WorldWideScience

Sample records for drains

  1. Drains and Drainage Capabilities: Quantitative Analysis of Drain Efficiencies

    Directory of Open Access Journals (Sweden)

    Andaç Aykan

    2016-03-01

    Full Text Available Objective: In this study, it was aimed to compare the efficiency of the same type of but different-sized silicone drains at different surgical procedures. Material and Methods: Twenty-four patients, who had different diagnoses and were operated between 2011 and 2013, were included. In all patients, 7- and 10-mm silicone-ended, Jackson–Pratt drains were used. Drains that were under 30 cc/day removed. The connection tube and perforated silicone end were examined due to the clot content. All drain efficiencies were calculated, and the results were statistically analyzed. Results: Seven of the 24 patients (29.2% were males and 17 (70.8% were females; the mean age was 39.0±11.4 years. Totally, 49 drains were used, of which 25 (51% were 7 mm and 24 (49% were 10 mm in size. Median removal time was the 5th day (2–12 for the 7-mm drains and the 6th day (3–14 for the 10-mm drains. There was no statistically significant difference between the groups for drain removal time (p=0.268. Further, there was no difference at the connection tube and silicone end for clot content between the 7- and 10-mm drains (p=0.58. For the drainage volume and efficiency, no difference was observed between the groups (p=0.146. Conclusion: In this study it was observed that there is no difference in the drainage volume and efficiency between different-sized Jackson–Pratt drains.

  2. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  3. Globalization, Brain Drain, and Development

    OpenAIRE

    Docquier, Frédéric; Rapoport, Hillel

    2012-01-01

    This paper reviews four decades of economics research on the brain drain, with a focus on recent contributions and on development issues. We first assess the magnitude, intensity, and determinants of the brain drain, showing that brain drain (or high-skill) migration is becoming a dominant pattern of international migration and a major aspect of globalization. We then use a stylized growth model to analyze the various channels through which a brain drain affects the sending countries and revi...

  4. Using Smoke Injection in Drains to Identify Potential Preferential Pathways in a Drained Arable Field

    Science.gov (United States)

    Nielsen, M. H.; Petersen, C. T.; Hansen, S.

    2014-12-01

    Macropores forming a continuous pathway between the soil surface and subsurface drains favour the transport of many contaminants from agricultural fields to surface waters. The smoke injection method presented by Shipitalo and Gibbs (2000) used for demonstrating and quantifying such pathways has been further developed and used on a drained Danish sandy loam. In order to identify the preferential pathways to drains, smoke was injected in three 1.15 m deep tile drains (total drain length 93 m), and smoke emitting macropores (SEMP) at the soil surface were counted and characterized as producing either strong or weak plumes compared to reference plumes from 3 and 6 mm wide tubes. In the two situations investigated in the present study - an early spring and an autumn situation, smoke only penetrated the soil surface layer via earthworm burrows located in a 1.0 m wide belt directly above the drain lines. However, it is known from previous studies that desiccation fractures in a dry summer situation also can contribute to the smoke pattern. The distance between SEMP measured along the drain lines was on average 0.46 m whereas the average spacing between SEMP with strong plumes was 2.3 m. Ponded water was applied in 6 cm wide rings placed above 52 burrows including 17 reference burrows which did not emit smoke. Thirteen pathways in the soil were examined using dye tracer and profile excavation. SEMP with strong plumes marked the entrance of highly efficient transport pathways conducting surface applied water and dye tracer into the drain. However, no single burrow was traced all the way from the surface into the drain, the dye patterns branched off in a network of other macropores. Water infiltration rates were significantly higher (P drains and surface waters, pathways being associated primarily with unevenly distributed SEMP producing strong smoke plumes.

  5. A prospective randomized study of use of drain versus no drain after burr-hole evacuation of chronic subdural hematoma.

    Science.gov (United States)

    Singh, Amit Kumar; Suryanarayanan, Bhaskar; Choudhary, Ajay; Prasad, Akhila; Singh, Sachin; Gupta, Laxmi Narayan

    2014-01-01

    Chronic subdural hematoma (CSDH) recurs after surgical evacuation in 5-30% of patients. Inserting subdural drain might reduce the recurrence rate, but is not commonly practiced. There are few prospective studies to evaluate the effect of subdural drains. A prospective randomized study to investigate the effect of subdural drains in the on recurrence rates and clinical outcome following burr-hole drainage (BHD) of CSDH was undertaken. During the study period, 246 patients with CSDH were assessed for eligibility. Among 200 patients fulfilling the eligibility criteria, 100 each were assigned to "drain group" (drain inserted into the subdural space following BHD) and "without drain group" (subdural drain was not inserted following BHD) using random allocation software. The primary end point was recurrence needing re-drainage up to a period of 6 months from surgery. Recurrence occurred in 9 of 100 patients with a drain, and 26 of 100 patients in without drain group (P = 0.002). The mortality was 5% in patients with drain and 4% in patients without drain group (P = 0.744). The medical and surgical complications were comparable between the two study groups. Use of a subdural drain after burr-hole evacuation of a CSDH reduces the recurrence rate and is not associated with increased complications.

  6. Americium/curium bushing melter drain tests

    International Nuclear Information System (INIS)

    Smith, M.E.; Hardy, B.J.; Smith, M.E.

    1997-01-01

    Americium and curium were produced in the past at the Savannah River Site (SRS) for research, medical, and radiological applications. They have been stored in a nitric acid solution in an SRS reprocessing facility for a number of years. Vitrification of the americium/curium (Am/Cm) solution will allow the material to be safely stored or transported to the DOE Oak Ridge Reservation. Oak Ridge is responsible for marketing radionuclides for research and medical applications. The bushing melter technology being used in the Am/Cm vitrification research work is also under consideration for the stabilization of other actinides such as neptunium and plutonium. A series of melter drain tests were conducted at the Savannah River Technology Center to determine the relationship between the drain tube assembly operating variables and the resulting pour initiation times, glass flowrates, drain tube temperatures, and stop pour times. Performance criteria such as ability to start and stop pours in a controlled manner were also evaluated. The tests were also intended to provide support of oil modeling of drain tube performance predictions and thermal modeling of the drain tube and drain tube heater assembly. These drain tests were instrumental in the design of subsequent melter drain tube and drain tube heaters for the Am/Cm bushing melter, and therefore in the success of the Am/Cm vitrification and plutonium immobilization programs

  7. Drain Current Modulation of a Single Drain MOSFET by Lorentz Force for Magnetic Sensing Application.

    Science.gov (United States)

    Chatterjee, Prasenjit; Chow, Hwang-Cherng; Feng, Wu-Shiung

    2016-08-30

    This paper reports a detailed analysis of the drain current modulation of a single-drain normal-gate n channel metal-oxide semiconductor field effect transistor (n-MOSFET) under an on-chip magnetic field. A single-drain n-MOSFET has been fabricated and placed in the center of a square-shaped metal loop which generates the on-chip magnetic field. The proposed device designed is much smaller in size with respect to the metal loop, which ensures that the generated magnetic field is approximately uniform. The change of drain current and change of bulk current per micron device width has been measured. The result shows that the difference drain current is about 145 µA for the maximum applied magnetic field. Such changes occur from the applied Lorentz force to push out the carriers from the channel. Based on the drain current difference, the change in effective mobility has been detected up to 4.227%. Furthermore, a detailed investigation reveals that the device behavior is quite different in subthreshold and saturation region. A change of 50.24 µA bulk current has also been measured. Finally, the device has been verified for use as a magnetic sensor with sensitivity 4.084% (29.6 T(-1)), which is very effective as compared to other previously reported works for a single device.

  8. A Rare Complication of Abdominal Drain: Fallopian Tube Herniation Through the Drain Site

    OpenAIRE

    Dilek Uygur; Seval Erdinç; Hülya Dede; Ümit Taşdemir; Oktay Kaymak; Nuri Danışman

    2016-01-01

    Prophylactic drainage of the peritoneal cavity after obstetrical and gynecological surgery is widely practiced. The idea of “when in doubt, drain” is accepted and applied clinically by many surgeons. However, surgically placed drains are not without risk. The present case describes herniation of fallopian tube during the removal of a surgical drain placed after a cesarean section.

  9. A Rare Complication of Abdominal Drain: Fallopian Tube Herniation Through the Drain Site

    Directory of Open Access Journals (Sweden)

    Dilek Uygur

    2016-05-01

    Full Text Available Prophylactic drainage of the peritoneal cavity after obstetrical and gynecological surgery is widely practiced. The idea of “when in doubt, drain” is accepted and applied clinically by many surgeons. However, surgically placed drains are not without risk. The present case describes herniation of fallopian tube during the removal of a surgical drain placed after a cesarean section.

  10. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  11. 21 CFR 868.5995 - Tee drain (water trap).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  12. Development of rationalized system treating floor drain

    International Nuclear Information System (INIS)

    Nakamura, Yasuyuki; Serizawa, Kenichi; Komatsu, Akihiro; Shimizu, Takayuki

    1998-01-01

    Radioactive liquid wastes generated at BWR plants are collected and treated as required. These days, however, generation of floor drain has deceased and HFF (Hollow Fiber Filter) has experienced a wide applicability to several kinds of liquid wastes. We should consider that the floor drain can be mixed and diluted with equipment drain and be purified by HFF. That enables some of the sumps and long priming pipes to be combined. From this point of view, we have developed a highly rationalized waste liquid system. We have evaluated the applicability of this system after an investigation into the generation and properties of floor drain and equipment drain at the latest BWR'S and an on-site test at a typical BWR. (author)

  13. How to remove a chest drain.

    Science.gov (United States)

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  14. 216-Z-8 French drain characterization study

    International Nuclear Information System (INIS)

    Marratt, M.C.; Kasper, R.B.; Van Luik, A.E.

    1984-09-01

    The 216-Z-8 French drain study is one of a series of studies examining historical transuranic waste facilities no longer in use at the Hanford Site. The 216-Z-8 French drain underground disposal system consisted of a large settling tank that overflowed into a French drain. The French drain consisted of two large-diameter, gravel filled, vitrified clay pipes placed on end, end-to-end, over a gravel-filled excavation. The top of the drain was sealed with concrete to prevent the upward flow of waste solution. The waste solution discharged to the 216-Z-8 waste disposal system was a neutralized, transuranic recovery process, filter cake, backflush slurry. The primary objective of this study was to determine the distribution of plutonium and americium beneath the French drain. Transuranic activity under the French drain did not exceed 5 nCi/g in the soil samples obtained from a well within 1 m of the drain structure. Conservative estimates indicated that 4 to 5 m 3 of radioactive contaminated sediments, 10 nCi/g may lie directly under the 216-Z-8 French drain. The secondary objective of the study was to evaluate the possibility of a leak in the settling tank. Results from the analysis of soil samples from wells drilled around the settling tank indicated the presence of low-level transuranic contamination (on the order of 0.001 nci/g) in the soil surrounding the tank. However, the distribution of the contamination does not support a leak as a plausible mechanism to account for the observed activity surrounding the tank. The bulk of the plutonium was confirmed to be in the sludge that remained in the tank; thus, no significant environmental impact would be expected even if there has been a leak

  15. Drain site evisceration of fallopian tube, another reason to discourage abdominal drain: report of a case and brief review of literature.

    Science.gov (United States)

    Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet

    2012-04-01

    Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.

  16. Penrose Drain Migration After Laparoscopic Surgery

    Directory of Open Access Journals (Sweden)

    Pazouki AbdolReza

    2009-05-01

    Full Text Available Laparoscopy has made a revolution in surgical procedures and treatment of various diseases but its complications are still under investigation. Intra-abdominal visceral and vessel injuries, trocar site hernia, and leaving foreign bodies into the peritoneal cavity are among some laparoscopic surgery complications. This is a rare report of Penrose drain migration following incomplete laparoscopic Fundoplication surgery. The patient was a 47- year- old woman, who was a candidate for Touplet Fundoplication via laparoscopic approach due to refractory gastro-esophageal reflux disease (GERD. While wrapping a Penrose drain around the esophagus, the patient had a cardiorespiratory arrest. Attempts to remove the Penrose drain were unsuccessful and the surgical procedure was terminated due to patient's condition. Four months later, after a long period of dysphagia and abdominal pain, the Penrose drain was defecated via rectum.

  17. The health workforce crisis: the brain drain scourge.

    Science.gov (United States)

    Ike, Samuel O

    2007-01-01

    The magnitude of the health workforce crisis engendered by brain drain particularly in Africa, and nay more especially Nigeria, has been assuming increasingly alarming proportions in the past three decades. The challenge it poses in meeting the manpower needs in the healthcare sector as well as in the larger economy of the sending countries is enormous. This paper thus sets out to highlight the scope of this brain drain, its effects and the reasons sustaining it, as well as makes concrete suggestions to help stern the tide. A review of the literature on brain drain with particular emphasis on the health workforce sector was done, with focus on Africa, and specifically Nigeria. Literature search was done using mainly the Medline, as well as local journals. The historical perspectives, with the scope of external and internal brain drain are explored. The glaring effects of brain drain both in the global workforce terrain and specifically in the health sectors are portrayed. The countries affected most and the reasons for brain drain are outlined. Strategic steps to redress the brain drain crisis are proffered in this paper. The health workforce crisis resulting from brain drain must be brought to the front-burner of strategic policy decisions leading to paradigm shift in political, social and economic conditions that would serve as incentives to curb the scourge.

  18. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  19. Device for discharging drain in a control rod driving apparatus

    International Nuclear Information System (INIS)

    Ikeda, Tadasu; Ikuta, Takuzo; Yoshida, Tomiji; Tsukahara, Katsumi.

    1975-01-01

    Object: To efficiently and safely collect and discharge drain by a simple construction in which a drain cover and a drain tank in a control rod driving apparatus are integrally formed, and an overhauling wrench of said apparatus and a drain hose are mounted on the drain tank. Structure: When a mounting bolt is untightened by a torque wrench so as to be removed from a flange surface of the control rod driving apparatus in a nuclear reactor, axial movement of said apparatus is absorbed by a spring so that drain containing a radioactive material is discharged into a drain tank through the flange surface of said apparatus and is then guided into a collecting tank through a drain hose. (Kamimura, M.)

  20. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  1. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    Science.gov (United States)

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  2. Laparoscopic radical prostatectomy: omitting a pelvic drain

    Directory of Open Access Journals (Sweden)

    David Canes

    2008-03-01

    Full Text Available PURPOSE: Our goal was to assess outcomes of a selective drain placement strategy during laparoscopic radical prostatectomy (LRP with a running urethrovesical anastomosis (RUVA using cystographic imaging in all patients. Materials and Methods: A retrospective chart review was performed for all patients undergoing LRP between January 2003 and December 2004. The anastomosis was performed using a modified van Velthoven technique. A drain was placed at the discretion of the senior surgeon when a urinary leak was demonstrated with bladder irrigation, clinical suspicion for a urinary leak was high, or a complex bladder neck reconstruction was performed. Routine postoperative cystograms were obtained. RESULTS: 208 patients underwent LRP with a RUVA. Data including cystogram was available for 206 patients. The overall rate of cystographic urine leak was 5.8%. A drain was placed in 51 patients. Of these, 8 (15.6% had a postoperative leak on cystogram. Of the 157 undrained patients, urine leak was radiographically visible in 4 (2.5%. The higher leak rate in the drained vs. undrained cohort was statistically significant (p = 0.002. Twenty-four patients underwent pelvic lymph node dissection (8 drained, 16 undrained. Three undrained patients developed lymphoceles, which presented clinically on average 3 weeks postoperatively. There were no urinomas or hematomas in either group. CONCLUSIONS: Routine placement of a pelvic drain after LRP with a RUVA is not necessary, unless the anastomotic integrity is suboptimal intraoperatively. Experienced clinical judgment is essential and accurate in identifying patients at risk for postoperative leakage. When suspicion is low, omitting a drain does not increase morbidity.

  3. 46 CFR 45.157 - Scuppers and gravity drains.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  4. Current practice patterns of drain usage amongst UK and Irish surgeons performing bilateral breast reductions: Evidence down the drain.

    Science.gov (United States)

    Sugrue, Conor M; McInerney, Niall; Joyce, Cormac W; Jones, Deidre; Hussey, Alan J; Kelly, Jack L; Kerin, Michael J; Regan, Padraic J

    2015-01-01

    Bilateral breast reduction (BBR) is one of the most frequently performed female breast operations. Despite no evidence supporting efficacy of drain usage in BBRs, postoperative insertion is common. Recent high quality evidence demonstrating potential harm from drain use has subsequently challenged this traditional practice. The aim of this study is to assess the current practice patterns of drains usage by Plastic & Reconstructive and Breast Surgeons in UK and Ireland performing BBRs. An 18 question survey was created evaluating various aspects of BBR practice. UK and Irish Plastic & Reconstructive and Breast Surgeons were invited to participate by an email containing a link to a web-based survey. Statistical analysis was performed with student t-test and chi-square test. Two hundred and eleven responding surgeons were analysed, including 80.1% (171/211) Plastic Surgeons and 18.9% (40/211) Breast Surgeons. Of the responding surgeons, 71.6% (151/211) routinely inserted postoperative drains, for a mean of 1.32 days. Drains were used significantly less by surgeons performing ≥20 BBRs (p = 0.02). With the majority of BBRs performed as an inpatient procedure, there was a trend towards less drain usage in surgeons performing this procedure as an outpatient; however, this was not statistically significant (p = 0.07). Even with the high level of evidence demonstrating the safety of BBR without drains, they are still routinely utilised. In an era of evidence- based medicine, surgeons performing breast reductions must adopt the results from scientific research into their clinical practice.

  5. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    Directory of Open Access Journals (Sweden)

    Ayhan GENCLER

    2009-07-01

    Full Text Available Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems that, in general, developing or underdeveloped countries experience the negative consequences of the brain drain and suffer from the decreases in their human capital. The paper explains the phenomenon of skilled international migration, or brain drain, and summarizes the main global trends in this area.

  6. The management of vacuum neck drains in head and neck surgery and the comparison of two different practice protocols for drain removal.

    Science.gov (United States)

    Kasbekar, A V; Davies, F; Upile, N; Ho, M W; Roland, N J

    2016-01-01

    Introduction The management of vacuum neck drains in head and neck surgery is varied. We aimed to improve early drain removal and therefore patient discharge in a safe and effective manner. Methods The postoperative management of head and neck surgical patients with vacuum neck drains was reviewed retrospectively. A new policy was then implemented to measure drainage three times daily (midnight, 6am, midday). The decision for drain removal was based on the most recent drainage period (at Measuring drainage volumes three times daily allows for more accurate assessment of wound drainage, and this can lead to earlier removal of neck drains and safe discharge.

  7. Generation of airborne Listeria innocua from model floor drains.

    Science.gov (United States)

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  8. Fallopian Tube Herniation through Left Sided Abdominal Drain Site.

    Science.gov (United States)

    Hussain, Khalid; Masood, Jovaria

    2016-06-01

    Intra-abdominal drains have been used since long to prevent intra-abdominal collection, and detect any anastomotic leaks. We report a case of left sided fallopian tube herniation from a left lower abdominal drain site in a 27-year female who underwent caesarian section for breach presentation. Several complications related to drain usage has been described but left sided fallopian tube prolapse through drain site has not been reported in literature.

  9. Fallopian Tube Herniation: An Unusual Complication of Surgical Drain

    OpenAIRE

    Sharma, Lipi; Singh, Alpana; Bhaskaran, Sruthi; Radhika, A. G.; Radhakrishnan, Gita

    2012-01-01

    Background. Surgical drains have been used since time immemorial, but their use is not without complications. By presenting this case we aim to describe an uncommon complication of herniation of fallopian tube following the simple procedure of surgical drain removal. Case Presentation. This case describes a 23-year G2P1L1 who underwent an emergency cesarean section for obstructed labor with intraperitoneal drain insertion. The patient had an uneventful postoperative period, drain was removed ...

  10. Thailand and brain drain

    Directory of Open Access Journals (Sweden)

    Terry Commins

    2009-01-01

    Full Text Available Brain drain has been the subject of research since the 1960s. This research has been hampered by a lack of accurate data from both source and receiving countries on migration and on the losses and gains to developing economies of skilled migration. However, despite these handicaps, research has been able to clearly show that trends are changing and the effect this is having is usually quite different for individual source countries.Thailand, as a developing economy, could be regarded as a source country. Fortunately, Thailand has never ranked highly in terms of brain drain when compared to other states in Asia and while it may not be a significant problem it nonetheless needs to be monitored. Thailand is also somewhat unique in that the migration that has occurred has been almost equally split between secondary and tertiary educated Thais. Thailand also ranks low in terms of tertiary educated population who have migrated when compared to other countries in the region. Globalisation is having a profound effect on the migration of skilled workers. As trade becomes increasingly free, barriers to the movement of services or people are also freed. As the better educated are encouraged to think globally, so too will they be inclined to move globally into the world community.This paper examines Thailand’s position with respect to brain drain, some of the lessons we have learned and some of the steps that are being taken to minimise the impact of the loss of skilled workers, with a particular focus on science and technology. The conclusion is that brain drain should not be viewed as an entirely negative development and that the positive outcomes should be recognised, encouraged and incorporated into policy.

  11. Drain Insertion in Chronic Subdural Hematoma: An International Survey of Practice.

    Science.gov (United States)

    Soleman, Jehuda; Kamenova, Maria; Lutz, Katharina; Guzman, Raphael; Fandino, Javier; Mariani, Luigi

    2017-08-01

    To investigate whether, after the publication of grade I evidence that it reduces recurrence rates, the practice of drain insertion after burr-hole drainage of chronic subdural hematoma has changed. Further, we aimed to document various practice modalities concerning the insertion of a drain adopted by neurosurgeons internationally. We administered a survey to neurosurgeons worldwide with questions relating to the surgical treatment of chronic subdural hematoma, with an emphasis on their practices concerning the use of a drain. The preferred surgical technique was burr-hole drainage (89%). Most surgeons prefer to place a drain (80%), whereas in 56% of the cases the reason for not placing a drain was brain expansion after evacuation. Subdural drains are placed by 50% and subperiosteal drains by 27% of the responders, whereas 23% place primarily a subdural drain if possible and otherwise a subperiosteal drain. Three quarters of the responders leave the drain for 48 hours and give prophylactic antibiotic treatment, mostly a single-shot dose intraoperatively (70%). Routine postoperative computed tomography is done by 59% mostly within 24-48 hours after surgery (94%). Adjunct treatment to surgery rarely is used (4%). The publication of grade I evidence in favor of drain use influenced positively this practice worldwide. Some surgeons are still reluctant to insert a drain, especially when the subdural space is narrow after drainage of the hematoma. The insertion of a subperiosteal drain could be a good alternative solution. However, its outcome and efficacy must be evaluated in larger studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. A study of the complications of small bore 'Seldinger' intercostal chest drains.

    Science.gov (United States)

    Davies, Helen E; Merchant, Shairoz; McGown, Anne

    2008-06-01

    Use of small bore chest drains (drainage over a 12-month period. One hundred consecutive small bore Seldinger (12F) chest drain insertions were evaluated. Few serious complications occurred. However, 21% of the chest drains were displaced ('fell out') and 9% of the drains became blocked. This contributed to high morbidity rates, with 13% of patients requiring repeat pleural procedures. The frequency of drain blockage in pleural effusion was reduced by administration of regular normal saline drain flushes (odds ratio for blockage in flushed drains compared with non-flushed drains 0.04, 95% CI: 0.01-0.37, P < 0.001). Regular chest drain flushes are advocated in order to reduce rates of drain blockage, and further studies are needed to determine optimal fixation strategies that may reduce associated patient morbidity.

  13. Drain Back, Low Flow Solar Combi Systems

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2014-01-01

    Drain Back systems with ETC collectors are tested and analyzed in a Danish - Chinese cooperation project. Experiences from early work at DTU, with drain back, low flow systems, was used to design two systems: 1) One laboratory system at DTU and 2) One demonstration system in a single family house...... in Sorö Denmark. Detailed monitoring and modelling of the system in the DTU lab is done to be able to generalize the results, to other climates and loads and to make design optimizations. The advantage with drain back, low flow systems, is that the system can be made more simple with less components...... and that the performance can be enhanced. A combination of the drain back- and system expansion vessel was tested successfully. Small initial problems with installation and proposals for design improvements to avoid these in practice are described in the paper. Installer education and training is an important step to have...

  14. Circuital model for the spherical geodesic waveguide perfect drain

    Science.gov (United States)

    González, Juan C.; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan C.

    2012-08-01

    The perfect drain for the Maxwell fish eye (MFE) is a non-magnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity that depends on frequency. However, this material is only a theoretical material, so it cannot be used in practical devices. The perfect drain has been claimed as necessary for achieving super-resolution (Leonhardt 2009 New J. Phys. 11 093040), which has increased the interest in practical perfect drains suitable for manufacturing. Here, we present a practical perfect drain that is designed using a simple circuit (made of a resistance and a capacitor) connected to the coaxial line. Moreover, we analyze the super-resolution properties of a device equivalent to the MFE, known as a spherical geodesic waveguide, loaded with this perfect drain. The super-resolution analysis for this device is carried out using COMSOL Multiphysics. The results of simulations predict a super-resolution of up to λ/3000.

  15. Circuital model for the spherical geodesic waveguide perfect drain

    International Nuclear Information System (INIS)

    González, Juan C; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan C

    2012-01-01

    The perfect drain for the Maxwell fish eye (MFE) is a non-magnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity that depends on frequency. However, this material is only a theoretical material, so it cannot be used in practical devices. The perfect drain has been claimed as necessary for achieving super-resolution (Leonhardt 2009 New J. Phys. 11 093040), which has increased the interest in practical perfect drains suitable for manufacturing. Here, we present a practical perfect drain that is designed using a simple circuit (made of a resistance and a capacitor) connected to the coaxial line. Moreover, we analyze the super-resolution properties of a device equivalent to the MFE, known as a spherical geodesic waveguide, loaded with this perfect drain. The super-resolution analysis for this device is carried out using COMSOL Multiphysics. The results of simulations predict a super-resolution of up to λ/3000. (paper)

  16. Method of processing laundry drain

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Y; Oda, A; Yusa, H; Kitamura, M; Horiuchi, S

    1979-09-28

    Purpose: To subject the laundry drain to flocculation precipitation treatment in the prior stage of an inverse osmotic treatment, and subject only the supernatant to the inverse osmotic treatment and the precipitate directly to the condensation treatment, thereby decreasing the frequency of exchange of the inverse osmotic membranes, and reducing the quantity of purifying water. Method: The laundry drain is supplied to a flocculation precipitation tank, and added and mixed with a flocculant and a neutralizing agent, thus being subjected to a flocculation precipitation treatment. The supernatant is transported to a circulation tank through a transportation pipe, and is subjected to an inverse osmotic treatment in inverse osmotic module through the circulation tank, a filter and a high tension pump, and then returned to the circulation tank. The supernatant is thus concentrated to a predetermined concentration by repeating such operations. On the other hand, the precipitate at the bottom part of the flocculation precipitation tank is supplied through the transportation pipe to an evaporator supply tank together with the concentrate from the drain circulation tank, and evaporated and concentrated in the evaporator.

  17. Evisceration of Appendix through the Drain Site: A Rare Case Report.

    Science.gov (United States)

    Ravishankaran, Praveen; Rajamani, A

    2013-06-01

    Placing a drain after surgery is a usual procedure in any emergency abdominal operation. The drain is removed as soon as its purpose of draining the intraabdominal collection in served. Evisceration of intraabdominal organs through the drain site is a rare occurance. This case report is about an 12 year old girl who was admitted with blunt trauma abdomen. After completion of emergency laparotomy a drain was placed in the right lower quadrant. When the drain was removed on the 6th post operative day, the appendix eviscerated out of the drain site. The wound was extended a little and an appendectomy was done. This case is presented for its rarity as only two similar instances have been reported in literature so far.

  18. Mechanical decontamination techniques for floor drain systems

    International Nuclear Information System (INIS)

    Palau, G.L.

    1987-01-01

    The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used

  19. Brain drain of China and India

    OpenAIRE

    Li, Yuan

    2012-01-01

    Abstract Under the background of globalization, brain drain is a common phenomenon in many countries. Talents flow from developing countries to developed countries, and this phenomenon unavoidably exerts various and profound influences to both the source countries and the receiving countries. This thesis deals with the phenomenon of brain drain with the aim to investigate the phenomenon further and carry out two case studies of China and India. The research method is main...

  20. CSER 94-011: Use of glovebags for demister draining operations

    International Nuclear Information System (INIS)

    Hess, A.L.

    1994-01-01

    A criticality safety review is presented for the use of plastic-sheet glovebags for the operations of draining demisters on the 26-inch vacuum system headers. A criticality drain is required because of the possibility for spilling liquid of sufficient volume and fissile content for criticality. It is recommended that the glovebag design include a rigid, 2ft x 2ft floor with a central drain feeding a geometrically favorable spill-catch vessel, plus a screen grid above the bottom for drain protection

  1. Draining after breast reduction: a randomised controlled inter-patient study

    NARCIS (Netherlands)

    Corion, Leonard U. M.; Smeulders, Mark J. C.; van Zuijlen, Paul P. M.; van der Horst, Chantal M. A. M.

    2009-01-01

    One hundred and seven bilateral breast reductions were prospectively randomised during surgery to receive or not receive wound drains. Fifty-five patients were randomised to have a drain and 52 to not have a drain. There was no statistical difference in the number of complications between the

  2. Study of the patency of different peritoneal drains used prophylactically in bariatric surgery.

    Science.gov (United States)

    Salgado Júnior, Wilson; Macedo Neto, Marcelo Martins; dos Santos, José Sebastião; Sakarankutty, Ajith Kumar; Ceneviva, Reginaldo; de Castro e Silva, Orlando

    2009-05-21

    To compare the performance of different types of abdominal drains used in bariatric surgery. A vertical banded Roux-en-Y gastric bypass was performed in 33 morbidly obese patients. Drainage of the peritoneal cavity was performed in each case using three different types of drain selected in a randomized manner: a latex tubular drain, a Watterman tubulolaminar drain, and a silicone channeled drain. Drain permeability, contamination of the drained fluid, ease of handling, and patient discomfort were evaluated postoperatively over a period of 7 d. The patients with the silicone channeled drain had larger volumes of drainage compared to patients with tubular and tubulolaminar drains between the third and seventh postoperative days. In addition, a lower incidence of discomfort and of contamination with bacteria of a more pathogenic profile was observed in the patients with the silicone channeled drain. The silicone channeled drain was more comfortable and had less chance of occlusion, which is important in the detection of delayed dehiscence.

  3. Advances in chest drain management in thoracic disease

    Science.gov (United States)

    George, Robert S.

    2016-01-01

    An adequate chest drainage system aims to drain fluid and air and restore the negative pleural pressure facilitating lung expansion. In thoracic surgery the post-operative use of the conventional underwater seal chest drainage system fulfills these requirements, however they allow great variability amongst practices. In addition they do not offer accurate data and they are often inconvenient to both patients and hospital staff. This article aims to simplify the myths surrounding the management of chest drains following chest surgery, review current experience and explore the advantages of modern digital chest drain systems and address their disease-specific use. PMID:26941971

  4. An Equal-Strain Analytical Solution for the Radial Consolidation of Unsaturated Soils by Vertical Drains considering Drain Resistance

    Directory of Open Access Journals (Sweden)

    Feng Zhou

    2018-01-01

    Full Text Available Developing an analytical solution for the consolidation of unsaturated soils remains a challenging task due to the complexity of coupled governing equations for air and water phases. This paper presents an equal-strain model for the radial consolidation of unsaturated soils by vertical drains, and the effect of drain resistance is also considered. Simplified governing equations are established, and an analytical solution to calculate the excess pore-air and pore-water pressures is derived by using the methods of matrix analysis and eigenfunction expansion. The average degrees of consolidation for air and water phases and the ground surface settlement are also given. The solutions of the equal-strain model are verified by comparing the proposed free-strain model with the equal-strain model, and reasonably good agreement is obtained. Moreover, parametric studies regarding the drain resistance effect are graphically presented.

  5. Percutaneous Retrieval of a Retained Jackson-Pratt Drain Fragment

    International Nuclear Information System (INIS)

    Namyslowski, Jan; Halin, Neil J.; Greenfield, Alan J.

    1996-01-01

    A retained intraabdominal Jackson-Pratt drain fragment was percutaneously retrieved using an inflated angioplasty balloon that had been maneuvered inside of the drain lumen over a hydrophilic-coated steerable guidewire

  6. Laparoscopic elective cholecystectomy with and without drain: A controlled randomised trial

    Directory of Open Access Journals (Sweden)

    Gouda El-labban

    2012-01-01

    Full Text Available Background : Laparoscopic cholecystectomy is the main method of treatment of symptomatic gallstones. Routine drainage after laparoscopic cholecystectomy is an issue of considerable debate. Therefore, a controlled randomised trial was designed to assess the value of drains in elective laparoscopic cholecystectomy. Materials and Methods: During a two-year period (From April 2008 to January 2010, 80 patients were simply randomised to have a drain placed (group A, an 8-mm pentose tube drain was retained below the liver bed, whereas 80 patients were randomised not to have a drain (group B placed in the subhepatic space. End points of this trial were to detect any differences in morbidity, postoperative pain, wound infection and hospital stay between the two groups. Results : There was no mortality in either group and no statistically significant difference in postoperative pain, nausea and vomiting, wound infection or abdominal collection between the two groups. However, hospital stay was longer in the drain group than in group without drain and it is appearing that the use of drain delays hospital discharge. Conclusion : The routine use of a drain in non-complicated laparoscopic cholecystectomy has nothing to offer; in contrast, it is associated with longer hospital stay.

  7. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    OpenAIRE

    Gonzalo García-Ros; Iván Alhama; Manuel Cánovas

    2018-01-01

    The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018), a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD) and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulat...

  8. Iatrogenic Perforation of the Left Ventricle during Insertion of a Chest Drain

    OpenAIRE

    Kim, Dongmin; Lim, Seong-Hoon; Seo, Pil Won

    2013-01-01

    Chest draining is a common procedure for treating pleural effusion. Perforation of the heart is a rare often fatal complication of chest drain insertion. We report a case of a 76-year-old female patient suffering from congestive heart failure. At presentation, unilateral opacity of the left chest observed on a chest X-ray was interpreted as massive pleural effusion, so an attempt was made to drain the left pleural space. Malposition of the chest drain was suspected because blood was draining ...

  9. Horner's syndrome caused by an intercostal chest drain.

    OpenAIRE

    Campbell, P; Neil, T; Wake, P N

    1989-01-01

    Horner's syndrome occurred in a young woman as a complication of the treatment of a traumatic pneumothorax with an intercostal drain. The nerve damage probably occurred when the lung had fully re-expanded, pressing the tip of the intercostal drain, lying at the apex of the pleural cavity, on to the sympathetic chain.

  10. Rethinking "Brain Drain" in the Era of Globalisation

    Science.gov (United States)

    Rizvi, Fazal

    2005-01-01

    This paper discusses a range of issues concerning the idea of "brain drain" within the context of recent thinking on transnational mobility. It argues that the traditional analyses of brain drain are not sufficient, and that we can usefully approach the topic from a postcolonial perspective concerned with issues of identity, national…

  11. Comparison of a large and small-calibre tube drain for managing spontaneous pneumothoraces.

    Science.gov (United States)

    Benton, Ian J; Benfield, Grant F A

    2009-10-01

    To compare treatment success of large- and small-bore chest drains in the treatment of spontaneous pneumothoraces the case-notes were reviewed of those admitted to our hospital with a total of 73 pneumothoraces and who were treated by trainee doctors of varying experience. Both a large- and a small-bore intercostal tube drain system were in use during the two-year period reviewed. Similar pneumothorax profile and numbers treated with both drains were recorded, resulting in a similar drain time and numbers of successful and failed re-expansion of pneumothoraces. Successful pneumothorax resolution was the same for both drain types and the negligible tube drain complications observed with the small-bore drain reflected previously reported experiences. However the large-bore drain was associated with a high complication rate (32%) with more infectious complications (24%). The small-bore drain was prone to displacement (21%). There was generally no evidence of an increased failure and morbidity, reflecting poorer expertise, in the non-specialist trainees managing the pneumothoraces. A practical finding however was that in those large pneumothoraces where re-expansion failed, the tip of the drain had not been sited at the apex of the pleural cavity irrespective of the drain type inserted.

  12. FROM BRAIN DRAIN TO BRAIN NETWORKING

    Directory of Open Access Journals (Sweden)

    Irina BONCEA

    2015-06-01

    Full Text Available Scientific networking is the most accessible way a country can turn the brain drain into brain gain. Diaspora’s members offer valuable information, advice or financial support from the destination country, without being necessary to return. This article aims to investigate Romania’s potential of turning brain drain into brain networking, using evidence from the medical sector. The main factors influencing the collaboration with the country of origin are investigated. The conclusions suggest that Romania could benefit from the diaspora option, through an active implication at institutional level and the implementation of a strategy in this area.

  13. Carbon accumulation in pristine and drained mires

    Energy Technology Data Exchange (ETDEWEB)

    Maekilae, M.

    2011-07-01

    The carbon accumulation of 73 peat columns from 48 pristine and drained mires was investigated using a total of 367 dates and age-depth models derived from bulk density measurements. Peat columns were collected from mires of varying depth, age, degree of natural state and nutrient conditions in aapa mire and raised bog regions and coastal mires from southern and central Finland and Russian Karelia. Particular attention was paid to the accumulation of carbon over the last 300 years, as this period encompasses the best estimates of the oxic layer (acrotelm) age across the range of sites investigated. In general, drained mires are initially more nutrient-rich than pristine mires. Organic matter decomposes more rapidly at drained sites than at pristine sites, resulting in thinner peat layers and carbon accumulation but a higher dry bulk density and carbon content. The average carbon accumulation was calculated as 24.0 g m-2 yr-1 at pristine sites and 19.4 g m-2 yr-1 at drained sites, while for peat layers younger than 300 years the respective figures were 45.3 and 34.5 g m-2 yr-1 at pristine and drained sites. For the <300-year-old peat layers studied here, the average thickness was 19 cm less and the carbon accumulation rate 10.8 g m-2 yr-1 lower in drained areas than in pristine areas. The amount carbon accumulation of surface peat layers depends upon the mire site type, vegetation and natural state; variations reflect differences in plant communities as well as factors that affect biomass production and decay rates. The highest accumulation rates and thus carbon binding for layers younger than 300 years were measured in the ombrotrophic mire site types (Sphagnum fuscum bog and Sphagnum fuscum pine bog), and the second highest rates in wet, treeless oligotrophic and minerotrophic mire site types. The lowest values of carbon accumulation over the last 300 years were obtained for the most transformed, sparsely forested and forested mire site types, where the water

  14. Climate mitigation scenarios of drained peat soils

    Science.gov (United States)

    Kasimir Klemedtsson, Åsa; Coria, Jessica; He, Hongxing; Liu, Xiangping; Nordén, Anna

    2014-05-01

    The national inventory reports (NIR) submitted to the UNFCCC show Sweden - which as many other countries has wetlands where parts have been drained for agriculture and forestry purposes, - to annually emit 12 million tonnes carbon dioxide equivalents, which is more GHG'es than industrial energy use release in Sweden. Similar conditions can be found in other northern countries, having cool and wet conditions, naturally promoting peat accumulation, and where land use management over the last centuries have promoted draining activities. These drained peatland, though covering only 2% of the land area, have emissions corresponding to 20% of the total reported NIR emissions. This substantial emission contribution, however, is hidden within the Land Use Land Use Change and Forestry sector (LULUCF) where the forest Carbon uptake is even larger, which causes the peat soil emissions become invisible. The only drained soil emission accounted in the Swedish Kyoto reporting is the N2O emission from agricultural drained organic soils of the size 0.5 million tonnes CO2e yr-1. This lack of visibility has made incentives for land use change and management neither implemented nor suggested, however with large potential. Rewetting has the potential to decrease soil mineralization, why CO2 and N2O emissions are mitigated. However if the soil becomes very wet CH4 emission will increase together with hampered plant growth. By ecological modeling, using the CoupModel the climate change mitigation potential have been estimated for four different land use scenarios; 1, Drained peat soil with Spruce (business as usual scenario), 2, raised ground water level to 20 cm depth and Willow plantation, 3, raised ground water level to 10 cm depth and Reed Canary Grass, and 4, rewetting to an average water level in the soil surface with recolonizing wetland plants and mosses. We calculate the volume of biomass production per year, peat decomposition, N2O emission together with nitrate and DOC

  15. Method of draining water through a solid waste site without leaching

    Science.gov (United States)

    Treat, Russell L.; Gee, Glendon W.; Whyatt, Greg A.

    1993-01-01

    The present invention is a method of preventing water from leaching solid waste sites by preventing atmospheric precipitation from contacting waste as the water flows through a solid waste site. The method comprises placing at least one drain hole through the solid waste site. The drain hole is seated to prevent waste material from entering the drain hole, and the solid waste site cover material is layered and graded to direct water to flow toward the drain hole and to soil beneath the waste site.

  16. Inverse problem in anisotropic poroelasticity: drained constants from undrained ultrasound measurements.

    Science.gov (United States)

    Berryman, James G; Nakagawa, Seiji

    2010-02-01

    Poroelastic analysis has traditionally focused on the relationship between dry and drained constants, which are assumed known, and the saturated or undrained constants, which are assumed unknown. However, there are many applications in this field of study for which the main measurements can only be made on the saturated/undrained system, and then it is uncertain what the effects of the fluids were on the system, since the drained constants remain a mystery. The work presented here shows how to deduce drained constants from undrained constants for anisotropic systems having symmetries ranging from isotropic to orthotropic. Laboratory ultrasound data are then inverted for the drained constants in three granular packings: one of glass beads, and two others for distinct types of more or less angular sand grain packings. Experiments were performed under uniaxial stress, which resulted in hexagonal (transversely isotropic) symmetry of the poroelastic response. One important conclusion from the general analysis is that the drained constants are uniquely related to the undrained constants, assuming that porosity, grain bulk modulus, and pore fluid bulk modulus are already known. Since the resulting system of equations for all the drained constants is linear, measurement error in undrained constants also propagates linearly into the computed drained constants.

  17. Inverse problem in anisotropic poroelasticity: Drained constants from undrained ultrasound measurements

    Energy Technology Data Exchange (ETDEWEB)

    Berryman, J.G.; Nakagawa, S.

    2009-11-20

    Poroelastic analysis has traditionally focused on the relationship between dry or drained constants which are assumed known and the saturated or undrained constants which are assumed unknown. However, there are many applications in this field of study for which the main measurements can only be made on the saturated/undrained system, and then it is uncertain what the eects of the uids were on the system, since the drained constants remain a mystery. The work presented here shows how to deduce drained constants from undrained constants for anisotropic systems having symmetries ranging from isotropic to orthotropic. Laboratory ultrasound data are then inverted for the drained constants in three granular packings: one of glass beads, and two others for distinct types of more or less angular sand grain packings. Experiments were performed under uniaxial stress, which resulted in hexagonal (transversely isotropic) symmetry of the poroelastic response. One important conclusion from the general analysis is that the drained constants are uniquely related to the undrained constants, assuming that porosity, grain bulk modulus, and pore uid bulk modulus are already known. Since the resulting system of equations for all the drained constants is linear, measurement error in undrained constants also propagates linearly into the computed drained constants.

  18. Detecting peatland drains with Object Based Image Analysis and Geoeye-1 imagery.

    Science.gov (United States)

    Connolly, J; Holden, N M

    2017-12-01

    Peatlands play an important role in the global carbon cycle. They provide important ecosystem services including carbon sequestration and storage. Drainage disturbs peatland ecosystem services. Mapping drains is difficult and expensive and their spatial extent is, in many cases, unknown. An object based image analysis (OBIA) was performed on a very high resolution satellite image (Geoeye-1) to extract information about drain location and extent on a blanket peatland in Ireland. Two accuracy assessment methods: Error matrix and the completeness, correctness and quality (CCQ) were used to assess the extracted data across the peatland and at several sub sites. The cost of the OBIA method was compared with manual digitisation and field survey. The drain maps were also used to assess the costs relating to blocking drains vs. a business-as-usual scenario and estimating the impact of each on carbon fluxes at the study site. The OBIA method performed well at almost all sites. Almost 500 km of drains were detected within the peatland. In the error matrix method, overall accuracy (OA) of detecting the drains was 94% and the kappa statistic was 0.66. The OA for all sub-areas, except one, was 95-97%. The CCQ was 85%, 85% and 71% respectively. The OBIA method was the most cost effective way to map peatland drains and was at least 55% cheaper than either field survey or manual digitisation, respectively. The extracted drain maps were used constrain the study area CO 2 flux which was 19% smaller than the prescribed Peatland Code value for drained peatlands. The OBIA method used in this study showed that it is possible to accurately extract maps of fine scale peatland drains over large areas in a cost effective manner. The development of methods to map the spatial extent of drains is important as they play a critical role in peatland carbon dynamics. The objective of this study was to extract data on the spatial extent of drains on a blanket bog in the west of Ireland. The

  19. Detecting peatland drains with Object Based Image Analysis and Geoeye-1 imagery

    Directory of Open Access Journals (Sweden)

    J. Connolly

    2017-03-01

    Full Text Available Abstract Background Peatlands play an important role in the global carbon cycle. They provide important ecosystem services including carbon sequestration and storage. Drainage disturbs peatland ecosystem services. Mapping drains is difficult and expensive and their spatial extent is, in many cases, unknown. An object based image analysis (OBIA was performed on a very high resolution satellite image (Geoeye-1 to extract information about drain location and extent on a blanket peatland in Ireland. Two accuracy assessment methods: Error matrix and the completeness, correctness and quality (CCQ were used to assess the extracted data across the peatland and at several sub sites. The cost of the OBIA method was compared with manual digitisation and field survey. The drain maps were also used to assess the costs relating to blocking drains vs. a business-as-usual scenario and estimating the impact of each on carbon fluxes at the study site. Results The OBIA method performed well at almost all sites. Almost 500 km of drains were detected within the peatland. In the error matrix method, overall accuracy (OA of detecting the drains was 94% and the kappa statistic was 0.66. The OA for all sub-areas, except one, was 95–97%. The CCQ was 85%, 85% and 71% respectively. The OBIA method was the most cost effective way to map peatland drains and was at least 55% cheaper than either field survey or manual digitisation, respectively. The extracted drain maps were used constrain the study area CO2 flux which was 19% smaller than the prescribed Peatland Code value for drained peatlands. Conclusions The OBIA method used in this study showed that it is possible to accurately extract maps of fine scale peatland drains over large areas in a cost effective manner. The development of methods to map the spatial extent of drains is important as they play a critical role in peatland carbon dynamics. The objective of this study was to extract data on the spatial extent of

  20. Nurses’ Knowledge Levels of Chest Drain Management: A Descriptive Study

    Directory of Open Access Journals (Sweden)

    Merve Tarhan

    2016-12-01

    Full Text Available Objective: The physician is responsible for inserting one or more chest tubes into the pleural space or the mediastinal space and connecting them to an appropriate drainage system. When the general principles about care of patients with chest drains were implemented correctly and effectively by nurses, nurse will contribute to accelerate the healing process of patients. In this context, the aim of this study was to determine the nurses’ level of knowledge regarding the care of patients with chest drains. Methods: The study was conducted with 153 nurses who worked in a chest diseases and thoracic surgery hospital in July 2014. Questionnaire form of 35 questions prepared by investigators was used to collect data. For the analysis of results, frequency tests, independent sample t-test and oneway ANOVA test were used. Results: 69.3% of nurses stated that they had obtained information from colleguages. 35.3% considered their knowledge about chest drain management to be inadequate. 55.6% scored 13 points and above from knowledge questionnaire about chest drain management. There were statistically significant difference between knowledge level and educational background, clinic work type, working unit, years of professional experience and institutional experience, frequency of contact patients with chest drain and perception of knowledge level (p<0.05. Conclusion: Results of this study indicate that lack of evidence-based nursing care and insufficient training has resulted in uncertainty and knowledge deficit in important aspects of chest drain care. It can be concluded that nurses receive training needs and training protocols are about chest drain management.

  1. Controlling the ambipolarity and improvement of RF performance using Gaussian Drain Doped TFET

    Science.gov (United States)

    Nigam, Kaushal; Gupta, Sarthak; Pandey, Sunil; Kondekar, P. N.; Sharma, Dheeraj

    2018-05-01

    Ambipolar conduction in tunnel field-effect transistors (TFETs) has been occurred as an inherent issue due to drain-channel tunneling. It makes TFET less efficient and restricts its application in complementary digital circuits. Therefore, this manuscript reports the application of Gaussian doping profile on nanometer regime silicon channel TFETs to completely eliminate the ambipolarity. For this, Gaussian doping is used in the drain region of conventional gate-drain overlap TFET to control the tunneling of electrons from the valence band of channel to the conduction band of drain. As a result, barrier width at the drain/channel junction increases significantly leading to the suppression of an ambipolar current even when higher doping concentration (1 ? 10 ? cm ?) is considered in the drain region. However, significant improvement in terms of RF figure-of-merits such as cut-off frequency (f ?), gain bandwidth product (GBW), and gate-to-drain capacitance (C ?) is achieved with Gaussian doped gate on drain overlap TFET as compared to its counterpart TFET.

  2. MEDICAL BRAIN DRAIN - A THEORETICAL APPROACH

    Directory of Open Access Journals (Sweden)

    Boncea Irina

    2013-07-01

    Full Text Available Medical brain drain is defined as the migration of health personnel from developing countries to developed countries and between industrialized nations in search for better opportunities. This phenomenon became a global growing concern due to its impact on both the donor and the destination countries. This article aims to present the main theoretical contributions starting from 1950 until today and the historical evolution, in the attempt of correlating the particular case of medical brain drain with the theory and evolution of the brain drain in general. This article raises questions and offers answers, identifies the main issues and looks for possible solutions in order to reduce the emigration of medical doctors. Factors of influence include push (low level of income, poor working conditions, the absence of job openings and social recognition, oppressive political climate and pull (better remuneration and working conditions, prospects for career development, job satisfaction, security factors. Developing countries are confronting with the loss of their most valuable intellectuals and the investment in their education, at the benefit of developed nations. An ethical debate arises as the disparities between countries increases, industrialized nations filling in the gaps in health systems with professionals from countries already facing shortages. However, recent literature emphasizes the possibility of a “beneficial brain drain” through education incentives offered by the emigration prospects. Other sources of “brain gain” for donor country are the remittances, the scientific networks and return migration. Measures to stem the medical brain drain involve the common effort and collaboration between developing and developed countries and international organizations. Measures adopted by donor countries include higher salaries, better working conditions, security, career opportunities, incentives to stimulate return migration. Destination

  3. Brain drain: Propulsive factors and consequences

    Directory of Open Access Journals (Sweden)

    Dragan ILIC

    2018-01-01

    Full Text Available When speaking about the total number of highly educated individuals’ migration, it is easy to spot that it is rapidly increasing. The brain drain issues should be taken very seriously especially in under developed and in the developing countries, knowing that the human capital is globally mobile and that highly educated individuals can without any issues market their knowledge around the globe. Dealing with it requires a carefully tailored strategy for these countries, which are suffering from severe human capital losses on annual basis. Since the labor markets of today are highly competitive, it is necessary for these countries to secure good advancement and doing business opportunities. The purpose of this research is to provide an insight into the key propulsive factors and potential consequences caused by the brain drain. The method used in order to conduct the research was a carefully designed questionnaire taken by the date subject enrolled at the third and fourth years of state governed and privately owned universities. This research shows that one of the key reasons for brain drain in underdeveloped and in the developing countries is shortage of further educational advancement opportunities.

  4. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.

    Science.gov (United States)

    Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho

    2011-05-01

    A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  5. Steam generator fitted with a dynamic draining device

    International Nuclear Information System (INIS)

    Chaix, J.E.

    1982-01-01

    This generator has, at its upper part, at least one drying structure for holding the water carried with the steam and communicating at its lower part with at least one discharge pipe for draining off the water, each pipe communicating with a dynamic draining device capable of creating a depression in order to suck up the water contained in the drying structure. Application is for pressurized water nuclear reactors [fr

  6. Leaching of dissolved phosphorus from tile-drained agricultural areas.

    Science.gov (United States)

    Andersen, H E; Windolf, J; Kronvang, B

    2016-01-01

    We investigated leaching of dissolved phosphorus (P) from 45 tile-drains representing animal husbandry farms in all regions of Denmark. Leaching of P via tile-drains exhibits a high degree of spatial heterogeneity with a low concentration in the majority of tile-drains and few tile-drains (15% in our investigation) having high to very high concentration of dissolved P. The share of dissolved organic P (DOP) was high (up to 96%). Leaching of DOP has hitherto been a somewhat overlooked P loss pathway in Danish soils and the mechanisms of mobilization and transport of DOP needs more investigation. We found a high correlation between Olsen-P and water extractable P. Water extractable P is regarded as an indicator of risk of loss of dissolved P. Our findings indicate that Olsen-P, which is measured routinely in Danish agricultural soils, may be a useful proxy for the P leaching potential of soils. However, we found no straight-forward correlation between leaching potential of the top soil layer (expressed as either degree of P saturation, Olsen-P or water extractable P) and the measured concentration of dissolved P in the tile-drain. This underlines that not only the source of P but also the P loss pathway must be taken into account when evaluating the risk of P loss.

  7. Numerical Simulation of Liquids Draining From a Tank Using OpenFOAM

    Science.gov (United States)

    Sakri, Fadhilah Mohd; Sukri Mat Ali, Mohamed; Zaki Shaikh Salim, Sheikh Ahmad; Muhamad, Sallehuddin

    2017-08-01

    Accurate simulation of liquids draining is a challenging task. It involves two phases flow, i.e. liquid and air. In this study draining a liquid from a cylindrical tank is numerically simulated using OpenFOAM. OpenFOAM is an open source CFD package and it becomes increasingly popular among the academician and also industries. Comparisons with theoretical and results from previous published data confirmed that OpenFOAM is able to simulate the liquids draining very well. This is done using the gas-liquid interface solver available in the standard library of OpenFOAM. Additionally, this study was also able to explain the physics flow of the draining tank.

  8. Closed suction drain with bulb

    Science.gov (United States)

    ... of gloves. Put a new bandage around the drain tube site. Use surgical tape to hold it down ... small amount of redness is normal). There is drainage from the skin around the tube site. There is more tenderness and swelling at ...

  9. Predicting artificailly drained areas by means of selective model ensemble

    DEFF Research Database (Denmark)

    Møller, Anders Bjørn; Beucher, Amélie; Iversen, Bo Vangsø

    . The approaches employed include decision trees, discriminant analysis, regression models, neural networks and support vector machines amongst others. Several models are trained with each method, using variously the original soil covariates and principal components of the covariates. With a large ensemble...... out since the mid-19th century, and it has been estimated that half of the cultivated area is artificially drained (Olesen, 2009). A number of machine learning approaches can be used to predict artificially drained areas in geographic space. However, instead of choosing the most accurate model....... The study aims firstly to train a large number of models to predict the extent of artificially drained areas using various machine learning approaches. Secondly, the study will develop a method for selecting the models, which give a good prediction of artificially drained areas, when used in conjunction...

  10. The Simple Urine Bag as Wound Drain Post-Craniotomy in a Low ...

    African Journals Online (AJOL)

    Methods: A 4-year prospective cohort study of the effectiveness, outcome with use and complications of the Uribag as post craniotomy wound drain in a consecutive cohort of neurosurgical patients. Data analyzed include the patients' brief demographics; the types of cranial surgery in which drain was used; the drain ...

  11. Frequency dependence and passive drains in fish-eye lenses

    Science.gov (United States)

    Quevedo-Teruel, O.; Mitchell-Thomas, R. C.; Hao, Y.

    2012-11-01

    The Maxwell fish eye lens has previously been reported as being capable of the much sought after phenomenon of subwavelength imaging. The inclusion of a drain in this system is considered crucial to the imaging ability, although its role is the topic of much debate. This paper provides a numerical investigation into a practical implementation of a drain in such systems, and analyzes the strong frequency dependence of both the Maxwell fish eye lens and an alternative, the Miñano lens. The imaging capability of these types of lens is questioned, and it is supported by simulations involving various configurations of drain arrays. Finally, a discussion of the near-field and evanescent wave contribution is given.

  12. Shearon Harris steam generator channel head drain line leakage

    International Nuclear Information System (INIS)

    Bauer, P.A.

    1992-01-01

    All three Shearon Harris steam generators were equipped with Inconel 600 drain penetrations inserted into clearance holes on the bottom center line of the plenums, roll expanded into the plenum shell, and seal welded to the stainless steel cladding. Eddy current inspections showed axial cracks in the drain lines of B and C generators, but not on the leaking A generator. The drain lines of the three generators were repaired by cutting off the pipe under the plenum, applying Inconel 600 cladding to the underside of the plenum by a temper bead process, spot facing the overlay cladding and welding a new Inconel 600 pipe coupling to the clad surface. 3 figs

  13. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  14. A mathematical model to optimize the drain phase in gravity-based peritoneal dialysis systems.

    Science.gov (United States)

    Akonur, Alp; Lo, Ying-Cheng; Cizman, Borut

    2010-01-01

    Use of patient-specific drain-phase parameters has previously been suggested to improve peritoneal dialysis (PD) adequacy. Improving management of the drain period may also help to minimize intraperitoneal volume (IPV). A typical gravity-based drain profile consists of a relatively constant initial fast-flow period, followed by a transition period and a decaying slow-flow period. That profile was modeled using the equation VD(t) = (V(D0) - Q(MAX) x t) xphi + (V(D0) x e(-alphat)) x (1 - phi), where V(D)(t) is the time-dependent dialysate volume; V(D0), the dialysate volume at the start of the drain; Q(MAX), the maximum drain flow rate; alpha, the exponential drain constant; and phi, the unit step function with respect to the flow transition. We simulated the effects of the assumed patient-specific maximum drain flow (Q(MAX)) and transition volume (psi), and the peritoneal volume percentage when transition occurs,for fixed device-specific drain parameters. Average patient transport parameters were assumed during 5-exchange therapy with 10 L of PD solution. Changes in therapy performance strongly depended on the drain parameters. Comparing 400 mL/85% with 200 mL/65% (Q(MAX/psi), drain time (7.5 min vs. 13.5 min) and IPV (2769 mL vs. 2355 mL) increased when the initial drain flow was low and the transition quick. Ultrafiltration and solute clearances remained relatively similar. Such differences were augmented up to a drain time of 22 minutes and an IPV of more than 3 L when Q(MAX) was 100 mL/min. The ability to model individual drain conditions together with water and solute transport may help to prevent patient discomfort with gravity-based PD. However, it is essential to note that practical difficulties such as displaced catheters and obstructed flow paths cause variability in drain characteristics even for the same patient, limiting the clinical applicability of this model.

  15. Drain Back Systems in Laboratory and in Practice

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2015-01-01

    in the collector loop to have a safe reliable operation. The components should also be designed and marked so that only one correct mounting option is possible, like forward and return pipes to/from the collector of slightly different sizes or color. Adapted installer education and training is a very important...... step to have success with drain back systems. Practices used in glycol systems may give serious failures. Key-words: Drain Back, Low Flow, Solar Combi System, ETC collectors....

  16. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple’s Operation

    Directory of Open Access Journals (Sweden)

    Sang Ho Bae

    2011-05-01

    Full Text Available A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  17. Perioperative lumbar drain utilization in transsphenoidal pituitary resection.

    Science.gov (United States)

    Alharbi, Shatha; Harsh, Griffith; Ajlan, Abdulrazag

    2018-01-01

    To evaluate lumbar drain (LD) efficacy in transnasal resection of pituitary macroadenomas in preventing postoperative cerebrospinal fluid (CSF) leak, technique safety, and effect on length of hospital stay. We conducted a retrospective data review of pituitary tumor patients in our institution who underwent surgery between December 2006 and January 2013. All patients were operated on for complete surgical resection of pituitary macroadenoma tumors. Patients were divided into 2 groups: group 1 received a preoperative drain, while LD was not preoperatively inserted in group 2. In cases of tumors with suprasellar extension with anticipation of high-flow leak, LD was inserted after the patient was intubated and in a lateral position. Lumbar drain was used for 48 hours, and the drain was removed if no leak was observed postoperatively. In documented postoperative CSF leak patients with no preoperative drain, the leak was treated by LD trial prior to surgical reconstruction. Cases in which leak occurred 6 months postoperatively were excluded. Our study population consisted of 186 patients, 99 women (53%) and 87 men (47%), with a mean age of 50.3+/-16.1 years. Complications occurred in 7 patients (13.7%) in group 1 versus 21 (15.5%) in group 2 (p=0.72). Postoperative CSF leak was observed in 1 patient (1.9%) in group 1 and 7 (5%) in group 2 (Fisher exact test=0.3). Length of hospital stay was a mean of 4.7+/-1.9 days in group 1 and a mean of 2.7+/-2.4 days in group 2 (pLD insertion is generally considered safe with a low risk of complications, it increases the length of hospitalization. Minor complications include headaches and patient discomfort.

  18. Effects of pond draining on biodiversity and water quality of farm ponds.

    Science.gov (United States)

    Usio, Nisikawa; Imada, Miho; Nakagawa, Megumi; Akasaka, Munemitsu; Takamura, Noriko

    2013-12-01

    Farm ponds have high conservation value because they contribute significantly to regional biodiversity and ecosystem services. In Japan pond draining is a traditional management method that is widely believed to improve water quality and eradicate invasive fish. In addition, fishing by means of pond draining has significant cultural value for local people, serving as a social event. However, there is a widespread belief that pond draining reduces freshwater biodiversity through the extirpation of aquatic animals, but scientific evaluation of the effectiveness of pond draining is lacking. We conducted a large-scale field study to evaluate the effects of pond draining on invasive animal control, water quality, and aquatic biodiversity relative to different pond-management practices, pond physicochemistry, and surrounding land use. The results of boosted regression-tree models and analyses of similarity showed that pond draining had little effect on invasive fish control, water quality, or aquatic biodiversity. Draining even facilitated the colonization of farm ponds by invasive red swamp crayfish (Procambarus clarkii), which in turn may have detrimental effects on the biodiversity and water quality of farm ponds. Our results highlight the need for reconsidering current pond management and developing management plans with respect to multifunctionality of such ponds. Efectos del Drenado de Estanques sobre la Biodiversidad y la Calidad del Agua en Estanques de Cultivo. © 2013 Society for Conservation Biology.

