WorldWideScience

Sample records for double-antibody sandwich elisa

  1. ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors

    International Nuclear Information System (INIS)

    Wang Yiqing; Shi Zhixu

    2002-01-01

    Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors

  2. [A double antibody sandwich ELISA based assay for titration of severe fever with thrombocytopenia syndrome virus].

    Science.gov (United States)

    Liu, Lin; Zhang, Quan-Fu; Li, Chuan; Li, Jian-Dong; Jiang, Xiao-Lin; Zhang, Fu-Shun; Wu, Wei; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    To develop an assay for titration of severe fever with thrombocytopenia syndrome virus (SFTSV) based on double antibody sandwich ELISA. A double antibody sandwich ELISA was developed for detection of SFTSV based on SFTSV nucleocapsid (N) protein specific poly- and monoclonal antibodies, procedures were optimized and evaluated. This ELISA based titration assay was compared with fluorescence assasy and plaque assay based titration method. The results suggested that the titers obtained by ELISA based method are consistent with those obtained by IFA based method (R = 0.999) and the plaque assay titration method (R = 0.949). The novel ELISA based titration method with high sensitivity and specificity is easy to manage and perform, and can overcome the subjectivity associated with result determination of the fluorescence assay and plaque assay based methods. The novel ELISA based titration method can also be applied to high throughput detection.

  3. Construction, expression, purification and biotin labeling of a single recombinant multi-epitope antigen for double-antigen sandwich ELISA to detect hepatitis C virus antibody.

    Science.gov (United States)

    He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu

    2011-08-01

    Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.

  4. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  5. Development of monoclonal antibody-based sandwich ELISA for detection of dextran.

    Science.gov (United States)

    Wang, Sheng-Yu; Li, Zhe; Wang, Xian-Jiang; Lv, Sha; Yang, Yun; Zeng, Lian-Qiang; Luo, Fang-Hong; Yan, Jiang-Hua; Liang, Da-Feng

    2014-10-01

    Dextran as anti-nutritional factor is usually a result of bacteria activity and has associated serial problems during the process stream in the sugar industry and in medical therapy. A sensitive method is expected to detect dextran quantitatively. Here we generated four monoclonal antibodies (MAbs) against dextran using dextran T40 conjugated with bovine serum albumin (BSA) as immunogen in our lab following hybridoma protocol. Through pairwise, an MAb named D24 was determined to be conjugated with horseradish peroxidase (HRP) and was used in the establishment of a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) method for determination of dextran, in which MAb D9 was chosen as a capture antibody. The detection limit and working scope of the developed sandwich ELISA method were 3.9 ng/mL and 7.8-500 ng/mL with a correlation coefficient of 0.9909. In addition, the cross-reaction assay demonstrated that the method possessed high specificity with no significant cross-reaction with dextran-related substances, and the recovery rate ranged from 96.35 to 102.00%, with coefficient of variation ranging from 1.58 to 6.94%. These results indicated that we developed a detection system of MAb-based sandwich ELISA to measure dextran and this system should be a potential tool to determine dextran levels.

  6. Protein unfolding allows use of commercial antibodies in an apolipoprotein M sandwich ELISA

    DEFF Research Database (Denmark)

    Bosteen, Markus Høybye; Dahlbäck, Björn; Nielsen, Lars Bo

    2015-01-01

    that specifically recognizes human apoM in plasma using commercially available reagents. Commercial apoM antibodies were screened for compatibility in a sandwich ELISA-based assay. One optimal pair of antibodies was chosen, and sample preparation, buffers, and incubation times were optimized to generate a simple...... and reproducible method. Validation and comparison to a previously described ELISA for apoM confirmed that the assay displays a high degree of sensitivity, specificity, and precision. Our results show that commercially available antibodies can be used to accurately measure human plasma apoM. This method can...

  7. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) for antigen detection of foot-and-mouth disease virus using clinical samples.

    Science.gov (United States)

    Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru

    2014-01-01

    A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  8. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA for antigen detection of foot-and-mouth disease virus using clinical samples.

    Directory of Open Access Journals (Sweden)

    Kazuki Morioka

    Full Text Available A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA method was previously developed for foot-and-mouth disease (FMD viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01. In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01. Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  9. Immunodiagnostic monoclonal antibody-based sandwich ELISA of fasciolosis by detection of Fasciola gigantica circulating fatty acid binding protein.

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-09-01

    Up to now, parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Hence, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. In the present study, a monoclonal antibody (MoAb) against recombinant Fasciola gigantica fatty acid binding protein (rFgFABP) has been produced. As well, a reliable sandwich enzyme-linked immunosorbent assay (sandwich ELISA) has been developed for the detection of circulating FABP in the sera of mice experimentally and cattle naturally infected with F. gigantica. MoAb 3A3 and biotinylated rabbit anti-recombinant FABP antibody were selected due to their high reactivities and specificities. The lower detection limit of sandwich ELISA was 5 pg mL-1, and no cross-reaction with other parasite antigens was observed. This assay could detect F. gigantica infection from day 1 post infection. In experimental mice, the sensitivity, specificity and accuracy of this assay were 93·3, 100 and 98·2%, while in natural cattle they were 96·7, 100 and 99·1%. Hence, this sandwich ELISA method showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica.

  10. Development of indirect sandwich ELISA for determination of excretory-secretory antigens of Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Libertad Alzamora-Gonzales

    2016-05-01

    Full Text Available Fasciolosis is a cosmopolitan parasitosis medical-veterinary importance caused by Fasciola hepatica, which affects sheep, goats and cattle; and it affects man accidentally causing an epidemic-endemic infection difficult to diagnose. The aim was to develop an indirect sandwich ELISA with 3 antibodies for detecting excretory-secretory antigens of Fasciola hepatica (ESFh. For the development of indirect sandwich ELISA were used, as capture antibody, mouse polyclonal antibodies anti ESFh and polyclonal antibodies rabbit anti-ESFh as detection antibody, at the concentrations of 10 and 5 µg/mL respectively. The conjugate used was mouse monoclonal anti- total immunoglobulins rabbit linked to peroxidase (1/1000. Were analized 31 sheep fecal samples, and the results were compared with those obtained by direct coproparasitological examination (DC and counterimmunoelectrophoresis (CIEP. The detection limit obtained for indirect sandwich ELISA was 100 ng/mL. The test had a 100% sensitivity, 96.6% specificity, positive and negative predictive values of 50% and 96.6% respectively, in relation to DC test. Comparing with CIEP the specificity obtained for indirect sandwich ELISA was 93.5% and a negative predictive value of 100%. We concluded that indirect sandwich ELISA designed is able to detect metabolic antigens in ovine feces samples and can be used for Fasciola hepatica diagnosis.

  11. Development of a Monoclonal Antibody-Based Sandwich ELISA for Peanut Allergen Ara h 1 in Food

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-07-01

    Full Text Available We have established a highly sensitive sandwich enzyme-linked immunosorbent assay (ELISA based on two monoclonal antibodies (mAb to measure the content of the major peanut allergen Ara h 1 in foods. Two mAbs were selected out of 12 murine hybridoma cells secreting Ara h 1-specific antibody. Using mAb 6 as the capture antibody and HRP-labelled mAb 4 as the detection antibody, the limit of detection (LOD the assay was 0.34 ng/mL. Cross-reaction analysis showed that this method was strongly specific and had no cross-reactions with Ara h 2, pea protein or soy protein. Sample analysis showed that this ELISA was a useful tool to monitor peanut allergens in food products by measuring Ara h 1 content.

  12. Purification of a polyclonal antibody against CD147 for ELISA using antigen-immunoaffinity chromatography

    Science.gov (United States)

    Liu, Shuangshuang; Li, Shasha; Zhang, Yang; Wang, Ye; Zhu, Yumeng; Wang, Bin; Chen, Zhi-Nan

    2017-01-01

    The immunoglobulin superfamily member CD147 is a widely expressed glycoprotein that occurs in both a membrane-spanning and soluble form. Sandwich ELISA is a powerful tool for analyzing soluble antigens. The aim of the present study was to obtain a highly specific polyclonal antibody against human CD147 that can be used for sandwich ELISA analysis. Expression of recombinant CD147 by a eukaryotic expression system was used to immunize rabbits to obtain antiserum. A highly specific polyclonal antibody that was able to detect soluble CD147 in sandwich ELISA was obtained by antigen-immunoaffinity chromatography purification. The purity of rabbit anti-CD147 polyclonal antibodies was ~99%, and ELISA analysis was able to determine the titer of the rabbit anti-CD147 polyclonal antibodies at 1:512,000. The lowest concentration of the standard CD147 antigen that the sandwich ELISA was able to detect was 31.25 pg/ml. The sandwich ELISA system was composed of anti-hepatoma HAb18 monoclonal antibodies and purified rabbit anti-CD147 polyclonal antibodies. The present study demonstrated that antigen-immunoaffinity chromatography may be a good technique for the purification of polyclonal antibodies, which may be used to detect antigen in sandwich ELISAs. PMID:28487989

  13. Immunodiagnosis of Fasciola gigantica Infection Using Monoclonal Antibody-Based Sandwich ELISA and Immunochromatographic Assay for Detection of Circulating Cathepsin L1 Protease.

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-01-01

    Tropical fasciolosis caused by Fasciola gigantica infection is one of the major diseases infecting ruminants in the tropical regions of Africa and Asia including Thailand. Parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Therefore, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. In this study, we have produced a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1 (rFgCatL1), and developed both sandwich enzyme-linked immunosorbent assay (sandwich ELISA) and immunochromatographic (IC) test for rapid detection of circulating cathepsin L1 protease (CatL1) in the sera from mice experimentally and cattle naturally infected with Fasciola gigantica. MoAb 4E3 and biotinylated rabbit anti-recombinant CatL1 antibody were selected due to their high reactivities and specificities. The lower detection limits of sandwich ELISA and IC test were 3 pg/ml and 0.256 ng/ml, respectively. Sandwich ELISA and IC test could detect F. gigantica infection from day 1 to 35 post infection. In experimental mice, the sensitivity, specificity and accuracy were 95%, 100% and 98.6% (for sandwich ELISA), and 93%, 100% and 98.2% (for IC test), while in natural cattle they were 98.3%, 100% and 99.5% (for sandwich ELISA), and 96.7%, 100% and 99.1% (for IC test). These two assay methods showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica.

  14. Immunodiagnosis of Fasciola gigantica Infection Using Monoclonal Antibody-Based Sandwich ELISA and Immunochromatographic Assay for Detection of Circulating Cathepsin L1 Protease

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-01-01

    Background Tropical fasciolosis caused by Fasciola gigantica infection is one of the major diseases infecting ruminants in the tropical regions of Africa and Asia including Thailand. Parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Therefore, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. Methods In this study, we have produced a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1 (rFgCatL1), and developed both sandwich enzyme-linked immunosorbent assay (sandwich ELISA) and immunochromatographic (IC) test for rapid detection of circulating cathepsin L1 protease (CatL1) in the sera from mice experimentally and cattle naturally infected with Fasciola gigantica. MoAb 4E3 and biotinylated rabbit anti-recombinant CatL1 antibody were selected due to their high reactivities and specificities. Results The lower detection limits of sandwich ELISA and IC test were 3 pg/ml and 0.256 ng/ml, respectively. Sandwich ELISA and IC test could detect F. gigantica infection from day 1 to 35 post infection. In experimental mice, the sensitivity, specificity and accuracy were 95%, 100% and 98.6% (for sandwich ELISA), and 93%, 100% and 98.2% (for IC test), while in natural cattle they were 98.3%, 100% and 99.5% (for sandwich ELISA), and 96.7%, 100% and 99.1% (for IC test). Conclusions These two assay methods showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica. PMID:26731402

  15. Quantitative Detection of the Foot-And-Mouth Disease Virus Serotype O 146S Antigen for Vaccine Production Using a Double-Antibody Sandwich ELISA and Nonlinear Standard Curves.

    Directory of Open Access Journals (Sweden)

    Xia Feng

    Full Text Available The efficacy of an inactivated foot-and-mouth disease (FMD vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01. In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings.

  16. Quantitative Detection of the Foot-And-Mouth Disease Virus Serotype O 146S Antigen for Vaccine Production Using a Double-Antibody Sandwich ELISA and Nonlinear Standard Curves

    Science.gov (United States)

    Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao

    2016-01-01

    The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings. PMID:26930597

  17. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  18. Sandwich ELISA for quantitative detection of human collagen prolyl 4-hydroxylase

    Directory of Open Access Journals (Sweden)

    Myllyharju Johanna

    2010-06-01

    Full Text Available Abstract Background We describe a method for specific, quantitative and quick detection of human collagen prolyl 4-hydroxylase (C-P4H, the key enzyme for collagen prolyl-4 hydroxylation, in crude samples based on a sandwich ELISA principle. The method is relevant to active C-P4H level monitoring during recombinant C-P4H and collagen production in different expression systems. The assay proves to be specific for the active C-P4H α2β2 tetramer due to the use of antibodies against its both subunits. Thus in keeping with the method C-P4H is captured by coupled to an anti-α subunit antibody magnetic beads and an anti-β subunit antibody binds to the PDI/β subunit of the protein. Then the following holoenzyme detection is accomplished by a goat anti-rabbit IgG labeled with alkaline phosphatase which AP catalyzes the reaction of a substrate transformation with fluorescent signal generation. Results We applied an experimental design approach for the optimization of the antibody concentrations used in the sandwich ELISA. The assay sensitivity was 0.1 ng of C-P4H. The method was utilized for the analysis of C-P4H accumulation in crude cell extracts of E. coli overexpressing C-P4H. The sandwich ELISA signals obtained demonstrated a very good correlation with the detected protein activity levels measured with the standard radioactive assay. The developed assay was applied to optimize C-P4H production in E. coli Origami in a system where the C-P4H subunits expression acted under control by different promoters. The experiments performed in a shake flask fed-batch system (EnBase® verified earlier observations that cell density and oxygen supply are critical factors for the use of the inducer anhydrotetracycline and thus for the soluble C-P4H yield. Conclusions Here we show an example of sandwich ELISA usage for quantifying multimeric proteins. The method was developed for monitoring the amount of recombinant C-P4H tetramer in crude E. coli extracts. Due

  19. Preparation of anti-ciguatoxin monoclonal antibodies using synthetic haptens: sandwich ELISA detection of ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2014-01-01

    Ciguatera fish poisoning (CFP) is a form of food poisoning caused by the consumption of fish that have accumulated a type of sodium channel activator toxin called ciguatoxins (CTXs), which are produced by dinoflagellates of the genus Gambierdiscus through the food chain. CFP affects more than 50000 people each year. The extremely low level of CTXs in tainted fish has hampered the development of antibodies for the detection of these toxins. Monoclonal antibodies (mAbs) specific against major congeners of CTX3C, 51-hydroxyCTX3C, CTX1B, and 54-deoxyCTX1B were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens in place of the natural toxins. We found that haptenic groups possessing a surface area larger than 400 angstroms2 were required to produce mAbs that can bind strongly to CTXs. Direct sandwich ELISA utilizing two different monoclonal antibodies that bind specifically to one of the two wings of a CTX were established to detect CTXs. No cross-reactivity was observed against the other marine toxins tested, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  20. Development of a monoclonal antibody-based sandwich-type enzyme-linked immunosorbent assay (ELISA) for detection of abrin in food samples.

    Science.gov (United States)

    Zhou, Yu; Tian, Xiang-Li; Li, Yan-Song; Pan, Feng-Guang; Zhang, Yuan-Yuan; Zhang, Jun-Hui; Wang, Xin-Rui; Ren, Hong-Lin; Lu, Shi-Ying; Li, Zhao-Hui; Liu, Zeng-Shan; Chen, Qi-Jun; Liu, Jing-Qiu

    2012-12-15

    Abrin is a plant toxin, which can be easily isolated from the seeds of Abrus precatorius. It may be used as a biological warfare agent. In order to detect abrin in food samples, a two-layer sandwich format enzyme-linked immunosorbent assay based on the monoclonal antibody (mAb) (as capture antibody) and rabbit polyclonal serum (as detecting antibody) was developed and applied for the determination of abrin in some food matrices. The linear range of the mAb was 1-100 μg L(-1) with a detection limit of 0.5 μg L(-1) for abrin in phosphate buffered saline (PBS). The recoveries of abrin from sausage, beer and milk samples ranged 97.5-98.6%, 95.8-98.4% and 94.8-9.6%, respectively, with a coefficient of variation (CV) of 3.7% or less. The newly developed sandwich ELISA using the mAb appears to be a reliable and useful method for detection of abrin in sausage, beer and milk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Quantitative sandwich ELISA for the determination of fish in foods.

    Science.gov (United States)

    Faeste, Christiane K; Plassen, Christin

    2008-01-01

    Allergy to fish represents one of the most prevalent causes for severe food-allergic reactions. Therefore, food authorities in different countries have implemented mandatory labeling of fish in pre-packed foods. Detection of fish proteins in food has previously been based on the use of patient serum. In the present study, a novel sandwich enzyme-linked immunosorbent assay (ELISA) for the quantitation of fish in food matrixes has been developed and validated, using a polyclonal rabbit anti-cod parvalbumin antibody for capture and a biotinylated conjugate of the same antibody for detection. By employing the ubiquitous muscle protein parvalbumin as target the method succeeds to detect a variety of fish. However, the ELISA is specific for fish and does not cross-react with other species. Recoveries ranged from 68-138% in typical food matrixes, while the intra- and inter-assay precisions were parvalbumin ELISA with a limit of detection of 0.01 mg parvalbumin/kg food, about 5 mg fish/kg food, seems sufficient to detect fish protein traces in foods at levels low enough to minimize the risk for fish allergic consumers.

  2. Development of a sandwich ELISA for the thrombin light chain identified by serum proteome analysis

    Directory of Open Access Journals (Sweden)

    Kazuyuki Sogawa

    2017-08-01

    Full Text Available We previously identified novel biomarker candidates in biliary tract cancer (BTC using serum proteome analysis. Among several candidates, we focused on thrombin light chain which is a 4204 Da peptide as the most promising biomarker for BTC. To move thrombin light chain toward potential diagnostic use, we developed an enzyme immunoassay that enables to measure serum thrombin light chain levels.Both one monoclonal antibody specific to the N-termini and one polyclonal antibody were used to develop a sandwich ELISA for thrombin light chain. The assay was evaluated by comparing the results with those obtained by the ClinProt™ system. Serum samples were obtained from 20 patients with BTC, 20 patients with BBTDs and 20 HVs using the ClinProt™ system and ELISA.The results of the established ELISA showed a positive correlation with the findings by ClinProt™ system (slope=0.3386, intercept=34.901, r2=0.9641. The performance of the ELISA was satisfactory in terms of recovery (97.9–102.5% and within-run (1.5–4.8% and between-day (1.9–6.7% reproducibility. Serum thrombin light chain levels were significantly greater in BTC (176.5±47.2 ng/mL than in BBTDs (128.6±17.4 ng/mL and HVs (127.6±16.0 ng/mL (p<0.001.The sandwich ELISA developed in this study will be useful for validation of the diagnostic significance of serum thrombin light chain levels in various cancers. Keywords: Thrombin light chain, Biliary tract cancer, Sandwich ELISA, Serum biomarker

  3. Development of monoclonal antibodies against Sj29 and its possible application for schistosomiasis diagnosis

    Directory of Open Access Journals (Sweden)

    Cui-Ping Ren

    2017-08-01

    Conclusions: Sj29 double antibody sandwich ELISA was established. The specificity of this method for detecting healthy sera was 100%. Meanwhile, Sj29 sandwich ELISA may have a potential diagnostic capability to distinguish current from past infections and assess drug treatment responses.

  4. Diagnostic efficacy of monoclonal antibody based sandwich enzyme linked immunosorbent assay (ELISA for detection of Fasciola gigantica excretory/secretory antigens in both serum and stool

    Directory of Open Access Journals (Sweden)

    Zoheiry Mona K

    2011-09-01

    Full Text Available Abstract Background This research was carried out to develop a reliable monoclonal antibody (MoAb-based sandwich enzyme linked immunosorbent assay (ELISA for the diagnosis of active Fasciola gigantica infection in both serum and stool for comparative purposes. Methods From a panel of MoAbs raised against F. gigantica excretory/secretory antigens (ES Ags, a pair (12B/11D/3F and 10A/9D/10G was chosen due to its high reactivity and strict specificity to F. gigantica antigen by indirect ELISA. Results The two MoAbs were of the IgG1 and IgG2a subclasses, respectively. Using SDS-PAGE and EITB, the selected MoAbs recognized 83, 64, 45 and 26 kDa bands of ES Ags. The lower detection limit of ELISA assay was 3 ng/ml. In stool, the sensitivity, specificity and diagnostic efficacy of ELISA was 96%, 98.2 and 97.1%; while in serum they were 94%, 94.6% and 94.3%, respectively. Moreover, a positive correlation was found between ova count in stool of F. gigantica infected patients and the OD readings of ELISA in both stool and serum samples (r = 0.730, p Conclusions These data showed that the use of MoAb-based sandwich ELISA for the detection of F. gigantica coproantigens in stool specimens was superior to serum samples; it provides a highly efficient, non-invasive technique for the diagnosis of active F. gigantica infection.

  5. Hyperglucagonaemia analysed by glucagon sandwich ELISA

    DEFF Research Database (Denmark)

    Albrechtsen, Nicolai Jacob Wewer; Hartmann, Bolette; Veedfald, Simon

    2014-01-01

    the extent to which the hyperglucagonaemia measured in clinical samples was caused by authentic glucagon. METHODS: We examined the performance of three commercial glucagon 'sandwich' ELISAs. The ELISA with the best overall performance was selected to compare glucagon measurements in clinical samples...... sensitivity for glucagon in plasma (>10-20 pmol/l). Thus, only the third assay was suitable for measuring glucagon concentrations in clinical samples. The ELISA and RIA measured similar glucagon levels in healthy individuals. Measurements of samples from individuals with abnormally high (type 2 diabetes...... or obese) or very elevated (post vagotomy with pyloroplasty, post-RYGB) glucagon levels were also similar in both assays. However, glucagon levels in participants with ESRD were much lower when measured by ELISA than by RIA, indicating that the apparent hyperglucagonaemia is not caused by fully processed...

  6. Streptavidin-biotin-based directional double Nanobody sandwich ELISA for clinical rapid and sensitive detection of influenza H5N1.

    Science.gov (United States)

    Zhu, Min; Gong, Xue; Hu, Yonghong; Ou, Weijun; Wan, Yakun

    2014-12-20

    Influenza H5N1 is one subtype of the influenza A virus which can infect human bodies and lead to death. Timely diagnosis before its breakout is vital to the human health. The current clinical biochemical diagnosis for influenza virus are still flawed, and the diagnostic kits of H5N1 are mainly based on traditional monoclonal antibodies that hardly meet the requirements for clinical applications. Nanobody is a promising tool for diagnostics and treatment due to its smallest size, high specificity and stability. In this study, a novel Nanobody-based bioassay was developed for rapid, low-cost and sensitive detection of the influenza H5N1 virus. Nanobodies specific to H5N1 virus were selected from a VHH library by phage display technology. In this system, the biotinylated Nanobody was directionally captured by streptavidin coated on ELISA plate, which can specifically capture the H5N1 virus. Another Nanobody conjugated with HRP was used as a detector. A novel directional enzyme-linked immunosorbent assay for H5N1 using specific Nanobodies was established and compared to the conventional undirected ELISA assay. We have successfully constructed a high quality phage display Nanobody library and isolated two Nanobodies against H5N1 with high affinity and specificity. These two Nanobodies were further used to prepare the biosensor detection system. This streptavidin-biotin-based directional double Nanobodies sandwich ELISA for H5N1 detection showed superiority over the commonly undirectional ELISA protocol. The linear range of detection for standards in this immunoassay was approximately 50-1000 ng/mL and the detection limit was 14.1 ng/mL. The average recoveries of H5N1 virus from human serum samples were in the range from 94.58% to 114.51%, with a coefficient of variation less than 6.5%. Collectively, these results demonstrated that the proposed detection system is an alternative diagnostic tool that enables a rapid, inexpensive, sensitive and specific detection of the

  7. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Science.gov (United States)

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675

  8. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Directory of Open Access Journals (Sweden)

    Yanil R Parma

    2012-06-01

    Full Text Available Enterohemorrhagic Escherichia coli (EHEC, a subset of Shiga toxin producing E. coli (STEC is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS. Regardless of serotype, Shiga toxins (Stx1 and/or Stx2 are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx was developed using anti-Stx2 B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933 and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 400 ng /ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for 2 strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  9. Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

    OpenAIRE

    Richardson, M D; Stubbins, J M; Warnock, D W

    1982-01-01

    A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen ...

  10. A Monoclonal Antibody Based Capture ELISA for Botulinum Neurotoxin Serotype B: Toxin Detection in Food

    Directory of Open Access Journals (Sweden)

    Larry H. Stanker

    2013-11-01

    Full Text Available Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT, produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A–H have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD’s for individual antibodies ranging from 10 to 48 × 10−11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D., ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule and readily detects toxin in those food samples tested.

  11. A monoclonal antibody based capture ELISA for botulinum neurotoxin serotype B: toxin detection in food.

    Science.gov (United States)

    Stanker, Larry H; Scotcher, Miles C; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert

    2013-11-18

    Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A-H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD's) for individual antibodies ranging from 10 to 48 × 10-11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested.

  12. Efficacy demonstration of tetanus vaccines by double antigen ELISA.

    Science.gov (United States)

    Rosskopf, U; Noeske, K; Werner, E

    2005-09-01

    This paper describes a double antigen ELISA (DAE) for rapid, specific and reliable assessment of the antitetanus immune status of horses and sheep. Compared with the indirect ELISA, the double antigen ELISA has the advantage of species-independent testing of sera. Thanks to its test design, it is more specific since the detected antibodies are forced to bind tetanus toxoid twice. In addition, it is very sensitive to tetanus antibodies, enabling the detection of low antibody titres, in range which is relevant for the assessment of the protective status (tetanus toxin neutralising antibodies). The detection limit of the DAE for tetanus antibodies is in the order of 10(-4) EU/ml. A comparison of in vitro results of individual sera with in vivo titres showed that horse sera with titres of 0.04 and 0.05 EU/ml in the DAE showed titres of > 0.05 IU and 0.034 IU/ml respectively during in vivo testing thus indicating good agreement. For tested sheep sera which were rated > 0.05 IU/ml in vivo, the corresponding titre in the DAE was 0.24 EU/ml. Clear tetanus antitoxin establishment of protective ELISA limits requires further comparative examination of sera with low titres (tetanus vaccines ad us. vet. As a consequence, the toxin neutralisation test (still being the standard method of choice for quantifying tetanus toxin neutralising antitoxin titres) could be replaced, since it requires too great a number of animals per test and involves considerable suffering for the animals. The test described here reduces the use of mice and guinea pigs within vaccine efficacy testing. In addition, it involves less exposure of the laboratory personnel to toxin.

  13. Development of a monoclonal antibody against the left wing of ciguatoxin CTX1B: thiol strategy and detection using a sandwich ELISA.

    Science.gov (United States)

    Tsumuraya, Takeshi; Takeuchi, Katsutoshi; Yamashita, Shuji; Fujii, Ikuo; Hirama, Masahiro

    2012-09-01

    Ciguatera fish poisoning (CFP) is a form of food poisoning caused by the ingestion of a variety of reef fish that have accumulated trace amounts of ciguatoxins produced by dinoflagellates of the genus Gambierdiscus through the food chain. CFP affects more than 50,000 people each year. The extremely low level of the causative neurotoxins, ciguatoxins, in fish has hampered the preparation of antibodies for detecting the toxins. In this paper, we describe a thiol strategy for synthesizing a keyhole limpet hemocyanin (KLH)-conjugate (20) of the ABCDE-ring fragment of the Pacific ciguatoxins, CTX1B (1) and 54-deoxyCTX1B (4). We succeeded in producing a monoclonal antibody (3G8) against the left wings of these ciguatoxins by immunizing mice with the hapten-KLH conjugate (20) as the synthetic antigen. The most promising mAb, 3G8, does not cross-react with other related marine toxins. Sandwich enzyme-linked immunosorbent assay (ELISA) utilizing 3G8 and the previously prepared monoclonal antibody (8H4) enabled us to detect 1 specifically at less than 0.28 ng/mL. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Determination of Aspergillus pathogens in agricultural products by a specific nanobody-polyclonal antibody sandwich ELISA.

    Science.gov (United States)

    Wang, Ting; Li, Peiwu; Zhang, Qi; Zhang, Wen; Zhang, Zhaowei; Wang, Tong; He, Ting

    2017-06-28

    Aspergillus and its poisonous mycotoxins are distributed worldwide throughout the environment and are of particular interest in agriculture and food safety. In order to develop a specific method for rapid detection of Aspergillus flavus to forecast diseases and control aflatoxins, a nanobody, PO8-VHH, highly reactive to A. flavus was isolated from an immunized alpaca nanobody library by phage display. The nanobody was verified to bind to the components of extracellular and intracellular antigen from both A. flavus and A. parasiticus. To construct a sandwich format immunoassay, polyclonal antibodies against Aspergillus were raised with rabbits. Finally, a highly selective nanobody-polyclonal antibody sandwich enzyme-linked immunosorbent assay was optimized and developed. The results revealed that the detection limits of the two fungi were as low as 1 μg mL -1 , and that it is able to detect fungal concentrations below to 2 μg mg -1 of peanut and maize grains in both artificially and naturally contaminated samples. Therefore, we here provided a rapid and simple method for monitoring Aspergillus spp. contamination in agricultural products.

  15. Quantification in mass units of group 1 grass allergens by a monoclonal antibody-based sandwich ELISA.

    Science.gov (United States)

    Arilla, M C; Ibarrola, I; Eraso, E; Aguirre, M; Martínez, A; Asturias, J A

    2001-08-01

    Grass pollen extracts currently used for allergy diagnosis and immunotherapy are a complex mixture of proteins of which only a few have allergenic activity. Lol p 1 is one of the most important allergens in grass pollen extracts. To develop a two-site enzyme-linked immunosorbent assay for the quantification of Lol p 1 and other group 1 allergens from grass species, and to assess its suitability for quantifying this group of allergens. Balb/c mice immunized with recombinant Lol p 1 were used for the production of monoclonal antibodies. Screening of hybridomas was performed by direct ELISA, and selected monoclonal antibodies were immobilized on ELISA plates and incubated with samples containing group 1 allergens. Bound allergens were detected by a combination of biotinylated Lol p 1-specific monoclonal antibody and peroxidase-streptavidin conjugate. The assay is based on three Lol p 1-specific monoclonal antibodies with different epitope specificities. The optimized ELISA measured Lol p 1 concentrations ranging from 125 to 1000 ng/mL and could quantify group 1 allergen from grass species belonging to the Pooidea subfamily. The assay does not depend on anti-sera production or availability of human sera and thus reactives can be produced in unlimited amounts. This sensitive and specific Lol p 1 assay will be helpful both for quantifying the group 1 allergen content of Pooideae pollen extracts intended for clinical use and for studying cross-reactivities among pollen extracts.

  16. Extension of the ELISA method to the measurement of the specific radioactivity of viruses in crude cellular extracts

    Energy Technology Data Exchange (ETDEWEB)

    Konate, G; Fritig, B [Institut de Biologie Moleculaire et Cellulaire, 67-Strasbourg (France). Lab. de Virologie

    1983-06-01

    The double-antibody sandwich method of ELISA, which allows accurate quantitative determination of plant viruses, was extended to a radiochemical procedure which permits direct measurement of the specific radioactivity of virus labelled in vivo and present in very crude plant homogenates. Evidence is presented showing that 20 to 50% of the virus introduced in the polystyrene wells during the antigen incubation step could be trapped in the sandwich. The percentage of virus bound increased with the concentration of the coating antibody and was almost proportional to the concentration of the antigen and to the incubation time of the antigens. Complete dissociation of the double-antibody sandwich was achieved by incubation with 0.2 M KOH or NaOH (pH 13.3), and the label carried by the virus was measured by scintillation counting of the solubilization fluid. The ratio infected/healthy was much higher for the radiochemical procedure than for the immunosorbent assay itself since binding of the virus to the coating antibody was not accompanied by any nonspecific trapping of radioactive contaminants in the double-antibody sandwich. The procedure was highly sensitive since the background corresponded to the scintillation counting background. The detection of the label carried by tobacco mosaic virus was possible when the tobacco samples contained at least 5 ng of virus carrying a label as low as 40 dpm /sup 3/H or 20 dpm /sup 14/C.

  17. Development and evaluation of a sandwich ELISA for quantification of the 20S proteasome in human plasma

    DEFF Research Database (Denmark)

    Dutaud, Dominique; Aubry, Laurent; Henry, Laurent

    2002-01-01

    Because quantification of the 20S proteasome by functional activity measurements is difficult and inaccurate, we have developed an indirect sandwich enzyme-linked immunosorbent assays (ELISA) for quantification of the 20S proteasome in human plasma. This sandwich ELISA uses a combination...

  18. Iodoacetyl-functionalized pullulan: A supplemental enhancer for single-domain antibody-polyclonal antibody sandwich enzyme-linked immunosorbent assay for detection of survivin.

    Science.gov (United States)

    Matsushita, Takahiko; Arai, Hidenao; Koyama, Tetsuo; Hatano, Ken; Nemoto, Naoto; Matsuoka, Koji

    2017-11-01

    Survivin, an inhibitor of the apoptosis protein family, is a potent tumor marker for diagnosis and prognosis. The enzyme-linked immunosorbent assay (ELISA) is one of the methods that has been used for detection of survivin. However, ELISA has several disadvantages caused by the use of conventional antibodies, and we have therefore been trying to develop a novel ELISA system using camelid single-domain antibodies (VHHs) as advantageous replacements. Here we report a supplemental approach to improve the VHH-polyclonal antibody sandwich ELISA for survivin detection. Iodoacetyl-functionalized pullulan was synthesized, and its thiol reactivity was characterized by a model reaction with l-cysteine. The thiophilic pullulan was applied to an immunoassay asan additive upon coating of standard assay plates with an anti-survivin VHH fusion protein with C-terminal cysteine. The results showed that the mole ratio of the additive to VHH had a significant effect on the consequent response. Mole ratios of 0.07, 0.7, and 7 led to 90% lower, 15% higher, and 69% lower responses, respectively, than the response of a positive control in which no additive was used. The background levels observed in any additive conditions were as low as that of a negative control lacking both VHH and the additive. These results indicate the applicability of the thiol-reactive pullulan as a response enhancer to VHH-based ELISA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Characterization of ELISA Antibody-Antigen Interaction using Footprinting-Mass Spectrometry and Negative Staining Transmission Electron Microscopy

    Science.gov (United States)

    Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.

    2018-05-01

    We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.

