WorldWideScience

Sample records for drainage sanitary

  1. [The sanitary and hygienic state of solid garbage burial grounds in the stages of a life cycle].

    Science.gov (United States)

    Zomarev, A M; Vaĭsman, Ia I; Zaĭtseva, T A; Glushankova, I S

    2010-01-01

    The purpose of the study was to assess the sanitary-and-hygienic state of solid garbage (SG) burial grounds in the Perm Territory in different stage of a life cycle. This paper presents the results of the study of deposited waste, forming dump soil, and SG ground emissions by general sanitary and sanitary-microbiological parameters and their effect on environmental objects. The performed studies of the sanitary-and-hygienic situation on some grounds of the Perm Territory suggest that there is a need for setting up a system for sanitary-and-monitoring of SG ground and for elaborating engineering, organizational, and prophylactic measures to assure the sanitary-and-hygienic safety of objects and to control the quality and quantity of waste to be buried and the currents of emissions (ground body degassing, filtrating sewage drainage and purification).

  2. A Model of Clean Water Supply and Improvement of Enviromental Sanitary Conditions in Residential Clusters in The Mekong Delta, Vietnam

    Directory of Open Access Journals (Sweden)

    Chi Nguyen Thuy Lan

    2015-12-01

    Full Text Available In accordance with Decision 99/TTg dated 9/2/1996 and Decision 173/TTg dated 6/11/2001 of the Prime Minister regarding the construction program of residential clusters (residential flood free areas, these residential areas as constructed would be fully equipped with critical infrastructures and services such as water supply and drainage works, toilets with sanitary appropriateness, etc. to ensure environmental sanitary conditions in the residential clusters. However, the actual surveys done in residential clusters in the Mekong Delta show that many arising problems must be addressed to enable the local communities to have better living conditions and ensure the sanitary conditions and environmental safety.

  3. Sanitary-epidemiologic service in Perm region: 95th anniversary (dedicated to Russian Sanitary-epidemiologic service

    Directory of Open Access Journals (Sweden)

    V.G. Kostarev

    2017-09-01

    Full Text Available The paper outlines the first stages of sanitary activities development in Perm region. We highlight the fact that it was Perm where I.I. Molessson, the first official sanitary inspector in Russia, worked. Here one of the first sanitary inspection of a whole region was performed and "Perm sanitary bulletin" was first published. It was in Perm, where the first sanitary office was established in 1890, and in 1898 the first bacteriological laboratory was organized. Bodies and institutions of Rospotrebnadzor in Perm region are known to be founded on September 15, 1922, when a Decree by Russian People's Commissars Council "On the Republic's sanitary bodies" was issued. A sanitary-hygienic faculty of Perm Medical Institute was set up in 1931 and it gave grounds for preparing qualified sanitary inspectors for state sanitary authorities. We described basic tasks which were tackled by sanitary inspectors during the Great Patriotic War and just after it. Rospotrebnadzor activities are proved to make for substantial improvements of sanitary-epidemiologic situation in the region. Currently more than 95 % of population are provided with drinking water which fully corresponds to the sanitary legislation requirements. We note constant improvements in catering objects quality and we also see that a quantity of food samples taken at such objects which don't correspond to hygienic standards remains stably low. A share of working places deviating from hygienic standards as per noise, vibration, and illumination, has reduced. Medical examinations are now available to 97.9 % of workers functioning under hazardous (dangerous working conditions. The lowest occupa-tional morbidity level over the last few years was registered in Perm region in 2016. The Service was among the first in the country to transfer to result-oriented budgeting and risk-oriented surveillance model. Organizational structure is constantly being developed; new legal, economic and organizational

  4. DEP Reported Sanitary Sewer Overflows

    Data.gov (United States)

    Montgomery County of Maryland — Sanitary sewer overflows reported to the Department of Environmental Protection by the Washington Suburban Sanitary Commission or individuals in the County. Update...

  5. Sanitary effects of fossil fuels

    International Nuclear Information System (INIS)

    Nifenecker, H.

    2006-01-01

    In this compilation are studied the sanitary effects of fossil fuels, behavioral and environmental sanitary risks. The risks in connection with the production, the transport and the distribution(casting) are also approached for the oil(petroleum), the gas and the coal. Accidents in the home are evoked. The risks due to the atmospheric pollution are seen through the components of the atmospheric pollution as well as the sanitary effects of this pollution. (N.C.)

  6. Mathematical numeric models for assessing the groundwater pollution from Sanitary landfills

    Science.gov (United States)

    Petrov, Vasil; Stoyanov, Nikolay; Sotinev, Petar

    2014-05-01

    Landfills are among the most common sources of pollution in ground water. Their widespread deployment, prolonged usage and the serious damage they cause to all of the elements of the environment are the reasons, which make the study of the problem particularly relevant. Most dangerous of all are the open dumps used until the middle of the twentieth century, from which large amounts of liquid emissions flowed freely (landfill infiltrate). In recent decades, the problem is solved by the construction of sanitary landfills in which they bury waste or solid residue from waste utilization plants. The bottom and the sides of the sanitary landfills are covered with a protective waterproof screen made of clay and polyethylene and the landfill infiltrate is led outside through a drainage system. This method of disposal severely limits any leakage of gas and liquid emissions into the environment and virtually eliminates the possibility of contamination. The main topic in the conducted hydrogeological study was a quantitative assessment of groundwater pollution and the environmental effects of re-landfilling of an old open dump into a new sanitary landfill, following the example of the municipal landfill of Asenovgrad, Bulgaria. The study includes: 1.A set of drilling, geophysical and hydrogeological field and laboratory studies on: -the definition and designation of the spatial limits of the main hydrogeological units; -identification of filtration parameters and migration characteristics of the main hydrogeological units; -clarifying the conditions for the sustentation and drainage of groundwater; -determininng the structure of the filtration field; -identifying and assessing the size and the extent of groundwater contamination from the old open dump . 2.Mathematical numeric models of migration and entry conditions of contaminants below the bottom of the landfill unit, with which the natural protection of the geological environment, the protective effect of the engineering

  7. Organization of setting-up sanitary pass-control regime and sanitary treatment of injured persons in case of radiation accidents

    International Nuclear Information System (INIS)

    Korostin, A.S.; Klochkov, V.N.; Yatsenko, V.N.

    1995-01-01

    The main aim of sanitary pass-control regime is to prevent propagation of radioactive contamination outside the area of emergency-rescue works and guarantee of sanitary treatment of all persons having radioactive contamination. The paper has studied the questions of organization of sanitary pass-control regime, arrangement of sanitary treatment of the injured persons and rendering first aid in case of radioactive contamination of wounds. 5 refs

  8. Solid Waste in Drainage Network of Rio do Meio Watershed, Florianópolis/SC

    Directory of Open Access Journals (Sweden)

    Taiana Gava

    2012-12-01

    Full Text Available The urban drainage network is among the main pollution transport load factors. Researches on the identification of solid waste transported in the drainage network have been considered the allow evaluation of its impact. In this paper we analyze the main characteristics that influences the presence of solid wastes in the drainage network of the Rio do Meio basin, Florianópolis/SC. A metal net was installed in selected river section and monitored after each rain event. The results showed about 0.27 kg/ha.year of waste are carried in the drainage network. The majority being composed of plastics and building materials. Through the analysis of the data, it was possible to verify the presence of waste in the drainage network is due to poor packaging and to the lack of sweeping in some parts of the basin. It was also found that the total precipitation is directly proportional to the appearance of solid waste. It was concluded that the lack of an integrated management between the components of sanitary system leave unnoticed simple structural measures that ultimately decrease the amount of solid waste in the drainage basin, and that could eliminate this source of pollution.

  9. Sanitary Landfill Supplemental Test Final Report

    International Nuclear Information System (INIS)

    Altman, D.J.

    1999-01-01

    This report summarizes the performance of the Sanitary Landfill Supplemental Test data, an evaluation of applicability, conclusions, recommendations, and related information for implementation of this remediation technology at the SRS Sanitary Landfill

  10. 21 CFR 1210.14 - Sanitary inspection of plants.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sanitary inspection of plants. 1210.14 Section... FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.14 Sanitary inspection of plants. The sanitary conditions of any plant handling milk or cream any part of which is to be shipped or transported into the...

  11. 9 CFR 416.4 - Sanitary operations.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Sanitary operations. 416.4 Section 416... SANITATION § 416.4 Sanitary operations. (a) All food-contact surfaces, including food-contact surfaces of... compounds, sanitizing agents, processing aids, and other chemicals used by an establishment must be safe and...

  12. [Sanitary education of workers of bakeries and pastry enterprises].

    Science.gov (United States)

    Krasil'shchikov, M I; Nemets, M G; Novikova, O V; Gavrilenko, E V; Osipova, E M; Osinova, T I

    2000-01-01

    The paper presents experience with sanitary education of workers from food industrial enterprises. The study revealed a number of disadvantages of the methodological aspect of sanitary education of these workers. A sanitary education programme has been worked out for workers engaged in food and food processing industries (production of bread, baked goods, and confectionery) and approved by the State Sanitary and Epidemiological Surveillance Department), Ministry of Health of Russia on March 1999.

  13. Pleural fluid drainage: Percutaneous catheter drainage versus surgical chest tube drainage

    International Nuclear Information System (INIS)

    Illescas, F.F.; Reinhold, C.; Atri, M.; Bret, P.M.

    1987-01-01

    Over the past 4 years, 55 cases (one transudate, 28 exudates, and 26 empymas) were drained. Surgical chest tubes alone were used in 35 drainages, percutaneous catheters alone in five drainages, and both types in 15 drainages. Percutaneous catheter drainage was successful in 12 of 20 drainages (60%). Surgical tube drainage was successful in 18 of 50 drainages (36%). The success rate for the nonempyema group was 45% with both types of drainage. For the empyema group, the success rate for percutaneous catheter drainage was 66% vs 23% for surgical tube drainage. Seven major complications occurred with surgical tube drainage, but only one major complication occurred with percutaneous catheter drainage. Radiologically guided percutaneous catheter drainage should be the procedure of choice for pleural fluid drainage. It has a higher success rate for empyemas and is associated with less complications

  14. Simulação e avaliação do desempenho hidrológico da drenagem horizontal de percolado em aterro sanitário Leachate horizontal drainage hydrologic performance evaluation and simulation in sanitary landfill

    Directory of Open Access Journals (Sweden)

    José Capelo Neto

    2005-09-01

    Full Text Available A determinação da quantidade de percolado gerado em aterros sanitários continua sendo uma tarefa difícil, principalmente no semi-árido nordestino onde predominam caracteríticas meteorológicas e geológicas bem peculiares. O programa HELP (avaliação do comportamento hidrológico em aterros sanitários, desenvolvido por Schroder et al (1984, foi utilizado na simulação de várias configurações de drenagem de fundo. Aplicou-se ao modelo, dados meteorológicos e de solos da região onde está o aterro sanitário de Caucaia (ASMOC, a qual é representativa do semi-árido nordestino. Três características da drenagem de fundo foram variadas (configuração da drenagem, inclinação de fundo e adição de uma camada drenante com alta permeabilidade com o objetivo de avaliar a altura da coluna de percolado, a quantidade de percolado infiltrado no solo e o volume coletado para tratamento. Nas trincheiras sem camada drenante, o aumento da inclinação de fundo e a alteração da configuração dos drenos tiveram pouca influência sobre as variáveis estudadas. A adição da camada drenante proporcionou uma redução significativa da altura da coluna e na infiltração de percolado no solo, mostrando que é um componente fundamental para o bom funcionamento do sistema de drenagem horizontal em aterros sanitários.Leachate quantification in sanitary landfills has always been a difficult task for designers. In the semi-arid northeast of Brazil, where meteorological and geological characteristics are very peculiar, this task becomes even more complicated. With the aid of the computer program HELP-Hydrologic Evaluation of Landfill Performance developed by Schroeder et al (1984, and using local meteorological and geological data, various scenarios were simulated altering trench bottom inclination, drainage system configurations, and adding a layer with high hydraulic conductivity. With those changes, leachate head accumulated in the waste, leachate

  15. Cold Vacuum Drying facility sanitary sewage collection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) sanitary sewage collection system. The sanitary sewage collection system provides collection and storage of effluents and raw sewage from the CVDF to support the cold vacuum drying process. This system is comprised of a sanitary sewage holding tank and pipes for collection and transport of effluents to the sanitary sewage holding tank

  16. 25 CFR 700.55 - Decent, safe, and sanitary dwelling.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Decent, safe, and sanitary dwelling. 700.55 Section 700... PROCEDURES General Policies and Instructions Definitions § 700.55 Decent, safe, and sanitary dwelling. (a) General. The term decent, safe, and sanitary dwelling means a dwelling which— (1) Meets applicable federal...

  17. 21 CFR 1210.11 - Sanitary inspection of dairy farms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sanitary inspection of dairy farms. 1210.11... UNDER THE FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.11 Sanitary inspection of dairy farms. The sanitary conditions of any dairy farm producing milk or cream to be shipped or transported into...

  18. Sanitary landfill in situ bioremediation optimization test. Final report

    International Nuclear Information System (INIS)

    1996-01-01

    This work was performed as part of a corrective action plan for the Savannah River Site Sanitary Landfill. This work was performed for the Westinghouse Savannah River Company Environmental Restoration Department as part of final implementation of a groundwater remediation system for the SRS Sanitary Landfill. Primary regulatory surveillance was provided by the South Carolina Department of Health and Environmental Control and the US Environmental Protection Agency (Region IV). The characterization, monitoring and remediation systems in the program generally consisted of a combination of innovative and baseline methods to allow comparison and evaluation. The results of these studies will be used to provide input for the full-scale groundwater remediation system for the SRS Sanitary Landfill. This report summarizes the performance of the Sanitary Landfill In Situ Optimization Test data, an evaluation of applicability, conclusions, recommendations, and related information for implementation of this remediation technology at the SRS Sanitary Landfill

  19. First district sanitary doctor of Katerynoslav

    OpenAIRE

    M.P. Chaban; Z.I. Shevtsova; V.V. Gaponov

    2017-01-01

    The life and professional activity of Vasyl Tymofiiovych Skrylnikov — a famous doctor-hygienist, scientist, and public figure have been represented. V.T. Skrylnikov contributed to the development of sanitary-prophylaxis direction in zemstvo medicine in Katerynoslav province in the second half of the 19th century; he was the first district sanitary doctor in Katerynoslav. The scientist actively studied medical features of natural agents, namely Tymofiivska clay. He successfully worked at Slovi...

  20. [Prophylactic requirements for sanitary and epidemiological surveillance in dentistry].

    Science.gov (United States)

    Kaplan, B M; Maksimenko, L V; Fedotova, N N; Gololobova, T V; Konovalov, O E

    2009-01-01

    The paper outlines the requirements for sanitary-and-epidemiological surveillance to prevent dental diseases. The investigations pose tasks to medical prevention centers to solve the problems in tooth prophylaxis, such as organizational-and-methodological, sanitary-and-educational, health-improving, and others. The sanitary-and-hygienic requirements for therapeutic-and-prophylactic dental facilities are defined. A procedure for keeping a management protocol for the prevention of tooth diseases is described.

  1. 10 CFR 20.2003 - Disposal by release into sanitary sewerage.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Disposal by release into sanitary sewerage. 20.2003... Disposal § 20.2003 Disposal by release into sanitary sewerage. (a) A licensee may discharge licensed material into sanitary sewerage if each of the following conditions is satisfied: (1) The material is...

  2. 30 CFR 71.501 - Sanitary toilet facilities; maintenance.

    Science.gov (United States)

    2010-07-01

    ... Section 71.501 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sanitary Toilet Facilities at Surface Worksites of Surface Coal Mines § 71.501 Sanitary...

  3. [To the 90th anniversary of State Sanitary Epidemiologic Service Formation in Russian Federation].

    Science.gov (United States)

    Beliaev, E N; Podunova, L G

    2012-01-01

    State Educational Institution of Higher Professional Training of the Ministry of Health Care and Social Development Foundation of Russian Sanitary Epidemiologic Service dates back to September, 15, 1922, when a Decree on Sanitary Institutions of the Republic was signed. Afterwards the institutions of Sanitary Epidemiologic Service were improved: foundation of State Sanitary Inspectorate (1933-1951), approval of new concept of the Service and intensification of State Sanitary Inspectorate (1951-1991), foundation of State Sanitary Epidemiologic Service, centralization of management and financing of the Service, formation of Sanitary Epidemiologic Legislation (1991-2004), further restructurization of Sanitary Epidemiologic Service in accordance with administrative changes in Russia (2004 until now).

  4. First district sanitary doctor of Katerynoslav

    Directory of Open Access Journals (Sweden)

    M.P. Chaban

    2017-02-01

    Full Text Available The life and professional activity of Vasyl Tymofiiovych Skrylnikov — a famous doctor-hygienist, scientist, and public figure have been represented. V.T. Skrylnikov contributed to the development of sanitary-prophylaxis direction in zemstvo medicine in Katerynoslav province in the second half of the 19th century; he was the first district sanitary doctor in Katerynoslav. The scientist actively studied medical features of natural agents, namely Tymofiivska clay. He successfully worked at Sloviansk resort, was the editor of a local newspaper. V.T. Skrylnikov is an author of many works on balneotherapy.

  5. Problems of sanitary-hygienic arrangements in case of emergency situations

    International Nuclear Information System (INIS)

    Avetisov, G.M.; Borisov, B.K.; Volkov, N.N.; Grachev, M.I.; Korostin, A.S.; Prostakishin, G.P.

    1995-01-01

    The planning and carrying out sanitary-hygienic arrangements in emergency situation are based on scientific-research, organizing-methodical and practical trends of activities including: the necessity of taking into consideration the risk of sanitary-hygienic complications as a result of emergency situation; elaboration of criteria and classification of hazards potential danger of industrial plants and territories; the establishment of system of providing sanitary-hygienic measures in emergency situation; working out prophylactic measures for prevention, localization and liquidation of sanitary-hygienic after-effects of emergency situation; development of the system of control and express-analysis of hazardous factors; elaboration of rating-methodical base and arrangements aimed at protection of health and life of people. 5 refs

  6. Sanitary effects of fossil fuels; Effets sanitaires des combustibles fossiles

    Energy Technology Data Exchange (ETDEWEB)

    Nifenecker, H. [Centre National de la Recherche Scientifique (IN2P3/CNRS), 38 - Grenoble (France)

    2006-07-01

    In this compilation are studied the sanitary effects of fossil fuels, behavioral and environmental sanitary risks. The risks in connection with the production, the transport and the distribution(casting) are also approached for the oil(petroleum), the gas and the coal. Accidents in the home are evoked. The risks due to the atmospheric pollution are seen through the components of the atmospheric pollution as well as the sanitary effects of this pollution. (N.C.)

  7. 'To preserve the skin in health': drainage, bodily control and the visual definition of healthy skin 1835-1900.

    Science.gov (United States)

    te Hennepe, Mieneke

    2014-07-01

    The concept of a healthy skin penetrated the lives of many people in late-nineteenth-century Britain. Popular writings on skin and soap advertisements are significant for pointing to the notions of the skin as a symbolic surface: a visual moral ideal. Popular health publications reveal how much contemporary understanding of skin defined and connected ideas of cleanliness and the visual ideals of the healthy body in Victorian Britain. Characterised as a 'sanitary commissioner' of the body, skin represented the organ of drainage for body and society. The importance of keeping the skin clean and purging it of waste materials such as sweat and dirt resonated in a Britain that embraced city sanitation developments, female beauty practices, racial identities and moral reform. By focusing on the popular work by British surgeon and dermatologist Erasmus Wilson (1809-84), this article offers a history of skin through the lens of the sanitary movement and developments in the struggle for control over healthy skin still in place today.

  8. Research and development of intelligent controller for high-grade sanitary ware

    Science.gov (United States)

    Bao, Kongjun; Shen, Qingping

    2013-03-01

    With the social and economic development and people's living standards improve, more and more emphasis on modern society, people improve the quality of family life, the use of intelligent controller applications in high-grade sanitary ware physiotherapy students. Analysis of high-grade sanitary ware physiotherapy common functions pointed out in the production and use of the possible risks, proposed implementation of the system hardware and matching, given the system software implementation process. High-grade sanitary ware physiotherapy intelligent controller not only to achieve elegant and beautiful, simple, physical therapy, water power, deodorant, multi-function, intelligent control, to meet the consumers, the high-end sanitary ware market, strong demand, Accelerate the enterprise product Upgrade and improve the competitiveness of enterprises.

  9. Sanitary-epidemiological audit in russia and abroad: challenges and growth prospects (analytical review

    Directory of Open Access Journals (Sweden)

    I.V. May

    2016-12-01

    Full Text Available The shaping the system of control and surveillance activities in the Russian Federation, which affects the bodies of the sanitary-epidemiological surveillance, requires the development of new forms of cooperation between authorities and legal entities, individual entrepreneurs and population. Such a form may be represented by the sanitary and epidemiological audit as an independent objective assessment of reputable third parties. The audit is intended to check the compliance with the mandatory requirements of the economic entities, performing economic or other activities. The sanitary-epidemiological audit may be associated with a system of certification for compliance with sanitary requirements and may assume the documented confirmation of the compliance issued by the authorized persons. The sanitary-epidemiological audit and the compliance certification to mandatory sanitary requirements can make an alternative to the planned supervision activities on facilities attributed to the category of low and moderate risk of harm to human health. The Russian sanitary legislation does not recognize the sanitary-epidemiological audit as a form of conformity assessment. The analysis of the international experience shows that it is necessary to consolidate the general rules and regulations of the sanitary-epidemiological audit at the legislative level and to develop a set of sublegislative documents in order to implement these norms. The crucial is a creation of the national system capable to regulate the registration and functioning of the organization having a right to conduct the audit activities in the field of hygienic safety. It is reasonable to develop the regulation on the list-register of auditors and to create a special training system for the auditors, who possess the methodology for health risk assessment. The key aspect of the successful introduction of the audit is a granting of presences to the economic entities having compliance

  10. Planning solutions of sanitary facilities in modern residential buildings

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2015-01-01

    Full Text Available In the article the short historical review on the design of sanitary rooms and their configurations is given. The main errors of the recent years, which led to the decrease in accommodation convenience because of the wrong approach from both the architect and engineers, are given. It is possible to use a small useful area for sanitary facilities, but it is connected with the lack of possibility of connecting washing and dishwashers. The author considers the options of engineering equipment placement in sanitary rooms taking into account the convenience of use, safety, and also resource-saving aspect. Various solutions on the organization of heating and ventilation are provided. The possible technical solutions allowing solving a flooding problem of the first floors in elite housing estates in case of accident are offered with the help of full waterproofing of sanitary rooms, and also the whole area of the apartment. The main attention was focused on the improvements of sanitary rooms for one-room and two-room apartments, which are the most demanded in the modern market of real estate. Layout solutions of the reduced bathrooms on the placement of the necessary equipment with choice justification are provided. The attention is paid to the layout solution for modern kitchens on order to increase their comfort by the use of special two-section sinks, and also a grinder of food waste in order to allow to lower the load of the systems of rubbish disposal of a building, by dumping the crushed garbage in an internal sewer network. Various options of evolutionary development of sanitary rooms for increasing the comfort degree are given. First of all, the development should happen in the direction of not only sanitation and hygiene, but also of the maintenance of the physical health of the people living in the building. It can be carried out by increase in a useful area of sanitary rooms, installation of exercise machines, medical bathtubs and a Jacuzzi

  11. Ants avoid superinfections by performing risk-adjusted sanitary care.

    Science.gov (United States)

    Konrad, Matthias; Pull, Christopher D; Metzler, Sina; Seif, Katharina; Naderlinger, Elisabeth; Grasse, Anna V; Cremer, Sylvia

    2018-03-13

    Being cared for when sick is a benefit of sociality that can reduce disease and improve survival of group members. However, individuals providing care risk contracting infectious diseases themselves. If they contract a low pathogen dose, they may develop low-level infections that do not cause disease but still affect host immunity by either decreasing or increasing the host's vulnerability to subsequent infections. Caring for contagious individuals can thus significantly alter the future disease susceptibility of caregivers. Using ants and their fungal pathogens as a model system, we tested if the altered disease susceptibility of experienced caregivers, in turn, affects their expression of sanitary care behavior. We found that low-level infections contracted during sanitary care had protective or neutral effects on secondary exposure to the same (homologous) pathogen but consistently caused high mortality on superinfection with a different (heterologous) pathogen. In response to this risk, the ants selectively adjusted the expression of their sanitary care. Specifically, the ants performed less grooming and more antimicrobial disinfection when caring for nestmates contaminated with heterologous pathogens compared with homologous ones. By modulating the components of sanitary care in this way the ants acquired less infectious particles of the heterologous pathogens, resulting in reduced superinfection. The performance of risk-adjusted sanitary care reveals the remarkable capacity of ants to react to changes in their disease susceptibility, according to their own infection history and to flexibly adjust collective care to individual risk.

  12. Sanitary landfill groundwater monitoring report: First quarter 1997

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.A.

    1997-05-01

    This report contains analytical data for samples taken during first quarter 1997 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site (SRS). The data are submitted in reference to the Sanitary Landfill Operating permit (DWP-087A). The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final primary Drinking Water Standards (PDWS) or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria. Wells LFW6R, LFW8R, LFW10A, LFW18, LFW21, and LFW23R were not sampled due to their proximity to the Sanitary Landfill Closure Cap activities. Wells LFW61D and LFW62D are Purge Water Containment Wells and contain mercury. These wells were not sampled since the purge water cannot be treated at the M-1 Air Stripper until the NPDES permit for the stripper is modified.

  13. Hanford 200 area (sanitary) waste water system

    International Nuclear Information System (INIS)

    Danch, D.A.; Gay, A.E.

    1994-09-01

    The US Department of Energy (DOE) Hanford Site is located in southeastern Washington State. The Hanford Site is approximately 1,450 sq. km (560 sq. mi) of semiarid land set aside for activities of the DOE. The reactor fuel processing and waste management facilities are located in the 200 Areas. Over the last 50 years at Hanford dicard of hazardous and sanitary waste water has resulted in billions of liters of waste water discharged to the ground. As part of the TPA, discharges of hazardous waste water to the ground and waters of Washington State are to be eliminated in 1995. Currently sanitary waste water from the 200 Area Plateau is handled with on-site septic tank and subsurface disposal systems, many of which were constructed in the 1940s and most do not meet current standards. Features unique to the proposed new sanitary waste water handling systems include: (1) cost effective operation of the treatment system as evaporative lagoons with state-of-the-art liner systems, and (2) routing collection lines to avoid historic contamination zones. The paper focuses on the challenges met in planning and designing the collection system

  14. Sanitary Landfill Groundwater Monitoring Report, Second Quarter 1999

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    1999-07-29

    This report contains analytical data for samples taken during Second Quarter 1999 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site. The data are submitted in reference to the Sanitary Landfill Operating Permit. The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards or screening levels, established by the US Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria.

  15. Sanitary landfill groundwater monitoring report, Third Quarter 1999

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    1999-12-08

    This report contains analytical data for samples taken during Third Quarter 1999 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site. The data are submitted in reference to the Sanitary Landfill Operating Permit. The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria.

  16. Sanitary landfill groundwater monitoring report, Third Quarter 1999

    International Nuclear Information System (INIS)

    Chase, J.

    1999-01-01

    This report contains analytical data for samples taken during Third Quarter 1999 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site. The data are submitted in reference to the Sanitary Landfill Operating Permit. The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria

  17. Sanitary landfill groundwater monitoring report. Third quarter 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    This report contains analytical data for samples taken during third quarter 1995 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site (SRS). The data are submitted in reference to the Sanitary Landfill Operating Permit (DWP-087A). The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards (PDWS) or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria.

  18. Sanitary landfill groundwater monitoring report. Third quarter 1995

    International Nuclear Information System (INIS)

    1995-11-01

    This report contains analytical data for samples taken during third quarter 1995 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site (SRS). The data are submitted in reference to the Sanitary Landfill Operating Permit (DWP-087A). The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards (PDWS) or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria

  19. Detailed test plan on co-disposal of deminumum levels of LLRW and sanitary waste

    International Nuclear Information System (INIS)

    Chian, E.S.K.

    1984-01-01

    The major objectives of this investigation are: (1) to study the attenuation mechanisms for radionuclides (LLRW) in simulated sanitary landfills with and without leachate recycle; and (2) to determine the complexation potential of ligands (viz., sulfides, humic substances) present in the leachate during different stages of landfill stabilization. Since the major emphasis of this research is on containment and isolation of LLRW within a sanitary landfill the following key elements have been incorporated into the design of the simulated pilot-scale sanitary landfills: (1) containment of LLRW within the landfills by placing the municipal refuse and LLRW in polymeric membrane-lined cells (30-mil, HDA, Gundline liner, Gundle, TX) with a leachate collection system; (2) enhancement of stabilization by leachate recycle; and (3) recovery of the gas produced from the sanitary landfills. The proposed research program addresses the fate of LLRW in municipal sanitary landfills thereby, establishing a data base to predict radionuclide pathways in sanitary landfills and to aid in assessing the environmental impacts of codisposal of LLRW within sanitary landfills. The outcome of this study may also serve to alleviate the current concern of unnecessary filling of limited space in existing licensed shallow-land burial sites. 4 figures, 1 table

  20. [Evaluation of the sanitary-and-epidemiological hazard of solid garbage in Astana].

    Science.gov (United States)

    Gumarova, Zh Zh; Bekshin, Zh M; Aushakhmetova, Z T

    2008-01-01

    According to the national plan of actions on environmental protection, industrial garbage recycling is to be introduced in Almaty and Astana for the sustainable development of the Republic of Kazakhstan. Integrated assessment of the hazard of garage is made by the sanitary-and-chemical and sanitary-and-epidemiological indices to provide the hygienic and ecological reliability of a procedure for neutralization and utilization of solid garbage (SG). According to the data obtained, Astana SG Astana in summer is characterized by the high total level of bacterial contamination. The indices of microbial contamination of SG and soil near the dustbins correlate with the density of population and the maturity of an infrastructure. Comparison of the sanitary-and-epidemiological indices of different types of SG (wastes from housing facilities, wholesale and retail outlays, and education, culture, and entertainment institutions) revealed no significant differences. According to the sanitary-and-helmintological indices, the Astana soil should be classified as pure (noninvasive). Involvement of SG into industrial recycling should be accompanied by a hygienic assessment of the hazard of waste and the reliability of used technologies in the context of warning and on-going sanitary surveillance.

  1. ‘To Preserve the Skin in Health’: Drainage, Bodily Control and the Visual Definition of Healthy Skin 1835–1900

    Science.gov (United States)

    te Hennepe, Mieneke

    2014-01-01

    The concept of a healthy skin penetrated the lives of many people in late-nineteenth-century Britain. Popular writings on skin and soap advertisements are significant for pointing to the notions of the skin as a symbolic surface: a visual moral ideal. Popular health publications reveal how much contemporary understanding of skin defined and connected ideas of cleanliness and the visual ideals of the healthy body in Victorian Britain. Characterised as a ‘sanitary commissioner’ of the body, skin represented the organ of drainage for body and society. The importance of keeping the skin clean and purging it of waste materials such as sweat and dirt resonated in a Britain that embraced city sanitation developments, female beauty practices, racial identities and moral reform. By focusing on the popular work by British surgeon and dermatologist Erasmus Wilson (1809–84), this article offers a history of skin through the lens of the sanitary movement and developments in the struggle for control over healthy skin still in place today. PMID:25045181

  2. Comparison of the sanitary effects of energy chains. Methodological aspects

    International Nuclear Information System (INIS)

    Fagnani, F.

    1979-01-01

    Beyond technical and economical matters, the development of an industrial technology involves more or less numerous indirect consequences. From this viewpoint, the author analysis the methodological problems raised in evaluating the sanitary and ecological problems of the different energy-producing lines and considers successively the matter of technical interdependences, protection and safety regulations and selection of sites, classification of risks and measuring problems in relation to sanitary effects [fr

  3. Narratives of Public Health in Dickens's Journalism: The Trouble with Sanitary Reform.

    Science.gov (United States)

    Smith, Ralph F

    2015-01-01

    Although Dickens is still known as having been a highly visible supporter of England's well-known nineteenth-century sanitary movement, he became, in fact, deeply troubled by many of this movement's fundamental tenets, as evidenced by journal narratives on fever that he edited and wrote in the mid-nineteenth century. Rather than water and sewer engineering works and a sanitary regime policed by government agencies as envisaged by Edwin Chadwick and other sanitary reformers, Dickens's view by 1855 was that only a massive erasure of the existing social and political systems and their replacement by an utterly new infrastructure would suffice.

  4. [Ways of urban sanitary and epidemiological well-being management].

    Science.gov (United States)

    Kreĭmer, M A

    2010-01-01

    The scientific rationale for preventive measures based on sanitary-and-epidemiological surveillance on environmental objects is considered. The sizes of functional zones and space for various types of communal services and amenities and leisure are regulated to ensure good urban vital activities. Multistorey housing causes an increase in the number of negative factors per area units and in their impact on health. A proposal has been made for the standardization of the ranges of urban population upsurge and size, by using the sanitary-and-hygienic rules and norms rather than climatic parameters. A criterion system for assessing the data of statistical observations has been substantiated and 5 levels of analysis and managerial decision-making have been proposed. Cause-and-effect relations may be determined for the parameters of the second level; models of program-oriented studies for the third level, only sanitary-and-epidemiological surveillance is possible for the fourth and fifth levels. The space planning scheme must provide for water supply reserves, generation areas for pure air coming into the town, and waste disposal areas. The general layout may use statistical observation parameters characterizing the second level of occurrence of negative phenomena. The statistical observation parameters characterizing the third and fourth levels of occurrence of negative phenomena may be used for municipal improvements and sanitary maintenance. These characterizing the fourth and fifth level may be used for prevention in therapeutic-and-prophylactic institutions.

  5. The SWOT Analysis of a Romanian Post-Sanitary Institution in Romania

    Directory of Open Access Journals (Sweden)

    Cristina Iorga

    2016-01-01

    Starting from a comprehensive research (literature review, the paper proposes the realization of aSWOT analysis within a post-sanitary school, which aims at emphasizing the main advantages of apost-secondary schools perceived by students and discovering major development opportunities forthe quality of services offered by it, as a premise of the improvement of the sanitary schools, andthus, the health system in Romania.

  6. Biogas of sanitary fillers

    International Nuclear Information System (INIS)

    Serrano Camacho, Ciro

    2007-01-01

    The author proposes a methodology for the preliminary estimation of the energetic potential and environmental improvement derivates of the implementation of these technologies that allows to make the first estimative of biogas generation of sanitary fillers with base in the results of the simulation of three predictive model: One Mexican, other denominated Scholl-Canyon of North American origin and the designed by the EPA. The three models use different versions and constants for a differential equation of degradation of first degree

  7. Comparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis.

    Science.gov (United States)

    Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun

    2016-08-01

    Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.

  8. Effluent and sanitary sewer monitors

    International Nuclear Information System (INIS)

    Stanchi, L.; Vasey, M.R.

    1977-03-01

    Two similar instruments that monitor the liquid wastes from the plutonium facility are described. The operation of the two instruments is completely automatic and performs a continuous surveillance in the frame of Nuclear Safeguards. One instrument controls the liquids from the facility and the other checks the sanitary sewer wastes. Both have self-diagnosing capabilities and take automatic actions in case of abnormal occurrences

  9. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... nonirritating cleansing agent shall be provided for use at each shower. (2) Sanitary flush toilet facilities. (i..., change rooms, and sanitary flush toilet facilities. 71.402 Section 71.402 Mineral Resources MINE SAFETY... Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.402 Minimum requirements for...

  10. PROPOSAL OF SANITARY MANAGEMENT OF EDIBLE ECHINODERMS IN SARDINIA

    Directory of Open Access Journals (Sweden)

    G. Terrosu

    2011-01-01

    Full Text Available Sea urchin (Paracentrotus lividus is an edible echinoderm very common in the Mediterranean sea. In the Sardinian gastronomic tradition it represents a product very used in some periods of the year, but in practice the sanitary controls by the competent authorities are very difficult. The Reg. (EC n. 853/2004 provides that, as regards as the control on production, echinoderms are assimilable to live bivalve molluscs, with the exception of the provisions on purification. In this work a proposal for the sanitary management of the phases of gathering, transport and selling of the sea urchins has been studied.

  11. [Sanitary control of food in Mexico city].

    Science.gov (United States)

    Sartí-Gutiérrez, E J; Parrilla-Cerrillo, C; Vázquez-Barojas, S; Kawashima-Hashimoto, L; Farías-Rodríguez, A; García-Juárez, C

    1989-01-01

    This work was undertaken as to avoid health risks to tourism in the "XIIth Soccer World Cup, Mexico 86". The above project was carried out through proper quality control of foods, drinking water as well as a definite care of personal hygiene of all those involved in the catering business (132 restaurants were included). The mentioned report informs only of the work of the National Public Health Laboratory in the Sanitary Epidemiological Program. The following products were analyzed: 133 water samples, 272 animated and nonliving surfaces, and 399 foods. Twenty seven percent of water samples were rejected, as well as 85% of the different surfaces and 60% of the food samples. High counts of mesophilic aerobics, followed by coliforms, S. aureus and Salmonella sp., were the principal specimens encountered. Therefore, it was suggested the permanent development of a sanitary epidemiological program.

  12. 21 CFR 129.35 - Sanitary facilities.

    Science.gov (United States)

    2010-04-01

    ... HUMAN CONSUMPTION PROCESSING AND BOTTLING OF BOTTLED DRINKING WATER Buildings and Facilities § 129.35... is not considered water of a safe, sanitary quality as required for use in bottled water by paragraph... comply with bottled water quality standards (§ 165.110(b) of this chapter) and section 402(a)(1) and (a...

  13. Methodology for the design of Santa Rosa de Cabal sanitary landfill, Risaralda

    International Nuclear Information System (INIS)

    Tabares, J; Orozco, J

    1992-01-01

    In 1987 the Regional Autonomous Corporation of Risaralda, CARDER and the Risaralda Government, they signed a cooperation agreement, in order to endowing from sanitary landfill to the municipalities of the department. In the mark of this agreement it was carried out the design of Santa Rosa's sanitary landfill, that with near 50.000 inhabitants it is constituted in the third city of the department. This city generates some 25 tons/day of garbage that at the present time are heady directly to the waters of San Eugenio River. The present work contains the most important methodological aspects in the design of the sanitary landfill and some comments about the approaches ideal Vs real approaches of selection of places

  14. Evaluation of sanitary impact of environmental pollution and quantitative evaluation of sanitary risks; Estimation de l'impact sanitaire d'une pollution environnementale et evaluation quantitative des risques sanitaires

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    The calculation of a sanitary impact present a great interest at the decision level for the decision-makers and the whole of concerned actors. It constitutes a first step to organize a social debate around the risk acceptance, to analyze the feasibility of an inquiry or an epidemiological surveillance or to proportion an activity leading to pollutants emission in natural medium. Several conclusions are brought out: it is justified to estimate a sanitary impact from a sanitary risk excess, especially coming from animal tissue. It is conceivable to go beyond an estimation of the only individual risk and to calculate a number of cases in excess in the concerned population. The working group underlines that the characteristics of the situation are the determining factor to give the type of response to bring. The effective of the population is an important element and a situation has not to be underestimated because of the size at the pretext that the excess calculation leads to a number of cases inferior to one leading to believe that the impact is minor or negligible while the individual probability is high. The sanitary impact, expressed by the number of cancer cases in excess in an exposed population is quantified from the average value of excess of sanitary risk multiplied by the population effective, and expressed with a confidence interval. The sanitary impact can be expressed under the form of a percentage of the population present in the exposure area and goes past the comparison marks usually pointed up. This practice must be cheered. An analysis of uncertainties must be made as often as possible. (N.C.)

  15. Peritoneal Drainage Versus Pleural Drainage After Pediatric Cardiac Surgery.

    Science.gov (United States)

    Gowda, Keshava Murty Narayana; Zidan, Marwan; Walters, Henry L; Delius, Ralph E; Mastropietro, Christopher W

    2014-07-01

    We aimed to determine whether infants undergoing cardiac surgery would more efficiently attain negative fluid balance postoperatively with passive peritoneal drainage as compared to traditional pleural drainage. A prospective, randomized study including children undergoing repair of tetralogy of Fallot (TOF) or atrioventricular septal defect (AVSD) was completed between September 2011 and June 2013. Patients were randomized to intraoperative placement of peritoneal catheter or right pleural tube in addition to the requisite mediastinal tube. The primary outcome measure was fluid balance at 48 hours postoperatively. Variables were compared using t tests or Fisher exact tests as appropriate. A total of 24 patients were enrolled (14 TOF and 10 AVSD), with 12 patients in each study group. Mean fluid balance at 48 hours was not significantly different between study groups, -41 ± 53 mL/kg in patients with periteonal drainage and -9 ± 40 mL/kg in patients with pleural drainage (P = .10). At 72 hours however, postoperative fluid balance was significantly more negative with peritoneal drainage, -52.4 ± 71.6 versus +2.0 ± 50.6 (P = .04). On subset analysis, fluid balance at 48 hours in patients with AVSD was more negative with peritoneal drainage as compared to pleural, -82 ± 51 versus -1 ± 38 mL/kg, respectively (P = .02). Fluid balance at 48 hours in patients with TOF was not significantly different between study groups. Passive peritoneal drainage may more effectively facilitate negative fluid balance when compared to pleural drainage after pediatric cardiac surgery, although this benefit is not likely universal but rather dependent on the patient's underlying physiology. © The Author(s) 2014.

  16. Mine drainage treatment

    OpenAIRE

    Golomeova, Mirjana; Zendelska, Afrodita; Krstev, Boris; Golomeov, Blagoj; Krstev, Aleksandar

    2012-01-01

    Water flowing from underground and surface mines and contains high concentrations of dissolved metals is called mine drainage. Mine drainage can be categorized into several basic types by their alkalinity or acidity. Sulfide rich and carbonate poor materials are expected to produce acidic drainage, and alkaline rich materials, even with significant sulfide concentrations, often produce net alkaline water. Mine drainages are dangerous because pollutants may decompose in the environment. In...

  17. Sanitary landfill energetic potential analysis: a real case study

    International Nuclear Information System (INIS)

    Desideri, Umberto; Di Maria, Francesco; Leonardi, Daniela; Proietti, Stefania

    2003-01-01

    Waste disposal represents an important problem in developed countries. Many different techniques are available to reduce the amount of waste production and its environmental impact. In most cases, sanitary landfills have been and continue to be one of the most common ways to dispose of urban and industrial wastes. It is well known how landfilling produces an important environmental drawback due to gaseous, liquid and solid emissions that are dangerous for the environment. Landfill biogas emissions contain mainly carbon dioxide and methane. In particular, the methane concentration can be higher than 50% by volume. This means that the calorific value of sanitary landfill biogas can be higher than 18,000 kJ/N m 3 . The utilization of such gas as fuel for electrical and thermal energy production can be an important way to reduce the landfill impact on the environment and represent an easy way to use a renewable energy source. In the following, the amount and composition of the biogas produced in a sanitary landfill situated in central Italy have been analysed. Experimental results have been discussed, and an energetic potential evaluation has been performed

  18. Sanitary landfill energetic potential analysis: a real case study

    Energy Technology Data Exchange (ETDEWEB)

    Desideri, Umberto E-mail: umberto.desideri@unipg.it; Di Maria, Francesco E-mail: fdm@unipg.it; Leonardi, Daniela; Proietti, Stefania

    2003-07-01

    Waste disposal represents an important problem in developed countries. Many different techniques are available to reduce the amount of waste production and its environmental impact. In most cases, sanitary landfills have been and continue to be one of the most common ways to dispose of urban and industrial wastes. It is well known how landfilling produces an important environmental drawback due to gaseous, liquid and solid emissions that are dangerous for the environment. Landfill biogas emissions contain mainly carbon dioxide and methane. In particular, the methane concentration can be higher than 50% by volume. This means that the calorific value of sanitary landfill biogas can be higher than 18,000 kJ/N m{sup 3}. The utilization of such gas as fuel for electrical and thermal energy production can be an important way to reduce the landfill impact on the environment and represent an easy way to use a renewable energy source. In the following, the amount and composition of the biogas produced in a sanitary landfill situated in central Italy have been analysed. Experimental results have been discussed, and an energetic potential evaluation has been performed.

  19. Development of Ukrainian legislation on sanitary protection of water resources in the XX century

    Directory of Open Access Journals (Sweden)

    Ю. А. Чуприна

    2015-05-01

    Full Text Available Problem Setting. The article investigates the formation in Ukraine of legal regulation of the state sanitary control of water, the process of creating of general and special jurisdiction for its implementation, as well as the regulation regime, methods and tools for health protection of waters of different categories. The relevance of this article due to the need to systematize the individual areas of water law, including the protection of water and sanitation of the twentieth century. Analysis of the recent researches and publications. The article devoted to the study of formation in Ukraine of legal regulation of the state sanitary control of water, the process of creating of general and special jurisdiction for its implementation, as well as the regulation regime, methods and tools for health protection of waters of different categories. Paper objective. The relevance of this article due to the need to identify viable methods and instruments of legal regulation of sanitary protection of water during the formation of the main areas of water legislation of Ukraine in the twentieth century. Terms used in the legal protection of water, sanitary water use rules, the bodies of sanitary supervision, the state sanitary inspection. Conclusions. Research in the field of water legislation, and therefore the individual concerned and its protection issues, many scientists were engaged as ecologists and environmentalists. However, the special historical and legal work in a range twentieth century. no. This gap makes it difficult to analyze the current state of affairs in the field of sanitary protection of water. Detection of historical stages of development of water legislation in this area, identifying the main patterns and dynamics of legal regulation of sanitary protection of water in specific historical circumstances will improve the current regime of water protection. The author analyzes the main laws and regulations in the field of materials of

  20. On professional and official requirements to physicians in radiation health by sectoral sanitary and epidemiological stations

    International Nuclear Information System (INIS)

    Usol'tsev, V.I.; Konkina, L.F.; Shishenina, V.I.

    1989-01-01

    Professional and official requirements (POR) to sanitary physician, which deals with radiation hygiene at the sanitary and epidemiologic stations (SES), are considered. These requirements determine minimum of professional skills and abilities in the field of radiation hygiene. Physician should contribute to the improvement of radiation safety and health indices for personnel and population, and in this case, his activity should not impede the further usage of ionizing radiation sources in the national economy. Sanitary physician, dealing with a actain branch of industry, concerning the problems of radiation hygiene should know the principles of deontology, aims and functions of SES establishment and departments in the field of radiation hygiene, legal principles of radiation safety is basic tasks are as follows: 1) State sanitary inspection of sanitary-hygienic measures for the environmental protection and radiation protection of population; 2) organizational and methodological activity; 3) activity in medical civil defense

  1. WATER DRAINAGE MODEL

    International Nuclear Information System (INIS)

    Case, J.B.

    2000-01-01

    The drainage of water from the emplacement drift is essential for the performance of the EBS. The unsaturated flow properties of the surrounding rock matrix and fractures determine how well the water will be naturally drained. To enhance natural drainage, it may be necessary to introduce engineered drainage features (e.g. drilled holes in the drifts), that will ensure communication of the flow into the fracture system. The purpose of the Water Drainage Model is to quantify and evaluate the capability of the drift to remove water naturally, using the selected conceptual repository design as a basis (CRWMS M andO, 1999d). The analysis will provide input to the Water Distribution and Removal Model of the EBS. The model is intended to be used to provide postclosure analysis of temperatures and drainage from the EBS. It has been determined that drainage from the EBS is a factor important to the postclosure safety case

  2. [Sanitary-hygienic assessment of microbial biofertilizer].

    Science.gov (United States)

    Arkhipchenko, N A; Akhtemava, G A; Lebedeva, T V; Voronina, A A; Makhan'kova, T I; Pavlova, M M; Shteĭntsaĭg, T A

    1991-10-01

    Biological treatment of sewage from pig-breeding complexes allowed to produce microbial biomass and primary sediments. The mixture of these components (1:1) after rendering harmless and drying out become the high effective biofertilizer. The results of chronic experiment on sanitary status of soil (microbial and helminthological indexes) under this biofertilizer usage are discussed, and the harmlessness of it is demonstrated.

  3. [Street food: analysis of hygienic and sanitary conditions of food handlers].

    Science.gov (United States)

    de Souza, Giovanna Carbonera; dos Santos, Celso Tadeu Barbosa; Andrade, Anderson Assunção; Alves, Luciene

    2015-08-01

    The consumption of street food is an economical and practical alternative for the population. However, concerns regarding the safety of these foods are increasing. Thus, this study aimed to analyze the hygienic and sanitary conditions of the street food trade in Uberaba in the State of Minas Gerais. For this purpose, 30 street vending sites were evaluated using a structured questionnaire and microbiological analysis of food handlers' hands and food contact recipients and surfaces. The findings showed low adequacy of street food regarding hand hygiene and food contact surfaces. With respect to surfaces, the results for mesophilic aerobic microorganisms revealed that only 23.3% had satisfactory sanitary conditions. The level of contamination of hands by fecal thermotolerant coliforms and/or Coagulase positive Staphylococci was unsatisfactory in approximately 47% of food handlers. The conclusion drawn is that the hygienic and sanitary conditions of food handlers in Uberaba are poor. It is therefore necessary to adopt effective and permanent training programs on food safety for food handlers urgently.

  4. Pollution loads in urban runoff and sanitary wastewater.

    Science.gov (United States)

    Taebi, Amir; Droste, Ronald L

    2004-07-05

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.

  5. Pollution loads in urban runoff and sanitary wastewater

    International Nuclear Information System (INIS)

    Taebi, Amir; Droste, Ronald L.

    2004-01-01

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha·year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control

  6. Human waterborne parasites in zebra mussels ( Dreissena polymorpha) from the Shannon River drainage area, Ireland.

    Science.gov (United States)

    Graczyk, Thaddeus K; Conn, David Bruce; Lucy, Frances; Minchin, Dan; Tamang, Leena; Moura, Lacy N S; DaSilva, Alexandre J

    2004-08-01

    Zebra mussels ( Dreissena polymorpha) from throughout the Shannon River drainage area in Ireland were tested for the anthropozoonotic waterborne parasites Cryptosporidium parvum, Giardia lamblia, Encephalitozoon intestinalis, E. hellem, and Enterocytozoon bieneusi, by the multiplexed combined direct immunofluorescent antibody and fluorescent in situ hybridization method, and PCR. Parasite transmission stages were found at 75% of sites, with the highest mean concentration of 16, nine, and eight C. parvum oocysts, G. lamblia cysts, and Encephalitozoon intestinalis spores/mussel, respectively. On average eight Enterocytozoon bieneusi spores/mussel were recovered at any selected site. Approximately 80% of all parasites were viable and thus capable of initiating human infection. The Shannon River is polluted with serious emerging human waterborne pathogens including C. parvum, against which no therapy exists. Zebra mussels can recover and concentrate environmentally derived pathogens and can be used for the sanitary assessment of water quality.

  7. The sanitary officer: first aid coordinator on EDF nuclear power plant

    International Nuclear Information System (INIS)

    Masson, A.

    2000-01-01

    The internal organisation for first aid to the injured in case of an accident on E.D.F. nuclear power plant calls for the immediate assistance of a first aid team, consisting of five workers, under the direction of a principal first aid officer; one of the first aid workers, the sanitary officer who instructs the first aid workers intervention awaiting the arrival of an external medical. When the 'Sanitary on-site Emergency Plan' was up' dated, twenty medical doctors and seventy members of staff from five different sites were questioned as to the function of the sanitary officer. The conclusions revealed a notable difference of training amongst the different sites, and concerning first aid organisation, difference of priority of actions, extent of their participation once the medical team arrives and their participation in case of decontamination treatment. The medical doctors and staff lay a particular stress on importance of defining on a national scale the limits of role and responsibilities of the sanitary officer and establish a more specific training in this field, consequently motivating commitment and professionalism involvement. There is a great difference between the training and coaching of the first aid assistance and fire protection teams. To conclude, we propose that the first aid officer be known as first aid coordinator and the qualification of 'Certificat de Formation aux Premiers Secours en Equipe' in compliance with the current legislation together with a specific nuclear module and they should undergo regular on-site drills. (author)

  8. Food Safety and Sanitary Practices of Selected Hotels in Batangas Province, Philippines: Basis of Proposed Enhancement Measures

    Directory of Open Access Journals (Sweden)

    April M. Perez

    2017-02-01

    Full Text Available This study assessed the extent of food safety and sanitary practices of selected hotels in Batangas province as basis of proposed enhancement measures. The study utilized descriptive method to describe food safety and sanitary practices of selected hotels in Batangas province with a total of 8 hotels (256 respondents. Purposive sampling was used in the study. The questionnaires were designed using the provision of the Sanitation Code of the Philippines, validated and finalized to come up with legitimate results. The study showed that there were eight (8 hotel respondents classified as two, three, four star with considerable years of experience and adequate number of employees. The hotels demonstrated the food safety and sanitary practices always in the areas of restaurant, bar service, catering and banquet and room service. The significant pair-wise comparison for restaurant, bar service, catering and banquet and room service shows that 2 star hotels greatly differs. The researcher recommends that the management should maintain high standard of food safety and sanitary practices among its staff, upgrade the food safety and sanitary practices for food safety accreditation, continuous training of the hotel managers/employees on food safety and sanitary practices.

  9. Phase and Micro-Structural Characterization of Sanitary-Ware Fired at Different Temperature

    OpenAIRE

    ATHER HASSAN; YASEEN IQBAL; SYED ZAFAR ILYAS

    2017-01-01

    The three main ingredients of sanitary-ware are clay, feldspar and quartz. This ware is being widely used and has therefore, attracted the attention of researchers from time to time. Consequently, it has been extensively investigated. The present study describes the phase and micro-structural analysis of sanitary-ware samples collected from local (Durr Ceramics Peshawar) industry. XRD (X-Ray Diffraction) of samples fired at 1100oC reveals the presence of ? ? ? ? ?-quartz and primary mullite o...

  10. Transient drainage summary report

    International Nuclear Information System (INIS)

    1996-09-01

    This report summarizes the history of transient drainage issues on the Uranium Mill Tailings Remedial Action (UMTRA) Project. It defines and describes the UMTRA Project disposal cell transient drainage process and chronicles UMTRA Project treatment of the transient drainage phenomenon. Section 4.0 includes a conceptual cross section of each UMTRA Project disposal site and summarizes design and construction information, the ground water protection strategy, and the potential for transient drainage

  11. Prairie Pothole Region wetlands and subsurface drainage systems: Key factors for determining drainage setback distances

    Science.gov (United States)

    Tangen, Brian; Wiltermuth, Mark T.

    2018-01-01

    Use of agricultural subsurface drainage systems in the Prairie Pothole Region of North America continues to increase, prompting concerns over potential negative effects to the Region's vital wetlands. The U.S. Fish and Wildlife Service protects a large number of wetlands through conservation easements that often utilize standard lateral setback distances to provide buffers between wetlands and drainage systems. Because of a lack of information pertaining to the efficacy of these setback distances for protecting wetlands, information is required to support the decision making for placement of subsurface drainage systems adjacent to wetlands. We used qualitative graphical analyses and data comparisons to identify characteristics of subsurface drainage systems and wetland catchments that could be considered when assessing setback distances. We also compared setback distances with catchment slope lengths to determine if they typically exclude drainage systems from the catchment. We demonstrated that depth of a subsurface drainage system is a key factor for determining drainage setback distances. Drainage systems located closer to the surface (shallow) typically could be associated with shorter lateral setback distances compared with deeper systems. Subsurface drainage systems would be allowed within a wetland's catchment for 44–59% of catchments associated with wetland conservation easements in North Dakota. More specifically, results suggest that drainage setback distances generally would exclude drainage systems from catchments of the smaller wetlands that typically have shorter slopes in the adjacent upland contributing area. For larger wetlands, however, considerable areas of the catchment would be vulnerable to drainage that may affect wetland hydrology. U.S. Fish and Wildlife Service easements are associated with > 2,000 km2 of wetlands in North Dakota, demonstrating great potential to protect these systems from drainage depending on policies for installing

  12. The foam drainage equation for drainage dynamics in unsaturated porous media

    Science.gov (United States)

    Lehmann, P.; Hoogland, F.; Assouline, S.; Or, D.

    2017-07-01

    Similarity in liquid-phase configuration and drainage dynamics of wet foam and gravity drainage from unsaturated porous media expands modeling capabilities for capillary flows and supplements the standard Richards equation representation. The governing equation for draining foam (or a soil variant termed the soil foam drainage equation—SFDE) obviates the need for macroscopic unsaturated hydraulic conductivity function by an explicit account of diminishing flow pathway sizes as the medium gradually drains. The study provides new and simple analytical expressions for drainage rates and volumes from unsaturated porous media subjected to different boundary conditions. Two novel analytical solutions for saturation profile evolution were derived and tested in good agreement with a numerical solution of the SFDE. The study and the proposed solutions rectify the original formulation of foam drainage dynamics of Or and Assouline (2013). The new framework broadens the scope of methods available for quantifying unsaturated flow in porous media, where the intrinsic conductivity and geometrical representation of capillary drainage could improve understanding of colloid and pathogen transport. The explicit geometrical interpretation of flow pathways underlying the hydraulic functions used by the Richards equation offers new insights that benefit both approaches.