  19. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  20. Management of extensive surgical emphysema with subcutaneous drain: A case report

    Directory of Open Access Journals (Sweden)

    Quoc Tran

    Full Text Available Introduction: Subcutaneous emphysema (SE is a frequent and often self-limiting complication of tube thoracostomy or other cardiothoracic procedures. On rare occasions, severe and extensive surgical emphysema marked by palpable cutaneous tension, dysphagia, dysphonia, palpebral closure or associated with pneumoperitoneum, airway compromise, “tension phenomenon” and respiratory failure require treatment. Presentation of case: A 67 year old lady presented with a large spontaneous pneumothorax on the background of end-stage chronic obstructive pulmonary disease (COPD and newly diagnosed lung cancer, developed extensive surgical emphysema following insertion of a chest drain. Immediate improvement was observed after insertion of a large-bore, 26 French (Fr. intercostal catheter, subcutaneous drain which was maintained under low suction (−5 cm H2O for a further 24 h. Discussion: Several methods have been described in the literature for the treatment of extensive subcutaneous emphysema, including: emergency tracheostomy, multisite subcutaneous drainage, infraclavicular “blow holes” incisions and subcutaneous drains or simply increasing suction on an in situ chest drain. Here a large-bore, fenestrated, subcutaneous drain maintained on low negative pressure also provided the necessary decompression. Conclusion: In the absence of a comparative study to identify the most effective method to manage extensive subcutaneous emphysema, this case highlights an effective, simple and safe management option. Keywords: Pneumothorax, Subcutaneous emphysema, Drain, Low suction, Intercostal catheter, Case report

  1. A retrospective study of the use of active suction wound drains in dogs and cats.

    Science.gov (United States)

    Bristow, P C; Halfacree, Z J; Baines, S J

    2015-05-01

    To report indications for use and complications associated with commonly used closed active suction wound drains in a large number of clinical cases. Retrospective review of medical case records (from 2004 to 2010) for dogs and cats that had a closed active suction drain placed into a wound. Only the four most common drain types were included: Mini Redovac®, Redovac®, Jackson Pratt® and Wound Evac®. Two hundred and fifty-three drains were placed in 33 cats and 195 dogs. Mini Redovac drains were used most frequently in cats (76 · 5%) and Redovac drains in dogs (54 · 3%). The infection rate for clean surgeries in dogs was 15 · 6% (unattainable in cats). Major complications occurred in four dogs; minor complications occurred in 12 drains in cats (35 · 3%), and in 74 drains in dogs (33 · 8%). There was no statistically significant association between the type of drain and complication rate for either species. Although closed active suction drains can be used with low risk of major complications, they lead to a high rate of infection in clean surgeries in dogs. It is recommended that such drains are kept in place for the shortest time possible and that strict asepsis is adhered to both during placement and management. © 2015 British Small Animal Veterinary Association.

  2. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  3. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  4. Theory of Maxwell's fish eye with mutually interacting sources and drains

    Science.gov (United States)

    Leonhardt, Ulf; Sahebdivan, Sahar

    2015-11-01

    Maxwell's fish eye is predicted to image with a resolution not limited by the wavelength of light. However, interactions between sources and drains may ruin the subwavelength imaging capabilities of this and similar absolute optical instruments. Nevertheless, as we show in this paper, at resonance frequencies of the device, an array of drains may resolve a single source, or alternatively, a single drain may scan an array of sources, no matter how narrowly spaced they are. It seems that near-field information can be obtained from far-field distances.

  5. Improved simulation of poorly drained forests using Biome-BGC.

    Science.gov (United States)

    Bond-Lamberty, Ben; Gower, Stith T; Ahl, Douglas E

    2007-05-01

    Forested wetlands and peatlands are important in boreal and terrestrial biogeochemical cycling, but most general-purpose forest process models are designed and parameterized for upland systems. We describe changes made to Biome-BGC, an ecophysiological process model, that improve its ability to simulate poorly drained forests. Model changes allowed for: (1) lateral water inflow from a surrounding watershed, and variable surface and subsurface drainage; (2) adverse effects of anoxic soil on decomposition and nutrient mineralization; (3) closure of leaf stomata in flooded soils; and (4) growth of nonvascular plants (i.e., bryophytes). Bryophytes were treated as ectohydric broadleaf evergreen plants with zero stomatal conductance, whose cuticular conductance to CO(2) was dependent on plant water content. Individual model changes were parameterized with published data, and ecosystem-level model performance was assessed by comparing simulated output to field data from the northern BOREAS site in Manitoba, Canada. The simulation of the poorly drained forest model exhibited reduced decomposition and vascular plant growth (-90%) compared with that of the well-drained forest model; the integrated bryophyte photosynthetic response accorded well with published data. Simulated net primary production, biomass and soil carbon accumulation broadly agreed with field measurements, although simulated net primary production was higher than observed data in well-drained stands. Simulated net primary production in the poorly drained forest was most sensitive to oxygen restriction on soil processes, and secondarily to stomatal closure in flooded conditions. The modified Biome-BGC remains unable to simulate true wetlands that are subject to prolonged flooding, because it does not track organic soil formation, water table changes, soil redox potential or anaerobic processes.

  6. Management of Chest Drains: A National Survey on Surgeons‑in ...

    African Journals Online (AJOL)

    triangle of safety [Figure 1]. Just above a quarter of respondents (27.2%) always utilized different sizes of tubes for different pathologies and the same proportion of respondents always positioned the tip of the tube apically to drain pneumothorax and basally to drain pleural effusion. In contrast, 9.9% and 6.2% of respondents.

  7. Continuous 'Passive' Registration of Non-Point Contaminant Loads Via Agricultural Subsurface Drain Tubes

    Science.gov (United States)

    Rozemeijer, J.; Jansen, S.; de Jonge, H.; Lindblad Vendelboe, A.

    2014-12-01

    Considering their crucial role in water and solute transport, enhanced monitoring and modeling of agricultural subsurface tube drain systems is important for adequate water quality management. For example, previous work in lowland agricultural catchments has shown that subsurface tube drain effluent contributed up to 80% of the annual discharge and 90-92% of the annual NO3 loads from agricultural fields towards the surface water. However, existing monitoring techniques for flow and contaminant loads from tube drains are expensive and labor-intensive. Therefore, despite the unambiguous relevance of this transport route, tube drain monitoring data are scarce. The presented study aimed developing a cheap, simple, and robust method to monitor loads from tube drains. We are now ready to introduce the Flowcap that can be attached to the outlet of tube drains and is capable of registering total flow, contaminant loads, and flow-averaged concentrations. The Flowcap builds on the existing SorbiCells, a modern passive sampling technique that measures average concentrations over longer periods of time (days to months) for various substances. By mounting SorbiCells in our Flowcap, a flow-proportional part of the drain effluent is sampled from the main stream. Laboratory testing yielded good linear relations (R-squared of 0.98) between drainage flow rates and sampling rates. The Flowcap was tested in practice for measuring NO3 loads from two agricultural fields and one glasshouse in the Netherlands. The Flowcap registers contaminant loads from tube drains without any need for housing, electricity, or maintenance. This enables large-scale monitoring of non-point contaminant loads via tube drains, which would facilitate the improvement of contaminant transport models and would yield valuable information for the selection and evaluation of mitigation options to improve water quality.

  8. The stable stiffness triangle - drained sand during deformation cycles

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    2017-01-01

    Cyclic, drained sand stiffness was observed using the Danish triaxial appa- ratus. New, deformation dependant soil property (the stable stiffness triangle) was detected. Using the the stable stiffness triangle, secant stiffness of drained sand was plausible to predict (and control) even during ir...... findings can find application in off-shore, seismic and other engi- neering practice, or inspire new branches of research and modelling wherever dynamic, cyclic or transient loaded sand is encountered....

  9. Cold Vacuum Drying facility effluent drain system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) effluent drain system (EFS). The primary function of the EFS is to collect and transport fire suppression water discharged into a CVDF process bay to a retention basin located outside the facility. The EFS also provides confinement of spills that occur inside a process bay and allows non-contaminated water that drains to the process bay sumps to be collected until sampling and analysis are complete

  10. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    International Nuclear Information System (INIS)

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.; Joslyn, Cameron C.; Vazquez, Brandon J.; Venetz, Theodore J.; Garfield, John S.

    2014-01-01

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line

  11. Effect of an intervention in storm drains to prevent Aedes aegypti reproduction in Salvador, Brazil.

    Science.gov (United States)

    Souza, Raquel Lima; Mugabe, Vánio André; Paploski, Igor Adolfo Dexheimer; Rodrigues, Moreno S; Moreira, Patrícia Sousa Dos Santos; Nascimento, Leile Camila Jacob; Roundy, Christopher Michael; Weaver, Scott C; Reis, Mitermayer Galvão; Kitron, Uriel; Ribeiro, Guilherme Sousa

    2017-07-11

    Aedes aegypti, the principal vector for dengue, chikungunya and Zika viruses, is a synanthropic species that uses stagnant water to complete its reproductive cycle. In urban settings, rainfall water draining structures, such as storm drains, may retain water and serve as a larval development site for Aedes spp. reproduction. Herein, we describe the effect of a community-based intervention on preventing standing water accumulation in storm drains and their consequent infestation by adult and immature Ae. aegypti and other mosquitoes. Between April and May of 2016, local residents association of Salvador, Brazil, after being informed of water accumulation and Ae. aegypti infestation in the storm drains in their area, performed an intervention on 52 storm drains. The intervention consisted of placing concrete at the bottom of the storm drains to elevate their base to the level of the outflow tube, avoiding water accumulation, and placement of a metal mesh covering the outflow tube to avoid its clogging with debris. To determine the impact of the intervention, we compared the frequency at which the 52 storm drains contained water, as well as adult and immature mosquitoes using data from two surveys performed before and two surveys performed after the intervention. During the pre-intervention period, water accumulated in 48 (92.3%) of the storm drains, and immature Ae. aegypti were found in 11 (21.2%) and adults in 10 (19.2%). After the intervention, water accumulated in 5 (9.6%) of the storm drains (P Aedes mosquitoes (mainly Culex spp.) in the storm drains also decreased after the intervention. This study exemplifies how a simple intervention targeting storm drains can result in a major reduction of water retention, and, consequently, impact Ae. aegypti larval populations. Larger and multi-center evaluations are needed to confirm the potential of citywide structural modifications of storm drains to reduce Aedes spp. infestation level.

  12. Drain-Site Hernia Containing the Vermiform Appendix: Report of a Case

    Directory of Open Access Journals (Sweden)

    Markus Gass

    2013-01-01

    Full Text Available The herniated vermiform appendix has been described as content of every hernia orifice in the right lower quadrant. While the femoral and inguinal herniated vermiform appendix is frequent enough to result in an own designation, port-site or even drain-site hernias are less frequently described. We report the case of a 62-year-old woman who presented with right lower quadrant pain seven years after Roux-en-Y Cystojejunostomy for a pancreatic cyst. CT scan showed herniation of the vermiform appendix through a former drain-site. A diagnostic laparoscopy with appendectomy and direct closure of the abdominal wall defect combined with mesh reinforcement was performed. Despite the decreasing use of intraperitoneal drains over the recent years, a multitude of patients had intraperitoneal drainage in former times. These patients face nowadays the risk of drain-site hernias with sometimes even unexpected structures inside.

  13. Homogenization of one-dimensional draining through heterogeneous porous media including higher-order approximations

    Science.gov (United States)

    Anderson, Daniel M.; McLaughlin, Richard M.; Miller, Cass T.

    2018-02-01

    We examine a mathematical model of one-dimensional draining of a fluid through a periodically-layered porous medium. A porous medium, initially saturated with a fluid of a high density is assumed to drain out the bottom of the porous medium with a second lighter fluid replacing the draining fluid. We assume that the draining layer is sufficiently dense that the dynamics of the lighter fluid can be neglected with respect to the dynamics of the heavier draining fluid and that the height of the draining fluid, represented as a free boundary in the model, evolves in time. In this context, we neglect interfacial tension effects at the boundary between the two fluids. We show that this problem admits an exact solution. Our primary objective is to develop a homogenization theory in which we find not only leading-order, or effective, trends but also capture higher-order corrections to these effective draining rates. The approximate solution obtained by this homogenization theory is compared to the exact solution for two cases: (1) the permeability of the porous medium varies smoothly but rapidly and (2) the permeability varies as a piecewise constant function representing discrete layers of alternating high/low permeability. In both cases we are able to show that the corrections in the homogenization theory accurately predict the position of the free boundary moving through the porous medium.

  14. Origin of the water drained by the tunnel Graton

    International Nuclear Information System (INIS)

    Plata B, A.

    1992-12-01

    The research of the origin of the water drained by the Graton tunnel was attempted using isotope techniques. During the period of studies (April 1989-October 1992), four field work was executed to sample waters for chemistry, stable isotope and Tritium analysis, an to inject tracers and verify the possible infiltration from the Rimac and Blanco rivers to the tunnel. The results of the stable isotope analysis show that the water drained by the Graton tunnel comes from a basin around 300 meters above the average altitude of the basin where the Graton is located. The Tritium analysis show that the water is relatively modern. Using the model of total mixing, the residence times of the water drained at the km 0.5 and 2.5 are in the order to 45 years. The conductivities of the water of the tunnel is higher than the Rimac river ones because the influence of mine water. The chemical analysis of the water sampled at the downstream end of the tunnel, show that the conservative ions of the water kept almost constant during more than two years. The results of the work with artificial tracer show that there is no significant leakage from the Rimac and Blanco rivers to the Graton tunnel. So far, it can be concluded as a preliminary approach that the Graton tunnel drains relatively modern water originated in another basin. The hydrodynamics of the area of study seems to include a large storage on underground water in the system. The topography, geology and isotopic composition of the water samples, points to the upper Mantaro river basin as the possible source of part of the water drained by the Graton tunnel. (authors). 20 p. 2 figs., 7 ills., 4 tabs

  15. Optimization design for drain to nuclear power condenser

    International Nuclear Information System (INIS)

    Ding Jiapeng; Jiang Chengren

    2010-01-01

    Characters and varieties of drain to nuclear power condenser are discussed in this paper. Take the main steam system of a nuclear power as an example, normal and detailed optimization design are introduced, related expatiate are used as a reference for the drain of other systems. According to the characters of nuclear power instant operation, the influence and needed actions related with the optimization design are also analyzed. Based on the above research, the scheme has been carried out in a nuclear power station and safety for the condenser operation of the nuclear power has been improved largely. (authors)

  16. Charge plasma based source/drain engineered Schottky Barrier MOSFET: Ambipolar suppression and improvement of the RF performance

    Science.gov (United States)

    Kale, Sumit; Kondekar, Pravin N.

    2018-01-01

    This paper reports a novel device structure for charge plasma based Schottky Barrier (SB) MOSFET on ultrathin SOI to suppress the ambipolar leakage current and improvement of the radio frequency (RF) performance. In the proposed device, we employ dual material for the source and drain formation. Therefore, source/drain is divided into two parts as main source/drain and source/drain extension. Erbium silicide (ErSi1.7) is used as main source/drain material and Hafnium metal is used as source/drain extension material. The source extension induces the electron plasma in the ultrathin SOI body resulting reduction of SB width at the source side. Similarly, drain extension also induces the electron plasma at the drain side. This significantly increases the SB width due to increased depletion at the drain end. As a result, the ambipolar leakage current can be suppressed. In addition, drain extension also reduces the parasitic capacitances of the proposed device to improve the RF performance. The optimization of length and work function of metal used in the drain extension is performed to achieve improvement in device performance. Moreover, the proposed device makes fabrication simpler, requires low thermal budget and free from random dopant fluctuations.

  17. Estimating drain flow from measured water table depth in layered soils under free and controlled drainage

    Science.gov (United States)

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-01-01

    Long records of continuous drain flow are important for quantifying annual and seasonal changes in the subsurface drainage flow from drained agricultural land. Missing data due to equipment malfunction and other challenges have limited conclusions that can be made about annual flow and thus nutrient loads from field studies, including assessments of the effect of controlled drainage. Water table depth data may be available during gaps in flow data, providing a basis for filling missing drain flow data; therefore, the overall goal of this study was to examine the potential to estimate drain flow using water table observations. The objectives were to evaluate how the shape of the relationship between drain flow and water table height above drain varies depending on the soil hydraulic conductivity profile, to quantify how well the Hooghoudt equation represented the water table-drain flow relationship in five years of measured data at the Davis Purdue Agricultural Center (DPAC), and to determine the impact of controlled drainage on drain flow using the filled dataset. The shape of the drain flow-water table height relationship was found to depend on the selected hydraulic conductivity profile. Estimated drain flow using the Hooghoudt equation with measured water table height for both free draining and controlled periods compared well to observed flow with Nash-Sutcliffe Efficiency values above 0.7 and 0.8 for calibration and validation periods, respectively. Using this method, together with linear regression for the remaining gaps, a long-term drain flow record for a controlled drainage experiment at the DPAC was used to evaluate the impacts of controlled drainage on drain flow. In the controlled drainage sites, annual flow was 14-49% lower than free drainage.

  18. Estimation of local and regional components of drain - flow from an irrigated field

    International Nuclear Information System (INIS)

    Eching, S.O.; Hopmans, J.W.; Wallender, W.W.; Macyntyre, J.L.; Peters, D.

    1995-01-01

    The contribution of regional ground water and deep percolation from a furrow irrigated field to total drain flow was estimated using salt load analysis. It was found that 64% of the drain flow comes from regional ground water flow. The electrical conductivity of the drain water was highly correlated with the drain flow rate. From the field water balance with deep percolation as estimated from the salt load analysis, using yield function derived evapotranspiration, and measured changes in root zone water storage, it was shown that 14% of the crop evapotranspiration comes from ground water during the study period. 8 figs; 5 tabs; 15 refs ( Author )

  19. Strip-drains for in situ clean up of contaminated fine-grained soils

    International Nuclear Information System (INIS)

    Bowders, J.J.; Gabr, M.A.

    1995-01-01

    Methods for in situ remediation of contaminated soils, such as bioremediation, vacuum/air stripping and soil flushing have been found to be less effective under fine-grained soil conditions. To enhance the performance of these techniques, it was proposed that strip-drains or wick drains also known as prefabricated vertical (PV) drains be used. The research objective was to determine the feasibility of using PV drains to enhance the soil flushing process. Bench top and intermediate-scale laboratory experiments were conducted. An overview of the work, results and future considerations were presented. Results indicated that the technology is feasible. A preliminary model for the technology to be used in any field situation was developed. The model is currently being tested with data from physical experiments on both intermediate and field tests. 5 figs

  20. Reverse blocking characteristics and mechanisms in Schottky-drain AlGaN/GaN HEMT with a drain field plate and floating field plates

    International Nuclear Information System (INIS)

    Mao Wei; She Wei-Bo; Zhang Jin-Feng; Zheng Xue-Feng; Wang Chong; Hao Yue; Yang Cui

    2016-01-01

    In this paper, a novel AlGaN/GaN HEMT with a Schottky drain and a compound field plate (SD-CFP HEMT) is presented for the purpose of better reverse blocking capability. The compound field plate (CFP) consists of a drain field plate (DFP) and several floating field plates (FFPs). The physical mechanisms of the CFP to improve the reverse breakdown voltage and to modulate the distributions of channel electric field and potential are investigated by two-dimensional numerical simulations with Silvaco-ATLAS. Compared with the HEMT with a Schottky drain (SD HEMT) and the HEMT with a Schottky drain and a DFP (SD-FP HEMT), the superiorities of SD-CFP HEMT lie in the continuous improvement of the reverse breakdown voltage by increasing the number of FFPs and in the same fabrication procedure as the SD-FP HEMT. Two useful optimization laws for the SD-CFP HEMTs are found and extracted from simulation results. The relationship between the number of the FFPs and the reverse breakdown voltage as well as the FP efficiency in SD-CFP HEMTs are discussed. The results in this paper demonstrate a great potential of CFP for enhancing the reverse blocking ability in AlGaN/GaN HEMT and may be of great value and significance in the design and actual manufacture of SD-CFP HEMTs. (paper)

  1. Thailand and brain drain

    OpenAIRE

    Terry Commins

    2009-01-01

    Brain drain has been the subject of research since the 1960s. This research has been hampered by a lack of accurate data from both source and receiving countries on migration and on the losses and gains to developing economies of skilled migration. However, despite these handicaps, research has been able to clearly show that trends are changing and the effect this is having is usually quite different for individual source countries.Thailand, as a developing economy, could be regarded as a sou...

  2. The European Politics of Brain Drain

    DEFF Research Database (Denmark)

    Hasselbalch, Jacob

    This qualitative multi-method studymaps the politics of brain drain at the level of the European Union and follows the evolution of the issue over the last four parliamentary periods. By utilizing a novel combination of interviews with a content and network analysis of parliamentary questions...

  3. An economic perspective on Malawi's medical "brain drain"

    Directory of Open Access Journals (Sweden)

    Mohiddin Abdu

    2006-12-01

    Full Text Available Abstract Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production" of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a

  4. An economic perspective on Malawi's medical "brain drain"

    Science.gov (United States)

    Record, Richard; Mohiddin, Abdu

    2006-01-01

    Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production") of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance) to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a closer look at the evidence

  5. Reduction in wick drain effectiveness with spacing for Utah silts and clays.

    Science.gov (United States)

    2012-04-01

    Although decreasing the spacing of vertical drains usually decreases the time for consolidation, previous field tests have shown that there is a critical drain spacing for which tighter spacing does not decrease the time for consolidation. This...

  6. Processing method of radioactive cleaning drain

    International Nuclear Information System (INIS)

    Otsuka, Shigemitsu; Murakami, Tadashi; Kitao, Hideo

    1998-01-01

    Upon processing of radioactive cleaning drains, contained Co-60 is removed by a selectively adsorbing adsorbent. In addition, after removing suspended materials by a filtering device, Co-60 as predominant nuclides in the drain is selectively adsorbed. The concentration of objective Co-60 is in the order of 0.1 Bq/cc, and non-radioactive metal ions such as Na + ions are present in the order of ppm in addition to Co-60. A granular adsorbent for selectively adsorbing Co-60 is oxine-added activated carbon, and has a grain size of from 20 to 48 mesh. The granular adsorbent is used while being filled in an adsorbing tower. Since a relatively simple device comprising the filtering device and the adsorbing tower in combination is provided, the reduction of the construction cost can be expected. In addition, since no filtering aid is used in the filtering device, the amount of secondary wastes is small. (N.H.)

  7. Autologous transfusion of drain contents in elective primary knee arthroplasty: its value and relevance.

    Science.gov (United States)

    Singh, Vinay Kumar; Singh, Pankaj Kumar; Javed, Sadaf; Kumar, Kuldeep; Tomar, Juhi

    2011-07-01

    Total knee arthroplasty is associated with significant post-operative blood loss often necessitating blood transfusions. Blood transfusions may be associated with transfusion reactions and may transmit human immunodeficiency virus, hepatitis C virus and hepatitis B virus, with devastating consequences. After total knee arthroplasty, transfusion of the contents of an autologous drain is becoming common practice. The aim of our study was to look at the effectiveness of these drains in elective primary total knee arthroplasty. A prospective study was conducted including 70 non-randomised patients. A normal suction drain was used in 35 patients (group A), whereas in the other 35 patients, a CellTrans™ drain was used (group B). All the operations were performed by four surgeons using a tourniquet with a medial parapatellar approach. Pre- and post-operative haemoglobin concentrations were recorded in both groups. A Student's t-test was applied to determine the statistical significance of the data collected. The average fall in post-operative haemoglobin was 3.66 g/dL (SD 1.46; range, 0.6-7.0) among patients in whom the simple drain was used (group A) and 2.29 g/dL (SD 0.92; range, 0.6-5.9) among those in whom the CellTrans™ drain was used (group B) (p<0.0001). Twenty-five units of allogeneic blood were required in group A compared to four units in group B. The rate of transfusion was 5.7% (2 patients) in the group in which CellTrans™ drain was used and 25.7% (9 patients) in the group in which a simple suction drain was used. Total knee arthroplasty is associated with significant post-operative blood loss despite best operative technique. Autologous reinfusion of the contents of a CellTrans™ drain significantly reduces the rate of post-operative blood transfusion. This study indicates that the use of an autologous drain could be recommended as routine practice in primary total knee arthroplasty.

  8. Is a drain tube necessary for minimally invasive lumbar spine fusion surgery?

    Science.gov (United States)

    Hung, Pei-I; Chang, Ming-Chau; Chou, Po-Hsin; Lin, Hsi-Hsien; Wang, Shih-Tien; Liu, Chien-Lin

    2017-03-01

    This study aimed to evaluate if closed suction wound drainage is necessary in minimally invasive surgery of transforaminal lumbar interbody fusion (MIS TLIF). This is a prospective randomized clinical study. Fifty-six patients who underwent MIS TLIF were randomly divided into groups A (with a closed suction wound drainage) and B (without tube drainage). Surgical duration, intraoperative blood loss, timing of ambulation, length of hospital stay and complications were recorded. Patients were followed up for an average of 25.3 months. Clinical outcome was assessed using the Oswestry disability index and visual analogue scale (VAS). Fusion rate was classified with the Bridwell grading system, based on plain radiograph. Both groups had similar patient demographics. The use of drains had no significant influence on perioperative parameters including operative time, estimated blood loss, length of stay and complications. Patients in group B started ambulation 1 day earlier than patients in group A (p drain tube can lead to pain, anxiety and discomfort during the postoperative period. We conclude that drain tubes are not necessary for MIS TLIF. Patients without drains had the benefit of earlier ambulation than those with drains.

  9. Nurses’ knowledge of care of chest drain: A survey in a Nigerian semiurban university hospital

    Science.gov (United States)

    Kesieme, Emeka Blessius; Essu, Ifeanyichukwu Stanley; Arekhandia, Bruno Jeneru; Welcker, Katrin; Prisadov, Georgi

    2016-01-01

    Background/Objective: Inefficient nursing care of chest drains may associated with unacceptable and sometimes life-threatening complications. This report aims to ascertain the level of knowledge of care of chest drains among nurses working in wards in a teaching hospital in Nigeria. Methods: A cross-sectional study among nurses at teaching hospital using pretested self-administered questionnaires. Results: The majority were respondents aged between 31 and 40 years (45.4%) and those who have nursing experience between 6 and 10 years. Only 37 respondents (26.2%) had a good knowledge of nursing care of chest drains. Knowledge was relatively higher among nurses who cared for chest drains daily, nurses who have a work experience of 0.05). Performance was poor on the questions on position of drainage system were not statistically significant with relationship to waist level while mobilizing the patient, application of suction to chest drains, daily changing of dressing over chest drain insertion site, milking of tubes and drainage system with dependent loop. Conclusion: The knowledge of care of chest drains among nurses is poor, especially in the key post procedural care. There is an urgent need to train them so as to improve the nursing care of patients managed with chest drains. PMID:26857934

  10. Drainage of shallow peat harvesting areas with pipe drains; Madaltuneen turvetuotantokentaen kuivatustutkimus

    Energy Technology Data Exchange (ETDEWEB)

    Klemetti, V. [Vapo Oy, Jyvaeskylae (Finland)

    1997-12-01

    This study aims to develop pipe draining techniques in peat harvesting areas, which have been in active use so long time that the remaining peat layer is about one meter thick. The method should be technically and economically feasible as well as environmentally acceptable. Special attention is paid to pipe installation techniques, drain spacing and impacts on watercourses, which receive the drainage waters. After pipe installation the area was monitored by measuring pipe runoffs, water tables, moisture content of peat and quality of drain water. These are the results of second year. (orig.)

  11. Draining Collars and Lenses in Liquid-Lined Vertical Tubes.

    Science.gov (United States)

    Jensen

    2000-01-01

    The speed at which an annular liquid collar drains under gravity g in a vertical tube of radius a, when the tube has an otherwise thin viscous liquid lining on its interior, is determined by a balance between the collar's weight and viscous shear stresses confined to narrow regions in the neighborhood of the collar's effective contact lines. Whether a collar grows or shrinks in volume as it drains depends on the modified Bond number B=rho g a(2)/(sigmaepsilon), where rho is the fluid density, sigma is its surface tension, and epsilona is the thickness of the thin film immediately ahead of the collar. Asymptotic methods are used here to determine the following nonlinear stability criteria for an individual collar, valid in the limit of small epsilon. For 0draining collars grow in volume and, in sufficiently long tubes, ultimately "snap off" to form stable lenses. For 0.5960drain, so that any lens ultimately ruptures, unless stabilizing intermolecular forces allow the formation of a lamella supported by a macroscopic Plateau border. If surfactant immobilizes the liquid's free surface, these critical values of B are reduced by a factor of 2 but the distance a collar must travel before it snaps off is unchanged. Gravitationally driven snap off is therefore most likely to occur in long tubes with radii substantially less than the capillary lengthscale sigma/rhog)(1/2). Copyright 2000 Academic Press.

  12. Brain drain in globalization A general equilibrium analysis from the sending countries’ perspective

    OpenAIRE

    Luca MARCHIORI; I-Ling SHEN; Frederic DOCQUIER

    2009-01-01

    The paper assesses the global effects of brain drain on developing economies and quantifies the relative sizes of various static and dynamic impacts. By constructing a unified generic framework characterized by overlapping generations dynamics and calibrated to real data, this study incorporates many direct impacts of brain drain whose interactions, along with other indirect effects, are endogenously and dynamically generated. Our findings suggest that the short-run impact of brain drain on r...

  13. Restructuring brain drain: strengthening governance and financing for health worker migration.

    Science.gov (United States)

    Mackey, Tim K; Liang, Bryan A

    2013-01-15

    Health worker migration from resource-poor countries to developed countries, also known as ''brain drain'', represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed.

  14. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    Directory of Open Access Journals (Sweden)

    Gonzalo García-Ros

    2018-02-01

    Full Text Available The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018, a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulation Program with Integrated Circuit Emphasis (Ngspice has been used as a numerical tool while the Matrix Laboratory (MATLAB code was used to program and create an interface with the user through interactive screens. In this way, SICOMED_2018 is presented as an easy-to-use and intuitive program, with a simple graphical interface that allows the user to enter all the soil properties and geometry of the problem without having to resort to a complex software package that requires programming. Illustrative applications describe both the versatility of the program and the reliability of its numerical solutions.

  15. Brain drain from developing countries: how can brain drain be converted into wisdom gain?

    OpenAIRE

    Dodani, Sunita; LaPorte, Ronald E

    2005-01-01

    Brain drain is defined as the migration of health personnel in search of the better standard of living and quality of life, higher salaries, access to advanced technology and more stable political conditions in different places worldwide. This migration of health professionals for better opportunities, both within countries and across international borders, is of growing concern worldwide because of its impact on health systems in developing countries. Why do talented people leave their count...

  16. In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?

    Science.gov (United States)

    Johnson, Charles H N; Lang, Sommer A; Bilal, Haris; Rammohan, Kandadai S

    2014-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?'. Altogether more than 200 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Subcutaneous emphysema is usually a benign, self-limiting condition only requiring conservative management. Interventions are useful in the context of severe patient discomfort, respiratory distress or persistent air leak. In the absence of any comparative study, it is not possible to choose definitively between infraclavicular incisions, drain insertion and increasing suction on an in situ drain as the best method for managing severe subcutaneous emphysema. All the three techniques described have been shown to provide effective relief. Increasing suction on a chest tube already in situ provided rapid relief in patients developing SE following pulmonary resection. A retrospective study showed resolution in 66%, increasing to 98% in those who underwent video-assisted thoracic surgery with identification and closure of the leak. Insertion of a drain into the subcutaneous tissue also provided rapid sustained relief. Several studies aided drainage by using regular compressive massage. Infraclavicular incisions were also shown to provide rapid relief, but were noted to be more invasive and carried the potential for cosmetic defect. No major complications were illustrated. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Outcome in Chronic Subdural Hematoma After Subdural vs. Subgaleal Drain.

    Science.gov (United States)

    Ishfaq, Asim

    2017-07-01

    To compare the outcome after surgery for chronic subdural hematoma when the drain is placed in subdural space or subgaleal space. Quasi experimental study. Combined Military Hospital, Lahore, from July 2015 to June 2016. Patients with chronic subdural hematoma of both genders and age, ranging between 55 to 85 years, were included. Patients on antiplatelet/anticoagulant therapy and acute on chronic subdural hematoma were excluded. Patients were divided in two equal groups each depending on whether drain was placed in subgaleal space (Group 1), and subdual space (Group 2), (n=31 patients each). Patients were positioned flat in bed after surgery. Clinical and radiological parameters and clinical outcome were compared between the two groups. Statistical test with significance of p hematoma was 15 ±6.5 mm. Patients with subdural drain placement had more complications such as pneumocephalus 11 (35.4%) vs. 6 (19.3%), and intracerebral hemorrhage 4 (12.9%) vs. 2 (6.4%). Clinical outcome was good in both groups 27 (87%) in Group 1 and 28 (90%) in Group 2. Patients of both groups had good outcome after surgery. Complications like pneumocephalus and intracerebral hemorrhage were more common in subdural location of drain, though not reaching statistically significance level to favor one technique over another.

  18. Prefabricated vertical drains, vol. I : engineering guidelines.

    Science.gov (United States)

    1986-09-01

    This volume presents procedures and guidelines applicable to the design and instal : tion of prefabricated vertical drains to accelerate consolidation of soils. The : contents represent the Consultant's interpretation of the state-of-the-art as of : ...

  19. The effect of drains on the alkalinity of agricultural soils

    International Nuclear Information System (INIS)

    Iqbal, M.A.; Butt, T.; Anwar-ul-Haque; Haroon, M.; Haq, I.U.

    2009-01-01

    The purpose of the study was to observe the effect of industrial and domestic drains on the nearby agricultural areas which are either irrigated or not by the waste water but are close to drains. For this purpose 48 soil samples were collected from the selected areas of Faisalabad and were analyzed for alkali metals like Na/sup +/, K/sup +/, Li/sup +/ and some alkaline earth metals like Ba/sup 2+/> Mg/sup 3+/> Na/sup +/> K/sup +/> Li/sup +/ the levels of Ba/sup +2/ and K/sup +/ were found higher than permissible levels in almost all the soil samples. It was also concluded that the agricultural areas near the industrial drain which are either irrigated or not by the industrial waste water are found highly contaminated with mobile alkali metals (K, Na etc.) and higher values of percentage salinity. (author)

  20. An analytical drain current model for symmetric double-gate MOSFETs

    Science.gov (United States)

    Yu, Fei; Huang, Gongyi; Lin, Wei; Xu, Chuanzhong

    2018-04-01

    An analytical surface-potential-based drain current model of symmetric double-gate (sDG) MOSFETs is described as a SPICE compatible model in this paper. The continuous surface and central potentials from the accumulation to the strong inversion regions are solved from the 1-D Poisson's equation in sDG MOSFETs. Furthermore, the drain current is derived from the charge sheet model as a function of the surface potential. Over a wide range of terminal voltages, doping concentrations, and device geometries, the surface potential calculation scheme and drain current model are verified by solving the 1-D Poisson's equation based on the least square method and using the Silvaco Atlas simulation results and experimental data, respectively. Such a model can be adopted as a useful platform to develop the circuit simulator and provide the clear understanding of sDG MOSFET device physics.

  1. Postoperative use of drain in thyroid lobectomy – a randomized clinical trial conducted at Civil Hospital, Karachi, Pakistan

    Directory of Open Access Journals (Sweden)

    Memon Zahid

    2012-09-01

    Full Text Available Abstract Background Thyroidectomy is a common surgical procedure, after which drains are placed routinely. This study aims to assess the benefits of placing postoperative drains, its complications and affects on postoperative stay, in thyroid lobectomy. Methodology Randomized Clinical Trial of 60 goitre patients undergoing lobectomy was conducted at Civil Hospital Karachi, during July’11-December’11. Patients were randomly assigned into drain and non drain groups. Patient demographics, labs and complications were noted. Ultrasound of neck was performed on both groups. For drain group, the amount of fluid present in the surgical bed and redivac drain was added to calculate fluid collection while in non drain group it was calculated by ultrasound of neck on first and second post-op days. Data was entered and analyzed on SPSS v16 using Independent T tests. Result The mean total drain output for 2 days in non-drain group was significantly lower 10.67 (±9.072 ml while in drain group was 30.97 (±42.812 ml (p = 0.014. The mean postoperative stay of drain group (79.2 ±15.63 hours was significantly higher, as compared to mean postoperative stay of non drain group (50.4 ±7.32 hours. Mean Visual Analogue Score (VAS for pain day 1 (6.2 ±0.997 and day 2 (4.17 ±0.95 in drain group were significantly higher compared to day 1 (2.6 ±1.163 and day 2 (1.3 ±0.877 of non drain group. From drain group, 2 patients complained of stridor, dyspnea on Day 1 which subsided by Day 2 and 1 case of voice change, with no such complains in non drain group. No patients from both groups developed seroma, wound infection or hematoma. Conclusion In uncomplicated surgeries especially for lobectomy, use of drain can be omitted.

  2. Reverse blocking characteristics and mechanisms in Schottky-drain AlGaN/GaN HEMT with a drain field plate and floating field plates

    Science.gov (United States)

    Wei, Mao; Wei-Bo, She; Cui, Yang; Jin-Feng, Zhang; Xue-Feng, Zheng; Chong, Wang; Yue, Hao

    2016-01-01

    In this paper, a novel AlGaN/GaN HEMT with a Schottky drain and a compound field plate (SD-CFP HEMT) is presented for the purpose of better reverse blocking capability. The compound field plate (CFP) consists of a drain field plate (DFP) and several floating field plates (FFPs). The physical mechanisms of the CFP to improve the reverse breakdown voltage and to modulate the distributions of channel electric field and potential are investigated by two-dimensional numerical simulations with Silvaco-ATLAS. Compared with the HEMT with a Schottky drain (SD HEMT) and the HEMT with a Schottky drain and a DFP (SD-FP HEMT), the superiorities of SD-CFP HEMT lie in the continuous improvement of the reverse breakdown voltage by increasing the number of FFPs and in the same fabrication procedure as the SD-FP HEMT. Two useful optimization laws for the SD-CFP HEMTs are found and extracted from simulation results. The relationship between the number of the FFPs and the reverse breakdown voltage as well as the FP efficiency in SD-CFP HEMTs are discussed. The results in this paper demonstrate a great potential of CFP for enhancing the reverse blocking ability in AlGaN/GaN HEMT and may be of great value and significance in the design and actual manufacture of SD-CFP HEMTs. Project supported by the National Natural Science Foundation of China (Grant Nos. 61204085, 61334002, 61306017, 61474091, 61574112, and 61574110).

  3. Effects of Drains on Pain, Comfort and Anxiety in Patients Undergone Surgery

    Directory of Open Access Journals (Sweden)

    Ummu Yildiz Findik

    2013-01-01

    Full Text Available Backround: Surgical drains negatively affect patients’ comfort, cause anxiety along with pain, as they are used to promote healing after surgery.Purpose: This study aimed to determine pain, comfort and anxiety levels of patients with drains postoperatively.Methodology: Research was performed with 192 patients undergone abdominal, neck, breast and open heart surgery and had surgical and underwater chest drains at the postoperative period. Patient Information Form, Numerical Pain Scale, General Comfort Questionnaire and Trait Anxiety Scale was used for collection of data. In evaluating the data, we used the t-test, variance and correlation analysis, mean, percentage and frequency.Results: The patients’ mean score of pain was 4.67±2.93, comfort was 2.75±0.29 and anxiety was 39.31±9.21. It was found statistically significant that the comfort level decreases as the pain level increases and that the patients undergone open heart surgery and with underwater chest drains have higher pain levels. It was found statistically significant that, comfort level in patients undergone abdominal or cardiac surgery is lower than patients undergone breast or neck surgery, and that the comfort level decreases as the duration of drains increases. The increasing state anxiety while pain increases and comfort decreases was found statistically significant.Conclusions: Surgeries and drains applied after these procedures decrease the comfort level of the patients as increases the pain level. Also, pain and discomfort increase the patients’ anxiety. Nurses who providing care to these patients are suggested to improve measures about pain and anxiety reduction for maintaining of comfort.

  4. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report.

    Science.gov (United States)

    Lai, Peng-Sheng; Lo, Chiao; Lin, Long-Wei; Lee, Po-Chu

    2010-05-21

    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  5. An analytical drain current model for symmetric double-gate MOSFETs

    Directory of Open Access Journals (Sweden)

    Fei Yu

    2018-04-01

    Full Text Available An analytical surface-potential-based drain current model of symmetric double-gate (sDG MOSFETs is described as a SPICE compatible model in this paper. The continuous surface and central potentials from the accumulation to the strong inversion regions are solved from the 1-D Poisson’s equation in sDG MOSFETs. Furthermore, the drain current is derived from the charge sheet model as a function of the surface potential. Over a wide range of terminal voltages, doping concentrations, and device geometries, the surface potential calculation scheme and drain current model are verified by solving the 1-D Poisson’s equation based on the least square method and using the Silvaco Atlas simulation results and experimental data, respectively. Such a model can be adopted as a useful platform to develop the circuit simulator and provide the clear understanding of sDG MOSFET device physics.

  6. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    Directory of Open Access Journals (Sweden)

    Lin Long-Wei

    2010-05-01

    Full Text Available Abstract Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  7. Method of bilateral pleural drainage by single Blake drain after esophagectomy.

    Science.gov (United States)

    Niwa, Yukiko; Koike, Masahiko; Oya, Hisaharu; Iwata, Naoki; Kobayashi, Daisuke; Kanda, Mitsuro; Tanaka, Chie; Yamada, Suguru; Fujii, Tsutomu; Nakayama, Goro; Sugimoto, Hiroyuki; Nomoto, Shuji; Fujiwara, Michitaka; Kodera, Yasuhiro

    2015-03-01

    Clinicians often encounter left pleural effusion after esophagectomy, which sometimes necessitates thoracentesis. We have introduced a new drainage method, bilateral pleural drainage by single Blake drain (BDSD), which we have been using since April 2013. This study aims to evaluate the performance of the BDSD. The BDSD method employs a 15-F Blake drain inserted from the right thoracic cavity to the left thoracic cavity across the posterior mediastinum. The conventional drain (CD) group consisted of 50 patients with a 19-F Blake drain placed in the right thoracic cavity during the period from April 2012 to March 2013. The BDSD group consisted of 54 patients treated from April 2013 to June 2014. The amount of total drainage in the BDSD group was significantly higher than that in the CD group (P pleural effusion and left lower lobe atelectasis in the BDSD group were significantly lower than those in the CD group (P pleural effusion necessitating thoracentesis drainage in the BDSD group. Compared with the conventional method, BDSD was able to evacuate bilateral pleural effusion more effectively, and the incidences of left pleural effusion and left atelectasis were lower. This method is therefore clinically useful after esophagectomy.

  8. State waste discharge permit application, 200-E chemical drain field

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field.

  9. State waste discharge permit application, 200-E chemical drain field

    International Nuclear Information System (INIS)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field

  10. Drainage of shallow peat harvesting areas with pipe drains; Mataloituneen turvekentaen kuivatus putkisalaojilla

    Energy Technology Data Exchange (ETDEWEB)

    Klemetti, V.; Saenkiaho, K. [Vapo Oy, Jyvaeskylae (Finland); Rautiainen, O. [Ojamarkkinointi Oy, Heinola (Finland)

    1996-12-31

    This study aims to develop pipe draining technics in peat harvesting areas, which have been in active use so long time that the remaining peat layer is about one meter thick. The method should be technically and economically feasible as well as environmentally acceptable. Special attention is paid to pipe installation techniques, drain spacing and impacts on watercourses, which receive the drainage waters. After pipe installation the area is monitored by measuring pipe runoffs, water tables, moisture content of peat and quality of drain water

  11. Pesticide transport to tile-drained fields in SWAT model – macropore flow and sediment

    DEFF Research Database (Denmark)

    Lu, Shenglan; Trolle, Dennis; Blicher-Mathiesen, Gitte

    2015-01-01

    Tool (SWAT) to simulate transport of both mobile (e.g. Bentazon) and strongly sorbed (e.g. Diuron) pesticides in tile drains. Macropore flow is initiated when soil water content exceeds a threshold and rainfall intensity exceeds infiltration capacity. The amount of macropore flow is calculated...... to macropore sediment transport. Simulated tile drain discharge, sediment and pesticide loads are calibrated against data from intensively monitored tile-drained fields and streams in Denmark....

  12. Sampling and analysis plan (SAP) for WESF drains and TK-100 sump

    International Nuclear Information System (INIS)

    Simmons, F.M.

    1998-01-01

    The intent of this project is to determine whether the Waste Encapsulation and Storage Facility (WESF) floor drain piping and the TK-100 sump are free from contamination. TK-100 is currently used as a catch tank to transfer low level liquid waste from WESF to Tank Farms via B Plant. This system is being modified as part of the WESF decoupling since B Plant is being deactivated. As a result of the 1,1,1-trichloroethane (TCA) discovery in TK-100, the associated WESF floor drains and the pit sump need to be sampled. Breakdown constituents have been reviewed and found to be non-hazardous. There are 29 floor drains that tie into a common header leading into the tank. To prevent high exposure during sampling of the drains, TK-100 will be removed into the B Plant canyon and a new tank will be placed in the pit before any floor drain samples are taken. The sump will be sampled prior to TK-100 removal. A sample of the sludge and any liquid in the sump will be taken and analyzed for TCA and polychlorinated biphenyl (PCB). After the sump has been sampled, the vault floor will be flushed. The flush will be transferred from the sump into TK-100. TK-100 will be moved into B Plant. The vault will then be cleaned of debris and visually inspected. If there is no visual indication of TCA or PCB staining, the vault will be painted and a new tank installed. If there is an indication of TCA or PCB from laboratory analysis or staining, further negotiations will be required to determine a path forward. A total of 8 sets of three 40ml samples will be required for all of the floor drains and sump. The sump set will include one 125ml solid sample. The only analysis required will be for TCA in liquids. PCBs will be checked in sump solids only. The Sampling and Analysis Plan (SAP) is written to provide direction for the sampling and analytical activities of the 29 WESF floor drains and the TK-100 sump. The intent of this plan is to define the responsibilities of the various organizations

  13. Safety of peritoneal and pleural drain placement in pediatric stem cell transplant recipients with severe veno-occlusive disease.

    Science.gov (United States)

    Madenci, Arin L; Stetson, Alyssa; Weldon, Christopher B; Lehmann, Leslie E

    2016-08-01

    Hepatic VOD (veno-occlusive disease) is a serious complication of HSCT (hematopoietic stem cell transplantation) and has historically been associated with high mortality. This obstruction to hepatic flow often results in fluid collections in the peritoneal and pleural cavities. Catheter placement to drain ascites or pleural fluid may reduce intra-abdominal hypertension and/or improve respiratory parameters. The safety of these interventions among critically ill, immunocompromised children is unknown. Among 32 HSCT recipients (2000-2012) with severe VOD, we assessed the primary outcome of procedural complication from peritoneal drain placement. Twenty-four (75%) patients underwent peritoneal drain placement. No patient sustained visceral perforation or hemorrhage with drain placement. Overall mortality was 47% (n = 15). The procedure was not associated with increased overall mortality (p > 0.99). Eight (25%) peritoneal drains required replacement for malfunction. Of 24 patients with peritoneal drains, one (4%) patient had a positive culture from ascitic fluid. Eight (25%) patients underwent pleural drain placement. No pleural drain-related procedural complication or infection occurred. Four (50%) of the eight patients with pleural drains had de-escalation in oxygen requirement at drain removal, compared to time of placement. In this study, peritoneal and pleural drains were safe interventions for children with severe VOD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. 76 FR 62605 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Science.gov (United States)

    2011-10-11

    ... the VGB Act defines an ``unblockable drain'' as ``a drain of any size and shape that a human body... intentions. They claim that for this reason, backup systems are necessary, and a swimming pool or spa with a... of an ``unblockable drain,'' at 16 CFR 1450.2(b) and believe it was in error. Regardless of the size...

  15. Interaction of the Bored Sand and Gravel Drain Pile with the Surrounding Compacted Loam Soil and Foundation Raft Taking into Account Rheological Properties of the Loam Soil and Non-Linear Properties of the Drain Pile

    Science.gov (United States)

    Ter-Martirosyan, Z. G.; Ter-Martirosyan, A. Z.; Anzhelo, G. O.; Buslov, A. S.

    2018-01-01

    The task of the interaction of the sand and gravel drain pile with the surrounding loam soil after its preliminary deep compaction and formation of the composite ground cylinder from the drain pile and surrounding compacted loam soil (cells) is considered in the article. It is seen that the subsidence and carrying capacity of such cell considerably depends on physical and mechanical properties of the compacted drain piles and surrounding loam soil as well as their diameter and intercellular distance. The strain-stress state of the cell is considered not taking into account its component elements, but taking into account linear and elastic-plastic properties of the drain pile and creep flow of the surrounding loam soil. It is stated that depending on these properties the distribution and redistribution of the load on a cell takes place from the foundation raft between the drain pile and surrounding soil. Based on the results of task solving the formulas and charts are given demonstrating the ratio of the load between the drain pile and surrounding loam soil in time.

  16. Modelling Technique for the Assessment of the Sub-Soil Drain for Groundwater Seepage Remediation

    Directory of Open Access Journals (Sweden)

    Tajul Baharuddin Mohamad Faizal

    2017-01-01

    Full Text Available Groundwater simulation technique was carried out for examining the performance of sub-soil drain at problematic site area. Subsoil drain was proposed as one of solution for groundwater seepage occurred at the slope face by reducing groundwater table at Taman Botani Park Kuala Lumpur. The simulation technique used Modular Three-Dimensional Finite Difference Groundwater Flow (MODFLOW software. In transient conditions, the results of simulation showed that heads increases surpass 1 to 2 m from the elevation level of the slope area that caused groundwater seepage on slope face. This study attempt to decrease the heads increase surpass by using different sub-soil drain size in simulation technique. The sub-soil drain capable to decline the heads ranges of 1 to 2 m.

  17. Characterizing subsurface water flow to artificial drain lines using fiber-optic distributed temperature sensing

    Science.gov (United States)

    Shults, D.; Brooks, E. S.; Heinse, R.; Keller, C. K.

    2017-12-01

    Over the last several years growers have experienced increasingly wet spring conditions in the Palouse Region located in North Idaho, Eastern Washington and Eastern Oregon. As a result more artificial drain lines are being installed so growers can access their fields earlier in the growing season. Additionally there has been increasing adoption of no-tillage practices among growers in order minimize erosion and runoff in the region. There is a growing body of evidence that suggests long-term no-tillage may lead to the establishment of large macropore networks through increased earthworm activity and the preservation of root channels. These macropore networks, in conjunctions with the presence of artificial drains lines, may create connected preferential flow paths from agricultural fields to receiving streams. This connectivity of flow paths from agricultural fields to receiving water bodies may increase the loading of nutrients and agricultural chemicals as some flow paths may largely bypass soil matrix interaction where materials can be sequestered. Our primary objective for this study was to characterize subsurface flow to two artificial drain lines, one under conventional tillage and the other under no-tillage, using distributed temperature sensing (DTS) technology. During the study (November 2016-April 2017) the near surface soil-water temperature was consistently colder than that of deeper depths. Temperature was thus used as a tracer as snow melt and soil-water moved from the near surface to the drain lines during snowmelt and precipitation events. The spatial and temporal variability of the temperature along the artificial drain line under no-tillage practices was found to be greater than that of the conventional tilled field. It is hypothesized that preferential flow paths are responsible for the increased variability of temperature seen in the drain line under long term no-till management. The temperature along the conventional till drain line showed a

  18. Evapotranspiration from drained wetlands: drivers, modeling, storage functions, and restoration implications

    Science.gov (United States)

    Shukla, S.; Wu, C. L.; Shrestha, N.

    2017-12-01

    Abstract Evapotranspiration (ET) is a major component of wetland and watershed water budgets. The effect of wetland drainage on ET is not well understood. We tested whether the current understanding of insignificant effect of drainage on ET in the temperate region wetlands applies to those in the sub-tropics. Eddy covariance (EC) based ET measurements were made for two years at two previously drained and geographically close wetlands in the Everglades region of Florida. One wetland was significantly drained with 97% of its storage capacity lost. The other was a more functional wetland with 42% of storage capacity lost. Annual average ET at the significantly drained wetland was 836 mm, 34% less than the function wetland (1271 mm) and the difference was statistically significant (p = 0.001). Such differences in wetland ET in the same climatic region have not been observed. The difference in ET was mainly due to drainage driven differences in inundation and associated effects on net radiation (Rn) and local relative humidity. Two daily ET models, a regression (r2 = 0.80) and a Relevance Vector Machine (RVM) model (r2 = 0.84), were developed with the latter being more robust. These models, when used in conjunction with hydrologic models, improved ET predictions for drained wetlands. Predictions from an integrated model showed that more intensely drained wetlands at higher elevation should be targeted for restoration of downstream flows (flooding) because they have the ability to loose higher water volume through ET which increases available water storage capacity of wetlands. Daily ET models can predict changes in ET for improved evaluation of basin-scale effects of restoration programs and climate change scenarios.

  19. Development of Charge Drain Coatings: Final CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Elam, Jeffrey W. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-17

    The primary goal of this CRADA project was to develop and optimize tunable resistive coatings prepared by atomic layer deposition (ALD) for use as charge-drain coatings on the KLA-Tencor digital pattern generators (DPGs).

  20. Cryogenic Fuel Tank Draining Analysis Model

    Science.gov (United States)

    Greer, Donald

    1999-01-01

    One of the technological challenges in designing advanced hypersonic aircraft and the next generation of spacecraft is developing reusable flight-weight cryogenic fuel tanks. As an aid in the design and analysis of these cryogenic tanks, a computational fluid dynamics (CFD) model has been developed specifically for the analysis of flow in a cryogenic fuel tank. This model employs the full set of Navier-Stokes equations, except that viscous dissipation is neglected in the energy equation. An explicit finite difference technique in two-dimensional generalized coordinates, approximated to second-order accuracy in both space and time is used. The stiffness resulting from the low Mach number is resolved by using artificial compressibility. The model simulates the transient, two-dimensional draining of a fuel tank cross section. To calculate the slosh wave dynamics the interface between the ullage gas and liquid fuel is modeled as a free surface. Then, experimental data for free convection inside a horizontal cylinder are compared with model results. Finally, cryogenic tank draining calculations are performed with three different wall heat fluxes to demonstrate the effect of wall heat flux on the internal tank flow field.

  1. Roundtable. Strategies to discourage brain drain.

    Science.gov (United States)

    Kupfer, Linda; Hofman, Karen; Jarawan, Raya; McDermott, Jeanne; Bridbord, Ken

    2004-08-01

    Building health research expertise in developing countries often requires personnel to receive training beyond national borders. For research funding agencies that sponsor this type of training, a major goal is to ensure that trainees return to their country of origin: attaining this objective requires the use of proactive strategies. The strategies described were developed under the extramural acquired immunodeficiency syndrome (AIDS) International Training and Research Program (AITRP) funded by the Fogarty International Center (FIC) at the National Institutes of Health, United States. This programme supports universities in the United States that provide research training to scientists from developing countries to enable them to address the global epidemic of human immunodeficiency virus (HIV)/AIDS and the related tuberculosis (TB) epidemic. This paper describes the strategies employed to discourage brain drain by the principle investigators (PIs) of five of the longest-funded AITRPs (funded for 15 years). Long-term trainees in these programmes spent from 11 to 96 months (an average of 26 months) studying. Using scientific, political and economic strategies that address brain drain issues, PIs working in AITRPs have attained an average rate of return home for their trainees of 80%.

  2. Postoperative intraabdominal fluid collections : a modified percutaneous drainage method using a surgical drain track

    International Nuclear Information System (INIS)

    Lee, Deok Hee; Kim, Gab Choul; Hwang, Jae Cheol; Yoon, Hyun Ki; Song, Ho Young; Sung, Kyu Bo

    2000-01-01

    In the management of postoperative fluid collection, the conventional percutaneous drainage method can be employed. Because of abdominal incisions and various types of surgical drains and/or T-tubes, the application of this method is not always easy, however. We inserted a drainage catheter through a pre-existing percutaneous track formed by a surgical drain located adjacent to the site of abnormal fluid collection. There was no need to remove the drain nor make an additional puncture in the abdominal wall. A dilator was inserted along the drain, and a guide wire was used to negotiate its intraperitoneal track and reach the accumulated fluid. The procedure was simple and safe. We briefly describe our experience of this modified percutaneous drainage technique, as used in three cases involving postoperative fluid collection. (author)

  3. High performance AlGaN/GaN HEMTs with 2.4 μm source-drain spacing

    International Nuclear Information System (INIS)

    Wang Dongfang; Wei Ke; Yuan Tingting; Liu Xinyu

    2010-01-01

    This paper describes the performance of AlGaN/GaN HEMTs with 2.4 μm source-drain spacing. So far these are the smallest source-drain spacing AlGaN/GaN HEMTs which have been implemented with a domestic wafer and domestic process. This paper also compares their performance with that of 4 μm source-drain spacing devices. The former exhibit higher drain current, higher gain, and higher efficiency. It is especially significant that the maximum frequency of oscillation noticeably increased. (semiconductor integrated circuits)

  4. The routine use of post-operative drains in thyroid surgery: an outdated concept.

    LENUS (Irish Health Repository)

    Prichard, R S

    2010-01-01

    The use of surgical drains in patients undergoing thyroid surgery is standard surgical teaching. Life-threatening complications, arising from post-operative haematomas, mandates their utilization. There is increasing evidence to suggest that this is an outdated practice. This paper determines whether thyroid surgery can be safely performed without the routine use of drains. A retrospective review of patients undergoing thyroid surgery, over a three year period was performed and post-operative complications documented. One hundred and four thyroidectomies were performed. 63 (60.6%) patients had a partial thyroidectomy, 27 (25.9%) had a total thyroidectomy and 14 (13.5%) had a sub-total thyroidectomy. Suction drains were not inserted in any patient. A cervical haematoma did not develop in any patient in this series and no patient required re-operation. There is no evidence to suggest the routine use of surgical drains following uncomplicated thyroid surgery reduces the rate of haematoma formation or re-operation rates and indeed is now unwarranted.

  5. Preliminary design studies of the draining tanks for the Molten Salt Fast Reactor

    International Nuclear Information System (INIS)

    Merle-Lucotte, E.; Allibert, M.; Heuer, D.; Brovchenko, M.; Laureau, A.; Ghetta, V.; Rubiolo, P.

    2014-01-01

    reactor called the Molten Salt Fast Reactor (MSFR). The reference MSFR design is a 3000 MWth reactor with a total fuel salt volume of 18 m3, operated at a mean fuel temperature of 750 deg. C. The first confinement barrier of the reactor includes a salt draining system. In case of a planned reactor shut down or in case of accidents leading to an excessive increase of the temperature in the fuel circuit, the fuel configuration may be changed passively by gravitational draining of the fuel salt in dedicated draining tank located under the reactor and designed to provide adequate reactivity margins while insuring a passive cooling of the fuel salt to extract the residual heat from the short to the long term. The present preliminary assessment of this sub-critical draining system has been performed to identify the physical constraints and to give some orders of magnitude of characteristic time periods (authors)

  6. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    OpenAIRE

    Lin Long-Wei; Lo Chiao; Lai Peng-Sheng; Lee Po-Chu

    2010-01-01

    Abstract Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagoj...

  7. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    OpenAIRE

    Ayhan GENCLER

    2009-01-01

    Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems tha...

  8. Evaluation of the necessity for chest drain placement following thoracoscopic wedge resection.

    Science.gov (United States)

    Lu, Ting-Yu; Chen, Jian-Xun; Chen, Pin-Ru; Lin, Yu-Sen; Chen, Chien-Kuang; Kao, Pei-Yu; Huang, Tzu-Ming; Fang, Hsin-Yuan

    2017-05-01

    To evaluate the outcomes of patients who underwent thoracoscopic wedge resection without chest drain placement. The subjects of this retrospective study were 89 patients, who underwent thoracoscopic wedge resection at our hospital between January, 2013 and July, 2015. A total of 45 patients whose underlying condition did not meet the following criteria were assigned to the "chest drain placement group" (group A): peripheral lesions, healthy lung parenchyma, no intraoperative air leaks, hemorrhage or effusion accumulation, and no pleural adhesion. The other 44 patients whose underlying condition met the criteria were assigned to the "no chest drain placement group" (group B). Patient characteristics, specimen data, and postoperative conditions were analyzed and compared between the groups. Group A patients had poorer forced expiratory volume in one second (FEV1) values, less normal spirometric results, significantly higher resected lung volume, a greater maximum tumor-pleura distance, and a larger maximum tumor size. They also had a longer postoperative hospital stay. There was no difference between the two groups in postoperative complications. Avoiding chest drain placement after a thoracoscopic wedge resection appears to be safe and beneficial for patients who have small peripheral lesions and healthy lung parenchyma.

  9. Outcome in Chronic Subdural Hematoma After Subdural vs. Subgaleal Drain

    International Nuclear Information System (INIS)

    Ishfaq, A.

