)

    Dyes of natural origins are great for color appreciation as any variation in the concentration of dye, mordant, type of water, soil and climate give variations in ... Grey scale and blue dyed silk were used for color fastness rating. ..... Down to Earth.

  8. Tunable on chip optofluidic laser

    DEFF Research Database (Denmark)

    Bakal, Avraham; Vannahme, Christoph; Kristensen, Anders

    2016-01-01

    On chip tunable laser is demonstrated by realizing a microfluidic droplet array. The periodicity is controlled by the pressure applied to two separate inlets, allowing to tune the lasing frequency over a broad spectral range.......On chip tunable laser is demonstrated by realizing a microfluidic droplet array. The periodicity is controlled by the pressure applied to two separate inlets, allowing to tune the lasing frequency over a broad spectral range....

  9. LDA measurement of droplet behavior across tie plate during dispersed flow portion of loca reflood

    International Nuclear Information System (INIS)

    Lee, S.L.; Srinivasan, J.; Cho, S.K.

    1980-01-01

    The flow of an air-water droplet dispersion in a simulated 3-D test section in the reflood portion of LOCA was studied. For this purpose, a new scheme of Laser-Doppler Anemometry for the simultaneous measurement of size and velocity of large-size [0.5 mm-6 mm] droplets was developed and utilized. It was observed that the size distribution of the reentrained droplets depends mainly on the flow regimes and is essentially independent of that of the incoming dispersion below the tie plate. 8 refs

  10. PVA with nopal dye as holographic recording material

    Science.gov (United States)

    Toxqui-López, S.; Olivares-Pérez, A.; Fuentes-Tapia, I.; Pinto-Iguanero, B.

    2011-09-01

    Cactus nopal dye is introduced into a polyvinyl alcohol matrix achieving a like brown appearance thick film, such that they can be used as a recording medium. This dye material provides excellent property as photosensitizer, i.e., easy handling, low cost and can be used in real time holographic recording applications. The experimental results show the diffraction efficiencies obtained by recording grating patterns induced by a He-Cd laser (442nm). For the samples, a thick film of polyvinyl alcohol and dye from cactus nopal was deposited by the gravity technique on a glass substrate. This mixture dries to form a photosensitive emulsion.

  11. Laser plasma LINAC

    International Nuclear Information System (INIS)

    Palmer, R.B.; Baggett, N.; Claus, J.; Fernow, R.; Ghosh, A.; Giordano, S.; Radeka, V.; Stumer, I.; Takacs, P.; Warren, J.

    1985-01-01

    The grating accelerator concept is reviewed. The use of a double row of conducting droplets instead of a conventional grating constrains the fields to a narrow band. The use of droplets also allows fields that will destroy the structure. RF modelling results are presented together with a simple theory of the fields. Coupling to incoming radiation is described. A possible laser specification is also given. (orig.)

  12. Laser plasma LINAC

    International Nuclear Information System (INIS)

    Palmer, R.B.; Baggett, N.; Claus, J.

    1984-01-01

    The grating accelerator concept is reviewed. The use of a double row of conducting droplets instead of a conventional grating constrains the fields to a narrow band. The use of droplets also allows fields that will destroy the structure. The rf modeling results are presented together with a simple theory of the fields. Coupling to incoming radiation is described. A possible laser specification is also given. 9 references, 8 figures

  13. Development of advanced diagnostics for characterization of burning droplets in microgravity

    Science.gov (United States)

    Sankar, Subramanian; Buermann, Dale H.; Bachalo, William D.

    1995-01-01

    Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel

  14. Evaluation of StereoPIV Measurement of Droplet Velocity in an Effervescent Spray

    Directory of Open Access Journals (Sweden)

    Sina Ghaemi

    2010-06-01

    Full Text Available Particle image velocimetry (PIV is a well known technique for measuring the instantaneous velocity field of flows. However, error may be introduced when measuring the velocity field of sprays using this technique when the spray droplets are used as the seed particles. In this study, the effect of droplet number density, droplet velocity profile, and droplet size distribution of a spray produced by an effervescent atomizer on velocity measurement using a StereoPIV has been investigated. A shadowgraph-particle tracking velocimetry (S-PTV system provided measurement of droplet size and velocity for comparison. This investigation demonstrated that the StereoPIV under-estimates velocity at near-field dense spray region where measurement accuracy is limited by multi-scattering of the laser sheet. In the dilute far-field region of the spray, StereoPIV measurement is mostly in agreement with velocity of the droplet size-class which is close to the mean diameter based on droplet number frequency times droplet cross sectional area.

  15. In situ droplet size and speed determination in a fluid-bed granulator.

    Science.gov (United States)

    Ehlers, Henrik; Larjo, Jussi; Antikainen, Osmo; Räikkönen, Heikki; Heinämäki, Jyrki; Yliruusi, Jouko

    2010-05-31

    The droplet size affects the final product in fluid-bed granulation and coating. In the present study, spray characteristics of aqueous granulation liquid (purified water) were determined in situ in a fluid-bed granulator. Droplets were produced by a pneumatic nozzle. Diode laser stroboscopy (DLS) was used for droplet detection and particle tracking velocimetry (PTV) was used for determination of droplet size and speed. Increased atomization pressure decreased the droplet size and the effect was most strongly visible in the 90% size fractile. The droplets seemed to undergo coalescence after which only slight evaporation occurred. Furthermore, the droplets were subjected to a strong turbulence at the event of atomization, after which the turbulence reached a minimum value in the lower halve of the chamber. The turbulence increased as speed and droplet size decreased due to the effects of the fluidizing air. The DLS and PTV system used was found to be a useful and rapid tool in determining spray characteristics and in monitoring and predicting nozzle performance. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  16. Uniform-droplet spray forming

    Energy Technology Data Exchange (ETDEWEB)

    Blue, C.A.; Sikka, V.K. [Oak Ridge National Lab., TN (United States); Chun, Jung-Hoon [Massachusetts Institute of Technology, Cambridge, MA (United States); Ando, T. [Tufts Univ., Medford, MA (United States)

    1997-04-01

    The uniform-droplet process is a new method of liquid-metal atomization that results in single droplets that can be used to produce mono-size powders or sprayed-on to substrates to produce near-net shapes with tailored microstructure. The mono-sized powder-production capability of the uniform-droplet process also has the potential of permitting engineered powder blends to produce components of controlled porosity. Metal and alloy powders are commercially produced by at least three different methods: gas atomization, water atomization, and rotating disk. All three methods produce powders of a broad range in size with a very small yield of fine powders with single-sized droplets that can be used to produce mono-size powders or sprayed-on substrates to produce near-net shapes with tailored microstructures. The economical analysis has shown the process to have the potential of reducing capital cost by 50% and operating cost by 37.5% when applied to powder making. For the spray-forming process, a 25% savings is expected in both the capital and operating costs. The project is jointly carried out at Massachusetts Institute of Technology (MIT), Tuffs University, and Oak Ridge National Laboratory (ORNL). Preliminary interactions with both finished parts and powder producers have shown a strong interest in the uniform-droplet process. Systematic studies are being conducted to optimize the process parameters, understand the solidification of droplets and spray deposits, and develop a uniform-droplet-system (UDS) apparatus appropriate for processing engineering alloys.

  17. Intermolecular energy transfer in binary systems of dye polymers

    Science.gov (United States)

    Liu, Lin-I.; Barashkov, Nikolay N.; Palsule, Chintamani P.; Gangopadhyay, Shubhra; Borst, Walter L.

    2000-10-01

    We present results and physical interpretations for the energy transfer mechanisms in two-component dye polymer systems. The data consist of fluorescence emission spectra and decays. Two dyes were embedded in an epoxypolymer base, and only they participated in the energy transfer. Following pulsed laser excitation of the donor dye, energy transfer took place to the accept dye. The possible transfer paths considered here were nonradiative and radiative transfer. The latter involves two steps, emission and absorption of a photon, and therefore is relatively slow, while nonradiative transfer is a fast single step resulting from direct Coulomb interactions. A predominantly nonradiative transfer is desirable for applications, for instance in wavelength shifters in high energy particle detection. We studied the concentration effects of the dyes on the energy transfer and obtained the relative quantum efficiencies of various wavelength shifters from the fluorescence emission spectra. For low acceptor concentrations, radiative transfer was found to dominate, while nonradiative transfer became dominant at increasing dye concentrations. The fluorescence decays were analyzed with a sum-of-exponentials method and with Förster kinetics. The sum of exponential model yielded mean decay times of the dye polymers useful for a general classification. The decay times decreased as desired with increasing acceptor concentration. The samples, in which nonradiative energy transfer dominated, were analyzed with Förster kinetics. As a result, the natural decay times of the donor and acceptor dyes and the critical radii for nonradiative energy transfer were obtained from a global best fit.