  13. DESIGN MANUAL: SULFIDE CONTROL IN SANITARY SEWERAGE SYSTEMS

    Science.gov (United States)

    One characteristic by which sanitary sewage is known to the public is its potential for creating odor nuisances. Sometimes it is the odors escaping from sewer manholes that cause complaints; more commonly, the source is a wastewater treatment plant. Yet there are wastewater treat...

  14. [Interaction of the bodies and institutions of the Russian Inspectorate for the protection of consumer rights and human welfare on sanitary-and-epidemiological examinations and issuing sanitary-and-epidemiological opinions].

    Science.gov (United States)

    Safonkina, S G

    2009-01-01

    The paper describes problems in the organization of the interaction of the Russian Inspectorate for the Protection of Consumer Rights and Human Welfare in Moscow and the Center for Hygiene and Epidemiology in Moscow to perform sanitary-and-epidemiological examinations and to issue sanitary-and-epidemiological opinions. The goals of setting up a one-window service and measures required for its effective work are defined. Positive results of one-window activities are shown.

  15. Sanitary sewer rehabilitation at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Vellinger, R. J.; Burton, R.; Fritschy, B.

    1995-04-01

    The objectives of this paper are the following: to present LLNL`s collection system and innovative approach to sanitary sewer rehabilitation; share issues identified and lessons learned from over four (4) years of rehabilitation work; and discuss proposed system standards for ongoing maintenance and repair activities.

  16. Rule concerning sanitary protection against ionizing radiations: novelties

    International Nuclear Information System (INIS)

    Bercedo, A.; Carmena, P.; Prieto, J. A.; Rubio, G.; Sollet, E.; Sustacha, D.

    2002-01-01

    Last July the a new legal Rule concerning Sanitary Protection against Ionising Radiation was published, as a transposition of the EU Directive about the Basic Norms related to the sanitary protection of workers and population against the risks resultant of the ionising radiation. The origin of this legislation goes back to the revision of the protection doctrine by the International Commission of Radiation Protection (ICRP) en the year 1990. El scope of the revised Rule is the regulation of the protection of population and workers against ionising radiation, the establishment of the national protection system with its exposition and dose limits and the correspondent penalty regime. It also modifies the maximum radiation dose limits and reinforces the application of the optimisation principle in the use of ionising radiation. In this article, the novelties introduced by the new Rule are commented in detail, ordered by the Titles I to IX in which the Rule is divided. (Author)

  17. Bibliography for acid-rock drainage and selected acid-mine drainage issues related to acid-rock drainage from transportation activities

    Science.gov (United States)

    Bradley, Michael W.; Worland, Scott C.

    2015-01-01

    Acid-rock drainage occurs through the interaction of rainfall on pyrite-bearing formations. When pyrite (FeS2) is exposed to oxygen and water in mine workings or roadcuts, the mineral decomposes and sulfur may react to form sulfuric acid, which often results in environmental problems and potential damage to the transportation infrastructure. The accelerated oxidation of pyrite and other sulfidic minerals generates low pH water with potentially high concentrations of trace metals. Much attention has been given to contamination arising from acid mine drainage, but studies related to acid-rock drainage from road construction are relatively limited. The U.S. Geological Survey, in cooperation with the Tennessee Department of Transportation, is conducting an investigation to evaluate the occurrence and processes controlling acid-rock drainage and contaminant transport from roadcuts in Tennessee. The basic components of acid-rock drainage resulting from transportation activities are described and a bibliography, organized by relevant categories (remediation, geochemical, microbial, biological impact, and secondary mineralization) is presented.

  18. About the tasks of the state sanitary-epidemiological service in public health protection and sanitary-epidemiological well-being of population and environment in case of radiation emergency situations

    International Nuclear Information System (INIS)

    Perminova, G.S.; Tuchkevich, E.A.

    1995-01-01

    The paper has stated the role of the State Sanitary-Epidemiological Service in the controlled radiation-emergency process on large, medium and small scale. The study reviews the phase character of radiation-emergency process, some typical features of their contents and the actions of the State Sanitary-Epidemiological Service, including non-radiation hygienic aspects; the characteristic features of supervision in case of small accidents are pointed out. Several scientific and practical problems on the raised subject which regarded to be urgent in the opinion of the authors are offered for consideration. 13 refs

  19. SANITARY ASPECT OF NUTRITION CONTROL IN PUBLIC KITCHEN IN NIS

    Directory of Open Access Journals (Sweden)

    Suzana Milutinovic

    2006-07-01

    Full Text Available The aim of the paper was to evaluate sanitary condition of food preparation and distribution in the "Public kitchen" in Nis, as well as the meals’ quality in order to assess the health risks. The local inspection of the objects and microbiological analysis of swaps were done according to standard methods. Energetical values and biochemical structure of the meals were assessed by bromatological methods and energetical density was calculated. The study was being conducted from 2002 – 2005. The results show that sanitary conditions in the object were not adequate, because of a high percentage of incorrect samples (13.4% from the total number of samples. Energetical values of meals were usually adequate (1157 – 1564 kcal, 4837 – 6581 kJ, but constantly decreased. The chemical structure of the meals was adequate too, meaning that meals were very well- planed. The energetic density of meals was high (1,18 – 1,42 kcal/g. Our conclusion is that there are no alternatives to continuous health care education of the medical stuff and regular sanitary hygienic control, all with the aim to accomplish complete social function of the public kitchen and to protect the health of its consumers.

  20. Frequency of anti hepatitis C virus antibodies amongst sanitary workers in a tertiary care hospital in Pakistan

    International Nuclear Information System (INIS)

    Khan, A.Z.; Razzaq, K.; Ansari, J.K.; Niazzi, S.K.

    2011-01-01

    Objective: To determine the frequency of anti Hepatitis C Virus antibodies in sanitary workers at Military Hospital Rawalpindi and to identify additional risk factors in them for hepatitis C infection. Cross sectional study Place and Duration of Study: Department of medicine, Military Hospital (M.H.), Rawalpindi, Pakistan over six months. Patients and Methods: All sanitary workers working at Military Hospital Rawalpindi were tested for anti HCV antibodies by third generation ELISA. Results: Six percent of the study population was found to be positive for anti HCV antibodies. Conclusion: The frequency of anti HCV antibodies is fairly high in sanitary workers, working in this tertiary care hospital studied. HCV infection is more frequent in those sanitary workers who have longer duration of service. (author)

  1. Factors associated with sanitary conditions of food and drinking ...

    African Journals Online (AJOL)

    Introduction: Food borne illness has been a global challenge and it persisted as a ... an absence of sanitary facilities for waste management was major cause. ... inspection on the establishments to promote and ensure proper hygiene and ...

  2. Drainage of radioactive areas

    International Nuclear Information System (INIS)

    1981-04-01

    This Code of Practice covers all the drainage systems which may occur in the radioactive classified area of an establishment, namely surface water, foul, process and radioactive drainage. It also deals with final discharge lines. The Code of Practice concentrates on those aspects of drainage which require particular attention because the systems are in or from radioactive areas and typical illustrations are given in appendices. The Code makes references to sources of information on conventional aspects of drainage design. (author)

  3. Analysis of biogas in sanitary landfill Caieiras

    Directory of Open Access Journals (Sweden)

    Giovano Candiani

    2011-06-01

    Full Text Available In this work, the biogas in the Sanitary Landfill Caieiras is qualitatively evaluated, emphasizing the influence of the geomembrana and cover system of vertical drains in the vicinity to capture the landfill. It was possible to detect an increase in the percentage of methane and oxygen reduction, aiming at the commercialization of carbon credits and electricity production.

  4. Indoor Environmental Conditions and Sanitary Practices in Selected ...

    African Journals Online (AJOL)

    Rapidly urbanizing cities are witnessing an increase in Day care centres (DCCs) whose environmental conditions are substandard. This scenario has negative consequences on the health of the DCC attendees and yet information on some of the indicators such as the level of sanitary practices is not adequately ...

  5. Aspects regarding the hygienic-sanitary conditions at the level of certain dental medicine cabinets in Iasi County.

    Science.gov (United States)

    Cernei, E R; Maxim, Dana Cristiana; Indrei, L L

    2013-01-01

    This baseline study aims to find out the evaluation of hygienic-sanitary conditions at the level of dental medicine cabinets through the verification of certain hygienic aspects. The study conducted consists in monitoring the hygienic/sanitary conditions at the level of 68 dental medicine cabinets (40 private cabinets and 28 school/university dental cabinets in Iasi county), using sheets for the assessment of the hygienic/sanitary conditions adapted from the control sheets of existing dental medicine cabinets at the level of DSP (Public Health Department) Iasi. The sheets for the assessment of the hygienic/sanitary conditions were evaluated by a specialized team and the results were i llustrated in the specific charts. At the level of all the dental cabinets the study revealed nonconformities regarding the means to carry out cleaning, disinfection operations, including the management of perilous waste, the control of medical personnel. An optimization of the hygienic-sanitary conditions at the level of dental medicine cabinets is still necessary, through participation to the activity of personnel training, who is directly involved in dental medical assistance.

  6. The application of irradiation to phyto sanitary problems

    Energy Technology Data Exchange (ETDEWEB)

    Ross, R T [USDA/APHIS/PPQ. Department of Agriculture, Room 1630 Soagribg, 1400 Independence Ave. Sw. Mail Code Stop 3438, 20250 Washington D.C. (United States)

    1998-12-31

    The first formally adopted regulatory policy for irradiation as a phyto sanitary treatment in the United States was issued in 1989 and was based on Title 7 of the Code of Federal Regulations. These regulations authorized irradiation as a quarantine treatment for papayas intended for movement from the State of Hawaii to the continental United States (U.S.), Guam, Puerto Rico, and the U.S. Virgin Islands. This authorization was specific for commodity, place of origin, and program, but was designed for a complex of three fruit flies rather than a single pest. Routine commercial shipments were never realized under this regulation due to the lack of a treatment facility in Hawaii. However, the authorization has proven useful from the standpoint of beginning to establish policies for irradiation as a phyto sanitary treatment in the United States. The United States Department of Agriculture (USDA), Animal and Plant Health Inspection Service (APHIS), Plant Protection and Quarantine (PPQ) remains dedicated to using the most up-to-date, appropriate and least intrusive technology to provide quarantine security. The need for alternative treatments for pests mitigation systems is greater than ever. Global trade pressures and the possible loss of methyl bromide make it imperative that all practical treatment options be explored. Since 1989 irradiation treatment concepts have matured significantly. Technological advances, greater experience, and an increasingly larger body of research indicate that irradiation has important potential as a treatment for quarantine pest problems. It is in this light that PPQ is expanding its regulatory framework, is addressing irradiation treatment options, and is developing comprehensive policy statements intended to facilitate the development and formalization of new treatments for phyto sanitary applications. (Author)

  7. The application of irradiation to phyto sanitary problems

    International Nuclear Information System (INIS)

    Ross, R.T.

    1997-01-01

    The first formally adopted regulatory policy for irradiation as a phyto sanitary treatment in the United States was issued in 1989 and was based on Title 7 of the Code of Federal Regulations. These regulations authorized irradiation as a quarantine treatment for papayas intended for movement from the State of Hawaii to the continental United States (U.S.), Guam, Puerto Rico, and the U.S. Virgin Islands. This authorization was specific for commodity, place of origin, and program, but was designed for a complex of three fruit flies rather than a single pest. Routine commercial shipments were never realized under this regulation due to the lack of a treatment facility in Hawaii. However, the authorization has proven useful from the standpoint of beginning to establish policies for irradiation as a phyto sanitary treatment in the United States. The United States Department of Agriculture (USDA), Animal and Plant Health Inspection Service (APHIS), Plant Protection and Quarantine (PPQ) remains dedicated to using the most up-to-date, appropriate and least intrusive technology to provide quarantine security. The need for alternative treatments for pests mitigation systems is greater than ever. Global trade pressures and the possible loss of methyl bromide make it imperative that all practical treatment options be explored. Since 1989 irradiation treatment concepts have matured significantly. Technological advances, greater experience, and an increasingly larger body of research indicate that irradiation has important potential as a treatment for quarantine pest problems. It is in this light that PPQ is expanding its regulatory framework, is addressing irradiation treatment options, and is developing comprehensive policy statements intended to facilitate the development and formalization of new treatments for phyto sanitary applications. (Author)

  8. The application of irradiation to phyto sanitary problems

    Energy Technology Data Exchange (ETDEWEB)

    Ross, R.T. [USDA/APHIS/PPQ. Department of Agriculture, Room 1630 Soagribg, 1400 Independence Ave. Sw. Mail Code Stop 3438, 20250 Washington D.C. (United States)

    1997-12-31

    The first formally adopted regulatory policy for irradiation as a phyto sanitary treatment in the United States was issued in 1989 and was based on Title 7 of the Code of Federal Regulations. These regulations authorized irradiation as a quarantine treatment for papayas intended for movement from the State of Hawaii to the continental United States (U.S.), Guam, Puerto Rico, and the U.S. Virgin Islands. This authorization was specific for commodity, place of origin, and program, but was designed for a complex of three fruit flies rather than a single pest. Routine commercial shipments were never realized under this regulation due to the lack of a treatment facility in Hawaii. However, the authorization has proven useful from the standpoint of beginning to establish policies for irradiation as a phyto sanitary treatment in the United States. The United States Department of Agriculture (USDA), Animal and Plant Health Inspection Service (APHIS), Plant Protection and Quarantine (PPQ) remains dedicated to using the most up-to-date, appropriate and least intrusive technology to provide quarantine security. The need for alternative treatments for pests mitigation systems is greater than ever. Global trade pressures and the possible loss of methyl bromide make it imperative that all practical treatment options be explored. Since 1989 irradiation treatment concepts have matured significantly. Technological advances, greater experience, and an increasingly larger body of research indicate that irradiation has important potential as a treatment for quarantine pest problems. It is in this light that PPQ is expanding its regulatory framework, is addressing irradiation treatment options, and is developing comprehensive policy statements intended to facilitate the development and formalization of new treatments for phyto sanitary applications. (Author)

  9. Effect of linear alkylbenzene mixtures and sanitary sewage in biochemical and molecular responses in pacific oyster Crassostrea gigas.

    Science.gov (United States)

    Flores-Nunes, Fabrício; Mattos, Jacó J; Zacchi, Flávia L; Serrano, Miguel A S; Piazza, Clei E; Sasaki, Silvio T; Taniguchi, Satie; Bicego, Márcia C; Melo, Cláudio M R; Bainy, Afonso C D

    2015-11-01

    Urban effluents are rich in nutrients, organic matter, pharmaceuticals and personal care products (PPCPs), pesticides, hydrocarbons, surfactants, and others. Previous studies have shown that oysters Crassostrea gigas accumulate significant levels of linear alkylbenzenes (LABs) in sanitary sewage contaminated sites, but there is little information about its toxicological effects in marine bivalves. The aim of this study was to analyze the transcription of genes in two tissues of C. gigas exposed for 12, 24, and 36 h to LABs or sanitary sewage. Likewise, the activity of antioxidant and biotransformation enzymes was measured in oysters exposed for 36 h in all groups. Oysters exposed to LABs and oysters exposed to sanitary sewage showed different patterns of transcriptional responses. LAB-exposed oysters showed lower level of biological responses than the oysters exposed to sanitary sewage. Despite the ability of the oyster C. gigas to accumulate LABs (28-fold), the data indicate that these contaminants are not the cause for the transcriptional responses observed in oysters exposed to sanitary sewage. Possibly, the biological changes observed in the sanitary sewage-exposed oysters are associated with the presence of other contaminants, which might have caused synergistic, additive, or antagonistic effects. The results show that FABP-like and GST-ω-like messenger RNAs (mRNAs) have a rapid response in tissues of oyster C. gigas exposed to sanitary sewage, suggesting a possible protective response and a role in maintaining homeostasis of these organisms.

  10. Are there still roles for exocrine bladder drainage and portal venous drainage for pancreatic allografts?

    Science.gov (United States)

    Young, Carlton J

    2009-02-01

    Controversy remains regarding the best methodology of handling exocrine pancreatic fluid and pancreatic venous effluent. Bladder drainage has given way to enteric drainage. However, is there an instance in which bladder drainage is preferable? Also, hyperinsulinemia, as a result of systemic venous drainage (SVD), is claimed to be proatherosclerotic, whereas portal venous drainage (PVD) is more physiologic and less atherosclerotic. Bladder drainage remains a viable method of exocrine pancreas drainage, but evidence is sparse that measuring urinary amylase has a substantial benefit in the early detection of acute rejection in all types of pancreas transplants. Currently, there is no incontrovertible evidence that systemic hyperinsulinemia is proatherosclerotic, whereas recent metabolic studies on SVD and PVD showed that there was no benefit to PVD. Given the advent of newer immunosuppressive agents and overall lower acute rejection rates, the perceived benefit of bladder drainage as a means to measure urinary amylase as an early marker of rejection has not been substantiated. However, there may be a selective role for bladder drainage in 'high risk' pancreases. Also, without a clear-cut metabolic benefit to PVD over SVD, it remains the surgeon's choice as to which method to use.

  11. Sanitary services in the perm region during the Great Patriotic war

    Directory of Open Access Journals (Sweden)

    V.A. Horoshavin

    2015-06-01

    Full Text Available The article is devoted to the history of the formation of the Medical Service of the (Molotov region during the war. We describe the problems encountered sanitary doctors in the war years, the direction of the main measures to address these problems. It is shown that the organizers of the health service – A.V. Kostina, V.A. Ryazanov, their colleagues have made every effort to prevent epidemics and save health of both local and evacuees. It is showed the role of volunteers, doctors of medical units at the plants, the Department of Health Medical Institute to improve the sanitary conditions in the region.

  12. Subsurface drainage volume reduction with drainage water management: Case studies in Ohio, USA

    Science.gov (United States)

    One of the main contributors to poor water quality in the Mississippi River and aeral increase in the hypoxic zone in the Gulf of Mexico is intensive drainage of the cropland within the watershed. Controlled drainage has been demonstrated as an approach to curb totla drainage outflow and nutrient di...

  13. Conceptual design report, 200 Area sanitary sewer system: Project 96L-EWL-116

    International Nuclear Information System (INIS)

    Pursley, D.L.

    1994-01-01

    Project L-116 will install an integrated sanitary sewer system in the 200 Area. This new system will connect existing sewer systems for facilities that have a foreseeable future, provide capacity and routing for future facilities, and install new septic sewer systems for existing facilities that cannot be feasibly connected to the new sewer system and have a mission that will extend beyond the year 2000. Project L-116 will construct a sanitary sewer collection, treatment, and disposal system for facilities in the 200-East and -West Areas and adjacent areas located on the 200 Area plateau. The existing septic systems will be abandoned or decommissioned in accordance with applicable Washington State and local codes and regulations. The conceptual design for the sanitary sewer system is designed around population forecasts of 5,000 people for 200-West Area and 9,000 people for 200-East Area. The definitive design will be based on the latest forecast populations at the time definitive design is initiated

  14. Solidarity: an innovative perspective in the management and organization of Sanitary Surveillance actions.

    Science.gov (United States)

    Leal, Cristian Oliveira Benevides Sanches; Teixeira, Carmen Fontes de Souza

    2017-10-01

    This is a theoretical essay about the development of the concept of solidarity, a word used in the regulatory framework and in political proposals to reorient the Brazilian Unified Health System (SUS). The methodology consisted of mapping authors addressing human action aspects related to this theme from Durkheim's tradition, linking them to his followers, like Marcel Mauss and authors from the "anti-utilitarianism" movement in social sciences. Solidarity is one way to express a "gift" and appears as a multidimensional action, where duty and freedom, instrumental interest and disinterest interpose and interlace. The planning and execution of sanitary surveillance (VISA) actions requires comprehension of organizational forms and solidary relationship management among agents involved in health risk control, transcending the strongly normative aspect of the prevailing supervision actions. The development of associative actions involving sanitary surveillance professionals, economic agents and consumers, aiming to share the responsibilities in the health risk control of products, services and environments subjected to Sanitary Surveillance action is suggested.

  15. [Power and health in South America: international sanitary conferences, 1870-1889].

    Science.gov (United States)

    Chaves, Cleide de Lima

    2013-06-01

    This article analyzes the international sanitary conferences that were held in South America in 1873 and 1887, involving the Brazilian Empire and the Republics of Argentina and Uruguay, as an integral part of a series of similar events that took place in Europe and North America starting in the second half of the nineteenth century. The interests of the countries involved, namely trade relations and immigration from Europe - both directly affected by the epidemics - are discussed, and the repercussions of these sanitary agreements on the other countries in the Americas are indicated. The American health conventions in the late nineteenth century represented the first initiatives in the Americas to solve international public health problems.

  16. Effects of supplement with sanitary landfill leachate in gas exchange of sunflower (Helianthus annuus L.) seedlings under drought stress.

    Science.gov (United States)

    Nunes Junior, Francisco H; Freitas, Valdineia S; Mesquita, Rosilene O; Braga, Brennda B; Barbosa, Rifandreo M; Martins, Kaio; Gondim, Franklin A

    2017-10-01

    Sanitary landfill leachate is one of the major problems arising from disposal of urban waste. Sanitary landfill leachate may, however, have use in agriculture. This study, therefore, aimed to analyze initial plant growth and gas exchange in sunflower seedlings supplemented with sanitary landfill leachate and subjected to drought stress through variables of root fresh mass (RFM), shoot fresh mass (SFM), total fresh mass (TFM), relative chlorophyll content (CL), stomatal conductance (g s ), transpiration rate (E), net photosynthetic rate (A), ratio of internal to external CO 2 concentration (Ci/Ca),water use efficiency (EUA), instantaneous carboxylation efficiency (A/Ci), and electron transport rate (ETR). The experimental design was a completely randomized 2 (irrigated and non-irrigated) × 4 (sand, sand + 100 kg N ha -1 organic fertilizer, sand + 100 kg N ha -1 sanitary landfill leachate, and sand + 150 kg N ha -1 sanitary landfill leachate) factorial with five replicates. Under drought stress conditions, leachate treatment supplemented with 100 kg N ha -1 exhibited higher plant fresh weights than those of the treatment containing 150 kg N ha -1 . Increases in fresh mass in plant treatments supplemented with 100 and 150 kg N ha -1 sanitary landfill leachate were related to higher photosynthetic rates.

  17. In-office drainage of sinus Mucoceles: An alternative to operating-room drainage.

    Science.gov (United States)

    Barrow, Emily M; DelGaudio, John M

    2015-05-01

    Endoscopic drainage has become the standard of care for the treatment of mucoceles. In many patients this can be performed in the office. This study reviews our experience with in-office endoscopic mucocele drainage. Retrospective chart review. A retrospective review of one surgeon's experience with in-office endoscopic drainage of sinus mucoceles between 2006 and 2014 was performed. Charts were reviewed for patient demographics, previous surgery, mucocele location, bone erosion, and outcomes. Thirty-two patients underwent 36 in-office drainage procedures. All procedures were performed under topical/local anesthesia. The mean age was 55 years (range, 17-92 years). The mean follow-up time was 444 days. Fifty-five percent had previous sinus surgery. The primary sinus involved was the frontal (12), anterior (11), posterior ethmoid (six), maxillary (four), and sphenoid (two). Bone erosion was noted to be present on computed tomography in 18 mucoceles (51%) (16 orbital, seven skull-base). All mucoceles were successfully accessed in the office with the exception of one, which was aborted due to neo-osteogenesis. Five patients (14% of mucoceles) required additional surgery, two for mucocele recurrence and three for septated mucoceles not completely drained in the office. No treatment complications occurred. All but one patient preferred in-office to operating-room drainage. In-office drainage of sinus mucoceles is well tolerated by patients, with high success and low complication rates, even in large mucoceles with bone erosion. The presence of septations and neo-osteogenesis reduce the likelihood of complete drainage and are relative contraindications. Orbital and skull base erosion are not contraindications. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  18. 40 CFR 141.723 - Requirements to respond to significant deficiencies identified in sanitary surveys performed by EPA.

    Science.gov (United States)

    2010-07-01

    ... deficiencies identified in sanitary surveys performed by EPA. 141.723 Section 141.723 Protection of Environment... performed by EPA, systems must respond in writing to significant deficiencies identified in sanitary survey... will address significant deficiencies noted in the survey. (d) Systems must correct significant...

  19. Considering the sanitary aspects in regional plans for air quality. Situation of sanitary impacts of urban air pollution studies; Prise en compte des aspects sanitaires dans les Plans regionaux pour la qualite de l'air. Bilan des etudes d'impact sanitaires de la pollution atmospherique urbaine realisees

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-15

    The law on air and the rational use of energy of the 30. september 1996 forecasts the setting up of regional planning for the air quality that have to rely on the support of an evaluation of sanitary effects of air pollution. To help the local sanitary authorities in this mission, the National Institute of Sanitary Surveillance and the C.I.R.E. have realised a methodological guide on evaluation of sanitary impact of urban air pollution in different contexts. (N.C.)

  20. Methodological issues of optimization the sanitary-educational assistance for children with asthma during the health care reform of Ukraine

    Directory of Open Access Journals (Sweden)

    S. N. Nedelskaya

    2013-08-01

    Full Text Available Entry. Asthma remains the medical, social, economic issue of the day of modern society and industry of health protection. Research works on questions asthma are sanctified to mainly the improvement of diagnostics and treatment of asthma and a sanitary-educational help is underestimated. In the modern terms of structural alteration of network of establishments of health care in Ukraine a sanitary-educational help must be an effective complex in strategy of therapy of patients with asthma. Research aim. To ground importance, modern forms and methods of sanitary -educational help in providing of control above asthma on the stage of structural reorganization of establishments of health care in Ukraine. Materials and research methods. Scientifically-methodical literature was analyzed on general questions of organization and realization of sanitary-educational work in asthma. Long-term of own experience of realization of this work is generalized in the conditions of stationary treatment of patients with asthma. Research results. Sanitary-educational work in a form of education in the program "Asthma school". General practitioner, as a key figure of establishments of primary medical and sanitary help, must own the psychological methods including medical-psychology programs of before- and after graduation medical education. Conclusions. In providing of effective control above bronchial asthma in children a sanitary-educational help must be logical continuation and addition of curative help. Application of the educational programs and volume of work of doctors at their implementation must be legislatively lighted up in "Protocols of diagnostics and treatment of bronchial asthma for children".

  1. Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods

    Directory of Open Access Journals (Sweden)

    Kênia de Fátima Carrijo

    2014-06-01

    Full Text Available ABSTRACT. Carrijo K.F., Nascimento E.R., Pereira V.L.A., Morés N., Klein, C.S., Domingues L.M. & Tortelly R. [Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods.] Diagnóstico da pneumonia enzoótica suína pela inspeção sanitária post mortem: comparação com outros métodos de diagnóstico. Revista Brasileira de Veterinária Brasileira 36(2:188-194, 2014. Faculdade de Medicina Veterinária, Universidade Federal de Uberlândia, Av. Pará, 1720, Bloco 2T, Jardim Umuarama, Uberlândia, MG 38400-902, Brasil. E-mail: keniacarrijo@ famev.ufu.br To compare the concordance of the diagnosis of porcine enzootic pneumonia (PEP by post-mortem Sanitary Inspection with other methods (histophatology and immunohistochemistry - IHC, were used lung tissue samples from 100 pigs slaughtered under sanitary inspection, and 50 of these had macroscopic lesions suggestive of PEP and 50 had no such lesions. These were fixed in 10% buffered formalin and processed by routine procedures for paraffin embedding and IHC technique for Mycoplasma hyopneumoniae using a monoespecific polyclonal antibody. The study demonstrating that there is concordance between the diagnosis of Sanitary Inspection with histophatology, between the diagnosis of Sanitary Inspection with IHC and histophatology with IHC. It can be conclude that when the lung has gross lesions of PEP, the probability the result is positive to M. hyopneumoniae by IHC and the presence of microscopic lesions increases. Thus, the microscopic diagnosis for PEP is feasible because it is associated to the other, so that the diagnosis given by the officials of Sanitary Inspection in slaughterhouses is not wrong; the macroscopic diagnosis is therefore a valid method for the diagnosis of PEP, it being understood this is not to say that the detection of M. hyopneumoniae.

  2. Tertiary Treatment and Recycling of Wastewater

    Science.gov (United States)

    2015-05-18

    of the Worrell design (Figure 2.1) illustrates the modular treatment cells filled with vitrified expanded clay (or similar media) and planted with...General Construction Storm Water permit Sanitary / Storm Drainage Restriction: Absolutely no materials are to be disposed of via the sanitary ...sewer or storm water systems without consulting the Environmental Office. Exception: Water may be discharged down the sanitary sewer when:  The

  3. Percutaneous drainage of lung abscesses

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; D'Agostino, H.; Casola, G.; Vatney, R.R.; Wittich, G.R.; Harker, C.

    1989-01-01

    The authors performed percutaneous drainage of lung abscesses in 12 patients. Indications for drainage were septicemia and persistence or worsening of radiographic findings. These lung abscesses were refractory to intravenous antibiotics and to bronchial toilet. Etiology of the abscesses included pneumonia (most frequently), trauma, postoperative development, infected necrotic neoplasm, and infected sequestration. Guidelines for drainage included passage of the catheter through contiguously abnormal lung and pleura, inability of the patient to cough, and/or bronchial obstruction precluding bronchial drainage. Cure was achieved in 11 of 12 patients. Catheters were removed on an average of 16 days after insertion. Antibiotics were administered an average of 18 days before drainage. No major complications occurred

  4. [Evaluation of the hygienic-sanitary conditions of kitchens in public and philanthropic daycare centers].

    Science.gov (United States)

    Oliveira, Mariana de Novaes; Brasil, Anne Lise Dias; Taddei, José Augusto de Aguiar Carrazedo

    2008-01-01

    This paper aims to evaluate the hygienic-sanitary conditions of kitchens in philanthropic and public daycare centers in the city of São Paulo using a tool of easy application. Information on the hygienic-sanitary conditions was gathered observing the operational conditions of five public and philanthropic daycare centers in the city of São Paulo. A score was developed for classifying the risks of food contamination. The operational conditions in the kitchens of the studied philanthropic and public daycare centers in the city of São Paulo can result in contamination of the prepared food. Among the most important risk factors for food contamination is the behavior of the workers who handle the food. Training and continuous supervision of the involved personnel are the best and easiest alternatives for assuring the appropriate hygienic-sanitary conditions and quality of the food offered to the children in these daycare centers.

  5. Percutaneous catheter drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub [Catholic University Medical college, Seoul (Korea, Republic of)

    1993-09-15

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess.

  6. Percutaneous catheter drainage of lung abscess

    International Nuclear Information System (INIS)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub

    1993-01-01

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess

  7. The Sanitary Conditions of Food Service Establishments and Food ...

    African Journals Online (AJOL)

    Sixty six percent of the establishments had flush toilets whereas 5.9% of the establishment had no toilet. Only 149 (33.6%) of the establishments had a proper solid waste collection receptacle and there was statistically significant association between the sanitary conditions and license status of the establishments (p=0.01).

  8. Routine Sub-hepatic Drainage versus No Drainage after Laparoscopic Cholecystectomy: Open, Randomized, Clinical Trial.

    Science.gov (United States)

    Shamim, Muhammad

    2013-02-01

    Surgeons are still following the old habit of routine subhepatic drainage following laparoscopic cholecystectomy (LC). This study aims to compare the outcome of subhepatic drainage with no drainage after LC. This prospective study was conducted in two phases. Phase I was open, randomized controlled trial (RCT), conducted in Civil Hospital Karachi, from August 2004 to June 2005. Phase II was descriptive case series, conducted in author's practice hospitals of Karachi, from July 2005 to December 2009. In phase I, 170 patients with chronic calculous cholecystitis underwent LC. Patients were divided into two groups, subhepatic drainage (group A: 79 patients) or no drainage (group B: 76 patients). The rest 15 patients were excluded either due to conversion or elective subhepatic drainage. In phase II, 218 consecutive patients were enrolled, who underwent LC with no subhepatic drainage. Duration of operation, character, and amount of drain fluid (if placed), postoperative ultrasound for subhepatic collection, postoperative chest X-ray for the measurement of subdiaphragmatic air, postoperative pain, postoperative nausea/vomiting, duration of hospital stay, and preoperative or postoperative complications were noted and analyzed. Duration of operation and hospital stay was slightly longer in group A patients (P values 0.002 and 0.029, respectively); postoperative pain perception, nausea/vomiting, and postoperative complications were nearly same in both groups (P value 0.064, 0.078, and 0.003, respectively). Subhepatic fluid collection was more in group A (P = 0.002), whereas subdiaphragmatic air collection was more in group B (P = 0.003). Phase II results were nearly similar to group B patients in phase I. Routine subhepatic drainage after LC is not necessary in uncomplicated cases.

  9. NORTH PORTAL-SANITARY SEWER CALCULATION-SHOP BUILDING No.5006

    International Nuclear Information System (INIS)

    S. Blackstone

    1996-01-01

    The purpose of this design calculation is to determine the demand on the waste system and to size the sanitary sewer line serving the Shop Building No.5006 in accordance with the Uniform Plumbing Code (Section 4.4.1) and US Department of Energy Order 6430.1A-1540 (Section 4.4.2)

  10. Nutrition of pigs kept under low and high sanitary conditions

    NARCIS (Netherlands)

    Meer, van der Yvonne

    2017-01-01

    It is economically and environmentally important to match the nutrient supply to the nutrient requirements in pig production. Until now, the effects of different sanitary conditions on energy and nutrient requirements are not implemented in recommendations for nutrient composition of pig diets.

  11. 49 CFR Appendix C to Part 228 - Guidelines for Clean, Safe, and Sanitary Railroad Provided Camp Cars

    Science.gov (United States)

    2010-10-01

    ... steady sound level which in 8 hours would contain the same acoustic energy as the time-varying sound... changed regularly. 7. Lavatories. (a) Lavatories should be made available to all rail employees housed in... sanitary condition. (e) Sanitary storage. No food or beverages should be stored in toilet rooms or in an...

  12. Endoscopic Ultrasound-Guided Perirectal Abscess Drainage without Drainage Catheter: A Case Series

    Directory of Open Access Journals (Sweden)

    Eun Kwang Choi

    2017-05-01

    Full Text Available A perirectal abscess is a relatively common disease entity that occurs as a postsurgical complication or as a result of various medical conditions. Endoscopic ultrasound (EUS-guided drainage was recently described as a promising alternative treatment. Previous reports have recommended placement of a drainage catheter through the anus for irrigation, which is inconvenient to the patient and carries a risk of accidental dislodgement. We report four cases of perirectal abscess that were successfully treated with only one or two 7 F double pigtail plastic stent placements and without a drainage catheter for irrigation.

  13. Relativistic electron influence on sanitary-model microorganisms and antibiotics in model samples

    International Nuclear Information System (INIS)

    Antipov, V.S.; Berezhna, I.V.; Kovpik, O.F.; Babych, E.M.; Voliansky, Yu.L.; Sklar, N.I.

    2004-01-01

    A series of the investigations of the electron beam influence on sanitary-model test cultures and antibiotics in model solutions has been carried out. For each of the test objects, the authors have found the boundary doses of the absorbed radiation. The higher doses cause the sharp increase in the bactericidal influence, which becomes complete. The sanitary-bactericidal indices of the water samples remain sable during 6 days. The samples of antibiotics in various concentrations (from 100 UA) have been irradiated. It is proved that the substratum processing by the beam (in the regimes 30 kGy) causes diminution and complete neutralization of the antibacterial activity in all probes of the samples

  14. Conducting Sanitary Surveys of Water Supply Systems. Student Workbook.

    Science.gov (United States)

    1976

    This workbook is utilized in connection with a 40-hour course on sanitary surveys of water supply systems for biologists, chemists, and engineers with experience as a water supply evaluator. Practical training is provided in each of the 21 self-contained modules. Each module outlines the purpose, objectives and content for that section. The course…

  15. Exploring Agricultural Drainage's Influence on Wetland and ...

    Science.gov (United States)

    Artificial agricultural drainage (i.e. surface ditches or subsurface tile) is an important agricultural management tool. Artificial drainage allows for timely fieldwork and adequate root aeration, resulting in greater crop yields for farmers. This practice is widespread throughout many regions of the United States and the network of artificial drainage is especially extensive in flat, poorly-drained regions like the glaciated Midwest. While beneficial for crop yields, agricultural drains often empty into streams within the natural drainage system. The increased network connectivity may lead to greater contributing area for watersheds, altered hydrology and increased conveyance of pollutants into natural water bodies. While studies and models at broader scales have implicated artificial drainage as an important driver of hydrological shifts and eutrophication, the actual spatial extent of artificial drainage is poorly known. Consequently, metrics of wetland and watershed connectivity within agricultural regions often fail to explicitly include artificial drainage. We use recent agricultural census data, soil drainage data, and land cover data to create estimates of potential agricultural drainage across the United States. We estimate that agricultural drainage in the US is greater than 31 million hectares and is concentrated in the upper Midwest Corn Belt, covering greater than 50% of available land for 114 counties. Estimated drainage values for numerous countie

  16. Mine Drainage Generation and Control Options.

    Science.gov (United States)

    Wei, Xinchao; Rodak, Carolyn M; Zhang, Shicheng; Han, Yuexin; Wolfe, F Andrew

    2016-10-01

    This review provides a snapshot of papers published in 2015 relevant to the topic of mine drainage generation and control options. The review is broken into 3 sections: Generation, Prediction and Prevention, and Treatment Options. The first section, mine drainage generation, focuses on the characterization of mine drainage and the environmental impacts. As such, it is broken into three subsections focused on microbiological characterization, physiochemical characterization, and environmental impacts. The second section of the review is divided into two subsections focused on either the prediction or prevention of acid mine drainage. The final section focuses on treatment options for mine drainage and waste sludge. The third section contains subsections on passive treatment, biological treatment, physiochemical treatment, and a new subsection on beneficial uses for mine drainage and treatment wastes.

  17. FLORIDA HAZARDOUS WASTE AND SANITARY LANDFILL REPORT, COUNTY DATA. GENERATOR DATA AND CHARACTERISTICS OF SANITARY LANDFILLS. PART 2. COUNTIES: BROWARD, CALHOUN, CHARLOTTE, CITRUS, CLAY, COLLIER

    Science.gov (United States)

    The report provides data on the use of sanitary landfills (Subtitle D facilities) for hazardous waste disposal in Florida by small quantity generators. It consists of eleven parts including a part called Study Area Data which contains the data aggregated across the counties cover...

  18. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  19. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  20. [Sanitary and epidemiological supply for the Russian Army during the First World War (1914-1918)].

    Science.gov (United States)

    gorelova, L E; Loktev, A E

    2014-02-01

    At the beginning of the First World War the most typical diseases in the Russian Army were typhoid, typhus, diphtheria, cholera, smallpox and other infectious diseases. At the beginning of the First World War the level of infectious morbidity was significantly low, but further increased and pandemic risk arose. Servicemen were mostly ill with typhus, relapsing fever, flux, cholera, smallpox and typhoid. The highest mortality rate was registered in patients with cholera, typhus and typhoid. According the prewar deployment program of the Russian Army anti-epidemiologic facilities were established. By the end of war were established 110 sanitary-and-hygienic and 90 disinfection units. However, organization of anti-epidemiologic security was unsatisfactory. Due to lack of specialists and equipment anti-epidemiologic facilities of units were under strength. Commanders of sanitary units and sanitary service had not enough resources for operational service in the Forces and facilities of rear area.

  1. Comparison of natural drainage group and negative drainage groups after total thyroidectomy: prospective randomized controlled study.

    Science.gov (United States)

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum; Son, Young-Ik

    2013-01-01

    The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. The amount of drainage during the first 24 hours postoperatively was 41.68 ± 3.93 mL in the negative drain group and 25.3 ± 2.68 mL in the natural drain group (pdrain group was 35.19 ± 4.26 mL and natural drain groups 21.53 ± 2.90 mL (pdrain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done.

  2. [Sanitary and epidemiological conditions in the Lodz region during the period of the second Polish Republic in the XIX and XX centuries].

    Science.gov (United States)

    Sadowska, Jolanta

    2005-01-01

    Throughout history of European agglomerations in the nineteenth and twentieth century the relation between expanding industry and worsening sanitary and epidemiological conditions was seen. These changes, having great impact on public health, were investigated in the present study. Problems related to sanitary and epidemiological conditions in Lodz first emerged during the Russian occupation of Poland in the XIX century. The Russian Governing Council was not overseeing sanitary conditions of the city, and transferred this responsibility to the industrial bourgeoisie of Lodz. In this situation, uncontrolled development of the industry led to serious deterioration in natural environment and increase of risk for acute and chronic infectious diseases. Improvement of the sanitary situation in Lodz commenced in the period of the Second Polish Republic (1918-1939). Sanitary Divisions were created at the Lodz Department of Public Health. Activities in this Department involved, among others, detailed epidemiological examination of potable water, the investigation of manufacturing processes, retail and wholesale groceries, hygienic conditions of public housing. The activity and interventions of Sanitary Divisions contributed substantially to a decrease of incidence of various diseases and improvement of living conditions of the Lodz populations. The improvement of sanitary and epidemiological conditions in Lodz after 1918 was mainly related to the construction of water supply and sewage systems. This led to an approximation of the urban standards of this 500,000 population agglomeration to European standards.

  3. Drainage filter technologies to mitigate site-specific phosphorus losses in agricultural drainage discharge

    DEFF Research Database (Denmark)

    Kjærgaard, Charlotte; Heckrath, Goswin Johann; Canga, Eriona

    in drainage. The Danish “SUPREME-TECH” project (2010-2016) (www.supreme-tech.dk) aims at providing the scientific basis for developing cost-effective filter technologies for P in agricultural drainage waters. The project studies different approaches of implementing filter technologies including drainage well....... Targeting high risk areas of P loss and applying site-specific measures promises to be a cost-efficient approach. The Danish Commission for Nature and Agriculture has, therefore, now called for a paradigm shift towards targeted, cost-efficient technologies to mitigate site-specific nutrient losses...... environmental threshold values (

  4. [V.P. Kravkov as a sanitary physician of the Russian Imperial Army (to centenary of beginning of the First World War)].

    Science.gov (United States)

    Uzbekova, D G

    2014-01-01

    The article presents for the first time the description of life story and service of V.P. Kravkov (1859-1920)--participant of Russian-Japanese war and the First World War, doctor of medicine, sanitary physician of the Russian Imperial Army and author of number of books and articles on preventive medicine. During these two wars, V.P. Kravkov organized sanitary epidemiological service in fronts. He kept diary regularly reflecting conditions of sanitary epidemiological service during this period, describing one's own observations and assessing survived events. The manuscripts of diaries are stored in the Russian state library. The diaries made great input into summarizing of experience of the Russian military sanitary service and became valuable monument of military memoirs' literature.

  5. Diptera of sanitary importance associated with composting of biosolids in Argentina

    Directory of Open Access Journals (Sweden)

    Valeria Alejandra Labud

    2003-12-01

    Full Text Available OBJECTIVE: Odorous compounds produced at the biosolids composting plant in Bariloche (NW Patagonia attract a variety of insects, mainly belonging to the order Diptera. In order to characterize these flies, collected specimens were taxonomically identified, their community characteristics were described and their sanitary and synanthropic importance and autochthonous or introduced character were determined. METHODS: Sampling was performed from October 1999 until March 2000. Adults were collected using an entomological net, and larvae and puparia were obtained from the composting material and incubated to obtain adults. Richness, abundance and sex ratio were calculated. RESULTS: A total of 9 taxa of Diptera were identified: Sarconesia chlorogaster, Phaenicia sericata, Calliphora vicina, Cochliomya macellaria, Ophyra sp, Muscina stabulans, Musca domestica, Sarcophaga sp and Fannia sp. Specimens of Anthomyiidae, Acaliptratae and one larva of Eristalis tenax were also found. Ophyra sp. was the most abundant taxa. All the captured Diptera belonged to introduced taxa. Most of them are considered to be eusynanthropic and/or hemisynanthropic and have sanitary importance as they may cause myiasis and pseudomyiasis. The high number of females registered and the finding of immature stages indicated that flies can develop their complete life cycle on biosolid composting windrows. CONCLUSIONS: The characterization of flies obtained in this study may be useful for defining locations of urban or semi-urban composting facilities. It also highlights the importance of sanitary precautions at such plants.

  6. [Ascites drainage at home

    NARCIS (Netherlands)

    Lutjeboer, J.; Erkel, A.R. van; Hoeven, J.J.M. van der; Meer, R.W. van der

    2015-01-01

    Ascites can lead to many symptoms, and often occurs in patients with an end-stage malignancy such as ovarian, pancreatic, colonic, or gastric cancer. Intermittent ascites drainage is applied in these patients as a palliative measure. As frequent drainage is necessary, a subcutaneously tunnelled

  7. Percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Hong, Seong Mo; Han, Man Chung

    1982-01-01

    Percutaneous transhepatic biliary drainage was successfully made 20 times on 17 patients of obstructive jaundice for recent 1 year since June 1981 at Department of Radiology in Seoul National University Hospital. The causes of obstructive jaundice was CBD Ca in 13 cases, metastasis in 2 cases, pancreatic cancer in 1 case and CBD stone in 1 case. Percutaneous transhepatic biliary drainage is a relatively ease, safe and effective method which can be done after PTC by radiologist. It is expected that percutaneous transhepatic biliary drainage should be done as an essential procedure for transient permanent palliation of obstructive jaundice

  8. COMPUTER MODEL ANALYSIS FOR MITIGATION PLANNING OF SANITARY-SEWER OVERFLOWS

    Science.gov (United States)

    Sanitary sewer overflows (SSOs) are generally difficult to witness or document as they usually occur during rain events when people are indoors or out of sight. To anser where and when an SSO may occur, it is necessary to know the flow conveyance capacity at various parts of the ...

  9. Determination of the gaseous emission of toxic substances in the Curva de Rodas sanitary landfill in Medellin

    International Nuclear Information System (INIS)

    Garcia Renteria, Francisco Fernando; Agudelo Garcia, Ruben Alberto

    2005-01-01

    Results of the investigation conducted at the sanitary landfill Curva de Rodas, aimed to determine the emission and migration of toxic substances are presented. Traces of benzene, toluene, hexane, vinyl chloride and xylene were found. Concentrations of these substances were, however, below threshold limits at the landfill and below detectable limits in the air of populated areas adjacent to the sanitary landfill

  10. Sanitary hot water; Eau chaude sanitaire

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Cegibat, the information-recommendation agency of Gaz de France for building engineering professionals, has organized this conference meeting on sanitary hot water to present the solutions proposed by Gaz de France to meet its clients requirements in terms of water quality, comfort, energy conservation and respect of the environment: quantitative aspects of the hot water needs, qualitative aspects, presentation of the Dolce Vita offer for residential buildings, gas water heaters and boilers, combined solar-thermal/natural gas solutions, key-specifications of hot water distribution systems, testimony: implementation of a gas hot water reservoir and two accumulation boilers in an apartment building for young workers. (J.S.)

  11. Ecotoxicological evaluation of leachate from the Limeira sanitary landfill with a view to identifying acute toxicity

    OpenAIRE

    José Euclides Stipp Paterniani; Ronaldo Teixeira Pelegrini; Núbia Natália de Brito Pelegrini

    2007-01-01

    Final disposal of solid waste is still a cause for serious impacts on the environment. In sanitary landfills, waste undergoes physical, chemical, and biological decomposition, generating biogas and leachate. Leachate is a highly toxic liquid with a very high pollution potential. The purpose of this work is to evaluate toxicity of in natura leachate samples collected from Limeira Sanitary Landfill, in Limeira, SP. The ecotoxicological evaluation comprised acute toxicity assays using as test or...

  12. Florence Nightingale and the India sanitary reforms.

    Science.gov (United States)

    Hays, J C

    1989-09-01

    After the Crimean War, Florence Nightingale persisted in researching the health conditions of British troops throughout the Empire. Undaunted by geographic limitations, she surveyed and publicized data that documented the mismanagement of living conditions and health care among the occupational forces on the Indian continent. Nightingale proposed widespread changes in the reporting of military health status and biostatistics, in sanitary engineering, and in self-care activities. With dogged persistence, she continued to gather follow-up data to measure the changing health status of soldiers in a land she never saw.

  13. Agricultural drainage water quality

    International Nuclear Information System (INIS)

    Madani, A.; Gordon, R.

    2002-01-01

    'Full text:' Agricultural drainage systems have been identified as potential contributors of non-point source pollution. Two of the major concerns have been with nitrate-nitrogen (NO3 - -N) concentrations and bacteria levels exceeding the Maximum Acceptable Concentration in drainage water. Heightened public awareness of environmental issues has led to greater pressure to maintain the environmental quality of water systems. In an ongoing field study, three experiment sites, each with own soil properties and characteristics, are divided into drainage plots and being monitored for NO3 - -N and fecal coliforms contamination. The first site is being used to determine the impact of the rate of manure application on subsurface drainage water quality. The second site is being used to determine the difference between hog manure and inorganic fertilizer in relation to fecal coliforms and NO3-N leaching losses under a carrot rotation system. The third site examines the effect of timing of manure application on water quality, and is the only site equipped with a surface drainage system, as well as a subsurface drainage system. Each of the drains from these fields lead to heated outflow buildings to allow for year-round measurements of flow rates and water samples. Tipping buckets wired to data-loggers record the outflow from each outlet pipe on an hourly basis. Water samples, collected from the flowing drains, are analyzed for NO3 - -N concentrations using the colorimetric method, and fecal coliforms using the Most Probable Number (MPN) method. Based on this information, we will be able better positioned to assess agricultural impacts on water resources which will help towards the development on industry accepted farming practices. (author)

  14. Arterial Pulsations cannot Drive Intramural Periarterial Drainage: Significance for Aβ Drainage

    Directory of Open Access Journals (Sweden)

    Alexandra K. Diem

    2017-08-01

    Full Text Available Alzheimer's Disease (AD is the most common form of dementia and to date there is no cure or efficient prophylaxis. The cognitive decline correlates with the accumulation of amyloid-β (Aβ in the walls of capillaries and arteries. Our group has demonstrated that interstitial fluid and Aβ are eliminated from the brain along the basement membranes of capillaries and arteries, the intramural periarterial drainage (IPAD pathway. With advancing age and arteriosclerosis, the stiffness of arterial walls, this pathway fails in its function and Aβ accumulates in the walls of arteries. In this study we tested the hypothesis that arterial pulsations drive IPAD and that a valve mechanism ensures the net drainage in a direction opposite to that of the blood flow. This hypothesis was tested using a mathematical model of the drainage mechanism. We demonstrate firstly that arterial pulsations are not strong enough to produce drainage velocities comparable to experimental observations. Secondly, we demonstrate that a valve mechanism such as directional permeability of the IPAD pathway is necessary to achieve a net reverse flow. The mathematical simulation results are confirmed by assessing the pattern of IPAD in mice using pulse modulators, showing no significant alteration of IPAD. Our results indicate that forces other than the cardiac pulsations are responsible for efficient IPAD.

  15. Drainage under increasing and changing requirements

    NARCIS (Netherlands)

    Schultz, E.; Zimmer, D.; Vlotman, W.F.

    2007-01-01

    This year the Working Group on Drainage of the International Commission on Irrigation and Drainage (ICID) celebrates its 25th anniversary. This paper reviews the development of drainage for three different agro-climatic zones, i.e. the temperate (humid), the arid/semi-arid and the humid/semi-humid

  16. Sanitary surveillance and bioethics

    Directory of Open Access Journals (Sweden)

    Volnei Garrafa

    2017-08-01

    Full Text Available Regulatory practices in the field of health surveillance are indispensable. The aim of this study is to show ‒ taking the Brazilian National Surveillance Agency, governing body of sanitary surveillance in Brazil as a reference ‒ that bioethics provides public bodies a series of theoretical tools from the field of applied ethics for the proper exercise and control of these practices. To that end, the work uses two references of bioethics for the development of a comparative and supportive analysis to regulatory activities in the field of health surveillance: the Universal Declaration on Bioethics and Human Rights of Unesco and the theory of intervention bioethics. We conclude that organizations and staff working with regulatory activities can take advantage of the principles and frameworks proposed by bioethics, especially those related to the Declaration and the theory of intervention bioethics, the latter being set by the observation and use of the principles of prudence, precaution, protection and prevention.

  17. Interim sanitary landfill groundwater monitoring report. 1996 Annual report

    International Nuclear Information System (INIS)

    Bagwell, L.A.

    1997-01-01

    Eight wells of the LFW series monitor groundwater quality in the Steed Pond Aquifer (Water Table) beneath the Interim Sanitary Landfill at the Savannah River Site. These wells are sampled semiannually to comply with the South Carolina Department of Health and Environmental Control Modified Municipal Solid Waste Permit 025500-1120 and as part of the SRS Groundwater Monitoring Program. Trichlorofluoromethane and 1,1,1-trichloroethane were elevated in one sidegradient well and one downgradient well during 1996. Zinc was elevated in three downgradient wells and also was detected in the associated laboratory blanks for two of those wells. Specific conductance was elevated in one background well and one sidegradient well. Barium and copper exceeded standards in one sidegradient well, and dichloromethane (a common laboratory contaminant) was elevated in another sidegradient well. Barium, copper, and dichloromethane were detected in the associated blanks for these wells, also. The groundwater flow direction in the Steed Pond Acquifer (Water Table) beneath the Interim Sanitary Landfill was to the southeast (universal transverse Mercator coordinates). The flow rate in this unit was approximately 210 ft/year during first quarter 1996 and 180 ft/yr during third quarter 1996

  18. Sanitary landfill groundwater monitoring report. Fourth quarter 1994 and 1994 summary

    International Nuclear Information System (INIS)

    1995-02-01

    Eighty-nine wells of the LFW series monitor groundwater quality in the Steed Pond Aquifer (Water Table) beneath the Sanitary Landfill at the Savannah River Site (SRS). These wells are sampled quarterly to comply with the South Carolina Department of Health and Environmental Control Domestic Waste Permit DWP-087A and as part of the SRS Groundwater Monitoring Program. Dichloromethane, a common laboratory contaminant, and trichloroethylene were the most widespread constituents exceeding standards during 1994. Benzene, chloroethene (vinyl chloride), 1,2-dichloroethane, 1,1-dichloroethylene, 1,2-dichloropropane, gross alpha, mercury, nonvolatile beta, tetrachloroethylene, and tritium also exceeded standards in one or more wells. The groundwater flow direction in the Steed Pond Aquifer (Water Table) beneath the Sanitary Landfill was to the southeast (universal transverse Mercator coordinates). The flow rate in this unit was approximately 140 ft/year during first and fourth quarters 1994

  19. Social impact assessment of subsurface drainage

    International Nuclear Information System (INIS)

    Azhar, A.H.; Rafiq, M.; Alam, M.M.

    2005-01-01

    Social impact assessment of four drainage projects namely; Mardan SCARP Project (MSP), Fourth Drainage Project, Faisalabad (FDP), Chashma Command Area Development Project (CCADP) and Mirpurkhas Tile Drainage Project (MKOP) has been done. For this purpose, a socio-technical survey was carried out in which randomly selected farmers were interviewed. The investigations revealed that although significant population (-77%) at four study sites was educated, yet, the farmers were not satisfactorily educated to understand the operation and maintenance of drainage systems. The perusal of data revealed that 14%, 17% and 25% respondents from MSP, FOP and MKDP respectively had to migrate from their villages mainly due to pre-project water logging problem. However, installation of drainage systems in those areas improved the situation resulting in the increase of farm income, which was an attraction for them to return to their villages. The analysis of farm mechanization revealed that at MSP, FDP, CCADP and MKOP sites 71%, 42%, 40% and 75% respondents respectively were tractor owners and owners of some kind of other farm implements, whereas, remaining respondents were performing their farm operations on hire basis. Although, hire operation basis is much better than traditional ways, however, improving the farm mechanization could further enhance the benefits of drainage systems. The investigations revealed that a significant majority of respondents at four project sites had never met the Agricultural Extension Officer. The farmers' access to financing institutions such as ZTB was also negligible. There was lack of coordination among various departments such as WAPDA, Agriculture Extension and Irrigation and Power Department at four study sites. Nevertheless, the overall social impact investigations did reveal that the objectives of drainage systems installation have been achieved in terms of uplifting the socio-economic conditions of drainage areas. To make the efficient use of

  20. The sanitary approach: risk assessment according to the usable drainage techniques; L'approche sanitaire: evaluation des risques selon les techniques d'evacuation utilisables

    Energy Technology Data Exchange (ETDEWEB)

    Mouthon, G. [Ecole Nationale Veterinaire d' Alfort, 94 - Maison-Alfort (France)

    2003-02-01

    Sludges are by-products of waste water processing facilities. These sludges contain organic matter which can be valorized in agriculture, but they also contain microorganisms (parasites, bacteria, viruses, prions, dioxines), noxious compounds like heavy metals and persistent organic micro-pollutants. Valorization processes are developed to reduce the sanitary and environmental risks of sludges which are reviewed in this article: metal micro-pollutants (origin, physico-chemical state, transfer in the soil, accumulation in plants and soils, remobilization by erosion, French legislation about trace elements content); organic micro-pollutants (nature, public health risks, transfer in plants and environments, regulation); pathogenic microorganisms in sludges (content, abatement by spreading); valorization of urban and industrial sludges (disposal, spreading in agriculture, heavy metals elimination using Ondeo's 'Metix' process, incineration and valorization of combustion products); other valorization ways (biogas production, use as fuel for cement plants, phosphorous extraction). (J.S.)