  20. Characterization of ELISA Antibody-Antigen Interaction using Footprinting-Mass Spectrometry and Negative Staining Transmission Electron Microscopy

    Science.gov (United States)

    Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.

    2018-03-01

    We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.

  1. Validation of the FAO/IAEA/PANAFTOSA ELISA kit for determination of antibodies against foot-and-mouth disease virus

    International Nuclear Information System (INIS)

    Maradei, E.; Pedemonte, A.

    1998-01-01

    A Liquid phase blocking sandwich ELISA (LPBE) for the detection of foot-and-mouth disease (FMD) antibodies, serotypes O, A and C was validated using sera from bovines free of antibodies and vaccinated bovines. This technique proved to be sensitive and specific for the study of these antibodies. This kit has been prepared by the Pan American Foot-and-Mouth Disease Center (PAHO/WHO) in collaboration with the Animal Production and Health Section of the Joint FAO/IAEA Division, Vienna, Austria and the Institute for Animal Health in Pirbright, United Kingdom. (author)

  2. Development of a sandwich ELISA for quantification of immunoglobulin G in mink blood

    DEFF Research Database (Denmark)

    Mathiesen, Ronja; Chriél, Mariann; Struve, T.

    2016-01-01

    early immunity and thus their resistance against pathogenic agents found in the environment. This study describes a sandwich ELISA for quantification of the concentration of total immunoglobulin G in mink blood. The ELISA was validated with serum samples from females (n=8) and their kits (litters of 4...

  3. A High-Throughput, Precipitating Colorimetric Sandwich ELISA Microarray for Shiga Toxins

    Directory of Open Access Journals (Sweden)

    Andrew Gehring

    2014-06-01

    Full Text Available Shiga toxins 1 and 2 (Stx1 and Stx2 from Shiga toxin-producing E. coli (STEC bacteria were simultaneously detected with a newly developed, high-throughput antibody microarray platform. The proteinaceous toxins were immobilized and sandwiched between biorecognition elements (monoclonal antibodies and pooled horseradish peroxidase (HRP-conjugated monoclonal antibodies. Following the reaction of HRP with the precipitating chromogenic substrate (metal enhanced 3,3-diaminobenzidine tetrahydrochloride or DAB, the formation of a colored product was quantitatively measured with an inexpensive flatbed page scanner. The colorimetric ELISA microarray was demonstrated to detect Stx1 and Stx2 at levels as low as ~4.5 ng/mL within ~2 h of total assay time with a narrow linear dynamic range of ~1–2 orders of magnitude and saturation levels well above background. Stx1 and/or Stx2 produced by various strains of STEC were also detected following the treatment of cultured cells with mitomycin C (a toxin-inducing antibiotic and/or B-PER (a cell-disrupting, protein extraction reagent. Semi-quantitative detection of Shiga toxins was demonstrated to be sporadic among various STEC strains following incubation with mitomycin C; however, further reaction with B-PER generally resulted in the detection of or increased detection of Stx1, relative to Stx2, produced by STECs inoculated into either axenic broth culture or culture broth containing ground beef.

  4. A sandwich ELISA for measurement of the primary glucagon-like peptide-1 metabolite

    DEFF Research Database (Denmark)

    Wewer Albrechtsen, Nicolai J; Asmar, Ali; Jensen, Frederik

    2017-01-01

    developed a sandwich ELISA recognizing both GLP-1 9-36NH2 and nonamidated GLP-1 9-37. The ELISA was validated using analytical assay validation guidelines and by comparing it to a subtraction-based method, hitherto employed for estimation of GLP-1 9-36NH2 Its accuracy was evaluated from measurements...

  5. Quantification of Pla or 3, a Platanus orientalis Allergen, Grown under Different Environmental Conditions, by Sandwich ELISA.

    Science.gov (United States)

    Sedghy, Farnaz; Sankian, Mojtaba; Moghadam, Maliheh; Varasteh, Abdol-Reza

    2016-10-01

    Platanus species are widely cultured around the world and considered an important cause of allergic reactions. In the present study, we developed a sandwich ELISA to quantify Pla or 3 allergen in P. orientalis pollen extracts grown near high-traffic roads and compared it to pollen extracts collected from rural areas as control. Pollen samples were collected from three polluted and two unpolluted sites in Mashhad, northeast Iran. Recombinant Pla or 3 was expressed and used for polyclonal antibody production in rabbit. A sandwich ELISA was developed and validated to quantify Pla or 3 levels in pollen extracts from the different sites. The coefficients of variation (CVs) for the intra- and inter- day assays were less than 5 and 18%, respectively. The working range of the standard curve was between 0.1 and 25 ng/ml, with the detection limit being 0.037 ng/ml. The recovery percentage was 88-106.4% at working concentrations from 0.31 to 26.5 ng/ml. Pla or 3 levels were significantly greater in pollens grown near high-traffic roads than in those grown in rural regions (p Pla or 3 in pollen extracts. Using this validated ELISA, we showed a substantial difference between the amounts of Pla or 3 in pollens grown in different environments. This finding should be considered in developing public policies to reduce traffic pollution, which leads to reduced allergic reactions in atopic subjects.

  6. Optimisation of sandwich ELISA based on monoclonal antibodies for the specific measurement of pregnancy-associated plasma protein (PAPP-A) in acute coronary syndrome

    DEFF Research Database (Denmark)

    Rossen, Marie; Iversen, Kasper; Teisner, Ane

    2007-01-01

    OBJECTIVES: PAPP-A has become the principal biochemical serum marker in first trimester screening for Down syndrome, the original data being based on results of a radioimmunoassay (RIA). Recent observations using sandwich ELISA technology have proposed PAPP-A as a potential marker in patients wit...

  7. Detection of Antibodies to U.S. Isolates of Avian Pneumovirus by a Recombinant Nucleocapsid Protein-Based Sandwich Enzyme-Linked Immunosorbent Assay

    OpenAIRE

    Gulati, Baldev R.; Munir, Shirin; Patnayak, Devi P.; Goyal, Sagar M.; Kapur, Vivek

    2001-01-01

    The nucleocapsid (N) protein of subgroup C (United States-specific) avian pneumovirus (APV/US) was expressed in Escherichia coli, and antibodies to the recombinant N protein were shown to specifically recognize the ≈47-kDa N protein of APV/US by Western immunoblot analysis. The recombinant APV/US N protein was used in a sandwich-capture enzyme-linked immunosorbent assay (ELISA), and the resulting assay was found to be more sensitive and specific than the routine indirect ELISA for the detecti...

  8. Transferability of antibody pairs from ELISA to fiber optic surface plasmon resonance for infliximab detection

    Science.gov (United States)

    Van Stappen, Thomas; Lu, Jiadi; Bloemen, Maarten; Geukens, Nick; Spasic, Dragana; Delport, Filip; Verbiest, Thierry; Lammertyn, Jeroen; Gils, Ann

    2015-03-01

    Tumor necrosis factor (TNF)-alpha is a pleiotropic cytokine up-regulated in inflammatory bowel disease, rheumatoid arthritis and psoriasis. The introduction of anti-TNF drugs such as infliximab has revolutionized the treatment of these diseases. Recently, therapeutic drug monitoring (TDM) of infliximab has been introduced in clinical decision making to increase cost-efficiency. Nowadays, TDM is performed using radio-immunoassays, homogeneous mobility shift assays or ELISA. Unfortunately, these assays do not allow for in situ treatment optimization, because of the required sample transportation to centralized laboratories and the subsequent assay execution time. In this perspective, we evaluated the potential of fiber optic-surface plasmon resonance (FO-SPR). To achieve this goal, a panel of 55 monoclonal anti-infliximab antibodies (MA-IFX) was developed and characterized in-house, leading to the identification of nine different clusters. Based on this high diversity, 22 antibody pairs were selected and tested for their reactivity towards IFX, using one MA-IFX as capture and one MA-IFX for detection, in a sandwich type ELISA and FO-SPR. This study showed that the reactivity towards IFX of each antibody pair in ELISA is highly similar to its reactivity on FO-SPR, indicating that antibody pairs are easily transferable between both platforms. Given the fact that FO-SPR shows the potential for miniaturization and fast assay time, it can be considered a highly promising platform for on-site infliximab monitoring.

  9. A novel sandwich enzyme-linked immunosorbent assay with covalently bound monoclonal antibody and gold probe for sensitive and rapid detection of bovine β-lactoglobulin.

    Science.gov (United States)

    He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing

    2018-06-01

    Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3  ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.

  10. Production of monoclonal antibodies for sandwich immunoassay detection of ciguatoxin 51-hydroxyCTX3C.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Inoue, Masayuki; Tatami, Atsushi; Miyazaki, Keisuke; Hirama, Masahiro

    2006-09-01

    Every year, more than 50,000 people in subtropical and tropical regions suffer from ciguatera seafood poisoning. The extremely low level of the causative neurotoxins (ciguatoxins) in fish has hampered the preparation of antibodies for detection of the toxins. In this study, we produced a monoclonal antibody (8H4) against the right end of ciguatoxin CTX1B (1) and 51-hydroxyCTX3C (3) by immunizing mice with the keyhole limpet hemocyanin-conjugate of the synthetic HIJKLM ring fragment (10). We used 8H4 and another previously reported monoclonal antibody (10C9) that recognizes the left end of 3 to develop a sandwich enzyme-linked immunosorbent assay (ELISA) to detect 3. The assay could detect 3 down to the ppb level and lacked cross-reactivity with other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  11. An ELISA test for the detection of antibodies to Legionella pneumophila.

    OpenAIRE

    Wreghitt, T G; Nagington, J; Gray, J

    1982-01-01

    An enzyme-linked immunosorbent assay (ELISA) test has been developed to detect antibodies to Legionella pneumophila serogroup 1. There is good correlation between indirect fluorescent antibody (IFA) and ELISA titres but ELISA is more sensitive.

  12. Comparison of Laboratory-Developed and Commercial Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assays for Almond (Prunus dulcis) Detection and Quantification.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K

    2017-10-01

    A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection almond, limit of quantification almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.

  13. The use of enzyme-linked immunosorbent assay systems for the serology and antigen detection in parvovirus, coronavirus and rotavirus infections in dogs in The Netherlands.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); J. Groen (Jan); H.F. Egberink (Herman); G.H.A. Borst (Gerrit); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1991-01-01

    textabstractComplex trapping blocking (CTB) enzyme-linked immunosorbent assays (ELISAs) and indirect ELISAs for the detection of antibodies to canine parvovirus (CPV), canine coronavirus (CCV) and rotavirus in sera of dogs were established. Double antibody sandwich ELISAs for the detection of CPV-,

  14. Development and primary application of ELISA method for detecting residual calf serum protein

    International Nuclear Information System (INIS)

    Li Hua; Yu Jiankun; Hong Chao; Long Ruixiang; Zhai Yougang; Xu Qiongfang; Cui Pingfang; Ding Xuefeng; Xie Zhongping

    2005-01-01

    To develop a new DAS-ELISA (double antibody sandwich ELISA) kit for detecting residual calf serum protein (CSP) in vaccines, calf sera from different district were pooled and used to immunize rabbits and hens respectively. Then, the IgY from yolk and the anti-CSP IgG from rabbit were separated and purified. The purified IgY was used as the coating antibody, and purified rabbit anti-CSP IgG was labeled by HRP. The optimal concentration of IgY was 25-30 μg/mL. The coating buffer was 0.01mol/L PBS(pH7.4) containing 0.4% glutin. The optimal dilutions of HRP-IgG were from 1:2000 to 1:3000. The sensitivity of this ELISA method was higher (up to 2.5μg/mL) than that of current RPHA, the variation coefficient was about 6.3%-9.4%, and the recovery rate was 90.4%-112.8%. Furthermore, there was no cross-reaction with sera of pig, monkey and guinea pig. Twenty lots of vaccines with Al(OH) 3 or without Al(OH) 3 were tested by ELISA and RPHA respectively. The results proved that the adjuvant of Al(OH) 3 had fewer influence on ELISA than on RPHA, the variation of PRHA among different lots of vaccines was more significant than ELISA. The ELISA method is a highly sensitive and useful method to detect CSP in vaccines. (authors)

  15. Development of monoclonal antibodies and quantitative ELISAs targeting insulin-degrading enzyme

    Directory of Open Access Journals (Sweden)

    Dickson Dennis W

    2009-10-01

    Full Text Available Abstract Background Insulin-degrading enzyme (IDE is a widely studied zinc-metalloprotease implicated in the pathogenesis of type 2 diabetes mellitus, Alzheimer disease (AD and varicella zoster virus infection. Despite more than six decades of research on IDE, progress has been hampered by the lack of well-characterized reagents targeting this biomedically important protease. To address this important need, we generated and characterized new mouse monoclonal antibodies (mAbs targeting natively folded human and rodent IDE. Results Eight monoclonal hybridoma cell lines were derived in house from mice immunized with full-length, natively folded, recombinant human IDE. The mAbs derived from these lines were shown to detect IDE selectively and sensitively by a wide range of methods. Two mAbs in particular—designated 6A1 and 6H9—proved especially selective for IDE in immunocytochemical and immunohistochemical applications. Using a variety of methods, we show that 6A1 selectively detects both human and rodent IDE, while 6H9 selectively detects human, but not rodent, IDE, with both mAbs showing essentially no cross reactivity with other proteins in these applications. Using these novel anti-IDE mAbs, we also developed sensitive and quantitative sandwich ELISAs capable of quantifying IDE levels present in human brain extracts. Conclusion We succeeded in developing novel mAbs that selectively detect rodent and/or human IDE, which we have shown to be suitable for a wide range of applications, including western blotting, immunoprecipitation, immunocytochemistry, immunohistochemistry, and quantitative sandwich ELISAs. These novel anti-IDE mAbs and the assays derived from them constitute important new tools for addressing many unresolved questions about the basic biology of IDE and its role in multiple highly prevalent human diseases.

  16. The use of monoclonal antibodies in competitive ELISA for the detection of antibodies to rinderpest and peste des petits ruminants viruses

    International Nuclear Information System (INIS)

    Anderson, J.; McKay, J.A.; Butcher, R.N.

    1991-01-01

    A monoclonal antibody against the haemagglutinin of rinderpest virus has been used in a competitive ELISA (C-ELISA) for the detection of antibodies to rinderpest virus in cattle, sheep, goat and game sera. Unlike the indirect ELISA and the virus neutralisation test (VNT), the C-ELISA detects only antibodies to rinderpest virus and gives no cross-reactivity with antibodies to peste des petits ruminants (PPR) virus. Antibodies to a wide range of strains of rinderpest virus have been detected using this assay, suggesting its suitability for both sero-monitoring and sero-surveillance. Analysis of C-ELISA results from the examination of field sera shows a much greater separation of negative and positive populations as compared to the indirect ELISA. A further monoclonal antibody against the H protein of PPR has also been found suitable for use in a C-ELISA for the detection of antibodies to PPR virus. The use of these two C-ELISA's has made possible rapid differential sero-diagnosis without recourse to cross-VNT testing. The use of monoclonal antibody-based assays will allow much greater standardisation of rinderpest and PPR diagnosis, and following field-trials the C-ELISA will replace the indirect ELISA for sero-monitoring throughout the Pan African Rinderpest Campaign. (author). 3 refs, 6 figs, 1 tab

  17. Production of monoclonal antibodies for sandwich immunoassay detection of Pacific ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2010-10-01

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of Pacific ciguatoxins CTX3C and 51-hydroxyCTX3C were prepared by immunization of mice with the protein conjugates of rationally designed synthetic haptens in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C or 51-hydroxyCTX3C. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C and 51-hydroxyCTX3C at the ppb level with no cross-reactivity against the other marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin. Copyright 2009 Elsevier Ltd. All rights reserved.

  18. Detection of potato mop-top virus in soils and potato tubers using bait-plant bioassay, ELISA and RT-PCR.

    Science.gov (United States)

    Arif, Muhammad; Ali, Murad; Rehman, Anayatur; Fahim, Muhammad

    2014-01-01

    The hilly region of Northwest of Pakistan is leading seed potato producing areas of the country. Soil and plant samples were collected from the region and tested for PMTV using both conventional and molecular techniques. The bait plants exhibited PMTV-characteristic v-shaped yellow leaf markings in Nicotiana debneyi plants grown in putative viruliferious soils from 20/26 locations. The results were confirmed by back inoculation of sap from both roots and leaves of bait plant on indicator hosts (N. debneyi, Nicotiana benthamiana). The root samples of bait plants grown in soils of 25 locations and leaves of 24 locations reproduced systemic infection on indicator hosts upon back inoculation. The virus was identified in bait plants grown in soils from 25/26 locations using double antibody sandwich-enzyme linked immunosorbent assay (DAS)-ELISA and reverse transcription and polymerase chain reaction (RT-PCR) methods. The products of the 566bp were amplified from coat protein region of PMTV RNA 3 in both root and leaf samples of baited plants. The virus was detected in 10 potato cultivars commercially grown in the region using DAS-ELISA and RT-PCR. The virus was also detected in zoospores of Spongospora subterranea derived from the peels of selected scabby tubers using triple antibody sandwich (TAS)-ELISA. The results indicate that a bait plant bioassay, infectivity assay, ELISA and RT-PCR can detect PMTV in roots and leaves of baited plants, field samples, zoospores of S. subterranea and tubers of 10 potato cultivars commercially grown in the region. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Pistachio (Pistacia vera L.) Detection and Quantification Using a Murine Monoclonal Antibody-Based Direct Sandwich Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Sathe, Shridhar K

    2015-10-21

    A commercially available direct sandwich enzyme-linked immunosorbent assay (ELISA) (BioFront Technologies, Tallahassee, FL, USA) using murine anti-pistachio monoclonal antibodies (mAbs) as capture and detection antibodies was evaluated. The assay was sensitive (limit of detection = 0.09 ± 0.02 ppm full fat pistachio, linear detection range = 0.5-36 ppm, 50% maximum signal concentration = 7.9 ± 0.7 ppm), reproducible (intra- and inter-assay variability pistachio seeds subjected to autoclaving (121 °C, 15 psi, 15, 30 min), blanching (100 °C, 5, 10 min), frying (191 °C, 1 min), microwaving (500, 1000 W, 3 min), and dry roasting (140 °C, 30 min; 168 °C, 12 min). No cross-reactivity was observed in 156 food matrices, each tested at 100,000 ppm, suggesting the ELISA to be pistachio specific. The pistachio recovery ranges for spiked (10 ppm) and incurred (10-50000 ppm) food matrices were 93.1-125.6% and 35.7-112.2%, respectively. The assay did not register any false-positive or -negative results among the tested commercial and laboratory prepared samples.

  20. Implementation of microfluidic sandwich ELISA for superior detection of plant pathogens.

    Science.gov (United States)

    Thaitrong, Numrin; Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Karoonuthaisiri, Nitsara

    2013-01-01

    Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac), watermelon silver mottle virus (WSMoV), and melon yellow spot virus (MYSV) screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5-10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.

  1. Implementation of microfluidic sandwich ELISA for superior detection of plant pathogens.

    Directory of Open Access Journals (Sweden)

    Numrin Thaitrong

    Full Text Available Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac, watermelon silver mottle virus (WSMoV, and melon yellow spot virus (MYSV screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5-10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.

  2. Antibody-nanoparticle conjugates to enhance the sensitivity of ELISA-based detection methods.

    Directory of Open Access Journals (Sweden)

    Margaret M Billingsley

    Full Text Available Accurate antigen detection is imperative for clinicians to diagnose disease, assess treatment success, and predict patient prognosis. The most common technique used for the detection of disease-associated biomarkers is the enzyme linked immunosorbent assay (ELISA. In an ELISA, primary antibodies are incubated with biological samples containing the biomarker of interest. Then, detectible secondary antibodies conjugated with horseradish peroxidase (HRP bind the primary antibodies. Upon addition of a color-changing substrate, the samples provide a colorimetric signal that directly correlates to the targeted biomarker concentration. While ELISAs are effective for analyzing samples with high biomarker content, they lack the sensitivity required to analyze samples with low antigen levels. We hypothesized that the sensitivity of ELISAs could be enhanced by replacing freely delivered primary antibodies with antibody-nanoparticle conjugates that provide excess binding sites for detectible secondary antibodies, ultimately leading to increased signal. Here, we investigated the use of nanoshells (NS decorated with antibodies specific to epidermal growth factor receptor (EGFR as a model system (EGFR-NS. We incubated one healthy and two breast cancer cell lines, each expressing different levels of EGFR, with EGFR-NS, untargeted NS, or unconjugated EGFR antibodies, as well as detectable secondary antibodies. We found that EGFR-NS consistently increased signal intensity relative to unconjugated EGFR antibodies, with a substantial 13-fold enhancement from cells expressing high levels of EGFR. Additionally, 40x more unconjugated antibodies were required to detect EGFR compared to those conjugated to NS. Our results demonstrate that antibody-nanoparticle conjugates lower the detection limit of traditional ELISAs and support further investigation of this strategy with other antibodies and nanoparticles. Owing to their enhanced sensitivity, we anticipate that

  3. A commercial ELISA detects high levels of human H5 antibody but cross-reacts with influenza A antibodies.

    Science.gov (United States)

    Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D

    2008-10-01

    Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.

  4. Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies

    Directory of Open Access Journals (Sweden)

    Elza FT Belo

    Full Text Available Dot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic. The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required.

  5. Production of Polyclonal Antibody against Grapevine fanleaf virus Movement Protein Expressed in Escherichia coli

    Directory of Open Access Journals (Sweden)

    Davoud Koolivand

    2016-10-01

    Full Text Available The genomic region of Grapevine fanleaf virus (GFLV encoding the movement protein (MP was cloned into pET21a and transformed into Escherichia coli strain BL21 (DE3 to express the protein. Induction was made with a wide range of isopropyl-β-D-thiogalactopyranoside (IPTG concentrations (1, 1.5, and 2 mM each for duration of 4, 6, or 16 h. However, the highest expression level was achieved with 1 mM IPTG for 4 h. Identity of the expressed protein was confirmed by sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE followed by Western blotting. The expressed 41 kDa protein was purified under denaturing condition by affinity chromatography, reconfirmed by Western blotting and plate-trapped antigen enzyme-linked immunosorbent assay (PTA-ELISA before being used as a recombinant antigen to raise polyclonal antibodies in rabbits. Purified anti-GFLV MP immunoglobulines (IgGs and conjugated IgGs detected the expressed MP and GFLV virions in infected grapevines when used in PTA-ELISA, double antibody sandwich-ELISA, and Western blotting. This is the first report on the production of anti-GFLV MP polyclonal antibodies and application for the virus detection.

  6. Monoclonal antibodies against human angiotensinogen, their characterization and use in an angiotensinogen enzyme linked immunosorbent assay.

    Science.gov (United States)

    Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M

    1988-01-01

    Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.

  7. Characterization of novel monoclonal antibodies against the MERS-coronavirus spike protein and their application in species-independent antibody detection by competitive ELISA.

    Science.gov (United States)

    Fukushi, Shuetsu; Fukuma, Aiko; Kurosu, Takeshi; Watanabe, Shumpei; Shimojima, Masayuki; Shirato, Kazuya; Iwata-Yoshikawa, Naoko; Nagata, Noriyo; Ohnishi, Kazuo; Ato, Manabu; Melaku, Simenew Keskes; Sentsui, Hiroshi; Saijo, Masayuki

    2018-01-01

    Since discovering the Middle East respiratory syndrome coronavirus (MERS-CoV) as a causative agent of severe respiratory illness in the Middle East in 2012, serological testing has been conducted to assess antibody responses in patients and to investigate the zoonotic reservoir of the virus. Although the virus neutralization test is the gold standard assay for MERS diagnosis and for investigating the zoonotic reservoir, it uses live virus and so must be performed in high containment laboratories. Competitive ELISA (cELISA), in which a labeled monoclonal antibody (MAb) competes with test serum antibodies for target epitopes, may be a suitable alternative because it detects antibodies in a species-independent manner. In this study, novel MAbs against the spike protein of MERS-CoV were produced and characterized. One of these MAbs was used to develop a cELISA. The cELISA detected MERS-CoV-specific antibodies in sera from MERS-CoV-infected rats and rabbits immunized with the spike protein of MERS-CoV. The MAb-based cELISA was validated using sera from Ethiopian dromedary camels. Relative to the neutralization test, the cELISA detected MERS-CoV-specific antibodies in 66 Ethiopian dromedary camels with a sensitivity and specificity of 98% and 100%, respectively. The cELISA and neutralization test results correlated well (Pearson's correlation coefficients=0.71-0.76, depending on the cELISA serum dilution). This cELISA may be useful for MERS epidemiological investigations on MERS-CoV infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Sensitivity of some Immunoglobulin G class and subclass antibodies ...

    African Journals Online (AJOL)

    Indirect sandwich enzyme-linked immunosorbent assay (ELISA) was used to measure serum antibody responses in onchocerciasis patients. Apparently, IgG antibody class was more sensitive than IgG1, IgG3 and IgG4 responses to Onchocerca volvulus adult worms sodium duodecyl sulphate (SDS) extracted crude ...

  9. Detection of antibodies to the 20s proteasome by ELISA

    DEFF Research Database (Denmark)

    Jørgensen, Karin Meinike; Frederiksen, Jette Lautrup; Nielsen, Christoffer Tandrup

    2013-01-01

    The presence of antibodies against the 20S proteasome has been correlated with diseases like multiple sclerosis (MS) and systemic lupus erythematosus (SLE) but no definite association has been established. In order to investigate this further, we optimized an ELISA for proteasome antibodies...

  10. A novel electrochemical aptamer-antibody sandwich assay for lysozyme detection.

    Science.gov (United States)

    Ocaña, Cristina; Hayat, Akhtar; Mishra, Rupesh; Vasilescu, Alina; del Valle, Manel; Marty, Jean-Louis

    2015-06-21

    In this paper, we have reported a novel electrochemical aptamer-antibody based sandwich biosensor for the detection of lysozyme. In the sensing strategy, an anti-lysozyme aptamer was immobilized onto the carbon electrode surface by covalent binding via diazonium salt chemistry. After incubating with a target protein (lysozyme), a biotinylated antibody was used to complete the sandwich format. The subsequent additions of avidin-alkaline phosphatase as an enzyme label, and a 1-naphthyl phosphate substrate (1-NPP) allowed us to determine the concentration of lysozyme (Lys) via Differential Pulse Voltammetry (DPV) of the generated enzyme reaction product, 1-naphthol. Using this strategy, a wide detection range from 5 fM to 5 nM was obtained for a target lysozyme, with a detection limit of 4.3 fM. The control experiments were carried out by using bovine serum albumin (BSA), cytochrome c and casein. The results showed that the proposed biosensor had good specificity, stability and reproducibility for lysozyme analysis. In addition, the biosensor was applied for detecting lysozyme in spiked wine samples, and very good recovery rates were obtained in the range from 95.2 to 102.0% for lysozyme detection. This implies that the proposed sandwich biosensor is a promising analytical tool for the analysis of lysozyme in real samples.

  11. A simple sandwich ELISA (WELYSSA) for the detection of lyssavirus nucleocapsid in rabies suspected specimens using mouse monoclonal antibodies.

    Science.gov (United States)

    Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve

    2007-10-01

    Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.

  12. AN ELISA ASSAY FOR HEME OXYGENASE (HO-1)

    Science.gov (United States)

    An ELISA assay for heme oxygenase (HO-l ) Abstract A double antibody capture ELISA for the HO-l protein has been developed to separately quantitate HO-I protein. The use of 2.5% NP40 detergent greatly assists in freeing HO-l protein from membranes and/or other cel...

  13. Influence of affinity on antibody determination in microtiter ELISA systems

    International Nuclear Information System (INIS)

    Peterman, J.H.; Voss, E.W. Jr.; Butler, J.E.

    1986-01-01

    Theoretically, all immunoassays are affinity (Ka) dependent when the product of the antibody (Ab) Ka and the free epitope concentration is less than 10. Thus, the degree of dependence on Ka depends on the concentration of available antigen in the system. The authors examined the binding of 125 I-anti-fluorescein (a-FLU) monoclonal antibodies of different affinities to FLU-gelatin adsorbed on Immunlon 2 microtiter plates. Data obtained were in general agreement with our theoretical predictions; the percent of 125 I-a-FLU which bound correlated with Ka, as did the shape of the titration curves. Measurement of 5 a-FLU monoclonals by the ELISA showed that the determination of Ab concentrations depends on the FLU-gelatin concentration, epitope density, and on the relationship between the Kas of test samples and the reference standard Ab preparation. Thus the ELISA is Ka dependent and should not be used routinely to estimate the absolute amount to Ab in unknown samples. However, the Ka dependency of the ELISA might provide a convenient assay for the estimation of the relative functional Ka (rfKa) of antibody preparations

  14. Replacement of Antibodies in Pseudo-ELISAs: Molecularly Imprinted Nanoparticles for Vancomycin Detection.

    Science.gov (United States)

    Canfarotta, Francesco; Smolinska-Kempisty, Katarzyna; Piletsky, Sergey

    2017-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a widely employed analytical test used to quantify a given molecule. It relies on the use of specific antibodies, linked to an enzyme, to target the desired molecule. The reaction between the enzyme and its substrate gives rise to the analytical signal that can be quantified. Thanks to their robustness and low cost, molecularly imprinted polymer nanoparticles (nanoMIPs) are a viable alternative to antibodies. Herein, we describe the synthesis of nanoMIPs imprinted for vancomycin and their subsequent application in an ELISA-like format for direct replacement of antibodies.

  15. Development of a species-specific coproantigen ELISA for human Taenia solium taeniasis.

    Science.gov (United States)

    Guezala, Maria-Claudia; Rodriguez, Silvia; Zamora, Humberto; Garcia, Hector H; Gonzalez, Armando E; Tembo, Alice; Allan, James C; Craig, Philip S

    2009-09-01

    Taenia solium causes human neurocysticercosis and is endemic in underdeveloped countries where backyard pig keeping is common. Microscopic fecal diagnostic methods for human T. solium taeniasis are not very sensitive, and Taenia saginata and Taenia solium eggs are indistinguishable under the light microscope. Coproantigen (CoAg) ELISA methods are very sensitive, but currently only genus (Taenia) specific. This paper describes the development of a highly species-specific coproantigen ELISA test to detect T. solium intestinal taeniasis. Sensitivity was maintained using a capture antibody of rabbit IgG against T. solium adult whole worm somatic extract, whereas species specificity was achieved by utilization of an enzyme-conjugated rabbit IgG against T. solium adult excretory-secretory (ES) antigen. A known panel of positive and negative human fecal samples was tested with this hybrid sandwich ELISA. The ELISA test gave 100% specificity and 96.4% sensitivity for T. solium tapeworm carriers (N = 28), with a J index of 0.96. This simple ELISA incorporating anti-adult somatic and anti-adult ES antibodies provides the first potentially species-specific coproantigen test for human T. solium taeniasis.

  16. Bulk tank milk ELISA for detection of antibodies to Mycobacterium avium subsp paratuberculosis: Correlation between repeated tests and within-herd antibody-prevalence

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2014-01-01

    Detection of bulk tank milk (BTM) antibodies using ELISA (BTM-ELISA) may constitute an inexpensive test for surveillance of Mycobacterium avium subsp. paratuberculosis (MAP) infection in dairy cattle herds provided that the test is accurate and consistent. The objectives of this study were...... Danish Holstein herds over a period of one year. All samples were tested using a commercial indirect ELISA for detection of MAP specific antibodies. The individual cow's results were dichotomised and used to estimate the within-herd antibody prevalence at each test-date. These prevalences were...... to 0.60 when corrected for the within-herd antibody prevalence. Although the test-results were relatively consistent and correlated with the within-herd prevalence, the magnitude of the test-values makes it difficult to use the BTM-ELISA for surveillance of MAP infections in practice....

  17. A liquid phase blocking ELISA for the detection of antibodies against infectious bronchitis virus

    Directory of Open Access Journals (Sweden)

    Cardoso T.C.

    1999-01-01

    Full Text Available A liquid phase blocking ELISA (LPB-ELISA was developed for the detection and measurement of antibodies against infectious bronchitis virus (IBV. The purified and nonpurified virus used as antigen, the capture and detector antibodies, and the chicken hyperimmune sera were prepared and standardized for this purpose. A total of 156 sera from vaccinated and 100 from specific pathogen-free chickens with no recorded contact with the virus were tested. The respective serum titers obtained in the serum neutralization test (SNT were compared with those obtained in the LPB-ELISA. There was a high correlation (r2 = 0.8926 between the two tests. The LPB-ELISA represents a single test suitable for the rapid detection of antibodies against bronchitis virus in chicken sera, with good sensitivity (88%, specificity (100% and agreement (95.31%.

  18. Development and application of triple antibody sandwich enzyme-linked immunosorbent assays for begomovirus detection using monoclonal antibodies against Tomato yellow leaf curl Thailand virus.

    Science.gov (United States)

    Seepiban, Channarong; Charoenvilaisiri, Saengsoon; Warin, Nuchnard; Bhunchoth, Anjana; Phironrit, Namthip; Phuangrat, Bencharong; Chatchawankanphanich, Orawan; Attathom, Supat; Gajanandana, Oraprapai

    2017-05-30

    Tomato yellow leaf curl Thailand virus, TYLCTHV, is a begomovirus that causes severe losses of tomato crops in Thailand as well as several countries in Southeast and East Asia. The development of monoclonal antibodies (MAbs) and serological methods for detecting TYLCTHV is essential for epidemiological studies and screening for virus-resistant cultivars. The recombinant coat protein (CP) of TYLCTHV was expressed in Escherichia coli and used to generate MAbs against TYLCTHV through hybridoma technology. The MAbs were characterized and optimized to develop triple antibody sandwich enzyme-linked immunosorbent assays (TAS-ELISAs) for begomovirus detection. The efficiency of TAS-ELISAs for begomovirus detection was evaluated with tomato, pepper, eggplant, okra and cucurbit plants collected from several provinces in Thailand. Molecular identification of begomoviruses in these samples was also performed through PCR and DNA sequence analysis of the CP gene. Two MAbs (M1 and D2) were generated and used to develop TAS-ELISAs for begomovirus detection. The results of begomovirus detection in 147 field samples indicated that MAb M1 reacted with 2 begomovirus species, TYLCTHV and Tobacco leaf curl Yunnan virus (TbLCYnV), whereas MAb D2 reacted with 4 begomovirus species, TYLCTHV, TbLCYnV, Tomato leaf curl New Delhi virus (ToLCNDV) and Squash leaf curl China virus (SLCCNV). Phylogenetic analyses of CP amino acid sequences from these begomoviruses revealed that the CP sequences of begomoviruses recognized by the narrow-spectrum MAb M1 were highly conserved, sharing 93% identity with each other but only 72-81% identity with MAb M1-negative begomoviruses. The CP sequences of begomoviruses recognized by the broad-spectrum MAb D2 demonstrated a wider range of amino acid sequence identity, sharing 78-96% identity with each other and 72-91% identity with those that were not detected by MAb D2. TAS-ELISAs using the narrow-specificity MAb M1 proved highly efficient for the detection of

  19. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    Science.gov (United States)

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  20. Evaluation of a blocking ELISA for screening of antibodies against porcine reproductive and respiratory syndrome (PRRS) virus

    DEFF Research Database (Denmark)

    Sørensen, K.J.; Bøtner, Anette; Madsen, E.S.