  18. Direct thermal dyes

    Science.gov (United States)

    Ehlinger, Edward

    1990-07-01

    Direct thermal dyes are members of a class of compounds referred to in the imaging industry as color formers or leuco dyes. The oldest members of that class have simple triarylmethane structures, and have been employed for years in various dyeing applications. More complex triarylmethane compounds, such as phthalides and fluorans, are now used in various imaging systems to produce color. Color is derived from all of these compounds via the same mechanism, on a molecular level. That is, an event of activation produces a highly resonating cationic system whose interaction with incident light produces reflected light of a specific color. The activation event in the case of a direct thermal system is the creation of a melt on the paper involving dye and an acidic developer. The three major performance parameters in a thermal system are background color, image density, and image stability. The three major dye physical parameters affecting thermal performance are chemical constituency, purity, and particle size. Those dyes having the best combination of characteristics which can also be manufactured economically dominate the marketplace. Manufacturing high performance dyes for the thermal market involves multi-step, convergent reaction sequences performed on large scale. Intermediates must be manufactured at the right time, and at the right quality to be useful.

  19. Dyes for displays

    Science.gov (United States)

    Claussen, U.

    1984-01-01

    The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.

  20. Dyeing of Polyester with Disperse Dyes: Part 2. Synthesis and Dyeing Characteristics of Some Azo Disperse Dyes for Polyester Fabrics

    Directory of Open Access Journals (Sweden)

    Alya M. Al-Etaibi

    2016-06-01

    Full Text Available The goal of this study was to utilize carrier for accelerating the rate of dyeing not only to enhance dyeing of polyester fabrics dyed with disperse dyes 3a,b, but also to save energy. Both the color strength expressed as dye uptake and the fastness properties of the dyed fabrics were evaluated.

  1. Excimer laser applications

    International Nuclear Information System (INIS)

    Fantoni, R.

    1988-01-01

    This lecture deals with laser induced material photoprocessing, especially concerning those processes which are initiated by u.v. lasers (mostly excimer laser). Advantages of using the u.v. radiation emitted by excimer lasers, both in photophysical and photochemical processes of different materials, are discussed in detail. Applications concerning microelectronics are stressed with respect to other applications in different fields (organic chemistry, medicine). As further applications of excimer lasers, main spectroscopic techniques for ''on line'' diagnostics which employ excimer pumped dye lasers, emitting tunable radiation in the visible and near u.v. are reviewed

  2. Instability of expanding bacterial droplets.

    Science.gov (United States)

    Sokolov, Andrey; Rubio, Leonardo Dominguez; Brady, John F; Aranson, Igor S

    2018-04-03

    Suspensions of motile bacteria or synthetic microswimmers, termed active matter, manifest a remarkable propensity for self-organization, and formation of large-scale coherent structures. Most active matter research deals with almost homogeneous in space systems and little is known about the dynamics of strongly heterogeneous active matter. Here we report on experimental and theoretical studies on the expansion of highly concentrated bacterial droplets into an ambient bacteria-free fluid. The droplet is formed beneath a rapidly rotating solid macroscopic particle inserted in the suspension. We observe vigorous instability of the droplet reminiscent of a violent explosion. The phenomenon is explained in terms of continuum first-principle theory based on the swim pressure concept. Our findings provide insights into the dynamics of active matter with strong density gradients and significantly expand the scope of experimental and analytic tools for control and manipulation of active systems.

  3. The Effect of pH and High-Pressure Homogenization on Droplet Size

    Directory of Open Access Journals (Sweden)

    Ah Pis Yong

    2017-12-01

    Full Text Available The aims of this study are to revisit the effect of high pressure on homogenization and the influence of pH on the emulsion droplet sizes. The high-pressure homogenization (HPH involves two stages of processing, where the first stage involves in blending the coarse emulsion by a blender, and the second stage requires disruption of the coarse emulsion into smaller droplets by a high-pressure homogenizer. The pressure range in this review is in between 10-500 MPa. The homogenised droplet sizes can be reduced by increasing the homogenization recirculation, and there is a threshold point beyond that by applying pressure only, the size cannot be further reduced. Normally, homogenised emulsions are classified by their degree of kinetic stability. Dispersed phase present in the form of droplets while continuous phase also known as suspended droplets. With a proper homogenization recirculation and pressure, a more kinetically stable emulsion can be produced. The side effects of increasing homogenization pressure are that it can cause overprocessing of the emulsion droplets where the droplet sizes become larger rather than the expected smaller size. This can cause kinetic instability in the emulsion. The droplet size is usually measured by dynamic light scattering or by laser light scattering technique. The type of samples used in this reviews are such as chocolate and vanilla based powders; mean droplet sizes samples; basil oil; tomato; lupin protein; oil; skim milk, soymilk; coconut milk; tomato homogenate; corn; egg-yolk, rapeseed and sunflower; Poly(4-vinylpyridine/silica; and Complex 1 until complex 4 approaches from author case study. A relationship is developed between emulsion size and pH. Results clearly show that lower pH offers smaller droplet of emulsion and the opposite occurs when the pH is increased.

  4. Measuring of nonlinearity of dye doped liquid crystals using of self phase modulation effect

    International Nuclear Information System (INIS)

    Abedi, M.; Jafari, A.; Tajalli, H.

    2007-01-01

    Self phase modulation in dye doped liquid crystals has investigated and the nonlinearity of dye doped liquid crystals is measured by this effect. The Self phase modulation effect can be used for producing optical micro rings that have many applications in photonics and laser industries.

  5. Clean Photothermal Heating and Controlled Release From Near Infrared Dye Doped Nanoparticles Without Oxygen Photosensitization

    Science.gov (United States)

    Guha, Samit; Shaw, Scott K.; Spence, Graeme T.; Roland, Felicia M.; Smith, Bradley D.

    2015-01-01

    The photothermal heating and release properties of biocompatible organic nanoparticles, doped with a near-infrared croconaine (Croc) dye, were compared with analogous nanoparticles doped with the common near-infrared dyes ICG and IR780. Separate formulations of lipid-polymer-hybrid nanoparticles and liposomes, each containing Croc dye, absorbed strongly at 808 nm and generated clean laser-induced heating (no production of 1O2 and no photobleaching of the dye). In contrast, laser-induced heating of nanoparticles containing ICG or IR780 produced reactive 1O2 leading to bleaching of the dye and also decomposition of co-encapsulated payload such as the drug Doxorubicin. Croc dye was especially useful as a photothermal agent for laser controlled release of chemically sensitive payload from nanoparticles. Solution state experiments demonstrated repetitive fractional release of water soluble fluorescent dye from the interior of thermosensitive liposomes. Additional experiments used a focused laser beam to control leakage from immobilized liposomes with very high spatial and temporal precision. The results indicate that fractional photothermal leakage from nanoparticles doped with Croc dye is a promising method for a range of controlled release applications. PMID:26149326

  6. Two-center three-electron bonding in ClNH{sub 3} revealed via helium droplet infrared laser Stark spectroscopy: Entrance channel complex along the Cl + NH{sub 3} → ClNH{sub 2} + H reaction

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Christopher P.; Douberly, Gary E., E-mail: douberly@uga.edu [Department of Chemistry, University of Georgia, Athens, Georgia 30602-2556 (United States); Xie, Changjian; Guo, Hua [Department of Chemistry and Chemical Biology, University of New Mexico, Albuquerque, New Mexico 87131 (United States); Kaufmann, Matin [Department of Physical Chemistry II, Ruhr-University Bochum, D-44801 Bochum (Germany)

    2016-04-28

    Pyrolytic dissociation of Cl{sub 2} is employed to dope helium droplets with single Cl atoms. Sequential addition of NH{sub 3} to Cl-doped droplets leads to the formation of a complex residing in the entry valley to the substitution reaction Cl + NH{sub 3} → ClNH{sub 2} + H. Infrared Stark spectroscopy in the NH stretching region reveals symmetric and antisymmetric vibrations of a C{sub 3v} symmetric top. Frequency shifts from NH{sub 3} and dipole moment measurements are consistent with a ClNH{sub 3} complex containing a relatively strong two-center three-electron (2c–3e) bond. The nature of the 2c–3e bonding in ClNH{sub 3} is explored computationally and found to be consistent with the complexation-induced blue shifts observed experimentally. Computations of interconversion pathways reveal nearly barrierless routes to the formation of this complex, consistent with the absence in experimental spectra of two other complexes, NH{sub 3}Cl and Cl–HNH{sub 2}, which are predicted in the entry valley to the hydrogen abstraction reaction Cl + NH{sub 3} → HCl + NH{sub 2}.