  1. Interim Sanitary Landfill Groundwater Monitoring Report. 1997 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    Eight wells of the LFW series monitor groundwater quality in the Steed Pond Aquifer (Water Table) beneath the Interim Sanitary Landfill at the Savannah River Site (SRS). These wells are sampled semiannually to comply with the South Carolina Department of Health and Environmental Control Modified Municipal Solid Waste Permit 025500-1120 (formerly dWP-087A) and as part of the SRS Groundwater Monitoring Program.

  2. Sanitary and hygienic state estimation of population determined by cancer morbidity level

    International Nuclear Information System (INIS)

    Coretchi, L.; Cucereanu, A.

    2009-01-01

    The European recommendations of Cancer Register elaboration are presented in this paper. A short literature review about sanitary and hygienic estimation status of population thru determination of cancer morbidity level also has been performed. (authors)

  3. Inventory of drainage wells and potential sources of contaminants to drainage-well inflow in Southwest Orlando, Orange County, Florida

    Science.gov (United States)

    Taylor, George Fred

    1993-01-01

    Potential sources of contaminants that could pose a threat to drainage-well inflow and to water in the Floridan aquifer system in southwest Orlando, Florida, were studied between October and December 1990. Drainage wells and public-supply wells were inventoried in a 14-square-mile area, and available data on land use and activities within each drainage well basin were tabulated. Three public-supply wells (tapping the Lower Floridan aquifer) and 38 drainage wells (open to the Upper Floridan aquifer) were located in 17 drainage basins within the study area. The primary sources of drainage-well inflow are lake overflow, street runoff, seepage from the surficial aquifer system, and process-wastewater disposal. Drainage-well inflow from a variety of ares, including resi- dential, commercial, undeveloped, paved, and industrial areas, are potential sources of con- taminants. The four general types of possible contaminants to drainage-well inflow are inorganic chemicals, organic compounds, turbidity, and microbiological contaminants. Potential contami- nant sources include plant nurseries, citrus groves, parking lots, plating companies, auto- motive repair shops, and most commonly, lake- overflow water. Drainage wells provide a pathway for contaminants to enter the Upper Floridan aquifer and there is a potential for contaminants to move downward from the Upper Floridan to the Lower Floridan aquifer.

  4. Hygienic-sanitary profile and microbiological dangers in public slaughterhouses

    Directory of Open Access Journals (Sweden)

    Edinaidy Suianny Rocha de Moura

    2015-10-01

    Full Text Available ABSTRACT. Moura E.S.R., Abrantes M.R., Mendes C.G., Oliveira A.R.M, Souza E.S. & Silva J.B.A. [Hygienic-sanitary profile and microbiological dangers in public slaughterhouses.] Perfil higiênico-sanitário e perigos microbiológicos em abatedouros públicos. Revista Brasileira de Medicina Veterinária, 37(3:203-208, 2015. Departamento de Ciência Animal, Universidade Federal Rural do Semi-Árido, Avenida Francisco Mota, 572, Bairro Costa e Silva, Mossoró, RN 59625-900, Brasil. E-mail: jeanberg@ufersa.edu.br The aim of this study was to evaluate hygienic and sanitary conditions of municipal slaughterhouses in Rio Grande do Norte. Through a check list, hygienic conditions of establishments and handlers were observed and the percentage of compliance was rated excellent (≥ 80%, good (60 to 79.9%, regular (40 to 59.9% and poor (<40%, according to official standards established by Brazilian legislation. Ten water samples were collected to analyze total and thermotolerant coliforms; and 200 swab samples, including 150 from the utensils, equipment, handlers, and cattle carcasses were investigated for Staphylococcus aureus and Enterobacteria, and 50 from the environment for Listeria sp. research. It was noted, through the check list, the existence of various inadequate parameters when compared to those established, and required by law. According to the percentage of compliance found in abattoirs during the assessment visits, no slaughterhouse was rated as excellent, only one was considered good, one was classified as regular and three were considered poor. As for the microbiological analyzes, the presence of coliforms was confirmed in water from two slaughterhouses. High bacteria counts were found in swabs from tools, handlers, and cattle carcasses, and the presence of Listeria sp. was observed in three slaughterhouses. Therefore, the precarious sanitary conditions of the municipal slaughterhouses studied in Rio Grande do Norte represent a risk to

  5. Wound Drainage Culture (For Parents)

    Science.gov (United States)

    ... Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Wound Drainage Culture KidsHealth / For Parents / Wound Drainage Culture What's in ...

  6. [The senses of sanitary safety in the discourse of the National Health Surveillance Agency].

    Science.gov (United States)

    Barbosa, Ana de Oliveira; Costa, Ediná Alves

    2010-11-01

    The term sanitary safety (SS) appeared in the international debate mainly due to the emerging sanitary crisis, although its meaning has remained obscure. This paper aims to analyze the concept of SS brought into the Brazilian sanitary surveillance upon the creation of the National Health Surveillance Agency. An exploratory case study was undertaken with technical data analysis and semi-structured interviews with informants who had taken part in the process of formulating the body's institutional design. The following categories were analyzed: incorporation of the SS term into the institutional mission, the SS concept and SS mechanisms. The SS concept was analyzed in both institutional and technical discursive dimensions. The former elicits the sense of strategy, a reliable relationship and legitimacy whereas the latter shows the sense of an acceptable risk-benefit relationship from the perspective of individual and collective health protection and promotion. The SS concept was found to encompass health-related products, technologies and services, especially those designed for medical diagnosis and treatment, but environmental issues received little mention. The scope of the SS concept was shown to be widening to include the surveillance of hospital infection, drugs and blood.

  7. RESULTS AND PROSPECTS OF SANITARY AND EPIDEMIOLOGICAL WELL-BEING ENSURING FOR THE POPULATION OF RUSSIAN FEDERATION

    Directory of Open Access Journals (Sweden)

    G. G. Onischenko

    2008-01-01

    Full Text Available The report states priority goals of sanitary and epidemiological service and shows the analysis of the Service's administrative reforms and structural changes from 1991 to 2007. It considers the existing regulatory and legal background on all aspects of hygiene and epidemiology as well as the Concept of the Federal Service Development. It analyses the work of Rospotrebnadzor  bodies in ensuring of sanitary and epidemiological well-being of the population, including current state of population radiation protection in Russian Federation.

  8. Pre-operative biliary drainage for obstructive jaundice

    Science.gov (United States)

    Fang, Yuan; Gurusamy, Kurinchi Selvan; Wang, Qin; Davidson, Brian R; Lin, He; Xie, Xiaodong; Wang, Chaohua

    2014-01-01

    Background Patients with obstructive jaundice have various pathophysiological changes that affect the liver, kidney, heart, and the immune system. There is considerable controversy as to whether temporary relief of biliary obstruction prior to major definitive surgery (pre-operative biliary drainage) is of any benefit to the patient. Objectives To assess the benefits and harms of pre-operative biliary drainage versus no pre-operative biliary drainage (direct surgery) in patients with obstructive jaundice (irrespective of a benign or malignant cause). Search methods We searched the Cochrane Hepato-Biliary Group Controlled Trials Register, Cochrane Central Register of Controlled Clinical Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until February 2012. Selection criteria We included all randomised clinical trials comparing biliary drainage followed by surgery versus direct surgery, performed for obstructive jaundice, irrespective of the sample size, language, and publication status. Data collection and analysis Two authors independently assessed trials for inclusion and extracted data. We calculated the risk ratio (RR), rate ratio (RaR), or mean difference (MD) with 95% confidence intervals (CI) based on the available patient analyses. We assessed the risk of bias (systematic overestimation of benefit or systematic underestimation of harm) with components of the Cochrane risk of bias tool. We assessed the risk of play of chance (random errors) with trial sequential analysis. Main results We included six trials with 520 patients comparing pre-operative biliary drainage (265 patients) versus no pre-operative biliary drainage (255 patients). Four trials used percutaneous transhepatic biliary drainage and two trials used endoscopic sphincterotomy and stenting as the method of pre-operative biliary drainage. The risk of bias was high in all trials. The proportion of patients with malignant obstruction varied between 60

  9. NORTH PORTAL - SANITARY SEWER CALCULATION - CHANGE HOUSE FACILITY No.5008

    International Nuclear Information System (INIS)

    Blackstone, R.

    1996-01-01

    The purpose of this design calculation is to determine the demand on the waste system and to size the three main sanitary sewer lines serving the Change House Facility No.5008, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2)

  10. The health of hospitals and lessons from history: public health and sanitary reform in the Dublin hospitals, 1858-1898.

    Science.gov (United States)

    Fealy, Gerard M; McNamara, Martin S; Geraghty, Ruth

    2010-12-01

    The aim was to examine, critically, 19th century hospital sanitary reform with reference to theories about infection and contagion. In the nineteenth century, measures to control epidemic diseases focused on providing clean water, removing waste and isolating infected cases. These measures were informed by the ideas of sanitary reformers like Chadwick and Nightingale, and hospitals were an important element of sanitary reform. Informed by the paradigmatic tradition of social history, the study design was a historical analysis of public health policy. Using the methods of historical research, documentary primary sources, including official reports and selected hospital archives and related secondary sources, were consulted. Emerging theories about infection were informing official bodies like the Board of Superintendence of Dublin Hospitals in their efforts to improve hospital sanitation. The Board secured important reforms in hospital sanitation, including the provision of technically efficient sanitary infrastructure. Public health measures to control epidemic infections are only as effective as the state of knowledge of infection and contagion and the infrastructure to support sanitary measures. Today, public mistrust about the safety of hospitals is reminiscent of that of 150 years ago, although the reasons are different and relate to a fear of contracting antimicrobial-resistant infections. A powerful historical lesson from this study is that resistance to new ideas can delay progress and improved sanitary standards can allay public mistrust. In reforming hospital sanitation, policies and regulations were established--including an inspection body to monitor and enforce standards--the benefits of which provide lessons that resonate today. Such practices, especially effective independent inspection, could be adapted for present-day contexts and re-instigated where they do not exist. History has much to offer contemporary policy development and practice reform and

  11. Law no. 2001-398 of the 9 may 2001 creating a french Agency of sanitary and environmental safety (1)

    International Nuclear Information System (INIS)

    2001-05-01

    This law text indicates the goal and the missions of the french sanitary and environmental safety Agency, defined by the law no.2001-398: to assure the public health the Agency has to contribute to the the sanitary safety in the environment domain and to evaluate the risk bonded to the environment. (A.L.B)

  12. Advances in drainage: Selected works from the Tenth International Drainage Symposium

    Science.gov (United States)

    Strock, Jeffrey S.; Hay, Christopher; Helmers, Matthew; Nelson, Kelly A.; Sands, Gary R.; Skaggs, R. Wayne; Douglas-Mankin, Kyle R.

    2018-01-01

    This article introduces a special collection of fourteen articles accepted from among the 140 technical presentations, posters, and meeting papers presented at the 10th International ASABE Drainage Symposium. The symposium continued in the tradition of previous symposia that began in 1965 as a forum for presenting and assessing the progress of drainage research and implementation throughout the world. The articles in this collection address a wide range of topics grouped into five broad categories: (1) crop response, (2) design and management, (3) hydrology and scale, (4) modeling, and (5) water quality. The collection provides valuable information for scientists, engineers, planners, and others working on crop production, water quality, and water quantity issues affected by agricultural drainage. The collection also provides perspectives on the challenges of increasing agricultural production in a changing climate, with ever-greater attention to water quality and quantity concerns that will require integrated technical, economic, and social solutions.

  13. [Ascites drainage at home].

    Science.gov (United States)

    Lutjeboer, Jacob; van Erkel, Arian R; van der Hoeven, J J M Koos; van der Meer, Rutger W

    2015-01-01

    Ascites can lead to many symptoms, and often occurs in patients with an end-stage malignancy such as ovarian, pancreatic, colonic, or gastric cancer. Intermittent ascites drainage is applied in these patients as a palliative measure. As frequent drainage is necessary, a subcutaneously tunnelled permanent ascites catheter is a good alternative for intermittent drainage. The patient can open - and then re-close - the catheter when abdominal pressure increases. We inserted 35 subcutaneously permanent ascites catheters in the course of the past 3.5 years in the Leiden University Medical Centre. The success rate was 100% and the complication risk was 2.9%. A subcutaneously tunnelled ascites catheter is an effective and safe palliative treatment for patients with end-stage malignant disease and suffering from ascites.

  14. Failures and complications of thoracic drainage

    Directory of Open Access Journals (Sweden)

    Đorđević Ivana

    2006-01-01

    Full Text Available Background/Aim. Thoracic drainage is a surgical procedure for introducing a drain into the pleural space to drain its contents. Using this method, the pleura is discharged and set to the physiological state which enables the reexpansion of the lungs. The aim of the study was to prove that the use of modern principles and protocols of thoracic drainage significantly reduces the occurrence of failures and complications, rendering the treatment more efficient. Methods. The study included 967 patients treated by thoracic drainage within the period from January 1, 1989 to June 1, 2000. The studied patients were divided into 2 groups: group A of 463 patients treated in the period from January 1, 1989 to December 31, 1994 in whom 386 pleural drainage (83.36% were performed, and group B of 602 patients treated form January 1, 1995 to June 1, 2000 in whom 581 pleural drainage (96.51% were performed. The patients of the group A were drained using the classical standards of thoracic drainage by the general surgeons. The patients of the group B, however, were drained using the modern standards of thoracic drainage by the thoracic surgeons, and the general surgeons trained for this kind of the surgery. Results. The study showed that better results were achieved in the treatment of the patients from the group B. The total incidence of the failures and complications of thoracic drainage decreased from 36.52% (group A to 12.73% (group B. The mean length of hospitalization of the patients without complications in the group A was 19.5 days versus 10 days in the group B. The mean length of the treatment of the patients with failures and complications of the drainage in the group A was 33.5 days versus 17.5 days in the group B. Conclusion. The shorter length of hospitalization and the lower morbidity of the studied patients were considered to be the result of the correct treatment using modern principles of thoracic drainage, a suitable surgical technique, and a

  15. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): design and rationale of a randomized controlled trial.

    Science.gov (United States)

    Wiggers, Jimme K; Coelen, Robert J S; Rauws, Erik A J; van Delden, Otto M; van Eijck, Casper H J; de Jonge, Jeroen; Porte, Robert J; Buis, Carlijn I; Dejong, Cornelis H C; Molenaar, I Quintus; Besselink, Marc G H; Busch, Olivier R C; Dijkgraaf, Marcel G W; van Gulik, Thomas M

    2015-02-14

    Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when severe drainage-related complications deteriorate the patients' condition or increase the risk of postoperative morbidity. Biliary drainage can cause cholangitis/cholecystitis, pancreatitis, hemorrhage, portal vein thrombosis, bowel wall perforation, or dehydration. Two methods of preoperative biliary drainage are mostly applied: endoscopic biliary drainage, which is currently used in most regional centers before referring patients for surgical treatment, and percutaneous transhepatic biliary drainage. Both methods are associated with severe drainage-related complications, but two small retrospective series found a lower incidence in the number of preoperative complications after percutaneous drainage compared to endoscopic drainage (18-25% versus 38-60%, respectively). The present study randomizes patients with potentially resectable PHC and biliary obstruction between preoperative endoscopic or percutaneous transhepatic biliary drainage. The study is a multi-center trial with an "all-comers" design, randomizing patients between endoscopic or percutaneous transhepatic biliary drainage. All patients selected to potentially undergo a major liver resection for presumed PHC are eligible for inclusion in the study provided that the biliary system in the future liver remnant is obstructed (even if they underwent previous inadequate endoscopic drainage). Primary outcome measure is the total number of severe preoperative complications between randomization and exploratory laparotomy. The study is designed to detect superiority of percutaneous drainage: a provisional sample size of 106 patients is required to detect a relative decrease of 50% in the number of severe preoperative

  16. Sanitary hot water consumption patterns in commercial and industrial sectors in South Africa: Impact on heating system design

    International Nuclear Information System (INIS)

    Rankin, R.; Rousseau, P.G.

    2006-01-01

    A large amount of individual sanitary hot water consumers are present in the South African residential sector. This led to several studies being done on hot water consumption patterns in this sector. Large amounts of sanitary hot water are also consumed in the commercial sector in buildings such as hotels and in large residences such as those found in the mining industry. The daily profiles of sanitary hot water consumption are not related to any technical process but rather to human behavior and varying ambient conditions. The consumption of sanitary hot water, therefore, represents a challenge to the electrical utility because it is an energy demand that remains one of the biggest contributors to the undesirable high morning and afternoon peaks imposed on the national electricity supply grid. It also represents a challenge to sanitary hot water system designers because the amount of hot water as well as the daily profile in which it is consumed impacts significantly on system design. This paper deals with hot water consumption in the commercial and industrial sectors. In the commercial sector, we look at hotels and in the industrial sector at large mining residences. Both of them are served by centralized hot water systems. Measured results from the systems are compared to data obtained from previous publications. A comparison is also made to illustrate the impact that these differences will have on sanitary hot water system design. Simulations are conducted for these systems using a simulation program developed in previous studies. The results clearly show significant differences in the required heating and storage capacity for the new profiles. A twin peak profile obtained from previous studies in the residential sector was used up to now in studies of heating demand and system design in commercial buildings. The results shown here illustrate the sanitary hot water consumption profile differs significantly from the twin peaks profile with a very high morning

  17. Design of manuals sanitary landfills (II). Diseo de rellenos sanitarios manuales (II)

    Energy Technology Data Exchange (ETDEWEB)

    Jaramillo, J.

    1994-01-01

    This period includes engineering projects, landscape and details of building; taking into account the circumstances that govern them, it must be made looking at the simplicity and quickness required to these type of works and trying to respect sanitary requirements. (Author)

  18. The sanitary effect of gamma irradiation on sewage sludge

    International Nuclear Information System (INIS)

    Hess, E.; Breer, C.

    1975-01-01

    Sludge contains Salmonellae in more than 90% of samples. The maximum number reaches 10 7 per liter. Neither aerobic stabilization nor anaerobic digestion significantly reduces the contamination with Salmonellae. Moreover, Salmonellae in sewage sludge spread on grass may survive up to 72 weeks. Fertilizing with unsanitized sludge may therefore lead to transmission from plant to animal. Sanitizing of sludge to be used as fertilizer is therefore urgent. The sanitary effect of pasteurisation and of gamma irradiation on sewage sludge was investigated. For this the number of Enterobacteriaceae before and after irradiation in 259 specimens of sludge from 44 different sewage disposal plants was examined. The doses applied were 100, 200, 300, 400 and sometimes 500 krad. A linear reduction of Enterobacteriaceae was achieved with increasing radiation doses. A dose of 300 krad resulted in a death rate of 10 4 - 10 8 , occasionally 10 9 Enterobacteriaceae. Less than 10 Enterobacteriaceae per gramm were found in 97.2% of the samples irradiated with 300 krad. The effect found in the above mentioned model experiments could be perfectly confirmed under practical conditions in the irradiation plant of Geiselbullach. The sanitary effect of gamma irradiation with 300-350 krad, determined by Enterobacteriaceae reduction, was equivalent to the effect of heat treatment by pasteurisation. (orig./MG) [de

  19. MATERIALS FOR THE FINAL COVER OF SANITARY LANDFILLS

    OpenAIRE

    Davorin Kovačić

    1994-01-01

    The paper deals with the selection of materials for the sea¬ling layer in the final cover of sanitary landfills. The sealing la¬yer is the most critical component of the final cover. Its role is to minimize percolation of water through the final cover. Ma¬terials used for the construction of the sealing layer are either of mineral origin (compacted clay) or geosynthetic (geomem¬brane). They are most often used in combination creating com¬posite liners. Recently alternative materials are also ...

  20. Acid drainage (AD) in nature and environmental impact of acid mine drainage (AMD) in Southern Tuscany

    International Nuclear Information System (INIS)

    Di Lella, Luigi Antonello; Protano, Giuseppe; Riccobono, Francesco

    2005-01-01

    Acid drainage (AD) is a natural process occurring locally at the Earth's surface. It consists in a substantial increase of acidity of surface waters as a result of chemical reactions occurring in the atmosphere (i.e. acid rain) or involving reactive phases (i.e. pyrite) present in the percolated medium. Acidic surface waters (usually pH < 4) can be produced by oxidation of sulphides (mainly pyrite and other iron sulphides) exposed to atmospheric oxygen, while human activities, such as mining, can greatly enhance this process. Acid drainage promoted by mining activities is called acid mine drainage (AMD) and is a primary source of environmental pollution and a world-wide problem in both active and abandoned mining areas. In fact, exposure of iron sulphides to oxidising conditions produces strongly acidic drainage waters rich in sulphate and a variety of heavy elements (i.e. As, Cd, Pb, Sb). Several occurrences of active acid mine drainage have been found in the Metalliferous Hills (southern Tuscany). The most important AMD phenomena were observed in the Fenice Capanne and Niccioleta mining areas

  1. The process of biosorption of heavy metals in bioreactors loaded with sanitary sewage sludge

    Directory of Open Access Journals (Sweden)

    A. J. Morais Barros

    2006-06-01

    Full Text Available This work on the process of biosorption of nickel and chromium in an ascendant continuous-flow, fixed packed-bed bioreactor of sanitary sewage sludge was conducted in a search for solutions to the environmental problem caused by heavy metals. Analysis of the results demonstrated that the absorbent had an extraordinary capacity for biosorption of the heavy metals studied at about 9.0 pH of the effluent, with a removal percentage of over 90.0% for the two metals. Chemometric study results demonstrated that 20 days of the experimental system function were sufficient for achieving the maximum efficiency of sorption of the heavy metals studied by the sanitary sewage sludge employed.

  2. Percutaneous drainage of abscesses associated with biliary fistulae

    International Nuclear Information System (INIS)

    Berger, H.; Winter, T.; Pratschke, E.; Sauerbruch, T.; Klinikum Grosshadern, Muenchen; Klinikum Grosshadern, Muenchen

    1989-01-01

    33 abdominal abscesses associated with fistulae in 31 patients were treated by percutaneous drainage. 19 of these patients had had surgery immediately preceding the drainage. In 64% the percutaneous drainage led to a diagnosis of an internal fistula. Additional therapeutic measures, because of the fistula, were necessary in 45% (operation, biliary drainage, repositioning of catheter). The average duration of drainage was 29 days. 77% of those abscesses which could be drained were treated successfully. Mortality in the entire series was 19%. (orig.) [de

  3. Reuse of drainage water in the Nile Delta; monitoring, modelling and analysis; final report Reuse of Drainage Water Project

    NARCIS (Netherlands)

    Staring Centrum, Instituut voor Onderzoek van het LandelijkGebied

    1995-01-01

    The effects of reusing drainage water have been evaluated and other options to increase the water utilization rate in Egypt explored. The results are an operational network for monitoring drainage water discharges and salinity along the major drains, a database for monitored drainage water

  4. Biogas movements in sanitary landdfills; Movimiento de biogas en rellenos sanitarios

    Energy Technology Data Exchange (ETDEWEB)

    Vidales A, Humberto

    1988-12-31

    This paper shows a model to study the physical and kinetic equations that determine the movement and diffusion of the biogas in sanitary landfills. This model for biogas flow was made in function of pressure, temperature, waste porosity and permeability, due to a diffusion coefficient of biogas determination 6 refs., 4 figs.

  5. Prospective technologies and equipment for sanitary hygienic measures for life support systems

    Science.gov (United States)

    Shumilina, I. V.

    Creation of optimal sanitary hygienic conditions is a prerequisite for good health and performance of crews on extended space missions. There is a rich assortment of associated means, methods and equipment developed and experimentally tested in orbital flights. However, over a one-year period a crew of three uses up about 800 kg of ground-supplied wet wipes and towels for personal needs. The degree of closure of life support systems for long-duration orbital flights should be maximized, particularly for interplanetary missions, which exclude any possibility of re-supply. Washing with regenerated water is the ultimate sanitary hygienic goal. That is why it is so important to design devices for crew bathing during long-term space missions. Investigations showed that regeneration of wash water (WW) using membrane processes (reverse osmosis, nanofiltration etc.), unlike sorption, would not require much additional expendables. A two-stage membrane recovery unit eliminated >85% of permeate from real WW with organic and inorganic selectivity of 82 95%. The two-stage WW recovery unit was tested with artificial and real WW containing detergents available for space crews. Investigations into the ways of doing laundry and drying along with which detergents will be the best fit for space flight are also planned. Testing of a technology for water extraction from used textiles using a conventional period of contact of 1 s or more, showed that the humidity of the outgoing air flow neared 100%. Issues related to designing the next generation of space life support systems should consider the benefits of integrating new sanitary hygienic technologies, equipment, and methods.

  6. Sanitary-hygienic and ecological aspects of beryllium production

    Energy Technology Data Exchange (ETDEWEB)

    Dvinskykh, E.M.; Savchuk, V.V.; Sidorov, V.L.; Slobodin, D.B.; Tuzov, Y.V. [Ulba Metallurgical Plant, Ust-Kamenogorsk (Kazakhstan)

    1998-01-01

    The Report describes An organization of sanitary-hygienic and ecological control of beryllium production at Ulba metallurgical plant. It involves: (1) the consideration of main methods for protection of beryllium production personnel from unhealthy effect of beryllium, (2) main kinds of filters, used in gas purification systems at different process areas, (3) data on beryllium monitoring in water, soil, on equipment. This Report also outlines problems connected with designing devices for a rapid analysis of beryllium in air as well as problems of beryllium production on ecological situation in the town. (author)

  7. [Pesticide exposure and its repercussion in the health of sanitary agents in the State of Ceará, Brazil].

    Science.gov (United States)

    Lima, Estelita Pereira; Lopes, Suziy de Matos Bandeira; Amorim, Maria Iracema Mariano de; Araújo, Laura Helena Silva; Neves, Kelly Rose Tavares; Maia, Evanira Rodrigues

    2009-01-01

    Sanitary agents are the most exposed ones to the effects of insecticides in eradication campaigns since its preparation until its application inside and outside houses. The lack of protection equipment and misinformation on how to use the material properly increase the risk of intoxication. The aim of this work was to analyze the occupational history of vector control sanitary agents in Ceará State, Brazil and its effects on their health. Individual recorded interviews were done with 10 agents who verbally described their life history. The content of these interviews were analyzed through the following categories: agent profile, endemic controls, work conditions, risks and health changes. Health risk situations were described from acute and chronic intoxication to problems with alcoholism. The research showed that sanitary agents have been disrespected as human beings as well as their labor rights, showing negligence by their employers.

  8. Radiologically-guided catheter drainage of intrathoracic abscesses and empyemas

    International Nuclear Information System (INIS)

    Berger, H.; Steiner, W.; Bergman, C.; Anthuber, M.; Dienemann, H.

    1993-01-01

    Radiologically guided percutaneous catheter drainage was used in 38 patients to treat pleural empyemas (35 patients) and pulmonary abscesses (3 patients). Drainage was successful in 85.7% of empyemas including 11 cases with fistulous communications. Three percutaneously drained pulmonary abscesses required subsequent lobectomy. One patient died during the drainage procedure due to sepsis. No major complications related to the drainage procedure were observed. Guided percutaneous drainage proved to be a safe and successful alternative to closed drainage of pleural fluid collections. (orig.)

  9. Percutaneous drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Ri, Jong Min; Kim, Yong Joo; Kang, Duk Sik [Kyung-Pook National University Hospital, Daegu (Korea, Republic of)

    1992-05-15

    Medical treatment using antibiotics and postural drainage has been widely adopted as a treatment method of pulmonary abscess, accompanied by surgical methods in cases intractable to drug therapy. However long-term therapy may be required, and the tolerance of organisms to antibiotics or other complications are apt to be encountered, during medical treatment. To shorten the convalescent period or to decrease the risk of invasive procedures, rather simple and relatively easy interventional techniques such as transbronchial or percutaneous catheter drainage have been successfully tried. We have performed 12 cases of percutaneous drainages of lung abscesses under fluoroscope guidance. This report is on the results of this procedure.

  10. Percutaneous drainage of lung abscess

    International Nuclear Information System (INIS)

    Ri, Jong Min; Kim, Yong Joo; Kang, Duk Sik

    1992-01-01

    Medical treatment using antibiotics and postural drainage has been widely adopted as a treatment method of pulmonary abscess, accompanied by surgical methods in cases intractable to drug therapy. However long-term therapy may be required, and the tolerance of organisms to antibiotics or other complications are apt to be encountered, during medical treatment. To shorten the convalescent period or to decrease the risk of invasive procedures, rather simple and relatively easy interventional techniques such as transbronchial or percutaneous catheter drainage have been successfully tried. We have performed 12 cases of percutaneous drainages of lung abscesses under fluoroscope guidance. This report is on the results of this procedure

  11. Percutaneous drainage of diverticular abscess: Adjunct to resection

    International Nuclear Information System (INIS)

    Mueller, P.R.; Saini, S.; Butch, R.J.; Simeone, J.F.; Rodkey, G.V.; Bousquet, J.C.; Ottinger, L.W.; Wittenberg, J.; Ferrucci, J.T. Jr.

    1986-01-01

    Traditional surgical management of acute diverticulitis with abscess may require a one-, two-, or three-stage procedure. Because of recent interest in CT diagnosis of diverticulitis, and novel access routes for interventional drainage of deep pelvic abscesses, the authors investigated the potential for converting complex two- and three-stage surgical procedures to simpler, safer one-stage colon resections by percutaneous drainage of the associated abscess. Of 23 patients with acute perforated diverticulitis who were referred for catheter drainage under radiologic guidance, successful catheter drainage and subsequent single-stage colon resection were carried out in 15. In three patients catheter drainage was unsuccessful and a multistage procedure was required. In three patients only percutaneous drainage was performed and operative intervention was omitted entirely

  12. Geohydrologic reconnaissance of drainage wells in Florida

    Science.gov (United States)

    Kimrey, J.O.; Fayard, L.D.

    1984-01-01

    Drainage wells are used to inject surface waters directly into an aquifer, or shallow ground waters directly into a deeper aquifer, primarily by gravity. Such wells in Florida may be grouped into two broad types: (1) surface-water injection wells, and (2) interaquifer connector wells. Drainage wells of the first type are further categorized as either Floridan aquifer drainage wells or Biscayne aquifer drainage wells. Floridan aquifer drainage wells are commonly used to supplement drainage for urban areas in karst terranes of central and north Florida. Data are available for 25 wells in the Ocala, Live Oak, and Orlando areas that allow comparison of the quality of water samples from these Floridan aquifer drainage wells with allowable contaminant levels. Comparison indicates that maximum contaminant levels for turbidity, color, and iron, manganese, and lead concentrations are equaled or exceeded in some drainage-well samples, and relatively high counts for coliform bacteria are present in most wells. Biscayne aquifer drainage wells are used locally to dispose of stormwater runoff and other surplus water in southeast Florida, where large numbers of these wells have been permitted in Dade and Broward Counties. The majority of these wells are used to dispose of water from swimming pools or to dispose of heated water from air-conditioning units. The use of Biscayne aquifer drainage wells may have minimal effect on aquifer potability so long as injection of runoff and industrial wates is restricted to zones where chloride concentrations exceed 1,500 milligrams per liter. Interaquifer connector wells are used in the phosphate mining areas of Polk and Hillsborough Counties, to drain mines and recharge the Floridan aquifer. Water-quality data available from 13 connector wells indicate that samples from most of these wells exceed standards values for iron concentration and turbidity. One well yielded a highly mineralized water, and samples from 6 of the other 12 wells exceed

  13. EFFECTIVENESS OF AUTOGENIC DRAINAGE VERSUS POSTURAL DRAINAGE ON OXYGEN SATURATION IN PATIENTS WITH CHRONIC BRONCHITIS WITH 15 MINUTES POST THERAPY

    OpenAIRE

    V. Kiran; Dr. Bhimasen .S; E. Mastanaiah; A. Thiruppathi

    2014-01-01

    Background: Patients with COPD will have more amount of secretions. To clear the secretions by using of different bronchial hygiene techniques like postural drainage and autogenic drainage technique, manual hyperventilation technique ,active cycle breathing technique .Hence in this study to compare the short-term effects of postural drainage with clapping (PD) and autogenic drainage (AD) on level of oxygen saturation in blood, and amount of sputum recovery. Methodology: The study was done ...

  14. Sanitary Landfill Groundwater Monitoring Report, Fourth Quarter 1999 and 1999 Summary

    International Nuclear Information System (INIS)

    Chase, J.

    2000-01-01

    A maximum of thirty eight-wells of the LFW series monitor groundwater quality in the Steed Pond Aquifer (Water Table) beneath the Sanitary Landfill Area at the Savannah River Site (SRS). These wells are sampled quarterly to comply with the South Carolina Department of Health and Environmental Control Domestic Water Permit DWP-087A and as part of the SRS Groundwater Monitoring Program. Iron (Total Recoverable), Chloroethene (Vinyl Chloride) and 1,1-Dichloroethane were the most widespread constituents exceeding the Final Primary Drinking Water Standards during 1999. Trichloroethylene, 1,1-Dichloroethylene, 1,2-Dichloroethane, 1,4-Dichlorobenzene, Aluminum (Total Recoverable), Benzene, cis-1,2-Dichloroethylene, Dichlorodifluoromethane, Dichloromethane (Methylene Chloride), Gross Alpha, Mercury (Total Recoverable), Nonvolatile Beta, Tetrachloroethylene, Total Organic Halogens, Trichlorofluoromethane, Tritium also exceeded standards in one or more wells. The groundwater flow direction in the Steed Pond Aquifer (Water Table) beneath the Sanitary Landfill is to the southeast (universal transverse Mercator coordinates). The flow rate in this unit was approximately 144.175 ft/year during first quarter 1999 and 145.27 ft/year during fourth quarter 1999

  15. Postoperative drainage in head and neck surgery.

    Science.gov (United States)

    Amir, Ida; Morar, Pradeep; Belloso, Antonio

    2010-11-01

    A major factor affecting patients' length of hospitalisation following head and neck surgery remains the use of surgical drains. The optimal time to remove these drains has not been well defined. A routine practice is to measure the drainage every 24 h and remove the drain when daily drainage falls below 25 ml. This study aims to determine whether drainage measurement at shorter intervals decreases the time to drain removal and hence the length of in-patient stays. A 6-month prospective observational study was performed. The inclusion criteria were patients who underwent head and neck surgery without neck dissection and had a closed suction drain inserted. Drainage rates were measured at 8-hourly intervals. Drains were removed when drainage-rate was ≤ 1 ml/h over an 8-h period. A total of 43 patients were evaluated. The highest drainage rate occurred in the first 8 postoperative hours and decreased significantly in the subsequent hours. The median drainage rates at 8, 16, 24, 32 and 40 postoperative hours were 3.375, 1, 0, 0 and 0 ml/h, respectively. Applying our new removal criteria of ≤ 1 ml/h drainage rate, the drains were removed in 22 (51%) patients at the 16th postoperative hour; 37 (86%) were removed by 24 h after operation. In comparison, only nine (20.9%) patients could potentially be discharged the day after surgery if previous criteria of ≤ 25 ml/24-h were used to decide on drain removal. Our 8-hourly drainage-rate monitoring has facilitated safe earlier discharge of an additional 28 (65%) patients on the day after surgery. This has led to improvement in patient care, better optimisation of hospital resources and resulted in positive economic implications to the department.

  16. 7 CFR Exhibit B to Subpart C of... - Site Development Design Requirements

    Science.gov (United States)

    2010-01-01

    ... to sanitary sewers. 2. Piped Drainage. Piped roof drainage from buildings shall be connected to..., continuous impervious strata of clay, hard-pan, or rock. The well shall be constructed so as to prevent the..., vitrified clay, or equivalent materials. d. The space between the casing or liner and the wall of the well...

  17. Cleaner mites: sanitary mutualism in the miniature ecosystem of neotropical bee nests.

    Science.gov (United States)

    Biani, Natalia B; Mueller, Ulrich G; Wcislo, William T

    2009-06-01

    Cleaning symbioses represent classic models of mutualism, and some bee mites are thought to perform cleaning services for their hosts in exchange for suitable environments for reproduction and dispersal. These mutual benefits, however, have not been rigorously demonstrated. We tested the sanitary role of bee mites by correlating mite loads with fungal contamination in natural nests of Megalopta genalis and Megalopta ecuadoria and by experimentally manipulating mite loads in artificial cells with developing brood. Field observations revealed significant correlations between the presence of mites and the absence of fungi inside the brood cells, as well as between the absence of mites and increased bee mortality. Likewise, experimental brood cells with mites have fewer fungal colonies than do cells without mites. Field observations and experimental manipulations, therefore, provide clear evidence of the sanitary effect of mites in nests of Megalopta bees. This bee-mite association constitutes one of the few examples of terrestrial cleaning mutualisms.

  18. Traditional Foley drainage systems--do they drain the bladder?

    Science.gov (United States)

    Garcia, Maurice M; Gulati, Shelly; Liepmann, Dorian; Stackhouse, G Bennett; Greene, Kirsten; Stoller, Marshall L

    2007-01-01

    Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

  19. Irregularidades sanitárias como marcador de risco à saúde: um desafio para a vigilância sanitária / Sanitary Disparities as risks markers health: a challenge to sanitary surveillance

    Directory of Open Access Journals (Sweden)

    Fernanda Pini Freitas

    2013-02-01

    Full Text Available O estudo, de caráter exploratório, do tipo levantamento retrospectivo, objetivou identifi car as irregularidades sanitárias nos estabelecimentos e equipamentos de assistência de alta complexidade e de interesse à saúde do município de Franca-SP, registradas no Sistema de Informação em Vigilância Sanitária, no período de agosto de 2008 a julho de 2009, como marcador de risco à saúde. Do total de 186 serviços, 59 (31,72% apresentaram irregularidades sanitárias, categorizadas em nove eixos: documentação, estrutura física, recursos humanos, qualidade de produtos, manutenção preventiva de equipamentos, processo de esterilização, resíduos de saúde, higienização do ambiente e equipamento de proteção individual; e 164 (88,17% apresentaram condições de baixo risco, 21 (11,29% de médio e um serviço apresentou risco alto. Os resultados demonstram que as irregularidades sanitárias podem comprometer a qualidade do serviço ou do produto oferecido e gerar riscos à saúde dos usuários, consumidores e trabalhadores. ---------------------------------------------------------------------------------------- This study, as an exploratory one, retrospective survey-type, aimed to identify the sanitary disparities in the high complexity facilities and assistance tools and concerned to Franca – SP heath, registered in the Sanitary Surveillance Information System, in August 2008 to July 2009 as risks markers to health. From the amount of 186 services, 58 (31,72% presented sanitary disparities, categorized into nine axes: documentation, physical frames, human resources, products qualities, tool’s preventive maintenance, sterilization process. Health waste, environment hygiene and individual protection equipments, 164 (88, 17% presented a law risk condition, 21 (11,29% are average, and only one presented a high risk level. Results shows that such sanitary disparities may comprise the service or the offered product quality and

  20. Proposal for the reinforcement of the environmental sanitary safety; Proposition pour un renforcement de la securite sanitaire environnementale

    Energy Technology Data Exchange (ETDEWEB)

    Grzegrzulka, O; Aschieri, A [Assemblee Nationale, 75 - Paris (France)

    1998-11-01

    Facing the context of the public reliance crisis, the sanitary risks bound to the environment became more and more important. This report asked by the first Minister of France, takes stock on the government policy in this domain and the today institutions. The first part defines the problematic of the sanitary risks bound to the environment, the second one shows the non adapted answer offered by the actual government and the last one proposes new procedures and actions.

  1. Eco-efficient concretes: the effects of using recycled ceramic material from sanitary installations on the mechanical properties of concrete.

    Science.gov (United States)

    Guerra, I; Vivar, I; Llamas, B; Juan, A; Moran, J

    2009-02-01

    The aim of this research was to investigate some of the physical and mechanical properties of concrete mixed under laboratory conditions, where different proportions of coarse aggregate materials were substituted by porcelain from sanitary installations. The results of the tests show that the concrete produced has the same mechanical characteristics as conventional concrete, thus opening a door to selective recycling of sanitary porcelain and its use in the production of concrete.

  2. Evolution of sanitary-epidemiological services in Poland in the years 1944-2014

    Directory of Open Access Journals (Sweden)

    Marek L. Grabowski

    2017-11-01

    The pre-accession preparation to the European Union (EU strongly accelerated the development of sanitary-epidemiological services in Poland. Polish accession to the European Union has promoted the implementation of the WHO document “Health for All in the 21st Century” and the reduction of “health inequalities”.

  3. Attitudes towards the Use of the Medical and Sanitary Services in Iran

    Science.gov (United States)

    Mohseni, Manouchehr

    1977-01-01

    Describes research methodology and findings of a survey in Iran to determine relationships between educational level, age, residence, and other variables involved in attitudes regarding the use of medical and sanitary services. Public health education is seen to be needed. For journal availability, see SO 506 019. (Author/AV)

  4. 30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... flush toilet facilities. 71.400 Section 71.400 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE... installations and at the surface worksites of such mine. (Note: Sanitary facilities at surface work areas of...

  5. Sanitary and Phytosanitary Measures: The Case of Mexican Avocados

    OpenAIRE

    Bakshi, Nishita

    2003-01-01

    This thesis examines the effects on demand, supply, imports, and prices of partial easing of sanitary and phytosanitary (SPS) barriers to trade in the U.S. market in the case of Mexican avocados. The SPS Agreement plays a role in the avocado market studied here through its implications for negotiations between countries that have not utilized the formal channels of the WTO for resolving disputes. A quarantine in place from 1914 until very recently banned entry of Mexican avocados into the...

  6. Water radiological sanitary control of Veracruz State

    International Nuclear Information System (INIS)

    Carreon G, E.; Vazquez C, J. A.; Aguilar P, M. del C.; Parissi C, A.

    2014-10-01

    This work is carried out in Veracruz State covering over 11 jurisdictions of the State (Panuco, Tuxpan, Poza Rica, Martinez de la Torre, Xalapa, Cordoba, Orizaba, Veracruz, Cosamaloapan, San Andres Tuxtla and Coatzacoalcos). The sampling was realized in a period from 2009 to 2013 analyzing home drinking water, supply sources and wells, the sampling was done by the sanitary checkers of different jurisdictions with approved methods and the methodology was validated at the State Laboratory of Public Health. 1637 samples were analyzed by counting equipment Tennelec Canberra series 5 and a gas supply system P-10 with calibration curves for alpha and gross beta. The results of measurements ranging from 0.07 to 0.25 Bq/L in the activity concentration gross alpha annual average, an gross beta were from 0.12 to 0.17 Bq/L in the activity concentration gross beta annual average, and with a concentration range of alpha activity up to 0.62 and a minimum 0.02, and the concentration of beta activity of a maximum value 1.54 and a minimum 0.02, taking also as resulted in five years of analysis only 1.16% of the analyzed samples (19 samples) showed a value of alpha activity concentration above the minimum detectable concentration and 62.43% (1022 samples) of the analyzed samples showed a value of beta activity concentration above the minimum detectable concentration, is also clear that the results of the sanitary jurisdictions of Panuco and Tuxpan not have corresponding activity values for the years 2009, 2011-2013 except 2010. We can conclude that the regular measurements of alpha and gross beta activity in water are invaluable for timely detection of radioactive contamination. (Author)

  7. Sanitary effect of gamma irradiation on sewage sludge

    International Nuclear Information System (INIS)

    Hess, E.; Breer, C.

    1975-01-01

    Our investigations prove that sludge contains Salmonellae in more than 90% of samples. The maximum number of organisms was 10 7 per litre. One of our most important findings was the fact that neither aerobic stabilization nor anaerobic digestion significantly reduces contamination with Salmonellae. Moreover we found that Salmonellae in sewage sludge spread on grass may survive up to 72 weeks. Fertilizing with unsanitized sludge may therefore lead to transmission from plant to animal. The increasing number of Salmonella carriers among our herds of cattle and their striking accumulation during the grazing period demonstrate that such transmission represents a growing danger. Sanitation of sludge to be used as fertilizer is therefore urgent. In our investigation of the sanitary effect of pasteurization (70degC for 30 min) and of gamma irradiation on sewage sludge, we examined the number of Enterobacteriaceae before and after irradiation in 259 specimens of sludge from 44 different sewage disposal plants. The doses applied were 100, 200, 300, 400 and also 500 krad. We found a linear reduction of Enterobacteriaceae with increasing doses; a dose of 300 krad resulted in a death rate of 10 4 - 10 8 , occasionally 10 9 Enterobacteriaceae; and there were less than 10 Enterobacteriaceae per gram in 97.2% of the samples irradiated with 300 krad. The results of these model experiments could be completely confirmed under practical conditions in the irradiation plant of Geiselbullach. The sanitary effect of gamma irradiation with 300-350 krad, determined by the reduction in Enterobacteriaceae, was equivalent to the effect of heat treatment by pasteurization. (author)

  8. Percutaneous catheter drainage of tuberculous psoas abscesses

    International Nuclear Information System (INIS)

    Pombo, F.; Martin-Egana, R.; Cela, A.; Diaz, J.L.; Linares-Mondejar, P.; Freire, M.

    1993-01-01

    Six patients with 7 tuberculous psoas or ilio-psoas abscesses were treated by CT-guided catheter drainage and chemotherapy. The abscesses (5 unilateral and 1 bilateral) were completely drained using a posterior or lateral approach. The abscess volume was 70 to 700 ml (mean 300 ml) and the duration of drainage 5 to 11 days (mean 7 days). Immediate local symptomatic improvement was achieved in all patients, and there were no procedural complications. CT follow-up at 3 to 9 months showed normalization in 5 patients, 2 of whom are still in medical therapy. One patient, who did not take the medication regularly, had a recurrent abscess requiring new catheter drainage after which the fluid collection disappeared. Percutaneous drainage represents an efficient and attractive alternative to surgical drainage as a supplement to medical therapy in the management of patients with large tuberculous psoas abscesses. (orig.)

  9. MATERIALS FOR THE FINAL COVER OF SANITARY LANDFILLS

    Directory of Open Access Journals (Sweden)

    Davorin Kovačić

    1994-12-01

    Full Text Available The paper deals with the selection of materials for the sea¬ling layer in the final cover of sanitary landfills. The sealing la¬yer is the most critical component of the final cover. Its role is to minimize percolation of water through the final cover. Ma¬terials used for the construction of the sealing layer are either of mineral origin (compacted clay or geosynthetic (geomem¬brane. They are most often used in combination creating com¬posite liners. Recently alternative materials are also used like paper mill sludge or discarded swelling clay.

  10. Definition of the drainage filter problem

    NARCIS (Netherlands)

    Zaslavsky, D.

    1977-01-01

    It is common to consider the following: I. Retention of soil particles that may enter the drainage pipe and cause its clogging. For some sensitive structures it is important to prevent settlements due to soil transportation by drainage water.

  11. Banana fertigation with treated sanitary wastewater: postharvest and microbiological quality

    Directory of Open Access Journals (Sweden)

    Pablo Fernando Santos Alves

    2017-06-01

    Full Text Available Sewage may serve as a source of water and nutrients for plants. In this study, the effects of fertigation with treated sanitary wastewater from Janaúba Sewage Treatment Plant were evaluated on the postharvest and microbiological quality of ‘Prata-Anã’ banana. A randomized block experimental design was used. Four concentrations of wastewater were tested (70, 130, 170, and 200% of 150 kg ha-1 sodium. A wastewater-free control treatment was used for comparison. Two crop cycles were assessed for postharvest and microbiological quality. The parameters measured included total soluble solids, titratable acidity, total soluble solids/titratable acidity ratio, pH, total coliforms, and fecal coliforms on both the peel and the pulp. In the first crop cycle, both soluble solids and fruit pulp pH decreased as wastewater level increased up to a maximum of 141.5%. These correlations were not observed in the second cycle. Wastewater management did not affect the titratable acidity of the soluble solids. The agricultural application of treated sanitary wastewater provided banana fruits with a microbiological profile similar to that obtained with the control (pure water and with mineral fertilizers. A microbial balance is necessary to maintain the nutritional status of the banana crop.

  12. Mineralogy and microstructure of hydrated phases during the pozzolanic reaction in the sanitary ware waste/Ca(OH)2 system

    OpenAIRE

    Medina, César; Sáez del Bosque, Isabel F.; Asensio, Eloy; Frías, Moisés; Sánchez de Rojas, M Isabel

    2016-01-01

    Despite technological improvements in its production process, the sanitary ware industry inevitably generates a certain volume of discards, products whose quality is not up to standard. The present paper is the first to scientifically explore claybased sanitary ware waste (SW) with a view to its valorization as an addition in the design of new, more environmentally friendly cements. The focus is on characterization of the waste and its pozzolanicity, as well as the struct...

  13. Subsurface drainage

    CSIR Research Space (South Africa)

    Van Der

    1993-09-01

    Full Text Available and long term behavior were evaluated. Laboratory tests for geotextile selection are recommended and tentative criteria given. The use of fin drains was evaluated in the laboratory and a field study to monitor the efficacy of drainage systems was started...

  14. The removal of ammonia from sanitary landfill leachate using a series of shallow waste stabilization ponds.

    Science.gov (United States)

    Leite, V D; Pearson, H W; de Sousa, J T; Lopes, W S; de Luna, M L D

    2011-01-01

    This study evaluated the efficiency of a shallow (0.5 m deep) waste stabilization pond series to remove high concentrations of ammonia from sanitary landfill leachate. The pond system was located at EXTRABES, Campina Grande, Paraiba, Northeast Brazil. The pond series was fed with sanitary landfill leachate transported by road tanker to the experimental site from the sanitary landfill of the City of Joao Pessoa, Paraiba. The ammoniacal-N surface loading on the first pond of the series was equivalent to 364 kg ha(-1) d(-1) and the COD surface loading equivalent to 3,690 kg ha(-1) d(-1). The maximum mean ammonia removal efficiency was 99.5% achieved by the third pond in the series which had an effluent concentration of 5.3 mg L(-1) ammoniacal-N for an accumulative HRT of 39.5 days. The removal process was mainly attributed to ammonia volatilization (stripping) from the pond surfaces as a result of high surface pH values and water temperatures of 22-26°C. Shallow pond systems would appear to be a promising technology for stripping ammonia from landfill leachate under tropical conditions.

  15. Hygienic assessment of habitat adverse social and sanitary factors in the Altai Krai

    Directory of Open Access Journals (Sweden)

    A.A. Ushakov

    2015-12-01

    Full Text Available The materials on health status, socio-economic, sanitary living conditions of the population of the Altai Krai have been analyzed. The comparative analysis of the conditions of life and health outcomes in urban and rural settlements’ population has been performed. The estimation of health indicators’ correlation has been carried out in children of age group 0-1 years, children of age group 0-14 years, teens of age group 15-17 years and adults of age group over 18 years, depending on the type (urban or rural of settlement with indicators of social and sanitary environmental factors. Regression equations for the health outcomes of different age groups on the level of hygiene and social environmental factors are set, regional critical (reference values are justified. The hygienic assessment of unfavorable social, health and sanitation of the environment on the health of the population in the Altai Krai is provided.

  16. The Use of Heat-Resistant Concrete Made with Ceramic Sanitary Ware Waste for a Thermal Energy Storage

    Directory of Open Access Journals (Sweden)

    Paweł Ogrodnik

    2017-12-01

    Full Text Available The paper presents the results obtained in the course of a study on the concrete made of aggregate obtained from wastes of sanitary ceramics. Previous examinations proved high in strength and durability of concrete of this type, and it showed a resistance to high temperatures. The material was classified as a fireproof concrete. While searching for the optimal applications of such concrete, a series of examinations and analyses on its thermal energy storage (TES properties were performed. This paper describes the two-stage experiment on the thermal behavior of the concrete made with sanitary ceramic wastes during cooling processes in comparison to different building materials subjected to the same thermal conditions. On the basis of the thermal, infrared analysis, and suitable calculations, the thermal power and the ability of the composite to store thermal energy was estimated. Finally, it was stated that the concrete made of sanitary ceramic waste aggregate and alumina cement can be recommended as a heat-accumulating material, and in combination with high durability can be used, e.g., for the construction of fireplace bodies.

  17. An Analysis of the Sanitary and Welfare Conditions of Tourism Centers in Lorestan Province: A Qualitative Study

    Directory of Open Access Journals (Sweden)

    Koroush Saki

    2018-03-01

    Full Text Available Background and Objectives: Due to the rapid growth of tourism industry, appropriate management and supervision of tourism centers by improving the sanitary, welfare and security situation of these centers is essential. Accordingly, this study aimed to investigate sanitary and welfare status of tourism centers in Lorestan province. Material and Methods: This research is a qualitative study conducted through semi-structured Interview with tourists. Data analysis was done using content analysis. After collecting and analyzing data, findings were classified into themes and sub-themes. Results: The findings were categorized into 6 main themes and 24 sub-themes. The main themes were general sanitary conditions, welfare facilities, transportation, healthcare services, security, and management and supervision. Conclusion: According to the findings and participants’ points of view, tourists are not satisfied with health care status of tourist centers. Therefore, in order to minimize the health problems of tourism centers and maximize attracting tourists, short-term and long-term plans should be put on the agenda of tourism managers and stakeholders of the Lorestan province.

  18. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    Science.gov (United States)

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Role of Community in Swachh Bharat Mission. Their Knowledge, Attitude and Practices of Sanitary Latrine Usage in Rural Areas, Tamil Nadu.

    Science.gov (United States)

    Anuradha, R; Dutta, Ruma; Raja, J Dinesh; Lawrence, D; Timsi, J; Sivaprakasam, P

    2017-01-01

    In most developing countries, open defecation is the 'way of life'. This practice is considered as the most serious health and environmental hazard. Prime Minister of India launched the "Swachh Bharat Mission" to accelerate the efforts for achieving universal sanitation coverage and to put focus on sanitation. To find the knowledge, attitude and practices of sanitary latrines usage in rural area, Tamil Nadu. This was a cross sectional study conducted among rural population in Kuthambakkam village, Tamil Nadu. There were a total of 1175 households in Kuthambakkam village. These households were serially numbered and of these a sample of 275 households were selected for the study using simple random sampling technique by lottery method. A structured questionnaire was used to collect information regarding the background characteristics, their knowledge, attitude and practices towards sanitary latrines usage. Descriptive statistics were calculated for background variables, the prevalence of sanitary latrines usage and open air defecation. Association between factors responsible for open air defecation was found by using chi square test. The prevalence of usage of household sanitary latrine and community latrines was 62.5% and 4.3% respectively. The prevalence of open air defecation among the study participants was 33.1%.Significant association was found between low standard of living and open air defecation practice. To solve the problem of underutilization of sanitary latrines, planning and conducting Information Education Communication activities is very essential. Effective political and administrative support is needed to scale up the sanitation program.

  20. Thoracoscopic Surgery for Pneumothorax Following Outpatient Drainage Therapy.

    Science.gov (United States)

    Sano, Atsushi; Yotsumoto, Takuma

    2017-10-20

    We investigated the outcomes of surgery for pneumothorax following outpatient drainage therapy. We reviewed the records of 34 patients who underwent operations following outpatient drainage therapy with the Thoracic Vent at our hospital between December 2012 and September 2016. Indications for outpatient drainage therapy were pneumothorax without circulatory or respiratory failure and pleural effusion. Indications for surgical treatment were persistent air leakage and patient preference for surgery to prevent or reduce the incidence of recurrent pneumothorax. Intraoperatively, 9 of 34 cases showed loose adhesions around the Thoracic Vent, all of which were dissected bluntly. The preoperative drainage duration ranged from 5 to 13 days in patients with adhesions and from 3 to 19 days in those without adhesions, indicating no significant difference. The duration of preoperative drainage did not affect the incidence of adhesions. The operative duration ranged from 30 to 96 minutes in patients with adhesions and from 31 to 139 minutes in those without adhesions, also indicating no significant difference. Outpatient drainage therapy with the Thoracic Vent was useful for spontaneous pneumothorax patients who underwent surgery, and drainage for less than 3 weeks did not affect intraoperative or postoperative outcomes.

  1. Foamed emulsion drainage: flow and trapping of drops

    OpenAIRE

    Schneider, Maxime; Zou, Ziqiang; Langevin, Dominique; Salonen, Anniina

    2017-01-01

    Foamed emulsions are ubiquitous in our daily life but the ageing of such systems is still poorly understood. In this study we investigate foam drainage and measure the evolution of the gas, liquid and oil volume fractions inside the foam. We evidence three regimes of ageing. During an initial period of fast drainage, both bubbles and drops are very mobile. As the foam stabilises drainage proceeds leading to a gradual decrease of the liquid fraction and slowing down of drainage. Clusters of oi...

  2. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): design and rationale of a randomized controlled trial

    OpenAIRE

    Wiggers, Jimme K; Coelen, Robert JS; Rauws, Erik AJ; van Delden, Otto M; van Eijck, Casper HJ; de Jonge, Jeroen; Porte, Robert J; Buis, Carlijn I; Dejong, Cornelis HC; Molenaar, I Quintus; Besselink, Marc GH; Busch, Olivier RC; Dijkgraaf, Marcel GW; van Gulik, Thomas M

    2015-01-01

    Background Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when severe drainage-related complications deteriorate the patients? condition or increase the risk of postoperative morbidity. Biliary drainage can cause cholangitis/cholecystitis, pancreatitis, hemorr...

  3. Percutaneous drainage treatment of primary liver abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Berger, H.; Pratschke, E.; Berr, F.; Fink, U.

    1989-02-01

    28 primary liver abscesses, including 9 amoebic abscesses, in 24 patients were drained percutaneously. Indication for drainage in amoebic abscesses was imminent rupture and clinical symptoms as pleural effusion, lung atelectasis and pain. 95% of the primary abscesses were cured by percutaneous drainage and systemic antibiotic treatment. There was one recurrence of abscess, which was managed surgically. Reasons for drainage failure were: tumour necrosis and tumour perforation with secondary liver abscess.