    2017-01-01

    Objective: To compare the outcome after surgery for chronic subdural hematoma when the drain is placed in subdural space or subgaleal space. Study Design: Quasi experimental study. Place and Duration of Study: Combined Military Hospital, Lahore, from July 2015 to June 2016. Methodology: Patients with chronic subdural hematoma of both genders and age, ranging between 55 to 85 years, were included. Patients on antiplatelet/anticoagulant therapy and acute on chronic subdural hematoma were excluded. Patients were divided in two equal groups each depending on whether drain was placed in subgaleal space (Group 1), and subdual space (Group 2), (n=31 patients each). Patients were positioned flat in bed after surgery. Clinical and radiological parameters and clinical outcome were compared between the two groups. Statistical test with significance of p <0.05 was utilized using Statistical Package of Social Sciences (SPSS version 17). Results: Median age of the 62 patients was 72 +-12.5 years. Headache was the most common symptom reported in both groups, (n=47,75.8%) patients. Median thickness of hematoma was 15 +-6.5 mm. Patients with subdural drain placement had more complications such as pneumocephalus 11 (35.4%) vs. 6 (19.3%), and intracerebral hemorrhage 4 (12.9%) vs. 2 (6.4%). Clinical outcome was good in both groups 27 (87%) in Group 1 and 28 (90%) in Group 2. Conclusion: Patients of both groups had good outcome after surgery. Complications like pneumocephalus and intracerebral hemorrhage were more common in subdural location of drain, though not reaching statistically significance level to favor one technique over another. (author)

  10. Breakthrough of two pesticides into tile drain and shallow groundwater: comparison of tile drain reaction and soil profiles within a field scale irrigation experiment

    Science.gov (United States)

    Klaus, Julian; Zehe, Erwin; Elsner, Martin; Palm, Juliane; Schneider, Dorothee; Schröder, Boris; Steinbeiss, Sibylle; West, Stephanie

    2010-05-01

    Preferential flow in macropores is a key process which strongly affects infiltration and may cause rapid transport of pesticides into depths of 80 to 150 cm. At these depths they experience a much slower degradation, may leach into shallow groundwater or enter a tile-drain and are transported into surface water bodies. Therefore, preferential transport might be an environmental problem, if the topsoil is bypassed, which has been originally thought to act as a filter to protect the subsoil and shallow groundwater. To investigate the behaviour of two pesticides with different chemical characteristics and to compare their transport behaviour in soil and into the tile drain an irrigation experiment was performed on a 400 m² field site. The experimental plot is located in the Weiherbach valley, south-west Germany, which basic geology consists of Loess and Keuper layers, the soil at the test site is a gleyic Colluvisol. The distance of the irrigation site to the Weiherbach brook is approximately 12 m, the field is drained with a tile-drain in about 1.2 m depth and shows discharge over the entire year. Three hours before the irrigation started, the farmer applied a pesticide solution consisting of Isoproturon (80 g) and Flufenacet (20 g) (IPU and FLU) according to conventional agricultural practice on the field plot. The irrigation took place in three time blocks (80 min, 60 min, 80 min) with in total 33.6 mm of precipitation. During the first block 1600 g of Bromide were mixed in the irrigation water. The drainage outlet was instrumented with a pressure probe. About 50 water samples ware taken during the experimental day, and several samples more the days after the experiment. They were analysed for the pesticides, bromide and water isotopes. In the two days after the experiment three soil profiles were excavated and soil samples were taken on a 10x10 cm² scheme. One week after the experiment two additional profiles were excavated. The soil was analysed for IPU, FLU

  11. Replacement of the drain system of secondary circuit at Monju

    International Nuclear Information System (INIS)

    Itoh, Kenji; Onuki, Koji; Tomobe, Katsuma; Taniyama, Sadami

    2003-01-01

    Monju is as a Japan's prototype fast breeder reactor cooled by liquid sodium. In the course of power buildup tests, the sodium leakage accident broke out on 8th December 1995. Though Monju has been already equipped with countermeasure systems against the sodium leakage accident, some additional improvements will be taken in order to reduce the damage by the leaked sodium when another leakage accident should recur. The most characteristic work is the drain system modification that leads to shorten the drain time and to reduce the quantity of leaked sodium in the event of sodium leakage. (author)

  12. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    OpenAIRE

    Gencler, Ayhan

    2009-01-01

    Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems that, in general, developing or underdeveloped...

  13. Establishment and application of the estimation model for pollutant concentrfation in agriculture drain

    Science.gov (United States)

    Li, Qiangkun; Hu, Yawei; Jia, Qian; Song, Changji

    2018-02-01

    It is the key point of quantitative research on agricultural non-point source pollution load, the estimation of pollutant concentration in agricultural drain. In the guidance of uncertainty theory, the synthesis of fertilization and irrigation is used as an impulse input to the farmland, meanwhile, the pollutant concentration in agricultural drain is looked as the response process corresponding to the impulse input. The migration and transformation of pollutant in soil is expressed by Inverse Gaussian Probability Density Function. The law of pollutants migration and transformation in soil at crop different growth periods is reflected by adjusting parameters of Inverse Gaussian Distribution. Based on above, the estimation model for pollutant concentration in agricultural drain at field scale was constructed. Taking the of Qing Tong Xia Irrigation District in Ningxia as an example, the concentration of nitrate nitrogen and total phosphorus in agricultural drain was simulated by this model. The results show that the simulated results accorded with measured data approximately and Nash-Sutcliffe coefficients were 0.972 and 0.964, respectively.

  14. Viscosity-dependent drain current noise of AlGaN/GaN high electron mobility transistor in polar liquids

    International Nuclear Information System (INIS)

    Fang, J. Y.; Hsu, C. P.; Kang, Y. W.; Fang, K. C.; Kao, W. L.; Yao, D. J.; Chen, C. C.; Li, S. S.; Yeh, J. A.; Wang, Y. L.; Lee, G. Y.; Chyi, J. I.; Hsu, C. H.; Huang, Y. F.; Ren, F.

    2013-01-01

    The drain current fluctuation of ungated AlGaN/GaN high electron mobility transistors (HEMTs) measured in different fluids at a drain-source voltage of 0.5 V was investigated. The HEMTs with metal on the gate region showed good current stability in deionized water, while a large fluctuation in drain current was observed for HEMTs without gate metal. The fluctuation in drain current for the HEMTs without gate metal was observed and calculated as standard deviation from a real-time measurement in air, deionized water, ethanol, dimethyl sulfoxide, ethylene glycol, 1,2-butanediol, and glycerol. At room temperature, the fluctuation in drain current for the HEMTs without gate metal was found to be relevant to the dipole moment and the viscosity of the liquids. A liquid with a larger viscosity showed a smaller fluctuation in drain current. The viscosity-dependent fluctuation of the drain current was ascribed to the Brownian motions of the liquid molecules, which induced a variation in the surface dipole of the gate region. This study uncovers the causes of the fluctuation in drain current of HEMTs in fluids. The results show that the AlGaN/GaN HEMTs may be used as sensors to measure the viscosity of liquids within a certain range of viscosity

  15. A Drain Current Model Based on the Temperature Effect of a-Si:H Thin-Film Transistors

    International Nuclear Information System (INIS)

    Qiang Lei; Yao Ruo-He

    2012-01-01

    Based on the differential Ohm's law and Poisson's equation, an analytical model of the drain current for a-Si:H thin-film transistors is developed. This model is proposed to elaborate the temperature effect on the drain current, which indicates that the drain current is linear with temperature in the range of 290-360 K, and the results fit well with the experimental data

  16. Gauze Impregnated With Quaternary Ammonium Salt Reduces Bacterial Colonization of Surgical Drains After Breast Reconstruction.

    Science.gov (United States)

    Strong, Amy L; Wolfe, Emily T; Shank, Nina; Chaffin, Abigail E; Jansen, David A

    2018-06-01

    Surgical site infection after breast reconstruction is associated with increased length of hospital stay, readmission rates, cost, morbidity, and mortality. Identifying methods to reduce surgical site infection without the use of antibiotics may be beneficial at reducing antimicrobial resistance, reserving the use of antibiotics for more severe cases. Quaternary ammonium salts have previously been shown to be a safe and effective antimicrobial agent in the setting of in vitro and in vivo animal experiments. A retrospective study was conducted to investigate the antimicrobial properties of a quaternary ammonium salt, 3-trimethoxysilyl propyldimethyloctadecyl ammonium chloride (QAS-3PAC; Bio-spear), at reducing surgical drain site colonization and infection after breast reconstruction (deep inferior epigastric perforator flap reconstruction or tissue expander placement). Twenty patients were enrolled, with 14 surgical drains covered with nonimpregnated gauze and 17 surgical drains covered with QAS-3PAC impregnated gauze, for the purposes of investigating bacterial colonization. Antibiotic sensitivity analysis was also conducted when bacterial cultures were positive. The overall incidence of bacterial colonization of surgical drains was lower in the treatment group compared with the control group (17.6% vs 64.3%, respectively; P = 0.008). QAS-3PAC impregnated gauze reduced the incidence of bacterial colonization of surgical drains during the first (0.0% vs 33.3%) and second (33.3% vs 87.5%; P = 0.04) postoperative week. Furthermore, no enhanced antibiotic resistance was noted on drains treated with QAS-3PAC impregnated gauze. The results of this study suggest that QAS-3PAC impregnated gauze applied over surgical drains may be an effective method for reducing the incidence of bacterial colonization.

  17. Surface runoff and subsurface tile drain losses of neonicotinoids and companion herbicides at edge-of-field.

    Science.gov (United States)

    Chrétien, François; Giroux, Isabelle; Thériault, Georges; Gagnon, Patrick; Corriveau, Julie

    2017-05-01

    With their application as seed coatings, the use of neonicotinoid insecticides increased dramatically during the last decade. They are now frequently detected in aquatic ecosystems at concentrations susceptible to harm aquatic invertebrates at individual and population levels. This study intent was to document surface runoff and subsurface tile drain losses of two common neonicotinoids (thiamethoxam and clothianidin) compared to those of companion herbicides (atrazine, glyphosate, S-metolachlor and mesotrione) at the edge of a 22.5-ha field under a corn-soybean rotation. A total of 14 surface runoff and tile drain discharge events were sampled over two years. Events and annual unit mass losses were computed using flow-weighted concentrations and total surface runoff and tile drain flow volumes. Detection frequencies close to 100% in edge-of-field surface runoff and tile drain water samples were observed for thiamethoxam and clothianidin even though only thiamethoxam had been applied in the first year. In 2014, thiamethoxam median concentrations in surface runoff and tile drain samples were respectively 0.46 and 0.16 μg/L, while respective maximum concentrations of 2.20 and 0.44 μg/L were measured in surface runoff and tile drain samples during the first post-seeding storm event. For clothianidin, median concentrations in surface runoff and tile drain samples were 0.02 and 0.01, μg/L, and respective maximum concentrations were 0.07 μg/L and 0.05 μg/L. Surface runoff and tile drain discharge were key transport mechanisms with similar contributions of 53 and 47% of measured mass losses, respectively. Even if thiamethoxam was applied at a relatively low rate and had a low mass exportation value (0.3%), the relative toxicity was one to two orders of magnitude higher than those of the other chemicals applied in 2014 and 2015. Companion herbicides, except glyphosate in tile drains, exceeded their water quality guideline during one sampling campaign after

  18. Method of making a self-aligned schottky metal semi-conductor field effect transistor with buried source and drain

    International Nuclear Information System (INIS)

    Bol, I.

    1984-01-01

    A semi-conductor structure and particularly a high speed VLSI Self-Aligned Schottky Metal Semi-Conductor Field Effect Transistor with buried source and drain, fabricated by the ion implantation of source and drain areas at a predetermined range of depths followed by very localized laser annealing to electrically reactivate the amorphous buried source and drain areas thereby providing effective vertical separation of the channel from the buried source and drain respectively. Accordingly, spatial separations between the self-aligned gate-to-drain, and gate-to-source can be relatively very closely controlled by varying the doping intensity and duration of the implantation thereby reducing the series resistance and increasing the operating speed

  19. Rare bile duct anomaly: B3 duct draining to gallbladder

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2016-01-01

    Full Text Available A 10-year-old girl presented with recurrent right upper abdominal pain and dyspepsia. Magnetic resonance cholangiopancreatography revealed a dilated common channel of intrahepatic bile duct of segment 3 (B3 and segment 4 (B4 drained into the gallbladder directly. The patient underwent laparoscopic cholecystectomy and Roux-en Y hepaticojejunostomy (B3-jejunostomy. Among the anatomical variability of the biliary system, the cholecystohepatic ducts are controversial in existence and incidence. We report a very rare variant of a cholecystohepatic duct in which the B3 duct drained into gallbladder directly and to the best of our knowledge this is the first report.

  20. The fabrication of carbon nanotube field-effect transistors with semiconductors as the source and drain contact materials.

    Science.gov (United States)

    Xiao, Z; Camino, F E

    2009-04-01

    Sb(2)Te(3) and Bi(2)Te(2)Se semiconductor materials were used as the source and drain contact materials in the fabrication of carbon nanotube field-effect transistors (CNTFETs). Ultra-purified single-walled carbon nanotubes (SWCNTs) were ultrasonically dispersed in N-methyl pyrrolidone solvent. Dielectrophoresis was used to deposit and align SWCNTs for fabrication of CNTFETs. The Sb(2)Te(3)- and Bi(2)Te(2)Se-based CNTFETs demonstrate p-type metal-oxide-silicon-like I-V curves with high on/off drain-source current ratio at large drain-source voltages and good saturation of drain-source current with increasing drain-source voltage. The fabrication process developed is novel and has general meaning, and could be used for the fabrication of SWCNT-based integrated devices and systems with semiconductor contact materials.

  1. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    The Xpand chest drain is an external medical device made of plastic that incorporates a fluid reservoir, a one-way valve and an air-leak detection system ... conect ed to a 2 000 ml drainage bag) prevents exposure of body fluids to nursing staff.

  2. Drains after Thyroidectomy for Benign Thyroid Disorders; Are ...

    African Journals Online (AJOL)

    Prophylactic drainage after thyroidectomy has been a regular practice at Kenyatta National Hospital( KNH). This has been ... stay and post-operative pain. Introduction. Prophylactic drains are still regularly used in ..... Total versus subtotal thyroidectomy for the management of benign multinodular goiter in an endemic region.

  3. Accounting for the risks of phosphorus losses through tile drains in a phosphorus index.

    Science.gov (United States)

    Reid, D Keith; Ball, Bonnie; Zhang, T Q

    2012-01-01

    Tile drainage systems have been identified as a significant conduit for phosphorus (P) losses to surface water, but P indices do not currently account for this transport pathway in a meaningful way. Several P indices mention tile drains, but most account for either the reduction in surface runoff or the enhanced transport through tiles rather than both simultaneously. A summary of the current state of how tile drains are accounted for within P indices is provided, and the challenges in predicting the risk of P losses through tile drains that are relative to actual losses are discussed. A framework for a component P Index is described, along with a proposal to incorporate predictions of losses through tile drains as a component within this framework. Options for calibrating and testing this component are discussed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  4. Impact of a drain field plate on the breakdown characteristics of AlInN/GaN MOSHEMT

    Science.gov (United States)

    Jena, Kanjalochan; Swain, Raghunandan; Lenka, T. R.

    2015-11-01

    In this paper, a novel AlInN/GaN metal oxide semiconductor high electron mobility transistor (MOSHEMT) employing the drain field plate technique is proposed and the effect of a drain field plate on the breakdown voltage (BV) is investigated. A reduction of the peak electric field is required to achieve AlInN/GaN MOSHEMTs with a high BV. The proposed AlInN/GaN MOSHEMT with both gate and drain field plates simultaneously reduces the electric field concentration at the gate and the drain edge by decreasing the potential gradient along the channel for the 2 dimensional electron gas (2DEG). The reduction in the peak electric field at the drain edge of the proposed device leads to a 57% increase in BV compared with the BV for an AlInN/GaN MOSHEMT with a gate field plate only. A significantly higher BV can be achieved by optimizing the gate-to-drain distance (L gd ), the length of the drain field plate (L dfp ) and the thickness of the SiN passivation layer thickness (T SiN ). A detailed breakdown analysis of the device was carried out using Silvaco Technology Computer Aided Design (TCAD). The detailed numerical simulations were done by using the non-local energy balance (EB) transport model, which was calibrated with the previously published experimental results. The results showed a great potential for applications of the drain-field-plated AlInN/GaN MOSHEMT to deliver high currents and high powers in microwave technologies.

  5. Outcomes of Transhiatal and Intercostal Pleural Drain After Ivor Lewis Esophagectomy: Comparative Analysis of Two Consecutive Patient Cohorts.

    Science.gov (United States)

    Asti, Emanuele; Bernardi, Daniele; Bonitta, Gianluca; Bonavina, Luigi

    2018-05-01

    In a previous proof of concept study, transhiatal pleural drain has been shown to be safe and effective after hybrid Ivor Lewis esophagectomy. Aim of this study was to compare the short-term outcomes of transhiatal and intercostal pleural drainage. This is an observational retrospective cohort study. Two methods of pleural drainage were compared in patients undergoing hybrid Ivor Lewis esophagectomy. Patients treated with a transhiatal drain connected to a vacuum bag were compared to a historical cohort of patients treated with the conventional intercostal drain connected to underwater seal and suction. Postoperative morbidity, total and daily drainage output, serum albumin levels, and total dose of paracetamol and ketorolac administered on demand were recorded. Between January 2014 and December 2016, 50 patients with transhiatal drain and 50 with intercostal drains met the criteria for inclusion in the study. Demographic and clinicopathological variables were similar in the two groups. There was no statistically significant difference in the rate of postoperative complications. The total volume of drain output and the serum albumin levels were similar in the two groups. The total dose of ketorolac was significantly reduced in patients with transhiatal drain (P pleural drainage connected to a portable vacuum system could safely replace the intercostal drain after hybrid Ivor Lewis esophagectomy. It has the potential to reduce postoperative pain and use of nonsteroidal anti-inflammatory drugs, and to enhance recovery from surgery.

  6. Characterization of Drain Surface Water: Environmental Profile, Degradation Level and Geo-statistic Monitoring

    International Nuclear Information System (INIS)

    Mumtaz, M.W.; Raza, M.A.; Ahmed, Z.; Abbas, M.N.; Hussain, M.

    2015-01-01

    The physico-chemical characterization of the surface water. Samples was carried out collected from nine sampling points of drain passing by the territory of Hafizabad city, Punjab, Pakistan. The water of drain is used by farmers for irrigation purposes in nearby agricultural fields. Twenty water quality parameters were evaluated in three turns and the results obtained were compared with the National Environmental Quality Standards (NEQS) municipal and industrial effluents prescribed limits. The highly significant difference (p<0.01) was recorded for the content of phenols, carbonyl compounds, cyanides, dissolved oxygen, biological oxygen demand, total soluble salts, total dissolved salts, nitrates and sulphates, whereas, the concentration of magnesium, potassium and oil and grease differed significantly (p<0.05) with respect to the sampling points on average basis. Non-significant difference (p>0.05) was noted for temperature, pH, electrical conductivity, hardness, calcium, sodium, chemical oxygen demand and chloride among water samples from different sampling points. Furthermore, the experimental results of different water quality parameters studied at nine sampling points of the drain were used and interpolated in ArcGIS 9.3 environment system using kriging techniques to obtain calculated values for the remaining locations of the Drain. (author)

  7. Enhanced performance of amorphous In-Ga-Zn-O thin-film transistors using different metals for source/drain electrodes

    Science.gov (United States)

    Pyo, Ju-Young; Cho, Won-Ju

    2017-09-01

    In this paper, we propose an amorphous indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) with off-planed source/drain electrodes. We applied different metals for the source/drain electrodes with Ni and Ti to control the work function as high and low. When we measured the configuration of Ni to drain and source to Ti, the a-IGZO TFT showed increased driving current, decreased leakage current, a high on/off current ratio, low subthreshold swing, and high mobility. In addition, we conducted a reliability test with a gate bias stress test at various temperatures. The results of the reliability test showed the Ni drain and Ti drain had an equivalent effective energy barrier height. Thus, we confirmed that the proposed off-planed structure improved the electrical characteristics of the fabricated devices without any degradation of characteristics. Through the a-IGZO TFT with different source/drain electrode metal engineering, we realized high-performance TFTs for next-generation display devices.

  8. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  9. Photoactive TiO2 Films Formation by Drain Coating for Endosulfan Degradation

    Directory of Open Access Journals (Sweden)

    Natalia Tapia-Orozco

    2013-01-01

    Full Text Available Heterogeneous photocatalysis is an advanced oxidation process in which a photoactive catalyst, such as TiO2, is attached to a support to produce free radical species known as reactive oxygen species (ROS that can be used to break down toxic organic compounds. In this study, the draining time, annealing temperature, and draining/annealing cycles for TiO2 films grown by the drain coating method were evaluated using a 23 factorial experimental design to determine the photoactivity of the films via endosulfan degradation. The TiO2 films prepared with a large number of draining/annealing cycles at high temperatures enhanced (P>0.05 endosulfan degradation and superoxide radical generation after 30 minutes of illumination with UV light. We demonstrated a negative correlation (R2=0.69; P>0.01 between endosulfan degradation and superoxide radical generation. The endosulfan degradation rates were the highest at 30 minutes with the F6 film. In addition, films prepared using conditions F1, F4, and F8 underwent an adsorption/desorption process. The kinetic reaction constants, Kapp (min−1, were 0.0101, 0.0080, 0.0055, 0.0048, and 0.0035 for F6, F2, F5, F3, and F1, respectively. The endosulfan metabolites alcohol, ether, and lactone were detected and quantified at varying levels in all photocatalytic assays.

  10. Carbon balance of rewetted and drained peat soils used for biomass production: A mesocosm study

    DEFF Research Database (Denmark)

    Karki, Sandhya; Elsgaard, Lars; Kandel, Tanka

    2016-01-01

    of lower CO2 emissions without losing agricultural land. The present study quantified the carbon balance (CO2, CH4 and harvested biomass C) of rewetted and drained peat soils under intensively managed reed canary grass (RCG) cultivation. Mesocosms were maintained at five different ground water levels (GWL......), i.e., 0, 10, 20 cm below the soil surface, representing rewetted peat soils, and 30 and 40 cm below the soil surface, representing drained peat soils. Net ecosystem exchange (NEE) of CO2 and CH4 emissions were measured during the growing period of RCG (May to September) using transparent and opaque...... closed chamber methods. The average dry biomass yield was significantly lower from rewetted peat soils (12 Mg ha−1) than drained peat soils (15 Mg ha−1). Also, CO2 fluxes of gross primary production (GPP) and ecosystem respiration (ER) from rewetted peat soils were significantly lower than drained peat...

  11. English and the Brain Drain : An Uncertain Relationship

    NARCIS (Netherlands)

    Houtkamp, C.

    2016-01-01

    In his book Linguistic Justice for Europe and the World, Van Parijs analyses in one of his chapters the brain drain from non-Anglophone to Anglophone countries, which hurts the economic development of the nonAnglophone states. Van Parijs deems it clear that English is a very important factor to

  12. Multiyear nutrient removal performance of three constructed wetlands intercepting tile drain flows from grazed pastures.

    Science.gov (United States)

    Tanner, Chris C; Sukias, James P S

    2011-01-01

    Subsurface tile drain flows can be a major s ource of nurient loss from agricultural landscapes. This study quantifies flows and nitrogen and phosphorus yields from tile drains at three intensively grazed dairy pasture sites over 3- to 5-yr periods and evaluates the capacity of constructed wetlands occupying 0.66 to 1.6% of the drained catchments too reduce nutrient loads. Continuous flow records are combined with automated flow-proportional sampling of nutrient concentrations to calculate tile drain nutrient yields and wetland mass removal rates. Annual drainage water yields rangedfrom 193 to 564 mm (16-51% of rainfall) at two rain-fed sites and from 827 to 853 mm (43-51% of rainfall + irrigation) at an irrigated site. Annually, the tile drains exported 14 to 109 kg ha(-1) of total N (TN), of which 58 to 90% was nitrate-N. Constructed wetlands intercepting these flows removed 30 to 369 gTN m(-2) (7-63%) of influent loadings annually. Seasonal percentage nitrate-N and TN removal were negatively associated with wetland N mass loadings. Wetland P removal was poor in all wetlands, with 12 to 115% more total P exported annually overall than received. Annually, the tile drains exported 0.12 to 1.38 kg ha of total P, of which 15 to 93% was dissolved reactive P. Additional measures are required to reduce these losses or provide supplementary P removal. Wetland N removal performance could be improved by modifying drainage systems to release flows more gradually and improving irrigation practices to reduce drainage losses.

  13. The hydrology of a drained topographical depression within an agricutlural field in north-central Iowa

    Science.gov (United States)

    Roth, Jason L.; Capel, Paul D.

    2012-01-01

    North-central Iowa is an agriculturally intensive area comprising the southeastern portion of the Prairie Pothole Region, a landscape containing a high density of enclosed topographical depressions. Artificial drainage practices have been implemented throughout the area to facilitate agricultural production. Vertical surface drains are utilized to drain the topographical depressions that accumulate water. This study focuses on the hydrology of a drained topographical depression located in a 39.5 ha agricultural field. To assess the hydrology of the drained depression, a water balance was constructed for 11 ponding events during the 2008 growing season. Continuous pond and groundwater level data were obtained with pressure transducers. Flows into the vertical surface drain were calculated based on pond depth. Precipitation inflows and evaporative outflows of the ponds were calculated using climatic data. Groundwater levels were used to assess groundwater/pond interactions. Results of the water balances show distinct differences between the inflows to and outflows from the depression based on antecedent conditions. In wet conditions, groundwater inflow sustained the ponds. The ponds receded only after the groundwater level declined to below the land surface. In drier conditions, groundwater was not a source of water to the depression. During these drier conditions, infiltration comprised 30% of the outflows from the depression during declining pond stages. Over the entire study period, the surface drain, delivering water to the stream, was the largest outflow from the pond, accounting for 97% of the outflow, while evapotranspiration was just 2%. Precipitation onto the pond surface proved to be a minor component, accounting for 4% of the total inflows.

  14. Technical meeting on decommissioning of fast reactors after sodium draining. Working material

    International Nuclear Information System (INIS)

    2005-01-01

    The objective of the technical meeting was to provide a forum for in-depth scientific and technical exchange on topics related to the decommissioning experience with fast reactors, in particular with regard to the decommissioning of components after sodium draining. Accordingly, the scope of the meeting covers the review and analyses of the experience gained from the decommissioning of both active sodium loops and sodium cooled fast reactors (e.g., KNK II, Superphenix, RAPSODIE, EBR-II, FERMI, BN-350, BR-10). It is expected that the outcome of the meeting will contribute to the Agency initiative to preserve fast reactor data and knowledge. The main focus of the technical meeting was given on the decommissioning of both active loop and reactor components (e.g., the primary vessel of a sodium-cooled reactor) that have been drained of sodium, but that still conserve some residual amounts of sodium (e.g., films covering the entire surface of the component, or particular sodium heels that cannot be drained)

  15. Differences in microbial community structure and nitrogen cycling in natural and drained tropical peatland soils.

    Science.gov (United States)

    Espenberg, Mikk; Truu, Marika; Mander, Ülo; Kasak, Kuno; Nõlvak, Hiie; Ligi, Teele; Oopkaup, Kristjan; Maddison, Martin; Truu, Jaak

    2018-03-16

    Tropical peatlands, which play a crucial role in the maintenance of different ecosystem services, are increasingly drained for agriculture, forestry, peat extraction and human settlement purposes. The present study investigated the differences between natural and drained sites of a tropical peatland in the community structure of soil bacteria and archaea and their potential to perform nitrogen transformation processes. The results indicate significant dissimilarities in the structure of soil bacterial and archaeal communities as well as nirK, nirS, nosZ, nifH and archaeal amoA gene-possessing microbial communities. The reduced denitrification and N 2 -fixing potential was detected in the drained tropical peatland soil. In undisturbed peatland soil, the N 2 O emission was primarily related to nirS-type denitrifiers and dissimilatory nitrate reduction to ammonium, while the conversion of N 2 O to N 2 was controlled by microbes possessing nosZ clade I genes. The denitrifying microbial community of the drained site differed significantly from the natural site community. The main reducers of N 2 O were microbes harbouring nosZ clade II genes in the drained site. Additionally, the importance of DNRA process as one of the controlling mechanisms of N 2 O fluxes in the natural peatlands of the tropics revealed from the results of the study.

  16. Importance of including small-scale tile drain discharge in the calibration of a coupled groundwater-surface water catchment model

    DEFF Research Database (Denmark)

    Hansen, Anne Lausten; Refsgaard, Jens Christian; Christensen, Britt Stenhøj Baun

    2013-01-01

    the catchment. In this study, a coupled groundwater-surface water model based on the MIKE SHE code was developed for the 4.7 km2 Lillebæk catchment in Denmark, where tile drain flow is a major contributor to the stream discharge. The catchment model was calibrated in several steps by incrementally including...... the observation data into the calibration to see the effect on model performance of including diverse data types, especially tile drain discharge. For the Lillebæk catchment, measurements of hydraulic head, daily stream discharge, and daily tile drain discharge from five small (1–4 ha) drainage areas exist....... The results showed that including tile drain data in the calibration of the catchment model improved its general performance for hydraulic heads and stream discharges. However, the model failed to correctly describe the local-scale dynamics of the tile drain discharges, and, furthermore, including the drain...

  17. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    leakage from 'open to air' system or breakage of glass bottle (with associated risk to ... and an air-leak detection system. It is connected to a ... need to add water. Xpand chest drain: assessing equivalence to current standard therapy – a randomised controlled trial. CHARL COOPER, M.B. CH.B. TIMOTHY HARDCASTLE ...

  18. Anomie and the "Brain Drain": A Sociological Explanation.

    Science.gov (United States)

    Karadima, Oscar

    The concept of anomie is proposed as one sociological variable that may explain the "brain drain" phenomenon (i.e., the movement of highly qualified personnel from their country of origin to another, most often a more developed, technologically advanced country). It is hypothesized that the higher the level of anomie found among…

  19. Organic loss in drained wetland: managing the carbon footprint

    NARCIS (Netherlands)

    Durham, B.; van de Noort, R.; Martens, V.V.; Vorenhout, M.

    2012-01-01

    The recent installation of land drains at Star Carr, Yorkshire, UK, has been linked with loss of preservation quality in this important Mesolithic buried landscape, challenging the PARIS principle. Historically captured organic carbon, including organic artefacts, is being converted to soluble

  20. A vapor generator equipped with an advanced drain device for the secondary side of the tubes plate

    International Nuclear Information System (INIS)

    Valadon, C.

    1995-01-01

    A draining design is proposed for the tube plate secondary side in a PWR type reactor, that does not interfere with the water flush 'street' thus allowing for an easy inspection and maintenance in the lower part of the tube bundle. The draining system is composed of a main groove on the upper side of the tube plate, which is connected to draining means situated outside the vapor generator. 6 fig

  1. Evapotranspiration from drained wetlands with different hydrologic regimes: Drivers, modeling, and storage functions

    Science.gov (United States)

    Wu, Chin-Lung; Shukla, Sanjay; Shrestha, Niroj K.

    2016-07-01

    We tested whether the current understanding of insignificant effect of drainage on evapotranspiration (ET) in the temperate region wetlands applies to those in the subtropics. Hydro-climatic drivers causing the changes in drained wetlands were identified and used to develop a generic model to predict wetland ET. Eddy covariance (EC)-based ET measurements were made for two years at two differently drained but close by wetlands, a heavily drained wetland (SW) (97% reduced surface storage) and a more functional wetland (DW) (42% reduced storage). Annual ET for more intensively drained SW was 836 mm, 34% less than DW (1271 mm) and the difference was significant (p = 0.001). This difference was mainly due to drainage driven differences in inundation and associated effects on net radiation (Rn) and local relative humidity. Two generic daily ET models, a regression model (MSE = 0.44 mm2, R2 = 0.80) and a machine learning-based Relevance Vector Machine (RVM) model (MSE = 0.36 mm2, R2 = 0.84), were developed with the latter being more robust. The RVM model can predict changes in ET for different restoration scenarios; a 1.1 m rise in drainage level showed 7% increase ET (18 mm) at SW while the increase at DW was negligible. The additional ET, 28% of surface flow, can enhance water storage, flood protection, and climate mitigation services at SW compared to DW. More intensely drained wetlands at higher elevation should be targeted for restoration for enhanced storage through increased ET. The models developed can predict changes in ET for improved evaluation of basin-scale effects of restoration programs and climate change scenarios.

  2. Use of laterally placed vacuum drains for management of aural hematomas in five dogs.

    Science.gov (United States)

    Pavletic, Michael M

    2015-01-01

    5 dogs (a Newfoundland, Golden Retriever, Shiba Inu, Staffordshire Terrier, and Vizsla) were referred for evaluation and treatment of unilateral aural hematomas within a week after their formation. Aural hematomas involved the left (3) or right (2) ears. With patients under anesthesia, the aural hematomas were approached surgically from the convex, or lateral, pinnal surface. Two small incisions were used to position a vacuum drain into the incised hematoma cavity. The drain exited at the base of the pinna and adjacent cervical skin. The free end of the drain was attached to a vacuum reservoir for 18 to 21 days. Drains and skin sutures were removed at this time along with the protective Elizabethan collar. All hematomas resolved and surgical sites healed during the minimum 6-month follow-up period. Cosmetic results were considered excellent in 4 of 5 patients. Slight wrinkling of the pinna in 1 patient resulted from asymmetric enlargement of the cartilaginous walls of the hematoma, where vacuum application resulted in a slight folding of the redundant lateral cartilage wall. The described treatment was efficient, economical, and minimally invasive and required no bandaging or wound care. Placement of the drain tubing on the convex (lateral) aspect sheltered the system from displacement by patients with an Elizabethan collar in place. Overall cosmetic results were excellent; asymmetric enlargement of the cartilaginous walls of the hematoma with slight folding of the pinna was seen in 1 patient.

  3. Comparative effect of tube drain on post operative inflammatory complications of impacted mandibular third molar surgery College Hospital, Ibadan, Nigeria.

    Science.gov (United States)

    Obimakinde, O S; Fasola, A O; Arotiba, J T; Okoje, V N; Obiechina, A E

    2010-09-01

    Swelling, pain and trismus are acute reversible inflammatory complications of impacted mandibular third molar (M3) surgery. They contribute to the deterioration of quality of life and loss of several useful working hours. This study aimed to investigate whether the use of a surgical drain following M3 surgery can minimise these inflammatory complications. Eighty consecutive patients who gave consent were enrolled into the study. Patients were assigned into two groups (drain and no drain) by systematic sampling method which was modified to ensure matching of patients by age, sex and spatial relationship of the impacted mandibular third molar. The patients in the drain group (n=40) had a Foley's catheter drain inserted into the wound after the surgical procedure while the patients in the no drain group (n=40) had their wound closed without the use of drain. All patients had primary wound closure with 3.0 black silk sutures after the procedure. Demographic data, cheek dimension and maximal mouth opening were recorded before the procedure. Pain, swelling and trismus were evaluated in the two groups at 24 hours, 48 hours and 7th day after surgery. Post operative swelling and visual analogue scale score for pain were comparatively lesser in the drain group patients. The maximal interincisal distance was also more in the drain group patients. The findings from this study indicated that there is a significant benefit of using a surgical drain in minimising postoperative oedema, pain and trismus following surgical removal of impacted mandibular third molar.

  4. Influence of pleural drain insertion in lung function of patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Ozelami Vieira, Irinea Beatriz Carvalho; Vieira, Fabiano F; Abrão, João; Gastaldi, Ada Clarice

    2012-01-01

    Longitudinal, prospective, randomized, blinded Trial to assess the influence of pleural drain (non-toxic PVC) site of insertion on lung function and postoperative pain of patients undergoing coronary artery bypass grafting in the first three days post-surgery and immediately after chest tube removal. Thirty six patients scheduled for elective myocardial revascularization with cardiopulmonary bypass (CPB) were randomly allocated into two groups: SX group (subxiphoid) and IC group (intercostal drain). Spirometry, arterial blood gases, and pain tests were recorded. Thirty one patients were selected, 16 in SX group and 15 in IC group. Postoperative (PO) spirometric values were higher in SX than in IC group (ppleural drain location on breathing. PaO(2) on the second PO increased significantly in SX group compared with IC group (pDrain with insertion in the subxiphoid region causes less change in lung function and discomfort, allowing better recovery of respiratory parameters. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  5. Navajo Nation Brain Drain: An Exploration of Returning College Graduates’ Perspectives

    Directory of Open Access Journals (Sweden)

    Quintina Ava Bearchief-Adolpho

    2017-01-01

    Full Text Available American Indian tribes face the phenomenon known across the world as the brain drain. They invest millions of dollars in educating their members only to have little return on their investment. Many nation members leave reservations to get postsecondary education but never return. Those who get education off the reservation and choose to return are the exception to this rule. Although there is an abundance of literature regarding brain drain across the world, there has been little research done with American Indians. In order to begin to understand the brain drain phenomenon, this study analyzed unstructured qualitative interviews with 17 Navajo Nation members who left their reservation, obtained a degree, and returned to work on the reservation. Themes resulting from the hermeneutic analysis of transcribed interviews were (a Family Support, (b Community, (c Cultural Identity, (d the Simple Life, (e Reservation Economy, and (f Commitment to the Reservation. The analysis found that constant, lengthy, and meaningful relationships were motivating factors in drawing participants back to contribute to their reservations. Further study is needed to understand how communities and tribes can ensure that these relationships are built and maintained.

  6. Restructuring brain drain: strengthening governance and financing for health worker migration

    Directory of Open Access Journals (Sweden)

    Tim K. Mackey

    2013-01-01

    Full Text Available Background: Health worker migration from resource-poor countries to developed countries, also known as ‘‘brain drain’’, represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Methods: Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Results: Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. Conclusions: In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed.

  7. Mechanism of improving forward and reverse blocking voltages in AlGaN/GaN HEMTs by using Schottky drain

    International Nuclear Information System (INIS)

    Zhao Sheng-Lei; Mi Min-Han; Luo Jun; Wang Yi; Dai Yang; Zhang Jin-Cheng; Ma Xiao-Hua; Hao Yue; Hou Bin

    2014-01-01

    In this paper, we demonstrate that a Schottky drain can improve the forward and reverse blocking voltages (BVs) simultaneously in AlGaN/GaN high-electron mobility transistors (HEMTs). The mechanism of improving the two BVs is investigated by analysing the leakage current components and by software simulation. The forward BV increases from 72 V to 149 V due to the good Schottky contact morphology. During the reverse bias, the buffer leakage in the Ohmicdrain HEMT increases significantly with the increase of the negative drain bias. For the Schottky-drain HEMT, the buffer leakage is suppressed effectively by the formation of the depletion region at the drain terminal. As a result, the reverse BV is enhanced from −5 V to −49 V by using a Schottky drain. Experiments and the simulation indicate that a Schottky drain is desirable for power electronic applications. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  8. Novel technique of source and drain engineering for dual-material double-gate (DMDG) SOI MOSFETS

    Science.gov (United States)

    Yadav, Himanshu; Malviya, Abhishek Kumar; Chauhan, R. K.

    2018-04-01

    The dual-metal dual-gate (DMDG) SOI has been used with Dual Sided Source and Drain Engineered 50nm SOI MOSFET with various high-k gate oxide. It has been scrutinized in this work to enhance its electrical performance. The proposed structure is designed by creating Dual Sided Source and Drain Modification and its characteristics are evaluated on ATLAS device simulator. The consequence of this dual sided assorted doping on source and drain side of the DMDG transistor has better leakage current immunity and heightened ION current with higher ION to IOFF Ratio. Which thereby vesting the proposed device appropriate for low power digital applications.

  9. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    Science.gov (United States)

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  10. Brain drain or brain gain : The case of Suriname

    NARCIS (Netherlands)

    T.W. Dulam (Tina)

    2015-01-01

    markdownabstractAbstract Brain drain refers to the emigration of highly skilled individuals mostly from a less developed (home) to a developed country (destination) thereby reducing the capacity of the home country to generate welfare for its population. In the literature there is much written

  11. Phosphorus modeling in tile drained agricultural systems using APEX

    Science.gov (United States)

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  12. Structural alterations in tumor-draining lymph nodes before papillary thyroid carcinoma metastasis.

    Science.gov (United States)

    Hinson, Andrew M; Massoll, Nicole A; Jolly, Lee Ann; Stack, Brendan C; Bodenner, Donald L; Franco, Aime T

    2017-08-01

    The purpose of this study was to define and characterize the thyroid tumor-draining lymph nodes in genetically engineered mice harboring thyroid-specific expression of oncogenic Braf V600E with and without Pten insufficiency. After intratumoral injection of methylene blue, the lymphatic drainage of the thyroid gland was visualized in real time. The thyroid gland/tumor was resected en bloc with the respiratory system for histological analysis. Although mice harboring Braf V600E mutations were smaller in body size compared with their wild-type (WT) littermates, the size of their thyroid glands and deep cervical lymph nodes were significantly larger. Additionally, the tumor-draining lymph nodes showed increased and enlarged lymphatic sinuses that were distributed throughout the cortex and medulla. Tumor-reactive lymphadenopathy and histiocytosis, but no frank metastases, were observed in all mice harboring Braf V600E mutations. The tumor-draining lymph nodes undergo significant structural alterations in immunocompetent mice, and this may represent a primer for papillary thyroid carcinoma (PTC) metastasis. © 2017 Wiley Periodicals, Inc.

  13. 'Brain drain' from Serbia: One face of globalization of education?

    Directory of Open Access Journals (Sweden)

    Avramović Zoran

    2012-01-01

    Full Text Available In this paper we point out the role of the practice and ideology of globalization in brain drain process from Serbia. The listed data are based on the large-scale departure of highly educated persons from Serbia to the counties of West Europe and the USA. The dynamics, proportions and tendencies are analysed the role of the educational system in the process of departure of highly educated people and the reasons and consequences of the departure of scientist and engineering experts. In this article, education policy as state financial support are critical analysed. For Serbia, as the relatively undeveloped country in the middle of the modernization processes, this process has far-reaching effects on the social development. So, here we implied the possible solutions for the problem of brain drain.

  14. Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.

    Science.gov (United States)

    Soufron, Jacques

    2015-10-01

    After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.

  15. Miniinvasive paracentetic drain surgical interventions under ultrasonic control concerning liquid formations of abdominal cavity

    Directory of Open Access Journals (Sweden)

    G.I. Ohrimenko

    2013-08-01

    Full Text Available Entry. Presently miniinvasive surgical interventions under ultrasonic control became the method of choice in treatment of quite a number of abdominal and retroperitoneal organs diseases, and their complications. These operations have a row of advantages, as compared to open and laparoscopic ones: comparative simplicity, insignificant infecting of abdominal region, least of intra- and postoperative complications. Actuality of problem is conditioned by that indications to the use of paracentetic drain surgical interventions, most optimal methods of preoperative diagnostic, features of postoperative treatment of patients remain not enough studied. Research aim. To study the results of diagnostics and treatment of patients with liquid formations of abdominal cavity that were exposed to miniinvasive surgical interventions under ultrasonic control and, on the basis of it, to work out an optimal curative diagnostic algorithm. Materials and research methods. The results of treatment of 25 patients with liquid formations of abdominal cavity are analyzed. They were submitted to miniinvasive paracentetic drain surgical interventions under ultrasonic control. The pseudocysts of pancreas were in 16 patients, abscesses of abdominal cavity – in 2 patients. Research results. Intraoperative complications were not marked. Postoperative complications were observed in 5 patients. Among them there were inadequate drainage of all cavities of multicamerate abscess of the liver in 2 patients, progress of sacculated uremic peritonitis developing in presence of ascites in one patient, and arrosive hemorrhage in the cavity of pancreas pseudocyst in 2 persons. It is determined that it is necessary to include the spiral computer tomography to the complex of preoperative inspection of patients that allows to diagnose multicamerate abscess of the liver in time and to drain all the additional cavities adequately. 2 patients after paracentetic drain surgical interventions

  16. Peat accumulation in drained thermokarst lake basins in continuous, ice-rich permafrost, northern Seward Peninsula, Alaska

    Science.gov (United States)

    Jones, Miriam C.; Grosse, Guido; Jones, Benjamin M.; Anthony, Katey Walter

    2012-01-01

    Thermokarst lakes and peat-accumulating drained lake basins cover a substantial portion of Arctic lowland landscapes, yet the role of thermokarst lake drainage and ensuing peat formation in landscape-scale carbon (C) budgets remains understudied. Here we use measurements of terrestrial peat thickness, bulk density, organic matter content, and basal radiocarbon age from permafrost cores, soil pits, and exposures in vegetated, drained lake basins to characterize regional lake drainage chronology, C accumulation rates, and the role of thermokarst-lake cycling in carbon dynamics throughout the Holocene on the northern Seward Peninsula, Alaska. Most detectable lake drainage events occurred within the last 4,000 years with the highest drainage frequency during the medieval climate anomaly. Peat accumulation rates were highest in young (50–500 years) drained lake basins (35.2 g C m−2 yr−1) and decreased exponentially with time since drainage to 9 g C m−2 yr−1 in the oldest basins. Spatial analyses of terrestrial peat depth, basal peat radiocarbon ages, basin geomorphology, and satellite-derived land surface properties (Normalized Difference Vegetation Index (NDVI); Minimum Noise Fraction (MNF)) from Landsat satellite data revealed significant relationships between peat thickness and mean basin NDVI or MNF. By upscaling observed relationships, we infer that drained thermokarst lake basins, covering 391 km2 (76%) of the 515 km2 study region, store 6.4–6.6 Tg organic C in drained lake basin terrestrial peat. Peat accumulation in drained lake basins likely serves to offset greenhouse gas release from thermokarst-impacted landscapes and should be incorporated in landscape-scale C budgets.

  17. 77 FR 30886 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Science.gov (United States)

    2012-05-24

    ... interpretation and installed unblockable drain covers and now would have to go back and ``re-do'' their work... compliance and whether the pool operator is seeking a plan review and not just limited advice about how to... secondary anti-entrapment system to come into compliance, unless the pool uses a gravity drain system or the...

  18. An analysis of molten-corium-induced failure of drain pipes in BWR Mark 2 containments

    International Nuclear Information System (INIS)

    Taleyarkhan, R.P.; Podowski, M.Z.

    1991-01-01

    This study has focused on mechanistic simulation and analysis of potential failure modes for inpedestal drywell drain pipes in the Limerick boiling water reactor (BWR) Mark 2 containment. Physical phenomena related to surface tension breakdown, heatup, melting, ablation, crust formation and failure, and core material relocation into drain pipes with simultaneous melting of pipe walls were modeled and analyzed. The results of analysis have been used to assess the possibility of drain pipe failure and the resultant loss of pressure-suppression capability. Estimates have been made for the timing and amount of molten corium released to the wetwell. The study has revealed that significantly different melt progression sequences can result depending upon the failure characteristics of the frozen metallic crust which forms over the drain cover during the initial stages of debris pour. Another important result is that it can take several days for the molten fuel to ablate the frozen metallic debris layer -- if the frozen layer has cooled below 1100 K before fuel attack. 10 refs., 3 figs., 4 tabs

  19. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  20. Should I stay or should I go? An institutional approach to brain drain

    OpenAIRE

    Cassar, Lea; Frey, Bruno S

    2010-01-01

    This paper suggests that institutional factors which reward social net- works at the expenses of productivity can play an important role in ex- plaining brain drain. The e€ects of social networks on brain drain are analyzed in a decision theory framework with asymmetric information. We distinguish between the role of insidership and personal connections. The larger the cost of being an outsider, the smaller is the number and the average ability of researchers working in the domestic job mar...

  1. Risk assessment of K basin twelve-inch drain valve failure from a postulated seismic initiating event

    International Nuclear Information System (INIS)

    MORGAN, R.G.

    1999-01-01

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rates which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations suggest that only the valve's bonnet and stem are exposed above the basin concrete floor. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this activity are to: (1) evaluate the risk of damaging the three twelve-inch drain valves located along the north wall of the main basin from a seismic initiating event, and (2) determine the associated potential leak rate from a damaged valve

  2. Risk assessment of K basin twelve-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-04-06

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rates which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations suggest that only the valve's bonnet and stem are exposed above the basin concrete floor. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this activity are to: (1) evaluate the risk of damaging the three twelve-inch drain valves located along the north wall of the main basin from a seismic initiating event, and (2) determine the associated potential leak rate from a damaged valve.

  3. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Mohsen Mirmohammad-Sadeghi

    2017-01-01

    Full Text Available Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001, but the trend of pain score between groups was not significantly different (P = 0.097. The frequency of tamponade and atrial fibrillation (AF were significantly lower in Jackson-Pratt drain group (P < 0.05. Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  4. Wound healing without drains in posterior spinal fusion in idiopathic scoliosis

    International Nuclear Information System (INIS)

    Alsiddiky, A.; Nisar, K.A.; Alhuzaimi, F.; Albishi, W.; Alnuaim, B.; Albarrag, M.; Meo, S.A.

    2013-01-01

    To determine the frequency of wound infection and neurological injuries in patients with idiopathic scoliosis who underwent posterior spinal fusion without use of drains. Study Design: Case series. Place and Duration of Study: Department of Orthopaedics, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia, from February 2007 to June 2010. Methodology: Patients who underwent similar technique of posterior spinal fusion instrumentation for the correction of scoliosis without use of drain were included. Wound Demographics, wound healing, complications and duration of hospital stay were considered and described as frequency and mean values. Results: The average age at the time of surgery was 12.80 +- 1.30 years, duration of surgery was 3.80 +- 0.86 hours, hospital stay was 3.84 +- 0.78 days and patients were followed-up over the last 30 months. There was no incidence of any neurological complication and deep infection. However, only 2 (4.16%) cases with superficial skin infection were treated with dressing and antibiotics with full recovery. Conclusion: The wound healing is adequate without using drain for patients with idiopathic scoliosis who underwent posterior spinal fusion and instrumentation when good wash, watertight closure technique and appropriate antibiotics coverage is provided. (author)

  5. Short-channel drain current model for asymmetric heavily/lightly ...

    Indian Academy of Sciences (India)

    The paper presents a drain current model for double gate metal oxide semiconductor field effect transistors (DG MOSFETs) based on a new velocity saturation model that accounts for short-channel velocity saturation effect independently in the front and the back gate controlled channels under asymmetric front and back ...

  6. Design and construction of a French drain for groundwater diversion in solid waste storage area six at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Davis, E.C.; Stansfield, R.G.

    1984-05-01

    Engineering modifiations or engineered barriers have been suggested as a possible means of improving the performance of low-level waste disposal sites located in the humid eastern United States. Design and construction of a passive French drain, located in Solid Waste Storage Area No. 6 at the Oak Ridge National Laboratory. The drain was designed to hydrologically isolate a 0.44-ha area that contains a group of 49 low-level waste trenches by separating it from upgradient groundwater recharge areas. The 252-m drain (maximum depth = 9 m) that surrounds the group of trenches on the north and east sides was excavated, lined with filter fabric, backfilled with crushed stone, and covered with a 0.6 m layer of excavated material at an estimated cost of $153,000. Of the 17 days it took to complete the work, about 5 days were spent excavating sidewall slide material that fell into the drain during excavation. Photography of the drain wall revealed the contorted structure of the weathered shale, which was responsible for many of the slides. Monitoring wells placed at intervals on the drain centerline indicate that groundwater is draining from the surrounding Maryville Formation (Conasauga Group); flows at catch basin No. 2 ranged from a base flow of 4 to 7 L/min to a maximum of 35 L/min, recorded on October 13. In response to groundwater flow in the drain, water levels in several monitoring wells adjacent to the drain have dropped by as much as 2.24 m to an elevation only slightly higher than the bottom of the French drain. In addition to the general lowering of the water table in the vicinity of the drain, water levels in three trenches began to subside, indicating that the drain is beginning to have an effect on the water in the trenches as well. Further monitoring of both drain discharge and water levels in monitoring wells across the site is continuing

  7. Drained Triaxial Tests on Eastern Scheldt Sand

    DEFF Research Database (Denmark)

    Praastrup, U.; Jakobsen, Kim Parsberg

    In the process of understanding and developing models for geomaterials, the stress-strain behaviour is commonly studied by performing triaxial tests. In the present study static triaxial tests have been performed to gain knowledge of the stress-strain behaviour of frictional materials during...... monotonic loading. The tests reported herein are all drained tests, starting from different initial states of stress and following various stress paths. AIl the tests are performed on reconstituted medium dense specimens of Eastern Scheldt Sand....

  8. Water Table Recession in Subsurface Drained Soils

    OpenAIRE

    Moustafa, Mahmoud Mohamed; Yomota, Atsushi

    1999-01-01

    Theoretical drainage equations are intensively tested in many parts of humid and arid regions and are commonly used in drainage design. However, this is still a great concern in Japan as the drainage design is exclusively based on local experiences and empirical basis. There is a need therefore to evaluate the theoretical drainage equations under Japanese field conditions to recommend equations for design of subsurface drainage systems. This was the main motivation for this study. While drain...

  9. No-Drain Single Incision Liposuction Pull-Through Technique for Gynecomastia.

    Science.gov (United States)

    Khalil, Ashraf A; Ibrahim, Amr; Afifi, Ahmed M

    2017-04-01

    Several different methods have been proposed for treatment of gynecomastia, depending on the amount of breast enlargement and skin redundancy. The liposuction pull-through technique has been proposed as an efficacious treatment for many gynecomastia cases. This work aims to study the outcome of this technique when applied as an outpatient procedure, without the use of drains and through a single incision. Fifty-two patients with bilateral gynecomastia without significant skin excess were included in this study. The liposuction pull-through technique was performed through a single incision just above the inframammary fold and without the use of drains. Patients were followed up for 6 months. The proposed technique was able to treat the gynecomastia in all patients, with a revision rate of 1.9% to remove residual glandular tissues. There were no seromas, hematomas, nipple distortion, permanent affection of nipple sensation or wound healing problems. The liposuction pull-through technique is an effective treatment for gynecomastia without significant skin redundancy. It combines the benefits of the direct excision of glandular tissues, with the minimally invasive nature of liposuction. Performing the procedure through a single incision without the use of drains and without general anesthesia is a safe alternative. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266 .

  10. Theoretical computation background for transformation of foundations using pile drains

    Directory of Open Access Journals (Sweden)

    Ter-Martirosyan Zaven

    2017-01-01

    Full Text Available In the design of foundations for buildings and structures of various purposes, including improved risk, weak water-saturated clay soils with low mechanical characteristics are often found on a construction site. One of the possible ways of using them as a foundation is to seal them in various ways, including using pile drains of sand or rock stone material that are capable of both absorbing the load at the base and accelerating the process of filtration consolidation. This paper describes an analytical solution to the problem of interaction between the pile and the mattress with the surrounding soil of the foundation, taking into account the possibility of expanding the pile shaft. Solutions are obtained for determining the stresses in the shaft of the pile drain and in the soil under the mattress. The solution takes into account the influence of the pre-stressed state of the foundation after compaction on the formation of a stress-strain state during the erection and operation of structures. The solutions are relevant for consolidating pile drains made of rubble or for jet grouting piles, the rigidity of which is comparable to the rigidity of the surrounding soil. The paper describes the technique for determining the characteristics of the strength and deformability of the converted foundation and the results of large-scale tests at the experimental site for the construction of a large energy facility in Russia.

  11. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Science.gov (United States)

    2010-07-01

    ... restricts wind motion across the open area between the pipe and the drain) that encloses the space between...., there is no pump) or is operated with no more than slight fluctuations in the liquid level, the owner or...

  12. Thermal-fluid analysis of the fill and drain operations of a cryrogenic fuel tank

    Science.gov (United States)

    Stephens, Craig A.; Hanna, Gregory J.; Gong, Leslie

    1993-01-01

    The Generic Research Cryogenic Tank was designed to establish techniques for testing and analyzing the behavior of reusable fuel tank structures subjected to cryogenic fuels and aerodynamic heating. The Generic Research Cryogenic Tank tests will consist of filling a pressure vessel to a prescribed fill level, waiting for steady-state conditions, then draining the liquid while heating the external surface to simulate the thermal environment associated with hypersonic flight. Initial tests of the Generic Research Cryogenic Tank will use liquid nitrogen with future tests requiring liquid hydrogen. Two-dimensional finite-difference thermal-fluid models were developed for analyzing the behavior of the Generic Research Cryogenic Tank during fill and drain operations. The development and results of the two-dimensional fill and drain models, using liquid nitrogen, are provided, along with results and discussion on extrapolating the model results to the operation of the full-size Generic Research Cryogenic Tank. These numerical models provided a means to predict the behavior of the Generic Research Cryogenic Tank during testing and to define the requirements for the Generic Research Cryogenic Tank support systems such as vent, drain, pressurization, and instrumentation systems. In addition, the fill model provided insight into the unexpected role of circumferential conduction in cooling the Generic Research Cryogenic Tank pressure vessel during fill operations.

  13. An Improvised Active Drain | Ogirima | Nigerian Journal of Surgical ...

    African Journals Online (AJOL)

    An improvised active drain is designed from intravenous infusion set and recycled RedivacR or Haemovac® bottle. Outcome of the use of this system on 100 patients is presented. This suction drainage system had been used in major orthopaedic and common minor surgical procedures and no significant complication was ...

  14. On the use of drains in orthopedic and trauma

    African Journals Online (AJOL)

    2013-11-08

    Nov 8, 2013 ... Even major procedures like total knee and arthroplasties are being performed without drains. We set to find ... discourage wound healing while encouraging bacterial ... a period of two days or if drainage over the first twenty‑four hours was found ... Three of the twenty Kuntscher nailings for femoral fracture.

  15. DETERMINATION OF LIQUID FILM THICKNESS FOLLOWING DRAINING OF CONTACTORS, VESSELS, AND PIPES IN THE MCU PROCESS

    International Nuclear Information System (INIS)

    Poirier, M; Fernando Fondeur, F; Samuel Fink, S

    2006-01-01

    The Department of Energy (DOE) identified the caustic side solvent extraction (CSSX) process as the preferred technology to remove cesium from radioactive waste solutions at the Savannah River Site (SRS). As a result, Washington Savannah River Company (WSRC) began designing and building a Modular CSSX Unit (MCU) in the SRS tank farm to process liquid waste for an interim period until the Salt Waste Processing Facility (SWPF) begins operations. Both the solvent and the strip effluent streams could contain high concentrations of cesium which must be removed from the contactors, process tanks, and piping prior to performing contactor maintenance. When these vessels are drained, thin films or drops will remain on the equipment walls. Following draining, the vessels will be flushed with water and drained to remove the flush water. The draining reduces the cesium concentration in the vessels by reducing the volume of cesium-containing material. The flushing, and subsequent draining, reduces the cesium in the vessels by diluting the cesium that remains in the film or drops on the vessel walls. MCU personnel requested that Savannah River National Laboratory (SRNL) researchers conduct a literature search to identify models to calculate the thickness of the liquid films remaining in the contactors, process tanks, and piping following draining of salt solution, solvent, and strip solution. The conclusions from this work are: (1) The predicted film thickness of the strip effluent is 0.010 mm on vertical walls, 0.57 mm on horizontal walls and 0.081 mm in horizontal pipes. (2) The predicted film thickness of the salt solution is 0.015 mm on vertical walls, 0.74 mm on horizontal walls, and 0.106 mm in horizontal pipes. (3) The predicted film thickness of the solvent is 0.022 mm on vertical walls, 0.91 mm on horizontal walls, and 0.13 mm in horizontal pipes. (4) The calculated film volume following draining is: (a) Salt solution receipt tank--1.6 gallons; (b) Salt solution feed

  16. Systematic review and meta-analysis of wound drains after thyroid surgery.

    LENUS (Irish Health Repository)

    Woods, R S R

    2014-04-01

    Drainage after routine thyroid and parathyroid surgery remains controversial. However, there is increasing evidence from a number of randomized clinical trials (RCTs) suggesting no benefit from the use of drains.

  17. Brain drain and health workforce distortions in Mozambique.

    Science.gov (United States)

    Sherr, Kenneth; Mussa, Antonio; Chilundo, Baltazar; Gimbel, Sarah; Pfeiffer, James; Hagopian, Amy; Gloyd, Stephen

    2012-01-01

    Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs), and the private sector. An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties. Of 723 qualifying physicians between 1980-2006, 95.9% (693) were working full-time, including 71.1% (493) as clinicians, 20.5% (142) as health system managers, and 6.9% (48) as researchers/professors. 25.5% (181) of the sample had left the public sector, of which 62.4% (113) continued working in-country and 37.6% (68) emigrated from Mozambique. Of those cases of internal migration, 66.4% (75) worked for NGOs, 21.2% (24) for donor agencies, and 12.4% (14) in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113) of internal migration cases had previously held senior-level management positions in the public sector. Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they seek

  18. India: 'brain drain' or the migration of talent?

    Science.gov (United States)

    Oommen, T K

    1989-09-01

    2 views on "brain drain" exist: 1) LDCs lose their enormous investments on higher education when skilled people migrate to other countries and 2) LDCs are exaggerating the problem and only a few skilled people migrate at 1 time. India does not completely lose its investment in education when professionals migrate, since the migrants still contribute to knowledge and also send remittances to relatives in India. Unemployed educated people would cause a greater drain on India's resources than educated migrants. The author prefers the phrase migration of talent to brain drain, since the former indicates a 2-way movement. Most migrants from LDCs are students. About 11,000 university graduates leave India every year for advanced study and/or work. A conservative estimate is that 2500 will remain abroad permanently. Most professionals who migrate go to the US and Canada. Factors promoting migration include 1) unemployment, 2) immigration rules, 3) colonial links, 4) financial incentives and material benefits, 5) pursuit of higher education, 6) improvement of working conditions and facilities, 7) avoidance of excessive bureaucratic procedures, and 8) compensation for the mismatch between Indian education and employment. Reasons for returning to India include 1) deference to wives who were unable to adjust to a foreign way of life, 2) contributing to Indian development, and 3) racial discrimination. It will probably not be possible to lure back migrants who left for material reasons. Attractive job offers could entice back those who left for advanced training. To encourage the return of those who left to pursue high quality research, India must 1) increase expenditure on research and development, possibly through the private industrial sector, 2) promote travel to other countries for professional enrichment, and 3) improve conditions of research work. The article concludes with an analysis of migration of talent from 3 perspectives: 1) the individual, 2) the nation

  19. Brain drain and health workforce distortions in Mozambique.

    Directory of Open Access Journals (Sweden)

    Kenneth Sherr

    Full Text Available Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs, and the private sector.An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties.Of 723 qualifying physicians between 1980-2006, 95.9% (693 were working full-time, including 71.1% (493 as clinicians, 20.5% (142 as health system managers, and 6.9% (48 as researchers/professors. 25.5% (181 of the sample had left the public sector, of which 62.4% (113 continued working in-country and 37.6% (68 emigrated from Mozambique. Of those cases of internal migration, 66.4% (75 worked for NGOs, 21.2% (24 for donor agencies, and 12.4% (14 in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113 of internal migration cases had previously held senior-level management positions in the public sector.Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they

  20. Remote sensing for assessing the zone of benefit where deep drains improve productivity of land affected by shallow saline groundwater.