  7. Dual-nozzle microfluidic droplet generator

    Science.gov (United States)

    Choi, Ji Wook; Lee, Jong Min; Kim, Tae Hyun; Ha, Jang Ho; Ahrberg, Christian D.; Chung, Bong Geun

    2018-05-01

    The droplet-generating microfluidics has become an important technique for a variety of applications ranging from single cell analysis to nanoparticle synthesis. Although there are a large number of methods for generating and experimenting with droplets on microfluidic devices, the dispensing of droplets from these microfluidic devices is a challenge due to aggregation and merging of droplets at the interface of microfluidic devices. Here, we present a microfluidic dual-nozzle device for the generation and dispensing of uniform-sized droplets. The first nozzle of the microfluidic device is used for the generation of the droplets, while the second nozzle can accelerate the droplets and increase the spacing between them, allowing for facile dispensing of droplets. Computational fluid dynamic simulations were conducted to optimize the design parameters of the microfluidic device.

  8. Colliding droplets: A short film presentation

    Science.gov (United States)

    Hendricks, C. D.

    1981-12-01

    A series of experiments were performed in which liquid droplets were caused to collide. Impact velocities to several meters per second and droplet diameters up to 600 micrometers were used. The impact parameters in the collisions vary from zero to greater than the sum of the droplet radii. Photographs of the collisions were taken with a high speed framing camera in order to study the impacts and subsequent behavior of the droplets.

  9. Electrospun dye-doped fiber networks: lasing emission from randomly distributed cavities

    DEFF Research Database (Denmark)

    Krammer, Sarah; Vannahme, Christoph; Smith, Cameron

    2015-01-01

    Dye-doped polymer fiber networks fabricated with electrospinning exhibit comb-like laser emission. We identify randomly distributed ring resonators being responsible for lasing emission by making use of spatially resolved spectroscopy. Numerical simulations confirm this result quantitatively....

  10. Droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling for simpler and faster PCR assay using wire-guided manipulations.

    Science.gov (United States)

    You, David J; Yoon, Jeong-Yeol

    2012-09-04

    A computer numerical control (CNC) apparatus was used to perform droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling on a single superhydrophobic surface and a multi-chambered PCB heater. Droplets were manipulated using "wire-guided" method (a pipette tip was used in this study). This methodology can be easily adapted to existing commercial robotic pipetting system, while demonstrated added capabilities such as vibrational mixing, high-speed centrifuging of droplets, simple DNA extraction utilizing the hydrophobicity difference between the tip and the superhydrophobic surface, and rapid thermocycling with a moving droplet, all with wire-guided droplet manipulations on a superhydrophobic surface and a multi-chambered PCB heater (i.e., not on a 96-well plate). Serial dilutions were demonstrated for diluting sample matrix. Centrifuging was demonstrated by rotating a 10 μL droplet at 2300 round per minute, concentrating E. coli by more than 3-fold within 3 min. DNA extraction was demonstrated from E. coli sample utilizing the disposable pipette tip to cleverly attract the extracted DNA from the droplet residing on a superhydrophobic surface, which took less than 10 min. Following extraction, the 1500 bp sequence of Peptidase D from E. coli was amplified using rapid droplet thermocycling, which took 10 min for 30 cycles. The total assay time was 23 min, including droplet centrifugation, droplet DNA extraction and rapid droplet thermocycling. Evaporation from of 10 μL droplets was not significant during these procedures, since the longest time exposure to air and the vibrations was less than 5 min (during DNA extraction). The results of these sequentially executed processes were analyzed using gel electrophoresis. Thus, this work demonstrates the adaptability of the system to replace many common laboratory tasks on a single platform (through re-programmability), in rapid succession (using droplets), and with a high level of

  11. Droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling for simpler and faster PCR assay using wire-guided manipulations

    Directory of Open Access Journals (Sweden)

    You David J

    2012-09-01

    Full Text Available Abstract A computer numerical control (CNC apparatus was used to perform droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling on a single superhydrophobic surface and a multi-chambered PCB heater. Droplets were manipulated using “wire-guided” method (a pipette tip was used in this study. This methodology can be easily adapted to existing commercial robotic pipetting system, while demonstrated added capabilities such as vibrational mixing, high-speed centrifuging of droplets, simple DNA extraction utilizing the hydrophobicity difference between the tip and the superhydrophobic surface, and rapid thermocycling with a moving droplet, all with wire-guided droplet manipulations on a superhydrophobic surface and a multi-chambered PCB heater (i.e., not on a 96-well plate. Serial dilutions were demonstrated for diluting sample matrix. Centrifuging was demonstrated by rotating a 10 μL droplet at 2300 round per minute, concentrating E. coli by more than 3-fold within 3 min. DNA extraction was demonstrated from E. coli sample utilizing the disposable pipette tip to cleverly attract the extracted DNA from the droplet residing on a superhydrophobic surface, which took less than 10 min. Following extraction, the 1500 bp sequence of Peptidase D from E. coli was amplified using rapid droplet thermocycling, which took 10 min for 30 cycles. The total assay time was 23 min, including droplet centrifugation, droplet DNA extraction and rapid droplet thermocycling. Evaporation from of 10 μL droplets was not significant during these procedures, since the longest time exposure to air and the vibrations was less than 5 min (during DNA extraction. The results of these sequentially executed processes were analyzed using gel electrophoresis. Thus, this work demonstrates the adaptability of the system to replace many common laboratory tasks on a single platform (through re-programmability, in rapid succession (using droplets

  12. Spectral tuning of lasing emission from optofluidic droplet microlasers using optical stretching

    Czech Academy of Sciences Publication Activity Database

    Aas, M.; Jonáš, A.; Kiraz, A.; Ježek, Jan; Brzobohatý, Oto; Pilát, Zdeněk; Zemánek, Pavel

    2013-01-01

    Roč. 21, č. 18 (2013), s. 21380-21394 ISSN 1094-4087 R&D Projects: GA ČR GPP205/11/P294; GA MŠk ED0017/01/01; GA TA ČR TA03010642 Institutional support: RVO:68081731 Keywords : Microcavities * Dye lasers * Optical tweezers * Optical manipulation * Fluorescence, laser-induced Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.525, year: 2013

  13. Dye gain gold NW array of surface plasmon polariton waveguide

    Directory of Open Access Journals (Sweden)

    Jun Zhu

    Full Text Available Plasmon lasers can support ultrasmall mode confinement and ultrafast dynamics with device feature sizes below the diffraction limit. At present in the single visible light frequency, the optical gain method of constraint SPP on metal nanowires structure reported less. We design the gold nanowire array structure, consisting of PMMA and R6G dye molecules as gain, by 488 nm pump in the middle of the nanowires position for wide range of light, use symmetry broken overcome that momentum does not match the photonic and SPP energy conversion. Theoretical analysis shows that dyes provide coherent optical feedback, resulting in nanowires face will observe laser properties of surface plasmons. Feature analysis: the incident light and pump joint strength is greater than the sum of strength which is the incident light, pump respectively. Under the effect of dye molecules gain effective, length of SPP transmission can increase 1 µm. The results achieved in a single optical frequency of stimulated radiation, application of dye optical gain can achieve continuous gain effect. This is for the future development of plasma amplifier and the wavelength laser. Keywords: SPP, Stimulated radiation, Gold nanowires array, Dye molecules

  14. Bringing Clouds into Our Lab! - The Influence of Turbulence on the Early Stage Rain Droplets

    Science.gov (United States)

    Yavuz, Mehmet Altug; Kunnen, Rudie; Heijst, Gertjan; Clercx, Herman

    2015-11-01

    We are investigating a droplet-laden flow in an air-filled turbulence chamber, forced by speaker-driven air jets. The speakers are running in a random manner; yet they allow us to control and define the statistics of the turbulence. We study the motion of droplets with tunable size (Stokes numbers ~ 0.13 - 9) in a turbulent flow, mimicking the early stages of raindrop formation. 3D Particle Tracking Velocimetry (PTV) together with Laser Induced Fluorescence (LIF) methods are chosen as the experimental method to track the droplets and collect data for statistical analysis. Thereby it is possible to study the spatial distribution of the droplets in turbulence using the so-called Radial Distribution Function (RDF), a statistical measure to quantify the clustering of particles. Additionally, 3D-PTV technique allows us to measure velocity statistics of the droplets and the influence of the turbulence on droplet trajectories, both individually and collectively. In this contribution, we will present the clustering probability quantified by the RDF for different Stokes numbers. We will explain the physics underlying the influence of turbulence on droplet cluster behavior. This study supported by FOM/NWO Netherlands.

