WorldWideScience

Sample records for drain line leakage

  1. Shearon Harris steam generator channel head drain line leakage

    International Nuclear Information System (INIS)

    Bauer, P.A.

    1992-01-01

    All three Shearon Harris steam generators were equipped with Inconel 600 drain penetrations inserted into clearance holes on the bottom center line of the plenums, roll expanded into the plenum shell, and seal welded to the stainless steel cladding. Eddy current inspections showed axial cracks in the drain lines of B and C generators, but not on the leaking A generator. The drain lines of the three generators were repaired by cutting off the pipe under the plenum, applying Inconel 600 cladding to the underside of the plenum by a temper bead process, spot facing the overlay cladding and welding a new Inconel 600 pipe coupling to the clad surface. 3 figs

  2. Microdose Induced Drain Leakage Effects in Power Trench MOSFETs: Experiment and Modeling

    Science.gov (United States)

    Zebrev, Gennady I.; Vatuev, Alexander S.; Useinov, Rustem G.; Emeliyanov, Vladimir V.; Anashin, Vasily S.; Gorbunov, Maxim S.; Turin, Valentin O.; Yesenkov, Kirill A.

    2014-08-01

    We study experimentally and theoretically the micro-dose induced drain-source leakage current in the trench power MOSFETs under irradiation with high-LET heavy ions. We found experimentally that cumulative increase of leakage current occurs by means of stochastic spikes corresponding to a strike of single heavy ion into the MOSFET gate oxide. We simulate this effect with the proposed analytic model allowing to describe (including Monte Carlo methods) both the deterministic (cumulative dose) and stochastic (single event) aspects of the problem. Based on this model the survival probability assessment in space heavy ion environment with high LETs was proposed.

  3. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    International Nuclear Information System (INIS)

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.; Joslyn, Cameron C.; Vazquez, Brandon J.; Venetz, Theodore J.; Garfield, John S.

    2014-01-01

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line

  4. Endoscopic Management of Drain Inclusion in the Gastric Pouch after Gastrojejunal Leakage after Laparoscopic Roux-en-Y Gastric Bypass for the Treatment of Morbid Obesity (LRYGBP

    Directory of Open Access Journals (Sweden)

    Ramon Vilallonga

    2010-01-01

    Patients. All four obese morbidly patients underwent LRYGBP and presented a gastro-jejunal fistula after acute anastomotic leakage. During follow-up endoscopy the drain was found inside the gastric pouch. It was moved into the abdominal cavity. Fistula debit reduced significantly and closed. Results. Gastric leak closure in less than 24 hours was achieved in all, with complete resolution of symptoms. These patients benefited exclusively from endoscopic treatment. Conclusions. Endoscopy is useful and technically feasible in chronic fistulas. This procedure is a less invasive alternative to traditional surgical revision. Other therapeutic strategies can be used such as clips and fibrin glue. Drains should not be placed in contact with the anastomosis or stapled lines. Drain inclusion must be suspected when fistula debit suddenly arises. If so, endoscopy is indicated for diagnostic accuracy. Under endoscopy vision, the drain is gently removed from the gastric reservoir leading to sudden and complete resolution of the fistula.

  5. A novel transanal tube designed to prevent anastomotic leakage after rectal cancer surgery: the WING DRAIN.

    Science.gov (United States)

    Nishigori, Hideaki; Ito, Masaaki; Nishizawa, Yuji

    2017-04-01

    We introduce a novel transanal tube (TAT), named the "WING DRAIN", designed to prevent anastomotic leakage after rectal cancer surgery, and report the fundamental experiments that led to its development. We performed the basic experiments to evaluate the effect of TATs on intestinal decompression, the changes they make in patterns of watery fluid drainage, the changes in their decompression effect when the extension tube connecting the TAT to the collection bag fills with watery drainage fluid, and the variations in intestinal contact and crushing pressure made by some types of TAT. Any type of TAT contributed to decompression in the intestinal tract. Watery drainage commenced from when the water level first rose to the hole in the tip of drain. The intestinal pressure increased with the length of the vertical twist in an extension tube. The crushing pressures of most types of TAT were high enough to cause injury to the intestine. We resolved the problems using an existing TAT for the purpose of intestinal decompression and by creating the first specialized TAT designed to prevent anastomotic leakage after rectal cancer surgery in Japan.

  6. Draining Collars and Lenses in Liquid-Lined Vertical Tubes.

    Science.gov (United States)

    Jensen

    2000-01-01

    The speed at which an annular liquid collar drains under gravity g in a vertical tube of radius a, when the tube has an otherwise thin viscous liquid lining on its interior, is determined by a balance between the collar's weight and viscous shear stresses confined to narrow regions in the neighborhood of the collar's effective contact lines. Whether a collar grows or shrinks in volume as it drains depends on the modified Bond number B=rho g a(2)/(sigmaepsilon), where rho is the fluid density, sigma is its surface tension, and epsilona is the thickness of the thin film immediately ahead of the collar. Asymptotic methods are used here to determine the following nonlinear stability criteria for an individual collar, valid in the limit of small epsilon. For 0draining collars grow in volume and, in sufficiently long tubes, ultimately "snap off" to form stable lenses. For 0.5960drain, so that any lens ultimately ruptures, unless stabilizing intermolecular forces allow the formation of a lamella supported by a macroscopic Plateau border. If surfactant immobilizes the liquid's free surface, these critical values of B are reduced by a factor of 2 but the distance a collar must travel before it snaps off is unchanged. Gravitationally driven snap off is therefore most likely to occur in long tubes with radii substantially less than the capillary lengthscale sigma/rhog)(1/2). Copyright 2000 Academic Press.

  7. Characterization Plan for Soils Around Drain Line PLA-100115

    Energy Technology Data Exchange (ETDEWEB)

    D. Shanklin

    2006-05-24

    This Characterization Plan supports the Hazardous Waste Management Act/Resource Conservation and Recovery Act (HWMA/RCRA) closure of soils that may have been contaminated by releases from drain line PLA-100115, located within the Idaho Nuclear Technology and Engineering Center at the Idaho National Laboratory Site. The requirements to address the closure of soils contaminated by a potential release from this line in a characterization plan was identified in the "HWMA/RCRA Less Than 90-day Generator Closure Report for the VES-SFE-126."

  8. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  9. Reverse airflow in certain chest drains may be misinterpreted as prolonged air leakage

    DEFF Research Database (Denmark)

    Stouby, Anna; Neckelmann, Kirsten; Licht, Peter B

    2011-01-01

    Prolonged air leakage is common after lung resection. We observed that during deep inspiration some patients were able to empty the water-seal of commercial chest drainage systems and retract air back into the chest tube, which subsequently escaped during the following expiration, mimicking "true...

  10. Evaluation of Persistent Lymphatic Fluid Leakage Using a Strategy of Placing a Drain After Kidney Transplantation: A Statistical Analysis to Assess Its Origin.

    Science.gov (United States)

    Inoue, T; Saito, M; Narita, S; Numakura, K; Tsuruta, H; Maeno, A; Tsuchiya, N; Satoh, S; Habuchi, T

    2017-10-01

    Using a strategy of placing a surgical drain after kidney transplantation, the duration of a lymphatic fluid leakage and prevalence of a symptomatic lymphocele were retrospectively analyzed. The risk factors for persistent lymphatic fluid leakage or asymptomatic lymphocele were evaluated using multivariate analysis to estimate the origin of the lymphatic fluid leakage. Patients with persistent lymphatic fluid leakage and symptomatic lymphocele were defined as those with lymphatic fluid drainage >50 mL for more than 15 days and those who required a percutaneous drainage of the lymphocele, respectively. Persistent lymphatic fluid leakage and symptomatic lymphocele were observed in 40 (16.4%) and 10 (4.1%) of a total of 244 patients, respectively. The maximum durations of lymphatic fluid drainage from the initial drain tube and the second drainage of the symptomatic lymphocele were 48 and 28 days, respectively. Anastomosis of the graft artery to the external iliac artery was an independent risk factor to predict persistent lymphatic fluid leakage or symptomatic lymphocele after kidney transplantation (odds = 2.597, P = .008). The findings of the study suggest that the lymphatic fluid originates from the recipient's iliac lymph trunk rather than from the graft kidney. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Characterizing subsurface water flow to artificial drain lines using fiber-optic distributed temperature sensing

    Science.gov (United States)

    Shults, D.; Brooks, E. S.; Heinse, R.; Keller, C. K.

    2017-12-01

    Over the last several years growers have experienced increasingly wet spring conditions in the Palouse Region located in North Idaho, Eastern Washington and Eastern Oregon. As a result more artificial drain lines are being installed so growers can access their fields earlier in the growing season. Additionally there has been increasing adoption of no-tillage practices among growers in order minimize erosion and runoff in the region. There is a growing body of evidence that suggests long-term no-tillage may lead to the establishment of large macropore networks through increased earthworm activity and the preservation of root channels. These macropore networks, in conjunctions with the presence of artificial drains lines, may create connected preferential flow paths from agricultural fields to receiving streams. This connectivity of flow paths from agricultural fields to receiving water bodies may increase the loading of nutrients and agricultural chemicals as some flow paths may largely bypass soil matrix interaction where materials can be sequestered. Our primary objective for this study was to characterize subsurface flow to two artificial drain lines, one under conventional tillage and the other under no-tillage, using distributed temperature sensing (DTS) technology. During the study (November 2016-April 2017) the near surface soil-water temperature was consistently colder than that of deeper depths. Temperature was thus used as a tracer as snow melt and soil-water moved from the near surface to the drain lines during snowmelt and precipitation events. The spatial and temporal variability of the temperature along the artificial drain line under no-tillage practices was found to be greater than that of the conventional tilled field. It is hypothesized that preferential flow paths are responsible for the increased variability of temperature seen in the drain line under long term no-till management. The temperature along the conventional till drain line showed a

  12. A new on-line leakage current monitoring system of ZnO surge arresters

    International Nuclear Information System (INIS)

    Lee, Bok-Hee; Kang, Sung-Man

    2005-01-01

    This paper presents a new on-line leakage current monitoring system of zinc oxide (ZnO) surge arresters. To effectively diagnose the deterioration of ZnO surge arresters, a new algorithm and on-line leakage current detection device, which uses the time-delay addition method, for discriminating the resistive and capacitive currents was developed to use in the aging test and durability evaluation for ZnO arrester blocks. A computer-based measurement system of the resistive leakage current, the on-line monitoring device can detect accurately the leakage currents flowing through ZnO surge arresters for power frequency ac applied voltages. The proposed on-line leakage current monitoring device of ZnO surge arresters is more highly sensitive and gives more linear response than the existing devices using the detection method of the third harmonic leakage currents. Therefore, the proposed leakage current monitoring device can be useful for predicting the defects and performance deterioration of ZnO surge arresters in power system applications

  13. Simulation and experimental research of heat leakage of cryogenic transfer lines

    Science.gov (United States)

    Deng, B. C.; Xie, X. J.; Pan, W.; Jiang, R. X.; Li, J.; Yang, S. Q.; Li, Q.

    2017-12-01

    The heat leakage of cryogenic transfer lines directly influences the performance of large-scale helium refrigerator. In this paper, a thermal model of cryogenic transfer line considering numerical simulation of support coupled with MLI was established. To validate the model, test platform of cryogenic transfer lines with the merits of disassembly outer pipe and changeable easily multi-layer insulation has been built. The experimental results of heat leakage through overall length of cryogenic transfer lines, support and multi-layer insulation were obtained. The heat leakages of multi-layer insulation, a support and the overall leakage are 1.02 W/m, 0.44 W and 1.46 W/m from experimental data, respectively. The difference of heat leakage of MLI between experiment and simulation were less than 5%. The temperature distribution of support and MLI obtained in presented model in good agreement with experimental data. It is expected to reduce the overall heat leakage of cryogenic transfer lines further by optimizing structure of support based on the above thermal model and test platform in this paper.

  14. X-ray K-edge analysis of drain lines in Wilhelm Hall, Ames Laboratory

    International Nuclear Information System (INIS)

    Jensen, T.; Whitmore, C.; Iowa State Univ., Ames, IA

    1999-01-01

    From August 12--27, 1998 X-ray K-edge measurements were made on drain lines in seven rooms in Wilhelm Hall, Ames Laboratory. The purpose of these measurements was to determine the extent of thorium (and other heavy metal) contamination inside these pipes. The K-edge method is a noninvasive inspection technique that can provide accurate quantification of heavy metal contamination interior to an object. Of the seven drain lines inspected, one was found to have no significant contamination, three showed significant thorium deposits, two showed mercury contamination, and one line was found to contain mercury, thorium and uranium. The K-edge measurements were found to be consistent with readings from hand-held survey meters, and provided much greater detail on the location and amount of heavy metal contamination

  15. Effects of trap-assisted tunneling on gate-induced drain leakage in silicon-germanium channel p-type FET for scaled supply voltages

    Science.gov (United States)

    Tiwari, Vishal A.; Divakaruni, Rama; Hook, Terence B.; Nair, Deleep R.

    2016-04-01

    Silicon-germanium is considered as an alternative channel material to silicon p-type FET (pFET) for the development of energy efficient high performance transistors for 28 nm and beyond in a high-k metal gate technology because of its lower threshold voltage and higher mobility. However, gate-induced drain leakage (GIDL) is a concern for high threshold voltage device design because of tunneling at reduced bandgap. In this work, the trap-assisted tunneling and band-to-band tunneling (BTBT) effects on GIDL is analyzed and modeled for SiGe pFETs. Experimental results and Monte Carlo simulation results reveal that the pre-halo germanium pre-amorphization implant used to contain the short channel effects contribute to GIDL at the drain sidewall in addition to GIDL due to BTBT in SiGe devices. The results are validated by comparing the experimental observations with the numerical simulation and a set of calibrated models are used to describe the GIDL mechanisms for various drain and gate bias.

  16. Use of coliform bacteria for the detection of on-line leakage in drinking water

    International Nuclear Information System (INIS)

    Bibi, S.; Karim, H.M.A.; Mashiatullah, A.; Sajjad, I.

    1996-01-01

    In this method, rupture or leakage in under ground water pipes is detected simply by taking the water samples from the main supply lines of the houses and incubating them at 40 deg. C for sixteen hours, colonies (developed with yellow colour) are counted with colony counter. Thirteen samples (in triplicate) collected from different houses in the congested localities during repair work of the major supply line and all of them after test showed heavy rate of pollution. The experiment was repeated for the same locality and sampling sites after completion of repair work. This time the rate of pollution decreases very much showing drastically low growth of microorganisms except for two points. For two further investigation of the nearly leakages at these points, 13 samples (in triplicate) were again collected in serial wise number of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of he pipes. This method is useful and causes no health hazard to the population and gives best results where the water supply is on intermittent basis. The technique is specially useful in the remote areas of the country where research facilities are not available and the Pacqualab is a field instrument. So it is handy and rapid method for the detection of leakage in underground water supplies in the remote areas of the country. (author)

  17. The removal of blockage from a BWR bottom head drain line

    International Nuclear Information System (INIS)

    McGough, M.S.

    1990-01-01

    Low flow through the 2-inch schedule 160 bottom head drain line at Carolina Power and Light's Brunswick Unit 2 indicated that the line was probably plugged. Since this low flow condition had existed since startup, it was suspected that the plug consisted of construction debris. However, the makeup of the plug was unknown, and the suspected location was inaccessible for nondestructive examination techniques. Evaluation of techniques possible, both from the vessel ID and from outside the vessel resulted in the selection of a hot-tapping device and a self-propelled high-pressure water lance which was inserted in the trapped line from the undervessel area. Removal of the plug was complicated by undervessel space restrictions, dose rates, and the torturous path of elbows and horizontal and vertical pipe runs which had to be negotiated with the water lance. This paper describes the technique applied to this problem

  18. Design of modified annulus air sampling system for the detection of leakage in waste transfer line

    International Nuclear Information System (INIS)

    Deokar, U.V; Khot, A.R.; Mathew, P.; Ganesh, G.; Tripathi, R.M.; Srivastava, Srishti

    2018-01-01

    Various liquid waste streams are generated during the operation of reprocessing plant. The High Level (HL), Intermediate Level (IL) and Low Level (LL) liquid wastes generated, are transferred from reprocessing plant to Waste Management Facility. These respective waste streams are transferred through pipe-in-pipe lines along the shielded concrete trench. For detection of radioactive leakage from primary waste transfer line into secondary line, sampling of the annulus air between the two pipes is carried out. The currently installed pressurized annulus air sampling system did not have online leakage detection provision. Hence, there are chances of personal exposure and airborne activity in the working area. To overcome these design flaws, free air flow modified online annulus air sampling system with more safety features is designed

  19. Determination of the crystalline structure of scale solids from the 16H evaporator gravity drain line to tank 38H

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-01

    August 2015, scale solids from the 16H Evaporator Gravity Drain Line (GDL) to the Tank 38H were delivered to SRNL for analysis. The desired analytical goal was to identify and confirm the crystalline structure of the scale material and determine if the form of the aluminosilicate mineral was consistent with previous analysis of the scale material from the GDL.

  20. Characterization of pipes, drain lines, and ducts using the pipe explorer system

    International Nuclear Information System (INIS)

    Cremer, C.D.; Kendrick, D.T.; Cramer, E.

    1997-01-01

    As DOE dismantles its nuclear processing facilities, site managers must employ the best means of disposing or remediating hundreds of miles of potentially contaminated piping and duct work. Their interiors are difficult to access, and in many cases even the exteriors are inaccessible. Without adequate characterization, it must be assumed that the piping is contaminated, and the disposal cost of buried drain lines can be on the order of $1,200/ft and is often unnecessary as residual contamination levels often are below free release criteria. This paper describes the program to develop a solution to the problem of characterizing radioactive contamination in pipes. The technical approach and results of using the Pipe Explorer trademark system are presented. The heart of the system is SEA's pressurized inverting membrane adapted to transport radiation detectors and other tools into pipes. It offers many benefits over other pipe inspection approaches. It has video and beta/gamma detection capabilities, and the need for alpha detection has been addressed through the development of the Alpha Explorer trademark. These systems have been used during various stages of decontamination and decommissioning of DOE sites, including the ANL CP-5 reactor D ampersand D. Future improvements and extensions of their capabilities are discussed

  1. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    Directory of Open Access Journals (Sweden)

    S. Zohar

    2016-09-01

    Full Text Available Small x-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation x-ray beamlines is the slow detuning of x-ray optics to marginal alignment where the onset of clipping increases the beam’s susceptibility to higher frequency position oscillations. In this article, we show that a 1  μm amplitude horizontal x-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  2. Turbulent penetration in T-junction branch lines with leakage flow

    Energy Technology Data Exchange (ETDEWEB)

    Kickhofel, John, E-mail: kickhofel@lke.mavt.ethz.ch; Valori, Valentina, E-mail: v.valori@tudelft.nl; Prasser, H.-M., E-mail: prasser@lke.mavt.ethz.ch

    2014-09-15

    Highlights: • New T-junction facility designed for adiabatic high velocity ratio mixing studies. • Trends in scalar mixing RMS and average in branch line presented and discussed. • Turbulent penetration has unique power spectrum relevant to thermal fatigue. • Forced flow oscillations translate to peaks in power spectrum in branch line. - Abstract: While the study of T-junction mixing with branch velocity ratios of near 1, so called cross flow mixing, is well advanced, to the point of realistic reactor environment fluid–structure interaction experiments and CFD benchmarking, turbulent penetration studies remain an under-researched threat to primary circuit piping. A new facility has been constructed for the express purpose of studying turbulent penetration in branch lines of T-junctions in the context of the high cycle thermal fatigue problem in NPPs. Turbulent penetration, which may be the result of a leaking valve in a branch line or an unisolable branch with heat losses, induces a thermal cycling region which may result in high cycle fatigue damage and failures. Leakage flow experiments have been performed in a perpendicular T-junction in a horizontal orientation with 50 mm diameter main pipe and branch pipe at velocity ratios (main/branch) up to 400. Wire mesh sensors are used as a means of measuring the mixing scalar in adiabatic tests with deionized and tap water. The near-wall region of highest scalar fluctuations is seen to vary circumferentially and in depth in the branch a great deal depending on the velocity ratio. The power spectra of the mixing scalar in the region of turbulent penetration are found to be dominated by high amplitude fluctuations at low frequencies, of particular interest to thermal fatigue. Artificial velocity oscillations in the main pipe manifest in the mixing spectra in the branch line in the form of a peak, the magnitude of which grows with increasing local RMS.

  3. Leakage characterization of top select transistor for program disturbance optimization in 3D NAND flash

    Science.gov (United States)

    Zhang, Yu; Jin, Lei; Jiang, Dandan; Zou, Xingqi; Zhao, Zhiguo; Gao, Jing; Zeng, Ming; Zhou, Wenbin; Tang, Zhaoyun; Huo, Zongliang

    2018-03-01

    In order to optimize program disturbance characteristics effectively, a characterization approach that measures top select transistor (TSG) leakage from bit-line is proposed to quantify TSG leakage under program inhibit condition in 3D NAND flash memory. Based on this approach, the effect of Vth modulation of two-cell TSG on leakage is evaluated. By checking the dependence of leakage and corresponding program disturbance on upper and lower TSG Vth, this approach is validated. The optimal Vth pattern with high upper TSG Vth and low lower TSG Vth has been suggested for low leakage current and high boosted channel potential. It is found that upper TSG plays dominant role in preventing drain induced barrier lowering (DIBL) leakage from boosted channel to bit-line, while lower TSG assists to further suppress TSG leakage by providing smooth potential drop from dummy WL to edge of TSG, consequently suppressing trap assisted band-to-band tunneling current (BTBT) between dummy WL and TSG.

  4. Calibration curves for on-line leakage detection using radiotracer injection method

    Directory of Open Access Journals (Sweden)

    Ayoub Khatooni

    2017-11-01

    Full Text Available One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl detectors which were located before and after the considered position, measure emitted gamma from radioactive tracer. After calibration of radiation detectors, the amount of leakage can be calculated based on the count difference of detectors. Also, the effect of material and thickness and diameter of pipe, crystal dimension, types of fluid, activity of tracer and its type (24Na, 82Br, 131I, 99mTc, 113mIn as well as have been investigated on the detectable amount of leakage. According to the results, for example, leakage more than 0.007% in volume of the inlet fluid for iron pipe with outer diameter 4 inch and thickness of 0.5 cm, Petrol as fluid inside pipe, 3 3 inch detector and 24Na with activity of 100 mCi can be detected by this presented method.

  5. [Diagnostic value of dynamic monitoring of C-reactive protein in drain drainage to predict early anastomotic leakage after colorectal cancer surgery].

    Science.gov (United States)

    Lu, Jia; Zheng, Lei; Li, Runtian; Hao, Chunmin; Gao, Wenbin; Feng, Ziwei; Yin, Guangya; Wang, Yue

    2017-09-25

    To evaluate the diagnostic value of dynamic monitoring of C-reactive protein (CRP) in drainage fluid in predicting early anastomotic leakage after colorectal surgery. This study enrolled 172 patients, who were diagnosed as colorectal cancer before operation and underwent radical surgery, without residual tumor tissues by postoperative pathology and perioperative infection, at the Tianjin Medical University Cancer Hospital between July 2015 and January 2016. The C-reactive(CRP) protein level in drainage fluid was continuously monitored from postoperative days (POD) 1 to 5. CRP level was compared between anastomotic leakage (AL) group and non-anastomotic leakage (NAL) group. Receiver operating characteristics (ROC) curve was used to estimate the value of monitoring CRP in drainage fluid to predict anastomotic leakage after colorectal surgery. Among 172 patients, 101 cases were male and 71 cases were female, with age of (59.9±10.3) years. Anastomotic leakage occurred after colorectal surgery in 24 cases(14.0%, AL group ) and other 148 cases were defined as NAL group. Other than body mass index (BMI), differences in baseline data were not statistically significant between two groups. The CRP lever in AL group and NAL group showed rising trend from POD1 to POD4 [Day 1: (6.7±8.4) g/L vs. (8.0±10.6) g/L; Day 2: (24.8±14.6) g/L vs. (28.3±21.1) g/L, Day 3: (54.8±26.5) g/L vs. (53.8±27.6)g/L, Day 4: (62.0±32.2) g/L vs. (58.4±30.7) g/L], while the differences were not significant (all P>0.05). At POD 5, the CRP lever of AL group increased continuously, while that of NAL group decreased with significant difference [(65.3±38.9) g/L vs. (44.7±39.5) g/L, t=-2.85, P=0.005]. Further stratification analysis on AL group revealed CRP level in early AL (AL occurrence POD 10) showed rising trend from POD 1 to 4, then decreased slightly at POD 5, but whose differences were not significant (all P>0.05). ROC curve was drawn with AL condition as state variables and CRP level as

  6. Analysis of Information Leakages on Laser Printers in the Media of Electromagnetic Radiation and Line Conductions

    OpenAIRE

    Ulaş, Cihan

    2016-01-01

    In this paper, the emissions of a laser printer, which may process classified information, are investigated in the media of electromagnetic radiation (ER), Power Line Conductors (PLC), and Signal Line Conductors (SLC). First, the candidate frequency points of CE are examined in the frequency domain. Second, the emitted signal is AM-demodulated with the proper bandwidth, and then sampled by a high storage oscilloscope in these frequency points. Third, the collected data is converted to 2D imag...

  7. THE Lyα LINE PROFILES OF ULTRALUMINOUS INFRARED GALAXIES: FAST WINDS AND LYMAN CONTINUUM LEAKAGE

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Crystal L.; Wong, Joseph [Department of Physics, University of California, Santa Barbara, CA, 93106 (United States); Dijkstra, Mark [Institute of Theoretical Astrophysics, University of Oslo, Postboks 1029, 0858 Oslo (Norway); Henry, Alaina [Astrophysics Science Division, Goddard Space Flight Center, Code 665, Greenbelt, MD 20771 (United States); Soto, Kurt T. [Institute for Astronomy, Department of Physics, ETH Zurich, CH-8093 Zurich (Switzerland); Danforth, Charles W., E-mail: cmartin@physics.ucsb.edu [CASA, Department of Astrophysical and Planetary Sciences, University of Colorado, 389-UCB, Boulder, CO, 80309 (United States)

    2015-04-10

    We present new Hubble Space Telescope Cosmic Origins Spectrograph far-ultraviolet (far-UV) spectroscopy and Keck Echellete optical spectroscopy of 11 ultraluminous infrared galaxies (ULIRGs), a rare population of local galaxies experiencing massive gas inflows, extreme starbursts, and prominent outflows. We detect Lyα emission from eight ULIRGs and the companion to IRAS09583+4714. In contrast to the P Cygni profiles often seen in galaxy spectra, the Lyα profiles exhibit prominent, blueshifted emission out to Doppler shifts exceeding −1000 km s{sup −1} in three H ii-dominated and two AGN-dominated ULIRGs. To better understand the role of resonance scattering in shaping the Lyα line profiles, we directly compare them to non-resonant emission lines in optical spectra. We find that the line wings are already present in the intrinsic nebular spectra, and scattering merely enhances the wings relative to the line core. The Lyα attenuation (as measured in the COS aperture) ranges from that of the far-UV continuum to over 100 times more. A simple radiative transfer model suggests the Lyα photons escape through cavities which have low column densities of neutral hydrogen and become optically thin to the Lyman continuum in the most advanced mergers. We show that the properties of the highly blueshifted line wings on the Lyα and optical emission-line profiles are consistent with emission from clumps of gas condensing out of a fast, hot wind. The luminosity of the Lyα emission increases nonlinearly with the ULIRG bolometric luminosity and represents about 0.1–1% of the radiative cooling from the hot winds in the H ii-dominated ULIRGs.

  8. Numerical study of electron-leakage power loss in a tri-plate transmission line

    International Nuclear Information System (INIS)

    Barker, R.J.; Goldstein, S.A.

    1982-01-01

    Numerical simulations have been conducted using NRL's DIODE2D computer code to model the steady-state behavior of electron flow in a radial diode and in its adjacent tri-plate transmission line (TTL). Particular attention was paid to the magnitude of the electron current flowing from the cathode to the anode surface in the TTL. A quantitative value for this effective power loss is given. The electron current is restricted mainly to the transition region in the TTL into which there is seepage of the B/sub z/ that is imposed in the diode gap. This finding highlights the importance of that region to diode designers

  9. Preventive testing and leakage detection in pipe-lines of steam condensers and generators of a PWR type reactor

    International Nuclear Information System (INIS)

    Canalini, A.; Carvalho, N.C. de

    1985-01-01

    The non-destructive methods: Spum, Helium and Hydrostatic used in leakage detection in condenser pipelines for PWR type reactors are presented. The time, costs, sensitivity, resources necessary and personnel development factors are considered to choose adequated method, in function of nuclear power plant conditions. The leakage tests are applied in pressurized systems or vacuum. Eddy Current testing is used in condensers and steam generators aiming to avoid leakage in these equipments. The spume testing for leakage detection in condenser pipelines - which operation - and hydrostatic testing for leakage detection through reaming with shutdown - were most efficients. The Helium testing applied in pressurized systems or submitted to vacuum systems presented satisfactory results. The Eddy Current testing in condenser and steam generator pipelines reached desired objective, reducing leakage in the first and preserving the integrity in the second. (M.C.K.) [pt

  10. On line monitoring of temperatures of coolant channels by thermal imaging in a laboratory set-up fabricated for the detection of leakage of coolants

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, S; Ghosh, J K [Bhabha Atomic Research Centre, Bombay (India). Radiometallurgy Div.; Patel, R J [Bhabha Atomic Research Centre, Mumbai (India). Refuelling Technology Division

    1994-12-31

    Leakage from coolant channels in Pressurised Heavy Water Reactors (PHWR) increases the temperatures of the faulty channels. Measurement of temperatures of the coolant channels is, therefore, one way to detect the leaking channel. Thermal imaging technique offers a unique means for this detection providing a fast, non-contact, on-line measurement. An experiment was carried out for the detection of leakage of coolants through the seal plugs of the coolant channels in PHWR using an experimental setup under the simulated conditions of temperature and pressure of the coolant channels inside the reactor and using an infrared imaging system. The experimental details and the observations have been presented. 7 figs.

  11. On line monitoring of temperatures of coolant channels by thermal imaging in a laboratory set-up fabricated for the detection of leakage of coolants

    International Nuclear Information System (INIS)

    Mukherjee, S.; Ghosh, J.K.; Patel, R.J.

    1994-01-01

    Leakage from coolant channels in Pressurised Heavy Water Reactors (PHWR) increases the temperatures of the faulty channels. Measurement of temperatures of the coolant channels is, therefore, one way to detect the leaking channel. Thermal imaging technique offers a unique means for this detection providing a fast, non-contact, on-line measurement. An experiment was carried out for the detection of leakage of coolants through the seal plugs of the coolant channels in PHWR using an experimental setup under the simulated conditions of temperature and pressure of the coolant channels inside the reactor and using an infrared imaging system. The experimental details and the observations have been presented. 7 figs

  12. The project of the technological line of the electronic-beam drains disinfection in the infected hospitals' divisions and tubercular centres

    International Nuclear Information System (INIS)

    Shlapatska, V.V.; Volkonsky, V.G.; Sakhno, V.I.; Tomchaj, S.P.

    1999-01-01

    The purpose of the project was to create the electrophysical facility for the environmental protection from contamination by drains of the infected hospitals' divisions and tubercular centres and prevention of open water reservoirs. Development of the economically approved methods of the radiative disinfection of contaminated drains; development of the inexpensive compact facility for the electron-beam disinfection of small volume drains

  13. Are there risk factors that increase the rate of staple line leakage in patients undergoing primary sleeve gastrectomy for morbid obesity?

    Science.gov (United States)

    Benedix, Frank; Benedix, Diana D; Knoll, Christian; Weiner, Rudolf; Bruns, Christiane; Manger, Thomas; Stroh, Christine

    2014-10-01

    Laparoscopic sleeve gastrectomy (LSG) is currently being performed with increasing frequency worldwide. It offers an excellent weight loss and resolution of comorbidities in the short term with a very low incidence of complications. However, the ever present risk of a staple line leak is still a major concern. Since 2005, data from obese patients that undergo bariatric procedures in Germany are prospectively registered in an online database and analyzed at the Institute of Quality Assurance in Surgical Medicine. For the current analysis, all patients that had undergone primary sleeve gastrectomy for morbid obesity within a 7-year period were considered. Using the GBSR, data from 5.400 LSGs were considered for analysis. Staple line leak rate decreased during the study period from 6.5 to 1.4 %. Male gender, higher BMI, concomitant sleep apnea, conversion to laparotomy, longer operation time, use of both buttresses and oversewing, and the occurrence of intraoperative complications were associated with a significantly higher leakage rate. On multivariate analysis, operation time and year of procedure only had a significant impact on staple line leak rate. The results of the current study demonstrated that there are factors that increase the risk of a leakage which would enable surgeons to define risk groups, to more carefully select patients, and to offer a closer follow-up during the postoperative course with early recognition and adequate treatment. All future efforts should be focused on a further reduction of serious complications to make the LSG a widely accepted and safer procedure.

  14. Replacement of the drain system of secondary circuit at Monju

    International Nuclear Information System (INIS)

    Itoh, Kenji; Onuki, Koji; Tomobe, Katsuma; Taniyama, Sadami

    2003-01-01

    Monju is as a Japan's prototype fast breeder reactor cooled by liquid sodium. In the course of power buildup tests, the sodium leakage accident broke out on 8th December 1995. Though Monju has been already equipped with countermeasure systems against the sodium leakage accident, some additional improvements will be taken in order to reduce the damage by the leaked sodium when another leakage accident should recur. The most characteristic work is the drain system modification that leads to shorten the drain time and to reduce the quantity of leaked sodium in the event of sodium leakage. (author)

  15. In-Line Acoustic Device Inspection of Leakage in Water Distribution Pipes Based on Wavelet and Neural Network

    Directory of Open Access Journals (Sweden)

    Dileep Kumar

    2017-01-01

    Full Text Available Traditionally permanent acoustic sensors leak detection techniques have been proven to be very effective in water distribution pipes. However, these methods need long distance deployment and proper position of sensors and cannot be implemented on underground pipelines. An inline-inspection acoustic device is developed which consists of acoustic sensors. The device will travel by the flow of water through the pipes which record all noise events and detect small leaks. However, it records all the noise events regarding background noises, but the time domain noisy acoustic signal cannot manifest complete features such as the leak flow rate which does not distinguish the leak signal and environmental disturbance. This paper presents an algorithm structure with the modularity of wavelet and neural network, which combines the capability of wavelet transform analyzing leakage signals and classification capability of artificial neural networks. This study validates that the time domain is not evident to the complete features regarding noisy leak signals and significance of selection of mother wavelet to extract the noise event features in water distribution pipes. The simulation consequences have shown that an appropriate mother wavelet has been selected and localized to extract the features of the signal with leak noise and background noise, and by neural network implementation, the method improves the classification performance of extracted features.

  16. 46 CFR 45.157 - Scuppers and gravity drains.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  17. In line inspection of multi-diameter and high-pressure pipelines in Brazil using combined technologies: magnetic flux leakage and ultrasonic testing

    Energy Technology Data Exchange (ETDEWEB)

    Ginten, Markus; Brockhaus, Stephan; Bouaoua, Nourreddine; Klein, Stefan [ROSEN Technology and Research Center, Lingen (Germany); Bruening, Franz [ROSEN Brazil, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The simultaneous use of the magnetic flux leakage (MFL) method and the ultrasonic testing (UT) method on a single in line inspection (ILI) tool has been identified as a versatile and accurate solution for liquid pipelines. The combination of the two methods is complementary to the restrictions of each other. Also, the overall scope of the inspection is enlarged. General wall thinning and largely corroded areas are accurately and reliably scanned with the UT unit, while very detailed information about pitting corrosion is obtained from the MFL measurement. Blind spots of echo loss, as occasionally observed for the UT channels is compensated by the more robust measurement from the MFL sensors. Consequently, this technology has been the method of choice in an in line inspection project of an onshore long distance pipeline in Brazil, facing a variety of corrosion threats. The pipeline consists of several multi-diameter sections of 18/20 inches and 20/22 inches. Furthermore, the high gravity of product in combination with a height profile, an altitude of 1152 m MSL (Mean Sea Level) had to be crossed, leads to a maximum pressure of 220 bar. These boundary conditions had to be considered during the design of the ILI-tool. The paper discusses the experience made so far with the combined technology MFL and UT. The effective use of the inspection tool for the above mentioned pipeline as well as field results from a previous inspection are described. (author)

  18. Method of detecting leakage in nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Koba, Akitoshi; Goto, Seiichiro.

    1974-01-01

    Object: To permit accurate and prompt detection of leakage of a radioactive substance. Structure: The rate of change of such factors as radiation dose, temperature and pressure in the containment vessel, and each detected rate of change is compared with a reference value. The running cycle of the condensed drain exhausting pump in a drain collecting tank within a predetermined period is detected, and it is also compared with a reference value. These comparisons determine the absence or presence of leakage. (Kamimura, M.)

  19. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  20. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  1. On Probability Leakage

    OpenAIRE

    Briggs, William M.

    2012-01-01

    The probability leakage of model M with respect to evidence E is defined. Probability leakage is a kind of model error. It occurs when M implies that events $y$, which are impossible given E, have positive probability. Leakage does not imply model falsification. Models with probability leakage cannot be calibrated empirically. Regression models, which are ubiquitous in statistical practice, often evince probability leakage.

  2. An experimental approach to determining subsurface leakage from a surface impoundment using a radioisotope tracer

    International Nuclear Information System (INIS)

    Ashwood, T.L.; Story, J.D.; Larsen, I.L.; Schultz, F.J.

    1987-01-01

    Bromine-82, a 35.3-h half-life radionuclide, was used as a tracer to determine the paths and rates of leakage from an unlined, 1,000,000-gal (3,785,000 L), surface impoundment at the Oak Ridge National Laboratory. Since the impoundment is underlain and surrounded by storm sewer and sanitary sewer lines (most of them predating the impoundment), known and suspected leak sites in storm drain catch basins and sanitary sewer manholes were sampled periodically and analyzed for 82 Br. A series of four ground water monitoring wells - three downgradient and one upgradient from the impoundment - were also sampled for 82 Br. Although the catch basin and manhole samples picked up 82 Br in leakage from the impoundment less than 5 h after application of the tracer, the monitoring well samples did not contain detectable levels of the radionuclide. It was concluded that the monitoring wells were sampling groundwater moving through the formation, whereas the storm drains and manholes were sampling water leading rapidly through secondary porosity and along preferred pathways. The decline in tracer concentration as a function of time was used to determine the residence time of water in the pond and hence the flow rate through the pond. This flow rate, when compared with the known outflow rate, indicated that the leakage flow was small. Hence, the main value of the test was to identify rapid leakage pathways. The experiment demonstrates the need for sampling subsurface drain systems as part of an integrated monitoring system for leak detection. The effectiveness of 82 Br as a tracer for rapid leaks was also shown

  3. Laparoscopic radical prostatectomy: omitting a pelvic drain

    Directory of Open Access Journals (Sweden)

    David Canes

    2008-03-01

    Full Text Available PURPOSE: Our goal was to assess outcomes of a selective drain placement strategy during laparoscopic radical prostatectomy (LRP with a running urethrovesical anastomosis (RUVA using cystographic imaging in all patients. Materials and Methods: A retrospective chart review was performed for all patients undergoing LRP between January 2003 and December 2004. The anastomosis was performed using a modified van Velthoven technique. A drain was placed at the discretion of the senior surgeon when a urinary leak was demonstrated with bladder irrigation, clinical suspicion for a urinary leak was high, or a complex bladder neck reconstruction was performed. Routine postoperative cystograms were obtained. RESULTS: 208 patients underwent LRP with a RUVA. Data including cystogram was available for 206 patients. The overall rate of cystographic urine leak was 5.8%. A drain was placed in 51 patients. Of these, 8 (15.6% had a postoperative leak on cystogram. Of the 157 undrained patients, urine leak was radiographically visible in 4 (2.5%. The higher leak rate in the drained vs. undrained cohort was statistically significant (p = 0.002. Twenty-four patients underwent pelvic lymph node dissection (8 drained, 16 undrained. Three undrained patients developed lymphoceles, which presented clinically on average 3 weeks postoperatively. There were no urinomas or hematomas in either group. CONCLUSIONS: Routine placement of a pelvic drain after LRP with a RUVA is not necessary, unless the anastomotic integrity is suboptimal intraoperatively. Experienced clinical judgment is essential and accurate in identifying patients at risk for postoperative leakage. When suspicion is low, omitting a drain does not increase morbidity.

  4. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    leakage from 'open to air' system or breakage of glass bottle (with associated risk to ... and an air-leak detection system. It is connected to a ... need to add water. Xpand chest drain: assessing equivalence to current standard therapy – a randomised controlled trial. CHARL COOPER, M.B. CH.B. TIMOTHY HARDCASTLE ...