  4. Radiologic drainage of infected and noninfected thoracic fluid collections

    International Nuclear Information System (INIS)

    Van Sonnenberg, E.; Casola, G.; Stavas, J.; Neff, C.C.; Varney, R.A.; Wittich, G.R.; Dillard, J.; Christensen, R.A.; Friedman, P.J.

    1987-01-01

    Radiologically guided drainage of 100 thoracic fluid collections is described in this paper. Collections that underwent drainage include empyemas, lung abscesses, bronchopleural fistulas (BPFs), mediastinal abscesses, paracardial collections, bronchogenic cysts, sequestrations, lymphoceles, lymphangiomas, malignant effusions, and necrotic tumors. Catheters were placed for sclerotherapy in nine patients. Guidance modalities (in descending order of frequency) were CT, US, fluoroscopy, and MR. Inadequate thoracostomy tube drainage occurred in a third of the patients prior to radiologic drainage. Drainages were effective in 85% of cases, sparing surgery or another thoracostomy tube. Complications occurred in 7% of patients, most being minor and none requiring operation. Criteria for drainage of lung abscess and BPF will be emphasized, as will techniques and methods of follow-up

  5. Tile Drainage Expansion Detection using Satellite Soil Moisture Dynamics

    Science.gov (United States)

    Jacobs, J. M.; Cho, E.; Jia, X.

    2017-12-01

    In the past two decades, tile drainage installation has accelerated throughout the Red River of the North Basin (RRB) in parts of western Minnesota, eastern North Dakota, and a small area of northeastern South Dakota, because the flat topography and low-permeability soils in this region necessitated the removal of excess water to improve crop production. Interestingly, streamflow in the Red River has markedly increased and six of 13 major floods during the past century have occurred since the late 1990s. It has been suggested that the increase in RRB flooding could be due to change in agricultural practices, including extensive tile drainage installation. Reliable information on existing and future tile drainage installation is greatly needed to capture the rapid extension of tile drainage systems and to locate tile drainage systems in the north central U.S. including the RRB region. However, there are few reliable data of tile drainage installation records, except tile drainage permit records in the Bois de Sioux watershed (a sub-basin in southern part of the RRB where permits are required for tile drainage installation). This study presents a tile drainage expansion detection method based on a physical principle that the soil-drying rate may increase with increasing tile drainage for a given area. In order to capture the rate of change in soil drying rate with time over entire RRB (101,500 km2), two satellite-based microwave soil moisture records from the Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E) and AMSR2 were used during 2002 to 2016. In this study, a sub-watershed level (HUC10) potential tile drainage growth map was developed and the results show good agreement with tile drainage permit records of six sub-watersheds in the Bois de Sioux watershed. Future analyses will include improvement of the potential tile drainage map through additional information using optical- and thermal-based sensor products and evaluation of its

  6. Bundle of measures for external cerebral ventricular drainage-associated ventriculitis.

    Science.gov (United States)

    Chatzi, Maria; Karvouniaris, Marios; Makris, Demosthenes; Tsimitrea, Eleni; Gatos, Charalampos; Tasiou, Anastasia; Mantzarlis, Kostas; Fountas, Kostas N; Zakynthinos, Epaminondas

    2014-01-01

    To assess the prevalence and outcome of external cerebral ventricular drainage-associated ventriculitis in neurocritical patients before and after the implementation of a bundle of external cerebral ventricular drainage-associated ventriculitis control measures. Clinical prospective case series. University Hospital of Larissa, Greece. Consecutive patients were recruited from the ICU of the hospital. Patient inclusion criteria included presence of external ventricular drainage and ICU stay more than 48 hours. The bundle of external cerebral ventricular drainage-associated ventriculitis control measures included 1) reeducation of ICU personnel on issues of infection control related to external cerebral ventricular drainage, 2) meticulous intraventricular catheter handling, 3) cerebrospinal fluid sampling only when clinically necessary, and 4) routine replacement of the drainage catheter on the seventh drainage day if the catheter was still necessary. The bundle was applied after an initial period (preintervention) where standard policy for external cerebral ventricular drainage-associated ventriculitis was established. External cerebral ventricular drainage-associated ventriculitis prevalence, external cerebral ventricular drainage-associated ventriculitis events per 1,000 drainage days (drain-associated infection rate), length of ICU stay, Glasgow Outcome Scale at 6 months, and risk factors for external cerebral ventricular drainage-associated ventriculitis. Eighty-two patients entered the study in the preintervention period and 57 patients during the intervention period. During the preintervention and intervention period, external cerebral ventricular drainage-associated ventriculitis prevalence was 28% and 10.5% (p = 0.02) and drain-associated infection rate was 18 and 7.1, respectively (p = 0.0001); mean (95% CI) length of ICU stay in patients who presented external cerebral ventricular drainage-associated ventriculitis was 44.4 days (36.4-52.4 d), whereas mean

  7. Modes of supraglacial lake drainage and dynamic ice sheet response

    Science.gov (United States)

    Das, S. B.; Behn, M. D.; Joughin, I. R.

    2011-12-01

    We investigate modes of supraglacial lake drainage using geophysical, ground, and remote sensing observations over the western margin of the Greenland ice sheet. Lakes exhibit a characteristic life cycle defined by a pre-drainage, drainage, and post-drainage phase. In the pre-drainage phase winter snow fills pre-existing cracks and stream channels, efficiently blocking past drainage conduits. As temperatures increase in the spring, surface melting commences, initially saturating the snow pack and subsequently forming a surface network of streams that fills the lake basins. Basins continue to fill until lake drainage commences, which for individual lakes occurs at different times depending on the previous winter snow accumulation and summer temperatures. Three styles of drainage behavior have been observed: (1) no drainage, (2) slow drainage over the side into an adjacent pre-existing crack, and (3) rapid drainage through a new crack formed beneath the lake basin. Moreover, from year-to-year individual lakes exhibit different drainage behaviors. Lakes that drain slowly often utilize the same outflow channel for multiple years, creating dramatic canyons in the ice. Ultimately, these surface channels are advected out of the lake basin and a new channel forms. In the post-drainage phase, melt water continues to access the bed typically through a small conduit (e.g. moulin) formed near a local topographic minimum along the main drainage crack, draining the lake catchment throughout the remainder of the melt season. This melt water input to the bed leads to continued basal lubrication and enhanced ice flow compared to background velocities. Lakes that do not completely drain freeze over to form a surface ice layer that persists into the following year. Our results show that supraglacial lakes show a spectrum of drainage behaviors and that these styles of drainage lead to varying rates and timing of surface meltwater delivery to the bed resulting in different dynamic ice

  8. Final Disposal of Solid Waste in Sanitary Landfills and Human Health

    Directory of Open Access Journals (Sweden)

    Gustavo Silveira Graudenz

    2012-06-01

    Full Text Available This article presents a critical review of scientific literature on waste sanitary landfills and its effects on human health, with an approach to the adverse effects that are most commonly associated to living near waste landfills. The health variables included were low birth weight, congenital abnormalities, some types of neoplasms, allergies, asthma and other respiratory diseases using the MEDLINE, LILACS and CAPES’ thesis post graduation database for systematic review. In spite of the fact that some studies indicate positive asssociation between health risks and living close to landfills, the majority of the studies, mainly the most recent ones, do not demonstrate a significant health risk in this condition. Some common limitations and bias of the work in the field are discussed. The lack of direct quantification of exposure, lack of prospective approach and no comparaison of the different types and quality of management of the residues are common limitations to most studies. So far, there is weak evidence to support significant epidemiological health risks associated to landfills. More interdisciplinary research should improve the knoledge of the health risks related to living in the proximity to sanitary landfills.

  9. PHYSIOLOGICAL AND SANITARY QUALITY OF DESICCATED AND STORED AZUKI BEAN SEEDS

    Directory of Open Access Journals (Sweden)

    CÁSSIO JARDIM TAVARES

    2016-01-01

    Full Text Available The objective of this research was to evaluate the effects of using different herbicides as desiccants in pre - harvest and the effects of storage on the physiological and sanitary quality of azuki bean seeds ( Vigna angularis Willd. The experiment was arranged in a randomized complete block design in a split plot scheme, with four replications. Four herbicides were tested: paraquat (400 g a.i. ha - 1 , glufosinate ammonium (400 g a.i. ha - 1 , glyphosate (720 g a.i. ha - 1 , flumioxazin (30 g a.i. ha - 1 and a control without herbicide application. In the subplots seed quality was tested in two evaluation periods: at harvest and six months after harvest. Desiccant was applied when the azuki beans were physiologically mature. We assessed the physiological and sanitary quality of the seeds using a vigour and seed health test. The use of glyphosate resulted in a higher incidence of abnormal seedlings and reduced size and weight of the seedlings. With paraquat and flumioxazin the physiological quality was maintained and there was reduced pathogen infestation in the seeds six months after harvest. Storage affected the physiological quality of the azuki bean seeds.

  10. Percutaneous drainage treatment of primary liver abscesses

    International Nuclear Information System (INIS)

    Berger, H.; Pratschke, E.; Berr, F.; Fink, U.; Klinikum Grosshadern, Muenchen; Klinikum Grosshadern, Muenchen

    1989-01-01

    28 primary liver abscesses, including 9 amoebic abscesses, in 24 patients were drained percutaneously. Indication for drainage in amoebic abscesses was imminent rupture and clinical symptoms as pleural effusion, lung atelectasis and pain. 95% of the primary abscesses were cured by percutaneous drainage and systemic antibiotic treatment. There was one recurrence of abscess, which was managed surgically. Reasons for drainage failure were: tumour necrosis and tumour perforation with secondary liver abscess. (orig.) [de

  11. Endoscopic Ultrasound-Guided Biliary Drainage

    International Nuclear Information System (INIS)

    Artifon, Everson L.A.; Ferreira, Fla'vio C.; Sakai, Paulo

    2012-01-01

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  12. Endoscopic Ultrasound-Guided Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Artifon, Everson L.A.; Ferreira, Fla& #x27; vio C.; Sakai, Paulo [University of Saeo Paulo, Saeo Paulo (Brazil)

    2012-02-15

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  13. Predictors of chest drainage complications in trauma patients

    Directory of Open Access Journals (Sweden)

    CECÍLIA ARAÚJO MENDES

    2018-04-01

    Full Text Available ABSTRACT Objective: to identify predictors of chest drainage complications in trauma patients attended at a University Hospital. Methods: we conducted a retrospective study of 68 patients submitted to thoracic drainage after trauma, in a one-year period. We analyzed gender, age, trauma mechanism, trauma indices, thoracic and associated lesions, environment in which the procedure was performed, drainage time, experience of the performer, complications and evolution. Results: the mean age of the patients was 35 years and the male gender was the most prevalent (89%. Blunt trauma was the most frequent, with 67% of cases, and of these, 50% were due to traffic accidents. The mean TRISS (Trauma and Injury Severity Score was 98, with a mortality rate of 1.4%. The most frequent thoracic and associated lesions were, respectively, rib fractures (51% and abdominal trauma (32%. The mean drainage time was 6.93 days, being higher in patients under mechanical ventilation (p=0.0163. The complication rate was 26.5%, mainly poor drain positioning (11.77%. Hospital drainage was performed in 89% of cases by doctors in the first year of specialization. Thoracic drainage performed in prehospital care presented nine times more chances of complications (p=0.0015. Conclusion: the predictors of post-trauma complications for chest drainage were a procedure performed in an adverse site and mechanical ventilation. The high rate of complications demonstrates the importance of protocols of care with the thoracic drainage.

  14. Natural attenuation of antimony in mine drainage water

    International Nuclear Information System (INIS)

    Manaka, Mitsuo; Yanase, Nobuyuki; Sato, Tsutomu; Fukushi, Keisuke

    2007-01-01

    In this study, we investigated the natural attenuation of antimony (Sb) in the drainage water of an abandoned mine. Drainage water, waste rocks, and ocherous precipitates collected from the mine were investigated in terms of their mineralogy and chemistry. The chemistry of the drainage water was analyzed by measuring pH, oxidation-reduction potential (ORP), and electric conductivity on site as well as by inductively coupled plasma mass spectrometry and ion chromatography. As the drainage flowed downstream, the pH decreased rapidly from 7.05 to 3.26 and then increased slowly to 3.50. In a section where the pH increased, ocherous precipitates occur on a drainage water channel. We determined Sb levels in the drainage water, and the distribution of Sb in the mineral phases of waste rocks and precipitates was estimated by means of a sequential extraction procedure. The results of these investigations indicated that Sb, which is generated by the dissolution of stibnite (Sb 2 S 3 ) and secondary formed Sb minerals in waste rocks, was attenuated by iron-bearing ocherous precipitates, especially schwertmannite, that form over time in the drainage water. The Sb concentrations in the ocherous precipitates were up to 370 mg/kg, whereas the Sb concentrations in the drainage water downstream were below background levels (0.6 μg/L). Bulk distribution coefficients (K d ) for this Sb adsorption to the precipitates ranges up to at least 10 5 L/kg. (author)

  15. adequacy of drainage channels f drainage channels in a small

    African Journals Online (AJOL)

    eobe

    The area upon which waterfalls and the netw through ... ls were determined using the rational model and manning's equation. A .... runoff, including roads, culverts and drainage systems. ... hence, detailed design information of the drain is.

  16. Experimental and numerical analysis of the drainage of aluminium foams

    International Nuclear Information System (INIS)

    Brunke, O; Hamann, A; Cox, S J; Odenbach, S

    2005-01-01

    Drainage is one of the driving forces for the temporal instability of molten metal foams. For usual aqueous foams this phenomenon is well examined and understood on both the experimental and the theoretical side. The situation is different for metallic foams. Due to their opaque nature, the observation of drainage is only possible by either measuring the density distribution of solidified samples ex situ or by x-ray or neutron radioscopy. Up to now there exists just one theoretical study describing the drainage behaviour of metallic foams incorporating the drainage equation, the temperature dependence of the viscosity and thermal transport. This paper will present results on the drainage behaviour of aluminium foams grown by a powder-metallurgical production route. For this purpose an experiment which allows the observation of drainage in cylindrical metal foam columns has been developed. Experimental density profiles after different drainage times are measured ex situ and compared to numerical results of the standard drainage equation for aqueous foams. This first comparison between the density redistribution of metallic aluminium foams and numerical solutions shows that the standard drainage equation can be used to explain the drainage behaviour of metallic foams

  17. Geochemical characterisation of seepage and drainage water quality from two sulphide mine tailings impoundments: Acid mine drainage versus neutral mine drainage

    Science.gov (United States)

    Heikkinen, P.M.; Raisanen, M.L.; Johnson, R.H.

    2009-01-01

    Seepage water and drainage water geochemistry (pH, EC, O2, redox, alkalinity, dissolved cations and trace metals, major anions, total element concentrations) were studied at two active sulphide mine tailings impoundments in Finland (the Hitura Ni mine and Luikonlahti Cu mine/talc processing plant). The data were used to assess the factors influencing tailings seepage quality and to identify constraints for water treatment. Changes in seepage water quality after equilibration with atmospheric conditions were evaluated based on geochemical modelling. At Luikonlahti, annual and seasonal changes were also studied. Seepage quality was largely influenced by the tailings mineralogy, and the serpentine-rich, low sulphide Hitura tailings produced neutral mine drainage with high Ni. In contrast, drainage from the high sulphide, multi-metal tailings of Luikonlahti represented typical acid mine drainage with elevated contents of Zn, Ni, Cu, and Co. Other factors affecting the seepage quality included weathering of the tailings along the seepage flow path, process water input, local hydrological settings, and structural changes in the tailings impoundment. Geochemical modelling showed that pH increased and some heavy metals were adsorbed to Fe precipitates after net alkaline waters equilibrated with the atmosphere. In the net acidic waters, pH decreased and no adsorption occurred. A combination of aerobic and anaerobic treatments is proposed for Hitura seepages to decrease the sulphate and metal loading. For Luikonlahti, prolonged monitoring of the seepage quality is suggested instead of treatment, since the water quality is still adjusting to recent modifications to the tailings impoundment.

  18. 30 CFR 71.500 - Sanitary toilet facilities at surface work sites; installation requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Sanitary toilet facilities at surface work sites; installation requirements. 71.500 Section 71.500 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND...

  19. Contribution of computed tomography on chest drainage guidance

    International Nuclear Information System (INIS)

    Douvlou, E.; Tzortzis, D.; Vlachou, I.; Petrocheilou, G.; Safarika, V.; Fragopoulou, L.; Stathopoulou, S.; Kokkinis, C.

    2012-01-01

    Full text: Introduction: Thoracic collections (encysted pleural, endopulmonary, mediastinal) are common findings in major trauma hospitals mainly in need of further treatment as drainage. Objectives and tasks: To evaluate the CT-guidance, as a method of choice for thoracic drainages. Material and methods: 35 CT-guided chest drainages were performed for diagnostic and therapeutic purpose in 33 patients, with a mean age of 62 years. Of the 35 drainages, 31 were encysted at the pleura, 3 of them were endopulmonary and 1 was in the mediastinum. During the procedure we used needles of 15cm long and 18-22 G diameter for small collections while for 'large' collections drainage catheters of 10-16 F were placed. Results: All the CT-guided drainages of the chest were successful. Of them, 7 were pleural effusion collections while 24 were exudate collections (18 inflammatory and 6 neoplastic) and all were developed in the lungs or the mediastinum. In all the cases that a catheter was placed, full removal of the collections was achieved leading to a remarkable improvement of the patient's condition. Non-significant pneumothorax and tiny endopulmonary bleeding were the complications that occurred. Conclusion: CT-guided drainage of thoracic collections is an accurate and secure procedure and achieves high diagnostic and therapeutic results

  20. Evaluation of new location of Isfahan′s sanitary landfill site with Oleckno method

    Directory of Open Access Journals (Sweden)

    Maryam Salimi

    2013-01-01

    Full Text Available Aims: The objective of present study was to evaluate the new location of Isfahan solid waste sanitary landfill using Geographical Information System (GIS based on the Oleckno index method (OIM. Materials and Methods: This study was on the field- and library-based data collection and surveys of relevant data. Assessment parameters included average annual rainfall, soil type and ground water beneath and adjucent to the landfill site. To analyze data, ArcGIS version 9.3 was used. Results: In 2010 the total rainfall in the landfill location was less than 150 mm/year. The soil type was clay loam, and the average distance from the floor of the landfill to the groundwater level was 3-9 meters. As calculated results showed that, the Oleckno index (OI score in the study area was 40. Conclusion: The new Isfahan′s sanitary solid waste landfill site had a good OI and the possibility of contamination of groundwater by leachate production based on this method also was low.

  1. [Endoscopic ultrasound guided rendezvous for biliary drainage].

    Science.gov (United States)

    Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal

    2015-04-27

    Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.

  2. Methodology for Identifying and Quantifying Metal Pollutant Sources in Storm Water Runoff

    Science.gov (United States)

    2015-02-01

    sanitary sewer are not viable options. In addition, visual inspections of the drainage areas have been insufficient in identifying and quantifying the...diverting the runoff into the sanitary sewer system, but the cost could exceed millions of dollars. Instead of capturing and treating all stormwater...Unknown Appears only if Building Siding is “metal” Roof Material roof_mat_d Built Up, Metal Panel, Asphalt, Fabric, Clay , Slate, Wood, Other

  3. Role of community in swachh bharat mission. their knowledge, attitude and practices of sanitary latrine usage in rural areas, Tamil Nadu

    Directory of Open Access Journals (Sweden)

    R Anuradha

    2017-01-01

    Full Text Available Background: In most developing countries, open defecation is the 'way of life'. This practice is considered as the most serious health and environmental hazard. Prime Minister of India launched the “Swachh Bharat Mission” to accelerate the efforts for achieving universal sanitation coverage and to put focus on sanitation. Objective: To find the knowledge, attitude and practices of sanitary latrines usage in rural area, Tamil Nadu. Materials and Methods: This was a cross sectional study conducted among rural population in Kuthambakkam village, Tamil Nadu. There were a total of 1175 households in Kuthambakkam village. These households were serially numbered and of these a sample of 275 households were selected for the study using simple random sampling technique by lottery method. A structured questionnaire was used to collect information regarding the background characteristics, their knowledge, attitude and practices towards sanitary latrines usage. Descriptive statistics were calculated for background variables, the prevalence of sanitary latrines usage and open air defecation. Association between factors responsible for open air defecation was found by using chi square test. Results: The prevalence of usage of household sanitary latrine and community latrines was 62.5% and 4.3% respectively. The prevalence of open air defecation among the study participants was 33.1%.Significant association was found between low standard of living and open air defecation practice. Conclusions: To solve the problem of underutilization of sanitary latrines, planning and conducting Information Education Communication activities is very essential. Effective political and administrative support is needed to scale up the sanitation program.

  4. Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Xiaojun; Jin Wenhui; Dai Dingke; Yu Ping; Gao Kun; Zhai Renyou

    2007-01-01

    Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 cases installed stent and plastic catheter together. Sixty-four cases received plastic catheters in this series, 35 cases installed two or more catheters for bilateral drainage, 28 cases installed external and internal drainage catheters, 12 eases installed external drainage catheters, and 24 eases installed both of them. There were 17 patients involving incorporative infection before procedure, 13 cases cured after procedure, and 15 new patients got inflammation after procedure. 13 cases showed increase of amylase (from May, 2004), 8 eases had bloody bile drainage and 1 case with pyloric obstruction. Total serum bilirubin reduced from (386 ± 162) μmol/L to (161 ± 117) μmol/L, (P<0.01) short term curative effect was related with the type of hilar cholangiocarcinoma. The survival time was 186 days(median), and 1, 3, 6, 12 month survival rate were 89.9%, 75.3%, 59.6%, 16.9%, respectively. Conclusion: Percutaneous transhepatic bile drainage is a safe and effective palliative therapy of malignant

  5. A review of the Y-12 Plant discharge of enriched uranium to the sanitary sewer (DEUSS)

    International Nuclear Information System (INIS)

    1991-09-01

    The Oak Ridge Y-12 Plant is situated adjacent to the Oak Ridge city limits and is operated by the United States Department of Energy (DOE). The Y-12 Plant is located on 4,860 acres, which is collectively referred to as the Y-12 Plant site. Among the missions for which the facility is in existence are producing nuclear weapons components, supporting weapon design laboratories, and processing special nuclear materials (SNM). The Y-12 Plant is under the regulatory guidance of DOE Order 5400.5 and has complied with the technical requirements governing SNM since its issue. However, an in-depth review with appropriate documentation had not been performed, prior to the effect presented herein, to substantiate this claim. As a result of the solid waste issue, it was determined that other types of waste should be formally reviewed for content with respect to SNM. Therefore, a project was formed to investigate the conveyance of SNM through the sanitary sewer system. It is emphasized that this project addresses only effluent from the sanitary sewer system and not the storm sewer system. The project reviewed sanitary sewer data both for the Y-12 Plant and the Y-12 Plant site

  6. A review of the Y-12 Plant discharge of enriched uranium to the sanitary sewer (DEUSS)

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    The Oak Ridge Y-12 Plant is situated adjacent to the Oak Ridge city limits and is operated by the United States Department of Energy (DOE). The Y-12 Plant is located on 4,860 acres, which is collectively referred to as the Y-12 Plant site. Among the missions for which the facility is in existence are producing nuclear weapons components, supporting weapon design laboratories, and processing special nuclear materials (SNM). The Y-12 Plant is under the regulatory guidance of DOE Order 5400.5 and has complied with the technical requirements governing SNM since its issue. However, an in-depth review with appropriate documentation had not been performed, prior to the effect presented herein, to substantiate this claim. As a result of the solid waste issue, it was determined that other types of waste should be formally reviewed for content with respect to SNM. Therefore, a project was formed to investigate the conveyance of SNM through the sanitary sewer system. It is emphasized that this project addresses only effluent from the sanitary sewer system and not the storm sewer system. The project reviewed sanitary sewer data both for the Y-12 Plant and the Y-12 Plant site.

  7. Foamed emulsion drainage: flow and trapping of drops.

    Science.gov (United States)

    Schneider, Maxime; Zou, Ziqiang; Langevin, Dominique; Salonen, Anniina

    2017-06-07

    Foamed emulsions are ubiquitous in our daily life but the ageing of such systems is still poorly understood. In this study we investigate foam drainage and measure the evolution of the gas, liquid and oil volume fractions inside the foam. We evidence three regimes of ageing. During an initial period of fast drainage, both bubbles and drops are very mobile. As the foam stabilises drainage proceeds leading to a gradual decrease of the liquid fraction and slowing down of drainage. Clusters of oil drops are less sheared, their dynamic viscosity increases and drainage slows down even further, until the drops become blocked. At this point the oil fraction starts to increase in the continuous phase. The foam ageing leads to an increase of the capillary pressure until the oil acts as an antifoaming agent and the foam collapses.

  8. Priority Scale of Drainage Rehabilitation of Cilacap City

    Science.gov (United States)

    Rudiono, Jatmiko

    2018-03-01

    Characteristics of physical condition of Cilacap City is relatively flat and low to sea level (approximately 6 m above sea level). In the event of a relatively heavy rainfall resulting in inundation at several locations. The problem of inundation is a serious problem if there is in a dense residential area or occurs in publicly-used infrastructure, such as roads and settlements. These problems require improved management of which include how to plan a sustainable urban drainage system and environmentally friendly. The development of Cilacap City is increasing rapidly, this causes drainage system based on the Drainage Masterplan Cilacap made in 2006 has not been able to accommodate rain water, so, it is necessary to evaluate the drainage masterplan for subsequent rehabilitation. Priority scale rehabilitation of the drainage sections as a guideline is an urgent need of rehabilitation in the next time period.

  9. An update on the drainage of pyogenic lung abscesses

    Directory of Open Access Journals (Sweden)

    Siraj O Wali

    2012-01-01

    Full Text Available Most lung abscesses (80-90% are now successfully treated with antibiotics; however, this conservative approach may occasionally fail. When medical treatment fails, pulmonary resection is usually advised. Alternatively, percutaneous transthoracic tube drainage or endoscopic drainage can be considered, though both remain controversial. In this communication, the medical literature focusing on percutaneous tube drainage efficacy, indications, techniques, complications, and mortality, as well as available data regarding endoscopic drainage are reviewed.

  10. An Optimal Balance between Efficiency and Safety of Urban Drainage Networks

    Science.gov (United States)

    Seo, Y.

    2014-12-01

    Urban drainage networks have been developed to promote the efficiency of a system in terms of drainage time so far. Typically, a drainage system is designed to drain water from developed areas promptly as much as possible during floods. In this regard, an artificial drainage system have been considered to be more efficient compared to river networks in nature. This study examined artificial drainage networks and the results indicate they can be less efficient in terms of network configuration compared with river networks, which is counter-intuitive. The case study of 20 catchments in Seoul, South Korea shows that they have wide range of efficiency in terms of network configuration and consequently, drainage time. This study also demonstrates that efficient drainage networks are more sensitive to spatial and temporal rainfall variation such as rainstorm movement. Peak flows increase more than two times greater in effective drainage networks compared with inefficient and highly sinuous drainage networks. Combining these results, this study implies that the layout of a drainage network is an important factor in terms of efficient drainage and also safety in urban catchments. Design of an optimal layout of the drainage network can be an alternative non-structural measures that mitigate potential risks and it is crucial for the sustainability of urban environments.

  11. Nonsurgical drainage of splenic abscess

    International Nuclear Information System (INIS)

    Berkman, W.A.; Harris, S.A. Jr.; Bernardino, M.E.

    1983-01-01

    The mortality associated with intraabdominal abscess remains high despite modern surgical methods and antibiotics. Draingae of abscesses of the abdomen, retroperitoneum, pelvis, pancreatic pseudocyst, mediastinum, and lung may be treated effectively by percutaneous catheter placement. In several reports of percutaneous abdominal abscess drainage, only three cases of splenic abscess drainage have been reported. The authors have recently drained two splenic abscesses with the aid of computed tomography (CT) and emphasize several advantages of the percutaneous guided approach

  12. Innovative in situ treatment approach for DOE Savannah River Site Sanitary Landfill

    International Nuclear Information System (INIS)

    Knapp, J.; Suer, A.

    1994-01-01

    Pursuant to a settlement agreement reached between the US Department of Energy (DOE) and the South Carolina Department of Health and Environmental Control (SCDHEC), the Sanitary Landfill at the Savannah River Site will be closed. This paper addresses the approach used to select the innovative in situ treatment alternative for the groundwater and the vadose zone associated with the landfill

  13. Analysis of glycerin waste in A-Area sanitary treatment facility material

    International Nuclear Information System (INIS)

    1995-01-01

    TNX has a large supply of 55 gallon drums containing pure glycerin and glycerin with additives. The glycerin drums were procured to simulate the glass stream in a pilot-scale melter process at TNX. Since the glycerin was not used for this process, TNX is looking at disposing the material in a sanitary waste treatment facility onsite. The effect of adding the contents of the drums to sewage bacteria was tested. A drum of pure glycerin and a drum of glycerin mixed with lithium chloride were tested. The test consisted of mixing sanitary sludge material with the glycerin material. The purpose of the test was to determine if the glycerin impacted the aerobic bacterial population. The bacterial densities were determined by taking samples from the sludge/glycerin mixtures and using aerobic plate count methods. The total organic carbon (TOC) levels were measured before and after testing. The results indicate that the cell density of the aerobic bacteria increased with the addition of glycerin and the glycerin mixture and the TOC removal rate was different for all tests. Disposal of glycerin in the wastewater treatment facilities should pose no problems. Additional testing and analysis of the mixed samples should be done before its disposal in a waste water treatment facility

  14. Effect of viscosity on tear drainage and ocular residence time.

    Science.gov (United States)

    Zhu, Heng; Chauhan, Anuj

    2008-08-01

    An increase in residence time of dry eye medications including artificial tears will likely enhance therapeutic benefits. The drainage rates and the residence time of eye drops depend on the viscosity of the instilled fluids. However, a quantitative understanding of the dependence of drainage rates and the residence time on viscosity is lacking. The current study aims to develop a mathematical model for the drainage of Newtonian fluids and also for power-law non-Newtonian fluids of different viscosities. This study is an extension of our previous study on the mathematical model of tear drainage. The tear drainage model is modified to describe the drainage of Newtonian fluids with viscosities higher than the tear viscosity and power-law non-Newtonian fluids with rheological parameters obtained from fitting experimental data in literature. The drainage rate through canaliculi was derived from the modified drainage model and was incorporated into a tear mass balance to calculate the transients of total solute quantity in ocular fluids and the bioavailability of instilled drugs. For Newtonian fluids, increasing the viscosity does not affect the drainage rate unless the viscosity exceeds a critical value of about 4.4 cp. The viscosity has a maximum impact on drainage rate around a value of about 100 cp. The trends are similar for shear thinning power law fluids. The transients of total solute quantity, and the residence time agrees at least qualitatively with experimental studies. A mathematical model has been developed for the drainage of Newtonian fluids and power-law fluids through canaliculi. The model can quantitatively explain different experimental observations on the effect of viscosity on the residence of instilled fluids on the ocular surface. The current study is helpful for understanding the mechanism of fluid drainage from the ocular surface and for improving the design of dry eye treatments.

  15. Preoperative biliary drainage in hilar cholangiocarcinoma: When and how?

    Science.gov (United States)

    Paik, Woo Hyun; Loganathan, Nerenthran; Hwang, Jin-Hyeok

    2014-01-01

    Hilar cholangiocarcinoma is a tumor of the extrahepatic bile duct involving the left main hepatic duct, the right main hepatic duct, or their confluence. Biliary drainage in hilar cholangiocarcinoma is sometimes clinically challenging because of complexities associated with the level of biliary obstruction. This may result in some adverse events, especially acute cholangitis. Hence the decision on the indication and methods of biliary drainage in patients with hilar cholangiocarcinoma should be carefully evaluated. This review focuses on the optimal method and duration of preoperative biliary drainage (PBD) in resectable hilar cholangiocarcinoma. Under certain special indications such as right lobectomy for Bismuth type IIIA or IV hilar cholangiocarcinoma, or preoperative portal vein embolization with chemoradiation therapy, PBD should be strongly recommended. Generally, selective biliary drainage is enough before surgery, however, in the cases of development of cholangitis after unilateral drainage or slow resolving hyperbilirubinemia, total biliary drainage may be considered. Although the optimal preoperative bilirubin level is still a matter of debate, the shortest possible duration of PBD is recommended. Endoscopic nasobiliary drainage seems to be the most appropriate method of PBD in terms of minimizing the risks of tract seeding and inflammatory reactions. PMID:24634710

  16. Biogas recuperation in sanitary landfills; Recuperacao de biogas em aterros sanitarios

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Luiz Mario Queiroz [Companhia Paulista de Forca e Luz (CPFL), Campinas, SP (Brazil)

    1988-12-31

    This work shoes a retrospective about recovering biogas activity in sanitary landfill, where in the genesis of methane is emphasized. Also, a conceptual review was made and discussed focusing the technological aspects of the landfill methods. Further, two important aspects of the genesis of methane were discussed: the enhancement mechanisms for acceleration of the formation of methane and the production of biological input from leachate in landfill. (author) 36 refs., 3 figs.

  17. Drainage of Splenic Abscess: A Case Report | Kombo | Nigerian ...

    African Journals Online (AJOL)

    ... and was managed by tube drainage. His post operative recovery was uneventful. Conclusion: Tube drainage of the splenic abscess is encouraged if there is easy access to the abscess and there is evidence of residual splenic tissue in the critically ill patient. Key Word: Tube drainage, splenic abscess, splenectomy.

  18. The construction technology of Chinese ancient city drainage facilities

    Science.gov (United States)

    Hequn, Li; Yufengyun

    2018-03-01

    In ancient china, according to the local natural environment, a variety of drainage facilities were built in order to excrete rainwater, domestic sewage, production wastewater and so on. These drainage facilities were mainly made of pottery, bricks, wood, stone, etc. For example, ceramic water pipelines, buried in the ground, connect together one by one, and there was a slight drop from one end to the other in favor of drainage. These measures can also be used for reference in today’s urban drainage and flood control.

  19. Drainage divides, Massachusetts; Blackstone and Thames River basins

    Science.gov (United States)

    Krejmas, Bruce E.; Wandle, S. William

    1982-01-01

    Drainage boundaries for selected subbasins of the Blackstone and Thames River basins in eastern Hampden, eastern Hampshire, western Norfolk, southern Middlesex, and southern Worcester Counties, Massachusetts, are delineated on 12 topographic quadrangle maps at a scale of 1:24,000. Drainage basins are shown for all U.S. Geological Survey data-collection sites and for mouths of major rivers. Drainage basins are shown for the outlets of lakes or ponds and for streams where the drainage area is greater than 3 square miles. Successive sites along watercourses are indicated where the intervening area is at least 6 miles on tributary streams or 15 square miles along the Blackstone River, French River, or Quinebaug River. (USGS)

  20. An effective and comprehensive model for optimal rehabilitation of separate sanitary sewer systems.

    Science.gov (United States)

    Diogo, António Freire; Barros, Luís Tiago; Santos, Joana; Temido, Jorge Santos

    2018-01-15

    In the field of rehabilitation of separate sanitary sewer systems, a large number of technical, environmental, and economic aspects are often relevant in the decision-making process, which may be modelled as a multi-objective optimization problem. Examples are those related with the operation and assessment of networks, optimization of structural, hydraulic, sanitary, and environmental performance, rehabilitation programmes, and execution works. In particular, the cost of investment, operation and maintenance needed to reduce or eliminate Infiltration from the underground water table and Inflows of storm water surface runoff (I/I) using rehabilitation techniques or related methods can be significantly lower than the cost of transporting and treating these flows throughout the lifespan of the systems or period studied. This paper presents a comprehensive I/I cost-benefit approach for rehabilitation that explicitly considers all elements of the systems and shows how the approximation is incorporated as an objective function in a general evolutionary multi-objective optimization model. It takes into account network performance and wastewater treatment costs, average values of several input variables, and rates that can reflect the adoption of different predictable or limiting scenarios. The approach can be used as a practical and fast tool to support decision-making in sewer network rehabilitation in any phase of a project. The fundamental aspects, modelling, implementation details and preliminary results of a two-objective optimization rehabilitation model using a genetic algorithm, with a second objective function related to the structural condition of the network and the service failure risk, are presented. The basic approach is applied to three real world cases studies of sanitary sewerage systems in Coimbra and the results show the simplicity, suitability, effectiveness, and usefulness of the approximation implemented and of the objective function proposed

  1. Application of BIM Technology in Building Water Supply and Drainage Design

    Science.gov (United States)

    Wei, Tianyun; Chen, Guiqing; Wang, Junde

    2017-12-01

    Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.

  2. Percutaneous transhepatic biliary drainage: analysis of 175 cases

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kyung Jin; Lee, Sang Kwon; Kim, Tae Hun; Kim, Yong Joo; Kang, Duk Sik [College of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    1990-10-15

    Percutaneous transhepatic biliary drainage is a safe, effective and palliative means of treatment in biliary obstruction, especially in cases with malignant obstruction which are inoperable. 175 cases of transhepatic biliary drainage were performed on 119 patients with biliary obstruction from January 1985 to June 1989 at Kyung-pook National University Hospital. The causes of obstructive jaundice were 110 malignant diseases and 9 benign diseases. The most common indication for drainage was palliative intervention of obstruction secondary to malignant tumor in 89 cases. 86 cases of external drainage were performed including 3 cases of left duct approach, 29 cases of external-internal drainage and 60 cases of endoprosthesis. In external and external-internal drainages, immediate major complications (11.9%) occurred, including not restricted to, but sepsis, bile peritonitis and hemobilia. Delayed major complications (42.9%) were mainly catheter related. The delayed major complication of endoprosthesis resulted from obstruction of the internal stent. The mean time period to reobstruction of the internal stent was about 12 weeks. To improve management status, regular follow-up is required, as is education of both patients and their families as to when immediate clinical attention is mandated. Close communication amongst the varying medical specialities involved will be necessary to provide optional treatment for each patient.

  3. Percutaneous transhepatic biliary drainage: analysis of 175 cases

    International Nuclear Information System (INIS)

    Suh, Kyung Jin; Lee, Sang Kwon; Kim, Tae Hun; Kim, Yong Joo; Kang, Duk Sik

    1990-01-01

    Percutaneous transhepatic biliary drainage is a safe, effective and palliative means of treatment in biliary obstruction, especially in cases with malignant obstruction which are inoperable. 175 cases of transhepatic biliary drainage were performed on 119 patients with biliary obstruction from January 1985 to June 1989 at Kyung-pook National University Hospital. The causes of obstructive jaundice were 110 malignant diseases and 9 benign diseases. The most common indication for drainage was palliative intervention of obstruction secondary to malignant tumor in 89 cases. 86 cases of external drainage were performed including 3 cases of left duct approach, 29 cases of external-internal drainage and 60 cases of endoprosthesis. In external and external-internal drainages, immediate major complications (11.9%) occurred, including not restricted to, but sepsis, bile peritonitis and hemobilia. Delayed major complications (42.9%) were mainly catheter related. The delayed major complication of endoprosthesis resulted from obstruction of the internal stent. The mean time period to reobstruction of the internal stent was about 12 weeks. To improve management status, regular follow-up is required, as is education of both patients and their families as to when immediate clinical attention is mandated. Close communication amongst the varying medical specialities involved will be necessary to provide optional treatment for each patient

  4. Environmental and Geologic Assessment to Locate a Manual Sanitary Refill in the Mene de Mauroa Church, Venezuela

    Directory of Open Access Journals (Sweden)

    Simón E. Morales-Soto

    2016-05-01

    Full Text Available The inadequate disposal of urban wastes is nowadays an environmental issue having a negative impact on several communities. The objective of this investigation is to select the most adequate place to locate a manual sanitary landfill to dump the solid wastes from the Mene de Mauroa (Venezuela church. A total of 19 variables were subjected to a series of evaluations applying the scale and weight method. This method consists of comparing the variables according to their level of priority. The area with the highest score is to be selected as the most adequate area for the sanitary landfill according to a weighting scale of 5 values for the scoring of each variable.

  5. Veterinary-sanitary supervision of food from radiation-hygienic aspect in border crossing

    International Nuclear Information System (INIS)

    Vukovic, D.; Mitrovic, R.; Vicentijevic, M.; Kljajic, R.

    1997-01-01

    In this paper we presented the result of radiation control for imported food under the veterinary-sanitary supervision with radiation-hygienic aspect. The activity level of 137 Cs was from background to 18,8 Bq/kg and determined by gamma spectrometry. We discussed about results because 137 Cs relevance for radiation-hygienic certification and some samples of food was not satisfied maximum permitted levels. (author)

  6. Superficial drainage studies in open-pit mines

    International Nuclear Information System (INIS)

    Teixeira Junior, P.B.; Leite, C.B.B.

    1984-01-01

    Drainage studies concerning large open-pit mining projects can be of vital importance throughout the mining activity itself as they may assist in avoiding activity interruptions due to drainage problems, therefore representing substantial savings. These studies should, in fact, be carried out from the initial activity stages and shall be considered in operational, project and planning decisions in order to optimize results and reduce costs. This specific study presents a drainage study systematization proposal, enphasazing economic decision criteria. The authors comment on studies of this nature developed at the Caldas uranium mine - NUCLEBRAS. (D.J.M.) [pt

  7. Gravity Drainage Kinetics of Papermaking Fibrous Suspensions

    Directory of Open Access Journals (Sweden)

    Przybysz Piotr

    2014-12-01

    Full Text Available The study analyses application possibilities of filtration and thickening models in evaluation of papermaking suspension drainage rate. The authors proposed their own method to estimate the drainage rate on the basis of an existing Ergun capillary model of liquid flow through a granular material. The proposed model was less sensitive to porosity changes than the Ergun model. An empirical verification proved robustness of the proposed approach. Taking into account discrepancies in the published data concerning how the drainage velocity of papermaking suspension is defined, this study examines which of the commonly applied models matches experimental results the best.

  8. Surgical vs ultrasound-guided drainage of deep neck space abscesses: a randomized controlled trial: surgical vs ultrasound drainage.

    Science.gov (United States)

    Biron, Vincent L; Kurien, George; Dziegielewski, Peter; Barber, Brittany; Seikaly, Hadi

    2013-02-26

    Deep neck space abscesses (DNAs) are relatively common otolaryngology-head and neck surgery emergencies and can result in significant morbidity with potential mortality. Traditionally, surgical incision and drainage (I&D) with antibiotics has been the mainstay of treatment. Some reports have suggested that ultrasound-guided drainage (USD) is a less invasive and effective alternative in select cases. To compare I&D vs USD of well-defined DNAs, using a randomized controlled clinical trial design. The primary outcome measure was effectiveness (length of hospital stay (LOHS) and safety), and the secondary outcome measure was overall cost to the healthcare system. Patients presenting to the University of Alberta Emergency Department with a well-defined deep neck space abscess were recruited in the study. Patients were randomized to surgical or US-guided drainage, placed on intravenous antibiotics and admitted with airway precautions. Following drainage with either intervention, abscess collections were cultured and drains were left in place until discharge. Seventeen patients were recruited in the study. We found a significant difference in mean LOHS between patients who underwent USD (3.1 days) vs I&D (5.2 days). We identified significant cost savings associated with USD with a 41% cost reduction in comparison to I&D. USD drainage of deep neck space abscesses in a certain patient population is effective, safe, and results in a significant cost savings to the healthcare system.

  9. Improved drainage with active chest tube clearance.

    Science.gov (United States)

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  11. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  12. [Development of sanitary microbiology researches at the A. N. Marzeyev Institute for Hygiene and Medical Ecology, Academy of Medical Sciences of Ukraine (Kiev)].

    Science.gov (United States)

    Serdiuk, A M; Surmasheva, E V; Korchak, G I

    2011-01-01

    The paper describes the main stages of development of sanitary bacteriological studies at the leading hygiene research institute of Ukraine--the A. N Marzeyev Institute for Hygiene and Medical Ecology. These researches have made a substantial contribution to the formation and development of hygiene science in the former Soviet Union. The current and promising areas in sanitary microbiology in Ukraine are considered.

  13. Comments on Environmental and Sanitary Aspects of the Scorpionism by Tityus trivittatus in Buenos Aires City, Argentina

    Directory of Open Access Journals (Sweden)

    Adolfo Rafael de Roodt

    2014-04-01

    Full Text Available Deaths by venomous animals are medical emergencies that can lead to death and thus constitute sanitary problems in some regions of the world. In the South of America, the accidents by these animals are a common sanitary problem especially in warm, tropical or subtropical regions, related with rural work in several countries. Argentina is located in the extreme South of South America and a minor part of the continental surface is in tropical or subtropical regions, where most of the accidents by venomous animals happen. However, in the big cities in the center and South of the country, with no relation to rural work, scorpionism, mostly due to the synanthropic and facultative parthenogenetic scorpion Tityus trivittatus, has become a sanitary problem in the last few decades. This scorpion is present in the biggest cities of Argentina and in the last decades has killed over 20 children in provinces of the center and north of the country, mostly in big cities. In addition, it seems that this species is growing and spreading in new regions of the cities. In this revision, some characteristics of this scorpion regarding its habitat, spreading in Buenos Aires city, combat measures and available treatments are discussed.

  14. Evaluation of the sustainability of road drainage systems

    Science.gov (United States)

    García-Diez, Iván; Palencia, Covadonga; Fernández Raga, María

    2017-04-01

    Water is the most erosive agent that exists on the linear structures, because they are constantly subjected to outdoor condition like irregular infiltration, frosts and different rain intensities. Another variables that highly influence in the entire lifetime of a natural drainage system are the spatial and temporal variability of the rainfall, the soil, the vegetation cover and the design. All this factors are affecting the vulnerability of the clearings and embankments, by wearing away the weakest materials which surround the roads or train rails, producing erosion and very bumpy surfaces. The result is that the original pattern, developped to disminished the lost of soil, is not properly working and it cannot eliminate water, with the consequence destruction of the linear structure after several rainfall periods, and the accumulation of material down slope. The propose of this research focuses on analysing the drainage systems used in spanish roads and railways lines. For this purpose, a revision of the literature has been done, and the main drainage solutions have been recovered, carrying out an evaluation of them from an environmental point of view. This procedure has been requested by several authors in the past (Nwa, E.U. & Twocock, J.G., 1969; Goulter, I.C., 1992), together with the need of designing a more sustainable drainage system. The final objective of this complete revision is to compare objetively the designs to valuate them in order to develop a new drainage patter which minimize the erosion, increasing the durability and effectiveness of the drainage system. For this purpose, it is neccesary to assure that all the systems will be compare under similar parameters of flow rate, vegetation, substrate, lenght, slope and total section. Only the channels pattern and water distribution will change. The analysis has been done following Liu, H. & Zhu, X.B., (2012), who pointed out that the main parameters to take into account to select a road drainage

  15. Subdural drainage versus subperiosteal drainage in burr-hole trepanation for symptomatic chronic subdural hematomas.

    Science.gov (United States)

    Bellut, David; Woernle, Christoph Michael; Burkhardt, Jan-Karl; Kockro, Ralf Alfons; Bertalanffy, Helmut; Krayenbühl, Niklaus

    2012-01-01

    Symptomatic chronic subdural hematoma (scSDH) is one of the most frequent diseases in neurosurgical practice, and its incidence is increasing. However, treatment modalities are still controversial. The aim of this retrospective single-center study is to compare for the first time two surgical methods in the treatment of subdural hematoma that have been proven to be efficient in previous studies in a direct comparison. We analyzed the data of 143 scSDHs in 113 patients undergoing surgery for subdural hematoma with placement of subperiosteal or subdural drainage after double burr-hole trepanation for hematoma evacuation. Overall, there were no statistically significant differences regarding general patient characteristics, preoperative and postoperative symptoms, postoperative hematoma remnant, rates of recurrences, mortality, complications, and outcome at discharge and at 3-month follow up between the groups. There was a close to significant tendency of lower mortality after placement of subperiosteal drainage system and a tendency towards lower rate of recurrent hematoma after placement of subdural drainage system. Our study shows for the first time a direct comparison of two mainly used surgical techniques in the treatment of scSDH. Both methods proved to be highly effective, and general patient data, complications, outcome and mortality of both groups are equal or superior compared with previously published series. Because there is a clear tendency to less mortality and fewer serious complications, treatment with double burr-hole trepanation, irrigation, and placement of subperiosteal drainage is our treatment of choice in patients with predictable high risk of complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. The occurrence and prevention of Infectious Pancreatic Necrosis Virus (IPNV) in rainbow trout fish farms: the importance of improved sanitary practices

    OpenAIRE

    AGIM REXHEPI; KURTESH SHERIFI; PETER SCHEINERT; LINDA GRAPCI-KOTORRI

    2014-01-01

    The viral diseases of rainbow trout are of worldwide concern including infectious pancreatic necrosis (IPN). On this study good sanitary practices are applied to prevent outbreaks and minimize losses caused from IPN disease. To highlight importance of improvements on sanitary practices in IPN prevention were compared results from two studies, first conducted in year 2006-2009 with results from one year later study conducted in 2010. In year 2010, samples of organs are collected from 260 fish ...

  17. Flooding the sanitary city : Planning discourse and the materiality of urban sanitation in Hanoi

    NARCIS (Netherlands)

    Schramm, S.

    2016-01-01

    Urban water flows are constitutive elements of Hanoi’s morphology. Regular floods across the city illustrate that Hanoi’s amphibious character is a central impediment to the installa- tion of a ‘dry and sanitary city’, the global modernist ideal of a separation of urban waste- water flows from

  18. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  19. Quality prediction of a leached produced in a sanitary landfills

    International Nuclear Information System (INIS)

    Agudelo Garcia, Ruben Alberto; Garcia R, Francisco Fernando; Rivera Mesa, Carolina

    2002-01-01

    This paper presents a mathematical model developed with the purpose of predicting the concentration of pollutants in the leached produced by the biological degradation of the solid wastes disposed in sanitary landfills. The model consists in a kinetic equation of first level, able to describe the degradation of the organic matter being the solid residuals. This model was calibrated using the results obtained from six laboratory scale lysimeters operated under different conditions. The model predicted the concentration of the pollutants in the leached with an accuracy of 94%

  20. Intermediate report on the problems of warm water drainage

    International Nuclear Information System (INIS)

    1976-01-01

    The investigation into the solution of the problems of warm water drainage and its related matters was conducted, and the result was summarized by the warm water drainage sectional committee of the central public nuisance-prevention council entrusted by the Environment Agency. The first section of this report deals with the background of the warm water drainage problems. In December 1970, the environmental pollution prevention act was revised so as to include warm water drainage in the law. The second section deals with the progress of deliberation by the sectional committee. The third section deals with the actual conditions of warm water drainage. The temperature difference at the inlet and outlet of water was 5 to 11 0 C in power plants, 5 to 16 0 C in iron and steel works, 4 to 11 0 C in petroleum refineries, and 7 to 25 0 C in petrochemical plants. The amount of heat energy discharged from power plants was greater than that from the others. Other sections deal with its effects on the living things in water, the forecast of diffusion of warm drainage, the concept of the regulation of warm drainage, and the present countermeasure. Twelve points which require future investigation are listed. They are the change in the phases of living things affected by the change in temperature and flow of warm drainage, the effects on fishery resources, the estimation system for the environmental calorific capacity in the sea, the mechanism of diffusion and the forecasting method for the diffusion range. (Iwakiri, K.)

  1. Development of laundry drainage treatment system with ceramic ultra filter

    International Nuclear Information System (INIS)

    Kanda, Masanori; Kurahasi, Takafumi

    1995-01-01

    A compact laundry drainage treatment system (UF system hereafter) with a ceramic ultra filter membrane (UF membrane hereafter) has been developed to reduce radioactivity in laundry drainage from nuclear power plants. The UF membrane is made of sintered fine ceramic. The UF membrane has 0.01 μm fine pores, resulting in a durable, heat-resistant, and corrosion-resistant porous ceramic filter medium. A cross-flow system, laundry drainage is filtrated while it flows across the UF membrane, is used as the filtration method. This method creates less caking when compared to other methods. The UF membrane is back washed at regular intervals with permeated water to minimize caking of the filter. The UF membrane and cross-flow system provides long stable filtration. The ceramic UF membrane is strong enough to concentrate suspended solids in laundry drainage up to a weight concentration of 10%. The final concentrated laundry drainage can be treated in an incinerator. The performance of the UF system was checked using radioactive laundry drainage. The decontamination factor of the UF system was 25 or more. The laundry drainage treatment capacity and concentration ratio of the UF system, as well as the service life of the UF membrane were also checked by examination using simulated non-radioactive laundry drainage. Even though laundry drainage was concentrated 1000 times, the UF system showed good permeated water quality and permeated water flux. (author)

  2. Proceedings of the international land reclamation and mine drainage conference and third international conference on the abatement of acidic drainage. Volume 1: Mine drainage -- SP 06A-94

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Volume 1 of these proceedings is divided into the following sections: Modeling mine water quality; Water treatment with wetlands; Predicting mine water quality; Water treatment--Chemical; Control of acid mine drainage--Wet covers; Site characterization monitoring; Control of acid mine drainage--Alkaline addition; and Mine water geochemistry. Papers dealing with or applicable to coal or uranium mining have been processed separately for inclusion on the data base

  3. Numerical Three-Dimensional Model of Airport Terminal Drainage System

    Directory of Open Access Journals (Sweden)

    Strzelecki Michał

    2014-03-01

    Full Text Available During the construction of an airport terminal it was found that as a result of the hydrostatic pressure of underground water the foundation plate of the building had dangerously shifted in the direction opposite to that of the gravitational forces. The only effective measure was to introduce a drainage system on the site. The complex geology of the area indicated that two independent drainage systems, i.e., a horizontal system in the Quaternary beds and a vertical system in the Tertiary water-bearing levels, were necessary. This paper presents numerical FEM calculations of the two drainage systems being part of the airport terminal drainaged esign. The computer simulation which was carried out took into consideration the actual effect of the drainage systems and their impact on the depression cone being formed in the two aquifers.

  4. Land drainage and restoration of land after NCB opencast mining

    Energy Technology Data Exchange (ETDEWEB)

    Bragg, N.

    The author outlines the MAFF Field Drainage Research Unit's research into drainage of reinstated land. Current investigations have aimed at identifying the problems of reinstated soil and how they affect drainage design. Experiments on efficiency of permeable field drains and non-permeable field drains are mentioned. Further work is needed to examine long-term effects of storage on soil structure and whether existing drainage can be revitalised by secondary treatment.

  5. Drainage Water Filtration

    Science.gov (United States)

    Tile drainage discharge from managed turf is known to carry elevated concentrations of agronomic fertilizers and chemicals. One approach being considered to reduce the transport is end-of-tile-filters. Laboratory and field studies have been initiated to address the efficacy of this approach. Result...

  6. PROJECTS ON AIRPORTS, AIRFIELDS, HELICOPTER AERODROMES AND LANDING GROUNDS SANITARY PROTECTION AREAS AS THE BASIS OF THEIR ACTIVITY COMPLIANCE ASSESSMENT TO ECOLOGICAL REQUIREMENTS

    Directory of Open Access Journals (Sweden)

    Oleg A. Kartyshev

    2017-01-01

    Full Text Available Ten years experience of the development of domestic airports sanitary protection zones projects in civil aviation based on Sanitary Regulations and Norms 2.2.1/2.1.1.1200-03 requirements is analyzed, the reasons of loss of quality of project works and delaying of coordination terms at the last stage of the development are established. It is shown that among the main reasons for current negative situation with projects development and coordination are: absence of a check algorithm of settlement borders of areas and contours of aviation noise with the use of natural researches methods in Sanitary Regulations and Norms 2.2.1/2.1.1.1200-03; absence of methods of amendment in projects and regulations of establishment of the airport sanitary protection zones final dimensions. Examples of oversized and undersized noise areas and ones of the polluting substances dispersion as well as the reasons of local authorities’ interests in it are given.Conceptional strategies which should be used in the edition of a new Russian conservancy normative document regulating the development of projects on sanitary protection areas. New document will allow to consider various factors of negative environmental impact of the airports, airfields, helicopter aerodromes and landing grounds activities.It is offered to introduce the concept of "aviation noise set index operational card", which will solve the legitimation problem of the aviation noise account in the State Immovable Property Cadaster. Suggestions on equivalent and maximum level magnitude of the sound made at the residential territory of cities and urban-type settlements by flights and aircraft ground operation are given.Standards are supposed to be harmonized with similar international rules and have to provide zone gradation by 5 dBA.Suggestions on the considerations of the revealed deficiencies are made, requirements to project sections structure of sanitary protection zones are formulated, proposals on the

  7. The effect of climate change on urban drainage

    DEFF Research Database (Denmark)

    Grum, M.; Jørgensen, A.T.; Johansen, R.M.

    2006-01-01

    and consequences of climate change on urban drainage and urban runoff pollution issues. This study uses predictions from a regional climate model to look at the effects of climate change on extreme precipitation events. Results are presented in terms of point rainfall extremes. The analysis involves three steps......That we are in a period of extraordinary rates of climate change is today evident. These climate changes are likely to impact local weather conditions with direct impacts on precipitation patterns and urban drainage. In recent years several studies have focused on revealing the nature, extent...... to urban drainage. However, in spite of these uncertainties, and others raised in the discussion, the tendency is clear: extreme precipitation events effecting urban drainage and causing flooding will become more frequent as a result of climate change....