  15. Optofluidic lens actuated by laser-induced solutocapillary forces

    Science.gov (United States)

    Malyuk, A. Yu.; Ivanova, N. A.

    2017-06-01

    We demonstrate an adaptive liquid lens controlled by laser-induced solutocapillary forces. The liquid droplet serving as a lens is formed in a thin layer of binary liquid mixture by surface tension driven flows caused by the thermal action of laser irradiation. The shape of droplet, its aperture and the focal length are reversibly changed without hysteresis by varying the intensity of the laser beam. The focal length variation range of the droplet-lens lies in between infinity (a flat layer) to 15 mm (a curved interface). The droplet-lens is capable to adjust the in-plane lateral position in response to a displacement of the laser beam. The proposed laser controlled droplet-lens will enable to develop smart liquid optical devices, which can imitate the accommodation reflex and pupillary light reflex of the eye.

  16. Some Physics Inside Drying Droplets

    Indian Academy of Sciences (India)

    IAS Admin

    trial applications in food, biochemical or soil sciences. .... Take a metal spoon (or any other surface that does ..... samples. The shape of the suspended particles inside the droplet itself can be used to eliminate the coffee ring effect. For example ...

  17. Vapor-droplet flow equations

    International Nuclear Information System (INIS)

    Crowe, C.T.

    1975-01-01

    General features of a vapor-droplet flow are discussed and the equations expressing the conservation of mass, momentum, and energy for the vapor, liquid, and mixture using the control volume approach are derived. The phenomenological laws describing the exchange of mass, momentum, and energy between phases are also reviewed. The results have application to development of water-dominated geothermal resources

  18. Droplets, Bubbles and Ultrasound Interactions

    NARCIS (Netherlands)

    Shpak, O.; Verweij, M.; de Jong, N.; Versluis, Michel; Escoffre, J.M.; Bouakaz, A.

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to

  19. Liquid droplet radiator performance studies

    Science.gov (United States)

    Mattick, A. T.; Hertzberg, A.

    By making use of droplets rather than solid surfaces to radiate waste heat in space, the liquid droplet radiator (LDR) achieves a radiating area/mass much larger than that of conventional radiators which use fins or heat pipes. The lightweight potential of the LDR is shown to be limited primarily by the radiative properties of the droplets. The requirement that the LDR heat transfer fluid have a very low vapor pressure limits the choice of fluids to relatively few—several liquid metals and Dow 705 silicone fluid are the only suitable candidates so far identified. An experimental determination of the emittance of submillimeter droplets of Dow 705 fluid indicates than an LDR using this fluid at temperatures of 275-335 K would be ⋍ 10 times lighter than the lightest solid surface radiators. Although several liquid metals appear to offer excellent performance in LDR applications at temperatures between 200 K and 975 K, experimental determination of liquid metal emissivities is needed for a conclusive assessment.

  20. Spin lattices of walking droplets

    Science.gov (United States)

    Saenz, Pedro; Pucci, Giuseppe; Goujon, Alexis; Dunkel, Jorn; Bush, John

    2017-11-01

    We present the results of an experimental investigation of the spontaneous emergence of collective behavior in spin lattice of droplets walking on a vibrating fluid bath. The bottom topography consists of relatively deep circular wells that encourage the walking droplets to follow circular trajectories centered at the lattice sites, in one direction or the other. Wave-mediated interactions between neighboring drops are enabled through a thin fluid layer between the wells. The sense of rotation of the walking droplets may thus become globally coupled. When the coupling is sufficiently strong, interactions with neighboring droplets may result in switches in spin that lead to preferred global arrangements, including correlated (all drops rotating in the same direction) or anti-correlated (neighboring drops rotating in opposite directions) states. Analogies with ferromagnetism and anti-ferromagnetism are drawn. Different spatial arrangements are presented in 1D and 2D lattices to illustrate the effects of topological frustration. This work was supported by the US National Science Foundation through Grants CMMI-1333242 and DMS-1614043.

  1. Some Physics Inside Drying Droplets

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 19; Issue 2. Some Physics Inside Drying Droplets. Dileep Mampallil. General Article Volume 19 Issue 2 February 2014 pp 123-134. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/019/02/0123-0134 ...

  2. Reentrainment of droplet from grid spacer in mist flow portion of LOCA reflood of PWR

    International Nuclear Information System (INIS)

    Lee, S.L.; Cho, S.K.; Sheen, H.J.

    1983-01-01

    An investigation is made on the influence of a quenched grid spacer on the greatly enhanced heat transfer from heated fuel rods during the mist flow phase of emergency reflood of loss of coolant accident (LOCA) of a pressurized water reactor (PWR). The situation for the case of a dry grid spacer before its quenching has not been covered in this study. The experimental technique used is a relatively simple optical scheme which combines the reference-mode laser-Doppler anemometry making use of the scattering of a light beam from a droplet. The results reveal that the large droplets in the mist flow, which are intercepted by the grid spacer, are responsible for the creation of a large number of smaller droplets. These small droplets, due to their large surface area to mass ratios, can serve as superb evaporative cooling agents to heat transfer downstream of the grid spacer

  3. Lasers in Ophthalmology

    Institute of Scientific and Technical Information of China (English)

    1992-01-01

    In recent years,lasers have entered every fieldof medicine and especially so in ophthalmol-ogy.The scientific basis of lasers in ophthal-mology is based on three mechanisms:1.Photothermal effectLasers:argon,krypton,dye and diodeA thermal effect is generated when laserenergy is absorbed by pigment leading to in-creased vibration and therefore heat content.A

  4. Magnetic polymer microcapsules loaded with Nile Red fluorescent dye

    Science.gov (United States)

    Bartel, Marta; Wysocka, Barbara; Krug, Pamela; Kępińska, Daria; Kijewska, Krystyna; Blanchard, Gary J.; Kaczyńska, Katarzyna; Lubelska, Katarzyna; Wiktorska, Katarzyna; Głowala, Paulina; Wilczek, Marcin; Pisarek, Marcin; Szczytko, Jacek; Twardowski, Andrzej; Mazur, Maciej

    2018-04-01

    Fabrication of multifunctional smart vehicles for drug delivery is a fascinating challenge of multidisciplinary research at the crossroads of materials science, physics and biology. We demonstrate a prototypical microcapsule system that is capable of encapsulating hydrophobic molecules and at the same time reveals magnetic properties. The microcapsules are prepared using a templated synthesis approach where the molecules to be encapsulated (Nile Red) are present in the organic droplets that are suspended in the polymerization solution which also contains magnetic nanoparticles. The polymer (polypyrrole) grows on the surface of organic droplets encapsulating the fluorescent dye in the core of the formed microcapsule which incorporates the nanoparticles into its wall. For characterization of the resulting structures a range of complementary physicochemical methodology is used including optical and electron microscopy, magnetometry, 1H NMR and spectroscopy in the visible and X-ray spectral ranges. Moreover, the microcapsules have been examined in biological environment in in vitro and in vivo studies.

  5. Droplet and multiphase effects in a shock-driven hydrodynamic instability with reshock

    Science.gov (United States)

    Middlebrooks, John B.; Avgoustopoulos, Constantine G.; Black, Wolfgang J.; Allen, Roy C.; McFarland, Jacob A.

    2018-06-01

    Shock-driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching applications in engineering and science such as high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase field is impulsively accelerated by a shock wave and evolves as a result of gradients in particle-gas momentum transfer. A new shock tube facility has been constructed to study the SDMI. Experiments were conducted to investigate liquid particle and multiphase effects in the SDMI. A multiphase cylindrical interface was created with water droplet laden air in our horizontal shock tube facility. The interface was accelerated by a Mach 1.66 shock wave, and its reflection from the end wall. The interface development was captured using laser illumination and a high-resolution CCD camera. Laser interferometry was used to determine the droplet size distribution. A particle filtration technique was used to determine mass loading within an interface and verify particle size distribution. The effects of particle number density, particle size, and a secondary acceleration (reshock) of the interface were noted. Particle number density effects were found comparable to Atwood number effects in the Richtmyer-Meshkov instability for small (˜ 1.7 {μ }m) droplets. Evaporation was observed to alter droplet sizes and number density, markedly after reshock. For large diameter droplets (˜ 10.7 {μ }m), diminished development was observed with larger droplets lagging far behind the interface. These lagging droplets were also observed to breakup after reshock into structured clusters of smaller droplets. Mixing width values were reported to quantify mixing effects seen in images.