  5. Leakage evaluation in the PCV (Primary Containment Vessel) using chemical and radiochemical data

    International Nuclear Information System (INIS)

    Maeda, Katsuji; Nagasawa, Katsumi

    1998-01-01

    Keeping the reliability of nuclear power plant operation, the primary coolant leakage in the PCV is strictly restricted by the Technical Specifications. It is very important to detect an indication of leakage and estimate the source of leakage to provide countermeasures. Usually the indication of leakage will be detected by increase of drain flow in the PCV sump. There are some possibilities of leakage sources in the PCV, such as reactor water, main steam, condensate, feedwater and closed cooling water. The leakage source contain different chemical and radiochemical species. This means that the leakage source can be presumed and detected by using chemical information from the PCV atmosphere and sump water. To detect the leakage indication and the source quickly and exactly, the PCV Leakage Detection Expert System has been developed. This paper describes how to evaluate the leakage indication and source in the PCV by using chemical and radiochemical data. (author)

  6. Application of resin lining system for countermeasures for preventing leakage from openings in low temperature materials storage; Teion busshitsu chozoji no ekimore oyobi reiki more taisaku toshite no kobunshikei zairyo no tekiyosei

    Energy Technology Data Exchange (ETDEWEB)

    Inada, Y. [Ehime Univ., Ehime (Japan). Faculty of Engineering; Seki, S.

    1996-12-21

    Recently, many of the low temperature materials such as LNG and LPG used as an energy substitution for petroleum were stored in the reclaimed land of the sea side district, however, it is necessary for those storage methods to enlarge sites. Therefore, it was considered to directly store the low temperature materials in openings excavated in the rock mountains. However, countermeasures for leakage of liquid and cold gas from cracks in openings would be an important subject. In this study, as a countermeasure for leakage of liquid and cold gas in the case in which low temperature materials were stored in openings in the rock mountains, the lining of resin materials on the surface of openings was proposed. Characteristics of strength and deformation and values of the thermal physical properties for the resin materials at the low temperature were obtained by experiments. This material was compared with granite supposed as a parent rock, and the thermal property of the resin materials was understood. Next, an analysis was conducted in the case of using the resin materials as a lining, the behavior of the surrounding rocks of the openings and the stability of the lining were investigated. 17 refs., 25 figs., 2 tabs.

  7. Using Smoke Injection in Drains to Identify Potential Preferential Pathways in a Drained Arable Field

    Science.gov (United States)

    Nielsen, M. H.; Petersen, C. T.; Hansen, S.

    2014-12-01

    Macropores forming a continuous pathway between the soil surface and subsurface drains favour the transport of many contaminants from agricultural fields to surface waters. The smoke injection method presented by Shipitalo and Gibbs (2000) used for demonstrating and quantifying such pathways has been further developed and used on a drained Danish sandy loam. In order to identify the preferential pathways to drains, smoke was injected in three 1.15 m deep tile drains (total drain length 93 m), and smoke emitting macropores (SEMP) at the soil surface were counted and characterized as producing either strong or weak plumes compared to reference plumes from 3 and 6 mm wide tubes. In the two situations investigated in the present study - an early spring and an autumn situation, smoke only penetrated the soil surface layer via earthworm burrows located in a 1.0 m wide belt directly above the drain lines. However, it is known from previous studies that desiccation fractures in a dry summer situation also can contribute to the smoke pattern. The distance between SEMP measured along the drain lines was on average 0.46 m whereas the average spacing between SEMP with strong plumes was 2.3 m. Ponded water was applied in 6 cm wide rings placed above 52 burrows including 17 reference burrows which did not emit smoke. Thirteen pathways in the soil were examined using dye tracer and profile excavation. SEMP with strong plumes marked the entrance of highly efficient transport pathways conducting surface applied water and dye tracer into the drain. However, no single burrow was traced all the way from the surface into the drain, the dye patterns branched off in a network of other macropores. Water infiltration rates were significantly higher (P drains and surface waters, pathways being associated primarily with unevenly distributed SEMP producing strong smoke plumes.

  8. Mechanism of improving forward and reverse blocking voltages in AlGaN/GaN HEMTs by using Schottky drain

    International Nuclear Information System (INIS)

    Zhao Sheng-Lei; Mi Min-Han; Luo Jun; Wang Yi; Dai Yang; Zhang Jin-Cheng; Ma Xiao-Hua; Hao Yue; Hou Bin

    2014-01-01

    In this paper, we demonstrate that a Schottky drain can improve the forward and reverse blocking voltages (BVs) simultaneously in AlGaN/GaN high-electron mobility transistors (HEMTs). The mechanism of improving the two BVs is investigated by analysing the leakage current components and by software simulation. The forward BV increases from 72 V to 149 V due to the good Schottky contact morphology. During the reverse bias, the buffer leakage in the Ohmicdrain HEMT increases significantly with the increase of the negative drain bias. For the Schottky-drain HEMT, the buffer leakage is suppressed effectively by the formation of the depletion region at the drain terminal. As a result, the reverse BV is enhanced from −5 V to −49 V by using a Schottky drain. Experiments and the simulation indicate that a Schottky drain is desirable for power electronic applications. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  9. Abdominal Drainage and Amylase Measurement for Detection of Leakage After Gastrectomy for Gastric Cancer.

    Science.gov (United States)

    Schots, Judith P M; Luyer, Misha D P; Nieuwenhuijzen, Grard A P

    2018-05-07

    To investigate the value of daily measurement of drain amylase for detecting leakage in gastric cancer surgery. This was a retrospective analysis including all patients who underwent a gastrectomy for gastric cancer. From January 2013 until December 2015, an intra-abdominal drain was routinely placed. Drain amylase was measured daily. Receiver operator characteristic curves were created to assess the ability of amylase to predict leakage. Sensitivity, specificity, and negative and positive predictive value of amylase in drain fluid were determined. Leakage of the gastrojejunostomy or esophagojejunostomy, enteroenterostomy, duodenal stump, or pancreas was diagnosed by CT scan, endoscopy, or during re-operation. From January 2016 until April 2017, no drain was inserted. Surgical outcome and postoperative complications were compared between both groups. Median drain amylase concentrations were higher for each postoperative day in patients with leakage. The optimal cutoff value was 1000 IU/L (sensitivity 77.8%, specificity 98.2%, negative predictive value 96.6%). Sixty-seven consecutive procedures were performed with a drain and 40 procedures without. No differences in group characteristics were observed except for gender. Fourteen patients (13.1%) had a leakage. The incidence and severity of leakage were not different between the patients with and without a drain. There was no significant difference in time to diagnosis (1 vs. 0 days; p 0.34), mortality rate (7.5 vs. 2.5%; p 0.41), and median length of hospital stay (9 days in both groups; p 0.46). Daily amylase measurement in drain fluid does not influence the early recognition and management of leakage in gastric cancer surgery.

  10. Analysis of ONKALO water leakage mapping results

    International Nuclear Information System (INIS)

    Ahokas, H.; Nummela, J; Turku, J.

    2014-04-01

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  11. Analysis of ONKALO water leakage mapping results

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Nummela, J; Turku, J. [Poeyry Finland Oy, Vantaa (Finland)

    2014-04-15

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  12. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  13. Thailand and brain drain

    Directory of Open Access Journals (Sweden)

    Terry Commins

    2009-01-01

    Full Text Available Brain drain has been the subject of research since the 1960s. This research has been hampered by a lack of accurate data from both source and receiving countries on migration and on the losses and gains to developing economies of skilled migration. However, despite these handicaps, research has been able to clearly show that trends are changing and the effect this is having is usually quite different for individual source countries.Thailand, as a developing economy, could be regarded as a source country. Fortunately, Thailand has never ranked highly in terms of brain drain when compared to other states in Asia and while it may not be a significant problem it nonetheless needs to be monitored. Thailand is also somewhat unique in that the migration that has occurred has been almost equally split between secondary and tertiary educated Thais. Thailand also ranks low in terms of tertiary educated population who have migrated when compared to other countries in the region. Globalisation is having a profound effect on the migration of skilled workers. As trade becomes increasingly free, barriers to the movement of services or people are also freed. As the better educated are encouraged to think globally, so too will they be inclined to move globally into the world community.This paper examines Thailand’s position with respect to brain drain, some of the lessons we have learned and some of the steps that are being taken to minimise the impact of the loss of skilled workers, with a particular focus on science and technology. The conclusion is that brain drain should not be viewed as an entirely negative development and that the positive outcomes should be recognised, encouraged and incorporated into policy.

  14. Globalization, Brain Drain, and Development

    OpenAIRE

    Docquier, Frédéric; Rapoport, Hillel

    2012-01-01

    This paper reviews four decades of economics research on the brain drain, with a focus on recent contributions and on development issues. We first assess the magnitude, intensity, and determinants of the brain drain, showing that brain drain (or high-skill) migration is becoming a dominant pattern of international migration and a major aspect of globalization. We then use a stylized growth model to analyze the various channels through which a brain drain affects the sending countries and revi...

  15. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  16. Data leakage quantification

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.; Atluri, V.; Pernul, G.

    2014-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. These solutions often produce a large number of alerts, whose

  17. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  18. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  19. Radioactivity leakage monitoring system

    International Nuclear Information System (INIS)

    Nakajima, Takuichiro; Noguchi, Noboru.

    1982-01-01

    Purpose: To obtain a device for detecting the leakage ratio of a primary coolant by utilizing the variation in the radioactivity concentration in a reactor container when the coolant is leaked. Constitution: A measurement signal is produced from a radioactivity measuring instrument, and is continuously input to a malfunction discriminator. The discriminator inputs a measurement signal to a concentration variation discriminator when the malfunction is recognized and simultaneously inputs a measurement starting time from the inputting time to a concentration measuring instrument. On the other hand, reactor water radioactivity concentration data obtained by sampling the primary coolant is input to a concentration variation computing device. A comparator obtains the ratio of the measurement signal from the measuring instrument and the computed data signal from the computing device at the same time and hence the leakage rate, indicates the average leakage rate by averaging the leakage rate signals and also indicates the total leakage amount. (Yoshihara, H.)

  20. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  1. Climate mitigation scenarios of drained peat soils

    Science.gov (United States)

    Kasimir Klemedtsson, Åsa; Coria, Jessica; He, Hongxing; Liu, Xiangping; Nordén, Anna

    2014-05-01

    The national inventory reports (NIR) submitted to the UNFCCC show Sweden - which as many other countries has wetlands where parts have been drained for agriculture and forestry purposes, - to annually emit 12 million tonnes carbon dioxide equivalents, which is more GHG'es than industrial energy use release in Sweden. Similar conditions can be found in other northern countries, having cool and wet conditions, naturally promoting peat accumulation, and where land use management over the last centuries have promoted draining activities. These drained peatland, though covering only 2% of the land area, have emissions corresponding to 20% of the total reported NIR emissions. This substantial emission contribution, however, is hidden within the Land Use Land Use Change and Forestry sector (LULUCF) where the forest Carbon uptake is even larger, which causes the peat soil emissions become invisible. The only drained soil emission accounted in the Swedish Kyoto reporting is the N2O emission from agricultural drained organic soils of the size 0.5 million tonnes CO2e yr-1. This lack of visibility has made incentives for land use change and management neither implemented nor suggested, however with large potential. Rewetting has the potential to decrease soil mineralization, why CO2 and N2O emissions are mitigated. However if the soil becomes very wet CH4 emission will increase together with hampered plant growth. By ecological modeling, using the CoupModel the climate change mitigation potential have been estimated for four different land use scenarios; 1, Drained peat soil with Spruce (business as usual scenario), 2, raised ground water level to 20 cm depth and Willow plantation, 3, raised ground water level to 10 cm depth and Reed Canary Grass, and 4, rewetting to an average water level in the soil surface with recolonizing wetland plants and mosses. We calculate the volume of biomass production per year, peat decomposition, N2O emission together with nitrate and DOC

  2. Thailand and brain drain

    OpenAIRE

    Terry Commins

    2009-01-01

    Brain drain has been the subject of research since the 1960s. This research has been hampered by a lack of accurate data from both source and receiving countries on migration and on the losses and gains to developing economies of skilled migration. However, despite these handicaps, research has been able to clearly show that trends are changing and the effect this is having is usually quite different for individual source countries.Thailand, as a developing economy, could be regarded as a sou...

  3. Charge plasma based source/drain engineered Schottky Barrier MOSFET: Ambipolar suppression and improvement of the RF performance

    Science.gov (United States)

    Kale, Sumit; Kondekar, Pravin N.

    2018-01-01

    This paper reports a novel device structure for charge plasma based Schottky Barrier (SB) MOSFET on ultrathin SOI to suppress the ambipolar leakage current and improvement of the radio frequency (RF) performance. In the proposed device, we employ dual material for the source and drain formation. Therefore, source/drain is divided into two parts as main source/drain and source/drain extension. Erbium silicide (ErSi1.7) is used as main source/drain material and Hafnium metal is used as source/drain extension material. The source extension induces the electron plasma in the ultrathin SOI body resulting reduction of SB width at the source side. Similarly, drain extension also induces the electron plasma at the drain side. This significantly increases the SB width due to increased depletion at the drain end. As a result, the ambipolar leakage current can be suppressed. In addition, drain extension also reduces the parasitic capacitances of the proposed device to improve the RF performance. The optimization of length and work function of metal used in the drain extension is performed to achieve improvement in device performance. Moreover, the proposed device makes fabrication simpler, requires low thermal budget and free from random dopant fluctuations.

  4. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  5. Coolant leakage detecting device

    International Nuclear Information System (INIS)

    Yamauchi, Kiyoshi; Kawai, Katsunori; Ishihara, Yoshinao.

    1995-01-01

    The device of the present invention judges an amount of leakage of primary coolants of a PWR power plant at high speed. Namely, a mass of coolants contained in a pressurizer, a volume controlling tank and loop regions is obtained based on a preset relational formula and signals of each of process amount, summed up to determine the total mass of coolants for every period of time. The amount of leakage for every period of time is calculated by a formula of Karman's filter based on the total mass of the primary coolants for every predetermined period of time, and displays it on CRT. The Karman's filter is formed on every formula for several kinds of states formed based on the preset amount of the leakage, to calculate forecasting values for every mass of coolants. An adaptable probability for every preset leakage amount is determined based on the difference between the forecast value and the observed value and the scattering thereof. The adaptable probability is compared with a predetermined threshold value, which is displayed on the CRT. This device enables earlier detection of leakage and identification of minute leakage amount as compared with the prior device. (I.S.)

  6. Leakage detection system in nuclear reactor container

    International Nuclear Information System (INIS)

    Kurosawa, Masahiko.

    1993-01-01

    The present invention comprises an injection means for adding radioactive materials to coolants in a container cooler, a gamma ray amplitude analyzer connected to coolant pipelines and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to a drain water sump and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to various kinds of pipelines and a means for recording/transferring the data of the result of the measurement, and a data processing means for comparing and analyzing the measured data of each of the gamma ray amplitude analyzers inputted from each of date recording/transferring means. The gamma ray amplitude analysis for each of the pipelines and drain water sump are conducted at an appropriate frequency, and the measured data are compared and analyzed, to improve the detection accuracy for a trace amount of leakage from each of the pressure pipelines and the container cooler coolant pipelines, thereby enabling to specify the pipeline having leakage. Maintenance efficiency is improved, and severe rupture accident in each of pressure pipelines is prevented previously. (N.H.)

  7. Drains and Drainage Capabilities: Quantitative Analysis of Drain Efficiencies

    Directory of Open Access Journals (Sweden)

    Andaç Aykan

    2016-03-01

    Full Text Available Objective: In this study, it was aimed to compare the efficiency of the same type of but different-sized silicone drains at different surgical procedures. Material and Methods: Twenty-four patients, who had different diagnoses and were operated between 2011 and 2013, were included. In all patients, 7- and 10-mm silicone-ended, Jackson–Pratt drains were used. Drains that were under 30 cc/day removed. The connection tube and perforated silicone end were examined due to the clot content. All drain efficiencies were calculated, and the results were statistically analyzed. Results: Seven of the 24 patients (29.2% were males and 17 (70.8% were females; the mean age was 39.0±11.4 years. Totally, 49 drains were used, of which 25 (51% were 7 mm and 24 (49% were 10 mm in size. Median removal time was the 5th day (2–12 for the 7-mm drains and the 6th day (3–14 for the 10-mm drains. There was no statistically significant difference between the groups for drain removal time (p=0.268. Further, there was no difference at the connection tube and silicone end for clot content between the 7- and 10-mm drains (p=0.58. For the drainage volume and efficiency, no difference was observed between the groups (p=0.146. Conclusion: In this study it was observed that there is no difference in the drainage volume and efficiency between different-sized Jackson–Pratt drains.

  8. Coolant leakage detection device

    International Nuclear Information System (INIS)

    Ito, Takao.

    1983-01-01

    Purpose: To surely detect the coolant leakage at a time when the leakage amount is still low in the intra-reactor inlet pipeway of FBR type reactor. Constitution: Outside of the intra-reactor inlet piping for introducing coolants at low temperature into a reactor core, an outer closure pipe is furnished. The upper end of the outer closure pipe opens above the liquid level of the coolants in the reactor, and a thermocouple is inserted to the opening of the upper end. In such a structure, if the coolants in the in-reactor piping should leak to the outer closure pipe, coolants over-flows from the opening thereof, at which the thermocouple detects the temperature of the coolants at a low temperature, thereby enabling to detect the leakage of the coolants at a time when it is still low. (Kamimura, M.)

  9. Treatment of bilge and oily drain water of tankers and current measures against combustible oil gas discharge; Tanker no biruji yudakusui shori oyobi kanensei sekiyu gas haishutsu taiskau no genjo

    Energy Technology Data Exchange (ETDEWEB)

    Agatsuma, Y.

    1996-07-25

    This paper describes the current actual conditions on treatment of bilge discharged from engine area and oily drain water from cargo area of tankers. Clean bilge among various bilges discharged from engine area such as vapor drain, fresh water, rainwater, seawater and condensed water is directly dumped into the sea after temporary storage in a clean tank. Oily bilge is produced mainly by mixing of clean bilge and leakage oil from main engines and various auxiliaries. Oily bilge is dumped into the sea under comparative monitoring of the bilge quality with the dumping standard by oil concentration monitoring and control equipment after the primary treatment in a treatment tank and the secondary treatment in a bilge separator. Oily drain water from cargo area contains water ballast for cargo oil tanks, wash water for tanks and lines, and bilge produced in pump room. The oily drain water is dumped under a specific condition. However, water ballast for specific ballast tanks is excluded from the oily drain water. 2 figs.

  10. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  11. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  12. Roxby Downs water leakage

    International Nuclear Information System (INIS)

    1996-01-01

    The Environment, Resource and development Committee has been asked by Parliament to examine 'a massive leakage of water at Roxby Downs' and to make recommendations 'as to further action'. It has also been specifically asked to comment on 'the desirability of the Department of Mines and Energy having prime responsibility for environmental matters in relation to mining operations'. This report begins with a description of the Olympic Dam operations near Roxby Downs and with a brief overview of the regulations controlling those operations. The site of the leakage the Olympic Dam tailings retention system is then described in greater detail. Part 3 describes how the system was originally designed, modified and approved. It ends with a series of findings about the adequacy of the original design (including the monitoring systems built into it) and of the approvals process. Recommendations are then made about how future approvals should be handled. Part 4 of the report outlines how the tailings retention system was built and operated and how the massive leakage from it was detected and reported. Findings about the adequacy of the management of the system and about the initial reactions to the leakage are then made, together with recommendations designed to improve future management of the system. 25 refs., 15 figs

  13. Plumbing the brain drain.

    Science.gov (United States)

    Saravia, Nancy Gore; Miranda, Juan Francisco

    2004-08-01

    Opportunity is the driving force of migration. Unsatisfied demands for higher education and skills, which have been created by the knowledge-based global economy, have generated unprecedented opportunities in knowledge-intensive service industries. These multi-trillion dollar industries include information, communication, finance, business, education and health. The leading industrialized nations are also the focal points of knowledge-intensive service industries and as such constitute centres of research and development activity that proactively draw in talented individuals worldwide through selective immigration policies, employment opportunities and targeted recruitment. Higher education is another major conduit of talent from less-developed countries to the centres of the knowledge-based global economy. Together career and educational opportunities drive "brain drain and recirculation". The departure of a large proportion of the most competent and innovative individuals from developing nations slows the achievement of the critical mass needed to generate the enabling context in which knowledge creation occurs. To favourably modify the asymmetric movement and distribution of global talent, developing countries must implement bold and creative strategies that are backed by national policies to: provide world-class educational opportunities, construct knowledge-based research and development industries, and sustainably finance the required investment for these strategies. Brazil, China and India have moved in this direction, offering world-class education in areas crucial to national development, such as biotechnology and information technology, paralleled by investments in research and development. As a result, only a small proportion of the most highly educated individuals migrate from these countries, and research and development opportunities employ national talent and even attract immigrants.

  14. Configuration of particle drain for the high energy charged particles in the magnetic dipole field

    International Nuclear Information System (INIS)

    Amirkhanov, I.V.; Zhidkov, E.P.; Ignatov, V.V.; Il'ina, A.N.; Il'in, V.D.; Kuznetsov, S.N.; Yushkov, B.Yu.

    1987-01-01

    The boundary of particle leakage from the magnetic dipole trap depending on the value of adiabatic parameter is investigated. By trajectory computation a generalized analytical expression is determined for the shape of particle drain by x ≤ 1. It is shown that generally accepted adiabatic loss cone is a particular case of x → 0

  15. Management and prevention of chylous leakage after laparoscopic lymphadenectomy.

    Science.gov (United States)

    Han, L-P; Zhang, H-M; Abha, H-D; Liu, T; Zhang, X-P

    2014-01-01

    To investigate the development and management of chylous leakage after laparoscopic retroperitoneal lymphadenectomy. From July 2006 to September 2013, 13 cases of chylous leakage after the laparoscopic lymphadenectomy (6 cases of renal cell carcinoma, 4 cases of gastric cancer, 2 cases of ovarian cancer, 1 case of endometrial cancer) were studied to analyze the occurrence, development and management of chylous leakage. In 3 cases (2 cases of renal cell carcinoma, 1 case of gastric cancer) massive amount of milky fluid drainage was be seen after the first two days post operation. Dietary intervention, TPN (total parenteral nutrition), somatostatin therapy, maintenance of continuous drainage helped to successfully manage the condition in about 1 month duration. In the remaining 10 cases, chylous leakage appeared after restoring normal diet. Managed with changes in diet and maintenance of unobstructed drainage, they were cured in about 2 weeks after treatment. There was significant reduction in drain output, ultrasonography did not reveal presence of free fluid collection in abdomen, and the patients were in good condition without signs and symptoms of infections. Chylous leakage is a rare complication of retroperitoneal lymph node dissection. Surgeons should be familiar with laparoscopic techniques, relevant anatomy and be aware of the fact that the effect of CO2 pressure and use of ultrasonic knife to occlude the lymphatic vessel can transiently block the leakage making the surgeon overlook them. Routine placement of indwelling drainage tube, immediate diagnosis, dietary modification, TPN, somatostatin and drainage are the modalities of conservative management.

  16. Colorectal Anastomotic Leakage: New perspectives

    NARCIS (Netherlands)

    F. Daams (Freek)

    2014-01-01

    markdownabstract__Abstract__ This thesis provides new perspectives on colorectal anastomotic leakages. In both experimental and clinical studies, aspects of prevention, early identification, treatment and consequences of anastomotic leakage are discussed.

  17. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  18. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.

    Science.gov (United States)

    Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho

    2011-05-01

    A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  19. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple’s Operation

    Directory of Open Access Journals (Sweden)

    Sang Ho Bae

    2011-05-01

    Full Text Available A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  20. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  1. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  2. Circuital model for the spherical geodesic waveguide perfect drain

    Science.gov (United States)

    González, Juan C.; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan C.

    2012-08-01

    The perfect drain for the Maxwell fish eye (MFE) is a non-magnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity that depends on frequency. However, this material is only a theoretical material, so it cannot be used in practical devices. The perfect drain has been claimed as necessary for achieving super-resolution (Leonhardt 2009 New J. Phys. 11 093040), which has increased the interest in practical perfect drains suitable for manufacturing. Here, we present a practical perfect drain that is designed using a simple circuit (made of a resistance and a capacitor) connected to the coaxial line. Moreover, we analyze the super-resolution properties of a device equivalent to the MFE, known as a spherical geodesic waveguide, loaded with this perfect drain. The super-resolution analysis for this device is carried out using COMSOL Multiphysics. The results of simulations predict a super-resolution of up to λ/3000.

  3. Circuital model for the spherical geodesic waveguide perfect drain

    International Nuclear Information System (INIS)

    González, Juan C; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan C

    2012-01-01

    The perfect drain for the Maxwell fish eye (MFE) is a non-magnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity that depends on frequency. However, this material is only a theoretical material, so it cannot be used in practical devices. The perfect drain has been claimed as necessary for achieving super-resolution (Leonhardt 2009 New J. Phys. 11 093040), which has increased the interest in practical perfect drains suitable for manufacturing. Here, we present a practical perfect drain that is designed using a simple circuit (made of a resistance and a capacitor) connected to the coaxial line. Moreover, we analyze the super-resolution properties of a device equivalent to the MFE, known as a spherical geodesic waveguide, loaded with this perfect drain. The super-resolution analysis for this device is carried out using COMSOL Multiphysics. The results of simulations predict a super-resolution of up to λ/3000. (paper)

  4. Origin of the water drained by the tunnel Graton

    International Nuclear Information System (INIS)

    Plata B, A.

    1992-12-01

    The research of the origin of the water drained by the Graton tunnel was attempted using isotope techniques. During the period of studies (April 1989-October 1992), four field work was executed to sample waters for chemistry, stable isotope and Tritium analysis, an to inject tracers and verify the possible infiltration from the Rimac and Blanco rivers to the tunnel. The results of the stable isotope analysis show that the water drained by the Graton tunnel comes from a basin around 300 meters above the average altitude of the basin where the Graton is located. The Tritium analysis show that the water is relatively modern. Using the model of total mixing, the residence times of the water drained at the km 0.5 and 2.5 are in the order to 45 years. The conductivities of the water of the tunnel is higher than the Rimac river ones because the influence of mine water. The chemical analysis of the water sampled at the downstream end of the tunnel, show that the conservative ions of the water kept almost constant during more than two years. The results of the work with artificial tracer show that there is no significant leakage from the Rimac and Blanco rivers to the Graton tunnel. So far, it can be concluded as a preliminary approach that the Graton tunnel drains relatively modern water originated in another basin. The hydrodynamics of the area of study seems to include a large storage on underground water in the system. The topography, geology and isotopic composition of the water samples, points to the upper Mantaro river basin as the possible source of part of the water drained by the Graton tunnel. (authors). 20 p. 2 figs., 7 ills., 4 tabs

  5. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  6. Band to Band Tunneling (BBT) Induced Leakage Current Enhancement in Irradiated Fully Depleted SOI Devices

    Science.gov (United States)

    Adell, Phillipe C.; Barnaby, H. J.; Schrimpf, R. D.; Vermeire, B.

    2007-01-01

    We propose a model, validated with simulations, describing how band-to-band tunneling (BBT) affects the leakage current degradation in some irradiated fully-depleted SOI devices. The dependence of drain current on gate voltage, including the apparent transition to a high current regime is explained.

  7. Closed suction drain with bulb

    Science.gov (United States)

    ... of gloves. Put a new bandage around the drain tube site. Use surgical tape to hold it down ... small amount of redness is normal). There is drainage from the skin around the tube site. There is more tenderness and swelling at ...

  8. Radiation-induced off-state leakage current in commercial power MOSFETs

    International Nuclear Information System (INIS)

    Dodd, Paul Emerson; Shaneyfelt, Marty Ray; Draper, Bruce Leroy; Felix, James Andrew; Schwank, James Ralph; Dalton, Scott Matthew

    2005-01-01

    The total dose hardness of several commercial power MOSFET technologies is examined. After exposure to 20 krad(SiO 2 ) most of the n- and p-channel devices examined in this work show substantial (2 to 6 orders of magnitude) increases in off-state leakage current. For the n-channel devices, the increase in radiation-induced leakage current follows standard behavior for moderately thick gate oxides, i.e., the increase in leakage current is dominated by large negative threshold voltage shifts, which cause the transistor to be partially on even when no bias is applied to the gate electrode. N-channel devices biased during irradiation show a significantly larger leakage current increase than grounded devices. The increase in leakage current for the p-channel devices, however, was unexpected. For the p-channel devices, it is shown using electrical characterization and simulation that the radiation-induced leakage current increase is related to an increase in the reverse bias leakage characteristics of the gated diode which is formed by the drain epitaxial layer and the body. This mechanism does not significantly contribute to radiation-induced leakage current in typical p-channel MOS transistors. The p-channel leakage current increase is nearly identical for both biased and grounded irradiations and therefore has serious implications for long duration missions since even devices which are usually powered off could show significant degradation and potentially fail.

  9. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  10. Novel technique of source and drain engineering for dual-material double-gate (DMDG) SOI MOSFETS

    Science.gov (United States)

    Yadav, Himanshu; Malviya, Abhishek Kumar; Chauhan, R. K.

    2018-04-01

    The dual-metal dual-gate (DMDG) SOI has been used with Dual Sided Source and Drain Engineered 50nm SOI MOSFET with various high-k gate oxide. It has been scrutinized in this work to enhance its electrical performance. The proposed structure is designed by creating Dual Sided Source and Drain Modification and its characteristics are evaluated on ATLAS device simulator. The consequence of this dual sided assorted doping on source and drain side of the DMDG transistor has better leakage current immunity and heightened ION current with higher ION to IOFF Ratio. Which thereby vesting the proposed device appropriate for low power digital applications.

  11. Condensate-polisher resin-leakage quantification and resin-transport studies

    International Nuclear Information System (INIS)

    Stauffer, C.C.; Doss, P.L.

    1983-04-01

    The objectives of this program were to: (1) determine the extent of resin leakage from current generation condensate polisher systems, both deep bed and powdered resin design, during cut-in, steady-state and flow transient operation, (2) analyze moisture separator drains and other secondary system samples for resin fragments and (3) document the level of organics in the secondary system. Resin leakage samples were obtained from nine-power stations that have either recirculating steam generators or once through steam generators. Secondary system samples were obtained from steam generator feedwater, recirculating steam generator blowdown and moisture separator drains. Analysis included ultraviolet light examination, SEM/EDX, resin quantification and infrared analysis. Data obtained from the various plants were compared and factors affecting resin leakage were summarized

  12. Method of processing laundry drain

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Y; Oda, A; Yusa, H; Kitamura, M; Horiuchi, S

    1979-09-28

    Purpose: To subject the laundry drain to flocculation precipitation treatment in the prior stage of an inverse osmotic treatment, and subject only the supernatant to the inverse osmotic treatment and the precipitate directly to the condensation treatment, thereby decreasing the frequency of exchange of the inverse osmotic membranes, and reducing the quantity of purifying water. Method: The laundry drain is supplied to a flocculation precipitation tank, and added and mixed with a flocculant and a neutralizing agent, thus being subjected to a flocculation precipitation treatment. The supernatant is transported to a circulation tank through a transportation pipe, and is subjected to an inverse osmotic treatment in inverse osmotic module through the circulation tank, a filter and a high tension pump, and then returned to the circulation tank. The supernatant is thus concentrated to a predetermined concentration by repeating such operations. On the other hand, the precipitate at the bottom part of the flocculation precipitation tank is supplied through the transportation pipe to an evaporator supply tank together with the concentrate from the drain circulation tank, and evaporated and concentrated in the evaporator.

  13. Improving off-state leakage characteristics for high voltage AlGaN/GaN-HFETs on Si substrates

    Science.gov (United States)

    Moon, Sung-Woon; Twynam, John; Lee, Jongsub; Seo, Deokwon; Jung, Sungdal; Choi, Hong Goo; Shim, Heejae; Yim, Jeong Soon; Roh, Sungwon D.

    2014-06-01

    We present a reliable process and design technique for realizing high voltage AlGaN/GaN hetero-junction field effect transistors (HFETs) on Si substrates with very low and stable off-state leakage current characteristics. In this work, we have investigated the effects of the surface passivation layer, prepared by low pressure chemical vapor deposition (LPCVD) of silicon nitride (SiNx), and gate bus isolation design on the off-state leakage characteristics of metal-oxide-semiconductor (MOS) gate structure-based GaN HFETs. The surface passivated devices with gate bus isolation fully surrounding the source and drain regions showed extremely low off-state leakage currents of less than 20 nA/mm at 600 V, with very small variation. These techniques were successfully applied to high-current devices with 80-mm gate width, yielding excellent off-state leakage characteristics within a drain voltage range 0-700 V.

  14. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  15. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  16. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  17. State waste discharge permit application, 200-E chemical drain field

    International Nuclear Information System (INIS)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field

  18. State waste discharge permit application, 200-E chemical drain field

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field.

  19. Laparoscopic primary repair and isoperistaltic endoluminal drain for Boerhaave's Syndrome.

    Science.gov (United States)

    Prete, Francesco; Pezzolla, Angela; Nitti, Paolo; Prete, Fernando

    2015-01-01

    Spontaneous oesophageal rupture, also known as Boerhaave syndrome (BS), is a rare and potentially lethal pathological condition. BS recognition is difficult, while rapidity of diagnosis, along with extension of the lesion, affects type and outcome of treatment. BS was classically treated by thoracotomy, but laparoscopic (LS), thoracoscopic (TS) surgery, and nonsurgical procedures as endoscopic stent positioning or use of glues have been described. Still, there is no model treatment, and selection of the most appropriate therapeutic procedure is complex in the absence of standardised criteria. We successfully managed a patient affected with BS by LS approach and present our experience along with a review of treatment options so far described. Our treatment integrated positioning of an oesophageal isoperistaltic endoluminal drain (IED), that we routinely use in oesophageal sutures at risk of leakage, and of which there is no previous report in the setting of BS. A 68 year old man presented to our attention with true BS, suspected on chest-abdominal CT scan and confirmed by upper GI contrast swallow test, showing leakage of hydro-soluble contrast from the lower third of the oesophagus. Of note, pleural cavities appeared intact. We performed an urgent laparoscopy 12 hours after the onset of symptoms. Laparoscopic toilet of the inferior mediastinum and dual layer oesophageal repair with pedicled omental flap were complemented by positioning of IED, feeding jejunostomy and two tubular drains. The patient had a slow but consistent recovery where IED played as a means of oesophageal suture protection, until he could be discharged home. We think that, when integrity of the pleura is documented, LS should be priority choice to avoid contamination of the pleural cavities. We have to consider every type of oesophageal repair in BS at risk of failure, and every means of protection of the suture is opportune. In our patient the oesophageal suture, covered with a flap of omentum

  20. Stress corrosion on austenitic stainless steels components after sodium draining

    International Nuclear Information System (INIS)

    Champeix, L.; Baque, P.; Chairat, C.

    1980-04-01

    The damage study performed on 316 pipes of a loop after two leakages allows to conclude that a stress corrosion process in sodium hydroxide environment has induced trans-crystaline cracks. The research of conditions inducing such a phenomenon is developed, including parametric tests under uniaxial load and some tests on pipe with welded joints. In aqueous sodium hydroxide, two corrosion processes have been revealed: a general oxidization increasing with environment aeration and a transcrystalline cracking appearing for stresses of the order of yield strength. Other conditions such a temperature (upper than 100 0 C) and time exposures (some tens of hours) are necessary. Cautions in order to limit introduction of wet air into drained loop and a choice of appropriate preheating conditions when restarting the installation must permit to avoid such a type of incident

  1. Early detection of anastomotic leakage after elective low anterior resection.

    Science.gov (United States)

    Fouda, Elyamani; El Nakeeb, Ayman; Magdy, Alaa; Hammad, Enas A; Othman, Gamal; Farid, Mohamed

    2011-01-01

    Colorectal anastomotic leakage is a serious complication leading to major postoperative morbidity and mortality. In the present study, we investigated the early detection of anastomotic leakage before its clinical presentation. Fifty-six patients with rectal cancer were included prospectively in this study. All patients underwent elective low anterior resection. Peritoneal samples were collected from the abdominal drains at the first, third, and fifth days postoperatively for bacteriological study (quantitative cultures for both aerobes and anaerobes) and cytokines (IL-6, IL-10, TNF) measurement. Patients were divided into two groups: those without symptomatic or clinical evidence of anastomotic leakage (AL; group 1) and those with clinical evidence of AL (group 2). Study variables included hospital stay, wound infection, operative time, blood loss, height of anastomosis, intraperitoneal cytokines, and microbiological study of peritoneal fluid. Clinically evident AL occurred in eight patients (14.3%) and diagnosed postoperatively on median day 6. Intraperitoneal bacterial colonization and cytokine levels were significantly higher in patients with clinical evidence of AL. Wound infection was significantly higher in anastomotic leakage group. The hospital stay for the patients with anastomotic leakage was significantly longer than those without AL (14 ± 1.41 vs. 5.43 ± 0.89 days). A significant difference among two groups was observed regarding operative time, blood loss, blood transfusion, and height of the anastomosis. The peritoneal cytokines levels and intraperitoneal bacterial colonization might be an additional diagnostic tool that can support the decision making of surgeons for early detection of anastomotic leak in colorectal surgery.

  2. Leakage detection device for weld portion

    International Nuclear Information System (INIS)

    Shinkawa, Toshio; Setokuchi, Sadayuki.

    1994-01-01

    The present invention concerns leakage detection device for weld portions, for example, in a nuclear reactor cavity, which can rapidly detect by remote control. That is, a detection device capable of self running and stopping on a guide rail along a weld line is disposed. The detection device comprises a coating mechanism for automatically coating soap water to the weld portion, a vacuum box capable of evacuating the coated surface and a camera for detecting the presence or absence of the soap bubbles generated under the evacuation. Such a device can conduct, by remote control, self running/stopping along with the weld line, coating of the soap water, settling of the vacuum box and confirmation and recording of foaming by using a television monitor. Accordingly, leakage in the weld portion in the reactor cavity or the like can be inspected. As a result, it greatly contributes to improvement of danger upon worker's operation at high place, detection accuracy and reliability of detection and shortening of operation period. (I.S.)

  3. Americium/curium bushing melter drain tests

    International Nuclear Information System (INIS)

    Smith, M.E.; Hardy, B.J.; Smith, M.E.

    1997-01-01

    Americium and curium were produced in the past at the Savannah River Site (SRS) for research, medical, and radiological applications. They have been stored in a nitric acid solution in an SRS reprocessing facility for a number of years. Vitrification of the americium/curium (Am/Cm) solution will allow the material to be safely stored or transported to the DOE Oak Ridge Reservation. Oak Ridge is responsible for marketing radionuclides for research and medical applications. The bushing melter technology being used in the Am/Cm vitrification research work is also under consideration for the stabilization of other actinides such as neptunium and plutonium. A series of melter drain tests were conducted at the Savannah River Technology Center to determine the relationship between the drain tube assembly operating variables and the resulting pour initiation times, glass flowrates, drain tube temperatures, and stop pour times. Performance criteria such as ability to start and stop pours in a controlled manner were also evaluated. The tests were also intended to provide support of oil modeling of drain tube performance predictions and thermal modeling of the drain tube and drain tube heater assembly. These drain tests were instrumental in the design of subsequent melter drain tube and drain tube heaters for the Am/Cm bushing melter, and therefore in the success of the Am/Cm vitrification and plutonium immobilization programs

  4. Anomaly detection using magnetic flux leakage technology

    Energy Technology Data Exchange (ETDEWEB)

    Rempel, Raymond G. [BJ Pipeline Inspection Services, Alberta (Canada)

    2005-07-01

    There are many aspects to properly assessing the integrity of a pipeline. In-line-Inspection (ILI) tools, in particular those that employ the advanced use of Magnetic Flux Leakage (MFL) technology, provide a valuable means of achieving required up-to-date knowledge of a pipeline. More prevalent use of High Resolution MFL In-Line-Inspection tools is growing the knowledge base that leads to more reliable and accurate identification of anomalies in a pipeline, thus, minimizing the need for expensive verification excavations. Accurate assessment of pipeline anomalies can improve the decision making process within an Integrity Management Program and excavation programs can then focus on required repairs instead of calibration or exploratory digs. Utilizing the information from an MFL ILI inspection is not only cost effective but, as well, can also prove to be an extremely valuable building block of a Pipeline Integrity Management Program. (author)

  5. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    reduce the amount of sodium leakage and damage by spilt sodium, the drain system will be remodeled to shorten the drain time; To extinguish a sodium fire in the secondary circuit, a nitrogen gas injection system will be installed; To limit the spread of aerosol, the secondary circuit area will be divided into four smaller zones. These countermeasures will enhance the safety and reliability of the plant with regard to sodium leakage incidents. (author)

  6. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  7. Development of rationalized system treating floor drain

    International Nuclear Information System (INIS)

    Nakamura, Yasuyuki; Serizawa, Kenichi; Komatsu, Akihiro; Shimizu, Takayuki

    1998-01-01

    Radioactive liquid wastes generated at BWR plants are collected and treated as required. These days, however, generation of floor drain has deceased and HFF (Hollow Fiber Filter) has experienced a wide applicability to several kinds of liquid wastes. We should consider that the floor drain can be mixed and diluted with equipment drain and be purified by HFF. That enables some of the sumps and long priming pipes to be combined. From this point of view, we have developed a highly rationalized waste liquid system. We have evaluated the applicability of this system after an investigation into the generation and properties of floor drain and equipment drain at the latest BWR'S and an on-site test at a typical BWR. (author)

  8. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount of arbitr......Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount...