  8. PASSIVE TREATMENT OF ACID ROCK DRAINAGE FROM A SUBSURFACE MINE

    Science.gov (United States)

    Acidic, metal-contaminated drainages are a critical problem facing many areas of the world. Acid rock drainage results when metal sulfide minerals, particularly pyrite, are oxidized by exposure to oxygen and water. The deleterious effects of these drainages on receiving streams a...

  9. Systematic review and meta-analysis of closed suction drainage versus non-drainage in primary hip arthroplasty.

    LENUS (Irish Health Repository)

    Kelly, Enda G

    2014-03-01

    The routine use of drains in surgery has been dogmatically instituted in some disciplines. Orthopaedic surgery is one such sub-speciality. The use of postoperative closed suction drainage in total hip arthroplasty (THA) has become increasingly controversial with multiple randomised control trials performed to assess the benefit to outcome in THA. The hypothesis of this systematic review is that closed suction drainage does not infer a benefit and increase transfusion requirements of primary total hip arthroplasty patients. A systematic review and meta-analysis was conducted adhering to the PRISMA guidelines. A search of the available literature was performed on PubMed, Cochrane Central Registry of Controlled Trials, MEDLINE (OVID) and EMBASE using a combination of MeSH terms and Boolean operators. All data analysis was performed using the Cochrane Collaboration\\'s Review Manager 5.1. Sixteen studies (n=2705) were included in the analysis. Post-operative closed suction drainage was found to increase total blood loss and blood transfusion requirements (p<0.05). Surgical site infection demonstrated no significant difference between the two groups (p=0.82). No significant difference in haematoma formation between groups (p=0.19) was elicited. The routine use of closed suction drainage systems post primary hip arthroplasty is not supported by this meta-analysis. However, the heterogeneity between studies does limit the accuracy of the meta-analysis.

  10. A model to measure lymphatic drainage from the eye.

    Science.gov (United States)

    Kim, Minhui; Johnston, Miles G; Gupta, Neeru; Moore, Sara; Yücel, Yeni H

    2011-11-01

    Intraocular pressure (IOP) is the most important risk factor for glaucoma development and progression. Most anti-glaucoma treatments aim to lower IOP by enhancing aqueous humor drainage from the eye. Aqueous humor drainage occurs via well-characterized trabecular meshwork (TM) and uveoscleral (UVS) pathways, and recently described ciliary body lymphatics. The relative contribution of the lymphatic pathway to aqueous drainage is not known. We developed a sheep model to quantitatively assess lymphatic drainage along with TM and UVS outflows. This study describes that model and presents our initial findings. Following intracameral injection of (125)I-bovine serum albumin (BSA), lymph was continuously collected via cannulated cervical lymphatic vessels and the thoracic lymphatic duct over either a 3-h or 5-h time period. In the same animals, blood samples were collected from the right jugular vein every 15 min. Lymphatic and TM drainage were quantitatively assessed by measuring (125)I-BSA in lymph and plasma, respectively. Radioactive tracer levels were also measured in UVS and "other" ocular tissue, as well as periocular tissue harvested 3 and 5 h post-injection. Tracer recovered from UVS tissue was used to estimate UVS drainage. The amount of (125)I-BSA recovered from different fluid and tissue compartments was expressed as a percentage of total recovered tracer. Three hours after tracer injection, percentage of tracer recovered in lymph and plasma was 1.64% ± 0.89% and 68.86% ± 9.27%, respectively (n = 8). The percentage of tracer in UVS, other ocular and periocular tissues was 19.87% ± 5.59%, 4.30% ± 3.31% and 5.32% ± 2.46%, respectively. At 5 h (n = 2), lymphatic drainage was increased (6.40% and 4.96% vs. 1.64%). On the other hand, the percentage of tracer recovered from UVS and other ocular tissue had decreased, and the percentage from periocular tissue showed no change. Lymphatic drainage increased steadily over the 3 h post-injection period, while TM

  11. Regulated Electric Drainage and its Interference with Track Circuits

    Directory of Open Access Journals (Sweden)

    Vaclav Kolar

    2018-01-01

    Full Text Available Electric drainage is a power electronic device used to protect underground metal devices (such as piping from the corrosive effects of stray currents. Stray currents are usually caused by DC electric traction, such as trams or railways. In places where stray currents leave the underground device and return into rails, they cause significant electrochemical corrosion of buried devices. The principle of electric drainage is based on electrical connection between the underground device and electric traction rails, which ensures that current flows through this connection, instead of flowing into the ground. Nowadays, the most widely used type is regulated electric drainage, where current is regulated by means of Pulse Width Modulation (PWM. Because of this modulation, current flowing through the drainage contains harmonic components with different frequencies. In modern railways, track circuits are often used as an important part of the track security system. For safe operation, it is necessary to ensure that frequencies generated by the drainage do not interfere with track circuits. This paper describes the design of a regulated drainage control system, with regard to its compatibility with track circuits and this paper contains related computer simulations and discussion of the results

  12. Radiologic guidance of drainage of infected and noninfected thoracic fluid collections

    International Nuclear Information System (INIS)

    Van Sonnenberg, E.; Casola, G.; Stavas, J.; Neff, C.C.; Wittich, G.R.; Varney, R.A.; Christensen, R.; Friedman, P.

    1987-01-01

    This exhibit illustrates the spectrum and benefits of radiologic guidance of drainage of 100 thoracic fluid collections. Collections which underwent drainage include: empyemas, lung abscesses, bronchopleural fistulas (BPF), mediastinal abscesses, paracardial collections, bronchogenic cysts, sequestrations, lymphocoeles, malignant effusions, and necrotic tumors. Sclerotherapy catheterization also is described. The modalities for guidance were CT, US, and fluoroscopy. Inadequate thoracostomy tube drainage occurred in a third of the patients prior to radiologic drainage. Drainages were effective in 85% of cases sparing surgery or another thoracostomy tube. Complications occurred in 7% of patients, most being minor and none requiring operation. Pitfalls and caveats are highlighted. Criteria for drainage of lung abscesses and BPF are emphasized, as are techniques and methods of follow-up

  13. Acid mine drainage

    Science.gov (United States)

    Bigham, Jerry M.; Cravotta, Charles A.

    2016-01-01

    Acid mine drainage (AMD) consists of metal-laden solutions produced by the oxidative dissolution of iron sulfide minerals exposed to air, moisture, and acidophilic microbes during the mining of coal and metal deposits. The pH of AMD is usually in the range of 2–6, but mine-impacted waters at circumneutral pH (5–8) are also common. Mine drainage usually contains elevated concentrations of sulfate, iron, aluminum, and other potentially toxic metals leached from rock that hydrolyze and coprecipitate to form rust-colored encrustations or sediments. When AMD is discharged into surface waters or groundwaters, degradation of water quality, injury to aquatic life, and corrosion or encrustation of engineered structures can occur for substantial distances. Prevention and remediation strategies should consider the biogeochemical complexity of the system, the longevity of AMD pollution, the predictive power of geochemical modeling, and the full range of available field technologies for problem mitigation.

  14. Risk factors influencing the pleural drainage volume after transthoracic oesophagectomy.

    Science.gov (United States)

    Kosugi, Shin-ichi; Kanda, Tatsuo; Yajima, Kazuhito; Ishikawa, Takashi; Sakamoto, Kaoru

    2013-06-01

    The objective of this study was to clarify the factors influencing pleural drainage volume after transthoracic oesophagectomy and to determine criteria for the selection of patients who would benefit from the early removal of chest drains. Clinicopathological characteristics of 155 patients who underwent transthoracic oesophagectomy were prospectively collected, and the daily drainage volume of each patient was retrospectively reviewed. Potential risk factors were compared between the high-output group (n = 39) and low-output group (n = 116), which were dichotomized using the 75th percentile of total pleural drainage volume of the total study population. Multivariate logistic regression analyses were used to identify independent risk factors. The median duration of drainage was 10 days, with a median total drainage volume of 2258 ml. Of 27 potential risk factors influencing the drainage volume, creatinine clearance (P = 0.04), operative approach (P = 0.03) and thoracic duct removal (P = 0.01) were significantly associated with the total pleural drainage volume. The removal of the thoracic duct (P = 0.02; odds ratio, 4.02; 95% confidence interval 1.20-13.41) and lower creatinine clearance (P = 0.04; odds ratio, 1.02; 95% confidence interval 1.00-1.04) was independent risk factors for increased pleural drainage volume after transthoracic oesophagectomy. The early removal of chest drains may be possible in patients without these risk factors.

  15. Estimating the benefits of improved drainage on pavement ...

    African Journals Online (AJOL)

    user

    2 Centre for Transportation Systems, Indian Institute of Technology Roorkee, INDIA ... parking lots that only allow cars, not trucks). ..... drainage section) and 2015 & 2019 (for poor drainage section) after the construction of an overlay, it was ...

  16. Acid Mine Drainage Treatment

    National Research Council Canada - National Science Library

    Fripp, Jon

    2000-01-01

    .... Acid mine drainage (AMD) can have severe impacts to aquatic resources, can stunt terrestrial plant growth and harm wetlands, contaminate groundwater, raise water treatment costs, and damage concrete and metal structures...

  17. Agricultural Drainage Well Intakes

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Locations of surface intakes for registered agriculture drainage wells according to the database maintained by IDALS. Surface intakes were located from their...

  18. Remaining Sites Verification Package for the 1607-F3 Sanitary Sewer System, Waste Site Reclassification Form 2006-047

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-04-26

    The 1607-F3 waste site is the former location of the sanitary sewer system that supported the 182-F Pump Station, the 183-F Water Treatment Plant, and the 151-F Substation. The sanitary sewer system included a septic tank, drain field, and associated pipeline, all in use between 1944 and 1965. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River.

  19. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  20. Management of chest drainage tubes after lung surgery.

    Science.gov (United States)

    Satoh, Yukitoshi

    2016-06-01

    Since chest tubes have been routinely used to drain the pleural space, particularly after lung surgery, the management of chest tubes is considered to be essential for the thoracic surgeon. The pleural drainage system requires effective drainage, suction, and water-sealing. Another key point of chest tube management is that a water seal is considered to be superior to suction for most air leaks. Nowadays, the most common pleural drainage device attached to the chest tube is the three-bottle system. An electronic chest drainage system has been developed that is effective in standardizing the postoperative management of chest tubes. More liberal use of digital drainage devices in the postoperative management of the pleural space is warranted. The removal of chest tubes is a common procedure occurring almost daily in hospitals throughout the world. Extraction of the tube is usually done at the end of full inspiration or at the end of full expiration. The tube removal technique is not as important as how it is done and the preparation for the procedure. The management of chest tubes must be based on careful observation, the patient's characteristics, and the operative procedures that had been performed.

  1. Drainage from coal mines: Chemistry and environmental problems

    International Nuclear Information System (INIS)

    Wildeman, T.

    1991-01-01

    Much of the research on coal-mine drainage chemistry was conducted a decade ago, and now increased environmental awareness has brought about renewed interest in the findings. Consideration of the trace minerals and elements in coal points to the possible generation of acidic waters upon weathering, especially when pyrite is present. When pyrite weathers, it produces H + and Fe 3+ which catalyze the incongruent weathering of other carbonates and sulfides. In this weathering mechanism, catalysis by bacteria is important. Of the environmental problems in coal mine drainage, the mineral acidity of the water is the most serious. This is caused not only by the H + , but also by Mn 4+ , Fe 3+ , and Al 3+ that are found or generated within the drainage. Case studies in Kentucky, Pennsylvania, Illinois, and Colorado show that the abundance and form of pyrite in the deposit and in the overburden determines the level of acidity and the concentration of heavy metal pollutants in the drainage. Recent trends in environmental enforcement that emphasize integrated stream water standards and biotoxicity assays point to the possibility that the concentrations of heavy metals in coal mine drainages may cause environmental concern

  2. Methodology for the design of Santa Rosa de Cabal sanitary landfill, Risaralda; Metodologia para el diseno del relleno sanitario de Santa Rosa de Cabal, Risaralda

    Energy Technology Data Exchange (ETDEWEB)

    Tabares, J; Orozco, J

    1992-07-01

    In 1987 the Regional Autonomous Corporation of Risaralda, CARDER and the Risaralda Government, they signed a cooperation agreement, in order to endowing from sanitary landfill to the municipalities of the department. In the mark of this agreement it was carried out the design of Santa Rosa's sanitary landfill, that with near 50.000 inhabitants it is constituted in the third city of the department. This city generates some 25 tons/day of garbage that at the present time are heady directly to the waters of San Eugenio River. The present work contains the most important methodological aspects in the design of the sanitary landfill and some comments about the approaches ideal Vs real approaches of selection of places.

  3. Glaucoma Drainage Device Erosion Following Ptosis Surgery.

    Science.gov (United States)

    Bae, Steven S; Campbell, Robert J

    2017-09-01

    To highlight the potential risk of glaucoma drainage device erosion following ptosis surgery. Case report. A 71-year-old man underwent uncomplicated superotemporal Ahmed glaucoma valve implantation in the left eye in 2008. Approximately 8 years later, the patient underwent bilateral ptosis repair, which successfully raised the upper eyelid position. Three months postoperatively, the patient's glaucoma drainage implant tube eroded through the corneal graft tissue and overlying conjunctiva to become exposed. A graft revision surgery was successfully performed with no further complications. Caution and conservative lid elevation may be warranted when performing ptosis repair in patients with a glaucoma drainage implant, and patients with a glaucoma implant undergoing ptosis surgery should be followed closely for signs of tube erosion.

  4. Dynamic drainage of froth with wood fibers

    Science.gov (United States)

    J.Y. Zhu; Freya Tan

    2005-01-01

    Understanding froth drainage with fibers (or simply called fiber drainage in froth) is important for improving fiber yield in the flotation deinking operation. In this study, the data of water and fiber mass in foams collected at different froth heights were used to reconstruct the time dependent and spatially resolved froth density and fiber volumetric concentration...

  5. Hygienic, sanitary, physical, and functional conditions of Brazilian public school food services

    OpenAIRE

    Almeida,Kênia Machado de; André,Maria Cláudia Porfirio; Campos,Maria Raquel Hidalgo; Díaz,Mário Ernesto Piscoya

    2014-01-01

    OBJECTIVE: To verify the physical, functional, hygienic, and sanitary conditions of the food services of municipal schools located in the Brazilian Midwest region. METHODS: This is a cross-sectional study of 296 school food services conducted from February to June 2012. The food services were assessed by a semi-structured check list divided into the following sections: physical conditions, available equipment, food handlers' conduct, and food service cleaning processes and procedures. Th...

  6. Intermediate-term and long-term outcome of piggyback drainage: connecting glaucoma drainage device to a device in-situ for improved intraocular pressure control.

    Science.gov (United States)

    Dervan, Edward; Lee, Edward; Giubilato, Antonio; Khanam, Tina; Maghsoudlou, Panayiotis; Morgan, William H

    2017-11-01

    This study provides results of a treatment option for patients with failed primary glaucoma drainage device. The study aimed to describe and evaluate the long-term intraocular pressure control and complications of a new technique joining a second glaucoma drainage device directly to an existing glaucoma drainage device termed 'piggyback drainage'. This is a retrospective, interventional cohort study. Eighteen eyes of 17 patients who underwent piggyback drainage between 2004 and 2013 inclusive have been studied. All patients had prior glaucoma drainage device with uncontrolled intraocular pressure. The piggyback technique involved suturing a Baerveldt (250 or 350 mm) or Molteno3 glaucoma drainage device to an unused scleral quadrant and connecting the silicone tube to the primary plate bleb. Failure of intraocular pressure control defined as an intraocular pressure greater than 21 mmHg on maximal therapy on two separate occasions or further intervention to control intraocular pressure. The intraocular pressure was controlled in seven eyes (39%) at last follow-up with a mean follow-up time of 74.2 months. The mean preoperative intraocular pressure was 27.1 mmHg (95% confidence interval 23.8-30.3) compared with 18.4 mmHg (95% confidence interval 13.9-22.8) at last follow-up. The mean time to failure was 57.1 months (95% confidence interval 32.2-82), and the mean time to further surgery was 72.3 months (95% confidence interval 49.9-94.7). Lower preoperative intraocular pressure was associated with longer duration of intraocular pressure control (P = 0.048). If the intraocular pressure was controlled over 2 years, it continued to be controlled over the long term. Two eyes (11%) experienced corneal decompensation. Piggyback drainage represents a viable surgical alternative for the treatment of patients with severe glaucoma with failing primary glaucoma drainage device, particularly in those at high risk of corneal decompensation. © 2017 Royal Australian and New Zealand

  7. The sanitary conditions of food service establishments and food safety knowledge and practices of food handlers in bahir dar town.

    Science.gov (United States)

    Kibret, Mulugeta; Abera, Bayeh

    2012-03-01

    Lack of basic infrastructure, poor knowledge of hygiene and practices in food service establishments can contribute to outbreaks of foodborne illnesses. The aims of this study were to investigate the food safety knowledge and practices of food handlers and to assess the sanitary conditions of food service establishments in Bahir Dar town. A cross-sectional study was conducted in Bahir Dar in May 2011 and data were collected using questionnaire and observation checklist on employees' knowledge of food hygiene and their practices as well on sanitary conditions of the food service establishments The median age of the food handlers was 22 years and among the 455 subjects 99 (21.8%) have had food hygiene training. Sixty six percent of the establishments had flush toilets whereas 5.9% of the establishment had no toilet. Only 149 (33.6%) of the establishments had a proper solid waste collection receptacle and there was statistically significant association between the sanitary conditions and license status of the establishments (p=0.01). Most of all, knowledge gap in food hygiene and handling practice was observed. In addition, there was statistically significant difference between trained (professional) handlers and non-trained handlers with regard to food hygiene practices (p<0.05). While more than 50% of the handlers prepare meals ahead of the peak selling time, more than 50% of the left over was poorly managed. This study revealed poor sanitary conditions and poor food hygiene practices of handlers. Educational programs targeted at improving the attitude of food handlers and licensing and regular inspections have been recommended.

  8. Streamflow distribution maps for the Cannon River drainage basin, southeast Minnesota, and the St. Louis River drainage basin, northeast Minnesota

    Science.gov (United States)

    Smith, Erik A.; Sanocki, Chris A.; Lorenz, David L.; Jacobsen, Katrin E.

    2017-12-27

    Streamflow distribution maps for the Cannon River and St. Louis River drainage basins were developed by the U.S. Geological Survey, in cooperation with the Legislative-Citizen Commission on Minnesota Resources, to illustrate relative and cumulative streamflow distributions. The Cannon River was selected to provide baseline data to assess the effects of potential surficial sand mining, and the St. Louis River was selected to determine the effects of ongoing Mesabi Iron Range mining. Each drainage basin (Cannon, St. Louis) was subdivided into nested drainage basins: the Cannon River was subdivided into 152 nested drainage basins, and the St. Louis River was subdivided into 353 nested drainage basins. For each smaller drainage basin, the estimated volumes of groundwater discharge (as base flow) and surface runoff flowing into all surface-water features were displayed under the following conditions: (1) extreme low-flow conditions, comparable to an exceedance-probability quantile of 0.95; (2) low-flow conditions, comparable to an exceedance-probability quantile of 0.90; (3) a median condition, comparable to an exceedance-probability quantile of 0.50; and (4) a high-flow condition, comparable to an exceedance-probability quantile of 0.02.Streamflow distribution maps were developed using flow-duration curve exceedance-probability quantiles in conjunction with Soil-Water-Balance model outputs; both the flow-duration curve and Soil-Water-Balance models were built upon previously published U.S. Geological Survey reports. The selected streamflow distribution maps provide a proactive water management tool for State cooperators by illustrating flow rates during a range of hydraulic conditions. Furthermore, after the nested drainage basins are highlighted in terms of surface-water flows, the streamflows can be evaluated in the context of meeting specific ecological flows under different flow regimes and potentially assist with decisions regarding groundwater and surface

  9. Properties of the subglacial till inferred from supraglacial lake drainage

    Science.gov (United States)

    Neufeld, J. A.; Hewitt, D.

    2017-12-01

    The buildup and drainage of supraglacial lakes along the margins of the Greenland ice sheet has been previously observed using detailed GPS campaigns which show that rapid drainage events are often preceded by localised, transient uplift followed by rapid, and much broader scale, uplift and flexure associated with the main drainage event [1,2]. Previous models of these events have focused on fracturing during rapid lake drainage from an impermeable bedrock [3] or a thin subglacial film [4]. We present a new model of supraglacial drainage that couples the water flux from rapid lake drainage events to a simplified model of the pore-pressure in a porous, subglacial till along with a simplified model of the flexure of glacial ice. Using a hybrid mathematical model we explore the internal transitions between turbulent and laminar flow throughout the evolving subglacial cavity and porous till. The model predicts that an initially small water flux may locally increase pore-pressure in the till leading to uplift and a local divergence in the ice velocity that may ultimately be responsible for large hydro-fracturing and full-scale drainage events. Furthermore, we find that during rapid drainage while the presence of a porous, subglacial till is crucial for propagation, the manner of spreading is remarkably insensitive to the properties of the subglacial till. This is in stark contrast to the post-drainage relaxation of the pore pressure, and hence sliding velocity, which is highly sensitive to the permeability, compressibility and thickness of subglacial till. We use our model, and the inferred sensitivity to the properties of the subglacial till after the main drainage event, to infer the properties of the subglacial till. The results suggest that a detailed interpretation of supraglacial lake drainage may provide important insights into the hydrology of the subglacial till along the margins of the Greenland ice sheet, and the coupling of pore pressure in subglacial till

  10. Discussion of 10 CRF 20 rules for waste of effluents in sanitary sewerage

    International Nuclear Information System (INIS)

    Rocha, A.C.S. da; Pina, J.L.S.

    1986-12-01

    An interpretation of the Code of Federal Regulations, volume 10 part 20 (10 CFR 20) from Nuclear Regulatory Commission is proposed, aiming at his easier use in waste of radioactive liquid effluents to the environment, by sanitary sewerage. The study is based on recommendations of International Commission of Radiological Protection (ICPR 2) and International Atomic Energy Agency (Basic Safety Standards for Radiation Protection). (M.A.C.) [pt

  11. Treatment of dyeing drainage by radiation

    International Nuclear Information System (INIS)

    Shimokawa, Toshinari; Sawai, Takeshi

    1985-01-01

    Decolorization of artificial dyeing drainage and sewage by radiation treatment. Artifical dyeing drainage was prepared from water, polyvinyl alcohol, starch, urea and several kinds of inorganic salts, and artificial sewage, from water, peptone, broth, urea and several kinds of inorganic salts. The above mentioned sample liquors of artificial dyeing drainage and sewage were exposed to γ-radiation of 5 kCi of 60 Co source by aerating through a ball filter. Absorption spectra, total organic carbon (TOC) and chemical oxygen demand (COD) were determined after irradiation to evaluate radiation treatment effect. With the experimental data obtained, it was clarified that absorbance, COD and TOC was decreased with the increase of absorbed dose. Decoloring was made effectively and about 95 % of bleaching ratio was obtained at 5 kGy of radiation. COD was decreased also by irradiation rather slower decreasing rate than that of decolorization, and TOC decrease was very slow at the initial stage of radiation but 40 % of TOC was decomposed by 10 kGy radiation. Dye of chemically stable structure was found more resistant to radiation decolorization. Decomposition efficiency was found less for dyes in the artificial sewage but secondary treated sewage showed no adverse effect. With the obtained understandings, a tentative scheme was planned for the radiation decolorization of dyeing drainage after aeration treatment. (Takagi, S.)

  12. Preoperative biliary drainage for pancreatic cancer.

    Science.gov (United States)

    Van Heek, N T; Busch, O R; Van Gulik, T M; Gouma, D J

    2014-04-01

    This review is to summarize the current knowledge about preoperative biliary drainage (PBD) in patients with biliary obstruction caused by pancreatic cancer. Most patients with pancreatic carcinoma (85%) will present with obstructive jaundice. The presence of toxic substances as bilirubin and bile salts, impaired liver function and altered nutritional status due to obstructive jaundice have been characterized as factors for development of complications after surgery. Whereas PBD was to yield beneficial effects in the experimental setting, conflicting results have been observed in clinical studies. The meta-analysis from relative older studies as well as more importantly a recent clinical trial showed that PBD should not be performed routinely. PBD for patients with a distal biliary obstruction is leading to more serious complications compared with early surgery. Arguments for PBD have shifted from a potential therapeutic benefit towards a logistic problem such as patients suffering from cholangitis and severe jaundice at admission or patients who need extra diagnostic tests, or delay in surgery due to a referral pattern or waiting list for surgery as well as candidates for neoadjuvant chemo(radio)therapy. If drainage is indicated in these patients it should be performed with a metal stent to reduce complications after the drainage procedure such as stent occlusion and cholangitis. Considering a change towards more neoadjuvant therapy regimes improvement of the quality of the biliary drainage concept is still important.

  13. The main trends of interaction of sanitary-epidemiological teams in the system of the Russian service of disaster medicine in emergency situations

    International Nuclear Information System (INIS)

    Zaichenko, A.I.; Zhuravleva, V.E.; Varenikov, I.I.; Komarova, V.V.; Borisov, B.K.; Pozhidaev, A.E.; Pozhidaeva, N.V.

    1995-01-01

    For improvement of the system of prevention of emergency situations (ES) and for rendering emergency therapeutic-prophylactic and sanitary-epidemiological aid to population in case of ES the paper has determined and proved the first and foremost tasks which are to be settled by joint efforts of the Russian Centre on Disaster Medicine Zashchita and Scientific-practical Center of hygienic expert survey for practical perfection of the efficient forms of interaction of medical-sanitary forces engaged in work in ES. 4 refs

  14. Role of Lithology and Rock Structure in Drainage Development in ...

    African Journals Online (AJOL)

    Lithology and Rock structure play a vital role in the development of Drainage Network in any drainage basin. The drainage patterns upon land surface develop as directed by the underlying lithology and rock structure. In fact, lithology and rock structure together shape the basin and are decisive parameters of nature and ...

  15. Gravitational shunt units may cause under-drainage in bedridden patients.

    Science.gov (United States)

    Kaestner, S; Kruschat, T; Nitzsche, N; Deinsberger, W

    2009-03-01

    Implantation of a shunt in a hydrocephalic patient still carries a risk of complications such as over-drainage and under-drainage. Gravitational shunt units are especially designed to minimize the problem of over-drainage. Nevertheless, these valves carry a risk of under-drainage. The best choice of valve for a patient is still challenging. The purpose of this survey was to identify in which patients a gravitational shunt valve is liable to lead to under-drainage. Patients with hydrocephalus entered prospectively into a data base were reviewed retrospectively. The patients were treated between January 2006 to the end of Feb 2007 and those experiencing under- or over-drainage were identified. Thirty-five ventriculo-peritoneal shunt systems were implanted in adult patients. The cause of the hydrocephalus was: normal pressure hydrocephalus in 18 patients, post-haemorrhagic following subarachnoid or intracerebral haemorrhage in 11, associated with a tumour in four and followed a head injury in two patients. Three different valves were used: an adjustable shunt valve with gravitational unit (Pro-GAV 0-20/25 in 21 patients), a gravitational shunt valve with fixed opening pressure (GAV 5/30 in nine patients) and an adjustable differential valve (Hakim medos in five patients). Four patients developed severe, valve-related under-drainage. Each had received a gravitational shunt valve and all were bedridden. In two of these patients it was necessary to change the valve. One patient who had received a differential valve, after regaining mobility developed severe over-drainage with bilateral subdural haematomas. Over-drainage was not seen in long-term bedridden patients with a differential shunt valve. If a bedridden patient with a gravitational shunt valve system lies with a slightly elevated head, this leads to activation of the gravitational unit and this may cause under drainage. As a result, we advise not using an anti-siphon devices in a patient who is bedridden for a

  16. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  17. Endoscopic Ultrasound-guided Drainage of Pancreatic Pseudocysts

    DEFF Research Database (Denmark)

    Ng, Pui Yung; Nytoft Rasmussen, Ditlev; Vilmann, Peter

    2013-01-01

    or by telephonic interview. RESULTS: A total of 61 procedures were performed. The symptoms that indicated drainage were abdominal pain (n = 43), vomiting (n = 7) and jaundice (n = 5). The procedure was technically successful in 57 of the 61 procedures (93%). The immediate complication rate was 5%. At a mean follow......-up of 45 weeks, the treatment success was 75%. The medium term complications appeared in 25% of cases, which included three cases each of stent clogging, stent migration, infection and six cases of recurrence. There was no mortality. CONCLUSION: EUS-guided drainage is an effective treatment for PPC...... with a successful outcome in most of patients. Most of the complications require minimal invasive surgical treatment or repeated EUS-guided drainage procedures....

  18. Profile of thoracic trauma victims submitted to chest drainage

    Directory of Open Access Journals (Sweden)

    CESAR AUGUSTO BROSKA JÚNIOR

    Full Text Available ABSTRACT Objective: to describe and compare the variables involved in trauma victims undergoing thoracic drainage. Methods: we conducted a retrospective, analytical, descriptive, cross-sectional study, with medical records of patients attended at the Trauma Service of the Curitiba Evangelical University Hospital between February 2011 and January 2014. Results: there were 488 patients undergoing chest drainage, 84.7% men and 15.3% women, with an average age of 38.2 years. Attendances usually occurred at night, without predominance between open or closed mechanism, gender or age group. The majority of patients with thoracic trauma requiring drainage were diagnosed by anamnesis and physical examination (41.1% and drained in the emergency room (80.8%. Most of the patients (66.2% had another associated lesion, mostly some abdominal viscera. Complications were present in 16.6% (81 patients, most of them due to drainage positioning error (9.2%. The mean hospital stay was 15 days and drainage lasted for an average of 8.1 days, with no statistical difference between open and closed trauma. The clinical outcome was discharge in most cases. Conclusion: the profile of patients with thoracic trauma is that of young men, attended at night, with some other associated lesion. Although diagnosis and treatment were rapid and most often without the need for complex examinations, the time of drainage, hospitalization and complications were higher than in the literature, which can be explained by the drainage being made at the Emergency Room and the presence of associated injuries.

  19. Scintigraphy of the lacrimal drainage system

    International Nuclear Information System (INIS)

    Denffer, H. von; Dressler, J.; Technische Univ. Muenchen

    1978-01-01

    A new scintigraphic method, the radionuclide dacryography, to evaluate lacrimal drainage and its disorders is described. A drop of sup(99m)Tc-pertechnetate is dropped onto the eyes and the transport of the nuclide is registered by a scintillation camera. By this method it is easy to verify, under physiological conditions, suspected obstructions of the lacrimal drainage system and to determine its localization. The absorbed radiation dose using radionuclide dacryography is very low as compared to radiological methods. (orig.) [de

  20. Menstruation and the Cycle of Poverty: A Cluster Quasi-Randomised Control Trial of Sanitary Pad and Puberty Education Provision in Uganda.

    Science.gov (United States)

    Montgomery, Paul; Hennegan, Julie; Dolan, Catherine; Wu, Maryalice; Steinfield, Laurel; Scott, Linda

    2016-01-01

    Poor menstrual knowledge and access to sanitary products have been proposed as barriers to menstrual health and school attendance. In response, interventions targeting these needs have seen increasing implementation in public and private sectors. However, there has been limited assessment of their effectiveness. Assess the impact of providing reusable sanitary pads and puberty education on girls' school attendance and psychosocial wellbeing outcomes. A cluster quasi-randomised controlled trial was conducted across 8 schools, including 1124 girls, in rural Uganda. Schools were allocated to one of four conditions: the provision of puberty education alone; reusable sanitary pads alone; puberty education and reusable sanitary pads; and a control (no intervention). The primary outcome was school attendance. Secondary outcomes reflected psychosocial wellbeing. At follow-up, school attendance had worsened for girls across all conditions. Per-protocol analysis revealed that this decline was significantly greater for those in the control condition d = 0.52 (95%CI 0.26-0.77), with those in control schools having a 17.1% (95%CI: 8.7-25.5) greater drop in attendance than those in any intervention school. There were no differences between the intervention conditions. High rates of school drop-out and transfer meant the trial suffered from substantial participant drop-out. Intention-to-treat analyses using two different imputation strategies were consistent with the main results, with mean differences of 5.2% attendance in best-case and 24.5% in worst-case imputations. Results were robust to adjustments for clustering. There was no impact of the interventions on girls' self-reported shame or insecurity during menstruation. Results of the trial support the hypothesised positive impact of providing sanitary pads or puberty education for girls' school attendance in a developing country context. Findings must be interpreted with caution in light of poor participant retention

  1. Menstruation and the Cycle of Poverty: A Cluster Quasi-Randomised Control Trial of Sanitary Pad and Puberty Education Provision in Uganda.

    Directory of Open Access Journals (Sweden)

    Paul Montgomery

    Full Text Available Poor menstrual knowledge and access to sanitary products have been proposed as barriers to menstrual health and school attendance. In response, interventions targeting these needs have seen increasing implementation in public and private sectors. However, there has been limited assessment of their effectiveness.Assess the impact of providing reusable sanitary pads and puberty education on girls' school attendance and psychosocial wellbeing outcomes.A cluster quasi-randomised controlled trial was conducted across 8 schools, including 1124 girls, in rural Uganda. Schools were allocated to one of four conditions: the provision of puberty education alone; reusable sanitary pads alone; puberty education and reusable sanitary pads; and a control (no intervention. The primary outcome was school attendance. Secondary outcomes reflected psychosocial wellbeing.At follow-up, school attendance had worsened for girls across all conditions. Per-protocol analysis revealed that this decline was significantly greater for those in the control condition d = 0.52 (95%CI 0.26-0.77, with those in control schools having a 17.1% (95%CI: 8.7-25.5 greater drop in attendance than those in any intervention school. There were no differences between the intervention conditions. High rates of school drop-out and transfer meant the trial suffered from substantial participant drop-out. Intention-to-treat analyses using two different imputation strategies were consistent with the main results, with mean differences of 5.2% attendance in best-case and 24.5% in worst-case imputations. Results were robust to adjustments for clustering. There was no impact of the interventions on girls' self-reported shame or insecurity during menstruation.Results of the trial support the hypothesised positive impact of providing sanitary pads or puberty education for girls' school attendance in a developing country context. Findings must be interpreted with caution in light of poor participant

  2. Menstruation and the Cycle of Poverty: A Cluster Quasi-Randomised Control Trial of Sanitary Pad and Puberty Education Provision in Uganda

    Science.gov (United States)

    Montgomery, Paul; Hennegan, Julie; Dolan, Catherine; Wu, Maryalice; Steinfield, Laurel; Scott, Linda

    2016-01-01

    Background Poor menstrual knowledge and access to sanitary products have been proposed as barriers to menstrual health and school attendance. In response, interventions targeting these needs have seen increasing implementation in public and private sectors. However, there has been limited assessment of their effectiveness. Objectives Assess the impact of providing reusable sanitary pads and puberty education on girls’ school attendance and psychosocial wellbeing outcomes. Methods A cluster quasi-randomised controlled trial was conducted across 8 schools, including 1124 girls, in rural Uganda. Schools were allocated to one of four conditions: the provision of puberty education alone; reusable sanitary pads alone; puberty education and reusable sanitary pads; and a control (no intervention). The primary outcome was school attendance. Secondary outcomes reflected psychosocial wellbeing. Results At follow-up, school attendance had worsened for girls across all conditions. Per-protocol analysis revealed that this decline was significantly greater for those in the control condition d = 0.52 (95%CI 0.26–0.77), with those in control schools having a 17.1% (95%CI: 8.7–25.5) greater drop in attendance than those in any intervention school. There were no differences between the intervention conditions. High rates of school drop-out and transfer meant the trial suffered from substantial participant drop-out. Intention-to-treat analyses using two different imputation strategies were consistent with the main results, with mean differences of 5.2% attendance in best-case and 24.5% in worst-case imputations. Results were robust to adjustments for clustering. There was no impact of the interventions on girls’ self-reported shame or insecurity during menstruation. Conclusion Results of the trial support the hypothesised positive impact of providing sanitary pads or puberty education for girls’ school attendance in a developing country context. Findings must be interpreted

  3. Drainage Behavior in Soap Films Above and Below the CMC

    Science.gov (United States)

    Berg, S.; Adelizzi, E. A.; Troian, S. M.

    2003-11-01

    We investigate through laser interferometry the drainage behavior of Newtonian soap films initially entrained on a fiber frame at small and constant capillary number. The initial film thickness is sufficiently small that gravitational drainage is presumed minimal. The drainage of rigid soap films by capillary forces alone should proceed according to h(t) ˜ t^- 1/2. Our experimental results show much more rapid drainage with exponents as large as -2, especially for those solutions whose surfactant concentrations are below the CMC. Video recordings of the entire film surface reveal a variety of structures during the drainage process, some attributable to marginal regeneration. Though still a controversial issue, this regeneration process is believed to be caused by surfactant accumulation in the meniscus region (1). We show that modification of the relevant capillary drainage equation to account for Marangoni effects through a course-grained slip condition at the air-liquid interface produces exponents in better agreement with experimental findings. (1) V. A. Nierstrasz and G. Frens, JCIS 215, 28 (1999).

  4. Lower incidence of complications in endoscopic nasobiliary drainage for hilar cholangiocarcinoma.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Haba, Shin; Kudo, Taiki; Taya, Yoko A; Kawahata, Shuhei; Kubota, Yoshimasa; Kubo, Kimitoshi; Eto, Kazunori; Ehira, Nobuyuki; Yamato, Hiroaki; Onodera, Manabu; Sakamoto, Naoya

    2016-05-10

    To identify the most effective endoscopic biliary drainage technique for patients with hilar cholangiocarcinoma. In total, 118 patients with hilar cholangiocarcinoma underwent endoscopic management [endoscopic nasobiliary drainage (ENBD) or endoscopic biliary stenting] as a temporary drainage in our institution between 2009 and 2014. We retrospectively evaluated all complications from initial endoscopic drainage to surgery or palliative treatment. The risk factors for biliary reintervention, post-endoscopic retrograde cholangiopancreatography (post-ERCP) pancreatitis, and percutaneous transhepatic biliary drainage (PTBD) were also analyzed using patient- and procedure-related characteristics. The risk factors for bilateral drainage were examined in a subgroup analysis of patients who underwent initial unilateral drainage. In total, 137 complications were observed in 92 (78%) patients. Biliary reintervention was required in 83 (70%) patients. ENBD was significantly associated with a low risk of biliary reintervention [odds ratio (OR) = 0.26, 95%CI: 0.08-0.76, P = 0.012]. Post-ERCP pancreatitis was observed in 19 (16%) patients. An absence of endoscopic sphincterotomy was significantly associated with post-ERCP pancreatitis (OR = 3.46, 95%CI: 1.19-10.87, P = 0.023). PTBD was required in 16 (14%) patients, and Bismuth type III or IV cholangiocarcinoma was a significant risk factor (OR = 7.88, 95%CI: 1.33-155.0, P = 0.010). Of 102 patients with initial unilateral drainage, 49 (48%) required bilateral drainage. Endoscopic sphincterotomy (OR = 3.24, 95%CI: 1.27-8.78, P = 0.004) and Bismuth II, III, or IV cholangiocarcinoma (OR = 34.69, 95%CI: 4.88-736.7, P hilar cholangiocarcinoma is challenging. ENBD should be selected as a temporary drainage method because of its low risk of complications.

  5. Timing of drainage tube removal after thyroid surgery: a retrospective study.

    Science.gov (United States)

    Minami, Shigeki; Sakimura, Chika; Hayashida, Naomi; Yamanouchi, Kosho; Kuroki, Tamotsu; Eguchi, Susumu

    2014-01-01

    The aim of this study was to evaluate the chronological changes in the amount of drainage fluid after thyroidectomy, and to establish standard indications for the drain to be removed. We examined a cohort of 249 patients undergoing thyroid surgery. The patients were divided into four groups: a Graves' group, a non-dissection group, a central-dissection group and a lateral-dissection group. The amount of drainage was measured every 6 h, and the drain was removed postoperatively when the drainage decreased in amount and contained serous fluid after a meal. In all four groups, the most drainage occurred in the first 6 h after surgery. The total amount of drainage from the operation to the time of drain removal was significantly higher in Graves' group and in the lateral-dissection group than in the other two groups. The median wound drainage significantly decreased from 12 to 18 h after surgery in all four groups. In the lateral-dissection group, the wound drainage significantly decreased again in the first 24-30 h. The findings of this study suggest that drains can be removed postoperatively if the drainage was less than 15 mL during a 6-h period and contain serous fluid.

  6. Time effects of water drainage from deposited back-fill

    International Nuclear Information System (INIS)

    Baranski, L.A.

    1976-01-01

    Time effects of water drainage from deposited back-fill in mine excavations are considered. The time dependence of drainage from the deposited material was determined from ''in situ'' measurements with the aid of radioisotope gauges. The measurements were performed for given drainage conditions and practically constant grain size composition. It was found that in a few hours after the end of the back-filling operation the mechanical properties of the deposited material are practically constant. (author)

  7. Accelerating transient drainage from UMTRA Project tailings piles

    International Nuclear Information System (INIS)

    1990-09-01

    The period between the completion of construction of the tailings disposal cell and the establishment of equilibrium moisture content and seepage conditions is considered to be the period of transient drainage. Transient drainage may be due to factors such as construction water, precipitation, or residual water from the milling process. Transient seepage rates usually exceed steady state seepage rates. If the transient seepage rate causes contaminant levels to exceed groundwater compliance standards, then an alternative groundwater compliance strategy or technical approach to reduce or mitigate the effects of the drainage must be adopted. This study examines methods to accelerate the transient drainage of soils and hence to remove excess pore water from tailings in UMTRA Project disposal cells. The technical and economic feasibility of possible methods is examined. In order to perform comparative economical analyses of the various methods, an example tailings pile is postulated. This pile is considered to be 300 meters by 300 meters by 10 meters in thickness

  8. Runway drainage characteristics related to tire friction performance

    Science.gov (United States)

    Yager, Thomas J.

    1991-01-01

    The capability of a runway pavement to rapidly drain water buildup during periods of precipitation is crucial to minimize tire hydroplaning potential and maintain adequate aircraft ground operational safety. Test results from instrumented aircraft, ground friction measuring vehicles, and NASA Langley's Aircraft Landing Dynamics Facility (ALDF) track have been summarized to indicate the adverse effects of pavement wetness conditions on tire friction performance. Water drainage measurements under a range of rainfall rates have been evaluated for several different runway surface treatments including the transversely grooved and longitudinally grinded concrete surfaces at the Space Shuttle Landing Facility (SLF) runway at NASA Kennedy Space Center in Florida. The major parameters influencing drainage rates and extent of flooding/drying conditions are identified. Existing drainage test data are compared to a previously derived empirical relationship and the need for some modification is indicated. The scope of future NASA Langley research directed toward improving empirical relationships to properly define runway drainage capability and consequently, enhance aircraft ground operational safety, is given.

  9. Municipal solid wastes (RSU) treatment in land filled controlled: Of its sanitary problems to energy production

    International Nuclear Information System (INIS)

    Urzola C, R.A.

    1995-01-01

    Excessive world wastes production generates constant preoccupations with relation to its management. The methods of classic elimination as sanitary landfill controlled as compared to controvertible incineration and gasification plants as well as expectations created in connection with practices of recycling, its are intensive discussions motive between town halls, technical specialists, ecologists and general public. What is certain is that wastes in the last 30 years have been valued economically. Today the wastes are appreciated by certain sectors that begin to monopolize the recycling line because they see an excellent business. All methods of residues elimination produce at same time other wastes. Solid nature wastes generally end in the landfill and semi-liquid waste are dehydrated with same objective. In the present Thesis, without intending to say that the landfill processing will be the better option, is outlined the form of optimizing the utilization of same. It's demonstrated that landfill, furthermore to fulfil its sanitary function, are converted into an energetic alternative with utilization of flammable gas generated in them, something which represents an interesting value added if is converted into source of welfare for social and economically kernels, as happens in peripheries of the sanitary landfill at large Latin American cities. Of other side are considered principal aspects that intervene in methane gas generation and quality and utilization alternatives. Finally it is made emphasis in environmental situation at European and international level about the landfill gases, how is outlined greenhouse effect topic, what are environmental actions for year 2000 and are related some biogas utilization experiences at Europe

  10. Drainage filters and constructed wetlands to mitigate sitespecific nutrient losses

    DEFF Research Database (Denmark)

    Kjærgaard, Charlotte; Canga, Eriona; Heckrath, Goswin Johann

    2012-01-01

    Research Council, aims at providing the scientific basis for developing cost-effective filter technologies targeting P-retention and N-removal in agricultural subsurface drainage. The project studies different approaches of implementing the filter technologies including drainage well filters as well...... typically applied to point sources. This calls for a shift of paradigm towards the development of new, cost-efficient technologies to mitigate site-specific nutrient losses in drainage. A newly launched Danish research project “SUPREME-TECH” (2010-2015) (www.supreme-tech.dk) funded by the Danish Strategic...... in drainage water to below environmental threshold values (

  11. Percutaneous catheter drainage of pancreatic pseudocysts

    International Nuclear Information System (INIS)

    Karnel, F.; Gebauer, A.; Jantsch, H.; Prayer, L.; Schurawitzki, H.; Feil, W.

    1991-01-01

    The results of CT/US-guided percutaneous drainage in 35 patients with pancreatic pseudocysts are reported. 27 patients recovered without surgery and no further treatment was required. 8 patients required a subsequent surgery due to recurrence. The role of CT/US-guided percutaneous drainage in pancreatic pseudocysts as well as an analysis of the technical aspects associated with a successful procedure are discussed. Although US may be used, we believe CT is safer and allows more precise localisation and guidance in the treatment of pseudocysts. (orig.) [de

  12. Surface Water & Surface Drainage

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This data set contains boundaries for all surface water and surface drainage for the state of New Mexico. It is in a vector digital data structure digitized from a...

  13. Efficacy of incision and drainage versus percutaneous catheter drainage in treatment of severe acute pancreatitis complicated by pancreatic abscess

    Directory of Open Access Journals (Sweden)

    YANG Feng

    2016-03-01

    Full Text Available ObjectiveTo investigate the clinical features and treatment of severe acute pancreatitis (SAP complicated by pancreatic abscess (PA. MethodsThe clinical data of 17 SAP patients with PA who were admitted to Affiliated Hospital of Luzhou Medical College from January 1, 2005 to August 25, 2015 were analyzed retrospectively. The clinical manifestations, therapeutic methods, and outcome were summarized. ResultsOf all the 17 patients, 12 patients underwent surgical operation, among whom 9 were cured, 1 experienced postoperative intestinal fistula, and 2 experienced recurrence of abscess and underwent the surgery again (1 died of multiple organ failure, and the mean hospital stay was (108.29±52.37 d; 5 patients underwent percutaneous catheter drainage, among whom 4 were cured, and 1 underwent surgical treatment due to inadequate drainage, and the mean hospital stay was (53.03±6.71 d. ConclusionAdequate drainage should be performed once a confirmed diagnosis of PA is made, and appropriate drainage methods should be selected based on the patient′s actual condition. Minimally invasive treatment has a good effect, a short length of hospital stay, and few complications, and holds promise for clinical application.

  14. Do general dental practitioners leave teeth on 'open drainage'?

    Science.gov (United States)

    Eliyas, S; Barber, M W; Harris, I

    2013-12-01

    There is a need to ascertain the use of evidence-based dentistry in both primary and secondary care in order to tailor education. This study aims to evaluate the use of 'open drainage' as part of endodontic treatment in primary care in South Yorkshire. A questionnaire was circulated to 141 randomly selected general dental practitioners in the South Yorkshire area between January 2012 and January 2013. The response rate was 79% (112/141). Five of the returned questionnaires were incomplete and therefore not usable. Seventy-nine percent of respondents were general dental practitioners (GDPs) working in mainly NHS or mixed practices. The year of graduation varied between 1970 and 2011. Forty-one percent (44/107) stated that they had never left a tooth on open drainage. Twenty-nine percent (31/107) stated that they sometimes leave teeth on open drainage. Of those respondents who currently leave teeth on open drainage, most (68%) would leave teeth on open drainage for one to two days or less. This survey revealed that the practice of leaving teeth on open drainage is still present in general dental practice. Current guidelines do not comment on the use of this treatment modality. There is a need to ascertain further information about practices throughout the United Kingdom in order to provide clear evidence-based guidelines.

  15. EFFECTIVENESS OF AUTOGENIC DRAINAGE VERSUS POSTURAL DRAINAGE ON OXYGEN SATURATION IN PATIENTS WITH CHRONIC BRONCHITIS WITH 15 MINUTES POST THERAPY

    Directory of Open Access Journals (Sweden)

    V. Kiran

    2014-12-01

    Full Text Available Background: Patients with COPD will have more amount of secretions. To clear the secretions by using of different bronchial hygiene techniques like postural drainage and autogenic drainage technique, manual hyperventilation technique ,active cycle breathing technique .Hence in this study to compare the short-term effects of postural drainage with clapping (PD and autogenic drainage (AD on level of oxygen saturation in blood, and amount of sputum recovery. Methodology: The study was done on 60 patients with COPD. Dividing Patients into two group and patients were treated with PD or AD in separate Groups. The effectiveness of the treatment was measured up to 6 days. Pulse oximetry was monitored and sputum was collected immediately after treatment and 15 minutes following each treatment. Results: The results of the study shown that there was significant difference in the amount of sputum recovered with AD (14.0±3.5 g vs PD (24.4±3.0 g and significant differences in Oxygen saturation; during PD fell from 93.3±0.7% to 91.2±0.8% (p<0.01 and required 15 min following treatment to return to baseline. Oxygen saturation did not fall during AD and increased to gradually following complete treatment days (baseline, 93.3±0.8%; p<0.01. Conclusion: Hence this study concludes that Autogenic drainage is more effective in improving spo2 in COPD & does not cause a sudden fall in spo2 as occurs in Postural drainage immediately after therapy. And it can be better tolerated by patients with COPD while producing fewer benefits in sputum clearance. In concern to mean amount of secretion removal Postural is found to be more effective

  16. Extra environmental impact assessment and recommendable measures for their minimization in arranging sanitary inspection room site

    International Nuclear Information System (INIS)

    Rud'ko, V.M.; Batij, V.G.; Kuz'menko, V.A.; Paskevich, S.A.

    2003-01-01

    Environmental impact assessments during the works for preparation of sanitary inspection room site are presented. A range of measures to minimize environmental impact from the works to be implemented,is offered. Impacts on such environmental components as soil,air and aqueous medium,are considered

  17. Bronchoscopic drainage of a malignant lung abscess.

    Science.gov (United States)

    Katsenos, Stamatis; Psathakis, Konstantinos; Chatzivasiloglou, Fotini; Antonogiannaki, Elvira-Markela; Psara, Anthoula; Tsintiris, Konstantinos

    2015-04-01

    Bronchoscopic drainage of a pyogenic lung abscess is an established therapeutic approach in selected patients in whom conventional antibiotic therapy fails. This intervention has also been undertaken in patients with abscess owing to underlying lung cancer and prior combined radiochemotherapy. However, this procedure has rarely been performed in cavitary lesions of advanced tumor origin before initiating any chemotherapy/radiotherapy scheme. Herein, we describe a case of a 68-year-old woman with lung adenocarcinoma stage IIIB, who underwent bronchoscopic drainage of necrotizing tumor lesion, thus improving her initial poor clinical condition and rendering other treatment modalities, such as radiotherapy, more effective and beneficial. Bronchoscopic drainage of a symptomatic cancerous lung abscess should be considered as an alternative and palliative treatment approach in patients with advanced inoperable non-small cell lung cancer.

  18. Hygienic, sanitary, physical, and functional conditions of Brazilian public school food services

    Directory of Open Access Journals (Sweden)

    Kênia Machado de Almeida

    2014-06-01

    Full Text Available OBJECTIVE: To verify the physical, functional, hygienic, and sanitary conditions of the food services of municipal schools located in the Brazilian Midwest region. METHODS: This is a cross-sectional study of 296 school food services conducted from February to June 2012. The food services were assessed by a semi-structured check list divided into the following sections: physical conditions, available equipment, food handlers' conduct, and food service cleaning processes and procedures. The study variables were classified as compliant or noncompliant with the regulations passed by the National Sanitary Surveillance Agency. RESULTS: Noncompliances were found in all study food services, especially with respect to food service conditions, and the wiring and plumbing in the food preparation area. In this section, 62.7 to 95.9% of the food services did not comply with nine out of the thirteen study items. The main problems were: poorly cleaned external areas, deteriorated walls, floors, ceilings, roofs, drains, and roof gutters; and unscreened doors and windows, allowing the entrance of insects; among others. The main noncompliance regarding processes and procedures was the uncontrolled temperature of the ready-to-eat foods. CONCLUSION: The conditions of the study food services are unsatisfactory for the production of safe meals, possibly compromising meal quality, food safety, and the effectiveness of the School Food Program.

  19. [The information on a sanitary-and-epidemiologic condition of general educational establishments and catering services of schoolboys].

    Science.gov (United States)

    Onishchenko, G G

    2008-01-01

    The federal service on supervision in sphere of protection of the rights of consumers and well-being of the person develops normative and methodical documents, including sanitary rules and the norms defining hygienic parameters of food value of food raw material and foodstuff, children used in a feed and teenagers; requirements to catering services of pupils of various types of teaching and educational establishments. Decisions of the Main state health officer of the Russian Federation, the conditions directed on improvement and catering services in educational establishments are published. At participation of Rospotrebnadzor's experts on subjects of the Russian Federation the regional programs directed on improvement of catering services of pupils are developed. The information on a condition of general educational establishments with offers on improvement of a sanitary-engineering condition, goes to address of enforcement authorities.

  20. Evaluation of sanitary consequences of Chernobylsk accident in France. Epidemiological surveillance plan, state of knowledge, risks evaluation and perspectives

    International Nuclear Information System (INIS)

    Verger, P.; Cherie-Challine, L.

    2000-12-01

    This report jointly written by IPSN and InVS, reviews the sanitary consequences in France of the Chernobyl accident, which occurred in 1986. The first point is dedicated to a short presentation of the knowledge relative to the sanitary consequences of the Chernobyl accident in the high contaminated countries and to the risk factors of the thyroid cancer. Secondly, this report describes the main systems of epidemiological surveillance of health implemented in France in 1986 and in 1999, as well as the data of the incidence and mortality of thyroid cancer observed in France since 1975. In addition, this report presents an analysis of the risk of thyroid cancer related to radioactive contamination in France, for young people of less than 15 years of age who where living in 1986 in the highest contaminated areas of France (Eastern territories). For this purpose, the theoretical number of thyroid cancers in excess is evaluated for this population, on the basis of different available risk model. Finally starting from the results of risk assessment, there is a discussion about the relevance and the feasibility of different epidemiological methods in view of answering the questions related to the sanitary consequences of the Chernobyl accident. In conclusion, this report recommends to reinforce the surveillance of thyroid cancer in France. (author)

  1. Drainage areas of the Potomac River basin, West Virginia

    Science.gov (United States)

    Wiley, Jeffrey B.; Hunt, Michelle L.; Stewart, Donald K.

    1996-01-01

    This report contains data for 776 drainage-area divisions of the Potomac River Basin, from the headwaters to the confluence of the Potomac River and the Shenandoah River. Data, compiled in downstream order, are listed for streams with a drainage area of approximately 2 square miles or larger within West Virginia and for U.S. Geological Survey streamflow-gaging stations. The data presented are the stream name, the geographical limits in river miles, the latitude and longitude of the point, the name of the county, and the 7 1/2-minute quadrangle in which the point lies, and the drainage area of that site. The total drainage area of the Potomac River Basin downstream of the confluence of the Shenandoah River at the State boundary is 9,367.29 square miles.

  2. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): Design and rationale of a randomized controlled trial

    NARCIS (Netherlands)

    J.K. Wiggers (Jimme K.); R.J. Coelen (Robert J.); E.A.J. Rauws (Erik); O.M. van Delden (Otto); C.H.J. van Eijck (Casper); J. de Jonge (Jeroen); R.J. Porte (Robert); C.I. Buis (Carlijn I.); C.H. Dejong (Cees); I.Q. Molenaar (I. Quintus); M.G. Besselink (Marc); O.R.C. Busch (Olivier); M.G.W. Dijkgraaf (Marcel); T.M. van Gulik (Thomas)

    2015-01-01

    textabstractBackground: Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be

  3. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): design and rationale of a randomized controlled trial

    NARCIS (Netherlands)

    Wiggers, Jimme K.; Coelen, Robert J. S.; Rauws, Erik A. J.; van Delden, Otto M.; van Eijck, Casper H. J.; de Jonge, Jeroen; Porte, Robert J.; Buis, Carlijn I.; Dejong, Cornelis H. C.; Molenaar, I. Quintus; Besselink, Marc G. H.; Busch, Olivier R. C.; Dijkgraaf, Marcel G. W.; van Gulik, Thomas M.

    2015-01-01

    Background: Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when

  4. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial) : design and rationale of a randomized controlled trial

    NARCIS (Netherlands)

    Wiggers, Jimme K.; Coelen, Robert J. S.; Rauws, Erik A. J.; van Delden, Otto M.; van Eijck, Casper H. J.; de Jonge, Jeroen; Porte, Robert J.; Buis, Carlijn I.; Dejong, Cornelis H. C.; Molenaar, I. Quintus; Besselink, Marc G. H.; Busch, Olivier R. C.; Dijkgraaf, Marcel G. W.; van Gulik, Thomas M.