    1997-01-01

    A blocking Elisa was developed for the detection of antibodies against PRRS virus with a view to satisfying the need for examination of blood samples on a large scale. The test was evaluated in comparison with an indirect Elisa and the immunoperoxidase monolayer assay. The blocking Elisa...... was sensitive and specific. It had a higher capacity and was cheaper to perform than the immunoperoxidase monolayer assay and the indirect Elisa. It was comparable to the immunoperoxidase monolayer assay and better than the indirect Elisa in detecting antibodies formed early after infection, and it was superior...... to both the immunoperoxidase monolayer assay and the indirect Elisa in detecting antibodies at a late stage of infection....

  1. Three-site sandwich radioimmunoassay with monoclonal antibodies for a sensitive determination of human alpha-fetoprotein

    International Nuclear Information System (INIS)

    Nomura, M.; Imai, M.; Takahashi, K.; Kumakura, T.; Tachibana, K.; Aoyagi, S.; Usuda, S.; Nakamura, T.; Miyakawa, Y.; Mayumi, M.

    1983-01-01

    Utilizing monoclonal antibodies against human alpha-fetoprotein, 3 distinct antigenic determinants were identified. These antigenic determinants, provisionally designated a, b and c, were arranged in such a manner that the binding of one determinant with the corresponding antibody did not inhibit, or only barely inhibited the binding of antibodies directed to the other 2 determinants. Monoclonal antibodies with 3 different specificities were, therefore, applied to develop a sandwich-type solid-phase radioimmunoassay of the antigen in which wells were coated with anti-a, and radiolabeled anti-b together with radiolabeled anti-c was employed to detect the bound antigen. The 3-site sandwich radioimmunoassay involving 3 different determinants gave a higher sensitivity than 2-site assays in which only anti-b or anti-c was employed as a radiolabeled reagent, because the radioactivity of the 2 labeled antibodies was added on the antigen bound to immobilized anti-a. (Auth.)

  2. An ELISA-inhibition test using monoclonal antibody for the serology of leprosy

    NARCIS (Netherlands)

    Klatser, P. R.; de Wit, M. Y.; Kolk, A. H.

    1985-01-01

    In this study a mouse monoclonal antibody (47-9) is described, which recognized an epitope on the 36 kD protein antigen of M. leprae. The monoclonal antibody showed specificity for M. leprae. An ELISA-inhibition test based on the competitive inhibition by antibodies from human test sera of the

  3. Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.

    Science.gov (United States)

    Rodbard, D

    1988-10-01

    The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  4. Radioimmunoassays and 2-site immunoradiometric 'sandwich' assays: basic principles

    Energy Technology Data Exchange (ETDEWEB)

    Rodbard, D

    1988-10-01

    The 'sandwich' or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  5. A sandwich immunoassay for human prolyl 4-hydroxylase using monoclonal antibody

    International Nuclear Information System (INIS)

    Yoshida, Shinichi

    1986-01-01

    Monoclonal antibody was used in a sandwich enzyme immunoassay and in a radioimmunoassay for human serum immunoreactive prolyl 4-hydroxylase. The enzyme immunoassay utilized a monoclonal antibody as a solid phase and horseradish peroxidase-labeled rabbit antibody to human prolyl 4-hydroxylase as a conjugate. Sensitivity was 0.1 ng of enzyme per tube. With a conjugate purified by an enzyme-bound affinity column, sensitivity was increased to 0.01 ng per tube, and linearity was obtained between 0.01 to 30 ng per tube. The radioimmunoassay used a 125 I-labeled rabbit antibody (IgG) as the conjugate. Sensitivity of this technique was 0.4 ng of enzyme per tube. (Auth.)

  6. Evaluation of commercial ELISA kits for detection of antibodies against bovine atypical pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Uttenthal, Åse

    A group of emerging bovine pestiviruses becomes a possible threat to Bovine Viral diarrhea virus (BVDV) control and eradication programs in the countries of their origin and in the new continents due to the lack of validated detection methods. The use of ELISA kits may be acheaper, time saving...... and less laborious option allowing screening for antibodies in large populations. Since test specific for emerging and new BVDV strains are still under preparation, the purpose of this work was to evaluate available BVDV antibody ELISA assays for their ability to detect antibodies against Hobi-like viruses....... Analysis of a panel of sera obtained from calves experimentally inoculated with Hobi-like virus (isolated from a calf from Thailand) and BVDV type 1 strain using five different ELISA kits in comparison to neutralization test was performed. The specificity and sensitivity of the tests depended greatly...

  7. Immunoprecipitation techniques and Elisa in the detection of anti-Fonsecaea pedrosoi antibodies in chromoblastomycosis

    Directory of Open Access Journals (Sweden)

    Vidal Mônica Scarpelli Martinelli

    2003-01-01

    Full Text Available Chromoblastomycosis (CBM is a chronic subcutaneous infection caused by several dematiaceous fungi. The most commonly etiological agent found in Brazil is Fonsecaea pedrosoi, which appears as thick walled, brownish colored cells with transverse and longitudinal division in the lesions, called "muriform cells". This disease is found worldwide but countries like Madagascar and Brazil have highest incidence. Diagnosis is made by clinical, direct and histopathologic examination and culture of specimens. Serological tests have been used to identify specific antibodies against Fonsecaea pedrosoi antigens, as well as immunotechniques have been used for CBM serological identification and diagnosis. In the present study double immunodiffusion (DID, counterimmunoelectrophoresis (CIE and immunoenzymatic test (ELISA have been used to evaluate humoral immune response in patients with CBM caused by F. pedrosoi. Metabolic antigen was used for immunoprecipitation tests (DID and CIE while somatic antigen for ELISA. Our results demonstrated 53% sensitivity and 96% specificity for DID, while CIE presented 68% sensitivity and 90.5% specificity. ELISA demonstrated 78% sensibility and 83% specificity. Serological tests can be a useful tool to study different aspects of CBM, such as helping differential diagnosis, when culture of the pathogenic agent is impossible.

  8. Development of monoclonal antibodies to pre-haptoglobin 2 and their use in an enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Flanagan, J J; Arjomandi, A; Delanoy, M L; Du Paty, E; Galea, P; Laune, D; Rieunier, F; Walker, R P; Binder, S R

    2014-04-01

    Haptoglobins (HPs) are alpha 2-globulin proteins that bind free hemoglobin in plasma to prevent oxidative damage. HPs are produced as preproteins that are proteolytically cleaved in the ER into alpha and beta chains prior to forming mature, functional tetramers. Two alleles exist in humans (HP1 and HP2), therefore three genotypes are present in the population, i.e., HP1-1, HP2-1, and HP2-2. A biochemical role for nascent haptoglobin 2 (pre-haptoglobin 2 or pre-HP2) as the only known modulator of intestinal permeability has been established. In addition, elevated levels of serum pre-HP2 have been detected in multiple conditions including celiac disease and type I diabetes, which are believed to result in part through dysregulation of the intestinal barrier. In this study, we report the development of a monoclonal antibody that is specific for pre-HP2 with a binding affinity in the nanomolar range. Additional antibodies with specificities for preHP but not mature haptoglobin were also characterized. A sandwich enzyme-linked immunosorbent assay (ELISA) was established and validated. The ELISA showed high specificity for pre-HP2 even in the presence of excess pre-HP1 or mature haptoglobins, and has excellent linearity and inter- and intra-assay reproducibility with a working range from 3.1ng/mL to 200ng/mL. Testing of sera from 76 healthy patients revealed a non-Gaussian distribution of pre-HP2 levels with a mean concentration of 221.2ng/mL (95% CI: 106.5-335.9ng/mL) and a median value of 23.9ng/mL. Compared to current approaches, this ELISA offers a validated, monoclonal-based method with high sensitivity and specificity for measuring pre-HP2 in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A novel sandwich differential capacitive accelerometer with symmetrical double-sided serpentine beam-mass structure

    International Nuclear Information System (INIS)

    Xiao, D B; Li, Q S; Hou, Z Q; Wang, X H; Chen, Z H; Xia, D W; Wu, X Z

    2016-01-01

    This paper presents a novel differential capacitive silicon micro-accelerometer with symmetrical double-sided serpentine beam-mass sensing structure and glass–silicon–glass sandwich structure. The symmetrical double-sided serpentine beam-mass sensing structure is fabricated with a novel pre-buried mask fabrication technology, which is convenient for manufacturing multi-layer sensors. The glass–silicon–glass sandwich structure is realized by a double anodic bonding process. To solve the problem of the difficulty of leading out signals from the top and bottom layer simultaneously in the sandwich sensors, a silicon pillar structure is designed that is inherently simple and low-cost. The prototype is fabricated and tested. It has low noise performance (the peak to peak value is 40 μg) and μg-level Allan deviation of bias (2.2 μg in 1 h), experimentally demonstrating the effectiveness of the design and the novel fabrication technology. (paper)

  10. A Recombinant Secondary Antibody Mimic as a Target-specific Signal Amplifier and an Antibody Immobilizer in Immunoassays.

    Science.gov (United States)

    Min, Junseon; Song, Eun Kyung; Kim, Hansol; Kim, Kyoung Taek; Park, Tae Joo; Kang, Sebyung

    2016-04-11

    We construct a novel recombinant secondary antibody mimic, GST-ABD, which can bind to the Fc regions of target-bound primary antibodies and acquire multiple HRPs simultaneously. We produce it in tenth of mg quantities with a bacterial overexpression system and simple purification procedures, significantly reducing the manufacturing cost and time without the use of animals. GST-ABD is effectively conjugated with 3 HRPs per molecule on an average and selectively bind to the Fc region of primary antibodies derived from three different species (mouse, rabbit, and rat). HRP-conjugated GST-ABD (HRP-GST-ABD) is successfully used as an alternative to secondary antibodies to amplify target-specific signals in both ELISA and immunohistochemistry regardless of the target molecules and origin of primary antibodies used. GST-ABD also successfully serves as an anchoring adaptor on the surface of GSH-coated plates for immobilizing antigen-capturing antibodies in an orientation-controlled manner for sandwich-type indirect ELISA through simple molecular recognition without any complicated chemical modification.

  11. Evaluation of CSFV Antibody ELISAs for the differentiation of infected from vacci-nated animals

    DEFF Research Database (Denmark)

    Schroeder, Sabine; Blome, Sandra; Koenen, Frank

    countries and out-breaks occurred recently e.g. in Germany, France, Hungary, Romania, Bulgaria, and the Slovak Republic. Preventive vaccination is prohibited within the EU, but emergency vaccination can be part of the strategy in case of a contingency. Using conventional vaccines, differentiation...... of vaccinated from infected animals (DIVA) is not possible. Newly developed modified live marker vaccines allow a DIVA strategy based on the use of enzyme linked immunosorbent assay (ELISA) tests. The aim of this study was to evaluate CSF virus (CSFV) Antibody ELISAs, com-mercially available in Europe......, for their diagnostic sensitivity as well as for their potential in differentiating between infected and marker vaccinated animals. Two newly available ELISAs were included into the tests, the Priocheck® CSFV Erns ELISA, a special DIVA test, and the LDL Pigtype® CSFV Antibody ELISA. An inter-laboratory comparison test...

  12. Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests.

    Science.gov (United States)

    Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene

    2018-01-01

    Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

  13. Comparison of radioimmunoassay and ELISA methods for detection of antibodies to chromatin components

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, E; Cheng, N [North Carolina Univ., Chapel Hill (USA). Dept. of Bacteriology and Immunology

    1983-09-16

    A solid phase radioimmunoassay has been compared with an enzyme-linked immunosorbent assay (ELISA) for efficacy in measuring anti-chromatin antibodies. The low backgrounds achieved with the radioimmunoassay method produced a high signal-to-noise ratio and enabled detection of the human test antiserum at a dilution of 1:102,400. By contrast, the ELISA could detect the same antiserum only at a dilution of 1;3200 and above. The radioimmunoassay was consistently more sensitive than the ELSIA for detection of anti-chromatin antibodies in a number of human and mouse sera and ascites fluid containing a monoclonal antibody. Factors affecting sensitivity in both assays are discussed.

  14. Antibodies to UV irradiated DNA: the monitoring of DNA damage by ELISA and indirect immunofluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Wani, A A; Gibson-D' Ambrosio, R E; D' Ambrosio, S M [Ohio State Univ., Columbus (USA). Dept. of Radiology

    1984-10-01

    The enzyme-linked immunosorbant assay (ELISA) was modified to (1) characterize antibodies raised in rabbits against UV-irradiated single-stranded DNA (UVssDNA) complexed with methylated BSA and (2) directly detect pyrimidine dimers in irradiated DNA. The antisera specifically bound to UVssDNA, UVpoly(dT) and to a limited extent to UVdsDNA and UVpoly(dC). Fifty per cent of the maximum antibody binding was observed at a 1-5000 dilution against UVssDNA. Binding to ssDNA and poly(dT) was observed only at much higher concentrations of antibody, whereas no binding to double stranded DNA (dsDNA) was observed. The extent of binding of the antibody was dependent on the UV dose to DNA and the concentration of antigen immobilized on the plate. The ability of various irradiated molecules, DNA, homopolymers and linkers to act as inhibitors of antibody binding establishes that the antigenic determinants are mainly thymine homodimers with lower affinity for cytosine dimers. Potential usefulness of the antibodies to directly quantitate pyrimidine dimers in cells exposed to UV radiation was determined by indirect immunofluorescence. Flow cytometric analysis of immunostained human lymphocytes irradiated with 254 nm radiation indicated that greater than 50% of the population had significantly higher fluorescent intensity than unirradiated cells.

  15. Evaluation of antigen and antibody ELISA's for epidemiological surveys of tsetse-transmitted trypanosomosis in cattle

    International Nuclear Information System (INIS)

    Eisler, M.C.; Hopkins, J.S.; Machila, N.; Bossche, P. van den; Peregrine, A.S.; Luckins, A.G.

    2000-01-01

    Sensitivity and specificity of the FAO/IAEA antigen-detection enzyme-linked immunosorbent assay (ELISA) kits for diagnosis of bovine trypanosomosis were investigated using sera from experimental cattle infected by tsetse challenge with cloned populations of Trypanosoma congolense (3 populations) or T. vivax (1 population). The kits are based on monoclonal antibodies that recognise internal antigens of tsetse-transmitted trypanosomes. Ten cattle were infected with each trypanosome population for at least 60 days, and in combination with uninfected cohorts (n=16) were used in a double-blind study design. Sensitivity and specificity of the tests depended on the choice of positive-negative thresholds expressed as percent positivity with respect to the median OD of 4 replicates of the strong positive reference serum provided with the kit. In general, while overall specificities were high, sensitivities of the antigen-ELISA's were poor. For example, at a cut-off of 5% positivity, the sensitivities of the antigen-ELISA's were 11% for samples (n=1162) from T. congolense infected cattle (n=30), and 24% for samples (n=283) from T. vivax infected cattle (n=10). The corresponding specificity values were 95% and 79%, respectively. There were no values of the positive-negative threshold at which both sensitivity and specificity were satisfactory. Trypanosome species-specificities of the antigen-ELISA's were also poor. Sensitivity and species-specificity of the antigen-ELISA for T. brucei infections were not investigated. The indirect ELISA for the detection of anti-trypanosomal antibodies in bovine serum was adapted for use with dried blood spots on filter paper, and standardised using a strong positive reference serum and the percent positivity system of data expression. The antibody-ELISA was evaluated in Zambia for use in epidemiological surveys of the prevalence of tsetse-transmitted bovine trypanosomosis. Known negative samples (sera, n=209; blood spots, n=466) were

  16. Capture ELISA for IgM antibodies against Plasmodium falciparum glutamate rich protein

    DEFF Research Database (Denmark)

    Dziegiel, M; Borre, Mette; Petersen, E

    1992-01-01

    This report describes a novel mu chain capture ELISA for the detection of IgM antibodies against a Plasmodium falciparum antigen. A fragment of the 220 kDa P. falciparum glutamate rich protein containing amino acid residues 489-1271 was expressed in E. coli as a recombinant chimeric beta-galactos......This report describes a novel mu chain capture ELISA for the detection of IgM antibodies against a Plasmodium falciparum antigen. A fragment of the 220 kDa P. falciparum glutamate rich protein containing amino acid residues 489-1271 was expressed in E. coli as a recombinant chimeric beta...

  17. ELISA for complexes between urokinase-type plasminogen activator and its receptor in lung cancer tissue extracts

    DEFF Research Database (Denmark)

    de Witte, H; Pappot, H; Brünner, N

    1997-01-01

    A sandwich-type ELISA has been developed for the assessment of complexes between urokinase-type plasminogen activator (uPA) and its receptor (uPAR) in extracts of squamous cell lung carcinomas. The assay is based on a combination of rabbit polyclonal anti-uPA antibodies and a biotinylated mouse...... anti-uPAR monoclonal antibody (MAb). The detection limit of the assay is approximately 0.5 fmol/ml. A linear dose-response is obtained with up to 40 fmol/ml of uPA:uPAR complexes, while uPA and uPAR separately do not cause any response in the ELISA. A buffer which has been used previously for optimal...... extraction of uPAR yields the highest amounts of uPA:uPAR complexes. Absorption of tumor extracts with anti-uPA or anti-uPAR MAbs results in a complete disappearance of the ELISA signal, demonstrating the specificity of the ELISA. The recovery of chemically cross-linked uPA:uPAR complexes added to tumor...

  18. Sensitive radioimmunosorbent assay for the detection of plant viruses. [Cauliflower mosaic virus, lettuce mosaic virus

    Energy Technology Data Exchange (ETDEWEB)

    Ghabrial, S A; Shepherd, R J [Kentucky Univ., Lexington (USA); California Univ., Davis (USA))

    1980-06-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that /sup 125/I-labelled ..gamma..-globulin is substituted for the ..gamma..-globulin enzyme conjugate; the bound /sup 125/I-..gamma..-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable.

  19. A sensitive radioimmunosorbent assay for the detection of plant viruses

    International Nuclear Information System (INIS)

    Ghabrial, S.A.; Shepherd, R.J.

    1980-01-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that 125 I-labelled γ-globulin is substituted for the γ-globulin enzyme conjugate; the bound 125 I-γ-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable. (author)

  20. The time course of the specific antibody response by various ELISAs in pigs experimentally infected with Toxoplasma gondii

    DEFF Research Database (Denmark)

    Lind, Peter; Haugegaard, J.; Wingstrand, Anne

    1997-01-01

    With the aim of developing routine serological tests for monitoring the Toxoplasma infection status of Danish swine herds, four ELISAs based on tachyzoite antigen were set up: (1) an indirect ELISA for IgG-antibody; (2) a blocking ELISA for antibody to the membrane antigen, P-30; (3) an indirect ...

  1. An enzyme-linked immunosorbent assay (ELISA) for quantification of mouse surfactant protein D (SP-D)

    DEFF Research Database (Denmark)

    Hansen, Soren; Schmidt, Vivi; Steffensen, Maria Abildgaard

    2008-01-01

    characterized and validated for use in sandwich enzyme-linked immunosorbent assay (ELISA). Based on two of these, we established an ELISA that allows for measurements of mouse SP-D in various body fluids. The final ELISA was optimized and calibrated with a standard of purified recombinant mouse SP-D, which......Surfactant protein D (SP-D) is a pattern recognition molecule of the collectin family of C-type lectins. It is found in the airways and at mucosal surfaces. SP-D is part of the innate immune system where it neutralizes and leads to elimination of microorganisms. It regulates the functions of other...... innate immune cells, such as macrophages and neutrophils. It also modulates the adaptive immune response by interacting with antigen-presenting cells and T cells. Monoclonal anti-mouse-SP-D antibodies were raised from SP-D deficient mice using recombinant SP-D as antigen. Ten monoclonal antibodies were...

  2. Comparative evaluation of antibody positive titer by ELISA and IFA in Theileria annulata vaccinated cattle in Iran

    Directory of Open Access Journals (Sweden)

    Hashemi-Fesharki R.

    2006-03-01

    Full Text Available An enzyme linked immunosorbent assay (ELISA was used to evaluate antibody positive titer in vaccinated and non-vaccinated cattle using schizont infected myeloid cells as an antigen. The result was compared with indirect fluorescent antibody level in the same animals. For this study 116 milking cows, 95 vaccinated and 21 non-vaccinated, were bleeded in order to prepare sera. They were tested with both ELISA and IFA tests. 94 sera had positive antibody titer and 22 sera were negative through ELISA test but, with IFA test, only 89 sera showed positive antibody titer and 27 were negative. Thereby, it was concluded that the sensitivity and specificity of ELISA test in comparison with IFA test was 95.5 % and 66.6 % respectively. This study generally indicated that ELISA could be an effective test for seroepidemiological investigations of bovine tropical theileriosis, and it is considered to be valid as an additional test to distinguish the vaccinated from the non vaccinated cattle in order to schedule vaccination programs.

  3. Monoclonal antibodies to human chorionic gonadotropin and their application to two-site sandwich radioimmunoassay

    International Nuclear Information System (INIS)

    Mizuchi, A.; Iio, M.; Miyachi, Y.

    1984-01-01

    Monoclonal antibodies were prepared against human chorionic gonadotropin (HCG). One monoclonal antibody recognized a conformational determinant expressed only on native HCG molecule and another monoclonal antibody had the specificity for the epitopes located on the β-subunit of HCG. Monoclonal antibodies reacting with different antigenic determinants on the HCG molecule were used to develop a simplified 2-site sandwich radioimmunoassay in which one monoclonal antibody was immobilized and another labeled with 125 iodine. This assay was highly specific for HCG and there was no cross-reactivity with α,β-subunit of HCG, luteinizing hormone and follicle stimulating hormone. (Auth.)

  4. Selectivity verification of cardiac troponin monoclonal antibodies for cardiac troponin detection by using conventional ELISA

    Science.gov (United States)

    Fathil, M. F. M.; Arshad, M. K. Md; Gopinath, Subash C. B.; Adzhri, R.; Ruslinda, A. R.; Hashim, U.

    2017-03-01

    This paper presents preparation and characterization of conventional enzyme-linked immunosorbent assay (ELISA) for cardiac troponin detection to determine the selectivity of the cardiac troponin monoclonal antibodies. Monoclonal antibodies, used to capture and bind the targets in this experiment, are cTnI monoclonal antibody (MAb-cTnI) and cTnT monoclonal antibody (MAb-cTnT), while both cardiac troponin I (cTnI) and T (cTnT) are used as targets. ELISA is performed inside two microtiter plates for MAb-cTnI and MAb-cTnT. For each plate, monoclonal antibodies are tested by various concentrations of cTnI and cTnT ranging from 0-6400 µg/l. The binding selectivity and level of detection between monoclonal antibodies and antigen are determined through visual observation based on the color change inside each well on the plate. ELISA reader is further used to quantitatively measured the optical density of the color changes, thus produced more accurate reading. The results from this experiment are utilized to justify the use of these monoclonal antibodies as bio-receptors for cardiac troponin detection by using field-effect transistor (FET)-based biosensors coupled with substrate-gate in the future.

  5. Procollagen type I N-terminal propeptide (PINP) as an indicator of type I collagen metabolism: ELISA development, reference interval, and hypovitaminosis D induced hyperparathyroidism

    DEFF Research Database (Denmark)

    Orum, O; Hansen, M; Jensen, Charlotte Harken

    1996-01-01

    A sandwich enzyme-linked immunosorbent assay (ELISA) for quantification of the N-terminal propeptide of human procollagen type I (PINP) utilizing purified alpha 1-chain specific rabbit antibodies is described. The ELISA measured the content of the alpha 1-chain of PINP independent of the molecular....../mL, these values being significantly different from the normal range (p ELISA was superior to commercially available assays for PICP and osteocalcin in separation between healthy controls and patients with osteomalaci. Udgivelsesdato: 1996-Aug...

  6. Development, standardisation and validation of ELISA methods to improve the control of trypanosomosis

    International Nuclear Information System (INIS)

    Rebeski, D.E.; Winger, E.M.; Robinson, M.M.; Dwinger, R.H.; Crowther, J.R.

    2000-01-01

    During the period from 1995 to 2000, comprehensive laboratory and field studies on enzyme-linked immunosorbent assay (ELISA) methods for detection of trypanosomal antibodies and antigens were undertaken to improve the proficiency of diagnostic laboratories involved in control of trypanosomosis in the tropics. The work was initiated by the FAO/IAEA through the Coordinated Research Programme D3.20.13 and undertaken in close collaboration with Research Agreement Holders and Research Contract Holders. Initially, the CRP facilitated the field evaluation of three direct sandwich antigen detection ELISAs based on monoclonal antibodies. Diagnostic laboratories were supported with ELISA equipment, disposables, and training. ELISA reagents were produced in sufficient quantities and distributed in a standardised kit format. As a result of the laboratory and field evaluation studies, the assays were found unreliable for trypanosomosis control and rejected for routine use in diagnostic laboratories. At that time, no standardised ELISA system was available for trypanosomosis that was considered suitable for distribution and use under tropical conditions. Through the CRP, a new generation of standardised antibody ELISAs were developed and established using a novel approach, namely the use of antigen-precoated ELISA plates. In addition, the potential of native and denatured trypanosomal antigens as diagnostic candidates was examined. In-house and field evaluation studies in the tropics demonstrated that a reasonable robustness with an acceptable diagnostic assay proficiency was achieved by means of utilising plates precoated with denatured antigens. Moreover, a data charting method for continuous monitoring of the operational performance of the ELISAs was developed and established. It was routinely used as remote control and follow up tool saving the need for costly expert missions to the diagnostic laboratories during the assay validation period. In parallel, preliminary studies

  7. Fundamental study on reactivities of gluten protein types from wheat, rye and barley with five sandwich ELISA test kits.

    Science.gov (United States)

    Lexhaller, Barbara; Tompos, Christine; Scherf, Katharina Anne

    2017-12-15

    Monitoring the compliance of gluten-free foods to the regulatory threshold of 20mg/kg of gluten is essential for celiac disease patients. The different enzyme-linked immunosorbent assays (ELISAs) for gluten detection each have specific characteristics, but there are only a few systematic comparisons. This fundamental study compared the specificities and sensitivities of the R5, G12 and Skerritt monoclonal and two polyclonal antibodies to well-defined gluten protein types (GPT) isolated from wheat, rye and barley flours. Quantitation of protein concentrations by reversed-phase high-performance liquid chromatography provided independent reference values. The ELISA responses showed high variability depending on the type of cereal, the GPT and the antibody used. Overall, ω1,2-gliadins and γ-75k-secalins were most reactive, whereas ω5-gliadins and γ-, B- and D-hordeins were detected with the lowest sensitivities. These results revealed which GPT each antibody is most sensitive to and provided novel insights that will be helpful for appropriate calibration of ELISAs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. A monoclonal antibody to inclusion body disease of cranes virus enabling specific immunohistochemistry and competitive ELISA

    Science.gov (United States)

    Letchworth, G.J.; Fishel, J.R.; Hansen, W.R.

    1997-01-01

    Inclusion body disease of cranes (IBDC) herpesvirus kills some infected cranes and persists in convalescent animals. To enable further study and rapid identification of carrier animals, we developed a monoclonal antibody (MAb) to IBDC virus and used it in immunohistochemistry and a competitive enzyme-linked immunosorbent assay (ELISA). We used conventional techniques to make murine MAbs directed against IBDC virus purified from infected duck embryo cells. Hybridomas reacting in an ELISA with IBDC virus but not uninfected duck embryo cells were characterized by radioimmunoprecipitation, in situ immunohistochemistry, and competitive ELISA with neutralizing and nonneutralizing crane sera. MAb 2C11 immunoprecipitated 59-, 61-, and 110-kD proteins from IBDC virus-infected but not uninfected cells and stained glutaraldehyde-fixed IBDC virus plaques but not surrounding uninfected duck embryo cells in vitro. Antibody 2C11 did not react with duck embryo cells infected with falcon herpesvirus, psittacine herpesvirus, infectious laryngotracheitis, pigeon herpesvirus, or duck plague virus. A competitive ELISA using antibody 2C11 identified most sera that were positive in the neutralization test. This antibody will be useful in further characterizing IBDC virus, its pathogenesis, and its natural history.

  9. Comparative Diagnosis of Serum IgG1 and Coproantigen ELISA for Fasciolosis Detection of Goats in Mexico

    Science.gov (United States)

    Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José

    2016-01-01

    The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans. PMID:27563665

  10. Aqueous two-phase system patterning of detection antibody solutions for cross-reaction-free multiplex ELISA

    Science.gov (United States)

    Frampton, John P.; White, Joshua B.; Simon, Arlyne B.; Tsuei, Michael; Paczesny, Sophie; Takayama, Shuichi

    2014-05-01

    Accurate disease diagnosis, patient stratification and biomarker validation require the analysis of multiple biomarkers. This paper describes cross-reactivity-free multiplexing of enzyme-linked immunosorbent assays (ELISAs) using aqueous two-phase systems (ATPSs) to confine detection antibodies at specific locations in fully aqueous environments. Antibody cross-reactions are eliminated because the detection antibody solutions are co-localized only to corresponding surface-immobilized capture antibody spots. This multiplexing technique is validated using plasma samples from allogeneic bone marrow recipients. Patients with acute graft versus host disease (GVHD), a common and serious condition associated with allogeneic bone marrow transplantation, display higher mean concentrations for four multiplexed biomarkers (HGF, elafin, ST2 and TNFR1) relative to healthy donors and transplant patients without GVHD. The antibody co-localization capability of this technology is particularly useful when using inherently cross-reactive reagents such as polyclonal antibodies, although monoclonal antibody cross-reactivity can also be reduced. Because ATPS-ELISA adapts readily available antibody reagents, plate materials and detection instruments, it should be easily transferable into other research and clinical settings.

  11. Development of ELISA for the detection of transgenic vegetative insecticidal protein in GM crops/produce.

    Science.gov (United States)

    Kumar, R

    2012-01-11

    In the process of the development of insect-resistant genetically modified (GM) crops and also to evaluate the consistency in the expression of toxin under field conditions, immunological assays are commonly being used. An immunoassay was developed to support the labelling of vegetative insecticidal protein (Vip3A)-based GM produce. The developed ELISA for the measurement of Vip3A is a triple antibody sandwich procedure utilising a polyclonal capture antibody (mouse anti-Vip3A) and a polyclonal detection antibody (rabbit anti-Vip3A) followed by use of a third HRP-conjugated anti-species antibody (goat anti-rabbit IgG). The limit of detection limit of the ELISA assay was 16 ng ml(-1) with a linear quantification range from approximately 31 to 500 ng ml(-1) of Vip3A protein. Furthermore, the assay was in-house validated with GM brinjal samples. The assay was specific, sensitive and reproducible, which can be helpful to detect and track down the spread of unapproved and intentionally/unintentionally released GM produce harbouring Vip protein.

  12. Estimation of serum thyroglobulin using isotopic and non-isotopic methods: a comparison between RIA, IRMA and ELISA

    International Nuclear Information System (INIS)

    Ajay Kumar; Velumani, A.; Dandekar, S.R.; Shah, D.H.; Rajashekharrao, B.

    1997-01-01

    Three in-house immunoassays viz, RIA, IRMA and ELISA for estimation of serum Tg were compared for their assay characteristics and clinical utility. The inter- and intra-assay coefficient of variations of RIA and IRMA were comparable and were marginally better than that of ELISA. The sensitivity of IRMA was superior to RIA which in turn was superior than ELISA. Incubation time for both IRMA and ELISA was 4 h as compared to 90 h required for RIA. The enzyme conjugated antibody had longest shelf-life (9 months) followed by radiolabeled antibody (3 months) while radiolabeled Tg had shortest shelf-life (3 weeks). There was no interference from circulating anti-Tg autoantibodies in the RIA of Tg as compared to a gross underestimation observed in both sandwich methods. Assays correlated well with each other (r > 0.85, n=200) and had suitable clinical utility (sensitivity > 93% and specificity > 89%). Each assay though had its own merits and demerits, yet it served the clinical utility for an effective management of patients with differentiated thyroid carcinoma. (author)

  13. Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method

    Science.gov (United States)

    Baker, Harold N.; Murphy, Robin; Lopez, Erica; Garcia, Carlos

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) has long been the primary tool for detection of analytes of interest in biological samples for both life science research and clinical diagnostics. However, ELISA has limitations. It is typically performed in a 96-well microplate, and the wells are coated with capture antibody, requiring a relatively large amount of sample to capture an antigen of interest . The large surface area of the wells and the hydrophobic binding of capture antibody can also lead to non-specific binding and increased background. Additionally, most ELISAs rely upon enzyme-mediated amplification of signal in order to achieve reasonable sensitivity. Such amplification is not always linear and can thus skew results. In the past 15 years, a new technology has emerged that offers the benefits of the ELISA, but also enables higher throughput, increased flexibility, reduced sample volume, and lower cost, with a similar workflow 1, 2. Luminex xMAP Technology is a microsphere (bead) array platform enabling both monoplex and multiplex assays that can be applied to both protein and nucleic acid applications 3-5. The beads have the capture antibody covalently immobilized on a smaller surface area, requiring less capture antibody and smaller sample volumes, compared to ELISA, and non-specific binding is significantly reduced. Smaller sample volumes are important when working with limiting samples such as cerebrospinal fluid, synovial fluid, etc. 6. Multiplexing the assay further reduces sample volume requirements, enabling multiple results from a single sample. Recent improvements by Luminex include: the new MAGPIX system, a smaller, less expensive, easier-to-use analyzer; Low-Concentration Magnetic MagPlex Microspheres which eliminate the need for expensive filter plates and come in a working concentration better suited for assay development and low-throughput applications; and the xMAP Antibody Coupling (AbC) Kit, which includes a protocol, reagents, and

  14. Validation of an improved anaplasma antibody cELISA kit for detection of anaplasma ovis antibody in domestic sheep at the U.S. Sheep Experiment Station in Dubois, ID

    Science.gov (United States)

    An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...

  15. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  16. COMPARISONS OF ELISA AND WESTERN BLOT ASSAYS FOR DETECTION OF CRYPTOSPORIDIUM ANTIBODY

    Science.gov (United States)

    A seroprevalence survey was conducted using ELISA and Western blot (WB) assays for antibody to three Cryptosporidium antigens on 380 blood donors in Jackson County, Oregon. The purpose was to determine if either assay could detect serological evidence of an outbreak which occurre...