  9. A retrospective analysis of endoscopic treatment outcomes in patients with postoperative bile leakage.

    Science.gov (United States)

    Sayar, Suleyman; Olmez, Sehmus; Avcioglu, Ufuk; Tenlik, Ilyas; Saritas, Bunyamin; Ozdil, Kamil; Altiparmak, Emin; Ozaslan, Ersan

    2016-01-01

    Bile leakage, while rare, can be a complication seen after cholecystectomy. It may also occur after hepatic or biliary surgical procedures. Etiology may be underlying pathology or surgical complication. Endoscopic retrograde cholangiopancreatography (ERCP) can play major role in diagnosis and treatment of bile leakage. Present study was a retrospective analysis of outcomes of ERCP procedure in patients with bile leakage. Patients who underwent ERCP for bile leakage after surgery between 2008 and 2012 were included in the study. Etiology, clinical and radiological characteristics, and endoscopic treatment outcomes were recorded and analyzed. Total of 31 patients (10 male, 21 female) were included in the study. ERCP was performed for bile leakage after cholecystectomy in 20 patients, after hydatid cyst operation in 10 patients, and after hepatic resection in 1 patient. Clinical signs and symptoms of bile leakage included abdominal pain, bile drainage from percutaneous drain, peritonitis, jaundice, and bilioma. Twelve (60%) patients were treated with endoscopic sphincterotomy (ES) and nasobiliary drainage (NBD) catheter, 7 patients (35%) were treated with ES and biliary stent (BS), and 1 patient (5%) was treated with ES alone. Treatment efficiency was 100% in bile leakage cases after cholecystectomy. Ten (32%) cases of hydatid cyst surgery had subsequent cystobiliary fistula. Of these patients, 7 were treated with ES and NBD, 2 were treated with ES and BS, and 1 patient (8%) with ES alone. Treatment was successful in 90% of these cases. ERCP is an effective method to diagnose and treat bile leakage. Endoscopic treatment of postoperative bile leakage should be individualized based on etiological and other factors, such as accompanying fistula.

  10. Development of dual field magnetic flux leakage (MFL) inspection technology to detect mechanical damage.

    Science.gov (United States)

    2013-03-01

    This report details the development and testing of a dual magnetization in-line inspection (ILI) : tool for detecting mechanical damage in operating pipelines, including the first field trials of a : fully operational dual-field magnetic flux leakage...

  11. 216-Z-8 French drain characterization study

    International Nuclear Information System (INIS)

    Marratt, M.C.; Kasper, R.B.; Van Luik, A.E.

    1984-09-01

    The 216-Z-8 French drain study is one of a series of studies examining historical transuranic waste facilities no longer in use at the Hanford Site. The 216-Z-8 French drain underground disposal system consisted of a large settling tank that overflowed into a French drain. The French drain consisted of two large-diameter, gravel filled, vitrified clay pipes placed on end, end-to-end, over a gravel-filled excavation. The top of the drain was sealed with concrete to prevent the upward flow of waste solution. The waste solution discharged to the 216-Z-8 waste disposal system was a neutralized, transuranic recovery process, filter cake, backflush slurry. The primary objective of this study was to determine the distribution of plutonium and americium beneath the French drain. Transuranic activity under the French drain did not exceed 5 nCi/g in the soil samples obtained from a well within 1 m of the drain structure. Conservative estimates indicated that 4 to 5 m 3 of radioactive contaminated sediments, 10 nCi/g may lie directly under the 216-Z-8 French drain. The secondary objective of the study was to evaluate the possibility of a leak in the settling tank. Results from the analysis of soil samples from wells drilled around the settling tank indicated the presence of low-level transuranic contamination (on the order of 0.001 nci/g) in the soil surrounding the tank. However, the distribution of the contamination does not support a leak as a plausible mechanism to account for the observed activity surrounding the tank. The bulk of the plutonium was confirmed to be in the sludge that remained in the tank; thus, no significant environmental impact would be expected even if there has been a leak

  12. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  13. Study of radiation-induced leakage current between adjacent devices in a CMOS integrated circuit

    Institute of Scientific and Technical Information of China (English)

    Ding Lili; Guo Hongxia; Chen Wei; Fan Ruyu

    2012-01-01

    Radiation-induced inter-device leakage is studied using an analytical model and TCAD simulation.There were some different opinions in understanding the process of defect build-up in trench oxide and parasitic leakage path turning on from earlier studies.To reanalyze this problem and make it beyond argument,every possible variable is considered using theoretical analysis,not just the change of electric field or oxide thickness independently.Among all possible inter-device leakage paths,parasitic structures with N-well as both drain and source are comparatively more sensitive to the total dose effect when a voltage discrepancy exists between the drain and source region.Since N-well regions are commonly connected to the same power supply,these kinds of structures will not be a problem in a real CMOS integrated circuit.Generally speaking,conduction paths of inter-device leakage existing in a real integrated circuit and under real electrical circumstances are not very sensitive to the total ionizing dose effect.

  14. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    Directory of Open Access Journals (Sweden)

    Ayhan GENCLER

    2009-07-01

    Full Text Available Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems that, in general, developing or underdeveloped countries experience the negative consequences of the brain drain and suffer from the decreases in their human capital. The paper explains the phenomenon of skilled international migration, or brain drain, and summarizes the main global trends in this area.

  15. Accurate characterization of organic thin film transistors in the presence of gate leakage current

    Directory of Open Access Journals (Sweden)

    Vinay K. Singh

    2011-12-01

    Full Text Available The presence of gate leakage through polymer dielectric in organic thin film transistors (OTFT prevents accurate estimation of transistor characteristics especially in subthreshold regime. To mitigate the impact of gate leakage on transfer characteristics and allow accurate estimation of mobility, subthreshold slope and on/off current ratio, a measurement technique involving simultaneous sweep of both gate and drain voltages is proposed. Two dimensional numerical device simulation is used to illustrate the validity of the proposed technique. Experimental results obtained with Pentacene/PMMA OTFT with significant gate leakage show a low on/off current ratio of ∼ 102 and subthreshold is 10 V/decade obtained using conventional measurement technique. The proposed technique reveals that channel on/off current ratio is more than two orders of magnitude higher at ∼104 and subthreshold slope is 4.5 V/decade.

  16. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  17. Subsea Hydraulic Leakage Detection and Diagnosis

    OpenAIRE

    Stavenes, Thomas

    2010-01-01

    The motivation for this thesis is reduction of hydraulic emissions, minimizing of process emergency shutdowns, exploitation of intervention capacity, and reduction of costs. Today, monitoring of hydraulic leakages is scarce and the main way to detect leakage is the constant need for filling of hydraulic fluid to the Hydraulic Power Unit (HPU). Leakage detection and diagnosis has potential, which would be adressed in this thesis. A strategy towards leakage detection and diagnosis is given....

  18. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  19. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  20. Drain Back, Low Flow Solar Combi Systems

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2014-01-01

    Drain Back systems with ETC collectors are tested and analyzed in a Danish - Chinese cooperation project. Experiences from early work at DTU, with drain back, low flow systems, was used to design two systems: 1) One laboratory system at DTU and 2) One demonstration system in a single family house...... in Sorö Denmark. Detailed monitoring and modelling of the system in the DTU lab is done to be able to generalize the results, to other climates and loads and to make design optimizations. The advantage with drain back, low flow systems, is that the system can be made more simple with less components...... and that the performance can be enhanced. A combination of the drain back- and system expansion vessel was tested successfully. Small initial problems with installation and proposals for design improvements to avoid these in practice are described in the paper. Installer education and training is an important step to have...

  1. Prefabricated vertical drains, vol. I : engineering guidelines.

    Science.gov (United States)

    1986-09-01

    This volume presents procedures and guidelines applicable to the design and instal : tion of prefabricated vertical drains to accelerate consolidation of soils. The : contents represent the Consultant's interpretation of the state-of-the-art as of : ...

  2. Penrose Drain Migration After Laparoscopic Surgery

    Directory of Open Access Journals (Sweden)

    Pazouki AbdolReza

    2009-05-01

    Full Text Available Laparoscopy has made a revolution in surgical procedures and treatment of various diseases but its complications are still under investigation. Intra-abdominal visceral and vessel injuries, trocar site hernia, and leaving foreign bodies into the peritoneal cavity are among some laparoscopic surgery complications. This is a rare report of Penrose drain migration following incomplete laparoscopic Fundoplication surgery. The patient was a 47- year- old woman, who was a candidate for Touplet Fundoplication via laparoscopic approach due to refractory gastro-esophageal reflux disease (GERD. While wrapping a Penrose drain around the esophagus, the patient had a cardiorespiratory arrest. Attempts to remove the Penrose drain were unsuccessful and the surgical procedure was terminated due to patient's condition. Four months later, after a long period of dysphagia and abdominal pain, the Penrose drain was defecated via rectum.

  3. Brain drain of China and India

    OpenAIRE

    Li, Yuan

    2012-01-01

    Abstract Under the background of globalization, brain drain is a common phenomenon in many countries. Talents flow from developing countries to developed countries, and this phenomenon unavoidably exerts various and profound influences to both the source countries and the receiving countries. This thesis deals with the phenomenon of brain drain with the aim to investigate the phenomenon further and carry out two case studies of China and India. The research method is main...

  4. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  5. How to remove a chest drain.

    Science.gov (United States)

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  6. Effect of drains on the seepage of contaminants from subgrade tailings disposal areas

    International Nuclear Information System (INIS)

    Witten, A.J.; Pin, F.G.; Sharp, R.D.

    1984-01-01

    A numerical simulation study is performed to investigate the influence of ponded water and a bottom drain on the pathways for contaminant migration from a subgrade uranium mill tailings disposal pit. A numerical model is applied to a generic disposal pit constructed with a bottom clay liner and steep unlined sidewalls. The migration of a two-contaminant system is modeled assuming that neither contaminant decays and only one contaminant is retarded. Two dominant pathways are identified; one associated with lateral sidewall leakage and the other associated with transport through the bottom clay liner. It is found that the drain serves to reduce migration through the sidewall which, in turn, prevents the retarded contaminant from reaching the aquifer. The ponded water provides increased head which causes an accelerated vertical movement of moisture through the clay liner. 2 references, 8 figures

  7. Noise performance in AlGaN/GaN HEMTs under high drain bias

    International Nuclear Information System (INIS)

    Pang Lei; Pu Yan; Lin Xinyu; Wang Liang; Liu Jian

    2009-01-01

    The advent of fully integrated GaN PA-LNA circuits makes it meaningful to investigate the noise performance under high drain bias. However, noise performance of AlGaN/GaN HEMTs under high bias has not received worldwide attention in theoretical studies due to its complicated mechanisms. The noise value is moderately higher and its rate of increase is fast with increasing high voltage. In this paper, several possible mechanisms are proposed to be responsible for it. Impact ionization under high electric field incurs great fluctuation of carrier density, which increases the drain diffusion noise. Besides, higher gate leakage current related shot noise and a more severe self-heating effect are also contributors to the noise increase at high bias. Analysis from macroscopic and microscopic perspectives can help us to design new device structures to improve noise performance of AlGaN/GaN HEMTs under high bias. (semiconductor devices)

  8. The effect of drains on the seepage of contaminants from subgrade tailings disposal areas

    International Nuclear Information System (INIS)

    Witten, A.J.; Pin, F.G.; Sharp, R.D.

    1984-01-01

    A numerical simulation study is performed to investigate the influence of ponded water and a bottom drain on the pathways for contaminant migration from a subgrade uranium mill tailings disposal pit. A numerical model is applied to a generic disposal pit constructed with a bottom clay liner and steep unlined sidewalls. The migration of a two-contaminant system is modeled assuming that neither contaminant decays and only one contaminant is retarded. Two dominant pathways are indentified; one associated with lateral sidewall leakage and the other associated with transport through the bottom clay liner. It is found that the drain serves to reduce migration through the sidewall which, in turn, prevents the retarded contaminant from reaching the aquifer. The ponded water provides increased head which causes an accelarated vertical movement of moisture through the clay liner

  9. Mechanical decontamination techniques for floor drain systems

    International Nuclear Information System (INIS)

    Palau, G.L.

    1987-01-01

    The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used

  10. Anastomotic leakage after low anterior resection for rectal cancer. Facts, obscurity, and fiction

    International Nuclear Information System (INIS)

    Taflampas, P.; Christodoulakis, M.; Tsiftsis, D.D.

    2009-01-01

    The subject of anastomotic leakage after low anterior resection (LAR) for rectal cancer remains controversial. Risk factors have been discussed in several studies but the findings are often inconclusive. This review evaluates these studies and separates the known risk factors into those that are well documented, those that are obsolete, and those that require further research. We searched the Medline and PubMed databases using the keywords: leakage,' 'low anterior resection,' 'rectal cancer,' 'risk factors,' and their combinations. There were no language or publication year restrictions. References in published papers were also reviewed. Each risk factor was evaluated and discussed separately. The evidence suggests that low anastomoses are more prone to leakage. Other well-documented risk factors are male sex, smoking, and preoperative malnutrition. Routine mobilization of the splenic flexure and the use of a J-pouch seem to reduce the leakage rate. The effect of preoperative chemo-radiotherapy is under scrutiny. The indications for a protective stoma remain debatable. Omentoplasty, bowel preparation, the use of a drain, and tumor stage do not seem to affect the leakage rate. The type of operation (open or laparoscopic) and anastomosis (hand-sewn or stapled) is not crucial. (author)

  11. Monitoring device for radioactive leakage from steam system in nuclear power plant

    International Nuclear Information System (INIS)

    Ogawa, Tateo; Sato, Kohei

    1988-01-01

    Purpose: To improve the reliability for the monitor of radio-active leakage by accumulating small quantity of radioactivities each lower than the detectable level and increasing their dose rate. Constitution: Even if the steam system radiation monitor in the nuclear power plant is disposed for the detection of in-leak radioactivity, radioactive leakage can be monitored at high reliability by increasing the small quantity of radioactivities in the drains to a detectable sensitivity range of the monitor upon detection. In view of the above, in the present invention, radioactive material catching medium is incorporated to a radio-activity monitor spool piece for accumulating small quantity of radioactivities. Specifically as the catching medium, an ion exchange resin is used for the leakage of ionic radioactive material, while an ion exchange resin increased with the mixing ratio of a cationic resin or hollow thread membrane filter is used for crud-like radioactive material leakage. These catching media are incorporated into the spool piece, thereby enabling to catch even small quantity of radioactive leakage lower than the detectable sensitivity of the radiation monitor, if should occur, in the spool piece and enabling radioactive detection for the accumulated dose rate. (Horiuchi, T.)

  12. 21 CFR 868.5995 - Tee drain (water trap).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  13. Fibredrain method. Environmentally friendly vertical drain; Fiberdrain koho. Kankyo ni yasashii vertical drain koho

    Energy Technology Data Exchange (ETDEWEB)

    Suto, Y.; Inoue, T. [Fukken Co. Ltd., Hiroshima (Japan); Miura, N. [Saga University, Saga (Japan). Faculty of Science and Engineering; Yoshida, Y.; Hamada, K. [Hiroshima Prefectural Government Office, Hiroshima (Japan); Aboshi, H. [Hiroshima University, Hiroshima (Japan)

    1997-11-01

    Ground improvement using fibredrain (FD) material has not been used in Japan. For its practical use in Japan, laboratory experiment was made on such technological characteristics of FD material as tensile strength and permeability, and field test was also made to verify its improvement effect. A plane FD specimen of nearly 90mm wide and 9mm thick is composed of a folded double jute fabrics band and 4 twisted coir ropes arranged between the jute fabrics at even intervals, and the band is sewn up along center lines between the ropes. A mean permeability coefficient is estimated to be {kappa} = 1.0times10{sup -1}cm/s and {kappa} = 1.0times10{sup -2}cm/s at {sigma}{sup 3} = 0.5kgf/cm{sup 2} and {sigma}{sup 3} = 2.0kgf/cm{sup 2} in lateral pressure, respectively, showing sufficient permeabilities for vertical drain material. The tensile strength of fresh FD material is estimated to be a little stronger than 900kg/material width which is far stronger than that of conventional FD materials. The field test result showed that the FD material achieved the target for ground improvement, and has sufficient functions as a substitute for SD material. 6 refs., 10 figs.

  14. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  15. FROM BRAIN DRAIN TO BRAIN NETWORKING

    Directory of Open Access Journals (Sweden)

    Irina BONCEA

    2015-06-01

    Full Text Available Scientific networking is the most accessible way a country can turn the brain drain into brain gain. Diaspora’s members offer valuable information, advice or financial support from the destination country, without being necessary to return. This article aims to investigate Romania’s potential of turning brain drain into brain networking, using evidence from the medical sector. The main factors influencing the collaboration with the country of origin are investigated. The conclusions suggest that Romania could benefit from the diaspora option, through an active implication at institutional level and the implementation of a strategy in this area.

  16. A transformerless single-phase symmetrical Z-source HERIC inverter with reduced leakage currents for PV systems

    DEFF Research Database (Denmark)

    Li, Kerui; Shen, Yanfeng; Yang, Yongheng

    2018-01-01

    and thus low leakage currents in PV applications. The symmetric Z-source HERIC inverter requires two extra active switches. Nevertheless, the operation frequency of the two switches is the line frequency, leading to negligible losses. More importantly, the performance in terms of low leakage currents...... and harmonics is improved. Experimental tests are performed to validate the analysis and performance of the proposed system....

  17. Why the CDM can reduce carbon leakage

    International Nuclear Information System (INIS)

    Kallbekken, S.

    2006-04-01

    Carbon leakage is an important concern because it can reduce the environmental effectiveness of the Kyoto Protocol. The Clean Development Mechanism, one of the flexibility mechanisms allowed under the protocol, has the potential to reduce carbon leakage significantly because it reduces the relative competitive disadvantage to Annex B countries of restricting greenhouse gas emissions. The economic intuition behind this mechanism is explored in a theoretical analysis. It is then analyzed numerically using a CGE model. The results indicate that, assuming appropriate accounting for leakage and under realistic assumptions on CDM activity, the CDM has the potential to reduce the magnitude of carbon leakage by around three fifths

  18. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  19. Negative charging effect of traps on the gate leakage current of an AlGaN/GaN HEMT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. J.; Lim, J. H.; Yang, J. W. [Chonbuk National University, Jeonju (Korea, Republic of); Stanchina, W. [University of Pittsburgh, Pittsburgh, PA (United States)

    2014-08-15

    The negative charging effect of surface traps on the gate leakage current of AlGaN/GaN high electron mobility transistors (HEMTs) was investigated. The gate leakage current could be decreased by two orders of magnitude by using a photo-electrochemical process to treat of the source and the drain region, but current flowed into the gate even at a negative voltage in a limited region when the measurement was executed with a gate voltage sweep from negative to positive voltage. Also the electrical characteristics of the HEMT were degraded by pulsed operation of the gate. Traps newly generated on the surface were regarded as sources for the current that flowed against the applied voltage, and the number of traps was estimated. Also, a slow transient in the drain current was confirmed based on the results of delayed sweep measurements.

  20. Leakage of colon anastomoses: development of an experimental model in pigs

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Sørensen, Michael

    2007-01-01

    model has only been developed in one gastric bypass study. The aim of the present study was to develop a leakage model of pig colon anastomoses. This type of study has never been performed before. Materials and Methods: Anastomosis was performed in 22 pigs. In all anastomoses a standardized rupture......: A model of anastomotic leakage on pig colon is developed with creation of a 21-mm rupture in the anastomotic line....

  1. Uncertainty and risk assessment of leakage in water tunnels - a case from Nepal Himalaya

    OpenAIRE

    Panthi, Krishna Kanta; Nilsen, Bjørn

    2008-01-01

    Safety and stability are the key issues in underground excavations. Making tunnels water tight plays an important role in this regards. Water leakage problems in unlined or shotcrete lined water tunnels are not new issues. In many occasions severe water inflow as well as leakage problems have been faced that not only reduced stability of the rock mass surrounding the tunnel, but also valuable water has been lost from it, causing safety risk as well as huge economic loss to the projects. I...

  2. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    OpenAIRE

    Ayhan GENCLER

    2009-01-01

    Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems tha...

  3. The European Politics of Brain Drain

    DEFF Research Database (Denmark)

    Hasselbalch, Jacob

    This qualitative multi-method studymaps the politics of brain drain at the level of the European Union and follows the evolution of the issue over the last four parliamentary periods. By utilizing a novel combination of interviews with a content and network analysis of parliamentary questions...

  4. Forest Carbon Leakage Quantification Methods and Their Suitability for Assessing Leakage in REDD

    Directory of Open Access Journals (Sweden)

    Sabine Henders

    2012-01-01

    Full Text Available This paper assesses quantification methods for carbon leakage from forestry activities for their suitability in leakage accounting in a future Reducing Emissions from Deforestation and Forest Degradation (REDD mechanism. To that end, we first conducted a literature review to identify specific pre-requisites for leakage assessment in REDD. We then analyzed a total of 34 quantification methods for leakage emissions from the Clean Development Mechanism (CDM, the Verified Carbon Standard (VCS, the Climate Action Reserve (CAR, the CarbonFix Standard (CFS, and from scientific literature sources. We screened these methods for the leakage aspects they address in terms of leakage type, tools used for quantification and the geographical scale covered. Results show that leakage methods can be grouped into nine main methodological approaches, six of which could fulfill the recommended REDD leakage requirements if approaches for primary and secondary leakage are combined. The majority of methods assessed, address either primary or secondary leakage; the former mostly on a local or regional and the latter on national scale. The VCS is found to be the only carbon accounting standard at present to fulfill all leakage quantification requisites in REDD. However, a lack of accounting methods was identified for international leakage, which was addressed by only two methods, both from scientific literature.

  5. Comparative investigation of novel hetero gate dielectric and drain engineered charge plasma TFET for improved DC and RF performance

    Science.gov (United States)

    Yadav, Dharmendra Singh; Verma, Abhishek; Sharma, Dheeraj; Tirkey, Sukeshni; Raad, Bhagwan Ram

    2017-11-01

    Tunnel-field-effect-transistor (TFET) has emerged as one of the most prominent devices to replace conventional MOSFET due to its ability to provide sub-threshold slope below 60 mV/decade (SS ≤ 60 mV/decade) and low leakage current. Despite this, TFETs suffer from ambipolar behavior, lower ON-state current, and poor RF performance. To address these issues, we have introduced drain and gate work function engineering with hetero gate dielectric for the first time in charge plasma based doping-less TFET (DL TFET). In this, the usage of dual work functionality over the drain region significantly reduces the ambipolar behavior of the device by varying the energy barrier at drain/channel interface. Whereas, the presence of dual work function at the gate terminal increases the ON-state current (ION). The combined effect of dual work function at the gate and drain electrode results in the increment of ON-state current (ION) and decrement of ambipolar conduction (Iambi) respectively. Furthermore, the incorporation of hetero gate dielectric along with dual work functionality at the drain and gate electrode provides an overall improvement in the performance of the device in terms of reduction in ambipolarity, threshold voltage and sub-threshold slope along with improved ON-state current and high frequency figures of merit.

  6. Remote laser detection of natural gas leakages from pipelines

    International Nuclear Information System (INIS)

    Petukhov, V O; Gorobets, V A; Andreev, Yu M; Lanskii, G V

    2010-01-01

    A differential absorption lidar based on a tunable TEA CO 2 laser emitting at 42 lines of the 'hot' 01 1 1 - 11 1 0 band in the range from 10.9 to 11.4 μm is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h -1 and a probe pulse repetition rate of 5 Hz. (laser applications and other topics in quantum electronics)

  7. Model-Based Detection of Pipe Leakage at Joints

    International Nuclear Information System (INIS)

    Kim, Taejin; Youn, Byeng D.; Woo, Sihyong

    2015-01-01

    Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found

  8. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  9. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  10. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Griffiths, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  11. A Rare Complication of Abdominal Drain: Fallopian Tube Herniation Through the Drain Site

    Directory of Open Access Journals (Sweden)

    Dilek Uygur

    2016-05-01

    Full Text Available Prophylactic drainage of the peritoneal cavity after obstetrical and gynecological surgery is widely practiced. The idea of “when in doubt, drain” is accepted and applied clinically by many surgeons. However, surgically placed drains are not without risk. The present case describes herniation of fallopian tube during the removal of a surgical drain placed after a cesarean section.

  12. A Rare Complication of Abdominal Drain: Fallopian Tube Herniation Through the Drain Site

    OpenAIRE

    Dilek Uygur; Seval Erdinç; Hülya Dede; Ümit Taşdemir; Oktay Kaymak; Nuri Danışman

    2016-01-01

    Prophylactic drainage of the peritoneal cavity after obstetrical and gynecological surgery is widely practiced. The idea of “when in doubt, drain” is accepted and applied clinically by many surgeons. However, surgically placed drains are not without risk. The present case describes herniation of fallopian tube during the removal of a surgical drain placed after a cesarean section.

  13. The value of cholangiography through Jackson-Pratt drains in the management of postoperative biliary injuries.

    Science.gov (United States)

    Macedo, Francisco Igor B; Casillas, Victor J; Davis, James S; Levi, Joe U; Sleeman, Danny

    2014-01-01

    Iatrogenic biliary injury is the most significant complication after laparoscopic cholecystectomy. We present our experience with an alternative diagnostic approach using transcatheter cholangiography (TCC) through a Jackson-Pratt (JP) drain and discuss potential benefits and limitations of the technique. From March 2002 to February 2012, 40 patients with major postoperative biliary injury underwent biliary reconstruction at our institution. Mean age was 51.7 ± 18.1 years (range, 19 to 86 years) with 30 (75%) females. Seventeen (42.5%) injuries were detected intraoperatively and in 13 (32.5%) cases, JP drains were placed for biliary drainage. Lesions were classified according to Bismuth grade: I (10 patients [25%]), II (10 patients [25%]), III (six patients [15%]), IV (10 patients [25%]), and V (four patients [10%]). TCC was performed in seven patients with JP drains (53.8%). It fully defined the injury site in three cases of limited magnetic resonance cholangiopancreatography (MRCP) such as common hepatic duct and common bile duct leaks and in four cases (57.1%) that endoscopic retrograde cholangiopancreatography (ERCP) was limited as a result of clipping of the distal common bile duct. TCC showed promising results in cases of limited MRCP and ERCP such as fistulous orifices or leakage. It may represent an alternative adjunct in the diagnostic armamentarium of complex biliary injuries.

  14. Drain Current Modulation of a Single Drain MOSFET by Lorentz Force for Magnetic Sensing Application.

    Science.gov (United States)

    Chatterjee, Prasenjit; Chow, Hwang-Cherng; Feng, Wu-Shiung

    2016-08-30

    This paper reports a detailed analysis of the drain current modulation of a single-drain normal-gate n channel metal-oxide semiconductor field effect transistor (n-MOSFET) under an on-chip magnetic field. A single-drain n-MOSFET has been fabricated and placed in the center of a square-shaped metal loop which generates the on-chip magnetic field. The proposed device designed is much smaller in size with respect to the metal loop, which ensures that the generated magnetic field is approximately uniform. The change of drain current and change of bulk current per micron device width has been measured. The result shows that the difference drain current is about 145 µA for the maximum applied magnetic field. Such changes occur from the applied Lorentz force to push out the carriers from the channel. Based on the drain current difference, the change in effective mobility has been detected up to 4.227%. Furthermore, a detailed investigation reveals that the device behavior is quite different in subthreshold and saturation region. A change of 50.24 µA bulk current has also been measured. Finally, the device has been verified for use as a magnetic sensor with sensitivity 4.084% (29.6 T(-1)), which is very effective as compared to other previously reported works for a single device.

  15. Carbon accumulation in pristine and drained mires

    Energy Technology Data Exchange (ETDEWEB)

    Maekilae, M.

    2011-07-01

    The carbon accumulation of 73 peat columns from 48 pristine and drained mires was investigated using a total of 367 dates and age-depth models derived from bulk density measurements. Peat columns were collected from mires of varying depth, age, degree of natural state and nutrient conditions in aapa mire and raised bog regions and coastal mires from southern and central Finland and Russian Karelia. Particular attention was paid to the accumulation of carbon over the last 300 years, as this period encompasses the best estimates of the oxic layer (acrotelm) age across the range of sites investigated. In general, drained mires are initially more nutrient-rich than pristine mires. Organic matter decomposes more rapidly at drained sites than at pristine sites, resulting in thinner peat layers and carbon accumulation but a higher dry bulk density and carbon content. The average carbon accumulation was calculated as 24.0 g m-2 yr-1 at pristine sites and 19.4 g m-2 yr-1 at drained sites, while for peat layers younger than 300 years the respective figures were 45.3 and 34.5 g m-2 yr-1 at pristine and drained sites. For the <300-year-old peat layers studied here, the average thickness was 19 cm less and the carbon accumulation rate 10.8 g m-2 yr-1 lower in drained areas than in pristine areas. The amount carbon accumulation of surface peat layers depends upon the mire site type, vegetation and natural state; variations reflect differences in plant communities as well as factors that affect biomass production and decay rates. The highest accumulation rates and thus carbon binding for layers younger than 300 years were measured in the ombrotrophic mire site types (Sphagnum fuscum bog and Sphagnum fuscum pine bog), and the second highest rates in wet, treeless oligotrophic and minerotrophic mire site types. The lowest values of carbon accumulation over the last 300 years were obtained for the most transformed, sparsely forested and forested mire site types, where the water

  16. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  17. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  18. Processing method of radioactive cleaning drain

    International Nuclear Information System (INIS)

    Otsuka, Shigemitsu; Murakami, Tadashi; Kitao, Hideo

    1998-01-01

    Upon processing of radioactive cleaning drains, contained Co-60 is removed by a selectively adsorbing adsorbent. In addition, after removing suspended materials by a filtering device, Co-60 as predominant nuclides in the drain is selectively adsorbed. The concentration of objective Co-60 is in the order of 0.1 Bq/cc, and non-radioactive metal ions such as Na + ions are present in the order of ppm in addition to Co-60. A granular adsorbent for selectively adsorbing Co-60 is oxine-added activated carbon, and has a grain size of from 20 to 48 mesh. The granular adsorbent is used while being filled in an adsorbing tower. Since a relatively simple device comprising the filtering device and the adsorbing tower in combination is provided, the reduction of the construction cost can be expected. In addition, since no filtering aid is used in the filtering device, the amount of secondary wastes is small. (N.H.)

  19. Percutaneous Retrieval of a Retained Jackson-Pratt Drain Fragment

    International Nuclear Information System (INIS)

    Namyslowski, Jan; Halin, Neil J.; Greenfield, Alan J.

    1996-01-01

    A retained intraabdominal Jackson-Pratt drain fragment was percutaneously retrieved using an inflated angioplasty balloon that had been maneuvered inside of the drain lumen over a hydrophilic-coated steerable guidewire

  20. Device for discharging drain in a control rod driving apparatus

    International Nuclear Information System (INIS)

    Ikeda, Tadasu; Ikuta, Takuzo; Yoshida, Tomiji; Tsukahara, Katsumi.

    1975-01-01

    Object: To efficiently and safely collect and discharge drain by a simple construction in which a drain cover and a drain tank in a control rod driving apparatus are integrally formed, and an overhauling wrench of said apparatus and a drain hose are mounted on the drain tank. Structure: When a mounting bolt is untightened by a torque wrench so as to be removed from a flange surface of the control rod driving apparatus in a nuclear reactor, axial movement of said apparatus is absorbed by a spring so that drain containing a radioactive material is discharged into a drain tank through the flange surface of said apparatus and is then guided into a collecting tank through a drain hose. (Kamimura, M.)

  1. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  2. Water Table Recession in Subsurface Drained Soils

    OpenAIRE

    Moustafa, Mahmoud Mohamed; Yomota, Atsushi

    1999-01-01

    Theoretical drainage equations are intensively tested in many parts of humid and arid regions and are commonly used in drainage design. However, this is still a great concern in Japan as the drainage design is exclusively based on local experiences and empirical basis. There is a need therefore to evaluate the theoretical drainage equations under Japanese field conditions to recommend equations for design of subsurface drainage systems. This was the main motivation for this study. While drain...

  3. Drained Triaxial Tests on Eastern Scheldt Sand

    DEFF Research Database (Denmark)

    Praastrup, U.; Jakobsen, Kim Parsberg

    In the process of understanding and developing models for geomaterials, the stress-strain behaviour is commonly studied by performing triaxial tests. In the present study static triaxial tests have been performed to gain knowledge of the stress-strain behaviour of frictional materials during...... monotonic loading. The tests reported herein are all drained tests, starting from different initial states of stress and following various stress paths. AIl the tests are performed on reconstituted medium dense specimens of Eastern Scheldt Sand....

  4. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    OpenAIRE

    Gencler, Ayhan

    2009-01-01

    Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems that, in general, developing or underdeveloped...

  5. Brain drain: Propulsive factors and consequences

    Directory of Open Access Journals (Sweden)

    Dragan ILIC

    2018-01-01

    Full Text Available When speaking about the total number of highly educated individuals’ migration, it is easy to spot that it is rapidly increasing. The brain drain issues should be taken very seriously especially in under developed and in the developing countries, knowing that the human capital is globally mobile and that highly educated individuals can without any issues market their knowledge around the globe. Dealing with it requires a carefully tailored strategy for these countries, which are suffering from severe human capital losses on annual basis. Since the labor markets of today are highly competitive, it is necessary for these countries to secure good advancement and doing business opportunities. The purpose of this research is to provide an insight into the key propulsive factors and potential consequences caused by the brain drain. The method used in order to conduct the research was a carefully designed questionnaire taken by the date subject enrolled at the third and fourth years of state governed and privately owned universities. This research shows that one of the key reasons for brain drain in underdeveloped and in the developing countries is shortage of further educational advancement opportunities.

  6. Fallopian Tube Herniation: An Unusual Complication of Surgical Drain

    OpenAIRE

    Sharma, Lipi; Singh, Alpana; Bhaskaran, Sruthi; Radhika, A. G.; Radhakrishnan, Gita

    2012-01-01

    Background. Surgical drains have been used since time immemorial, but their use is not without complications. By presenting this case we aim to describe an uncommon complication of herniation of fallopian tube following the simple procedure of surgical drain removal. Case Presentation. This case describes a 23-year G2P1L1 who underwent an emergency cesarean section for obstructed labor with intraperitoneal drain insertion. The patient had an uneventful postoperative period, drain was removed ...

  7. Fallopian Tube Herniation through Left Sided Abdominal Drain Site.

    Science.gov (United States)

    Hussain, Khalid; Masood, Jovaria

    2016-06-01

    Intra-abdominal drains have been used since long to prevent intra-abdominal collection, and detect any anastomotic leaks. We report a case of left sided fallopian tube herniation from a left lower abdominal drain site in a 27-year female who underwent caesarian section for breach presentation. Several complications related to drain usage has been described but left sided fallopian tube prolapse through drain site has not been reported in literature.

  8. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... and returns its result. Almost independently of secure computation, the area of {\\em leakage resilient cryptography} has recently been evolving intensively, studying the question of designing cryptographic primitives that remain secure even when some information about the secret key is leaked. In this paper...

  9. Environmental and artificial tracers for investigating leakages into salt mines

    International Nuclear Information System (INIS)

    Zuber, A.; Grabczak, J.; Kolonko, M.

    1979-01-01

    The paper presents the results of five years of experience in investigating the origin of waters in the Wapno mine, where salt is exploited in a Zechstein dome, in northwestern Poland. Tritium and 14 C measurements showed young infiltration waters in leakages at the third level of the mine. Stable isotope determinations showed a considerable shift of values from the precipitation line, both on activity and on concentration scales. Despite this shift, it was possible to distinguish infiltration waters from connate ones appearing at deeper mine levels. In 1976 and 1977 leakage flow-rates increased and the mineralization decreased. Tritium and 14 C contents did not then change, showing that, at the initial stages of flooding, the origin of water in the leakages was not changed. The first results of isotope investigations in the Klodawa mine, situated in another Zechstein salt dome in central Poland, showed connate waters. Observations performed in the Wieliczka salt mine, situated in Miocene formations in southern Poland, showed old waters originating from the surrounding formations. Their stable isotope composition shows that recharge took place in a cooler climate. The 14 C content of these waters is 1 to 2% of recent carbon. The experimental procedure used to determine the isotopic composition of highly mineralized brines is also described. (author)

  10. MEDICAL BRAIN DRAIN - A THEORETICAL APPROACH

    Directory of Open Access Journals (Sweden)

    Boncea Irina

    2013-07-01

    Full Text Available Medical brain drain is defined as the migration of health personnel from developing countries to developed countries and between industrialized nations in search for better opportunities. This phenomenon became a global growing concern due to its impact on both the donor and the destination countries. This article aims to present the main theoretical contributions starting from 1950 until today and the historical evolution, in the attempt of correlating the particular case of medical brain drain with the theory and evolution of the brain drain in general. This article raises questions and offers answers, identifies the main issues and looks for possible solutions in order to reduce the emigration of medical doctors. Factors of influence include push (low level of income, poor working conditions, the absence of job openings and social recognition, oppressive political climate and pull (better remuneration and working conditions, prospects for career development, job satisfaction, security factors. Developing countries are confronting with the loss of their most valuable intellectuals and the investment in their education, at the benefit of developed nations. An ethical debate arises as the disparities between countries increases, industrialized nations filling in the gaps in health systems with professionals from countries already facing shortages. However, recent literature emphasizes the possibility of a “beneficial brain drain” through education incentives offered by the emigration prospects. Other sources of “brain gain” for donor country are the remittances, the scientific networks and return migration. Measures to stem the medical brain drain involve the common effort and collaboration between developing and developed countries and international organizations. Measures adopted by donor countries include higher salaries, better working conditions, security, career opportunities, incentives to stimulate return migration. Destination

  11. Design and construction of a French drain for groundwater diversion in solid waste storage area six at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Davis, E.C.; Stansfield, R.G.

    1984-05-01

    Engineering modifiations or engineered barriers have been suggested as a possible means of improving the performance of low-level waste disposal sites located in the humid eastern United States. Design and construction of a passive French drain, located in Solid Waste Storage Area No. 6 at the Oak Ridge National Laboratory. The drain was designed to hydrologically isolate a 0.44-ha area that contains a group of 49 low-level waste trenches by separating it from upgradient groundwater recharge areas. The 252-m drain (maximum depth = 9 m) that surrounds the group of trenches on the north and east sides was excavated, lined with filter fabric, backfilled with crushed stone, and covered with a 0.6 m layer of excavated material at an estimated cost of $153,000. Of the 17 days it took to complete the work, about 5 days were spent excavating sidewall slide material that fell into the drain during excavation. Photography of the drain wall revealed the contorted structure of the weathered shale, which was responsible for many of the slides. Monitoring wells placed at intervals on the drain centerline indicate that groundwater is draining from the surrounding Maryville Formation (Conasauga Group); flows at catch basin No. 2 ranged from a base flow of 4 to 7 L/min to a maximum of 35 L/min, recorded on October 13. In response to groundwater flow in the drain, water levels in several monitoring wells adjacent to the drain have dropped by as much as 2.24 m to an elevation only slightly higher than the bottom of the French drain. In addition to the general lowering of the water table in the vicinity of the drain, water levels in three trenches began to subside, indicating that the drain is beginning to have an effect on the water in the trenches as well. Further monitoring of both drain discharge and water levels in monitoring wells across the site is continuing

  12. Signal attenuation due to cavity leakage

    International Nuclear Information System (INIS)

    Sherman, M.H.; Modera, M.P.

    1988-01-01

    The propagation of sound waves in fluids requires information about three properties of the system: capacitance (compressibility), resistance (friction), and inductance (inertia). Acoustical design techniques to date have tended to ignore the frictional effects associated with airflow across the envelope of the acoustic cavity (e.g., resistive vents). Since such leakage through the cavity envelope is best expressed with a power law dependence on the pressure, standard Fourier techniques that rely on linearity cannot be used. In this article, the theory relevant to nonlinear leakage is developed and equations presented. Potential applications of the theory to techniques for quantifying the leakage of buildings are presented. Experimental results from pressure decays in a full-scale test structure are presented and the leakage so measured is compared with independent measurements to demonstrate the technique

  13. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  14. Electroplating eliminates gas leakage in brazed areas

    Science.gov (United States)

    Leigh, J. D.

    1966-01-01

    Electroplating method seals brazed or welded joints against gas leakage under high pressure. Any conventional electroplating process with many different metal anodes can be used, as well as the build up of layers of different metals to any required thickness.

  15. A prospective randomized study of use of drain versus no drain after burr-hole evacuation of chronic subdural hematoma.