    2015-01-01

    Background: Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when

  5. Treating mediastinoesophageal fistula with covered stent through nasal esophagus drainage tube

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Li Yongdong; Ma Nan; Wang Yanli; Gao Xuemei

    2005-01-01

    Objective: To investigate the value of treating mediastinoesophageal fistula with covered stent through nasal esophagus drainage tube. Methods: Ten patients with mediastinoesophageal fistula were treated by 5F catheter inserting into the abscess cavities through nasal esophageal fistula, with stent placement in the esophagus. The abscess cavities were washed and angiograghied through drainage tube and the sites of the drainage tube were adjusted in time until withdrawal of the tube. Results: The drainage tubes were pulled out within 10-25 days with disappearance of the abscess cavities and normal diet intake without difficulty. Conclusions: Treating mediastinoesophageal fistula with covered stent through nasal esophagus drainage tube is safe, microinvasive economic and acceptable, worth to be recommended. (authors)

  6. 46 CFR 173.062 - Drainage of weather deck.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Drainage of weather deck. 173.062 Section 173.062 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSEL USE School Ships § 173.062 Drainage of weather deck. The weather deck of each sailing...

  7. Remote Hemorrhage after Burr Hole Drainage of Chronic Subdural Hematoma.

    Science.gov (United States)

    Kim, Chang Hyeun; Song, Geun Sung; Kim, Young Ha; Kim, Young Soo; Sung, Soon Ki; Son, Dong Wuk; Lee, Sang Weon

    2017-10-01

    Chronic subdural hematoma (CSDH) and symptomatic subdural hygroma are common diseases that require neurosurgical management. Burr hole trephination is the most popular surgical treatment for CSDH and subdural hygroma because of a low recurrence rate and low morbidity compared with craniotomy with membranectomy, and twist-drill craniotomy. Many reports suggest that placing a catheter in the subdural space for drainage can further reduce the rate of recurrence; however, complications associated with this type of drainage include acute subdural hematoma, cortical injury, and infection. Remote hemorrhage due to overdrainage of cerebrospinal fluid (CSF) is another possible complication of burr hole trephination with catheter drainage that has rarely been reported. Here, we present 2 cases of remote hemorrhages following burr hole trephination with catheter drainage for the treatment of CSDH and symptomatic subdural hygroma. One patient developed intracerebral hemorrhage and subarachnoid hemorrhage in the contralateral hemisphere, while another patient developed remote hemorrhage 3 days after the procedure due to the sudden drainage of a large amount of subdural fluid over a 24-hour period. These findings suggest that catheter drainage should be carefully monitored to avoid overdrainage of CSF after burr hole trephination.

  8. Autogenic drainage for airway clearance in cystic fibrosis.

    Science.gov (United States)

    McCormack, Pamela; Burnham, Paul; Southern, Kevin W

    2017-10-06

    Autogenic drainage is an airway clearance technique that was developed by Jean Chevaillier in 1967. The technique is characterised by breathing control using expiratory airflow to mobilise secretions from smaller to larger airways. Secretions are cleared independently by adjusting the depth and speed of respiration in a sequence of controlled breathing techniques during exhalation. The technique requires training, concentration and effort from the individual. It is important to systematically review the evidence demonstrating that autogenic drainage is an effective intervention for people with cystic fibrosis. To compare the clinical effectiveness of autogenic drainage in people with cystic fibrosis with other physiotherapy airway clearance techniques. We searched the Cochrane Cystic Fibrosis Trials Register, compiled from electronic database searches and handsearching of journals and conference abstract books. We also searched the reference lists of relevant articles and reviews, as well as two trials registers (31 August 2017).Dtae of most recent search of the Cochrane Cystic Fibrosis Trials Register: 25 September 2017. We identified randomised and quasi-randomised controlled studies comparing autogenic drainage to another airway clearance technique or no therapy in people with cystic fibrosis for at least two treatment sessions. Data extraction and assessments of risk of bias were independently performed by two authors. The authors assessed the quality of the evidence using the GRADE system. The authors contacted two investigators for further information pertinent to their published studies. Searches retrieved 35 references to 21 individual studies, of which seven (n = 208) were eligible for inclusion. One study was of parallel design with the remaining six being cross-over in design; participant numbers ranged from 17 to 75. The total study duration varied between four days and two years. The age of participants ranged between seven and 63 years with a wide

  9. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. Pancreatic tissue fluid pressure during drainage operations for chronic pancreatitis

    DEFF Research Database (Denmark)

    Ebbehøj, N; Borly, L; Madsen, P

    1990-01-01

    Pancreatic tissue fluid pressure was measured in 10 patients undergoing drainage operations for painful chronic pancreatitis. The pressure was measured by the needle technique in the three anatomic regions of the pancreas before and at different stages of the drainage procedure, and the results...... were compared with preoperative endoscopic retrograde cholangiopancreatography (ERCP) morphology. The preoperatively elevated pressure decreased in all patients but one, to normal or slightly elevated values. The median pressure decrease was 50% (range, 0-90%; p = 0.01). The drainage anastomosis (a...... a decrease in pancreatic tissue fluid pressure during drainage operations for pain in chronic pancreatitis. Regional pressure decrease were apparently unrelated to ERCP findings....

  11. Evaluation of the sanitary impact of urban air pollution. Update version of the methodological guide; Evaluation de l'impact sanitaire de la pollution atmospherique urbaine. Version actualisee du guide methodologique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-15

    In order to bring a help to the evaluation of effects of air quality on health, the Institute of Sanitary surveillance published in 1999 a method guide for the realisation of sanitary impact evaluations of the urban air pollution. This work to prepare to an update version of the guide presents the first recommendations that can be made today for the realisation of sanitary impact evaluations at short and long term at a local level, taking into account the knowledge evolution. (N.C.)

  12. Conceptual model elaboration for the safety assessment of phosphogypsum use in sanitary landfills

    International Nuclear Information System (INIS)

    Cota, Stela D.; Braga, Leticia T.P.; Jacomino, Vanusa F.

    2009-01-01

    Phosphogypsum is a by-product of the phosphatic fertilizer production from the beneficiation of phosphate minerals (apatites). Produced in large quantities throughout the world and stored temporally in stacks, the final destination of this product is nowadays a subject of investigation. Due to the presence of radionuclides ( 226 Ra, 232 Th and 40 K, mainly), possible applications for the phosphogypsum must be verified for radiological safety. The goal of this paper was to elaborate a representative water flow conceptual model of a sanitary landfill for the safety assessment of the impact of using phosphogypsum as a cover material. For this, the ground water flow in variably saturated conditions and solute transport model HYDRUS-2D has been used for simulating the impact in the saturated zone of potential radionuclides leaching. The conceptual model was developed by collecting and analyzing the data from environmental license documentation of municipal sanitary landfills located on the State of Minas Gerais, Brazil. In order to fulfill the requirements of HDRUS-2D model in terms of the necessary parameters, the physical characteristics and typical configuration of the landfills, as well as the hydrogeological parameters of soils and aquifers related to the local of placement of the landfills, were taken in account for the formulation of the conceptual model. (author)

  13. Coupling between drainage and coarsening in wet foam

    Indian Academy of Sciences (India)

    Abstract. Drainage and coarsening are two coupled phenomena during the evolution of wet foam. We show the variation in the growth rate of bubble size, along the height in a column of Gillette shaving foam, by microscope imaging. Simultaneously, the drainage of liquid at the same heights has been investigated by ...

  14. Cholescintigraphy in patients with acute cholecystitis before and after percutaneous gallbladder drainage

    DEFF Research Database (Denmark)

    Borly, L; Stage, J G; Grønvall, S

    1995-01-01

    gallbladder drainage. During the post-drainage cholescintigraphies, a cholecystokinin stimulation was performed to investigate gallbladder emptying in 12 selected patients. Gallbladder pressure and volume were measured before drainage in another group of 12 patients with acute cholecystitis. RESULTS......OBJECTIVE: To investigate gallbladder function by use of cholescintigraphy in patients with acute cholecystitis before and after percutaneous gallbladder drainage. DESIGN: A cholescintigraphy was performed in 40 patients with acute cholecystitis before and after the performance of percutaneous......: As expected, no gallbladder activity was observed in the cholescintigraphies before drainage, except in a patient with an occluding stone in the common bile duct. Cystic duct patency and gallbladder activity were seen in 80% of patients in cholescintigraphies performed after drainage but before any other...

  15. Digital database architecture and delineation methodology for deriving drainage basins, and a comparison of digitally and non-digitally derived numeric drainage areas

    Science.gov (United States)

    Dupree, Jean A.; Crowfoot, Richard M.

    2012-01-01

    The drainage basin is a fundamental hydrologic entity used for studies of surface-water resources and during planning of water-related projects. Numeric drainage areas published by the U.S. Geological Survey water science centers in Annual Water Data Reports and on the National Water Information Systems (NWIS) Web site are still primarily derived from hard-copy sources and by manual delineation of polygonal basin areas on paper topographic map sheets. To expedite numeric drainage area determinations, the Colorado Water Science Center developed a digital database structure and a delineation methodology based on the hydrologic unit boundaries in the National Watershed Boundary Dataset. This report describes the digital database architecture and delineation methodology and also presents the results of a comparison of the numeric drainage areas derived using this digital methodology with those derived using traditional, non-digital methods. (Please see report for full Abstract)

  16. 13 Morphometric Analysis of Ogunpa and Ogbere Drainage Basins ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    form and process of drainage basins that may be widely ... ferruginous tropical soil on basement complex rock (Areola ... landuse pattern control the infiltration loss, the distribution of ... the water intercepted by Ogbere drainage basin to longer ...

  17. MULTI-CRITERIA APPROACH FOR DESIGNING SUSTAINABLE DRAINAGE IN MALANG RESIDENTIAL AREA INDONESIA

    Directory of Open Access Journals (Sweden)

    HAPSARI Ratih Indri

    2016-07-01

    Full Text Available Environmentally sound approach for sustainable urban drainage could promote infiltration and lower the risk of flooding. This study presents the framework to evaluate the drainage alternatives considering multiple aspects including water quantity, life cycle cost and amenity. This approach is verified through application at a residential area in Malang city Indonesia. Different combinations of drainage components comprising of drainage channels, infiltration wells and biopore absorption holes are assessed regarding runoff reduction, present value of life cycle cost, and willingness to pay for the convenience. The first part describes the effective designs of sustainable drainage components in the houses as well as in the public spaces of the housing. The second part of this study describes the use of analytic hierarchy process for weight assignment of sustainability criteria and multiple benefit calculation. The study recommends infiltration wells and biopore absorption holes together with drainage channels as the best management practice of sustainable drainage system based on its overall sustainability index.

  18. Managing a chest tube and drainage system.

    Science.gov (United States)

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  19. Determinants of Nitrous Oxide Emission from Agricultural Drainage Waters

    International Nuclear Information System (INIS)

    Reay, D. S.; Edwards, A. C.; Smith, K. A.

    2004-01-01

    Emissions of the powerful greenhouse gas nitrous oxide (N 2 O) from agricultural drainage waters are poorly quantified and its determinants are not fully understood. Nitrous oxide formation in agricultural soils is known to increase in response to N fertiliser application, but the response of N 2 O in field drainage waters is unknown. This investigation combined an intensive study of the direct flux of N 2 O from the surface of a fertilised barley field with measurement of dissolved N 2 O and nitrate (NO 3 ) concentrations in the same field's drainage waters. Dissolved N 2 O in drainage waters showed a clear response to field N fertilisation, following an identical pattern to direct N 2 O flux from the field surface. The range in N 2 O concentrations between individual field drains sampled on the same day was large, indicating considerable spatial variability exists at the farm scale. A consistent pattern of very rapid outgassing of the dissolved N 2 O in open drainage ditches was accentuated at a weir, where increased turbulence led to a clear drop in dissolved N 2 O concentration. This study underlines the need for carefully planned sampling campaigns wherever whole farm or catchment N 2 O emission budgets are attempted. It adds weight to the argument for the downward revision of the IPCC emission factor (EF 5 -g) for NO 3 in drainage waters

  20. Determinants of nitrous oxide emission from agricultural drainage waters

    International Nuclear Information System (INIS)

    Reay, D. S.; Edwards, A. C.; Smith, K. A.

    2005-01-01

    Emissions of the powerful greenhouse gas nitrous oxide (N 2 O) from agricultural drainage waters are poorly quantified and its determinants are not fully understood. Nitrous oxide formation in agricultural soils is known to increase in response to N fertiliser application, but the response of N 2 O in field drainage waters is unknown. This investigation combined an intensive study of the direct flux of N 2 O from the surface of a fertilised barley field with measurement of dissolved N 2 O and nitrate (NO 3 ) concentrations in the same field's drainage waters. Dissolved N 2 O in drainage waters showed a clear response to field N fertilisation, following an identical pattern to direct N 2 O flux from the field surface. The range in N 2 O concentrations between individual field drains sampled on the same day was large, indicating considerable spatial variability exists at the farm scale. A consistent pattern of very rapid outgassing of the dissolved N 2 O in open drainage ditches was accentuated at a weir, where increased turbulence led to a clear drop in dissolved N 2 O concentration. This study underlines the need for carefully planned sampling campaigns wherever whole farm or catchment N 2 O emission budgets are attempted. It adds weight to the argument for the downward revision of the IPCC emission factor (EF 5 -g) for NO 3 in drainage waters

  1. Lymphatic drainage and sentinel node location in breast cancer

    International Nuclear Information System (INIS)

    Uren, R.F.; Howman-Giles, R.B.; Roberts, J.; Renwick, S.; Gillett, D.; Neische, F.; Ramsay-Stewart, G.

    1999-01-01

    Full text: Mammary lymphoscintigraphy using small volume (0.1-0.2 ml) peritumoral injections of 99 Tc m -antimony sulphide colloid provided a map of the lymph drainage of a breast cancer to its draining sentinel lymph nodes in 92 of 102 patients (over 90%). Non-migration of tracer is reduced by post-injection massage for 5 min but may occur especially if the lymphatics are blocked by metastases. Drainage included the axilla in 92%, internal mammary nodes in 43%, supraclavicular nodes in 12% and intramammary interval nodes in 10% of patients. One patient drained to an interpectoral node. Drainage across the centre-line of the breast occurred in 46% of patients but direct drainage to the contralateral side of the patient was not seen. Lymphatic drainage occurred to 1 node field in 52 patients, 2 node fields in 34 patients and 3 node fields in 6 patients, so that 43% of patients had multiple draining node fields. Drainage to non-axillary sites occurred in 51% of patients. In conclusion, mammary lymphoscintigraphy accurately maps sentinel node location in breast cancer. Approximately half of the patients will have sentinel nodes outside the axilla. To achieve complete lymph node staging in patients with breast cancer, it is logical to biopsy these non-axillary sentinel nodes as well as the sentinel nodes in the axilla. Failure to do so will potentially understage the node status in 50% of patients

  2. Internal drainage of infected pancreatic pseudocysts: safe or sorry?

    NARCIS (Netherlands)

    Boerma, D.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    1999-01-01

    BACKGROUND: External drainage is the traditional surgical therapy for infected pancreatic pseudocyst, although associated with high morbidity and mortality rates. In this study it was determined whether internal drainage is feasible with acceptable postoperative morbidity and recurrence rates.

  3. Percutaneous drainage in conservative therapy for perforated gastroduodenal ulcers.

    Science.gov (United States)

    Oida, Takatsugu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao

    2012-01-01

    The management of peptic ulcers has dramatically changed and the incidence of elective surgery for gastroduodenal peptic ulcers has markedly decreased; hence, the incidence of emergency surgery for perforated peptic ulcers has slightly increased. In select cases, conservative therapy can be used as an alternative for treating perforated gastroduodenal ulcers. In this study, we evaluated the efficacy of percutaneous abdominal drainage for the conservative treatment of perforated gastroduodenal ulcers. We retrospectively studied 51 patients who had undergone conservative therapy for perforated gastroduodenal ulcers. These patients were divided into 2 groups on the basis of the initial treatment with conservative therapy with or without percutaneous drainage: group PD included patients who had undergone percutaneous drainage and group NPD, patients who had undergone non-percutaneous drainage. In the PD group, 14.3% (n=3) of the patients did not respond to conservative therapy, while this value was 43.3% (n=13) in the NPD group. The 2 groups differed significantly with respect to conversion from conservative therapy to surgery (pperforated gastroduodenal ulcers should be performed only in the case of patients meeting the required criteria; its combination with percutaneous intraperitoneal drainage is effective as initial conservative therapy.

  4. [The impact of preoperative biliary drainage on surgical morbidity in hilar cholangiocarcinoma patients].

    Science.gov (United States)

    Li, Shao-qiang; Chen, Dong; Liang, Li-jian; Peng, Bao-gang; Yin, Xiao-yu

    2009-08-01

    To evaluate the impact of preoperative biliary drainage on surgical morbidity in hilar cholangiocarcinoma patients underwent surgery. One hundred and eleven consecutive patients with hilar cholangiocarcinoma whose serum total bilirubin (TBIL) level > 85 micromol/L and underwent surgery in the period from June 1998 to August 2007 were enrolled. There were 67 male and 44 female patients, aged from 26 to 82 years old with a mean of 56 years old. Fifty-five patients underwent preoperative biliary drainage with a mean of 11.4 d of drainage period (drainage group), the other (n = 56) were the non-drainage group. The preoperative TBIL level of drainage group was (154 +/- 69) micromol/L, which was significantly lower than the value of pre-drainage (256 +/- 136) micromol/L (P = 0.000) and the value of non-drainage group (268 +/- 174) micromol/L (P = 0.005). ALT and GGT levels could be lowered by preoperative biliary drainage. The postoperative complications of these two groups were comparable (36.3% vs. 28.6%, P = 0.381). Four patients in drainage group and 5 patients in non-drainage group died of liver failure. Multivariate logistic regression indicated that hepatectomy (OR = 0.284, P = 0.003) was the independent risk factor associated with postoperative morbidity. Bismuth-Corlette classification (OR = 0.211, P = 0.028) was the independent risk factor linked to postoperative mortality. Preoperative biliary drainage could alleviate liver injury due to hyperbilirubin, but it could not decrease the surgical morbidity and postoperative mortality. Concomitant hepatectomy and Bismuth-Corlette classification were independent risk factors linked to surgical risks.

  5. Environmental impact assessment on the construction and operation of municipal solid waste sanitary landfills in developing countries: China case study.

    Science.gov (United States)

    Yang, Na; Damgaard, Anders; Lü, Fan; Shao, Li-Ming; Brogaard, Line Kai-Sørensen; He, Pin-Jing

    2014-05-01

    An inventory of material and energy consumption during the construction and operation (C&O) of a typical sanitary landfill site in China was calculated based on Chinese industrial standards for landfill management and design reports. The environmental impacts of landfill C&O were evaluated through life cycle assessment (LCA). The amounts of materials and energy used during this type of undertaking in China are comparable to those in developed countries, except that the consumption of concrete and asphalt is significantly higher in China. A comparison of the normalized impact potential between landfill C&O and the total landfilling technology implies that the contribution of C&O to overall landfill emissions is not negligible. The non-toxic impacts induced by C&O can be attributed mainly to the consumption of diesel used for daily operation, while the toxic impacts are primarily due to the use of mineral materials. To test the influences of different landfill C&O approaches on environmental impacts, six baseline alternatives were assessed through sensitivity analysis. If geomembranes and geonets were utilized to replace daily and intermediate soil covers and gravel drainage systems, respectively, the environmental burdens of C&O could be mitigated by between 2% and 27%. During the LCA of landfill C&O, the research scope or system boundary has to be declared when referring to material consumption values taken from the literature; for example, the misapplication of data could lead to an underestimation of diesel consumption by 60-80%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Pancreatic tissue fluid pressure during drainage operations for chronic pancreatitis

    DEFF Research Database (Denmark)

    Ebbehøj, N; Borly, L; Madsen, P

    1990-01-01

    Pancreatic tissue fluid pressure was measured in 10 patients undergoing drainage operations for painful chronic pancreatitis. The pressure was measured by the needle technique in the three anatomic regions of the pancreas before and at different stages of the drainage procedure, and the results...... a decrease in pancreatic tissue fluid pressure during drainage operations for pain in chronic pancreatitis. Regional pressure decrease were apparently unrelated to ERCP findings....

  7. 76 FR 35215 - Notice of EPA Workshop on Sanitary Sewer Overflows and Peak Wet Weather Discharges

    Science.gov (United States)

    2011-06-16

    ... maintained sanitary sewer systems are meant to collect and transport all of the sewage that flows into them... sewage from these overflows can contaminate our waters, causing serious water quality problems. It can... influent flows to exceed the treatment capacity of existing secondary treatment units. Known as ``peak...

  8. Drainage of pleural effusion improves diaphragmatic function in mechanically ventilated patients.

    Science.gov (United States)

    Umbrello, Michele; Mistraletti, Giovanni; Galimberti, Andrea; Piva, Ilaria R; Cozzi, Ottavia; Formenti, Paolo

    2017-03-01

    Pleural effusion adversely affects the pressuregenerating capacity of the diaphragm. It uncouples the lung and chest wall, which may result in diaphragmatic dysfunction. Information on the effects of effusion drainage on diaphragmatic function is limited, but several studies report relief of dyspnoea after drainage, which was attributed to improved diaphragmatic mechanics, even if this issue was never formally addressed. To investigate the effect of drainage of unilateral pleural effusion on diaphragmatic function. In a prospective twostep protocol (at baseline and after drainage of effusion), we conducted a spontaneous breathing trial in fourteen critically ill, mechanically ventilated patients undergoing pressure support ventilation. We used ultrasonography of the ipsilateral hemidiaphragm to evaluate and record respiratory displacement and thickening during tidal and maximal breathing efforts. We recorded and analysed airway pressures, respiratory system compliance, vital capacity, indices of respiratory effort and arterial blood gases. After drainage of the effusion, the respiratory rate decreased and tidal volume increased, but haemodynamic parameters were unaffected and oxygenation levels showed a non-significant increase. Drainage was associated with significant decreases in indices of respiratory drive and the maximal pressure generated by the respiratory muscles, as well as an increased compliance of the respiratory system. Diaphragmatic displacement and thickening significantly increased after drainage. We found there was a significant correlation between the volume of the effusion drained and the increase in tidal diaphragmatic thickening. Drainage of a unilateral pleural effusion during weaning from mechanical ventilation improves diaphragmatic contractile activity and respiratory system performance.

  9. Biliary drainage strategy of unresectable malignant hilar strictures by computed tomography volumetry.

    Science.gov (United States)

    Takahashi, Ei; Fukasawa, Mitsuharu; Sato, Tadashi; Takano, Shinichi; Kadokura, Makoto; Shindo, Hiroko; Yokota, Yudai; Enomoto, Nobuyuki

    2015-04-28

    To identify criteria for predicting successful drainage of unresectable malignant hilar biliary strictures (UMHBS) because no ideal strategy currently exists. We examined 78 patients with UMHBS who underwent biliary drainage. Drainage was considered effective when the serum bilirubin level decreased by ≥ 50% from the value before stent placement within 2 wk after drainage, without additional intervention. Complications that occurred within 7 d after stent placement were considered as early complications. Before drainage, the liver volume of each section (lateral and medial sections of the left liver and anterior and posterior sections of the right liver) was measured using computed tomography (CT) volumetry. Drained liver volume was calculated based on the volume of each liver section and the type of bile duct stricture (according to the Bismuth classification). Tumor volume, which was calculated by using CT volumetry, was excluded from the volume of each section. Receiver operating characteristic (ROC) analysis was performed to identify the optimal cutoff values for drained liver volume. In addition, factors associated with the effectiveness of drainage and early complications were evaluated. Multivariate analysis showed that drained liver volume [odds ratio (OR) = 2.92, 95%CI: 1.648-5.197; P < 0.001] and impaired liver function (with decompensated liver cirrhosis) (OR = 0.06, 95%CI: 0.009-0.426; P = 0.005) were independent factors contributing to the effectiveness of drainage. ROC analysis for effective drainage showed cutoff values of 33% of liver volume for patients with preserved liver function (with normal liver or compensated liver cirrhosis) and 50% for patients with impaired liver function (with decompensated liver cirrhosis). The sensitivity and specificity of these cutoff values were 82% and 80% for preserved liver function, and 100% and 67% for impaired liver function, respectively. Among patients who met these criteria, the rate of effective drainage

  10. Predicting success of catheter drainage in infected necrotizing pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; Van Brunschot, Sandra; Bakker, Olaf J.; Ali, Usama Ahmed; Van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; Van Santvoort, Hjalmar C.

    2016-01-01

    Introduction: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. Methods: This was a

  11. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, R.A.; Bollen, T.L.; Brunschot, S. van; Bakker, O.J.; Ali, U. Ahmed; Goor, H. van; Boermeester, M.A.; Gooszen, H.G.; Besselink, M.G.; Santvoort, H.C. van

    2016-01-01

    INTRODUCTION: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. METHODS: This was a

  12. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  13. 76 FR 34145 - Safety Zone, Barrier Testing Operations, Chicago Sanitary and Ship Canal, Romeoville, IL

    Science.gov (United States)

    2011-06-13

    ...-AA00 Safety Zone, Barrier Testing Operations, Chicago Sanitary and Ship Canal, Romeoville, IL AGENCY.... Construction on Barrier IIB has been completed. Operational and safety testing was conducted in February 2011... dispersal barrier IIA and IIB. This safety zone will be enforced daily from 7 a.m. to 11 a.m. and from 1 p.m...

  14. INVESTIGATION OF SANITARY-HYGIENIC CHARACTERISTICS OF MULTILAYER POLYMER FILMS USED FOR VACUUM PACKAGING MODIFIED BY NATIVE ANTIMICROBIAL COMPONENTS

    Directory of Open Access Journals (Sweden)

    O. B. Fedotova

    2016-01-01

    Full Text Available The results of the research works related to investigation of sanitary-hygienic characteristics of multilayer polymer film materials where the inner layer contacting directly with food product is modified by native antimicrobial components.

  15. Remote sensing revealed drainage anomalies and related tectonics of South India

    Science.gov (United States)

    Ramasamy, SM.; Kumanan, C. J.; Selvakumar, R.; Saravanavel, J.

    2011-03-01

    Drainages have characteristic pattern and life histories with youthful stage in hilly areas, mature stage in plains and old stage in the coastal zones. The deviations from their normal life histories, especially aberrations in their flow pattern in the form of various drainage anomalies have been inferred to be the indications of dominantly the Eustatic and Isostatic changes. This, especially after the advent of Earth Observing Satellites, has attracted the geoscientists from all over the world, for studying such drainage anomalies. In this connection, a study has been undertaken in parts of South India falling south of 14° south latitude to comprehensively map some drainage anomalies like deflected drainages, eyed drainages and compressed meanders and to evolve the tectonic scenario therefrom. The mapping of such mega drainage anomalies and the related lineaments/faults from the satellite digital data and the integration of such lineaments/faults with the overall lineament map of South India showed that the study area is marked by active N-S block faults and NE-SW sinistral and NW-SE dextral strike slip faults. Such an architecture of active tectonic grains indicates that the northerly directed compressive force which has originally drifted the Indian plate towards northerly is still active and deforming the Indian plate.

  16. A cost comparison of traditional drainage and SUDS in Scotland.

    Science.gov (United States)

    Duffy, A; Jefferies, C; Waddell, G; Shanks, G; Blackwood, D; Watkins, A

    2008-01-01

    The Dunfermline Eastern Expansion (DEX) is a 350 ha mixed development which commenced in 1996. Downstream water quality and flooding issues necessitated a holistic approach to drainage planning and the site has become a European showcase for the application of Sustainable Urban Drainage Systems (SUDS). However, there is minimal data available regarding the real costs of operating and maintaining SUDS to ensure they continue to perform as per their design function. This remains one of the primary barriers to the uptake and adoption of SUDS. This paper reports on what is understood to be the only study in the UK where actual costs of constructing and maintaining SUDS have been compared to an equivalent traditional drainage solution. To compare SUDS costs with traditional drainage, capital and maintenance costs of underground storage chambers of analogous storage volumes were estimated. A whole life costing methodology was then applied to data gathered. The main objective was to produce a reliable and robust cost comparison between SUDS and traditional drainage. The cost analysis is supportive of SUDS and indicates that well designed and maintained SUDS are more cost effective to construct, and cost less to maintain than traditional drainage solutions which are unable to meet the environmental requirements of current legislation. (c) IWA Publishing 2008.

  17. Prolonged pericardial drainage using a soft drain reduces pericardial effusion and need for additional pericardial drainage following orthotopic heart transplantation.

    Science.gov (United States)

    Kim, Yun Seok; Jung, Sung-Ho; Cho, Won Chul; Yun, Sung-Cheol; Park, Jeong-Jun; Yun, Tae-Jin; Kim, Jae-Joong; Lee, Jae Won

    2016-03-01

    Pericardial effusion can cause haemodynamic compromise after heart transplantation. We identified the effects of soft drains on the development of pericardial effusion. We enrolled 250 patients ≥17 years of age who underwent heart transplantation between July 1999 and April 2012 and received two conventional tubes (n = 96; 32 French), or two tubes with a soft drain (n = 154; 4.8 mm wide). The development of significant pericardial effusion or the need for drainage procedure during 1 month after heart transplantation was compared with the use of the propensity score matching method to adjust for selection bias. At 1 month after transplantation, 69 patients (27.6%) developed significant pericardial effusion. Among these, 13 patients (5.2%) underwent pericardial drainage. According to multivariate analysis, history of previous cardiac surgery [odds ratio (OR) = 0.162; 95% confidence interval (CI) = 0.046-0.565; P = 0.004] and placement of a soft drain (OR = 0.186; 95% CI = 0.100-0.346; P effusion or the need for drainage during the early postoperative period. For the 82 propensity score matched pairs, patients receiving an additional soft drain were at a lower risk of the development of significant pericardial effusion or the need for a pericardial drainage procedure during 1 month (OR = 0.148; 95% CI = 0.068-0.318; P effusion and decreases the need for pericardial drainage after heart transplantation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. A generalized Dynamic Overflow Risk Assessment (DORA) for urban drainage RTC

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Grum, Morten

    2012-01-01

    An innovative generalized approach for integrated real time control of urban drainage systems is presented. The Dynamic Overflow Risk Assessment (DORA) strategy tries to minimize the expected overflow risk by considering (i) the water volume presently stored in the drainage network, (ii) the expe......An innovative generalized approach for integrated real time control of urban drainage systems is presented. The Dynamic Overflow Risk Assessment (DORA) strategy tries to minimize the expected overflow risk by considering (i) the water volume presently stored in the drainage network, (ii...... to reduce Combined Sewer Overflow loads and to optimize the flow discharged to the wastewater treatment plant. Also, the inclusion of forecasts and their uncertainty contributed to further improve the performance of drainage systems. The results of this paper will contribute to a wider usage of global RTC...

  19. Tile Drainage Density Reduces Groundwater Travel Times and Compromises Riparian Buffer Effectiveness.

    Science.gov (United States)

    Schilling, Keith E; Wolter, Calvin F; Isenhart, Thomas M; Schultz, Richard C

    2015-11-01

    Strategies to reduce nitrate-nitrogen (nitrate) pollution delivered to streams often seek to increase groundwater residence time to achieve measureable results, yet the effects of tile drainage on residence time have not been well documented. In this study, we used a geographic information system groundwater travel time model to quantify the effects of artificial subsurface drainage on groundwater travel times in the 7443-ha Bear Creek watershed in north-central Iowa. Our objectives were to evaluate how mean groundwater travel times changed with increasing drainage intensity and to assess how tile drainage density reduces groundwater contributions to riparian buffers. Results indicate that mean groundwater travel times are reduced with increasing degrees of tile drainage. Mean groundwater travel times decreased from 5.6 to 1.1 yr, with drainage densities ranging from 0.005 m (7.6 mi) to 0.04 m (62 mi), respectively. Model simulations indicate that mean travel times with tile drainage are more than 150 times faster than those that existed before settlement. With intensive drainage, less than 2% of the groundwater in the basin appears to flow through a perennial stream buffer, thereby reducing the effectiveness of this practice to reduce stream nitrate loads. Hence, strategies, such as reconnecting tile drainage to buffers, are promising because they increase groundwater residence times in tile-drained watersheds. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. Drainage Structure Datasets and Effects on LiDAR-Derived Surface Flow Modeling

    Directory of Open Access Journals (Sweden)

    Ruopu Li

    2013-12-01

    Full Text Available With extraordinary resolution and accuracy, Light Detection and Ranging (LiDAR-derived digital elevation models (DEMs have been increasingly used for watershed analyses and modeling by hydrologists, planners and engineers. Such high-accuracy DEMs have demonstrated their effectiveness in delineating watershed and drainage patterns at fine scales in low-relief terrains. However, these high-resolution datasets are usually only available as topographic DEMs rather than hydrologic DEMs, presenting greater land roughness that can affect natural flow accumulation. Specifically, locations of drainage structures such as road culverts and bridges were simulated as barriers to the passage of drainage. This paper proposed a geospatial method for producing LiDAR-derived hydrologic DEMs, which incorporates data collection of drainage structures (i.e., culverts and bridges, data preprocessing and burning of the drainage structures into DEMs. A case study of GIS-based watershed modeling in South Central Nebraska showed improved simulated surface water derivatives after the drainage structures were burned into the LiDAR-derived topographic DEMs. The paper culminates in a proposal and discussion of establishing a national or statewide drainage structure dataset.

  1. Reuse of drainage water model : calculation method of drainage water and watertable depth

    NARCIS (Netherlands)

    Roest, C.W.J.; Rijtema, P.E.; Abdel Khalik, M.A.

    1986-01-01

    The main objective of the project is to assist the Ministry of Irrigation in Egypt in the planning of future watermanagement strategies incorporating reuse of drainage water practices. In order to achieve this main objective a comprehensive measurement programme has been initiated and a mathematical

  2. Erika: evaluation of residual sanitary risks linked to the beaches-going after cleaning-up; Erika: evaluation des risques sanitaires residuels lies a la frequentation des plages apres depollution

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The aim of this study is to evaluate the sanitary risks for the populations frequenting the coast beaches affected by the fuel oils of the tanker Erika, after their cleaning up. This quantitative evaluation of sanitary risks is led according to a protocol developed jointly between the two institutes ( the national institute of industrial environment and risks, I.N.E.R.I.S., and the national institute of sanitary watch I.n.V.S.). It does not give the risks in function the residual pollution level of concerned beaches but supplies to the authorities elements of scientific information in order to allow them to choose criteria appropriate for the management of eventual residual risks. (N.C.)

  3. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; van Brunschot, Sandra; Bakker, Olaf J.; Ahmed Ali, Usama; van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; van Santvoort, Hjalmar C.

    2016-01-01

    At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. This was a post hoc analysis of 130

  4. Evaluation of new location of Isfahan′s sanitary landfill site with Oleckno method

    OpenAIRE

    Maryam Salimi; Afshin Ebrahimi; Afsane Salimi

    2013-01-01

    Aims: The objective of present study was to evaluate the new location of Isfahan solid waste sanitary landfill using Geographical Information System (GIS) based on the Oleckno index method (OIM). Materials and Methods: This study was on the field- and library-based data collection and surveys of relevant data. Assessment parameters included average annual rainfall, soil type and ground water beneath and adjucent to the landfill site. To analyze data, ArcGIS version 9.3 was used. Resul...

  5. Efficiency of lachrymal sac drainage in newborns with dacryocystocele

    Directory of Open Access Journals (Sweden)

    Sakovich V.N.

    2016-12-01

    Full Text Available The article represents results of treatment of 14 newborns with unilateral dacryocystocele. Patients age was 7.2±0.5 days. In 9 newborns (64.3% dacryocystocele was complicated with lachrymal sac phlegmon; in 5 children (35.7% any complications were absent. Drainage of lachrymal sac through the lower lachrymal canaliculus, instillation of antibiotics, systemic antibiotic therapy in case of phlegmon were performed in all the children. Lachrymal sac washing was performed with a solution of the antibiotic ofloxacin till clear fluid evacuation. If necessary the drainage was repeated in 10 days. The drainage of lachrymal sac was successful in all the patients. 2-3 weeks after the drainage probing of nasolachrymal duct was perfomed in 4 children (28.6% including those 3 with lacrymal sac phlegmon. In 71.4% regression of dacryocystocele occurred itself. Any complications and side effects were not observed. Positive effect of the drainage, according to the authors, can be explained so that dilatation of lachrymal canaliculus before the procedure allows to eliminate Rosenmьller valve stenosis and evacuation of fluid, mucus and pus, being breeding ground for microorganisms from lachrymal sac, promotes inflammation subsiding. Authors also recommend to pay attention on prenatal diagnosis of dacryocystocele, using ultrasound investigation in the 3rd trimester of pregnancy.

  6. Modeling of subglacial hydrological development following rapid supraglacial lake drainage

    OpenAIRE

    Dow, C F; Kulessa, B; Rutt, I C; Tsai, V C; Pimentel, S; Doyle, S H; van As, D; Lindb?ck, K; Pettersson, R; Jones, G A; Hubbard, A

    2015-01-01

    The rapid drainage of supraglacial lakes injects substantial volumes of water to the bed of the Greenland ice sheet over short timescales. The effect of these water pulses on the development of basal hydrological systems is largely unknown. To address this, we develop a lake drainage model incorporating both (1) a subglacial radial flux element driven by elastic hydraulic jacking and (2) downstream drainage through a linked channelized and distributed system. Here we present the model and exa...

  7. Urban drainage models - making uncertainty analysis simple

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Mikkelsen, Peter Steen; Deletic, Ana

    2012-01-01

    in each measured/observed datapoint; an issue which is commonly overlook in the uncertainty analysis of urban drainage models. This comparison allows the user to intuitively estimate the optimum number of simulations required to conduct uncertainty analyses. The output of the method includes parameter......There is increasing awareness about uncertainties in modelling of urban drainage systems and, as such, many new methods for uncertainty analyses have been developed. Despite this, all available methods have limitations which restrict their widespread application among practitioners. Here...

  8. Pressure Jumps during Drainage in Macroporous Soils

    DEFF Research Database (Denmark)

    Soto, Diego; Paradelo Pérez, Marcos; Corral, A

    2018-01-01

    Tensiometer readings obtained at high resolution during drainage of structured soil columns revealed pressure jumps with long range correlations and burst sequences with a hierarchical structure. The statistical properties of jumps are similar to Haines jumps described in invasion percolation...... processes at pore scale, but they are much larger in amplitude and duration. Pressure jumps can result from transient redistribution of water potential in internal regions of soil and can be triggered during drainage by capillary displacements at the scale of structural pores....

  9. Treatment of posthemorrhagic hydrocephalus in premature infants with subcutaneous reservoir drainage.

    Science.gov (United States)

    Yu, Bo; Li, Shasha; Lin, Zhenlang; Zhang, Nu

    2009-01-01

    To investigate the effectiveness of subcutaneous reservoir drainage as a treatment for the different types of posthemorrhagic hydrocephalus in premature infants. 11 premature infants with posthemorrhagic hydrocephalus underwent subcutaneous reservoir embedment surgery, and cerebrospinal fluid (CSF) was drained via the reservoir intermittently for 8 weeks. During the period of drainage, ultrasound and computerized tomography were used to measure ventricle size. CSF examinations were performed routinely to assess the presence of intraventricular hemorrhage (IVH) and/or infection. (1) Five infants were diagnosed as having obstructive hydrocephalus; 2 had nearly normal ventricle sizes with treatment and drainage was stopped after 8 weeks, 2 had nearly normal ventricle sizes after 4 more weeks of drainage, and 1 underwent ventriculoperitoneal shunt (V-P shunt) surgery due to failure of ventricle size reduction. (2) Six infants were diagnosed as having communicating hydrocephalus; 4 had further enlarged ventricle size after 8 weeks and underwent V-P shunt surgery, 1 had treatment aborted at week 8 of drainage, and only 1 had moderate reduction of ventricle size after 8 weeks. (3) None of the 11 infants had progressive IVH and/or intracranial infection during drainage. Subcutaneous reservoir drainage is a suitable and safe treatment for posthemorrhagic hydrocephalus in premature infants. It is more effective for obstructive hydrocephalus than for communicating hydrocephalus. Copyright (c) 2009 S. Karger AG, Basel.

  10. 13 Morphometric Analysis of Ogunpa and Ogbere Drainage Basins ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    significance of these landscape parameters was ... reported that the geomorphic characteristics of a drainage basins play ... form and process of drainage basins that may ... tropical rain forest of Nigeria occupying an area of .... morphometric parameters such as relief, shape ... on floodplains can be pulled down while areas.

  11. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  12. DETERMINATION OF EFFICIENCY OF THE CIRCUMFERENTIAL DRAINAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Maciej Kroll

    2015-11-01

    Full Text Available One of the potential alternatives to improve the stability coefficient for an embankment structure is to flatten the filtration curve. As a result, we obtain lower body forces triggering the potential landslide and more advantageous soil strength parameters, which counteract landslide movements. In the case of waste dumps lowering the phreatic surface of waters is achieved thanks to the construction of auxiliary drainage systems, meeting the guidelines for their safe operation. The aim of this paper is to indicate a method facilitating the determination of the actual position of the phreatic surface within the deposited sediments and the assessment of efficiency of the circumferential drainage system in the waste dump. It was decided in this study to apply cone penetration test CPTU. The CPTU made it possible to measure dissipation of excess water pressure in pores identifying drainage conditions, which were compared with the results of piezometric measurements. The results of these tests made it possible to monitor changes in the position of the depression curve of supernatant waters in dams and to determine the efficiency of the circumferential drainage system.

  13. Investigations of lymphatic drainage from the interstitial space

    Science.gov (United States)

    Jayathungage Don, Tharanga; Richard Clarke Collaboration; John Cater Collaboration; Vinod Suresh Collaboration

    2017-11-01

    The lymphatic system is a highly complex biological system that facilitates the drainage of excess fluid in body tissues. In addition, it is an integral part of the immunological control system. Understanding the mechanisms of fluid absorption from the interstitial space and flow through the initial lymphatics is important to treat several pathological conditions. The main focus of this study is to computationally model the lymphatic drainage from the interstitial space. The model has been developed to consider a 3D lymphatic network and uses biological data to inform the creation of realistic geometries for the lymphatic capillary networks. We approximate the interstitial space as a porous region and the lymphatic vessel walls as permeable surfaces. The dynamics of the flow is approximated by Darcy's law in the interstitium and the Navier-Stokes equations in the lymphatic capillary lumen. The proposed model examines lymph drainage as a function of pressure gradient. In addition, we have examined the effects of interstitial and lymphatic wall permeabilities on the lymph drainage and the solute transportation in the model. The computational results are in accordance with the available experimental measurements.

  14. Do sanitary ceramic workers have a worse presentation of chest radiographs or pulmonary function tests than other ceramic workers?

    Directory of Open Access Journals (Sweden)

    Yu-Chung Tsao

    2017-03-01

    Conclusion: In this study, we found that sanitary ceramic workers were at a similar risk to other ceramic workers for moderate to severe silicosis when older age and longer working duration were accounted for.

  15. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  16. Non-drainage scleral buckling with solid silicone elements

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2014-01-01

    Full Text Available Background: With the increasing number of cataract surgeries, incidence of posterior segment complications including rhegmatogenous retinal detachment (RRD is likely to rise. Scleral buckling (SB surgery is an effective and less expensive option. The primary advantage of non-drainage procedure is avoidance of possible complications associated with trans-choroidal drainage. The aim of present study is to describe the clinical profile of subjects undergoing non-drainage SB surgery with solid silicone elements for RRD and analyze their treatment outcomes. Materials and Methods: This was a retrospective, non-randomized, interventional study at a tertiary care center. Three hundred and six eyes of 298 patients undergoing non-drainage SB surgery with solid silicone elements from year 2000 to 2006 were included. Inclusion criteria were primary RRD, peripheral depressible retinal break, media clarity affording peripheral retinal view and proliferative vitreo-retinopathy (PVR up to grade C2. Uni- and multivariate analyses was done to analyze factors affecting anatomical and visual outcomes. Statistical analysis was performed using SPSS Version 10. Results: Mean follow-up was 303 ± 393.33 days. Primary anatomical success was obtained in 279 (91.2% eyes; primary functional success in 286 (93.5% eyes. PVR (grade B or C, intraocular pressure <10 mm Hg and the inability to find a retinal break were significantly associated with final anatomical failure. Baseline vision ≤3/60 was significantly associated with poor visual recovery. Conclusions: SB surgery is reasonably safe and highly efficacious. Solid silicone elements are effective in non-drainage SB surgery. However, case selection is important.

  17. Remediation of Acid Mine Drainage with Sulfate Reducing Bacteria

    Science.gov (United States)

    Hauri, James F.; Schaider, Laurel A.

    2009-01-01

    Sulfate reducing bacteria have been shown to be effective at treating acid mine drainage through sulfide production and subsequent precipitation of metal sulfides. In this laboratory experiment for undergraduate environmental chemistry courses, students design and implement a set of bioreactors to remediate acid mine drainage and explain observed…

  18. [Sanitary control of alcohol advertisement in Brazil: a study of the law bills from 1988 to 2004].

    Science.gov (United States)

    Falcão, Isa Cristina Lopes; Rangel-S, Maria Ligia

    2010-11-01

    This study analyses law bills towards the sanitary control of alcohol advertisement in the mass media presented to the Brazilian Congress from 1988 to 2004. The sanitary control of this advertising is a controversial issue bringing about an ethical-political debate in which the health-protecting interests conflict with commercial ones even after scientific evidence has established increasing alcohol intake as a health and social issue worldwide. The content analysis of 67 of such law bills was carried out, and these proposals were shown to consist mostly of strategies to both cope with alcohol advertising by dissociating from the product those values that might interfere with the children and teenagers' building of their social identity and limit advertisement contents in the mass media given the higher vulnerability of the subjects in that age range. This study reveals complexes challenges for the control of alcohol advertisement that in turn lead to rethinking the action of the State apparatus in dealing with this major public health issue.

  19. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages.

    Science.gov (United States)

    Carvalho Filho, Elio Barreto de; Marson, Fernando Augusto de Lima; Costa, Loredana Nilkenes Gomes da; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.

  20. SOIL AND “CERRADO” TREES NUTRIENTS AND METALS IN ADJACENT SANITARY LANDFILL AREA

    OpenAIRE

    Otacílio Antunes Santana; José Imanã Encinas; Rodrigo Studart Corrêa; Antônio Felipe Couto Júnior

    2008-01-01

    This research verified the influence of a Sanitary Landfill located at the Jockey Club of the Brasilia City (JCB) on the chemical contents in the tree species of “Cerrado”. Six 25 x 500 m blocks were established in the PNB to sample the soil and the trees to chemical analysis. Three blocks were established near the landfill area and three in the control area. Nitrogen, phosphorus, potassium, calcium, lead, chromium, copper and mercury were analyzed. The highest nutrients and metals concentrat...

  1. Sanitary landfill leachate as a source of nutrients on the initial growth of sunflower plants

    Directory of Open Access Journals (Sweden)

    Francisco H. Nunes Júnior

    Full Text Available ABSTRACT The aim of this study was to evaluate the initial growth of sunflower seedlings under different concentrations of sanitary landfill leachate, considering the feasibility of its use as source of nutrients for agricultural production. Biometric and vigor variables were analyzed through the measurements of collar diameter, shoot height, number of leaves and shoot and root fresh and dry matters, from January to February 2015. The experimental design was completely randomized in a 5 x 4 factorial scheme: five leachate concentrations (0, 40, 60, 80 and 100 kg N ha-1 x four harvest periods (14, 21, 25 and 29 days after sowing, with five replicates each containing two plants. The data were subjected to analysis of variance and polynomial regression, and the results of the last harvest (29 DAS were compared by Tukey test (p ≤ 0.05. The use of sanitary landfill leachate increased all analyzed variables in sunflower plants when compared to the control plants (without leachate, especially in the treatment of 100 kg N ha-1. There was no inhibitory effect of the leachate on the initial growth of sunflower seedlings under adopted experimental conditions.

  2. 77 FR 65760 - Request for Public Comments To Compile the Reports on Sanitary and Phytosanitary and Technical...

    Science.gov (United States)

    2012-10-30

    ... Technical Barriers to Trade (2012 TBT Report) respectively. The TPSC invites written comments from the public on issues that USTR should examine in preparing the SPS and TBT Reports. DATES: Public comments..., Director of Sanitary and Phytosanitary Affairs, USTR (202-395-6127). Questions regarding the TBT Report or...

  3. Evaluation of Critical Parameters to Improve Slope Drainage System

    Directory of Open Access Journals (Sweden)

    Yong Weng Long

    2017-01-01

    Full Text Available This study focuses on identifying and evaluating critical parameters of various drainage configurations, arrangement, and filter which affect the efficiency of water draining system in slopes. There are a total of seven experiments with different types of homogeneous soil, drainage envelope, filter material, and quantity of pipes performed utilizing a model box with a dimension of 0.8 m × 0.8 m × 0.6 m. The pipes were orientated at 5 degrees from the horizontal. Rainfall event was introduced via a rainfall simulator with rainfall intensity of 434.1 mm/h. From the experiments performed, the expected outcomes when utilizing double pipes and geotextile as envelope filter were verified in this study. The results obtained from these experiments were reviewed and compared with Chapter 14 “Subsurface Drainage Systems” of DID’s Irrigation and Agricultural Drainage Manual of Malaysia and the European standard. It is recommended that the pipe installed in the slope could be wrapped with geotextile and in tandem with application of granular filter to minimize clogging without affecting the water discharge rate. Terzaghi’s filter criteria could be followed closely when deciding on new materials to act as aggregate filter. A caging system could be introduced as it could maintain the integrity of the drainage system and could ease installation.

  4. Fluid collection after partial pancreatectomy: EUS drainage and long-term follow-up.

    Science.gov (United States)

    Caillol, Fabrice; Godat, Sebastien; Turrini, Olivier; Zemmour, Christophe; Bories, Erwan; Pesenti, Christian; Ratone, Jean Phillippe; Ewald, Jacques; Delpero, Jean Robert; Giovannini, Marc

    2018-03-29

    Postoperative fluid collection due to pancreatic leak is the most frequent complication after pancreatic surgery. Endoscopic ultrasound (EUS)-guided drainage of post-pancreatic surgery fluid collection is the gold standard procedure; however, data on outcomes of this procedure are limited. The primary endpoint of our study was relapse over longterm followup, and the secondary endpoint was the efficiency and safety of EUS-guided drainage of post-pancreatic surgery fluid collection. This retrospective study was conducted at a single center from December 2008 to April 2016. Global morbidity was defined as the occurrence of an event involving additional endoscopic procedures, hospitalization, or interventional radiologic or surgical procedures. EUS-guided drainage was considered a clinical failure if surgery was required to treat a relapse after stent removal. Fortyone patients were included. The technical success rate was 100%. Drainage was considered a clinical success in 93% (39/41) of cases. Additionally, 19 (46%) complications were identified as global morbidity. The duration between surgery and EUS-guided drainage was not a significantly related factor for morbidity rate (P = 0.8); however, bleeding due to arterial injuries (splenic artery and gastroduodenal artery) from salvage drainage procedures occurred within 25 days following the initial surgery. There was no difference in survival between patients with and without complications. No relapse was reported during the followup (median: 44.75 months; range: 29.24 to 65.74 months). EUSguided drainage for post-pancreatic surgery fluid collection was efficient with no relapse during longterm followup. Morbidity rate was independent of the duration between the initial surgery and EUS-guided drainage; however, bleeding risk was likely more important in cases of early drainage.

  5. Is peritoneal drainage essential after pancreatic surgery?: A meta-analysis and systematic review.

    Science.gov (United States)

    Huan, Lu; Fei, Qilin; Lin, Huapeng; Wan, Lun; Li, Yue

    2017-12-01

    Our objective is to assess the function of peritoneal drainage, which is placed after pancreatic surgery. With the medical advancement some study put forward that peritoneal drainage is not the necessary after pancreatic surgery; it cannot improve the complications of postoperation even leading to more infection and so on. However, there is no one study can clear and definite whether omitting the drainage after surgery or not. Searching databases consist of all kinds of searching tools, such as Medline, The Cochrane Library, Embase, PubMed, etc. All the included studies should meet our demand of this meta-analysis. In the all interest outcomes blow we take the full advantage of RevMan5 to assess, the main measure is odds ratio (OR) with 95% confidence, the publication bias are assessed by Egger test and Begg test. The rate of postoperative pancreatic fistula (POPF) in no drainage group is much lower than that in routine drainage group (OR = 0.47, I = 43%, P drainage can increase the morbidity (OR = 0.71, I = 15%, P = .0002) after pancreaticoduodenectomy (PD), but reduce the mortality (OR = 1.92, I = 8%, P = .03) after PD. In distal pancreatectomy (DP) the rate of POPF and clinically relevant pancreatic fistula (CR-PF) is lower without drainage; there is no significant difference in the CR-PF, hospital stay, intra-abdominal abscess, radiologic invention, and the reoperation. In the current meta-analysis, we cannot make a clear conclusion whether to abandon the routine drainage or not, but from the subgroup we can see something is safer than nothing to routine peritoneal drainage. And the patients who underwent DP can attempt to omit the drainage. But it still needs more RCTs to assess the necessity of drainage. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  6. Controls on deep drainage beneath the root soil zone in snowmelt-dominated environments

    Science.gov (United States)

    Hammond, J. C.; Harpold, A. A.; Kampf, S. K.

    2017-12-01

    Snowmelt is the dominant source of streamflow generation and groundwater recharge in many high elevation and high latitude locations, yet we still lack a detailed understanding of how snowmelt is partitioned between the soil, deep drainage, and streamflow under a variety of soil, climate, and snow conditions. Here we use Hydrus 1-D simulations with historical inputs from five SNOTEL snow monitoring sites in each of three regions, Cascades, Sierra, and Southern Rockies, to investigate how inter-annual variability on water input rate and duration affects soil saturation and deep drainage. Each input scenario was run with three different soil profiles of varying hydraulic conductivity, soil texture, and bulk density. We also created artificial snowmelt scenarios to test how snowmelt intermittence affects deep drainage. Results indicate that precipitation is the strongest predictor (R2 = 0.83) of deep drainage below the root zone, with weaker relationships observed between deep drainage and snow persistence, peak snow water equivalent, and melt rate. The ratio of deep drainage to precipitation shows a stronger positive relationship to melt rate suggesting that a greater fraction of input becomes deep drainage at higher melt rates. For a given amount of precipitation, rapid, concentrated snowmelt may create greater deep drainage below the root zone than slower, intermittent melt. Deep drainage requires saturation below the root zone, so saturated hydraulic conductivity serves as a primary control on deep drainage magnitude. Deep drainage response to climate is mostly independent of soil texture because of its reliance on saturated conditions. Mean water year saturations of deep soil layers can predict deep drainage and may be a useful way to compare sites in soils with soil hydraulic porosities. The unit depth of surface runoff often is often greater than deep drainage at daily and annual timescales, as snowmelt exceeds infiltration capacity in near-surface soil layers

  7. Possible origin and significance of extension-parallel drainages in Arizona's metamophic core complexes

    Science.gov (United States)

    Spencer, J.E.

    2000-01-01

    The corrugated form of the Harcuvar, South Mountains, and Catalina metamorphic core complexes in Arizona reflects the shape of the middle Tertiary extensional detachment fault that projects over each complex. Corrugation axes are approximately parallel to the fault-displacement direction and to the footwall mylonitic lineation. The core complexes are locally incised by enigmatic, linear drainages that parallel corrugation axes and the inferred extension direction and are especially conspicuous on the crests of antiformal corrugations. These drainages have been attributed to erosional incision on a freshly denuded, planar, inclined fault ramp followed by folding that elevated and preserved some drainages on the crests of rising antiforms. According to this hypothesis, corrugations were produced by folding after subacrial exposure of detachment-fault foot-walls. An alternative hypothesis, proposed here, is as follows. In a setting where preexisting drainages cross an active normal fault, each fault-slip event will cut each drainage into two segments separated by a freshly denuded fault ramp. The upper and lower drainage segments will remain hydraulically linked after each fault-slip event if the drainage in the hanging-wall block is incised, even if the stream is on the flank of an antiformal corrugation and there is a large component of strike-slip fault movement. Maintenance of hydraulic linkage during sequential fault-slip events will guide the lengthening stream down the fault ramp as the ramp is uncovered, and stream incision will form a progressively lengthening, extension-parallel, linear drainage segment. This mechanism for linear drainage genesis is compatible with corrugations as original irregularities of the detachment fault, and does not require folding after early to middle Miocene footwall exhumations. This is desirable because many drainages are incised into nonmylonitic crystalline footwall rocks that were probably not folded under low

  8. Intra-abdominal pressure alterations after large pancreatic pseudocyst transcutaneous drainage

    Directory of Open Access Journals (Sweden)

    Papavramidis Theodossis S

    2009-06-01

    Full Text Available Abstract Background Acute pancreatitis leads to abdominal hypertension and compartment syndrome. Weeks after the episodes pancreatic fluids sometimes organize to pseudocysts, fluid collections by or in the gland. Aims of the present study were to evaluate the intra-abdominal pressure (IAP induced by large pancreatic pseudocysts and to examine the effect of their transcutaneous drainage on IAP. Methods Twenty seven patients with a pancreatic pseudocyst were included. Nine patients with pseudocysts greater than 1l (group A had CT drainage and eighteen (volume less than 1l were the control group. The measurements of group A were taken 6 hours before and every morning after the drainage, while for group B, two measurements were performed, one at the day of the initial CT and one 7 days after. Abdominal compliance (Cabd was calculated. Data were analyzed using student's t-test. Results Baseline IAP for group A was 9.3 mmHg (S.D. 1.7 mmHg, while the first post-drainage day (PDD IAP was 5.1 mmHg (S.D. 0.7 mmHg. The second PDD IAP was 5.6 mmHg (S.D. 0.8 mmHg, the third 6.4 mmH (S.D. 1.2 mmHgg, the fourth 6.9 mmHg (S.D. 1.6 mmHg, the fifth 7.9 mmHg (S.D. 1.5 mmHg, the sixth 8.2 mmHg (S.D. 1.4 mmHg, and the seventh 8.2 mmHg (S.D. 1.5 mmHg. Group B had baseline IAP 8.0 mmHg (S.D. 1.2 mmHg and final 8.2 mmHg (S.D. 1.4 mmHg. Cabd after drainage was 185.6 ml/mmHg (SD 47.5 ml/mmHg. IAP values were reduced between the baseline and all the post-drainage measurements in group A. IAPs seem to stabilize after the 5th post-drainage day. Baseline IAP was higher in group A than in group B, while the two values, at day 7, were equivalent. Conclusion The drainage of large pancreatic pseudocyst reduces IAP. Moreover, the IAP seems to rise shortly after the drainage again, but in a way that it remains inferior to the initial value. More chronic changes to the IAP are related to abdominal cavity's properties and have to be further studied.