  6. Numerical and experimental studies of droplet-gas flow

    Energy Technology Data Exchange (ETDEWEB)

    Joesang, Aage Ingebret

    2002-07-01

    This thesis considers droplet-gas flow by the use of numerical methods and experimental verification. A commercial vane separator was studied both numerical and by experiment. In addition some efforts are put into the numerical analysis of cyclones. The experimental part contains detailed measurements of the flow field between a pair of vanes in a vane separator and droplet size measurements. LDA (Laser Doppler Anemometry) was used to measure the velocity in two dimensions and corresponding turbulence quantities. The results from the LDA measurements are considered to be of high quality and are compared to numerical results obtained from a CFD (Computational Fluid Dynamics) analysis. The simulation showed good agreement between the numerical and experimental results. Combinations of different turbulence models; the standard k-epsilon model and the Reynold Stress Mode, different schemes; first order and higher order scheme and different near wall treatment of the turbulence; the Law of the wall and the Two-Layer Zonal model were used in the simulations. The Reynold Stress Model together with a higher order scheme performed rather poorly. The recirculation in parts of the separator was overpredicted in this case. For the other cases the overall predictions are satisfactory. PDA (Phase Doppler Anemometry) measurements were used to study the changes in the droplet size distribution through the vane separator. The PDA measurements show that smaller droplets are found at the outlet than present at the inlet. In the literature there exists different mechanisms for explaining the re-entrainment and generation of new droplets. The re-entrainments mechanisms are divided into four groups where droplet-droplet interaction, droplet break-up, splashing of impinging droplet and re-entrainment from the film are defined as the groups of re-entrainment mechanisms. Models for these groups are found in the literature and these models are tested for re-entrainment using the operational

  7. Laser spectroscopy of radioactive barium and strontium isotopes

    International Nuclear Information System (INIS)

    Martin, A.G.

    1986-01-01

    An atomic beam system and a high resolution computer controlled dye laser system were developed to perform isotope shift measurements on accelerator-produced radioactive isotopes. Two different techniques were used to transport the radioactive isotopes to the laser interaction region. The first technique was based on the thermalization and deionization of the nuclear reaction products in a helium buffer gas. The reaction products were subsequently transported in the gas to the laser beam along a capillary tube. This technique suffered from problems with chemical reactions between impurities in the buffer gas and the reaction products and proved to be unsuccessful. The second technique was based on the implantation of the reaction products into a metal lattice. Subsequent heating of the metal lattice released the implanted ions from which an atomic beam was formed. The photon burst technique was used to enable detection of the extremely weak atomic beams formed in this manner. Measurements were performed of the known isotope shifts of radioactive 128 Ba and 126 Ba to test the sensitivity of the system. The previously unmeasured isotope shift of radioactive 82 Sr also was determined, and the result obtained was compared to predictions using the droplet model

  8. Sub-wavelength plasmon laser

    Science.gov (United States)

    Bora, Mihail; Bond, Tiziana C.

    2016-04-19

    A plasmonic laser device has resonant nanocavities filled with a gain medium containing an organic dye. The resonant plasmon frequencies of the nanocavities are tuned to align with both the absorption and emission spectra of the dye. Variables in the system include the nature of the dye and the wavelength of its absorption and emission, the wavelength of the pumping radiation, and the resonance frequencies of the nanocavities. In addition the pumping frequency of the dye is selected to be close to the absorption maximum.

  9. Treatment of dyeing wastewater including reactive dyes (Reactive ...

    African Journals Online (AJOL)

    Fungal growth was not observed at pH 2. Maximum fungal decolourisation ocurred at pH 3 for anionic reactive dyes (RR, RBB, RB) and pH 6 for cationic MB dye. The fungal dye bioremoval was associated with the surface charge of the fungus due to electrostatic interactions. Growing R. arrhizus strain decolourised 100% of ...

  10. Hair cosmetics: dyes.

    Science.gov (United States)

    Guerra-Tapia, A; Gonzalez-Guerra, E

    2014-11-01

    Hair plays a significant role in body image, and its appearance can be changed relatively easily without resort to surgical procedures. Cosmetics and techniques have therefore been used to change hair appearance since time immemorial. The cosmetics industry has developed efficient products that can be used on healthy hair or act on concomitant diseases of the hair and scalp. Dyes embellish the hair by bleaching or coloring it briefly, for temporary periods of longer duration, or permanently, depending on the composition of a dye (oxidative or nonoxidative) and its degree of penetration of the hair shaft. The dermatologist's knowledge of dyes, their use, and their possible side effects (contact eczema, cancer, increased porosity, brittleness) can extend to an understanding of cosmetic resources that also treat hair and scalp conditions. Copyright © 2013 Elsevier España, S.L.U. and AEDV. All rights reserved.

  11. Dancing droplets: Contact angle, drag, and confinement

    Science.gov (United States)

    Benusiglio, Adrien; Cira, Nate; Prakash, Manu

    2015-11-01

    When deposited on a clean glass slide, a mixture of water and propylene glycol forms a droplet of given contact angle, when both pure liquids spread. (Cira, Benusiglio, Prakash: Nature, 2015). The droplet is stabilized by a gradient of surface tension due to evaporation that induces a Marangoni flow from the border to the apex of the droplets. The apparent contact angle of the droplets depends on both their composition and the external humidity as captured by simple models. These droplets present remarkable properties such as lack of a large pinning force. We discuss the drag on these droplets as a function of various parameters. We show theoretical and experimental results of how various confinement geometries change the vapor gradient and the dynamics of droplet attraction.

  12. Hair Dye and Hair Relaxers

    Science.gov (United States)

    ... For Consumers Consumer Information by Audience For Women Hair Dye and Hair Relaxers Share Tweet Linkedin Pin it More sharing ... products. If you have a bad reaction to hair dyes and relaxers, you should: Stop using the ...

  13. Frequency tripling with multimode-lasers

    International Nuclear Information System (INIS)

    Langer, H.; Roehr, H.; Wrobel, W.G.

    1978-10-01

    The presence of different modes with random phases in a laser beam leads to fluctuations in nonlinear optical interactions. This paper describes the influence of the linewidth of a dye laser on the generation of intensive Lyman-alpha radiation by frequency tripling. Using this Lyman-alpha source for resonance scattering on strongly doppler-broadened lines in fusion plasmas the detection limit of neutral hydrogen is nearly two orders higher with the multimode than the singlemode dye laser. (orig.) [de

  14. Cough aerosol in healthy participants: fundamental knowledge to optimize droplet-spread infectious respiratory disease management.

    Science.gov (United States)

    Zayas, Gustavo; Chiang, Ming C; Wong, Eric; MacDonald, Fred; Lange, Carlos F; Senthilselvan, Ambikaipakan; King, Malcolm

    2012-03-21

    The Influenza A H1N1 virus can be transmitted via direct, indirect, and airborne route to non-infected subjects when an infected patient coughs, which expels a number of different sized droplets to the surrounding environment as an aerosol. The objective of the current study was to characterize the human cough aerosol pattern with the aim of developing a standard human cough bioaerosol model for Influenza Pandemic control. 45 healthy non-smokers participated in the open bench study by giving their best effort cough. A laser diffraction system was used to obtain accurate, time-dependent, quantitative measurements of the size and number of droplets expelled by the cough aerosol. Voluntary coughs generated droplets ranging from 0.1 - 900 microns in size. Droplets of less than one-micron size represent 97% of the total number of measured droplets contained in the cough aerosol. Age, sex, weight, height and corporal mass have no statistically significant effect on the aerosol composition in terms of size and number of droplets. We have developed a standard human cough aerosol model. We have quantitatively characterized the pattern, size, and number of droplets present in the most important mode of person-to-person transmission of IRD: the cough bioaerosol. Small size droplets (< 1 μm) predominated the total number of droplets expelled when coughing. The cough aerosol is the single source of direct, indirect and/or airborne transmission of respiratory infections like the Influenza A H1N1 virus. Open bench, Observational, Cough, Aerosol study. © 2012 Zayas et al; licensee BioMed Central Ltd.