    Science.gov (United States)

    Singh, Amit Kumar; Suryanarayanan, Bhaskar; Choudhary, Ajay; Prasad, Akhila; Singh, Sachin; Gupta, Laxmi Narayan

    2014-01-01

    Chronic subdural hematoma (CSDH) recurs after surgical evacuation in 5-30% of patients. Inserting subdural drain might reduce the recurrence rate, but is not commonly practiced. There are few prospective studies to evaluate the effect of subdural drains. A prospective randomized study to investigate the effect of subdural drains in the on recurrence rates and clinical outcome following burr-hole drainage (BHD) of CSDH was undertaken. During the study period, 246 patients with CSDH were assessed for eligibility. Among 200 patients fulfilling the eligibility criteria, 100 each were assigned to "drain group" (drain inserted into the subdural space following BHD) and "without drain group" (subdural drain was not inserted following BHD) using random allocation software. The primary end point was recurrence needing re-drainage up to a period of 6 months from surgery. Recurrence occurred in 9 of 100 patients with a drain, and 26 of 100 patients in without drain group (P = 0.002). The mortality was 5% in patients with drain and 4% in patients without drain group (P = 0.744). The medical and surgical complications were comparable between the two study groups. Use of a subdural drain after burr-hole evacuation of a CSDH reduces the recurrence rate and is not associated with increased complications.

  16. Radioactivity leakage accidents in the feed water heater and the general drainage of the Tsuruga Nuclear Power Station of Japan Atomic Power Company

    International Nuclear Information System (INIS)

    1981-01-01

    In the Tsuruga Nuclear Power Station, JAPC on the shell on extracted-steam side in B system of No. 4 feed water heater, drain water leakage occurred twice in January, 1981. Then, 61 pCi/g cobalt-60 and 10 pCi/g manganese-54 were detected in soil at the outlet of general drainage on April 17, 1981. The cause was found to be the overflow of radioactive liquid waste in the filter sludge storage tank on March 8, the same year. On-the-spot inspection was subsequently made by the Agency of Natural Resources and Energy on both leakage accidents. The results of inspections are described as follows: the course of leakage accident, and also the measures taken to JAPC in connection with the two leakage accidents. (J.P.N.)

  17. Technology evaluation for space station atmospheric leakage

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  18. Carbon leakage from a Nordic perspective

    Energy Technology Data Exchange (ETDEWEB)

    Naess-Schmidt, S.; Hansen, Martin Bo; Sand Kirk, J. [Copenhagen Economics, Copenhagen (Denmark)

    2012-02-15

    Carbon pricing is generally considered a highly effective tool in reducing carbon emissions. Putting a price on carbon provides incentives for users and producers of fossil fuels to reduce consumption and develop low carbon products and processes. However, pursuing an ambitious climate policy can lead to carbon leakage, which refers to a situation where unilateral or regional climate change policy drives the relocation of industry investments and installations, and associated emissions, to third countries. This report by Copenhagen Economics has been commissioned by the Nordic Council of Ministers to give an overview of the industries at risk of carbon leakage in the Nordic countries, and estimate the expected extent of carbon leakage from unilateral climate policies in the Nordic countries. The report also assesses available policy options that may reduce the risk of carbon leakage, such as exemptions from energy tax and exemptions from quota obligations under green certificate schemes. The key drivers of carbon leakage are identified, which include energy intensity, product differentiation, transportation costs and capital intensity. The analysis suggests that industries such as paper and pulp, iron and steel, aluminium, cement, pharmaceuticals, chemicals, and fertilizers are most at risk of carbon leakage in the Nordic manufacturing sector. (Author)

  19. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J; Bosco, G; Darenbourg, B; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of

  20. Enhanced performance of amorphous In-Ga-Zn-O thin-film transistors using different metals for source/drain electrodes

    Science.gov (United States)

    Pyo, Ju-Young; Cho, Won-Ju

    2017-09-01

    In this paper, we propose an amorphous indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) with off-planed source/drain electrodes. We applied different metals for the source/drain electrodes with Ni and Ti to control the work function as high and low. When we measured the configuration of Ni to drain and source to Ti, the a-IGZO TFT showed increased driving current, decreased leakage current, a high on/off current ratio, low subthreshold swing, and high mobility. In addition, we conducted a reliability test with a gate bias stress test at various temperatures. The results of the reliability test showed the Ni drain and Ti drain had an equivalent effective energy barrier height. Thus, we confirmed that the proposed off-planed structure improved the electrical characteristics of the fabricated devices without any degradation of characteristics. Through the a-IGZO TFT with different source/drain electrode metal engineering, we realized high-performance TFTs for next-generation display devices.

  1. SLD-MOSCNT: A new MOSCNT with step-linear doping profile in the source and drain regions

    Science.gov (United States)

    Tahne, Behrooz Abdi; Naderi, Ali

    2017-01-01

    In this paper, a new structure, step-linear doping MOSCNT (SLD-MOSCNT), is proposed to improve the performance of basic MOSCNTs. The basic structure suffers from band to band tunneling (BTBT). We show that using SLD profile for source and drain regions increases the horizontal distance between valence and conduction bands at gate to source/drain junction which reduces BTBT probability. SLD performance is compared with other similar structures which have recently been proposed to reduce BTBT such as MOSCNT with lightly-doped drain and source (LDDS), and with double-light doping in source and drain regions (DLD). The obtained results using a nonequilibrium Green’s function (NEGF) method show that the SLD-MOSCNT has the lowest leakage current, power consumption and delay time, and the highest current ratio and voltage gain. The ambipolar conduction in the proposed structure is very low and can be neglected. In addition, these structures can improve short-channel effects. Also, the investigation of cutoff frequency of the different structures shows that the SLD has the highest cutoff frequency. Device performance has been investigated for gate length from 8 to 20 nm which demonstrates all discussions regarding the superiority of the proposed structure are also valid for different channel lengths. This improvement is more significant especially for channel length less than 12 nm. Therefore, the SLD can be considered as a candidate to be used in the applications with high speed and low power consumption.

  2. Source-Drain Punch-Through Analysis of High Voltage Off-State AlGaN/GaN HEMT Breakdown

    Science.gov (United States)

    Jiang, H.; Li, X.; Wang, J.; Zhu, L.; Wang, H.; Liu, J.; Wang, M.; Yu, M.; Wu, W.; Zhou, Y.; Dai, G.

    2017-06-01

    AlGaN/GaN high-electron mobility transistor’s (HEMT’s) off-state breakdown is investigated using conventional three-terminal off-state breakdown I-V measurement. Competition between gate leakage and source-injection buffer leakage (SIBL) is discussed in detail. It is found that the breakdown is dominated by source-injection which is sensitive to gate voltage and gate length at large gate-to-drain spacing (Lgd > 7μm), where a threshold drain voltage of the occurrence of the SIBL current in GaN buffer exists, and after this threshold voltage the SIBL current continually increased till the buffer breakdown. Our analysis showed that due to the punch-through effect in the buffer, a potential barrier between 2DEG and GaN buffer at the source side mainly controlled by the drain voltage determines the buffer leakage current and the occurrence of the following buffer breakdown, which could explain the experimentally observed breakdown phenomenon.

  3. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  4. The Treatment Of The RSU In Controlled Drains: Their Sanitary Problem To The Production Of Energy

    International Nuclear Information System (INIS)

    Calderon U, Rafael A.

    1995-01-01

    The limitless world production of residuals generates constant concerns with relationship to its administration. The classic elimination methods as the drains controlled in front of the controversial incineration plants and gasification as well as the expectations created around the recycle practices, are reason of intense debates among city councils, specialist, environmentalist technicians and the public in general. The certain thing is that the residuals in the last 30 years have been valued economically. Today in day the residuals are appreciated by certain sectors that begin to monopolize the line of the recycle because they come them an excellent business. All the methods of elimination of residuals produce in turn others. Those of solid nature in general go to the drain, the semi-liquids becomes dehydrated for the same end. Presently work, without seeking to say that the employment of the drains is the best option, thinks about how it has more than enough they are possible to optimize its use. Showing beside their eminently sanitary vocation an energy alternative that allows the use of the combustible gas that is generated in them. An added value that is interesting if this it becomes source of well-being for social excluded nuclei and economically like it happens for example in the peripheries of the drains of the big Latin American cities. They are considered which are the main aspects that intervene in the generation, production and quality of the gas methane of the drains. Their reception methods and their use alternatives. Lastly emphasis is made in the environmental situation to European and international level about the gases of the drain, how it thinks about the topic of the greenhouse effect and which are the actions for the horizon of the year 2000. They are related some experiences in Europe on the use of the biogas

  5. How to attribute market leakage to CDM projects

    NARCIS (Netherlands)

    Vöhringer, F.; Kuosmanen, T.K.; Dellink, R.B.

    2006-01-01

    Economic studies suggest that market leakage rates of greenhouse gas abatement can reach the two-digit percentage range. Although the Marrakesh Accords require Clean Development Mechanism (CDM) projects to account for leakage, most projects neglect market leakage. Insufficient leakage accounting is

  6. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  7. A study on the measurement of effective energy of leakage X-rays

    International Nuclear Information System (INIS)

    Fijimoto, Nobuhisa; Oogama, Noboru; Nishitani, Motohiro; Yamada, Katsuhiko

    1997-01-01

    It is important to correct for the energy response of the X-ray detector in measuring X-ray leakage from the protective barrier of the examination room. However, measurement of effective energy of leakage X-rays is very difficult in the clinical setting. In this paper, we discuss a method for estimating the effective energy of both primary and scattered X-rays. This method is based on the measurement of leakage X-ray spectra using a semiconductor-fitted X-ray detector and analyzing the relationship between X-ray tube voltage and effective energy. In this study. we found that the effective energy of leakage X-rays was not dependent on the thickness of shielding materials like concrete and lead. With the concrete barrier, it was possible to express the relation-ship between X-ray tube voltage and the effective energy of leakage X-rays with a simple approximate equation. With the lead-lined barrier, the absorption of the K-edge of lead needs to be considered in estimating the effective energy of leakage X-rays at relatively high tube voltages. (author)

  8. Cryogenic Fuel Tank Draining Analysis Model

    Science.gov (United States)

    Greer, Donald

    1999-01-01

    One of the technological challenges in designing advanced hypersonic aircraft and the next generation of spacecraft is developing reusable flight-weight cryogenic fuel tanks. As an aid in the design and analysis of these cryogenic tanks, a computational fluid dynamics (CFD) model has been developed specifically for the analysis of flow in a cryogenic fuel tank. This model employs the full set of Navier-Stokes equations, except that viscous dissipation is neglected in the energy equation. An explicit finite difference technique in two-dimensional generalized coordinates, approximated to second-order accuracy in both space and time is used. The stiffness resulting from the low Mach number is resolved by using artificial compressibility. The model simulates the transient, two-dimensional draining of a fuel tank cross section. To calculate the slosh wave dynamics the interface between the ullage gas and liquid fuel is modeled as a free surface. Then, experimental data for free convection inside a horizontal cylinder are compared with model results. Finally, cryogenic tank draining calculations are performed with three different wall heat fluxes to demonstrate the effect of wall heat flux on the internal tank flow field.

  9. Roundtable. Strategies to discourage brain drain.

    Science.gov (United States)

    Kupfer, Linda; Hofman, Karen; Jarawan, Raya; McDermott, Jeanne; Bridbord, Ken

    2004-08-01

    Building health research expertise in developing countries often requires personnel to receive training beyond national borders. For research funding agencies that sponsor this type of training, a major goal is to ensure that trainees return to their country of origin: attaining this objective requires the use of proactive strategies. The strategies described were developed under the extramural acquired immunodeficiency syndrome (AIDS) International Training and Research Program (AITRP) funded by the Fogarty International Center (FIC) at the National Institutes of Health, United States. This programme supports universities in the United States that provide research training to scientists from developing countries to enable them to address the global epidemic of human immunodeficiency virus (HIV)/AIDS and the related tuberculosis (TB) epidemic. This paper describes the strategies employed to discourage brain drain by the principle investigators (PIs) of five of the longest-funded AITRPs (funded for 15 years). Long-term trainees in these programmes spent from 11 to 96 months (an average of 26 months) studying. Using scientific, political and economic strategies that address brain drain issues, PIs working in AITRPs have attained an average rate of return home for their trainees of 80%.

  10. Is early detection of anastomotic leakage possible by intraperitoneal microdialysis and intraperitoneal cytokines after anterior resection of the rectum for cancer?

    Science.gov (United States)

    Matthiessen, Peter; Strand, Ida; Jansson, Kjell; Törnquist, Cathrine; Andersson, Magnus; Rutegård, Jörgen; Norgren, Lars

    2007-11-01

    This prospective study assessed methods of detecting intraperitoneal ischemia and inflammatory response in patients with and without postoperative complications after anterior resection of the rectum. In 23 patients operated on with anterior resection of the rectum for rectal carcinoma, intraperitoneal lactate, pyruvate, and glucose levels were monitored postoperatively for six days by using microdialysis with catheters applied in two locations: intraperitoneally near the anastomosis, and in the central abdominal cavity. A reference catheter was placed subcutaneously in the pectoral region. Cytokines, interleukin (IL)-6, IL-10, and tumor necrosis factor (TNF)-alpha, were measured in intraperitoneal fluid by means of a pelvic drain for two postoperative days. The intraperitoneal lactate/pyruvate ratio near the anastomosis was higher on postoperative Day 5 (P = 0.029) and Day 6 (P = 0.009) in patients with clinical anastomotic leakage (n = 7) compared with patients without leakage (n = 16). The intraperitoneal levels of IL-6 (P = 0.002; P = 0.012, respectively) and IL-10 (P = 0.002; P = 0.041, respectively) were higher on postoperative Days 1 and 2 in the leakage group, and TNF-alpha was higher in the leakage group on Day 1 (P = 0.011). In-hospital clinical anastomotic leakage was diagnosed on median Day 6, and leakage after hospital discharge on median Day 20. The intraperitoneal lactate/pyruvate ratio and cytokines, IL-6, IL-10, and TNF-alpha, were increased in patients who developed symptomatic anastomotic leakage before clinical symptoms were evident.

  11. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  12. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  13. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  14. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  15. Description of leakage monitoring system at Angra 2 nuclear power plant primary circuit

    International Nuclear Information System (INIS)

    Costa, Lilian Rose Sobral da; Mendes, Jorge Eduardo de Souza

    1999-01-01

    This paper describes the Leakage Monitoring System installed in Angra 2 NPP. This system has the task of detecting, localizing and quantifying leaks in systems for which rupture preclusion is cited. These systems include the reactor coolant pressure boundary, the main steam and feedwater lines within the containment, and the main steam safety and relief valve station in the valve annex. (author)

  16. Investigation of surface related leakage current in AlGaN/GaN High Electron Mobility Transistors

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, J.K., E-mail: janeshkaushik@sspl.drdo.in [Solid State Physics Laboratory, Delhi 110054 (India); Balakrishnan, V.R.; Mongia, D.; Kumar, U.; Dayal, S. [Solid State Physics Laboratory, Delhi 110054 (India); Panwar, B.S. [Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016 (India); Muralidharan, R. [Indian Institute of Science, Bengaluru, Karnataka 560012 (India)

    2016-08-01

    This paper reports the study of surface-related mechanisms to explain the high reverse leakage current observed in the in-house fabricated Si{sub 3}N{sub 4} passivated AlGaN/GaN High Electron Mobility Transistors. We propose that the Si{sub 3}N{sub 4}/AlGaN interface in the un-gated regions provides an additional leakage path between the gate and source/drain and may constitute a large component of reverse current. This surface related leakage component of current exhibits both temperature and electric field dependence and its Arrhenius behavior has been experimentally verified using Conductance Deep Level Transient Spectroscopy and temperature dependent reverse leakage current measurements. A thin interfacial amorphous semiconductor layer formed due to inter diffusion at Si{sub 3}N{sub 4}/AlGaN interface has been presumed as the source for this surface related leakage. We, therefore, conclude that optimum Si{sub 3}N{sub 4} deposition conditions and careful surface preparation prior to passivation can limit the extent of surface leakage and can thus vastly improve the device performance. - Highlights: • Enhanced leakage in AlGaN/GaN High Electron Mobility Transistors after passivation • Experimental evidence of the presence of extrinsic traps at Si{sub 3}N{sub 4}/AlGaN interface • Electron hopping in shallower extended defects and band tail traps at the interface. • Reduction in current collapse due to the virtual gate inhibition by this conduction • However, limitation on the operating voltages due to decrease in breakdown voltage.

  17. Carbon nanotube feedback-gate field-effect transistor: suppressing current leakage and increasing on/off ratio.

    Science.gov (United States)

    Qiu, Chenguang; Zhang, Zhiyong; Zhong, Donglai; Si, Jia; Yang, Yingjun; Peng, Lian-Mao

    2015-01-27

    Field-effect transistors (FETs) based on moderate or large diameter carbon nanotubes (CNTs) usually suffer from ambipolar behavior, large off-state current and small current on/off ratio, which are highly undesirable for digital electronics. To overcome these problems, a feedback-gate (FBG) FET structure is designed and tested. This FBG FET differs from normal top-gate FET by an extra feedback-gate, which is connected directly to the drain electrode of the FET. It is demonstrated that a FBG FET based on a semiconducting CNT with a diameter of 1.5 nm may exhibit low off-state current of about 1 × 10(-13) A, high current on/off ratio of larger than 1 × 10(8), negligible drain-induced off-state leakage current, and good subthreshold swing of 75 mV/DEC even at large source-drain bias and room temperature. The FBG structure is promising for CNT FETs to meet the standard for low-static-power logic electronics applications, and could also be utilized for building FETs using other small band gap semiconductors to suppress leakage current.

  18. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  19. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... on computational assumptions, our results are purely information-theoretic. In particular, we do not make use of public key encryption, which was required in all previous works...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied...

  20. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... and randomized processes with Markovian models and to compute their information leakage for a very general model of attacker. We present the QUAIL tool that automates such analysis and is able to compute the information leakage of an imperative WHILE language. Finally, we show how to use QUAIL to analyze some...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...

  1. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the 13 N content in the containment atmosphere. 13 N is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/ 13 N+ 4 He. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium 13 N concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  2. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/Nl3+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  3. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1979-08-01

    The present paper deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process H1+016 → N13+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m -3 and 7 kBq m -3 for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge (Li) flow detector assembly operated at elevated pressure. (Auth.)

  4. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attackers...... capable to observe the internal behavior of the system, and quantify the information leakage of such systems. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed and non-timed attacks...

  5. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice...... of information approach and is a natural framework for modeling refined attackers capable to observe the internal behavior of the system. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed...

  6. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  7. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  8. Fine root production at drained peatland sites

    Energy Technology Data Exchange (ETDEWEB)

    Finer, L [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Laine, J [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1997-12-31

    The preliminary results of the Finnish project `Carbon balance of peatlands and climate change` show that fine roots play an important role in carbon cycling on peat soils. After drainage the roots of mire species are gradually replaced by the roots of trees and other forest species. Pine fine root biomass reaches a maximum level by the time of crown closure, some 20 years after drainage on pine mire. The aim of this study is to compare the results of the sequential coring method and the ingrowth bag method used for estimating fine root production on three drained peatland sites of different fertility. The results are preliminary and continuation to the work done in the study Pine root production on drained peatlands, which is part of the Finnish project `Carbon cycling on peatlands and climate change`. In this study the fine root biomass was greater on the poor site than on the rich sites. Pine fine root production increased with the decrease in fertility. Root turnover and the production of field layer species were greater on the rich sites than on the poor site. The results suggested that the in growth bag method measured more root activity than the magnitude of production. More than two growing seasons would have been needed to balance the root dynamics in the in growth bags with the surrounding soil. That time would probably have been longer on the poor site than on the rich ones and longer for pine and field layer consisting of dwarf shrubs than for field layer consisting of sedge like species and birch. (11 refs.)

  9. Fine root production at drained peatland sites

    Energy Technology Data Exchange (ETDEWEB)

    Finer, L. [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Laine, J. [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1996-12-31

    The preliminary results of the Finnish project `Carbon balance of peatlands and climate change` show that fine roots play an important role in carbon cycling on peat soils. After drainage the roots of mire species are gradually replaced by the roots of trees and other forest species. Pine fine root biomass reaches a maximum level by the time of crown closure, some 20 years after drainage on pine mire. The aim of this study is to compare the results of the sequential coring method and the ingrowth bag method used for estimating fine root production on three drained peatland sites of different fertility. The results are preliminary and continuation to the work done in the study Pine root production on drained peatlands, which is part of the Finnish project `Carbon cycling on peatlands and climate change`. In this study the fine root biomass was greater on the poor site than on the rich sites. Pine fine root production increased with the decrease in fertility. Root turnover and the production of field layer species were greater on the rich sites than on the poor site. The results suggested that the in growth bag method measured more root activity than the magnitude of production. More than two growing seasons would have been needed to balance the root dynamics in the in growth bags with the surrounding soil. That time would probably have been longer on the poor site than on the rich ones and longer for pine and field layer consisting of dwarf shrubs than for field layer consisting of sedge like species and birch. (11 refs.)

  10. Leakage current suppression with a combination of planarized gate and overlap/off-set structure in metal-induced laterally crystallized polycrystalline-silicon thin-film transistors

    Science.gov (United States)

    Chae, Hee Jae; Seok, Ki Hwan; Lee, Sol Kyu; Joo, Seung Ki

    2018-04-01

    A novel inverted staggered metal-induced laterally crystallized (MILC) polycrystalline-silicon (poly-Si) thin-film transistors (TFTs) with a combination of a planarized gate and an overlap/off-set at the source-gate/drain-gate structure were fabricated and characterized. While the MILC process is advantageous for fabricating inverted staggered poly-Si TFTs, MILC TFTs reveal higher leakage current than TFTs crystallized by other processes due to their high trap density of Ni contamination. Due to this drawback, the planarized gate and overlap/off-set structure were applied to inverted staggered MILC TFTs. The proposed device shows drastic suppression of leakage current and pinning phenomenon by reducing the lateral electric field and the space-charge limited current from the gate to the drain.

  11. Vertical organic field effect phototransistor with two dissimilar source and drain contacts

    International Nuclear Information System (INIS)

    Woon, K.L.; Yeo, G.N.

    2014-01-01

    A solution processable vertical organic field effect phototransistor was fabricated using poly(3-hexylthiophene) and 1-(3-methoxycarbonyl)propyl-1-phenyl[6,6]C61 as the photo-active materials while poly(methyl methacrylate) is used as a dielectric layer. Interdigitated conductive poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) is used as a source and lithium flouride/aluminum as a drain. The device exhibits current modulation when the gate is positively biased. A significant photoeffect is observed in the reverse bias mode. Unlike conventional organic phototransistors, this device can operate at a zero source–drain bias with a photosensitivity and responsivity proportional to the gate voltage. A photosensitivity of up to 10 5 and a responsivity of up to 2 AW −1 are achieved in this mode. This effect is due to the presence of the weak photovoltaic behavior of this device. - Highlights: • A solution processable vertical field effect phototransistor is demonstrated. • Photosensitivity as high as ∼ 10 5 with responsivity of 2 AW −1 is achieved. • The gate can be used to modulate photocurrent with low leakage current. • The device shows weak photovoltaic behavior

  12. Origin of the water drained by the tunnel Graton; Origen de las aguas que drena el tunel Graton

    Energy Technology Data Exchange (ETDEWEB)

    Plata B, A [International Atomic Energy Agency, Vienna (Austria). Dept. of Research and Isotopes; Rojas M, R [Instituto Peruano de Energia Nuclear, Lima (Peru)

    1992-12-01

    The research of the origin of the water drained by the Graton tunnel was attempted using isotope techniques. During the period of studies (April 1989-October 1992), four field work was executed to sample waters for chemistry, stable isotope and Tritium analysis, an to inject tracers and verify the possible infiltration from the Rimac and Blanco rivers to the tunnel. The results of the stable isotope analysis show that the water drained by the Graton tunnel comes from a basin around 300 meters above the average altitude of the basin where the Graton is located. The Tritium analysis show that the water is relatively modern. Using the model of total mixing, the residence times of the water drained at the km 0.5 and 2.5 are in the order to 45 years. The conductivities of the water of the tunnel is higher than the Rimac river ones because the influence of mine water. The chemical analysis of the water sampled at the downstream end of the tunnel, show that the conservative ions of the water kept almost constant during more than two years. The results of the work with artificial tracer show that there is no significant leakage from the Rimac and Blanco rivers to the Graton tunnel. So far, it can be concluded as a preliminary approach that the Graton tunnel drains relatively modern water originated in another basin. The hydrodynamics of the area of study seems to include a large storage on underground water in the system. The topography, geology and isotopic composition of the water samples, points to the upper Mantaro river basin as the possible source of part of the water drained by the Graton tunnel. (authors). 20 p. 2 figs., 7 ills., 4 tabs.

  13. Brain drain from developing countries: how can brain drain be converted into wisdom gain?

    OpenAIRE

    Dodani, Sunita; LaPorte, Ronald E

    2005-01-01

    Brain drain is defined as the migration of health personnel in search of the better standard of living and quality of life, higher salaries, access to advanced technology and more stable political conditions in different places worldwide. This migration of health professionals for better opportunities, both within countries and across international borders, is of growing concern worldwide because of its impact on health systems in developing countries. Why do talented people leave their count...

  14. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  15. Poloidal field leakage optimization in ETE

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Carlos Shinya; Montes, Antonio

    1996-12-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs.

  16. The concept of leakage in threat assessment.

    Science.gov (United States)

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Secret rate - Privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.; Willems, F.M.J.

    2009-01-01

    Ahlswede and Csiszár [1993] introduced the concept of secret sharing. In their source model two terminals observe two correlated sequences. It is the objective of the terminals to form a common secret by interchanging a public message (helper data) in such a way that the secrecy leakage is

  18. Radiation leakage in nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Ando, Yoshio; Miyasaka, Shun-ichi; Takeuchi, Kiyoshi.

    1975-01-01

    Associated with the radiation leakage in MUTSU occurred in September 1974, this report reviews the shielding design for MUTSU, radiation measurement and inspection activities by a survey group, and 2 dimensional analysis on the behavior of fast neutrons to shielding based on Ssub(N) codes. In the first part, the purpose and the structure of the primary and the secondary shields of MUTSU are briefly illustrated. In the second part, the progress of the series of affairs is explained, starting from zero power criticality experiment, through discovery of radiation leakage in output-increasing test, sending of a survey group for various measurement and inspection, and finally to the conclusion drawn by the survey group. In the third part, various numerical analyses performed to investigate into the leakage are illustrated with their results. The transport codes used were ANISN, TWOTRAN, SPAN, and PALLAS-2DCY. As a result of those inspection and calculation, it was found that the radiation leakage was due to fast neutrons coming through the gap between the reactor vessel and the primary shield. (Aoki, K.)

  19. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  20. Poloidal field leakage optimization in ETE

    International Nuclear Information System (INIS)

    Shibata, Carlos Shinya; Montes, Antonio.

    1996-01-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs

  1. Zero leakage quantization scheme for biometric verification

    NARCIS (Netherlands)

    Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Biometrics gain increasing interest as a solution for many security issues, but privacy risks exist in case we do not protect the stored templates well. This paper presents a new verification scheme, which protects the secrets of the enrolled users. We will show that zero leakage is achieved if

  2. Generation of airborne Listeria innocua from model floor drains.

    Science.gov (United States)

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  3. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  4. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  5. Lung protein leakage in feline septic shock.

    Science.gov (United States)

    Schützer, K M; Larsson, A; Risberg, B; Falk, A

    1993-06-01

    The aim of the present study was to explore lung microvascular leakage of protein and water in a feline model of septic shock, using a double isotope technique with external gamma camera detection and gravimetric lung water measurements. The experiments were performed on artificially ventilated cats. One group of cats (n = 8) was given an infusion of live Escherichia coli bacteria, and another group (n = 5) served as a control group receiving saline. Plasma transferrin was radiolabeled in vivo with indium-113m-chloride, and erythrocytes were labeled with technetium-99m. The distribution of these isotopes in the lungs was continuously measured with a gamma camera. A normalized slope index (NSI) was calculated, indicative of the transferrin accumulation corrected for changes in local blood volume that reflect protein leakage. In the septic group there was a protein leakage after bacterial infusion, with a NSI of 39 x 10(-4) +/- 5 x 10(-4) min-1 (mean +/- SEM), and the PaO2 diminished from 21 +/- 1 to 9.5 +/- 1 kPa. In control cats a slight protein leakage with a NSI of 9 +/- 10(-4) +/- 2 x 10(-4) min-1 was detected, probably caused by the operative procedure, but PaO2 did not change. Wet-to-dry-weight ratios of postmortem lungs were not significantly different between the groups. It was concluded that an intravenous infusion of live E. coli bacteria induces a lung capillary protein leakage without increased lung water and a concomitantly disturbed gas exchange.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Management of cerebrospinal fluid leakage after anterior decompression for ossification of posterior longitudinal ligament in the thoracic spine: the utilization of a volume-controlled pseudomeningocele.

    Science.gov (United States)

    Cho, Ji Young; Chan, Chee Keong; Lee, Sang-Ho; Choi, Won-Chul; Maeng, Dae Hyeon; Lee, Ho-Yeon

    2012-06-01

    Retrospective review To determine the efficacy of management of cerebrospinal fluid (CSF) leakage after the anterior thoracic approach. CSF leakage after incidental durotomy commonly occurs after anterior thoracic ossification of posterior longitudinal ligament (OPLL) surgery. Pseudomeningocele will invariably form under such circumstances. Among them, uncontrolled CSF leakage with a fistulous condition is problematic. As a solution, we have managed these durotomies with chest drains alone without any CSF drainage by the concept of a "volume-controlled pseudomeningocele." Between 2001 and 2009, CSF leakage occurred in 26 patients (37.7%) of the total 69 patients who underwent anterior decompression for thoracic OPLL. In the initial 11 cases, subarachnoid drainage was utilized as an augmentive measure in combination with chest tube drainage in the postoperative period (group A). In the subsequent 15 cases, the durotomy was managed in a similar manner but in the absence of any subarachnoid drainage (group B). Various parameters such as the duration of postoperative hospital stay, clinical outcome score, drainage output, resolution of CSF leakage, complications, and additional surgery performed were analyzed and compared between the 2 groups. A resolution of the CSF leakage grading system was also proposed for the residual pseudomeningocele that formed in each group. There were statistically no significant differences in the outcome parameters between the 2 groups and also in patients with grade I or grade II residual pseudomeningocele of the new grading system. Two complications occurred in group A. No reexploration for persistent CSF leakage was required in both groups. CSF leakage managed with controlled chest tube drainage can produce a comparable result with those with additional subarachnoid drainage when watertight dural repair is impossible. The concept of controlled pseudomeningocele may be a useful and practical technique for the treatment of CSF leakage

  7. Improvement in the performance of graphene nanoribbon p-i-n tunneling field effect transistors by applying lightly doped profile on drain region

    Science.gov (United States)

    Naderi, Ali

    2017-12-01

    In this paper, an efficient structure with lightly doped drain region is proposed for p-i-n graphene nanoribbon field effect transistors (LD-PIN-GNRFET). Self-consistent solution of Poisson and Schrödinger equation within Nonequilibrium Green’s function (NEGF) formalism has been employed to simulate the quantum transport of the devices. In proposed structure, source region is doped by constant doping density, channel is an intrinsic GNR, and drain region contains two parts with lightly and heavily doped doping distributions. The important challenge in tunneling devices is obtaining higher current ratio. Our simulations demonstrate that LD-PIN-GNRFET is a steep slope device which not only reduces the leakage current and current ratio but also enhances delay, power delay product, and cutoff frequency in comparison with conventional PIN GNRFETs with uniform distribution of impurity and with linear doping profile in drain region. Also, the device is able to operate in higher drain-source voltages due to the effectively reduced electric field at drain side. Briefly, the proposed structure can be considered as a more reliable device for low standby-power logic applications operating at higher voltages and upper cutoff frequencies.

  8. Horner's syndrome caused by an intercostal chest drain.

    OpenAIRE

    Campbell, P; Neil, T; Wake, P N

    1989-01-01

    Horner's syndrome occurred in a young woman as a complication of the treatment of a traumatic pneumothorax with an intercostal drain. The nerve damage probably occurred when the lung had fully re-expanded, pressing the tip of the intercostal drain, lying at the apex of the pleural cavity, on to the sympathetic chain.

  9. Rethinking "Brain Drain" in the Era of Globalisation

    Science.gov (United States)

    Rizvi, Fazal

    2005-01-01

    This paper discusses a range of issues concerning the idea of "brain drain" within the context of recent thinking on transnational mobility. It argues that the traditional analyses of brain drain are not sufficient, and that we can usefully approach the topic from a postcolonial perspective concerned with issues of identity, national…

  10. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  11. The health workforce crisis: the brain drain scourge.

    Science.gov (United States)

    Ike, Samuel O

    2007-01-01

    The magnitude of the health workforce crisis engendered by brain drain particularly in Africa, and nay more especially Nigeria, has been assuming increasingly alarming proportions in the past three decades. The challenge it poses in meeting the manpower needs in the healthcare sector as well as in the larger economy of the sending countries is enormous. This paper thus sets out to highlight the scope of this brain drain, its effects and the reasons sustaining it, as well as makes concrete suggestions to help stern the tide. A review of the literature on brain drain with particular emphasis on the health workforce sector was done, with focus on Africa, and specifically Nigeria. Literature search was done using mainly the Medline, as well as local journals. The historical perspectives, with the scope of external and internal brain drain are explored. The glaring effects of brain drain both in the global workforce terrain and specifically in the health sectors are portrayed. The countries affected most and the reasons for brain drain are outlined. Strategic steps to redress the brain drain crisis are proffered in this paper. The health workforce crisis resulting from brain drain must be brought to the front-burner of strategic policy decisions leading to paradigm shift in political, social and economic conditions that would serve as incentives to curb the scourge.

  12. Influence of process parameters on threshold voltage and leakage current in 18nm NMOS device

    Science.gov (United States)

    Atan, Norani Binti; Ahmad, Ibrahim Bin; Majlis, Burhanuddin Bin Yeop; Fauzi, Izzati Binti Ahmad

    2015-04-01

    The process parameters are very crucial factor in the development of transistors. There are many process parameters that influenced in the development of the transistors. In this research, we investigate the effects of the process parameters variation on response characteristics such as threshold voltage (VTH) and sub-threshold leakage current (IOFF) in 18nm NMOS device. The technique to identify semiconductor process parameters whose variability would impact most on the device characteristic is realized through the process by using Taguchi robust design method. This paper presents the process parameters that influenced in threshold voltage (VTH) and sub-threshold leakage current (IOFF) which includes the Halo Implantation, Compensation Implantation, Adjustment Threshold voltage Implantation and Source/Drain Implantation. The design, fabrication and characterization of 18nm HfO2/TiSi2 NMOS device is simulated and performed via a tool called Virtual Wafer Fabrication (VWF) Silvaco TCAD Tool known as ATHENA and ATLAS simulators. These two simulators were combined with Taguchi L9 Orthogonal method to aid in the design and the optimization of the process parameters to achieve the optimum average of threshold voltage (VTH) and sub-threshold leakage current, (IOFF) in 18nm device. Results from this research were obtained; where Halo Implantation dose was identified as one of the process parameter that has the strongest effect on the response characteristics. Whereby the Compensation Implantation dose was identified as an adjustment factor to get the nominal values of threshold voltage VTH, and sub-threshold leakage current, IOFF for 18nm NMOS devices equal to 0.302849 volts and 1.9123×10-16 A/μm respectively. The design values are referred to ITRS 2011 prediction.

  13. The optimal design of 15 nm gate-length junctionless SOI FinFETs for reducing leakage current

    International Nuclear Information System (INIS)

    Liu, Xi; Wu, Meile; Jin, Xiaoshi; Chuai, Rongyan; Lee, Jung-Hee; Lee, Jong-Ho

    2013-01-01

    Junctionless (JL) transistors need to be heavily doped to have large drain current in the ON-state, which engenders the effect of band-to-band tunneling (BTBT) in the OFF-state simultaneously. It causes an obvious increase of the leakage current in the OFF-state. This paper presents an effective method of reducing the leakage current by changing the geometrical shape and dimension of the oxide layer under the edge of the gate. The optimal design of 15 nm gate-length JL silicon-on-insulator FinFETs with the triple-gate structure is performed for reducing the effect of BTBT through simulation and analysis by this means. (paper)

  14. Highly Reliable Transformerless Photovoltaic Inverters With Leakage Current and Pulsating Power Elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Loh, Poh Chiang

    2016-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common-mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Furthermore, the proposed inverter can also eliminate the well-known double-line-frequency pulsating...... power that is inherent in single-phase PV systems. By properly injecting CM voltages to the output filter capacitors, the pulsating power can be decoupled from the dc-link. Therefore, it is possible to use long-lifetime film capacitors instead of electrolytic capacitors to improve the reliability...

  15. Constraining Polarized Foregrounds for EoR Experiments. II. Polarization Leakage Simulations in the Avoidance Scheme

    Energy Technology Data Exchange (ETDEWEB)

    Nunhokee, C. D.; Bernardi, G.; Foster, G.; Grobler, T. L. [Department of Physics and Electronics, Rhodes University, P.O. Box 94, Grahamstown, 6140 (South Africa); Kohn, S. A.; Aguirre, J. E.; Martinot, J. Z. E. [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA (United States); Thyagarajan, N. [Arizona State University, School of Earth and Space Exploration, Tempe, AZ 85287 (United States); Dillon, J. S. [Berkeley Center for Cosmological Physics, Berkeley, CA 94720 (United States); Parsons, A. R., E-mail: cnunhokee@gmail.com [Dept. of Astronomy, University of California, Berkeley, CA 94720 (United States)

    2017-10-10

    A critical challenge in the observation of the redshifted 21 cm line is its separation from bright Galactic and extragalactic foregrounds. In particular, the instrumental leakage of polarized foregrounds, which undergo significant Faraday rotation as they propagate through the interstellar medium, may harmfully contaminate the 21 cm power spectrum. We develop a formalism to describe the leakage due to instrumental widefield effects in visibility-based power spectra measured with redundant arrays, extending the delay-spectrum approach presented in Parsons et al. We construct polarized sky models and propagate them through the instrument model to simulate realistic full-sky observations with the Precision Array to Probe the Epoch of Reionization. We find that the leakage due to a population of polarized point sources is expected to be higher than diffuse Galactic polarization at any k mode for a 30 m reference baseline. For the same reference baseline, a foreground-free window at k > 0.3 h Mpc{sup −1} can be defined in terms of leakage from diffuse Galactic polarization even under the most pessimistic assumptions. If measurements of polarized foreground power spectra or a model of polarized foregrounds are given, our method is able to predict the polarization leakage in actual 21 cm observations, potentially enabling its statistical subtraction from the measured 21 cm power spectrum.

  16. Pancreatic anastomosis leakage management following pancreaticoduodenectomy how could be manage the anastomosis leakage after pancreaticoduodenectomy?

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Tabatabei

    2015-01-01

    Full Text Available Background: Pancreatic anastomosis leakage and fistula formation following pancreaticoduodenectomy (Whipple′s procedure is a common complication. Delay in timely diagnosis and proper management is associated with high morbidity and mortality. To report our experience with management of pancreatic fistula following Whipple′s procedure. Materials and Methods: In this retrospective study, medical records of 90 patients who underwent Whipple′s procedure from 2009 to 2013 at our medical center were reviewed for documents about pancreatic anastomosis leakage and fistula formation. Results: There were 15 patients who developed pancreatico-jejunal anastomosis leakage. In 6 patients (3 males and 3 females the leakage was mild (conservative therapy was administered, but in 9 patients (6 males and 3 females, there was severe leakage. For the latter group, surgical intervention was done (2 cases underwent re-anastomosis and for 7 cases pancreatico-jejunal stump ligation was done along with drainage of the location. Conclusion: In severe pancreatic anastomotic leakage, it is better to intervene surgically as soon as possible by debridement of the distal part of the pancreas and ligation of the stump with nonabsorbable suture. Furthermore, debridement of the jejunum should be done, and the stump should be ligated thoroughly along with drainage.

  17. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  18. Incidence and management of pancreatic leakage after pancreatoduodenectomy

    NARCIS (Netherlands)

    de Castro, S. M. M.; Busch, O. R. C.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    2005-01-01

    Background: Optimal management of severe pancreatic leakage after pancreatoduodenectomy can reduce morbidity and mortality. Completion pancreatectomy may be adequate but leads to endocrine insufficiency. This study evaluated an alternative management strategy for pancreatic leakage. Methods: Outcome

  19. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  20. Effects of annealing gas and drain doping concentration on electrical properties of Ge-source/Si-channel heterojunction tunneling FETs

    Science.gov (United States)

    Bae, Tae-Eon; Wakabayashi, Yuki; Nakane, Ryosho; Takenaka, Mitsuru; Takagi, Shinichi

    2018-04-01

    Improvement in the performance of Ge-source/Si-channel heterojunction tunneling FETs (TFETs) with high on-current/off-current (I on/I off) ratio and steep subthreshold swing (SS) is demonstrated. In this paper, we experimentally examine the effects of gas ambient [N2 and forming gas (4% H2/N2)] and a doping concentration in the drain regions on the electrical characteristics of Ge/Si heterojunction TFETs. The minimum SS (SSmin) of 70.9 mV/dec and the large I on/I off ratio of 1.4 × 107 are realized by postmetallization annealing in forming gas. Also, the steep SSmin and averaged SS (SSavr) values of 64.2 and 78.4 mV/dec, respectively, are obtained in low drain doping concentration. This improvement is attributable to the reduction in interface state density (D it) in the channel region and to the low leakage current in the drain region.