    Science.gov (United States)

    Kobryn, H T; Lantzke, R; Bell, R; Admiraal, R

    2015-03-01

    The installation of deep drains is an engineering approach to remediate land salinised by the influence of shallow groundwater. It is a costly treatment and its economic viability is, in part, dependent on the lateral extent to which the drain increases biological productivity by lowering water tables and soil salinity (referred to as the drains' zone of benefit). Such zones may be determined by assessing the biological productivity response of adjacent vegetation over time. We tested a multi-temporal satellite remote sensing method to analyse temporal and spatial changes in vegetation condition surrounding deep drainage sites at five locations in the Western Australian wheatbelt affected by dryland salinity-Morawa, Pithara, Beacon, Narembeen and Dumbleyung. Vegetation condition as a surrogate for biological productivity was assessed by Normalised Difference Vegetation Index (NDVI) during the peak growing season. Analysis was at the site scale within a 1000 m buffer zone from the drains. There was clear evidence of NDVI increasing with elevation, slope and distance from the drain. After accounting for elevation, slope and distance from the drain, there was a significant increase in NDVI across the five locations after installation of deep drains. Changes in NDVI after drainage were broadly consistent with measured changes at each site in groundwater levels after installation of the deep drains. However, this study assessed the lateral extent of benefit for biological productivity and gave a measure of the area of benefit along the entire length of the drain. The method demonstrated the utility of spring NDVI images for rapid and relatively simple assessment of the change in site condition after implementation of drainage, but approaches for further improvement of the procedure were identified. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. A COMPARATIVE STUDY IN HERNIOPLASTY WITH AND WITHOUT DRAIN AND THE ASSOCIATED COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Amruthavalli Bayya Venkatesulu

    2017-03-01

    Full Text Available BACKGROUND The present study is a comparative study to compare in Lichtenstein’s mesh repair, the need of a subcutaneous suction drain in inguinal hernias at Government General Hospital, Guntur. To study the advantages and disadvantages of using subcutaneous suction drain in Lichtenstein’s hernioplasty. MATERIALS AND METHODS In the present study, out of 50 patients,32% of patients who had undergone drainage group complained of pain and 8% of patients who had undergone non-drainage complained of pain. In our study, 0% and 4% of patients developed haematoma in drainage and non-drainage group, respectively. 12% of patients in drainage group developed seroma and 12% of patients in non-drainage group developed seroma. In the present study, 16% of cases in drainage and 20% in non-drainage group. In the present study, patients in drainage group mean postoperative hospital stay is 9.1 days and in non-drainage group is 6.7 days. The average duration of postoperative hospital stay in patients of drainage group is higher than in non-drainage group with the above results, the early postoperative complications like pain, mean postoperative stay in hospital are increased in Lichtenstein’s with drainage group. The early postoperative complications like seroma, haematoma and wound infection rates are similar in both drainage and non-drainage groups. So, it appears that suction drain usage can be restricted in Lichtenstein’s tension free mesh repair in simple inguinal hernias unless the hernia is complicated or there is extensive dissection. RESULTS The details of all the (50 cases were drawn as master chart with regard of relevance. Statistical analysis was done using Epi info version 3.5.3. P value is calculated using Chi-square test. CONCLUSION In the present study, 50 patients with inguinal hernia who had undergone Lichtenstein’s hernioplasty with subcutaneous suction drain are compared with those who had undergone Lichtenstein’s hernioplasty

  2. A novel gate and drain engineered charge plasma tunnel field-effect transistor for low sub-threshold swing and ambipolar nature

    Science.gov (United States)

    Yadav, Dharmendra Singh; Raad, Bhagwan Ram; Sharma, Dheeraj

    2016-12-01

    In this paper, we focus on the improvement of figures of merit for charge plasma based tunnel field-effect transistor (TFET) in terms of ON-state current, threshold voltage, sub-threshold swing, ambipolar nature, and gate to drain capacitance which provides better channel controlling of the device with improved high frequency response at ultra-low supply voltages. Regarding this, we simultaneously employ work function engineering on the drain and gate electrode of the charge plasma TFET. The use of gate work function engineering modulates the barrier on the source/channel interface leads to improvement in the ON-state current, threshold voltage, and sub-threshold swing. Apart from this, for the first time use of work function engineering on the drain electrode increases the tunneling barrier for the flow of holes on the drain/channel interface, it results into suppression of ambipolar behavior. The lowering of gate to drain capacitance therefore enhanced high frequency parameters. Whereas, the presence of dual work functionality at the gate electrode and over the drain region improves the overall performance of the charge plasma based TFET.

  3. Laparoscopic primary repair and isoperistaltic endoluminal drain for Boerhaave's Syndrome.

    Science.gov (United States)

    Prete, Francesco; Pezzolla, Angela; Nitti, Paolo; Prete, Fernando

    2015-01-01

    Spontaneous oesophageal rupture, also known as Boerhaave syndrome (BS), is a rare and potentially lethal pathological condition. BS recognition is difficult, while rapidity of diagnosis, along with extension of the lesion, affects type and outcome of treatment. BS was classically treated by thoracotomy, but laparoscopic (LS), thoracoscopic (TS) surgery, and nonsurgical procedures as endoscopic stent positioning or use of glues have been described. Still, there is no model treatment, and selection of the most appropriate therapeutic procedure is complex in the absence of standardised criteria. We successfully managed a patient affected with BS by LS approach and present our experience along with a review of treatment options so far described. Our treatment integrated positioning of an oesophageal isoperistaltic endoluminal drain (IED), that we routinely use in oesophageal sutures at risk of leakage, and of which there is no previous report in the setting of BS. A 68 year old man presented to our attention with true BS, suspected on chest-abdominal CT scan and confirmed by upper GI contrast swallow test, showing leakage of hydro-soluble contrast from the lower third of the oesophagus. Of note, pleural cavities appeared intact. We performed an urgent laparoscopy 12 hours after the onset of symptoms. Laparoscopic toilet of the inferior mediastinum and dual layer oesophageal repair with pedicled omental flap were complemented by positioning of IED, feeding jejunostomy and two tubular drains. The patient had a slow but consistent recovery where IED played as a means of oesophageal suture protection, until he could be discharged home. We think that, when integrity of the pleura is documented, LS should be priority choice to avoid contamination of the pleural cavities. We have to consider every type of oesophageal repair in BS at risk of failure, and every means of protection of the suture is opportune. In our patient the oesophageal suture, covered with a flap of omentum

  4. Effect of One versus Two Drain Insertion on Postoperative Seroma Formation after Modified Radical Mastectomy

    Directory of Open Access Journals (Sweden)

    farzaneh ebrahimifard

    2016-04-01

    Full Text Available Background: Modified radical mastectomy (MRM is still one of globally accepted surgical techniques for breast cancer and in some selected patient is the gold standard type of surgery. The most frequent complication of this procedure is seroma under skin flaps or in the axilla as reported as much as 30% in some studies. The use of closed suction drainage system to reduce the incidence of this complication has been routinely accepted by surgeons; however, length of catheter stay and the number of catheters inserted in the wound are still controversial. The present study compares the results of single versus double drain insertion in patients undergoing MRM for breast cancer.Materials and Methods: The study was conducted on 100 women with breast cancer who were candidate for MRM surgery during 2007-2010 referred to Modarres hospital, Tehran, Iran as a randomized group matched controlled trial.Results: There was no significant difference between the two groups in terms of age, BMI, and tumor weight (P=0.406 (Table 1. Similarly, the difference between the two groups was insignificant in tumor size (T and number of lymph nodes involved (P=0.145. There was no significant difference between the two groups in timing of axillary drain removal (P=0.064. No significant differences were observed between the two groups in mean aspirated fluid (P=0.071 and mean aspirated sera (P=0.484 after removal of drains.Conclusion: This study revealed one drain insertion in MRM surgery is as effective as two drain and probably less morbidity and cost.

  5. Indwelling pleural drain for mobile management of malignant pleural effusion-combining benefits of both methods

    OpenAIRE

    Dinesh Mehta; Anshu Gupta; Sameer Singhal; Sachin Bansal

    2015-01-01

    Malignant pleural effusion is a leading cause of morbidity in lung cancer patients requiring repeated pleural aspirations or persistent intercostal drainage tube. Using an indigenous method of putting icd tube of smaller size with subcutaneous tunneling would allow draining fluid from lungs easily and painlessly when needed and avoid the need for repeated injections and chest tube insertion every time the fluid is to be drained.

  6. Spatial and temporal distribution of mosquitoes in underground storm drain systems in Orange County, California.

    Science.gov (United States)

    Su, Tianyun; Webb, James P; Meyer, Richard P; Mulla, Mir S

    2003-06-01

    Underground storm drain systems in urban areas of Orange County include thousands of miles of gutters and underground pipelines, plus hundreds of thousands of catch basins and manhole chambers, all of which drain runoff water from residential, business and commercial establishments as well as highways and streets. These systems serve as major developmental and resting sites for anthropophilic and zoophilic mosquitoes. Investigations on spatial and temporal distribution of mosquitoes in these systems were conducted during November 1999 to October 2001. Immature mosquitoes were sampled by dipper or dipping net and adult mosquitoes by non-attractive CDC traps in manhole chambers, catch basins and a large drain. Culex quinquefasciatus Say prevailed at all 15 structures of the study in 4 cities of Orange County as the predominant species (> 99.9%). Larvae and pupae were present from April to October, peaking from May to September. The population density of adults was the lowest in February with 2 peaks of abundance occurring from May to July and from September to October. Manhole chambers and catch basins harbored more mosquitoes than did the large drain. Minimum and maximum temperatures during a 24 h sampling period was an important factor influencing adult mosquito activity and catches; more mosquitoes were caught in traps when it was warmer, especially when the minimum temperatures were higher. The proportion of females to males in general increased during winter and early spring an ddeclined during summer. The proportion of gravid females to empty females was higher during the winter than in summer. Other dipteran taxa such as psychodid moth flies and chironomid midges exhibited somewhat similar seasonal patterns as did mosquito populations. Average water temperature was relatively stable throughout the year, and water quality in underground drain systems was characterized by low dissolved oxygen, coupled with above normal electrical conductivity and salinity levels

  7. Brain Drain in Higher Education: Lost Hope or Opportunity?

    Science.gov (United States)

    Odhiambo, George

    2012-01-01

    The flight of human capital is a phenomenon that has been of concern to academics and development practitioners for decades but unfortunately, there is no systematic record of the number of skilled professionals that many African countries have continued to lose to the developed world. Termed the "brain drain", it represents the loss of…

  8. The Treatment Of The RSU In Controlled Drains: Their Sanitary Problem To The Production Of Energy

    International Nuclear Information System (INIS)

    Calderon U, Rafael A.

    1995-01-01

    The limitless world production of residuals generates constant concerns with relationship to its administration. The classic elimination methods as the drains controlled in front of the controversial incineration plants and gasification as well as the expectations created around the recycle practices, are reason of intense debates among city councils, specialist, environmentalist technicians and the public in general. The certain thing is that the residuals in the last 30 years have been valued economically. Today in day the residuals are appreciated by certain sectors that begin to monopolize the line of the recycle because they come them an excellent business. All the methods of elimination of residuals produce in turn others. Those of solid nature in general go to the drain, the semi-liquids becomes dehydrated for the same end. Presently work, without seeking to say that the employment of the drains is the best option, thinks about how it has more than enough they are possible to optimize its use. Showing beside their eminently sanitary vocation an energy alternative that allows the use of the combustible gas that is generated in them. An added value that is interesting if this it becomes source of well-being for social excluded nuclei and economically like it happens for example in the peripheries of the drains of the big Latin American cities. They are considered which are the main aspects that intervene in the generation, production and quality of the gas methane of the drains. Their reception methods and their use alternatives. Lastly emphasis is made in the environmental situation to European and international level about the gases of the drain, how it thinks about the topic of the greenhouse effect and which are the actions for the horizon of the year 2000. They are related some experiences in Europe on the use of the biogas

  9. Analyzing subsurface drain network performance in an agricultural monitoring site with a three-dimensional hydrological model

    Science.gov (United States)

    Nousiainen, Riikka; Warsta, Lassi; Turunen, Mika; Huitu, Hanna; Koivusalo, Harri; Pesonen, Liisa

    2015-10-01

    Effectiveness of a subsurface drainage system decreases with time, leading to a need to restore the drainage efficiency by installing new drain pipes in problem areas. The drainage performance of the resulting system varies spatially and complicates runoff and nutrient load generation within the fields. We presented a method to estimate the drainage performance of a heterogeneous subsurface drainage system by simulating the area with the three-dimensional hydrological FLUSH model. A GIS analysis was used to delineate the surface runoff contributing area in the field. We applied the method to reproduce the water balance and to investigate the effectiveness of a subsurface drainage network of a clayey field located in southern Finland. The subsurface drainage system was originally installed in the area in 1971 and the drainage efficiency was improved in 1995 and 2005 by installing new drains. FLUSH was calibrated against total runoff and drain discharge data from 2010 to 2011 and validated against total runoff in 2012. The model supported quantification of runoff fractions via the three installed drainage networks. Model realisations were produced to investigate the extent of the runoff contributing areas and the effect of the drainage parameters on subsurface drain discharge. The analysis showed that better model performance was achieved when the efficiency of the oldest drainage network (installed in 1971) was decreased. Our analysis method can reveal the drainage system performance but not the reason for the deterioration of the drainage performance. Tillage layer runoff from the field was originally computed by subtracting drain discharge from the total runoff. The drains installed in 1995 bypass the measurement system, which renders the tillage layer runoff calculation procedure invalid after 1995. Therefore, this article suggests use of a local correction coefficient based on the simulations for further research utilizing data from the study area.

  10. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    Directory of Open Access Journals (Sweden)

    Xiao Guo

    2014-01-01

    Full Text Available This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1 the flow with the threshold gradient would not occur instantaneously throughout the whole unit cell. Rather, it gradually occurs from the vertical drain to the outside; (2 the moving boundary would never reach the outer radius of influence if R+1

  11. Effect of Needle Aspiration of Pneumothorax on Subsequent Chest Drain Insertion in Newborns

    DEFF Research Database (Denmark)

    Murphy, Madeleine C; Heiring, Christian; Doglioni, Nicoletta

    2018-01-01

    Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating pneumotho......Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating...... was 5 tertiary European neonatal intensive care units. Infants receiving respiratory support (endotracheal ventilation, continuous positive airway pressure, or supplemental oxygen >40%) who had a pneumothorax on CR that clinicians deemed needed treatment were eligible for inclusion. Interventions...... was inserted if clinicians deemed that the response was inadequate. For CD insertion, a drain was inserted between the ribs and was left in situ. Main Outcomes and Measures: The primary outcome was whether a CD was inserted on the side of the pneumothorax within 6 hours of diagnosis. Results: A total of 76...

  12. The project of the technological line of the electronic-beam drains disinfection in the infected hospitals' divisions and tubercular centres

    International Nuclear Information System (INIS)

    Shlapatska, V.V.; Volkonsky, V.G.; Sakhno, V.I.; Tomchaj, S.P.

    1999-01-01

    The purpose of the project was to create the electrophysical facility for the environmental protection from contamination by drains of the infected hospitals' divisions and tubercular centres and prevention of open water reservoirs. Development of the economically approved methods of the radiative disinfection of contaminated drains; development of the inexpensive compact facility for the electron-beam disinfection of small volume drains

  13. Moving Policy Forward: "Brain Drain" as a Wicked Problem

    Science.gov (United States)

    Logue, Danielle

    2009-01-01

    The mobility of scientists and the concerns surrounding "brain drain" are not new. Even in the Ptolemic dynasty, the first king set out to attract and influence the movements of scholars to shift the centre of learning from Athens to Alexandria. Yet after all this time, there is still much policy discourse and debate focused on attempting to…

  14. Brain drain from developing countries: how can brain drain be converted into wisdom gain?

    Science.gov (United States)

    Dodani, Sunita; LaPorte, Ronald E

    2005-01-01

    Brain drain is defined as the migration of health personnel in search of the better standard of living and quality of life, higher salaries, access to advanced technology and more stable political conditions in different places worldwide. This migration of health professionals for better opportunities, both within countries and across international borders, is of growing concern worldwide because of its impact on health systems in developing countries. Why do talented people leave their countries and go abroad? What are the consequences of such migrations especially on the educational sector? What policies can be adopted to stem such movements from developing countries to developed countries? This article seeks to raise questions, identify key issues and provide solutions which would enable immigrant health professionals to share their knowledge, skills and innovative capacities and thereby enhancing the economic development of their countries. PMID:16260795

  15. Conjunctivodacryocystorhinostomy using a high-density porous polyethylene-coated tear drain tube.

    Science.gov (United States)

    Pushker, Neelam; Khurana, Saurbhi; Shrey, Dinesh; Bajaj, Mandeep S; Chawla, Bhavna; Chandra, Mahesh

    2013-08-01

    To evaluate the outcome of conjunctivodacryocystorhinostomy using a high-density porous polyethylene (HDPP)-coated tear drain tube. Patients with epiphora due to a proximal lacrimal system block were included in a prospective interventional case study. A total of 22 eyes were treated with lacrimal bypass surgery using the HDPP-coated tube. On follow-up (12-41 months), 21 eyes had a patent well-positioned tube with subjective relief of epiphora. In one eye, a loose sleeve was noted during surgery. The tube dislodged postoperatively and was removed. A high success rate with only a few minor complications is achievable using a HDPP-coated tear drain tube for lacrimal bypass surgery. Long-term follow-up is required to look for tube blockage due to conjunctival or nasal mucosal overgrowth.

  16. Pontine infarction caused by medial branch injury of the basilar artery as a rare complication of cisternal drain placement

    OpenAIRE

    Horiuchi, Tetsuyoshi; Yamamoto, Yasunaga; Kuroiwa, Masafumi; Rahmah, Nunung Nur; Hongo, Kazuhiro

    2012-01-01

    We present a rare complication of cisternal drain placement during aneurysm surgery. A ruptured anterior communicating artery aneurysm was clipped through a right pterional approach. A cisternal drain was inserted from the retro-carotid to the prepontine cistern. Postoperatively, a left-sided paresis of the upper extremity had developed. A CT brain scan revealed that the drain was located between the pons and the basilar artery, resulting in a pontine infarction. Vascular neurosurgeons should...

  17. Indwelling pleural drain for mobile management of malignant pleural effusion-combining benefits of both methods

    Directory of Open Access Journals (Sweden)

    Dinesh Mehta

    2015-01-01

    Full Text Available Malignant pleural effusion is a leading cause of morbidity in lung cancer patients requiring repeated pleural aspirations or persistent intercostal drainage tube. Using an indigenous method of putting icd tube of smaller size with subcutaneous tunneling would allow draining fluid from lungs easily and painlessly when needed and avoid the need for repeated injections and chest tube insertion every time the fluid is to be drained.

  18. Modeling and risk assessment of a 30-Year-old subsurface radioactive-liquid drain field

    Science.gov (United States)

    Dawson, Lon A.; Pohl, Phillip I.

    1997-11-01

    The contamination from a 30-year-old radioactive liquid drain field was assessed for movement in the subsurface and potential risks to humans. This assessment included determining field concentrations of cesium 137 (137Cs) and other inorganic contaminants and modeling of the flow and transport of the liquid waste that was sent to the drain field. The field investigation detected no contamination deeper than 15 feet (4.6 m) from the bottom of the drain field. Prediction of the water content of the vadose zone showed no saturated conditions for times greater than 10 years after the known infiltration. Sensitivity analysis of the modeling parameters showed the equilibrium sorption coefficient to be the most important factor in predicting the contaminant plumes. Calibration of modeling results with field data gave a 137Cs sorption coefficient that is within the range of values found in the literature. The risk assessment for the site showed that the contamination poses no significant risk to human health.

  19. The association between soluble intercellular adhesion molecule-1 levels in drained dialysate and peritoneal injury in peritoneal dialysis.

    Science.gov (United States)

    Igarashi, Yusuke; Morishita, Yoshiyuki; Yoshizawa, Hiromichi; Imai, Reika; Imai, Toshimi; Hirahara, Ichiro; Akimoto, Tetsu; Ookawara, Susumu; Ishibashi, Kenichi; Muto, Shigeaki; Nagata, Daisuke

    2017-11-01

    Chronic inflammation of the peritoneum causes peritoneal injury in patients on peritoneal dialysis. Intercellular adhesion molecule-1 and its circulating form, soluble intercellular adhesion molecule-1, play pivotal roles in inflammation. However, their role in peritoneal injury is unclear. We measured changes in intercellular adhesion molecule-1 expression in the peritoneum of a peritoneal injury model in rats. The associations between soluble intercellular adhesion molecule-1 levels in drained dialysate and the solute transport rate (D/P-Cr and D/D0-glucose) determined by the peritoneal equilibration test, and matrix metalloproteinase-2 levels in drained dialysate were investigated in 94 peritoneal drained dialysate samples. Intercellular adhesion molecule-1 expression was increased in the peritoneum of rats with peritoneal injury. Soluble intercellular adhesion molecule-1 levels in drained dialysate were significantly positively correlated with D/P-Cr (r = .51, p molecule-1expression is increased in the peritoneum of a peritoneal injury model in the rat, and soluble intercellular adhesion molecule-1 levels in drained dialysate are associated with peritoneal injury in patients on peritoneal dialysis. These results suggest that soluble intercellular adhesion molecule-1 could be a novel biomarker of peritoneal injury in patients on peritoneal dialysis.

  20. Case Report: Supernumerary right renal vein draining inferior to the ...

    African Journals Online (AJOL)

    With recent increase in renal transplantations, renovascular reconstructions and imaging advances, meticulous knowledge of the normal and variant anatomy of the renal vasculature is important to avoid potential pitfalls. We report a case of an accessory renal vein arising from the right kidney, and draining into the inferior ...

  1. Influence of Hudiara Drain Water Irrigation on Trace Elements Load ...

    African Journals Online (AJOL)

    ... Drain Water Irrigation on Trace Elements Load In Soil And Uptake By Vegetables. ... This polluted water not only contains organic matter and crop nutrients but also ... Plant samples were collected at maturity from all the monitoring points. ... (DO), Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD) ...

  2. A prospective randomised study to compare the utility and outcomes of subdural and subperiosteal drains for the treatment of chronic subdural haematoma.

    LENUS (Irish Health Repository)

    Kaliaperumal, Chandrasekaran

    2012-11-01

    The usage of a drain following evacuation of a chronic subdural haematoma (CSDH) is known to reduce recurrence. In this study we aim to compare the clinical outcomes and recurrence rate of utilising two different types of drains (subperiosteal and subdural drain) following drainage of a CSDH.

  3. The effect of random dopant fluctuation on threshold voltage and drain current variation in junctionless nanotransistors

    International Nuclear Information System (INIS)

    Rezapour, Arash; Rezapour, Pegah

    2015-01-01

    We investigate the effect of dopant random fluctuation on threshold voltage and drain current variation in a two-gate nanoscale transistor. We used a quantum-corrected technology computer aided design simulation to run the simulation (10000 randomizations). With this simulation, we could study the effects of varying the dimensions (length and width), and thicknesses of oxide and dopant factors of a transistor on the threshold voltage and drain current in subthreshold region (off) and overthreshold (on). It was found that in the subthreshold region the variability of the drain current and threshold voltage is relatively fixed while in the overthreshold region the variability of the threshold voltage and drain current decreases remarkably, despite the slight reduction of gate voltage diffusion (compared with that of the subthreshold). These results have been interpreted by using previously reported models for threshold current variability, load displacement, and simple analytical calculations. Scaling analysis shows that the variability of the characteristics of this semiconductor increases as the effects of the short channel increases. Therefore, with a slight increase of length and a reduction of width, oxide thickness, and dopant factor, we could correct the effect of the short channel. (paper)

  4. Investigation of radiation safety management at nuclear medicine facilities in Japan. Contamination of radioactivity in the draining-water system

    International Nuclear Information System (INIS)

    Endo, Keigo; Koizumi, Mitsuru; Kinoshita, Fujimi; Nakazawa, Keiji

    1999-01-01

    Radiation-safety management condition in Japanese nuclear medicine facilities were investigated by the questionnaire method. The first questionnaire was asked in all Japanese 1,401 Nuclear Medicine facilities. Answers from 624 institutes (44.5%) were received and analyzed. The radiation-safety management in nuclear medicine institutes was considered to be very well performed everyday. Opinion for the present legal control of nuclear medicine institutes was that the regulation in Japan was too strict for the clinical use of radionuclides. The current regulation is based on the assumption that 1% of all radioactivity used in nuclear medicine institutes contaminates into the draining-water system. The second questionnaire detailing the contamination of radioactivity in the draining-water system was sent to 128 institutes, and 64 answers were received. Of them, 42 institutes were considered to be enough to evaluate the contamination of radioactivity in the draining-water system. There was no difference between 624 institutes answered to the first questionnaire and 42 institutes, where the radioactivity in the draining-water system measured, in the distribution of the institute size, draining-water system equipment and the radioactivity measuring method, and these 42 institutes seemed to be representative of Japanese nuclear medicine institutes. Contamination rate of radioactivity into the draining system was calculated by the value of radioactivity in the collecting tank divided by the amount of radionuclides used daily in each institute. The institutes were divided into two categories on the basis of nuclear medicine practice pattern; type A: in-vivo use only and type B: both in-vivo and in-vitro use. The contamination rate in 27 type A institutes did not exceed 0.01%, whereas in 15 type B institutes the contamination rate distributed widely from undetectable to above 1%. These results indicated that the present regulation for the draining-water system, which assumed

  5. Dissolved organic nitrogen (DON) losses from nested artificially drained lowland catchments with contrasting soil types

    Science.gov (United States)

    Tiemeyer, Bärbel; Kahle, Petra; Lennartz, Bernd

    2010-05-01

    Artificial drainage is a common practice to improve moisture and aeration conditions of agricultural land. It shortens the residence time of water in the soil and may therefore contribute to the degradation of peatlands as well as to the still elevated level of diffuse pollution of surface water bodies, particularly if flow anomalies like preferential flow cause a further acceleration of water and solute fluxes. Especially in the case of nitrate, artificially drained sub-catchments are found to control the catchment-scale nitrate losses. However, it is frequently found that nitrate losses and nitrogen field balances do not match. At the same time, organic fertilizers are commonly applied and, especially in lowland catchments, organic soils have been drained for agricultural use. Thus, the question arises whether dissolved organic nitrogen (DON) forms an important component of the nitrogen losses from artificially drained catchments. However, in contrast to nitrate and even to dissolved organic carbon (DOC), this component is frequently overlooked, especially in nested catchment studies with different soil types and variable land use. Here, we will present data from a hierarchical water quantity and quality measurement programme in the federal state Mecklenburg-Vorpommern (North-Eastern Germany). The monitoring programme in the pleistocene lowland catchment comprises automatic sampling stations at a collector drain outlet (4.2 ha catchment), at a ditch draining arable land on mineral soils (179 ha), at a ditch mainly draining grassland on organic soils (85 ha) and at a brook with a small rural catchment (15.5 km²) of mixed land use and soil types. At all sampling stations, daily to weekly composite samples were taken, while the discharge and the meteorological data were recorded continuously. Water samples were analyzed for nitrate-nitrogen, ammonium-nitrogen and total nitrogen. We will compare two years: 2006/07 was a very wet year (P = 934 mm) with a high summer

  6. Greenhouse gases emission from the sewage draining rivers.

    Science.gov (United States)

    Hu, Beibei; Wang, Dongqi; Zhou, Jun; Meng, Weiqing; Li, Chongwei; Sun, Zongbin; Guo, Xin; Wang, Zhongliang

    2018-01-15

    Carbon dioxide (CO 2 ), methane (CH 4 ) and nitrous oxide (N 2 O) concentration, saturation and fluxes in rivers (Beitang drainage river, Dagu drainage rive, Duliujianhe river, Yongdingxinhe river and Nanyunhe river) of Tianjin city (Haihe watershed) were investigated during July and October in 2014, and January and April in 2015 by static headspace gas chromatography method and the two-layer model of diffusive gas exchange. The influence of environmental variables on greenhouse gases (GHGs) concentration under the disturbance of anthropogenic activities was discussed by Spearman correlative analysis and multiple stepwise regression analysis. The results showed that the concentration and fluxes of CO 2 , CH 4 and N 2 O were seasonally variable with >winter>fall>summer, spring>summer>winter>fall and summer>spring>winter>fall for concentrations and spring>summer>fall>winter, spring>summer>winter>fall and summer>spring>fall>winter for fluxes respectively. The GHGs concentration and saturation were higher in comprehensively polluted river sites and lower in lightly polluted river sites. The three GHGs emission fluxes in two sewage draining rivers of Tianjin were clearly higher than those of other rivers (natural rivers) and the spatial variation of CH 4 was more obvious than the others. CO 2 and N 2 O air-water interface emission fluxes of the sewage draining rivers in four seasons were about 1.20-2.41 times and 1.13-3.12 times of those in the natural rivers. The CH 4 emission fluxes of the sewage draining rivers were 3.09 times in fall to 10.87 times in spring of those in the natural rivers in different season. The wind speed, water temperature and air temperature were related to GHGs concentrations. Nitrate and nitrite (NO 3 - +NO 2 - -N) and ammonia (NH 4 + -N) were positively correlated with CO 2 concentration and CH 4 concentration; and dissolved oxygen (DO) concentration was negatively correlated with CH 4 concentration and N 2 O concentration. The effect of

  7. Hydrobiogeochemical interactions in 'anoxic' limestone drains for neutralization of acidic mine drainage

    Science.gov (United States)

    Robbins, E.I.; Cravotta, C.A.; Savela, C.E.; Nord, G.L.

    1999-01-01

    Processes affecting neutralization of acidic coal mine drainage were evaluated within 'anoxic' limestone drains (ALDs). Influents had pH???3.5 and dissolved oxygen Al3+ and Fe3+ compounds. Cleavage mounts of calcite and gypsum that were suspended within the ALDs and later examined microscopically showed dissolution features despite coatings by numerous bacteria, biofilms, and Fe-Al-Si precipitates. In the drain exhibiting the greatest flow reduction, Al-hydroxysulfates had accumulated on limestone surfaces and calcite etch points, thus causing the decline in transmissivity and dissolution. Therefore, where Al loadings are high and flow rates are low, a pre-treatment step is indicated to promote Al removal before diverting acidic mine water into alkalinity-producing materials. ?? 1998 Elsevier Science Ltd.

  8. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Grigoriev, Sergey; Lyublin, Boris; Maquet, Philippe; Senik, Konstantin; Pak, Sunil; Udintsev, Victor

    2016-01-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  9. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Tanchuk, Victor, E-mail: Victor.Tanchuk@sintez.niiefa.spb.su [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Grigoriev, Sergey; Lyublin, Boris [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Senik, Konstantin [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Pak, Sunil [National Fusion Research Institute, Daejeon (Korea, Republic of); Udintsev, Victor [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France)

    2016-11-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  10. Brain drain: a challenge to global mental health

    OpenAIRE

    Oladeji, Bibilola D.; Gureje, Oye

    2016-01-01

    The brain drain of medical professionals from lower-income to higher-income countries contributes to the current inequity that characterises access to mental healthcare by those in need across the world and hinders efforts to scale up mental health services in resource-constrained settings, especially in Nigeria and other West African countries. The migration of skilled workers is driven by a combination of the globalisation of the labour market and the ability of highly resourced countries t...

  11. A questionnaire about radiation safety management of the draining-water system at nuclear medicine facilities

    International Nuclear Information System (INIS)

    Shizukuishi, Kazuya; Narita, Hiroto

    2004-01-01

    We conducted a questionnaire survey about radiation-safety management condition in Japanese nuclear medicine facilities to make materials of proposition for more reasonable management of medical radioactive waste. We distributed a questionnaire to institutions equipped with Nuclear Medicine facilities. Of 1,125 institutions, 642 institutes (52.8%) returned effective answers. The questionnaire covered the following areas: scale of an institution, presence of enforcement of radiotherapy, system of a tank, size and number of each tank, a form of draining-water system, a displacement in a radioactive rays management area, a measurement method of the concentration of medical radioactive waste in draining water system, planned and used quantity of radioisotopes for medical examination and treatment, an average displacement of hospital for one month. In most institutions, a ratio of dose limitation of radioisotope in draining-water system was less than 1.0, defined as an upper limitation in ordinance. In 499 hospitals without facilities of hospitalization for unsealed radioisotope therapy, 473 hospitals reported that sum of ratios of dose limits in a draining-water system was less than 1.0. It was calculated by used dose of radioisotope and monthly displacement from hospital, on the premise that all used radioisotope entered in the general draining-water system. When a drainage including radioactivity from a controlled area join with that from other area before it flows out of a institution, it may be diluted and its radioactive concentration should be less than its upper limitation defined in the rule. Especially, in all institutions with a monthly displacement of more than 25,000 m 3 , the sum of ratio of the concentration of each radionuclide to the concentration limit dose calculated by used dose of radioisotope, indicated less than 1.0. (author)

  12. PWSCC Potential on the Drain Tubes of WEC Model 51F Steam Generators in Domestic Plants

    International Nuclear Information System (INIS)

    Chang, B. I.; Song, M. S.; Yoon, K. S.; Kim, I. Y.

    2009-01-01

    The drain couplings of Westinghouse Model 51F steam generators that had been operated in the domestic Nuclear Power Plants were modified and repaired in accordance with the corrective action of replacing the existing Alloy 600 weld build-up with Alloy 690(Alloy 52/152) weld build-up in order to increase its resistance to primary water stress corrosion cracking (PWSCC). The drain tube made of alloy 600, however, was not replaced and left susceptible to the PWSCC. Among the environmental, metallurgical and mechanical factors controlling a susceptibility to the PWSCC, it is believed that tensile stresses play an important role. The objective of this study is to conservatively estimate stress state of the drain tube during fabrication and when exposed to normal plant operations, and to investigate its potential for the PWSCC

  13. A low on-resistance SOI LDMOS using a trench gate and a recessed drain

    International Nuclear Information System (INIS)

    Ge Rui; Luo Xiaorong; Jiang Yongheng; Zhou Kun; Wang Pei; Wang Qi; Wang Yuangang; Zhang Bo; Li Zhaoji

    2012-01-01

    An integrable silicon-on-insulator (SOI) power lateral MOSFET with a trench gate and a recessed drain (TGRD MOSFET) is proposed to reduce the on-resistance. Both of the trench gate extended to the buried oxide (BOX) and the recessed drain reduce the specific on-resistance (R on,sp ) by widening the vertical conduction area and shortening the extra current path. The trench gate is extended as a field plate improves the electric field distribution. Breakdown voltage (BV) of 97 V and R on,sp of 0.985 mΩ·cm 2 (V GS = 5 V) are obtained for a TGRD MOSFET with 6.5 μm half-cell pitch. Compared with the trench gate SOI MOSFET (TG MOSFET) and the conventional MOSFET, R on,sp of the TGRD MOSFET decreases by 46% and 83% at the same BV, respectively. Compared with the SOI MOSFET with a trench gate and a trench drain (TGTD MOSFET), BV of the TGRD MOSFET increases by 37% at the same R on,sp . (semiconductor devices)

  14. The "brain drain" of health care workers: causes, solutions and the example of Jamaica.

    Science.gov (United States)

    Lofters, Aisha K

    2012-07-18

    Despite much media attention being given to the physician shortage in Canada in recent years, this shortage pales in comparison to that seen in many middle- and low-income countries. A major cause of the shortage in these countries is the migration of health care workers from developing to developed nations, a phenomenon known as the "brain drain". The loss of these workers is having devastating impacts globally, particularly in Sub-Saharan Africa and the Caribbean. Causes of the "brain drain" are numerous and include poor working conditions in poorer countries and active recruitment by richer countries. Jamaica has been one of the countries in the Caribbean hardest hit by mass migration of health care workers. The multiple dimensions of Jamaica's health worker "brain drain" illustrate both the complexity of the issues reviewed in this commentary, and the net loss for low- and middle-income countries. Creative and sustainable solutions to the problem are actively being sought globally, but will require commitment and support from all nations as well as from international funding bodies if meaningful impacts on health are to be realized.

  15. Brain Drain: A Child's Brain on Poverty. Poverty Fact Sheet

    Science.gov (United States)

    Damron, Neil

    2015-01-01

    "Brain Drain: A Child's Brain on Poverty," released in March 2015 and prepared by intern Neil Damron, explores the brain's basic anatomy and recent research findings suggesting that poverty affects the brain development of infants and young children and the potential lifelong effects of the changes. The sheet draws from a variety of…

  16. N loss to drain flow and N2O emissions from a corn-soybean rotation with winter rye.

    Science.gov (United States)

    Gillette, K; Malone, R W; Kaspar, T C; Ma, L; Parkin, T B; Jaynes, D B; Fang, Q X; Hatfield, J L; Feyereisen, G W; Kersebaum, K C

    2018-03-15

    Anthropogenic perturbation of the global nitrogen cycle and its effects on the environment such as hypoxia in coastal regions and increased N 2 O emissions is of increasing, multi-disciplinary, worldwide concern, and agricultural production is a major contributor. Only limited studies, however, have simultaneously investigated NO 3 - losses to subsurface drain flow and N 2 O emissions under corn-soybean production. We used the Root Zone Water Quality Model (RZWQM) to evaluate NO 3 - losses to drain flow and N 2 O emissions in a corn-soybean system with a winter rye cover crop (CC) in central Iowa over a nine year period. The observed and simulated average drain flow N concentration reductions from CC were 60% and 54% compared to the no cover crop system (NCC). Average annual April through October cumulative observed and simulated N 2 O emissions (2004-2010) were 6.7 and 6.0kgN 2 O-Nha -1 yr -1 for NCC, and 6.2 and 7.2kgNha -1 for CC. In contrast to previous research, monthly N 2 O emissions were generally greatest when N loss to leaching were greatest, mostly because relatively high rainfall occurred during the months fertilizer was applied. N 2 O emission factors of 0.032 and 0.041 were estimated for NCC and CC using the tested model, which are similar to field results in the region. A local sensitivity analysis suggests that lower soil field capacity affects RZWQM simulations, which includes increased drain flow nitrate concentrations, increased N mineralization, and reduced soil water content. The results suggest that 1) RZWQM is a promising tool to estimate N 2 O emissions from subsurface drained corn-soybean rotations and to estimate the relative effects of a winter rye cover crop over a nine year period on nitrate loss to drain flow and 2) soil field capacity is an important parameter to model N mineralization and N loss to drain flow. Published by Elsevier B.V.

  17. Relationship of bleeding complications and impairment of draining veins after α-n-butyl cyanoacrylate embolization of brain arteriovenous malformations

    International Nuclear Information System (INIS)

    Fang Bing; Wang Yirong; Li Tielin; Duan Chuanzhi; Wang Qiujing; Zhao Qingping

    2007-01-01

    Objective: To investigate the causes, consequences and management of injuries to the draining veins after embolization of brain arterioven0us malformations (BAVMs) with α-n-butyl cyanoacrylate (NBCA). Methods: The angiographic imaging data of 189 BAVMs patients who underwent NBCA embolization were studied retrospectively. The status of the draining veins before and after NBCA embolization was observed and compared. The intracerebral hemorrhage (ICH)complications and their relation to their angiographic features were analyzed. Results: Twenty-three patients out of 189 patients showed injuries to the draining venous system, including 10 low-grade injury, 6 moderate injury, and 7 high-grade injury. Six patients suffered from ICH after embolization, of whom 4 patients were due to injuries of the draining veins (2 moderate and 2 high-grade). In the 3 months follow-up evaluation of 4 patients with ICH, one died, one was in vegetative state, and the other two patients suffered from residual severe or minor (1 patient for each) permanent neurological deficits. Conclusion: Our findings suggest that injury of the draining veins is the major cause of ICH and may lead to serious consequences after embolization of BAVMs with NBCA. (authors)

  18. Assessment of the use of selected chemical and microbiological constituents as indicators of wastewater in curtain drains from home sewage-treatment systems in Medina County, Ohio

    Science.gov (United States)

    Dumouchelle, Denise H.

    2006-01-01

    Many home sewage-treatment systems (HSTS) in Ohio use curtain or perimeter drains to depress the level of the subsurface water in and around the systems. These drains could possibly intercept partially untreated wastewater and release potential pathogens to ground-water and surface-water bodies. The quality of water in curtain drains from two different HSTS designs in Medina County, Ohio, was investigated using several methods. Six evaporation-transpiration-absorption (ETA) and five leach-line (LL) systems were investigated by determining nutrient concentrations, chloride/bromide ratios (Cl/Br), Escherichia coli (E. coli ) concentrations, coliphage genotyping, and genetic fingerprinting of E. coli. Water samples were collected at 11 sites and included samples from curtain drains, septic tanks, and residential water wells. Nitrate concentrations in the curtain drains ranged from 0.03 to 3.53 mg/L (milligrams per liter), as N. Concentrations of chloride in 10 of the 11 curtain drains ranged from 5.5 to 21 mg/L; the chloride concentration in the eleventh curtain drain was 340 mg/L. Bromide concentrations in 11 curtain drains ranged from 0.01 to 0.22 mg/L. Cl/Br ratios ranged from 86 to 2,000. F-specific coliphage were not found in any curtain-drain samples. Concentrations of E. coli in the curtain drains ranged from 1 to 760 colonies per 100 milliliters. The curtain-drain water-quality data were evaluated to determine whether HSTS-derived water was present in the curtain drains. Nutrient concentrations were too low to be of use in the determination. The Cl/Br ratios appear promising. Coliphage was not detected in the curtain drains, so genotyping could not be attempted. E. coli concentrations in the curtain drains were all less than those from the corresponding HSTS; only one sample exceeded the Ohio secondary-contact water-quality standard. The genetic fingerprinting data were inconclusive because multiple links between unrelated sites were found. Although the

  19. Globalization and migration: A "unified brain drain" model

    OpenAIRE

    Brezis, Elise S.; Soueri, Ariel

    2012-01-01

    Globalization has led to a vast flow of migration of workers but also of students. The purpose of this paper is to analyze the migration of individuals encompassing decisions already at the level of education. We develop a unified brain drain model that incorporates the decisions of an individual vis - à - vis both education and migration. In the empirical part, this paper addresses international flows of migration within the EU and presents strong evidence of concentration of students in cou...

  20. Modeling the drain current and its equation parameters for lightly doped symmetrical double-gate MOSFETs

    International Nuclear Information System (INIS)

    Bhartia, Mini; Chatterjee, Arun Kumar

    2015-01-01

    A 2D model for the potential distribution in silicon film is derived for a symmetrical double gate MOSFET in weak inversion. This 2D potential distribution model is used to analytically derive an expression for the subthreshold slope and threshold voltage. A drain current model for lightly doped symmetrical DG MOSFETs is then presented by considering weak and strong inversion regions including short channel effects, series source to drain resistance and channel length modulation parameters. These derived models are compared with the simulation results of the SILVACO (Atlas) tool for different channel lengths and silicon film thicknesses. Lastly, the effect of the fixed oxide charge on the drain current model has been studied through simulation. It is observed that the obtained analytical models of symmetrical double gate MOSFETs are in good agreement with the simulated results for a channel length to silicon film thickness ratio greater than or equal to 2. (paper)

  1. Modeling the drain current and its equation parameters for lightly doped symmetrical double-gate MOSFETs

    Science.gov (United States)

    Bhartia, Mini; Chatterjee, Arun Kumar

    2015-04-01

    A 2D model for the potential distribution in silicon film is derived for a symmetrical double gate MOSFET in weak inversion. This 2D potential distribution model is used to analytically derive an expression for the subthreshold slope and threshold voltage. A drain current model for lightly doped symmetrical DG MOSFETs is then presented by considering weak and strong inversion regions including short channel effects, series source to drain resistance and channel length modulation parameters. These derived models are compared with the simulation results of the SILVACO (Atlas) tool for different channel lengths and silicon film thicknesses. Lastly, the effect of the fixed oxide charge on the drain current model has been studied through simulation. It is observed that the obtained analytical models of symmetrical double gate MOSFETs are in good agreement with the simulated results for a channel length to silicon film thickness ratio greater than or equal to 2.

  2. Carbon storage change in a partially forestry-drained boreal mire determined through peat column inventories

    Energy Technology Data Exchange (ETDEWEB)

    Pitkanen, A.; Tahvanainen, T.; Simola, H. [Univ. of Eastern Finland, Joensuu (Finland). Dept. pf Biology; Turunen, J. [Geological Survey of Finland, Kuopio (Finland)

    2013-09-01

    To study the impact of forestry drainage on peat carbon storage, we cored paired quantitative peat samples from undrained and drained sides of an eccentric bog. Five pairs of 0 to {<=} 100-cm-deep surface-peat cores, and a pair of profiles representing the full peat deposit provided stratigraphic evidence of marked loss of surface peat due to drainage. For the drained side cores, we found a relative subsidence of 25-37 cm of the surface, and a loss of about 10 kg{sub DW}{sup m-2}, corresponding to 131 {+-} 28 g C m{sup -2} a{sup -1} (mean {+-} SE) for the post-drainage period. Similar peat loss was also found in the full deposit profiles, thus lending credibility to the whole-column inventory approach, even though the decrease (9 kg{sub DW} m{sup -2}) was relatively small in comparison with the total carbon storage (233 and 224 kg{sub DW} m{sup -2} for the undrained and drained sides, respectively). (orig.)

  3. Land use of drained peatlands: Greenhouse gas fluxes, plant production, and economics.

    Science.gov (United States)

    Kasimir, Åsa; He, Hongxing; Coria, Jessica; Nordén, Anna

    2017-10-10

    Drained peatlands are hotspots for greenhouse gas (GHG) emissions, which could be mitigated by rewetting and land use change. We performed an ecological/economic analysis of rewetting drained fertile peatlands in a hemiboreal climate using different land use strategies over 80 years. Vegetation, soil processes, and total GHG emissions were modeled using the CoupModel for four scenarios: (1) business as usual-Norway spruce with average soil water table of -40 cm; (2) willow with groundwater at -20 cm; (3) reed canary grass with groundwater at -10 cm; and (4) a fully rewetted peatland. The predictions were based on previous model calibrations with several high-resolution datasets consisting of water, heat, carbon, and nitrogen cycling. Spruce growth was calibrated by tree-ring data that extended the time period covered. The GHG balance of four scenarios, including vegetation and soil, were 4.7, 7.1, 9.1, and 6.2 Mg CO 2 eq ha -1  year -1 , respectively. The total soil emissions (including litter and peat respiration CO 2 + N 2 O + CH 4 ) were 33.1, 19.3, 15.3, and 11.0 Mg CO 2 eq ha -1  year -1 , respectively, of which the peat loss contributed 35%, 24%, and 7% of the soil emissions for the three drained scenarios, respectively. No peat was lost for the wet peatland. It was also found that draining increases vegetation growth, but not as drastically as peat respiration does. The cost-benefit analysis (CBA) is sensitive to time frame, discount rate, and carbon price. Our results indicate that the net benefit was greater with a somewhat higher soil water table and when the peatland was vegetated with willow and reed canary grass (Scenarios 2 and 3). We conclude that saving peat and avoiding methane release using fairly wet conditions can significantly reduce GHG emissions, and that this strategy should be considered for land use planning and policy-making. © 2017 John Wiley & Sons Ltd.

  4. Modelling of the draining of a molten glass heated by induction

    International Nuclear Information System (INIS)

    Lima-Da-Silva, Marcio

    2014-01-01

    This thesis is part of the development of a new technology of oxides melting in a furnace heated by induction. The technology studied involves strong interactions between electromagnetic, thermal and hydrodynamic phenomena in a flow with physical properties strongly dependents of the temperature. The aim of the thesis is the modelling of the process by coupling closely the Joule heating, the mechanical stirring and the draining of the furnace. The modeling of the time evolution of the interface between glass and air during the emptying of the cold crucible was performed. Regarding the methodology, we chose to combine two scientific codes: Flux for the electromagnetic calculation and Fluent for thermal-hydraulics. The evolution of the free surface was treated by the multiphasic method 'Volume-Of-Fluid - VOF' and the mechanical stirring by the 'Moving Reference Frame' and the 'Sliding Mesh'. First of all, we considered the draining of a tank filled with a silicon oil of high-viscosity without mechanical stirring. This initial model took into account studies of hydraulic similarity between the silicon oil and the glass. Then we superimposed the forced flow creates by the mechanical stirrer, the thermal and the electromagnetic phenomena in order to model the flow of the molten glass. The final model can provide various parameters, including the time needed to drain the furnace, the heat transfer flux and the time evolution of the mass flow rate and of the temperature inside de furnace. (author) [fr

  5. 7 CFR 58.416 - Cheese vats, tanks and drain tables.

    Science.gov (United States)

    2010-01-01

    ... uniform heating. The inner liner shall be minimum 16 gauge stainless steel or other equally corrosion... jacket. The outer jacket shall be constructed of stainless steel or other metal which can be kept clean... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vats, tanks and drain tables. 58.416 Section 58...

  6. Optimal chest drain size: the rise of the small-bore pleural catheter.

    Science.gov (United States)

    Fysh, Edward T H; Smith, Nicola A; Lee, Y C Gary

    2010-12-01

    Drainage of the pleural space is not a modern concept, but the optimal size of chest drains to use remains debated. Conventional teaching advocates blunt dissection and large-bore tubes; but in recent years, small-bore catheters have gained popularity. In the absence of high-quality randomized data, this review summarizes the available literature on the choice of chest drains. The objective data supporting the use of large-bore tubes is scarce in most pleural diseases. Increasing evidence shows that small-bore catheters induce less pain and are of comparable efficacy to large-bore tubes, including in the management of pleural infection, malignant effusion, and pneumothoraces. The onus now is on those who favor large tubes to produce clinical data to justify the more invasive approach. © Thieme Medical Publishers.

  7. A comparative study of surgical drain placement and the use of kinesiologic tape to reduce postoperative morbidity after third molar surgery.

    Science.gov (United States)

    Genc, Aysenur; Cakarer, Sirmahan; Yalcin, Basak Keskin; Kilic, Beril Berivan; Isler, Sabri Cemil; Keskin, Cengizhan

    2018-04-19

    Our aim was to compare the effects of the surgical drain and kinesiotape applications on postoperative morbidity after mandibular third molar surgery in a split-mouth study design. A single-centre, split-mouth study was performed in 23 patients who needed surgical removal of bilateral mandibular third molars. Each patient was treated with a drain tube on one side of the mandible and Kinesio tape (KT) on the contralateral side. Swelling was significantly greater in the KT group than in the drain group throughout the study period. The groups did not differ significantly in the amount of trismus at any time point. The Visual Analogue Scale (VAS)-measured pain intensity was significantly lower in the drainage group. Patients with KT had greater postoperative discomfort than those with a drain tube. All patients were generally satisfied with their treatments. Although both treatments were useful, a surgical drain was significantly more effective at reducing swelling and pain intensity than Kinesio tape. The effects of both on trismus were similar.

  8. Use of a Nasal Speculum for Chest-Drain Insertion: A Simple Technique

    OpenAIRE

    Saxena, Pankaj; Konstantinov, Igor E.; Newman, Mark A.J.

    2006-01-01

    Tube thoracostomy is a very commonly performed procedure in cardiothoracic surgery. Insertion of a chest drain requires expertise to minimize complications. We describe a simple technique of using a nasal speculum to perform this procedure.

  9. Application of Prefabricated Vertical Drain in Soil Improvement

    Directory of Open Access Journals (Sweden)

    Tedjakusuma B.

    2012-01-01

    Full Text Available Although the use of Prefabricated Vertical Drain (PVD in soil improvement is not new, this paper is interesting since it gives the full spectrum from preliminary design stage; trial embankment and pilot test to final soil improvement. The final installation of the PVD was based on the soil investigation report and the results of instrumentation monitoring. Finally, using back analysis, vertical and horizontal coefficients of consolidation and compression index can be determined, which can be applied to predict a more accurate prediction of settlement.

  10. An elusive persistent left superior vena cava draining into left atrium

    NARCIS (Netherlands)

    A. Soward; F.J. ten Cate (Folkert); P.M. Fioretti (Paolo); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1986-01-01

    textabstractA case report of a persistent left superior vena cava draining into left atrium with a fibromuscular left ventricular outflow tract obstruction and a small atrial septal defect. The anomalous vessel escaped detection during two right and left heart catheterizations from the right arm and

  11. Oral tolerance is determined at the level of draining lymph nodes

    NARCIS (Netherlands)

    Wilsem, van E.G.; BrevÃ, J.; Savelkoul, H.; Claessen, A.; Scheper, R.J.; Kraal, G.

    1995-01-01

    In the skin and in the epithelium of the oral mucosa a comparable network of Langerhans cells can be found. Antigen application on either epithelium leads to rapid emigration of Langerhans cells to the draining lymph nodes. Application on the oral mucosa leads to tolerance induction while

  12. Human capital in European peripheral regions: brain - drain and brain - gain

    NARCIS (Netherlands)

    Coenen, Franciscus H.J.M.

    2004-01-01

    Project goal - The overall goal of the project is to build a legitimate transnational network to transfer ideas and experiences and implement measures to reduce brain drain and foster brain gain while reinforcing the economical and spatial development of peripheral regions in NWE. This means a

  13. Comparative investigation of novel hetero gate dielectric and drain engineered charge plasma TFET for improved DC and RF performance

    Science.gov (United States)

    Yadav, Dharmendra Singh; Verma, Abhishek; Sharma, Dheeraj; Tirkey, Sukeshni; Raad, Bhagwan Ram

    2017-11-01

    Tunnel-field-effect-transistor (TFET) has emerged as one of the most prominent devices to replace conventional MOSFET due to its ability to provide sub-threshold slope below 60 mV/decade (SS ≤ 60 mV/decade) and low leakage current. Despite this, TFETs suffer from ambipolar behavior, lower ON-state current, and poor RF performance. To address these issues, we have introduced drain and gate work function engineering with hetero gate dielectric for the first time in charge plasma based doping-less TFET (DL TFET). In this, the usage of dual work functionality over the drain region significantly reduces the ambipolar behavior of the device by varying the energy barrier at drain/channel interface. Whereas, the presence of dual work function at the gate terminal increases the ON-state current (ION). The combined effect of dual work function at the gate and drain electrode results in the increment of ON-state current (ION) and decrement of ambipolar conduction (Iambi) respectively. Furthermore, the incorporation of hetero gate dielectric along with dual work functionality at the drain and gate electrode provides an overall improvement in the performance of the device in terms of reduction in ambipolarity, threshold voltage and sub-threshold slope along with improved ON-state current and high frequency figures of merit.

  14. Analytical solutions for a single vertical drain with time-dependent vacuum combined surcharge preloading in membrane and membraneless systems

    International Nuclear Information System (INIS)

    Geng, X Y; Indraratna, B; Rujikiatkamjorn, C

    2010-01-01

    Vertical drains combined with vacuum pressure and surcharge preloading are widely used to accelerate the consolidation process of soft clay in order to decrease the pore pressure as well as to increase the effective stress. Currently there are two types of vacuum preloading systems commercially available; (a) membrane system with an airtight membrane over the drainage layer and, (b) membraneless system where a vacuum system is connected to individual drain. Their effectiveness varies from site to site depending on the type of soil treated and the characteristics of the drain-vacuum system. This study presents the analytical solutions of vertical drains with vacuum preloading for both membrane and membraneless systems. According to the field and laboratory observations, the vacuum in both of the membraneless and membrane system was assumed to be decreasing along the drain whereas in the membrane system, it was maintained at a constant level. This model was verified by using the measured settlements and excess pore pressures obtained from large-scale laboratory testing and case studies in Australia. The analytical solutions improved the accuracy of predicting the dissipation of pore water pressure and the associated settlement. The effects of the permeability of the sand blanket in a membrane system and the possible loss of vacuum were also discussed.

  15. Investigation on the electrical characteristics of a pentacene thin-film transistor and its reliability under positive drain bias stress

    International Nuclear Information System (INIS)

    Fan, Ching-Lin; Chiu, Ping-Cheng; Lin, Yu-Zuo; Yang, Tsung-Hsien; Chiang, Chin-Yuan

    2011-01-01

    This study systematically investigates the effects of pentacene deposition rates and channel lengths on the electrical characteristics of pentacene-based organic thin-film transistors (OTFTs), and the performance degradation of OTFTs under the positive drain bias stress. With a slower deposition rate of the pentacene channel layer, the larger grain size is formed, and it improves the performance of pentacene-based OTFTs. As the channel length decreases, the threshold voltage (V TH ) shifts toward the positive direction and the field-effect mobility (µ FE ) decreases, which are due to the drain-induced barrier lowering effect and the lower mobility in the active channel near the region of source/drain electrodes, respectively. In addition, we also propose a mechanism to present the channel length dependence on the field-effect mobility. Results also show that the pentacene-based OTFTs, which are under positive drain bias stress, exhibit greater performance degradation than those under negative drain bias stress. The greater performance degradation, the decreasing I ON and the larger V TH shift are due to the greater trap state density (N trap ) created in the bulk channel by the large lateral electrical field and the carriers injected into the gate insulator by the large vertical electrical field, respectively

  16. Risk assessment of K Basin twelve-inch and four-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-06-23

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rate which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. Five four-inch drain valves are located in the north and south loadout pits (NLOP and SLOP), the weasel pit, the technical viewing pit, and the discharge chute pit. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations indicate that only the valve's bonnet and stem are exposed above the basin concrete floor for the twelve-inch drain valve and that much less of the valve's bonnet and stem are exposed above the basin concrete floor for the five four-inch drain valves. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this analysis are to: (1) evaluate the likelihood of damaging the three twelve-inch drain valves located along the north wall of the main basin and the five four-inch drain valves located in the pits from a seismic initiating event, and (2) determine the likelihood of exceeding a specific consequence (initial leak rate) from a damaged valve. The analysis process is a risk-based uncertainty analysis where each variable is modeled using available information and engineering judgement. The uncertainty associated with each variable is represented by a probability distribution (probability density function). Uncertainty exists because of the inherent

  17. Influence of slow-release urea on nitrogen balance and portal-drained visceral nutrient flux in beef steers

    DEFF Research Database (Denmark)

    Taylor-Edwards, C C; Elam, N A; Kitts, S E

    2009-01-01

    Two experiments were conducted to evaluate the effects of slow-release urea (SRU) versus feed-grade urea on portal-drained visceral (PDV) nutrient flux, nutrient digestibility, and total N balance in beef steers.......Two experiments were conducted to evaluate the effects of slow-release urea (SRU) versus feed-grade urea on portal-drained visceral (PDV) nutrient flux, nutrient digestibility, and total N balance in beef steers....

  18. Global estimates of high-level brain drain and deficit.

    Science.gov (United States)

    Ioannidis, John P A

    2004-06-01

    Brain drain, the international migration of scientists in search of better opportunities, has been a long-standing concern, but quantitative measurements are uncommon and limited to specific countries or disciplines. We need to understand brain drain at a global level and estimate the extent to which scientists born in countries with low opportunities never realize their potential. Data on 1523 of the most highly cited scientists for 1981-1999 are analyzed. Overall, 31.9% of these scientists did not reside in the country where they were born (range 18.1-54.6% across 21 different scientific fields). There was great variability across developed countries in the proportions of foreign-born resident scientists and emigrating scientists. Countries without a critical mass of native scientists lost most scientists to migration. This loss occurred in both developed and developing countries. Adjusting for population and using the U.S. as reference, the number of highly cited native-born scientists was at least 75% of the expected number in only 8 countries other than the U.S. It is estimated that approximately 94% of the expected top scientists worldwide have not been able to materialize themselves due to various adverse conditions. Scientific deficit is only likely to help perpetuate these adverse conditions.

  19. Fine root production at drained peatland sites

    Energy Technology Data Exchange (ETDEWEB)

    Finer, L [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Laine, J [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1997-12-31

    The preliminary results of the Finnish project `Carbon balance of peatlands and climate change` show that fine roots play an important role in carbon cycling on peat soils. After drainage the roots of mire species are gradually replaced by the roots of trees and other forest species. Pine fine root biomass reaches a maximum level by the time of crown closure, some 20 years after drainage on pine mire. The aim of this study is to compare the results of the sequential coring method and the ingrowth bag method used for estimating fine root production on three drained peatland sites of different fertility. The results are preliminary and continuation to the work done in the study Pine root production on drained peatlands, which is part of the Finnish project `Carbon cycling on peatlands and climate change`. In this study the fine root biomass was greater on the poor site than on the rich sites. Pine fine root production increased with the decrease in fertility. Root turnover and the production of field layer species were greater on the rich sites than on the poor site. The results suggested that the in growth bag method measured more root activity than the magnitude of production. More than two growing seasons would have been needed to balance the root dynamics in the in growth bags with the surrounding soil. That time would probably have been longer on the poor site than on the rich ones and longer for pine and field layer consisting of dwarf shrubs than for field layer consisting of sedge like species and birch. (11 refs.)