  15. Shear-driven redistribution of surfactant affects enzyme activity in well-mixed femtoliter droplets.

    Science.gov (United States)

    Liu, Yu; Jung, Seung-Yong; Collier, C Patrick

    2009-06-15

    We developed a microfluidic platform for splitting well-mixed, femtoliter-volume droplets from larger water-in-oil plugs, where the sizes of the daughter droplets were not limited by channel width. These droplets were separated from mother plugs at a microfabricated T-junction, which enabled the study of how increased confinement affected enzyme kinetics in droplets 4-10 microm in diameter. Initial rates for enzyme catalysis in the mother plugs and the largest daughter drops were close to the average bulk rate, while the rates in smaller droplets decreased linearly with increasing surface to volume ratio. Rates in the smallest droplets decreased by a factor of 4 compared to the bulk rate. Traditional methods for detecting nonspecific adsorption at the water-oil interface were unable to detect evidence of enzyme adsorption, including pendant drop tensiometry, laser scanning confocal microscopy of drops containing labeled proteins in microemulsions, and epifluorescence microscopy of plugs and drops generated on-chip. We propose the slowing of enzyme reaction kinetics in the smaller droplets was the result of increased adsorption and inactivation of enzymes at the water-oil interface arising from transient interfacial shear stresses imparted on the daughter droplets as they split from the mother plugs and passed through the constricted opening of the T-junction. Such stresses are known to modulate the interfacial area and density of surfactant molecules that can passivate the interface. Bright field images of the splitting processes at the junction indicate that these stresses scaled with increasing surface to volume ratios of the droplets but were relatively insensitive to the average flow rate of plugs upstream of the junction.

  16. Dye filled security seal

    International Nuclear Information System (INIS)

    Wilson, D.C.

    1982-01-01

    A security seal for providing an indication of unauthorized access to a sealed object includes an elongate member to be entwined in the object such that access is denied unless the member is removed. The elongate member has a hollow, pressurizable chamber extending throughout its length that is filled with a permanent dye under greater than atmospheric pressure. Attempts to cut the member and weld it together are revealed when dye flows through a rupture in the chamber wall and stains the outside surface of the member

  17. Monodisperse Water-in-Oil-in-Water (W/O/W Double Emulsion Droplets as Uniform Compartments for High-Throughput Analysis via Flow Cytometry

    Directory of Open Access Journals (Sweden)

    Jing Yan

    2013-12-01

    Full Text Available Here we report the application of monodisperse double emulsion droplets, produced in a single step within partially hydrophilic/partially hydrophobic microfluidic devices, as defined containers for quantitative flow cytometric analysis. Samples with varying fluorophore concentrations were generated, and a clear correlation between dye concentration and fluorescence signals was observed.

  18. Effect of droplet size on the droplet behavior on the heterogeneous surface

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ho Yeon; Son, Sung Wan; Ha, ManYeong [Pusan National University, Busan (Korea, Republic of); Park, Yong Gap [Pusan National University, Busan (Korea, Republic of)

    2017-06-15

    The characteristics of a three-dimensional hemispherical droplet on a heterogeneous surface were studied using the Lattice Boltzmann method (LBM). The hydrophilic surface has a hydrophobic part at the center. The hemispherical droplets are located at the center of the heterogeneous surface. According to the contact angles of hydrophilic and hydrophobic bottom surfaces, the droplet either separates or reaches a new equilibrium state. The separation time varies according to the change in droplet size, and it affects the status of droplet separation. The droplet separation behavior was investigated by analyzing the velocity vector around the phase boundary line. The shape and separation time of a droplet are determined by the contact angle of each surface. The speed of droplet separation increases as the difference in contact angle increases between the hydrophobic surface and hydrophilic surface. The separation status and the separation time of a droplet are also determined by the change of the droplet size. As the size of the droplet decreases, the effect of surface tension decreases, and the separation time of the droplet also decreases. On the other hand, as the droplet becomes larger, the effect of surface tension increases and the time required for the droplet to separate also increases.

  19. Quantum Nanostructures by Droplet Epitaxy

    Directory of Open Access Journals (Sweden)

    Somsak Panyakeow

    2009-02-01

    Full Text Available Droplet epitaxy is an alternative growth technique for several quantum nanostructures. Indium droplets are distributed randomly on GaAs substrates at low temperatures (120-350'C. Under background pressure of group V elements, Arsenic and Phosphorous, InAs and InP nanostructures are created. Quantum rings with isotropic shape are obtained at low temperature range. When the growth thickness is increased, quantum rings are transformed to quantum dot rings. At high temperature range, anisotropic strain gives rise to quantum rings with square holes and non-uniform ring stripe. Regrowth of quantum dots on these anisotropic quantum rings, Quadra-Quantum Dots (QQDs could be realized. Potential applications of these quantum nanostructures are also discussed.

  20. Shape-Shifting Droplet Networks.

    Science.gov (United States)

    Zhang, T; Wan, Duanduan; Schwarz, J M; Bowick, M J

    2016-03-11

    We consider a three-dimensional network of aqueous droplets joined by single lipid bilayers to form a cohesive, tissuelike material. The droplets in these networks can be programed to have distinct osmolarities so that osmotic gradients generate internal stresses via local fluid flows to cause the network to change shape. We discover, using molecular dynamics simulations, a reversible folding-unfolding process by adding an osmotic interaction with the surrounding environment which necessarily evolves dynamically as the shape of the network changes. This discovery is the next important step towards osmotic robotics in this system. We also explore analytically and numerically how the networks become faceted via buckling and how quasi-one-dimensional networks become three dimensional.

  1. Study on laser atomic spectroscopy

    International Nuclear Information System (INIS)

    Lee, Jong Min; Song, Kyu Seok; Jeong, Do Young; Kim, Chul Joong; Han, Phil Soon

    1992-01-01

    Electric discharge type atomic vaporizer is developed for the spectroscopic study on actinide elements. Laser induced fluorescence study on actinide elements is performed by using this high temperature type atomizer. For the effective photoionization of elements, copper vapor laser pumped dye laser and electron beam heating type atomic vaporizer are built and their characteristics are measured. In addition, resonance ionization mass spectroscopic analysis for lead sample as well as laser induced fluorescence study on uranium sample in solution phase is made. (Author)

  2. OPTIMIZATION OF DYEING PARAMETERS TO DYE COTTON WITH CARROT EXTRACTION

    Directory of Open Access Journals (Sweden)

    MIRALLES Verónica

    2017-05-01

    Full Text Available Natural dyes derived from flora and fauna are believed to be safe because of non-toxic, non-carcinogenic and biodegradable nature. Furthermore, natural dyes do not cause pollution and waste water problems. Natural dyes as well as synthetic dyes need the optimum parameters to get a good dyeing. On some occasions, It is necessary the use of mordants to increase the affinity between cellulose fiber and natural dye, but there are other conditions to optimize in the dyeing process, like time, temperature, auxiliary porducts, etc. In addition, the optimum conditions are different depends on the type of dye and the fiber nature. The aim of this work is the use of carrot extract to dye cotton fabric by exhaustion at diverse dyeing conditions. Diffferent dyeing processes were carried out to study the effect of pH condition and the temperature, using 7, 6 and 4 pH values and 95 ºC and 130ºC for an hour. As a result some images of dyed samples are shown. Moreover, to evaluate the colour of each sample CIELAB parameters are analysed obtained by reflexion spectrophotometre. The results showed that the temperature used has an important influence on the colour of the dyed sample.

  3. Can a droplet break up under flow without elongating? Fragmentation of smectic monodisperse droplets

    Science.gov (United States)

    Courbin, L.; Engl, W.; Panizza, P.

    2004-06-01

    We study the fragmentation under shear flow of smectic monodisperse droplets at high volume fraction. Using small angle light scattering and optical microscopy, we reveal the existence of a break-up mechanism for which the droplets burst into daughter droplets of the same size. Surprisingly, this fragmentation process, which is strain controlled and occurs homogeneously in the cell, does not require any transient elongation of the droplets. Systematic experiments as a function of the initial droplet size and the applied shear rate show that the rupture is triggered by an instability of the inner droplet structure.

  4. (MTT) dye reduction assay.

    African Journals Online (AJOL)

    to inhibit proliferation of HeLa cells was determined using the 3443- dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) dye reduction assay. Extracts from roots of Agathisanthemum bojeri, Synaptolepis kirkii and Zanha africana and the leaf extract of Physalis peruviana at a concentration of 10 pg/ml inhibited cell ...