  17. Use of monoclonal antibodies against Hendra and Nipah viruses in an antigen capture ELISA

    Directory of Open Access Journals (Sweden)

    Spiropoulou Christina F

    2010-06-01

    Full Text Available Abstract Background Outbreaks of Hendra (HeV and Nipah (NiV viruses have been reported starting in 1994 and 1998, respectively. Both viruses are capable of causing fatal disease in humans and effecting great economical loss in the livestock industry. Results Through screening of hybridomas derived from mice immunized with γ-irradiated Nipah virus, we identified two secreted antibodies; one reactive with the nucleocapsid (N protein and the other, the phosphoprotein (P of henipaviruses. Epitope mapping and protein sequence alignments between NiV and HeV suggest the last 14 amino acids of the carboxyl terminus of the N protein is the target of the anti-N antibody. The anti-P antibody recognizes an epitope in the amino-terminal half of P protein. These monoclonal antibodies were used to develop two antigen capture ELISAs, one for virus detection and the other for differentiation between NiV and HeV. The lower limit of detection of the capture assay with both monoclonal antibodies was 400 pfu. The anti-N antibody was used to successfully detect NiV in a lung tissue suspension from an infected pig. Conclusion The antigen capture ELISA developed is potentially affordable tool to provide rapid detection and differentiation between the henipaviruses.

  18. Exploiting Nanobodies in the Detection and Quantification of Human Growth Hormone via Phage-Sandwich Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Hossam Murad

    2017-05-01

    Full Text Available BackgroundMonitoring blood levels of human growth hormone (hGH in most children with short stature deficiencies is crucial for taking a decision of treatment with extended course of daily and expensive doses of recombinant hGH (rhGH or Somatropin®. Besides, misusing of rhGH by sportsmen is banned by the World Anti-Doping Agency and thus sensitive GH-detecting methods are highly welcome in this field. Nanobodies are the tiniest antigen-binding entity derived from camel heavy chain antibodies. They were successfully generated against numerous antigens including hormones.MethodsA fully nanobody-based sandwich ELISA method was developed in this work for direct measurement of GH in biological samples.ResultsTwo major characteristics of nanobody were exploited for this goal: the robust and stable structure of the nanobody (NbGH04 used to capture hGH from tested samples, and the great ability of tailoring, enabling the display of the anti-GH detector nanobody (NbGH07 on the tip of M13-phage. Such huge, stable, and easy-to-prepare phage-Nb was used in ELISA to provide an amplified signal. Previously, NbGH04 was retrieved on immobilized hGH by phage display from a wide “immune” cDNA library prepared from a hGH-immunized camel. Here, and in order to assure epitope heterogeneity, NbGH07 was isolated from the same library using NbGH04-captured hGH as bait. Interaction of both nanobodies with hGH was characterized and compared with different anti-GH nanobodies and antibodies. The sensitivity (~0.5 ng/ml and stability of the nanobody-base sandwich ELISA were assessed using rhGH before testing in the quantification of hGH in blood sera and cell culture supernatants.ConclusionIn regard to all advantages of nanobodies; stability, solubility, production affordability in Escherichia coli, and gene tailoring, nanobody-based phage sandwich ELISA developed here would provide a valuable method for hGH detection and quantification.

  19. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  20. Development of a sensitive and specific epitope-blocking ELISA for universal detection of antibodies to human enterovirus 71 strains.

    Directory of Open Access Journals (Sweden)

    Fang He

    Full Text Available BACKGROUND: Human Enterovirus 71 (EV71 is a common cause of hand, foot and mouth disease (HFMD in young children. It is often associated with severe neurological diseases and mortalities in recent outbreaks across the Asia Pacific region. Currently, there is no efficient universal antibody test available to detect EV71 infections. METHODOLOGY/PRINCIPAL FINDING: In the present study, an epitope-blocking ELISA was developed to detect specific antibodies to human EV71 viruses in human or animal sera. The assay relies on a novel monoclonal antibody (Mab 1C6 that specifically binds to capsid proteins in whole EV71 viruses without any cross reaction to any EV71 capsid protein expressed alone. The sensitivity and specificity of the epitope-blocking ELISA for EV71 was evaluated and compared to microneutralization using immunized animal sera to multiple virus genotypes of EV71 and coxsackieviruses. Further, 200 serum sample from human individuals who were potentially infected with EV71 viruses were tested in both the blocking ELISA and microneutralization. Results indicated that antibodies to EV71 were readily detected in immunized animals or human sera by the epitope blocking ELISA whereas specimens with antibodies to other enteroviruses yielded negative results. This assay is not only simpler to perform but also shows higher sensitivity and specificity as compared to microneutralization. CONCLUSION: The epitope-blocking ELISA based on a unique Mab 1C6 provided highly sensitive and 100% specific detection of antibodies to human EV71 viruses in human sera.

  1. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  2. Bayesian estimation of sensitivity and specificity of Coxiella burnetii antibody ELISA tests in bovine blood and milk

    DEFF Research Database (Denmark)

    Paul, Suman; Toft, Nils; Agerholm, Jørgen S.

    2013-01-01

    Serological tests for Coxiella burnetii (the causative agent of Q fever) antibodies are usually based on enzyme linked immunosorbent assay (ELISA) although this method is not thoroughly evaluated. The objective of this study was to determine the sensitivity and specificity of an ELISA for detection...... lactating cows is relatively easy, non-invasive and inexpensive and hence milk ELISA may be a better option for screening lactating cows. But, blood ELISA is an option for screening non-lactating cattle....

  3. Lab-on-chip system combining a microfluidic-ELISA with an array of amorphous silicon photosensors for the detection of celiac disease epitopes

    Directory of Open Access Journals (Sweden)

    Francesca Costantini

    2015-12-01

    Full Text Available This work presents a lab-on-chip system, which combines a glass-polydimethilsiloxane microfluidic network and an array of amorphous silicon photosensors for the diagnosis and follow-up of Celiac disease. The microfluidic chip implements an on-chip enzyme-linked immunosorbent assay (ELISA, relying on a sandwich immunoassay between antibodies against gliadin peptides (GPs and a secondary antibody marked with horseradish peroxidase (Ig-HRP. This enzyme catalyzes a chemiluminescent reaction, whose light intensity is detected by the amorphous silicon photosensors and transduced into an electrical signal that can be processed to recognize the presence of antibodies against GPs in the serum of people affected by Celiac syndrome.The correct operation of the developed lab-on-chip has been demonstrated using rabbit serum in the microfluidic ELISA. In particular, optimizing the dilution factors of both sera and Ig-HRP samples in the flowing solutions, the specific and non-specific antibodies against GPs can be successfully distinguished, showing the suitability of the presented device to effectively screen celiac disease epitopes. Keywords: Lab-on-chip, Celiac disease, Microfluidics, On-chip detection, ELISA, Amorphous silicon photosensors

  4. Clinical evaluation of the Serum CrossLaps One Step ELISA, a new assay measuring the serum concentration of bone-derived degradation products of type I collagen C-telopeptides

    DEFF Research Database (Denmark)

    Christgau, S; Rosenquist, C; Alexandersen, P

    1998-01-01

    The Serum CrossLaps One Step ELISA is a sandwich assay using two monoclonal antibodies specific for a beta-aspartate form of the epitope EKAHDGGR derived from the carboxy-terminal telopeptide region of type I collagen alpha1-chain. Our objective was to assess the clinical value of the Serum Cross...

  5. An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1)

    DEFF Research Database (Denmark)

    Selman, L; Henriksen, M L; Brandt, J

    2012-01-01

    -associated serine protease 1 (MASP-1) and/or MASP-3 in circulation. Mutation in the CL-11 gene was recently associated with the developmental syndrome 3MC. In the present study, we established and thoroughly validated a sandwich enzyme-linked immunosorbent assay (ELISA) based on two different monoclonal antibodies....... The assay is highly sensitive, specific and shows excellent quantitative characteristics such as reproducibility, dilution linearity and recovery (97.7-104%). The working range is 0.15-34 ng/ml. The CL-11 concentration in two CL-11-deficient individuals affected by the 3MC syndrome was determined...... and thawing to a certain extent did not influence the ELISA. This ELISA offers a convenient and reliable method for studying CL-11 levels in relation to a variety of human diseases and syndromes....

  6. Detection and partial molecular characterization of atypical plum pox virus isolates from naturally infected sour cherry.

    Science.gov (United States)

    Chirkov, Sergei; Ivanov, Peter; Sheveleva, Anna

    2013-06-01

    Atypical isolates of plum pox virus (PPV) were discovered in naturally infected sour cherry in urban ornamental plantings in Moscow, Russia. The isolates were detected by polyclonal double antibody sandwich ELISA and RT-PCR using universal primers specific for the 3'-non-coding and coat protein (CP) regions of the genome but failed to be recognized by triple antibody sandwich ELISA with the universal monoclonal antibody 5B and by RT-PCR using primers specific to for PPV strains D, M, C and W. Sequence analysis of the CP genes of nine isolates revealed 99.2-100 % within-group identity and 62-85 % identity to conventional PPV strains. Phylogenetic analysis showed that the atypical isolates represent a group that is distinct from the known PPV strains. Alignment of the N-terminal amino acid sequences of CP demonstrated their close similarity to those of a new tentative PPV strain, CR.

  7. Diagnostic accuracy study of a factor VIII ELISA for detection of factor VIII antibodies in congenital and acquired haemophilia A.

    Science.gov (United States)

    Batty, Paul; Moore, Gary W; Platton, Sean; Maloney, James C; Palmer, Ben; Bowles, Louise; Pasi, K John; Rangarajan, Savita; Hart, Daniel P

    2015-10-01

    Antibody formation to factor VIII (FVIII) remains the greatest clinical and diagnostic challenge to the haemophilia-treating physician. Current guidance for testing for inhibitory FVIII antibodies (inhibitors) recommends the functional Nijmegen-Bethesda assay (NBA). A FVIII ELISA offers a complementary, immunological approach for FVIII antibody testing. It was the aim of this study to retrospectively evaluate the performance of a FVIII ELISA (index) for detection of FVIII antibodies, compared with the NBA (reference). All samples sent for routine FVIII antibody testing at two haemophilia Comprehensive Care Centres, were tested in parallel using the NBA and a solid-phase, indirect FVIII ELISA kit (Immucor). A total of 497 samples from 239 patients (severe haemophilia A=140, non-severe haemophilia A=85, acquired haemophilia A=14) were available for analysis. Sixty-three samples tested positive by the NBA (prevalence 12.7%, 95% confidence interval [CI], 9.9-15.9 %), with a median inhibitor titre of 1.2 BU/ml (range 0.7-978.0). The FVIII ELISA demonstrated a specificity of 94.0% (95%CI, 91.3-96.0), sensitivity of 77.8% (95%CI, 65.5-87.3), negative predictive value of 96.7% (95%CI, 94.5-98.2), positive predictive value 65.3% (95%CI, 53.5-76.0), negative likelihood ratio 0.2 (95%CI, 0.1-0.4), positive likelihood ratio 13.0 (95%CI, 8.7-19.3) and a diagnostic odds ratio of 54.9 (95%CI, 27.0-112.0). Strong positive correlation (r=0.77, pNBA (log adjusted) and FVIII ELISA optical density. In conclusion, FVIII ELISA offers a simple, specific, surveillance method enabling batch testing of non-urgent samples for the presence of FVIII antibodies.

  8. Development of a blocking ELISA for detection of Mycoplasma hyopneumoniae infection based on a monoclonal antibody against protein P65.

    Science.gov (United States)

    Liu, Maojun; DU, Gaimei; Zhang, Yue; Wu, Yuzi; Wang, Haiyan; Li, Bin; Bai, Yun; Feng, Zhixin; Xiong, Qiyan; Bai, Fangfang; Browning, Glenn F; Shao, Guoqing

    2016-09-01

    Mycoplasma hyopneumoniae causes porcine enzootic pneumonia, an economically important disease of swine. A more sensitive and reliable method for detection of serum antibodies is needed for epidemiological investigations and to evaluate the effect of immunization. We expressed the M. hyopneumoniae protein P65 in Escherichia coli and produced a monoclonal antibody (mAb) that bound specifically to recombinant P65. Using this mAb, a blocking enzyme linked immunosorbent assay (ELISA) was developed. The blocking ELISA had similar specificity to and sensitivity with the commercial ELISA produced by IDEXX. Thus, this blocking ELISA is a useful test for serological confirmation of M. hyopneumoniae infection.

  9. Distribution and molecular detection of apple mosaic virus in apple ...

    African Journals Online (AJOL)

    ... pair for real time polymerase chain reaction (RT-PCR) detection of coat protein gene for Turkish ApMV isolates. Apple mosaic virus isolates were collected in 2007 to 2010 and the presence of the pathogen was detected by double antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA) and RT-PCR tests.

  10. Equal intensity double plasmon resonance of bimetallic quasi-nanocomposites based on sandwich geometry

    Energy Technology Data Exchange (ETDEWEB)

    Chakravadhanula, V S K; Elbahri, M; Schuermann, U; Takele, H; Greve, H; Zaporojtchenko, V; Faupel, F [Chair for Multicomponent Materials, Technical Faculty of the CAU Kiel, Kaiserstrasse 2, D-24143 Kiel (Germany)], E-mail: ff@tf.uni-kiel.de

    2008-06-04

    We report a strategy to achieve a material showing equal intensity double plasmon resonance (EIDPR) based on sandwich geometry. We studied the interaction between localized plasmon resonances associated with different metal clusters (Au/Ag) on Teflon AF (TAF) in sandwich geometry. Engineering the EIDPR was done by tailoring the amount of Au/Ag and changing the TAF thickness. The samples were investigated by transmission electron microscopy (TEM) and UV-visible spectroscopy. Interestingly, and in agreement with the dipole-surface interaction, the critical barrier thickness for an optimum EIDPR was observed at 3.3 nm. The results clearly show a plasmon sequence effect and visualize the role of plasmon decay.

  11. USE OF AN INDIRECT ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA TO DETECT ANTIBODIES IN AYU (Plecogiossus altivelis VACCINATED BY IMMERSION ADMINISTRATION

    Directory of Open Access Journals (Sweden)

    . Sukenda

    2007-05-01

    Full Text Available ABSTRACTAn indirect enzyme-linked immunosorbent assay (ELISA was used to detect serum antibody in ayu, Plecoglossus altivelis, immunized against Pseudomonasplecoglossicida by immersion vaccination.  First, the procedure of the ELISA was optimized and the sensitivity was checked.  Secondly, the formalin-killed cells (FKC of P. plecoglossicida was administered to ayu by immersion vaccination.  Two weeks after vaccination, fish were divided into two groups, one group was given booster.  The level of specific antibody production of both boostered and vaccinated only fish were statistically higher than unvaccinated control fish at the time of each blood collection.  However, the differences between the boostered and vaccinated only fish were not statistically significant.Keywords :  immunization, Pseudomonas plecoglossicida, ayu, ELISA ABSTRAKIndirect enzyme-linked immunosorbent assay (ELISA digunakan untuk mendeteksi antibodi pada ayu, Plecoglossus altivelis, yang diimunisasi dengan cara perendaman untuk melawan infeksi Pseudomonas plecoglossicida.  Pertama, prosedur ELISA dioptimasikan dan sensitivitas dari metode ini juga diperiksa.  Kemudian, bakteri Plecoglossus altivelis yang sudah dimatikan dengan formalin diberikan ke ikan ayu dengan vaksinasi perendaman.  Dua minggu setelah vaksinasi, ikan dibagi menjadi dua kelompok, satu kelompok diberi vaksinasi kedua.  Produksi antibodi spesifik dari ikan-ikan yang divaksinasi satu kali dengan vaksinasi dua kaii secara statistik lebih tinggi dibandingkan dengan control.  Akan tetapi, tidak ada perbedaan produksi antibodi antara ikan yarig divaksanisi satu kali dengan divaksinasi dua kali.Kata kunci :  imunisasi, Pseudomonasplecoglossicida, ayu, ELISA

  12. Evaluation of four indirect ELISA systems for the detection of trypanosomal antibodies in bovine serum

    International Nuclear Information System (INIS)

    Ndamkou, C.N.; Yomo, J.P.

    2000-01-01

    Four indirect-ELISA systems developed by the Joint FAO/IAEA Division for the detection of trypanosomal antibodies in bovine serum were evaluated in the field. Internal quality control data obtained were good showing that pre-coating plates with antigen increase the robustness of the assay and contribute to its standardisation. ELISA systems derived from Trypanosoma vivax antigen lysates gave a better performance than ELISA systems using T. congolense antigens. Sensitivity and specificity corresponding to the highest accuracy were 86-87% and 83-85% respectively. When comparing the two ELISA systems utilising T. vivax antigens, there was no significant difference between native and denatured antigens and diagnostic threshold was higher for denatured antigens. (author)

  13. Measurement of anti-Ascaris IgE antibody levels in tropical allergic patients, using modified ELISA.

    Science.gov (United States)

    Lynch, N R; Pérez, M; López, R I; Turner, K J

    1987-01-01

    The two most common situations in which the determination of serum immunoglobulin E (IgE) levels is of interest are allergic disease and helminthic infection. This is of particular importance in the tropical environment, as helminthiasis possibly influences the expression of allergic reactivity. Because of the low absolute serum levels of IgE, solid-phase radioimmunoassay (RIA) is conventionally used for its measurement. The radioactive and toxic volatile reagents required restricted application of such assays in the tropical situation. We evaluated a nitrocellulose-based, avidin biotin-amplified enzyme-linked immunosorbent assay (ELISA) for IgE, in which monoclonal anti-IgE antibodies were employed. Excellent correlations were obtained between ELISA and RIA for both total and allergen-specific IgE measurement. The ELISA was then applied to determine the levels of anti-Ascaris antibodies in selected allergic patients, in whom no cutaneous immediate hypersensitivity reactions were demonstrated against common environmental allergens such as house dust, but who had positive skin reactions to Ascaris extract. When compared with non-allergic subjects who had equivalent cutaneous reactivity, no significant differences were found in total IgE levels, house-dust specific IgE levels or non-reaginic anti-Ascaris antibody levels. However, higher levels of IgE antibody against the parasite were detected in the allergic subjects. This observation raises the question of the possible role of Ascaris infection in the stimulation of allergic reactions in such patients. We describe an immunoenzymatic assay for total and specific IgE antibody that is better adapted to the tropical situation than the commonly used radioimmunoassays.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Preparation of recombinant coat protein of Prunus necrotic ringspot virus.

    Science.gov (United States)

    Petrzik, K; Mráz, I; Kubelková, D

    2001-02-01

    The coat protein (CP) gene of Prunus necrotic ringspot virus (PNRSV) was cloned into pET 16b vector and expressed in Escherichia coli. CP-enriched fractions were prepared from whole cell lysate by differential centrifugation. The fraction sedimenting at 20,000 x g for 30 mins was used for preparation of a rabbit antiserum to CP. This antiserum had a titer of 1:2048 and reacted in a double-antibody sandwich ELISA (DAS-ELISA).

  15. Development and Evaluation of a Novel ELISA for Detection of Antibodies against HTLV-I Using Chimeric Peptides.

    Science.gov (United States)

    Mosadeghi, Parvin; Heydari-Zarnagh, Hafez

    2018-04-01

    We aimed to develope a peptide-based indirect ELISA to detect antibodies against Human T-lymphotropic virus type I (HTLV-I). Two chimeric peptides (CP-1 and CP-2) were designed using linear immunodominant epitopes of gp-46-I, and gp21-I proteins, according to the sequence from Uniprot database. These peptides were studied initially in the ELISA using infected sera. The most promising peptideCP-1, was used to develop a peptide ELISA for detection of HTLV-I infected sera. The optimal conditions for CP-1ELISA were: the optimum coating buffer was 100mM NaHCO3, pH 9.6; coating peptide concentration was 10 µg/mL; the optimal blocking buffer was5% fetal bovine serum (FBS); the secondary antibody concentration was 1:2000; and serum dilution was 1:20. 20serum samples from HTLV-I infected patients were evaluated by ELISA developed. CP-1 showed high antigenicity while lacking any cross-reactivity with normal human sera. The results of evaluations indicated that in comparison with commercial ELISA, CP-1 ELISA showed good sensitivity and specificity. With further validation, CP-1as described in the present study could be introduced as novel reliable and cost-effective candidates for the high-specific screening of HTLV-I/-II infections in endemic regions.

  16. Quantitation of antibodies to nucleoribonucleoprotein by ELISA : relation between antibody levels and disease activity in patients with connective tissue disease

    NARCIS (Netherlands)

    Houtman, PM; Kallenberg, CGM; Limburg, PC; Huitema, MG; van Rijswijk, MH; The, TH

    1985-01-01

    We describe a solid-phase enzyme-linked immunosorbent assay (ELISA) for quantitation of antibodies to nucleoribonucleoprotein (nRNP/Sm). nRNP/Sm was purified from rabbit thymus acetone powder by immunoaffinity chromatography and characterized by counterimmunoelectrophoresis (CIE) and immunoblotting

  17. A Monoclonal Antibody-Based ELISA for Multiresidue Determination of Avermectins in Milk

    Directory of Open Access Journals (Sweden)

    Wenxiao Jiang

    2012-06-01

    Full Text Available Due to the widespread use and potential toxicity of avermectins (AVMs, multi-residue monitoring of AVMs in edible tissues, especially in milk, has become increasingly important. With the aim of developing a broad-selective immunoassay for AVMs, a broad-specific monoclonal antibody (Mab was raised. Based on this Mab, a homologous indirect enzyme-linked immunosorbent assay (ELISA for the rapid detection of AVMs in milk was developed. Under the optimized conditions, the IC50 values in assay buffer were estimated to be 3.05 ng/mL for abamectin, 13.10 ng/mL for ivermectin, 38.96 ng/mL for eprinomectin, 61.00 ng/mL for doramectin, 14.38 ng/mL for emamectin benzoate. Detection capability (CCβ of the ELISA was less than 5 ng/mL and 2 ng/mL in milk samples prepared by simple dilution and solvent extraction, respectively. The optimized ELISA was used to quantify AVMs in milk samples spiked at different amounts. The mean recovery and coefficient of variation (CV were 95.90% and 15.42%, respectively. The Mab-based ELISA achieved a great improvement in AVMs detection. Results proved this broad-selective ELISA would be useful for the multi-residue determination of AVMs in milk without purification process.

  18. Two-monoclonal-antibody sandwich-type assay for thyrotropin, with use of an avidin-biotin separation technique

    International Nuclear Information System (INIS)

    Odell, W.D.; Griffin, J.; Zahradnik, R.

    1986-01-01

    We have developed a sensitive, specific, noncompetitive, sandwich-type radioimmunoassay for human thyrotropin (hTSH), which can be performed in 30 min. The assay involves two monoclonal antibodies, selected for high affinity and specificity and also for reaction against antigenic sites on hTSH that are distal from each other. One of these antibodies is labeled with 125 I; the other is conjugated covalently to biotin. Polystyrene beads were also conjugated covalently to biotin. After conjugation, the beads were incubated with avidin. These beads represent a rapid, simple method for separating hTSH-bound antibody from free antibody. The biotin-antibody-hTSH- 125 I-labeled antibody complexes bind to the beads and hTSH concentration is directly related to counts per minute. This assay can detect hTSH at a concentration of 0.06 milli-unit/L in serum

  19. [Study of anti-idiotype antibodies to human monoclonal antibody].

    Science.gov (United States)

    Harada, R; Takahashi, N; Owaki, I; Kannagi, R; Endo, N; Morita, N; Inoue, M

    1992-02-01

    A human monoclonal antibody, ll-50 (IgM, lambda), was generated, which reacted specifically with a major of glycolipid present in LS174T colon cancer cells. The glycolipid antigen which reacted with the ll-50 antibody was expected to four sugar residues from its TLC mobility, and it was ascertained that the glycolipid antigen which reacted with ll-50 antibody might be Lc4 antigen [Gal beta 1----3 GLcNAc beta 1----3 Gal beta 1----4 Glc beta 1----1 Cer] judging from TLC immunostaining and ELISA when the reactivity of ll-50 antibody was tested using various pure glycolipids in 3-5 sugar residues as an antigen. Sera in patients with malignant disorders and healthy individuals were analyzed by Sandwich assay of immobilized and biotinylated ll-50 antibody. The serum of the Lc4 antigen recognized by ll-50 antibody was significantly higher in patients with malignant disorders than that in healthy individuals (p less than 0.05). Three mouse monoclonal anti-idiotype antibodies, G3, B3 and C5 (all IgG1), were generated by the immunization of BALB/c mice with ll-50 antibody. These anti-idiotype antibodies specifically bound to to human monoclonal antibody, ll-50 and had a significant inhibitory activity towards the binding of ll-50 antibody to the Lc4 antigen. This indicated that these anti-idiotype antibodies, G3, B3, and C5, were paratope-related anti-idiotype antibodies. G3, B3, and C5 were expected to define the nearest idiotope because they could mutually inhibit ll-50 antibody. Sera in patients with malignant disorders and healthy individuals were analyzed by Sandwich assay of immobilized and biotinylated anti-idiotype antibodies, G3, B3, and C5. As to the ll-50 like antibodies defined by C5 (Id-C5+), the mean serum level in patients with malignant disorders was significantly higher than that in healthy individuals (p less than 0.05). As to the ll-50 like antibodies defined by B3 (Id-B3+), the mean serum level in patients with malignant disorders was significantly higher

  20. An ELISA to Detect Serum Antibodies to the Salivary Gland Toxin of Ixodes holocyclus Neumann in Dogs and Rodents

    Directory of Open Access Journals (Sweden)

    S. Hall-Mendelin

    2011-01-01

    Full Text Available The Ixodes holocyclus tick causes paralysis in up to 10,000 companion and domestic animals each year in Australia. Treatment requires the removal of the parasite and the administration of a commercial tick antiserum that is prepared from hyperimmune dogs. Each batch of this serum is initially tested for toxin-neutralising potency in a mouse bioassay that is expensive, time consuming, and subjective. With the aim of developing a rapid in vitro assay to replace the bioassay, we used a partially purified antigen prepared from I. holocyclus salivary glands to develop an ELISA to detect toxin-reactive antibodies in hyperimmune dog sera. The optimised ELISA reliably detected antibodies reactive to I. holocyclus salivary gland antigens. Parallel testing of sera with a negative control antigen prepared from the salivary glands of the nontoxic tick Rhipicephalus (Boophilus microplus provided further evidence that we were detecting toxin-specific antibodies in the assay. Using the ELISA, we could also detect antibodies induced in rats after experimental infestation with I. holocyclus. This assay shows promise as an alternative means of assessing the potency of batches of hyperimmune dog serum and to screen for toxin-reactive monoclonal antibodies produced from immunised rodents.

  1. ELISA for detection of variant rabbit haemorrhagic disease virus RHDV2 antigen in liver extracts.

    Science.gov (United States)

    Dalton, K P; Podadera, A; Granda, V; Nicieza, I; Del Llano, D; González, R; de Los Toyos, J R; García Ocaña, M; Vázquez, F; Martín Alonso, J M; Prieto, J M; Parra, F; Casais, R

    2018-01-01

    The emergence and rapid spread of variant of the rabbit hemorrhagic disease virus (RHDV2) require new diagnostic tools to ensure that efficient control measures are adopted. In the present study, a specific sandwich enzyme-linked immunosorbent assay (ELISA) for detection of RHDV2 antigens in rabbit liver homogenates, based on the use of an RHDV2-specific monoclonal antibody (Mab) 2D9 for antigen capture and an anti-RHDV2 goat polyclonal antibody (Pab), was developed. This ELISA was able to successfully detect RHDV2 and RHDV2 recombinant virions with high sensitivity (100%) and specificity (97.22%). No cross-reactions were detected with RHDV G1 viruses while low cross-reactivity was detected with one of the RHDVa samples analyzed. The ELISA afforded good repeatability and had high analytical sensitivity as it was able to detect a dilution 1:163,640 (6.10ng/mL) of purified RHDV-N11 VLPs, which contained approximately 3.4×10 8 molecules/mL particles. The reliable discrimination between closely related viruses is crucial to understand the epidemiology and the interaction of co-existing pathogens. In the work described here we design and validate an ELISA for laboratory based, specific, sensitive and reliable detection of RHDVb/RHDV2. This ELISA is a valuable, specific virological tool for monitoring virus circulation, which will permit a better control of this disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J

    2017-11-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.

  3. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  4. [Effect comparison between two ELISA kits in IgG antibody detection of Echinococcus granulosus].

    Science.gov (United States)

    Chu, Yan-Hong; Cai, Yu-Chun; Ai, Lin; Lu, Yan; Zhang, Jia; Chen, Jia-Xu

    2013-06-01

    To compare the effects of two ELISA kits on IgG antibody detection of human Echinococcus granulosus. A Total of 134 sera of patients with echinococcosis, paragonimiasis westermani, clonorchiasis sinensis, schistosomiasis japonica, and cysticercosis cellulosae, and normal persons were detected by two IgG ELISA kits produced by different companies. Furthermore, the specificity, sensitivity and cross reactivity were counted and analyzed statistically. The sensitivity and specificity were extremely high of the two kits as 100.00%. The cross-reactivity rates were 25.00% (paragonimiasis westermani), 26.09% (clonorchiasis sinensis), 10.00% (schistosomiasis japonica), and 87.5% (cysticercosis), respectively, by using the kit produced by the Combined Company in Shenzhen; the cross-reactivity rates were 5.00% (paragonimiasis westermani), 13.04% (clonorchiasis sinensis), 20.00% (schistosomiasis japonica), and 93.75% (cysticercosis) respectively, by using the kit produced by Haitai Company in Zhuhai. In addition, there was a significant difference of Paragonimus westermani detection (P 0.05) between the two kits. Both ELISA kits on IgG antibody detection of human Echinococcus granulosus have the advantages of a high sensitivity, specificity, convenience and high-speed. However, it is also in urgent need to further solve the cross-reactivity of Echinococcus granulosus with other parasites, in order to improve the accuracy of early diagnosis.

  5. Expression, purification of metallothionein genes from freshwater crab (Sinopotamon yangtsekiense) and development of an anti-metallothionein ELISA

    Science.gov (United States)

    Zhang, Hao; Zhou, Hui

    2017-01-01

    Using the phoA-fusion technology, the recombinant metallothionein (MT) from freshwater crab (Sinopotamon yangtsekiense) has been successfully produced in Escherichia coli. MT purified from the bacterial suspension showed one polypeptide with a molecular weight of 7 kDa by tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis (Tricine-SDS-PAGE). Western-blotting confirmed the polypeptides had a specific reactivity with mouse polyclonal MT anti-serum. Based on the purified MT and MT anti-serum, the reaction parameters for an enzyme-linked immunosorbent assay (ELISA) were developed. The direct coating ELISA showed a higher linear relationship compared to antibody sandwich coating ELISA. The optimal dilution rates of purified MT anti-serum and coating period were shown to be 1:160,000 and 12 hours at 4°C. At 37°C, the appropriate reaction duration of the first antibody and the second antibody were 2 hours and 1 hour, respectively. According to these optimal parameters, the standard linear equation, y = 0.0032x + 0.1769 (R2 = 0.9779, x, y representing MT concentration and OD450 value), was established for the determination of MT concentration with a valid range of 3.9–500 ng/ml. In verification experiments, the mean coefficients of variation of the intra-assay and inter-assay were 3.260% and 3.736%, respectively. According to the result of MT recovery, ELISA with an approaching 100% MT recovery was more reliable and sensitive than the Cd saturation assay. In conclusion, the newly developed ELISA of this study was precise, stable and repeatable, and could be used as a biomarker tool to monitor pollution by heavy metals. PMID:28350826

  6. Detection of NP, N3 and N7 antibodies to avian influenza virus by indirect ELISA using yeast-expressed antigens

    Directory of Open Access Journals (Sweden)

    Ammayappan Arun

    2009-10-01

    Full Text Available Abstract Background Avian influenza viruses, belonging to the family Orthomyxoviridae, possess distinct combinations of hemagglutinin (H and the neuraminidase (N surface glycoproteins. Typing of both H and N antigens is essential for the epidemiological and surveillance studies. Therefore, it is important to find a rapid, sensitive, and specific method for their assay, and ELISA can be useful for this purpose, by using recombinant proteins. Results The nucleoprotein (NP and truncated neuraminidase subtype 3 and 7 of avian influenza virus (AIV were expressed in Saccharomyces cerevisiae and used to develop an indirect enzyme-linked immunosorbent assay for antibody detection. The developed assays were evaluated with a panel of 64 chicken serum samples. The performance of NP-ELISA was compared with the commercially available ProFlok® AIV ELISA kit. The results showed comparable agreement and sensitivity between the two tests, indicating that NP-ELISA assay can be used for screening the influenza type A antibody in AIV infected birds. The N3 and N7- ELISAs also reacted specifically to their type specific sera and did not exhibit any cross-reaction with heterologous neuraminidase subtype specific sera. Conclusion The study demonstrates the expression of the NP, N3, and N7 proteins of AIV in yeast (S. cerevisiae and their application in developing an indirect ELISA for detecting NP, N3 and N7 antibodies from AIV-infected chicken sera. The described indirect ELISAs are rapid, sensitive, specific and can be used as promising tests during serological surveillance.

  7. A murine monoclonal antibody based enzyme-linked immunosorbent assay for almond (Prunus dulcis L.) detection.

    Science.gov (United States)

    Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K

    2013-11-13

    A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (assay variability assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.

  8. Influence of gamma radiation on antibodies fixation on polystyrene. Application to ELISA enzyme immunoassay

    International Nuclear Information System (INIS)

    Esterlin, S.