  1. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  2. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  3. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  4. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  5. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  6. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  7. Decommissioning of fast reactors after sodium draining

    International Nuclear Information System (INIS)

    2009-11-01

    Acknowledging the importance of passing on knowledge and experience, as well mentoring the next generation of scientists and engineers, and in response to expressed needs by Member States, the IAEA has undertaken concrete steps towards the implementation of a fast reactor data retrieval and knowledge preservation initiative. Decommissioning of fast reactors and other sodium bearing facilities is a domain in which considerable experience has been accumulated. Within the framework and drawing on the wide expertise of the Technical Working Group on Fast Reactors (TWG-FR), the IAEA has initiated activities aiming at preserving the feedback (lessons learned) from this experience and condensing those to technical recommendations on fast reactor design features that would ease their decommissioning. Following a recommendation by the TWG-FR, the IAEA had convened a topical Technical Meeting (TM) on 'Operational and Decommissioning Experience with Fast Reactors', hosted by CEA, Centre d'Etudes de Cadarache, France, from 11 to 15 March 2002 (IAEA-TECDOC- 1405). The participants in that TM exchanged detailed technical information on fast reactor operation and decommissioning experience with various sodium cooled fast reactors, and, in particular, reviewed the status of the various decommissioning programmes. The TM concluded that the decommissioning of fast reactors to reach safe enclosure presented no major difficulties, and that this had been accomplished mainly through judicious adaptation of processes and procedures implemented during the reactor operation phase, and the development of safe sodium waste treatment processes. However, the TM also concluded that, on the path to achieving total dismantling, challenges remain with regard to the decommissioning of components after sodium draining, and suggested that a follow-on TM be convened, that would provide a forum for in-depth scientific and technical exchange on this topic. This publication constitutes the Proceedings of

  8. A tangent subsolar merging line

    International Nuclear Information System (INIS)

    Crooker, N.U.; Siscoe, G.L.; Toffoletto, F.R.

    1990-01-01

    The authors describe a global magnetospheric model with a single subsolar merging line whose position is determined neither locally by the relative orientations and strengths of the merging fields nor globally by the orientation of a separator line--the governing parameters of most previous models--but by the condition of tangential contact between the external field and the magnetopause. As in previous models, the tilt of the merging line varies with IMF orientation, but here it also depends upon the ratio of Earth's magnetic flux that leaks out of the magnetopause to IMF flux that penetrates in. In the limiting case treated by Alekseyev and Belen'kaya, with no leakage of Earth's field and total IMF penetration, the merging line forms a great circle around a spherical magnetosphere where undeviated IMF lines lie tangent to its surface. This tangent merging line lies perpendicular to the IMF. They extend their work to the case of finite leakage and partial penetration, which distort the IMF into a draped pattern, thus changing the locus of tangency to the sphere. In the special case where the penetrating IMF flux is balanced by an equal amount of Earth flux leakage, the tangent merging line bisects the angle between the IMF and Earth's northward subsolar field. This result is identical to the local merging line model result for merging fields with equal magnitude. Here a global flux balance condition replaces the local equal magnitude condition

  9. Serial measurement of radiation leakage dose rates in safekeeping at the Gammaknife room

    International Nuclear Information System (INIS)

    Baba, Sadaaki; Nozaki, Kenichi; Toyoda, Tatsuya; Wakamatsu, Osamu; Machida, Toru

    2006-01-01

    We report the serial measurement of leakage dose rates in safekeeping at the Gammaknife room during the past 4 years and 9 months by scintillation survey meter. The leakage dose rates at the radiation boundaries were the same as the natural background levels. Leakage dose rates at each shield calculation point from two 90 Sr calibration sources contained in the storehouse were negligible compared with those from 60 Co sources of the Gammaknife. 60 Co sources of the Gammaknife are arranged in 201 pieces at 10 degree interval on the circumference and in five lines within an arc of 35 degrees. Its shield container is made of iron at least 43 cm thick. We got leakage dose rates less than 40% of the calculated values. We think it is caused by the difference of each actual distance and shield thickness because 60 Co sources are usually considered as a point source in the shield calculation. There are shutters opening up and down when patients go in and out to the direction of the couch. The leakage values to this direction were about twice as much as the calculated value. So, we knew the thickness of those shutters was thinner than 43 cm. The half life time of 60 Co source calculated from the serial measurements of leakage dose rates was 4.93 years on average. It is 94% of the physical half life value of 5.27 years. We judged it was acceptable considering the difficulty of measuring low dose rate level with the radiation survey meter. Very strong correlation was observed between the decrease of 60 Co dose rate acquired from one minute measurement at the center of 18 cm diameter polysterene phantom gotten from December 2000 to August 2005 and that of computation based on the physical half life time. Likewise there was strong and more correlation with leakage dose rate in the Gammaknife room. From this, we deduce the leakage dose rate decreases according to the theory of the disintegration of radioactivity with passage of time. Revised radiation related laws took effect

  10. Variants of hepatobiliary leakage: Biloma and aberrant drainage paths - case report

    Energy Technology Data Exchange (ETDEWEB)

    Mack, J M; Peracha, H; Sziklas, J J; Rosenberg, R J; Spencer, R P

    1987-04-01

    Three variants of abnormal biliary drainage, on Tc-99m-DIPIDA studies, were illustrated, despite patency of the normal pathway. A 23-year-old man had gun shot fragments removed from the liver. An area originally negative for uptake of the hepatobiliary agent later demonstrated an increased content after the remainder of the liver had drained (a biloma). A 67-year-old woman showed passage of Tc-99m-DIPIDA simultaneously from 2 pathways. One was via a biliary-cutaneous fistula site along a prior T-tube tract, and the other was into the small intestine via a biliary stent. Following cholecystectomy, a hepatobiliary study in a 46-year-old man revealed a 'gallbladder'. This represented leakage into the prior gallbladder bed. The hepatobiliary agents can exit via traumatically or surgically created pathways, even when the 'usual' anatomic drainage is present.

  11. Definition and grading of anastomotic leakage following anterior resection of the rectum: a proposal by the International Study Group of Rectal Cancer.

    Science.gov (United States)

    Rahbari, Nuh N; Weitz, Jürgen; Hohenberger, Werner; Heald, Richard J; Moran, Brendan; Ulrich, Alexis; Holm, Torbjörn; Wong, W Douglas; Tiret, Emmanuel; Moriya, Yoshihiro; Laurberg, Søren; den Dulk, Marcel; van de Velde, Cornelis; Büchler, Markus W

    2010-03-01

    Anastomotic leakage represents a major complication after anterior resection of the rectum. The incidence of anastomotic leakage varies considerably among clinical studies in part owing to the lack of a standardized definition of this complication. The aim of the present article was to propose a definition and severity grading of anastomotic leakage after anterior rectal resection. After a literature review a consensus definition and severity grading of anastomotic leakage was developed within the International Study Group of Rectal Cancer. Anastomotic leakage should be defined as a defect of the intestinal wall at the anastomotic site (including suture and staple lines of neorectal reservoirs) leading to a communication between the intra- and extraluminal compartments. Severity of anastomotic leakage should be graded according to the impact on clinical management. Grade A anastomotic leakage results in no change in patients' management, whereas grade B leakage requires active therapeutic intervention but is manageable without re-laparotomy. Grade C anastomotic leakage requires re-laparotomy. The proposed definition and clinical grading is applicable easily in the setting of clinical studies. It should be applied in future reports to facilitate valid comparison of the results of different studies. Copyright 2010 Mosby, Inc. All rights reserved.

  12. Advances in chest drain management in thoracic disease

    Science.gov (United States)

    George, Robert S.

    2016-01-01

    An adequate chest drainage system aims to drain fluid and air and restore the negative pleural pressure facilitating lung expansion. In thoracic surgery the post-operative use of the conventional underwater seal chest drainage system fulfills these requirements, however they allow great variability amongst practices. In addition they do not offer accurate data and they are often inconvenient to both patients and hospital staff. This article aims to simplify the myths surrounding the management of chest drains following chest surgery, review current experience and explore the advantages of modern digital chest drain systems and address their disease-specific use. PMID:26941971

  13. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  14. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  15. Predicting artificailly drained areas by means of selective model ensemble

    DEFF Research Database (Denmark)

    Møller, Anders Bjørn; Beucher, Amélie; Iversen, Bo Vangsø

    . The approaches employed include decision trees, discriminant analysis, regression models, neural networks and support vector machines amongst others. Several models are trained with each method, using variously the original soil covariates and principal components of the covariates. With a large ensemble...... out since the mid-19th century, and it has been estimated that half of the cultivated area is artificially drained (Olesen, 2009). A number of machine learning approaches can be used to predict artificially drained areas in geographic space. However, instead of choosing the most accurate model....... The study aims firstly to train a large number of models to predict the extent of artificially drained areas using various machine learning approaches. Secondly, the study will develop a method for selecting the models, which give a good prediction of artificially drained areas, when used in conjunction...

  16. Development of Charge Drain Coatings: Final CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Elam, Jeffrey W. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-17

    The primary goal of this CRADA project was to develop and optimize tunable resistive coatings prepared by atomic layer deposition (ALD) for use as charge-drain coatings on the KLA-Tencor digital pattern generators (DPGs).

  17. The stable stiffness triangle - drained sand during deformation cycles

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    2017-01-01

    Cyclic, drained sand stiffness was observed using the Danish triaxial appa- ratus. New, deformation dependant soil property (the stable stiffness triangle) was detected. Using the the stable stiffness triangle, secant stiffness of drained sand was plausible to predict (and control) even during ir...... findings can find application in off-shore, seismic and other engi- neering practice, or inspire new branches of research and modelling wherever dynamic, cyclic or transient loaded sand is encountered....

  18. Drain Back Systems in Laboratory and in Practice

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2015-01-01

    in the collector loop to have a safe reliable operation. The components should also be designed and marked so that only one correct mounting option is possible, like forward and return pipes to/from the collector of slightly different sizes or color. Adapted installer education and training is a very important...... step to have success with drain back systems. Practices used in glycol systems may give serious failures. Key-words: Drain Back, Low Flow, Solar Combi System, ETC collectors....

  19. Cold Vacuum Drying facility effluent drain system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) effluent drain system (EFS). The primary function of the EFS is to collect and transport fire suppression water discharged into a CVDF process bay to a retention basin located outside the facility. The EFS also provides confinement of spills that occur inside a process bay and allows non-contaminated water that drains to the process bay sumps to be collected until sampling and analysis are complete

  20. Steam generator fitted with a dynamic draining device

    International Nuclear Information System (INIS)

    Chaix, J.E.

    1982-01-01

    This generator has, at its upper part, at least one drying structure for holding the water carried with the steam and communicating at its lower part with at least one discharge pipe for draining off the water, each pipe communicating with a dynamic draining device capable of creating a depression in order to suck up the water contained in the drying structure. Application is for pressurized water nuclear reactors [fr

  1. Prevention of Information Leakage by Photo-Coupling in Smart Card

    Science.gov (United States)

    Shen, Sung-Shiou; Chiu, Jung-Hui

    Advances in smart card technology encourages smart card use in more sensitive applications, such as storing important information and securing application. Smart cards are however vulnerable to side channel attacks. Power consumption and electromagnetic radiation of the smart card can leak information about the secret data protected by the smart card. Our paper describes two possible hardware countermeasures that protect against side channel information leakage. We show that power analysis can be prevented by adopting photo-coupling techniques. This method involves the use of LED with photovoltaic cells and photo-couplers on the power, reset, I/O and clock lines of the smart card. This method reduces the risk of internal data bus leakage on the external data lines. Moreover, we also discuss the effectiveness of reducing electromagnetic radiation by using embedded metal plates.

  2. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    Science.gov (United States)

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  3. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran [Univ. of Gaevle, Gaevle (Sweden); Meijer, Jan-Erik; Rosqvist, Haakan [NSR AB, Helsingborg (Sweden)

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  4. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  5. Leakage warning system for flexible underwater pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, E; Bernstein, L

    1985-08-01

    Underwater pipelines for unloading oil tankers, e.g. in 30 km distance from the harbour site, are required to be flexible and require supervision. This is done by implementation of oil sensitive sensors between the inner rubber tube and the following impregnated textile layer. The generated sensor signals, influenced by leak oil, have to be wireless transmitted from 150 meters under water to the supervisory station at the coast. Sensor configurations are described, to derive the point of the leakage from the topologized warning signals.

  6. Facepiece leakage and fitting of respirators

    International Nuclear Information System (INIS)

    White, J.M.

    1978-05-01

    The ways in which airborne contaminants can penetrate respirators and the factors which affect the fit of respirators are discussed. The fit of the respirator to the face is shown to be the most critical factor affecting the protection achieved by the user. Qualitative and quantitative fit testing techniques are described and their application to industrial respirator programs is examined. Quantitative measurement of the leakage of a respirator while worn can be used to numerically indicate the protection achieved. These numbers, often referred to as protection factors, are sometimes used as the basis for selecting suitable respirators and this practice is reviewed. (author)

  7. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  8. Unusual dialysate leakage complicating peritoneal dialysis

    International Nuclear Information System (INIS)

    Chiu, Jainn-Shiun; Yu, Fu-Chiu; Chen, Chiou-An; Wang, Yuh-Feng

    2006-01-01

    A 16-year-old female who had end-stage renal disease on 2-month continuous ambulatory peritoneal dialysis (CAPD) presented with perineal pain 4 days before admission. The physical examination revealed bilateral labial edema. Peritoneal scintigraphy was requested after infusing 2 L peritoneal dialysate with direct administration of 370 MBq (10mCi) technetium-99m diethylenetriamine pentra-acetic acid into peritoneal cavity via Tenckhoff catheter. Radioactive uptake from right inguinal to labial region was clearly demonstrated, and this indicated the site of peritoneal leakage. After surgical intervention unilaterally, she continued CAPD without any recurrence (au)

  9. Leakage and field emission in side-gate graphene field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Di Bartolomeo, A., E-mail: dibant@sa.infn.it; Iemmo, L.; Romeo, F.; Cucolo, A. M. [Physics Department “E.R. Caianiello,” University of Salerno, via G. Paolo II, 84084 Fisciano (Italy); CNR-SPIN Salerno, via G. Paolo II, 84084 Fisciano (Italy); Giubileo, F. [CNR-SPIN Salerno, via G. Paolo II, 84084 Fisciano (Italy); Russo, S.; Unal, S. [Physics Department, University of Exeter, Stocker Road 6, Exeter, Devon EX4 4QL (United Kingdom); Passacantando, M.; Grossi, V. [Department of Physical and Chemical Sciences, University of L' Aquila, Via Vetoio, 67100 Coppito, L' Aquila (Italy)

    2016-07-11

    We fabricate planar graphene field-effect transistors with self-aligned side-gate at 100 nm from the 500 nm wide graphene conductive channel, using a single lithographic step. We demonstrate side-gating below 1 V with conductance modulation of 35% and transconductance up to 0.5 mS/mm at 10 mV drain bias. We measure the planar leakage along the SiO{sub 2}/vacuum gate dielectric over a wide voltage range, reporting rapidly growing current above 15 V. We unveil the microscopic mechanisms driving the leakage, as Frenkel-Poole transport through SiO{sub 2} up to the activation of Fowler-Nordheim tunneling in vacuum, which becomes dominant at higher voltages. We report a field-emission current density as high as 1 μA/μm between graphene flakes. These findings are important for the miniaturization of atomically thin devices.

  10. Brain drain from developing countries: how can brain drain be converted into wisdom gain?

    Science.gov (United States)

    Dodani, Sunita; LaPorte, Ronald E

    2005-01-01

    Brain drain is defined as the migration of health personnel in search of the better standard of living and quality of life, higher salaries, access to advanced technology and more stable political conditions in different places worldwide. This migration of health professionals for better opportunities, both within countries and across international borders, is of growing concern worldwide because of its impact on health systems in developing countries. Why do talented people leave their countries and go abroad? What are the consequences of such migrations especially on the educational sector? What policies can be adopted to stem such movements from developing countries to developed countries? This article seeks to raise questions, identify key issues and provide solutions which would enable immigrant health professionals to share their knowledge, skills and innovative capacities and thereby enhancing the economic development of their countries. PMID:16260795

  11. Role of wound instillation with bupivacaine through surgical drains for postoperative analgesia in modified radical mastectomy

    Directory of Open Access Journals (Sweden)

    Nirmala Jonnavithula

    2015-01-01

    Full Text Available Background and Aims: Modified Radical Mastectomy (MRM is the commonly used surgical procedure for operable breast cancer, which involves extensive tissue dissection. Therefore, wound instillation with local anaesthetic may provide better postoperative analgesia than infiltration along the line of incision. We hypothesised that instillation of bupivacaine through chest and axillary drains into the wound may provide postoperative analgesia. Methods: In this prospective randomised controlled study 60 patients aged 45-60 years were divided into three groups. All patients were administered general anaesthesia. At the end of the surgical procedure, axillary and chest wall drains were placed before closure. Group C was the control with no instillation; Group S received 40 ml normal saline, 20 ml through each drain; and Group B received 40 ml of 0.25% bupivacaine and the drains were clamped for 10 min. After extubation, pain score for both static and dynamic pain was evaluated using visual analog scale and then 4 th hourly till 24 h. Rescue analgesia was injection tramadol, if the pain score exceeds 4. Statistical analysis was performed using SPSS version 13. Results : There was a significant difference in the cumulative analgesic requirement and the number of analgesic demands between the groups (P: 0.000. The mean duration of analgesia in the bupivacaine group was 14.6 h, 10.3 in the saline group and 4.3 h in the control group. Conclusion : Wound instillation with local anaesthetics is a simple and effective means of providing good analgesia without any major side-effects.

  12. Study of the patency of different peritoneal drains used prophylactically in bariatric surgery.

    Science.gov (United States)

    Salgado Júnior, Wilson; Macedo Neto, Marcelo Martins; dos Santos, José Sebastião; Sakarankutty, Ajith Kumar; Ceneviva, Reginaldo; de Castro e Silva, Orlando

    2009-05-21

    To compare the performance of different types of abdominal drains used in bariatric surgery. A vertical banded Roux-en-Y gastric bypass was performed in 33 morbidly obese patients. Drainage of the peritoneal cavity was performed in each case using three different types of drain selected in a randomized manner: a latex tubular drain, a Watterman tubulolaminar drain, and a silicone channeled drain. Drain permeability, contamination of the drained fluid, ease of handling, and patient discomfort were evaluated postoperatively over a period of 7 d. The patients with the silicone channeled drain had larger volumes of drainage compared to patients with tubular and tubulolaminar drains between the third and seventh postoperative days. In addition, a lower incidence of discomfort and of contamination with bacteria of a more pathogenic profile was observed in the patients with the silicone channeled drain. The silicone channeled drain was more comfortable and had less chance of occlusion, which is important in the detection of delayed dehiscence.

  13. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  14. Leakage in the Juelich research reactor

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    On August 17, 1978, a leakage occurred in the DIDO research reactor. Early in the afternoon of this day, the valves of the coolant loop had been checked with the reactor shut off. When the mechanics wanted to oil a tight valve and drilled a hole in the valve cover for this, heavy water started to leak (leakage in the valve membrane). The mechanics left the shielded valve space at once; directly after having a shower, they underwent a radiation protection examination. It was found that none of the mechanics had been exposed to an excessive dose. When other mechanics in protective suits had closed the leak in the valve, a total of 150 liters had leaked into the sump pump at the valve entrance. They were pumped back into the cooling system. About 5 liters of water were evaporated and, via the stack, escaped into the environment. The activity released was about 40 curie; this is less than the permissible amount of 60 curie per week during normal operation. Neither the KFA personnel nor the inhabitants of Juelich and its surroundings were in danger at any moment. Calculations so far yield a maximum radiation exposure below 1mrem at the point of maximum exposure. The cooling circuit could be entered again only one day after the incident. The present shut-off phase of the reactor is not unduly prolonged by this accident. (orig./HP) [de

  15. Nurses’ Knowledge Levels of Chest Drain Management: A Descriptive Study

    Directory of Open Access Journals (Sweden)

    Merve Tarhan

    2016-12-01

    Full Text Available Objective: The physician is responsible for inserting one or more chest tubes into the pleural space or the mediastinal space and connecting them to an appropriate drainage system. When the general principles about care of patients with chest drains were implemented correctly and effectively by nurses, nurse will contribute to accelerate the healing process of patients. In this context, the aim of this study was to determine the nurses’ level of knowledge regarding the care of patients with chest drains. Methods: The study was conducted with 153 nurses who worked in a chest diseases and thoracic surgery hospital in July 2014. Questionnaire form of 35 questions prepared by investigators was used to collect data. For the analysis of results, frequency tests, independent sample t-test and oneway ANOVA test were used. Results: 69.3% of nurses stated that they had obtained information from colleguages. 35.3% considered their knowledge about chest drain management to be inadequate. 55.6% scored 13 points and above from knowledge questionnaire about chest drain management. There were statistically significant difference between knowledge level and educational background, clinic work type, working unit, years of professional experience and institutional experience, frequency of contact patients with chest drain and perception of knowledge level (p<0.05. Conclusion: Results of this study indicate that lack of evidence-based nursing care and insufficient training has resulted in uncertainty and knowledge deficit in important aspects of chest drain care. It can be concluded that nurses receive training needs and training protocols are about chest drain management.

  16. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  17. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  18. Device for preventing leakage of coolant in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kobayashi, Yukio; Sekiguchi, Mamoru; Yoshida, Hideo.

    1975-01-01

    Object: To prevent leakage of coolant from between lower tie plate and channel box without causing deformation of the channel box and also without the possibility of disturbing the installation and removal of the box by the provision of a thin plate provided with leakage holes for the lower tie plate. Structure: Static water pressure within the lower tie plate is adapted to act upon the bear side of a flat plate for leakage prevention through leakage holes formed in the tie plate, thus urging the flat plate against the channel box inner surface. Meanwhile, static water pressure having been led through the leakage holes in the flat plate is adapted to press the flat plate in the vertical direction, thus urging the flat plate against the channel box inner surface and thereby preventing leakage of the coolant through a gap between the channel box and lower tie plate. (Yoshino, Y.)

  19. AIRFIX: the first digital postoperative chest tube airflowmetry--a novel method to quantify air leakage after lung resection.

    Science.gov (United States)

    Anegg, Udo; Lindenmann, Jorg; Matzi, Veronika; Mujkic, Dzenana; Maier, Alfred; Fritz, Lukas; Smolle-Jüttner, Freyja Maria

    2006-06-01

    Prolonged air leak after pulmonary resection is a common complication and a major limiting factor for early discharge from hospital. Currently there is little consensus on its management. The aim of this study was to develop and evaluate a measuring device which allows a simple digital bed-side quantification of air-leaks compatible to standard thoracic drainage systems. The measuring device (AIRFIX) is based upon a 'mass airflow' sensor with a specially designed software package that is connected to a thoracic suction drainage system. Its efficacy in detecting pulmonary air-leaks was evaluated in a series of 204 patients; all postoperative measurements were done under standardized conditions; the patients were asked to cough, to take a deep breath, to breathe out against the resistance of a flutter valve, to keep breath and to breathe normally. As standard parameters, the leakage per breath or cough (ml/b) as well as the leakage per minute (ml/min) were displayed and recorded on the computer. Air-leaks within a range of 0.25-45 ml/b and 5-900 ml/min were found. Removal of the chest tubes was done when leakage volume on Heimlich valve was less than 1.0 ml/b or 20 ml/min. After drain removal based upon the data from chest tube airflowmetry none of the patients needed re-drainage due to pneumothorax. The AIRFIX device for bed-side quantification of air-leaks has proved to be very simple and helpful in diagnosis and management of air-leaks after lung surgery, permitting drain removal without tentative clamping.

  20. Rainwater drained through fully filled pipes

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, B; Koestel, P

    1989-02-01

    The conventional rainwater drainage system according to DIN 1986 always seems to be a point of problemacy in the building services as far as the occupancy of installation shafts and ducts is at stake. The excavation work and the necessary gravity lines are considered to be expensive. The consideration of the necessary slope complicates the installation additionally. Basing on those considerations, the raindraining system with fully filled pipes has been developed. DIN 1986, edition June 1988, part 1, point 6.1.1 allows to install rainwater pipes operated as planned, fully filled without slope. An enterprise specialised in building services investigated all system laws because only by a hydraulically exact balance, the function of the rainwater drainage system operated by negative and positive pressure can be insured. The results of those investigations are integrated in a computer program developed for this purpose.

  1. Assessment of the use of selected chemical and microbiological constituents as indicators of wastewater in curtain drains from home sewage-treatment systems in Medina County, Ohio

    Science.gov (United States)

    Dumouchelle, Denise H.

    2006-01-01

    Many home sewage-treatment systems (HSTS) in Ohio use curtain or perimeter drains to depress the level of the subsurface water in and around the systems. These drains could possibly intercept partially untreated wastewater and release potential pathogens to ground-water and surface-water bodies. The quality of water in curtain drains from two different HSTS designs in Medina County, Ohio, was investigated using several methods. Six evaporation-transpiration-absorption (ETA) and five leach-line (LL) systems were investigated by determining nutrient concentrations, chloride/bromide ratios (Cl/Br), Escherichia coli (E. coli ) concentrations, coliphage genotyping, and genetic fingerprinting of E. coli. Water samples were collected at 11 sites and included samples from curtain drains, septic tanks, and residential water wells. Nitrate concentrations in the curtain drains ranged from 0.03 to 3.53 mg/L (milligrams per liter), as N. Concentrations of chloride in 10 of the 11 curtain drains ranged from 5.5 to 21 mg/L; the chloride concentration in the eleventh curtain drain was 340 mg/L. Bromide concentrations in 11 curtain drains ranged from 0.01 to 0.22 mg/L. Cl/Br ratios ranged from 86 to 2,000. F-specific coliphage were not found in any curtain-drain samples. Concentrations of E. coli in the curtain drains ranged from 1 to 760 colonies per 100 milliliters. The curtain-drain water-quality data were evaluated to determine whether HSTS-derived water was present in the curtain drains. Nutrient concentrations were too low to be of use in the determination. The Cl/Br ratios appear promising. Coliphage was not detected in the curtain drains, so genotyping could not be attempted. E. coli concentrations in the curtain drains were all less than those from the corresponding HSTS; only one sample exceeded the Ohio secondary-contact water-quality standard. The genetic fingerprinting data were inconclusive because multiple links between unrelated sites were found. Although the

  2. Leaching of dissolved phosphorus from tile-drained agricultural areas.

    Science.gov (United States)

    Andersen, H E; Windolf, J; Kronvang, B

    2016-01-01

    We investigated leaching of dissolved phosphorus (P) from 45 tile-drains representing animal husbandry farms in all regions of Denmark. Leaching of P via tile-drains exhibits a high degree of spatial heterogeneity with a low concentration in the majority of tile-drains and few tile-drains (15% in our investigation) having high to very high concentration of dissolved P. The share of dissolved organic P (DOP) was high (up to 96%). Leaching of DOP has hitherto been a somewhat overlooked P loss pathway in Danish soils and the mechanisms of mobilization and transport of DOP needs more investigation. We found a high correlation between Olsen-P and water extractable P. Water extractable P is regarded as an indicator of risk of loss of dissolved P. Our findings indicate that Olsen-P, which is measured routinely in Danish agricultural soils, may be a useful proxy for the P leaching potential of soils. However, we found no straight-forward correlation between leaching potential of the top soil layer (expressed as either degree of P saturation, Olsen-P or water extractable P) and the measured concentration of dissolved P in the tile-drain. This underlines that not only the source of P but also the P loss pathway must be taken into account when evaluating the risk of P loss.

  3. Radiologic assessment of spinal CSF leakage in spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Han, Chang Jin; Kim, Ji Hyung; Kim, Jang Sung; Kim, Sun Yong; Suh, Jung Ho

    1999-01-01

    To assess the usefulness of imaging modalities in the detection of spinal CSF leakage in spontaneous intracranial hypotension. Fifteen patients who complained of postural headache without any preceding cause showed typical brain MR findings of intracranial hypotension, including radiologically confirmed CSF leakage. All fifteen underwent brain MRI and radionuclide cisternography. CT myelography was performed in eight patients and spinal MRI in six. Medical records, imaging findings and the incidence of spinal CSF leakage during each modality were retrospectively reviewed. CSF leakage was most common at the cervicothoracic junction, where in seven of 15 cases it was seen on radionuclide cisternography as increased focal paraspinal activity. Leakage was noted at the mid-tho-racic level in three patients, at the upper thoracic level in two, and at the cervical and lumbar levels in the remaining two. In two patients multiple CSF leaks were noted, and in all, early radioactive accumulation in the bladder was visualized. CT myelography revealed extrathecal and paraspinal contrast leakage in three of eight patients, and among those who underwent spinal MRI, dural enhancement was observed at the site of CSF leakage in all six, abnormal CSF signal in the neural foramen in one, and epidural CSF collection in one. Radionuclide cisternography is a useful method for the detection of CSF leakage in spontaneous intracranial hypotension. CT myelography and spinal MRI help determine the precise location of leakage

  4. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  5. Current practice patterns of drain usage amongst UK and Irish surgeons performing bilateral breast reductions: Evidence down the drain.

    Science.gov (United States)

    Sugrue, Conor M; McInerney, Niall; Joyce, Cormac W; Jones, Deidre; Hussey, Alan J; Kelly, Jack L; Kerin, Michael J; Regan, Padraic J

    2015-01-01

    Bilateral breast reduction (BBR) is one of the most frequently performed female breast operations. Despite no evidence supporting efficacy of drain usage in BBRs, postoperative insertion is common. Recent high quality evidence demonstrating potential harm from drain use has subsequently challenged this traditional practice. The aim of this study is to assess the current practice patterns of drains usage by Plastic & Reconstructive and Breast Surgeons in UK and Ireland performing BBRs. An 18 question survey was created evaluating various aspects of BBR practice. UK and Irish Plastic & Reconstructive and Breast Surgeons were invited to participate by an email containing a link to a web-based survey. Statistical analysis was performed with student t-test and chi-square test. Two hundred and eleven responding surgeons were analysed, including 80.1% (171/211) Plastic Surgeons and 18.9% (40/211) Breast Surgeons. Of the responding surgeons, 71.6% (151/211) routinely inserted postoperative drains, for a mean of 1.32 days. Drains were used significantly less by surgeons performing ≥20 BBRs (p = 0.02). With the majority of BBRs performed as an inpatient procedure, there was a trend towards less drain usage in surgeons performing this procedure as an outpatient; however, this was not statistically significant (p = 0.07). Even with the high level of evidence demonstrating the safety of BBR without drains, they are still routinely utilised. In an era of evidence- based medicine, surgeons performing breast reductions must adopt the results from scientific research into their clinical practice.

  6. Rendezvous technique treatment for late-onset biliary leakage after major hepatectomy of a living donor: report of a case.

    Science.gov (United States)

    Kimura, Koichi; Ikegami, Toru; Yamashita, Yo-ichi; Saeki, Hiroshi; Oki, Eiji; Yoshizumi, Tomoharu; Uchiyama, Hideaki; Kawanaka, Hirofumi; Soejima, Yuji; Morita, Masaru; Shirabe, Ken; Ikeda, Tetsuo; Maehara, Yoshihiko

    2013-09-01

    Biliary leakage is a major complication after hepatectomy. We report the case of a living-donor liver transplantation (LDLT) donor with a late-onset bile leak from the trifurcation of the hepatic duct who was successfully treated using rendezvous technique. A 52-year-old man underwent extended left hepatectomy for donation and was discharged on postoperative day (PD) 13. However, he was rehospitalized on PD 26 with severe abdominal pain. Physical examination suggested panperitonitis, and abdominocentesis showed bilious ascites. Emergent laparotomy for biliary leakage and peritonitis was performed. There was bilious ascites in the peritoneal cavity. A biliary fistula was recognized at the trifurcation of B8a, B8b, and B5. Intraoperative transhepatic biliary drainage of each bile duct was performed. Endoscopic transpapillary drainage was performed on PD 24. Finally, external drains were removed and complete internal drainage established on PD 70. The bile leak was considered to be the result of injury from electrocautery device. Appropriate making choices of the electrocautery devices enable us to avoid over thermal injury of the liver surface. Rendezvous bidirectional drainage effectively treated late-onset bile leakage from the trifurcation of a hepatic bile duct.

  7. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  8. Fluid leakage near the percolation threshold

    Science.gov (United States)

    Dapp, Wolf B.; Müser, Martin H.

    2016-02-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again.

  9. Leakages and pressure relation: an experimental research

    Directory of Open Access Journals (Sweden)

    F. De Paola

    2012-11-01

    Full Text Available Leaks in water systems are presently a frequent and increasing event that involves cost increase and poor service, not compliant to quality standards and modern management criteria. The most recent data available in Italy, resumed into the report issued by Control Committee for Water Resources Use (CONVIRI, shows leakages with an average value of 37%. It is therefore important, for maintenance perspective, to investigate occurrence and evolution of water leaks and the analytical link between leaks Qp and network pressure P, for a reliable calibration of water networks quali-quantitative simulation models. The present work reports the first results of an experimental campaign started at Laboratory of Hydraulics of Department of Hydraulics, Geotechnical and Environmental Engineering of University of Naples Federico II in order to analyze the features of Qp(P relation, which are compared with other results issued in literature.

  10. Potential gonadal dose from leakage radiation?

    International Nuclear Information System (INIS)

    Nicholson, R.A.

    1995-01-01

    The author draws attention to the potential dangers of leakage radiation from mobile image intensifier units, and points out that during interventional urological procedures, radiation from below the urologist's knees may irradiate male gonads without being intercepted by protective aprons. Results are presented for a Shimatzu WHA mobile II, phantom doses being measured with an ionization chamber. Dose rates measured in the male gonad position were compared with rates at waist level behind a 0.35 mm lead equivalent shielding and dose rates at collar level outside the lead apron. Results are also presented of a study on the effect on gonad dose of a) adding 0.7 mm lead shielding to the tube housing and b) adding 0.7 mm lead and removing the spacer cone to reduce scatter. Results show that it is possible for gonad doses to be comparable with those assumed for the eyes, rather than the body. (Author)

  11. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  12. A study of the complications of small bore 'Seldinger' intercostal chest drains.

    Science.gov (United States)

    Davies, Helen E; Merchant, Shairoz; McGown, Anne

    2008-06-01

    Use of small bore chest drains (drainage over a 12-month period. One hundred consecutive small bore Seldinger (12F) chest drain insertions were evaluated. Few serious complications occurred. However, 21% of the chest drains were displaced ('fell out') and 9% of the drains became blocked. This contributed to high morbidity rates, with 13% of patients requiring repeat pleural procedures. The frequency of drain blockage in pleural effusion was reduced by administration of regular normal saline drain flushes (odds ratio for blockage in flushed drains compared with non-flushed drains 0.04, 95% CI: 0.01-0.37, P < 0.001). Regular chest drain flushes are advocated in order to reduce rates of drain blockage, and further studies are needed to determine optimal fixation strategies that may reduce associated patient morbidity.

  13. Frequency dependence and passive drains in fish-eye lenses

    Science.gov (United States)

    Quevedo-Teruel, O.; Mitchell-Thomas, R. C.; Hao, Y.

    2012-11-01

    The Maxwell fish eye lens has previously been reported as being capable of the much sought after phenomenon of subwavelength imaging. The inclusion of a drain in this system is considered crucial to the imaging ability, although its role is the topic of much debate. This paper provides a numerical investigation into a practical implementation of a drain in such systems, and analyzes the strong frequency dependence of both the Maxwell fish eye lens and an alternative, the Miñano lens. The imaging capability of these types of lens is questioned, and it is supported by simulations involving various configurations of drain arrays. Finally, a discussion of the near-field and evanescent wave contribution is given.

  14. The effect of drains on the alkalinity of agricultural soils

    International Nuclear Information System (INIS)

    Iqbal, M.A.; Butt, T.; Anwar-ul-Haque; Haroon, M.; Haq, I.U.

    2009-01-01

    The purpose of the study was to observe the effect of industrial and domestic drains on the nearby agricultural areas which are either irrigated or not by the waste water but are close to drains. For this purpose 48 soil samples were collected from the selected areas of Faisalabad and were analyzed for alkali metals like Na/sup +/, K/sup +/, Li/sup +/ and some alkaline earth metals like Ba/sup 2+/> Mg/sup 3+/> Na/sup +/> K/sup +/> Li/sup +/ the levels of Ba/sup +2/ and K/sup +/ were found higher than permissible levels in almost all the soil samples. It was also concluded that the agricultural areas near the industrial drain which are either irrigated or not by the industrial waste water are found highly contaminated with mobile alkali metals (K, Na etc.) and higher values of percentage salinity. (author)

  15. Optimization design for drain to nuclear power condenser

    International Nuclear Information System (INIS)

    Ding Jiapeng; Jiang Chengren

    2010-01-01

    Characters and varieties of drain to nuclear power condenser are discussed in this paper. Take the main steam system of a nuclear power as an example, normal and detailed optimization design are introduced, related expatiate are used as a reference for the drain of other systems. According to the characters of nuclear power instant operation, the influence and needed actions related with the optimization design are also analyzed. Based on the above research, the scheme has been carried out in a nuclear power station and safety for the condenser operation of the nuclear power has been improved largely. (authors)

  16. Rare bile duct anomaly: B3 duct draining to gallbladder

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2016-01-01

    Full Text Available A 10-year-old girl presented with recurrent right upper abdominal pain and dyspepsia. Magnetic resonance cholangiopancreatography revealed a dilated common channel of intrahepatic bile duct of segment 3 (B3 and segment 4 (B4 drained into the gallbladder directly. The patient underwent laparoscopic cholecystectomy and Roux-en Y hepaticojejunostomy (B3-jejunostomy. Among the anatomical variability of the biliary system, the cholecystohepatic ducts are controversial in existence and incidence. We report a very rare variant of a cholecystohepatic duct in which the B3 duct drained into gallbladder directly and to the best of our knowledge this is the first report.

  17. Study of drain-extended NMOS under electrostatic discharge stress in 28 nm and 40 nm CMOS process

    Science.gov (United States)

    Wang, Weihuai; Jin, Hao; Dong, Shurong; Zhong, Lei; Han, Yan

    2016-02-01

    Researches on the electrostatic discharge (ESD) performance of drain-extended NMOS (DeNMOS) under the state-of-the-art 28 nm and 40 nm bulk CMOS process are performed in this paper. Three distinguishing phases of avalanche breakdown stage, depletion region push-out stage and parasitic NPN turn on stage of the gate-grounded DeNMOS (GG-DeNMOS) fabricated under 28 nm CMOS process measured with transmission line pulsing (TLP) test are analyzed through TCAD simulations and tape-out silicon verification detailedly. Damage mechanisms and failure spots of GG-DeNMOS under both CMOS processes are thermal breakdown of drain junction. Improvements based on the basic structure adjustments can increase the GG-DeNMOS robustness from original 2.87 mA/μm to the highest 5.41 mA/μm. Under 40 nm process, parameter adjustments based on the basic structure have no significant benefits on the robustness improvements. By inserting P+ segments in the N+ implantation of drain or an entire P+ strip between the N+ implantation of drain and polysilicon gate to form the typical DeMOS-SCR (silicon-controlled rectifier) structure, the ESD robustness can be enhanced from 1.83 mA/μm to 8.79 mA/μm and 29.78 mA/μm, respectively.

  18. Study of novel junctionless Ge n-Tunneling Field-Effect Transistors with lightly doped drain (LDD) region

    Science.gov (United States)

    Liu, Xiangyu; Hu, Huiyong; Wang, Bin; Wang, Meng; Han, Genquan; Cui, Shimin; Zhang, Heming

    2017-02-01

    In this paper, a novel junctionless Ge n-Tunneling Field-Effect Transistors (TFET) structure is proposed. The simulation results show that Ion = 5.5 × 10-5A/μm is achieved. The junctionless device structure enhances Ion effectively and increases the region where significant BTBT occurs, comparing with the normal Ge-nTEFT. The impact of the lightly doped drain (LDD) region is investigated. A comparison of Ion and Ioff of the junctionless Ge n-TFET with different channel doping concentration ND and LDD doping concentration NLDD is studied. Ioff is reduced 1 order of magnitude with the optimized ND and NLDD are 1 × 1018cm-3 and 1 × 1017 cm-3, respectively. To reduce the gate induced drain leakage (GIDL) current, the impact of the sloped gate oxide structure is also studied. By employing the sloped gate oxide structure, the below 60 mV/decade subthreshold swing S = 46.2 mV/decade is achieved at Ion = 4.05 × 10-5A/μm and Ion/Ioff = 5.7 × 106.

  19. Strained Si channel NMOSFETs using a stress field with Si1-yC y source and drain stressors

    International Nuclear Information System (INIS)

    Chang, S.T.; Tasi, H.-S.; Kung, C.Y.