  20. Fine root production at drained peatland sites

    Energy Technology Data Exchange (ETDEWEB)

    Finer, L. [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Laine, J. [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1996-12-31

    The preliminary results of the Finnish project `Carbon balance of peatlands and climate change` show that fine roots play an important role in carbon cycling on peat soils. After drainage the roots of mire species are gradually replaced by the roots of trees and other forest species. Pine fine root biomass reaches a maximum level by the time of crown closure, some 20 years after drainage on pine mire. The aim of this study is to compare the results of the sequential coring method and the ingrowth bag method used for estimating fine root production on three drained peatland sites of different fertility. The results are preliminary and continuation to the work done in the study Pine root production on drained peatlands, which is part of the Finnish project `Carbon cycling on peatlands and climate change`. In this study the fine root biomass was greater on the poor site than on the rich sites. Pine fine root production increased with the decrease in fertility. Root turnover and the production of field layer species were greater on the rich sites than on the poor site. The results suggested that the in growth bag method measured more root activity than the magnitude of production. More than two growing seasons would have been needed to balance the root dynamics in the in growth bags with the surrounding soil. That time would probably have been longer on the poor site than on the rich ones and longer for pine and field layer consisting of dwarf shrubs than for field layer consisting of sedge like species and birch. (11 refs.)

  1. A comparison of post-op haemoglobin levels and allogeneic blood transfusion rates following total knee arthroplasty without drainage or with reinfusion drains.

    Science.gov (United States)

    Hazarika, Shariff; Bhattacharya, Rajarshi; Bhavikatti, Mainudden; Dawson, Matthew

    2010-02-01

    The effects of re-infusion drains on the rate of allogeneic blood transfusion and post-op haemoglobin levels in Total Knee Arthroplasty were examined. A group of 22 patients undergoing primary Total Knee Arthroplasty using a CBCII Constavac Stryker re-infusion drainage system were compared with a group of 30 patients, matched for age, sex and type of prosthesis but without any drain usage. The re-infusion drain.group had a significantly lower day 1 and day 3 post-operative haemoglobin compared to the non-drainage group. The re-infusion drain group had a higher allogenic transfusion rate compared to the non-drainage group. There were no significant differences between the two groups regarding the rate of wound and transfusion related complications and mean length of post-operative stay. We found that reinfusion drains were ineffective in reducing allogeneic transfusion requirements as compared with non-drainage in total knee arthroplasty.

  2. PEAT-CO2. Assessment of CO2 emissions from drained peatlands in SE Asia

    International Nuclear Information System (INIS)

    Hooijer, A.; Silvius, M.; Woesten, H.; Page, S.

    2006-12-01

    Forested tropical peatlands in SE Asia store at least 42,000 Megatonnes of soil carbon. This carbon is increasingly released to the atmosphere due to drainage and fires associated with plantation development and logging. Peatlands make up 12% of the SE Asian land area but account for 25% of current deforestation. Out of 27 million hectares of peatland, 12 million hectares (45%) are currently deforested and mostly drained. One important crop in drained peatlands is palm oil, which is increasingly used as a biofuel in Europe. In the PEAT-CO2 project, present and future emissions from drained peatlands were quantified using the latest data on peat extent and depth, present and projected land use and water management practice, decomposition rates and fire emissions. It was found that current likely CO2 emissions caused by decomposition of drained peatlands amounts to 632 Mt/y (between 355 and 874 Mt/y). This emission will increase in coming decades unless land management practices and peatland development plans are changed, and will continue well beyond the 21st century. In addition, over 1997-2006 an estimated average of 1400 Mt/y in CO2 emissions was caused by peatland fires that are also associated with drainage and degradation. The current total peatland CO2 emission of 2000 Mt/y equals almost 8% of global emissions from fossil fuel burning. These emissions have been rapidly increasing since 1985 and will further increase unless action is taken. Over 90% of this emission originates from Indonesia, which puts the country in 3rd place (after the USA and China) in the global CO2 emission ranking. It is concluded that deforested and drained peatlands in SE Asia are a globally significant source of CO2 emissions and a major obstacle to meeting the aim of stabilizing greenhouse gas emissions, as expressed by the international community. It is therefore recommended that international action is taken to help SE Asian countries, especially Indonesia, to better conserve

  3. Preservation of labile organic matter in soils of drained thaw lakes in Northern Alaska

    Science.gov (United States)

    Mueller, Carsten W.; Rethemeyer, Janet; Kao-Kniffin, Jenny; Löppmann, Sebastian; Hinkel, Kenneth; Bockheim, James

    2014-05-01

    A large number of studies predict changing organic matter (OM) dynamics in arctic soils due to global warming. In contrast to rather slowly altering bulk soil properties, single soil organic matter (SOM) fractions can provide a more detailed picture of the dynamics of differently preserved SOM pools in climate sensitive arctic regions. By the study of the chemical composition of such distinctive SOM fractions using nuclear magnetic resonance spectroscopy (NMR) together with radiocarbon analyses it is possible to evaluate the stability of the major OM pools. Approximately 50-75% of Alaska's Arctic Coastal Plain is covered with thaw lakes and drained thaw lakes that follow a 5,000 yr cycle of development (between creation and final drainage), thus forming a natural soil chronosequence. The drained thaw lakes offer the possibility to study SOM dynamics affected by permafrost processes over millennial timescales. In April 2010 we sampled 16 soil cores (including the active and permanent layer) reaching from young drained lakes (0-50 years since drainage) to ancient drained lakes (3000-5500 years since drainage). Air dried soil samples from soil horizons of the active and permanent layer were subjected to density fractionation in order to differentiate particulate OM and mineral associated OM. The chemical composition of the SOM fractions was analyzed by 13C CPMAS NMR spectroscopy. For a soil core of a young and an ancient drained thaw lake basin we also analyzed the 14C content. For the studied soils we can show that up to over 25 kg OC per square meter are stored mostly as labile, easily degradable organic matter rich in carbohydrates. In contrast only 10 kg OC per square meter were sequestered as presumably more stable mineral associated OC dominated by aliphatic compounds. Comparable to soils of temperate regions, we found small POM (dating we could show the stabilization of younger more labile OM at greater depth in buried O horizons. Additionally the study of the

  4. Final Report: Baseline Selenium Monitoring of Agricultural Drains Operated by the Imperial Irrigation District in the Salton Sea Basin, California

    Science.gov (United States)

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2010-01-01

    This report summarizes comprehensive findings from a 4-year-long field investigation to document baseline environmental conditions in 29 agricultural drains and ponds operated by the Imperial Irrigation District along the southern border of the Salton Sea. Routine water-quality collections and fish community assessments were conducted on as many as 16 sampling dates at roughly quarterly intervals from July 2005 to April 2009. The water-quality measurements included total suspended solids and total (particulate plus dissolved) selenium. With one exception, fish were surveyed with baited minnow traps at quarterly intervals during the same time period. However, in July 2007, fish surveys were not conducted because we lacked permission from the California Department of Fish and Game for incidental take of desert pupfish (Cyprinodon macularius), an endangered species. During April and October 2006-08, water samples also were collected from seven intensively monitored drains (which were selected from the 29 total drains) for measurement of particulate and dissolved selenium, including inorganic and organic fractions. In addition, sediment, aquatic food chain matrices [particulate organic detritus, filamentous algae, net plankton, and midge (chironomid) larvae], and two fish species (western mosquitofish, Gambusia affinis; and sailfin molly, Poecilia latipinna) were sampled from the seven drains for measurement of total selenium concentrations. The mosquitofish and mollies were intended to serve as surrogates for pupfish, which we were not permitted to sacrifice for selenium determinations. Water quality (temperature, dissolved oxygen, pH, specific conductance, and turbidity) values were typical of surface waters in a hot, arid climate. A few drains exhibited brackish, near-anoxic conditions, especially during summer and fall when water temperatures occasionally exceeded 30 degrees Celsius. Total selenium concentrations in water were directly correlated with salinity and

  5. Study on the drain bias effect on negative bias temperature instability degradation of an ultra-short p-channel metal-oxide-semiconductor field-effect transistor

    International Nuclear Information System (INIS)

    Yan-Rong, Cao; Xiao-Hua, Ma; Yue, Hao; Shi-Gang, Hu

    2010-01-01

    This paper studies the effect of drain bias on ultra-short p-channel metal-oxide-semiconductor field-effect transistor (PMOSFET) degradation during negative bias temperature (NBT) stress. When a relatively large gate voltage is applied, the degradation magnitude is much more than the drain voltage which is the same as the gate voltage supplied, and the time exponent gets larger than that of the NBT instability (NBTI). With decreasing drain voltage, the degradation magnitude and the time exponent all get smaller. At some values of the drain voltage, the degradation magnitude is even smaller than that of NBTI, and when the drain voltage gets small enough, the exhibition of degradation becomes very similar to the NBTI degradation. When a relatively large drain voltage is applied, with decreasing gate voltage, the degradation magnitude gets smaller. However, the time exponent becomes larger. With the help of electric field simulation, this paper concludes that the degradation magnitude is determined by the vertical electric field of the oxide, the amount of hot holes generated by the strong channel lateral electric field at the gate/drain overlap region, and the time exponent is mainly controlled by localized damage caused by the lateral electric field of the oxide in the gate/drain overlap region where hot carriers are produced. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  6. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    Science.gov (United States)

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  7. Numerical simulation of the transient thermal-hydraulic behaviour of the ITER blanket cooling system under the draining operational procedure

    Energy Technology Data Exchange (ETDEWEB)

    Di Maio, P.A. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy); Dell’Orco, G.; Furmanek, A. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Garitta, S. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy); Merola, M.; Mitteau, R.; Raffray, R. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Spagnuolo, G.A. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy); Vallone, E., E-mail: eug.vallone@gmail.com [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy)

    2015-10-15

    Highlights: • ITER blanket cooling system hydraulic behaviour is studied under draining transient. • A computational approach based on the finite volume method has been followed. • Draining efficiency has been assessed in term of transient duration and residual water. • Transient duration ranges from ∼40 to 50 s, under the reference draining scenario. • Residual water is predicted to range from few tens of gram up to few kilograms. - Abstract: Within the framework of the research and development activities supported by the ITER Organization on the blanket system issues, an intense analysis campaign has been performed at the University of Palermo with the aim to investigate the thermal-hydraulic behaviour of the cooling system of a standard 20° sector of ITER blanket during the draining transient operational procedure. The analysis has been carried out following a theoretical-computational approach based on the finite volume method and adopting the RELAP5 system code. In a first phase, attention has been focused on the development and validation of the finite volume models of the cooling circuits of the most demanding modules belonging to the standard blanket sector. In later phase, attention has been put to the numerical simulation of the thermal-hydraulic transient behaviour of each cooling circuit during the draining operational procedure. The draining procedure efficiency has been assessed in terms of both transient duration and residual amount of coolant inside the circuit, observing that the former ranges typically between 40 and 120 s and the latter reaches at most ∼8 kg, in the case of the cooling circuit of twinned modules #6–7. Potential variations to operational parameters and/or to circuit lay-out have been proposed and investigated to optimize the circuit draining performances. In this paper, the set-up of the finite volume models is briefly described and the key results are summarized and critically discussed.

  8. Flow and transport processes in a macroporous subsurface-drained glacial till soil

    DEFF Research Database (Denmark)

    Villholth, Karen G.; Jensen, Karsten Høgh

    1998-01-01

    disturbance and compaction of the soil surface. Hypothetically introducing fully surface-connected macropores into the calibrated model resulted in a 22% increase in the loss of solute to the drain, indicating the significance of the hydraulic conditions at the soil surface and the model specification thereof......The experimental results from a field-scale tracer experiment in a subsurface-drained glacial till soil were analyzed by the application of a single/dual porosity model (MACRO), optionally accounting for concurrent and interacting flow and transport in the bulk soil porosity as well...... concentration. The exchange was overpredicted and too rapid when the soil aggregate size (distance between macropores) obtained from an image analysis of soil cores was used in the model. On this basis, the model assumption of instant equilibration of the solute across the matrix porosity, disregarding small...

  9. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    OpenAIRE

    Xiao Guo; Kang-He Xie; Yue-Bao Deng

    2014-01-01

    This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1) the flow with the threshold gradie...

  10. Disinfection of drain water of tomato by means of UV radiation and slow sand filtration in real greenhouse circumstances.

    Science.gov (United States)

    De Rocker, E; Goen, K; Van Poucke, K

    2006-01-01

    The efficiency of the disinfection of drain water was tested at 11 greenhouses with tomato cultivation on rockwool substrate in Flanders (Belgium) by means of mycological analysis. In addition the presence of phytopathogenic fungi in the drain water was analysed at 2 supplementary greenhouses with recirculation without disinfection.

  11. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study.

    Science.gov (United States)

    Kumar, Barun; Bhate, Kalyani; Dolas, R S; Kumar, Sn Santhosh; Waknis, Pushkar

    2016-12-01

    Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus.

  12. Land Use Impacts on Water Quality of Rivers draining from Mulanje ...

    African Journals Online (AJOL)

    Land Use Impacts on Water Quality of Rivers draining from Mulanje Mountain: A Case of Ruo River in the Southern Malawi. ... The research recommends an integrated water resources management approach where all users and relevant stakeholders should take an active role in the conservation of Ruo River catchment in ...

  13. Structure of a steady drain-hole vortex in a viscous fluid

    DEFF Research Database (Denmark)

    Bøhling, Lasse; Andersen, Anders Peter; Fabre, D.

    2010-01-01

    We use direct numerical simulations to study a steady bathtub vortex in a cylindrical tank with a central drain-hole, a fiat stress-free surface and velocity prescribed at the inlet. We find that the qualitative structure of the meridional flow does not depend on the radial Reynolds number, where...

  14. Study of drain-extended NMOS under electrostatic discharge stress in 28 nm and 40 nm CMOS process

    Science.gov (United States)

    Wang, Weihuai; Jin, Hao; Dong, Shurong; Zhong, Lei; Han, Yan

    2016-02-01

    Researches on the electrostatic discharge (ESD) performance of drain-extended NMOS (DeNMOS) under the state-of-the-art 28 nm and 40 nm bulk CMOS process are performed in this paper. Three distinguishing phases of avalanche breakdown stage, depletion region push-out stage and parasitic NPN turn on stage of the gate-grounded DeNMOS (GG-DeNMOS) fabricated under 28 nm CMOS process measured with transmission line pulsing (TLP) test are analyzed through TCAD simulations and tape-out silicon verification detailedly. Damage mechanisms and failure spots of GG-DeNMOS under both CMOS processes are thermal breakdown of drain junction. Improvements based on the basic structure adjustments can increase the GG-DeNMOS robustness from original 2.87 mA/μm to the highest 5.41 mA/μm. Under 40 nm process, parameter adjustments based on the basic structure have no significant benefits on the robustness improvements. By inserting P+ segments in the N+ implantation of drain or an entire P+ strip between the N+ implantation of drain and polysilicon gate to form the typical DeMOS-SCR (silicon-controlled rectifier) structure, the ESD robustness can be enhanced from 1.83 mA/μm to 8.79 mA/μm and 29.78 mA/μm, respectively.

  15. Influence of a drain field plate on the forward blocking characteristics of an AlGaN/GaN high electron mobility transistor

    International Nuclear Information System (INIS)

    Zhao Sheng-Lei; Yue Tong; Wang Yi; Luo Jun; Mao Wei; Ma Xiao-Hua; Hao Yue; Chen Wei-Wei

    2013-01-01

    In this paper, the influence of a drain field plate (FP) on the forward blocking characteristics of an AlGaN/GaN high electron mobility transistor (HEMT) is investigated. The HEMT with only a gate FP is optimized, and breakdown voltage V BR is saturated at 1085 V for gate—drain spacing L GD ≥ 8 μm. On the basis of the HEMT with a gate FP, a drain FP is added with L GD = 10 μm. For the length of the drain FP L DF ≤ 2 μm, V BR is almost kept at 1085 V, showing no degradation. When L DF exceeds 2 μm, V BR decreases obviously as L DF increases. Moreover, the larger the L DF , the larger the decrease of V BR . It is concluded that the distance between the gate edge and the drain FP edge should be larger than a certain value to prevent the drain FP from affecting the forward blocking voltage and the value should be equal to the L GD at which V BR begins to saturate in the first structure. The electric field and potential distribution are simulated and analyzed to account for the decrease of V BR

  16. Quality Education Improvement: Yemen and the Problem of the "Brain Drain"

    Science.gov (United States)

    Muthanna, Abdulghani

    2015-01-01

    This paper presents an overview of the problems that hinder improvement of the quality of education in Yemen, with a particular focus on higher education institutions. It discusses in particular the problem of the brain drain and why this phenomenon is occurring in Yemen. Semi-structured interviews with three professors at higher education…

  17. Movement of gasified oil in an infinite stratum drained by a single well

    Energy Technology Data Exchange (ETDEWEB)

    Tomel' gas, V A

    1965-01-01

    This article presents a method of calculating the flow of gas and oil into a well, which drains a reservoir by the solution drive mechanism. The following conditions are assumed: (1) Initially, an infinite homogeneous reservoir is saturated with oil above the bubble point; (2) the well draining the reservoir is operated at constant pressure, below the bubble point; and (3) the reservoir contains 2 zones; the zone fartherest from the well contains only oil at a pressure above the bubble point, while the zone nearest the well contains both oil and gas. The pressure and oil saturation gradients around the well are calculated for a variety of conditions, and the results are shown graphically. As pressure drawdown increases, oil production increases and the gas factor at first decreases and then increases rapidly.

  18. X-ray K-edge analysis of drain lines in Wilhelm Hall, Ames Laboratory

    International Nuclear Information System (INIS)

    Jensen, T.; Whitmore, C.; Iowa State Univ., Ames, IA

    1999-01-01

    From August 12--27, 1998 X-ray K-edge measurements were made on drain lines in seven rooms in Wilhelm Hall, Ames Laboratory. The purpose of these measurements was to determine the extent of thorium (and other heavy metal) contamination inside these pipes. The K-edge method is a noninvasive inspection technique that can provide accurate quantification of heavy metal contamination interior to an object. Of the seven drain lines inspected, one was found to have no significant contamination, three showed significant thorium deposits, two showed mercury contamination, and one line was found to contain mercury, thorium and uranium. The K-edge measurements were found to be consistent with readings from hand-held survey meters, and provided much greater detail on the location and amount of heavy metal contamination

  19. Year 3 Summary Report: Baseline Selenium Monitoring of Agricultural Drains Operated by the Imperial Irrigation District in the Salton Sea Basin

    Science.gov (United States)

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2008-01-01

    This report summarizes findings from the third year of a 4-year-long field investigation to document selected baseline environmental conditions in 29 agricultural drains and ponds operated by the Imperial Irrigation District along the southern border of the Salton Sea. Routine water quality and fish species were measured at roughly quarterly intervals from April 2007 to January 2008. The water quality measurements included total suspended solids and total (particulate plus dissolved) selenium. In addition, during April and October 2007, water samples were collected from seven intensively monitored drains for measurement of particulate and dissolved selenium, including inorganic and organic fractions. In addition, sediment, aquatic food chain matrices (particulate organic detritus, filamentous algae, net plankton, and midge [chironomid] larvae), and two fish species (western mosquitofish, Gambusia affinis; and sailfin molly, Poecilia latipinna) were sampled from the seven drains for measurement of total selenium concentrations. The mosquitofish and mollies were intended to serve as surrogates for desert pupfish (Cyprinodon macularius), an endangered species that we were not permitted to take for selenium determinations. Water quality values were typical of surface waters in a hot desert climate. A few drains exhibited brackish, near anoxic conditions especially during the summer and fall when water temperatures occasionally exceeded 30 degrees C. In general, total selenium concentrations in water varied directly with conductivity and inversely with pH. Although desert pupfish were found in several drains, sometimes in relatively high numbers, the fish faunas of most drains and ponds were dominated by nonnative species, especially red shiner (Cyprinella lutrensis), mosquitofish, and mollies. Dissolved selenium in water samples from the seven intensively monitored drains ranged from 0.700 to 24.1 ug/L, with selenate as the major constituent in all samples. Selenium

  20. SLD-MOSCNT: A new MOSCNT with step-linear doping profile in the source and drain regions

    Science.gov (United States)

    Tahne, Behrooz Abdi; Naderi, Ali

    2017-01-01

    In this paper, a new structure, step-linear doping MOSCNT (SLD-MOSCNT), is proposed to improve the performance of basic MOSCNTs. The basic structure suffers from band to band tunneling (BTBT). We show that using SLD profile for source and drain regions increases the horizontal distance between valence and conduction bands at gate to source/drain junction which reduces BTBT probability. SLD performance is compared with other similar structures which have recently been proposed to reduce BTBT such as MOSCNT with lightly-doped drain and source (LDDS), and with double-light doping in source and drain regions (DLD). The obtained results using a nonequilibrium Green’s function (NEGF) method show that the SLD-MOSCNT has the lowest leakage current, power consumption and delay time, and the highest current ratio and voltage gain. The ambipolar conduction in the proposed structure is very low and can be neglected. In addition, these structures can improve short-channel effects. Also, the investigation of cutoff frequency of the different structures shows that the SLD has the highest cutoff frequency. Device performance has been investigated for gate length from 8 to 20 nm which demonstrates all discussions regarding the superiority of the proposed structure are also valid for different channel lengths. This improvement is more significant especially for channel length less than 12 nm. Therefore, the SLD can be considered as a candidate to be used in the applications with high speed and low power consumption.

  1. Development and testing of watershed-scale models for poorly drained soils

    Science.gov (United States)

    Glenn P. Fernandez; George M. Chescheir; R. Wayne Skaggs; Devendra M. Amatya

    2005-01-01

    Watershed-scale hydrology and water quality models were used to evaluate the crrmulative impacts of land use and management practices on dowrzstream hydrology and nitrogen loading of poorly drained watersheds. Field-scale hydrology and nutrient dyyrutmics are predicted by DRAINMOD in both models. In the first model (DRAINMOD-DUFLOW), field-scale predictions are coupled...

  2. Hydrobiogeochemical interactions in 'anoxic' limestone drains for neutralization of acidic mine drainage

    Science.gov (United States)

    Robbins, E.I.; Cravotta, C.A.; Savela, C.E.; Nord, G.L.

    1999-01-01

    Processes affecting neutralization of acidic coal mine drainage were evaluated within 'anoxic' limestone drains (ALDs). Influents had pH???3.5 and dissolved oxygen treatment step is indicated to promote Al removal before diverting acidic mine water into alkalinity-producing materials. ?? 1998 Elsevier Science Ltd.

  3. Managing Artificially Drained Low-Gradient Agricultural Headwaters for Enhanced Ecosystem Functions

    Science.gov (United States)

    Pierce, Samuel C.; Kröger, Robert; Pezeshki, Reza

    2012-01-01

    Large tracts of lowlands have been drained to expand extensive agriculture into areas that were historically categorized as wasteland. This expansion in agriculture necessarily coincided with changes in ecosystem structure, biodiversity, and nutrient cycling. These changes have impacted not only the landscapes in which they occurred, but also larger water bodies receiving runoff from drained land. New approaches must append current efforts toward land conservation and restoration, as the continuing impacts to receiving waters is an issue of major environmental concern. One of these approaches is agricultural drainage management. This article reviews how this approach differs from traditional conservation efforts, the specific practices of drainage management and the current state of knowledge on the ecology of drainage ditches. A bottom-up approach is utilized, examining the effects of stochastic hydrology and anthropogenic disturbance on primary production and diversity of primary producers, with special regard given to how management can affect establishment of macrophytes and how macrophytes in agricultural landscapes alter their environment in ways that can serve to mitigate non-point source pollution and promote biodiversity in receiving waters. PMID:24832519

  4. Managing Artificially Drained Low-Gradient Agricultural Headwaters for Enhanced Ecosystem Functions

    Directory of Open Access Journals (Sweden)

    Reza Pezeshki

    2012-12-01

    Full Text Available Large tracts of lowlands have been drained to expand extensive agriculture into areas that were historically categorized as wasteland. This expansion in agriculture necessarily coincided with changes in ecosystem structure, biodiversity, and nutrient cycling. These changes have impacted not only the landscapes in which they occurred, but also larger water bodies receiving runoff from drained land. New approaches must append current efforts toward land conservation and restoration, as the continuing impacts to receiving waters is an issue of major environmental concern. One of these approaches is agricultural drainage management. This article reviews how this approach differs from traditional conservation efforts, the specific practices of drainage management and the current state of knowledge on the ecology of drainage ditches. A bottom-up approach is utilized, examining the effects of stochastic hydrology and anthropogenic disturbance on primary production and diversity of primary producers, with special regard given to how management can affect establishment of macrophytes and how macrophytes in agricultural landscapes alter their environment in ways that can serve to mitigate non-point source pollution and promote biodiversity in receiving waters.

  5. Mercury Pollution Studies of Some Rivers Draining the Bibiani-Anwiaso-Bekwai Mining Community of South Western Ghana

    OpenAIRE

    V.K. Nartey; L.K. Doamekpor; S. Sarpong-Kumankuma; T. Akabzaa; F.K. Nyame; J.K. Kutor; D. Adotey

    2011-01-01

    The project assessed the extent of mercury pollution of some rivers that drain the Bibiani-Anwiaso- Bekwai district which is a typical mining community in the south western part of Ghana. In the study, surfacewater and sediment samples were collected from seven streams that drain this mining community and analyzed for total mercury, organic mercury and elemental mercury. Mercury concentrations of non-filtered water was determined using the ICP-OES after reduction with stannous chloride (SnCl2...

  6. Nitrate concentration-drainage flow (C-Q) relationship for a drained agricultural field in Eastern North Carolina Plain

    Science.gov (United States)

    Liu, W.; Youssef, M.; Birgand, F.; Chescheir, G. M.; Maxwell, B.; Tian, S.

    2017-12-01

    Agricultural drainage is a practice used to artificially enhance drainage characteristics of naturally poorly drained soils via subsurface drain tubing or open-ditch systems. Approximately 25% of the U.S. agricultural land requires improved drainage for economic crop production. However, drainage increases the transport of dissolved agricultural chemicals, particularly nitrates to downstream surface waters. Nutrient export from artificially drained agricultural landscapes has been identified as the leading source of elevated nutrient levels in major surface water bodies in the U.S. Controlled drainage has long been practiced to reduce nitrogen export from agricultural fields to downstream receiving waters. It has been hypothesized that controlled drainage reduces nitrogen losses by promoting denitrification, reducing drainage outflow from the field, and increasing plant uptake. The documented performance of the practice was widely variable as it depends on several site-specific factors. The goal of this research was to utilize high frequency measurements to investigate the effect of agricultural drainage and related management practices on nitrate fate and transport for an artificially drained agricultural field in eastern North Carolina. We deployed a field spectrophotometer to measure nitrate concentration every 45 minutes and measured drainage flow rate using a V-notch weir every 15 minutes. Furthermore, we measured groundwater level, precipitation, irrigation amount, temperature to characterize antecedent conditions for each event. Nitrate concentration-drainage flow (C-Q) relationships generated from the high frequency measurements illustrated anti-clockwise hysteresis loops and nitrate flushing mechanism in response to most precipitation and irrigation events. Statistical evaluation will be carried out for the C-Q relationships. The results of our analysis, combined with numerical modeling, will provide a better understanding of hydrological and

  7. Managing health worker migration: a qualitative study of the Philippine response to nurse brain drain

    Directory of Open Access Journals (Sweden)

    Dimaya Roland M

    2012-12-01

    Full Text Available Abstract Background The emigration of skilled nurses from the Philippines is an ongoing phenomenon that has impacted the quality and quantity of the nursing workforce, while strengthening the domestic economy through remittances. This study examines how the development of brain drain-responsive policies is driven by the effects of nurse migration and how such efforts aim to achieve mind-shifts among nurses, governing and regulatory bodies, and public and private institutions in the Philippines and worldwide. Methods Interviews and focus group discussions were conducted to elicit exploratory perspectives on the policy response to nurse brain drain. Interviews with key informants from the nursing, labour and immigration sectors explored key themes behind the development of policies and programmes that respond to nurse migration. Focus group discussions were held with practising nurses to understand policy recipients’ perspectives on nurse migration and policy. Results Using the qualitative data, a thematic framework was created to conceptualize participants’ perceptions of how nurse migration has driven the policy development process. The framework demonstrates that policymakers have recognised the complexity of the brain drain phenomenon and are crafting dynamic policies and programmes that work to shift domestic and global mindsets on nurse training, employment and recruitment. Conclusions Development of responsive policy to Filipino nurse brain drain offers a glimpse into a domestic response to an increasingly prominent global issue. As a major source of professionals migrating abroad for employment, the Philippines has formalised efforts to manage nurse migration. Accordingly, the Philippine paradigm, summarised by the thematic framework presented in this paper, may act as an example for other countries that are experiencing similar shifts in healthcare worker employment due to migration.

  8. The Brain Drain in Mexico--A Subject for Research...or Agenda?

    Science.gov (United States)

    Aupetit, Sylvie Didou

    2006-01-01

    The purpose of this article is to analyse the present state of the discussion and data regarding the brain drain in Mexico. From current data, recent trends show certain peculiarities in the national picture, pointing to an increase in the number of free movers, and a decrease in the number of young people who obtain Mexican government…

  9. Small drains, big problems: the impact of dry weather runoff on shoreline water quality at enclosed beaches.

    Science.gov (United States)

    Rippy, Megan A; Stein, Robert; Sanders, Brett F; Davis, Kristen; McLaughlin, Karen; Skinner, John F; Kappeler, John; Grant, Stanley B

    2014-12-16

    Enclosed beaches along urban coastlines are frequent hot spots of fecal indicator bacteria (FIB) pollution. In this paper we present field measurements and modeling studies aimed at evaluating the impact of small storm drains on FIB pollution at enclosed beaches in Newport Bay, the second largest tidal embayment in Southern California. Our results suggest that small drains have a disproportionate impact on enclosed beach water quality for five reasons: (1) dry weather surface flows (primarily from overirrigation of lawns and ornamental plants) harbor FIB at concentrations exceeding recreational water quality criteria; (2) small drains can trap dry weather runoff during high tide, and then release it in a bolus during the falling tide when drainpipe outlets are exposed; (3) nearshore turbulence is low (turbulent diffusivities approximately 10(-3) m(2) s(-1)), limiting dilution of FIB and other runoff-associated pollutants once they enter the bay; (4) once in the bay, runoff can form buoyant plumes that further limit vertical mixing and dilution; and (5) local winds can force buoyant runoff plumes back against the shoreline, where water depth is minimal and human contact likely. Outdoor water conservation and urban retrofits that minimize the volume of dry and wet weather runoff entering the local storm drain system may be the best option for improving beach water quality in Newport Bay and other urban-impacted enclosed beaches.

  10. Managing erosion, sediment transport and water quality in drained peatland catchments

    Energy Technology Data Exchange (ETDEWEB)

    Marttila, H.

    2010-07-01

    Peatland drainage changes catchment conditions and increases the transport of suspended solids (SS) and nutrients. New knowledge and management methods are needed to reduce SS loading from these areas. This thesis examines sediment delivery and erosion processes in a number of peatland drainage areas and catchments in order to determine the effects of drainage on sediment and erosion dynamics and mechanics. Results from studies performed in peat mining, peatland forestry and disturbed headwater catchments in Finland are presented and potential sediment load management methods are discussed for drainage areas and headwater brooks. Particular attention is devoted to erosion of organic peat, sediment transport and methods to reduce the impacts of peatland drainage in boreal headwaters. This thesis consists of six articles. The first and second papers focus on the erosion and sediment transport processes at peat harvesting and peatland forestry drainage networks. The results indicate that in-channel processes are important in drained peatland, since the drainage network often constitutes temporary inter-storm storage for eroding and transporting material. Sediment properties determine the bed sediment erosion sensitivity, as fluffy organic peat sediment consolidates over time. As flashiness and peak runoff control sediment entrainment and transport from drained peatland areas, water quality management should include peak runoff management. The third, fourth and fifth papers studies use and application of peak runoff control (PRC) method to the peat harvesting and peatland forestry conditions for water protection. Results indicate that effective water quality management in drained peatland areas can be achieved using this method. Installation of the PRC structures is a useful and cost-effective way of storing storm runoff waters temporarily in the ditch system and providing a retention time for eroded sediment to settle to the ditch bed and drainage network. The main

  11. Effect of drains on the seepage of contaminants from subgrade tailings disposal areas

    International Nuclear Information System (INIS)

    Witten, A.J.; Pin, F.G.; Sharp, R.D.

    1984-01-01

    A numerical simulation study is performed to investigate the influence of ponded water and a bottom drain on the pathways for contaminant migration from a subgrade uranium mill tailings disposal pit. A numerical model is applied to a generic disposal pit constructed with a bottom clay liner and steep unlined sidewalls. The migration of a two-contaminant system is modeled assuming that neither contaminant decays and only one contaminant is retarded. Two dominant pathways are identified; one associated with lateral sidewall leakage and the other associated with transport through the bottom clay liner. It is found that the drain serves to reduce migration through the sidewall which, in turn, prevents the retarded contaminant from reaching the aquifer. The ponded water provides increased head which causes an accelerated vertical movement of moisture through the clay liner. 2 references, 8 figures

  12. A new design equation for drained stability of conical slopes in cohesive-frictional soils

    Directory of Open Access Journals (Sweden)

    Boonchai Ukritchon

    2018-04-01

    Full Text Available New plasticity solutions to the drained stability of conical slopes in homogeneous cohesive-frictional soils were investigated by axisymmetric finite element limit analysis. Three parameters were studied, i.e. excavated height ratios, slope inclination angles, and soil friction angles. The influences of these parameters on the stability factor and predicted failure mechanism of conical slopes were discussed. A new design equation developed from a nonlinear regression of the lower bound solution was proposed for drained stability analyses of a conical slope in practice. Numerical examples were given to demonstrate a practical application of the proposed equation to stability evaluations of conical slopes with both associated and non-associated flow rules. Keywords: Limit analysis, Slope stability, Conical slope, Unsupported excavation, Cohesive-frictional soils

  13. Ensemble Monte Carlo particle investigation of hot electron induced source-drain burnout characteristics of GaAs field-effect transistors

    Science.gov (United States)

    Moglestue, C.; Buot, F. A.; Anderson, W. T.

    1995-08-01

    The lattice heating rate has been calculated for GaAs field-effect transistors of different source-drain channel design by means of the ensemble Monte Carlo particle model. Transport of carriers in the substrate and the presence of free surface charges are also included in our simulation. The actual heat generation was obtained by accounting for the energy exchanged with the lattice of the semiconductor during phonon scattering. It was found that the maximum heating rate takes place below the surface near the drain end of the gate. The results correlate well with a previous hydrodynamic energy transport estimate of the electronic energy density, but shifted slightly more towards the drain. These results further emphasize the adverse effects of hot electrons on the Ohmic contacts.

  14. Characterization Plan for Soils Around Drain Line PLA-100115

    Energy Technology Data Exchange (ETDEWEB)

    D. Shanklin

    2006-05-24

    This Characterization Plan supports the Hazardous Waste Management Act/Resource Conservation and Recovery Act (HWMA/RCRA) closure of soils that may have been contaminated by releases from drain line PLA-100115, located within the Idaho Nuclear Technology and Engineering Center at the Idaho National Laboratory Site. The requirements to address the closure of soils contaminated by a potential release from this line in a characterization plan was identified in the "HWMA/RCRA Less Than 90-day Generator Closure Report for the VES-SFE-126."

  15. Source-Drain Punch-Through Analysis of High Voltage Off-State AlGaN/GaN HEMT Breakdown

    Science.gov (United States)

    Jiang, H.; Li, X.; Wang, J.; Zhu, L.; Wang, H.; Liu, J.; Wang, M.; Yu, M.; Wu, W.; Zhou, Y.; Dai, G.

    2017-06-01

    AlGaN/GaN high-electron mobility transistor’s (HEMT’s) off-state breakdown is investigated using conventional three-terminal off-state breakdown I-V measurement. Competition between gate leakage and source-injection buffer leakage (SIBL) is discussed in detail. It is found that the breakdown is dominated by source-injection which is sensitive to gate voltage and gate length at large gate-to-drain spacing (Lgd > 7μm), where a threshold drain voltage of the occurrence of the SIBL current in GaN buffer exists, and after this threshold voltage the SIBL current continually increased till the buffer breakdown. Our analysis showed that due to the punch-through effect in the buffer, a potential barrier between 2DEG and GaN buffer at the source side mainly controlled by the drain voltage determines the buffer leakage current and the occurrence of the following buffer breakdown, which could explain the experimentally observed breakdown phenomenon.

  16. Performance optimization of MOS-like carbon nanotube-FETs with realistic source/drain contacts based on electrostatic doping

    International Nuclear Information System (INIS)

    Zhou Hailiang; Zhang Minxuan; Hao Yue

    2010-01-01

    Due to carrier band-to-band-tunneling (BTBT) through channel-source/drain contacts, conventional MOS-like Carbon Nanotube Field Effect Transistors (C-CNFETs) suffer from ambipolar conductance, which deteriorates the device performance greatly. In order to reduce such ambipolar behavior, a novel device structure based on electrostatic doping is proposed and all kinds of source/drain contacting conditions are considered in this paper. The non-equilibrium Green's function (NEGF) formalism based simulation results show that, with proper choice of tuning voltage, such electrostatic doping strategy can not only reduce the ambipolar conductance but also improve the sub-threshold performance, even with source/drain contacts being of Schottky type. And these are both quite desirable in circuit design to reduce the system power and improve the frequency as well. Further study reveals that the performance of the proposed design depends strongly on the choice of tuning voltage value, which should be paid much attention to obtain a proper trade-off between power and speed in application. (semiconductor devices)

  17. Immigrant health workers in Chile: is there a Latin American "brain drain"?

    Directory of Open Access Journals (Sweden)

    Baltica Cabieses

    2012-08-01

    Full Text Available Most research on the phenomenon of "brain drain" (one-way flow of highly skilled/educated individuals has focused on movement between the least developed and most highly developed countries. Therefore, the significance of patterns of migration to middle-income countries such as those in Latin America is less clear. The aim of this study was to outline key features of international health worker "brain drain" to Chile to promote discussion and further research on this phenomenon as it pertains to the Latin American region. The study compared immigrant health workers living in Chile to both Chilean-born health workers and other immigrants living in Chile using a qualitative nationwide dataset (the results of Chile's 2009 National Socioeconomic Characterization Survey. Demographic, socioeconomic, and health-related variables were included in the analyses, which were weighted by population to obtain nationally representative estimates. In 2009, immigrant health workers represented 2.2% of all health personnel and 2.6% of all resident immigrants in the country. While most immigrant health workers had a universitylevel education, about 25% had only a high school-level education or less. There was no statistically significant difference between the distribution of immigrant health workers' household income and that of Chilean-born health workers. A significantly higher proportion of the immigrant group reported no entitlement to health care provision. While the results of this study do not indicate a significant international health worker "brain drain" to Chile, they do suggest distinctive patterns of migration within the Latin American region. Future studies in Chile could confirm the validity of these results, using a larger sample of immigrant health workers.

  18. Immigrant health workers in Chile: is there a Latin American "brain drain"?

    Science.gov (United States)

    Cabieses, Baltica; Tunstall, Helena

    2012-08-01

    Most research on the phenomenon of "brain drain" (one-way flow of highly skilled/educated individuals) has focused on movement between the least developed and most highly developed countries. Therefore, the significance of patterns of migration to middle-income countries such as those in Latin America is less clear. The aim of this study was to outline key features of international health worker "brain drain" to Chile to promote discussion and further research on this phenomenon as it pertains to the Latin American region. The study compared immigrant health workers living in Chile to both Chilean-born health workers and other immigrants living in Chile using a qualitative nationwide dataset (the results of Chile's 2009 National Socioeconomic Characterization Survey). Demographic, socioeconomic, and health-related variables were included in the analyses, which were weighted by population to obtain nationally representative estimates. In 2009, immigrant health workers represented 2.2% of all health personnel and 2.6% of all resident immigrants in the country. While most immigrant health workers had a universitylevel education, about 25% had only a high school-level education or less. There was no statistically significant difference between the distribution of immigrant health workers' household income and that of Chilean-born health workers. A significantly higher proportion of the immigrant group reported no entitlement to health care provision. While the results of this study do not indicate a significant international health worker "brain drain" to Chile, they do suggest distinctive patterns of migration within the Latin American region. Future studies in Chile could confirm the validity of these results, using a larger sample of immigrant health workers.

  19. Role of wound instillation with bupivacaine through surgical drains for postoperative analgesia in modified radical mastectomy

    Directory of Open Access Journals (Sweden)

    Nirmala Jonnavithula

    2015-01-01

    Full Text Available Background and Aims: Modified Radical Mastectomy (MRM is the commonly used surgical procedure for operable breast cancer, which involves extensive tissue dissection. Therefore, wound instillation with local anaesthetic may provide better postoperative analgesia than infiltration along the line of incision. We hypothesised that instillation of bupivacaine through chest and axillary drains into the wound may provide postoperative analgesia. Methods: In this prospective randomised controlled study 60 patients aged 45-60 years were divided into three groups. All patients were administered general anaesthesia. At the end of the surgical procedure, axillary and chest wall drains were placed before closure. Group C was the control with no instillation; Group S received 40 ml normal saline, 20 ml through each drain; and Group B received 40 ml of 0.25% bupivacaine and the drains were clamped for 10 min. After extubation, pain score for both static and dynamic pain was evaluated using visual analog scale and then 4 th hourly till 24 h. Rescue analgesia was injection tramadol, if the pain score exceeds 4. Statistical analysis was performed using SPSS version 13. Results : There was a significant difference in the cumulative analgesic requirement and the number of analgesic demands between the groups (P: 0.000. The mean duration of analgesia in the bupivacaine group was 14.6 h, 10.3 in the saline group and 4.3 h in the control group. Conclusion : Wound instillation with local anaesthetics is a simple and effective means of providing good analgesia without any major side-effects.

  20. A two dimensional analytical modeling of surface potential in triple metal gate (TMG) fully-depleted Recessed-Source/Drain (Re-S/D) SOI MOSFET

    Science.gov (United States)

    Priya, Anjali; Mishra, Ram Awadh

    2016-04-01

    In this paper, analytical modeling of surface potential is proposed for new Triple Metal Gate (TMG) fully depleted Recessed-Source/Dain Silicon On Insulator (SOI) Metal Oxide Semiconductor Field Effect Transistor (MOSFET). The metal with the highest work function is arranged near the source region and the lowest one near the drain. Since Recessed-Source/Drain SOI MOSFET has higher drain current as compared to conventional SOI MOSFET due to large source and drain region. The surface potential model developed by 2D Poisson's equation is verified by comparison to the simulation result of 2-dimensional ATLAS simulator. The model is compared with DMG and SMG devices and analysed for different device parameters. The ratio of metal gate length is varied to optimize the result.

  1. Improvement in the performance of graphene nanoribbon p-i-n tunneling field effect transistors by applying lightly doped profile on drain region

    Science.gov (United States)

    Naderi, Ali

    2017-12-01

    In this paper, an efficient structure with lightly doped drain region is proposed for p-i-n graphene nanoribbon field effect transistors (LD-PIN-GNRFET). Self-consistent solution of Poisson and Schrödinger equation within Nonequilibrium Green’s function (NEGF) formalism has been employed to simulate the quantum transport of the devices. In proposed structure, source region is doped by constant doping density, channel is an intrinsic GNR, and drain region contains two parts with lightly and heavily doped doping distributions. The important challenge in tunneling devices is obtaining higher current ratio. Our simulations demonstrate that LD-PIN-GNRFET is a steep slope device which not only reduces the leakage current and current ratio but also enhances delay, power delay product, and cutoff frequency in comparison with conventional PIN GNRFETs with uniform distribution of impurity and with linear doping profile in drain region. Also, the device is able to operate in higher drain-source voltages due to the effectively reduced electric field at drain side. Briefly, the proposed structure can be considered as a more reliable device for low standby-power logic applications operating at higher voltages and upper cutoff frequencies.

  2. Analytical model of nanoscale junctionless transistors towards controlling of short channel effects through source/drain underlap and channel thickness engineering

    Science.gov (United States)

    Roy, Debapriya; Biswas, Abhijit

    2018-01-01

    We develop a 2D analytical subthreshold model for nanoscale double-gate junctionless transistors (DGJLTs) with gate-source/drain underlap. The model is validated using well-calibrated TCAD simulation deck obtained by comparing experimental data in the literature. To analyze and control short-channel effects, we calculate the threshold voltage, drain induced barrier lowering (DIBL) and subthreshold swing of DGJLTs using our model and compare them with corresponding simulation value at channel length of 20 nm with channel thickness tSi ranging 5-10 nm, gate-source/drain underlap (LSD) values 0-7 nm and source/drain doping concentrations (NSD) ranging 5-12 × 1018 cm-3. As tSi reduces from 10 to 5 nm DIBL drops down from 42.5 to 0.42 mV/V at NSD = 1019 cm-3 and LSD = 5 nm in contrast to decrement from 71 to 4.57 mV/V without underlap. For a lower tSiDIBL increases marginally with increasing NSD. The subthreshold swing reduces more rapidly with thinning of channel thickness rather than increasing LSD or decreasing NSD.

  3. Processing method for drained water containing ethanol amine

    International Nuclear Information System (INIS)

    Wakuta, Kuniharu; Ogawa, Naoki; Sagawa, Hiroshi; Kamiyoshi, Hideki; Fukunaga, Kazuo; Iwamoto, Ken; Miki, Tsuyoshi; Hirata, Toshio

    1998-01-01

    Drained water containing ethanol amine is processed with microorganisms such as hydrazine resistant denitrification bacteria in a biodegrading vessel (A) in the coexistence of nitrous ions and/or nitric ions under an anaerobic condition, and then it is processed with microorganisms such as nitrification bacteria in another biotic oxidation vessel (B) under an aerobic condition to generate the coexistent nitrate ion and/or nitric ion, and returned to the biodegrading vessel (A). Further, they are exposed to air or incorporated with an oxidant and optionally a copper compound such as copper sulfate as a catalyst is added in a step of removing hydrazine. (T.M.)

  4. Modeling the long-term effect of winter cover crops on nitrate transport in artificially drained fields across the Midwest U.S.

    Science.gov (United States)

    A fall-planted cover crop is a management practice with multiple benefits including reducing nitrate losses from artificially drained fields. We used the Root Zone Water Quality Model (RZWQM) to simulate the impact of a cereal rye cover crop on reducing nitrate losses from drained fields across five...

  5. Noise performance in AlGaN/GaN HEMTs under high drain bias

    International Nuclear Information System (INIS)

    Pang Lei; Pu Yan; Lin Xinyu; Wang Liang; Liu Jian

    2009-01-01

    The advent of fully integrated GaN PA-LNA circuits makes it meaningful to investigate the noise performance under high drain bias. However, noise performance of AlGaN/GaN HEMTs under high bias has not received worldwide attention in theoretical studies due to its complicated mechanisms. The noise value is moderately higher and its rate of increase is fast with increasing high voltage. In this paper, several possible mechanisms are proposed to be responsible for it. Impact ionization under high electric field incurs great fluctuation of carrier density, which increases the drain diffusion noise. Besides, higher gate leakage current related shot noise and a more severe self-heating effect are also contributors to the noise increase at high bias. Analysis from macroscopic and microscopic perspectives can help us to design new device structures to improve noise performance of AlGaN/GaN HEMTs under high bias. (semiconductor devices)

  6. Origin of the water drained by the tunnel Graton; Origen de las aguas que drena el tunel Graton

    Energy Technology Data Exchange (ETDEWEB)

    Plata B, A [International Atomic Energy Agency, Vienna (Austria). Dept. of Research and Isotopes; Rojas M, R [Instituto Peruano de Energia Nuclear, Lima (Peru)

    1992-12-01

    The research of the origin of the water drained by the Graton tunnel was attempted using isotope techniques. During the period of studies (April 1989-October 1992), four field work was executed to sample waters for chemistry, stable isotope and Tritium analysis, an to inject tracers and verify the possible infiltration from the Rimac and Blanco rivers to the tunnel. The results of the stable isotope analysis show that the water drained by the Graton tunnel comes from a basin around 300 meters above the average altitude of the basin where the Graton is located. The Tritium analysis show that the water is relatively modern. Using the model of total mixing, the residence times of the water drained at the km 0.5 and 2.5 are in the order to 45 years. The conductivities of the water of the tunnel is higher than the Rimac river ones because the influence of mine water. The chemical analysis of the water sampled at the downstream end of the tunnel, show that the conservative ions of the water kept almost constant during more than two years. The results of the work with artificial tracer show that there is no significant leakage from the Rimac and Blanco rivers to the Graton tunnel. So far, it can be concluded as a preliminary approach that the Graton tunnel drains relatively modern water originated in another basin. The hydrodynamics of the area of study seems to include a large storage on underground water in the system. The topography, geology and isotopic composition of the water samples, points to the upper Mantaro river basin as the possible source of part of the water drained by the Graton tunnel. (authors). 20 p. 2 figs., 7 ills., 4 tabs.

  7. The effect of drains on the seepage of contaminants from subgrade tailings disposal areas

    International Nuclear Information System (INIS)

    Witten, A.J.; Pin, F.G.; Sharp, R.D.

    1984-01-01

    A numerical simulation study is performed to investigate the influence of ponded water and a bottom drain on the pathways for contaminant migration from a subgrade uranium mill tailings disposal pit. A numerical model is applied to a generic disposal pit constructed with a bottom clay liner and steep unlined sidewalls. The migration of a two-contaminant system is modeled assuming that neither contaminant decays and only one contaminant is retarded. Two dominant pathways are indentified; one associated with lateral sidewall leakage and the other associated with transport through the bottom clay liner. It is found that the drain serves to reduce migration through the sidewall which, in turn, prevents the retarded contaminant from reaching the aquifer. The ponded water provides increased head which causes an accelarated vertical movement of moisture through the clay liner

  8. Characteristics of drain-modulated generation current in n-type metal-oxide-semiconductor field-effect transistor

    International Nuclear Information System (INIS)

    Chen Hai-Feng; Guo Li-Xin; Zheng Pu-Yang; Dong Zhao; Zhang Qian

    2015-01-01

    Drain-modulated generation current I DMG induced by interface traps in an n-type metal-oxide-semiconductor field-effect transistor (nMOSFET) is investigated. The formation of I DMG ascribes to the change of the Si surface potential φ s . This change makes the channel suffer transformation from the inversion state, depletion I state to depletion II state. The simulation result agrees with the experiment in the inversion and depletion I states. In the depletion II state, the theoretical curve goes into saturation, while the experimental curve drops quickly as V D increases. The reason for this unconformity is that the drain-to-gate voltage V DG lessens φ s around the drain corner and controls the falling edge of the I DMG curve. The experiments of gate-modulated generation and recombination currents are also applied to verify the reasonability of the mechanism. Based on this mechanism, a theoretical model of the I DMG falling edge is set up in which I DMG has an exponential attenuation relation with V DG . Finally, the critical fitting coefficient t of the experimental curves is extracted. It is found that t = 80 mV = 3kT/q. This result fully shows the accuracy of the above mechanism. (paper)

  9. The value of cholangiography through Jackson-Pratt drains in the management of postoperative biliary injuries.

    Science.gov (United States)

    Macedo, Francisco Igor B; Casillas, Victor J; Davis, James S; Levi, Joe U; Sleeman, Danny

    2014-01-01

    Iatrogenic biliary injury is the most significant complication after laparoscopic cholecystectomy. We present our experience with an alternative diagnostic approach using transcatheter cholangiography (TCC) through a Jackson-Pratt (JP) drain and discuss potential benefits and limitations of the technique. From March 2002 to February 2012, 40 patients with major postoperative biliary injury underwent biliary reconstruction at our institution. Mean age was 51.7 ± 18.1 years (range, 19 to 86 years) with 30 (75%) females. Seventeen (42.5%) injuries were detected intraoperatively and in 13 (32.5%) cases, JP drains were placed for biliary drainage. Lesions were classified according to Bismuth grade: I (10 patients [25%]), II (10 patients [25%]), III (six patients [15%]), IV (10 patients [25%]), and V (four patients [10%]). TCC was performed in seven patients with JP drains (53.8%). It fully defined the injury site in three cases of limited magnetic resonance cholangiopancreatography (MRCP) such as common hepatic duct and common bile duct leaks and in four cases (57.1%) that endoscopic retrograde cholangiopancreatography (ERCP) was limited as a result of clipping of the distal common bile duct. TCC showed promising results in cases of limited MRCP and ERCP such as fistulous orifices or leakage. It may represent an alternative adjunct in the diagnostic armamentarium of complex biliary injuries.

  10. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    Science.gov (United States)

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  11. Stable carbon and nitrogen isotopes in vertical peat profiles of natural and drained boreal peatlands

    Science.gov (United States)

    Nykänen, Hannu; Mpamah, Promise; Rissanen, Antti; Pitkänen, Aki; Turunen, Jukka; Simola, Heikki

    2015-04-01

    Peatlands form a significant carbon pool in the global carbon cycle. Change in peat hydrology, due to global warming is projected to change microbiological processes and peat carbon pool. We tested if bulk stable carbon and nitrogen isotopes serve as indicators of severe long term drying in peatlands drained for forestry. Depth profile analysis of peat, for their carbon and nitrogen content as well as their carbon and nitrogen stable isotopic signatures, were conducted for peatlands in southern and eastern Finland, having ombrotrophic and minerotrophic natural and corresponding drained pairs or separate drained sites. The selection of sites allowed us to compare changes due to different fertility and changes due to long term artificial drying. Drainage lasting over 40 years has led to changes in hydrology, vegetation, nutrient mineralization and respiration. Furthermore, increased nutrient uptake and possible recycling of peat nitrogen and carbon trough vegetation back to the peat surface, also possibly has an effect on the stable isotopic composition of peat carbon and nitrogen. We think that drainage induced changes somehow correspond to those caused by changed hydrology due to climate change. We will present data from these measurements and discuss their implications for carbon and nitrogen flows in peatlands.

  12. Selenium in aquatic biota inhabiting agricultural drains in the Salton Sea Basin, California

    Science.gov (United States)

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2012-01-01

    Resource managers are concerned that water conservation practices in irrigated farmlands along the southern border of the Salton Sea, Imperial County, California, could increase selenium concentrations in agricultural drainwater and harm the desert pupfish (Cyprinodon macularius), a federally protected endangered species. As part of a broader attempt to address this concern, we conducted a 3-year investigation to collect baseline information on selenium concentrations in seven agricultural drains inhabited by pupfish. We collected water, sediment, selected aquatic food-chain taxa (particulate organic detritus, filamentous algae, net plankton, and midge [Chironomidae] larvae), and two poeciliid fishes (western mosquitofish Gambusia affinis and sailfin molly Poecilia latipinna) for selenium determinations. The two fish species served as ecological surrogates for pupfish, which we were not permitted to sacrifice. Dissolved selenium ranged from 0.70 to 32.8 μg/L, with selenate as the major constituent. Total selenium concentrations in other environmental matrices varied widely among drains, with one drain (Trifolium 18) exhibiting especially high concentrations in detritus, 5.98–58.0 μg Se/g; midge larvae, 12.7–50.6 μg Se/g; mosquitofish, 13.2–20.2 μg Se/g; and mollies, 12.8–30.4 μg Se/g (all tissue concentrations are based on dry weights). Although toxic thresholds for selenium in fishes from the Salton Sea are still poorly understood, available evidence suggests that ambient concentrations of this element may not be sufficiently elevated to adversely affect reproductive success and survival in selenium-tolerant poeciliids and pupfish.

  13. Selenium in aquatic biota inhabiting agricultural drains in the Salton Sea Basin, California.

    Science.gov (United States)

    Saiki, Michael K; Martin, Barbara A; May, Thomas W

    2012-09-01

    Resource managers are concerned that water conservation practices in irrigated farmlands along the southern border of the Salton Sea, Imperial County, California, could increase selenium concentrations in agricultural drainwater and harm the desert pupfish (Cyprinodon macularius), a federally protected endangered species. As part of a broader attempt to address this concern, we conducted a 3-year investigation to collect baseline information on selenium concentrations in seven agricultural drains inhabited by pupfish. We collected water, sediment, selected aquatic food-chain taxa (particulate organic detritus, filamentous algae, net plankton, and midge [Chironomidae] larvae), and two poeciliid fishes (western mosquitofish Gambusia affinis and sailfin molly Poecilia latipinna) for selenium determinations. The two fish species served as ecological surrogates for pupfish, which we were not permitted to sacrifice. Dissolved selenium ranged from 0.70 to 32.8 μg/L, with selenate as the major constituent. Total selenium concentrations in other environmental matrices varied widely among drains, with one drain (Trifolium 18) exhibiting especially high concentrations in detritus, 5.98-58.0 μg Se/g; midge larvae, 12.7-50.6 μg Se/g; mosquitofish, 13.2-20.2 μg Se/g; and mollies, 12.8-30.4 μg Se/g (all tissue concentrations are based on dry weights). Although toxic thresholds for selenium in fishes from the Salton Sea are still poorly understood, available evidence suggests that ambient concentrations of this element may not be sufficiently elevated to adversely affect reproductive success and survival in selenium-tolerant poeciliids and pupfish.

  14. Lawps ion exchange column gravity drain of spherical resorcinol formaldehyde resin

    Energy Technology Data Exchange (ETDEWEB)

    Duignan, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Herman, D. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Restivo, M. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-01-28

    Experiments at several different scales were performed to understand the removal of spherical resorcinol formaldehyde (sRF) ion exchange resin using a gravity drain system with a valve located above the resin screen in the ion exchange column (IXC). This is being considered as part of the design for the Low Activity Waste Pretreatment System (LAWPS) to be constructed at the DOE Hanford Site.

  15. Interpretation of Cone Penetration Testing in Silty Soils Conducted under Partially Drained Conditions

    DEFF Research Database (Denmark)

    Holmsgaard, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2016-01-01

    The standard penetration rate used in cone penetration tests (CPTs) is 20 mm=s, regardless of soil type, which yields fully drained penetration in sand and fully undrained penetration in clay. However, for silty soils that represent an intermediate grain size composition and unique characteristic...

  16. State of science of phosphorus modeling in tile drained agricultural systems using APEX

    Science.gov (United States)

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  17. Improvised external ventricular drain in neurosurgery: A Nigerian tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    O A Ojo

    2015-01-01

    Full Text Available Background: The most common type of hydrocephalus in developing countries is post infective hydrocephalus. Infected cerebrospinal fluid (CSF however cannot be shunted for the reason that it will block the chamber of the ventriculo-peritoneal (VP shunt due to its high protein content. In centers where standard external ventricular drain (EVD sets are not available, improvised feeding tube can be used. Aim: The main focus of this study is to encourage the use of improvised feeding tube catheters for EVD when standard sets are not available to improve patients′ survival. Methodology: This was a prospective study. Consecutive patients with hydrocephalus that cannot be shunted immediately for high chances of shunt failure or signs of increasing intracranial pressure were recruited into the study. Other inclusion criteria were preoperative brain tumor with possibility of blocked CSF pathway and massive intraventricular hemorrhage necessitating ventricular drainage as a salvage procedure. Standard EVD set is not readily available and too expensive for most of the parents to afford. Improvised feeding tube is used to drain/divert CSF using the standard documented procedure for EVD insertion. Outcome is measured and recorded. Results: A total of 28 patients were recruited into the study over a time frame of 2 years. There were 19 (67.9% male and 9 (32.1% females with a ratio of about 2:1. Age ranges varied from as low as 7 days to 66 years. The median age of the study sample was 6.5 months while the mean was 173.8 months. Duration of EVD varied from 2 days to 11 days with a median of 7 while the average was 6 days. Eventual outcome following the procedure of EVD showed that 19 (67.9% survived and were discharged either to go home or to have VP shunt afterwards while 8 (28.6% of the patients died. Conclusions: External ventricular drain can and should be done when it is necessary. Potential mortalities could be reduced by the improvised drainage using a

  18. Improvised external ventricular drain in neurosurgery: A Nigerian tertiary hospital experience.

    Science.gov (United States)

    Ojo, O A; Asha, M A; Bankole, O B; Kanu, O O

    2015-01-01

    The most common type of hydrocephalus in developing countries is post infective hydrocephalus. Infected cerebrospinal fluid (CSF) however cannot be shunted for the reason that it will block the chamber of the ventriculo-peritoneal (VP) shunt due to its high protein content. In centers where standard external ventricular drain (EVD) sets are not available, improvised feeding tube can be used. The main focus of this study is to encourage the use of improvised feeding tube catheters for EVD when standard sets are not available to improve patients' survival. This was a prospective study. Consecutive patients with hydrocephalus that cannot be shunted immediately for high chances of shunt failure or signs of increasing intracranial pressure were recruited into the study. Other inclusion criteria were preoperative brain tumor with possibility of blocked CSF pathway and massive intraventricular hemorrhage necessitating ventricular drainage as a salvage procedure. Standard EVD set is not readily available and too expensive for most of the parents to afford. Improvised feeding tube is used to drain/divert CSF using the standard documented procedure for EVD insertion. Outcome is measured and recorded. A total of 28 patients were recruited into the study over a time frame of 2 years. There were 19 (67.9%) male and 9 (32.1%) females with a ratio of about 2:1. Age ranges varied from as low as 7 days to 66 years. The median age of the study sample was 6.5 months while the mean was 173.8 months. Duration of EVD varied from 2 days to 11 days with a median of 7 while the average was 6 days. Eventual outcome following the procedure of EVD showed that 19 (67.9%) survived and were discharged either to go home or to have VP shunt afterwards while 8 (28.6%) of the patients died. External ventricular drain can and should be done when it is necessary. Potential mortalities could be reduced by the improvised drainage using a standard feeding tube as described.

  19. Improvised external ventricular drain in neurosurgery: A Nigerian tertiary hospital experience

    Science.gov (United States)

    Ojo, O. A.; Asha, M. A.; Bankole, O. B.; Kanu, O. O.