    1986-01-01

    This thesis is divided into two parts: the first part includes a description of the ELISA test, a comparative analysis of the main supports (polystyrene microtitration trays) used for this technique and an evaluation of gamma radiation effects on the quality of the supports. The study was carried out with the following antigens: Spiroplasma citri R8A2, a tymovirus and Tristeza virus. The second part dealt with the effects of gamma radiations on antibodies and antibody-support system (interaction immobilized immunoglobulins-plastic support) [fr

  9. Synthetic positive controls for ELISA test kits for detection of IgA and IgM antibodies to Chlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    O. Y. Galkin

    2015-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA is the most informative and versatile method of serological diagnostics. The possibility of detecting by ELISA specific antibodies of different classes allow to differentiate primary infectious process and its remission, exacerbation and chronic disease (holding of differential diagnosis. This approach is implemented in the methodology for evaluation of patients for presence of humoral immune response against the causative agent of urogenital chlamydiosis. As with other infections immediately after Chlamydia trachomatis infection the specific IgM antibodies are formed, and subsequently basic projective antibodies of IgG class are synthesized. However, at exacerbation of chronic urogenital chlamydiosis specific IgA antibodies can be synthesized. That is why comprehensive evaluation of patients for presence of humoral immune response to Ch. trachomatis involves plasma testing of specific antibodies of all three classes. The essential problem in the production of ELISA diagnostic kits is obtaining of positive control. The classic version of positive control is human blood plasma containing specific antibodies. But specific IgM- and IgA-positive sera are deficit raw materials. This fact can significantly limit the production of diagnostic kits, especially in case of large-scale manufacture. We have suggested methodological approach to use of synthetic positive controls in indirect ELISA kits based on conjugate of normal human IgM (IgA and monoclonal antibodies against major outer membrane protein of Ch. trachomatis. It was found that it’s possible to realize such task by means of NHS ester-maleimide-mediated conjugation (by sulfosuccinimidyl-4-(N-maleimidomethylcyclohexane-1-carboxylate and reductive amination-mediated conjugation (by sodium periodate. It was found that synthetic positive controls obtained by different methods are characterized by higher titer compared to IgM- and IgA-positive high

  10. Development and characterization of highly informative ELISA for the detection of IgG and IgA antibodies to Сhlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    O. Yu. Galkin

    2018-04-01

    Full Text Available The goal of this work was developing of highly informative an enzyme-linked immunosorbent assay (ELISA for the detection of IgG and IgA antibodies against to Chlamydia trachomatis, as well as comparative characterization of developed assay using standardized control materials. The study was conducted using: monoclonal antibodies (McAbs to human IgA and IgG; recombinant Ch. trachomatis proteins – Pgp3, major outer membrane protein (MOMP; two panels of characterized sera and four reference ELISA kits. The study of immunochemical activity of peroxidase conjugates of McAbs was performed in comparison with conjugates of commercial analogues: anti-IgG McAb 2A11 and anti-IgA McAb AD3. About half of the conjugates from the received McAbs panel were more active compared to the reference antibody conjugates. It was quite justified to use the conjugates of antibodies that interact with different antigenic determinants. When IgG antibodies were detected to MOMP, it was justified 1.14-1.56 times more; when IgA antibodies were detected to MOMP, it was justified 1.16-1.37 times more. ELISA for detecting IgG/IgA antibodies to MOMP and Pgp3 of Ch. trachomatis were evaluated using appropriately described serum panels OCO-42-28-313-00 and OCO-42-28-314-00. Comparative studies of the developed ELISA for the detection of IgG and IgA antibodies to the MOMP and Pgp3 of Ch. trachomatis showed their prominent advantage over the commercial analogues, which more clearly demonstrates the difference in the ratio of average values of optical density of positive and negative samples of the described panel of sera: this indicator for commercial kits was 1.36-3.59 times less.

  11. Laboratory safe detection of nucleocapsid protein of Rift Valley fever virus in human and animal specimens by a sandwich ELISA.

    Science.gov (United States)

    Jansen van Vuren, P; Paweska, J T

    2009-04-01

    A safe laboratory procedure, based on a sandwich ELISA (sAg-ELISA), was developed and evaluated for the detection of nucleocapsid protein (NP) of Rift Valley fever virus (RVFV) in specimens inactivated at 56 degrees C for 1h in the presence of 0.5% Tween-20 (v/v) before testing. Polyclonal capture and detection immune sera were generated respectively in sheep and rabbits immunized with recombinant NP antigen. The assay was highly repeatable and specific; it detected strains of RVFV from the entire distributional range of the disease, isolated over a period of 53 years; no cross-reactivity with genetically related African phleboviruses or other members of the family Bunyaviridae was observed. In specimens spiked with RVFV, including human and animal sera, homogenates of liver and spleen tissues of domestic ruminants, and Anopheles mosquito homogenates, the sAg-ELISA detection limit ranged from log(10)10(2.2) to 10(3.2) TCID(50)/reaction volume. The ELISA detected NP antigen in spiked bovine and sheep liver homogenates up to at least 8 days of incubation at 37 degrees C whereas infectious virus could not be detected at 48h incubation in these adverse conditions. Compared to virus isolation from sera from RVF patients and sheep infected experimentally, the ELISA had 67.7% and 70% sensitivity, and 97.97% and 100% specificity, respectively. The assay was 100% accurate when testing tissues of various organs from mice infected experimentally and buffalo foetuses infected naturally. The assay was able to detect NP antigen in infective culture supernatants 16-24h before cytopathic effects were observed microscopically and as early as 8h after inoculation with 10(5.8) TCID(50)/ml of RVFV. This ability renders the assay for rapid identification of the virus when its primary isolation is attempted in vitro. As a highly specific, safe and simple assay format, the sAg-ELISA represents a valuable diagnostic tool for use in less equipped laboratories in Africa, and for routine

  12. Sandwich-like graphene/polypyrrole/layered double hydroxide nanowires for high-performance supercapacitors

    Science.gov (United States)

    Li, Xuejin; Zhang, Yu; Xing, Wei; Li, Li; Xue, Qingzhong; Yan, Zifeng

    2016-11-01

    Electrode design in nanoscale is considered to be ultra-important to construct a superb capacitor. Herein, a sandwich-like composite was made by combining graphene/polypyrrole (GPPY) with nickel-aluminum layered double hydroxide nanowires (NiAl-NWs) via a facile hydrothermal method. This sandwich-like architecture is promising in energy storage applications due to three unique features: (1) the conductive GPPY substrate not only effectively prevents the layered double hydroxides species from aggregating, but also considerably facilitates the electron transmission; (2) the ultrathin NiAl-NWs ensure a maximum exposure of active Ni2+, which can improve the efficiency of rapid redox reactions even at high current densities; (3) the sufficient space between anisotropic NiAl-NWs can accommodate a large volume change of the nanowires to avoid their collapse or distortion during the reduplicative redox reactions. Keeping all these unique features in mind, when the as-prepared composite was applied to supercapacitors, it presented an enhanced capacitive performance in terms of high specific capacitance (845 F g-1), excellent rate performance (67% retained at 30 A g-1), remarkable cyclic stability (92% maintained after 5000 cycles) and large energy density (40.1 Wh·Kg-1). This accomplishment in the present work inspires an innovative strategy of nanoscale electrode design for high-rate performance supercapacitor electrodes containing pseuducapacitive metal oxide.

  13. [Use of monoclonal antibodies against horse immunoglobulin in an enzyme immunoassay of bacterial toxins and anatoxins].

    Science.gov (United States)

    Burkin, M A; Gal'vidis, I A; Iakovleva, I V; Sviridov, V V

    2007-01-01

    Immunization of BALB/c mice by horse antiserum against diphtheria made it possible to obtain IgG1 monoclonal antibodies (MoAbs) 2B7E4 specific for light chains of horse immunoglobulin (Ig). Unlike commercial preparations of anti-horse immunoglobulin antibodies, which are specific for the whole Ig molecule or its Fc-fragment, the peroxidase (HRP) conjugate of the MoAb, 2B7E4-HRP did not interact with human, mouse, rabbit, and sheep Igs, or horse albumin. The conjugate obtained was used with MoAbs against bacterial toxins and commercial horse anatoxins, as a universal reagent in sandwich enzyme immunoassay (ELISA) for bacterial toxins and anatoxins. The detection sensitivity of diphtheria toxin/anatoxin equaled 0.0005 Lf/ml; tetanus toxin and anatoxin were detected with sensitivities of 20 LD50/ml and 0.005 UI/ml, respectively. A similar sandwich ELISA for botulinum anatoxins (group measurement) allowed types A, B, and E to be detected at 0.02, 0.002, and 0.001 UI/ml, respectively; selective measurement was only possible in the case of type E anatoxin (0.001 UI/ml).

  14. Detection of FMD virus type specific IgG1, IgG2 and IgA antibodies in milk and serum of buffaloes vaccinated with oil adjuvanted polyvalent FMD vaccine

    Directory of Open Access Journals (Sweden)

    R. Sharma

    2010-02-01

    Full Text Available The present investigation was carried out on 15 randomly selected milch buffaloes divided into three groups on the basis of lactation at an organized farm, to study the foot and mouth disease virus type specific antibodies in milk and serum following FMD vaccination. Milk and serum samples collected before vaccination i.e. 0 day and on 7, 14, 28, 42 and 56 days post vaccination, were analyzed for the detection of FMD virus specific IgG1, IgG2 and IgA antibody response by indirect double antibody sandwich ELISA. Significant FMD virus type specific antibody titres (IgG1, IgG2 and IgA were detected in milk and serum of buffaloes on different days post vaccination, though the levels of antibodies were lower in milk as compared to serum. FMD virus type specific IgG1 was found to be the predominant subclass as compared to IgG2 and IgA both in milk and serum of vaccinated buffaloes. Milk and serum IgG1, IgG2 and IgA antibody titres were positively correlated with values of regression coefficient (R as 0.506, 0.434 and 0.396, respectively.

  15. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    International Nuclear Information System (INIS)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong; Shi, Hanchang; Long, Feng

    2016-01-01

    . - Highlights: • Sandwich-like immunoassay strategy was used for rapid detection of small molecule. • Optofluidic sensing platform investigated the sandwich-like immunoassay mechanism. • A versatile optical biosensor like ELISA was developed using QD-immunoprobe. • No modified primary antibody with highest activity improved biosensor performance. • QD-immunoprobe-based biosensor was highly sensitive for small molecule detection. • Reusable sensing surface was applied for multiple sensing events with low cost.

  16. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong [School of Environment and Natural Resources, Renmin University of China, Beijing (China); Shi, Hanchang [School of Environment, Tsinghua University, Beijing (China); Long, Feng, E-mail: longf04@ruc.edu.cn [School of Environment and Natural Resources, Renmin University of China, Beijing (China)

    2016-01-28

    . - Highlights: • Sandwich-like immunoassay strategy was used for rapid detection of small molecule. • Optofluidic sensing platform investigated the sandwich-like immunoassay mechanism. • A versatile optical biosensor like ELISA was developed using QD-immunoprobe. • No modified primary antibody with highest activity improved biosensor performance. • QD-immunoprobe-based biosensor was highly sensitive for small molecule detection. • Reusable sensing surface was applied for multiple sensing events with low cost.

  17. Solid phase double-antibody radioimmunoassay procedure

    International Nuclear Information System (INIS)

    Niswender, G.D.

    1977-01-01

    The present invention is concerned with the radioimmunoassay (RIA) procedure for assaying body fluid content of an antigenic substance which may either be an antigen itself or a hapten capable of being converted, such as by means of reaction with a protein, to an antigenic material. The present invention is concerned with a novel and improved modification of a double-antibody RIA technique in which there is a first antibody that is specific to the antigenic substance suspected to be present in a body fluid from which the assay is intended. The second antibody, however, is not specific to the antigenic substance or analyte, but is an antibody against the first antibody

  18. Monoclonal antibody-based ELISA to quantify the major allergen of Cynodon dactylon (Bermuda grass) pollen, Cyn d 1.

    Science.gov (United States)

    Duffort, O; Calabozo, B; González, R; Carpizo, J A; Barber, D; Polo, F

    2004-12-01

    Pollen of Bermuda grass (Cynodon dactylon) is an important cause of pollinosis in many areas of the world. Most patients show sensitivity to the major allergen Cyn d 1, a glycoprotein composed of a number of isoforms with a molecular mass of 31-32 kDa. The aim of this work was to develop a monoclonal antibody (mAb)-based ELISA to quantify Cyn d 1, and to assess the correlation of the allergen content with the biological activity of C. dactylon pollen extracts. After fusion of myeloma cells with spleen cells from a BALB/c mouse immunized with C. dactylon pollen extract, Cyn d 1-specific mAbs secreting hybridomas were selected, and the antibodies characterized. One of them (4.4.1) was used as the capture antibody in an ELISA method for Cyn d 1 quantitation. An anti-Cyn d 1 rabbit serum was used as the second antibody. Cyn d 1 was purified by immunoaffinity chromatography with mAb 4.4.1, characterized, and used as the standard in the assay. The identity, purity and isoallergen composition of affinity-purified Cyn d 1 was confirmed by N-terminal amino acid sequencing, SDS-PAGE, Western blot and 2D electrophoresis. The Cyn d 1 ELISA is highly specific and sensitive, with a detection limit of 0.24 ng/ml and a linear range of 1.1-9.2 ng/ml. An excellent correlation was found when the content of Cyn d 1, measured in 16 different extracts, was compared with the allergenic activity of the same extracts determined by RAST inhibition. The results prove the usefulness of the Cyn d 1 ELISA for the standardization of C. dactylon-allergen products on the basis of major allergen content. 2004 S. Karger AG, Basel.

  19. Comparison between an immunochromatographic test with an amplified ELISA for detecting e antigen and anti-e antigen antibodies in chronic Hepatitis B

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Aguilar Rubido; Julio C

    2009-01-01

    The disappearance of the e antigen and the appearance of anti-e antigen antibodies are two biomarkers that indicate favorable prognosis in Hepatitis B. In this study the Advanced QualityTM immunochromatographic test for detecting those biomarkers was compared to the Vidas semi-quantitative ELISA test. Our hypothesis was that it is possible to use these biomarkers measured in a rapid and simple Advanced QualityTM immunochromatographic test for evaluating the therapeutic response in clinical trials with chronic hepatitis B patients. The two methods were done following the manufacturer's instructions. The sera were taken from 69 patients with chronic hepatitis B of the clinical trial of the CIGB 440 therapeutic candidate. The immunochromatographic test and ELISA for detecting e antigen and anti-e antigen antibodies presented from substantial to almost perfect agreement in the evaluation of the sera of chronic Hepatitis B patients in a clinical trial. The immunochromatographic test for detecting e antigen had a low positive average agreement and a high negative average agreement compared to the ELISA. Nevertheless, the immunochromatographic test for detecting anti-e antigen antibodies had a high negative and positive average agreement in comparison to the ELISA. The immunochromagraphic test for the e antigen had a lower positive average agreement compared to the ELISA and some patients infected with Hepatitis B virus could not be detected by the former assay. The immunochromatographic test for anti-e antigen antibodies showed a similar performance to that of ELISA and could therefore be used in clinical trials for chronic Hepatitis B in health institutions without the need of a highly qualified lab technician. (author)

  20. Antigenisitas, Sensitivitas, dan Spesifisitas Protein Toxocara canis pada Pemeriksaan Antibodi Serum Mencit dengan Indirect-ELISA

    Directory of Open Access Journals (Sweden)

    Sri Subekti Bendryman

    2015-05-01

    Full Text Available The aim of this research were to determine antigenicity, sensitivity, and specificity of Toxocara canisprotein used as antigen in indirect-ELISA for the detection antibody against the worm in the infected hostin order to proper diagnose kit. The design used was true experimental, with Post-test Only ControlGroups Design. Mouse was immunized with various worm homogenates used to antigenicity, sensitivityand specificity tests of T. canis protein with indirect-ELISA technique. The independence variable werevarious immunogens (homogenates; the dependence variables were antigenicity, sensitivity and specificityvalues interpreted by optical density (OD value of mouse sera; and controlled variable were mouse strain,feed and retrieval time of sera. The result showed that OD values of mouse sera immunized with T. canisand T.cati homogenate were signicantly difference (p<0.01 as compared to those immunized withAncylostoma spp., Dipylidium caninum and control sera. Using the diagnosis based on the finding ofToxocara, the sensitivity of OD value by ELISA result from mouse sera immunized with Toxocara spp.homogenate were 100%. Using negative OD value by ELISA from mouse sera immunized with Ancylostomaspp. and D. caninum homogenate, the specificity of the test was 87.5%. In conclusion, protein of T.canishas the same antigenicity against anti-T. canis and anti-T. cati sera, but they had the lower antigenicityagainst anti-Ancylostoma spp. and anti-D.caninum sera. As the sensitivity value of 100% and specificityvalue of 87.5%, in detecting antibody against toxocariasis, the possibility of obtaining false positive was12.5%.

  1. Development of Monoclonal Antibodies Recognizing Linear Epitope: Illustration by Three Bacillus thuringiensis Crystal Proteins of Genetically Modified Cotton, Maize, and Tobacco.

    Science.gov (United States)

    Cao, Zhen; Zhang, Wei; Ning, Xiangxue; Wang, Baomin; Liu, Yunjun; Li, Qing X

    2017-11-22

    Bacillus thuringiensis Cry1Ac, Cry1Ia1, and Cry1Ie are δ-endotoxin insecticidal proteins widely implemented in genetically modified organisms (GMO), such as cotton, maize, and potato. Western blot assay integrates electrophoresis separation power and antibody high specificity for monitoring specific exogenous proteins expressed in GMO. Procedures for evoking monoclonal antibody (mAb) for Western blot were poorly documented. In the present study, Cry1Ac partially denatured at 100 °C for 5 min was used as an immunogen to develop mAbs selectively recognizing a linear epitope of Cry1Ac for Western blot. mAb 5E9C6 and 3E6E2 selected with sandwich ELISA strongly recognized the heat semidenatured Cry1Ac. Particularly, 3E6E2 recognized both E. coli and cotton seed expressed Cry1Ac in Western blot. Such strategy of using partially denatured proteins as immunogens and using sandwich ELISA for mAb screening was also successfully demonstrated with production of mAbs against Cry1Ie for Western blot assay in maize.

  2. Immunodiagnosis of Human Fascioliasis by an Enzyme-Linked Immunosorbent Assay (ELISA) and a Micro-ELISA

    OpenAIRE

    Carnevale, Silvana; Rodríguez, Mónica I.; Santillán, Graciela; Labbé, Jorge H.; Cabrera, Marta G.; Bellegarde, Enrique J.; Velásquez, Jorge N.; Trgovcic, Jorge E.; Guarnera, Eduardo A.

    2001-01-01

    Enzyme-linked immunosorbent assay (ELISA) and micro-ELISA were evaluated for their ability to detect anti-Fasciola hepatica antibodies in humans by using excretory-secretory antigen. The sensitivity of each method was 100%, but the specificity was 100% for ELISA and 97% for micro-ELISA. The micro-ELISA could be used as a screening assay and ELISA could be used as a confirmatory method for the serodiagnosis of human fascioliasis.

  3. Application of commercial enzyme linked immunosorbent assays (ELISA for the detection of antibodies for foot-and-mouth disease virus in wild boar and red deer

    Directory of Open Access Journals (Sweden)

    Terzić Svjetlana

    2012-01-01

    Full Text Available For detecting antibodies towards foot and mouth (FMD virus in sera collected from red deer hinds (Cervus elaphus and wild boars (Sus scrofa, three commercially available enzyme-linked immunosorbent assays (ELISA were used. Two ELISA kits (PrioCHECK FMDV NS and CHEKIT FMD-3ABC were used for the detection of antibodies towards non-structural proteins of FMD virus and one assay was based on the detection of antibodies for serotype O (PrioCHECK FMDV type O. All of the sera tested in our study were negative for antibodies against FMD virus. The aim of this study was to investigate the usefulness of commercially available ELISA kits given for marketing authorization in Croatia in testing the prevalence of FMD antibodies in wild boar and red deer populations. Since the producers of ELISA kits used in our study did not declare wild animals as a target species, we hypothesised that the same kits could be used for serological diagnosis of FMD in red deer and wild boars. Our study confirmed that the kits used are acceptable for detecting antibodies in both species tested, however, the investigation highlighted the problem of validating the kits due to the absence of available positive sera originating from red deer, as well as other susceptible species, especially artiodactyls.

  4. Generation of monoclonal antibodies against peptidylarginine deiminase 2 (PAD2) and development of a PAD2-specific enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Damgaard, Dres; Palarasah, Yaseelan; Skjødt, Karsten

    2014-01-01

    The enzyme peptidylarginine deiminase 2 (PAD2) has been associated with inflammatory diseases, such as rheumatoid arthritis and neurodegenerative diseases including multiple sclerosis. To investigate the association of various diseases with extracellular PAD2, we raised monoclonal antibodies (m......Abs) against rabbit PAD2 and evaluated their cross-reactivity with human PAD2 by indirect enzyme-linked immunosorbent assay (ELISA), western blotting and immunohistological staining of inflamed synovial tissue. Moreover, we established a sandwich ELISA detecting human PAD2, based on two different monoclonal...... diseases....

  5. Seroprevalence of Mycoplasma gallisepticum antibody by ELISA and serum plate agglutination test of laying chicken

    Directory of Open Access Journals (Sweden)

    Md. Zulfekar Ali

    2015-01-01

    Full Text Available Aim: Mycoplasma gallisepticum (MG is important avian pathogen responsible for chronic respiratory disease of chicken and turkeys, which result in large economic loss for the poultry industry. The objectives of this study were determination of seroprevalence of MG antibody of commercial layer chicken at laying period in selected areas of Bangladesh. Materials and Methods: A total of 563 blood samples were collected randomly from selected commercial layer chickens at laying period during the period from July to December, 2013. Indirect enzyme linked immunosorbent assay (iELISA and serum plate agglutination (SPA test were performed to detect the presence of antibodies against MG. Results: Of 563 samples, 64.47% and 56.13% showed an overall prevalence of MG antibodies in iELISA and SPA test respectively. Prevalence of MG was recorded the highest (69.63% at 50-55 weeks of age compared with lowest (53.26% at 56-61 weeks of age (p<0.05. Significant (p<0.05 effect of breed were observed in the seroprevalence of MG infection in layer birds in the present study. The overall, 68.77%, 63.74% and 59.37% prevalence were found respectively in sonali, ISA Brown and White leg horn. The prevalence of MG antibodies was the highest (70.13% in December followed by November (68%, October (65.67%, August (63.46%, September (58.54% and July (51.78% month. The seroprevalence of MG antibodies was higher (69.63% in most of the large flocks and lower (56.82% in small flocks. Conclusion: Therefore, might be suggested that the commercial layer farms should be routinely checked to monitor MG infection and the reactor birds should be culled since MG organism has the potential to transmit vertically. The correlation between MG antibody in month and flock size was not significant (p=0.359 and p=0.868, respectively.

  6. Screening for single-chain variable fragment antibodies against multiple Cry1 toxins from an immunized mouse phage display antibody library.

    Science.gov (United States)

    Dong, Sa; Bo, Zongyi; Zhang, Cunzheng; Feng, Jianguo; Liu, Xianjin

    2018-04-01

    Single-chain variable fragment (scFv) is a kind of antibody that possess only one chain of the complete antibody while maintaining the antigen-specific binding abilities and can be expressed in prokaryotic system. In this study, scFvs against Cry1 toxins were screened out from an immunized mouse phage displayed antibody library, which was successfully constructed with capacity of 6.25 × 10 7  CFU/mL. Using the mixed and alternative antigen coating strategy and after four rounds of affinity screening, seven positive phage-scFvs against Cry1 toxins were selected and characterized. Among them, clone scFv-3H9 (MG214869) showing relative stable and high binding abilities to six Cry1 toxins was selected for expression and purification. SDS-PAGE indicated that the scFv-3H9 fragments approximately 27 kDa were successfully expressed in Escherichia coli HB2151 strain. The purified scFv-3H9 was used to establish the double antibody sandwich enzyme-linked immunosorbent assay method (DAS-ELISA) for detecting six Cry1 toxins, of which the lowest detectable limits (LOD) and the lowest quantitative limits (LOQ) were 3.14-11.07 and 8.22-39.44 ng mL -1 , respectively, with the correlation coefficient higher than 0.997. The average recoveries of Cry1 toxins from spiked rice leaf samples were ranged from 84 to 95%, with coefficient of variation (CV) less than 8.2%, showing good accuracy for the multi-residue determination of six Cry1 toxins in agricultural samples. This research suggested that the constructed phage display antibody library based on the animal which was immunized with the mixture of several antigens under the same category can be used for the quick and effective screening of generic antibodies.

  7. The evaluation of a nucleoprotein ELISA for the detection of equine influenza antibodies and the differentiation of infected from vaccinated horses (DIVA).

    Science.gov (United States)

    Galvin, Pamela; Gildea, Sarah; Arkins, Sean; Walsh, Cathal; Cullinane, Ann

    2013-12-01

    Antibodies against equine influenza virus (EIV) are traditionally quantified by haemagglutination inhibition (HI) or single radial haemolysis (SRH). To evaluate an ELISA for the detection of antibodies against influenza nucleoprotein in the diagnosis and surveillance of equine influenza (EI). The ELISA was compared with the SRH and HI tests. Serial serum samples from 203 naturally and 14 experimentally infected horses, from 60 weanlings following primary vaccination with five different vaccines (two whole inactivated vaccines, two ISCOM-based subunit vaccines and a recombinant canarypox virus vaccine) and from 44 adult horses following annual booster vaccination with six different vaccines were analysed. Fewer seroconversions were detected in clinical samples by ELISA than by SRH or HI but ELISA was more sensitive than SRH in naïve foals post-experimental infection. The ELISA did not detect the antibody response to vaccination with the recombinant canarypox virus vaccine confirming the usefulness of the combination of this kit and vaccine to differentiate between naturally infected and vaccinated horses, that is, DIVA. No DIVA capacity was evident with the other vaccines. The results suggest that this ELISA is a useful supplementary test for the diagnosis of EI although less sensitive than HI or SRH. It is an appropriate test for EI surveillance in a naïve population and may be combined with the recombinant canarypox virus vaccine but not with other commercially available subunit vaccines, in a DIVA strategy. © 2013 Blackwell Publishing Ltd.

  8. Comparison of printed glycan array, suspension array and ELISA in the detection of human anti-glycan antibodies.

    Science.gov (United States)

    Pochechueva, Tatiana; Jacob, Francis; Goldstein, Darlene R; Huflejt, Margaret E; Chinarev, Alexander; Caduff, Rosemarie; Fink, Daniel; Hacker, Neville; Bovin, Nicolai V; Heinzelmann-Schwarz, Viola

    2011-12-01

    Anti-glycan antibodies represent a vast and yet insufficiently investigated subpopulation of naturally occurring and adaptive antibodies in humans. Recently, a variety of glycan-based microarrays emerged, allowing high-throughput profiling of a large repertoire of antibodies. As there are no direct approaches for comparison and evaluation of multi-glycan assays we compared three glycan-based immunoassays, namely printed glycan array (PGA), fluorescent microsphere-based suspension array (SA) and ELISA for their efficacy and selectivity in profiling anti-glycan antibodies in a cohort of 48 patients with and without ovarian cancer. The ABO blood group glycan antigens were selected as well recognized ligands for sensitivity and specificity assessments. As another ligand we selected P(1), a member of the P blood group system recently identified by PGA as a potential ovarian cancer biomarker. All three glyco-immunoassays reflected the known ABO blood groups with high performance. In contrast, anti-P(1) antibody binding profiles displayed much lower concordance. Whilst anti-P(1) antibody levels between benign controls and ovarian cancer patients were significantly discriminated using PGA (p=0.004), we got only similar results using SA (p=0.03) but not for ELISA. Our findings demonstrate that whilst assays were largely positively correlated, each presents unique characteristic features and should be validated by an independent patient cohort rather than another array technique. The variety between methods presumably reflects the differences in glycan presentation and the antigen/antibody ratio, assay conditions and detection technique. This indicates that the glycan-antibody interaction of interest has to guide the assay selection. © The Author(s) 2011. This article is published with open access at Springerlink.com

  9. Development of monoclonal antibodies bearing the internal image of the gizzerosine epitope and application in a competitive ELISA for fish meal.

    Science.gov (United States)

    Manosalva, Headdy; De Ioannes, Alfredo E; Becker, María Inés

    2004-02-01

    Gizzerosine (GZ), a derivative of histamine, is a biogenic amine found in fish meal, and one of the causative agents of black vomit, a poultry disease. We describe here the preparation of anti-idiotype antibodies to the anti-GZ monoclonal antibody (anti-GZ 3H4) and their possible application to an immunoassay. BALB-c mice were immunized with anti-GZ 3H4 antibody coupled to hemocyanin from Concholepas concholepas. Using somatic cell fusion between NSO/2 cells and splenic lymphocytes from the immunized mice, we obtained 34 potential anti-idiotype antibodies. They were characterized by passive agglutination with supernatants from hybridoma cultures and latex particles conjugated to the idiotype. Anti-idiotype antibodies were analyzed by a competitive RIA, to determine their ability to dissociate the interaction between (125)I-GZ and the anti-GZ 3H4-idiotype antibody. They were also characterized by GZ inhibition of latex passive agglutination assay. Three anti-idiotypes named 2D11, 2H6, and 3A12, all of the IgG isotype, were obtained. They were evaluated by a competitive ELISA, in which GZ competes with the tracer (HRP-idiotype). All presented sensitivity in the range of 0.1-10 microg/mL of GZ; and the 3A12 anti-idiotype antibody showed the best performance. An ELISA was developed using the idiotype bound to the solid phase and the anti-idiotype 3A12-HRP as the tracer. The assay showed a similar sensitivity and cross-reactivity with histamine was only observed at concentrations over 10 microg/mL. Lysine and histidine did not interfere with the assay up to 500 microg/mL. An experiment was conducted with fish meal contaminated with synthetic GZ. The results are promising, and showed that no other compounds of the fish meal interfere with the ELISA system; however the extraction procedure of the sample needs to be improved. From the results presented here, we conclude that the idiotype anti-idiotype ELISA would be an appropriate method to determine GZ in fish meal.

  10. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    OpenAIRE

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-St...

  11. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    OpenAIRE

    Yanil R Parma; Pablo A Chacana; Paula María Alejandra Lucchesi; Ariel eRoge; Claudia V Granobles Velandia; Alejandra eKrüger; Alejandra eKrüger; Alberto E. Parma; Mariano Enrique Fernandez Miyakawa

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-St...

  12. Development and application of radioimmunoassays and enzyme immunoassays in microbiological and immunological diagnosis. 2. Comparative studies for the detection of toxoplasma antibodies with ELISA, RIA and other serological methods

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, W A; Struy, H; Holzwarth, F [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Comparative studies of indirect immunofluorescence test (IT), complement binding reaction (CBR), enzyme- and radioimmunoassay (ELISA, RIA) for the detection of toxoplasma antibodies in sera of 513 patients are reported. The precision dependent on time, showed coefficients of variation from 3% to 12% (IFT 3%, CBR 10%, ELISA 12%, RIA 7%). The correlation of IFT and ELISA as well as RIA was relatively unfavourable (coefficient of correlation IFT/ELISA r = 0.52, IFT/RIA r = 0.54, RIA/ELISA r = 0.60). The ELISA is the most sensitive method for the detection of antibodies. The specificity of the Toxo-ELISA has to be improved by application of suitable fractions of antigens.

  13. Effects of external and gap mean flows on sound transmission through a double-wall sandwich panel

    Science.gov (United States)

    Liu, Yu; Sebastian, Alexis

    2015-05-01

    This paper studies analytically the effects of an external mean flow and an internal gap mean flow on sound transmission through a double-wall sandwich panel lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials, and the transfer matrix method with three types of boundary conditions is applied to solve the system simultaneously. The random incidence transmission loss in a diffuse field is calculated numerically, and the limiting angle of incidence due to total internal reflection is discussed in detail. The numerical predictions suggest that the sound insulation performance of such a double-wall panel is enhanced considerably by both external and gap mean flows particularly in the high-frequency range. Similar effects on transmission loss are observed for the two mean flows. It is shown that the effect of the gap mean flow depends on flow velocity, flow direction, gap depth and fluid properties and also that the fluid properties within the gap appear to influence the transmission loss more effectively than the gap flow. Despite the implementation difficulty in practice, an internal gap flow provides more design space for tuning the sound insulation performance of a double-wall sandwich panel and has great potential for active/passive noise control.

  14. Radioimmunological proof of thyroglobulin antibodies in humans by the use of a double antibody method

    International Nuclear Information System (INIS)

    Waller, V.

    1982-01-01

    Thyroid antibodies, especially thyroglobulin antibodies, allow themselves to be proven with the double antibody method, in competitive radio binding assays and with the solid phase technique. These methods offer advantages relative to sensitivity and quantifiability. In this work a sensitive radioimmunoassay as a double antibody method was worked out whereby a 125 I-thyroglobulin/thyroglobulin antibody immune complex was precipitated out using anti-human immunoglobulin. The measured results from the radioimmunoassay show a good correlation with the results of the immune histological findings. A high to very high Tg antibody level occurs with autoimmune thyroiditis (80%), primary hypothyroidism (74%) and hyperthyroidism (70%). The control values with healthy people came to less than 5% specific binding. In correlation with the results of other authors this method is advantageous relative to test start and evaluation procedures. (orig.) [de

  15. Validation of a commercially available indirect ELISA using a nucleocapside recombinant protein for detection of Schmallenberg virus antibodies.

    Directory of Open Access Journals (Sweden)

    Emmanuel Bréard

    Full Text Available A newly developed Enzym Like Immuno Sorbant Assay (ELISA based on the recombinant nucleocapsid protein (N of Schmallenberg virus (SBV was evaluated and validated for the detection of SBV-specific IgG antibodies in ruminant sera by three European Reference Laboratories. Validation data sets derived from sheep, goat and bovine sera collected in France and Germany (n = 1515 in 2011 and 2012 were categorized according to the results of a virus neutralization test (VNT or an indirect immuno-fluorescence assay (IFA. The specificity was evaluated with 1364 sera from sheep, goat and bovine collected in France and Belgium before 2009. Overall agreement between VNT and ELISA was 98.9% and 98.3% between VNT and IFA, indicating a very good concordance between the different techniques. Although cross-reactions with other Orthobunyavirus from the Simbu serogroup viruses might occur, it is a highly sensitive, specific and robust ELISA-test validated to detect anti-SBV antibodies. This test can be applied for SBV sero-diagnostics and disease-surveillance studies in ruminant species in Europe.

  16. Development of an Indirect ELISA Based on a Recombinant Chimeric Protein for the Detection of Antibodies against Bovine Babesiosis.

    Science.gov (United States)

    Jaramillo Ortiz, José Manuel; Montenegro, Valeria Noely; de la Fournière, Sofía Ana María; Sarmiento, Néstor Fabián; Farber, Marisa Diana; Wilkowsky, Silvina Elizabeth

    2018-01-23

    The current method for Babesia spp. serodiagnosis based on a crude merozoite antigen is a complex and time-consuming procedure. An indirect enzyme-linked immunosorbent assay (iELISA) based on a recombinant multi-antigen of Babesia bovis (rMABbO) was developed for detection of antibodies in bovines suspected of infection with this parasite. The multi-antigen comprises gene fragments of three previously characterized B. bovis antigens: MSA-2c, RAP-1 and the Heat Shock protein 20 that are well-conserved among geographically distant strains. The cutoff value for the new rMABbo-iELISA was determined using 75 known-positive and 300 known-negative bovine sera previously tested for antibodies to B. bovis by the gold-standard ELISA which uses a merozoite lysate. A cutoff value of ≥35% was determined in these samples by receiver operator characteristic (ROC) curve analysis, showing a sensitivity of 95.9% and a specificity of 94.3%. The rMABbo-iELISA was further tested in a blind trial using an additional set of 263 field bovine sera from enzootic and tick-free regions of Argentina. Results showed a good agreement with the gold standard test with a Cohen's kappa value of 0.76. Finally, the prevalence of bovine babesiosis in different tick enzootic regions of Argentina was analyzed where seropositivity values among 68-80% were obtained. A certain level of cross reaction was observed when samples from B. bigemina infected cattle were analyzed with the new test, which can be attributed to shared epitopes between 2 of the 3 antigens. This new rMABbo-iELISA could be considered a simpler alternative to detect anti Babesia spp. antibodies and appears to be well suited to perform epidemiological surveys at the herd level in regions where ticks are present.