    2006-01-01

    The strain field in the silicon channel of a metal-oxide-semiconductor transistor with silicon-carbon alloy source and drain stressors was evaluated using the commercial process simulator FLOOPS-ISE TM . The physical origin of the strain components in the transistor channel region was explained. The magnitude and distribution of the strain components, and their dependence on device design parameters such as the spacing L G between the silicon-carbon alloy stressors, the carbon mole fraction in the stressors and stressor depth were investigated. Reducing the stressor spacing L G or increasing the carbon mole fraction in the stressors and stressor depth increases the magnitude of the vertical compressive stress and the lateral tensile stress in the portion of the N channel region where the inversion charge resides. This is beneficial for improving the electron mobility in n-channel metal-oxide-semiconductor transistors. A simple guiding principle for an optimum combination of the above-mentioned device design parameters in terms of mobility enhancement, drain current enhancement and the tradeoff consideration for junction leakage current degradation

  20. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    Science.gov (United States)

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

  1. An Equal-Strain Analytical Solution for the Radial Consolidation of Unsaturated Soils by Vertical Drains considering Drain Resistance

    Directory of Open Access Journals (Sweden)

    Feng Zhou

    2018-01-01

    Full Text Available Developing an analytical solution for the consolidation of unsaturated soils remains a challenging task due to the complexity of coupled governing equations for air and water phases. This paper presents an equal-strain model for the radial consolidation of unsaturated soils by vertical drains, and the effect of drain resistance is also considered. Simplified governing equations are established, and an analytical solution to calculate the excess pore-air and pore-water pressures is derived by using the methods of matrix analysis and eigenfunction expansion. The average degrees of consolidation for air and water phases and the ground surface settlement are also given. The solutions of the equal-strain model are verified by comparing the proposed free-strain model with the equal-strain model, and reasonably good agreement is obtained. Moreover, parametric studies regarding the drain resistance effect are graphically presented.

  2. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  3. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  4. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    A recent trend in cryptography is to formally prove the leakage resilience of cryptographic implementations – that is, one formally shows that a scheme remains provably secure even in the presence of side channel leakage. Although many of the proposed schemes are secure in a surprisingly strong m...

  5. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  6. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third, the ran...

  7. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  8. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  9. Hunting the unknown: White-box database leakage detection

    NARCIS (Netherlands)

    Costante, E.; Hartog, den J.I.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.; Atluri, V.; Pernul, G.

    2014-01-01

    Data leakage causes significant losses and privacy breaches worldwide. In this paper we present a white-box data leakage detection system to spot anomalies in database transactions. We argue that our approach represents a major leap forward w.r.t. previous work because: i) it significantly decreases

  10. Determination of Unidentified Leakage Using a Kalman Smoother

    International Nuclear Information System (INIS)

    Jang, Soek Bo; Heo, Gyunyoung; Ra, Insik; Han, Jeonghyun; Lee, Seon Woo

    2008-01-01

    Since the safety significance of leaks from the RCS can widely vary depending on the source of the leak as well as the leak rate, the detection of the leakage is an important issue. The leakage is classified into 1) identified leakage which is defined as leakage into closed systems such as pump seal or valve packing leaks that can be captured, and 2) unidentified leakage which is all other leakage. The unidentified leakage is typically determined by the RCS inventory balance method which is based on NUREG-1107. Since the accuracy of leak rate calculation is dependent of the plant operating condition, the change in the RCS temperature, inventory, and the transient operating condition should be avoided during the measurement period. Nevertheless, the operation of the makeup of the borated water into the RCS and the diversion of the inventory to the outside of the RCS boundary makes it difficult to maintain the plant stable over an hour. Due to the large fluctuation of the calculated leak rate, it is sometimes hard to know the trend of the leakage as well as the instantaneous leak rate. Any fluctuation of operating conditions can results in unreliable leak rate. This study proposes a new way of determining the unidentified leak rate using a Kalman filter and smoother technique. The proposed algorithm enhances the accuracy of the leak rate calculation not only for the steady state operations but also for transients in a well timed manner

  11. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  12. Managing the Cost of Plant Piping System Leakage

    International Nuclear Information System (INIS)

    Jenco, John M.; Keck, Donna R.; Johnson, Gary L.

    2002-01-01

    Recent studies have shown that the average annual cost impact of external piping system leakage on commercial nuclear plant operations and maintenance can easily range into the millions of dollars for each reactor unit. Evidence suggests that this significant O and M cost reduction opportunity has largely been overlooked, due to the number of diverse line items and budget areas affected. Results released last year from an EPRI pilot study of more than a dozen reactor units at seven plant sites operated by multiple utilities found that the average annual cost impact was indeed around $1.6 million per year per unit. Subsequent field experience has also demonstrated that an effective fluid leak management program can substantially reduce these costs within the first three years of implementation. This paper presents the general cost impact research results from various studies, outlines key elements of an effective plant fluid leak management program, discusses important implementation issues, and presents results from case studies covering different utility approaches to developing and implementing an effective fluid leak management program. Actual cost data will be included where appropriate. (authors)

  13. Failure analysis of leakage current in plastic encapsulated packages

    International Nuclear Information System (INIS)

    Hu, S.J.; Cheang, F.T.

    1989-12-01

    Plastic encapsulated packages exhibit high leakage current after a few hundred hours steam pressure pot test. The present study investigates two possible sources of leakage current, the mold compound and the lead frame tape used for taping the lead frame fingers. The results of the study indicate that the leakage current is independent of the frame and is not caused by the mold compound. The data further indicates that it is the ionic contents and acrylic-based adhesive layer of the lead frame tapes which cause the leakage current. To eliminate the leakage current, lead frame tape with low ionic contents and non acrylic-based adhesive should be used. (author). 1 fig., 2 tabs, 3 graphs

  14. An objective comparison of leakage between commonly used earplugs.

    Science.gov (United States)

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P leakage when compared with the cotton ball coated with petroleum jelly (P leakage compared with the customized plug (P leakage than the cotton plug (P leakage rate (f(4,45) = 94 [P water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. PERFORMANCE OF LEAKAGE POWER MINIMIZATION TECHNIQUE FOR CMOS VLSI TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    T. Tharaneeswaran

    2012-06-01

    Full Text Available Leakage power of CMOS VLSI Technology is a great concern. To reduce leakage power in CMOS circuits, a Leakage Power Minimiza-tion Technique (LPMT is implemented in this paper. Leakage cur-rents are monitored and compared. The Comparator kicks the charge pump to give body voltage (Vbody. Simulations of these circuits are done using TSMC 0.35µm technology with various operating temper-atures. Current steering Digital-to-Analog Converter (CSDAC is used as test core to validate the idea. The Test core (eg.8-bit CSDAC had power consumption of 347.63 mW. LPMT circuit alone consumes power of 6.3405 mW. This technique results in reduction of leakage power of 8-bit CSDAC by 5.51mW and increases the reliability of test core. Mentor Graphics ELDO and EZ-wave are used for simulations.

  16. Leakage current characteristics of the multiple metal alloy nanodot memory

    International Nuclear Information System (INIS)

    Lee, Gae Hun; Lee, Jung Min; Yang, Hyung Jun; Song, Yun Heub; Bea, Ji Chel; Tanaka, Tetsu

    2010-01-01

    The leakage current characteristics of a multiple metal alloy nanodot device for a nonvolatile random access memory using FePt materials are investigated. Several annealing conditions are evaluated and optimized to suppress the leakage current and to better the memory characterisctics. This work confirmed that the annealing condition of 700 .deg. C in a high vacuum ambience (under 1 x 10 -5 Pa) simultaneously provided good cell characteristics from a high dot density of over 1 x 10 13 /cm 2 and a low leakage current. In addition, a smaller nanodot diameter was found to give a lower leakage current for the multiple nanodot memory. Finally, for the proposed annealing condition, the quadruple FePt multiple nanodot memory with a 2-nm dot diameter provided good leakage current characteristics, showing a threshold voltage shift of under 5% at an initial retention stage of 1000 sec.

  17. Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

    Directory of Open Access Journals (Sweden)

    Bing Luo

    2012-07-01

    Full Text Available In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of the fractal dimension in the forecast zone are calculated to characterize the differences. The analysis reveals large differences in the fractal dimension of leakage current under different contamination discharge stages and degrees. The experimental and calculation results suggest that the fractal dimension of a leakage current waveform can be used as a new indicator of the discharge process and contamination degree of insulators. The results provide new methods and valid indicators for forecasting contamination flashovers.

  18. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  19. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    -secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol......In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... against continual memory leakage, under the Bilinear Decisional Diffie-Hellman and $2$-linear assumptions. Our schemes have the following properties: 1. Our DPKE and DIBE schemes tolerate leakage at all times, including during refresh. During refresh the tolerated leakage is a (1/2-o (1),1)-fraction...

  20. The management of vacuum neck drains in head and neck surgery and the comparison of two different practice protocols for drain removal.

    Science.gov (United States)

    Kasbekar, A V; Davies, F; Upile, N; Ho, M W; Roland, N J

    2016-01-01

    Introduction The management of vacuum neck drains in head and neck surgery is varied. We aimed to improve early drain removal and therefore patient discharge in a safe and effective manner. Methods The postoperative management of head and neck surgical patients with vacuum neck drains was reviewed retrospectively. A new policy was then implemented to measure drainage three times daily (midnight, 6am, midday). The decision for drain removal was based on the most recent drainage period (at Measuring drainage volumes three times daily allows for more accurate assessment of wound drainage, and this can lead to earlier removal of neck drains and safe discharge.

  1. Brain drain or brain gain : The case of Suriname

    NARCIS (Netherlands)

    T.W. Dulam (Tina)

    2015-01-01

    markdownabstractAbstract Brain drain refers to the emigration of highly skilled individuals mostly from a less developed (home) to a developed country (destination) thereby reducing the capacity of the home country to generate welfare for its population. In the literature there is much written

  2. Outcome in Chronic Subdural Hematoma After Subdural vs. Subgaleal Drain.

    Science.gov (United States)

    Ishfaq, Asim

    2017-07-01

    To compare the outcome after surgery for chronic subdural hematoma when the drain is placed in subdural space or subgaleal space. Quasi experimental study. Combined Military Hospital, Lahore, from July 2015 to June 2016. Patients with chronic subdural hematoma of both genders and age, ranging between 55 to 85 years, were included. Patients on antiplatelet/anticoagulant therapy and acute on chronic subdural hematoma were excluded. Patients were divided in two equal groups each depending on whether drain was placed in subgaleal space (Group 1), and subdual space (Group 2), (n=31 patients each). Patients were positioned flat in bed after surgery. Clinical and radiological parameters and clinical outcome were compared between the two groups. Statistical test with significance of p hematoma was 15 ±6.5 mm. Patients with subdural drain placement had more complications such as pneumocephalus 11 (35.4%) vs. 6 (19.3%), and intracerebral hemorrhage 4 (12.9%) vs. 2 (6.4%). Clinical outcome was good in both groups 27 (87%) in Group 1 and 28 (90%) in Group 2. Patients of both groups had good outcome after surgery. Complications like pneumocephalus and intracerebral hemorrhage were more common in subdural location of drain, though not reaching statistically significance level to favor one technique over another.

  3. On the use of drains in orthopedic and trauma

    African Journals Online (AJOL)

    2013-11-08

    Nov 8, 2013 ... Even major procedures like total knee and arthroplasties are being performed without drains. We set to find ... discourage wound healing while encouraging bacterial ... a period of two days or if drainage over the first twenty‑four hours was found ... Three of the twenty Kuntscher nailings for femoral fracture.

  4. Brain Drain: A Child's Brain on Poverty. Poverty Fact Sheet

    Science.gov (United States)

    Damron, Neil

    2015-01-01

    "Brain Drain: A Child's Brain on Poverty," released in March 2015 and prepared by intern Neil Damron, explores the brain's basic anatomy and recent research findings suggesting that poverty affects the brain development of infants and young children and the potential lifelong effects of the changes. The sheet draws from a variety of…

  5. Moving Policy Forward: "Brain Drain" as a Wicked Problem

    Science.gov (United States)

    Logue, Danielle

    2009-01-01

    The mobility of scientists and the concerns surrounding "brain drain" are not new. Even in the Ptolemic dynasty, the first king set out to attract and influence the movements of scholars to shift the centre of learning from Athens to Alexandria. Yet after all this time, there is still much policy discourse and debate focused on attempting to…

  6. An Improvised Active Drain | Ogirima | Nigerian Journal of Surgical ...

    African Journals Online (AJOL)

    An improvised active drain is designed from intravenous infusion set and recycled RedivacR or Haemovac® bottle. Outcome of the use of this system on 100 patients is presented. This suction drainage system had been used in major orthopaedic and common minor surgical procedures and no significant complication was ...

  7. Case Report: Supernumerary right renal vein draining inferior to the ...

    African Journals Online (AJOL)

    With recent increase in renal transplantations, renovascular reconstructions and imaging advances, meticulous knowledge of the normal and variant anatomy of the renal vasculature is important to avoid potential pitfalls. We report a case of an accessory renal vein arising from the right kidney, and draining into the inferior ...

  8. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    The Xpand chest drain is an external medical device made of plastic that incorporates a fluid reservoir, a one-way valve and an air-leak detection system ... conect ed to a 2 000 ml drainage bag) prevents exposure of body fluids to nursing staff.

  9. English and the Brain Drain : An Uncertain Relationship

    NARCIS (Netherlands)

    Houtkamp, C.

    2016-01-01

    In his book Linguistic Justice for Europe and the World, Van Parijs analyses in one of his chapters the brain drain from non-Anglophone to Anglophone countries, which hurts the economic development of the nonAnglophone states. Van Parijs deems it clear that English is a very important factor to

  10. Organic loss in drained wetland: managing the carbon footprint

    NARCIS (Netherlands)

    Durham, B.; van de Noort, R.; Martens, V.V.; Vorenhout, M.

    2012-01-01

    The recent installation of land drains at Star Carr, Yorkshire, UK, has been linked with loss of preservation quality in this important Mesolithic buried landscape, challenging the PARIS principle. Historically captured organic carbon, including organic artefacts, is being converted to soluble

  11. Brain Drain in Higher Education: Lost Hope or Opportunity?

    Science.gov (United States)

    Odhiambo, George

    2012-01-01

    The flight of human capital is a phenomenon that has been of concern to academics and development practitioners for decades but unfortunately, there is no systematic record of the number of skilled professionals that many African countries have continued to lose to the developed world. Termed the "brain drain", it represents the loss of…

  12. Phosphorus modeling in tile drained agricultural systems using APEX

    Science.gov (United States)

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  13. Drains after Thyroidectomy for Benign Thyroid Disorders; Are ...

    African Journals Online (AJOL)

    Prophylactic drainage after thyroidectomy has been a regular practice at Kenyatta National Hospital( KNH). This has been ... stay and post-operative pain. Introduction. Prophylactic drains are still regularly used in ..... Total versus subtotal thyroidectomy for the management of benign multinodular goiter in an endemic region.

  14. Influence of Hudiara Drain Water Irrigation on Trace Elements Load ...

    African Journals Online (AJOL)

    ... Drain Water Irrigation on Trace Elements Load In Soil And Uptake By Vegetables. ... This polluted water not only contains organic matter and crop nutrients but also ... Plant samples were collected at maturity from all the monitoring points. ... (DO), Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD) ...

  15. Anomie and the "Brain Drain": A Sociological Explanation.

    Science.gov (United States)

    Karadima, Oscar

    The concept of anomie is proposed as one sociological variable that may explain the "brain drain" phenomenon (i.e., the movement of highly qualified personnel from their country of origin to another, most often a more developed, technologically advanced country). It is hypothesized that the higher the level of anomie found among…

  16. Amylase, lipase, and volume of drainage fluid in gastrectomy for the early detection of complications caused by pancreatic leakage.

    Science.gov (United States)

    Seo, Kyung Won; Yoon, Ki Young; Lee, Sang Ho; Shin, Yeon Myung; Choi, Kyung Hyun; Hwang, Hyun Yong

    2011-12-01

    Pancreatic leakage is a serious complication of gastrectomy due to stomach cancer. Therefore, we analyzed amylase and lipase concentrations in blood and drainage fluid, and evaluated the volume of drainage fluid to discern their usefulness as markers for the early detection of serious pancreatic leakage requiring reoperation after gastrectomy. From January 2001 to December 2007, we retrospectively analyzed data from 24,072 patient samples. We divided patients into two groups; 1) complications with pancreatic leakage (CG), and 2) no complications associated with pancreatic leakage (NCG). Values of amylase and lipase in the blood and drainage fluid, volume of the drainage fluid, and relationships among the volumes, amylase values, and lipase values in the drainage fluid were evaluated, respectively in the two groups. The mean amylase values of CG were significantly higher than those of NCG in blood and drainage fluid (P < 0.05). For lipase, statistically significant differences were observed in drainage fluid (P < 0.05). The mean volume (standard deviation) of the drained fluid through the tube between CG (n = 22) and NCG (n = 236) on postoperative day 1 were 368.41 (266.25) and 299.26 (300.28), respectively. There were no statistically significant differences between the groups (P = 0.298). There was a correlation between the amylase and lipase values in the drainage fluid (r = 0.812, P = 0.000). Among postoperative amylase and lipase values in blood and drainage fluid, and the volume of drainage fluid, the amylase in drainage fluid was better differentiated between CG and NCG than other markers. The volume of the drainage fluid did not differ significantly between groups.

  17. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    Science.gov (United States)

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  18. Improved simulation of poorly drained forests using Biome-BGC.

    Science.gov (United States)

    Bond-Lamberty, Ben; Gower, Stith T; Ahl, Douglas E

    2007-05-01

    Forested wetlands and peatlands are important in boreal and terrestrial biogeochemical cycling, but most general-purpose forest process models are designed and parameterized for upland systems. We describe changes made to Biome-BGC, an ecophysiological process model, that improve its ability to simulate poorly drained forests. Model changes allowed for: (1) lateral water inflow from a surrounding watershed, and variable surface and subsurface drainage; (2) adverse effects of anoxic soil on decomposition and nutrient mineralization; (3) closure of leaf stomata in flooded soils; and (4) growth of nonvascular plants (i.e., bryophytes). Bryophytes were treated as ectohydric broadleaf evergreen plants with zero stomatal conductance, whose cuticular conductance to CO(2) was dependent on plant water content. Individual model changes were parameterized with published data, and ecosystem-level model performance was assessed by comparing simulated output to field data from the northern BOREAS site in Manitoba, Canada. The simulation of the poorly drained forest model exhibited reduced decomposition and vascular plant growth (-90%) compared with that of the well-drained forest model; the integrated bryophyte photosynthetic response accorded well with published data. Simulated net primary production, biomass and soil carbon accumulation broadly agreed with field measurements, although simulated net primary production was higher than observed data in well-drained stands. Simulated net primary production in the poorly drained forest was most sensitive to oxygen restriction on soil processes, and secondarily to stomatal closure in flooded conditions. The modified Biome-BGC remains unable to simulate true wetlands that are subject to prolonged flooding, because it does not track organic soil formation, water table changes, soil redox potential or anaerobic processes.

  19. Perioperative lumbar drain utilization in transsphenoidal pituitary resection.

    Science.gov (United States)

    Alharbi, Shatha; Harsh, Griffith; Ajlan, Abdulrazag

    2018-01-01

    To evaluate lumbar drain (LD) efficacy in transnasal resection of pituitary macroadenomas in preventing postoperative cerebrospinal fluid (CSF) leak, technique safety, and effect on length of hospital stay. We conducted a retrospective data review of pituitary tumor patients in our institution who underwent surgery between December 2006 and January 2013. All patients were operated on for complete surgical resection of pituitary macroadenoma tumors. Patients were divided into 2 groups: group 1 received a preoperative drain, while LD was not preoperatively inserted in group 2. In cases of tumors with suprasellar extension with anticipation of high-flow leak, LD was inserted after the patient was intubated and in a lateral position. Lumbar drain was used for 48 hours, and the drain was removed if no leak was observed postoperatively. In documented postoperative CSF leak patients with no preoperative drain, the leak was treated by LD trial prior to surgical reconstruction. Cases in which leak occurred 6 months postoperatively were excluded. Our study population consisted of 186 patients, 99 women (53%) and 87 men (47%), with a mean age of 50.3+/-16.1 years. Complications occurred in 7 patients (13.7%) in group 1 versus 21 (15.5%) in group 2 (p=0.72). Postoperative CSF leak was observed in 1 patient (1.9%) in group 1 and 7 (5%) in group 2 (Fisher exact test=0.3). Length of hospital stay was a mean of 4.7+/-1.9 days in group 1 and a mean of 2.7+/-2.4 days in group 2 (pLD insertion is generally considered safe with a low risk of complications, it increases the length of hospitalization. Minor complications include headaches and patient discomfort.

  20. Leakage experiences with 1 MW steam generator

    International Nuclear Information System (INIS)

    Kanamori, A.; Kawara, M.; Sano, A.

    1975-01-01

    An 1 MW steam generator was tested from October, 1971 and completed with the first series of experiments by May, 1972 after 3600 hours of operation. During these tests, unextraordinary heat absorption was experienced in the downcomer region, which led to shortage of heat transfer area to attain the rated steam temperature and to one of the reasons of flow instabilities. The steam generator was disassembled to get test pieces for structure as well as material examinations and then it was reassembled to proceed the second series of tests. Before it was done, a modification was provided to insulate the downcomer region by putting a gas space around the downcomer tube. The gas space was provided by a dual tube and spacers were welded on the inner tube and an end plate was welded on upper parts between the two to seal the gap by means of fillet welding. After the modified steam generator was put into operation, water happened to leak into a sodium side two times through these additional welding spots for the gas insulation. This paper presents operating conditions and behaviors of monitors at the time of the leakages, identifications of leaked spots, an evaluation of causes and a treatment or a precaution for them

  1. Radiation leakage from linac electron applicator assembly

    International Nuclear Information System (INIS)

    Keys, R.A.; Purdy, J.A.

    1984-01-01

    The electron beam applicator system currently in use on the linear accelerator is constructed of light-weight fiberglass and aluminum. With an applicator in place on the accelerator, the photon collimator jaws are automatically set several centimeters greater than the electron field size projected at the patient's surface. To ensure that no regions of high dose levels exist outside the useful beam, ionization and film measurements were made to quantitate the amount of leakage radiation through the 10 cm x 10 cm and 25 cm x 25 cm applicators. In most regions, the ionization levels at the patient's surface were below 5% of the central axis dose. In one area for the 25 cm applicator, the percentage ionization was 8.5%, which could be reduced by the addition of a small piece of 1/8 inch thick lead. However, ionization levels on the outside surface of the applicator were found to be considerably higher at certain locations for the 25 cm applicator. Results for 6, 9, 12 and 20 MeV electrons are reported here

  2. A pleural vacuum relief device for pleural drain unit use in the hyperbaric environment.

    Science.gov (United States)

    Gelsomino, Marco; Tsouras, Theo; Millar, Ian; Fock, Andrew

    2017-09-01

    When a standard water-seal pleural drain unit (PDU) is used under hyperbaric conditions there are scenarios where excessive negative intrapleural pressure (IPP) and/or fluid reflux can be induced, risking significant morbidity. We developed and tested a pleural vacuum relief (PVR) device which automatically manages these risks, whilst allowing more rapid hyperbaric pressure change rates. The custom-made PVR device consists of a one-way pressure relief valve connected in line with a sterile micro filter selected for its specific flow capacity. The PVR device is designed for connection to the patient side sampling port of a PDU system, allowing inflow of ambient air whenever negative pressure is present, creating a small, controlled air leak which prevents excessive negative pressure. The hyperbaric performance of a Pleur-Evac A-6000 intercostal drain was assessed with and without this added device by measuring simulated IPP with an electronic pressure monitor connected at the patient end of the PDU. IPP readings were taken at 10, 15, 20 and 30 cmH₂O of suction (set on the drain unit) at compression rates of 10, 30, 60, 80, 90 and 180 kPa·min⁻¹ to a pressure of 280 kPa. At any compression rate of > 10 kPa·min⁻¹, the negative IPP generated by the Pleur-Evac A-6000 alone was excessive and resulted in back flow through the PDU water seal. By adding the PVR device, the generated negative IPP remains within a clinically acceptable range, allowing compression rates of at least 30 kPa·min⁻¹ with suction settings up to -20 cmH₂O during all phases of hyperbaric treatment. The PDU PVR device we have developed works well, minimising attendant workload and automatically avoiding the excessive negative IPPs that can otherwise occur. This device should only be used with suction.

  3. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  4. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  5. Developement of leakage localization technique by using acoustic signal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Jeon, J. H.; Seo, D. H.; Kim, K. W. [KAIST, Daejeon (Korea, Republic of)

    2010-07-15

    The objective of this research is to develop a leakage monitoring system for pipelines or valves in the secondary water system of a nuclear power plant. The system aims to detect the existence of leakage and to estimate the leak location, especially by utilizing the noise generated from the leak. It is safe, precise real-time alert system compared with the previous monitoring methods and tools such as the visual test and the thermal imaging camera. When there exists leakage in the pipeline or valves of nuclear power plant, the noise due to gas flow is radiated through leak region. That is, the secondary water system with leakage generates different noise from the system without leakage. This motivates us to measure and analyze the noise generated from the secondary water system, so as firstly to detect the existence of leakage, and secondly to estimate the leak location by using the noise source identification technique such as beamforming and acoustic holography. Especially the beamforming method models the signal from the noise source to estimate the location of source. Therefore, it is necessary to model the noise due to leakage which is dependent upon parameters. In the process of leak localization, the reflected wave due to interior walls and the measurement noise should be removed for the precise estimation. Therefore, we attempt to characterize the reflected wave and the measurement noise by modeling the interior sound field, thus to remove them and to localize the leak location with high precision

  6. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  7. The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA.

    Science.gov (United States)

    Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku

    2017-01-01

    Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

  8. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  9. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    Science.gov (United States)

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-12-10

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted.

  10. Investigation of radioactive contamination at non-radioactive drains of the Tsuruga Nuclear Power Station

    International Nuclear Information System (INIS)

    Koide, Hiroaki; Imanaka, Tetsuji; Ebisawa, Toru; Kawano, Shinji; Kobayashi, Keiji.

    1982-05-01

    In April, 1981, it was disclosed that a drainage area at the Tsuruga Nuclear Power Station was so much contaminated with radioactivites. Although Ministry of International Trade and Industry (MITI) officially provided an explanation of a process that resulted in the contamination, many problems remain unsolved on account of insufficient and limited investigations. The authors collected mud samples from contaminated manholes and examined radioactivities in them through the measurement of #betta#- and #betta#-spectra. Chemical separation of the samples was carried out in order to obtain precise concentration of radioactive cesium. Results are as follows: i) the concentration of radioactivities does not show monotonous decrease along the stream line but an anomalous peak at downstream manholes, ii) at the manhole specified No. 6 located rather downstream, 137 Cs concentration is significantly high and the composition of radioactive nuclides is quite different from that in the other manholes, and iii) additional radioactive contamination was observed in other manholes of non-radioactive drains which would not be influenced by the accident explained by MITI. Our present work has provided much more data than by MITI and made it clear that the overall data cnnot be consistent with the simple MITI explanation; a single radioactive release accident caused the disclosed contamination. It is concluded that non-radioactive water drains at the Tsuruga Nuclear Power Station had been under continual contamination. (author)

  11. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  12. Drained Lava Tubes and Lobes From Eocretaceous Paraná-Etendeka Province, Brazil

    Science.gov (United States)

    Waichel, B. L.; Lima, E. F. D.; Mouro, L. D.; Briske, D. R.; Tratz, E. B.

    2017-12-01

    The identification of lava tubes in continental flood basalt provinces (CFBP) is difficult and reports of preserved drained tubes and lobes are rare. The large extension of CFBP must be related to an efficient transport of lava and tubes are the most efficient mechanism to transport lava in insulated pathways, like observed in modern volcanic fields. Looking for caves in the central portion of Paraná-Etendeka Province, we discovered drained lava tubes (4) and lobes (6) in a volcanic sequence constituted by pahoehoe flows. Lava tubes are: Casa de Pedra, Perau Branco, Dal Pae and Pinhão. The Casa de Pedra tube system is composed of two principal chambers with similar dimensions, reaching up to 10 m long and 4.0 m high connected by a narrow passage. The general form of the chamber is hemispherical, with re-entrances of ellipsoidal shape probably formed by small lava lobes and collapse structures in the roof. The second chamber is connected with three secondary lava tubes. Columns in the cave are formed when the flowing lava separates in two lava channels that join again further down the system, forming and anastomosing tube network. Lateral lava benches and lava drainings at the walls are observed in secondary tubes. The general lava flow is to SW. The Perau Branco system is composed of five tubes with ellipsoidal openings. The main features are the long tubes that emerge from the small flattened chambers. One tube is more than 20 m long, with alternating circular and flattened ellipsoidal sections. The general lava flow is to NE. Pinhão tube is spherical with 3 meters diameter and 15 m long, with lava flow orientation to NW. This tube has a bottleneck shape with linings (up to 3 cm thick), which are observed in the roof and walls. Dal Pae Tube is 10 m long with an ellipsoidal opening, bottleneck shape and orientation to NE. The lava flow directions measured in the tubes is to SW (Casa de Pedra, Pinhão) and NE (Perau Branco, Dal Pae) and this pattern is related to

  13. Detection of underground water distribution piping system and leakages using ground penetrating radar (GPR)

    Science.gov (United States)

    Amran, Tengku Sarah Tengku; Ismail, Mohamad Pauzi; Ahmad, Mohamad Ridzuan; Amin, Mohamad Syafiq Mohd; Sani, Suhairy; Masenwat, Noor Azreen; Ismail, Mohd Azmi; Hamid, Shu-Hazri Abdul

    2017-01-01

    A water pipe is any pipe or tubes designed to transport and deliver water or treated drinking with appropriate quality, quantity and pressure to consumers. The varieties include large diameter main pipes, which supply entire towns, smaller branch lines that supply a street or group of buildings or small diameter pipes located within individual buildings. This distribution system (underground) is used to describe collectively the facilities used to supply water from its source to the point of usage. Therefore, a leaking in the underground water distribution piping system increases the likelihood of safe water leaving the source or treatment facility becoming contaminated before reaching the consumer. Most importantly, leaking can result in wastage of water which is precious natural resources. Furthermore, they create substantial damage to the transportation system and structure within urban and suburban environments. This paper presents a study on the possibility of using ground penetrating radar (GPR) with frequency of 1GHz to detect pipes and leakages in underground water distribution piping system. Series of laboratory experiment was designed to investigate the capability and efficiency of GPR in detecting underground pipes (metal and PVC) and water leakages. The data was divided into two parts: 1. detecting/locating underground water pipe, 2. detecting leakage of underground water pipe. Despite its simplicity, the attained data is proved to generate a satisfactory result indicating GPR is capable and efficient, in which it is able to detect the underground pipe and presence of leak of the underground pipe.

  14. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  15. 'Brain drain' from Serbia: One face of globalization of education?

    Directory of Open Access Journals (Sweden)

    Avramović Zoran

    2012-01-01

    Full Text Available In this paper we point out the role of the practice and ideology of globalization in brain drain process from Serbia. The listed data are based on the large-scale departure of highly educated persons from Serbia to the counties of West Europe and the USA. The dynamics, proportions and tendencies are analysed the role of the educational system in the process of departure of highly educated people and the reasons and consequences of the departure of scientist and engineering experts. In this article, education policy as state financial support are critical analysed. For Serbia, as the relatively undeveloped country in the middle of the modernization processes, this process has far-reaching effects on the social development. So, here we implied the possible solutions for the problem of brain drain.

  16. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  17. Measurement for the MLC leaf velocity profile by considering the leaf leakage using a radiographic film

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    A method to measure the velocity profile of a multi-leaf collimator (MLC) leaf along its travel range using a radiographic film is reported by considering the intra-leaf leakage. A specific dynamic MLC field with leaves travelling from the field edge to the isocentre line was designed. The field was used to expose a radiographic film, which was then scanned, and the dose profile along the horizontal leaf axis was measured. The velocity at a sampling point on the film can be calculated by considering the horizontal distance between the sampling point and the isocentre line, dose at the sampling point, dose rate of the linear accelerator, the total leaf travel time from the field edge to isocentre line and the pre-measured dose rate of leaf leakage. With the leaf velocities and velocity profiles for all MLC leaves measured routinely, a comprehensive and simple QA for the MLC can be set up to test the consistency of the leaf velocity performance which is essential to the IMRT delivery using a sliding window technique. (note)

  18. Reduction in wick drain effectiveness with spacing for Utah silts and clays.

    Science.gov (United States)

    2012-04-01

    Although decreasing the spacing of vertical drains usually decreases the time for consolidation, previous field tests have shown that there is a critical drain spacing for which tighter spacing does not decrease the time for consolidation. This...

  19. Brain drain: a challenge to global mental health

    OpenAIRE

    Oladeji, Bibilola D.; Gureje, Oye

    2016-01-01

    The brain drain of medical professionals from lower-income to higher-income countries contributes to the current inequity that characterises access to mental healthcare by those in need across the world and hinders efforts to scale up mental health services in resource-constrained settings, especially in Nigeria and other West African countries. The migration of skilled workers is driven by a combination of the globalisation of the labour market and the ability of highly resourced countries t...

  20. Outcome in Chronic Subdural Hematoma After Subdural vs. Subgaleal Drain

    International Nuclear Information System (INIS)

    Ishfaq, A.

    2017-01-01

    Objective: To compare the outcome after surgery for chronic subdural hematoma when the drain is placed in subdural space or subgaleal space. Study Design: Quasi experimental study. Place and Duration of Study: Combined Military Hospital, Lahore, from July 2015 to June 2016. Methodology: Patients with chronic subdural hematoma of both genders and age, ranging between 55 to 85 years, were included. Patients on antiplatelet/anticoagulant therapy and acute on chronic subdural hematoma were excluded. Patients were divided in two equal groups each depending on whether drain was placed in subgaleal space (Group 1), and subdual space (Group 2), (n=31 patients each). Patients were positioned flat in bed after surgery. Clinical and radiological parameters and clinical outcome were compared between the two groups. Statistical test with significance of p <0.05 was utilized using Statistical Package of Social Sciences (SPSS version 17). Results: Median age of the 62 patients was 72 +-12.5 years. Headache was the most common symptom reported in both groups, (n=47,75.8%) patients. Median thickness of hematoma was 15 +-6.5 mm. Patients with subdural drain placement had more complications such as pneumocephalus 11 (35.4%) vs. 6 (19.3%), and intracerebral hemorrhage 4 (12.9%) vs. 2 (6.4%). Clinical outcome was good in both groups 27 (87%) in Group 1 and 28 (90%) in Group 2. Conclusion: Patients of both groups had good outcome after surgery. Complications like pneumocephalus and intracerebral hemorrhage were more common in subdural location of drain, though not reaching statistically significance level to favor one technique over another. (author)

  1. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    OpenAIRE

    Xiao Guo; Kang-He Xie; Yue-Bao Deng

    2014-01-01

    This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1) the flow with the threshold gradie...

  2. Globalization and migration: A "unified brain drain" model

    OpenAIRE

    Brezis, Elise S.; Soueri, Ariel

    2012-01-01

    Globalization has led to a vast flow of migration of workers but also of students. The purpose of this paper is to analyze the migration of individuals encompassing decisions already at the level of education. We develop a unified brain drain model that incorporates the decisions of an individual vis - à - vis both education and migration. In the empirical part, this paper addresses international flows of migration within the EU and presents strong evidence of concentration of students in cou...

  3. Leakage potential through mechanical penetrations in a severe accident environment

    International Nuclear Information System (INIS)

    Koenig, L.N.

    1986-01-01

    This paper reviews the findings of an ongoing program, Integrity of Containment Penetrations Under Severe Accident Loads. The program is concerned with the leakage modes as well as the magnitude of leakage through mechanical penetrations in a containment building subject to a severe accident. Seal and gasket tests are used to evaluate the effect of radiation aging, thermal aging, seal geometry, and seal squeeze on seals and gaskets subjected to a hypothesized severe accident. The effects on leakage of the structural response of equipment hatches, personnel airlocks, and drywell heads subjected to severe accident pressures are studied by experiments and analyses. The data gathered during this program will be used to develop methodologies for predicting leakage

  4. N13 - based reactor coolant pressure boundary leakage system

    International Nuclear Information System (INIS)

    Dissing, E.; Marbaeck, L.; Sandell, S.; Svansson, L.

    1980-05-01

    A system for the monitoring of leakage of coolant from the reactor coolant pressure boundary and auxiliary systems to the reactor containment, based on the detection of the N13 content in the atmosphere, has been tested. N13 is produced from the oxyegen of the reactor water via the recoil photon nuclear process H1 + 016 + He4. The generation of N13 is therefore independent of fuel element leakage and of the corrosion product content in the water. In the US AEC regulatory guide 1.45 has a leakage increase of 4 liter/ min been suggested as the response limit. The experiments carried out in Ringhals indicate, that with the accomplishment of minor improvements in the installation, a 4 liter/min leakage to the containment will give rise to a signal with a random error range of +- 0.25 liter/min, 99.7 % confidence level. (author)

  5. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  6. Fractal modeling of fluidic leakage through metal sealing surfaces

    Science.gov (United States)

    Zhang, Qiang; Chen, Xiaoqian; Huang, Yiyong; Chen, Yong

    2018-04-01

    This paper investigates the fluidic leak rate through metal sealing surfaces by developing fractal models for the contact process and leakage process. An improved model is established to describe the seal-contact interface of two metal rough surface. The contact model divides the deformed regions by classifying the asperities of different characteristic lengths into the elastic, elastic-plastic and plastic regimes. Using the improved contact model, the leakage channel under the contact surface is mathematically modeled based on the fractal theory. The leakage model obtains the leak rate using the fluid transport theory in porous media, considering that the pores-forming percolation channels can be treated as a combination of filled tortuous capillaries. The effects of fractal structure, surface material and gasket size on the contact process and leakage process are analyzed through numerical simulations for sealed ring gaskets.

  7. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... completion of the operation the patients were randomized in two groups with and without a transanal stent. RESULTS: A clinically significant leakage was diagnosed in 25 patients (13%). No significant difference was found 17 of 98 patients with a stent and 8 of 96 without (P = 0.09), or in 9 of 44 ileostomy...... patients with a stent and in 3 of 45 without (P = 0.07). Several leaks over a short time led to an interim analysis after inclusion of 194 of 448 planned patients. The analysis showed no significant protective effect of the stent, and more leakages in the stent group, although not statistically significant...

  8. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  9. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  10. Leakage Testing for Different Adhesive Systems and Composites to ...

    African Journals Online (AJOL)

    2015-11-16

    Nov 16, 2015 ... resin composite, the fifth group – two‑stage SE adhesive applied and cavities filled with ... KEYWORDS: Adhesives, composite, evaluation, leakage ... the glass ionomers. ... systems are realized in one or two clinical step(s).[5].

  11. Anastomotic leakage after laparoscopic total mesorectal excision for low rectal cancer

    Directory of Open Access Journals (Sweden)

    Matej Skrovina

    2011-03-01

    Full Text Available Aim: Our single centre comparative study is focused on perioperative outcomes of laparoscopic total mesorectal excision in patients with middle and low rectal cancer with attention to complications of double stapling coloanal anastomosis with and without protective ileostomy. Material and methods: From 1 January 2005 to 30 June 2008, 349 patients with rectal cancer underwent surgery at our centre. Of these, 114 patients (41 women and 73 men with middle and low rectal cancer ( 12 cm from the anal verge after laparoscopic resection with total mesorectal excision and primary coloanal anastomosis were included in the study. There were 64 patients with primary anastomosis without protective ileostomy in the first group, and 50 patients with primary protective ileostomy in the second one. Anastomotic leakage was defined as presence of stapler line dehiscence, presacral abscess or rectovaginal fistula.Results: Coloanal anastomotic leakage was present in 11.4% of cases (13 of 114 patients. In the no stoma group leakage was present in 17.2% of cases, in the stoma group in 4.0% of cases. Reoperation was needed in 9.4% (6 of 64 in the no stoma group and in 2.0% (1 of 50 in the stoma group. Stage of disease was found to be another factor influencing anastomotic healing. There was no significant difference between groups in relation to preoperative chemoradiotherapy, sex, body mass index, ASA score, age, time of surgery and tumour location in our study. Conclusions: Protective loop ileostomy significantly reduces the presence of symptomatic anastomotic leakage of double stapling coloanal anastomosis after laparoscopic total mesorectal excision in patients with low rectal cancer.

  12. Theoretical computation background for transformation of foundations using pile drains

    Directory of Open Access Journals (Sweden)

    Ter-Martirosyan Zaven

    2017-01-01

    Full Text Available In the design of foundations for buildings and structures of various purposes, including improved risk, weak water-saturated clay soils with low mechanical characteristics are often found on a construction site. One of the possible ways of using them as a foundation is to seal them in various ways, including using pile drains of sand or rock stone material that are capable of both absorbing the load at the base and accelerating the process of filtration consolidation. This paper describes an analytical solution to the problem of interaction between the pile and the mattress with the surrounding soil of the foundation, taking into account the possibility of expanding the pile shaft. Solutions are obtained for determining the stresses in the shaft of the pile drain and in the soil under the mattress. The solution takes into account the influence of the pre-stressed state of the foundation after compaction on the formation of a stress-strain state during the erection and operation of structures. The solutions are relevant for consolidating pile drains made of rubble or for jet grouting piles, the rigidity of which is comparable to the rigidity of the surrounding soil. The paper describes the technique for determining the characteristics of the strength and deformability of the converted foundation and the results of large-scale tests at the experimental site for the construction of a large energy facility in Russia.

  13. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    OpenAIRE

    Gonzalo García-Ros; Iván Alhama; Manuel Cánovas

    2018-01-01

    The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018), a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD) and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulat...