  5. Bimanes and Related Heterocycles as Laser Dyes

    Science.gov (United States)

    1991-01-10

    mixture that contained no more than a trace ig-Bridged syn-Bimanes amount of a solid thought to be a mononitro deriv- ative on the basis of M+ 209 in...disappeared and the solution became yellow. ether, ethanol, ethyl acetate, ethyl benzylacetoace- Traces of chlorine were removed by purging with a tate...methyl phosphite . Coumarins 6, 30, 120, and 314, and neutral alumina (2:3 by wt) was added to the rhodamine 6G, sulforhodamine B and thin layer

  6. Impinging Water Droplets on Inclined Glass Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lance, Blake [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ho, Clifford K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    Multiphase computational models and tests of falling water droplets on inclined glass surfaces were developed to investigate the physics of impingement and potential of these droplets to self-clean glass surfaces for photovoltaic modules and heliostats. A multiphase volume-of-fluid model was developed in ANSYS Fluent to simulate the impinging droplets. The simulations considered different droplet sizes (1 mm and 3 mm), tilt angles (0°, 10°, and 45°), droplet velocities (1 m/s and 3 m/s), and wetting characteristics (wetting=47° contact angle and non-wetting = 93° contact angle). Results showed that the spread factor (maximum droplet diameter during impact divided by the initial droplet diameter) decreased with increasing inclination angle due to the reduced normal force on the surface. The hydrophilic surface yielded greater spread factors than the hydrophobic surface in all cases. With regard to impact forces, the greater surface tilt angles yielded lower normal forces, but higher shear forces. Experiments showed that the experimentally observed spread factor (maximum droplet diameter during impact divided by the initial droplet diameter) was significantly larger than the simulated spread factor. Observed spread factors were on the order of 5 - 6 for droplet velocities of ~3 m/s, whereas the simulated spread factors were on the order of 2. Droplets were observed to be mobile following impact only for the cases with 45° tilt angle, which matched the simulations. An interesting phenomenon that was observed was that shortly after being released from the nozzle, the water droplet oscillated (like a trampoline) due to the "snapback" caused by the surface tension of the water droplet being released from the nozzle. This oscillation impacted the velocity immediately after the release. Future work should evaluate the impact of parameters such as tilt angle and surface wettability on the impact of particle/soiling uptake and removal to investigate ways that

  7. Fundamental characteristics of degradation-recoverable solid-state DFB polymer laser.

    Science.gov (United States)

    Yoshioka, Hiroaki; Yang, Yu; Watanabe, Hirofumi; Oki, Yuji

    2012-02-13

    A novel solid-state dye laser with degradation recovery was proposed and demonstrated. Polydimethylsiloxane was used as a nanoporous solid matrix to enable the internal circulation of dye molecules in the solid state. An internal circulation model for the dye molecules was also proposed and verified numerically by assuming molecular mobility and using a proposed diffusion equation. The durability of the laser was increased 20.5-fold compared with that of a conventional polymethylmethacrylate laser. This novel laser solves the low-durability problem of dye-doped polymer lasers.

  8. Laser spectroscopy of radioactive beams

    International Nuclear Information System (INIS)

    Otten, E.W.

    1983-01-01

    The problem of using the laser spectroscopy in investigations radioactive beams is considered. The main attention is payed to the isotope shift of nuclear charge radii delta 2 >. The general trend of delta 2 > is discussed. Predictions for delta>r 2 < in the framework of the droplet model are given. It is noted that two parameter interpretation of the isotope shift based on the droplet model works the better, the further the distance spans and the clearer the nuclear structure is

  9. Electroporation of micro-droplet encapsulated HeLa cells in oil phase

    KAUST Repository

    Xiao, Kang

    2010-08-27

    Electroporation (EP) is a method widely used to introduce foreign genes, drugs or dyes into cells by permeabilizing the plasma membrane with an external electric field. A variety of microfluidic EP devices have been reported so far. However, further integration of prior and posterior EP processes turns out to be very complicated, mainly due to the difficulty of developing an efficient method for precise manipulation of cells in microfluidics. In this study, by means of a T-junction structure within a delicate microfluidic device, we encapsulated HeLa cells in micro-droplet of poration medium in oil phase before EP, which has two advantages: (i) precise control of cell-encapsulating droplets in oil phase is much easier than the control of cell populations or individuals in aqueous buffers; (ii) this can minimize the electrochemical reactions on the electrodes. Finally, we successfully introduced fluorescent dyes into the micro-droplet encapsulated HeLa cells in oil phase. Our results reflected a novel way to realize the integrated biomicrofluidic system for EP. © 2010 Wiley-VCH Verlag GmbH & Co. KGaA.

  10. Electroporation of micro-droplet encapsulated HeLa cells in oil phase

    KAUST Repository

    Xiao, Kang; Zhang, Mengying; Chen, Shuyu; Wang, Limu; Chang, Donald Choy; Wen, Weijia

    2010-01-01

    Electroporation (EP) is a method widely used to introduce foreign genes, drugs or dyes into cells by permeabilizing the plasma membrane with an external electric field. A variety of microfluidic EP devices have been reported so far. However, further integration of prior and posterior EP processes turns out to be very complicated, mainly due to the difficulty of developing an efficient method for precise manipulation of cells in microfluidics. In this study, by means of a T-junction structure within a delicate microfluidic device, we encapsulated HeLa cells in micro-droplet of poration medium in oil phase before EP, which has two advantages: (i) precise control of cell-encapsulating droplets in oil phase is much easier than the control of cell populations or individuals in aqueous buffers; (ii) this can minimize the electrochemical reactions on the electrodes. Finally, we successfully introduced fluorescent dyes into the micro-droplet encapsulated HeLa cells in oil phase. Our results reflected a novel way to realize the integrated biomicrofluidic system for EP. © 2010 Wiley-VCH Verlag GmbH & Co. KGaA.

  11. [Micro-droplet characterization and its application for amino acid detection in droplet microfluidic system].

    Science.gov (United States)

    Yuan, Huiling; Dong, Libing; Tu, Ran; Du, Wenbin; Ji, Shiru; Wang, Qinhong

    2014-01-01

    Recently, the droplet microfluidic system attracts interests due to its high throughput and low cost to detect and screen. The picoliter micro-droplets from droplet microfluidics are uniform with respect to the size and shape, and could be used as monodispensed micro-reactors for encapsulation and detection of single cell or its metabolites. Therefore, it is indispensable to characterize micro-droplet and its application from droplet microfluidic system. We first constructed the custom-designed droplet microfluidic system for generating micro-droplets, and then used the micro-droplets to encapsulate important amino acids such as glutamic acid, phenylalanine, tryptophan or tyrosine to test the droplets' properties, including the stability, diffusivity and bio-compatibility for investigating its application for amino acid detection and sorting. The custom-designed droplet microfluidic system could generate the uniformed micro-droplets with a controllable size between 20 to 50 microm. The micro-droplets could be stable for more than 20 h without cross-contamination or fusion each other. The throughput of detection and sorting of the system is about 600 micro-droplets per minute. This study provides a high-throughput platform for the analysis and screening of amino acid-producing microorganisms.

  12. The use of fluorescent indoline dyes for side population analysis.

    Science.gov (United States)

    Kohara, Hiroshi; Watanabe, Kohei; Shintou, Taichi; Nomoto, Tsuyoshi; Okano, Mie; Shirai, Tomoaki; Miyazaki, Takeshi; Tabata, Yasuhiko

    2013-01-01

    Dye efflux assay evaluated by flow cytometry is useful for stem cell studies. The side population (SP) cells, characterized by the capacity to efflux Hoechst 33342 dye, have been shown to be enriched for hematopoietic stem cells (HSCs) in bone marrow. In addition, SP cells are isolated from various tissues and cell lines, and are also potential candidates for cancer stem cells. However, ultra violet (UV) light, which is not common for every flow cytometer, is required to excite Hoechst 33342. Here we showed that a fluorescent indoline dye ZMB793 can be excited by 488-nm laser, equipped in almost all the modern flow cytometers, and ZMB793-excluding cells showed SP phenotype. HSCs were exclusively enriched in the ZMB793-excluding cells, while ZMB793 was localized in cytosol of bone marrow lineage cells. The efflux of ZMB793 dye was mediated by ATP binding cassette (ABC) transporter Abcg2. Moreover, staining properties were affected by the side-chain structure of the dyes. These data indicate that the fluorescent dye ZMB793 could be used for the SP cell analysis. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Cryogen spray cooling: Effects of droplet size and spray density on heat removal.

    Science.gov (United States)

    Pikkula, B M; Torres, J H; Tunnell, J W; Anvari, B

    2001-01-01

    Cryogen spray cooling (CSC) is an effective method to reduce or eliminate non-specific injury to the epidermis during laser treatment of various dermatological disorders. In previous CSC investigations, fuel injectors have been used to deliver the cryogen onto the skin surface. The objective of this study was to examine cryogen atomization and heat removal characteristics of various cryogen delivery devices. Various cryogen delivery device types including fuel injectors, atomizers, and a device currently used in clinical settings were investigated. Cryogen mass was measured at the delivery device output orifice. Cryogen droplet size profiling for various cryogen delivery devices was estimated by optically imaging the droplets in flight. Heat removal for various cryogen delivery devices was estimated over a range of spraying distances by temperature measurements in an skin phantom used in conjunction with an inverse heat conduction model. A substantial range of mass outputs were measured for the cryogen delivery devices while heat removal varied by less than a factor of two. Droplet profiling demonstrated differences in droplet size and spray density. Results of this study show that variation in heat removal by different cryogen delivery devices is modest despite the relatively large difference in cryogen mass output and droplet size. A non-linear relationship between heat removal by various devices and droplet size and spray density was observed. Copyright 2001 Wiley-Liss, Inc.