  17. Development and validation of an epitope-blocking ELISA using an anti-haemagglutinin monoclonal antibody for specific detection of antibodies in sheep and goat sera directed against peste des petits ruminants virus.

    Science.gov (United States)

    Bodjo, Sanne Charles; Baziki, Jean-de-Dieu; Nwankpa, Nick; Chitsungo, Ethel; Koffi, Yao Mathurin; Couacy-Hymann, Emmanuel; Diop, Mariame; Gizaw, Daniel; Tajelser, Idris Badri Adam; Lelenta, Mamadou; Diallo, Adama; Tounkara, Karim

    2018-07-01

    Peste des petits ruminants (PPR) is a contagious and economically important disease affecting production of small ruminants (i.e., sheep and goats). Taking into consideration the lessons learnt from the Global Rinderpest Eradication Programme (GREP), PPR is now targeted by the international veterinary community as the next animal disease to be eradicated. To support the African continental programme for the control of PPR, the Pan African Veterinary Vaccine Centre of the African Union (AU-PANVAC) is developing diagnostics tools. Here, we describe the development of a blocking enzyme-linked immunosorbent assay (bELISA) that allows testing of a large number of samples for specific detection of antibodies directed against PPR virus in sheep and goat sera. The PPR bELISA uses an anti-haemagglutinin (H) monoclonal antibody (MAb) as a competitor antibody, and tests results are interpreted using the percentage of inhibition (PI) of MAb binding generated by the serum sample. PI values below or equal to 18% (PI ≤ 18%) are negative, PI values greater than or equal to 25% (PI ≥ 25%) are positive, and PI values greater than 18% and below 25% are doubtful. The diagnostic specificity (DSp) and diagnostic sensitivity (DSe) were found to be 100% and 93.74%, respectively. The H-based PPR-bELISA showed good correlation with the virus neutralization test (VNT), the gold standard test, with a kappa value of 0.947. The H-based PPR-bELISA is more specific than the commercial kit ID Screen® PPR Competition (N-based PPR-cELISA) from IDvet (France), but the commercial kit is slightly more sensitive than the H-based PPR-bELISA. The validation process also indicated good repeatability and reproducibility of the H-based PPR-bELISA, making this new test a suitable tool for the surveillance and sero-monitoring of the vaccination campaign.

  18. Detection of thyroid stimulating hormone receptor antibodies (TRAb) by radioreceptor assay (RRA) and enzyme-linked immunosorbent assay (ELISA)

    International Nuclear Information System (INIS)

    Dumrongpisutikul, S.; Tuchinda, S.

    1990-01-01

    Thyroid stimulating hormone receptor antibodies (TRAb) were determined in 100 patients using radioreceptor assay (RRA) and enzyme-linked immunosorbent assay (ELISA). The sensitivity of RRA and ELISA were found to be 70.6% and 88.2% respectively (n=51). The specificity of both assays were 100% (n=16). With RRA as the standard test the sensitivity and specificity of ELISA were 75.8% and 86.8%. In the untreated hyperthyroid the RRA result which expressed as % specific 125 I-TSH inhibition was 33.6% (n=51), decline to 26.9% in the treated hyperthyroid (n=33) and 14.1% in the euthyroid (n=16). The mean 0.D 492nm of TRAb-ELISA were 0.861 in untreated hyperthyroid, 0.437 in treated hyperthyroid and 0.135 in euthyroid Phi coefficient analysis show that the RRA was 60.4% correlated to hyperthyroidism where as TRAb-ELISA was 80.1%

  19. Development of a blocking ELISA for detection of serum neutralizing antibodies against newly emerged duck Tembusu virus.

    Directory of Open Access Journals (Sweden)

    Xuesong Li

    Full Text Available BACKGROUND: Since April 2010, domesticated ducks in China have been suffering from an emerging infectious disease characterized by retarded growth, high fever, loss of appetite, decline in egg production, and death. The causative agent was identified as a duck Tembusu virus (DTMUV, a member of the Ntaya virus (NTAV group within the genus Flavivirus, family Flaviviridae. DTMUV is highly contagious and spreads rapidly in many species of ducks. More than 10 million shelducks have been infected and approximately 1 million died in 2010. The disease remains a constant threat to the duck industry; however, it is not known whether DTMUV can infect humans or other mammalians, despite the fact that the virus has spread widely in southeast China, one of the most densely populated areas in the world. The lack of reliable methods to detect the serum antibodies against DTMUV has limited our ability to conduct epidemiological investigations in various natural hosts and to evaluate the efficiency of vaccines to DTMUV. METHODOLOGY/PRINCIPAL FINDINGS: A neutralizing monoclonal antibody (mAb 1F5 binding specifically to the E protein was developed. Based on the mAb, a blocking enzyme-linked immunosorbent assay (ELISA was developed for the detection of neutralizing antibodies against DTMUV. The average value of percent inhibition (PI of 350 duck serum samples obtained from DTMUV-free farms was 1.0% ± 5.8% (mean ± SD. The selected cut-off PI values for negative and positive sera were 12.6% (mean +2SD and 18.4% (mean +3SD, respectively. When compared with a serum neutralizing antibody test (SNT using chicken embryonated eggs, the rate of coincidence was 70.6% between the blocking ELISA and SNT, based on the titration of 20 duck DTMUV-positive serum samples. CONCLUSIONS/SIGNIFICANCE: The blocking ELISA based on a neutralizing mAb allowed rapid, sensitive, and specific detection of neutralization-related antibodies against DTMUV.

  20. A new ELISA for the quantification of equine procalcitonin in plasma as potential inflammation biomarker in horses.

    Science.gov (United States)

    Rieger, Martin; Kochleus, Christian; Teschner, Dana; Rascher, Daniela; Barton, Ann Kristin; Geerlof, Arie; Kremmer, Elisabeth; Schmid, Michael; Hartmann, Anton; Gehlen, Heidrun

    2014-09-01

    In human medicine, procalcitonin (PCT) is a very common and well-established biomarker for sepsis. Even though sepsis is also a leading cause of death in foals and adult horses, up to now, no data about the role of equine PCT in septic horses has been available. Based on monoclonal antibodies targeted against human PCT, we report here the development of a sandwich ELISA for the quantification of equine PCT in equine plasma samples. The ELISA was characterized for intra- and interassay variance and a working range from 25 to 1,000 ng mL(-1) was defined as within this range; both intra- and interassay variances were below 15 %. The target recovery ranged between 73 and 106 %. The ELISA was used to determine the equine PCT concentration in 24 healthy and 5 septic horses to show the potential for clinical evaluation of equine PCT. Significantly different (P = 0.0006) mean equine PCT concentrations were found for the healthy control group and the sepsis group (47 and 8,450 ng mL(-1)).

  1. Generation of polyclonal antibody with high avidity to rosuvastatin and its use in development of highly sensitive ELISA for determination of rosuvastatin in plasma

    Directory of Open Access Journals (Sweden)

    Al-Malaq Hamoud A

    2011-07-01

    Full Text Available Abstract In this study, a polyclonal antibody with high avidity and specificity to the potent hypocholesterolaemic agent rosuvastatin (ROS has been prepared and used in the development of highly sensitive enzyme-linked immunosorbent assay (ELISA for determination of ROS in plasma. ROS was coupled to keyhole limpt hemocyanin (KLH and bovine serum albumin (BSA using carbodiimide reagent. ROS-KLH conjugate was used for immunization of female 8-weeks old New Zealand white rabbits. The immune response of the rabbits was monitored by direct ELISA using ROS-BSA immobilized onto microwell plates as a solid phase. The rabbit that showed the highest antibody titer and avidity to ROS was scarified and its sera were collected. The IgG fraction was isolated and purified by avidity chromatography on protein A column. The purified antibody showed high avidity to ROS; IC50 = 0.4 ng/ml. The specificity of the antibody for ROS was evaluated by indirect ELISA using various competitors from the ROS-structural analogues and the therapeutic agents used with ROS in a combination therapy. The proposed ELISA involved a competitive binding reaction between ROS, in plasma sample, and the immobilized ROS-BSA for the binding sites on a limited amount of the anti-ROS antibody. The bound anti-ROS antibody was quantified with horseradish peroxidase-labeled second anti-rabbit IgG antibody (HRP-IgG and 3,3',5,5'-tetramethylbenzidine (TMB as a substrate for the peroxidase enzyme. The concentration of ROS in the sample was quantified by its ability to inhibit the binding of the anti-ROS antibody to the immobilized ROS-BSA and subsequently the color intensity in the assay wells. The assay enabled the determination of ROS in plasma at concentrations as low as 40 pg/ml.

  2. Indirect Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The indirect competitive ELISA (indirect cELISA) pits plate-immobilized antigen against antigens in solution for binding to antigen-specific antibody. The antigens in solution are in the test sample and are first incubated with antigen-specific antibody. These antibody-antigen complexes are then added to microtiter plates whose wells have been coated with purified antigen. The wells are washed to remove unbound antigen-antibody complexes and free antigen. A reporter-labeled secondary antibody is then added followed by the addition of substrate. Substrate hydrolysis yields a signal that is inversely proportional to antigen concentration within the sample. This is because when antigen concentration is high in the test sample, most of the antibody is bound before adding the solution to the plate. Most of the antibody remains in solution (as complexes) and is thus washed away before the addition of the reporter-labeled secondary antibody and substrate. Thus, the higher the antigen concentration in the test sample, the weaker the resultant signal in the detection step. The indirect cELISA is often used for competitive detection and quantification of antibodies against viral diseases in biological samples. © 2017 Cold Spring Harbor Laboratory Press.

  3. Validation of a commercial ELISA for the detection of bluetongue virus (BTV) specific antibodies in individual milk samples of Dutch dairy cows

    NARCIS (Netherlands)

    Kramps, J.A.; Maanen, van K.; Mars, M.H.; Popma, J.K.; Rijn, van P.A.

    2008-01-01

    recently developed indirect ELISA for the detection of bluetongue virus (BTV)-specific antibodies in bovine milk samples was compared to that of the routinely used competitive ELISA on serum samples. During the bluetongue outbreak in the Netherlands in 2006, caused by BTV serotype 8, coupled serum

  4. Comparison of a direct and indirect ELISA for quantitating antisperm antibody in semen.

    Science.gov (United States)

    Lynch, D M; Howe, S E

    1987-01-01

    A direct and an indirect quantitative ELISA for antisperm antibody were compared using the spermatozoa and cell-free seminal fluid of 66 infertile males. The normal concentration of sperm binding immunoglobulin was less than or equal to 1.5 fg Ig per spermatozoon for the indirect seminal plasma assay and less than or equal to 1.5 fg Ig per spermatozoon by the direct assay. Of the 66 infertile males, 21% (14/66) had elevated levels of antisperm antibody in their seminal plasma and 26% (17/66) had elevated levels bound directly to their spermatozoa. The direct correlation between the results of these assays was 94%. A simple linear regression analysis between the indirect and direct measurements of antisperm antibody resulted in a correlation coefficient of r = 0.907. There was no statistically significant difference between results from the direct and indirect methods of the patients as a group. However, there was evidence of autospecificity in a small percentage of males who had elevated levels of antisperm antibody by the direct assay that was not detected by the indirect assay using pooled donor spermatozoa.

  5. Monoclonal antibody-based serological methods for detection of Cucumber green mottle mosaic virus

    Directory of Open Access Journals (Sweden)

    Qian Yajuan

    2011-05-01

    Full Text Available Abstract Background Cucumber green mottle mosaic virus (CGMMV, a member of the genus Tobamovirus, can be transmitted by seeds and infects many cucurbit species, causing serious yield losses in cucumber and watermelon plants. In this paper, five serological methods including antigen-coated plate enzyme-linked immunosorbent assay (ACP-ELISA, triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA, Dot-immunobinding assay (DBIA, direct tissue blot immunoassay (DTBIA and immunocapture reverse transcriptase polymerase chain reaction (IC-RT-PCR were described for detection and diagnosis of CGMMV. Results Using the purified CGMMV particles as immunogens, six murine monoclonal antibodies (MAbs were produced. Five serological methods were established using the MAb 4H1 and detection sensitivity was compared using purified preparations and infected-plant tissue extracts. The detection sensitivity of ACP-ELISA was 0.16 ng of purified CGMMV, whereas TAS-ELISA was more sensitive than ACP-ELISA with a minimum detection of 0.04 ng of purified CGMMV. The sensitivities of TAS-ELISA and DBIA were similar for detecting CGMMV in infected-plant tissue extracts, and were four times higher than ACP-ELISA. The IC-RT-PCR was the most sensitive method, which could detect as little as 0.1 pg of purified virus. The detection sensitivity of IC-RT-PCR for CGMMV-infected plant tissues was about 400 times higher than that of TAS-ELISA and DBIA. Conclusions The established ACP-ELISA, TAS-ELISA, DBIA and DTBIA are suitable for routine CGMMV detection of large-scale samples in the field survey, while IC-RT-PCR is more sensitive and suitable for acquiring information about the viral genome.

  6. The impact of milk handling procedures on Ostertagia ostertagi antibody ELISA test results.

    Science.gov (United States)

    Vanderstichel, Raphaël; Dohoo, Ian; Stryhn, Henrik

    2010-04-19

    The impact of various milk handling stressors were analyzed using a commercially available enzyme-linked immunosorbent assay (ELISA) test measuring Ostertagia ostertagi antibodies in milk from dairy cattle (Svanovir). An indirect ELISA has the ability to determine the amount of milk production losses related to intestinal parasitism. The ELISA test recommends fresh defatted milk, however, milk collected from Dairy Herd Improvement (DHI) programs in North America undergo many stressors, including, heating, freezing and are not defatted. Normalized optical density ratios (ODRs) were compared between fresh defatted milk and milk subjected to one or more stressors with a linear mixed model accounting for differences in variation between the fresh and the frozen samples. Concordance correlation coefficients were also analyzed for comparisons to other similar studies. After accounting for random cow and container effects, the treatment factors interacted with each other (p<0.001). Biologically interesting contrasts were created to explain the interaction. The estimated difference in ODR between the milk samples handled according to recommendations of the manufacturers of Svanovir and the whole milk samples that were subjected to the most extreme treatment (heated, frozen, thawed, and re-frozen for 4 weeks) was 0.062 (p<0.001). This difference represented less than 5% of the range, and was thus considered biologically negligible. Frozen whole milk processed by DHI programs, the most likely method of collecting on-farm samples in North America, will likely yield reliable results for the indirect ELISA tests, particularly, Svanovir.

  7. Electronic Cortisol Detection Using an Antibody-Embedded Polymer Coupled to a Field-Effect Transistor.

    Science.gov (United States)

    Jang, Hyun-June; Lee, Taein; Song, Jian; Russell, Luisa; Li, Hui; Dailey, Jennifer; Searson, Peter C; Katz, Howard E

    2018-05-16

    A field-effect transistor-based cortisol sensor was demonstrated in physiological conditions. An antibody-embedded polymer on the remote gate was proposed to overcome the Debye length issue (λ D ). The sensing membrane was made by linking poly(styrene- co-methacrylic acid) (PSMA) with anticortisol before coating the modified polymer on the remote gate. The embedded receptor in the polymer showed sensitivity from 10 fg/mL to 10 ng/mL for cortisol and a limit of detection (LOD) of 1 pg/mL in 1× PBS where λ D is 0.2 nm. A LOD of 1 ng/mL was shown in lightly buffered artificial sweat. Finally, a sandwich ELISA confirmed the antibody binding activity of antibody-embedded PSMA.

  8. Dot-ELISA affinity test: an easy, low-cost method to estimate binding activity of monoclonal antibodies

    Czech Academy of Sciences Publication Activity Database

    Svobodová, Z.; Jankovičová, B.; Horák, Daniel; Bílková, Z.

    2013-01-01

    Roč. 4, č. 3 (2013), 1000168_1-1000168_5 ISSN 2155-9872 R&D Projects: GA MŠk 7E12053; GA MŠk 7E09109 EU Projects: European Commission(XE) 246513 - NADINE; European Commission(XE) 228980 - CAMINEMS Institutional support: RVO:61389013 Keywords : dot-ELISA * affinity * monoclonal antibody Subject RIV: CD - Macromolecular Chemistry

  9. Synthesis-based approach toward direct sandwich immunoassay for ciguatoxin CTX3C.

    Science.gov (United States)

    Oguri, Hiroki; Hirama, Masahiro; Tsumuraya, Takeshi; Fujii, Ikuo; Maruyama, Megumi; Uehara, Hisatoshi; Nagumo, Yoko

    2003-06-25

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of ciguatoxin CTX3C were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens, 3 and 4, in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C itself. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C at the ppb level with no cross-reactivity against other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin.

  10. Differentiation of infection from vaccination in foot-and-mouth disease by the detection of antibodies to the non-structural proteins 3D, 3AB and 3ABC in ELISA using antigens expressed in baculovirus

    DEFF Research Database (Denmark)

    Sørensen, K.J.; Madsen, K.G.; Madsen, E.S.

    1998-01-01

    The baculovirus expression system was found to be efficient at expressing the 3D, the 3AB and the 3ABC non-structural proteins (NSP) of foot-and-mouth disease virus (FMDV) as antigens recognised by immune sera in ELISA. ELISA's using 3D, 3AB and 3ABC detected antibodies from day 8 and 10 after...... experimental infection of susceptible cattle and sheep and cattle remained seropositive for more than 395 days. The ELISA's detected antibodies against any of the seven serotypes of FMDV. The 3D ELISA was specific and precise and as sensitive as established ELISA's which measure antibody to structural proteins....... The assay may be used as a resource saving alternative to established ELISA's for the detection of antibodies against any of the seven serotypes. The 3AB and the 3ABC ELISA were also specific and precise. FMDV infected cattle could be differentiated from those that had been merely vaccinated as they gave...

  11. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    Science.gov (United States)

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  12. Immunodiagnosis of fascioliasis using sandwich enzyme-linked immunosorbent assay for detection of Fasciola gigantica paramyosin antigen

    Science.gov (United States)

    Abou-Elhakam, Hany Mohamed Adel; Bauomy, Ibraheem Rabia; El Deeb, Somaya Osman; El Amir, Azza Mohamed

    2013-01-01

    Background: Many immunological techniques have been developed over years using the different Fasciola antigens for diagnosis of parasitic infection and to replace the parasitological techniques, which are time consuming and usually lack sensitivity and reproducibility. Materials and Methods: In this study, Fasciola gigantica paramyosin (Pmy) antigen was early detected in cattle sera using sandwich enzyme-linked immunosorbent assay (ELISA), to evaluate the Pmy antigen performance in diagnosis. This work was conducted on 135 cattle blood samples, which were classified according to parasitological investigation into, healthy control (30), fascioliasis (75), and other parasites (30) groups. Results: The sensitivity of Sandwich ELISA was 97.33%, and the specificity was 95%, in comparison with parasitological examination, which recorded 66.66% sensitivity and 100% specificity, respectively. Conclusions: It was clear that the native F. gigantica Pmy is considered as a powerful antigen in early immunodiagnosis of fascioliasis, using a highly sensitive and specific sandwich ELISA technique. PMID:23961441

  13. A surface plasmon resonance assay for characterisation and epitope mapping of anti-GLP-1 antibodies.

    Science.gov (United States)

    Thomsen, Lasse; Gurevich, Leonid

    2018-04-19

    The incretin hormone glucagon-like peptide-1 (GLP-1) has been subject to substantial pharmaceutical research regarding the treatment of type 2 diabetes mellitus. However, quantification of GLP-1 levels remains complicated due to the low circulation concentration and concurrent existence of numerous metabolites, homologous peptides, and potentially introduced GLP-1 receptor agonists. Surface plasmon resonance (SPR) facilitates real-time monitoring allowing a more detailed characterisation of the interaction compared with conventional enzyme-linked immunosorbent assays (ELISA). In this paper, we describe the development of the first SPR assays for characterisation of anti-GLP-1 antibodies for ELISA purposes. Binding responses were obtained on covalently immobilised anti-GLP-1 antibodies at 12°C, 25°C, and 40°C and fitted to a biomolecular (1:1) interaction model showing association rates of 1.01 × 10 3 to 4.54 × 10 3  M -1  s -1 and dissociation rates of 3.56 × 10 -5 to 1.56 × 10 -3  s -1 leading to affinities of 35.2 to 344 nM, depending on the temperature. Determination of thermodynamic properties revealed an enthalpy driven interaction (ΔH polar amino acids (ΔC p  < 0). Pair-wise epitope mapping was performed on captured anti-GLP-1 antibodies followed by subsequent interaction with GLP-1 (7-36) and other anti-GLP-1 antibodies. A global evaluation of every binding response led to an epitope map elucidating the potential of various anti-GLP-1 antibody pairs for sandwich ELISA and hence pinpointing the optimal antibody combinations. The SPR assays proved capable of providing vital information for ELISA development endorsing it as a useful optimisation tool. Copyright © 2018 John Wiley & Sons, Ltd.

  14. Validation of an enzyme-linked immunosorbent assay (ELISA) for the measurement of canine S100A12.

    Science.gov (United States)

    Heilmann, Romy M; Cranford, Shannon M; Ambrus, Andy; Grützner, Niels; Schellenberg, Stefan; Ruaux, Craig G; Suchodolski, Jan S; Steiner, Jörg M

    2016-03-01

    Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs. © 2016 American Society for Veterinary Clinical Pathology.

  15. Detection of Foot-and-mouth Disease Serotype O by ELISA Using a Monoclonal Antibody

    OpenAIRE

    Chen, Hao-tai; Peng, Yun-hua; Zhang, Yong-guang; Liu, Xiang-tao

    2012-01-01

    An ELISA assay with monoclonal antibody (MELISA) was used to type serotype O of foot-and-mouth disease virus (FMDV). All FMDV serotype O reference strains were positive by MELISA, while other viruses such as FMDV serotypes Asia 1, C, and A and classical swine fever virus, swine vesicular disease virus, and porcine reproductive and respiratory syndrome virus remained negative. Furthermore, FMDV serotype O positive samples were able to be detected by MELISA. This assay may be particularly suita...

  16. Anti-double stranded DNA antibodies in systemic lupus erythematosus : Detection and clinical relevance of IgM-class antibodies

    NARCIS (Netherlands)

    Bootsma, H; Spronk, PE; Hummel, EJ; deBoer, G; terBorg, EJ; Limburg, PC; Kallenberg, CGM

    1996-01-01

    We determined the discriminative value of the Farr assay in comparison to ELISA and Crithidia luciliae immunofluorescence assay (IFT) for detecting anti-dsDNA antibodies as a diagnostic tool for systemic lupus erythematosus (SLE). Special attention was paid to the diagnostic significance of

  17. Increased specificity in human cardiac-myosin radioimmunoassay utilizing two monoclonal antibodies in a double sandwich assay

    International Nuclear Information System (INIS)

    Katus, H.A.; Hurrell, J.G.; Matsueda, G.R.; Ehrlich, P.; Zurawski, V.R. Jr.; Khaw, B.-A.; Haber, E.

    1982-01-01

    An immunoradiometric assay that simultaneously measured two different epitopes on the same molecule was devised to differential between cardiac- and skeletal-myosin light chains. Three monoclonal antibodies were examined that were 100% (lC5), 25% (2B9) and 17% (4F10) cross reactive, respectively, between the two antigens. One antibody of the pair to be studied was immobilized to cyanogen bromide-activated Sepharose 4B while the other was iodinated with 125 I using the lactoperoxidase method. The antigen was mixed with the immobilized antibody, the labeled antibody was added and the precipitate then washed and counted in a gamma counter. When both antibodies of the pair to be studied (immobilized and labeled) were the same (2B9), no radioactivity above background was bound to the precipitate, indicating that the second antibody could not bind to an already occupied epitope. When two different antibodies were employed, the specificity of the assay increased over that of a single antibody. The cross reactivity of a pair approximated the product of the cross reactivities of the individual antibodies. Thus, lC5 and 2B9 were 25% cross reactive together, lC5 and 4F10 17% cross reactive, and 2B9 and 4F10 4.3% cross reactive. (author)

  18. Control charts for identifying systematic errors using control sera to detect antibody to Salmonella in an indirect ELISA

    DEFF Research Database (Denmark)

    Bak, H.; Barfod, Kristen

    2008-01-01

    This study evaluated the preparation of Shewhart's control charts using the concept of rational subgroups for monitoring the Salmonella antibody ELISA used for surveillance of Danish pig herds. Control charts were prepared for a buffer control sample, a negative serum sample and a positive serum...

  19. Quality Control System for Beer Developed with Monoclonal Antibodies Specific to Barley Lipid Transfer Protein

    Directory of Open Access Journals (Sweden)

    Yukie Murakami-Yamaguchi

    2012-10-01

    Full Text Available Non-specific lipid transfer protein (LTP in barley grain reacted with the IgE in sera drawn from food allergy patients. A sandwich-type of enzyme-linked immunosorbent assay (ELISA was developed with mouse monoclonal antibodies raised against LTP purified with barley flour. This ELISA showed a practical working range of 0.3–3 ng/mL and no cross-reactivity with wheat, adlay and rye. Using this ELISA, LTP was determined in several types of barley-foods, including fermented foods such as malt vinegar, barley-malt miso and beer. LTP content in beer of the same kind was approximately constant, even if manufacturing factory and production days were different. Not only as a factor of foam formation and stability but also as an allergen, controlling and monitoring of LTP in beer should be considered. Taken together, our LTP-detecting ELISA can be proposed as an appropriate system for the quality control of beer.

  20. Validation of an indirect ELISA for the detection of Trypanosoma congolense antibodies in Ethiopian cattle

    International Nuclear Information System (INIS)

    Tadesse, Y.; Kefyalew, H.; Kembata, G.; Nega, A.

    2000-01-01

    Control and eradication of African Animal Trypanosomosis can be achieved if the reliability of the methods to diagnose the disease could be improved. The techniques currently used in the diagnosis of trypanosomosis in Ethiopia are not sufficiently sensitive to detect all infected animals. In order to improve disease diagnosis the indirect antibody detection ELISA, developed by FAO/IAEA, was evaluated under field conditions. Accordingly, reference serum samples were collected from trypanosomosis free and endemic areas. Serum samples negative for trypanosomes were collected from the Central highlands of Ethiopia where there is no previous record of trypanosomosis. The samples were used to establish the threshold and the specificity of the test. Trypanosoma congolense positive sera (based on thin and thick smears and BCT) were collected from endemic areas in the Southwestern part of the country to estimate the sensitivity of the test. Out of 701 negative serum samples, 690 were identified as negative with the indirect antibody ELISA, whereas the remaining 11 were detected as positive. Moreover, of the 282 infected samples the ELISA detected 155 sera as positive, but the remaining 127 cases fell in the negative range. The positive/negative threshold established from negative reference sera was found to be 81.38%. Based on this threshold the specificity of the test was 98.43%, whilst the sensitivity was calculated as 54.96%. Thus, the complementary use of both the ELISA and parasitological methods is encouraged. Since the internal quality controls (IQC) did not fall in the ranges prescribed in the protocol provided by FAO/IAEA precision was achieved by comparing the plate to plate variation of the IQC based on the means plot. Accordingly the assay process indicated that there was no significant difference between individual mean of each plate regarding the strong positive (C++) and moderate positive (C+) controls. Nevertheless, considerable discrepancies were

  1. Direct replacement of antibodies with molecularly imprinted polymer nanoparticles in ELISA--development of a novel assay for vancomycin.

    Science.gov (United States)

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J Sarah; Piletska, Elena V; De Vargas Sansalvador, Isabel M Perez; Whitcombe, Michael J; Piletsky, Sergey A

    2013-09-03

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop assays similar to the enzyme-linked immunosorbent assay (ELISA) is presented here for the first time. NanoMIPs were synthesized by a solid-phase approach with an immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering, and electron microscopy. Immobilization, blocking, and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a horseradish peroxidase-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range of 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was 3 orders of magnitude better than a previously described ELISA based on antibodies. In these experiments, nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA.

  2. AN EVALUATION STUDY OF ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA USING RECOMBINANT PROTEIN GRA1 FOR DETECTION OF IGG ANTIBODIES AGAINTS TOXOPLASMA GONDII INFECTIONS

    Directory of Open Access Journals (Sweden)

    Nina Difla Muflikhah

    2017-08-01

    Full Text Available Toxoplasmosis is an infectious disease caused by Toxoplasma gondii, an intracellular protozoan parasite that live inside the cells of the reticulo endothelial and parenchymal cells of human and animals (mammals and birds. Some cases of toxoplasmosis usually have no symptoms, but in any cases caused severe symptoms, such as hydrocephalus, microcephalus, intracranial calcification, retinal damage, brain abscess, mental retardation, lymphadenopathy, and others. Its severe symptoms usually showed a long time after first exposure, except symptoms showed by congenital transmission caused by infected mother. Early diagnosis is important to prevent the illness but methods for toxoplasmosis screening are still too expensive for developing country. Enzyme-linked immunosorbent assay (ELISA allow the testing of a large number samples within short time frame and based on antibody or antigen detection. This study aimed to know the sensitivity and specificity of recombinat protein GRA1 as antigen using ELISA methods. We tested the sensitivity and spesificity of GRA1 protein as antigen in ELISA methods to diagnose toxoplasmosis and compared with ELISA Kit Commercial. Reliable laboratory testing is important to detect Toxoplasma gondii infection, and focused to improving the low cost and easy-to-use diagnostic instrument. Seventy sera collected and tested using both indirect ELISA, commercial ELISA kit and GRA1 protein coated as antigen. Fourty eight and fifty one samples showed positive IgG antibody result of ELISA-GRA1 and ELISA kit. Negative sample tested by ELISA-GRA1 was 22 samples and 19 sample tested by ELISA Kit. The sensitivity and specificity of GRA1-based on ELISA were 100% and 86.36%, positive prediction value (ppv was 94.11%. These data indicate that the recombinant protein GRA1 is a highly immunogenic protein in human toxoplasmosis and become a promising marker for the screening of toxoplasmosis.

  3. Development and evaluation of a competitive ELISA using a monoclonal antibody for antibody detection after goose parvovirus virus-like particles (VLPs) and vaccine immunization in goose sera.

    Science.gov (United States)

    Wang, Qian; Ju, Huanyu; Li, Yanwei; Jing, Zhiqiang; Guo, Lu; Zhao, Yu; Ma, Bo; Gao, Mingchun; Zhang, Wenlong; Wang, Junwei

    2014-12-01

    An assay protocol based on a monoclonal antibody-based competitive enzyme-linked immunosorbent assay (MAb-based C-ELISA) for detecting antibodies against goose parvovirus (GPV) and its virus-like particles (VLPs) is described. The assay was developed using baculovirus-expressed recombinant VP2 virus-like particles (rVP2-VLPs) as antigens and a monoclonal antibody against GPV as the competitive antibody. Of the four anti-GPV MAbs that were screened, MAb 1G3 was selected as it was blocked by the GPV positive serum. Based on the distribution of percent inhibition (PI) of the known negative sera (n=225), a cut-off value was set at 36% inhibition. Using this cut-off value, the sensitivity of the assay was 93.3% and the specificity was 95.8%, as compared with the gold standard (virus neutralization assay). The rVP2-VLPs did not react with anti-sera to other goose pathogens, indicating that it is specific for the recognization of goose parvovirus antibodies. The assay was then validated with serum samples from goslings vaccinated with several VLPs (rVP1-VLPs, rVP2-VLPs, rVP3-VLPs, and rCGV-VLPs) and other vaccines (inactivated and attenuated). The C-ELISA described in this study is a sensitive and specific diagnostic test and should have wide applications for the sero-diagnosis and immunologic surveillance of GPV. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Development of ELISA-detected anti-HLA antibodies precedes the development of bronchiolitis obliterans syndrome and correlates with progressive decline in pulmonary function after lung transplantation.

    Science.gov (United States)

    Jaramillo, A; Smith, M A; Phelan, D; Sundaresan, S; Trulock, E P; Lynch, J P; Cooper, J D; Patterson, G A; Mohanakumar, T

    1999-04-27

    Development of anti-HLA antibodies after lung transplantation (LT) is thought to play an important role in the etiology of bronchiolitis obliterans syndrome (BOS). However, a cause-effect relationship between anti-HLA antibodies and BOS has not been established. This study was conducted to determine the temporal relationship between the development of anti-HLA antibodies and BOS after LT, and to determine the antigenic specificity of the antibodies developed in BOS patients. Sera from 15 BOS+ LT patients and 12 BOS- LT patients were obtained before LT and collected again at 6, 12, 24, 36, and 48 months after LT. Anti-HLA antibodies were detected by the PRA-STAT ELISA system and by complement-dependent cytotoxicity assays. Anti-HLA reactivity was further characterized by flow cytometry and absorption/elution with human platelets. When analyzed by ELISA, 10 of 15 BOS+ patients developed anti-HLA antibodies, whereas 0 of 12 BOS- patients developed anti-HLA antibodies (PELISA after LT can provide an early identification of an important subset of LT patients with an increased risk of developing BOS.

  5. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    Science.gov (United States)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  6. A Simple and Specific Noncompetitive ELISA Method for HT-2 Toxin Detection

    Directory of Open Access Journals (Sweden)

    Henri O. Arola

    2017-04-01

    Full Text Available We developed an HT-2 toxin-specific simple ELISA format with a positive read-out. The assay is based on an anti-immune complex (IC scFv antibody fragment, which is genetically fused with alkaline phosphatase (AP. The anti-IC antibody specifically recognizes the IC between a primary anti-HT-2 toxin Fab fragment and an HT-2 toxin molecule. In the IC ELISA format, the sample is added together with the scFv-AP antibody to the ELISA plate coated with the primary antibody. After 15 min of incubation and a washing step, the ELISA response is read. A competitive ELISA including only the primary antibody recognizes both HT-2 and T-2 toxins. The anti-IC antibody makes the assay specific for HT-2 toxin, and the IC ELISA is over 10 times more sensitive compared to the competitive assay. Three different naturally contaminated matrices: wheat, barley and oats, were used to evaluate the assay performance with real samples. The corresponding limits of detection were 0.3 ng/mL (13 µg/kg, 0.1 ng/mL (4 µg/kg and 0.3 ng/mL (16 µg/kg, respectively. The IC ELISA can be used for screening HT-2 toxin specifically and in relevant concentration ranges from all three tested grain matrices.

  7. Detection of Double White Dwarf Binaries with Gaia, LSST and eLISA

    Science.gov (United States)

    Korol, V.; Rossi, E. M.; Groot, P. J.