  14. Detecting the leakage source of a reservoir using isotopes.

    Science.gov (United States)

    Yi, Peng; Yang, Jing; Wang, Yongdong; Mugwanezal, Vincent de Paul; Chen, Li; Aldahan, Ala

    2018-07-01

    A good monitoring method is vital for understanding the sources of a water reservoir leakage and planning for effective restoring. Here we present a combination of several tracers ( 222 Rn, oxygen and hydrogen isotopes, anions and temperature) for identification of water leakage sources in the Pushihe pumped storage power station which is in the Liaoning province, China. The results show an average 222 Rn activity of 6843 Bq/m 3 in the leakage water, 3034 Bq/m 3 in the reservoir water, and 41,759 Bq/m 3 in the groundwater. Considering that 222 Rn activity in surface water is typically less than 5000 Bq/m 3 , the low level average 222 Rn activity in the leakage water suggests the reservoir water as the main source of water. Results of the oxygen and hydrogen isotopes show comparable ranges and values in the reservoir and the leakage water samples. However, important contribution of the groundwater (up to 36%) was present in some samples from the bottom and upper parts of the underground powerhouse, while the leakage water from some other parts indicate the reservoir water as the dominant source. The isotopic finding suggests that the reservoir water is the main source of the leakage water which is confirmed by the analysis of anions (nitrate, sulfate, and chloride) in the water samples. The combination of these tracer methods for studying dam water leakage improves the accuracy of identifying the source of leaks and provide a scientific reference for engineering solutions to ensure the dam safety. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. LMFBR technology. FFTF cover-gas leakage calculation

    International Nuclear Information System (INIS)

    Deboi, H.

    1974-01-01

    The FFTF LMFBR is intended to have a near zero release of radioactive gases during normal reactor operation with 1% failed fuel. This report presents calculations which provide an approximation of these cover gas leakages. Data from ongoing static and dynamic seal leak tests at AI are utilized. Leakage through both elastomeric and metallic seals in all sub-assemblies and penetrations comprising the reactor cover gas containment during reactor operation system are included

  16. Drain site evisceration of fallopian tube, another reason to discourage abdominal drain: report of a case and brief review of literature.

    Science.gov (United States)

    Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet

    2012-04-01

    Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.

  17. Field size dependent mapping of medical linear accelerator radiation leakage

    International Nuclear Information System (INIS)

    Vu Bezin, Jérémi; De Vathaire, Florent; Diallo, Ibrahima; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric

    2015-01-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies. (paper)

  18. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  19. The Simple Urine Bag as Wound Drain Post-Craniotomy in a Low ...

    African Journals Online (AJOL)

    Methods: A 4-year prospective cohort study of the effectiveness, outcome with use and complications of the Uribag as post craniotomy wound drain in a consecutive cohort of neurosurgical patients. Data analyzed include the patients' brief demographics; the types of cranial surgery in which drain was used; the drain ...

  20. 76 FR 62605 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Science.gov (United States)

    2011-10-11

    ... the VGB Act defines an ``unblockable drain'' as ``a drain of any size and shape that a human body... intentions. They claim that for this reason, backup systems are necessary, and a swimming pool or spa with a... of an ``unblockable drain,'' at 16 CFR 1450.2(b) and believe it was in error. Regardless of the size...

  1. Draining after breast reduction: a randomised controlled inter-patient study

    NARCIS (Netherlands)

    Corion, Leonard U. M.; Smeulders, Mark J. C.; van Zuijlen, Paul P. M.; van der Horst, Chantal M. A. M.

    2009-01-01

    One hundred and seven bilateral breast reductions were prospectively randomised during surgery to receive or not receive wound drains. Fifty-five patients were randomised to have a drain and 52 to not have a drain. There was no statistical difference in the number of complications between the

  2. An economic perspective on Malawi's medical "brain drain"

    Directory of Open Access Journals (Sweden)

    Mohiddin Abdu

    2006-12-01

    Full Text Available Abstract Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production" of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a

  3. An economic perspective on Malawi's medical "brain drain"

    Science.gov (United States)

    Record, Richard; Mohiddin, Abdu

    2006-01-01

    Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production") of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance) to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a closer look at the evidence

  4. Leakage localization with an acoustic array that covers a wide area for pipeline leakage monitoring in a closed space

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Su [Center for Safety Measurements, Division of Metrology for Quality of Life, Korea Research institute of Standards and Science, Daejeon (Korea, Republic of); Jeon, Jong Hoon [Hyundai Heavy Industry Co.,Ltd., Ulsan (Korea, Republic of); Park, Jin Ho [Korea Atomiv Energy Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beam forming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beam forming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.

  5. [Bile leakage after liver resection: A retrospective cohort study].

    Science.gov (United States)

    Menclová, K; Bělina, F; Pudil, J; Langer, D; Ryska, M

    2015-12-01

    Many previous reports have focused on bile leakage after liver resection. Despite the improvements in surgical techniques and perioperative care the incidence of this complication rather keeps increasing. A number of predictive factors have been analyzed. There is still no consensus regarding their influence on the formation of bile leakage. The objective of our analysis was to evaluate the incidence of bile leakage, its impact on mortality and duration of hospitalization at our department. At the same time, we conducted an analysis of known predictive factors. The authors present a retrospective review of the set of 146 patients who underwent liver resection at the Department of Surgery of the 2nd Faculty of Medicine of the Charles University and Central Military Hospital Prague, performed between 20102013. We used the current ISGLS (International Study Group of Liver Surgery) classification to evaluate the bile leakage. The severity of this complication was determined according to the Clavien-Dindo classification system. Statistical significance of the predictive factors was determined using Fishers exact test and Students t-test. The incidence of bile leakage was 21%. According to ISGLS classification the A, B, and C rates were 6.5%, 61.2%, and 32.3%, respectively. The severity of bile leakage according to the Clavien-Dindo classification system - I-II, IIIa, IIIb, IV and V rates were 19.3%, 42%, 9.7%, 9.7%, and 19.3%, respectively. We determined the following predictive factors as statistically significant: surgery for malignancy (pBile leakage significantly prolonged hospitalization time (pbile leakage the perioperative mortality was 23 times higher (pBile leakage is one of the most serious complications of liver surgery. Most of the risk factors are not easily controllable and there is no clear consensus on their influence. Intraoperative leak tests could probably reduce the incidence of bile leakage. In the future, further studies will be required to improve

  6. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  7. Iatrogenic Perforation of the Left Ventricle during Insertion of a Chest Drain

    OpenAIRE

    Kim, Dongmin; Lim, Seong-Hoon; Seo, Pil Won

    2013-01-01

    Chest draining is a common procedure for treating pleural effusion. Perforation of the heart is a rare often fatal complication of chest drain insertion. We report a case of a 76-year-old female patient suffering from congestive heart failure. At presentation, unilateral opacity of the left chest observed on a chest X-ray was interpreted as massive pleural effusion, so an attempt was made to drain the left pleural space. Malposition of the chest drain was suspected because blood was draining ...

  8. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, R.; Harrell, J.

    1996-12-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves.

  9. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    International Nuclear Information System (INIS)

    Fuller, R.; Harrell, J.

    1996-01-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves

  10. A retrospective study of the use of active suction wound drains in dogs and cats.

    Science.gov (United States)

    Bristow, P C; Halfacree, Z J; Baines, S J

    2015-05-01

    To report indications for use and complications associated with commonly used closed active suction wound drains in a large number of clinical cases. Retrospective review of medical case records (from 2004 to 2010) for dogs and cats that had a closed active suction drain placed into a wound. Only the four most common drain types were included: Mini Redovac®, Redovac®, Jackson Pratt® and Wound Evac®. Two hundred and fifty-three drains were placed in 33 cats and 195 dogs. Mini Redovac drains were used most frequently in cats (76 · 5%) and Redovac drains in dogs (54 · 3%). The infection rate for clean surgeries in dogs was 15 · 6% (unattainable in cats). Major complications occurred in four dogs; minor complications occurred in 12 drains in cats (35 · 3%), and in 74 drains in dogs (33 · 8%). There was no statistically significant association between the type of drain and complication rate for either species. Although closed active suction drains can be used with low risk of major complications, they lead to a high rate of infection in clean surgeries in dogs. It is recommended that such drains are kept in place for the shortest time possible and that strict asepsis is adhered to both during placement and management. © 2015 British Small Animal Veterinary Association.

  11. Comparison of a large and small-calibre tube drain for managing spontaneous pneumothoraces.

    Science.gov (United States)

    Benton, Ian J; Benfield, Grant F A

    2009-10-01

    To compare treatment success of large- and small-bore chest drains in the treatment of spontaneous pneumothoraces the case-notes were reviewed of those admitted to our hospital with a total of 73 pneumothoraces and who were treated by trainee doctors of varying experience. Both a large- and a small-bore intercostal tube drain system were in use during the two-year period reviewed. Similar pneumothorax profile and numbers treated with both drains were recorded, resulting in a similar drain time and numbers of successful and failed re-expansion of pneumothoraces. Successful pneumothorax resolution was the same for both drain types and the negligible tube drain complications observed with the small-bore drain reflected previously reported experiences. However the large-bore drain was associated with a high complication rate (32%) with more infectious complications (24%). The small-bore drain was prone to displacement (21%). There was generally no evidence of an increased failure and morbidity, reflecting poorer expertise, in the non-specialist trainees managing the pneumothoraces. A practical finding however was that in those large pneumothoraces where re-expansion failed, the tip of the drain had not been sited at the apex of the pleural cavity irrespective of the drain type inserted.

  12. Evisceration of Appendix through the Drain Site: A Rare Case Report.

    Science.gov (United States)

    Ravishankaran, Praveen; Rajamani, A

    2013-06-01

    Placing a drain after surgery is a usual procedure in any emergency abdominal operation. The drain is removed as soon as its purpose of draining the intraabdominal collection in served. Evisceration of intraabdominal organs through the drain site is a rare occurance. This case report is about an 12 year old girl who was admitted with blunt trauma abdomen. After completion of emergency laparotomy a drain was placed in the right lower quadrant. When the drain was removed on the 6th post operative day, the appendix eviscerated out of the drain site. The wound was extended a little and an appendectomy was done. This case is presented for its rarity as only two similar instances have been reported in literature so far.

  13. India: 'brain drain' or the migration of talent?

    Science.gov (United States)

    Oommen, T K

    1989-09-01

    2 views on "brain drain" exist: 1) LDCs lose their enormous investments on higher education when skilled people migrate to other countries and 2) LDCs are exaggerating the problem and only a few skilled people migrate at 1 time. India does not completely lose its investment in education when professionals migrate, since the migrants still contribute to knowledge and also send remittances to relatives in India. Unemployed educated people would cause a greater drain on India's resources than educated migrants. The author prefers the phrase migration of talent to brain drain, since the former indicates a 2-way movement. Most migrants from LDCs are students. About 11,000 university graduates leave India every year for advanced study and/or work. A conservative estimate is that 2500 will remain abroad permanently. Most professionals who migrate go to the US and Canada. Factors promoting migration include 1) unemployment, 2) immigration rules, 3) colonial links, 4) financial incentives and material benefits, 5) pursuit of higher education, 6) improvement of working conditions and facilities, 7) avoidance of excessive bureaucratic procedures, and 8) compensation for the mismatch between Indian education and employment. Reasons for returning to India include 1) deference to wives who were unable to adjust to a foreign way of life, 2) contributing to Indian development, and 3) racial discrimination. It will probably not be possible to lure back migrants who left for material reasons. Attractive job offers could entice back those who left for advanced training. To encourage the return of those who left to pursue high quality research, India must 1) increase expenditure on research and development, possibly through the private industrial sector, 2) promote travel to other countries for professional enrichment, and 3) improve conditions of research work. The article concludes with an analysis of migration of talent from 3 perspectives: 1) the individual, 2) the nation

  14. Endoscopic endonasal skull base surgery: advantages, limitations, and our techniques to overcome cerebrospinal fluid leakage: technical note.

    Science.gov (United States)

    Ishii, Yudo; Tahara, Shigeyuki; Teramoto, Akira; Morita, Akio

    2014-01-01

    In recent years, resections of midline skull base tumors have been conducted using endoscopic endonasal skull base (EESB) approaches. Nevertheless, many surgeons reported that cerebrospinal fluid (CSF) leakage is still a major complication of these approaches. Here, we report the results of our 42 EESB surgeries and discuss the advantages and limits of this approach for resecting various types of tumors, and also report our technique to overcome CSF leakage. All 42 cases involved midline skull base tumors resected using the EESB technique. Dural incisions were closed using nasoseptal flaps and fascia patch inlay sutures. Total removal of the tumor was accomplished in seven pituitary adenomas (33.3%), five craniopharyngiomas (62.5%), five tuberculum sellae meningiomas (83.3%), three clival chordomas (100%), and one suprasellar ependymoma. Residual regions included the cavernous sinus, the outside of the intracranial part of the internal carotid artery, the lower lateral part of the posterior clivus, and the posterior pituitary stalk. Overall incidence of CSF leakage was 7.1%. Even though the versatility of the approach is limited, EESB surgery has many advantages compared to the transcranial approach for managing mid-line skull base lesions. To avoid CSF leakage, surgeons should have skills and techniques for complete closure, including use of the nasoseptal flap and fascia patch inlay techniques.

  15. Processing method for drained water containing ethanol amine

    International Nuclear Information System (INIS)

    Wakuta, Kuniharu; Ogawa, Naoki; Sagawa, Hiroshi; Kamiyoshi, Hideki; Fukunaga, Kazuo; Iwamoto, Ken; Miki, Tsuyoshi; Hirata, Toshio

    1998-01-01

    Drained water containing ethanol amine is processed with microorganisms such as hydrazine resistant denitrification bacteria in a biodegrading vessel (A) in the coexistence of nitrous ions and/or nitric ions under an anaerobic condition, and then it is processed with microorganisms such as nitrification bacteria in another biotic oxidation vessel (B) under an aerobic condition to generate the coexistent nitrate ion and/or nitric ion, and returned to the biodegrading vessel (A). Further, they are exposed to air or incorporated with an oxidant and optionally a copper compound such as copper sulfate as a catalyst is added in a step of removing hydrazine. (T.M.)

  16. Right superior vena cava draining into the left atrium

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); Batisse, Alain [Institut de Puericulture et de Perinatalogie, Paris (France); Vouhe, Pascal [University Rene Descartes-Paris 5, Department of Paediatric Cardiac Surgery, Hopital Necker-Enfants Malades, Paris (France); Ou, Phalla [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker-Enfants Malades, Paris (France)

    2008-08-15

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  17. Consequences assessment for fuel channel failure with consequential moderator drain

    International Nuclear Information System (INIS)

    Wahba, N.N.; Bayoumi, M.H.

    2002-01-01

    This paper documents the consequences of spontaneous pressure tube/consequential calandria tube rupture followed by the ejection of end fittings (as a result of guillotine failure of pressure tube) leading to the drain of the moderator. The event is postulated to occur in conjunction with an independent failure of Emergency Coolant Injection System (ECIS). The results of the detailed consequence assessments are used to propose a course of action to mitigate the consequences of such an event. A methodology based on a lumped-parameter model was developed to assess the consequences of the postulated event. (author)

  18. Interior drains for open pit disposal of uranium mill tailings

    International Nuclear Information System (INIS)

    Staub, W.P.

    1978-01-01

    A conceptualized interior drainage system is presented for reducing the environmental impact on natural groundwater by disposal of uranium mill tailings in the mined-out open pit. The evaporation/seepage ratio can be increased through the use of interior drains, long-term monitoring of groundwater quality can be eliminated, and the open pit will not require an extensive liner. Other advantages not related to groundwater are: control of fugitive dust and radon emanation during mill operations and timely reclamation after the impoundment is filled with tailings

  19. Right superior vena cava draining into the left atrium

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien; Batisse, Alain; Vouhe, Pascal; Ou, Phalla

    2008-01-01

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  20. Application of Prefabricated Vertical Drain in Soil Improvement

    Directory of Open Access Journals (Sweden)

    Tedjakusuma B.

    2012-01-01

    Full Text Available Although the use of Prefabricated Vertical Drain (PVD in soil improvement is not new, this paper is interesting since it gives the full spectrum from preliminary design stage; trial embankment and pilot test to final soil improvement. The final installation of the PVD was based on the soil investigation report and the results of instrumentation monitoring. Finally, using back analysis, vertical and horizontal coefficients of consolidation and compression index can be determined, which can be applied to predict a more accurate prediction of settlement.

  1. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  2. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  3. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  4. New Method for Leakage Detection by Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Attari

    2018-03-01

    Full Text Available Nowadays water loss has been turned into a global concern and on the other hand the demand for water is increasing. This problem has made the demand management and consumption pattern reform necessary. One of the most important methods for managing water consumption is to decrease the water loss. In this study by using neural networks, a new method is presented to specify the location and quantity of leakages in water distribution networks.  In this method, by producing the training data and applying it to neural network, the network is able to determine approximate location and quantity of nodal leakage with receiving the nodal pressure. Production of training data is carried out by applying assumed leakage to specific nodes in the network and calculating the new nodal pressures. The results show that by minimum use of hydraulic data taken from pressures, not only this method can determine the location of nodal leakages, but also it can specify the amount of leakage on each node with reasonable accuracy.

  5. Gas-path leakage seal for a gas turbine

    Science.gov (United States)

    Wolfe, C.E.; Dinc, O.S.; Bagepalli, B.S.; Correia, V.H.; Aksit, M.F.

    1996-04-23

    A gas-path leakage seal is described for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the ``plane`` of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member. 4 figs.

  6. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  7. Risk factors, treatment and impact on outcomes of bile leakage after hemihepatectomy.

    Science.gov (United States)

    Zheng, Si-Ming; Li, Hong; Li, Gen-Cong; Yu, Dan-Song; Ying, Dong-Jian; Zhang, Bin; Lu, Cai-De; Zhou, Xin-Hua

    2017-07-01

    Risk factors for bile leakage after hemihepatectomy are unknown. A prospectively maintained database review identified patients undergoing hemihepatectomy between 1 January 2009 and 30 September 2014. Patients were divided into B/C and non-B/C bile leakage groups. Risk factors for bile leakage were predicted and assessments of their impact on patients were made. Bile leakage occurred in 91 of the 297 patients (30.6%); 64 cases were classified as grade B bile leakage (21.5%) and three cases as grade C bile leakage (1.0%). Multivariate analysis confirmed that elevated preoperative alanine transaminase (ALT), positive bile culture during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery were risk factors for B/C grade bile leakage (P bile leakage (P bile leakage (P bile leakage group were higher than those in the non-B/C bile leakage group (P bile leakage group also required prolonged hospitalization (P 0.05). Patient with elevated preoperative ALT, positive bile cultures during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery are more likely to complicate bile leakage. We should use biliary drainage such as preoperative PTBD, ENBD or intraoperative Kehr's T-tube drainage to reduce and treat bile leakage in patients with high risk of bile leakage. © 2015 Royal Australasian College of Surgeons.

  8. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  9. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  10. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  11. Research on leakage detection of nuclear power station primary loop

    International Nuclear Information System (INIS)

    Cao Shengquan; Yang Jicai; Li Jianjun; Dong Zhijuan; Ren Juyan; Zhang Pinyuan

    1993-01-01

    The sensor of leak-detection system is a special humidity-sensitive element. In this system, the collection and treatment of detected data, and the leakage alarm are controlled by a simple board computer. The three parameters A, B and C are set up in this system, and the alarm will give out when signal surpasses values of B and C at the same time. The effects of environment humidity and temperature on collection of detected data are considered, and the leakage alarm is reliable. When the leakage rate of water at 320 degree C and 12.2 MPa is 0.3 g/min, the alarm signal will sent out within 5 s

  12. Leakage of pressurized gases through unlined concrete containment structures

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.

    1983-01-01

    Eight reinforced concrete specimens were fabricated and subjected to tensile membrane forces and air pressure to study the air leakage characteristics in cracked reinforced concrete members. A mathematical expression for the rate of pressurized air flowing through an idealized crack is presented. The mathematical expression is refined by using the experimental data to describe the air flow rate through any given crack pattern. Graphical charts are also presented for the calculation of the air leakage rate through concrete cracks. The concept of equivalent crack width for a given crack pattern is introduced. The mathematical expression and graphical charts are modified to include this equivalent crack width concept. The proposed technique is applicable for the prediction of the leakage from concrete containment structures or any similar structures due to high internal pressure sufficient to initiate cracking. (orig.)

  13. Suppression of tunneling leakage current in junctionless nanowire transistors

    International Nuclear Information System (INIS)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-01-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out. (paper)

  14. Suppression of tunneling leakage current in junctionless nanowire transistors

    Science.gov (United States)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-12-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out.

  15. On the Connection between Leakage Tolerance and Adaptive Security

    DEFF Research Database (Denmark)

    Nielsen, Jesper Buus; Venturi, Daniele; Zottarel, Angela

    2013-01-01

    We revisit the context of leakage-tolerant interactive protocols as defined by Bitanski, Canetti and Halevi (TCC 2012). Our contributions can be summarized as follows: For the purpose of secure message transmission, any encryption protocol with message space M and secret key space SK tolerating...... at the end of the protocol execution, if and only if the protocol has passive adaptive security against an adaptive corruption of one party at the end of the protocol execution. This shows that as soon as a little leakage is tolerated, one needs full adaptive security. In case more than one party can...... be corrupted, we get that leakage tolerance is equivalent to a weaker form of adaptivity, which we call semi-adaptivity. Roughly, a protocol has semi-adaptive security if there exist a simulator which can simulate the internal state of corrupted parties, however, such a state is not required...

  16. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    Directory of Open Access Journals (Sweden)

    Xiao Guo

    2014-01-01

    Full Text Available This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1 the flow with the threshold gradient would not occur instantaneously throughout the whole unit cell. Rather, it gradually occurs from the vertical drain to the outside; (2 the moving boundary would never reach the outer radius of influence if R+1

  17. Global estimates of high-level brain drain and deficit.

    Science.gov (United States)

    Ioannidis, John P A

    2004-06-01

    Brain drain, the international migration of scientists in search of better opportunities, has been a long-standing concern, but quantitative measurements are uncommon and limited to specific countries or disciplines. We need to understand brain drain at a global level and estimate the extent to which scientists born in countries with low opportunities never realize their potential. Data on 1523 of the most highly cited scientists for 1981-1999 are analyzed. Overall, 31.9% of these scientists did not reside in the country where they were born (range 18.1-54.6% across 21 different scientific fields). There was great variability across developed countries in the proportions of foreign-born resident scientists and emigrating scientists. Countries without a critical mass of native scientists lost most scientists to migration. This loss occurred in both developed and developing countries. Adjusting for population and using the U.S. as reference, the number of highly cited native-born scientists was at least 75% of the expected number in only 8 countries other than the U.S. It is estimated that approximately 94% of the expected top scientists worldwide have not been able to materialize themselves due to various adverse conditions. Scientific deficit is only likely to help perpetuate these adverse conditions.

  18. Computational Investigation of Novel Tip Leakage Mitigation Methods for High Pressure Turbine Blades

    Science.gov (United States)

    Ibrahim, Mounir; Gupta, Abhinav; Shyam, Vikram

    2014-01-01

    This paper presents preliminary findings on a possible approach to reducing tip leakage losses. In this paper a computational study was conducted on the Energy Efficient Engine (EEE) High Pressure Turbine (HPT) rotor tip geometry using the commercial numerical solver ANSYS FLUENT. The flow solver was validated against aerodynamic data acquired in the NASA Transonic Turbine Blade Cascade facility. The scope of the ongoing study is to computationally investigate how the tip leakage and overall blade losses are affected by (1) injection from the tip near the pressure side, (2) injection from the tip surface at the camber line, and (3) injection from the tip surface into the tip separation bubble. The objective is to identify the locations on the tip surface at which to place appropriately configured blowing keeping in mind the film cooling application of tip blowing holes. The validation was conducted at Reynolds numbers of 85,000, 343,000, and 685,000 and at engine realistic flow conditions. The coolant injection simulations were conducted at a Reynolds number of 343,000 based on blade chord and inlet velocity and utilized the SST turbulence model in FLUENT. The key parameters examined are the number of jets, jet angle and jet location. A coolant to inlet pressure ratio of 1.0 was studied for angles of +30 deg, -30 deg, and 90 deg to the local free stream on the tip. For the 3 hole configuration, 3 holes spaced 3 hole diameters apart with length to diameter ratio of 1.5 were used. A simulation including 11 holes along the entire mean camber line is also presented (30 deg toward suction side). In addition, the effect of a single hole is also compared to a flat tip with no injection. The results provide insight into tip flow control methods and can be used to guide further investigation into tip flow control. As noted in past research it is concluded that reducing leakage flow is not necessarily synonymous with reducing losses due to leakage.

  19. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  20. The Effect of Internal Leakages on Thermal Performance in NPPs

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Kim, Doo Won; Jang, Seok Bo

    2007-01-01

    Since the Balance Of Plant (BOP, limited to a turbine cycle in this study) does not contain radioactive material, regulatory authorities did not need to have concerns on it. As the interests on safety and performance is getting more serious and extensive, controlling the level of safety and performance of a BOP have just begun or is about to begin. The performance standards or ageing management programs of the major equipment in a BOP is being developed. The regulatory requirements for tests and/or maintenance are being actively built up. There is also a probabilistic approach quantifying performance of a BOP. The study on quantifying the rate of unanticipated shutdowns caused by careless maintenance and/or tests conducted in a BOP is going on. In this study, the modeling of the entire BOP and the methodologies of thermal performance analysis should be one of the must-have items as well. This study was achieved to ensure fundamental skills related to 1) the detailed steady-state modeling of a BOP and 2) thermal performance analysis under various conditions. Particularly, the paper will focus on the effect of internal leakages inside the valves and FeedWater Heaters (FWHs). The internal leakage is regarded as the flow movement through the isolated path but remaining inside the system boundary of a BOP. For instance, the leakage from one side of a valve seat to the other side, or the leakage through the cracked tubes or tube-sheets in a heat exchanger correspond to internal leakages. We made a BOP model of OPR1000 and investigated thermal performance under the internal leakage in Turbine Bypass Condenser Dump Valves (TBCDV) and FWHs

  1. Marginal Leakage of Class V Composite Resin Restorations

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2018-01-01

    Full Text Available >Introduction: Marginal leakage is one of the significant causes of restoration failure. This in-vitro study was conducted to compare cone beam computed tomography (CBCT and dye-penetration methods for determining marginal leakage at gingival surface of class V resin composite restorations.Materials and Methods: Class V cavities were prepared on the buccal surfaces of nineteen caries-free extracted human molar teeth. Cavities were conditioned and filled. The teeth were immersed in a 50% w/w aqueous silver nitrate solution for 24 h and were taken out and rinsed with distilled water. Then, they were put into a developing solution. Whole specimens were first viewed with CBCT and were then sectioned and evaluated by stereomicroscope.Results: Measurement of agreement between CBCT and stereomicroscope revealed that 15 (78.9% teeth had score 0, 1 (5.3% tooth had score 1, and 1 (5.3% tooth had score 2 in both techniques. Measurement of agreement between CBCT and stereomicroscope techniques, in the detection of marginal leakage, was 89.5% (Kappa coefficient = 0.627, P = 0.00. The Wilcoxon paired rank test revealed no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin (P = 0.157.Conclusion: Considering the limitations of the study, there was no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin of class V composite restorations. CBCT can be used noninvasively to detect the marginal leakage of gingival wall of class V composite restorations using aqueous silver nitrate solution as a tracer.

  2. Root cause evaluation of pressurizer relief valve leakage

    International Nuclear Information System (INIS)

    Olson, D.E.; Voll, B.J.

    1996-01-01

    Pressurizer relief valves at two pressurized water reactor units experienced unacceptable leakage during plant heatup. The leakage was suspected to be caused by excessive pipe loads on the valves. This paper describes how monitoring via hard-wired transducers and a digital data acquisition system was used to quantify the pipe loads on the valves, and assist in determining the root cause of the pipe loads and appropriate corrective actions. The selection of the parameters monitored, how the monitoring was accomplished and interpretation of the results is discussed. The corrective actions implemented based on the monitoring results are also discussed

  3. Leakage radiation spectroscopy of organic/dielectric/metal systems

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Kawalec, Tomasz; Kostiučenko, Oksana

    2014-01-01

    side of a hemisphere fused silica prism with an index matching liquid was illuminated under normal incidence by a He-Cd 325 nm laser. Two orthogonal linear polarizations were used both parallel and perpendicular to the detection plane. Spectrally resolved leakage radiation was observed on the opposite......Leakage radiation spectroscopy of organic para-Hexaphenylene (p-6P) molecules has been performed in the spectral range 420-675 nm which overlaps with the p-6P photoluminescence band. The p-6P was deposited on 40 nm silver (Ag) films on BK7 glass, covered with SiO2 layers. The SiO2 layer thickness...

  4. Method for detecting resin leakage in LWR coolant

    International Nuclear Information System (INIS)

    Girard, J.E.

    1988-05-01

    Resin leakage from condensate polishing units can result in steam generator corrosion. This report describes the development of a resin leakage detection method based in analyzing the organic breakdown products released from resin on heating. The breakdown products are analyzed using high performance liquid chromatography (HPLC) with fluorescence detection. Some of the organic products formed have been identified. A design for a resin monitoring unit, suitable for incorporation into the IONTRAC system, is presented. Theoretically, detection of ppB levels of resin by processing about one liter of water, is possible

  5. Carbon leakage revisited. Unilateral climate policy under directed technical change

    International Nuclear Information System (INIS)

    Maria, Corrado Di; Van derWerf, E.

    2005-01-01

    This paper analyzes the consequences of unilateral climate policy in the presence of directed technical change. We develop a dynamic two-country model in which two otherwise identical countries differ in their environmental policy: one of the countries enforces a (binding) cap on emissions while the other does not. Focusing on carbon leakage, we show how, compared with a 'traditional' endogenous growth model, directed technical change will always lead to lower emissions in the unconstrained country. When clean and dirty goods are good substitutes, it may even be induced to reduce its emissions below the optimum level when both countries are unconstrained, so leakage is negative

  6. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  7. Drain Insertion in Chronic Subdural Hematoma: An International Survey of Practice.

    Science.gov (United States)

    Soleman, Jehuda; Kamenova, Maria; Lutz, Katharina; Guzman, Raphael; Fandino, Javier; Mariani, Luigi

    2017-08-01

    To investigate whether, after the publication of grade I evidence that it reduces recurrence rates, the practice of drain insertion after burr-hole drainage of chronic subdural hematoma has changed. Further, we aimed to document various practice modalities concerning the insertion of a drain adopted by neurosurgeons internationally. We administered a survey to neurosurgeons worldwide with questions relating to the surgical treatment of chronic subdural hematoma, with an emphasis on their practices concerning the use of a drain. The preferred surgical technique was burr-hole drainage (89%). Most surgeons prefer to place a drain (80%), whereas in 56% of the cases the reason for not placing a drain was brain expansion after evacuation. Subdural drains are placed by 50% and subperiosteal drains by 27% of the responders, whereas 23% place primarily a subdural drain if possible and otherwise a subperiosteal drain. Three quarters of the responders leave the drain for 48 hours and give prophylactic antibiotic treatment, mostly a single-shot dose intraoperatively (70%). Routine postoperative computed tomography is done by 59% mostly within 24-48 hours after surgery (94%). Adjunct treatment to surgery rarely is used (4%). The publication of grade I evidence in favor of drain use influenced positively this practice worldwide. Some surgeons are still reluctant to insert a drain, especially when the subdural space is narrow after drainage of the hematoma. The insertion of a subperiosteal drain could be a good alternative solution. However, its outcome and efficacy must be evaluated in larger studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Estimating drain flow from measured water table depth in layered soils under free and controlled drainage

    Science.gov (United States)

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-01-01

    Long records of continuous drain flow are important for quantifying annual and seasonal changes in the subsurface drainage flow from drained agricultural land. Missing data due to equipment malfunction and other challenges have limited conclusions that can be made about annual flow and thus nutrient loads from field studies, including assessments of the effect of controlled drainage. Water table depth data may be available during gaps in flow data, providing a basis for filling missing drain flow data; therefore, the overall goal of this study was to examine the potential to estimate drain flow using water table observations. The objectives were to evaluate how the shape of the relationship between drain flow and water table height above drain varies depending on the soil hydraulic conductivity profile, to quantify how well the Hooghoudt equation represented the water table-drain flow relationship in five years of measured data at the Davis Purdue Agricultural Center (DPAC), and to determine the impact of controlled drainage on drain flow using the filled dataset. The shape of the drain flow-water table height relationship was found to depend on the selected hydraulic conductivity profile. Estimated drain flow using the Hooghoudt equation with measured water table height for both free draining and controlled periods compared well to observed flow with Nash-Sutcliffe Efficiency values above 0.7 and 0.8 for calibration and validation periods, respectively. Using this method, together with linear regression for the remaining gaps, a long-term drain flow record for a controlled drainage experiment at the DPAC was used to evaluate the impacts of controlled drainage on drain flow. In the controlled drainage sites, annual flow was 14-49% lower than free drainage.

  9. Conceptual Design of Liquid Sodium Charging and Draining System of STELLA-2

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Nam, Ho-Yun; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Eoh, Jeahyuk; Yoon, Jung; Kim, Hyungmo; Lee, Hyeong-Yeon; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    STELLA program consist of two phases. In the first phase of the program, separated effects tests for demonstrating the thermal-hydraulic performances of major components such as a decay heat exchanger (DHX), Natural-draft sodium-to-air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS) had been successfully performed using STELLA-1 in 2015. Now is the time for us to proceed to the second phase of STELLA program. In the second phase, to demonstrate thermal-hydraulic performances and safety features and to produce base data for the specific design approval for the PGSFR (Prototype Generation IV Sodium-cooled Fast Reactor) which will be constructed by 2028 in Korea, integral effects tests will be carried out using the STELLA-2 test facility which is underway with detailed design and will be constructed in 2018. To establish the maintenance easiness of test facility and to prevent a de-functionalization of elementary sodium component located under the main experimental sodium loops, arrangement area was separated the sodium charging and draining piping area from main system experimental piping area. The operation margin of test facility and the best use of electro-magnetic pumps were established according to employ connecting line between RV charging piping and main experimental system charging piping. To prevent liquid sodium inflow into the piping of gas supply system, the overflow line was employed in sodium expansion tanks of PHDRS and ADHRS, RV, and reservoirs of IHTS.

  10. Conceptual Design of Liquid Sodium Charging and Draining System of STELLA-2

    International Nuclear Information System (INIS)

    Cho, Chungho; Nam, Ho-Yun; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Eoh, Jeahyuk; Yoon, Jung; Kim, Hyungmo; Lee, Hyeong-Yeon; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum

    2016-01-01

    STELLA program consist of two phases. In the first phase of the program, separated effects tests for demonstrating the thermal-hydraulic performances of major components such as a decay heat exchanger (DHX), Natural-draft sodium-to-air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS) had been successfully performed using STELLA-1 in 2015. Now is the time for us to proceed to the second phase of STELLA program. In the second phase, to demonstrate thermal-hydraulic performances and safety features and to produce base data for the specific design approval for the PGSFR (Prototype Generation IV Sodium-cooled Fast Reactor) which will be constructed by 2028 in Korea, integral effects tests will be carried out using the STELLA-2 test facility which is underway with detailed design and will be constructed in 2018. To establish the maintenance easiness of test facility and to prevent a de-functionalization of elementary sodium component located under the main experimental sodium loops, arrangement area was separated the sodium charging and draining piping area from main system experimental piping area. The operation margin of test facility and the best use of electro-magnetic pumps were established according to employ connecting line between RV charging piping and main experimental system charging piping. To prevent liquid sodium inflow into the piping of gas supply system, the overflow line was employed in sodium expansion tanks of PHDRS and ADHRS, RV, and reservoirs of IHTS

  11. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  12. Brain drain and health workforce distortions in Mozambique.

    Science.gov (United States)

    Sherr, Kenneth; Mussa, Antonio; Chilundo, Baltazar; Gimbel, Sarah; Pfeiffer, James; Hagopian, Amy; Gloyd, Stephen

    2012-01-01

    Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs), and the private sector. An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties. Of 723 qualifying physicians between 1980-2006, 95.9% (693) were working full-time, including 71.1% (493) as clinicians, 20.5% (142) as health system managers, and 6.9% (48) as researchers/professors. 25.5% (181) of the sample had left the public sector, of which 62.4% (113) continued working in-country and 37.6% (68) emigrated from Mozambique. Of those cases of internal migration, 66.4% (75) worked for NGOs, 21.2% (24) for donor agencies, and 12.4% (14) in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113) of internal migration cases had previously held senior-level management positions in the public sector. Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they seek

  13. Greenhouse gases emission from the sewage draining rivers.

    Science.gov (United States)

    Hu, Beibei; Wang, Dongqi; Zhou, Jun; Meng, Weiqing; Li, Chongwei; Sun, Zongbin; Guo, Xin; Wang, Zhongliang

    2018-01-15

    Carbon dioxide (CO 2 ), methane (CH 4 ) and nitrous oxide (N 2 O) concentration, saturation and fluxes in rivers (Beitang drainage river, Dagu drainage rive, Duliujianhe river, Yongdingxinhe river and Nanyunhe river) of Tianjin city (Haihe watershed) were investigated during July and October in 2014, and January and April in 2015 by static headspace gas chromatography method and the two-layer model of diffusive gas exchange. The influence of environmental variables on greenhouse gases (GHGs) concentration under the disturbance of anthropogenic activities was discussed by Spearman correlative analysis and multiple stepwise regression analysis. The results showed that the concentration and fluxes of CO 2 , CH 4 and N 2 O were seasonally variable with >winter>fall>summer, spring>summer>winter>fall and summer>spring>winter>fall for concentrations and spring>summer>fall>winter, spring>summer>winter>fall and summer>spring>fall>winter for fluxes respectively. The GHGs concentration and saturation were higher in comprehensively polluted river sites and lower in lightly polluted river sites. The three GHGs emission fluxes in two sewage draining rivers of Tianjin were clearly higher than those of other rivers (natural rivers) and the spatial variation of CH 4 was more obvious than the others. CO 2 and N 2 O air-water interface emission fluxes of the sewage draining rivers in four seasons were about 1.20-2.41 times and 1.13-3.12 times of those in the natural rivers. The CH 4 emission fluxes of the sewage draining rivers were 3.09 times in fall to 10.87 times in spring of those in the natural rivers in different season. The wind speed, water temperature and air temperature were related to GHGs concentrations. Nitrate and nitrite (NO 3 - +NO 2 - -N) and ammonia (NH 4 + -N) were positively correlated with CO 2 concentration and CH 4 concentration; and dissolved oxygen (DO) concentration was negatively correlated with CH 4 concentration and N 2 O concentration. The effect of

  14. Brain drain and health workforce distortions in Mozambique.

    Directory of Open Access Journals (Sweden)

    Kenneth Sherr

    Full Text Available Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs, and the private sector.An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties.Of 723 qualifying physicians between 1980-2006, 95.9% (693 were working full-time, including 71.1% (493 as clinicians, 20.5% (142 as health system managers, and 6.9% (48 as researchers/professors. 25.5% (181 of the sample had left the public sector, of which 62.4% (113 continued working in-country and 37.6% (68 emigrated from Mozambique. Of those cases of internal migration, 66.4% (75 worked for NGOs, 21.2% (24 for donor agencies, and 12.4% (14 in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113 of internal migration cases had previously held senior-level management positions in the public sector.Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they

  15. 75 FR 29699 - Total Inward Leakage Requirements for Respirators

    Science.gov (United States)

    2010-05-27

    ... or other half-mask respirator inward leakage measurement, and offer any additional comments on the..., facsimile (412) 386-4089, e-mail [email protected] . SUPPLEMENTARY INFORMATION: I. Background The Department of... order to conduct tests and prepare responses. On April 20, 2010, NIOSH responded by reopening the docket...

  16. University student's education after Fukushima nuclear leakage crisis

    International Nuclear Information System (INIS)

    Dou Daying; Gu Jianzhong; Zheng Jianying

    2012-01-01

    Fukushima nuclear leakage crisis after 3.11 earthquake and tsunami, the horrible INES-7 accident warns the colleagues all over the world. Own much to the experts' reports on public media, INES classification, basic knowledge of nuclear reactor, nuclear safety and protection had been discussed and brain-stormed in detail. (authors)

  17. Leakage monitoring equipment of fuel element by delayed neutron method

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Shulan; Zhang Shuheng

    1999-01-01

    Based on monitoring results of delayed neutrons from reactor first circle water, the leakage of reactor fuel elements is monitored. A monitoring equipment consisted of an array of 3 He proportional counter tubes with 75 s delay has been developed. The neutron detection efficiency of 6.1% is obtained

  18. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    driniev

    Abstract. A project to assess the levels of leakage in 30 water utilities throughout South Africa was initiated by the Water ... average operating pressure, systems input volume and the compo- ... simple, user-friendly model that is based on an excel spreadsheet ..... One can see from the four graphs presented here that various.

  19. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  20. Reaction-driven casing expansion : potential for wellbore leakage mitigation

    NARCIS (Netherlands)

    Wolterbeek, Timotheus K. T.; van Noort, Reinier; Spiers, Christopher J.