  14. Internal flow and evaporation characteristic inside a water droplet on a vertical vibrating hydrophobic surface

    International Nuclear Information System (INIS)

    Kim Hun; Lim, Hee Chang

    2015-01-01

    This study aims to understand the internal flow and the evaporation characteristics of a deionized water droplet subjected to vertical forced vibrations. To predict and evaluate its resonance frequency, the theories of Lamb, Strani, and Sabetta have been applied. To visualize the precise mode, shape, and internal flow inside a droplet, the experiment utilizes a combination of a high-speed camera, macro lens, and continuous laser. As a result, a water droplet on a hydrophobic surface has its typical shape at each mode, and complicated vortices are observed inside the droplet. In particular, large symmetrical flow streams are generated along the vertical axis at each mode, with a large circulating movement from the bottom to the top and then to the triple contact line along the droplet surface. In addition, a bifurcation-shaped flow pattern is formed at modes 2 and 4, whereas a large ellipsoid-shape flow pattern forms at modes 6 and 8. Mode 4 has the fastest internal flow speed and evaporation rate, followed by modes 8 then 6, with 2 having the slowest of these properties. Each mode has the fastest evaporation rate amongst its neighboring frequencies. Finally, the droplet evaporation under vertical vibration would lead to more rapid evaporation, particularly for mode 4

  15. Internal flow and evaporation characteristic inside a water droplet on a vertical vibrating hydrophobic surface

    Energy Technology Data Exchange (ETDEWEB)

    Kim Hun; Lim, Hee Chang [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of)

    2015-07-15

    This study aims to understand the internal flow and the evaporation characteristics of a deionized water droplet subjected to vertical forced vibrations. To predict and evaluate its resonance frequency, the theories of Lamb, Strani, and Sabetta have been applied. To visualize the precise mode, shape, and internal flow inside a droplet, the experiment utilizes a combination of a high-speed camera, macro lens, and continuous laser. As a result, a water droplet on a hydrophobic surface has its typical shape at each mode, and complicated vortices are observed inside the droplet. In particular, large symmetrical flow streams are generated along the vertical axis at each mode, with a large circulating movement from the bottom to the top and then to the triple contact line along the droplet surface. In addition, a bifurcation-shaped flow pattern is formed at modes 2 and 4, whereas a large ellipsoid-shape flow pattern forms at modes 6 and 8. Mode 4 has the fastest internal flow speed and evaporation rate, followed by modes 8 then 6, with 2 having the slowest of these properties. Each mode has the fastest evaporation rate amongst its neighboring frequencies. Finally, the droplet evaporation under vertical vibration would lead to more rapid evaporation, particularly for mode 4.

  16. Experimental test of liquid droplet radiator performance

    Science.gov (United States)

    Mattick, A. T.; Simon, M. A.

    The liquid droplet radiator (LDR) is a heat rejection system for space power systems wherein an array of heated liquid droplets radiates energy directly to space. The use of submillimeter droplets provides large radiating area-to-mass ratio, resulting in radiator systems which are several times lighter than conventional solid surface radiators. An experiment is described in which the power radiated by an array of 2300 streams of silicone oil droplets is measured to test a previously developed theory of the LDR radiation process. This system would be capable of rejecting several kW of heat in space. Furthermore, it would be suitable as a modular unit of an LDR designed for 100-kW power levels. The experiment provided confirmation of the theoretical dependence of droplet array emissivity on optical depth. It also demonstrated the ability to create an array of more than 1000 droplet streams having a divergence less than 1 degree.

  17. A parameterization of cloud droplet nucleation

    International Nuclear Information System (INIS)

    Ghan, S.J.; Chuang, C.; Penner, J.E.

    1993-01-01

    Droplet nucleation is a fundamental cloud process. The number of aerosols activated to form cloud droplets influences not only the number of aerosols scavenged by clouds but also the size of the cloud droplets. Cloud droplet size influences the cloud albedo and the conversion of cloud water to precipitation. Global aerosol models are presently being developed with the intention of coupling with global atmospheric circulation models to evaluate the influence of aerosols and aerosol-cloud interactions on climate. If these and other coupled models are to address issues of aerosol-cloud interactions, the droplet nucleation process must be adequately represented. Here we introduce a droplet nucleation parametrization that offers certain advantages over the popular Twomey (1959) parameterization

  18. Water Entry by a Train of Droplets

    Science.gov (United States)

    Ohl, Claus-Dieter; Huang, Xin; Chan, Chon U.; Frommhold, Philipp Erhard; Lippert, Alexander

    2014-11-01

    The impact of single droplets on a deep pool is a well-studied phenomenon which reveals reach fluid mechanics. Lesser studied is the impact of a train of droplet and the accompanied formation of largely elongated cavities, in particular for well controlled droplets. The droplets with diameters of 20-40 μm and velocities of approx. 20 m/s are generated with a piezo-actuated nozzle at rates of 200-300 kHz. Individual droplets are selected by electric charging and deflection and the impact is visualized with stroboscopic photography and high-speed videos. We study in particular the formation and shape of the cavity as by varying the number of droplets from one to 64. The cavities reach centimetres in length with lateral diameters of the order of 100 of micrometres.

  19. Characteristics of dye-sensitized solar cells using natural dye

    Energy Technology Data Exchange (ETDEWEB)

    Furukawa, Shoji, E-mail: furukawa@cse.kyutech.ac.j [Graduate School of Computer Science and Systems Engineering, Kyushu Institute of Technology, 680-4 Kawazu, Iizuka-shi, Fukuoka-ken 820-8502 (Japan); Iino, Hiroshi; Iwamoto, Tomohisa; Kukita, Koudai; Yamauchi, Shoji [Graduate School of Computer Science and Systems Engineering, Kyushu Institute of Technology, 680-4 Kawazu, Iizuka-shi, Fukuoka-ken 820-8502 (Japan)

    2009-11-30

    Dye-sensitized solar cells are expected to be used for future clean energy. Recently, most of the researchers in this field use Ruthenium complex as dye in the dye-sensitized solar cells. However, Ruthenium is a rare metal, so the cost of the Ruthenium complex is very high. In this paper, various dye-sensitized solar cells have been fabricated using natural dye, such as the dye of red-cabbage, curcumin, and red-perilla. As a result, it was found that the conversion efficiency of the solar cell fabricated using the mixture of red-cabbage and curcumin was about 0.6% (light source: halogen lamp), which was larger than that of the solar cells using one kind of dye. It was also found that the conversion efficiency was about 1.0% for the solar cell with the oxide semiconductor film fabricated using polyethylene glycol (PEG) whose molecular weight was 2,000,000 and red-cabbage dye. This indicates that the cost performance (defined by [conversion efficiency]/[cost of dye]) of the latter solar cell (dye: red-cabbage) is larger by more than 50 times than that of the solar cell using Ruthenium complex, even if the effect of the difference between the halogen lamp and the standard light source is taken into account.

  20. Energy balance of droplets impinging onto a wall heated above the Leidenfrost temperature

    International Nuclear Information System (INIS)

    Dunand, P.; Castanet, G.; Gradeck, M.; Maillet, D.; Lemoine, F.

    2013-01-01

    Highlights: • Measurement techniques are combined to characterize the heat lost due to liquid vaporization. • The wall heat flux is estimated by infrared thermography associated with inverse heat conduction. • The liquid heating is characterized by the two-color Laser-Induced Fluorescence thermometry. • Results reveal how the heat fluxes vary with the droplet sizes and the Weber number. -- Abstract: This work is an experimental study aiming at characterizing the heat transfers induced by the impingement of water droplets (diameter 80–180 μm) on a thin nickel plate heated by electromagnetic induction. The temperature of the rear face of the nickel sample is measured by means of an infrared camera and the heat removed from the wall due to the presence of the droplets is estimated using a semi-analytical inverse heat conduction model. In parallel, the temperature of the droplets is measured using the two-color Laser-Induced Fluorescence thermometry (2cLIF) which has been extended to imagery for the purpose of these experiments. The measurements of the variation in the droplet temperature occurring during an impact allow determining the sensible heat removed by the liquid. Measurements are performed at wall conditions well above the Leidenfrost temperature. Different values of the Weber numbers corresponding to the bouncing and splashing regimes are tested. Comparisons between the heat flux removed from the wall and the sensible heat gained by the liquid allows estimating the heat flux related to liquid evaporation. Results reveal that the respective level of the droplet sensible heat and the heat lost due to liquid vaporization can vary significantly with the droplet sizes and the Weber number