    2015-01-01

    Background: The most common type of hydrocephalus in developing countries is post infective hydrocephalus. Infected cerebrospinal fluid (CSF) however cannot be shunted for the reason that it will block the chamber of the ventriculo-peritoneal (VP) shunt due to its high protein content. In centers where standard external ventricular drain (EVD) sets are not available, improvised feeding tube can be used. Aim: The main focus of this study is to encourage the use of improvised feeding tube catheters for EVD when standard sets are not available to improve patients’ survival. Methodology: This was a prospective study. Consecutive patients with hydrocephalus that cannot be shunted immediately for high chances of shunt failure or signs of increasing intracranial pressure were recruited into the study. Other inclusion criteria were preoperative brain tumor with possibility of blocked CSF pathway and massive intraventricular hemorrhage necessitating ventricular drainage as a salvage procedure. Standard EVD set is not readily available and too expensive for most of the parents to afford. Improvised feeding tube is used to drain/divert CSF using the standard documented procedure for EVD insertion. Outcome is measured and recorded. Results: A total of 28 patients were recruited into the study over a time frame of 2 years. There were 19 (67.9%) male and 9 (32.1%) females with a ratio of about 2:1. Age ranges varied from as low as 7 days to 66 years. The median age of the study sample was 6.5 months while the mean was 173.8 months. Duration of EVD varied from 2 days to 11 days with a median of 7 while the average was 6 days. Eventual outcome following the procedure of EVD showed that 19 (67.9%) survived and were discharged either to go home or to have VP shunt afterwards while 8 (28.6%) of the patients died. Conclusions: External ventricular drain can and should be done when it is necessary. Potential mortalities could be reduced by the improvised drainage using a standard

  20. Comparison of export dynamics of nutrients and animal-borne estrogens from a tile-drained Midwestern agroecosystem.

    Science.gov (United States)

    Gall, Heather E; Sassman, Stephen A; Jenkinson, Byron; Lee, Linda S; Jafvert, Chad T

    2015-04-01

    Concentrated animal feeding operations (CAFOs) are known to be a source of nutrients and hormones found in surface water bodies around the world. While the fate and transport of nutrients have been studied for decades, much less research has been conducted on the fate and transport of hormones. To facilitate a comparison of nutrient and hormone export dynamics from farm fields, nitrate + nitrite (N), dissolved reactive phosphorus (DRP), 17α- and 17β-estradiol (E2), estrone (E1), and estriol (E3) were monitored in a tile drain and receiving ditch for one year on a working farm in north central Indiana. Repeated animal waste applications led to high frequency detection of hormones (>50% in tile drain; >90% in the ditch) and nutrients (>70% for DRP; 100% for N). Hydrologic variability was found to be a dominant factor controlling export of N, DRP, and E1 to the drain and ditch. Of the estrogens, the temporal trend in E1 export was most similar to that of DRP. Differences in temporal export between P and the other estrogens likely were due to differences in the biogeochemical processes that affect their fate and transport within the agroecosystem. During short periods when the flowrate exceeded the 80(th) percentile for the year, over 70% of the total mass export of DRP and E1 occurred for the year in both the tile drain and ditch, demonstrating the importance of high-flow events. Therefore, best management practices must be effective during large flow events to substantially reduce transport to downstream locations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Diminishing peat oxidation of agricultural peat soils by infiltration via submerged drains

    NARCIS (Netherlands)

    Akker, van den J.J.H.; Hendriks, R.F.A.

    2017-01-01

    Oxidation of peat soils used in dairy farming in the western peat area of The Netherlands causes subsidence rates up to 13 mm.y and emissions of CO2 to about 27 t.ha.y. In 2003 experiments started with subsurface irrigation by submerged drains to raise groundwater levels to reduce oxidation and so

  2. Thermal-hydraulic analysis of bayonet cooling thimble in fuel drain tank of ORNL 10 MW MSRE

    International Nuclear Information System (INIS)

    Sun Lu; Sun Licheng; Yan Changqi

    2012-01-01

    The residual heat removal system of molten salt reactor designed by ORNL, using molten salt as fuel and draining the fuel into fuel drain tank after shutdown of the reactor, removes the decay heat by the circulation of water through the bayonet cooling thimbles in the fuel drain tank. According to structural features of the bayonet cooling thimbles in ORNL 10 MW molten salt reactor experiment (MSRE), this paper presents the analytical results of the influence of the width of gas gap and the width of steam riser on the heat removal ability and the natural circulation of the cooling water, etc. The analysis results show that, when the width of gas gap range from 3.1 mm to 5.1 mm, the change of heat dissipation power and natural circulation flow rate are both less than 5%; when the width of steam riser changes from 3.6 mm to 5.1 mm, the flow mass of the natural circulation change from 1.9 kg/s to 4.79 kg/s, with a slightly effect on the heat transfer efficiency of the system. (authors)

  3. Effect of asymmetrical double-pockets and gate-drain underlap on Schottky barrier tunneling FET: Ambipolar conduction vs. high frequency performance

    Science.gov (United States)

    Shaker, Ahmed; Ossaimee, Mahmoud; Zekry, A.

    2016-08-01

    In this paper, a proposed structure based on asymmetrical double pockets SB-TFET with gate-drain underlap is presented. 2D extensive modeling and simulation, using Silvaco TCAD, were carried out to study the effect of both underlap length and pockets' doping on the transistor performance. It was found that the underlap from the drain side suppresses the ambipolar conduction and doesn't enhance the high-frequency characteristics. The enhancement of the high-frequency characteristics could be realized by increasing the doping of the drain pocket over the doping of the source pocket. An optimum choice was found which gives the conditions of minimum ambipolar conduction, maximum ON current and maximum cut-off frequency. These enhancements render the device more competitive as a nanometer transistor.

  4. Performance optimization of MOS-like carbon nanotube-FETs with realistic source/drain contacts based on electrostatic doping

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Hailiang; Zhang Minxuan [School of Computer, National University of Defense Technology, Changsha 410073 (China); Hao Yue, E-mail: hlzhou@nudt.edu.cn [School of Microelectronics, Xidian University, Xi' an 710071 (China)

    2010-12-15

    Due to carrier band-to-band-tunneling (BTBT) through channel-source/drain contacts, conventional MOS-like Carbon Nanotube Field Effect Transistors (C-CNFETs) suffer from ambipolar conductance, which deteriorates the device performance greatly. In order to reduce such ambipolar behavior, a novel device structure based on electrostatic doping is proposed and all kinds of source/drain contacting conditions are considered in this paper. The non-equilibrium Green's function (NEGF) formalism based simulation results show that, with proper choice of tuning voltage, such electrostatic doping strategy can not only reduce the ambipolar conductance but also improve the sub-threshold performance, even with source/drain contacts being of Schottky type. And these are both quite desirable in circuit design to reduce the system power and improve the frequency as well. Further study reveals that the performance of the proposed design depends strongly on the choice of tuning voltage value, which should be paid much attention to obtain a proper trade-off between power and speed in application. (semiconductor devices)

  5. Retention of Ag-specific memory CD4+ T cells in the draining lymph node indicates lymphoid tissue resident memory populations.

    Science.gov (United States)

    Marriott, Clare L; Dutton, Emma E; Tomura, Michio; Withers, David R

    2017-05-01

    Several different memory T-cell populations have now been described based upon surface receptor expression and migratory capabilities. Here we have assessed murine endogenous memory CD4 + T cells generated within a draining lymph node and their subsequent migration to other secondary lymphoid tissues. Having established a model response targeting a specific peripheral lymph node, we temporally labelled all the cells within draining lymph node using photoconversion. Tracking of photoconverted and non-photoconverted Ag-specific CD4 + T cells revealed the rapid establishment of a circulating memory population in all lymph nodes within days of immunisation. Strikingly, a resident memory CD4 + T cell population became established in the draining lymph node and persisted for several months in the absence of detectable migration to other lymphoid tissue. These cells most closely resembled effector memory T cells, usually associated with circulation through non-lymphoid tissue, but here, these cells were retained in the draining lymph node. These data indicate that lymphoid tissue resident memory CD4 + T-cell populations are generated in peripheral lymph nodes following immunisation. © 2017 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Sediment and Nutrient Contributions from Subsurface Drains and Point Sources to an Agricultural Watershed

    Directory of Open Access Journals (Sweden)

    Bonnie Ball Coelho

    2010-03-01

    Full Text Available Excess sediment and nutrients in surface waters can threaten aquatic life. To determine the relative importance of subsurface drainage as a pathway for movement of sediment and nutrients to surface waters, loading from various tile systems was compared to that from sewage treatment plants (STP within the same watershed. Movement through tiles comprised 1 to 8% of estimated total (overland plus tile annual sediment loading from the respective areas drained by the tile. Load during the growing season from five closed drain- age systems without surface inlets averaged 5 kg sediment/ha, 0.005 kg dissolved reactive P (DRP/ha, 0.003 kg NH4-N/ha, and 3.8 kg NO3-N/ha; and from two open drainage systems with surface inlets averaged 14 kg sediment/ha, 0.03 kg DRP/ha, 0.04 kg NH4-N/ha, and 3.1 kg NO3-N/ha. The eight STP contributed about 44 530 kg suspended sediments, 3380 kg total P, 1340 kg NH4-N, and 116 900 kg NO3-N to the watershed annually. Drainage systems added less NH4-N and P, but more NO3-N and suspended solids to surface waters than STP. Tile drainage pathways for NO3-N, STP in the case of P, and overland pathways for sediment are indicated as targets to control loading in artificially drained agricultural watersheds.

  7. Newcomen's Fire Bomb nd other Draining Devices: An Attempt to Transfer British Technology to the New Spain Mining Industry, 1726-1731

    Directory of Open Access Journals (Sweden)

    Carlos Sempat Assadourian

    2001-01-01

    Full Text Available Groundwater floods were probably the worse risk in colonial silver mining, because of the high costs of draining or because the floods which could not be  drained forced workers to  eave important silver deposits. During the seventeenth century, the machines used in New Spain for draining groundwater were very inferior to those used in England or Germany. This  essay analyzes a prívate colonial attempt, in the 1720's, to obtain the Newcomen fire bomb and other European devices, which would prove  more  efficient  than local ones. One  obvious obstacle to technological transference  is the  suspicious behavior of the people involved in such projects.

  8. Occurrence and seasonal variations of per- and polyfluoroalkyl substances (PFASs) including fluorinated alternatives in rivers, drain outlets and the receiving Bohai Sea of China.

    Science.gov (United States)

    Chen, Hong; Han, Jianbo; Zhang, Can; Cheng, Jiayi; Sun, Ruijun; Wang, Xiaomeng; Han, Gengchen; Yang, Wenchao; He, Xin

    2017-12-01

    A simultaneous sampling campaign was undertaken to study the pollution by 21 per- and polyfluoroalkyl substances (PFASs) in rivers, drain outlets and their receiving Bohai Sea of China. Chlorinated polyfluoroalkyl ether sulfonic acids (Cl-PFESAs) are being used as fluorinated alternatives and they were included in this study. In comparison with other regions and countries, high concentrations of ∑ 21 PFASs in seawater samples from the Bohai Sea, ranging from 5.03 to 41 700 ng/L (median: 64.8 ng/L), were observed. The spatial distribution of PFAS levels in this sea area was in the ranking of Laizhou Bay > Liaodong Bay > Bohai Bay > other sea areas. By comparing the levels and composition profiles of PFASs in the seawater and their sources (rivers and drain outlets), it was concluded that rivers and drain outlets are the primary sources of PFAS contamination to the Bohai Sea. These PFAS levels varied seasonally among the rivers and drain outlets, but statistically significant changes were not observed. Levels of 6:2 and 8:2 Cl-PFESAs in rivers, drain outlets and receiving sea were firstly reported in the present study. Relatively high concentrations of 6:2 Cl-PFESA were found in drain outlets, ranging from below method limits of quantification (MLQ) to 7600 ng/L, but 8:2 Cl-PFAES detection was infrequent and all median concentration below MLQ. Mass discharges to the sea of 6:2 Cl-PFESA from rivers and drain outlets to the sea were estimated to be 37 and 17 kg/y, respectively. Copyright © 2017. Published by Elsevier Ltd.

  9. Fibredrain method. Environmentally friendly vertical drain; Fiberdrain koho. Kankyo ni yasashii vertical drain koho

    Energy Technology Data Exchange (ETDEWEB)

    Suto, Y.; Inoue, T. [Fukken Co. Ltd., Hiroshima (Japan); Miura, N. [Saga University, Saga (Japan). Faculty of Science and Engineering; Yoshida, Y.; Hamada, K. [Hiroshima Prefectural Government Office, Hiroshima (Japan); Aboshi, H. [Hiroshima University, Hiroshima (Japan)

    1997-11-01

    Ground improvement using fibredrain (FD) material has not been used in Japan. For its practical use in Japan, laboratory experiment was made on such technological characteristics of FD material as tensile strength and permeability, and field test was also made to verify its improvement effect. A plane FD specimen of nearly 90mm wide and 9mm thick is composed of a folded double jute fabrics band and 4 twisted coir ropes arranged between the jute fabrics at even intervals, and the band is sewn up along center lines between the ropes. A mean permeability coefficient is estimated to be {kappa} = 1.0times10{sup -1}cm/s and {kappa} = 1.0times10{sup -2}cm/s at {sigma}{sup 3} = 0.5kgf/cm{sup 2} and {sigma}{sup 3} = 2.0kgf/cm{sup 2} in lateral pressure, respectively, showing sufficient permeabilities for vertical drain material. The tensile strength of fresh FD material is estimated to be a little stronger than 900kg/material width which is far stronger than that of conventional FD materials. The field test result showed that the FD material achieved the target for ground improvement, and has sufficient functions as a substitute for SD material. 6 refs., 10 figs.

  10. Drained Lava Tubes and Lobes From Eocretaceous Paraná-Etendeka Province, Brazil

    Science.gov (United States)

    Waichel, B. L.; Lima, E. F. D.; Mouro, L. D.; Briske, D. R.; Tratz, E. B.

    2017-12-01

    The identification of lava tubes in continental flood basalt provinces (CFBP) is difficult and reports of preserved drained tubes and lobes are rare. The large extension of CFBP must be related to an efficient transport of lava and tubes are the most efficient mechanism to transport lava in insulated pathways, like observed in modern volcanic fields. Looking for caves in the central portion of Paraná-Etendeka Province, we discovered drained lava tubes (4) and lobes (6) in a volcanic sequence constituted by pahoehoe flows. Lava tubes are: Casa de Pedra, Perau Branco, Dal Pae and Pinhão. The Casa de Pedra tube system is composed of two principal chambers with similar dimensions, reaching up to 10 m long and 4.0 m high connected by a narrow passage. The general form of the chamber is hemispherical, with re-entrances of ellipsoidal shape probably formed by small lava lobes and collapse structures in the roof. The second chamber is connected with three secondary lava tubes. Columns in the cave are formed when the flowing lava separates in two lava channels that join again further down the system, forming and anastomosing tube network. Lateral lava benches and lava drainings at the walls are observed in secondary tubes. The general lava flow is to SW. The Perau Branco system is composed of five tubes with ellipsoidal openings. The main features are the long tubes that emerge from the small flattened chambers. One tube is more than 20 m long, with alternating circular and flattened ellipsoidal sections. The general lava flow is to NE. Pinhão tube is spherical with 3 meters diameter and 15 m long, with lava flow orientation to NW. This tube has a bottleneck shape with linings (up to 3 cm thick), which are observed in the roof and walls. Dal Pae Tube is 10 m long with an ellipsoidal opening, bottleneck shape and orientation to NE. The lava flow directions measured in the tubes is to SW (Casa de Pedra, Pinhão) and NE (Perau Branco, Dal Pae) and this pattern is related to

  11. Right superior vena cava draining into the left atrium

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); Batisse, Alain [Institut de Puericulture et de Perinatalogie, Paris (France); Vouhe, Pascal [University Rene Descartes-Paris 5, Department of Paediatric Cardiac Surgery, Hopital Necker-Enfants Malades, Paris (France); Ou, Phalla [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker-Enfants Malades, Paris (France)

    2008-08-15

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  12. Right superior vena cava draining into the left atrium

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien; Batisse, Alain; Vouhe, Pascal; Ou, Phalla

    2008-01-01

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  13. Bio-treatment system of oily bilge drained from ship engine room; Hakuyo kikanshitsu haishutsu bilge no bio shori system

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H.; Zaitsu, A.; Nobeyama, N.; Hirata, T. [Mitsubishi Heavy Industries, Ltd., Tokyo (Japan)

    1995-11-01

    We aimed to develop a system for treating emulsified oil discharged from ship engine rooms. The efficiency of the system aimed at reducing the oil content of the drain to 15ppm or less so that the drain might be discharged into the sea. We have succeeded in developing a biological treatment system using the fluidized bed in which the drain and sludge are efficiently mixed by aeration and stirring. The specific sludge with enhanced oil decomposing ability is used in the system. We performed on - shipboard tests using a pilot test system, whose capacity of the reaction chamber is 0.5m{sup 3} and oil volume load, 0.4kg-oil/m{sup 3}/d, and have confirmed future possible applications to the treatment system for ships. This would bring great reduction in loads on the existing oil separator, saving its maintenance cost in general. 9 refs., 8 figs.

  14. A study on the degradation mechanism of InGaZnO thin-film transistors under simultaneous gate and drain bias stresses based on the electronic trap characterization

    International Nuclear Information System (INIS)

    Jeong, Chan-Yong; Lee, Daeun; Song, Sang-Hun; Kwon, Hyuck-In; Kim, Jong In; Lee, Jong-Ho

    2014-01-01

    We discuss the device degradation mechanism of amorphous indium–gallium–zinc oxide (a-IGZO) thin-film transistors (TFTs) under simultaneous gate and drain bias stresses based on the electronic trap characterization results. The transfer curve exhibits an apparent negative shift as the stress time increases, and a formation of hump is observed in the transfer curve after stresses. A notable increase of the frequency dispersion is observed after stresses in both gate-to-drain capacitance–voltage (C GD –V G ) and gate-to-source capacitance–voltage (C GS –V G ) curves, which implies that the subgap states are generated by simultaneous gate and drain bias stresses, and the damaged location is not limited to the drain side of TFTs. The larger frequency dispersion is observed in C GD –V G  curves after stresses in a wider channel device, which implies that the heat is an important factor in the generation of the subgap states under simultaneous gate and drain bias stresses in a-IGZO TFTs. Based on the electronic trap characterization results, we conclude that the impact ionization near the drain side of the device is not a dominant mechanism causing the generation of subgap states and device degradation in a-IGZO TFTs under simultaneous gate and drain bias stresses. The generation of oxygen vacancy-related donor-like traps near the conduction band edge is considered as a possible mechanism causing the device degradation under simultaneous gate and drain bias stresses in a-IGZO TFTs. (paper)

  15. A Worldwide Assessment of Greenhouse Gas Emissions from Drained Organic Soils

    Directory of Open Access Journals (Sweden)

    Francesco Nicola Tubiello

    2016-04-01

    Full Text Available Despite the importance of organic soils, including peatlands, in the global carbon cycle, detailed information on regional and global emissions is scarce. This is due to the difficulty to map, measure, and assess the complex dynamics of land, soil, and water interactions needed to assess the human-driven degradation of organic soils. We produced a new methodology for the comprehensive assessment of drained organic soils in agriculture and the estimation of the associated greenhouse gas emissions. Results indicated that over 25 million hectares of organic soils were drained worldwide for agriculture use, of which about 60% were in boreal and temperate cool areas, 34% in tropical areas, and 5% in warm temperate areas. Total emissions from the drainage were globally significant, totaling nearly one billion tonnes CO2eq annually. Of this, the CO2 component, about 780 million tonnes, represented more than one-fourth of total net CO2 emissions from agriculture, forestry, and land use. The bulk of these emissions came from a few tropical countries in Southeast Asia, and was linked to land clearing and drainage for crop cultivation. Geospatial data relative to this work were disseminated via the FAO geospatial server GeoNetwork, while the national aggregated statistics were disseminated via the FAOSTAT database.

  16. Refugee flow or brain-drain? The humanitarian policy and post-Tiananmen mainland Chinese immigration to Canada.

    Science.gov (United States)

    Liu X-f

    1997-03-01

    "The humanitarian policy that the Canadian government implemented in response to the 1989 Tiananmen Square crackdown changed a migration system primarily based on personal networks into a brain drain. Post-Tiananmen mainland Chinese immigrants (MCIs) were better educated than those arriving in Canada previously. Among the post-Tiananmen MCIs, those who landed under the policy were better educated than those landing in other categories. The analysis suggests that post-Tiananmen MCIs represented a brain-drain rather than a refugee flow, that the humanitarian policy implicitly contained ideological and human capital concerns in addition to humanitarian concerns, and that Canada benefited from the policy by obtaining human capital as well as satisfying its humanitarian obligations and ideological aspirations." excerpt

  17. Interior drains for open pit disposal of uranium mill tailings

    International Nuclear Information System (INIS)

    Staub, W.P.

    1978-01-01

    A conceptualized interior drainage system is presented for reducing the environmental impact on natural groundwater by disposal of uranium mill tailings in the mined-out open pit. The evaporation/seepage ratio can be increased through the use of interior drains, long-term monitoring of groundwater quality can be eliminated, and the open pit will not require an extensive liner. Other advantages not related to groundwater are: control of fugitive dust and radon emanation during mill operations and timely reclamation after the impoundment is filled with tailings

  18. Potential depletion of surface water in the Colorado River and agricultural drains by groundwater pumping in the Parker-Palo Verde-Cibola area, Arizona and California

    Science.gov (United States)

    Leake, Stanley A.; Owen-Joyce, Sandra J.; Heilman, Julian A.

    2013-01-01

    Water use along the lower Colorado River is allocated as “consumptive use,” which is defined to be the amount of water diverted from the river minus the amount that returns to the river. Diversions of water from the river include surface water in canals and water removed from the river by pumping wells in the aquifer connected to the river. A complication in accounting for water pumped by wells occurs if the pumping depletes water in drains and reduces measured return flow in those drains. In that case, consumptive use of water pumped by the wells is accounted for in the reduction of measured return flow. A method is needed to understand where groundwater pumping will deplete water in the river and where it will deplete water in drains. To provide a basis for future accounting for pumped groundwater in the Parker-Palo Verde-Cibola area, a superposition model was constructed. The model consists of three layers of finite-difference cells that cover most of the aquifer in the study area. The model was run repeatedly with each run having a pumping well in a different model cell. The source of pumped water that is depletion of the river, expressed as a fraction of the pumping rate, was computed for all active cells in model layer 1, and maps were constructed to understand where groundwater pumping depletes the river and where it depletes drains. The model results indicate that if one or more drains exist between a pumping well location and the river, nearly all of the depletion will be from drains, and little or no depletion will come from the Colorado River. Results also show that if a well pumps on a side of the river with no drains in the immediate area, depletion will come from the Colorado River. Finally, if a well pumps between the river and drains that parallel the river, a fraction of the pumping will come from the river and the rest will come from the drains. Model results presented in this report may be considered in development or refinement of strategies

  19. Test of a simplified modeling approach for nitrogen transfer in agricultural subsurface-drained catchments

    Science.gov (United States)

    Henine, Hocine; Julien, Tournebize; Jaan, Pärn; Ülo, Mander

    2017-04-01

    In agricultural areas, nitrogen (N) pollution load to surface waters depends on land use, agricultural practices, harvested N output, as well as the hydrology and climate of the catchment. Most of N transfer models need to use large complex data sets, which are generally difficult to collect at larger scale (>km2). The main objective of this study is to carry out a hydrological and a geochemistry modeling by using a simplified data set (land use/crop, fertilizer input, N losses from plots). The modelling approach was tested in the subsurface-drained Orgeval catchment (Paris Basin, France) based on following assumptions: Subsurface tile drains are considered as a giant lysimeter system. N concentration in drain outlets is representative for agricultural practices upstream. Analysis of observed N load (90% of total N) shows 62% of export during the winter. We considered prewinter nitrate (NO3) pool (PWNP) in soils at the beginning of hydrological drainage season as a driving factor for N losses. PWNP results from the part of NO3 not used by crops or the mineralization part of organic matter during the preceding summer and autumn. Considering these assumptions, we used PWNP as simplified input data for the modelling of N transport. Thus, NO3 losses are mainly influenced by the denitrification capacity of soils and stream water. The well-known HYPE model was used to perform water and N losses modelling. The hydrological simulation was calibrated with the observation data at different sub-catchments. We performed a hydrograph separation validated on the thermal and isotopic tracer studies and the general knowledge of the behavior of Orgeval catchment. Our results show a good correlation between the model and the observations (a Nash-Sutcliffe coefficient of 0.75 for water discharge and 0.7 for N flux). Likewise, comparison of calibrated PWNP values with the results from a field survey (annual PWNP campaign) showed significant positive correlation. One can conclude that

  20. The Nelaton Catheter Guard for Safe and Effective Placement of Subdural Drain for Two-Burr-Hole Trephination in Chronic Subdural Hematoma: A Technical Note.

    Science.gov (United States)

    Fichtner, Jens; Beck, Jürgen; Raabe, A; Stieglitz, Lennart Henning

    2015-09-01

    For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain. Georg Thieme Verlag KG Stuttgart · New York.

  1. Canine scent detection and microbial source tracking of human waste contamination in storm drains.

    Science.gov (United States)

    Van De Werfhorst, Laurie C; Murray, Jill L S; Reynolds, Scott; Reynolds, Karen; Holden, Patricia A

    2014-06-01

    Human fecal contamination of surface waters and drains is difficult to diagnose. DNA-based and chemical analyses of water samples can be used to specifically quantify human waste contamination, but their expense precludes routine use. We evaluated canine scent tracking, using two dogs trained to respond to the scent of municipal wastewater, as a field approach for surveying human fecal contamination. Fecal indicator bacteria, as well as DNA-based and chemical markers of human waste, were analyzed in waters sampled from canine scent-evaluated sites (urban storm drains and creeks). In the field, the dogs responded positively (70% and 100%) at sites for which sampled waters were then confirmed as contaminated with human waste. When both dogs indicated a negative response, human waste markers were absent. Overall, canine scent tracking appears useful for prioritizing sampling sites for which DNA-based and similarly expensive assays can confirm and quantify human waste contamination.

  2. Academic Brain Drain: Impact and Implications for Public Higher Education Quality in Kenya

    Science.gov (United States)

    Odhiambo, George O.

    2013-01-01

    The flight of human capital is a phenomenon that has been of concern to academics and development practitioners for decades. Unfortunately, there is no systematic record of the number of skilled professionals that many African countries have continued to lose to the developed world. Termed the "brain drain", it represents the loss of…

  3. Nutrient Concentrations and Stable Isotopes of Runoff from a Midwest Tile-Drained Corn Field

    Science.gov (United States)

    Wilkins, B. P.; Woo, D.; Li, J.; Michalski, G. M.; Kumar, P.; Conroy, J. L.; Keefer, D. A.; Keefer, L. L.; Hodson, T. O.

    2017-12-01

    Tile drains are a common crop drainage device used in Midwest agroecosystems. While efficient at drainage, the tiles provide a quick path for nutrient runoff, reducing the time available for microbes to use nutrients (e.g., NO3- and PO43-) and reduce export to riverine systems. Thus, understanding the effects of tile drains on nutrient runoff is critical to achieve nutrient reduction goals. Here we present isotopic and concentration data collected from tile drain runoff of a corn field located near Monticello, IL. Tile flow samples were measured for anion concentrations and stable isotopes of H2O and NO3-, while precipitation was measured for dual isotopes of H2O. Results demonstrate early tile flow from rain events have a low Cl- concentration (60% contribution) in the beginning of the hydrograph. As flow continues H2O isotopic values reflect pre-event water (ground and soil water), and Cl- concentrations increase representing a greater influence by matrix flow (60-90% contribution). Nitrate concentrations change dramatically, especially during the growing season, and do not follow a similar trend as the conservative Cl-, often decreasing days before, which represents missing nitrate in the upper surface portion of the soil. Nitrate isotopic data shows significant changes in 15N (4‰) and 18O (4‰) during individual hydrological events, representing that in addition to plant uptake and leaching, considerate NO3- is lost through denitrification. It is notable, that throughout the season d15N and d18O of nitrate change significantly representing that seasonally, substantial denitrification occurs.

  4. Vertical organic field effect phototransistor with two dissimilar source and drain contacts

    International Nuclear Information System (INIS)

    Woon, K.L.; Yeo, G.N.

    2014-01-01

    A solution processable vertical organic field effect phototransistor was fabricated using poly(3-hexylthiophene) and 1-(3-methoxycarbonyl)propyl-1-phenyl[6,6]C61 as the photo-active materials while poly(methyl methacrylate) is used as a dielectric layer. Interdigitated conductive poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) is used as a source and lithium flouride/aluminum as a drain. The device exhibits current modulation when the gate is positively biased. A significant photoeffect is observed in the reverse bias mode. Unlike conventional organic phototransistors, this device can operate at a zero source–drain bias with a photosensitivity and responsivity proportional to the gate voltage. A photosensitivity of up to 10 5 and a responsivity of up to 2 AW −1 are achieved in this mode. This effect is due to the presence of the weak photovoltaic behavior of this device. - Highlights: • A solution processable vertical field effect phototransistor is demonstrated. • Photosensitivity as high as ∼ 10 5 with responsivity of 2 AW −1 is achieved. • The gate can be used to modulate photocurrent with low leakage current. • The device shows weak photovoltaic behavior

  5. Effects of annealing gas and drain doping concentration on electrical properties of Ge-source/Si-channel heterojunction tunneling FETs

    Science.gov (United States)

    Bae, Tae-Eon; Wakabayashi, Yuki; Nakane, Ryosho; Takenaka, Mitsuru; Takagi, Shinichi

    2018-04-01

    Improvement in the performance of Ge-source/Si-channel heterojunction tunneling FETs (TFETs) with high on-current/off-current (I on/I off) ratio and steep subthreshold swing (SS) is demonstrated. In this paper, we experimentally examine the effects of gas ambient [N2 and forming gas (4% H2/N2)] and a doping concentration in the drain regions on the electrical characteristics of Ge/Si heterojunction TFETs. The minimum SS (SSmin) of 70.9 mV/dec and the large I on/I off ratio of 1.4 × 107 are realized by postmetallization annealing in forming gas. Also, the steep SSmin and averaged SS (SSavr) values of 64.2 and 78.4 mV/dec, respectively, are obtained in low drain doping concentration. This improvement is attributable to the reduction in interface state density (D it) in the channel region and to the low leakage current in the drain region.

  6. Dendritic Cell Migration to Skin-Draining Lymph Nodes Is Controlled by Dermatan Sulfate and Determines Adaptive Immunity Magnitude

    Directory of Open Access Journals (Sweden)

    Reza Nadafi

    2018-02-01

    Full Text Available For full activation of naïve adaptive lymphocytes in skin-draining lymph nodes (LNs, presentation of peptide:MHC complexes by LN-resident and skin-derived dendritic cells (DCs that encountered antigens (Ags is an absolute prerequisite. To get to the nearest draining LN upon intradermal immunization, DCs need to migrate from the infection site to the afferent lymphatics, which can only be reached by traversing a collagen-dense network located in the dermis of the skin through the activity of proteolytic enzymes. Here, we show that mice with altered collagen fibrillogenesis resulting in thicker collagen fibers in the skin display a reduced DC migration to the draining LN upon immune challenge. Consequently, the initiation of the cellular and humoral immune response was diminished. Ag-specific CD8+ and CD4+ T cells as well as Ag-specific germinal center B cells and serum immunoglobulin levels were significantly decreased. Hence, we postulate that alterations to the production of extracellular matrix, as seen in various connective tissue disorders, may in the end affect the qualitative outcome of adaptive immunity.

  7. Environmental impacts of alternative agricultural uses of poorly drained farm land in Ireland.

    Science.gov (United States)

    Sharma, Pooja; Humphreys, James; Holden, Nicholas M

    2018-05-07

    Abolition of the milk quota in the European Union and favourable market conditions have stimulated the expansion of the dairy sector in Ireland, causing more milk to be produced from poorly drained land. This work evaluated the environmental impacts of alternative agricultural uses for poorly drained farm land in Ireland using life cycle assessment (LCA). The avoided burden of the displaced product was used to calculate the net environmental consequences in the context of regional or global markets. The impact categories evaluated were climate change, eutrophication and acidification, all expressed per hectare of land for the alternative land uses, which were pasture-based milk, suckler beef and lowland sheep production and coniferous forestry. Beef had the lowest net climate change impact with global marginal and average product substitution while sheep had the lowest net climate change impact with European displaced product. For net eutrophication and acidification, dairy had the lowest impacts with European and global average displaced product. With global marginal displaced product, forestry had the lowest net eutrophication impact and sheep had the lowest net acidification impact. From an Irish perspective, forestry would generate the lowest environmental impacts and would also increase soil carbon stock, but this was not the best land use option from global perspective. Overall it can be concluded that a pasture based dairy or sheep system would have the greatest net global impact reduction (i.e. greatest global benefit) as land use options for farms with poorly drained soils. Prioritizing climate change, suckler beef system would perhaps be more favourable. It is clear that the choice of the displaced regional or global co-product from the market has a great influence on the results and there is a need to consider more detailed consumption modelling to better understand the substitution process. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Spatial variation in herbicide leaching from a marine clay soil via subsurface drains

    Science.gov (United States)

    Ulén, Barbro M; Larsbo, Mats; Kreuger, Jenny K; Svanbäck, Annika

    2013-01-01

    Background Subsurface transport via tile drains can significantly contribute to pesticide contamination of surface waters. The spatial variation in subsurface leaching of normally applied herbicides was examined together with phosphorus losses in 24 experimental plots with water sampled flow-proportionally. The study site was a flat, tile-drained area with 60% marine clay in the topsoil in southeast Sweden. The objectives were to quantify the leaching of frequently used herbicides from a tile drained cracking clay soil and to evaluate the variation in leaching within the experimental area and relate this to topsoil management practices (tillage method and structure liming). Results In summer 2009, 0.14, 0.22 and 1.62%, respectively, of simultaneously applied amounts of MCPA, fluroxypyr and clopyralid were leached by heavy rain five days after spraying. In summer 2011, on average 0.70% of applied bentazone was leached by short bursts of intensive rain 12 days after application. Peak flow concentrations for 50% of the treated area for MCPA and 33% for bentazone exceeded the Swedish no-effect guideline values for aquatic ecosystems. Approximately 0.08% of the glyphosate applied was leached in dissolved form in the winters of 2008/2009 and 2010/2011. Based on measurements of glyphosate in particulate form, total glyphosate losses were twice as high (0.16%) in the second winter. The spatial inter-plot variation was large (72–115%) for all five herbicides studied, despite small variations (25%) in water discharge. Conclusions The study shows the importance of local scale soil transport properties for herbicide leaching in cracking clay soils. © 2013 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry. PMID:23658148

  9. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft.

    Science.gov (United States)

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-25

    Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB) using left internal thoracic artery (LITA). Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position); II (n = 33 intact pleural cavity). Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD) 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5. In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups. Subxyphoid insertion of pleural drain provides similar effects to

  10. A randomized trial of early versus delayed mediastinal drain removal after cardiac surgery using silastic and conventional tubes

    Science.gov (United States)

    Moss, Emmanuel; Miller, Corey S.; Jensen, Henrik; Basmadjian, Arsène; Bouchard, Denis; Carrier, Michel; Perrault, Louis P.; Cartier, Raymond; Pellerin, Michel; Demers, Philippe

    2013-01-01

    OBJECTIVES Mediastinal drainage following cardiac surgery with traditional large-bore plastic tubes can be painful and cumbersome. This study was designed to determine whether prolonged drainage (5 days) with a silastic tube decreased the incidence of significant pericardial effusion and tamponade following aortic or valvular surgery. METHODS One hundred and fifty patients undergoing valvular or aortic surgery in a tertiary cardiac surgery institution were randomized to receive a conventional mediastinal tube plus a silastic Blake drain (n = 75), or two conventional tubes (n = 75). Conventional drains were removed on postoperative day (POD) 1, while Blake drains were removed on POD 5. The primary end-point was the combined incidence of significant pericardial effusion (≥15 mm) or tamponade through POD 5. Secondary end-points included total mediastinal drainage, postoperative atrial fibrillation (AF) and pain. RESULTS Analysis was performed for 67 patients in the Blake group and 73 in the conventional group. There was no difference between the two groups in the combined end-point of significant effusion or tamponade (7.4 vs 8.3%, P = 0.74), or in the incidence of AF (47 vs 46%, P = 0.89). Mean 24-h drainage was greater in the Blake group than in the conventional group (749 ± 444 ml vs 645 ± 618 ml, P tubes is safe and does not increase postoperative pain. There was no difference between the Blake and conventional drains with regard to significant pericardial effusion or tamponade in this cohort; however, this conclusion is limited by the low overall incidence of the primary outcome in this cohort. PMID:23575759

  11. Effects of drain-wall in mitigating N-hit single event transient via 45 nm CMOS process

    International Nuclear Information System (INIS)

    Xu, X Y; Tang, M H; Xiao, Y G; Yan, S A; Zhang, W L; Li, Z; Xiong, Y; Zhao, W; Guo, H X

    2015-01-01

    A three-dimensional (3D) technology computer-aided design (TCAD) simulation in a novel layout technique for N-hit single event transient (SET) mitigation based on drain-wall layout technique is proposed. Numerical simulations of both single-device and mixed-mode show that the proposed layout technique designed with 45 nm CMOS process can efficiently reduce not only charge collection but also SET pulse widths (W SET ). What is more, simulations show that impacts caused by part of ion-incidents can be shielded with this novel layout technique. When compared with conventional layout technique and guard drain layout technique, we find that the proposed novel layout technique can provide the best benefit of SET mitigation with a small sacrifice in effective area. (paper)

  12. Ubuntunet Alliance: A Collaborative Research Platform for Sharing of Technological Tools for Eradication of Brain Drain

    Directory of Open Access Journals (Sweden)

    Jameson Mbale

    2012-12-01

    Full Text Available The UbuntuNet Alliance Alliance is well-placed to facilitate interaction between education and research institutions and the African academic and researcher in the Diaspora so that together they can strengthen research that will exploit new technological tools and increase the industrial base. It is envisaged that the Alliance will become an important vehicle for linkages that will facilitate repatriation of scientific knowledge and skills to Africa and even help reduce and eventually eradicate the brain drain which has taken so many excellent intellectuals to the developed world. As organisational vehicles for inter-institutional collaboration both established and emerging NRENs can play a critical role in reversing these trends and in mitigating what appears to be the negative impact of the brain drain.

  13. Minimizing the Moisture Damage and Drain down of Iraqi SMA Mixtures Using Waste Additives

    Directory of Open Access Journals (Sweden)

    Ali Al-Hadidy

    2013-04-01

    Full Text Available This research deals with the viability of using polyester fiber (PF, crumb rubber tire (CRT and cellulose fiber (CF as stabilizing waste additives in producing Iraqi SMA mixtures that sustain drain down phenomenon and moisture damage sensitivity. Different ratios of these additives (0.1, 0.2, and 0.3% by weight of aggregate and filler were mixed with 40/50 paving asphalt by means of dry process. Unmodified and modified SMA mixtures were subjected to drain down, Marshall, static indirect tensile strength, tensile stiffness modulus, static compressive strength, tensile strength ratio and index of retained strength tests. A set of regression equations between these tests were established. In addition, an optimization table based on these tests, which can be used to select the type or amount of additive for any field applications has been determined and reported. The results indicated that the inclusion of these additives in SMA mixtures can satisfy the performance requirement of high temperature and much rain zone.

  14. Cellular dynamics in the draining lymph nodes during sensitization and elicitation phases of contact hypersensitivity

    DEFF Research Database (Denmark)

    Larsen, Jeppe Madura; Geisler, Carsten; Nielsen, Martin Weiss

    2007-01-01

    BACKGROUND: The different role of various immunological effector cells in contact hypersensitivity (CHS) is receiving increased attention. During the past decade, the involvement of different cell types in CHS has been investigated by the use of antibody-induced depletion of specific subtypes...... of immunological cells and by studying knockout mice lacking one or more of these immunological cell populations. OBJECTIVES: To develop a method for studying the collective cellular dynamics of immune cells in the draining lymph nodes during CHS in intact animals. PATIENTS/METHODS: Mice were sensitized and....../or challenged with 2,4-dinitrofluorobenzene or oxazolone. Using multi-parameter flow cytometry we determined the proliferation, activation state, and absolute number of helper T cells, cytotoxic T cells, B cells, and natural killer cells in the draining lymph nodes. RESULTS: The presented method can be applied...

  15. High soil solution carbon and nitrogen concentrations in a drained Atlantic bog are reduced to natural levels by 10 years of rewetting

    Science.gov (United States)

    Frank, S.; Tiemeyer, B.; Gelbrecht, J.; Freibauer, A.

    2014-04-01

    Anthropogenic drainage of peatlands releases additional greenhouse gases to the atmosphere, and dissolved carbon (C) and nutrients to downstream ecosystems. Rewetting drained peatlands offers a possibility to reduce nitrogen (N) and C losses. In this study, we investigate the impact of drainage and rewetting on the cycling of dissolved C and N as well as on dissolved gases, over a period of 1 year and a period of 4 months. We chose four sites within one Atlantic bog complex: a near-natural site, two drained grasslands with different mean groundwater levels and a former peat cutting area rewetted 10 years ago. Our results clearly indicate that long-term drainage has increased the concentrations of dissolved organic carbon (DOC), ammonium, nitrate and dissolved organic nitrogen (DON) compared to the near-natural site. DON and ammonium contributed the most to the total dissolved nitrogen. Nitrate concentrations below the mean groundwater table were negligible. The concentrations of DOC and N species increased with drainage depth. In the deeply-drained grassland, with a mean annual water table of 45 cm below surface, DOC concentrations were twice as high as in the partially rewetted grassland with a mean annual water table of 28 cm below surface. The deeply drained grassland had some of the highest-ever observed DOC concentrations of 195.8 ± 77.3 mg L-1 with maximum values of >400 mg L-1. In general, dissolved organic matter (DOM) at the drained sites was enriched in aromatic moieties and showed a higher degradation status (lower DOC to DON ratio) compared to the near-natural site. At the drained sites, the C to N ratios of the uppermost peat layer were the same as of DOM in the peat profile. This suggests that the uppermost degraded peat layer is the main source of DOM. Nearly constant DOM quality through the profile furthermore indicated that DOM moving downwards through the drained sites remained largely biogeochemically unchanged. Unlike DOM concentration, DOM

  16. Personal Networks and Migration Decision: The Case of Jamaican Brain Drain

    Directory of Open Access Journals (Sweden)

    Rosalyn NEGRÓN

    2012-05-01

    Full Text Available Brain drain is the phenomena where the most educated citizens of a country migrate to countries with better opportunities. This typically affects developing countries more negatively than developed countries. Given the close proximity to the US and the high standard of education of its citizens, Jamaica tends to be particularly hard hit by this brain drain. In this paper I examine intentions to migrate among skilled and educated Jamaicans. Specifically, I explore to what extent the composition of their personal network affects their decision to migrate. The data set consists of 62 university students, roughly half of who intended to migrate. Data were collected on 40 people that they knew, including information about social support provided by their social networks. The socioeconomic data about respondents did not predict intentions to migrate. However, students at Campion College, a prestigious high school linked to upper middle class status, were significantly more likely to express an interest in migration than students from other schools. Frequency of travel abroad was negatively related to intention to migrate for those that had traveled at least once. The proportion of network members that provided informational and career advice was significantly higher for those that intended to migrate. Implications of these findings for immigration policy in Jamaica and receiving countries are discussed.

  17. Plumbing the brain drain.

    Science.gov (United States)

    Saravia, Nancy Gore; Miranda, Juan Francisco

    2004-08-01

    Opportunity is the driving force of migration. Unsatisfied demands for higher education and skills, which have been created by the knowledge-based global economy, have generated unprecedented opportunities in knowledge-intensive service industries. These multi-trillion dollar industries include information, communication, finance, business, education and health. The leading industrialized nations are also the focal points of knowledge-intensive service industries and as such constitute centres of research and development activity that proactively draw in talented individuals worldwide through selective immigration policies, employment opportunities and targeted recruitment. Higher education is another major conduit of talent from less-developed countries to the centres of the knowledge-based global economy. Together career and educational opportunities drive "brain drain and recirculation". The departure of a large proportion of the most competent and innovative individuals from developing nations slows the achievement of the critical mass needed to generate the enabling context in which knowledge creation occurs. To favourably modify the asymmetric movement and distribution of global talent, developing countries must implement bold and creative strategies that are backed by national policies to: provide world-class educational opportunities, construct knowledge-based research and development industries, and sustainably finance the required investment for these strategies. Brazil, China and India have moved in this direction, offering world-class education in areas crucial to national development, such as biotechnology and information technology, paralleled by investments in research and development. As a result, only a small proportion of the most highly educated individuals migrate from these countries, and research and development opportunities employ national talent and even attract immigrants.

  18. Reduce chest pain using modified silicone fluted drain tube for chest drainage after video-assisted thoracic surgery (VATS) lung resection.

    Science.gov (United States)

    Li, Xin; Hu, Bin; Miao, Jinbai; Li, Hui

    2016-02-01

    The aim of this study was to assess the feasibility, efficacy and safety of a modified silicone fluted drain tube after video-assisted thoracic surgery (VATS) lung resection. The prospective randomized study included 50 patients who underwent VATS lung resection between March 2015 and June 2015. Eligible patients were randomized into two groups: experimental group (using the silicone fluted drain tubes for chest drainage) and control group (using standard drain tubes for chest drainage). The volume and characteristics of drainage, postoperative (PO) pain scores and hospital stay were recorded. All patients received standard care during hospital admission. In accordance with the exit criteria, three patients were excluded from study. The remaining 47 patients included in the final analysis were divided into two groups: experiment group (N=24) and control group (N=23). There was no significant difference between the two groups in terms of age, sex, height, weight, clinical diagnosis and type of surgical procedure. There was a trend toward less PO pain in experimental group on postoperative day (POD) 1, with a statistically significant difference. Patients in experimental group had a reduced occurrence of fever [temperature (T) >37.4 °C] compared to the control group. The silicone fluted drain tube is feasible and safe and may relieve patient PO pain and reduce occurrence of fever without the added risk of PO complications.

  19. Effect of defect creation and migration on hump characteristics of a-InGaZnO thin film transistors under long-term drain bias stress with light illumination

    Science.gov (United States)

    Cho, Yong-Jung; Kim, Woo-Sic; Lee, Yeol-Hyeong; Park, Jeong Ki; Kim, Geon Tae; Kim, Ohyun

    2018-06-01

    We investigated the mechanism of formation of the hump that occurs in the current-voltage I-V characteristics of amorphous InGaZnO (a-IGZO) thin film transistors (TFTs) that are exposed to long-term drain bias stress under illumination. Transfer characteristics showed two-stage degradation under the stress. At the beginning of the stress, the I-V characteristics shifted in the negative direction with a degradation of subthreshold slope, but the hump phenomenon developed over time in the I-V characteristics. The development of the hump was related to creation of defects, especially ionized oxygen vacancies which act as shallow donor-like states near the conduction-band minimum in a-IGZO. To further investigate the hump phenomenon we measured a capacitance-voltage C-V curve and performed two-dimensional device simulation. Stretched-out C-V for the gate-to-drain capacitance and simulated electric field distribution which exhibited large electric field near the drain side of TFT indicated that VO2+ were generated near the drain side of TFT, but the hump was not induced when VO2+ only existed near the drain side. Therefore, the degradation behavior under DBITS occurred because VO2+ were created near the drain side, then were migrated to the source side of the TFT.

  20. A study of technetium-labelled sulphide colloid uptake by regional lymph nodes draining a tumour-bearing area

    International Nuclear Information System (INIS)

    Boak, J.L.; Agwunobi, T.C.

    1978-01-01

    With appropriate controls, experimental groups of inbred C 3 H mice bearing a syngeneic mammary carcinoma challenge in their right rear footpads were injected in both rear footpads with 99 Tcsup(m)ASC. Mice were sacrificed 15 and 90 min after the labelled colloid injection. Popliteal and sacral lymph nodes were weighed and counted in a well scintillation counter. A marked inhibition of labelled colloid uptake was demonstrated in regional lymph nodes draining a tumour-bearing area. Rabbits bearing VX 2 carcinoma in a forelimb received 99 Tc sup(m)ASC into each front footpad. Depression of labelled colloid uptake by regional lymph nodes draining tumour was evident on gamma-camera scanning. (author)

  1. Denial of student visas leads to brain drain from university research

    CERN Multimedia

    Wertheimer, L K

    2002-01-01

    America's move to shut the gate on student visas after the terrorist attack on the Twin Towers, has created a brain drain for universities that rely on top foreign students to help with scientific research. Professors, graduate school deans and officials from national science societies say hundreds of foreign students recruited to work on projects in such areas as physics, math and petroleum engineering they couldn't get visas this fall. Some gave up and went to other countries instead (2 pages).

  2. Brain drain: a challenge to global mental health.

    Science.gov (United States)

    Oladeji, Bibilola D; Gureje, Oye

    2016-08-01

    The brain drain of medical professionals from lower-income to higher-income countries contributes to the current inequity that characterises access to mental healthcare by those in need across the world and hinders efforts to scale up mental health services in resource-constrained settings, especially in Nigeria and other West African countries. The migration of skilled workers is driven by a combination of the globalisation of the labour market and the ability of highly resourced countries to attract and retain specialists from poorer countries. If we are to ameliorate the worldwide shortage of mental health professionals, we need to find innovative ways of attracting young doctors into psychiatric training in all countries. We must also introduce measures to improve health worker retention in low- and middle-income countries.

  3. Molybdenum, vanadium, and uranium weathering in small mountainous rivers and rivers draining high-standing islands

    Science.gov (United States)

    Gardner, Christopher B.; Carey, Anne E.; Lyons, W. Berry; Goldsmith, Steven T.; McAdams, Brandon C.; Trierweiler, Annette M.

    2017-12-01

    Rivers draining high standing islands (HSIs) and small mountainous rivers (SMRs) are known to have extremely high sediment fluxes, and can also have high chemical weathering yields, which makes them potentially important contributors to the global riverine elemental flux to the ocean. This work reports on the riverine concentrations, ocean flux, and weathering yields of Molybdenum (Mo), Vanadium (V), and Uranium (U) in a large number of small but geochemically important rivers using 338 river samples from ten lithologically-diverse regions. These redox-sensitive elements are used extensively to infer paleo-redox conditions in the ocean, and Mo and V are also important rock-derived micronutrients used by microorganisms in nitrogen fixation. Unlike in large river systems, in which dissolved Mo has been attributed predominately to pyrite dissolution, Mo concentrations in these rivers did not correlate with sulfate concentrations. V was found to correlate strongly with Si in terrains dominated by silicate rocks, but this trend was not observed in primarily sedimentary regions. Many rivers exhibited much higher V/Si ratios than larger rivers, and rivers draining young Quaternary volcanic rocks in Nicaragua had much higher dissolved V concentrations (mean = 1306 nM) than previously-studied rivers. U concentrations were generally well below the global average with the exception of rivers draining primarily sedimentary lithologies containing carbonates and shales. Fluxes of U and Mo from igneous terrains of intermediate composition are lower than the global average, while fluxes of V from these regions are higher, and up to two orders of magnitude higher in the Nicaragua rivers. Weathering yields of Mo and V in most regions are above the global mean, despite lower than average concentrations measured in some of those systems, indicating that the chemical weathering of these elements are higher in these SMR watersheds than larger drainages. In regions of active boundaries

  4. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    OpenAIRE

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-01

    Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary f...

  5. Direct imprinting of indium-tin-oxide precursor gel and simultaneous formation of channel and source/drain in thin-film transistor

    Science.gov (United States)

    Haga, Ken-ichi; Kamiya, Yuusuke; Tokumitsu, Eisuke

    2018-02-01

    We report on a new fabrication process for thin-film transistors (TFTs) with a new structure and a new operation principle. In this process, both the channel and electrode (source/drain) are formed simultaneously, using the same oxide material, using a single nano-rheology printing (n-RP) process, without any conventional lithography process. N-RP is a direct thermal imprint technique and deforms oxide precursor gel. To reduce the source/drain resistance, the material common to the channel and electrode is conductive indium-tin-oxide (ITO). The gate insulator is made of a ferroelectric material, whose high charge density can deplete the channel of the thin ITO film, which realizes the proposed operation principle. First, we have examined the n-RP conditions required for the channel and source/drain patterning, and found that the patterning properties are strongly affected by the cooling rate before separating the mold. Second, we have fabricated the TFTs as proposed and confirmed their TFT operation.

  6. Contribution of Nutrients and some Trace Metals from a Huge Egyptian Drain to the SE-Mediterranean Sea, west of Alexandria

    Directory of Open Access Journals (Sweden)

    O.A. EL-RAYIS

    2006-06-01

    The present work is a monthly study over a year of levels of concentration of some mainly trace elements (nutrients and some heavy metals in the proper water of the drain before mixing and in the effl uent from the lake, and calculations of both the concentrations and the corresponding expected loads of these elements contributed by the drain to the sea. The results revealed that the respective loads to the sea are 77380 ton/year for total suspended matter, 823 tons/year for dissolved PO4 -P, 4745 tons/year for inorganic N, 23.7 tons/year for Fe, 3.28 tons/year for Mn, 5.84 tons/year for Cu, 2.9 ton/year for Cd, and 24 tons/year for Zn. The elements loaded by the lake effl uent represent values ranging between 8 and 57.5% of the total load contributed by the drain to the sea. The plant nutrients (ammonia and reactive phosphorus are of values exceeding 44%.

  7. Preventing ventriculostomy-related infections with antibiotic-impregnated drains in hospitals : a two-centre Dutch study

    NARCIS (Netherlands)

    Verberk, J. D M; Berkelbach vd Sprenkel, J. W; Arts, M. P.; Dennesen, P. J W; Bonten, M. J M; van Mourik, M. S M

    2016-01-01

    This observational cohort study assessed the effect of the introduction of antibiotic-impregnated external ventricular drains (AI-EVDs), as opposed to plain silicone EVDs, on the occurrence of ventriculostomy-related infections (VRIs) in two Dutch hospitals, with no other changes to their clinical

  8. Consequences assessment for fuel channel failure with consequential moderator drain

    International Nuclear Information System (INIS)

    Wahba, N.N.; Bayoumi, M.H.

    2002-01-01

    This paper documents the consequences of spontaneous pressure tube/consequential calandria tube rupture followed by the ejection of end fittings (as a result of guillotine failure of pressure tube) leading to the drain of the moderator. The event is postulated to occur in conjunction with an independent failure of Emergency Coolant Injection System (ECIS). The results of the detailed consequence assessments are used to propose a course of action to mitigate the consequences of such an event. A methodology based on a lumped-parameter model was developed to assess the consequences of the postulated event. (author)

  9. The underwater installation of a drained geomembrane system on Lost Creek Dam

    International Nuclear Information System (INIS)

    Onken, S.; Harlan, R.C.; Wilkes, J.; Vaschetti, G.

    1998-01-01

    Lost Creek Dam was constructed in California around 1923. It is a 122 foot high concrete arch dam with a crest elevation of 3,287 feet and a crest length of 490 feet. Over the years, the dam and the condition of the concrete face have deteriorated. The concrete is porous and seeps water along the entire downstream face. In winter, the seeping water freezes, penetrates the concrete and causes expansion and spalling of the concrete surface. In some places, the concrete has very low strength to a depth of a foot or more, rendering the dam only marginally safe. Seven mitigative measures were identified as possible solutions to the problem. It was determined that the seepage of the water through the concrete dam could be stopped with the installation of a geomembrane to the upstream face. This paper describes the unique underwater installation of a drained geomembrane system on the concrete face of the dam. This was the first ever installation of a drained geomembrane system on an entire dam using divers. Monitoring will determine the success of the project, and whether the seepage of the water through the porous concrete had been reduced sufficiently to stop the deterioration of the concrete on the downstream face. 2 refs., 12 figs

  10. Localized Glacier Deformation Associated with Filling and Draining of a Glacier-Dammed Lake and Implications for Outburst Flood Hydraulics

    Science.gov (United States)

    Cunico, M. L.; Walder, J. S.; Fountain, A. G.; Trabant, D. C.

    2001-12-01

    During the summer of 2000, we measured displacements of 22 survey targets on the surface of Kennicott Glacier, Alaska, in the vicinity of Hidden Creek Lake, an ice-dammed lake in a tributary valley that fills and drains annually. Targets were distributed over a domain about equal in width to the lake, from near the glacier/lake margin to a distance of about 1 km from the margin. Targets were surveyed over a 24-day period as the lake filled and then drained. Lake stage was independently monitored. Vertical movement of targets generally fell off with distance d from the lake. As the lake filled, targets with d typically about 0.5 m/d--with a few targets rising slightly faster than the lake. The rate of vertical movement fell off rapidly with distance from the lake: for d = ca. 600 m--roughly twice the local ice thickness--targets moved upward only about 10% as fast as lake stage. Vertical movement of targets with d > ca. 1 km seemed to be uncorrelated with lake stage. The general pattern is consistent with the idea that a wedge of water extended beneath the glacier to a distance of perhaps 300 to 400 m from the visible margin of the lake and exerts buoyant stresses on the ice that were transmitted into the main body of the glacier and caused flexure. This scenario bears some resemblance to tidal deflections of ice shelves or tidewater glaciers. For a given value of lake stage, target elevations were invariably higher as the lake drained than as the lake filled. Moreover, survey targets at a distance of about 400 m or more from the lake continued to rise for some time even after the lake began to drain. The lag time between the beginning of lake drainage and the beginning of target downdrop increased with distance from the lake, with the lag being about 14 hours at a distance of 400 m from the lake. (The lake drained completely in approximately 75 hours.) The likeliest explanations for the departure from reversibility and the existence of the time lag are either (i) a

  11. A novel source–drain follower for monolithic active pixel sensors

    Energy Technology Data Exchange (ETDEWEB)

    Gao, C., E-mail: chaosong.gao@mails.ccnu.edu.cn [Central China Normal University, Wuhan (China); Aglieri, G.; Hillemanns, H. [CERN, Geneva (Switzerland); Huang, G., E-mail: gmhuang@phy.ccnu.edu.cn [Central China Normal University, Wuhan (China); Junique, A.; Keil, M. [CERN, Geneva (Switzerland); Kim, D. [Dongguk University, Seoul (Korea, Republic of); Yonsei University, Seoul (Korea, Republic of); Kofarago, M.; Kugathasan, T.; Mager, M.; Marin Tobon, C.A.; Martinengo, P. [CERN, Geneva (Switzerland); Mugnier, H. [Mind, Archamps (France); Musa, L. [CERN, Geneva (Switzerland); Lee, S. [Dongguk University, Seoul (Korea, Republic of); Yonsei University, Seoul (Korea, Republic of); Reidt, F. [CERN, Geneva (Switzerland); Ruprecht-Karls-Universitat Heidelberg, Heidelberg (Germany); Riedler, P. [CERN, Geneva (Switzerland); Rousset, J. [Mind, Archamps (France); Sielewicz, K.M. [CERN, Geneva (Switzerland); Warsaw University of Technology, Warsaw (Poland); Snoeys, W. [CERN, Geneva (Switzerland); and others

    2016-09-21

    Monolithic active pixel sensors (MAPS) receive interest in tracking applications in high energy physics as they integrate sensor and readout electronics in one silicon die with potential for lower material budget and cost, and better performance. Source followers (SFs) are widely used for MAPS readout: they increase charge conversion gain 1/C{sub eff} or decrease the effective sensing node capacitance C{sub eff} because the follower action compensates part of the input capacitance. Charge conversion gain is critical for analog power consumption and therefore for material budget in tracking applications, and also has direct system impact. This paper presents a novel source–drain follower (SDF), where both source and drain follow the gate potential improving charge conversion gain. For the inner tracking system (ITS) upgrade of the ALICE experiment at CERN, low material budget is a primary requirement. The SDF circuit was studied as part of the effort to optimize the effective capacitance of the sensing node. The collection electrode, input transistor and routing metal all contribute to C{sub eff}. Reverse sensor bias reduces the collection electrode capacitance. The novel SDF circuit eliminates the contribution of the input transistor to C{sub eff}, reduces the routing contribution if additional shielding is introduced, provides a way to estimate the capacitance of the sensor itself, and has a voltage gain closer to unity than the standard SF. The SDF circuit has a somewhat larger area with a somewhat smaller bandwidth, but this is acceptable in most cases. A test chip, manufactured in a 180 nm CMOS image sensor process, implements small prototype pixel matrices in different flavors to compare the standard SF to the novel SF and to the novel SF with additional shielding. The effective sensing node capacitance was measured using a {sup 55}Fe source. Increasing reverse substrate bias from −1 V to −6 V reduces C{sub eff} by 38% and the equivalent noise charge

  12. A novel source–drain follower for monolithic active pixel sensors

    International Nuclear Information System (INIS)

    Gao, C.; Aglieri, G.; Hillemanns, H.; Huang, G.; Junique, A.; Keil, M.; Kim, D.; Kofarago, M.; Kugathasan, T.; Mager, M.; Marin Tobon, C.A.; Martinengo, P.; Mugnier, H.; Musa, L.; Lee, S.; Reidt, F.; Riedler, P.; Rousset, J.; Sielewicz, K.M.; Snoeys, W.