    It is generally challenging to predict the post-abandonment behaviour and integrity of wellbores. Leakage is, moreover, difficult to mitigate, particularly between the steel casing and outer cement sheath. Radially expanding the casing with some form of internal plug, thereby closing annular voids

  1. Carbon Leakage Revisited : Unilateral Climate Policy with Directed Technical Change

    NARCIS (Netherlands)

    Di Maria, C.; van der Werf, E.H.

    2005-01-01

    The increase in carbondioxide emissions by some countries in reaction to an emission reduction by countries with climate policy (carbon leakage) is seen as a serious threat to unilateral climate policy.Using a two-country model where only one of the countries enforces an exogenous cap on emissions,

  2. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Science.gov (United States)

    2010-10-01

    ... following minimum requirements: (1) A leakage survey with leak detector equipment must be conducted in business districts, including tests of the atmosphere in gas, electric, telephone, sewer, and water system... survey with leak detector equipment must be conducted outside business districts as frequently as...

  3. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  4. Superconducting coil configurations, with low flux leakage, for energy storage

    International Nuclear Information System (INIS)

    Vincent-Viry, O.; Mailfert, A.; Trassart, D.

    2001-01-01

    This paper presents two original types of SMES structures for energy storage. These two groups of SMES structures proceeded from an ideal structure: the full toroid, are modeled by the use of purely surface current densities. Their main advantage is to present no flux leakage, they give then satisfactory solution to the problem of energy storage. (orig.)

  5. Optimized quantization in Zero Leakage Helper data systems

    NARCIS (Netherlands)

    Stanko, T.; Andini, F.N.; Skoric, B.

    2017-01-01

    Helper data systems are a cryptographic primitive that allows for the reproducible extraction of secrets from noisy measurements. Redundancy data called helper data makes it possible to do error correction while leaking little or nothing (Zero Leakage) about the extracted secret string. We study the

  6. Modelling of heterogenous neutron leakages in a nuclear reactor

    International Nuclear Information System (INIS)

    Wohleber, X.

    1997-01-01

    The TIBERE Model is a neutron leakage method based on B 1 heterogeneous transport equation resolution. In this work, we have studied the influence of the reflection mode at the boundary of the assembly. In particular the White boundary condition has been implemented in the APOLLO2 neutron transport code. We have compared the two TIBERE kinds of boundary conditions (specular and white) with the classical B 1 homogeneous leakage method in the modelling of some reactors. We have remarked the better capability of the TIBERE Model to compute voided assemblies. The white boundary condition is also able to compute a completely voided assembly and, besides, wins a factor 10 in CPU time in comparison with the specular boundary condition. These two heterogenous leakage formalisms have been tested on a partially voided experiment and have shown that the TIBERE Model can compute this kind of situation with a greater precision than the classical B 1 homogeneous leakage method, and with a shorter computational time. (author)

  7. Exploitation of Unintentional Information Leakage from Integrated Circuits

    Science.gov (United States)

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  8. Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram

    Science.gov (United States)

    Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.

    2015-10-01

    Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  9. Leakage detection in underground gas mains with radioaktive argon

    International Nuclear Information System (INIS)

    Schmitz, J.

    1975-01-01

    In the field of gas supply, radionuclide techniques are suitable for the routine monitoring of transport mains by means of highly active tracer clouds and a measuring scraper as well as for exact leakage detection in local gas distribution systems. Very good results are obtained in the case of mains lying lower than 1.5 m if the length and alignment of the pipe section allow a towing probe to be pulled through. This was investigated systematically on a model stretch under practical conditions. The attempts to detect leakages were made with the aid of the radioactive isotope 41 Ar. Under conditions close to practice concerning pipe bedding, branching, pre-pressure, and leakage diameter, a leak with leakage rates as small as approx. 1 l/min could be measured with the aid of a towing probe with a precision of +-0.5 m. This accuracy is another advantage of this method. Branching and fittings with a big dead volume do not interfere with the evaluation. The investment for this method can be compared to other physical/technical investigations on mains, e.g. weld seam tests. (orig./LN) [de

  10. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  11. Colorectal anastomotic leakage: Aspects of prevention, detection and treatment

    NARCIS (Netherlands)

    F. Daams (Freek); M. Luyer (Misha); J.F. Lange (Johan)

    2013-01-01

    textabstractAll colorectal surgeons are faced from time to time with anastomotic leakage after colorectal surgery. This complication has been studied extensively without a significant reduction of incidence over the last 30 years. New techniques of prevention, by innovative anastomotic techniques

  12. First principle leakage current reduction technique for CMOS devices

    CSIR Research Space (South Africa)

    Tsague, HD

    2015-12-01

    Full Text Available This paper presents a comprehensive study of leakage reduction techniques applicable to CMOS based devices. In the process, mathematical equations that model the power-performance trade-offs in CMOS logic circuits are presented. From those equations...

  13. Incidence and management of chyle leakage after esophagectomy

    NARCIS (Netherlands)

    Lagarde, Sjoerd M.; Omloo, Jikke M. T.; de Jong, Koen; Busch, Olivier R. C.; Obertop, Hugo; van Lanschot, J. Jan B.

    2005-01-01

    BACKGROUND: Postoperative chyle leakage is a rare but well-recognized complication after esophageal surgery. The aim of this study was to identify its incidence and potentially predisposing factors and to assess the consequences and management. METHODS: A consecutive series of 536 patients who

  14. Characterization of CO2 leakage into the freshwater body

    DEFF Research Database (Denmark)

    Singh, Ashok; Delfs, Jens Olaf; Shao, H.

    2013-01-01

    urrent research into CO2 capture and storage is dominated by improving the CO2 storage capacity. In this context, risk related to CO2 leakage is an important issue which may cause environmental problems, particularly when freshwater resources nearby are intruded by the CO2 plume. In this work...

  15. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  16. The Effect of Coriolis Force on the Formation of Dip on the Free Surface of Water Draining from a Tank

    International Nuclear Information System (INIS)

    Jo, Jong Chull; Kang, Dong Gu; Kim, Hho Jhung; Roh, Kyung Wan; Yune, Young Gill

    2007-01-01

    For the case of RWT (refueling water tank) connecting to the ECC (emergency core cooling) line, it can be surmised that there is a possibility of ECC pump failure due to air ingression into the ECC supply line even before the RWT is drained away. Therefore, it is important to check if the operational limit of the RWT water level is set at a value higher than the critical height that causes a dip formation on the free surface of a draining liquid. In the previous work, such complex unsteady flow fields both in a simple water tank and in the RWT at the Korean standard nuclear power plant have been simulated using the CFX5.10 code which is well-known as one of the well-validated commercial CFD (Computational Fluid Dynamics) codes. However, for the simplicity of those calculations the Coriolis force has not been taken into account. Thus, in the present paper, the effect of Coriolis force-induced vortex flow on the dip formation of dip has been investigated for the simple water tank to confirm validity of the previous work. To do this the unsteady flow fields accompanied by vortex in the simple water tank has been simulated using the CFX5.10 code

  17. The Effect of Coriolis Force on the Formation of Dip on the Free Surface of Water Draining from a Tank

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jong Chull; Kang, Dong Gu; Kim, Hho Jhung; Roh, Kyung Wan; Yune, Young Gill [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2007-10-15

    For the case of RWT (refueling water tank) connecting to the ECC (emergency core cooling) line, it can be surmised that there is a possibility of ECC pump failure due to air ingression into the ECC supply line even before the RWT is drained away. Therefore, it is important to check if the operational limit of the RWT water level is set at a value higher than the critical height that causes a dip formation on the free surface of a draining liquid. In the previous work, such complex unsteady flow fields both in a simple water tank and in the RWT at the Korean standard nuclear power plant have been simulated using the CFX5.10 code which is well-known as one of the well-validated commercial CFD (Computational Fluid Dynamics) codes. However, for the simplicity of those calculations the Coriolis force has not been taken into account. Thus, in the present paper, the effect of Coriolis force-induced vortex flow on the dip formation of dip has been investigated for the simple water tank to confirm validity of the previous work. To do this the unsteady flow fields accompanied by vortex in the simple water tank has been simulated using the CFX5.10 code.

  18. Effect of an intervention in storm drains to prevent Aedes aegypti reproduction in Salvador, Brazil.

    Science.gov (United States)

    Souza, Raquel Lima; Mugabe, Vánio André; Paploski, Igor Adolfo Dexheimer; Rodrigues, Moreno S; Moreira, Patrícia Sousa Dos Santos; Nascimento, Leile Camila Jacob; Roundy, Christopher Michael; Weaver, Scott C; Reis, Mitermayer Galvão; Kitron, Uriel; Ribeiro, Guilherme Sousa

    2017-07-11

    Aedes aegypti, the principal vector for dengue, chikungunya and Zika viruses, is a synanthropic species that uses stagnant water to complete its reproductive cycle. In urban settings, rainfall water draining structures, such as storm drains, may retain water and serve as a larval development site for Aedes spp. reproduction. Herein, we describe the effect of a community-based intervention on preventing standing water accumulation in storm drains and their consequent infestation by adult and immature Ae. aegypti and other mosquitoes. Between April and May of 2016, local residents association of Salvador, Brazil, after being informed of water accumulation and Ae. aegypti infestation in the storm drains in their area, performed an intervention on 52 storm drains. The intervention consisted of placing concrete at the bottom of the storm drains to elevate their base to the level of the outflow tube, avoiding water accumulation, and placement of a metal mesh covering the outflow tube to avoid its clogging with debris. To determine the impact of the intervention, we compared the frequency at which the 52 storm drains contained water, as well as adult and immature mosquitoes using data from two surveys performed before and two surveys performed after the intervention. During the pre-intervention period, water accumulated in 48 (92.3%) of the storm drains, and immature Ae. aegypti were found in 11 (21.2%) and adults in 10 (19.2%). After the intervention, water accumulated in 5 (9.6%) of the storm drains (P Aedes mosquitoes (mainly Culex spp.) in the storm drains also decreased after the intervention. This study exemplifies how a simple intervention targeting storm drains can result in a major reduction of water retention, and, consequently, impact Ae. aegypti larval populations. Larger and multi-center evaluations are needed to confirm the potential of citywide structural modifications of storm drains to reduce Aedes spp. infestation level.

  19. Pesticide transport to tile-drained fields in SWAT model – macropore flow and sediment

    DEFF Research Database (Denmark)

    Lu, Shenglan; Trolle, Dennis; Blicher-Mathiesen, Gitte

    2015-01-01

    Tool (SWAT) to simulate transport of both mobile (e.g. Bentazon) and strongly sorbed (e.g. Diuron) pesticides in tile drains. Macropore flow is initiated when soil water content exceeds a threshold and rainfall intensity exceeds infiltration capacity. The amount of macropore flow is calculated...... to macropore sediment transport. Simulated tile drain discharge, sediment and pesticide loads are calibrated against data from intensively monitored tile-drained fields and streams in Denmark....

  20. Brain drain in globalization A general equilibrium analysis from the sending countries’ perspective

    OpenAIRE

    Luca MARCHIORI; I-Ling SHEN; Frederic DOCQUIER

    2009-01-01

    The paper assesses the global effects of brain drain on developing economies and quantifies the relative sizes of various static and dynamic impacts. By constructing a unified generic framework characterized by overlapping generations dynamics and calibrated to real data, this study incorporates many direct impacts of brain drain whose interactions, along with other indirect effects, are endogenously and dynamically generated. Our findings suggest that the short-run impact of brain drain on r...

  1. Factors related to ostomy leakage in the community setting.

    Science.gov (United States)

    Ratliff, Catherine R

    2014-01-01

    The purpose of this study was to describe demographic and clinical variables related to ostomy pouch leakage from those discharged from a major medical center during a 2-year period. A convenience sample of 198 persons with an ostomy was obtained using the ICD-9 (International Classification of Diseases, Ninth Revision) codes for colostomy, ileostomy, and ileal conduit for patients who were discharged from the medical center within the time frame of July 2009 to July 2011. One hundred seven participants (55%) returned a completed survey. Respondents included 57 men (53%) and 50 women (47%). The mean age was 60 years with age range from 23 to 91 years. Fecal ostomies made up the majority of the stomas representing 71 patients (66%). A descriptive, cross-sectional research design was used to describe clinical variables related to ostomy pouch leakage for those discharged from a major academic medical center over a 2-year period of time. Participants were mailed an introductory letter from the principal investigator, a self-administered questionnaire, and a prepaid return envelope. Ninety-three patients (87%) reported leakage; however, 48 patients (45%) stated that they did not leak often. A logistic regression was estimated to determine which variables were significant predictors of the dependent variable of leaking status (no/seldom leaking vs more frequent leaking). Two variables were individually significant predictors, sex (P = .021) and 2-piece pouch (P = .015). Women were 4 times more likely to be in the more frequent leaking group than were men. Those who were wearing 2-piece pouches were 78% less likely to be in the more frequent leaking group. Participants with ileostomies or urostomies were more likely to be in the more frequent leaking group and those with peristomal skin irritation were more likely to be in the more frequent leaking group. Findings from this study reveal that women were more likely to experience leakage than men and that wearing a 2-piece

  2. Brain drain: a challenge to global mental health.

    Science.gov (United States)

    Oladeji, Bibilola D; Gureje, Oye

    2016-08-01

    The brain drain of medical professionals from lower-income to higher-income countries contributes to the current inequity that characterises access to mental healthcare by those in need across the world and hinders efforts to scale up mental health services in resource-constrained settings, especially in Nigeria and other West African countries. The migration of skilled workers is driven by a combination of the globalisation of the labour market and the ability of highly resourced countries to attract and retain specialists from poorer countries. If we are to ameliorate the worldwide shortage of mental health professionals, we need to find innovative ways of attracting young doctors into psychiatric training in all countries. We must also introduce measures to improve health worker retention in low- and middle-income countries.

  3. Reducing resin use in floor drain processing system

    International Nuclear Information System (INIS)

    Flint, W.; Hobart, S.A.; Miller, A.D.

    1995-01-01

    The Kewaunee Nuclear Power Plant utilizes two mixed bed demineralizers for processing floor drain wastes. These demineralizers were originally designed for stream generator blowdown treatment, but were not needed for that purpose. Effluent from the resin beds is monitored for radioactivity and released for discharge. Plant radwaste inleakage volumes and resin disposal volumes were low in comparison with industry averages, but decontamination factors through the treatment system were less than desirable. Release criteria for discharges always had been met, but plant personnel wished to decrease their already low discharges of radioactive species, reduce their resin disposal costs, and provide a margin of safety in the unlikely event that fuel damage would be experienced during an operating cycle. This paper describes the study initiated to address those issues, the findings of the study, and results of implementing some of the study recommendations

  4. Nuclear power plant laundry drain treatment using membrane bio reactor

    International Nuclear Information System (INIS)

    Tsukamoto, Masaaki; Kohanawa, Osamu; Kinugasa, Atsushi; Ogawa, Naoki; Murogaki, Kenta

    2012-01-01

    In nuclear power plant, the radioactive effluent generated by washing the clothes worn in controlled area and the hand and shower water used at the controlled area are treated in laundry drain treatment system. Although various systems which treat such liquid waste preexist, the traditional treatment system has disadvantages such as high running cost and a large amount of secondary waste generation. To solve these matters, we have considered application of an activated sludge system, membrane bio reactor, which has been practically used in general industry. For nuclear power plant, the activated sludge system has been developed, tested in its adaptability and the adequacy has been proved. Some preexisting treatment systems have been replaced with this activated sludge system for the first time in a domestic nuclear power plant, and the renewal system is now in operation. The result is reported. (author)

  5. Centrifuge modelling of drained lateral pile - soil response

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte

    of rigid piles. The tests have been performed in homogeneously dense dry or saturated Fontainebleau sand in order to mimic simplified drained offshore soil conditions. Approximately half of the tests have been carried out to investigate the centrifuge procedure in order to create a methodology of testing...... tests were used to investigate the pile - soil interaction to gain a better in-sight into the complex problem. A monotonic test series was carried out initially and then pile - soil interaction curves were deduced from these tests and compared with methodologies used today. The results indicate...... that the current methodologies can be improved and a modification to the methodology has been proposed. Secondly, a cyclic test series was carried out. The accumulation of displacement and the change in secant stiffness of the total response of these tests were evaluated. A simple mathematical model was proposed...

  6. Understanding and managing leakage in forest-based greenhouse-gas-mitigation projects.

    Science.gov (United States)

    Schwarze, Reimund; Niles, John O; Olander, Jacob

    2002-08-15

    A major concern about land use, land-use change and forestry (LULUCF) projects under the Clean Development Mechanism (CDM) is the potential for leakage. Leakage refers to a net increase of greenhouse-gas emissions in an area outside the project resulting from the CDM activity. This paper provides an overview of leakage, its definitions and its causes. It describes ways that LULUCF projects may suffer from leakage and attempts to assess the magnitude of leakage risks for different LULUCF project types. It also summarizes some of the approaches, both in terms of policies and project development, to address LULUCF leakage.

  7. CSER 94-011: Use of glovebags for demister draining operations

    International Nuclear Information System (INIS)

    Hess, A.L.

    1994-01-01

    A criticality safety review is presented for the use of plastic-sheet glovebags for the operations of draining demisters on the 26-inch vacuum system headers. A criticality drain is required because of the possibility for spilling liquid of sufficient volume and fissile content for criticality. It is recommended that the glovebag design include a rigid, 2ft x 2ft floor with a central drain feeding a geometrically favorable spill-catch vessel, plus a screen grid above the bottom for drain protection

  8. Method of draining water through a solid waste site without leaching

    Science.gov (United States)

    Treat, Russell L.; Gee, Glendon W.; Whyatt, Greg A.

    1993-01-01

    The present invention is a method of preventing water from leaching solid waste sites by preventing atmospheric precipitation from contacting waste as the water flows through a solid waste site. The method comprises placing at least one drain hole through the solid waste site. The drain hole is seated to prevent waste material from entering the drain hole, and the solid waste site cover material is layered and graded to direct water to flow toward the drain hole and to soil beneath the waste site.

  9. Estimation of local and regional components of drain - flow from an irrigated field

    International Nuclear Information System (INIS)

    Eching, S.O.; Hopmans, J.W.; Wallender, W.W.; Macyntyre, J.L.; Peters, D.

    1995-01-01

    The contribution of regional ground water and deep percolation from a furrow irrigated field to total drain flow was estimated using salt load analysis. It was found that 64% of the drain flow comes from regional ground water flow. The electrical conductivity of the drain water was highly correlated with the drain flow rate. From the field water balance with deep percolation as estimated from the salt load analysis, using yield function derived evapotranspiration, and measured changes in root zone water storage, it was shown that 14% of the crop evapotranspiration comes from ground water during the study period. 8 figs; 5 tabs; 15 refs ( Author )

  10. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario.

    Science.gov (United States)

    Ma, Jing; Zhang, Wangyuan; Zhang, Shaoliang; Zhu, Qianlin; Feng, Qiyan; Chen, Fu

    2017-01-01

    The technology of carbon dioxide (CO 2 ) capture and storage (CCS) has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO 2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO 2 geological storage was designed to investigate the short-term effects of different CO 2 leakage concentration (from 400 g m -2 day -1 to 2,000 g m -2 day -1 ) on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO 2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO 2 concentrations. Increasing CO 2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 ( p soil CO 2 concentration increased. The dominant phylum in the soil samples was Proteobacteria , whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% ( p soil ecosystems.

  11. Radiation leakage dose from Elekta electron collimation system.

    Science.gov (United States)

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  12. Low-leakage-current AlGaN/GaN HEMTs on Si substrates with partially Mg-doped GaN buffer layer by metal organic chemical vapor deposition

    International Nuclear Information System (INIS)

    Li Ming; Wang Yong; Wong Kai-Ming; Lau Kei-May

    2014-01-01

    High-performance low-leakage-current AlGaN/GaN high electron mobility transistors (HEMTs) on silicon (111) substrates grown by metal organic chemical vapor deposition (MOCVD) with a novel partially Magnesium (Mg)-doped GaN buffer scheme have been fabricated successfully. The growth and DC results were compared between Mg-doped GaN buffer layer and a unintentionally one. A 1-μm gate-length transistor with Mg-doped buffer layer exhibited an OFF-state drain leakage current of 8.3 × 10 −8 A/mm, to our best knowledge, which is the lowest value reported for MOCVD-grown AlGaN/GaN HEMTs on Si featuring the same dimension and structure. The RF characteristics of 0.25-μm gate length T-shaped gate HEMTs were also investigated

  13. GaN-on-silicon high-electron-mobility transistor technology with ultra-low leakage up to 3000 V using local substrate removal and AlN ultra-wide bandgap

    Science.gov (United States)

    Dogmus, Ezgi; Zegaoui, Malek; Medjdoub, Farid

    2018-03-01

    We report on extremely low off-state leakage current in AlGaN/GaN-on-silicon metal–insulator–semiconductor high-electron-mobility transistors (MISHEMTs) up to a high blocking voltage. Remarkably low off-state gate and drain leakage currents below 1 µA/mm up to 3 kV have been achieved owing to the use of a thick in situ SiN gate dielectric under the gate, and a local Si substrate removal technique combined with a cost effective 15-µm-thick AlN dielectric layer followed by a Cu deposition. This result establishes a manufacturable state-of-the-art high-voltage GaN-on-silicon power transistors while maintaining a low specific on-resistance of approximately 10 mΩ·cm2.

  14. Perioperative Statin Therapy Is Not Associated With Reduced Risk of Anastomotic Leakage After Colorectal Resection

    DEFF Research Database (Denmark)

    Bisgård, Anne Sofie; Noack, Morten Westergaard; Klein, Mads

    2013-01-01

    Anastomotic leakage is a serious complication of colorectal surgery. Several studies have demonstrated the beneficial pleiotropic effects of statins, and preliminary studies have suggested that perioperative statin treatment may be associated with reduced risk of anastomotic leakage....

  15. Liquefaction under drained condition, from the lab to reality ?

    Science.gov (United States)

    Clément, Cécile; Aharonov, Einat; Stojanova, Menka; Toussaint, Renaud

    2015-04-01

    Liquefaction constitutes a significant natural hazard in relation to earthquakes and landslides. This effect can cause buildings to tilt or sink into the soil, mud-volcanoes, floatation of buried objects, long-runout landslides, etc. In this work we present a new understanding regarding the mechanism by which buildings sink and tilt during liquefaction caused by earthquakes. Conventional understanding of liquefaction explains most observed cases as occurring in an undrained, under-compacted, layer of sandy soil saturated with water [1]: According to that understanding, the under compacted sandy layer has the tendency to compact when a load is applied. In our case the load comes from ground shaking during an earthquake. When the soil compacts, the fluid pore pressure rises. Because in undrained conditions the fluid cannot flow out, the pore pressure builds up. The weight of buildings is in this case transferred from the grains of the soil to the pore water. The soil loses its rigidity and it flows like a liquid. From this model scientists made theoretical and empirical laws for geotechnical use and buildings construction. Despite the success of this conventional model in many cases, liquefied soils were also observed under drained conditions, and in previously compacted soils, which doesn't agree with the assumption of the model quoted above. One of the famous liquefaction events is the Kobe port destruction during the 1995 earthquake. A simple calculation of the Deborah number following Goren et al ([2][3]) shows that the undrained constraint was not met below the Kobe port during the 1995 earthquake. We propose another model, of liquefaction in drained granular media. According to our model the mere presence of water in granular media is enough to cause liquefaction during an earthquake, provided that the water reaches close to the surface. Our computations are based on the buoyancy force, and we take into account the static fluid pressure only. For small

  16. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events

    OpenAIRE

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while c...

  17. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    OpenAIRE

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was c...

  18. Draining Water from Aircraft Fuel Using Nitrogen Enriched Air

    Directory of Open Access Journals (Sweden)

    Michael Frank

    2018-04-01

    Full Text Available This paper concerns a computational study of the process of removing water from an aircraft’s fuel tank by pumping nitrogen enriched air (NEA from the bottom of the tank. This is an important procedure for the smooth, efficient, and safe operation of the aircraft’s engine. Due to the low partial pressure of water in the pumped NEA, it absorbs water from the fuel. The water-laden bubbles enter the ullage, the empty space above the fuel, and escape into the environment. The effects of the number of NEA inlets and the NEA mass flow rate on the timescale of the NEA pumping were investigated using Computational Fluid Dynamics. The results reveal that the absorption of water by the NEA bubbles is low and is not affected by the number of the inlets used. Yet, the water content in the fuel decreases fast during the procedure, which is the desired outcome. We show that this is due to the relatively dry NEA entering the ullage and displacing the moist air, thus reducing the partial pressure of water at the fuel/ullage interface. This shift from equilibrium conditions forces water to evaporate from the fuel’s entire surface. Furthermore, the amount of water migrating from the fuel directly into the ullage is significantly greater than that absorbed by the rising bubbles. In turn, the rate of decrease of the water content in the ullage is determined by the total NEA mass flow rate and this is the dominant contributor to the draining time, with the number of NEA nozzles playing a minor role. We confirmed this by pumping NEA directly into the ullage, where we observe a significant decrease of water even when the NEA is not pumped through the fuel. We also show that doubling the mass flow rate halves the draining time. When considering the capability of most modern aircraft to pump NEA through the fuel as part of their inerting system, the proposed method for removing water is particularly attractive, requiring very little (if at all design modification.

  19. Filling, storing and draining. Three key aspects of landslide hydrology

    Science.gov (United States)

    Bogaard, Thom; Greco, Roberto

    2016-04-01

    Rainfall-triggered landslides are among the most widespread hazards in the world. The hydrology in and around a landslide area is key to pore pressure build-up in the soil skeleton which reduces shear strength due to the buoyancy force exerted by water in a saturated soil and to soil suction in an unsaturated soil. Extraordinary precipitation events trigger most of the landslides, but, at the same time, the vast majority of slopes do not fail. The intriguing question is: 'When and where exactly can a slope become triggered to slide and flow downwards?' The objective of this article is to present and discuss landslide hydrology at three scales - pore, hillslope, and catchment - which, taken together, give an overview of this interdisciplinary science. In fact, for rainfall-triggered landslides to occur, an unfavourable hydrological interplay should exist between fast and/or prolonged infiltration, and a relatively 'slow' drainage. The competition of water storage, pressure build-up and the subsequently induced drainage contains the importance of the timing, which is indisputably one of the more delicate but relevant aspects of landslide modelling, the overlay of hydrological processes with different time scales. As slopes generally remain stable, we can argue that effective drainage mechanisms spontaneously develop, as the best for a slope to stay stable is getting rid of the overload of water (above field capacity), either vertically or laterally. So, landslide hydrology could be framed as 'Filling-Storing-Draining'. Obviously, 'Storing' is added to stress the importance of dynamic pressure build-up for slope stability. 'Draining' includes all removal of water from the system (vertical and lateral flow, evaporation and transpiration) and thus pore water pressure release. Furthermore, by addressing landslide hydrology from both earth sciences and soil mechanics perspectives, we aim to manifest the hydrological processes in hillslopes and their influence on behaviour

  20. Management of Chest Drains: A National Survey on Surgeons‑in ...

    African Journals Online (AJOL)

    triangle of safety [Figure 1]. Just above a quarter of respondents (27.2%) always utilized different sizes of tubes for different pathologies and the same proportion of respondents always positioned the tip of the tube apically to drain pneumothorax and basally to drain pleural effusion. In contrast, 9.9% and 6.2% of respondents.

  1. Controlling the ambipolarity and improvement of RF performance using Gaussian Drain Doped TFET

    Science.gov (United States)

    Nigam, Kaushal; Gupta, Sarthak; Pandey, Sunil; Kondekar, P. N.; Sharma, Dheeraj

    2018-05-01

    Ambipolar conduction in tunnel field-effect transistors (TFETs) has been occurred as an inherent issue due to drain-channel tunneling. It makes TFET less efficient and restricts its application in complementary digital circuits. Therefore, this manuscript reports the application of Gaussian doping profile on nanometer regime silicon channel TFETs to completely eliminate the ambipolarity. For this, Gaussian doping is used in the drain region of conventional gate-drain overlap TFET to control the tunneling of electrons from the valence band of channel to the conduction band of drain. As a result, barrier width at the drain/channel junction increases significantly leading to the suppression of an ambipolar current even when higher doping concentration (1 ? 10 ? cm ?) is considered in the drain region. However, significant improvement in terms of RF figure-of-merits such as cut-off frequency (f ?), gain bandwidth product (GBW), and gate-to-drain capacitance (C ?) is achieved with Gaussian doped gate on drain overlap TFET as compared to its counterpart TFET.

  2. 77 FR 30886 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Science.gov (United States)

    2012-05-24

    ... interpretation and installed unblockable drain covers and now would have to go back and ``re-do'' their work... compliance and whether the pool operator is seeking a plan review and not just limited advice about how to... secondary anti-entrapment system to come into compliance, unless the pool uses a gravity drain system or the...

  3. Laparoscopic elective cholecystectomy with and without drain: A controlled randomised trial

    Directory of Open Access Journals (Sweden)

    Gouda El-labban

    2012-01-01

    Full Text Available Background : Laparoscopic cholecystectomy is the main method of treatment of symptomatic gallstones. Routine drainage after laparoscopic cholecystectomy is an issue of considerable debate. Therefore, a controlled randomised trial was designed to assess the value of drains in elective laparoscopic cholecystectomy. Materials and Methods: During a two-year period (From April 2008 to January 2010, 80 patients were simply randomised to have a drain placed (group A, an 8-mm pentose tube drain was retained below the liver bed, whereas 80 patients were randomised not to have a drain (group B placed in the subhepatic space. End points of this trial were to detect any differences in morbidity, postoperative pain, wound infection and hospital stay between the two groups. Results : There was no mortality in either group and no statistically significant difference in postoperative pain, nausea and vomiting, wound infection or abdominal collection between the two groups. However, hospital stay was longer in the drain group than in group without drain and it is appearing that the use of drain delays hospital discharge. Conclusion : The routine use of a drain in non-complicated laparoscopic cholecystectomy has nothing to offer; in contrast, it is associated with longer hospital stay.

  4. Nurses’ knowledge of care of chest drain: A survey in a Nigerian semiurban university hospital

    Science.gov (United States)

    Kesieme, Emeka Blessius; Essu, Ifeanyichukwu Stanley; Arekhandia, Bruno Jeneru; Welcker, Katrin; Prisadov, Georgi

    2016-01-01

    Background/Objective: Inefficient nursing care of chest drains may associated with unacceptable and sometimes life-threatening complications. This report aims to ascertain the level of knowledge of care of chest drains among nurses working in wards in a teaching hospital in Nigeria. Methods: A cross-sectional study among nurses at teaching hospital using pretested self-administered questionnaires. Results: The majority were respondents aged between 31 and 40 years (45.4%) and those who have nursing experience between 6 and 10 years. Only 37 respondents (26.2%) had a good knowledge of nursing care of chest drains. Knowledge was relatively higher among nurses who cared for chest drains daily, nurses who have a work experience of 0.05). Performance was poor on the questions on position of drainage system were not statistically significant with relationship to waist level while mobilizing the patient, application of suction to chest drains, daily changing of dressing over chest drain insertion site, milking of tubes and drainage system with dependent loop. Conclusion: The knowledge of care of chest drains among nurses is poor, especially in the key post procedural care. There is an urgent need to train them so as to improve the nursing care of patients managed with chest drains. PMID:26857934

  5. Allocation of emission permits with leakage through capital markets

    International Nuclear Information System (INIS)

    Maestad, Ottar

    2007-01-01

    This paper analyses how tradable emission permits should be allocated to firms when capital is internationally mobile. When international environmental problems are attempted solved through uncoordinated policies between countries, it might be desirable for the home country to issue free emission permits in proportion to the use of capital in order to prevent leakage through international capital movements. The desirability of free emission permits will however be reduced if capital also can be employed in a domestic non-polluting sector. In this case, it may even be optimal to tax the use of capital in the polluting sector. It is also shown that it is always optimal to subsidise the use of capital in the polluting sector if the use of labour is taxed at an optimal rate. Finally, leakage does not affect the optimal domestic emission limit as long as appropriate capital subsidies and labour taxes are implementeed. (author)

  6. Impact of the Indonesian Throughflow on Agulhas leakage

    Directory of Open Access Journals (Sweden)

    D. Le Bars

    2013-09-01

    Full Text Available Using ocean models of different complexity we show that opening the Indonesian Passage between the Pacific and the Indian oceans increases the input of Indian Ocean water into the South Atlantic via the Agulhas leakage. In a strongly eddying global ocean model this response results from an increased Agulhas Current transport and a constant proportion of Agulhas retroflection south of Africa. The leakage increases through an increased frequency of ring shedding events. In an idealized two-layer and flat-bottom eddy resolving model, the proportion of the Agulhas Current transport that retroflects is (for a wide range of wind stress forcing not affected by an opening of the Indonesian Passage. Using a comparison with a linear model and previous work on the retroflection problem, the result is explained as a balance between two mechanisms: decrease retroflection due to large-scale momentum balance and increase due to local barotropic/baroclinic instabilities.

  7. Combined approach to reduced duration integrated leakage rate testing

    International Nuclear Information System (INIS)

    Galanti, P.J.

    1987-01-01

    Even though primary reactor containment allowable leakage rates are expressed in weight percent per day of contained air, engineers have been attempting to define acceptable methods to test in < 24 h as long as these tests have been performed. The reasons to reduce testing duration are obvious, because time not generating electricity is time not generating revenue for the utilities. The latest proposed revision to 10CFR50 Appendix J, concerning integrated leakage rate testing (ILRTs), was supplemented with a draft regulatory guide proposing yet another method. This paper proposes a method that includes elements of currently accepted concepts for short duration testing with a standard statistical check for criteria acceptance. Following presentation of the method, several cases are presented showing the results of these combined criteria

  8. Correlation among ESDD, NSDD and leakage current in distribution insulators

    International Nuclear Information System (INIS)

    Montoya, G.; Ramirez, I.; Montoya, J.I.

    2004-01-01

    The maintenance of distribution networks is more effective if the insulation contamination levels are known. The selection of measuring methods of pollution levels is then crucial. The relationship between several evaluation methods of pollution levels and the operating behaviour of several insulator profiles in a polluted zone is described. Laboratory tests were carried out to reproduce pollution levels found in the field. The quantity of non-soluble materials deposited over the insulators' surface affect the magnitude of the leakage current generated over a contaminated insulator. The relationship that defines leakage current with respect to the equivalent salt deposit density (ESDD) level for a specific non-soluble material level is almost linear, from which it is possible to develop a relationship between them for each insulator. (author)

  9. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P.; Vranka, L. [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1997-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  10. Low-leakage, high-current power crowbar transformer

    International Nuclear Information System (INIS)

    Buck, R.T.; Galbraith, J.D.; Nunnally, W.C.

    1979-01-01

    The design, fabrication, and testing of two sizes of power crowbar transformers for the ZT-40 Toroidal Z-Pinch experiment at the Los Alamos Scientific Laboratory are described. Low-leakage transformers in series with the poloidal and the toroidal field coils are used to sustain magnetic field currents initially produced by 50-kV capacitor banks. The transformer primaries are driven by cost-effective, ignitron-switched, 10-kV high-density capacitor banks. The transformer secondaries, in series with the field coils, provide from 1,000 to 1,500 V to cancel the resistive voltage drop in the coil circuits. Prototype transformers, with a total leakage inductance measured in the secondary of 5 nH, have been tested with peak secondary currents in excess of 600 kA resulting from a 10-kV primary charge voltage. The test procedures and results and the mechanical construction details are presented

  11. The Impact of Statistical Leakage Models on Design Yield Estimation

    Directory of Open Access Journals (Sweden)

    Rouwaida Kanj

    2011-01-01

    Full Text Available Device mismatch and process variation models play a key role in determining the functionality and yield of sub-100 nm design. Average characteristics are often of interest, such as the average leakage current or the average read delay. However, detecting rare functional fails is critical for memory design and designers often seek techniques that enable accurately modeling such events. Extremely leaky devices can inflict functionality fails. The plurality of leaky devices on a bitline increase the dimensionality of the yield estimation problem. Simplified models are possible by adopting approximations to the underlying sum of lognormals. The implications of such approximations on tail probabilities may in turn bias the yield estimate. We review different closed form approximations and compare against the CDF matching method, which is shown to be most effective method for accurate statistical leakage modeling.

  12. Modelling of Consequences of Biogas Leakage from Gasholder

    Directory of Open Access Journals (Sweden)

    Petr Trávníček

    2017-03-01

    Full Text Available This paper describes modelling of consequences of biogas leakage from a gasholder on agricultural biogas station. Four scenarios were selected for the purpose of this work. A rupture of gasholders membrane and instantaneous explosion of gas cloud, blast of gas with delay, emptying of whole volume of gas (without initiation and initiation of gas with Jet-Fire. Leakage of gas is modelled by special software and consequences are determined on the basis of results. The first scenario was modelled with help of equations because used software does not include an appropriate model. A farm with high building density was chosen as a model case. Biogas is replaced by methane because used software does not support modelling of dispersion of mixtures. From this viewpoint, a conservative approach is applied because biogas contains “only” approximately 60% of methane (in dependence on technology and processed material.

  13. Mission analysis report for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides an analysis of the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall missions of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineers principles are being applied to this effort. Mission analysis supports early decision making by clearly defining program objectives. This documents identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and constraints, estimates the resources to carry out the mission, and establishes measures of success. The results of the mission analysis provide a consistent basis for subsequent systems engineering work

  14. The root caused analysis of leakaged heat exchanger tube

    International Nuclear Information System (INIS)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif; Harun, Mohd; Zayid, Hafizal; Noor, Mazlee Mohd

    2015-01-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  15. A software sampling frequency adaptive algorithm for reducing spectral leakage

    Institute of Scientific and Technical Information of China (English)

    PAN Li-dong; WANG Fei

    2006-01-01

    Spectral leakage caused by synchronous error in a nonsynchronous sampling system is an important cause that reduces the accuracy of spectral analysis and harmonic measurement.This paper presents a software sampling frequency adaptive algorithm that can obtain the actual signal frequency more accurately,and then adjusts sampling interval base on the frequency calculated by software algorithm and modifies sampling frequency adaptively.It can reduce synchronous error and impact of spectral leakage;thereby improving the accuracy of spectral analysis and harmonic measurement for power system signal where frequency changes slowly.This algorithm has high precision just like the simulations show,and it can be a practical method in power system harmonic analysis since it can be implemented easily.

  16. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran (Univ. of Gaevle, Gaevle (Sweden)); Meijer, Jan-Erik; Rosqvist, Haakan (NSR AB, Helsingborg (Sweden))

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  17. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P; Vranka, L [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1998-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  18. Practical implementation of a higher order transverse leakage approximation

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomašević

    2011-01-01

    Transverse integrated nodal diffusion methods currently represent the standard in full core neutronic simulation. The primary shortcoming in this approach, be it via the Analytic Nodal Method or Nodal Expansion Method, is the utilization of the quadratic transverse leakage approximation. This approach, although proven to work well for typical LWR problems, is not consistent with the formulation of nodal methods and can cause accuracy and convergence problems. In this work an improved, consistent quadratic leakage approximation is formulated, which derives from the class of higher order nodal methods developed some years ago. In this new approach, only information relevant to describing the transverse leak- age terms in the zero-order nodal equations are obtained from the higher order formalism. The method yields accuracy comparable to full higher order methods, but does not suffer from the same computational burden which these methods typically incur. (author)

  19. Air leakage test of reactor hall using tracer technique

    International Nuclear Information System (INIS)

    Yang Yanqiu; Yang Liang; Yang Tongzai

    2011-01-01

    The leakage ratios of three related reactor halls were tested by sulfur hexafluoride gaseous tracer technique. Moreover, the accumulation intensities of leak gas and its retention time in some important working rooms, the crossroads of corridors and anteroom of the building were detected. The results show that the air leakage ratios of the three reactor halls are (7.30±0.16) x 10 -4 , (1.88±0.12) x 10 -4 and (2.07±0.07) x 10 -4 h -1 . The leak gas accumulates in all the detected working rooms fast, and the retention time to various rooms is about 5 h. The heaviest intensities are in the clothes change rooms on the first floor. However, the retention time to the crossroads and the anteroom is about 10 h, and the accumulation intensities are much small. (authors)

  20. Effect of Ion Flux (Dose Rate) in Source-Drain Extension Ion Implantation for 10-nm Node FinFET and Beyond on 300/450mm Platforms

    Science.gov (United States)

    Shen, Ming-Yi

    with a lower wafer dose can be achieved. In addition, the leakage current might also be reduced due to less undesired dopants in the channel. However, the twin defects from the problematic Si{111} recrystallization is well-known to cause excessive leakage current to the FinFET. This drawback can offset the benefits of the high dose rate I/I mentioned above. This work produced the first attempt at simulating the electrical impact of twin defects on advanced-node (10 nm) FinFET device performance. It was found that the high dose-rate I/I causes more twin defects in the silicon fin, and the physical locations of these defects were close to the channel. The defects undesirably induced trap-assisted band-to-band tunneling near the drain, which increased the leakage current. This issue could be mitigated by using asymmetrical gate overlap/underlap design or thicker spacer for SDE I/I so that the twin defects are not located in the depletion region near the drain.