    2017-03-01

    According to simulations around 108 double degenerate white dwarf binaries are expected to be present in the Milky Way. Due to their intrinsic faintness, the detection of these systems is a challenge, and the total number of detected sources so far amounts only to a few tens. This will change in the next two decades with the advent of Gaia, the LSST and eLISA. We present an estimation of how many compact DWDs with orbital periods less than a few hours we will be able to detect 1) through electromagnetic radiation with Gaia and LSST and 2) through gravitational wave radiation with eLISA. We find that the sample of simultaneous electromagnetic and gravitational waves detections is expected to be substantial, and will provide us a powerful tool for probing the white dwarf astrophysics and the structure of the Milky Way, letting us into the era of multi-messenger astronomy for these sources.

  8. (ELISA) kit for diagnosis copro-antigens of Giardia lamblia

    African Journals Online (AJOL)

    STORAGESEVER

    2010-08-02

    Aug 2, 2010 ... methods based on antigen scanning of parasites such as enzyme linked immunosorbent assay (ELISA), ... samples. To design this method, a pure antibody against parasite as well as an antibody conjugated to a ..... school children in Santiago, Chile by capture ELISA for the detection of fecal Giardia ...

  9. [Enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Salmonella Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in persons from outbreak of typhoid fever].

    Science.gov (United States)

    Rastawicki, Waldemar; Kałużewski, Stanisław

    2015-01-01

    The laboratory diagnosis of typhoid fever is dependent upon either isolation of S. Typhi from a clinical sample or the detection of raised titers of serum antibodies in the Widal test or the passive hemagglutination assay (PHA). In this study we evaluated the usefulness of ELISA for detection of antibodies to S. Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in the sera of persons from outbreak of typhoid fever. Fifteen serum samples from patients with laboratory confirmed typhoid fever and 140 sera from persons suspected for contact with typhoid fever patients from outbreak in 1974/75 in Poland were tested by ELISA. Additionally, as the control group, we tested 115 sera from blood donors for the presence of S. Typhi anti-LPS and anti-Vi antibodies. Anti-LPS and anti-Vi antibodies were detected in 80% and 53.3% of sera obtained from patients with laboratory confirmed typhoid fever, respectively. The high percentages of positive results in ELISA were also noted in the group of persons suspected for contact with typhoid fever patients (51.4% and 45%) but not in the group of blood donors (7.8% and 6.1%, respectively). The ELISA could be a useful tool for the serological diagnosis of typhoid fever in patients who have clinical symptoms but are culture negative, especially during massive outbreaks of typhoid fever.

  10. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc

    Science.gov (United States)

    Thiha, Aung; Ibrahim, Fatimah

    2015-01-01

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings. PMID:25993517

  11. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc.

    Science.gov (United States)

    Thiha, Aung; Ibrahim, Fatimah

    2015-05-18

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.

  12. Direct replacement of antibodies with molecularly imprinted polymer (MIP) nanoparticles in ELISA – development of a novel assay for vancomycin

    Science.gov (United States)

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J. Sarah; Piletska, Elena V.; Perez De Vargas Sansalvador, Isabel M.; Whitcombe, Michael J.; Piletsky, Sergey A.

    2016-01-01

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop ELISA type assays is presented here for the first time. NanoMIPs were synthesized by a solid phase approach with immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering and electron microscopy. Immobilization, blocking and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a HRP-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was three orders of magnitude better than a previously described ELISA based on antibodies. In these experiments nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA. PMID:23947402

  13. Use of commercially available rabbit monoclonal antibodies for immunofluorescence double staining

    DEFF Research Database (Denmark)

    Bzorek, M.; Stamp, I.M.; Frederiksen, L.

    2008-01-01

    Immunohistochemistry, that is, the use of polyclonal and monoclonal antibodies to detect cell and tissue antigens at a microscopical level is a powerful tool for both research and diagnostic purposes. Especially in the field of hematologic disease, there is often a need to detect several antigens...... synchronously, and we report here a fast and easy technique for demonstrating more than 1 antigen in 1 slide using immunofluorescence. We have used commercially available rabbit monoclonal antibodies (Cyclin D1, CD3, CD5, CD23, etc.) paired with mouse monoclonal antibodies (CD7, CD20, CD79a, Pax-5, etc.......) for double immunofluorescence labeling on paraffin-embedded tissue sections. Commercially available rabbit monoclonal antibodies in combination with mouse monoclonal antibodies proved useful in double immunofluorescence labeling on paraffin-embedded tissue, and all combinations used yielded excellent results...

  14. Indication of viruses and virus-specific antibodies by ELISA using conjugates based on β-lactamase obtained by genetic engineering

    International Nuclear Information System (INIS)

    Kharitonenkov, I.G.; Kordym, V.A.; Khristova, M.L.; Leonov, S.V.; Kirillova, V.S.; Chernykh, S.I.

    1987-01-01

    The method of enzyme-linked immunosorbent assay (ELISA), by means of which antigens and antibodies of different origin can be detected with high sensitivity and specificity, is an immunoenzymatic technique based on the use of conjugates, or macromolecular complexes formed by covalent attachment of enzyme molecules to antigen or antibody molecules. Conjugates based on peroxidase, alkaline phosphatase, and beta-galactosidase are most frequently used to construct immunoenzymatic test systems. The use of these enzymes in ELISA, however, is complicated by the fact that they are often present in free or bound form in the biological material under study, and that their substrates either possess low stability, are difficult to synthesize, or are toxic. In this paper, in order to avoid these shortcomings, the authors develop a method for the biosynthesis of lactamase conjugates which is based on genetic engineering, and demonstrate the viability and stability of these conjugates in radioimmunoenzymatic assay of viruses

  15. An ELISA for the quantitation of von Willebrand Factor

    DEFF Research Database (Denmark)

    Vinholt, Pernille Just; Overgaard, Martin; Diederichsen, Axel Cosmus Pyndt

    2013-01-01

    for measurement of von Willebrand factor-osteoprotegerin complex (VWF:OPG) in human plasma. Furthermore, the significance of VWF:OPG complex as a marker of cardiovascular disease (CVD) was evaluated. PATIENTS/METHODS: A sandwich ELISA for quantification of VWF:OPG was developed using a polyclonal rabbit anti...... with and without documented coronary calcification (total n=118). RESULTS AND CONCLUSIONS: The assay detected VWF:OPG complexes in human plasma, while no significant signal was observed when testing solutions containing VWF or recombinant OPG alone. Importantly, the ELISA assay was able to detect in vitro formed...

  16. Serum specimens with double HBsAg/HBsAb (s-system) or HBeAg/HBeAb (e-system) positive markers (by ELISA) cross-checked with RIA or ECLIA--a comparison

    International Nuclear Information System (INIS)

    Tao Hongqun; Li Xiaolong; Ye Wei

    2005-01-01

    Objective: To cross-check the unusually high double positive rate of s- or e-system tested with ELISA in sera specimens from hepatitis B patients with two other methods of assay (RIA or ECLIA). Methods: Double positive s- or e-system sera specimens (tested with ELISA) were randomly selected to be cross-checked with RIA or ECLIA. Results: The double positive rate in the specimens checked with RIA was only 31.8% for s-system and 3.37% for e- system. In the case of ECLIA, the double positive rate was 17.65% and 9.09% respectively. The results obtained with both RIA and ECLIA were significantly lower than the results with ELISA (P 0.05). Conclusion: The unusually high double positive rate of s- or e- system in HBVM detection with ELISA was due to false positiveness and results from RIA were more consistent with the results from ECLIA. (authors)

  17. HAHA--nothing to laugh about. Measuring the immunogenicity (human anti-human antibody response) induced by humanized monoclonal antibodies applying ELISA and SPR technology.

    Science.gov (United States)

    Nechansky, Andreas

    2010-01-05

    Immunogenicity induced by passively applied proteins is a serious issue because it is directly related to the patient's safety. The out-come of an immune reaction to a therapeutic protein can range from transient appearance of antibodies without any clinical significance to severe life threatening conditions. Within this article, enzyme-linked immunosorbent assay (ELISA) and surface plasmon resonance (SPR) methodology to measure immunogenicity are compared and the pros and cons are discussed.

  18. Detection of ciguatoxin in fish tissue using sandwich ELISA and neuroblastoma cell bioassay.

    Science.gov (United States)

    Empey Campora, Cara; Dierking, Jan; Tamaru, Clyde S; Hokama, Yoshitsugi; Vincent, Douglas

    2008-01-01

    The applicability of a new enzyme-linked immunoassay (ELISA) for detecting ciguatoxin (CTX) in fish tissue was evaluated by testing three fish species commonly implicated in ciguatera fish poisoning in Hawaii. A total of 164 individual almaco jack (Seriola rivoliana) and greater amberjack (S. dumerili) and a total of 175 individuals of the blue-spotted grouper (Cephalopholis argus) were caught at various locations in the Hawaiian Islands. Muscle tissue from each individual was assessed for the presence of CTX using two methods: a semi-quantitative ELISA that was recently developed for detecting picogram levels of CTX in fish extract and a neuroblastoma (NB) cell assay commonly used to screen for marine toxins in fish. Results of the tests were highly correlated, with the ELISA indicating the presence of CTX in 9.4% of all fish samples, and the NB assay indicating toxicity in 6.8% of the fish samples. We conclude that the ELISA produces reliable and accurate results that are consistent with those provided by the accepted NB assay and that the ELISA has potential for future applications in screening fish populations for CTX.

  19. Development and evaluation of a truncated recombinant NS3 antigen-based indirect ELISA for detection of pestivirus antibodies in sheep and goats.

    Science.gov (United States)

    Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya

    2015-01-01

    The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.

  20. Validation of a foot-and-mouth disease antibody ELISA in five Latin American countries

    International Nuclear Information System (INIS)

    Sondahl, M.S.; Penha Dias Gomes, M. da; Aurnheimer Martins, M.; Washington Lopez, J.

    1998-01-01

    The work plan consisted of using a liquid phase blocking ELISA test for the detection of antibodies to foot-and-mouth disease virus (FMDV) using the following categories of sera: (A) Spot test 120 non-infected/non-vaccinated bovine sera diluted 1:32; (B) Titration test: 120 bovine sera from animals vaccinated with trivalent oil vaccine, bled 30 days after vaccination; (C) Titration test with sera from non-infected/non-vaccinated bovines that presented titers >1:32 in the spot test. To detect FMD positive animals in the field, the spot test established with a cut-off of 1: 32 demonstrated in this work a good specificity with the non-vaccinated group, where 3 animals out of 120 were considered positive. The antibody titration test is an excellent tool to determine the level of antibodies in cattle populations. The protocol indicates that positive sera from the spot test should be tested in the titration assay in a starting dilution of 1:32. We suggest to use a lower starting dilution (1:16) in order to start below the discriminative of positive spot test sera 1:32 for the titration assay procedures. (author)

  1. [The comparison of two newborn cytomegalovirus IgG antibody screening ELISA kits].

    Science.gov (United States)

    Zhang, Shun-Xian; He, Xiao-Zhou; Wang, Shi-Wen; Wang, Xiao-Fang

    2013-10-01

    This study compared two newborn Cytomegalovirus (CMV) IgG antibody screening ELISA kits and evaluated the detection effectiveness of Abnova kit. CMV IgG antibodies were detected by both SeraQuest and Abnova kits from dried blood spot (DBS) samples of 488 newborn heel sticks. The detection abilities of these two kits were compared in different sample dilution concentrations. Relative detection effectiveness of the Abnova kit was defined by statistical method using the SeraQuest kit as a point of comparison. Compared to the SeraQuest screening test kit, the Abnova kit revealed a sensitivity of 98.9%, specificity of 78.6%, positive predictive value of 99.3%, negative predictive value of 68.8%, and the coincidence rate for these two screening test kits at 98.3%. The consistency check of both kits based on interpretation of the kappa statistic was relatively good. For the Abnova kit, the "area under the ROC curve" was 0.887, which indicates moderate accuracy. Abnova kit can be applied to newborn screening for congenital CMV infections. However, repeating the test for ambiguous results is suggested to increase the specificity and negative predictive value.

  2. Development of sandwich enzyme-linked immunosorbent assay systems for plasma β-galactoside α2,6-sialyltransferase, a possible hepatic disease biomarker

    International Nuclear Information System (INIS)

    Futakawa, Satoshi; Kitazume, Shinobu; Oka, Ritsuko; Ogawa, Kazuko; Hagiwara, Yoshiaki; Kinoshita, Akinori; Miyashita, Kazuya; Hashimoto, Yasuhiro

    2009-01-01

    Previous reports, including our work, have shown that plasma β-galactoside α2,6-sialyltransferase (ST6Gal I) activity is significantly increased in particular hepatopathological situations, suggesting that it may represent a sensitive biomarker for diagnosing hepatic diseases. So far, activity of ST6Gal I have been measured by using radioactive tracer method in place of measuring amount of ST6Gal I. However, this method is tangled and cannot exclude other sialyltransferase activities. Thus, simple and specific methods for measuring plasma ST6Gal I had been unavailable. Here, we developed two kinds of sandwich enzyme-linked immunosorbent assay (ELISA) systems that specifically detect the soluble cleaved form of ST6Gal I in plasma. In one sandwich ELISA, we detected rat specific sequence, EFQMPK, which is N-terminus of soluble ST6Gal I. In the other sandwich ELISA, we detected internal common sequence among rat, mouse and human ST6Gal I in plasma (M2 ELISA). Using the M2 ELISA, we observed that elevation of plasma ST6Gal I was much faster than elevation of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in a carbon tetrachloride (CCl 4 )-induced mouse liver injury model. Our data suggest that these ELISA systems are very useful tools for measuring plasma ST6Gal I, which represents a potential biomarker for diagnosing hepatic diseases

  3. Development of sandwich enzyme-linked immunosorbent assay systems for plasma {beta}-galactoside {alpha}2,6-sialyltransferase, a possible hepatic disease biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Futakawa, Satoshi [Department of Biochemistry, School of Medicine, Fukushima Medical University, 1 Hikarigaoka, Fukushima-shi, Fukushima 960-1295 (Japan); Kitazume, Shinobu [Disease Glycomics Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Oka, Ritsuko [CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Glyco-chain Functions Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); Ogawa, Kazuko [Disease Glycomics Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Hagiwara, Yoshiaki; Kinoshita, Akinori; Miyashita, Kazuya [Department of Biological Sciences, Immuno-Biological Laboratories Co. Ltd., 1091-1 Naka, Fujioka-shi, Gunma 375-0005 (Japan); Hashimoto, Yasuhiro [Department of Biochemistry, School of Medicine, Fukushima Medical University, 1 Hikarigaoka, Fukushima-shi, Fukushima 960-1295 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan)], E-mail: yasuc@fmu.ac.jp

    2009-01-05

    Previous reports, including our work, have shown that plasma {beta}-galactoside {alpha}2,6-sialyltransferase (ST6Gal I) activity is significantly increased in particular hepatopathological situations, suggesting that it may represent a sensitive biomarker for diagnosing hepatic diseases. So far, activity of ST6Gal I have been measured by using radioactive tracer method in place of measuring amount of ST6Gal I. However, this method is tangled and cannot exclude other sialyltransferase activities. Thus, simple and specific methods for measuring plasma ST6Gal I had been unavailable. Here, we developed two kinds of sandwich enzyme-linked immunosorbent assay (ELISA) systems that specifically detect the soluble cleaved form of ST6Gal I in plasma. In one sandwich ELISA, we detected rat specific sequence, EFQMPK, which is N-terminus of soluble ST6Gal I. In the other sandwich ELISA, we detected internal common sequence among rat, mouse and human ST6Gal I in plasma (M2 ELISA). Using the M2 ELISA, we observed that elevation of plasma ST6Gal I was much faster than elevation of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in a carbon tetrachloride (CCl{sub 4})-induced mouse liver injury model. Our data suggest that these ELISA systems are very useful tools for measuring plasma ST6Gal I, which represents a potential biomarker for diagnosing hepatic diseases.

  4. A new type of natural bispecific antibody with potential protective effect in Hashimoto thyroiditis.

    Science.gov (United States)

    Li, Wenli; Fan, Gaowei; Chen, Lida; Zhang, Rui; Zhang, Kuo; Sun, Yu; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming

    2014-09-01

    As a new antibody concept, natural bispecific antibodies (nBsAbs) have been detected in long-term passive immunization and some diseases, but their potential immunomodulatory role remains unclear. Hashimoto thyroiditis (HT) appears to fulfill the condition for nBsAb production but has not yet been characterized. The objective of the study was to identify a new nBsAb against thyroid peroxidase (TPO) and thyroglobulin (Tg) in HT patients and to preliminarily explore its immunomodulatory role. Serum samples were obtained from 136 HT patients, 92 diseased controls, and 99 healthy controls for anti-TPO/Tg nBsAb detection. The relationship between anti-TPO/Tg nBsAb and other clinical parameters was also analyzed. The anti-TPO/Tg nBsAb was detected using a double-antigen sandwich ELISA. Higher nBsAb levels were found to be associated with decreased inflammation in HT patients. The prevalence of anti-TPO/Tg nBsAb in HT was 44.9% (61 of 136), significantly higher than that of diseased controls (2.2%, 2 of 92) (P thyroiditis patients. A new type of nBsAb against TPO and Tg in HT patients is identified. Our data also indicate a protective effect of anti-TPO/Tg nBsAb in the pathogenesis of HT and extend prior knowledge about nBsAb in diseases.

  5. Comparison of a commercial ELISA and an immunoperoxidase monolayer assay to detect antibodies directed against porcine respiratory and reproductive syndrome virus

    NARCIS (Netherlands)

    Nodelijk, G.; Wensvoort, G.; Kroese, B.; Leengoed, van L.A.M.G.; Colijn, E.; Verheijden, J.H.M.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against porcine respiratory and reproductive syndrome virus (PRRSV) was compared to an immunoperoxidase monolayer assay (IPMA). Serum samples used were collected from pigs experimentally infected with

  6. The use of enzyme-linked immunosorbent assay (ELISA) for the diagnosis and monitoring of foot-and-mouth disease in the Philippines

    International Nuclear Information System (INIS)

    Verin, B.C.; Arvesu, R.M.

    2000-01-01

    The establishment and use of the indirect sandwich ELISA for the detection of foot-and-mouth disease (FMD) virus antigen sero-types O, A and C and the liquid phase blocking ELISA (LPB-ELISA) for antibody levels against similar FMD sero-types has been adopted for routine diagnosis at the FMD diagnostic laboratory, PAHC. A total of 552 epithelial samples and 4401 serum samples were tested starting 1995 to 1998. Out of 552, 84 (17.9%) were found negative and 468 (84.78%) diagnosed as positive for sero-types O and C (42% of the total positives). Within 4 years, 62 representative samples were sent to WRL for FMD for confirmation diagnosis. From 62 samples sent 54 (87%) were diagnosed as positive and 8 (12.9%) were negative. Serum samples received were either for diagnosis (71 samples), surveillance (3002 serum), post vaccination titre (1303 serum) and for the FAO/IAEA external quality assurance programme (25 samples) by the FAO/IAEA Co-ordinated Research Project on FMD. The assay has been a useful tool in the fast diagnosis and confirmation of FMD suspect cases and in the measurement of antibodies against FMDV in serum samples from all animals either vaccinated or infected. In the future, the assay will be use for potency testing of imported vaccines and for monitoring and surveillance purposes to show freedom from disease for the support documentation from OIE. (author)

  7. Study of FAO/IAEA/PANAFTOSA ELISA kit for the detection of antibodies against FMD

    International Nuclear Information System (INIS)

    Ravison, J.A.; Andrade Goncalves, D. de; Souza, R. de

    1998-01-01

    Two groups of sera were used to evaluate a liquid phase blocking ELISA (LPBE) for the detection of antibody against foot-and-mouth disease virus. One hundred and twenty sera, from animals with no previous history of FMD infection or vaccination, were analyzed by screening assay at a final dilution of 1:32. A second group of 120 sera, from animals vaccinated with an oil trivalent vaccine (O, A, C) were tested by titration in the LPBE. All the sera were tested against virus of three FMD serotypes, using O 1 Campos, A 24 Cruzeiro, C 3 Indaial virus strains. (author)

  8. Detection and confirmation of PPR virus antigen in sheep and goats by sandwich-ELISA and RT-PCR in Andhra Pradesh, India

    Directory of Open Access Journals (Sweden)

    G. Saritha

    2015-06-01

    Full Text Available Peste des petits ruminants (PPR is a highly contagious disease of domestic and wild small ruminants. Rapid and accurate laboratory assay are essential to enable the implementation of appropriate control strategies to restrict the spread of PPR. The present study was designed to detect the PPR virus (PPRV antigen (N-gene in nasal swabs and tissue samples. A total of 195 samples comprising of 138 nasal swabs from PPR suspected sheep (n=72 and goats (n=66, and 57 tissue samples comprising of lymph nodes from dead sheep (n=39 and goats (n=18 were collected from certain parts of Andhra Pradesh. The samples were subjected to sandwich-ELISA followed by RT-PCR for confirmatory diagnosis. In this study, PPRV could be detected in 27.53% (n=38/138 nasal swabs and 49.12% (n=28/57 tissue samples. Data showed that PPRV infection is widespread in the Andhra Pradesh, India.

  9. Evaluation of an enzyme linked immunosorbent assay kit for the detection of Babesia bovis antibodies in cattle in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Echaide, S; Echaide, I E; Mangold, A J; Lugaresi, C I; Guglielmone, A A [Estacion Experimental Agropecuaria, Instituto Nacional de Tecnologia Agropecuaria, Rafaela, Santa Fe (Argentina); Gaido, A B [Estacion Experimental Agropecuaria Salta, Salta (Argentina)

    1998-11-01

    An enzyme linked immunosorbent assay (ELISA) for the detection of antibodies to Babesia bovis was evaluated by using sera of 874 cattle carrying B. bovis antibodies, 700 sera of uninfected cattle, and 357 sera from calves from 16 herds subjected to different B. bovis inoculation rates. The seropositive/ seronegative cut-off point set as double the mean percent positivity of negative cattle sera (= 16%). The sensitivity of the ELISA (four trials) ranged from 97.1% to 100% and the specificity (three trials) varied from 92.0% to 97.0%. The agreement between ELISA and immunofluorescent antibody test was {>=} 90.0% in 18 of 23 evaluations and it ranged from 86.0% to 88.0% in the remainder. The correlation coefficient between percentage of sera positive to ELISA and IFA test in 16 herds was 0.9958 (P<0.001). The ELISA has the advantages of a high sensitivity, objectivity and capacity to test large number of samples in short period of time and could replace the IFA test specially for epidemiological studies. (author) 11 refs, 1 fig., 2 tabs

  10. Evaluation of an enzyme linked immunosorbent assay kit for the detection of Babesia bovis antibodies in cattle in Argentina

    International Nuclear Information System (INIS)

    Echaide, S.; Echaide, I.E.; Mangold, A.J.; Lugaresi, C.I.; Guglielmone, A.A.; Gaido, A.B.

    1998-01-01

    An enzyme linked immunosorbent assay (ELISA) for the detection of antibodies to Babesia bovis was evaluated by using sera of 874 cattle carrying B. bovis antibodies, 700 sera of uninfected cattle, and 357 sera from calves from 16 herds subjected to different B. bovis inoculation rates. The seropositive/ seronegative cut-off point set as double the mean percent positivity of negative cattle sera (= 16%). The sensitivity of the ELISA (four trials) ranged from 97.1% to 100% and the specificity (three trials) varied from 92.0% to 97.0%. The agreement between ELISA and immunofluorescent antibody test was ≥ 90.0% in 18 of 23 evaluations and it ranged from 86.0% to 88.0% in the remainder. The correlation coefficient between percentage of sera positive to ELISA and IFA test in 16 herds was 0.9958 (P<0.001). The ELISA has the advantages of a high sensitivity, objectivity and capacity to test large number of samples in short period of time and could replace the IFA test specially for epidemiological studies. (author)

  11. A Sandwich HIV p24 Amperometric Immunosensor Based on a Direct Gold Electroplating-Modified Electrode

    Directory of Open Access Journals (Sweden)

    Ning Gan

    2012-05-01

    Full Text Available Acquired immune deficiency syndrome (AIDS is a severe communicable immune deficiency disease caused by the human immune deficiency virus (HIV. The analysis laboratory diagnosis of HIV infection is a crucial aspect of controlling AIDS. The p24 antigen, the HIV-1 capsid protein, is of considerable diagnostic interest because it is detectable several days earlier than host-generated HIV antibodies following HIV exposure. We present herein a new sandwich HIV p24 immunosensor based on directly electroplating an electrode surface with gold nanoparticles using chronoamperometry, which greatly increased the conductivity and reversibility of the electrode. Under optimum conditions, the electrochemical signal showed a linear relationship with the concentration of p24, ranging from 0.01 ng/mL to 100 ng/mL (R > 0.99, and the detection limit was 0.008 ng/mL. Compared with ELISA, this method increased the sensitivity by more than two orders of magnitude (the sensitivity of ELISA for p24 is about 1 ng/mL. This immunosensor may be broadly applied to clinical samples, being distinguished by its ease of use, mild reaction conditions, guaranteed reproducibility, and good anti-interference ability.

  12. A sandwich HIV p24 amperometric immunosensor based on a direct gold electroplating-modified electrode.

    Science.gov (United States)

    Zheng, Lei; Jia, Liyong; Li, Bo; Situ, Bo; Liu, Qinlan; Wang, Qian; Gan, Ning

    2012-05-18

    Acquired immune deficiency syndrome (AIDS) is a severe communicable immune deficiency disease caused by the human immune deficiency virus (HIV). The analysis laboratory diagnosis of HIV infection is a crucial aspect of controlling AIDS. The p24 antigen, the HIV-1 capsid protein, is of considerable diagnostic interest because it is detectable several days earlier than host-generated HIV antibodies following HIV exposure. We present herein a new sandwich HIV p24 immunosensor based on directly electroplating an electrode surface with gold nanoparticles using chronoamperometry, which greatly increased the conductivity and reversibility of the electrode. Under optimum conditions, the electrochemical signal showed a linear relationship with the concentration of p24, ranging from 0.01 ng/mL to 100 ng/mL (R > 0.99), and the detection limit was 0.008 ng/mL. Compared with ELISA, this method increased the sensitivity by more than two orders of magnitude (the sensitivity of ELISA for p24 is about 1 ng/mL). This immunosensor may be broadly applied to clinical samples, being distinguished by its ease of use, mild reaction conditions, guaranteed reproducibility, and good anti-interference ability.

  13. Antibody index and specific antibody quotient in horses after intragastric administration of Sarcocystis neurona sporocysts.

    Science.gov (United States)

    Heskett, Katherine A; Mackay, Robert J

    2008-03-01

    To investigate the use of a specific antibody index (AI) that relates Sarcocystis neurona-specific IgG quotient (Q(SN)) to total IgG quotient (Q(IgG)) for the detection of the anti-S neurona antibody fraction of CNS origin in CSF samples obtained from horses after intragastric administration of S neurona sporocysts. 18 adult horses. 14 horses underwent intragastric inoculation (day 0) with S neurona sporocysts, and 4 horses remained unchallenged; blood and CSF samples were collected on days - 1 and 84. For purposes of another study, some challenged horses received intermittent administration of ponazuril (20 mg/kg, PO). Sarcocystis neurona-specific IgG concentrations in CSF (SN(CSF)) and plasma (SN(plasma)) were measured via a direct ELISA involving merozoite lysate antigen and reported as ELISA units (EUs; arbitrary units based on a nominal titer for undiluted immune plasma of 100,000 EUs/mL). Total IgG concentrations in CSF (IgG(CSF)) and plasma (IgG(plasma)) were quantified via a sandwich ELISA and a radial immunodiffusion assay, respectively; Q(SN), Q(IgG), and AI were calculated. Following sporocyst challenge, mean +/- SEM SN(CSF) and SN(plasma) increased significantly (from 8.8 +/- 1.0 EUs/mL to 270.0 +/- 112.7 EUs/mL and from 1,737 +/- 245 EUs/mL to 43,169 +/- 13,770 EUs/mL, respectively). Challenge did not affect total IgG concentration, Q(SN), Q(IgG), or AI. S neurona-specific IgG detected in CSF samples from sporocyst-challenged horses appeared to be extraneural in origin; thus, this experimental challenge may not reliably result in CNS infection. Calculation of a specific AI may have application to the diagnosis of S neurona-associated myeloencephalitis in horses.

  14. Detection of anti-tetanus toxoid antibody on modified polyacrylonitrile fibers.

    Science.gov (United States)

    Jain, Swati; Chattopadhyay, Sruti; Jackeray, Richa; Zainul Abid, C K V; Kumar, Manoj; Singh, Harpal

    2010-10-15

    Accurate determination of concentration of immunoglobulin (IgG) to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, immune competence in individual patients and to measure the prevalence of immunity in populations. Surface modified polyacrylonitrile (PAN) fibers were evaluated as a matrix to develop highly sensitive method for the detection of anti-tetanus antibody in a sandwich ELISA format. In the proposed method tetanus toxoid immobilized on modified PAN fibers was used to detect anti-tetanus antibody (raised in horse hence represented as horse anti-tetanus toxoid or HAT-Ab) with horse raddish peroxidase enzyme conjugated with Rabbit anti-Horse IgG (RAH-HRP) as the label within 2.5h. A sigmoidal pattern for the detection of different concentration of antibody ranging from 1.0 to 0.0001 IU mL(-1) was validated. The immunoassay recorded a very high sensitivity as concentration as low as 0.0005 IU mL(-1) of HAT-Ab was detected. The intra- and inter-assay precision for 3 parallel measurements of 0.01 and for 0.001 IU mL(-1) of antibody varied from 5.4% to 11% and 5.7% to 20% respectively. PAN fibers were also used to qualitatively access the presence of different level of anti-tetanus antibody spiked in human blood. Seroepidemiological studies to measure the immunity against tetanus were conducted with twenty-five human beings belonging to various age groups using modified PAN-ELISA. The sensitivity, specificity and the reproducibility of the developed immunoassay indicate the potential application of modified PAN fibers in the field of immunodiagnostics. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Insulin radioimmunoassay kit (125I) using polyethyleneglycol (PEG) and a double antibody separation method

    International Nuclear Information System (INIS)

    Borza, Virginia; Chariton, Delfina; Neacsu, Elena

    1997-01-01

    Insulin is a polypeptide hormone formed from proinsulin in the b-cells of the islets of Langerhans in the pancreas. It has a widespread effect on carbohydrate, lipid and protein metabolism. Diabetes mellitus is the result of an insulin deficiency brought about either by insufficient insulin secretion or by rapid insulin catabolism. The determination of the insulin level is important for differential etiologic diagnosis and subsequent therapy and prognosis. Insulin radioimmunoassay kit provides a sensitive, precise and specific assay for insulin concentration in serum. Standard and insulin in the patient sample compete with tracer for binding sites on an insulin antibody. The antigen-antibody combination, which forms during incubation time, will be separated from free insulin by different methods. The separation technique using the double antibody technique combined with Polyethyleneglycol (PEG) is presented. The results are compared with the separation method using PEG alone and with double antibody technique. Antiserum to insulin was produced in rats immunized with porcine insulin, while rabbits immunized with rat-g globulin were used as a source for the second antibody.The tested PEG was PEG 6000. The best results were obtained using the double antibody at a 1/50 dilution combined with 7.5 PEG solutions. The time for precipitating the antibody bound fraction by this technique was established to be 30 minutes. The results obtained using this method as separation technique for insulin - antibody complex were better than those obtained using the double antibody techniques or PEG as precipitating agent alone. (authors)

  16. Incorporation of the ELISA technique to determine antibody levels against foot-and-mouth disease

    International Nuclear Information System (INIS)

    Vergara, N.N.; Caballero, P.H.; Santiago Gonzalez Patino, S.; Orue, P.M.

    1998-01-01

    Two groups of sera were evaluated by a liquid phase blocking ELISA (LPBE) for the detection and quantification of foot-and-mouth disease (FMD) antibodies to serotypes O, A and C to assess the sensitivity and specificity of the assay. The first group consisted of 120 sera from non-infected and non-vaccinated cattle, which were tested by a screening assay at a fix dilution of 1/32. The second group consisted of 120 sera from cattle vaccinated with a trivalent (O, A and C) vaccine. Sera from this group were titrated in a five fold dilution range: 1/10, 1/50, 1/250 and 1/1250. (author)

  17. The external quality assurance programme (EQAP) for the FAO/IAEA antibody FMD ELISA in Southeast Asia

    International Nuclear Information System (INIS)

    Colling, A.

    2000-01-01

    The external quality assurance programme (EQAP) consists of three equally important items: the questionnaire, the monitoring of the internal quality control data and the external quality control test panel. The EQAP is conducted twice per year. The first round of the EQAP for the FAO/IAEA liquid phase blocking ELISA being used in Southeast Asia was carried out in 1995-1996. A total of 10 laboratories from Asia participated. The round consisted of three FMD sero-types (O, A and Asia) for both, the antigen and antibody ELISA. No interim report was produced, but results were communicated on an individual basis. The second round was initiated in late 1998. Participating laboratories were the same as in 1996. This time the EQA proficiency exercise consisted only of one sero-type (O 1 Manisa) for the FMD Antibody ELISA. The results of this round are presented in this report. All participants replied to this EQA exercise. Out of ten participants six laboratories returned all EQA components (EQC results, IQC data and questionnaire). Four laboratories did not return the complete set of the EQA panel. Three out of five EQC samples achieved an overall agreement of 100%. Two EQC samples were excluded from the evaluation because a minimum of 80% of agreement between participants was not achieved. In comparison to the reference values for the EQC samples as established by the World Reference Center (WRC), UK, the participating laboratories produced lower PI values for the three positive samples 2, 8 and 5 and higher PI values for the negative samples 10 and 9 resulting in a decreased binding ratio. Nevertheless results show that all laboratories are able to detect a strong positive sample and no equivocally result was obtained for the two negative samples. Weak positive sera close to the cut-off are problematical for a minority of the laboratories, which tested these samples negative. The closer the sample comes to the cut-off the less agreement between laboratories is reached

  18. Frequency of antiphospholipid antibodies in patients with infectious diseases using three different ELISA methods Freqüência de anticorpos antifosfolípides em pacientes com doenças infecciosas usando três diferentes testes de ELISA

    Directory of Open Access Journals (Sweden)

    Mittermayer Barreto Santiago

    2006-02-01

    Full Text Available OBJECTIVE: The standard enzyme-linked immunosorbent assay (ELISA for anticardiolipin (aCL antibodies is the most important test for the diagnosis of antiphospholipid syndrome (APS. However, the test is also positive in some infectious diseases and other non-related syndromes. It has been suggested that the detection of antibodies to a mixture of phospholipids or to beta2-glycoprotein I (beta2-GP I has higher specificity for APS than the standard aCL ELISA. The aim of the present work is to compare the diagnostic specificity of three different antiphospholipid (aPL assays in patients with infectious diseases. METHODS: Antiphospholipid antibodies were searched by three ELISA techniques, namely standard aCL, APhL® ELISA kit and anti-beta2-GP I, in sera of patients with infectious diseases, including syphilis (69, leptospirosis (33 and visceral leishmaniasis (30. RESULTS: The frequency of positivity of IgG aPL in patients with syphilis, leptospirosis and Kala-azar was 13/69 (19%, 9/33 (27% and 2/30 (6%, respectively, using standard ELISA, versus only 1/69 (1.4%, 0/33 (0% and 0/30 (0% positivity by the APhL® ELISA kit. The positivity of the isotype IgM aPL was 10/69 (14%, 4/33 (12% and 1/30 (3%, respectively, by the standard ELISA, and 1/69 (1.4%, 0/33 (0% and 0/30 (0% by the APhL® ELISA kit. The presence of significant levels of IgG anti-beta2GPI was observed in 14/69 cases of syphilis (20%, 6/33 cases of leptospirosis (18% and 16/30 cases of Kala-azar (53%. The APhL® ELISA kit had superior performance showing the highest specificity: 97% (95% CI: 92%-99% for IgG compared to 81% (95% CI: 74%-87% for standard ELISA and 72% (95% CI: 64%-79% for anti-beta2 GPI assay. CONCLUSIONS: The APhL® ELISA kit proved to be significantly more specific than the aCL standard ELISA and the anti-beta2GPI ELISA, and it should be used to help in the diagnosis and confirmation of APS.OBJETIVO: O ensaio de enzyme-linked immunosorbent assay (ELISA para a pesquisa de

  19. [Identification and production of monoclonal antibody of Siberian tiger's immunoglobulin].