    2016-01-01

    Monolithic active pixel sensors (MAPS) receive interest in tracking applications in high energy physics as they integrate sensor and readout electronics in one silicon die with potential for lower material budget and cost, and better performance. Source followers (SFs) are widely used for MAPS readout: they increase charge conversion gain 1/C_e_f_f or decrease the effective sensing node capacitance C_e_f_f because the follower action compensates part of the input capacitance. Charge conversion gain is critical for analog power consumption and therefore for material budget in tracking applications, and also has direct system impact. This paper presents a novel source–drain follower (SDF), where both source and drain follow the gate potential improving charge conversion gain. For the inner tracking system (ITS) upgrade of the ALICE experiment at CERN, low material budget is a primary requirement. The SDF circuit was studied as part of the effort to optimize the effective capacitance of the sensing node. The collection electrode, input transistor and routing metal all contribute to C_e_f_f. Reverse sensor bias reduces the collection electrode capacitance. The novel SDF circuit eliminates the contribution of the input transistor to C_e_f_f, reduces the routing contribution if additional shielding is introduced, provides a way to estimate the capacitance of the sensor itself, and has a voltage gain closer to unity than the standard SF. The SDF circuit has a somewhat larger area with a somewhat smaller bandwidth, but this is acceptable in most cases. A test chip, manufactured in a 180 nm CMOS image sensor process, implements small prototype pixel matrices in different flavors to compare the standard SF to the novel SF and to the novel SF with additional shielding. The effective sensing node capacitance was measured using a "5"5Fe source. Increasing reverse substrate bias from −1 V to −6 V reduces C_e_f_f by 38% and the equivalent noise charge (ENC) by 22% for the

  13. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    Guizilini Solange

    2012-01-01

    Full Text Available Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG. Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB using left internal thoracic artery (LITA. Methods Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position; II (n = 33 intact pleural cavity. Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5. Results In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups. Conclusion Subxyphoid

  14. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  15. Reducing resin use in floor drain processing system

    International Nuclear Information System (INIS)

    Flint, W.; Hobart, S.A.; Miller, A.D.

    1995-01-01

    The Kewaunee Nuclear Power Plant utilizes two mixed bed demineralizers for processing floor drain wastes. These demineralizers were originally designed for stream generator blowdown treatment, but were not needed for that purpose. Effluent from the resin beds is monitored for radioactivity and released for discharge. Plant radwaste inleakage volumes and resin disposal volumes were low in comparison with industry averages, but decontamination factors through the treatment system were less than desirable. Release criteria for discharges always had been met, but plant personnel wished to decrease their already low discharges of radioactive species, reduce their resin disposal costs, and provide a margin of safety in the unlikely event that fuel damage would be experienced during an operating cycle. This paper describes the study initiated to address those issues, the findings of the study, and results of implementing some of the study recommendations

  16. Centrifuge modelling of drained lateral pile - soil response

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte

    of rigid piles. The tests have been performed in homogeneously dense dry or saturated Fontainebleau sand in order to mimic simplified drained offshore soil conditions. Approximately half of the tests have been carried out to investigate the centrifuge procedure in order to create a methodology of testing...... tests were used to investigate the pile - soil interaction to gain a better in-sight into the complex problem. A monotonic test series was carried out initially and then pile - soil interaction curves were deduced from these tests and compared with methodologies used today. The results indicate...... that the current methodologies can be improved and a modification to the methodology has been proposed. Secondly, a cyclic test series was carried out. The accumulation of displacement and the change in secant stiffness of the total response of these tests were evaluated. A simple mathematical model was proposed...

  17. A pleural vacuum relief device for pleural drain unit use in the hyperbaric environment.

    Science.gov (United States)

    Gelsomino, Marco; Tsouras, Theo; Millar, Ian; Fock, Andrew

    2017-09-01

    When a standard water-seal pleural drain unit (PDU) is used under hyperbaric conditions there are scenarios where excessive negative intrapleural pressure (IPP) and/or fluid reflux can be induced, risking significant morbidity. We developed and tested a pleural vacuum relief (PVR) device which automatically manages these risks, whilst allowing more rapid hyperbaric pressure change rates. The custom-made PVR device consists of a one-way pressure relief valve connected in line with a sterile micro filter selected for its specific flow capacity. The PVR device is designed for connection to the patient side sampling port of a PDU system, allowing inflow of ambient air whenever negative pressure is present, creating a small, controlled air leak which prevents excessive negative pressure. The hyperbaric performance of a Pleur-Evac A-6000 intercostal drain was assessed with and without this added device by measuring simulated IPP with an electronic pressure monitor connected at the patient end of the PDU. IPP readings were taken at 10, 15, 20 and 30 cmH₂O of suction (set on the drain unit) at compression rates of 10, 30, 60, 80, 90 and 180 kPa·min⁻¹ to a pressure of 280 kPa. At any compression rate of > 10 kPa·min⁻¹, the negative IPP generated by the Pleur-Evac A-6000 alone was excessive and resulted in back flow through the PDU water seal. By adding the PVR device, the generated negative IPP remains within a clinically acceptable range, allowing compression rates of at least 30 kPa·min⁻¹ with suction settings up to -20 cmH₂O during all phases of hyperbaric treatment. The PDU PVR device we have developed works well, minimising attendant workload and automatically avoiding the excessive negative IPPs that can otherwise occur. This device should only be used with suction.

  18. Experiments of draining and filling processes in a collapsible tube at high external pressure

    Science.gov (United States)

    Flaud, P.; Guesdon, P.; Fullana, J.-M.

    2012-02-01

    The venous circulation in the lower limb is mainly controlled by the muscular action of the calf. To study the mechanisms governing the venous draining and filling process in such a situation, an experimental setup, composed by a collapsible tube under external pressure, has been built. A valve preventing back flows is inserted at the bottom of the tube and allows to model two different configurations: physiological when the fluid flow is uni-directional and pathological when the fluid flows in both directions. Pressure and flow rate measurements are carried out at the inlet and outlet of the tube and an original optical device with three cameras is proposed to measure the instantaneous cross-sectional area. The experimental results (draining and filling with physiological or pathological valves) are confronted to a simple one-dimensional numerical model which completes the physical interpretation. One major observation is that the muscular contraction induces a fast emptying phase followed by a slow one controlled by viscous effects, and that a defect of the valve decreases, as expected, the ejected volume.

  19. [To what extent is Mexican emigration to the United States a brain drain?].

    Science.gov (United States)

    Osborn, T N; Newton, J R

    1979-01-01

    The authors examine the problem of legal Mexican emigration to the United States, analyzing its effects on both countries. Characteristics of the Mexican emigrants are examined with respect to level of employment, salary, and employment opportunities. The total number of emigrants in professional and technical capacities is investigated in order to determine the likelihood of a brain drain from Mexico to the United States

  20. Improving band-to-band tunneling in a tunneling carbon nanotube field effect transistor by multi-level development of impurities in the drain region

    Science.gov (United States)

    Naderi, Ali; Ghodrati, Maryam

    2017-12-01

    In this paper, in order to improve the performance of a tunneling carbon nanotube field effect transistor (T-CNTFET) a new structure is proposed using multi-level impurity distribution along the drain region. The new T-CNTFET structure consists of six parts in the drain with stepwise doping distribution. The impurities on the drain side are n -type and the length of each region is 5nm. Electronic features of the proposed structure are simulated by the solution of Poisson and Schrödinger equations and the self-consistent method using Non-equilibrium Green's Function (NEGF). Simulation results show that the proposed structure reduces the band curvature near the drain-channel connection and widens the tunneling barrier. As a result, band-to-band tunneling and the OFF current are reduced and the ON/OFF current ratio increases in comparison with the conventional structure. In summary, by improving the subthreshold swing parameters, delay time, power delay product ( PDP and cut-off frequency compared to the conventional structure, the proposed structure can be considered as a proper candidate for digital applications with high speed and low power dissipation.

  1. Large CO2 and CH4 release from a flooded formerly drained fen

    Science.gov (United States)

    Sachs, T.; Franz, D.; Koebsch, F.; Larmanou, E.; Augustin, J.

    2016-12-01

    Drained peatlands are usually strong carbon dioxide (CO2) sources. In Germany, up to 4.5 % of the national CO2 emissions are estimated to be released from agriculturally used peatlands and for some peatland-rich northern states, such as Mecklenburg-Western Pomerania, this share increases to about 20%. Reducing this CO2 source and restoring the peatlands' natural carbon sink is one objective of large-scale nature protection and restoration measures, in which 37.000 ha of drained and degraded peatlands in Mecklenburg-Western Pomerania are slated for rewetting. It is well known, however, that in the initial phase of rewetting, a reduction of the CO2 source strength is usually accompanied by an increase in CH4 emissions. Thus, whether and when the intended effects of rewetting with regard to greenhouse gases are achieved, depends on the balance of CO2 and CH4 fluxes and on the duration of the initial CH4 emission phase. In 2013, a new Fluxnet site went online at a flooded formerly drained river valley fen site near Zarnekow, NE Germany (DE-Zrk), to investigate the combined CO2 and CH4 dynamics at such a heavily degraded and rewetted peatland. The site is dominated by open water with submerged and floating vegetation and surrounding Typha latifolia.Nine year after rewetting, we found large CH4 emissions of 53 g CH4 m-2 a-1 from the open water area, which are 4-fold higher than from the surrounding vegetation zone (13 g CH4 m-2 a-1). Surprisingly, both the open water and the vegetated area were net CO2 sources of 158 and 750 g CO2 m-2 a-1, respectively. Unusual meteorological conditions with a warm and dry summer and a mild winter might have facilitated high respiration rates, particularly from temporally non-inundated organic mud in the vegetation zone.

  2. Drained coastal peatlands: A potential nitrogen source to marine ecosystems under prolonged drought and heavy storm events-A microcosm experiment.

    Science.gov (United States)

    Wang, Hongjun; Richardson, Curtis J; Ho, Mengchi; Flanagan, Neal

    2016-10-01

    Over the past several decades there has been a massive increase in coastal eutrophication, which is often caused by increased runoff input of nitrogen from landscape alterations. Peatlands, covering 3% of land area, have stored about 12-21% of global soil organic nitrogen (12-20Pg N) around rivers, lakes and coasts over millennia and are now often drained and farmed. Their huge nitrogen pools may be released by intensified climate driven hydrologic events-prolonged droughts followed by heavy storms-and later transported to marine ecosystems. In this study, we collected peat monoliths from drained, natural, and restored coastal peatlands in the Southeastern U.S., and conducted a microcosm experiment simulating coupled prolonged-drought and storm events to (1) test whether storms could trigger a pulse of nitrogen export from drought-stressed peatlands and (2) assess how differentially hydrologic managements through shifting plant communities affect nitrogen export by combining an experiment of nitrogen release from litter. During the drought phase, we observed a significant temporal variation in net nitrogen mineralization rate (NMR). NMR spiked in the third month and then decreased rapidly. This pattern indicates that drought duration significantly affects nitrogen mineralization in peat. NMR in the drained site reached up to 490±110kgha(-1)year(-1), about 5 times higher than in the restored site. After the 14-month drought phase, we simulated a heavy storm by bringing peat monoliths to saturation. In the discharge waters, concentrations of total dissolved nitrogen in the monoliths from the drained site (72.7±16.3mgL(-1)) was about ten times as high as from the restored site. Our results indicate that previously drained peatlands under prolonged drought are a potent source of nitrogen export. Moreover, drought-induced plant community shifts to herbaceous plants substantially raise nitrogen release with lasting effects by altering litter quality in peatlands

  3. Long-term hydrology and water quality of a drained pine plantation in North Carolina

    Science.gov (United States)

    D.M. Amatya; R.W. Skaggs

    2011-01-01

    Long-term data provide a basis for understanding natural variability, reducing uncertainty in model inputs and parameter estimation, and developing new hypotheses. This article evaluates 21 years (1988-2008) of hydrologic data and 17 years (1988-2005) of water quality data from a drained pine plantation in eastern North Carolina. The plantation age was 14 years at the...

  4. Complications corner: Anterior thoracic disc surgery with dural tear/CSF fistula and low-pressure pleural drain led to severe intracranial hypotension.

    Science.gov (United States)

    Oudeman, Eline A; Nandoe Tewarie, Rishi D S; Jöbsis, G Joost; Arts, Mark P; Kruyt, Nyika D

    2015-01-01

    Thoracic disc surgery can lead to a life-threatening complication: intracranial hypotension due to a subarachnoid-pleural fistula. We report a 63-year-old male with paraparesis due to multiple herniated thoracic discs, with compressive myelopathy. The patient required a circumferential procedure including a laminectomy/fusion followed by an anterior thoracic decompression to address both diffuse idiopathic skeletal hyperostosis (DISH) anteriorly and posterior stenosis. The postoperative course was complicated by severe intracranial hypotension attributed to the erroneous placement of a low-pressure drain placed in the pleural cavity instead of a lumbar drain; this resulted in subdural hematoma's necessitating subsequent surgery. Severe neurological deterioration occurring after thoracic decompressive surgery may rarely be attributed to intracranial hypotension due to a subarachnoid-pleural fistula. Patients should be treated with external lumbar drainage of cerebrospinal fluid for 3-5 days rather than a low-pressure pleural drain to avoid the onset of intracranial hypotension leading to symptomatic subdural hematomas.

  5. Effects of trap-assisted tunneling on gate-induced drain leakage in silicon-germanium channel p-type FET for scaled supply voltages

    Science.gov (United States)

    Tiwari, Vishal A.; Divakaruni, Rama; Hook, Terence B.; Nair, Deleep R.

    2016-04-01

    Silicon-germanium is considered as an alternative channel material to silicon p-type FET (pFET) for the development of energy efficient high performance transistors for 28 nm and beyond in a high-k metal gate technology because of its lower threshold voltage and higher mobility. However, gate-induced drain leakage (GIDL) is a concern for high threshold voltage device design because of tunneling at reduced bandgap. In this work, the trap-assisted tunneling and band-to-band tunneling (BTBT) effects on GIDL is analyzed and modeled for SiGe pFETs. Experimental results and Monte Carlo simulation results reveal that the pre-halo germanium pre-amorphization implant used to contain the short channel effects contribute to GIDL at the drain sidewall in addition to GIDL due to BTBT in SiGe devices. The results are validated by comparing the experimental observations with the numerical simulation and a set of calibrated models are used to describe the GIDL mechanisms for various drain and gate bias.

  6. On the theoretical–numerical study of the ITER Upper Port Plug structure hydraulic behaviour under steady state and draining and drying transient conditions

    International Nuclear Information System (INIS)

    Di Maio, P.A.; Paradiso, D.; Dell’Orco, G.; Pitcher, C.S.; Kalish, M.

    2011-01-01

    Highlights: ► UPP TS hydraulic behaviour has been investigated under steady state and D and D transient conditions. ► A thermal–hydraulic system code has been adopted and a UPP TS model has been set-up and validated against results of steady state CFD analyses. ► The TS steady state hydraulic characteristic functions have been derived for two coolant flow paths showing that right plate inlet one is the most promising. ► Draining simulations indicate that the 4 MPa injection pressure is high enough to drain almost completely the circuit in a reasonable time (∼6 s). ► Results indicate that right plate inlet flow path allows the TS complete draining, eliminating the need for the drying procedure. - Abstract: The ITER diagnostic Upper Port Plug (UPP) is a water-cooled stainless steel structure aimed to integrate within vacuum vessel the plasma diagnostic systems, shielding them from neutron and photon irradiation. Due to the very intense heat loads expected, a proper cooling circuit has been designed to ensure an adequate UPP cooling with an acceptable thermal rise and an unduly high pumping power and to perform its draining and drying procedure by injection of pressurized nitrogen. A theoretical research activity has been launched at the Department of Nuclear Engineering of the University of Palermo aiming to investigate the hydraulic behaviour of the UPP Trapezoid Section cooling circuit under steady state conditions and during its draining and drying transient procedure. The research activity has been performed following a theoretical–computational approach and adopting the RELAP5 thermal–hydraulic system code. The Trapezoid Section cooling circuit characteristic functions have been derived under steady state conditions at various coolant temperatures for both the coolant flow paths at the present under consideration for this circuit. The distributions of coolant mass flow rates along the channels of the cooling circuit have been calculated too

  7. Top-Contact Pentacene-Based Organic Thin Film Transistor (OTFT) with N, N'-Bis(3-Methyl Phenyl)- N, N'-Diphenyl Benzidine (TPD)/Au Bilayer Source-Drain Electrode

    Science.gov (United States)

    Borthakur, Tribeni; Sarma, Ranjit

    2018-01-01

    A top-contact Pentacene-based organic thin film transistor (OTFT) with N, N'-Bis (3-methyl phenyl)- N, N'-diphenyl benzidine (TPD)/Au bilayer source-drain electrode is reported. The devices with TPD/Au bilayer source-drain (S-D) electrodes show better performance than the single layer S-D electrode OTFT devices. The field-effect mobility of 4.13 cm2 v-1 s-1, the on-off ratio of 1.86 × 107, the threshold voltage of -4 v and the subthreshold slope of .27 v/decade, respectively, are obtained from the device with a TPD/Au bilayer source-drain electrode.

  8. Health workforce imbalances in times of globalization: brain drain or professional mobility?

    Science.gov (United States)

    Marchal, Bruno; Kegels, Guy

    2003-01-01

    The health workforce is of strategic importance to the performance of national health systems as well as of international disease control initiatives. The brain drain from rural to urban areas, and from developing to industrialized countries is a long-standing phenomenon in the health professions but has in recent years taken extreme proportions, particularly in Africa. Adopting the wider perspective of health workforce balances, this paper presents an analysis of the underlying mechanisms of health professional migration and possible strategies to reduce its negative impact on health services. The opening up of international borders for goods and labour, a key strategy in the current liberal global economy, is accompanied by a linguistic shift from 'human capital flight' and 'brain drain' to 'professional mobility' or 'brain circulation'. In reality, this mobility is very asymmetrical, to the detriment of less developed countries, which lose not only much-needed human resources, but also considerable investments in education and fiscal income. It is argued that low professional satisfaction and the decreasing social valuation of the health professionals are important determinants of the decreasing attraction of the health professions, which underlies both the push from the exporting countries, as well as the pull from the recipient countries. Solutions should therefore be based on this wider perspective, interrelating health workforce imbalances between, but also within developing and developed countries.

  9. Perspective analysis of tri gate germanium tunneling field-effect transistor with dopant segregation region at source/drain

    Science.gov (United States)

    Liu, Liang-kui; Shi, Cheng; Zhang, Yi-bo; Sun, Lei

    2017-04-01

    A tri gate Ge-based tunneling field-effect transistor (TFET) has been numerically studied with technology computer aided design (TCAD) tools. Dopant segregated Schottky source/drain is applied to the device structure design (DS-TFET). The characteristics of the DS-TFET are compared and analyzed comprehensively. It is found that the performance of n-channel tri gate DS-TFET with a positive bias is insensitive to the dopant concentration and barrier height at n-type drain, and that the dopant concentration and barrier height at a p-type source considerably affect the device performance. The domination of electron current in the entire BTBT current of this device accounts for this phenomenon and the tri-gate DS-TFET is proved to have a higher performance than its dual-gate counterpart.

  10. Prediction of phosphorus loads in an artificially drained lowland catchment using a modified SWAT model

    Science.gov (United States)

    Bauwe, Andreas; Eckhardt, Kai-Uwe; Lennartz, Bernd

    2017-04-01

    Eutrophication is still one of the main environmental problems in the Baltic Sea. Currently, agricultural diffuse sources constitute the major portion of phosphorus (P) fluxes to the Baltic Sea and have to be reduced to achieve the HELCOM targets and improve the ecological status. Eco-hydrological models are suitable tools to identify sources of nutrients and possible measures aiming at reducing nutrient loads into surface waters. In this study, the Soil and Water Assessment Tool (SWAT) was applied to the Warnow river basin (3300 km2), the second largest watershed in Germany discharging into the Baltic Sea. The Warnow river basin is located in northeastern Germany and characterized by lowlands with a high proportion of artificially drained areas. The aim of this study were (i) to estimate P loadings for individual flow fractions (point sources, surface runoff, tile flow, groundwater flow), spatially distributed on sub-basin scale. Since the official version of SWAT does not allow for the modeling of P in tile drains, we tested (ii) two different approaches of simulating P in tile drains by changing the SWAT source code. The SWAT source code was modified so that (i) the soluble P concentration of the groundwater was transferred to the tile water and (ii) the soluble P in the soil was transferred to the tiles. The SWAT model was first calibrated (2002-2011) and validated (1992-2001) for stream flow at 7 headwater catchments at a daily time scale. Based on this, the stream flow at the outlet of the Warnow river basin was simulated. Performance statistics indicated at least satisfactory model results for each sub-basin. Breaking down the discharge into flow constituents, it becomes visible that stream flow is mainly governed by groundwater and tile flow. Due to the topographic situation with gentle slopes, surface runoff played only a minor role. Results further indicate that the prediction of soluble P loads was improved by the modified SWAT versions. Major sources of

  11. Prolonged pericardial drainage using a soft drain reduces pericardial effusion and need for additional pericardial drainage following orthotopic heart transplantation.

    Science.gov (United States)

    Kim, Yun Seok; Jung, Sung-Ho; Cho, Won Chul; Yun, Sung-Cheol; Park, Jeong-Jun; Yun, Tae-Jin; Kim, Jae-Joong; Lee, Jae Won

    2016-03-01

    Pericardial effusion can cause haemodynamic compromise after heart transplantation. We identified the effects of soft drains on the development of pericardial effusion. We enrolled 250 patients ≥17 years of age who underwent heart transplantation between July 1999 and April 2012 and received two conventional tubes (n = 96; 32 French), or two tubes with a soft drain (n = 154; 4.8 mm wide). The development of significant pericardial effusion or the need for drainage procedure during 1 month after heart transplantation was compared with the use of the propensity score matching method to adjust for selection bias. At 1 month after transplantation, 69 patients (27.6%) developed significant pericardial effusion. Among these, 13 patients (5.2%) underwent pericardial drainage. According to multivariate analysis, history of previous cardiac surgery [odds ratio (OR) = 0.162; 95% confidence interval (CI) = 0.046-0.565; P = 0.004] and placement of a soft drain (OR = 0.186; 95% CI = 0.100-0.346; P effusion or the need for drainage during the early postoperative period. For the 82 propensity score matched pairs, patients receiving an additional soft drain were at a lower risk of the development of significant pericardial effusion or the need for a pericardial drainage procedure during 1 month (OR = 0.148; 95% CI = 0.068-0.318; P effusion and decreases the need for pericardial drainage after heart transplantation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Low-temperature formation of source–drain contacts in self-aligned amorphous oxide thin-film transistors

    NARCIS (Netherlands)

    Nag, M.; Muller, R.N.; Steudel, S.; Smout, S.; Bhoolokam, A.; Myny, K.; Schols, S.; Genoe, J.; Cobb, B.; Kumar, Abhishek; Gelinck, G.H.; Fukui, Y.; Groeseneken, G.; Heremans, P.

    2015-01-01

    We demonstrated self-aligned amorphous-Indium-Gallium-Zinc-Oxide (a-IGZO) thin-film transistors (TFTs) where the source–drain (S/D) regions were made conductive via chemical reduction of the a-IGZO via metallic calcium (Ca). Due to the higher chemical reactivity of Ca, the process can be operated at

  13. Subxyphoid pleural drain confers lesser impairment in respiratory muscle strength, oxygenation and lower chest pain after off-pump coronary artery bypass grafting: a randomized controlled trial.

    Science.gov (United States)

    Cancio, Andreia S A; Guizilini, Solange; Bolzan, Douglas W; Dauar, Renato B; Succi, José E; de Paola, Angelo A V; Carvalho, Antonio C de Camargo; Gomes, Walter J

    2012-01-01

    To evaluate respiratory muscle strength, oxygenation and chest pain in patients undergoing off-pump coronary artery bypass (OPCAB) using internal thoracic artery grafts comparing pleural drain insertion site at the subxyphoid region versus the lateral region. Forty patients were randomized into two groups in accordance with the pleural drain site. Group II (n = 19) -pleural drain exteriorized in the intercostal space; group (SI) (n = 21) chest tube exteriorized at the subxyphoid region. All patients underwent assessment of respiratory muscle strength (inspiratory and expiratory) on the pre, 1, 3 and 5 postoperative days (POD). Arterial blood gas analysis was collected on the pre and POD1. The chest pain sensation was measured 1, 3 and 5 POD. A significant decrease in respiratory muscle strength (inspiratory and expiratory) was seen in both groups until POD5 (P pleural drainage showed less decrease in respiratory muscle strength, better preservation of blood oxygenation and reduced thoracic pain compared to patients with intercostal drain on early OPCAB postoperative.

  14. Endoscopic Management of Drain Inclusion in the Gastric Pouch after Gastrojejunal Leakage after Laparoscopic Roux-en-Y Gastric Bypass for the Treatment of Morbid Obesity (LRYGBP

    Directory of Open Access Journals (Sweden)

    Ramon Vilallonga

    2010-01-01

    Patients. All four obese morbidly patients underwent LRYGBP and presented a gastro-jejunal fistula after acute anastomotic leakage. During follow-up endoscopy the drain was found inside the gastric pouch. It was moved into the abdominal cavity. Fistula debit reduced significantly and closed. Results. Gastric leak closure in less than 24 hours was achieved in all, with complete resolution of symptoms. These patients benefited exclusively from endoscopic treatment. Conclusions. Endoscopy is useful and technically feasible in chronic fistulas. This procedure is a less invasive alternative to traditional surgical revision. Other therapeutic strategies can be used such as clips and fibrin glue. Drains should not be placed in contact with the anastomosis or stapled lines. Drain inclusion must be suspected when fistula debit suddenly arises. If so, endoscopy is indicated for diagnostic accuracy. Under endoscopy vision, the drain is gently removed from the gastric reservoir leading to sudden and complete resolution of the fistula.

  15. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    Energy Technology Data Exchange (ETDEWEB)

    Teele, Sarah A.; Thiagarajan, Ravi R. [Children' s Hospital Boston, Department of Cardiology, Boston, MA (United States); Harvard Medical School, Department of Pediatrics, Boston, MA (United States); Emani, Sitaram M. [Children' s Hospital Boston, Department of Cardiac Surgery, Boston, MA (United States); Harvard Medical School, Department of Surgery, Boston, MA (United States); Teele, Rita L. [Harvard Medical School, Department of Radiology, Boston, MA (United States); Starship Children' s Hospital, Department of Radiology, Grafton (New Zealand)

    2008-10-15

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  16. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    International Nuclear Information System (INIS)

    Teele, Sarah A.; Thiagarajan, Ravi R.; Emani, Sitaram M.; Teele, Rita L.

    2008-01-01

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  17. Comment vieillissent les géofiltres ? Auscultation du dispositif expérimental de Roissard Geofilters ageing – Monitoring of Roissard expérimental draining trenches

    Directory of Open Access Journals (Sweden)

    FAURE, Yves-Henri ; VERSTAEVEL, Matthieu ; MERIAUX, Patrice ; VEYLON, Guillaume ; BARTHE, Matthieu ; BERTRAND, Cécile

    2012-08-01

    Full Text Available Les risques liés au vieillissement des géotextiles-filtres utilisés dans les ouvrages de drainage sont un enjeu majeur pour l’ingénierie des glissements de terrain et des ouvrages hydrauliques. Le projet DrainAgeing vise à mieux comprendre les phénomènes de vieillissement par colmatage de ces matériaux afin de mieux les prévenir et de formuler des recommandations pour les concepteurs et gestionnaires d’ouvrages.Risks related to geofilters ageing used in drainage are very important in the context of landslides stabilization engineering and dams and dikes design. “DrainAgeing” research project aims to a better understanding and prevention of drains ageing and clogging. This paper is about the state of progress of the project and the results of 18 years monitoring of Roissard experimental draining trenches. We conclude about the excavation and the analysis of geotextiles and geomaterials recently performed within the context of the second phase of the project.

  18. Stability performance and interface shear strength of geocomposite drain/soil systems

    Science.gov (United States)

    Othman, Maidiana; Frost, Matthew; Dixon, Neil

    2018-02-01

    Landfill covers are designed as impermeable caps on top of waste containment facilities after the completion of landfill operations. Geocomposite drain (GD) materials consist of a geonet or geospacer (as a drainage core) sandwiched between non-woven geotextiles that act as separators and filters. GD provides a drainage function as part of the cover system. The stability performance of landfill cover system is largely controlled by the interface shear strength mobilized between the elements of the cover. If a GD is used, the interface shear strength properties between the upper surface of the GD and the overlying soil may govern stability of the system. It is not uncommon for fine grained materials to be used as cover soils. In these cases, understanding soil softening issues at the soil interface with the non-woven geotextile is important. Such softening can be caused by capillary break behaviour and build-up of water pressures from the toe of the drain upwards into the cover soil. The interaction processes to allow water flow into a GD core through the soil-geotextile interface is very complex. This paper reports the main behaviour of in-situ interface shear strength of soil-GD using field measurements on the trial landfill cover at Bletchley, UK. The soil softening at the interface due to soaked behaviour show a reduction in interface shear strength and this aspect should be emphasized in design specifications and construction control. The results also help to increase confidence in the understanding of the implications for design of cover systems.

  19. Modified APEX model for Simulating Macropore Phosphorus Contributions to Tile Drains.

    Science.gov (United States)

    Ford, William I; King, Kevin W; Williams, Mark R; Confesor, Remegio B

    2017-11-01

    The contribution of macropore flow to phosphorus (P) loadings in tile-drained agricultural landscapes remains poorly understood at the field scale, despite the recognized deleterious impacts of contaminant transport via macropore pathways. A new subroutine that couples existing matrix-excess and matrix-desiccation macropore flow theory and a modified P routine is implemented in the Agricultural Policy Environmental eXtender (APEX) model. The original and modified formulation were applied and evaluated for a case study in a poorly drained field in Western Ohio with 31 months of surface and subsurface monitoring data. Results highlighted that a macropore subroutine in APEX improved edge-of-field discharge calibration and validation for both tile and total discharge from satisfactory and good, respectively, to very good and improved dissolved reactive P load calibration and validation statistics for tile P loads from unsatisfactory to very good. Output from the calibrated macropore simulations suggested median annual matrix-desiccation macropore flow contributions of 48% and P load contributions of 43%, with the majority of loading occurring in winter and spring. While somewhat counterintuitive, the prominence of matrix-desiccation macropore flow during seasons with less cracking reflects the importance of coupled development of macropore pathways and adequate supply of the macropore flow source. The innovative features of the model allow for assessments of annual macropore P contributions to tile drainage and has the potential to inform P site assessment tools. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. Sensitivity analysis of the agricultural policy/environmental extender (APEX) for phosphorus loads in tile-drained landscapes

    Science.gov (United States)

    Numerical modeling is an economical and feasible approach for quantifying the effects of best management practices on phosphorus (P) loadings from agricultural fields. However, tools that simulate both surface and subsurface P pathways are limited and have not been robustly evaluated in tile-drained...

  1. Remaining Sites Verification Package for the 100-F-46, 119-F Stack Sampling French Drain. Attachment to Waste Site Reclassification Form 2008-021

    International Nuclear Information System (INIS)

    Capron, J.M.

    2008-01-01

    The 100-F-46 french drain consisted of a 1.5 to 3 m long, vertically buried, gravel-filled pipe that was approximately 1 m in diameter. Also included in this waste site was a 5 cm cast-iron pipeline that drained condensate from the 119-F Stack Sampling Building into the 100-F-46 french drain. In accordance with this evaluation, the confirmatory sampling results support a reclassification of this site to No Action. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of confirmatory sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  2. Capacitorless one-transistor dynamic random-access memory based on asymmetric double-gate Ge/GaAs-heterojunction tunneling field-effect transistor with n-doped boosting layer and drain-underlap structure

    Science.gov (United States)

    Yoon, Young Jun; Seo, Jae Hwa; Kang, In Man

    2018-04-01

    In this work, we present a capacitorless one-transistor dynamic random-access memory (1T-DRAM) based on an asymmetric double-gate Ge/GaAs-heterojunction tunneling field-effect transistor (TFET) for DRAM applications. The n-doped boosting layer and gate2 drain-underlap structure is employed in the device to obtain an excellent 1T-DRAM performance. The n-doped layer inserted between the source and channel regions improves the sensing margin because of a high rate of increase in the band-to-band tunneling (BTBT) probability. Furthermore, because the gate2 drain-underlap structure reduces the recombination rate that occurs between the gate2 and drain regions, a device with a gate2 drain-underlap length (L G2_D-underlap) of 10 nm exhibited a longer retention performance. As a result, by applying the n-doped layer and gate2 drain-underlap structure, the proposed device exhibited not only a high sensing margin of 1.11 µA/µm but also a long retention time of greater than 100 ms at a temperature of 358 K (85 °C).

  3. A large-strain radial consolidation theory for soft clays improved by vertical drains

    OpenAIRE

    Geng, X; Yu, H-S

    2017-01-01

    A system of vertical drains with combined vacuum and surcharge preloading is an effective solution for promoting radial flow, accelerating consolidation. However, when a mixture of soil and water is deposited at a low initial density, a significant amount of deformation or surface settlement occurs. Therefore, it is necessary to introduce large-strain theory, which has been widely used to manage dredged disposal sites in one-dimensional theory, into radial consolidation theory. A governing eq...

  4. Ionic screening effect on low-frequency drain current fluctuations in liquid-gated nanowire FETs

    International Nuclear Information System (INIS)

    Lu, Ming-Pei; Vire, Eric; Montès, Laurent

    2015-01-01

    The ionic screening effect plays an important role in determining the fundamental surface properties within liquid–semiconductor interfaces. In this study, we investigated the characteristics of low-frequency drain current noise in liquid-gated nanowire (NW) field effect transistors (FETs) to obtain physical insight into the effect of ionic screening on low-frequency current fluctuation. When the NW FET was operated close to the gate voltage corresponding to the maximum transconductance, the magnitude of the low-frequency noise for the NW exposed to a low-ionic-strength buffer (0.001 M) was approximately 70% greater than that when exposed to a high-ionic-strength buffer (0.1 M). We propose a noise model, considering the charge coupling efficiency associated with the screening competition between the electrolyte buffer and the NW, to describe the ionic screening effect on the low-frequency drain current noise in liquid-gated NW FET systems. This report not only provides a physical understanding of the ionic screening effect behind the low-frequency current noise in liquid-gated FETs but also offers useful information for developing the technology of NW FETs with liquid-gated architectures for application in bioelectronics, nanosensors, and hybrid nanoelectronics. (paper)

  5. Analytical Model of Subthreshold Drain Current Characteristics of Ballistic Silicon Nanowire Transistors

    Directory of Open Access Journals (Sweden)

    Wanjie Xu

    2015-01-01

    Full Text Available A physically based subthreshold current model for silicon nanowire transistors working in the ballistic regime is developed. Based on the electric potential distribution obtained from a 2D Poisson equation and by performing some perturbation approximations for subband energy levels, an analytical model for the subthreshold drain current is obtained. The model is further used for predicting the subthreshold slopes and threshold voltages of the transistors. Our results agree well with TCAD simulation with different geometries and under different biasing conditions.

  6. Configuration of particle drain for the high energy charged particles in the magnetic dipole field

    International Nuclear Information System (INIS)

    Amirkhanov, I.V.; Zhidkov, E.P.; Ignatov, V.V.; Il'ina, A.N.; Il'in, V.D.; Kuznetsov, S.N.; Yushkov, B.Yu.

    1987-01-01

    The boundary of particle leakage from the magnetic dipole trap depending on the value of adiabatic parameter is investigated. By trajectory computation a generalized analytical expression is determined for the shape of particle drain by x ≤ 1. It is shown that generally accepted adiabatic loss cone is a particular case of x → 0

  7. Agrochemical loading in drains and rivers and its connection with pollution in coastal lagoons of the Mexican Pacific.

    Science.gov (United States)

    Arellano-Aguilar, Omar; Betancourt-Lozano, Miguel; Aguilar-Zárate, Gabriela; Ponce de Leon-Hill, Claudia

    2017-06-01

    The state of Sinaloa in Mexico is an industrialized agricultural region with a documented pesticide usage of 700 t year -1 ; which at least 17 of the pesticides are classified as moderately to highly toxic. Pollutants in the water column of rivers and drains are of great concern because the water flows into coastal lagoons and nearshore waters and thereby affects aquatic organisms. This study was done in four municipalities in the state of Sinaloa that produce food intensively. To investigate the link between pollution in the lagoons and their proximity to agricultural sites, water was sampled in three coastal lagoons and in the rivers and drains that flow into them. Seawater from the Gulf of California, 10 km from the coast, was also analyzed. Concentrations of nutrients, organochlorines, and organophosphorus pesticides were determined. Nutrient determination showed an unhealthy environment with N/P ratios of pollution of the coastal lagoon of Pabellones could be traced mainly to the drains from the agricultural sites. Accumulation of OC pesticides was also observed in the Gulf of California. Tests for 22 organophosphates revealed only five (diazinon, disulfoton, methyl parathion, chlorpyrifos, and mevinphos); diazinon was detected at all the sites, although methyl parathion was present at some sites at concentrations one order of magnitude higher than diazinon.

  8. Leaching of the Neonicotinoids Thiamethoxam and Imidacloprid from Sugar Beet Seed Dressings to Subsurface Tile Drains.

    Science.gov (United States)

    Wettstein, Felix E; Kasteel, Roy; Garcia Delgado, Maria F; Hanke, Irene; Huntscha, Sebastian; Balmer, Marianne E; Poiger, Thomas; Bucheli, Thomas D

    2016-08-24

    Pesticide transport from seed dressings toward subsurface tile drains is still poorly understood. We monitored the neonicotinoid insecticides imidacloprid and thiamethoxam from sugar beet seed dressings in flow-proportional drainage water samples, together with spray applications of bromide and the herbicide S-metolachlor in spring and the fungicides epoxiconazole and kresoxim-methyl in summer. Event-driven, high first concentration maxima up to 2830 and 1290 ng/L for thiamethoxam and imidacloprid, respectively, were followed by an extended period of tailing and suggested preferential flow. Nevertheless, mass recoveries declined in agreement with the degradation and sorption properties collated in the groundwater ubiquity score, following the order bromide (4.9%), thiamethoxam (1.2%), imidacloprid (0.48%), kresoxim-methyl acid (0.17%), S-metolachlor (0.032%), epoxiconazole (0.013%), and kresoxim-methyl (0.003%), and indicated increased leaching from seed dressings compared to spray applications. Measured concentrations and mass recoveries indicate that subsurface tile drains contribute to surface water contamination with neonicotinoids from seed dressings.

  9. Draining down of a nuclear steam generating system

    International Nuclear Information System (INIS)

    Jawor, J.C.

    1987-01-01

    The method is described of draining down contained reactor-coolant water from the inverted vertical U-tubes of a vertical-type steam generator in which the upper, inverted U-shaped ends of the tubes are closed and the lower ends thereof are open. The steam generator is part of a nuclear powered steam generating system wherein the reactor coolant water is normally circulated from and back into the reactor via a loop comprising the steam generator and inlet and outlet conduits connected to the lower end of the steam generator. The method comprises continuously introducing a gas which is inert to the system and which is under pressure above atmospheric pressure into at least one of the downwardly facing open ends of each of the U-tubes from below the tube sheet in which the open ends of the U-tubes are mounted adjacent the lower end of the steam generator, while permitting the water to flow out from the open ends of the U-tubes

  10. An analytical threshold voltage model for a short-channel dual-metal-gate (DMG) recessed-source/drain (Re-S/D) SOI MOSFET

    Science.gov (United States)

    Saramekala, G. K.; Santra, Abirmoya; Dubey, Sarvesh; Jit, Satyabrata; Tiwari, Pramod Kumar

    2013-08-01

    In this paper, an analytical short-channel threshold voltage model is presented for a dual-metal-gate (DMG) fully depleted recessed source/drain (Re-S/D) SOI MOSFET. For the first time, the advantages of recessed source/drain (Re-S/D) and of dual-metal-gate structure are incorporated simultaneously in a fully depleted SOI MOSFET. The analytical surface potential model at Si-channel/SiO2 interface and Si-channel/buried-oxide (BOX) interface have been developed by solving the 2-D Poisson’s equation in the channel region with appropriate boundary conditions assuming parabolic potential profile in the transverse direction of the channel. Thereupon, a threshold voltage model is derived from the minimum surface potential in the channel. The developed model is analyzed extensively for a variety of device parameters like the oxide and silicon channel thicknesses, thickness of source/drain extension in the BOX, control and screen gate length ratio. The validity of the present 2D analytical model is verified with ATLAS™, a 2D device simulator from SILVACO Inc.

  11. Biodiversity on mire ecosystems and drained peatlands - a basis for environmental peat harvesting; Biologisk maangfald paa myrar och dikad torvmark - underlag foer ett miljoemaessigt torvbruk

    Energy Technology Data Exchange (ETDEWEB)

    Stedingk, Henrik von (Swedish Biodiversity Centre, Uppsala (Sweden))

    2009-07-01

    The interest of peat harvesting has increased, due to the political ambition to reduce greenhouse gas emissions and to increase the use of local energy sources. Peatlands drained for forestry, a common resource in Sweden, can be a good energy source in terms of greenhouse gas emissions, under certain conditions. The question is what consequences increased peat harvesting would have on biodiversity in the forest landscape. To answer this question this literature study was performed to summarize what is known about the life of a natural and drained mire, and to discuss what conservation values could be found on a drained peatland. The definition of mire is a wetland with active peat accumulation, even if mires also are distinguished based on specific plant communities. A mire often contains several mire types. Some mire taxa are specialized for living on mires, other organisms have other main habitats but utilize the mire for fulfilling their life cycle. The level of knowledge varies for different organisms. The best known groups are vascular plants and bryophytes. They are also used for classifying mires since their abundance is related to gradients of pH, fertility and water level. Arthropods is a diverse group on mires favored by open moist forests and water pools. Poor mires with restricted flora may be good insect habitats. Birds are found in habitats rich in insects. Large mires are richer in wader species thanks to higher heterogeneity and a variety of insect habitats. The microscopic life in peat is rich and the species composition differs from the forest soil, even if the level of knowledge is limited. Drainage leads to species turn over for many groups of organisms and drainage often leads to a decrease in diversity. However, drained peatlands is a collective concept including different peatland types in different succession phases and different intensity of drainage. Therefore in general, drained peatlands cannot be treated as less important for

  12. To determine the slow shearing rate for consolidation drained shear box tests

    Science.gov (United States)

    Jamalludin, Damanhuri; Ahmad, Azura; Nordin, Mohd Mustaqim Mohd; Hashim, Mohamad Zain; Ibrahim, Anas; Ahmad, Fauziah

    2017-08-01

    Slope failures always occur in Malaysia especially during the rainy seasons. They cause damage to properties and fatalities. In this study, a total of 24 one dimensional consolidation tests were carried out on soil samples taken from 16 slope failures in Penang Island and in Baling, Kedah. The slope failures in Penang Island are within the granitic residual soil while in Baling, Kedah they are situated within the sedimentary residual soil. Most of the disturbed soil samples were taken at 100mm depth from the existing soil surface while some soil samples were also taken at 400, 700 and 1000mm depths from the existing soil surface. They were immediately placed in 2 layers of plastic bag to prevent moisture loss. Field bulk density tests were also carried out at all the locations where soil samples were taken. The field bulk density results were later used to re-compact the soil samples for the consolidation tests. The objective of the research is to determine the slow shearing rate to be used in consolidated drained shear box for residual soils taken from slope failures so that the effective shear strength parameters can be determined. One dimensional consolidation tests were used to determine the slow shearing rate. The slow shearing rate found in this study to be used in the consolidated drained shear box tests especially for Northern Malaysian residual soils was 0.286mm/minute.

  13. Investigation of the effects of slow-release fertilizer and struvite in biodegradation in filter drains and potential application of treated water in irrigation of road verges.

    Science.gov (United States)

    Theophilus, Stephen C; Mbanaso, Fredrick U; Nnadi, Ernest O; Onyedeke, Kingsley T

    2017-11-14

    Filter drains are usually laid along the margins of highways. Highway runoffs are polluted with hydrocarbons and high levels of total dissolved solids. Therefore, effective pollution removal mechanism is necessary in order to avoid contamination of surrounding soils and groundwater. Biodegradation is amongst pollution removal mechanisms in filter drains, but it is a relatively slow process which is dependent on wide range of factors including the type of pollutant and availability of nutrients. This paper reports on a study conducted to investigate the impact of slow-release fertilizer and struvite in enhancement of biodegradation of hydrocarbon in filter drains. Filter drain models incorporated with geotextile were challenged with cumulative oil loading of 178 mg/m 2 /week with a view to comparing the efficiency of these two nutrient sources under high oil pollution loading and realistic rainfall conditions of 13 mm/week. Nutrients and street dust were applied at one-off rate of 17 g/m 2 and 1.55 g/rig to provide nutrient enhancement and simulate field conditions respectively. The impact of the nutrients was studied by monitoring bacterial and fungal growth using nutrient agar, Rose Bengal Agar media and CO2 evolution. EC, pH, heavy metals, TPH, elemental analysis and SAR were used to investigate water quality of effluent of filter drains for potential application as irrigation fluid for trees and flowers planted on road verges. The results show that nutrient application encouraged microbial activities and enhanced biodegradation rates with differences in type of nutrient applied. Also, it was observed that incorporation of geotextiles in filter drains improved pollution retention efficiency and there is a potential opportunity for utilization of struvite in SuDS systems as sustainable nutrient source.

  14. Modeling the impact of nitrogen fertilizer application and tile drain configuration on nitrate leaching using SWAT

    Science.gov (United States)

    Recently, the Soil and Water Assessment Tool (SWAT) was revised to improve the partitioning of runoff and tile drainage in poorly drained soils by modifying the algorithm for computing the soil moisture retention parameter. In this study, the revised SWAT model was used to evaluate the sensitivity a...

  15. An Experimental Study of the Drained Capacity of Bucket Foundations for Offshore Applications

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Barari, Amin; Larsen, Kim André

    2013-01-01

    Today, wind energy offers the most competitive production prices for renewable energy. Therefore there are strong political and industrial forces, especially in northern Europe, which support the development of the offshore wind industry. The present paper presents the results of drained tests on....... Based on the results of the analyses, new failure criteria are calibrated for bucket foundations, in contrast to previous studies using the failure envelop e approach which have suggested that yield surface is constant in shape....

  16. Treatment of bilge and oily drain water of tankers and current measures against combustible oil gas discharge; Tanker no biruji yudakusui shori oyobi kanensei sekiyu gas haishutsu taiskau no genjo

    Energy Technology Data Exchange (ETDEWEB)

    Agatsuma, Y.

    1996-07-25

    This paper describes the current actual conditions on treatment of bilge discharged from engine area and oily drain water from cargo area of tankers. Clean bilge among various bilges discharged from engine area such as vapor drain, fresh water, rainwater, seawater and condensed water is directly dumped into the sea after temporary storage in a clean tank. Oily bilge is produced mainly by mixing of clean bilge and leakage oil from main engines and various auxiliaries. Oily bilge is dumped into the sea under comparative monitoring of the bilge quality with the dumping standard by oil concentration monitoring and control equipment after the primary treatment in a treatment tank and the secondary treatment in a bilge separator. Oily drain water from cargo area contains water ballast for cargo oil tanks, wash water for tanks and lines, and bilge produced in pump room. The oily drain water is dumped under a specific condition. However, water ballast for specific ballast tanks is excluded from the oily drain water. 2 figs.

  17. The role of external drains and peritoneal conduits in the treatment of recurrent chronic subdural hematoma.

    Science.gov (United States)

    Santarius, Thomas; Qureshi, Hammad U; Sivakumaran, Ram; Kirkpatrick, Peter J; Kirollos, Ramez W; Hutchinson, Peter J

    2010-06-01

    A considerable body of evidence supporting the use of external drainage after evacuation of primary chronic subdural hematoma (CSDH) exists in the literature. However, no systematic study of the value of postoperative drainage in the treatment of recurrent CSDH has been published. The aim of the study was to investigate external drains and subdural-to-peritoneal conduit in the treatment of recurrent CSDH. A retrospective review of cases of CSDH treated in our institution between October 2002 and October 2006 was conducted. During the study period, 408 patients had burr hole evacuation. Sixty-four patients (15.9%) had treatment for recurrence. One patient had craniotomy, and the remaining 63 had another burr hole evacuation: 36 without placement of a drain (BHO), 14 with external drainage (SED), and 13 with placement of subdural-peritoneal catheter (SPC). Fifteen patients (24%) developed a secondary recurrence requiring a third drainage procedure. Postoperative drainage (SED or SPC) was associated with a significantly lower secondary recurrence rate when compared to BHO: 3/27 (11%) versus 12/36 (33%) (χ(2), P=.040). There was no significant difference in recurrence rates between SED and SPC. Postoperative complications included acute subdural hematoma (2), subdural empyema (2), brain edema (2), pneumonia (3), and in-hospital death (2). None of the complications was associated with the use of a specific technique. The results indicate that, as in the treatment of primary CSDHs, the use of drain (SED or SPC) with burr hole evacuation is safe and is associated with lower recurrence rate. Further investigation is needed to clarify the indications of currently available surgical techniques in the treatment of recurrent CSDH. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Sub-xyphoid pleural drain as a determinant of functional capacity and clinical results after off-pump coronary artery bypass surgery: a randomized clinical trial.

    Science.gov (United States)

    Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J

    2014-09-01

    The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Gate voltage and drain current stress instabilities in amorphous In–Ga–Zn–O thin-film transistors with an asymmetric graphene electrode

    Directory of Open Access Journals (Sweden)

    Joonwoo Kim

    2015-09-01

    Full Text Available The gate voltage and drain current stress instabilities in amorphous In–Ga–Zn–O thin-film transistors (a-IGZO TFTs having an asymmetric graphene electrode structure are studied. A large positive shift in the threshold voltage, which is well fitted to a stretched-exponential equation, and an increase in the subthreshold slope are observed when drain current stress is applied. This is due to an increase in temperature caused by power dissipation in the graphene/a-IGZO contact region, in addition to the channel region, which is different from the behavior in a-IGZO TFTs with a conventional transparent electrode.

  20. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    International Nuclear Information System (INIS)

    Currarino, G.; Stannard, M.W.; Texas Univ., Dallas, TX; Kolni, H.

    1991-01-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.)

  1. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, G.; Stannard, M.W. (Children' s Medical Center, Dallas, TX (United States). Dept. of Radiology Texas Univ., Dallas, TX (United States). Southwestern Medical Center); Kolni, H. (Methodist Hospital, Dallas, TX (United States). Dept. of Pediatrics)

    1991-05-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.).

  2. Heterotrophic respiration in drained tropical peat temperatures influenced by shading gradient

    Science.gov (United States)

    Jauhiainen, Jyrki; Kerojoki, Otto; Silvennoinen, Hanna; Limin, Suwido; Vasander, Harri

    2015-04-01

    Lowland peatlands in Southeast Asia constitute a highly concentrated carbon (C) pool of global significance. These peatlands have formed over periods of several millennia by forest vegetation tolerant to flooding and poor substrates. Uncontrollable drainage and reoccurring wild fires in lack of management after removal of forest cover has impaired the C-storing functions in large reclaimed areas. Intergovernmental Panel on Climate Change (IPCC) reporting sees drained tropical organic soils as one of the largest greenhouse gas emissions releasing terrestrial systems. Vast areas of deforested tropical peatlands do not receive noteworthy shading by vegetation, which increases the amount of solar radiation reaching the peat surface. We studied heterotrophic carbon dioxide (CO2), nitrous oxide (N2O) and methane (CH4) fluxes in tropical peat in conditions, where; (i) peat temperatures were modified by artificial shading (no shade, 28%, 51% and 90% from the full sun exposure), (ii) root respiration was minimized, (iii) nutrient availability for peat decomposer community was changed (NPK fertilization of 0 and 313 kg ha-1). The experiment was repeated at two over 20 years ago drained fallow agricultural- and degraded sites in Central Kalimantan, Indonesia. Enhanced shading created a lasting decrease in peat temperatures, and decreased diurnal temperature fluctuations, in comparison to less shaded plots. The largest peat temperature difference was between the unshaded and 90% shaded peat surface, where the average temperatures within the topmost 50-cm peat profile differed 3 °C, and diurnal temperatures at 5 cm depth varied up to 4.2 °C in the unshaded and 0.4 °C in the 90% shaded conditions. Highest impacts on the heterotrophic CO2 fluxes caused by the treatments were on agricultural land, where 90% shading from the full exposure resulted in a 33% lower CO2 emission average on the unfertilised plots and a 66% lower emission average on the fertilised plots. Correlation

  3. Draining Water from Aircraft Fuel Using Nitrogen Enriched Air

    Directory of Open Access Journals (Sweden)

    Michael Frank

    2018-04-01

    Full Text Available This paper concerns a computational study of the process of removing water from an aircraft’s fuel tank by pumping nitrogen enriched air (NEA from the bottom of the tank. This is an important procedure for the smooth, efficient, and safe operation of the aircraft’s engine. Due to the low partial pressure of water in the pumped NEA, it absorbs water from the fuel. The water-laden bubbles enter the ullage, the empty space above the fuel, and escape into the environment. The effects of the number of NEA inlets and the NEA mass flow rate on the timescale of the NEA pumping were investigated using Computational Fluid Dynamics. The results reveal that the absorption of water by the NEA bubbles is low and is not affected by the number of the inlets used. Yet, the water content in the fuel decreases fast during the procedure, which is the desired outcome. We show that this is due to the relatively dry NEA entering the ullage and displacing the moist air, thus reducing the partial pressure of water at the fuel/ullage interface. This shift from equilibrium conditions forces water to evaporate from the fuel’s entire surface. Furthermore, the amount of water migrating from the fuel directly into the ullage is significantly greater than that absorbed by the rising bubbles. In turn, the rate of decrease of the water content in the ullage is determined by the total NEA mass flow rate and this is the dominant contributor to the draining time, with the number of NEA nozzles playing a minor role. We confirmed this by pumping NEA directly into the ullage, where we observe a significant decrease of water even when the NEA is not pumped through the fuel. We also show that doubling the mass flow rate halves the draining time. When considering the capability of most modern aircraft to pump NEA through the fuel as part of their inerting system, the proposed method for removing water is particularly attractive, requiring very little (if at all design modification.

  4. The effects of drain scatterings on the electron transport properties of strained-Si diodes with ballistic and non-ballistic channels

    International Nuclear Information System (INIS)

    Yasenjan Ghupur; Mamtimin Geni; Mamatrishat Mamat; Abudukelimu Abudureheman

    2015-01-01

    The effects of multiple scattering on the electron transport properties in drain regions are numerically investigated for the cases of strained-Si diodes with or without scattering in the channel. The performance of non-ballistic (with scattering) channel Si-diodes is compared with that of ballistic (without scattering) channel Si-diodes, using the strain and scattering model. Our results show that the values of the electron velocity and the current in the strain model are higher than the respective values in the unstrained model, and the values of the velocity and the current in the ballistic channel model are higher than the respective values in the non-ballistic channel model. In the strain and scattering models, the effect of each carrier scattering mechanism on the performance of the Si-diodes is analyzed in the drain region. For the ballistic channel model, our results show that inter-valley optical phonon scattering improves device performance, whereas intra-valley acoustic phonon scattering degrades device performance. For the strain model, our results imply that the larger energy splitting of the strained Si could suppress the inter-valley phonon scattering rate. In conclusion, for the drain region, investigation of the strained-Si and scattering mechanisms are necessary, in order to improve the performance of nanoscale ballistic regime devices. (paper)

  5. Technology CAD of silicided Schottky barrier MOSFET for elevated source-drain engineering

    International Nuclear Information System (INIS)

    Saha, A.R.; Chattopadhyay, S.; Bose, C.; Maiti, C.K.

    2005-01-01

    Technology CAD has been used to study the performance of a silicided Schottky barrier (SB) MOSFET with gate, source and drain contacts realized with nickel-silicide. Elevated source-drain structures have been used towards the S/D engineering of CMOS devices. A full process-to-device simulation has been employed to predict the performance of sub-micron SB n-MOSFETs for the first time. A model for the diffusion and alloy growth kinetics has been incorporated in SILVACO-ATLAS and ATHENA to explore the processing and design parameter space for the Ni-silicided MOSFETs. The temperature and concentration dependent diffusion model for NiSi have been developed and necessary material parameters for nickel-silicide and epitaxial-Si have been incorporated through the C-interpreter function. Two-dimensional (2D) process-to-device simulations have also been used to study the dc and ac (RF) performance of silicided Schottky barrier (SB) n-MOSFETs. The extracted sheet resistivity, as a function of annealing temperature of the silicided S/D contacts, is found to be lower than the conventional contacts currently in use. It is also shown that the Technology CAD has the full capability to predict the possible dc and ac performance enhancement of a MOSFET with elevated S/D structures. While the simulated dc performance shows a clear enhancement, the RF analyses show no performance degradation in the cut-off frequency/propagation delay and also improve the ac performance due to the incorporation of silicide contacts in the S/D region

  6. Technology CAD of silicided Schottky barrier MOSFET for elevated source-drain engineering

    Energy Technology Data Exchange (ETDEWEB)

    Saha, A.R. [Department of Electronics and ECE, IIT, Kharagpur 721302 (India)]. E-mail: ars.iitkgp@gmail.com; Chattopadhyay, S. [Department of Electronics and ECE, IIT, Kharagpur 721302 (India); School of Electrical, Electronics and Computer Engineering, University of Newcastle, Newcastle upon Tyne (United Kingdom); Bose, C. [Department of Electronics and Telecommunication Engineering, Jadavpur University, Calcutta 700032 (India); Maiti, C.K. [Department of Electronics and ECE, IIT, Kharagpur 721302 (India)

    2005-12-05

    Technology CAD has been used to study the performance of a silicided Schottky barrier (SB) MOSFET with gate, source and drain contacts realized with nickel-silicide. Elevated source-drain structures have been used towards the S/D engineering of CMOS devices. A full process-to-device simulation has been employed to predict the performance of sub-micron SB n-MOSFETs for the first time. A model for the diffusion and alloy growth kinetics has been incorporated in SILVACO-ATLAS and ATHENA to explore the processing and design parameter space for the Ni-silicided MOSFETs. The temperature and concentration dependent diffusion model for NiSi have been developed and necessary material parameters for nickel-silicide and epitaxial-Si have been incorporated through the C-interpreter function. Two-dimensional (2D) process-to-device simulations have also been used to study the dc and ac (RF) performance of silicided Schottky barrier (SB) n-MOSFETs. The extracted sheet resistivity, as a function of annealing temperature of the silicided S/D contacts, is found to be lower than the conventional contacts currently in use. It is also shown that the Technology CAD has the full capability to predict the possible dc and ac performance enhancement of a MOSFET with elevated S/D structures. While the simulated dc performance shows a clear enhancement, the RF analyses show no performance degradation in the cut-off frequency/propagation delay and also improve the ac performance due to the incorporation of silicide contacts in the S/D region.

  7. Thermo-mechanical Properties of Upper Jurassic (Malm) Carbonate Rock Under Drained Conditions

    Science.gov (United States)

    Pei, Liang; Blöcher, Guido; Milsch, Harald; Zimmermann, Günter; Sass, Ingo; Huenges, Ernst

    2018-01-01

    The present study aims to quantify the thermo-mechanical properties of Neuburger Bankkalk limestone, an outcrop analog of the Upper Jurassic carbonate formation (Germany), and to provide a reference for reservoir rock deformation within future enhanced geothermal systems located in the Southern German Molasse Basin. Experiments deriving the drained bulk compressibility C were performed by cycling confining pressure p c between 2 and 50 MPa at a constant pore pressure p p of 0.5 MPa after heating the samples to defined temperatures between 30 and 90 °C. Creep strain was then measured after each loading and unloading stage, and permeability k was obtained after each creep strain measurement. The drained bulk compressibility increased with increasing temperature and decreased with increasing differential pressure p d = p c - p p showing hysteresis between the loading and unloading stages above 30 °C. The apparent values of the indirectly calculated Biot coefficient α ind containing contributions from inelastic deformation displayed the same temperature and pressure dependencies. The permeability k increased immediately after heating and the creep rates were also temperature dependent. It is inferred that the alteration of the void space caused by temperature changes leads to the variation of rock properties measured under isothermal conditions while the load cycles applied under isothermal conditions yield additional changes in pore space microstructure. The experimental results were applied to a geothermal fluid production scenario to constrain drawdown and time-dependent effects on the reservoir, overall, to provide a reference for the hydromechanical behavior of geothermal systems in carbonate, and more specifically, in Upper Jurassic lithologies.

  8. RF dynamic and noise performance of Metallic Source/Drain SOI n-MOSFETs

    Science.gov (United States)

    Martin, Maria J.; Pascual, Elena; Rengel, Raúl

    2012-07-01

    This paper presents a detailed study of the RF and noise performance of n-type Schottky barrier (SB) MOSFETs with a particular focus on the influence of the Schottky barrier height (SBH) on the main dynamic and noise figures of merit. With this aim, a 2D Monte Carlo simulator including tunnelling transport across Schottky interfaces has been developed, with special care to consider quantum transmission coefficients and the influence of image charge effects at the Schottky junctions. Particular attention is paid to the microscopic transport features, including carrier mean free paths or number of scattering events along the channel for investigating the optimization of the device topology and the strategic concepts related to the noise performance of this new architecture. A more effective control of the gate electrode over drain current for low SBH (discussed in terms of internal physical quantities) is translated into an enhanced transconductance gm, cut-off frequency fT, and non-quasistatic dynamic parameters. The drain and gate intrinsic noise sources show a noteworthy degradation with the SBH reduction due to the increased current, influence of hot carriers and reduced number of phonon scatterings. However, the results evidence that this effect is counterbalanced by the extremely improved dynamic performance in terms of gm and fT. Therefore, the deterioration of the intrinsic noise performance of the SB-MOSFET has no significant impact on high-frequency noise FoMs as NFmin, Rn and Gass for low SBH and large gate overdrive conditions. The role of the SBH on Γopt, optimum noise reactance and susceptance has been also analyzed.

  9. Pleural subxyphoid drain confers better pulmonary function and clinical outcomes in chronic obstructive pulmonary disease after off-pump coronary artery bypass grafting: a randomized controlled trial.