  9. Percutaneous drainage with ultrasound guidance in the intensive care unit

    International Nuclear Information System (INIS)

    Kang, Doo Kyung; Won, Je Hwan; Kim, Jai Keun; Lee, Kwang Hun; Kim, Ji Hyung

    2004-01-01

    To determine the efficacy and safety of bedside percutaneous drainage procedures with ultrasound guidance in critically ill patients in the intensive care unit (ICU). Sixty five percutaneous drainage procedures performed at the bedside, in 39 ICU patients, were evaluated. All of the procedures were performed with ultrasound guidance alone. The procedures consisted of percutaneous drainage of abdominal (n=35) and pleural (n=27) fluids, percutaneous cholecystostomy (n=2) and percutaneous nephrostomy (n=1). The clinical responses were classified as 'complete response', 'partial response', 'failure' or 'undetermined'. The medical records were reviewed retrospectively to evaluate the clinical response. Technical success was achieved in 64 of the 65 procedures (98.5%). The complication rate was 13.8% (9 cases). There was no immediate procedure-related death or worsening of the clinical condition of the patients. The clinical responses after drainage were 'complete response' in 39 cases (60.9%). 'partial response' in 14 (21.9%), 'failure' in 3 (4.7%), and 'undetermined' in 8 (12.5%). Bedside drainage procedures with ultrasound guidance are effective and safe to perform when patients are too critically ill to be moved from the ICU to the angiography room

  10. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    International Nuclear Information System (INIS)

    Algin, Oktay; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-01-01

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improved clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.

  11. Phyto sanitary Treatment at SINAGAMA: Experience Sharing and Challenge

    International Nuclear Information System (INIS)

    Sofian Ibrahim; Jamilah Karim; Mohd Sidek Othman; Ahsanulkhaliqin Abdul Wahab; Ahmad Zainuri Mohd Dzomir; Zainon Othman; Hasan Sham; Mohd Khairul Azfar Ramli

    2012-01-01

    After more than 22 years involved in sterilization and decontamination of products like medical devices, foods and herbs, Sinagama with the cooperation of SSDL, BAB, MARDI and Malaysia Department of Agriculture has make another step ahead by helping the local fruits farmers on phyto sanitary treatment in order to help them exporting their crops to United States. This report was prepared to discuss the challenges that have been faced by Sinagama during registration and certification process from United States Department of Agriculture (USDA). The challenges that Sinagama have to faced include Minimum Irradiation Dose, Dose Mapping Process, Biological Control, Training Records, Working Procedures and requirements that needed by Plant Health Inspection Service (APHIS) Officer. All these challenged has been faced by Sinagama in order to make sure the ambition of our nation to help farming sector become reality. (author)

  12. Development of subsurface drainage database system for use in environmental management issues

    International Nuclear Information System (INIS)

    Azhar, A.H.; Rafiq, M.; Alam, M.M.

    2007-01-01

    A simple user-friendly menue-driven system for database management pertinent to the Impact of Subsurface Drainage Systems on Land and Water Conditions (ISIAW) has been developed for use in environment-management issues of the drainage areas. This database has been developed by integrating four soft wares, viz; Microsoft Excel, MS Word Acrobat and MS Access. The information, in the form of tables and figures, with respect to various drainage projects has been presented in MS Word files. The major data-sets of various subsurface drainage projects included in the ISLaW database are: i) technical aspects, ii) groundwater and soil-salinity aspects, iii) socio-technical aspects, iv) agro-economic aspects, and v) operation and maintenance aspects. The various ISlAW file can be accessed just by clicking at the Menu buttons of the database system. This database not only gives feed back on the functioning of different subsurface drainage projects, with respect to the above-mentioned aspects, but also serves as a resource-document for these data for future studies on other drainage projects. The developed database-system is useful for planners, designers and Farmers Organisations for improved operation of existing drainage projects as well as development of future ones. (author)

  13. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  14. Evolution of Godoy & Godoy manual lymph drainage. Technique with linear movements

    Directory of Open Access Journals (Sweden)

    José Maria Pereira de Godoy

    2017-10-01

    Full Text Available Manual lymph drainage has become the mainstay in the treatment of lymphedema for decades now. Five evolving variants have been described by Godoy & Godoy over the years: i manual lymph drainage using rollers; ii self-applied manual lymph drainage using rollers; iii manual lymph drainage using the hands (manual lymphatic therapy; iv mechanical lymphatic therapy using the RAGodoy® device; and v lymphatic therapy using cervical stimulation in general lymphatic treatment. After breast cancer treatment using adapted technique with intermittent compression therapy. Lymphoscintigraphy, volumetry and bioimpedance were employed to analyze such treatment techniques applied to the upper and lower extremities. These treatment and evaluation topics are described in this brief report.

  15. Implementation of a drainage information, analysis and management system

    Directory of Open Access Journals (Sweden)

    J.N. Meegoda

    2017-04-01

    Full Text Available An integrated drainage information, analysis and management system (DIAMS was developed and implemented for the New Jersey Department of Transportation (NJDOT. The purpose of the DIAMS is to provide a useful tool for managers to evaluate drainage infrastructure, to facilitate the determination of the present costs of preserving those infrastructures, and to make decisions regarding the optimal use of their infrastructure budgets. The impetus for DIAMS is the culvert information management system (CIMS, which is developed to manage the data for culvert pipes. DIAMS maintains and summarizes accumulated inspection data for all types of drainage infrastructure assets, including pipes, inlet/outlet structures, outfalls and manufactured treatment devices. DIAMS capabilities include identifying drainage infrastructure, maintaining inspection history, mapping locations, predicting service life based on the current condition states, and assessing present asset value. It also includes unit cost values of 72 standard items to estimate the current cost for new assets with the ability to adjust for future inflation. In addition, DIAMS contains several different repair, rehabilitation and replacement options to remedy the drainage infrastructure. DIAMS can analyze asset information and determine decisions to inspect, rehabilitate, replace or do nothing at the project and network levels by comparing costs with risks and failures. Costs may be optimized to meet annual maintenance budget allocations by prioritizing drainage infrastructure needing inspection, cleaning and repair. DIAMS functional modules include vendor data uploading, asset identification, system administration and financial analysis. Among the significant performance feature of DIAMS is its proactive nature, which affords decision makers the means of conducting a comprehensive financial analysis to determine the optimal proactive schedule for the proper maintenance actions and to prioritize them

  16. Effects of peatland drainage management on peak flows

    Directory of Open Access Journals (Sweden)

    C. E. Ballard

    2012-07-01

    Full Text Available Open ditch drainage has historically been a common land management practice in upland blanket peats, particularly in the UK. However, peatland drainage is now generally considered to have adverse effects on the upland environment, including increased peak flows. As a result, drain blocking has become a common management strategy in the UK over recent years, although there is only anecdotal evidence to suggest that this might decrease peak flows. The change in the hydrological regime associated with the drainage of blanket peat and the subsequent blocking of drains is poorly understood, therefore a new physics-based model has been developed that allows the exploration of the associated hydrological processes. A series of simulations is used to explore the response of intact, drained and blocked drain sites at field scales. While drainage is generally found to increase peak flows, the effect of drain blocking appears to be dependent on local conditions, sometimes decreasing and sometimes increasing peak flows. Based on insights from these simulations we identify steep smooth drains as those that would experience the greatest reduction in field-scale peak flows if blocked and recommend that future targeted field studies should be focused on examining surface runoff characteristics.

  17. [Should surgeons keep performing drainage after breast reduction?

    Science.gov (United States)

    Vidali, N; Chevet-Noel, A; Ringenbach, P; Andreoletti, J B

    2018-04-09

    Despite the absence of "evidence-based medicine", the use of closed suction drainage in breast surgery is currently the standard practice. Its goal is to minimize the amount of fluid at the operation site, the dead space that can involve postoperative complications. The purpose of this study is to demonstrate that with or without drainage the complication rate is unchanged. We conducted a retrospective and comparative study of two groups of breast reduction with and without drainage. Every complication has been recorded and statistically analyzed: seroma and hematoma, infections, wound breakdown, skin flap or nipple-areola complex necrosis, fat necrosis and reoperation. A total of 138 breast reductions were performed (37 drained patients and 32 non-drained). Data collection of complications was done on average 10months after the operation (1-15). There was no statistical difference between the two groups regarding the complication rate. Our results confirm the ones found in the literature. Except for specific cases (e.g. gigantomasty), this study demonstrates that after breast reduction, drainage is not appropriate. Drains do not reduce postoperative complications and can increase hospitalization length of stay (inducing higher costs). Furthermore, it is often source of pain, anxiety and discomfort for patients. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  18. 75 FR 36288 - Amended Safety Zone and Regulated Navigation Area, Chicago Sanitary and Ship Canal, Romeoville, IL

    Science.gov (United States)

    2010-06-25

    ...The Coast Guard is revising its safety zone and Regulated Navigation Area (RNA) on the Chicago Sanitary and Ship Canal (CSSC) near Romeoville, IL. This revised temporary interim rule reduces the areas covered by the safety zone and RNA, and places additional restrictions on vessels that may transit the RNA.

  19. Percutaneous catheter drainage of empyema and loculated pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Im, Jung Gi; Park, Kyung Joo; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1988-08-15

    Closed thoracotomy by using a chest tube in cases of thoracic empyema is known to be an effective and popular way of treatment. However, it happens commonly that chest tube drainage is not appropriate because of either malpositioning of the tube or undesirable patient's general condition such as bleeding tendency or debilitation. We performed fluoroscopy-guided percutaneous catheter drainage (PCD) in 14 cases of empyema and loculated pleural effusion and in 2 cases of lung abscess. In most of the patients, PCDs were performed because chest tube drainage was considered to be inappropriate or after failed chest tube drainage. In all patients, catheters were successfully placed into the fluid collections, which were drained effectively. Ten of the 11 febrile patient showed improvement of feverishness within 24 hours after PCD. 10 patients were cured without further treatment. Complications were few and minimal. We believe that the safety, effectiveness and good patients tolerance of PCD makes it an excellent alternative method of treatment in cases of empyema and loculated pleural effusion.

  20. Groundwater pollution by nitrates in irrigated areas with drainage

    International Nuclear Information System (INIS)

    Chandio, B.M.; Azam, M.; Abdullah, M.

    2001-01-01

    Field studies were conducted at three selected sites in irrigated areas of Pakistan to assess magnitude and severity of groundwater pollution by nitrates. The results of these studies indicate that concentration of nitrates in most of the samples collected from irrigated areas having drainage facility is much lower than threshold limit. The nitrate-nitrogen level within drainage projects ranges from 0.01-9.00 mg/l and in the area without drainage system ranges from 10.1-12.5 mg/l. The mineral fertilizers though are making contribution of NO3-N to the groundwater sources but that is much lower than threshold limits. The presence of septic tanks or farmyard manure dumps is also significant contributors of NO3-N to the groundwater. Thus drinking water sources near these polluting points are probable danger to human health. It is, therefore, concluded that still there is a lot of potential for fertilizer use in the agriculture but proper drainage facilities should be provided to minimize the potential threat of NO/sub 3/ pollution. (author)

  1. Gravity Drainage of Activated Sludge on Reed Beds

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Dominiak, Dominik Marek; Keiding, Kristian

    and operation of reed beds and the efficiencies are often lower than predicted. One reason is that the sludge quality varies from plant to plant and even within plants from time to time. No good method exists for measuring the sludge quality with respect to drainage characteristics. A new experimental method...... has therefore been developed to measure relevant quality parameters: specific cake resistance, settling velocity and cake compressibility. It has been found that activated sludge form highly compressible cake even at the low compressive pressures obtained during drainage. Numerical simulation shows......Activated sludge is a by-product from waste water treatment plants, and the water content in the sludge is high (> 90%). Among several methods to remove the water, sludge drying reed beds are often used to dewater the sludge by drainage. There is, however, no well-defined criterion for design...

  2. Assessment of drainage techniques for evacuation of chronic subdural hematoma

    DEFF Research Database (Denmark)

    Sjåvik, Kristin; Bartek, Jiri; Sagberg, Lisa Millgård

    2018-01-01

    OBJECTIVE Surgery for chronic subdural hematoma (CSDH) is one of the most common neurosurgical procedures. The benefit of postoperative passive subdural drainage compared with no drains has been established, but other drainage techniques are common, and their effectiveness compared with passive...

  3. Transanal Drainage of Coloanal Anastomotic Leaks

    Directory of Open Access Journals (Sweden)

    Bradley Sherman

    2018-01-01

    Full Text Available The conventional operative intervention for leaks following coloanal anastomoses has been proximal fecal diversion with or without take-down of anastomosis. A few of these cases are also amenable to percutaneous drainage. Ostomies created in this situation are often permanent, specifically in cases where coloanal anastomoses are taken down at the time of reoperation. We present two patients who developed perianastomotic pelvic abscesses that were treated with transanal large bore catheter drainage resulting in successful salvage of coloanal anastomoses without the need for a laparotomy or ostomy creation. We propose this to be an effective therapeutic approach to leaks involving low coloanal anastomoses in the absence of generalized peritonitis.

  4. Percutaneous drainage of 100 subphrenic abscesses

    International Nuclear Information System (INIS)

    Casola, G.; Sonnenberg, E. van; D'Agostino, H.; Kothari, R.; May, S.; Taggart, S.

    1990-01-01

    PURPOSE: Percutaneous drainage of subphrenic abscesses is technically more difficult because lung and pleura may be transgressed during catheter insertion. The purpose of this paper is to determine the incidence of thoracic complications secondary to subphrenic abscess drainage and to determine factors that may alter this. The authors' series consists of 100 subphrenic abscesses that were drained percutaneously. Patients range in age from 14 to 75 years. Abscesses were secondary to surgery (splenectomy, pancreatectomy, partial hepatectomy, gastrectomy), pancreatitis, and trauma. Catheters ranged in size from 8 to 14 F and were inserted via trocar or Seldinger technique. Thoracic complications of pneumothorax or empyema were determined from follow-up chest radiographs or CT scans

  5. CT Fluoroscopy-Guided Transsacral Intervertebral Drainage for Pyogenic Spondylodiscitis at the Lumbosacral Junction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Tomohiro, E-mail: t-matsu@tokai-u.jp; Mine, Takahiko, E-mail: mine@tsc.u-tokai.ac.jp; Hayashi, Toshihiko, E-mail: t.hayashi@tokai.ac.jp [Tokai University School of Medicine, Department of Radiology, Tokai University Hachioji Hospital (Japan); Kamono, Masahiro, E-mail: kamono@tsc.u-tokai.ac.jp; Taoda, Akiko, E-mail: acco@is.icc.u-tokai.ac.jp; Higaki, Megumu, E-mail: higaki@hachioji-hosp.tokai.ac.jp [Tokai University School of Medicine, Department of General Internal Medicine, Tokai University Hachioji Hospital (Japan); Hasebe, Terumitsu, E-mail: hasebe@tokai-u.jp [Tokai University School of Medicine, Department of Radiology, Tokai University Hachioji Hospital (Japan)

    2017-01-15

    PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsy needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.

  6. Socially optimal drainage system and agricultural biodiversity: a case study for Finnish landscape.

    Science.gov (United States)

    Saikkonen, Liisa; Herzon, Irina; Ollikainen, Markku; Lankoski, Jussi

    2014-12-15

    This paper examines the socially optimal drainage choice (surface/subsurface) for agricultural crop cultivation in a landscape with different land qualities (fertilities) when private profits and nutrient runoff damages are taken into account. We also study the measurable social costs to increase biodiversity by surface drainage when the locations of the surface-drained areas in a landscape affect the provided biodiversity. We develop a general theoretical model and apply it to empirical data from Finnish agriculture. We find that for low land qualities the measurable social returns are higher to surface drainage than to subsurface drainage, and that the profitability of subsurface drainage increases along with land quality. The measurable social costs to increase biodiversity by surface drainage under low land qualities are negative. For higher land qualities, these costs depend on the land quality and on the biodiversity impacts. Biodiversity conservation plans for agricultural landscapes should focus on supporting surface drainage systems in areas where the measurable social costs to increase biodiversity are negative or lowest. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Early Removal of Drainage Tube after Fast-Track Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Zhang, Shaoyun; Xu, Bin; Huang, Qiang; Yao, Huan; Xie, Jinwei; Pei, Fuxing

    2017-07-01

    There is no consensus as to whether drainage tube should be used and how long it should remain in use after primary total knee arthroplasty (TKA). As fast-track (FT) program has been implemented in TKA, whether drainage tube could be removed early, and the ideal timing for removal after FT primary TKA has been a new topic. The purpose of this prospective cohort study was to evaluate the safety and feasibility of early removal of drainage tube when FT program was implemented in primary TKA. A total of 101 patients undergoing FT primary TKA were prospectively allocated into three groups. Patients in group A (31 patients) indwelled wound drainage tube for 6 hours after surgery while group B (34 patients) for 12 hours and group C (36 patients) for 18 hours. The knee circumference, resting and moving visual analogue score (VAS), hemoglobin (Hb), hematocrit, white blood count (WBC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), interleukin-6 (IL-6), the volume of blood loss and drainage, and postoperative length of stay (LOS) among three groups were recorded and compared. There was no statistically significant difference in the volume of total and hidden blood loss among three groups ( p  > 0.05), but as the time of drainage prolonged, total volume of drainage and dominant blood loss increased gradually ( p   0.05), the decrease of Hb in the perioperative period and postoperative LOS as well. Early removal of wound drainage tube could drain the hematocele and reduce the risk of infection, and it doesn't increase the sense of pain, inflammatory reaction, limb swelling, and total blood loss. It's safe and feasible to remove the drainage tube within 6 to 12 hours after FT primary TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Effects of peatland drainage management on peak flows

    OpenAIRE

    C. E. Ballard; N. McIntyre; H. S. Wheater

    2011-01-01

    Open ditch drainage has historically been a common land management practice in upland blanket peats, particularly in the UK. However, peatland drainage is now generally considered to have adverse effects on the upland environment, including increased peak flows. As a result, drain blocking has become a common management strategy in the UK over recent years, although there is only anecdotal evidence to suggest that this might decrease peak flows. The change in the hydrologica...

  9. Treatment of lung abscess: effectiveness of percutaneous catheter drainage in 14 patients

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Hyun; Han, Young Min; Kim, Chong Soo; Chung, Gyung Ho; Ryu, Chun Su; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University Medical School, Cheonju (Korea, Republic of)

    1995-01-15

    To evaluate the effectiveness of percutaneous catheter drainage in treatment of the lung abscess. We treated the lung abscesses in 14 patients (12 mean, 2 women), who did not respond to medical therapy, by percutaneous catheter drainage under fluoroscopic or ultrasound guidance. One abscess due to infacted bulla was managed by combination treatment with alcohol sclerosing therapy. Patients were followed by serial chest radiographs every three days and the amount of drained or aspirated pus evaluated. The treatment effect and recurrence were followed by chest PA and lateral chest at one week after removal of drainage catheter. Thirteen patients (93%) recovered clinically and radiologically within 3 days. In 10 patients, drainage catheter could be removed within 2 weeks, and three patients, the catheter was kept longer. Most complications were mild; vague to moderate chest pain (n = 14), mild hemoptysis (n = 2), and pneumothorax (n = 1). One man who suffered from far advanced pulmonary tuberculosis died of asphyxia caused by massive hemoptysis 16 days after percutaneous drainage. Percutaneous catheter drainage is a safe and effective method for treating lung abscess.

  10. Mortality Following Catheter Drainage Versus Thoracentesis in Cirrhotic Patients with Pleural Effusion.

    Science.gov (United States)

    Hung, Tsung-Hsing; Tseng, Chih-Wei; Tsai, Chen-Chi; Hsieh, Yu-Hsi; Tseng, Kuo-Chih; Tsai, Chih-Chun

    2017-04-01

    Pleural effusion is an abnormal collection of body fluids that may cause related morbidity or mortality in cirrhotic patients. There are insufficient data to determine the optimal method of drainage, for symptomatic relief in cirrhotic patients with pleural effusion. In this study, we compare the mortality outcomes of catheter drainage versus thoracentesis in cirrhotic patients. The National Health Insurance Database, derived from the Taiwan National Health Insurance Program, was used to identify cirrhotic patients with pleural effusion requiring drainage between January 1, 2007, and December 31, 2010. In all, 2556 cirrhotic patients with pleural effusion were selected for the study and divided into the two groups (n = 1278/group) after propensity score matching. The mean age was 61.0 ± 14.3 years, and 68.9% (1761/2556) were men. The overall 30-day mortality was 21.0% (538/2556) and was higher in patients treated with catheter drainage than those treated with thoracentesis (23.5 vs. 18.6%, respectively, P pleural effusion requiring drainage, catheter drainage is associated with higher mortality compared to thoracentesis.

  11. Treatment Experience of Continuous Negative Pressure Drainage in the Acute Anterior Mediastinal Infection of Oropharyngeal Origined

    Directory of Open Access Journals (Sweden)

    Anping CHEN

    2018-04-01

    Full Text Available Background and objective Mediastinal infection is a serious infection of mediastinal connective tissue, with more complications and higher mortality. Application of broad-spectrum antibiotics and nutritional support, early sufficient drainage is the key to successful treatment. In the mode of drainage, this paper discusses the application of continuous negative pressure drainage technique to treat acute anterior mediastinal infection of severe mouth pharynx source, and the good results are summarized and shared. Methods In January to December in 2017, a total of 17 cases treated acute mediastinal infection is derived from the throat, has formed a mediastinal abscess, surgery adopts retrosternal counterpart negative pressure drainage way, namely the sternum nest and free sternum xiphoid process under the incision on the first mediastinal clearance, make breakthrough and placed drainage device, suture closed wound, continuous negative pressure drainage, negative pressure using 3 cm-5 cm water column. Results Among the 17 patients, 14 patients were relieved by continuous negative pressure drainage, and then the drainage tube was removed. In 2 cases, the infection broke into the right thoracic cavity, and the closed drainage caused the negative pressure to disappear, and the negative pressure drainage was replaced by the conventional drainage, and the drainage tube was removed after the drainage tube was clear. One patient had formed a mediastinal abscess incision drainage time later, complicated with septic shock and sepsis, resulting in the death of multiple organ failure. Conclusion The traditional treatment of severe acute mediastinal infection is sternal incision and drainage. Continuous negative pressure drainage adequate drainage of mediastinal can relieve patients' pain, effusion, and avoid the dressing out repeatedly. It is an effective method. However, there are limitations in this method, which need to be further optimized.

  12. Open Drainage and Detention Basin Combined System Optimization

    Directory of Open Access Journals (Sweden)

    M. E. Banihabib

    2017-01-01

    Full Text Available Introduction: Since flooding causes death and economic damages, then it is important and is one of the most complex and destructive natural disaster that endangers human lives and properties compared to any other natural disasters. This natural disaster almost hit most of countries and each country depending on its policy deals with it differently. Uneven intensity and temporal distribution of rainfall in various parts of Iran (which has arid and semiarid climate causes flash floods and leads to too much economic damages. Detention basins can be used as one of the measures of flood control and it detains, delays and postpones the flood flow. It controls floods and affects the flood directly and rapidly by temporarily storing of water. If the land topography allows the possibility of making detention basin with an appropriate volume and quarries are near to the projects for construction of detention dam, it can be used, because of its faster effect comparing to the other watershed management measures. The open drains can be used alone or in combination with detention basin instead of detention basin solitarily. Since in the combined system of open and detention basin the dam height is increasing in contrast with increasing the open drainage capacity, optimization of the system is essential. Hence, the investigation of the sensitivity of optimized combined system (open drainage and detention basin to the effective factors is also useful in appropriately design of the combined system. Materials and Methods: This research aims to develop optimization model for a combined system of open drainage and detention basins in a mountainous area and analyze the sensitivity of optimized dimensions to the hydrological factors. To select the dam sites for detention basins, watershed map with scale of 1: 25000 is used. In AutoCAD environment, the location of the dam sites are assessed to find the proper site which contains enough storage volume of the detention

  13. Drainage filters and constructed wetlands to mitigate site-specific nutrient losses

    DEFF Research Database (Denmark)

    Kjærgaard, Charlotte; Hoffmann, Carl Christian; Iversen, Bo Vangsø

    Despite substantial efforts, the leaching of nutrients from agricultural land is still a serious and costly environmental problem in Denmark and elsewhere. The quality goals of the European Water Framework Directive (WFD) for the aquatic environment require a substantial reduction of diffuse nutr...... drainage. The project studies different approaches of implementing the filter technologies including drainage well or drainage pipe filters as well as surface-flow and sub-surface flow constructed wetlands....

  14. Prevalence of dependent loops in urinary drainage systems in hospitalized patients.

    Science.gov (United States)

    Danek, Gale; Gravenstein, Nikolaus; Lizdas, David E; Lampotang, Samsun

    2015-01-01

    The purpose of this study was to measure the prevalence and configuration of dependent loops in urinary drainage systems in hospitalized, catheterized adults. The study sample comprised 141 patients with indwelling urinary catheters; subjects were hospitalized at an academic health center in northern Florida. We measured the prevalence of dependent loops in urine drainage systems and the incidence of urine-filled dependent loops over a 3-week period. We measured the heights of the crest (H(c)), trough (H(t)), and, when urine-filled dependent loops were present, the patient-side (H(p)) and bag-side (H(b)) menisci with a laser measurement system. All variables were measured in centimeters. The majority of observed urine drainage systems (85%) contained dependent loops in the drainage tubing and 93.8% of the dependent loops contained urine. H(c) and H(t) averaged 45.1 ± 11.1 and 27 ± 16.7 cm, respectively. Meniscus height difference (H(b) - H(p)) averaged 8.2 ± 5.8 and -12.2 ± 9.9 cm when H(p) H(b) (32.7%), respectively. We found that dependent loops are extremely common in urinary drainage systems among hospitalized patients despite the manufacturer recommendations and nursing and hospital policies. Maintaining the urine drainage tubing free of dependent loops would require incorporation into nursing care priorities and workflow as inadvertent force on the tubing, for example, patient movement or nurse contact can change tubing configuration and allow excess drainage tubing to re-form a dependent loop.

  15. Drainage and Stratification Kinetics of Foam Films

    Science.gov (United States)

    Zhang, Yiran; Sharma, Vivek

    2014-03-01

    Baking bread, brewing cappuccino, pouring beer, washing dishes, shaving, shampooing, whipping eggs and blowing bubbles all involve creation of aqueous foam films. Foam lifetime, drainage kinetics and stability are strongly influenced by surfactant type (ionic vs non-ionic), and added proteins, particles or polymers modify typical responses. The rate at which fluid drains out from a foam film, i.e. drainage kinetics, is determined in the last stages primarily by molecular interactions and capillarity. Interestingly, for certain low molecular weight surfactants, colloids and polyelectrolyte-surfactant mixtures, a layered ordering of molecules, micelles or particles inside the foam films leads to a stepwise thinning phenomena called stratification. Though stratification is observed in many confined systems including foam films containing particles or polyelectrolytes, films containing globular proteins seem not to show this behavior. Using a Scheludko-type cell, we experimentally study the drainage and stratification kinetics of horizontal foam films formed by protein-surfactant mixtures, and carefully determine how the presence of proteins influences the hydrodynamics and thermodynamics of foam films.

  16. Transhiatal Chest Drainage After Hybrid Ivor Lewis Esophagectomy: Proof of Concept Study.

    Science.gov (United States)

    Asti, Emanuele; Sironi, Andrea; Bonitta, Gianluca; Bernardi, Daniele; Bonavina, Luigi

    2018-04-01

    Intercostal pleural drainage is standard practice after transthoracic esophagectomy but has some drawbacks. We hypothesized that a transhiatal pleural drain introduced through the subxyphoid port site incision at laparoscopy can be as effective as the intercostal drainage and may enhance patient recovery. A proof of concept study was designed to assess a new method of pleural drainage in patients undergoing hybrid Ivor Lewis esophagectomy (laparoscopy and right thoracotomy). The main study aims were safety and efficacy of transhiatal pleural drainage with a 15 Fr Blake tube connected to a portable vacuum system. Pre- and postoperative data, mean duration, and total and daily output of drainage were recorded in an electronic database. Postoperative complications were scored according to the Dindo-Clavien classification. Between June 2015 and December 2016, 50 of 63 consecutive patients met the criteria for inclusion in the study. No conversions from the portable vacuum system to underwater seal and suction occurred. There was no mortality. The overall morbidity rate was 40%. Two patients (4%) required reoperation for hemothorax and chylothorax, respectively. Percutaneous catheter drainage for residual pneumothorax was necessary in 2 patients (4%) on postoperative day 2. The mean duration of drainage was 7 days (interquartile range [IQR] = 2), and the total volume of drain output was 1580 mL (IQR = 880). No pleural effusion on chest X-ray was detected at the 3-month follow-up visit. Transhiatal pleural drainage is safe and effective after hybrid Ivor Lewis esophagectomy and could replace the intercostal drain in selected patients.

  17. A skin abscess model for teaching incision and drainage procedures.

    Science.gov (United States)

    Fitch, Michael T; Manthey, David E; McGinnis, Henderson D; Nicks, Bret A; Pariyadath, Manoj

    2008-07-03

    Skin and soft tissue infections are increasingly prevalent clinical problems, and it is important for health care practitioners to be well trained in how to treat skin abscesses. A realistic model of abscess incision and drainage will allow trainees to learn and practice this basic physician procedure. We developed a realistic model of skin abscess formation to demonstrate the technique of incision and drainage for educational purposes. The creation of this model is described in detail in this report. This model has been successfully used to develop and disseminate a multimedia video production for teaching this medical procedure. Clinical faculty and resident physicians find this model to be a realistic method for demonstrating abscess incision and drainage. This manuscript provides a detailed description of our model of abscess incision and drainage for medical education. Clinical educators can incorporate this model into skills labs or demonstrations for teaching this basic procedure.

  18. Single chest tube drainage is superior to double chest tube drainage after lobectomy: a meta-analysis.

    Science.gov (United States)

    Zhou, Dong; Deng, Xu-Feng; Liu, Quan-Xing; Chen, Qian; Min, Jia-Xin; Dai, Ji-Gang

    2016-05-27

    In this meta-analysis, we conducted a pooled analysis of clinical studies comparing the efficacy of single chest tube versus double chest tube after a lobectomy. According to the recommendations of the Cochrane Collaboration, we established a rigorous study protocol. We performed a systematic electronic search of the PubMed, Embase, Cochrane Library and Web of Science databases to identify articles to include in our meta-analysis. A literature search was performed using relevant keywords. A meta-analysis was performed using RevMan© software. Five studies, published between 2003 and 2014, including 630 patients (314 patients with a single chest tube and 316 patients with a double chest tube), met the selection criteria. From the available data, the patients using a single tube demonstrated significantly decreased postoperative pain [weighted mean difference [WMD] -0.60; 95 % confidence intervals [CIs] -0.68-- 0.52; P tube after a pulmonary lobectomy. However, there were no significant differences in postoperative complications [OR 0.91; 95 % CIs 0.57-1.44; P = 0.67] and re-drainage rates [OR 0.81; 95 % CIs 0.42-1.58; P = 0.54]. Our results showed that a single-drain method is effective, reducing postoperative pain, hospitalization times and duration of drainage in patients who undergo a lobectomy. Moreover, the single-drain method does not increase the occurrence of postoperative complications and re-drainage rates.

  19. Hydro-geochemistry and retention of phosphorus in drainage filters and constructed wetlands

    DEFF Research Database (Denmark)

    Canga, Eriona; Kjærgaard, Charlotte; Iversen, Bo Vangsø

    Research Council, aims at providing the scientific basis for developing cost-effective filter technologies targeting P-retention and N-removal in agricultural subsurface drainage. The project studies different approaches of implementing the filter technologies including drainage well filters as well...... typically applied to point sources. This calls for a shift of paradigm towards the development of new, cost-efficient technologies to mitigate site-specific nutrient losses in drainage. A newly launched Danish research project “SUPREME-TECH” (2010-2015) (www.supreme-tech.dk) funded by the Danish Strategic...... in drainage water to below environmental threshold values (

  20. Remaining Sites Verification Package for the 1607-F4 Sanitary Sewer System. Attachment to Waste Site Reclassification Form 2004-131

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2007-01-01

    The 1607-F4 waste site is the former location of the sanitary sewer system that serviced the former 115-F Gas Recirculation Building. The system included a septic tank, drain field, and associated pipeline that were in use from 1944 to 1965. The 1607-F4 waste site received unknown amounts of sanitary sewage from the 115-F Gas Recirculation Building and may have potentially contained hazardous and radioactive contamination. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River

  1. Inter-Event Time Definition Setting Procedure for Urban Drainage Systems

    Directory of Open Access Journals (Sweden)

    Jingul Joo

    2013-12-01

    Full Text Available Traditional inter-event time definition (IETD estimate methodologies generally take into account only rainfall characteristics and not drainage basin characteristics. Therefore, they may not succeed in providing an appropriate value of IETD for any sort of application to the design of urban drainage system devices. To overcome this limitation, this study presents a method of IETD determination that considers basin characteristics. The suggested definition of IETD is the time period from the end of a rainfall event to the end of a direct runoff. The suggested method can identify the independent events that are suitable for the statistical analysis of the recorded rainfall. Using the suggested IETD, the IETD of the Joong-Rang drainage system was determined and the area-IETD relation curve was drawn. The resulting regression curve can be used to determinate the IETD of ungauged urban drainage systems, with areas ranging between 40 and 4400 ha. Using the regression curve, the IETDs and time distribution of the design rainfall for four drainage systems in Korea were determined and rainfall-runoff simulations were performed with the Storm Water Management Model (SWMM. The results were compared with those from Huff's method which assumed a six-hour IETD. The peak flow rates obtained by the suggested method were 11%~15% greater than those obtained by Huff’s method. The suggested IETD determination method can identify independent events that are suitable for the statistical analysis of the recorded rainfall aimed at the design of urban drainage system devices.

  2. Flooding the sanitary city : Planning discourse and the materiality of urban sanitation in Hanoi

    OpenAIRE

    Schramm, S.

    2016-01-01

    Urban water flows are constitutive elements of Hanoi’s morphology. Regular floods across the city illustrate that Hanoi’s amphibious character is a central impediment to the installa- tion of a ‘dry and sanitary city’, the global modernist ideal of a separation of urban waste- water flows from public space through their redirection into large underground networks. Currently, the first attempt by the city government to construct a citywide sewerage network since the colonial period is taking p...

  3. Preoperative biliary drainage for periampullary tumors causing obstructive jaundice; DRainage vs. (direct) OPeration (DROP-trial)

    NARCIS (Netherlands)

    N.A. van der Gaag (Niels); S.M.M. de Castro (Steve); E.A.J. Rauws (Erik); M.J. Bruno (Marco); C.H.J. van Eijck (Casper); E.J. Kuipers (Ernst); J.J.G.M. Gerritsen (Josephus); J.P. Rutten (Joost Paul); J.W. Greve; E.J. Hesselink (Eric); J.H. Klinkenbijl (Jean); I.H.M.B. Rinkes; D. Boerma (Djamila); B.A. Bonsing (Bert); C.J. van Laarhoven (Cees); F.J. Kubben; E. van der Harst (Erwin); M.N. Sosef (Meindert); K. Bosscha (Koop); I.H.J.T. de Hingh (Ignace); L. Th de Wit (Laurens); O.M. van Delden (Otto); O.R.C. Busch (Olivier); T.M. van Gulik (Thomas); P.M.M. Bossuyt (Patrick); D.J. Gouma (Dirk)

    2007-01-01

    textabstractBackground. Surgery in patients with obstructive jaundice caused by a periampullary (pancreas, papilla, distal bile duct) tumor is associated with a higher risk of postoperative complications than in non-jaundiced patients. Preoperative biliary drainage was introduced in an attempt to

  4. Acidity and alkalinity in mine drainage: Theoretical considerations

    Science.gov (United States)

    Kirby, Carl S.; Cravotta,, Charles A.

    2004-01-01

    Acidity, net acidity, and net alkalinity are widely used parameters for the characterization of mine drainage, but these terms are not well defined and are often misunderstood. Incorrect interpretation of acidity, alkalinity, and derivative terms can lead to inadequate treatment design or poor regulatory decisions. We briefly explain derivations of theoretical expressions of three types of alkalinities (caustic, phenolphthalein, and total) and acidities (mineral, CO2, and total). Theoretically defined total alkalinity is closely analogous to measured alkalinity and presents few practical interpretation problems. Theoretically defined “CO2- acidity” is closely related to most standard titration methods used for mine drainage with an endpoint pH of 8.3, but it presents numerous interpretation problems, and it is unfortunately named because CO2 is intentionally driven off during titration of mine-drainage samples. Using the proton condition/massaction approach and employing graphs for visualization, we explore the concept of principal components and how to assign acidity contributions to solution species, including aqueous complexes, commonly found in mine drainage. We define a comprehensive theoretical definition of acidity in mine drainage on the basis of aqueous speciation at the sample pH and the capacity of these species to undergo hydrolysis to pH 8.3. This definition indicates the computed acidity in milligrams per liter (mg L-1 ) as CaCO3 (based on pH and analytical concentrations of dissolved FeIII , FeII , Mn, and Al in mg L-1 ): Aciditycomputed = 50. (10(3-pH) + 3.CFeIII/55.8 + 2.CFeII/55.8 + 2.CMn/54.9 + 3.CAl/27.0) underestimates contributions from HSO4 - and H+ , but overestimates the acidity due to Fe3+. These errors tend to approximately cancel each other. We demonstrate that “net alkalinity” is a valid mathematical construction based on theoretical definitions of alkalinity and acidity. We demonstrate that, for most mine-drainage solutions, a

  5. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines), Waste Site Reclassification Form 2007-028

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-12-03

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  6. Drainage Systems Effect on Surgical Site Infection in Children with Perforated Appendicitis

    Directory of Open Access Journals (Sweden)

    Seref Kilic

    2016-09-01

    Full Text Available Aim: Effect of replacing open drainage system to closed drainage system on surgical site infection (SSI in children operated for perforated appendicitis was evaluated. Material and Method: Hospital files and computer records of perforated appendicitis cases operated in 2004-2010 were evaluated retrospectively. Open drainage systems were used for 70 in cases (group I and closed systems were used in the others (group II. Results: Eleven of SSI cases had superficial infection and 3 had the organ/space infection. SSI rate was 15.7% for group I and 7.5% for the group II. The antibiotic treatment length was 7.5 ± 3.4 days for group I and 6.4 ± 2.2 days for group II and the difference between groups was not statistically significant. Hospitalization length for group I was 8.2 ± 3.1 days and 6.8 ± 1.9 days for group II and the difference was statistically significant. Discussion: SSI is an important problem increasing morbidity and treatment costs through increasing hospitalization and antibiotic treatment length. Open drainage system used in operation in patients with perforated appendicitis leads an increased frequency of SSI when compared to the closed drainage system. Thus, closed drainage systems should be preferred in when drainage is necessary in operations for perforated appendicitis in children.

  7. Delineation of a Re-establishing Drainage Network Using SPOT and Landsat Images

    Science.gov (United States)

    Bailey, J. E.; Self, S.; Mouginis-Mark, P. J.

    2008-12-01

    The 1991 eruption of Mt. Pinatubo, The Philippines, provided a unique opportunity to study the effects on the landscape of a large eruption in part because it took place after the advent of regular satellite-based observations. The eruption formed one large (>100km2) ignimbrite sheet, with over 70% of the total deposit deposited in three primary drainage basins to the west of the volcano. High-resolution (20 m/pixel) satellite images, showing the western drainage basins and surrounding region both before and after the eruption were used to observe the re-establishment and evolution of drainage networks on the newly emplaced ignimbrite sheet. Changes in the drainage networks were delineated from a time series of SPOT (Satellite Pour l'Observation de la Terre) and Landsat multi-spectral satellite images. The analysis of which was supplemented by ground- based observations. The satellite images showed that the blue prints for the new drainage systems were established early (within days of the eruption) and at a large-scale followed the pre-eruption pattern. However, the images also illustrated the ephemeral nature of many channels due to the influence of secondary pyroclastic flows, lahar- dammed lake breakouts, stream piracy and shifts due to erosion. Characteristics of the defined drainage networks were used to infer the relative influence on the lahar hazard within each drainage basin.

  8. Infected Baerveldt Glaucoma Drainage Device by Aspergillus niger

    Directory of Open Access Journals (Sweden)

    Nurul-Laila Salim

    2015-01-01

    Full Text Available Fungal endophthalmitis is rare but may complicate glaucoma drainage device surgery. Management is challenging as the symptoms and signs may be subtle at initial presentation and the visual prognosis is usually poor due to its resistant nature to treatment. At present there is lesser experience with intravitreal injection of voriconazole as compared to Amphotericin B. We present a case of successfully treated Aspergillus endophthalmitis following Baerveldt glaucoma drainage device implantation with intravitreal and topical voriconazole.

  9. Technical note on drainage systems

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby

    This technical note will present simple but widely used methods for the design of drainage systems. The note will primarily deal with surface water (rainwater) which on a satisfactorily way should be transport into the drainage system. Traditional two types of sewer systems exist: A combined system......, where rainwater and sewage is transported in the same pipe, and a separate system where the two types of water are transported in individual pipe. This note will only focus on the separate rain/stormwater system, however, if domestic sewage should be included in the dimensioning procedure, it......’s not major different than described below - just remember to include this contribution for combined systems where the surface water (rain) and sewage are carried in the same pipes in the system and change some of the parameters for failure allowance (this will be elaborated further later on). The technical...

  10. Successful percutaneous transperineal drainage of a large prostatic abscess.

    Science.gov (United States)

    Mason, Barry M; Hakimi, A Ari; Clerkin, Kevin J; Silva, Jose V

    2010-12-01

    We present a case of an 83-year-old man with septic shock secondary to an extremely large prostatic abscess. Antibiotics and transperineal percutaneous drainage with a suprapubic-type Malecot catheter successfully treated the abscess. Follow-up images reveal resolution of the abscess. Broad-spectrum antibiotics and drainage permitted a full recovery. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. Participation and partnerships in sanitation imporvement in informal ...

    African Journals Online (AJOL)

    Informal housing settlements provide shelter to the majority of urban poor in Tanzania. However, most of the informal settlements are characterized by among others, lack of or inadequate basic services like roads and drainage, uncollected solid and liquid waste and drinking water and sanitary facilities. Buguruni Mnyamani ...

  12. 40 CFR 503.9 - General definitions.

    Science.gov (United States)

    2010-07-01

    ..., sanitary district, utility district, drainage district, or similar entity, or an integrated waste... that can be applied to a unit area of land (e.g., gallons per acre). (v) Runoff is rainwater, leachate... owned, publicly owned, or privately owned device or system used to treat (including recycle and reclaim...

  13. Drainage filter technologies to mitigate site-specific phosphorus losses

    DEFF Research Database (Denmark)

    Kjærgaard, Charlotte; Heckrath, Goswin Johann; Iversen, Bo Vangsø

    2014-01-01

    -specific nutrient losses in drainage. The “SUPREME-TECH” project (2010-2015), funded by the Danish Strategic Research Council, aims at providing the scientific basis for developing cost-effective drainage filter technologies to retain P in agricultural drainage waters. The project studies different approaches...... high risks areas of P loss and applying site-specific measures therefore seems a more cost-efficient approach. The Danish Commission for Nature and Agriculture has now called for a shift of paradigm towards targeted mitigation and development of new, cost-efficient technologies to mitigate site......-scale surface-flow constructed wetland. In the former, various natural and industrial P filter substrates have been tested for their ability to reduce inlet P concentrations to below environmental threshold values (

  14. The rule on granting subsidies for survey of hot drainage influences

    International Nuclear Information System (INIS)

    1977-01-01

    The rule is based on the prescriptions of the Law Concerning Proper Budget Enforcement on Subsidies and its Enforcement Order. These rules apply to the granting subsidies provided for by the Enforcement Order for the Special Account Law for Measures Promoting Power Source Development. Terms are defined, such as nuclear power generating facilities; arrangement work for equipments for surveying hot drainage influences; work of preliminary survey of hot drainage; work of surveying hot drainage influences; establishments, etc. The Minister of International Trade and Industry delivers the subsidies for all or a part of the expenses necessary for arrangement work of equipments for surveying hot drainage influences, work of preliminary survey of hot drainage and work of surveying hot drainage influences to the prefectures where nuclear power generating facilities have been or are to be set up, or their neighboring prefectures. Terms of delivery concerning an establishment vary from two years to four years according to the kinds of such subsidies. Limits of the subsidies concerning an establishment range from 10 million yen to 2.5 million yen. The applicant prefecture files the application to the Minister of International Trade and Industry. The Minister examines such applications, and notifies his decision to the applicants. Conditions on delivery, reports submitted by receivers of the subsidies and other matters related are specified. (Okada, K.)

  15. 25 CFR 211.47 - Diligence, drainage and prevention of waste.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Diligence, drainage and prevention of waste. 211.47... TRIBAL LANDS FOR MINERAL DEVELOPMENT Rents, Royalties, Cancellations and Appeals § 211.47 Diligence, drainage and prevention of waste. The lessee shall: (a) Exercise diligence in mining, drilling and...

  16. The Seepage Simulation of Single Hole and Composite Gas Drainage Based on LB Method

    Science.gov (United States)

    Chen, Yanhao; Zhong, Qiu; Gong, Zhenzhao

    2018-01-01

    Gas drainage is the most effective method to prevent and solve coal mine gas power disasters. It is very important to study the seepage flow law of gas in fissure coal gas. The LB method is a simplified computational model based on micro-scale, especially for the study of seepage problem. Based on fracture seepage mathematical model on the basis of single coal gas drainage, using the LB method during coal gas drainage of gas flow numerical simulation, this paper maps the single-hole drainage gas, symmetric slot and asymmetric slot, the different width of the slot combined drainage area gas flow under working condition of gas cloud of gas pressure, flow path diagram and flow velocity vector diagram, and analyses the influence on gas seepage field under various working conditions, and also discusses effective drainage method of the center hole slot on both sides, and preliminary exploration that is related to the combination of gas drainage has been carried on as well.

  17. Sanitary Landfill groundwater monitoring report. Fourth quarterly report and summary 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    Fifty-seven wells of the LFW series monitor groundwater quality in Steed Pond Aquifer (Water Table) beneath the Sanitary Landfill at the Savannah River Site (SRS). These wells are sampled quarterly to comply with the South Carolina Department of Health and Environmental Control Domestic Waste Permit DWP-087A and as part of the SRS Groundwater Monitoring Program. Dichloromethane a common laboratory contaminant, and trichloroethylene were the most widespread constituents exceeding standards during 1993. Benzene, chlorobenzene, chloroethene 1,2 dichloroethane, 1,1-dichloroethylene, 1,2-dichloropropane, gross alpha, lindane, mercury, tetrachloroethylene, and tritium also exceeded standards in one or more wells. No groundwater contaminants were observed in wells screened in the lower section of Steed Pond Aquifer.

  18. [The primary medical sanitary care and characteristics of drinking water supply of population].

    Science.gov (United States)

    Nechaev, V S; Saurina, O S

    2016-01-01

    The article considers characteristics of organization ofprimary medical sanitary care on territory with carcinogenic risks related to drinking water supply as exemplified by the Orlovskaia oblast. The importance of registration by local health authorities the sources of permanent chemical pollution of drinking water. The analysis of the State program of the Orlovskaia oblast “The development of health care in the Orlovskaia oblast in 2013-2020". The necessity of additional inclusion of issue related to healthy drinking water supply of population to prevent development of malignant neoplasms and prevalence of oncologic morbidity on oblast territory.

  19. Project of law relative to the sanitary consequences of French nuclear weapons tests

    International Nuclear Information System (INIS)

    2009-05-01

    In order to make easy the indemnifications and to include the persons having participate to nuclear weapons tests (Sahara and French Polynesia) and populations leaving in the concerned areas, the project of law relative to the repair of sanitary consequences of nuclear weapons tests proposes to create a right to integral repair of prejudices for the persons suffering of a radioinduced disease coming from these tests. The American example and the British example are given for comparison. The modalities of financing are detailed as well as the social economic and administrative impacts. (N.C.)

  20. Role of endoscopic biliary drainage in advanced hepatocellular carcinoma with jaundice.

    Science.gov (United States)

    Woo, Hyun Young; Han, Sung Yong; Heo, Jeong; Kim, Dong Uk; Baek, Dong Hoon; Yoo, So Yong; Kim, Chang Won; Kim, Suk; Song, Geun Am; Cho, Mong; Kang, Dae Hwan

    2017-01-01

    Patients with advanced hepatocellular carcinoma (HCC) with jaundice have an extremely poor prognosis. Although biliary drainage can resolve obstructive jaundice, signs of obstruction may not be evident. This study evaluated the role of endoscopic biliary drainage in patients with advanced HCC and obstructive jaundice. From 2010 to 2015, 74 patients underwent endoscopic biliary drainage for obstructive jaundice due to advanced HCC. Jaundice resolution was defined as complete response and total bilirubin concentration below 3 mg/dl. The technical success rate in the 74 patients was 92.1% (70/76). Of the 70 patients who underwent successful biliary drainage, 48 (68.6%) and 22 (31.4%) were Child-Pugh classes B and C, respectively, and 10 (14.3%) and 60 (85.7%) were BCLC stages B and C, respectively. Intrahepatic bile duct (IHD) dilatation was observed in 35 patients (50%). After drainage, the complete response rate was 35.7% (25/70). The mean time to resolution was 17.4 ±8.5 days. However, jaundice was re-aggravated in 74.3% (15/25) after a mean 103.5 ±96.4 days. Multivariate analysis showed that the absence of ascites, presence of IHD dilatation, normal range of prothrombin time, and lower MELD score were significantly associated with complete response. The overall survival rate was 15.7% (11/70) and the median survival time is 28 days (95% confidence interval 2.6-563 days). Complete response and HCC treatment after drainage were significantly associated with survival. Effective endoscopic biliary drainage is an important palliative treatment in patients with advanced HCC and obstructive jaundice, especially those with IHD dilatation and preserved liver function, as determined by ascites, prothrombin time, and MELD score.

  1. Monitoring and remediation technologies of organochlorine pesticides in drainage water

    Directory of Open Access Journals (Sweden)

    Ismail Ahmed

    2015-03-01

    Full Text Available This study was carried out to monitor the presence of organochlorine in drainage water in Kafr-El-Sheikh Governorate, Egypt. Furthermore, to evaluate the efficiencies of different remediation techniques (advanced oxidation processes [AOPs] and bioremediation for removing the most frequently detected compound (lindane in drainage water. The results showed the presence of several organochlorine pesticides in all sampling sites. Lindane was detected with high frequency relative to other detected organochlorine in drainage water. Nano photo-Fenton like reagent was the most effective treatment for lindane removal in drainage water. Bioremediation of lindane by effective microorganisms (EMs removed 100% of the lindane initial concentration. There is no remaining toxicity in lindane contaminated-water after remediation on treated rats relative to control with respect to histopathological changes in liver and kidney. Advanced oxidation processes especially with nanomaterials and bioremediation using effective microorganisms can be regarded as safe and effective remediation technologies of lindane in water.

  2. Preoperative biliary drainage for periampullary tumors causing obstructive jaundice; DRainage vs. (direct) OPeration (DROP-trial)

    NARCIS (Netherlands)

    van der Gaag, Niels A.; de Castro, Steve M. M.; Rauws, Erik A. J.; Bruno, Marco J.; van Eijck, Casper H. J.; Kuipers, Ernst J.; Gerritsen, Josephus J. G. M.; Rutten, Jan-Paul; Greve, Jan Willem; Hesselink, Erik J.; Klinkenbijl, Jean H. G.; Borel Rinkes, Inne H. M.; Boerma, Djamila; Bonsing, Bert A.; van Laarhoven, Cees J.; Kubben, Frank J. G. M.; van der Harst, Erwin; Sosef, Meindert N.; Bosscha, Koop; de Hingh, Ignace H. J. T.; Th de Wit, Laurens; van Delden, Otto M.; Busch, Olivier R. C.; van Gulik, Thomas M.; Bossuyt, Patrick M. M.; Gouma, Dirk J.

    2007-01-01

    BACKGROUND: Surgery in patients with obstructive jaundice caused by a periampullary (pancreas, papilla, distal bile duct) tumor is associated with a higher risk of postoperative complications than in non-jaundiced patients. Preoperative biliary drainage was introduced in an attempt to improve the

  3. Hydrogeochemistry and microbiology of mine drainage: An update

    Science.gov (United States)

    Nordstrom, D. Kirk; Blowes, D.W; Ptacek, C.J.

    2015-01-01

    The extraction of mineral resources requires access through underground workings, or open pit operations, or through drillholes for solution mining. Additionally, mineral processing can generate large quantities of waste, including mill tailings, waste rock and refinery wastes, heap leach pads, and slag. Thus, through mining and mineral processing activities, large surface areas of sulfide minerals can be exposed to oxygen, water, and microbes, resulting in accelerated oxidation of sulfide and other minerals and the potential for the generation of low-quality drainage. The oxidation of sulfide minerals in mine wastes is accelerated by microbial catalysis of the oxidation of aqueous ferrous iron and sulfide. These reactions, particularly when combined with evaporation, can lead to extremely acidic drainage and very high concentrations of dissolved constituents. Although acid mine drainage is the most prevalent and damaging environmental concern associated with mining activities, generation of saline, basic and neutral drainage containing elevated concentrations of dissolved metals, non-metals, and metalloids has recently been recognized as a potential environmental concern. Acid neutralization reactions through the dissolution of carbonate, hydroxide, and silicate minerals and formation of secondary aluminum and ferric hydroxide phases can moderate the effects of acid generation and enhance the formation of secondary hydrated iron and aluminum minerals which may lessen the concentration of dissolved metals. Numerical models provide powerful tools for assessing impacts of these reactions on water quality.

  4. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique.

    Science.gov (United States)

    Dave, Bharat R; Kurupati, Ranganatha Babu; Shah, Dipak; Degulamadi, Devanand; Borgohain, Nitu; Krishnan, Ajay

    2014-01-01

    Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was drainage and ODI (Oswestry Disability Index) score at 2 years. PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts (n = 2), persistent discharge (n = 1) for 2 weeks, blocked catheter (n = 2) and catheter pull out (n = 1) occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.

  5. Sanitary landfill groundwater quality assessment plan Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Wells, D.G.; Cook, J.W.

    1990-06-01

    This assessment monitoring plan has been prepared in accordance with the guidance provided by the SCDHEC in a letter dated December 7, 1989 from Pearson to Wright and a letter dated October 9, 1989 from Keisler to Lindler. The letters are included a Appendix A, for informational purposes. Included in the plan are all of the monitoring data from the landfill monitoring wells for 1989, and a description of the present monitoring well network. The plan proposes thirty-two new wells and an extensive coring project that includes eleven soil borings. Locations of the proposed wells attempt to follow the SCDHEC guidelines and are downgradient, sidegradient and in the heart of suspected contaminant plumes. Also included in the plan is the current Savannah River Site Sampling and Analysis Plan and the well construction records for all of the existing monitoring wells around the sanitary landfill.

  6. Estimation of Parameters and Flow Characteristics for the Design of Sanitary Sewers in Malaysia

    Directory of Open Access Journals (Sweden)

    Kamran Ansari

    2013-01-01

    Full Text Available Determination of the flow characteristics is very important for the design of sanitary sewers in any area. In the present study these are determined in the running sewers for the two parameters; per capita flow contribution and the peak flow factor. ISCO area - velocity flow meter model 4250 is used for this purpose. The flow meter, before being used in the running sewers, is calibrated first in the Hydraulics and Hydrology Laboratory of the UTM (Universiti Teknologi Malaysia. During the study the flow meter is installed inside the manhole in 10 different phases in the months of June, August, September, and October 2005 to monitor the sewage flow running in it. Continuous data is recorded in the flow meter during the process and the recorded time varies between 47 hours 25 minutes and 128 hours 35 minutes. The rainfall data is also collected during the same time using an automatic rain gauge which recorded rainfall at every five minutes of interval. Both the parameters thus calculated are then compared with the Malaysian Standard for sewer design i.e. MS 1228:1991. The results show that higher values of these parameters are being used in the design of sanitary sewers and extensive study needs to be carried out to review these values for future use

  7. Physical and sanitary quality of soybean seeds produced in the state of Santa Catarina

    Directory of Open Access Journals (Sweden)

    Volmir Frandoloso

    2015-08-01

    Full Text Available Soybean production accounts for approximately 43% of Brazil’s grain produce, worth over 81 million tons for the 2012- 2013 cropping season. The use of quality seeds is essential for a high-yield agriculture, since low quality seeds compromise plant standing and increase production costs due to reseeding. This will in turn reduce yields through delays on the establishment dates. Seed quality is affected by relative humidity levels, mechanical damage during harvest and processing, thermal damage during the drying process and the environmental conditions during storage that could foster insect and fungi damage. The climate in the state of Santa Catarina favors soybean seed production, and seed companies in general work with high levels of technology. This work is aimed at characterizing the physical and sanitary quality of soybean seeds produced by different companies at different locations throughout the state of Santa Catarina (municipalities of Xanxerê, Abelardo Luz, Campos Novos and Canoinhas. The physical purity, moisture level, sanitary quality and mechanical damage of soybean seeds were studied at three stages, i.e. reception at the seed processing unit, at the end of the processing process and before being marketed. Results pointed out at mechanical injury and cultivar mixture as the main issues concerning seed lot quality, and that soybean seeds produced in Santa Catarina show pathogen contamination, which emphasizes the need for seed treatment.