    Science.gov (United States)

    Guizilini, Solange; Viceconte, Marcela; Esperança, Gabriel Tavares da M; Bolzan, Douglas W; Vidotto, Milena; Moreira, Rita Simone L; Câncio, Andréia Azevedo; Gomes, Walter J

    2014-01-01

    To evaluate the lung function and clinical outcome in severe chronic obstructive pulmonary disease in patients undergoing off-pump coronary artery bypass grafting with left internal thoracic artery graft, comparing the pleural drain insertion in the intercostal versus subxyphoid region. A randomized controlled trial. Chronic obstructive pulmonary disease patients were randomized into two groups according pleural drain site: II group (n=27) - pleural drain in intercostal space; SI group (n=29) - pleural drain in the subxyphoid region. Spirometry values (Forced Vital Capacity - and Forced expiratory volume in 1 second) were obtained on preoperative and 1, 3 and 5 postoperative days. Chest x-ray from preoperative until postoperative day 5 (POD5) was performed for monitoring respiratory events, such as atelectasis and pleural effusion. Pulmonary shunt fraction and pain score was evaluate preoperatively and on postoperative day 1. In both groups there was a significant decrease of the spirometry values (Forced Vital Capacity and Forced expiratory volume in 1 second) until POD5 (Ppleural drainage in severe Chronic obstructive pulmonary disease patients determined better preservation and recovery of pulmonary capacity and volumes with lower pulmonary shunt fraction and better clinical outcomes on early postoperative off-pump coronary artery bypass grafting.

  10. Modeling the effects of tile drain placement on the hydrologic function of farmed prairie wetlands

    Science.gov (United States)

    Werner, Brett; Tracy, John; Johnson, W. Carter; Voldseth, Richard A.; Guntenspergen, Glenn R.; Millett, Bruce

    2016-01-01

    The early 2000s saw large increases in agricultural tile drainage in the eastern Dakotas of North America. Agricultural practices that drain wetlands directly are sometimes limited by wetland protection programs. Little is known about the impacts of tile drainage beyond the delineated boundaries of wetlands in upland catchments that may be in agricultural production. A series of experiments were conducted using the well-published model WETLANDSCAPE that revealed the potential for wetlands to have significantly shortened surface water inundation periods and lower mean depths when tile is placed in certain locations beyond the wetland boundary. Under the soil conditions found in agricultural areas of South Dakota in North America, wetland hydroperiod was found to be more sensitive to the depth that drain tile is installed relative to the bottom of the wetland basin than to distance-based setbacks. Because tile drainage can change the hydrologic conditions of wetlands, even when deployed in upland catchments, tile drainage plans should be evaluated more closely for the potential impacts they might have on the ecological services that these wetlands currently provide. Future research should investigate further how drainage impacts are affected by climate variability and change.

  11. Photometric determination of trace cadmium in waste water drained from uranium mining and water-metallurgy

    International Nuclear Information System (INIS)

    Zhu Zihui; Gu Gang; Xu Quanxiu

    1987-09-01

    Cadmium (Cd) ions react with dithizone to form a pink to red color that can be extracted with chloroform and measured photometrically. Dithizone method is one of standard method to determine trace Cd in the environmental waste water. This method, however, can not be suitable for measuring the trace Cd in the waste water drained from uranium mining and water-metallurgy factory, because this kind of waste water contains magnesium ions as high as 1500 mg/L. One more discomfort is that the method needs to use a large amount of potassium cyanide. The authors, therefore, used potassium fluorine as a precipitator that removed the excess magnesium ions in the experimental system, and try to reduce the amount of potassium cyanide to 1/20 of original usage. The experimental results indicated that the modified method as mentioned above was very satisfactory either to simulated samples or to actual samples of waste water drained from uranium mining and water-metallurgy plants. In Summary, this modified method has higher sensitivity with minimun detectable quantity of 0.02 ppm and it is accurate and reproducible with recovery rate of 100 ± 5%

  12. Trapping in GaN-based metal-insulator-semiconductor transistors: Role of high drain bias and hot electrons

    Energy Technology Data Exchange (ETDEWEB)

    Meneghini, M., E-mail: matteo.meneghini@dei.unipd.it; Bisi, D.; Meneghesso, G.; Zanoni, E. [Department of Information Engineering, University of Padova, via Gradenigo 6/B, 35131 Padova (Italy); Marcon, D.; Stoffels, S.; Van Hove, M.; Wu, T.-L.; Decoutere, S. [IMEC, Kapeldreef 75, 3001 Heverlee (Belgium)

    2014-04-07

    This paper describes an extensive analysis of the role of off-state and semi-on state bias in inducing the trapping in GaN-based power High Electron Mobility Transistors. The study is based on combined pulsed characterization and on-resistance transient measurements. We demonstrate that—by changing the quiescent bias point from the off-state to the semi-on state—it is possible to separately analyze two relevant trapping mechanisms: (i) the trapping of electrons in the gate-drain access region, activated by the exposure to high drain bias in the off-state; (ii) the trapping of hot-electrons within the AlGaN barrier or the gate insulator, which occurs when the devices are operated in the semi-on state. The dependence of these two mechanisms on the bias conditions and on temperature, and the properties (activation energy and cross section) of the related traps are described in the text.

  13. Study of novel junctionless Ge n-Tunneling Field-Effect Transistors with lightly doped drain (LDD) region

    Science.gov (United States)

    Liu, Xiangyu; Hu, Huiyong; Wang, Bin; Wang, Meng; Han, Genquan; Cui, Shimin; Zhang, Heming

    2017-02-01

    In this paper, a novel junctionless Ge n-Tunneling Field-Effect Transistors (TFET) structure is proposed. The simulation results show that Ion = 5.5 × 10-5A/μm is achieved. The junctionless device structure enhances Ion effectively and increases the region where significant BTBT occurs, comparing with the normal Ge-nTEFT. The impact of the lightly doped drain (LDD) region is investigated. A comparison of Ion and Ioff of the junctionless Ge n-TFET with different channel doping concentration ND and LDD doping concentration NLDD is studied. Ioff is reduced 1 order of magnitude with the optimized ND and NLDD are 1 × 1018cm-3 and 1 × 1017 cm-3, respectively. To reduce the gate induced drain leakage (GIDL) current, the impact of the sloped gate oxide structure is also studied. By employing the sloped gate oxide structure, the below 60 mV/decade subthreshold swing S = 46.2 mV/decade is achieved at Ion = 4.05 × 10-5A/μm and Ion/Ioff = 5.7 × 106.

  14. Quantum confinement effects and source-to-drain tunneling in ultra-scaled double-gate silicon n-MOSFETs

    International Nuclear Information System (INIS)

    Jiang Xiang-Wei; Li Shu-Shen

    2012-01-01

    By using the linear combination of bulk band (LCBB) method incorporated with the top of the barrier splitting (TBS) model, we present a comprehensive study on the quantum confinement effects and the source-to-drain tunneling in the ultra-scaled double-gate (DG) metal—oxide—semiconductor field-effect transistors (MOSFETs). A critical body thickness value of 5 nm is found, below which severe valley splittings among different X valleys for the occupied charge density and the current contributions occur in ultra-thin silicon body structures. It is also found that the tunneling current could be nearly 100% with an ultra-scaled channel length. Different from the previous simulation results, it is found that the source-to-drain tunneling could be effectively suppressed in the ultra-thin body thickness (2.0 nm and below) by the quantum confinement and the tunneling could be suppressed down to below 5% when the channel length approaches 16 nm regardless of the body thickness. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  15. Microdose Induced Drain Leakage Effects in Power Trench MOSFETs: Experiment and Modeling

    Science.gov (United States)

    Zebrev, Gennady I.; Vatuev, Alexander S.; Useinov, Rustem G.; Emeliyanov, Vladimir V.; Anashin, Vasily S.; Gorbunov, Maxim S.; Turin, Valentin O.; Yesenkov, Kirill A.

    2014-08-01

    We study experimentally and theoretically the micro-dose induced drain-source leakage current in the trench power MOSFETs under irradiation with high-LET heavy ions. We found experimentally that cumulative increase of leakage current occurs by means of stochastic spikes corresponding to a strike of single heavy ion into the MOSFET gate oxide. We simulate this effect with the proposed analytic model allowing to describe (including Monte Carlo methods) both the deterministic (cumulative dose) and stochastic (single event) aspects of the problem. Based on this model the survival probability assessment in space heavy ion environment with high LETs was proposed.

  16. CT changes in children with drained hydrocephalus and intermittently raised intracranial pressure

    International Nuclear Information System (INIS)

    Schmidt, H.; Korinthenberg, R.; Erlemann, R.; Lengerke, H.J. von; Muenster Univ.

    1987-01-01

    Seven children with drained hydrocephalus are described who showed increasingly severe and frequent episodes of intermittently raised intracranial pressure. CT examinations during symptom-free intervals, or after conservative treatment, showed collapsed slit-like ventricles. Examination during attacks of raised pressure showed relative dilatation of the ventricles as compared with earlier examinations. Children with ventricular shunts of long duration may develop a shunt-dependent syndrome; CT may show normal or narrow ventricles and this does not exclude the possibility of a rise of intracranial pressure. These findings may help in making the diagnosis by means of CT without any further invasive procedure. (orig.) [de

  17. Phosphorus Dynamics in Long-Term Flooded, Drained, and Reflooded Soils

    Directory of Open Access Journals (Sweden)

    Juan Tian

    2017-07-01

    Full Text Available In flooded areas, soils are often exposed to standing water and subsequent drainage, thus over fertilization can release excess phosphorus (P into surface water and groundwater. To investigate P release and transformation processes in flooded alkaline soils, wheat-growing soil and vegetable-growing soil were selected. We flooded-drained-reflooded two soils for 35 d, then drained the soils, and 10 d later reflooded the soils for 17 d. Dissolved reactive phosphorus (DRP, soil inorganic P fractions, Olsen P, pH, and Eh in floodwater and pore water were analyzed. The wheat-growing soil had significantly higher floodwater DRP concentrations than vegetable-growing soil, and floodwater DRP in both soils decreased with the number of flooding days. During the reflooding period, DRP in overlying floodwater from both soils was less than 0.87 mg/L, which was 3–25 times less than that during the flooding period. Regardless of flooding or reflooding, pore water DRP decreased with flooding days. The highest concentration of pore water DRP observed at a 5-cm depth. Under the effect of fertilizing and flooding, the risk of vertical P movement in 10–50 cm was enhanced. P diffusion occurred from the top to the bottom of the soils. After flooding, Al-P increased in both soils, and Fe-P, O-P, Ca2-P decreased, while Fe-P, Al-P, and O-P increased after reflooding, When Olsen P in the vegetable-growing soil exceeded 180.7 mg/kg and Olsen P in the wheat-growing soil exceeded 40.8 mg/kg, the concentration of DRP in pore water increased significantly. Our results showed that changes in floodwater and pore water DRP concentrations, soil inorganic P fractions, and Olsen P are significantly affected by fertilizing and flooding; therefore, careful fertilizer management should be employed on flooded soils to avoid excess P loss.

  18. Effect of drain current on appearance probability and amplitude of random telegraph noise in low-noise CMOS image sensors

    Science.gov (United States)

    Ichino, Shinya; Mawaki, Takezo; Teramoto, Akinobu; Kuroda, Rihito; Park, Hyeonwoo; Wakashima, Shunichi; Goto, Tetsuya; Suwa, Tomoyuki; Sugawa, Shigetoshi

    2018-04-01

    Random telegraph noise (RTN), which occurs in in-pixel source follower (SF) transistors, has become one of the most critical problems in high-sensitivity CMOS image sensors (CIS) because it is a limiting factor of dark random noise. In this paper, the behaviors of RTN toward changes in SF drain current conditions were analyzed using a low-noise array test circuit measurement system with a floor noise of 35 µV rms. In addition to statistical analysis by measuring a large number of transistors (18048 transistors), we also analyzed the behaviors of RTN parameters such as amplitude and time constants in the individual transistors. It is demonstrated that the appearance probability of RTN becomes small under a small drain current condition, although large-amplitude RTN tends to appear in a very small number of cells.

  19. DRAINMOD-FOREST: Integrated Modeling of Hydrology, Soil Carbon and Nitrogen Dynamics, and Plant Growth for Drained Forests.

    Science.gov (United States)

    Tian, Shiying; Youssef, Mohamed A; Skaggs, R Wayne; Amatya, Devendra M; Chescheir, G M

    2012-01-01

    We present a hybrid and stand-level forest ecosystem model, DRAINMOD-FOREST, for simulating the hydrology, carbon (C) and nitrogen (N) dynamics, and tree growth for drained forest lands under common silvicultural practices. The model was developed by linking DRAINMOD, the hydrological model, and DRAINMOD-N II, the soil C and N dynamics model, to a forest growth model, which was adapted mainly from the 3-PG model. The forest growth model estimates net primary production, C allocation, and litterfall using physiology-based methods regulated by air temperature, water deficit, stand age, and soil N conditions. The performance of the newly developed DRAINMOD-FOREST model was evaluated using a long-term (21-yr) data set collected from an artificially drained loblolly pine ( L.) plantation in eastern North Carolina, USA. Results indicated that the DRAINMOD-FOREST accurately predicted annual, monthly, and daily drainage, as indicated by Nash-Sutcliffe coefficients of 0.93, 0.87, and 0.75, respectively. The model also predicted annual net primary productivity and dynamics of leaf area index reasonably well. Predicted temporal changes in the organic matter pool on the forest floor and in forest soil were reasonable compared to published literature. Both predicted annual and monthly nitrate export were in good agreement with field measurements, as indicated by Nash-Sutcliffe coefficients above 0.89 and 0.79 for annual and monthly predictions, respectively. This application of DRAINMOD-FOREST demonstrated its capability for predicting hydrology and C and N dynamics in drained forests under limited silvicultural practices. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. Stress corrosion on austenitic stainless steels components after sodium draining

    International Nuclear Information System (INIS)

    Champeix, L.; Baque, P.; Chairat, C.

    1980-04-01

    The damage study performed on 316 pipes of a loop after two leakages allows to conclude that a stress corrosion process in sodium hydroxide environment has induced trans-crystaline cracks. The research of conditions inducing such a phenomenon is developed, including parametric tests under uniaxial load and some tests on pipe with welded joints. In aqueous sodium hydroxide, two corrosion processes have been revealed: a general oxidization increasing with environment aeration and a transcrystalline cracking appearing for stresses of the order of yield strength. Other conditions such a temperature (upper than 100 0 C) and time exposures (some tens of hours) are necessary. Cautions in order to limit introduction of wet air into drained loop and a choice of appropriate preheating conditions when restarting the installation must permit to avoid such a type of incident

  1. ROMANIA’S MEDICAL SECTOR: BETWEEN BRAIN DRAIN AND BRAIN WASTE

    Directory of Open Access Journals (Sweden)

    Irina BONCEA

    2015-04-01

    Full Text Available The aim of this article is to identify whether Romania is facing the brain waste in the medical sector. Romania is producing the highest number of medical graduates compared to the main destination countries for Romanian physicians.However, it faces critical shortages in terms of health professionals. What happens with these medical graduates? Two options are possible: either they exit the medical system or they emigrate. Medical doctors accepting locum doctors positions in United Kingdom or general practitioner positions in the rural areas in France although they have a specialty in the origin country are examples of brain waste. In most of the cases, these positions are refused by natives. If the brain drain has negative consequences on the origin country, brain waste affects both the country and the individual.

  2. 14 French pigtail catheters placed by surgeons to drain blood on trauma patients: is 14-Fr too small?

    Science.gov (United States)

    Kulvatunyou, Narong; Joseph, Bellal; Friese, Randall S; Green, Donald; Gries, Lynn; O'Keeffe, Terence; Tang, Andy L; Wynne, Julie L; Rhee, Peter

    2012-12-01

    Small 14F pigtail catheters (PCs) have been shown to drain air quite well in patients with traumatic pneumothorax (PTX). But their effectiveness in draining blood in patients with traumatic hemothorax (HTX) or hemopneumothorax (HPTX) is unknown. We hypothesized that 14F PCs can drain blood as well as large-bore 32F to 40F chest tubes. We herein report our early case series experience with PCs in the management of traumatic HTX and HPTX. We prospectively collected data on all bedside-inserted PCs in patients with traumatic HTX or HPTX during a 30-month period (July 2009 through December 2011) at our Level I trauma center. We then compared our PC prospective data with our trauma registry-derived retrospective chest tube data (January 2008 through December 2010) at our center. Our primary outcome of interest was the initial drainage output. Our secondary outcomes were tube duration, insertion-related complications, and failure rate. For our statistical analysis, we used the unpaired Student's t-test, χ test, and Wilcoxon rank-sum test; we defined significance by a value of p tubes. Our PC group had a higher rate of blunt mechanism injuries than our chest tube group did (83 vs. 62%; p = 0.01). The mean initial output was similar between our PC group (560 ± 81 mL) and our chest tube group (426 ± 37 mL) (p = 0.13). In the PC group, the tube was inserted later (median, Day 1; interquartile range, Days 0-3) than the tube inserted in our chest tube group (median, Day 0; interquartile range, Days 0-0) (p Tube duration, rate of insertion-related complications, and failure rate were all similar. In our early experience, 14F PCs seemed to drain blood as well as large-bore chest tubes based on initial drainage output and other outcomes studied. In this early phase, we were being selective in inserting PCs in only stable blunt trauma patients, and PCs were inserted at a later day from the time of the initial evaluation. In the future, we will need a larger sample size and

  3. Subthreshold Current and Swing Modeling of Gate Underlap DG MOSFETs with a Source/Drain Lateral Gaussian Doping Profile

    Science.gov (United States)

    Singh, Kunal; Kumar, Sanjay; Goel, Ekta; Singh, Balraj; Kumar, Mirgender; Dubey, Sarvesh; Jit, Satyabrata

    2017-01-01

    This paper proposes a new model for the subthreshold current and swing of the short-channel symmetric underlap ultrathin double gate metal oxide field effect transistors with a source/drain lateral Gaussian doping profile. The channel potential model already reported earlier has been utilized to formulate the closed form expression for the subthreshold current and swing of the device. The effects of the lateral straggle and geometrical parameters such as the channel length, channel thickness, and oxide thickness on the off current and subthreshold slope have been demonstrated. The devices with source/drain lateral Gaussian doping profiles in the underlap structure are observed to be highly resistant to short channel effects while improving the current drive. The proposed model is validated by comparing the results with the numerical simulation data obtained by using the commercially available ATLAS™, a two-dimensional (2-D) device simulator from SILVACO.

  4. Drain-induced barrier lowering effect for short channel dual material gate 4H silicon carbide metal—semiconductor field-effect transistor

    Science.gov (United States)

    Zhang, Xian-Jun; Yang, Yin-Tang; Duan, Bao-Xing; Chai, Chang-Chun; Song, Kun; Chen, Bin

    2012-09-01

    Sub-threshold characteristics of the dual material gate 4H-SiC MESFET (DMGFET) are investigated and the analytical models to describe the drain-induced barrier lowering (DIBL) effect are derived by solving one- and two-dimensional Poisson's equations. Using these models, we calculate the bottom potential of the channel and the threshold voltage shift, which characterize the drain-induced barrier lowering (DIBL) effect. The calculated results reveal that the dual material gate (DMG) structure alleviates the deterioration of the threshold voltage and thus suppresses the DIBL effect due to the introduced step function, which originates from the work function difference of the two gate materials when compared with the conventional single material gate metal—semiconductor field-effect transistor (SMGFET).

  5. Drain-induced barrier lowering effect for short channel dual material gate 4H silicon carbide metal—semiconductor field-effect transistor

    International Nuclear Information System (INIS)

    Zhang Xian-Jun; Yang Yin-Tang; Duan Bao-Xing; Chai Chang-Chun; Song Kun; Chen Bin

    2012-01-01

    Sub-threshold characteristics of the dual material gate 4H-SiC MESFET (DMGFET) are investigated and the analytical models to describe the drain-induced barrier lowering (DIBL) effect are derived by solving one- and two-dimensional Poisson's equations. Using these models, we calculate the bottom potential of the channel and the threshold voltage shift, which characterize the drain-induced barrier lowering (DIBL) effect. The calculated results reveal that the dual material gate (DMG) structure alleviates the deterioration of the threshold voltage and thus suppresses the DIBL effect due to the introduced step function, which originates from the work function difference of the two gate materials when compared with the conventional single material gate metal—semiconductor field-effect transistor (SMGFET)

  6. A large strain radial consolidation theory for soft clays improved by vertical drains\\ud

    OpenAIRE

    Geng, Xueyu; Yu, Hai-sui

    2017-01-01

    A system of vertical drains with combined vacuum and surcharge preloading is an effective 10 solution for promoting radial flow, accelerating consolidation. However, when a mixture of soil and\\ud 11 water is deposited at a low initial density, a significant amount of deformation or surface settlement 12 occurs. Therefore, it is necessary to introduce large strain theory, which has been widely used to manage\\ud 13 dredged disposal sites in one-dimensional theory, into radial consolidation theo...

  7. Heterotrophic soil respiration in forestry-drained peatlands

    International Nuclear Information System (INIS)

    Minkkinen, K.; Shurpali, N. J.; Alm, J.; Penttilae, T.

    2007-01-01

    Heterotrophic soil respiration (CO 2 efflux from the decomposition of peat and root litter) in three forestry-drained peatlands with different site types and with a large climatic gradient from the hemi-boreal (central Estonia) to south (southern Finland) and north boreal (northern Finland) conditions was studied. Instantaneous fluxes varied between 0 and 1.3 g CO 2 -C m -2 h -1 , and annual fluxes between 248 and 515 g CO 2 -C m -2 a -1 . Variation in the annual fluxes among site types was studied only in the south-boreal site where we found a clear increase from nutrient-poor to nutrient-rich site types. More than half of the within-site variation was temporal and explained by soil surface (-5 cm) temperature (T5). The response of soil respiration to T5 varied between the sites; the most northerly site had the highest response to T5 and the most southerly the lowest. This trend further resulted in increased annual fluxes towards north. This unexpected result is hypothesised to be related to differences in site factors like substrate quality, nutrient status and hydrology but also to temperature acclimation, i.e., adaptation of decomposer populations to different climates. (orig.)

  8. Toward the modeling of mucus draining from the human lung: role of the geometry of the airway tree

    International Nuclear Information System (INIS)

    Mauroy, Benjamin; Merckx, Jacques; Flaud, Patrice; Fausser, Christian; Pelca, Dominique

    2011-01-01

    Mucociliary clearance and cough are the two main natural mucus draining methods in the bronchial tree. If they are affected by a pathology, they can become insufficient or even ineffective, then therapeutic draining of mucus plays a critical role to keep mucus levels in the lungs acceptable. The manipulations of physical therapists are known to be very efficient clinically but they are mostly empirical since the biophysical mechanisms involved in these manipulations have never been studied. We develop in this work a model of mucus clearance in idealized rigid human bronchial trees and focus our study on the interaction between (1) tree geometry, (2) mucus physical properties and (3) amplitude of flow rate in the tree. The mucus is considered as a Bingham fluid (gel-like) which is moved upward in the tree thanks to its viscous interaction with air flow. Our studies point out the important roles played both by the geometry and by the physical properties of mucus (yield stress and viscosity). More particularly, the yield stress has to be overcome to make mucus flow. Air flow rate and yield stress determine the maximal possible mucus thickness in each branch of the tree at equilibrium. This forms a specific distribution of mucus in the tree whose characteristics are strongly related to the multi-scaled structure of the tree. The behavior of any mucus distribution is then dependent on this distribution. Finally, our results indicate that increasing air flow rates ought to be more efficient to drain mucus out of the bronchial tree while minimizing patient discomfort

  9. Carbon dioxide emissions and nutrition on a drained pine mire - a case study

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, M; Karsisto, M; Kaunisto, S [Finnish Forest Research Inst., Vantaa (Finland). Vantaa Research Centre

    1997-12-31

    Drainage of boreal peatlands intensify aerobic decomposition and carbon dioxide emission from the peat substrate and increase tree growth. CO{sub 2} emission rates depend on the ground water level and the soil temperature. Predicted rises in mean air temperatures due to anthropogenically induced climate change are expected to further increase carbon dioxide emission from drained boreal peatlands. The role of added nutrients is somewhat vague. The purpose of this presentation is to give some preliminary results on microbial biomass carbon and on carbon dioxide output/input relationship on a pine mire. (6 refs.)

  10. Carbon dioxide emissions and nutrition on a drained pine mire - a case study

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, M.; Karsisto, M.; Kaunisto, S. [Finnish Forest Research Inst., Vantaa (Finland). Vantaa Research Centre

    1996-12-31

    Drainage of boreal peatlands intensify aerobic decomposition and carbon dioxide emission from the peat substrate and increase tree growth. CO{sub 2} emission rates depend on the ground water level and the soil temperature. Predicted rises in mean air temperatures due to anthropogenically induced climate change are expected to further increase carbon dioxide emission from drained boreal peatlands. The role of added nutrients is somewhat vague. The purpose of this presentation is to give some preliminary results on microbial biomass carbon and on carbon dioxide output/input relationship on a pine mire. (6 refs.)

  11. Total selenium in irrigation drain inflows to the Salton Sea, California, April 2009

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Saiki, Michael K.; Brumbaugh, William G.

    2009-01-01

    This report presents the results for the final sampling period (April 2009) of a 4-year monitoring program to characterize selenium concentrations in selected irrigation drains flowing into the Salton Sea, California. Total selenium and total suspended solids were determined in water samples. Total selenium, percent total organic carbon, and particle size were determined in sediments. Mean total selenium concentrations in water ranged from 0.98 to 22.9 micrograms per liter. Total selenium concentrations in sediment ranged from 0.078 to 5.0 micrograms per gram dry weight.

  12. Intracavitary application of contrast medium in the follow-up of complicated tube-drained pleural empyema: Conventional radiography vs CT

    International Nuclear Information System (INIS)

    Duex, M.; Bischoff, H.; Schmaehl, A.; Tuengerthal, S.

    1997-01-01

    Purpose: To define the value of conventional radiography compared with CT in the follow-up of complicated, long-term tube drained pleural empyema after intracavitary application of contrast medium. Methods: 28 patients with complicated pleural empyema (stage III) and longterm tube drainage were submitted to fluoroscopy of the pleural cavity and a CT of the thorax after contrast medium had been instilled into the pleural space. Both examinations were judged by the following criteria: Number and morphology of pleural cavities, quality of drainage and accompanying thoracic disease. Results: 49 pleural cavities were diagnosed. Judgement of drainage corresponded in 79% of cases and differed 21% with proof of further not drained cavities only on CT. 4 bronchopleural fistulas were diagnosed by fluoroscopy, of which only 2 were evident on CT. Accompanying thoracic disease was reliably detected by CT only. Conclusions: Diagnosis of bronchopleural fistulas and judgement of the pleural drainage is best possible using fluoroscopy after application of contrast medium into the pleural space. CT is most accurate to detect further cavities that have not been drained, to look for concomitant thoracic disease, and to judge the morphology of the pleural cavity. Conventional radiography of the pleural space is effective and recommended to be used as a first line investigation for the follow-up of stage III empyemas. Patients in poor general condition (fever, elevated blood markers indicating inflammation) should be examined by both fluoroscopy and CT. (orig.) [de

  13. Characteristics of dissolved organic matter in the Upper Klamath River, Lost River, and Klamath Straits Drain, Oregon and California

    Science.gov (United States)

    Goldman, Jami H.; Sullivan, Annett B.

    2017-12-11

    Concentrations of particulate organic carbon (POC) and dissolved organic carbon (DOC), which together comprise total organic carbon, were measured in this reconnaissance study at sampling sites in the Upper Klamath River, Lost River, and Klamath Straits Drain in 2013–16. Optical absorbance and fluorescence properties of dissolved organic matter (DOM), which contains DOC, also were analyzed. Parallel factor analysis was used to decompose the optical fluorescence data into five key components for all samples. Principal component analysis (PCA) was used to investigate differences in DOM source and processing among sites.At all sites in this study, average DOC concentrations were higher than average POC concentrations. The highest DOC concentrations were at sites in the Klamath Straits Drain and at Pump Plant D. Evaluation of optical properties indicated that Klamath Straits Drain DOM had a refractory, terrestrial source, likely extracted from the interaction of this water with wetland peats and irrigated soils. Pump Plant D DOM exhibited more labile characteristics, which could, for instance, indicate contributions from algal or microbial exudates. The samples from Klamath River also had more microbial or algal derived material, as indicated by PCA analysis of the optical properties. Most sites, except Pump Plant D, showed a linear relation between fluorescent dissolved organic matter (fDOM) and DOC concentration, indicating these measurements are highly correlated (R2=0.84), and thus a continuous fDOM probe could be used to estimate DOC loads from these sites.

  14. Verifiable metamodels for nitrate losses to drains and groundwater in the Corn Belt, USA

    Science.gov (United States)

    Nolan, Bernard T.; Malone, Robert W.; Gronberg, Jo Ann M.; Thorp, K.R.; Ma, Liwang

    2012-01-01

    Nitrate leaching in the unsaturated zone poses a risk to groundwater, whereas nitrate in tile drainage is conveyed directly to streams. We developed metamodels (MMs) consisting of artificial neural networks to simplify and upscale mechanistic fate and transport models for prediction of nitrate losses by drains and leaching in the Corn Belt, USA. The two final MMs predicted nitrate concentration and flux, respectively, in the shallow subsurface. Because each MM considered both tile drainage and leaching, they represent an integrated approach to vulnerability assessment. The MMs used readily available data comprising farm fertilizer nitrogen (N), weather data, and soil properties as inputs; therefore, they were well suited for regional extrapolation. The MMs effectively related the outputs of the underlying mechanistic model (Root Zone Water Quality Model) to the inputs (R2 = 0.986 for the nitrate concentration MM). Predicted nitrate concentration was compared with measured nitrate in 38 samples of recently recharged groundwater, yielding a Pearson’s r of 0.466 (p = 0.003). Predicted nitrate generally was higher than that measured in groundwater, possibly as a result of the time-lag for modern recharge to reach well screens, denitrification in groundwater, or interception of recharge by tile drains. In a qualitative comparison, predicted nitrate concentration also compared favorably with results from a previous regression model that predicted total N in streams.

  15. Investigation of radioactive contamination at non-radioactive drains of the Tsuruga Nuclear Power Station

    International Nuclear Information System (INIS)

    Koide, Hiroaki; Imanaka, Tetsuji; Ebisawa, Toru; Kawano, Shinji; Kobayashi, Keiji.

    1982-05-01

    In April, 1981, it was disclosed that a drainage area at the Tsuruga Nuclear Power Station was so much contaminated with radioactivites. Although Ministry of International Trade and Industry (MITI) officially provided an explanation of a process that resulted in the contamination, many problems remain unsolved on account of insufficient and limited investigations. The authors collected mud samples from contaminated manholes and examined radioactivities in them through the measurement of #betta#- and #betta#-spectra. Chemical separation of the samples was carried out in order to obtain precise concentration of radioactive cesium. Results are as follows: i) the concentration of radioactivities does not show monotonous decrease along the stream line but an anomalous peak at downstream manholes, ii) at the manhole specified No. 6 located rather downstream, 137 Cs concentration is significantly high and the composition of radioactive nuclides is quite different from that in the other manholes, and iii) additional radioactive contamination was observed in other manholes of non-radioactive drains which would not be influenced by the accident explained by MITI. Our present work has provided much more data than by MITI and made it clear that the overall data cnnot be consistent with the simple MITI explanation; a single radioactive release accident caused the disclosed contamination. It is concluded that non-radioactive water drains at the Tsuruga Nuclear Power Station had been under continual contamination. (author)

  16. A low specific on-resistance SOI MOSFET with dual gates and a recessed drain

    International Nuclear Information System (INIS)

    Luo Xiao-Rong; Hu Gang-Yi; Zhang Zheng-Yuan; Luo Yin-Chun; Fan Ye; Wang Xiao-Wei; Fan Yuan-Hang; Cai Jin-Yong; Wang Pei; Zhou Kun

    2013-01-01

    A low specific on-resistance (R on,sp ) integrable silicon-on-insulator (SOI) metal-oxide semiconductor field-effect transistor (MOSFET) is proposed and investigated by simulation. The MOSFET features a recessed drain as well as dual gates, which consist of a planar gate and a trench gate extended to the buried oxide layer (BOX) (DGRD MOSFET). First, the dual gates form dual conduction channels, and the extended trench gate also acts as a field plate to improve the electric field distribution. Second, the combination of the trench gate and the recessed drain widens the vertical conduction area and shortens the current path. Third, the P-type top layer not only enhances the drift doping concentration but also modulates the surface electric field distributions. All of these sharply reduce R on,sp and maintain a high breakdown voltage (BV). The BV of 233 V and R on,sp of 4.151 mΩ·cm 2 (V GS = 15 V) are obtained for the DGRD MOSFET with 15-μm half-cell pitch. Compared with the trench gate SOI MOSFET and the conventional MOSFET, R on,sp of the DGRD MOSFET decreases by 36% and 33% with the same BV, respectively. The trench gate extended to the BOX synchronously acts as a dielectric isolation trench, simplifying the fabrication processes. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  17. The Validation of a No-Drain Policy After Thoracoscopic Major Lung Resection.

    Science.gov (United States)

    Murakami, Junichi; Ueda, Kazuhiro; Tanaka, Toshiki; Kobayashi, Taiga; Kunihiro, Yoshie; Hamano, Kimikazu

    2017-09-01

    The omission of postoperative chest tube drainage may contribute to early recovery after thoracoscopic major lung resection; however, a validation study is necessary before the dissemination of a selective drain policy. A total of 162 patients who underwent thoracoscopic anatomical lung resection for lung tumors were enrolled in this study. Alveolar air leaks were sealed with a combination of bioabsorbable mesh and fibrin glue. The chest tube was removed just after the removal of the tracheal tube in selected patients in whom complete pneumostasis was obtained. Alveolar air leaks were identified in 112 (69%) of the 162 patients in an intraoperative water-seal test performed just after anatomical lung resection. The chest tube could be removed in the operating room in 102 (63%) of the 162 patients. There were no cases of 30-day postoperative mortality or in-hospital death. None of the 102 patients who did not undergo postoperative chest tube placement required redrainage for a subsequent air leak or subcutaneous emphysema. The mean length of postoperative hospitalization was shorter in patients who had not undergone postoperative chest tube placement than in those who had. The omission of chest tube placement was associated with a reduction in the visual analog scale for pain from postoperative day 0 until postoperative day 3, in comparison with patients who underwent chest tube placement. The outcome of our validation cohort revealed that a no-drain policy is safe in selected patients undergoing thoracoscopic major lung resection and that it may contribute to an early recovery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Experimental demonstration on the ultra-low source/drain resistance by metal-insulator-semiconductor contact structure in In0.53Ga0.47As field-effect transistors

    Directory of Open Access Journals (Sweden)

    M.-H. Liao

    2013-09-01

    Full Text Available In this work, we demonstrate the ultra-low contact resistivity of 6.7 × 10−9 Ω/cm2 by inserting 0.6-nm-ZnO between Al and InGaAs(Si: 1.5 × 1019 cm−3. The metal-insulator-semiconductor tunneling diode with 0.6-nm-ZnO exhibits nearly zero (0.03 eV barrier height. We apply this contact structure on the source/drain of implant-free In0.53Ga0.47As quantum-well metal-oxide-semiconductor field- effect transistors. The excellent on-state performance such as saturation drain current of 3 × 10−4 A/μm and peak transconductance of 1250 μS/μm is obtained which is attributed to the ultra-low source/drain resistance of 190 Ω-μm.

  19. Runoff Responses to Forest Thinning at Plot and Catchment Scales in a Headwater Catchment Draining Japanese Cypress Forest

    Science.gov (United States)

    We examined the effect of forest thinning on runoff generation at plot and catchment scales in headwater basins draining a Japanese cypress (Chamaecyparis obtusa) forest. We removed 58.3% of the stems (corresponding to 43.2% of the basal area) in the treated headwater basin (catc...

  20. Triaxial slide-hold-slide shear experiment of sedimentary rock under drain condition

    International Nuclear Information System (INIS)

    Kishida, Kiyoshi; Yano, Takao; Elsworth, Derek; Yasuhara, Hideaki; Nakashima, Shinichiro

    2011-01-01

    When discussing the mechanical and hydro-mechanical properties of rock masses under the long-term holding, the variation of rock structure and the change of shear band condition should be discussed in considering the effect of thermal and chemical influences. In this research, the triaxial shear experiment under drain condition was conducted through sedimentary rock, and in the residual stress state, the slide-hold-slide processes were applied to these triaxial experiments. The experiments were carried out in 3 kinds of confining conditions and 2 kinds of thermal conditions. Consequently, the healing phenomena can be observed and the shear strength recovery is also confirmed in process of the holding time. (author)

  1. Nuclear power plant laundry drain treatment using membrane bio reactor

    International Nuclear Information System (INIS)

    Tsukamoto, Masaaki; Kohanawa, Osamu; Kinugasa, Atsushi; Ogawa, Naoki; Murogaki, Kenta

    2012-01-01

    In nuclear power plant, the radioactive effluent generated by washing the clothes worn in controlled area and the hand and shower water used at the controlled area are treated in laundry drain treatment system. Although various systems which treat such liquid waste preexist, the traditional treatment system has disadvantages such as high running cost and a large amount of secondary waste generation. To solve these matters, we have considered application of an activated sludge system, membrane bio reactor, which has been practically used in general industry. For nuclear power plant, the activated sludge system has been developed, tested in its adaptability and the adequacy has been proved. Some preexisting treatment systems have been replaced with this activated sludge system for the first time in a domestic nuclear power plant, and the renewal system is now in operation. The result is reported. (author)

  2. Analytical drain current formulation for gate dielectric engineered dual material gate-gate all around-tunneling field effect transistor

    Science.gov (United States)

    Madan, Jaya; Gupta, R. S.; Chaujar, Rishu

    2015-09-01

    In this work, an analytical drain current model for gate dielectric engineered (hetero dielectric)-dual material gate-gate all around tunnel field effect transistor (HD-DMG-GAA-TFET) has been developed. Parabolic approximation has been used to solve the two-dimensional (2D) Poisson equation with appropriate boundary conditions and continuity equations to evaluate analytical expressions for surface potential, electric field, tunneling barrier width and drain current. Further, the analog performance of the device is studied for three high-k dielectrics (Si3N4, HfO2, and ZrO2), and it has been investigated that the problem of lower ION, can be overcome by using the hetero-gate architecture. Moreover, the impact of scaling the gate oxide thickness and bias variations has also been studied. The HD-DMG-GAA-TFET shows an enhanced ION of the order of 10-4 A. The effectiveness of the proposed model is validated by comparing it with ATLAS device simulations.

  3. Carbon and Water Fluxes in a Drained Coastal Clearcut and a Pine Plantation in Eastern North Carolina

    Science.gov (United States)

    J. L. Deforest; Ge Sun; A. Noormets; J. Chen; Steve McNulty; M. Gavazzi; Devendra M. Amatya; R. W. Skaggs

    2006-01-01

    The effects of clear-cutting and cultivating for timber on ecosystem carbon and water fluxes were evaluated by comparative measurements of two drained coastal wetland systems in the North Carolina coastal plain. Measurements were conducted from January through September, 2005 in a recent clearcut (CC) of native hardwoods and a loblolly pine (Pinus tacda...

  4. Percutaneous trans-papillary elimination of common bile duct stones using an existing gallbladder drain for access.

    Science.gov (United States)

    Atar, Eli; Neiman, Chaim; Ram, Eduard; Almog, Mazal; Gadiel, Itai; Belenky, Alexander

    2012-06-01

    The presence of stones in the common bile duct (CBD) may cause complications such as obstructing jaundice or ascending cholangitis, and the stones should be removed. To assess the efficacy of percutaneous elimination of CBD stones from the gallbladder through the papilla. During a 4 year period, six patients (five men and one woman, mean age 71.5 years) who had CBD stones and an existing gallbladder drain underwent percutaneous stone push into the duodenum after balloon dilatation of the papilla, with a diameter equal to that of the largest stone. Access into the CBD was from the gallbladder, using an already existing percutaneous gallbladder drain (cholecystostomy tube). Each patient had one to three CBD stones measuring 7-14 mm. Successful CBD stone elimination into the duodenum was achieved in five of the six patients. The single failure occurred in a patient with choledochal diverticulum, who was operated successfully. There were no major or minor complications during or after the procedures. Trans-cholecystic CBD stone elimination is a safe and feasible percutaneous technique that utilizes existing tracts, thus obviating the need to create new percutaneous access. This procedure can replace endoscopic or surgical CBD exploration.

  5. A novel transanal tube designed to prevent anastomotic leakage after rectal cancer surgery: the WING DRAIN.

    Science.gov (United States)

    Nishigori, Hideaki; Ito, Masaaki; Nishizawa, Yuji

    2017-04-01

    We introduce a novel transanal tube (TAT), named the "WING DRAIN", designed to prevent anastomotic leakage after rectal cancer surgery, and report the fundamental experiments that led to its development. We performed the basic experiments to evaluate the effect of TATs on intestinal decompression, the changes they make in patterns of watery fluid drainage, the changes in their decompression effect when the extension tube connecting the TAT to the collection bag fills with watery drainage fluid, and the variations in intestinal contact and crushing pressure made by some types of TAT. Any type of TAT contributed to decompression in the intestinal tract. Watery drainage commenced from when the water level first rose to the hole in the tip of drain. The intestinal pressure increased with the length of the vertical twist in an extension tube. The crushing pressures of most types of TAT were high enough to cause injury to the intestine. We resolved the problems using an existing TAT for the purpose of intestinal decompression and by creating the first specialized TAT designed to prevent anastomotic leakage after rectal cancer surgery in Japan.

  6. Enhanced performance of a-IGZO thin-film transistors by forming AZO/IGZO heterojunction source/drain contacts

    International Nuclear Information System (INIS)

    Zou, Xiao; Fang, Guojia; Wan, Jiawei; Liu, Nishuang; Long, Hao; Wang, Haolin; Zhao, Xingzhong

    2011-01-01

    A low-cost Al-doped ZnO (AZO) thin film was deposited by radio-frequency magnetron sputtering with different Ar/O 2 flow ratios. The optical and electrical properties of an AZO film were investigated. A highly conductive AZO film was inserted between the amorphous InGaZnO (a-IGZO) channel and the metal Al electrode to form a heterojunction source/drain contact, and bottom-gate amorphous a-IGZO thin-film transistors (TFTs) with a high κ HfON gate dielectric were fabricated. The AZO film reduced the source/drain contact resistivity down to 79 Ω cm. Enhanced device performance of a-IGZO TFT with Al/AZO bi-layer S/D electrodes (W/L = 500/40 µm) was achieved with a saturation mobility of 13.7 cm 2 V −1 s −1 , a threshold voltage of 0.6 V, an on-off current ratio of 4.7 × 10 6 , and a subthreshold gate voltage swing of 0.25 V dec −1 . It demonstrated the potential application of the AZO film as a promising S/D contact material for the fabrication of the high performance TFTs

  7. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety.

    Science.gov (United States)

    Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj

    2015-01-01

    Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.

  8. Cleanup Verification Package for the 118-H-6:2, 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils; the 118-H-6:3, 105-H Reactor Fuel Storage Basin and Underlying Soils; the 118-H-6:6 Fuel Storage Basin Deep Zone Side Slope Soils; the 100-H-9, 100-H-10, and 100-H-13 French Drains; the 100-H-11 and 100-H-12 Expansion Box French Drains; and the 100-H-14 and 100-H-31 Surface Contamination Zones

    International Nuclear Information System (INIS)

    Appel, M.J.

    2006-01-01

    This cleanup verification package documents completion of removal actions for the 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils (subsite 118-H-6:2); 105-H Reactor Fuel Storage Basin and Underlying Soils (118-H-6:3); and Fuel Storage Basin Deep Zone Side Slope Soils. This CVP also documents remedial actions for the following seven additional waste sties: French Drain C (100-H-9), French Drain D (100-H-10), Expansion Box French Drain E (100-H-11), Expansion Box French Drain F (100-H-12), French Drain G (100-H-13), Surface Contamination Zone H (100-H-14), and the Polychlorinated Biphenyl Surface Contamination Zone (100-H-31)

  9. Migração internacional de trabalho qualificado e o fenômeno do brain drain no Brasil

    OpenAIRE

    FARIA, Bruna Maia de

    2008-01-01

    Maia de Faria, Bruna; Barrantes Hidalgo, Álvaro. Migração internacional de trabalho qualificado e o fenômeno do brain drain no Brasil. 2008. Dissertação (Mestrado). Programa de Pós-Graduação em Economia, Universidade Federal de Pernambuco, Recife, 2008.

  10. Phosphorus and greenhouse gas dynamics in a drained calcareous wetland soil in Minnesota.

    Science.gov (United States)

    Berryman, Erin M; Venterea, Rodney T; Baker, John M; Bloom, Paul R; Elf, Brandy

    2009-01-01

    Restoration of wetland hydrology can produce ecological benefits but may have unintended consequences. We examined effects of altered water level on release of dissolved reactive phosphorus (DRP) and greenhouse gases (GHG) in soil cores from a marsh being evaluated for restoration. We also measured field concentrations of DRP and other constituents in wetland porewater. Intact cores from a sampling location with higher Fe and lower calcium carbonate (CaCO(3)) contents released more DRP than another location, and displayed higher DRP under completely saturated compared to partly drained conditions. Porewater samples collected from the high-Fe location also contained higher DRP levels. Chemical data suggest that redox-driven reactions largely controlled DRP levels at the high-Fe site, while CaCO(3) adsorption was more important at the low-Fe site. Over the long term, water table elevation may attenuate P draining from the wetland due to decreased mineralization. However, such measures may increase P release in the short term. Raising the water level in soil cores resulted in decreased nitrous oxide (N(2)O) emissions, increased methane (CH(4)) emissions, and an overall increase in total global warming potential (GWP). The proportion of total GWP contributed by N(2)O decreased from 14% to < or = 1% as water level was raised, while the proportion contributed by CH(4) increased from 10 to 20% to 60 to 80%. Restoration of hydrology in the Rice Lake wetland has the potential to affect both local water quality and global air quality. These combined effects complicate the cost-to-benefit analysis of such wetland restoration efforts.

  11. Liquefaction under drained condition, from the lab to reality ?

    Science.gov (United States)

    Clément, Cécile; Aharonov, Einat; Stojanova, Menka; Toussaint, Renaud

    2015-04-01

    Liquefaction constitutes a significant natural hazard in relation to earthquakes and landslides. This effect can cause buildings to tilt or sink into the soil, mud-volcanoes, floatation of buried objects, long-runout landslides, etc. In this work we present a new understanding regarding the mechanism by which buildings sink and tilt during liquefaction caused by earthquakes. Conventional understanding of liquefaction explains most observed cases as occurring in an undrained, under-compacted, layer of sandy soil saturated with water [1]: According to that understanding, the under compacted sandy layer has the tendency to compact when a load is applied. In our case the load comes from ground shaking during an earthquake. When the soil compacts, the fluid pore pressure rises. Because in undrained conditions the fluid cannot flow out, the pore pressure builds up. The weight of buildings is in this case transferred from the grains of the soil to the pore water. The soil loses its rigidity and it flows like a liquid. From this model scientists made theoretical and empirical laws for geotechnical use and buildings construction. Despite the success of this conventional model in many cases, liquefied soils were also observed under drained conditions, and in previously compacted soils, which doesn't agree with the assumption of the model quoted above. One of the famous liquefaction events is the Kobe port destruction during the 1995 earthquake. A simple calculation of the Deborah number following Goren et al ([2][3]) shows that the undrained constraint was not met below the Kobe port during the 1995 earthquake. We propose another model, of liquefaction in drained granular media. According to our model the mere presence of water in granular media is enough to cause liquefaction during an earthquake, provided that the water reaches close to the surface. Our computations are based on the buoyancy force, and we take into account the static fluid pressure only. For small

  12. Fluvial sediment inputs to upland gravel bed rivers draining forested catchments: potential ecological impacts

    Directory of Open Access Journals (Sweden)

    S. D. Marks

    1997-01-01

    Full Text Available As identified by the detailed long-term monitoring networks at Plynlimon, increased sediment supply to upland fluvial systems is often associated with forestry land-use and practice. Literature is reviewed, in the light of recent results from Plynlimon sediment studies, to enable identification of the potential ecological impacts of fluvial particulate inputs to upland gravel bed rivers draining forested catchments similar to the headwaters of the River Severn. Both sediment transport and deposition can have significant impacts upon aquatic vertebrates, invertebrates and plants.

  13. Dynamic Looping of a Free-Draining Polymer

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Felix X. -F.; Stinis, Panos; Qian, Hong

    2018-01-11

    Here, we revisit the celebrated Wilemski--Fixman (WF) treatment for the looping time of a free-draining polymer. The WF theory introduces a sink term into the Fokker--Planck equation for the $3(N+1)$-dimensional Ornstein--Uhlenbeck process of polymer dynamics, which accounts for the appropriate boundary condition due to the formation of a loop. The assumption for WF theory is considerably relaxed. A perturbation method approach is developed that justifies and generalizes the previous results using either a delta sink or a Heaviside sink. For both types of sinks, we show that under the condition of a small dimensionless $\\epsilon$, the ratio of capture radius to the Kuhn length, we are able to systematically produce all known analytical and asymptotic results obtained by other methods. This includes most notably the transition regime between the $N^2$ scaling of Doi, and $N\\sqrt{N}/\\epsilon$ scaling of Szabo, Schulten, and Schulten. The mathematical issue at play is the nonuniform convergence of $\\epsilon\\to 0$ and $N\\to\\infty$, the latter being an inherent part of the theory of a Gaussian polymer. Our analysis yields a novel term in the analytical expression for the looping time with small $\\epsilon$, which was previously unknown. Monte Carlo numerical simulations corroborate the analytical findings. The systematic method developed here can be applied to other systems modeled by multidimensional Smoluchowski equations.

  14. Filling, storing and draining. Three key aspects of landslide hydrology

    Science.gov (United States)

    Bogaard, Thom; Greco, Roberto

    2016-04-01

    Rainfall-triggered landslides are among the most widespread hazards in the world. The hydrology in and around a landslide area is key to pore pressure build-up in the soil skeleton which reduces shear strength due to the buoyancy force exerted by water in a saturated soil and to soil suction in an unsaturated soil. Extraordinary precipitation events trigger most of the landslides, but, at the same time, the vast majority of slopes do not fail. The intriguing question is: 'When and where exactly can a slope become triggered to slide and flow downwards?' The objective of this article is to present and discuss landslide hydrology at three scales - pore, hillslope, and catchment - which, taken together, give an overview of this interdisciplinary science. In fact, for rainfall-triggered landslides to occur, an unfavourable hydrological interplay should exist between fast and/or prolonged infiltration, and a relatively 'slow' drainage. The competition of water storage, pressure build-up and the subsequently induced drainage contains the importance of the timing, which is indisputably one of the more delicate but relevant aspects of landslide modelling, the overlay of hydrological processes with different time scales. As slopes generally remain stable, we can argue that effective drainage mechanisms spontaneously develop, as the best for a slope to stay stable is getting rid of the overload of water (above field capacity), either vertically or laterally. So, landslide hydrology could be framed as 'Filling-Storing-Draining'. Obviously, 'Storing' is added to stress the importance of dynamic pressure build-up for slope stability. 'Draining' includes all removal of water from the system (vertical and lateral flow, evaporation and transpiration) and thus pore water pressure release. Furthermore, by addressing landslide hydrology from both earth sciences and soil mechanics perspectives, we aim to manifest the hydrological processes in hillslopes and their influence on behaviour

  15. Return of talent programs: rationale and evaluation criteria for programs to ameliorate a 'brain drain'.

    Science.gov (United States)

    Keely, C B

    1986-03-01

    The term, brain drain, describes the loss of skilled professionals and the nonreturn of students from advanced study abroad. It is now used almost exclusively in reference to mobility from less developed countries to more developed countries. Controversy centers on whether needed skills are being drawn off unfairly at subsidized rates from developing to developed countries or whether excess capability is being utilized in developed countries rather than underemployed or wasted at home. Some causes of high level personnel migration include: 1) wage differentials between sending and receiving countries; 2) absence of opportunities for career development or mobility for reasons other than merit or accomplishment; 3) lack of high quality facilities, equipment, time, and other costly supports in developing countries; 4) employer's lack of knowledge of employee work and the resulting wages; and 5) political disagreement or persecution. Prospects for closing wage gaps and upgrading working conditions on a large scale in developing countries are dim. Growth of the labor force coupled with national needs that are not congruent with professions requiring costly facilities, supplies, and equipment make this a slim possibility. Increasing career mobility possibilities seems to be a more promising route to reducing brain drain. One form of preventive measure is offering study abroad which requires service at the end of the study period; a variation is to guarantee employment for university graduates or for certain sectors, such as scientists. Restructuring decisions on hiring and promotion would have a positive effect, as would developing a better evaluation of expected productivity by type of training. Successful return of talent programs will be relatively modest in terms of the number of people returning and should be thought of as a part of human capital investment. Programs that are concerned with filling positions rather than with luring talent home are more likely to be

  16. Do Foley Catheters Adequately Drain the Bladder? Evidence from CT Imaging Studies

    Directory of Open Access Journals (Sweden)

    Svetlana Avulova

    2015-06-01

    Full Text Available ABSTRACTIntroduction:The Foley catheter has been widely assumed to be an effective means of draining the bladder. However, recent studies have brought into question its efficacy. The objective of our study is to further assess the adequacy of Foley catheter for complete drainage of the bladder.Materials and Methods:Consecutive catheterized patients were identified from a retrospective review of contrast enhanced and non-contrast enhanced computed tomo-graphic (CT abdomen and pelvis studies completed from 7/1/2011-6/30/2012. Residual urine volume (RUV was measured using 5mm axial CT sections as follows: The length (L and width (W of the bladder in the section with the greatest cross sectional area was combined with bladder height (H as determined by multiplanar reformatted images in order to calculate RUV by applying the formula for the volume (V of a sphere in a cube: V=(ϖ/6*(L*W*H.Results:RUVs of 167 (mean age 67 consecutively catheterized men (n=72 and women (n=95 identified by CT abdomen and pelvis studies were calculated. The mean RUV was 13.2 mL (range: 0.0 mL-859.1 mL, standard deviation: 75.9 mL, margin of error at 95% confidence:11.6 mL. Four (2.4% catheterized patients had RUVs of >50 mL, two of whom had an improperly placed catheter tip noted on their CT-reports.Conclusions:Previous studies have shown that up to 43% of catheterized patients had a RUV greater than 50 mL, suggesting inadequacy of bladder drainage via the Foley catheter. Our study indicated that the vast majority of patients with Foley catheters (97.6%, had adequately drained bladders with volumes of

  17. Quantity and quality of phosphorus losses from an artificially drained lowland catchment

    Science.gov (United States)

    Nausch, Monika; Woelk, Jana; Kahle, Petra; Nausch, Günther; Leipe, Thomas; Lennartz, Bernd

    2017-04-01

    Currently, agricultural diffuse sources constitute the major portion of phosphorus (P) fluxes to the Baltic Sea and have to reach the good ecological status aimed by the Baltic Sea Action Plan and the Marine Strategy Framework Directive. The objective of this study was to uncover the change in phosphorus loading as well as in P fractions along the flow path of a mid-size river basin in order to derive risk assessment and management strategies for a sustainable P reduction. P-fractions and the mineral composition of particulate P were investigated in a sub-basin of the river Warnow, the second largest German catchment discharging to the Baltic Sea. Samples were collected from the sources (tile drain, ditch) and along the subsequent brook up to the river Warnow representing spatial scales of a few hectars up to 3300 km2. The investigations were performed during the discharge season from November 1th 2013 until April 30th 2014 covering a relative dry and mild winter period. We observed an increase of total phosphorus (TP) concentrations from 15.5 ± 3.9 µg L-1 in the drain outlet to 72.0 ± 7.2 µg L-1 in the river Warnow emphasizing the importance of sediment-bound P mobilization along the flow path. Particulate phosphorus (PP) of 36.6 - 61.2% accounted for the largest share of TP in the streams. Clay minerals and Fe(hydr)oxides were the main carrier of particle bound P followed by apatite. A transformation of dissolved inorganic phosphorus (DIP) into particulate organic P was observed in the river Warnow with the beginning of the growth season in February. Our investigations indicate that the overall P load could be reduced by half when PP is removed.

  18. Do Foley catheters adequately drain the bladder? Evidence from CT imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Avulova, Svetlana; Li, Valery J.; Khusid, Johnathan A. [Department of Urology, SUNY Downstate College of Medicine, Brooklyn, NY (United States); Choi, Woo S. [Radiology, SUNY Downstate College of Medicine, Brooklyn, NY (United States); Weiss, Jeffrey P., E-mail: johnathan.khusid@downstate.edu [Department of Urology, Weill Cornell Medical College, New York, NY (United States)

    2015-05-15

    Introduction: The Foley catheter has been widely assumed to be an effective means of draining the bladder. However, recent studies have brought into question its efficacy. The objective of our study is to further assess the adequacy of Foley catheter for complete drainage of the bladder. Materials and Methods: Consecutive catheterized patients were identified from a retrospective review of contrast enhanced and non-contrast enhanced computed tomographic (CT) abdomen and pelvis studies completed from 7/1/2011-6/30/2012. Residual urine volume (RUV) was measured using 5mm axial CT sections as follows: The length (L) and width (W) of the bladder in the section with the greatest cross sectional area was combined with bladder height (H) as determined by multiplanar reformatted images in order to calculate RUV by applying the formula for the volume (V) of a sphere in a cube:V=(π/6)⁎L⁎W⁎H). Results: RUVs of 167 (mean age 67) consecutively catheterized men (n=72) and women (n=95) identified by CT abdomen and pelvis studies were calculated. The mean RUV was 13.2 mL (range: 0.0 mL-859.1 mL, standard deviation: 75.9 mL, margin of error at 95% confidence:11.6 mL). Four (2.4%) catheterized patients had RUVs of >50 mL, two of whom had an improperly placed catheter tip noted on their CT-reports. Conclusions: Previous studies have shown that up to 43% of catheterized patients had a RUV greater than 50 mL, suggesting inadequacy of bladder drainage via the Foley catheter. Our study indicated that the vast majority of patients with Foley catheters (97.6%), had adequately drained bladders with volumes of <50 mL. (author)

  19. Chemical and microbiological water quality of subsurface agricultural drains during a field trial of liquid dairy manure effluent application rate and varying tillage practices, Upper Tiffin Watershed, southeastern Michigan

    Science.gov (United States)

    Haack, Sheridan Kidd; Duris, Joseph W.

    2008-01-01

    A field trial was done in the Upper Tiffin River Watershed, in southeastern Michigan, to determine the influence of liquid dairy manure effluent (LDME) management practices on the quality of agricultural subsurface-drain water. Samples from subsurface drains were analyzed for nutrients, fecal-coliform and Escherichia coli (E. coli) bacteria, antibiotics, chemicals typically detected in wastewater, and the occurrence of genes indicating the presence of shiga-toxin-producing E. coli, or of bovine-specific Bacteroidetes bacteria. Samples were collected from November 2, 2006, to March 20, 2007, from eight subsurface drains under field plots that received no LDME and no tillage (controls) or received 4,000 or 8,000 gallons per acre (gal/acre) of LDME and either no tillage or two different types of tillage. The two types of tillage tested were (1) ground-driven, rotary, subsurface cultivation and (2) rolling-tine aeration. Samples were collected before LDME application and at 4 hours, and 1, 2, 6, 7, and 14 days post-application. Nutrient concentrations were high in subsurface-drain water throughout the field-trial period and could not be attributed to the field-trial LDME application. Of the 59 drain-water samples, including those collected before LDME application and control samples for each date, 56 had concentrations greater than the U.S. Environmental Protection Agency (USEPA), Ecoregion VI recommended surface-water criterion for total phosphorus, and all samples had concentrations greater than the recommended total nitrogen criterion. Nitrate + nitrite nitrogen concentration exceeded 20 milligrams per liter for every sample and contributed most to the total nitrogen concentrations. Substantial increases in drain-water concentrations of organic and ammonia nitrogen and total phosphorus were found for all treatments, including controls, at 14 days post-application after 0.84 inch of rainfall over 2 days. E. coli concentrations exceeded the USEPA recreational

  20. Greenhouse gas flux measurements in a forestry-drained peatland indicate a large carbon sink

    Directory of Open Access Journals (Sweden)

    A. Lohila

    2011-11-01

    Full Text Available Drainage for forestry purposes increases the depth of the oxic peat layer and leads to increased growth of shrubs and trees. Concurrently, the production and uptake of the greenhouse gases carbon dioxide (CO2, methane (CH4 and nitrous oxide (N2O change: due to the accelerated decomposition of peat in the presence of oxygen, drained peatlands are generally considered to lose peat carbon (C. We measured CO2 exchange with the eddy covariance (EC method above a drained nutrient-poor peatland forest in southern Finland for 16 months in 2004–2005. The site, classified as a dwarf-shrub pine bog, had been ditched about 35 years earlier. CH4 and N2O fluxes were measured at 2–5-week intervals with the chamber technique. Drainage had resulted in a relatively little change in the water table level, being on average 40 cm below the ground in 2005. The annual net ecosystem exchange was −870 ± 100 g CO2 m−2 yr−1 in the calendar year 2005, indicating net CO2 uptake from the atmosphere. The site was a small sink of CH4 (−0.12 g CH4 m−2 yr−1 and a small source of N2O (0.10 g N2O m−2 yr−1. Photosynthesis was detected throughout the year when the air temperature exceeded −3 °C. As the annual accumulation of C in the above and below ground tree biomass (175 ± 35 g C m−2 was significantly lower than the accumulation observed by the flux measurement (240 ± 30 g C m−2, about 65 g C m−2 yr−1 was likely to have accumulated as organic matter into the peat soil. This is a higher average accumulation rate than previously reported for natural northern peatlands, and the first time C accumulation has been shown by EC measurements to occur in a forestry-drained peatland. Our results suggest that forestry