  8. CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections

    International Nuclear Information System (INIS)

    Marano, I.; Mainenti, P.P.; Selva, G.; Cannavale, M.; Sodano, A.

    1999-01-01

    The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections [it

  9. Continuous Passive Sampling of Solutes from Agricultural Subsurface Drainage Tubes

    Science.gov (United States)

    Lindblad Vendelboe, Anders; de Jonge, Hubert; Rozemeijer, Joachim; Wollesen de Jonge, Lis

    2015-04-01

    Agricultural subsurface tube drain systems play an important role in water and solute transport. One study, focusing on lowland agricultural catchments, showed that subsurface tube drainage contributed up to 80% of the annual discharge and 90% of the annual NO3 load from agricultural fields to the receiving water bodies. Knowledge of e.g. nutrient loads and drainage volumes, based on measurements and modelling, are important for adequate water quality management. Despite the importance of tube drain transport of solutes, monitoring data are scarce. This scarcity is a result of the existing monitoring techniques for flow and contaminant load from tube drains being expensive and labor-extensive. The study presented here aimed at developing a cheap, simple, and robust method to monitor solute loads from tube drains. The method is based on the newly developed Flowcap, which can be attached to existing tube drain outlets and can measure total flow, contaminant load and flow-averaged concentrations of solutes in the drainage. The Flowcap builds on the existing Sorbicell principle, a passive sampling system that measures average concentrations over longer periods of time (days to months) for various compounds. The Sorbicell consists of two compartments permeable to water. One compartment contains an adsorbent and one contains a tracer. When water passes through the Sorbicell the compound of interest is absorbed while a tracer is released. Using the tracer loss to calculate the volume of water that has passed the Sorbicell it is possible to calculate the average concentration of the compound. When mounting Sorbicells in the Flowcap, a flow-proportional part of the drainage is sampled from the main stream. To accommodate the wide range of drainage flow rates two Flowcaps with different capacities were tested in the laboratory: one with a capacity of 25 L min-1 (Q25) and one with a capacity of 256 L min-1 (Q256). In addition, Sorbicells with two different hydraulic

  10. Feasibility study of a self-remediation system for mine drainage using its thermal energy

    Science.gov (United States)

    Oh, Chamteut; Cheong, Youngwook; Yim, Giljae; Ji, Sangwoo

    2016-04-01

    Mine drainage is defined as the water which is discharged to the ground surface through shafts and/or cracks formed by mining activities. Typically, mine drainage features high concentration of acidity and metals since it passes through the underground. Therefore, for the purpose of protecting the surrounding natural environment, mine drainage should be remediated before being discharged to nature. Mine drainage, due to its nature of being retained underground, shows constant temperature which is independent from the temperature of the atmosphere above ground. This condition allows mine drainage to become a promising renewable energy source since energy can be recovered from water with constant temperature. In this research, a self-remediation system is proposed which remediates the mine drainage through electrochemical reactions powered by the thermal energy of mine drainage. High energy efficiency is able to be achieved by shortening the distance between the energy source and consumption, and therefore, this system has a strong advantage to be actualized. A feasibility study for the system was conducted in this research where the thermal energy of mine drainage over time and depth was calculated as energy supply and the required electrical energy for remediating the mine drainage was measured as energy consumption. While the technology of converting thermal energy directly into electrical energy is yet to be developed, energy balance analysis results showed that the proposed self-remediation system is theoretically possible.

  11. Evaluation of the sanitary and environmental risks resulting from the Erika sinking and from the coasts cleaning operations

    International Nuclear Information System (INIS)

    Cicolella, A.

    2000-03-01

    This synthesis presents the methodology of the risks evaluation and of the INERIS report, the products analysis, general data on polycyclic aromatic hydrocarbons, the exposure evaluation, the sanitary impact evaluation for the polycyclic organic hydrocarbons and volatile organic compounds and the evaluation of ecological risks. (A.L.B.)

  12. How internal drainage affects evaporation dynamics from soil surfaces ?

    Science.gov (United States)

    Or, D.; Lehmann, P.; Sommer, M.

    2017-12-01

    Following rainfall, infiltrated water may be redistributed internally to larger depths or lost to the atmosphere by evaporation (and by plant uptake from depths at longer time scales). A large fraction of evaporative losses from terrestrial surfaces occurs during stage1 evaporation during which phase change occurs at the wet surface supplied by capillary flow from the soil. Recent studies have shown existence of a soil-dependent characteristic length below which capillary continuity is disrupted and a drastic shift to slower stage 2 evaporation ensues. Internal drainage hastens this transition and affect evaporative losses. To predict the transition to stage 2 and associated evaporative losses, we developed an analytical solution for evaporation dynamics with concurrent internal drainage. Expectedly, evaporative losses are suppressed when drainage is considered to different degrees depending on soil type and wetness. We observe that high initial water content supports rapid drainage and thus promotes the sheltering of soil water below the evaporation depth. The solution and laboratory experiments confirm nonlinear relationship between initial water content and total evaporative losses. The concept contributes to establishing bounds on regional surface evaporation considering rainfall characteristics and soil types.

  13. Assessment of the functional validity of hydrocephalus drainages by means of scintigraphy

    International Nuclear Information System (INIS)

    Mueller, J.; Endert, G.

    1980-01-01

    The assessment of the functional validity of hydrocephalus drainages is an as yet insolved problem. Several criteria and methods are discussed and a sup(99m)Tc-pertechnetate scintigraphy enabling an evaluation of the drainage function is presented. In case of a stop in the drainage system the surgeon can also obtain certain information about its localization. Out of 30 children, the method showed a sufficient cerebrospinal fluid flow in 14 and an insufficient one in 16 patients, respectively. In 8 children of the latter group the result was confirmed by following operation. 4 children have obviously no longer need of drainage after a period of 5 years or more. (author)

  14. Changing drainage patterns within South Cascade Glacier, Washington, USA, 1964-1992

    Science.gov (United States)

    Fountain, A.G.; Vaughn, B.H.

    1995-01-01

    The theoretical patterns of water drainage are presented for South Cascade Glacier for four different years between 1964 and 1992, during which the glacier was thinning and receding. The theoretical pattern compares well, in a broad sense, with the flow pattern determined from tracer injections in 1986 and 1987. Differences between the patterns may result from the routing of surface meltwater in crevasses prior to entering the body of the glacier. The changing drainage pattern was caused by glacier thinning. The migration of a drainage divide eventually rerouted most of the surface meltwater from the main stream that drained the glacier in 1987 to another, formerly smaller, stream by 1992. On the basis of projected glacier thinning between 1992 and 1999, we predict that the drainage divide will continue to migrate across the glacier.

  15. Automatic Generalizability Method of Urban Drainage Pipe Network Considering Multi-Features

    Science.gov (United States)

    Zhu, S.; Yang, Q.; Shao, J.

    2018-05-01

    Urban drainage systems are indispensable dataset for storm-flooding simulation. Given data availability and current computing power, the structure and complexity of urban drainage systems require to be simplify. However, till data, the simplify procedure mainly depend on manual operation that always leads to mistakes and lower work efficiency. This work referenced the classification methodology of road system, and proposed a conception of pipeline stroke. Further, length of pipeline, angle between two pipelines, the pipeline belonged road level and diameter of pipeline were chosen as the similarity criterion to generate the pipeline stroke. Finally, designed the automatic method to generalize drainage systems with the concern of multi-features. This technique can improve the efficiency and accuracy of the generalization of drainage systems. In addition, it is beneficial to the study of urban storm-floods.

  16. Drainage of the ice-dammed Lake Tinninilik, West Greenland; implication on bedrock uplift

    DEFF Research Database (Denmark)

    Kjeldsen, Kristian Kjellerup; Khan, Shfaqat Abbas; Bjørk, Anders Anker

    Drainage of ice-dammed lakes is regularly observed along the margin of the Greenland Ice Sheet. However, the speed of the drainage events and implications can vary depending on the size of the lakes and the local settings. Here, we assess the drainage pattern of Lake Tinninilik, dammed...

  17. Using bamboo (Bambusa vulgaris) as a field drainage material in ...

    African Journals Online (AJOL)

    Bamboo (Bambusa vulgaris), one of the most widespread member of its genus, was used as field drainage material in Akure, Nigeria. Pre-determined sizes of bamboo with uniform lengths and diameters were installed as sub-drains in agricultural field for drainage purposes, especially in developing countries like Nigeria.

  18. Update summary of the 1991 discharge of enriched uranium to the sanitary sewer (DEUSS) report

    International Nuclear Information System (INIS)

    1995-04-01

    Since the 1991 Y-12 Plant report, a flow study of the Y-12 Plant sanitary sewer collection system has been completed by the Y-12 Plant staff (Hanzelka and Maguire, 1993). Additional data has been obtained by the Y-12 Plant and the City of Oak Ridge (COR, 1994). COR developed limits on radionuclide concentrations in sludges used for land application (Stetar, 1993). Martin Marietta Energy Systems has provided recommendations to the Department of Energy (DOE) regarding the impacts of sludge land farming operations on the ORR (Frye, 1992). The DOE Office of Nuclear Safety (USDOE, 1993) completed an audit of activities related to radiological contamination of the COR sewer system due to DOE operations. In addition COR is currently developing limits on radionuclide releases for all industrial customers to be applied through the permitting process. In 1994, a new sanitary sewer monitoring station was installed and began operation at the Y-12 Plant to determine releases specifically from the Y-12 Plant. Previously, estimates were based on mass balance calculations using data from the City Monitoring Station which monitors Union Valley and Y-12 Plant releases. The purpose of this report is to update the 1991 Y-12 Plant study taking into account current data and information

  19. Geomorphologic Analysis of Drainage Basins in Damavand Volcano Cone, Iran

    Science.gov (United States)

    Zareinejad, M.

    2011-12-01

    Damavand volcanic cone is located in the center of the Alborz chain, in the southern Caspian Sea in Iran. Damavand is a dormant volcano in Iran. It is not only the country's highest peak but also the highest mountain on the Middle East; its elevation is 5619 m. The main purpose of this paper is recognition and appraisement of drainage basins in Damavand cone from geomorphic point of view. Water causes erosion in nature in different forms and creates diverse forms on the earth surface depending on the manner of its appearance in nature. Although water is itself a former factor, it flows under morphological effect of earth surface. The difference of earth surface topography and as a result water movement on it, cause the formation of sub-basins. Identification of region drainage basins is considered as one of the requirements for Damavand cone morphometric. Thereupon, five drainage basins were identified in this research by relying on main criteria including topographic contours with 10 m intervals, drainage system, DEM map, slope map, aspect map and satellite images. (Fig 1) Area, perimeter, height classification for classifying morphological landforms in different levels, hypsometric calculations, drainage density, etc. were then calculated by using ArcGIS software. (Table 1) Damavand cone, with a height more than 5,000 meters from the sea surface, has very hard pass slopes and our purpose in this paper is to identify the effect of drainage basins conditions in the region on erosion and the formation of morphological landforms by using SPOT, ASTER, satellite images as well as papering of data in GIS environment.

  20. Observing a catastrophic thermokarst lake drainage in northern Alaska

    Science.gov (United States)

    Jones, Benjamin M.; Arp, Christopher D.

    2015-01-01

    The formation and drainage of thermokarst lakes have reshaped ice-rich permafrost lowlands in the Arctic throughout the Holocene. North of Teshekpuk Lake, on the Arctic Coastal Plain of northern Alaska, thermokarst lakes presently occupy 22.5% of the landscape, and drained thermokarst lake basins occupy 61.8%. Analysis of remotely sensed imagery indicates that nine lakes (>10 ha) have drained in the 1,750 km2 study area between 1955 and 2014. The most recent lake drainage was observed using in situ data loggers providing information on the duration and magnitude of the event, and a nearby weather station provided information on the environmental conditions preceding the lake drainage. Lake 195 (L195), an 80 ha thermokarst lake with an estimated water volume of ~872,000 m3, catastrophically drained on 05 July 2014. Abundant winter snowfall and heavy early summer precipitation resulted in elevated lake water levels that likely promoted bank overtopping, thermo-erosion along an ice-wedge network, and formation of a 9 m wide, 2 m deep, and 70 m long drainage gully. The lake emptied in 36 hours, with 75% of the water volume loss occurring in the first ten hours. The observed peak discharge of the resultant flood was 25 m3/s, which is similar to that in northern Alaska river basins whose areas are more than two orders of magnitude larger. Our findings support the catastrophic nature of sudden lake drainage events and the mechanistic hypotheses developed by J. Ross Mackay.

  1. Total anomalous systemic venous drainage in left heterotaxy syndrome.

    Science.gov (United States)

    Khandenahally, Ravindranath S; Deora, Surender; Math, Ravi S

    2013-04-01

    Total anomalous systemic venous drainage is an extremely rare congenital heart defect. In this study we describe an 11-year-old girl who presented with a history of fatigue and central cyanosis that she had had since early childhood with unremarkable precordial examination results. Investigations revealed left heterotaxy with all systemic venous drainage to the left-sided atrium with non-compaction of the left ventricle.

  2. Unilobar versus bilobar biliary drainage: effect on quality of life and bilirubin level reduction

    Directory of Open Access Journals (Sweden)

    Shivanand Gamanagatti

    2016-01-01

    Conclusion: Percutaneous biliary drainage provides good palliation of malignant obstructive jaundice. Partial-liver drainage achieved results as good as those after complete liver drainage with significant improvements in QOL and reduction of the bilirubin level.

  3. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  4. Nocturnal drainage wind characteristics in two converging air sheds

    International Nuclear Information System (INIS)

    Gedayloo, T.; Clements, W.E.; Barr, S.; Archuleta, J.A.

    1980-01-01

    During the short experimental period in the Grants Basin of Northeastern New Mexico a survey was conducted on the complex meteorology of this area. Emphasis was placed on the nocturnal drainage flow because of the potential hazards to the populated areas of Milan and Grants from the effluents of the uranium mining and milling operation in this area. This investigation has shown that the nocturnal drainage flow patterns agree with the winds predicted on the basis of the complex terrain of the area. Because of the surface cooling at night (over 25 0 C during summer and about 20 0 C during winter), air from elevated surrounding areas flows to the low lying regions consequently setting up a nocturnal drainage flow. This regime exists over 60% of the time during summer months and over 65% of the time during winter months with a depth generally less than 200 m. In the San Mateo air shed the drainage flow is east northeast, and in the Ambrosia Lake air shed it is from northwest. The confluence of these two air flows contributes mainly to the drainage flow through the channel formed by La Ja Mesa and Mesa Montanosa. The analysis of data collected by the recording Flats Station confirms the prediction that although the area south of the channel region broadens considerably causing a reduction in flow speed, contributions from the southside of La Jara Mesa and Mesa Montanosa partly compensate for this reduction. The position of this recording station is 15 to 20 km from the populated towns of Milan and Grants. A drainage flow speed of approximately 2.2 m s -1 and the duration of over 11 hours as recorded by this station indicates that air from the San Mateo and Ambrosia Lake regions may be transported southwards to these population centers during a nocturnal period. In order to test this prediction, a series of multi-atmospheric tracer experiments were conducted in the Grants Basin

  5. The effect of sanitary landfill leachate aging on the biological treatment and assessment of photoelectrooxidation as a pre-treatment process

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Gabriel Timm [Universidade Estadual do Rio Grande do Sul (UERGS), R. Gal. João Manoel, 50, CEP 90010-030 Porto Alegre, RS (Brazil); Giacobbo, Alexandre [Universidade Federal do Rio Grande do Sul (UFRGS), Av. Bento Gonçalves, 9500, Setor 4, Prédio 74, CEP 91501-970 Porto Alegre, RS (Brazil); Santos Chiaramonte, Edson Abel dos [Universidade Estadual do Rio Grande do Sul (UERGS), R. Gal. João Manoel, 50, CEP 90010-030 Porto Alegre, RS (Brazil); Rodrigues, Marco Antônio Siqueira [Universidade FEEVALE, ICET, RS 239, 2755, CEP 93352-000 Novo Hamburgo, RS (Brazil); Meneguzzi, Alvaro [Universidade Federal do Rio Grande do Sul (UFRGS), Av. Bento Gonçalves, 9500, Setor 4, Prédio 74, CEP 91501-970 Porto Alegre, RS (Brazil); Bernardes, Andréa Moura, E-mail: amb@ufrgs.br [Universidade Federal do Rio Grande do Sul (UFRGS), Av. Bento Gonçalves, 9500, Setor 4, Prédio 74, CEP 91501-970 Porto Alegre, RS (Brazil)

    2015-02-15

    Highlights: • Photoelectrooxidation (PEO) emerges as a new technology for leachate treatment. • Aging of sanitary landfills acts on leachate composition and biodegradability. • PEO is applied as leachate pretreatment before the biological processes. • PEO produced significant changes in the leachate matrix, easing biological process. - Abstract: The sanitary landfill leachate is a dark liquid, of highly variable composition, with recalcitrant features that hamper conventional biological treatment. The physical–chemical characteristics of the leachate along the landfill aging, as well as their effects on the efficiency of the conventional treatment, were evaluated at this paper. The feasibility of photoelectrooxidation process as an alternative technique for treatment of landfill leachates was also determined. Photoelectrooxidation experiments were conducted in a bench-scale reactor. Analysis of the raw leachate revealed many critical parameters demonstrating that the recalcitrance of leachate tends to increase with time, directly influencing the decline in efficiency of the conventional treatment currently employed. The effects of current density and lamp power were investigated. Using a 400 W power lamp and a current density of 31.5 mA cm{sup −2}, 53% and 61% efficiency for the removal of ammoniacal nitrogen and chemical oxygen demand were respectively achieved by applying photoelectrooxidation process. With the removal of these pollutants, downstream biological treatment should be improved. These results demonstrate that photoelectrooxidation is a feasible technique for the treatment of sanitary landfill leachate, even considering this effluent’s high resistance to treatment.

  6. The effect of sanitary landfill leachate aging on the biological treatment and assessment of photoelectrooxidation as a pre-treatment process

    International Nuclear Information System (INIS)

    Müller, Gabriel Timm; Giacobbo, Alexandre; Santos Chiaramonte, Edson Abel dos; Rodrigues, Marco Antônio Siqueira; Meneguzzi, Alvaro; Bernardes, Andréa Moura

    2015-01-01

    Highlights: • Photoelectrooxidation (PEO) emerges as a new technology for leachate treatment. • Aging of sanitary landfills acts on leachate composition and biodegradability. • PEO is applied as leachate pretreatment before the biological processes. • PEO produced significant changes in the leachate matrix, easing biological process. - Abstract: The sanitary landfill leachate is a dark liquid, of highly variable composition, with recalcitrant features that hamper conventional biological treatment. The physical–chemical characteristics of the leachate along the landfill aging, as well as their effects on the efficiency of the conventional treatment, were evaluated at this paper. The feasibility of photoelectrooxidation process as an alternative technique for treatment of landfill leachates was also determined. Photoelectrooxidation experiments were conducted in a bench-scale reactor. Analysis of the raw leachate revealed many critical parameters demonstrating that the recalcitrance of leachate tends to increase with time, directly influencing the decline in efficiency of the conventional treatment currently employed. The effects of current density and lamp power were investigated. Using a 400 W power lamp and a current density of 31.5 mA cm −2 , 53% and 61% efficiency for the removal of ammoniacal nitrogen and chemical oxygen demand were respectively achieved by applying photoelectrooxidation process. With the removal of these pollutants, downstream biological treatment should be improved. These results demonstrate that photoelectrooxidation is a feasible technique for the treatment of sanitary landfill leachate, even considering this effluent’s high resistance to treatment

  7. Pseudocyst in the pancreatic tail associated with chronic pancreatitis successfully treated by transpapillary cyst drainage.

    Science.gov (United States)

    Naitoh, Itaru; Ohara, Hirotaka; Okayama, Yasutaka; Nakazawa, Takahiro; Ando, Tomoaki; Hayashi, Kazuki; Okumura, Fumihiro; Kitajima, Yasuhiro; Ban, Tessin; Miyabe, Katsuyuki; Ueno, Koichiro; Joh, Takashi; Sano, Hitoshi

    2008-09-01

    We report a 50-year-old male with pseudocysts in the pancreatic tail associated with chronic pancreatitis successfully treated by transpapillary cyst drainage. He had previously undergone ultrasonography-guided percutaneous cyst drainage for a pancreatic pseudocyst in our hospital. He was readmitted due to abdominal pain and fever. Computed tomography showed recurrence of a pseudocyst in the pancreatic tail measuring 5 cm in diameter. Since conservative treatment failed, endoscopic retrograde pancreatography was performed. There was communication between the pseudocyst and the main pancreatic duct, and pancreatic duct stenosis proximal to the pseudocyst. First, transpapillary pancreatic duct drainage was performed using a plastic stent, but the pseudocyst did not decrease in size and became infected. After removal of the stent, a pigtail type nasocystic catheter was placed in the pseudocyst via the pancreatic duct. The pseudocyst infection immediately disappeared, and the pseudocyst gradually decreased and disappeared. After removal of the nasocystic catheter, no recurrence was observed. As transpapillary drainage of pancreatic pseudocyst, cyst drainage and pancreatic duct drainage have been reported. In our patient with pseudocyst in the pancreatic tail, duct drainage was ineffective and the pseudocyst was infected, whereas cyst drainage was very effective. We considered that cyst drainage by a nasocystic catheter was the first-line therapy as the transpapillary drainage of the pancreatic pseudocyst.

  8. Pseudocyst in the Pancreatic Tail Associated with Chronic Pancreatitis Successfully Treated by Transpapillary Cyst Drainage

    Directory of Open Access Journals (Sweden)

    Itaru Naitoh

    2008-11-01

    Full Text Available We report a 50-year-old male with pseudocysts in the pancreatic tail associated with chronic pancreatitis successfully treated by transpapillary cyst drainage. He had previously undergone ultrasonography-guided percutaneous cyst drainage for a pancreatic pseudocyst in our hospital. He was readmitted due to abdominal pain and fever. Computed tomography showed recurrence of a pseudocyst in the pancreatic tail measuring 5 cm in diameter. Since conservative treatment failed, endoscopic retrograde pancreatography was performed. There was communication between the pseudocyst and the main pancreatic duct, and pancreatic duct stenosis proximal to the pseudocyst. First, transpapillary pancreatic duct drainage was performed using a plastic stent, but the pseudocyst did not decrease in size and became infected. After removal of the stent, a pigtail type nasocystic catheter was placed in the pseudocyst via the pancreatic duct. The pseudocyst infection immediately disappeared, and the pseudocyst gradually decreased and disappeared. After removal of the nasocystic catheter, no recurrence was observed. As transpapillary drainage of pancreatic pseudocyst, cyst drainage and pancreatic duct drainage have been reported. In our patient with pseudocyst in the pancreatic tail, duct drainage was ineffective and the pseudocyst was infected, whereas cyst drainage was very effective. We considered that cyst drainage by a nasocystic catheter was the first-line therapy as the transpapillary drainage of the pancreatic pseudocyst.

  9. Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).

    Science.gov (United States)

    Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao

    2008-07-01

    The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.

  10. Outcome of ultrasound-guided small-bore catheter drainage in exudative pleural effusions.

    Science.gov (United States)

    Kiranantawat, Nantaka; Sungsiri, Jitpreedee; Geater, Sarayut L

    2014-05-01

    To evaluate the outcome and safety of ultrasound-guided percutaneous catheter drainage of exudative pleural effusion. The present study was a retrospective analysis of 412 pleural effusions from 373 patients that underwent ultrasound-guided small-bore catheter drainage in exudative pleural effusions between 2004 and 2009. The two most common causes for drainage were parapneumonic effusion or empyema (52.2%) and malignant effusion (30.3%), while the remains were trauma, iatrogenic, and others. Overall clinical success rate was 76.5%. The success rate was lower among malignant pleural effusion (p = 0.003). Causes of effusion were the only independent predictors related to success. Only five (1.2%) patients developed complication during the procedure. Seventy-five of 412 effusions (15.8%) developed complication during the period of drainage; the majority were drain blockage (9%) and accidental dislodgment (4.1%). Ultrasound-guided small-bore catheter drainage was a safe and efficient procedure for exudative pleural effusions.

  11. Urban Floods Adaptation and Sustainable Drainage Measures

    Directory of Open Access Journals (Sweden)

    Helena M. Ramos

    2017-11-01

    Full Text Available Sustainability is crucial to the urban zones, especially related to the water management, which is vulnerable to flood occurrence. This research applies the procedure contemplated by the Soil Conservation Service (SCS to determine the generated volumes when the impervious areas can exceed the drainage capacity of existing pluvial water networks. Several computational simulations were developed for the current scenario of an existing basin in Lisbon. Using CivilStorm software from Bentley Systems (Bentley EMEA, Bentley Systems International Limited, Dublin, Ireland, it enabled the evaluation of the volumes of flood peaks and the hydraulic behavior of a small hydrographic basin in the continuation of an urbanization process, considering the modification of its superficial impervious parts and the growth of the urbanized area. Several measures are suggested to solve the limited capacity of the existing drainage system. This study analyzes the efficiency of the application of constructive measures, pondering the viability of their effectiveness, individually and combined. The option that best minimizes the effects of the urbanization is the combination of different structural measures, in particular retention ponds, storage blocks, ditches and specific drainage interventions in some parts of the network.

  12. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique

    OpenAIRE

    Bharat R Dave; Ranganatha Babu Kurupati; Dipak Shah; Devanand Degulamadi; Nitu Borgohain; Ajay Krishnan

    2014-01-01

    Background: Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems...

  13. Lymphatic drainage of lung segments in the visceral pleura: a cadaveric study.

    Science.gov (United States)

    Fourdrain, Alex; Lafitte, Sophie; Iquille, Jules; De Dominicis, Florence; Havet, Eric; Peltier, Johann; Bagan, Patrick; Berna, Pascal

    2018-01-01

    Although peribronchial lymphatic drainage of the lung has been well characterized, lymphatic drainage in the visceral pleura is less well understood. The objective of the present study was to evaluate the lymphatic drainage of lung segments in the visceral pleura. Adult, European cadavers were examined. Cadavers with a history of pleural or pulmonary disease were excluded. The cadavers had been refrigerated but not embalmed. The lungs were surgically removed and re-warmed. Blue dye was injected into the subpleural area and into the first draining visceral pleural lymphatic vessel of each lung segment. Twenty-one cadavers (7 males and 14 females; mean age 80.9 years) were dissected an average of 9.8 day postmortem. A total of 380 dye injections (in 95 lobes) were performed. Lymphatic drainage of the visceral pleura followed a segmental pathway in 44.2% of the injections (n = 168) and an intersegmental pathway in 55.8% (n = 212). Drainage was found to be both intersegmental and interlobar in 2.6% of the injections (n = 10). Lymphatic drainage in the visceral pleura followed an intersegmental pathway in 22.8% (n = 13) of right upper lobe injections, 57.9% (n = 22) of right middle lobe injections, 83.3% (n = 75) of right lower lobe injections, 21% (n = 21) of left upper lobe injections, and 85.3% (n = 81) of left lower lobe injections. In the lung, lymphatic drainage in the visceral pleura appears to be more intersegmental than the peribronchial pathway is-especially in the lower lobes. The involvement of intersegmental lymphatic drainage in the visceral pleura should now be evaluated during pulmonary resections (and especially sub-lobar resections) for lung cancer.

  14. Tile drainage phosphorus loss with long-term consistent cropping systems and fertilization.

    Science.gov (United States)

    Zhang, T Q; Tan, C S; Zheng, Z M; Drury, C F

    2015-03-01

    Phosphorus (P) loss in tile drainage water may vary with agricultural practices, and the impacts are often hard to detect with short-term studies. We evaluated the effects of long-term (≥43 yr) cropping systems (continuous corn [CC], corn-oats-alfalfa-alfalfa rotation [CR], and continuous grass [CS]) and fertilization (fertilization [F] vs. no-fertilization [NF]) on P loss in tile drainage water from a clay loam soil over a 4-yr period. Compared with NF, long-term fertilization increased concentrations and losses of dissolved reactive P (DRP), dissolved unreactive P (DURP), and total P (TP) in tile drainage water, with the increments following the order: CS > CR > CC. Dissolved P (dissolved reactive P [DRP] and dissolved unreactive P [DURP]) was the dominant P form in drainage outflow, accounting for 72% of TP loss under F-CS, whereas particulate P (PP) was the major form of TP loss under F-CC (72%), F-CR (62%), NF-CS (66%), NF-CC (74%), and NF-CR (72%). Dissolved unreactive P played nearly equal roles as DRP in P losses in tile drainage water. Stepwise regression analysis showed that the concentration of P (DRP, DURP, and PP) in tile drainage flow, rather than event flow volume, was the most important factor contributing to P loss in tile drainage water, although event flow volume was more important in PP loss than in dissolved P loss. Continuous grass significantly increased P loss by increasing P concentration and flow volume of tile drainage water, especially under the fertilization treatment. Long-term grasslands may become a significant P source in tile-drained systems when they receive regular P addition. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  15. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique

    Directory of Open Access Journals (Sweden)

    Bharat R Dave

    2014-01-01

    Full Text Available Background: Percutaneous aspiration of abscesses under ultrasonography (USG and computer tomography (CT scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Materials and Methods: Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was <10 ml for 48 hours. Outcome assessment was done with relief of pain, successful abscess drainage and ODI (Oswestry Disability Index score at 2 years. Results: PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts ( n = 2, persistent discharge ( n = 1 for 2 weeks, blocked catheter ( n = 2 and catheter pull out ( n = 1 occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Conclusions: Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.

  16. Detecting Subsurface Agricultural Tile Drainage using GIS and Remote Sensing Technique

    Science.gov (United States)

    Budhathoki, M.; Gokkaya, K.; Tank, J. L.; Christopher, S. F.; Hanrahan, B.

    2015-12-01

    Subsurface tile drainage is a common practice in many of the row crop dominated agricultural lands in the Upper Midwest, which increases yield by making the soil more productive. It is reported that nearly half of all cropland in Indiana benefits from some sort of artificial drainage. However, subsurface tile has a significant negative impact on surface water quality by providing a fast means of transport for nutrients from fertilizers. Therefore, generating spatial data of tile drainage in the field is important and useful for agricultural landscape and hydrological studies. Subsurface tile drains in Indiana's croplands are not widely mapped. In this study, we will delineate subsurface tile drainage in agricultural land in Shatto Ditch watershed, located in Kosciusko County, Indiana. We will use geo-spatial methodology, which was purposed by earlier researchers to detect tile drainage. We will use aerial color-infrared and satellite imagery along with Light Detection and Ranging (LiDAR) data. In order to map tile lines with possible accuracy, we will use GIS-based analysis in combination with remotely sensed data. This research will be comprised of three stages: 1) masking out the potential drainage area using a decision tree rule based on land cover information, soil drainage category, surface slope, and satellite image differencing technique, 2) delineate tile lines using image processing techniques, and 3) check the accuracy of mapped tile lines with ground control points. To our knowledge, this study will be the first to check the accuracy of mapping with ground truth data. Based on the accuracy of results, we will extend the methodology to greater spatial scales. The results are expected to contribute to better characterizing and controlling water pollution sources in Indiana, which is a major environmental problem.

  17. Adaptation Options for Land Drainage Systems Towards Sustainable Agriculture and Environment: A Czech Perspective

    Science.gov (United States)

    Kulhavý, Zbyněk; Fučík, Petr

    2015-04-01

    In this paper, issues of agricultural drainage systems are introduced and discussed from the views of their former, current and future roles and functioning in the Czech Republic (CR). A methodologically disparate survey was done on thirty-nine model localities in CR with different intensity and state of land drainage systems, aimed at description of commonly occurred problems and possible adaptations of agricultural drainage as perceived by farmers, land owners, landscape managers or by protective water management. The survey was focused on technical state of drainage, fragmentation of land ownership within drained areas as well as on possible conflicts between agricultural and environmental interests in a landscape. Achieved results confirmed that there is obviously an increasing need to reassess some functions of prevailingly single-purpose agricultural drainage systems. Drainage intensity and detected unfavourable technical state of drainage systems as well as the risks connected with the anticipated climate change from the view of possible water scarcity claims for a complex solution. An array of adaptation options for agricultural drainage systems is presented, aiming at enhancement of water retention time and improvement of water quality. It encompasses additional flow-controlling measures on tiles or ditches, or facilities for making selected parts of a drainage system inoperable in order to retain or slow down the drainage runoff, to establish water accumulation zones and to enhance water self-cleaning processes. However, it was revealed that the question of landowner parcels fragmentation on drained land in CR would dramatically complicate design and realization of these measures. Presented solutions and findings are propounded with a respect to contemporary and future state policies and international strategies for sustainable agriculture, water management and environment.

  18. The effect of mechanical lymph drainage accompanied with heat on lymphedema.

    Science.gov (United States)

    Mariana, Valente Flávia; de Fátima, Guerreiro Godoy Maria; Maria, Pereira de Godoy José

    2011-11-01

    Thermotherapy has been indicated by some researchers as a treatment for lymphedema. A study comparing temperatures demonstrated that a temperature of 40°C significantly increased the transportation of lymph compared to other temperatures assessed. The aim of this study was to evaluate the possible benefits of mechanical lymph drainage accompanied with heat in the treatment of lymphedema of the lower limbs. In a cross-over randomized study, the effect of heat on lymph drainage was evaluated in the treatment of leg lymphedema. The study, performed in the Godoy Clinic in São Jose do Rio Preto, Brazil, involved seven patients (two males and five females) with leg lymphedema. The patients' ages ranged from 18 to 79 years old with a mean of 48.5 years. The subjects underwent a total of 38 assessments including 19 evaluations of mechanical lymph drainage alone and 19 combined with thermotherapy. Heat was applied using an electric blanket which was wrapped around the legs of the patients. The volume of legs was evaluated by water plethysmography before and after treatment sessions. The paired t-test was used for statistical analysis with an alpha error of p = 0.05 being considered as acceptable. No statistically significant differences were evidenced between mechanical lymph drainage alone and lymph drainage combined with thermotherapy. There was no obvious synergic effect in the immediate post-treatment period when heat was combined with mechanical lymph drainage in the treatment of lymphedema.

  19. Estimation of Tile Drainage Contribution to Streamflow and Nutrient Export Loads

    Science.gov (United States)

    Schilling, K. E.; Arenas Amado, A.; Jones, C. S.; Weber, L. J.

    2015-12-01

    Subsurface drainage is a very common practice in the agricultural U.S. Midwest. It is typically installed in poorly drained soils in order to enhance crop yields. The presence of tile drains creates a route for agrichemicals to travel and therefore negatively impacts stream water quality. This study estimated through end-member analyses the contributions of tile drainage, groundwater, and surface runoff to streamflow at the watershed scale based on continuously monitored data. Especial attention was devoted to quantifying tile drainage impact on watershed streamflow and nutrient export loads. Data analyzed includes streamflow, rainfall, soil moisture, shallow groundwater levels, in-stream nitrate+nitrite concentrations and specific conductance. Data were collected at a HUC12 watershed located in Northeast Iowa, USA. Approximately 60% of the total watershed area is devoted to agricultural activities and forest and grassland are the other two predominant land uses. Results show that approximately 20% of total annual streamflow comes from tile drainage and during rainfall events tile drainage contribution can go up to 30%. Furthermore, for most of the analyzed rainfall events groundwater responded faster and in a more dramatic fashion than tile drainage. The State of Iowa is currently carrying out a plan to reduce nutrients in Iowa waters and the Gulf of Mexico (Iowa Nutrient Reduction Strategy). The outcome of this investigation has the potential to assist in Best Management Practice (BMP) scenario selection and therefore help the state achieve water quality goals.

  20. Ultrasound-guided endocavitary drainage of pelvic abscesses: Technique, results and complications

    International Nuclear Information System (INIS)

    Ryan, R.S.; McGrath, F P.; Haslam, P.J.; Varghese, J.C.; Lee, M.J.

    2003-01-01

    AIM: To evaluate the experience in our institution with ultrasound-guided transrectal and transvaginal (endocavitary) drainage of pelvic abscesses. MATERIALS AND METHODS: Eighteen patients (four male, 14 female; mean age 55 years, range 30-78 years) presenting with pelvic abscesses were referred to our institution for therapeutic drainage over a 4 year period. Patients received broad-spectrum antibiotics prior to drainage, which was performed by either the transvaginal or transrectal route under ultrasound guidance. Patients were given sedo-analgesia in the form of midazolam and fentanyl and local anaesthesia was also employed. Eight French catheters were inserted into the abscess cavities, and patients were subsequently monitored on a daily basis by a member of the interventional radiology team until such time as it was deemed appropriate to remove the catheter. RESULTS: Eighteen catheters were placed in 17 patients, and transvaginal aspiration alone was performed in one patient. Drainage was successful in 16 of 17 patients, but a transgluteal approach was ultimately required in the remaining patient to enable passage of a larger catheter into an infected haematoma. The mean duration of drainage was 5 days, mean time to defervesce 2 days. Spontaneous catheter dislodgement occurred in four patients associated with straining, but this did not have any adverse effect in three of the four patients. CONCLUSION: Endocavitary drainage is an effective method of treatment for pelvic abscesses. Spontaneous catheter dislodgement does not affect patient outcome

  1. Ultrasound-guided endocavitary drainage of pelvic abscesses: Technique, results and complications

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, R.S.; McGrath, F P.; Haslam, P.J.; Varghese, J.C.; Lee, M.J

    2003-01-01

    AIM: To evaluate the experience in our institution with ultrasound-guided transrectal and transvaginal (endocavitary) drainage of pelvic abscesses. MATERIALS AND METHODS: Eighteen patients (four male, 14 female; mean age 55 years, range 30-78 years) presenting with pelvic abscesses were referred to our institution for therapeutic drainage over a 4 year period. Patients received broad-spectrum antibiotics prior to drainage, which was performed by either the transvaginal or transrectal route under ultrasound guidance. Patients were given sedo-analgesia in the form of midazolam and fentanyl and local anaesthesia was also employed. Eight French catheters were inserted into the abscess cavities, and patients were subsequently monitored on a daily basis by a member of the interventional radiology team until such time as it was deemed appropriate to remove the catheter. RESULTS: Eighteen catheters were placed in 17 patients, and transvaginal aspiration alone was performed in one patient. Drainage was successful in 16 of 17 patients, but a transgluteal approach was ultimately required in the remaining patient to enable passage of a larger catheter into an infected haematoma. The mean duration of drainage was 5 days, mean time to defervesce 2 days. Spontaneous catheter dislodgement occurred in four patients associated with straining, but this did not have any adverse effect in three of the four patients. CONCLUSION: Endocavitary drainage is an effective method of treatment for pelvic abscesses. Spontaneous catheter dislodgement does not affect patient outcome.

  2. Flow and geochemical modeling of drainage from Tomitaka mine, Miyazaki, Japan.

    Science.gov (United States)

    Yamaguchi, Kohei; Tomiyama, Shingo; Metugi, Hideya; Ii, Hiroyuki; Ueda, Akira

    2015-10-01

    The chemistry and flow of water in the abandoned Tomitaka mine of Miyazaki, western Japan were investigated. This mine is located in a non-ferrous metal deposit and acid mine drainage issues from it. The study was undertaken to estimate the quantities of mine drainage that needs to be treated in order to avoid acidification of local rivers, taking into account seasonal variations in rainfall. Numerical models aimed to reproduce observed water levels and fluxes and chemical variations of groundwater and mine drainage. Rock-water interactions that may explain the observed variations in water chemistry are proposed. The results show that: (1) rain water infiltrates into the deeper bedrock through a highly permeable zone formed largely by stopes that are partially filled with spoil from excavations (ore minerals and host rocks); (2) the water becomes acidic (pH from 3 to 4) as dissolved oxygen oxidizes pyrite; (3) along the flow path through the rocks, the redox potential of the water becomes reducing, such that pyrite becomes stable and pH of the mine drainage becomes neutral; and (4) upon leaving the mine, the drainage becomes acidic again due to oxidation of pyrite in the rocks. The present numerical model with considering of the geochemical characteristics can simulate the main variations in groundwater flow and water levels in and around the Tomitaka mine, and apply to the future treatment of the mine drainage. Copyright © 2015. Published by Elsevier B.V.

  3. Urban drainage models simplifying uncertainty analysis for practitioners

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Mikkelsen, Peter Steen; Deletic, Ana

    2013-01-01

    in each measured/observed datapoint; an issue that is commonly overlooked in the uncertainty analysis of urban drainage models. This comparison allows the user to intuitively estimate the optimum number of simulations required to conduct uncertainty analyses. The output of the method includes parameter......There is increasing awareness about uncertainties in the modelling of urban drainage systems and, as such, many new methods for uncertainty analyses have been developed. Despite this, all available methods have limitations which restrict their widespread application among practitioners. Here...

  4. Outline of laundry drainage treatment system combining catalytic oxidation and filtration

    International Nuclear Information System (INIS)

    Kanda, Masanori; Matsuzaki, Susumu; Kikkawa, Ryouzo; Masuda, Kazumichi; Takeuchi, Kimihito; Urabe, Osamu

    2011-01-01

    We plan to use a laundry drainage treatment system that combines a device using a manganese dioxide-based catalyst for ozone oxidation with a ceramic microfiltration membrane (MF membrane). The high oxidizing power of ozone is enhanced by the catalyst, and the impurities (such as chemical oxygen demand (COD) causative substances and n-hexane extracts) in the drainage are sufficiently degraded to allow their releases to the environment. Ionic nuclides are also oxidized and in solubilized so that they can be separated with the MF membrane having fine pores of about 0.1 μm. The performance of the treatment system in removing radioactivity, COD causative substances, and n-hexane extracts was confirmed by hot demonstration tests using actual laundry drainage. Cold tests were also conducted using simulated laundry drainage to confirm the system operation conditions and the long-term stability of drainage treatment capability. While ozone has a high oxidizing power, it decays spontaneously in liquid within a short period of time. Therefore, the behavior of ozone under the operating conditions and its effect on the corrosion of structural materials were investigated to maintain a sufficient time for decay and select appropriate structural materials. (author)

  5. Basics of Postural Drainage and Percussion

    Science.gov (United States)

    ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... care. Clinician Awards Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: ...

  6. AUTOMATIC GENERALIZABILITY METHOD OF URBAN DRAINAGE PIPE NETWORK CONSIDERING MULTI-FEATURES

    Directory of Open Access Journals (Sweden)

    S. Zhu

    2018-05-01

    Full Text Available Urban drainage systems are indispensable dataset for storm-flooding simulation. Given data availability and current computing power, the structure and complexity of urban drainage systems require to be simplify. However, till data, the simplify procedure mainly depend on manual operation that always leads to mistakes and lower work efficiency. This work referenced the classification methodology of road system, and proposed a conception of pipeline stroke. Further, length of pipeline, angle between two pipelines, the pipeline belonged road level and diameter of pipeline were chosen as the similarity criterion to generate the pipeline stroke. Finally, designed the automatic method to generalize drainage systems with the concern of multi-features. This technique can improve the efficiency and accuracy of the generalization of drainage systems. In addition, it is beneficial to the study of urban storm-floods.

  7. Effect of subsurface drainage on salt movement and distribution in salt-affected soils

    International Nuclear Information System (INIS)

    Moustafa, A.T.A.; Seliem, M.H.; Bakhati, H.K.

    1983-01-01

    This study was carried out to evaluate different subsurface drainage treatments (combinations of depth and spacing) on salt movement and distribution. The soil is clay and the drainage was designed according to the steady-state condition (Hooghoudt's equation). Three spacings and two depths resulted in six drainage treatments. Soil samples represented the initial state of every treatment and after 14 months they (cotton followed by wheat) were analysed. The data show that drain depth has its effective role in salt leaching, while drain spacing has its effect on salt distribution in the soil profile. The leaching rate of each specific ion is also affected by the different drainage treatments. In general, the salt movement and distribution should be taken into consideration when evaluating the design of drainage systems. (author)

  8. Aspects to consider for optimizing a substrate culture system with drainage recycling

    Directory of Open Access Journals (Sweden)

    William J Cuervo B

    2012-09-01

    Full Text Available In Colombia, the soilless system has been implemented in the cut flowers industry, among others, due to soil limitations. The use of substrates as growing media implies to drain around 30% of the applied fertigation solution to avoid the rhizosphere salinization. The drainage solution is spilled out to the soil producing environmental hazards and it might reach the water table; although the drainage solution could be recycled or reuse, depending upon their chemical characteristics. The nutrient uptake by the plants depends upon their phenological stage and the nutrient concentration in the solution; which could lead to ion depletion or accumulation. In general, monovalent ions are withdrawn faster than divalent ones. An efficient drainage treatment involves the automation of sensing and evaluation of ion concentration and recycling the drainage solution. The system should take into account the chemical aspects in the recycled and the new solutions in order to predict the life time of the drainage solution from their EC and pH. The system must be integrated with disinfection methods to avoid the spreading of plant pathogens. This review point out the physiological and technical bases that should be taking into account in a drainage recycling system in established crops under substrates, as a tool to take decisions more efficiently.

  9. On the development of the system of risk-based supervision in the field of sanitary and epidemiological welfare of the population and consumer protection

    Directory of Open Access Journals (Sweden)

    A.Y. Popova

    2015-12-01

    Full Text Available In order to fulfill the legal requirements for the transition to the new risk-based model of the state control (supervision in the Federal Service for Consumer Rights Protection and Human Welfare, the methodical approaches to the classification of economic entities and activities of potential risk of injury have been developed. The risk assessment takes into account the frequency of violations of sanitary legislation, the severity of the consequences of these violations for the health and extent of negative effects, which is estimated in terms of population under the influence of the economic entity. Algorithms and methods for calculating the exposed population: workers, consumers, including consumer food products, non-food products and services; residents of settlements under the negative impact of air pollution, water and soil, have been developed. Regional and federal registries of objects for sanitary and epidemiological supervision are formed. Testing of the risk-based approaches in the regions allowed excluding the low risk harm objects when forming the audit plans for 2016, due to what the number of planned inspections all over country was reduces by more than 20 %. The basic directions of further improvement of the risk-based model of sanitary and epidemiological surveillance: its extension to the system of technical regulation and consumer protection; scientific substantiation of its volume, content and laboratory support of the scheduled inspections of objects belonging to different classes of health risk; improving procedures and methods for evaluating the effectiveness and efficiency of risk-based supervisory activities; creation of an effective system of risk communication between the sanitary and epidemiological surveillance, economic entities, public organizations and associations and civil society.

  10. Preoperative Biliary Drainage for Cancer of the Head of the Pancreas

    NARCIS (Netherlands)

    van der Gaag, Niels A.; Rauws, Erik A. J.; van Eijck, Casper H. J.; Bruno, Marco J.; van der Harst, Erwin; Kubben, Frank J. G. M.; Gerritsen, Josephus J. G. M.; Greve, Jan Willem; Gerhards, Michael F.; de Hingh, Ignace H. J. T.; Klinkenbijl, Jean H.; Nio, Chung Y.; de Castro, Steve M. M.; Busch, Olivier R. C.; van Gulik, Thomas M.; Bossuyt, Patrick M. M.; Gouma, Dirk J.

    2010-01-01

    BACKGROUND The benefits of preoperative biliary drainage, which was introduced to improve the postoperative outcome in patients with obstructive jaundice caused by a tumor of the pancreatic head, are unclear. METHODS In this multicenter, randomized trial, we compared preoperative biliary drainage

  11. NPDES Permit for Leadville Mine Drainage Tunnel Treatment Plant in Colorado

    Science.gov (United States)

    Under NPDES permit CO-0021717, the U.S. Bureau of Reclamation is authorized to discharge from the Leadville Mine Drainage Tunnel Treatment Plant in Lake County, Colorado to an unnamed drainage way tributary to the East Fork of the Arkansas River.

  12. Percutaneous drainage of abscess in the treatment of emphysematous pyelonephritis

    International Nuclear Information System (INIS)

    Jung, Jin Yong; Jeong, Yong Yeon; Kim, Jae Kyu; Park, Seung Jei; Park, Jin Gyoon; Kang, Heoung Keun; Roh, Byung Suk

    1997-01-01

    To assess the usefulness of percutaneous drainage of abscess in the treatment of emphysematous pyelonephritis. Ten cases of nine patients with emphysematous pyelonephritis were percutaneously drained. All were suffering from diabetes mellitus. The procedure was performed under fluoroscopic guidance in nine cases and US guidance in one case in which bilateral multiloculated abscesses were present in the perirenal space. The results were classified as cure, partial success, recurrence, or failure. The mean drainage period and complication were analyzed. Eight cases were cured, and there was one case success. In one case, who had diffuse renal parenchymal destruction without perirenal fluid collection, the treatment failed. The longest drainage period was 45 days, in a case of re-insertion due to incidental catheter removal; the mean was 23 days. Bacteremia in one case was cured with antibiotic therapy which lasted two days. In diabetic patients, percutaneous drainage of obscess is thought to be a safe and effective method for the treatment of emphysematous pyelonephritis, and is one that does not involve diffuse destruction of renal parenchyma

  13. Extensive experimental investigation of the effect of drainage height and solvent type on the stabilized drainage rate in vapour extraction (VAPEX) process

    OpenAIRE

    Mehdi Mohammadpoor; Farshid Torabi

    2015-01-01

    The low cost of the injected solvent, which can be also recovered and recycled, and the applicability of VAPEX technique in thin reservoirs are among the main advantages of VAPEX process compared to thermal heavy oil recovery techniques. In this research, an extensive experimental investigation is carried out to first evaluate the technical feasibility of utilization of various solvents for VAPEX process. Then the effect of drainage height on the stabilized drainage rate in VAPEX process was ...

  14. SANITARY-HYGIENIC ASPECTS IN COMMERCIALIZATION IN FISH MARKET IGARAPÉ DAS MULHERES, MACAPÁ-AP

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Souza Silva Junior

    2016-12-01

    Full Text Available Being highly perishable, the fish requires special care from capture to arrival at the consumer's home. However, after the capture, the microbiota is altered at all stages. This study aimed to assess the sanitary conditions of marketing of fish in the Fish Friday, Macapá-AP, in order to identify critical points of the process. We used the direct observational method with the application of a checklist, based on the RDC nº216, items for building, equipment / instruments, utensils and hygiene, clothing, hygienic habits, personal protective equipment and quality raw material. The fair in question was rated in Group 2, failing to meet the requirements of industry topics Organization (marketing space extremely limited, national manager indefinite absence of good practice manual, along with the standard operating procedures; hygiene observation site (fish is exposed without ice, ice used only for storage, water use without treatment, and cleaned the handler (clothing unsatisfactory, tobacco consumption during marketing, simultaneous manipulation of money and food, no clean hands when handling food thus does not meet the provisions of the legislation. Such unconformities compromise the quality of products and endangers the health of the consumer, demonstrating that only the drafting of laws is not sufficient to ensure food safety without intense scrutiny in conjunction with the drafting resolutions appropriate to the reality of each region and training programs aimed at promoting recycling and the production of safe food hygiene and sanitary conditions in the question that reality cannot be changed. Keywords: marketing of fish; conditions of merchantability; market.

  15. Present and prospective developments in health science and sanitary supervision relative to use of atomic energy in national economy

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Mojsejtsev, P.I.; Vasil'ev, G.

    1977-01-01

    The discoveries and inventions made over the last two decades have substantially enlarged the scope of contacts between man and sources of ionizing radiation. Scientific developments raising energy yield from nuclear processes have been reflected in a growing nuclear power industry as well as expanding use of radioactive substances or radiation sources in various areas of human endeavor, and have become a potent factor in technological progress, mechanization and automation. No such tempestuous expansion of applications of nuclear physics achievements would have been possible without the concurrent development and further synchronous advances in relevant fields of health science, with research achievements promptly introduced into sanitary supervision practice. The paper summarizes major results of research in radiation hygiene; outlines the impact of their application to sanitary supervision practice in principal operational sectors; identifies and motivates further lines of injury as well as prospects for developing up-to-date supervision schemes and for reasonable unification of measurement and monitoring techniques. (author)

  16. Peritoneal seeding of cholangiocarcinoma in patients with percutaneous biliary drainage

    International Nuclear Information System (INIS)

    Miller, G.A. Jr.; Heaston, D.K.; Moore, A.V. Jr.; Mills, S.R.; Dunnick, N.R.

    1983-01-01

    Percutaneous transhepatic catheter decompression is performed increasingly as an adjunct or alternative to surgery in patients with benign or malignant biliary obstruction. The authors recently saw three patients with cholangiocarcinoma in whom metastatic seeding of the peritoneal serosa was identified some months after initial percutaneous transhepatic biliary drainage. Although no tumor was found along the hepatic tract of the biliary drainage catheters to implicate the drainage tubes as the direct source of peritoneal spread, the occurrence of this rare type of metastasis of cholangiocarcinoma in patients with potential access of tumor cells to the peritoneal cavity via the catheter tracts does suggest such a relation. The clinical history of one patient is presented

  17. in remediating acid mine drainage

    African Journals Online (AJOL)

    The management and treatment of contaminated mine water is one of the most urgent problems facing the South African mining industry. The cost advantage of permeable reactive barriers (PRBs) has seen their increased application as means of passively treating mine drainage. A PRB is built by placing a reactive material ...

  18. Long-Term Hydrologic Impacts of Controlled Drainage Using DRAINMOD

    Science.gov (United States)

    Saadat, S.; Bowling, L. C.; Frankenberger, J.

    2017-12-01

    Controlled drainage is a management strategy designed to mitigate water quality issues caused by subsurface drainage but it may increase surface ponding and runoff. To improve controlled drainage system management, a long-term and broader study is needed that goes beyond the experimental studies. Therefore, the goal of this study was to parametrize the DRAINMOD field-scale, hydrologic model for the Davis Purdue Agricultural Center located in Eastern Indiana and to predict the subsurface drain flow and surface runoff and ponding at this research site. The Green-Ampt equation was used to characterize the infiltration, and digital elevation models (DEMs) were used to estimate the maximum depressional storage as the surface ponding parameter inputs to DRAINMOD. Hydraulic conductivity was estimated using the Hooghoudt equation and the measured drain flow and water table depths. Other model inputs were either estimated or taken from the measurements. The DRAINMOD model was calibrated and validated by comparing model predictions of subsurface drainage and water table depths with field observations from 2012 to 2016. Simulations based on the DRAINMOD model can increase understanding of the environmental and hydrological effects over a broader temporal and spatial scale than is possible using field-scale data and this is useful for developing management recommendations for water resources at field and watershed scales.

  19. Process for integrating surface drainage constraints on mine planning

    Energy Technology Data Exchange (ETDEWEB)

    Sawatsky, L.F; Ade, F.L.; McDonald, D.M.; Pullman, B.J. [Golder Associates Ltd., Calgary, AB (Canada)

    2009-07-01

    Surface drainage for mine closures must be considered during all phases of mine planning and design in order to minimize environmental impacts and reduce costs. This paper discussed methods of integrating mine drainage criteria and associated mine planning constraints into the mine planning process. Drainage constraints included stream diversions; fish compensation channels; collection receptacles for the re-use of process water; separation of closed circuit water from fresh water; and the provision of storage ponds. The geomorphic approach replicated the ability of natural channels to respond to local and regional changes in hydrology as well as channel disturbances from extreme flood events, sedimentation, debris, ice jams, and beaver activity. The approach was designed to enable a sustainable system and provide conveyance capacity for extreme floods without spillage to adjacent watersheds. Channel dimensions, bank and bed materials, sediment loads, bed material supplies and the hydrologic conditions of the analogue stream were considered. Hydrologic analyses were conducted to determine design flood flow. Channel routes, valley slopes, sinuosity, width, and depth were established. It was concluded that by incorporating the geomorphic technique, mine operators and designers can construct self-sustaining drainage systems that require little or no maintenance in the long-term. 7 refs.

  20. Spontaneous drainage in syringomyelia: magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Bogdanov, E.I.; Mendelevich, E.G.; Ibatullin, M.M.

    2000-01-01

    We present five cases of syringomyelia associated with Chiari I or other causes of partial obstructions at the cervicomedullary junction, with spontaneous disruption of the wall of a cervical syrinx and formation of a communication between the cavity and the subarachnoid space, shown on axial MRI. MRI can be used to investigate the hydrodynamics, showing the liquid inside the disrupted syrinx wall and the pathway of drainage. The finding of spontaneous drainage may be important for understanding the pathogenesis of syringomyelia and may be helpful for choosing a surgical approach. (orig.)