    Science.gov (United States)

    Zhang, Yaonglong; Zhang, Duanling; Zhou, Ming; Xue, Yuan; Hua, Yuping; Ma, Jianzhang

    2010-03-01

    To purify immunoglobulin (Ig) of Siberian Tiger and prepare monoclonal antibody (mAb) against the Ig,which can be used to develop immunological diagnostic kits for diagnosing infectious disease in Siberian Tiger. The Ig of Siberian tigers was purified with saturated ammonium sulfate combined with recombinant Protein G. The C57BL/6 mice were immunized with the purified Ig. Spleno-cytes of the mice immunized were collected and fused with the mouse myeloma cell line (Sp2/0-Ag14). The positive hybridoma clones were selected by ELISA and were identified by western blot. The sandwich ELISA was used to detect immunocompetence of the purified Ig and the mAb. We obtained three mouse hybridoma clones that produced mAbs against Ig of Siberian Tiger. The derived McAbs could recognize Ig heavy chain of Siberian Tiger specifically. The biological activity of the Ig and obtained McAbs also could be identified by detecting the antibody induced by panleukopenia virus (FPV-HLJ) vaccine in Siberian Tiger. The antibody also would be useful for assess the vaccine efficacy against the infectious disease on the Siberian Tiger. Protein G can be used in Ig purification of Siberian Tiger. The obtained McAbs from the hybridoma ADT11 in this study owned strong ability to bind Ig of Siberian Tiger and have a stable immunocompetence. They can be used to develop diagnostic methods for detecting infectious disease in Siberian Tiger and vaccine research.

  20. E.L.I.S.A. en coccidioidomicosis humana E.L.I.S.A. in human coccidioidomycosis

    Directory of Open Access Journals (Sweden)

    Iris Nora Tiraboschi

    1991-08-01

    Full Text Available Se realizó E.L.I.S.A. con exoantígeno de Coccidioides immitis para la detectión de anticuerpos, en 67 sueros humanos diluidos 1/1000, 1/2000, 1/4000 y 1/8000. De los 18 sueros de enfermos de coccidioidomicosis comprobada por examen directo, cultivo y/o histología, 5 fueron negativos, en otros 13 fueron positivos en una o varias diluciones. 3/26 sueros de personas sanas, coccidioidino positivas, fueron positivos en títulos de 1/1000 y el resto no tuvo anticuerpos detectables. No presentaron reacciones positivas ninguno de los sueros controles de personas sanas, pero sí lo hicieron 4/8 pacientes con otras micosis. Se concluye que E.L.I.S.A. es útil para la detección de mínimas cantidades de anticuerpos o en sueros que no pueden ser procesados por fijación de complemento. No es recomendable el uso de la técnica en forma aislada por al presencia de reacciones cruzadas.An E.L.I.S.A. test for antibody detection, with an exo-antigen of Coccidioides immitis was standardized in 67 humans sera diluited in 1/1000, 1/2000, 1/4000 and 1/8000. Eightheen sera from mycologically proved cases of coccidioidomycosis were studied: 5 were negative and 13 were positive in some dilutions. 3/26 sera of healthy persons who presented positive skin tests with coccidioidin were positive and the other 23 sera did not have positive reactions. None of the 15 sera of healthy human exhibited positive E.L.I.S.A. Serum samples of 8 patients suffering other deep mycosis were studied, 4 of them presented cross-reactions in E.L.I.S.A. tests. E.L.I.S.A. test seems to be a useful Serologic technique for antibody detection in anticomplementary serum samples or when a low concentration of antibodies should be detected. As it is very sensitive, cross-reactions with other mycoses are frequent, thus the use other more specific serologic technique together E.L.I.S.A. is recommended.

  1. Field validation of antibody ELISA's for diagnosis of bovine trypanosomosis and monitoring the efficacy of a tsetse and trypanosomosis control campaign in the agropastoral zone of Yale, Burkina Faso

    International Nuclear Information System (INIS)

    Bengaly, Z.; Sidibe, I.; Duvallet, G.

    2000-01-01

    Four trypanosomal antibody-detection-ELISA's systems based on the use of either native or denatured crude lysate antigens prepared from in-vitro propagated T. congolense bloodstream forms and in-vitro propagated T. vivax epimastigote forms, have been validated for their diagnostic performance and their utility for monitoring the efficacy of a tsetse and trypanosomosis control program. For that purpose, 600 samples of which 34 were parasite-positive, collected at different intervals in an area where tsetse eradication was implemented, were analysed. In addition, 200 sera from non-infected cattle in tsetse-free-area were also analysed. Except the native T. vivax antigen which showed high background and unreliable data, the three other ELISA assays were found acceptable for trypanosomal antibody detection. The cut-off values determined by doubling the mean of the known negative population were slightly lower than those obtained by visual analysis. The sensitivity ranged from 91% to 100% while the specificity was between 95% and 98% depending on the assay system used. For monitoring the efficacy of the tsetse control program, the other three antigens were found suitable but only denatured T. vivax antigens showed a significant decrease of the seroprevalence of T. vivax infection between the beginning and the end of the control program. The native and denatured T. congolense assay systems suggested that T. congolense infections might occur at a chronic stage and were being controlled by the cattle. (author)

  2. Utilisation of the buffy coat technique and an antibody-detection ELISA as tools for assessing the impact of trypanosomosis on health and productivity of N'Dama cattle

    International Nuclear Information System (INIS)

    Faye, J.A.; Mattioli, R.C.

    2000-01-01

    The buffy coat technique (BCT), a parasitological test, and an indirect antibody ELISA (Ab-ELISA) were used to detect trypanosome infections in blood and serum samples, respectively, collected on N'Dama cattle exposed to natural high tsetse challenge. These two diagnostic tools were also utilized to assess trypanosomal status in sequentially collected blood and serum samples from two groups composed of 5 N'Dama cattle each experimentally challenged with Trypanosoma congolense and T. vivax, In both studies, packed red cell volume (PCV) and live weight were measured. The specificity of the Ab-ELISA was computed by testing approximately 70 serum samples obtained from a cattle population kept under zero tsetse challenge. The specificity was found to be 95.8% for T. vivax and 97. 1 % for T. congolense. In the field study, 3.9% (12/310) of blood samples was parasitologically positive. In corresponding serum samples the prevalence of positive trypanosome sero-reactors was 54.8% (170/310). However, antibodies against trypanosomes persisted in serum when blood samples were no longer parasitologically positive. In both blood and serum samples, T. vivax was found to be the main infecting species. The sensitivity of the Ab-ELISA for T. vivax was 81.8%. Due to the extremely low numbers of T. congolense infection (only one), as detected by BCT, the sensitivity for that trypanosome species was not computed. In the experimentally challenged cattle, 80% (24/30) and 33.3% (10/30) of blood samples were BCT positive for T. congolense and T. vivax, respectively. Antibodies in corresponding sera were present in 69% (20/29) and 96.3% (26/27) of animals challenged with T. congolense and T. vivax, respectively. The serological assay for T. congolense antibody detection exhibited high cross-reactivity with T. vivax antigens, as assessed in sera collected from T. vivax infected animals. In the field study, cattle showing the presence of antibodies against T. congolense and/or T. vivax had

  3. Accuracy of a point-of-care ELISA test kit for predicting the presence of protective canine parvovirus and canine distemper virus antibody concentrations in dogs.

    Science.gov (United States)

    Litster, A L; Pressler, B; Volpe, A; Dubovi, E

    2012-08-01

    Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Sandwich immunoassay for alpha-fetoprotein in human sera using gold nanoparticle and magnetic bead labels along with resonance Rayleigh scattering readout

    International Nuclear Information System (INIS)

    Lu, Yao; Huang, Xiangyi; Ren, Jicun

    2013-01-01

    We describe a sensitive sandwich immunoassay for alpha-fetoprotein (AFP). It is making use of gold nanoparticles (GNPs) and magnetic beads (MBs) as labels, and of resonance Rayleigh scattering for detection. Two antibodies were labeled with GNPs and MBs, respectively, and MB-antigen-GNP complexes were formed in the presence of antigens. The MB labels also serve as solid phase carriers that can be used to magnetically separate the immuno complex. The GNP labels are used as optical probes, and Rayleigh scattering was used to determine the concentration of free GNPs-antibody after separation of the MB-antigen-GNP complexes. The concentration of AFP is related to the intensity of light scattered by free GNPs in the 13.6 pM to 436 pM concentration range, and the limit of detection is 13.6 pM. The method was applied to the determination of AFP in sera of cancer patients, and the results agree well with those obtained by conventional ELISA. (author)

  5. Comparison of Rose Bengal Plate Agglutination, Standard tube agglutination and Indirect ELISA tests for detection of Brucella antibodies in Cows and Buffaloes

    Directory of Open Access Journals (Sweden)

    S. N. Ghodasara

    2010-04-01

    Full Text Available A total of 180 serum samples (107 cows, 73 buffaloes from cases of abortion and various reproductive disorders were collected for detection of Brucella antibody by Rose Bengal Plate Agglutination Test (RBPT, Serum Tube Agglutination Test (STAT and indirect- ELISA (i-ELISA. The overall prevalence of brucellosis by RBPT, STAT and i-ELISA were 11.21%, 16.00% and 24.30% in cows 9.59%, 12.33% and 26.03% in buffaloes respectively. Overall seroprevalence of Brucellosis in cases of abortion, R.O.P. by RBPT, STAT and i-ELISA were 11.32%, 16.04% and 32.08% respectively. When three serological tests were compared, seropositivity was found highest by i-ELISA (25%, followed by STAT (14.45% and RBPT (10.56%. The results shows higher prevalence of brucellosis in cases of abortion and R.O.P., while at lower level from various reproductive disorders as detected serologically indicating endemicity of the infection in villages around Anand city, Gujarat. [Vet. World 2010; 3(2.000: 61-64

  6. Comparison of an enzyme linked immunosorbent assay (ELISA) and a radioallergosorbent test (RAST) for detection of IgE antibodies to Brugia malayi

    NARCIS (Netherlands)

    Wahyuni, Sitti; van Ree, Ronald; Mangali, Andarias; Supali, Taniawati; Yazdanbakhsh, Maria; Sartono, Erliyani

    2003-01-01

    The enzyme linked immunosorbent assay (ELISA) for specific IgE antibodies to Brugia malayi was compared with the radioallergosorbent test (RAST) for use in immunoepidemiological studies of lymphatic filariasis. Sera used were from individuals (aged 5-82 years) living in an area endemic for lymphatic

  7. Sandwich-dot enzyme-linked immunosorbent assay for the detection of canine distemper virus

    Science.gov (United States)

    Li, Zhi; Zhang, Yanlong; Wang, Huiguo; Jin, Jinhua; Li, Wenzhe

    2013-01-01

    A sandwich-dot enzyme-linked immunosorbent assay (dot ELISA) was developed for the detection of canine distemper virus (CDV). In 56 dogs suspected to have CD the rates of detection of CDV antigen in samples of blood lymphocytes and palpebral conjunctiva by dot ELISA and ELISA were, respectively, 91% (49/54) and 81% (44/54) for the lymphocyte samples and 88% (28/32) and 75% (24/32) for the conjunctival samples. The CDV detection limits were 10 ng/50 μL for dot ELISA and 40 ng/50 μL for ELISA. The reliability of dot ELISA relative to electron microscopy was 96% with 22 samples: all 21 samples in which CDV particles were observed by electron microscopy yielded positive results with dot ELISA; the single sample in which particles were not observed yielded false-positive results with dot ELISA. The results indicate that the dot ELISA developed can serve as a reliable rapid diagnostic test in suspected cases of CD and also be useful for epidemiologic surveillance of the disease. PMID:24124274

  8. A double antibody radioimmunoassay specific for placental alkaline phosphatase

    International Nuclear Information System (INIS)

    Dass, S.; Bagshawe, K.D.

    1984-01-01

    Placental alkaline phosphatase (PLAP) is normally found in enzymically measurable amounts in second and third trimester pregnancy serum. Its occurrence in sera and tumours from patients with malignant disease has led to the development of methods to specifically identify and quantitate the enzyme. Recently immunological techniques have been used, employing antibodies raised to purified PLAP; these include solid phase radioimmunoassays and enzyme-immunoassay. The development of a sensitive, specific, automated double-antibody radioimmunoassay for the measurement of PLAP in serum is reported. (Auth.)

  9. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    Science.gov (United States)

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. Toxoplasma gondii antibodies sheep in Lages, Santa Catarina, Brazil, and comparison using IFA and ELISA Anticorpos toxoplásmicos em ovinos de Lages, Santa Catarina, Brasil, e comparação utilizando RIFI e ELISA

    Directory of Open Access Journals (Sweden)

    Francine Bragagnolo Liz Stefen Sakata

    2012-09-01

    Full Text Available Toxoplasmosis in sheep is a disease of great importance in veterinary medicine, which causes economic losses in livestock and has a great impact on human health, since consumption of infected meat facilitates transmission of zoonotic infections. Blood samples from sheep (n = 360 were collected from 13 farm properties in the municipality of Lages, Santa Catarina, to estimate the prevalence of toxoplasmosis and identify risk factors associated with Toxoplasma gondii infection. T. gondii, antibodies were investigated by means of the indirect immunofluorescence assay (IFA and enzyme-linked immunosorbent assay (ELISA. Animals infected with T. gondii were found on 100% of the farms. IFA detected 56.9% (205/360 and ELISA 42.5% of the infected sheep. Breed was the only risk factor associated with the presence of T. gondii antibodies. ELISA showed sensitivity of 61%, specificity of 82% and kappa of 0.41, which was considered moderate. This allows use of ELISA as an alternative technique for diagnosing T. gondii in sheep.A toxoplasmose ovina é uma doença parasitária de elevada importância em medicina veterinária e em saúde pública, acarretando prejuízos na produção animal, gerados pelas perdas reprodutivas e econômicas, além de sua implicação na saúde humana, já que o consumo de carne infectada facilita a transmissão zoonótica. Para determinar a prevalência e identificar fatores de risco para a infecção por T. gondii em ovinos de Lages, Santa Catarina, amostras de sangue (n = 360 foram coletadas em 13 propriedades. Cada criador respondeu a um questionário para permitir a identificação dos fatores de risco da infecção. A pesquisa de anticorpos foi realizada por meio da Reação de Imunofluorescência Indireta (RIFI > 64 e do Ensaio Imunoenzimático Indireto (ELISA. Em 100% das propriedades foram encontrados animais positivos. Pela RIFI, 205 (56,94% ovinos apresentaram anticorpos contra T. gondii e pelo ELISA, 153 (42

  11. Antiphosphatidylserine/prothrombin antibodies as biomarkers to identify severe primary antiphospholipid syndrome.

    Science.gov (United States)

    Hoxha, Ariela; Mattia, Elena; Tonello, Marta; Grava, Chiara; Pengo, Vittorio; Ruffatti, Amelia

    2017-05-01

    Anti-phosphatidylserine/prothrombin (aPS/PT) antibodies have begun to be considered potentional biomarkers for antiphospholipid syndrome (APS). This cohort study investigate the role of aPS/PT antibodies as a risk factor for severe APS by evaluating the association between those antibodies and clinical/laboratory profiles of APS. Plasma/serum samples from 197 APS patients, 100 healthy subjects and 106 patients with autoimmune diseases were collected. IgG/IgM aPS/PT antibodies were assayed using commercial ELISA kit. Prevalences of IgG and IgM aPS/PT (pantiphospholipid antibody patients than in double and single positivity ones (p<0.0001 for all). APS/PT antibodies were associated to severe thrombosis, severe pregnancy complications inducing prematurity, and vascular microangiopathy, all generally associated to high risk APS forms requiring strong therapy.

  12. Field trial of brucellosis competitive ELISA

    International Nuclear Information System (INIS)

    Perez, B.; Rojas, M.

    1998-01-01

    2990 sera samples from cattle were tested for antibodies to Brucella abortus using 8 serological tests for. The tests used were Rose Bengal (RBT), Buffer Plate Agglutination Test (BPAT), Complement Fixation (CFT), 2 Indirect and 2 Competitive Enzyme Linked Immunosorbent Assays (ELISA). Bacteriological evaluation from milk was done also. All tests were compared with respect to diagnostic specificity in vaccinated herds which were considered to be Brucella-free. The diagnostic specificity of the Indirect and Competitive ELISA was greater than 99,8%. Estimates of relative sensitivity were obtained from infected herds. The diagnostic sensitivity of the Indirect ELISA was greater than 95,8% and for the Competitive ELISA between 98,8 and 100 %, the last value refers to the Competitive ELISA Prototype II (SLPS antigen/M84 Mab), which was found highly suitable to differentiate vaccinated from brucella-infected cattle. The use of C-ELISA II for monitoring bovine populations under an eradication programme is recommended. (author)

  13. Antiprothrombin Antibodies

    Directory of Open Access Journals (Sweden)

    Polona Žigon

    2015-05-01

    Full Text Available In patients with the antiphospholipid syndrome (APS, the presence of a group of pathogenic autoantibodies called antiphospholipid antibodies causes thrombosis and pregnancy complications. The most frequent antigenic target of antiphospholipid antibodies are phospholipid bound β2-glycoprotein 1 (β2GPI and prothrombin. The international classification criteria for APS connect the occurrence of thrombosis and/or obstetric complications together with the persistence of lupus anticoagulant, anti-cardiolipin antibodies (aCL and antibodies against β2GPI (anti-β2GPI into APS. Current trends for the diagnostic evaluation of APS patients propose determination of multiple antiphospholipid antibodies, among them also anti-prothrombin antibodies, to gain a common score which estimates the risk for thrombosis in APS patients. Antiprothrombin antibodies are common in APS patients and are sometimes the only antiphospholipid antibodies being elevated. Methods for their determination differ and have not yet been standardized. Many novel studies confirmed method using phosphatidylserine/prothrombin (aPS/PT ELISA as an antigen on solid phase encompass higher diagnostic accuracy compared to method using prothrombin alone (aPT ELISA. Our research group developed an in-house aPS/PT ELISA with increased analytical sensitivity which enables the determination of all clinically relevant antiprothrombin antibodies. aPS/PT exhibited the highest percentage of lupus anticoagulant activity compared to aCL and anti-β2GPI. aPS/PT antibodies measured with the in-house method associated with venous thrombosis and presented the strongest independent risk factor for the presence of obstetric complications among all tested antiphospholipid antibodies

  14. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples

    Science.gov (United States)

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-01-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469

  15. Effect of haemolysis and repeated freeze-thawing cycles on wild boar serum antibody testing by ELISA

    Directory of Open Access Journals (Sweden)

    Boadella Mariana

    2011-11-01

    Full Text Available Abstract Background Monitoring wildlife diseases is needed to identify changes in disease occurrence. Wildlife blood samples are valuable for this purpose but are often gathered haemolysed. To maximise information, sera often go through repeated analysis and freeze-thaw cycles. Herein, we used samples of clean and haemolysed Eurasian wild boar (Sus scrofa serum stored at -20°C and thawed up to five times to study the effects of both treatments on the outcome of a commercial ELISA test for the detection of antibodies against Suid Herpesvirus 1 (ADV. Results The estimated prevalence of antibodies against ADV was 50-53% for clean and haemolysed sera. Hence, haemolysis did not reduce the mean observed serum antibody prevalence. However, 10 samples changed their classification after repeated freeze-thawing. This included 3 (15% of the clean sera and 7 (41% of the haemolysed sera. Conclusions We recommend (1 establishing more restrictive cut-off values when testing wildlife sera, (2 recording serum quality prior to sample banking, (3 recording the number of freezing-thawing cycles and (4 store sera in various aliquots to reduce repeated usage. For instance, sera with more than 3 freeze-thaw cycles and a haemolysis of over 3 on a scale of 4 should better be discarded for serum antibody monitoring. Even clean (almost not haemolysed sera should not go through more than 5 freeze-thaw cycles.

  16. Surveillance of bluetongue virus antibody in goats using a recombinant VP7-based indirect ELISA in the coastal saline area of West Bengal, India

    Directory of Open Access Journals (Sweden)

    Raj K. Singh

    2009-06-01

    Full Text Available The authors describe the serological surveillance of bluetongue virus (BTV group-specific antibody in goats of the coastal saline (Sunderban area of West Bengal, India. A recombinant viral protein 7 (rVP7-based indirect enzyme-linked immunosorbent assay (ELISA was used to detect the antibody in sera. The bacterially expressed rVP7 was purified by affinity chromatography. The diagnostic performance of the assay was assessed by comparing it to the commercially available previously validated competitive ELISA. Using the control and 1 202 test sera, the cut-off value, sensitivity and specificity as well as other performance characteristics e.g. the Youden index, efficiency, positive and negative predictive value and prevalence were estimated. Field-collected goat sera (n = 1 202 were tested and a serological prevalence rate of 47% was observed in the study area.

  17. Development of a multiplex lateral flow strip test for foot-and-mouth disease virus detection using monoclonal antibodies.

    Science.gov (United States)

    Yang, Ming; Caterer, Nigel R; Xu, Wanhong; Goolia, Melissa

    2015-09-01

    Foot-and-mouth disease (FMD) is one of the world's most highly contagious animal diseases with tremendous economic consequences. A rapid and specific test for FMD diagnosis at the site of a suspected outbreak is crucial for the implementation of control measures. This project developed a multiplex lateral flow immunochromatographic strip test (multiplex-LFI) for the rapid detection and serotyping of FMD viruses. The monoclonal antibodies (mAbs) against serotypes O, A, and Asia 1 were used as capture mAbs. The mAbs were conjugated with fluorescein, rhodamine or biotin for serotype O, A and Asia 1, respectively. The detection mAbs which consisted of a serotype-independent mAb in combination with one serotype A-specific mAb and one Asia 1-specific mAb, were each colloidal gold-conjugated. The strips used in this study contained one control line and three test lines, which corresponded to one of the three serotypes, O, A or Asia 1. The newly developed multiplex-LFI strip test specifically identified serotype O (n=46), A (n=45) and Asia 1 (n=17) in all tested field isolates. The sensitivity of this strip test was comparable to the double antibody sandwich ELISA for serotypes O and A, but lower than the ELISA for serotype Asia 1. The multiplex-LFI strip test identified all tissue suspensions from animals that were experimentally inoculated with serotypes O, A or Asia 1. FMD viruses were detected in 38% and 50% of the swab samples from the lesion areas of experimentally inoculated sheep for serotypes O and A, respectively. The capability of the multiplex-LFI strip tests to produce rapid results with high specificity for FMD viruses of multiple serotypes makes this test a valuable tool to detect FMD viruses at outbreak sites. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  18. Quality control using a multilevel logistic model for the Danish pig Salmonella surveillance antibody-ELISA programme

    DEFF Research Database (Denmark)

    Bak, Hanne; Ekeroth, Lars; Houe, Hans

    2007-01-01

    In Denmark, the level of Salmonella infection in pig herds is monitored with a surveillance programme using an indirect antibody ELISA. Our purpose with the present study was to determine whether sample results from the programme were useful in the quality control of this ELISA. Test results from...... throughout. Analysis of the test results from the wells with test samples gave good information on systematic errors across the microtitre plates, and severe errors appeared significant even when data from short time periods were used....... the year 2003, in which the laboratory experienced a technical problem with an automatic microtitre-plate washing machine, were examined statistically. We chose 3 months for the analysis: January, where the problem was moderate, June with the problem more serious, and November, where the problem had been...... solved. A logistic analysis was carried out with outcome 0 for a negative test result and I for a positive test result. Row and column on the microtitre plates, multiprobe robot, and their interactions were included as fixed effects, and date, plate, and slaughterhouse were included as random effects...

  19. Validation of FAO/IAEA/PANAFTOSA ELISA kit for the detection of antibodies against foot-and-mouth disease virus in Venezuela

    International Nuclear Information System (INIS)

    Novell, M.; Ramos, P.; Ochoa, C.J.; Rodriguez, J.; Obregon, J.M.; Ruiz, R.

    1998-01-01

    A liquid phase blocking ELISA (LPBE) supplied by FAO/IAEA/PANAFTOSA has been evaluated for the qualitative and quantitative detection of specific antibodies to 'O' and 'A' serotypes of foot-and-mouth disease (FMD). A total of 240 bovine sera were analyzed. 120 sera from non-infected and non-vaccinated cattle were tested in a screening test showing a specificity of 99,2%. 120 from vaccinated cattle were tested in a titration assay giving a sensitivity of 99,2%. For serotype 'O' the titration test showed a protection of 80% and for serotype 'A' 75,6%. Antibody titers fluctuated between >112 and >1250 which indicates protection. (author)

  20. Analysis of the function of IL-10 in chickens using specific neutralising antibodies and a sensitive capture ELISA.

    Science.gov (United States)

    Wu, Zhiguang; Hu, Tuanjun; Rothwell, Lisa; Vervelde, Lonneke; Kaiser, Pete; Boulton, Kay; Nolan, Matthew J; Tomley, Fiona M; Blake, Damer P; Hume, David A

    2016-10-01

    In mammals, the inducible cytokine interleukin 10 is a feedback negative regulator of inflammation. To determine the extent to which this function is conserved in birds, recombinant chicken IL-10 was expressed as a secreted human Ig Fc fusion protein (chIL-10-Fc) and used to immunise mice. Five monoclonal antibodies (mAb) which specifically recognise chicken IL-10 were generated and characterised. Two capture ELISA assays were developed which detected native chIL-10 secreted from chicken bone marrow-derived macrophages (chBMMs) stimulated with lipopolysaccharide (LPS). Three of the mAbs detected intracellular IL-10. This was detected in only a subset of the same LPS-stimulated chBMMs. The ELISA assay also detected massive increases in circulating IL-10 in chickens challenged with the coccidial parasite, Eimeria tenella. The same mAbs neutralised the bioactivity of recombinant chIL-10. The role of IL-10 in feedback control was tested in vitro. The neutralising antibodies prevented IL-10-induced inhibition of IFN-γ synthesis by mitogen-activated lymphocytes and increased nitric oxide production in LPS-stimulated chBMMs. The results confirm that IL-10 is an inducible feedback regulator of immune response in chickens, and could be the target for improved vaccine efficacy or breeding strategies. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. A comparative evaluation of avidin-biotin ELISA and micro SNT for detection of antibodies to infectious bovine rhinotracheitis in cattle population of Odisha, India

    Directory of Open Access Journals (Sweden)

    Priyaranjan Das

    2014-08-01

    Full Text Available Aim: The present study was undertaken to serologically detect Infectious Bovine Rhinotracheitis (IBR in the cattle population of Odisha, India using micro-Serum neutralization test (micro SNT and Avidin-Biotin Enzyme linked immuno sorbent assay (AB ELISA and finding out their comparative efficacy to serve as a suitable diagnostic tool in field condition. Materials and Methods: The study was carried out using serum samples (n=180 collected randomly from cattle populations of nine districts of Odisha. Similarly vaginal swabs (n=26 from cattle having history of repeat breeding, abortion, vulvo-vaginitis and nasal swabs (n=8 from calves with respiratory symptoms and nasal discharge were collected aseptically, to ascertain the circulation of virus among the cattle population. Results: Virus isolation by cell culture and subsequent confirmation by polymerase chain reaction confirmed four isolates. Screening of serum samples revealed 9.44% and 12.22% samples positive for IBR antibodies in micro SNT and AB ELISA respectively. The sensitivity and specificity of AB ELISA test was found to be 88.23% and 95.70% respectively taking micro SNT as gold standard and the kappa value between the two tests was 0.75. Conclusion: Screening of serum samples revealed 9.44% and 12.22% samples positive for IBR antibodies in micro SNT and AB ELISA respectively, thus highlighting the circulation of virus among the livestock population of Odisha and that AB ELISA could be more efficiently applied for the sero-diagnosis of IBR virus infections at field conditions, with demand for more study on faster, efficient and large scale screening of the infected animals.

  2. Analysis of fenbendazole residues in bovine milk by ELISA.

    Science.gov (United States)

    Brandon, David L; Bates, Anne H; Binder, Ronald G; Montague, William C; Whitehand, Linda C; Barker, Steven A

    2002-10-09

    Fenbendazole residues in bovine milk were analyzed by ELISAs using two monoclonal antibodies. One monoclonal antibody (MAb 587) bound the major benzimidazole anthelmintic drugs, including fenbendazole, oxfendazole, and fenbendazole sulfone. The other (MAb 591) was more specific for fenbendazole, with 13% cross-reactivity with the sulfone and no significant binding to the sulfoxide metabolite. The limit of detection of the ELISA method in the milk matrix was 7 ppb for MAb 587 and 3 ppb for MAb 591. Fenbendazole was administered in feed, drench, and paste form to three groups of dairy cattle. Milk was collected immediately before dosing and then every 12 h for 5 days. The ELISA indicated that residue levels varied widely among individual cows in each group. Fenbendazole levels peaked at approximately 12-24 h and declined rapidly thereafter. Metabolites were detected at much higher levels than the parent compound, peaked at approximately 24-36 h, and declined gradually. Residue levels were undetectable by 72 h. The ELISA data correlated well with the total residues determined by chromatographic analysis, but the use of the two separate ELISAs did not afford an advantage over ELISA with the single, broadly reactive MAb 587. The ELISA method could be used to flag high-residue samples in on-site monitoring of fenbendazole in milk and is a potential tool for studying drug pharmacokinetics.

  3. [Use of new immunoglobulin isotype-specific ELISA-systems to detect Salmonella infections in pigs].

    Science.gov (United States)

    Ehlers, Joachim; Alt, Michael; Trepnau, Daniela; Lehmann, Jörg

    2006-01-01

    In Germany, the program for controlling salmonella infections in pigs is based on tests detecting salmonella-lipopolysaccharide (LPS) induced antibodies in meat-juice or blood. These conventional tests which are based on the technology of enzyme-linked immunosorbent assay (ELISA) detect exclusively or mainly immunoglobulin(lg)G antibodies. Meanwhile, novel ELISA systems (WCE-ELISA, 3-Isotype-Screening-ELISA) have been developed, which additionally detect the antibody classes IgM and IgA.This fact enables the registration of fresh salmonella infections (starting with day 5 p.i.) and thus, the distinction between early and older infections. The results show that animals with early salmonella infections appear significantly more often in herds with a high than with a low prevalence. With the newly developed tests this group of animals can be detected much more efficiently and precisely than with the tests used so far. Due to their clearly improved sensitivity the application of the WCE-ELISA and the 3-Isotype-Screening-ELISA in terms of the QS-Salmonella-Monitoring program can therefore significantly improve the selection of farms with potential salmonella excretors. Additionally, the WCE-ELISA can be applied very suitable for the examination of individual animals.

  4. Immobilization and functional reconstitution of antibody Fab fragment by solid-phase refolding.

    Science.gov (United States)

    Kumada, Yoichi; Hamasaki, Kyoto; Nakagawa, Aya; Sasaki, Eiju; Shirai, Tatsunori; Okumura, Masahiro; Inoue, Manami; Kishimoto, Michimasa

    2013-12-31

    In this study, we demonstrated the successful preparation of a Fab antibody-immobilized hydrophilic polystyrene (phi-PS) plate via one- and two-step solid-phase refolding methods. Both polystyrene-binding peptide (PS-tag)-fused Fd fragment of heavy chain (Fab H-PS) and full-length of light-chain (Fab L-PS) were individually produced in insoluble fractions of Escherichia coli cells, and they were highly purified in the presence of 8M of urea. Antigen-binding activities of Fab antibody immobilized were correctly recovered by the one-step solid-phase refolding method that a mixture of Fab H-PS and Fab L-PS was immobilized in the presence of 0.5-2M urea, followed by surface washing of the phi-PS plate with PBST. These results indicate that by genetic fusion of a PS-tag, a complex between Fab H and Fab L was efficiently immobilized on the surface of a phi-PS plate even in the presence of a low concentration of urea, and was then correctly refolded to retain its high antigen-binding activity via removal of the urea. A two-step solid-phase refolding method whereby Fab H-PS and Fab L-PS were successively refolded on the surface of a phi-PS plate also resulted in Fab antibody formation on the plate. Furthermore, both the binding affinity and the specificity of the Fab antibody produced by the two-step method were highly maintained, according to the results of sandwich ELISA and competitive ELISA using Fab antibody-immobilized plate via two-step solid-phase refolding. Thus, the solid-phase refolding method demonstrated in this study should be quite useful for the preparation of a Fab antibody-immobilized PS surface with high efficiency from individually produced Fab H-PS and Fab L-PS. This method will be applicable to the preparation of a large Fab antibody library on the surface of a PS plate for use in antibody screening. © 2013. Published by Elsevier B.V. All rights reserved.

  5. A new ELISA for determination of potency in snake antivenoms.

    Science.gov (United States)

    Rial, A; Morais, V; Rossi, S; Massaldi, H

    2006-09-15

    A competitive ELISA for potency determination of bothropic equine antivenom was developed and compared to the conventional in vivo ED(50) assay, with the aim of partially substituting the in vivo assay in the monitoring of antivenom immunoglobulin levels. On this purpose, blood samples were taken at different times during and after the immunization protocol of the lot of horses used for production of snake antivenom at the Instituto de Higiene, Uruguay. Both the competitive ELISA and the ED(50) assay were performed on those samples. In addition, a group of five commercial pepsin-digested antivenoms were tested by both methods. A significant (P<0.001) correlation (Pearson's r=0.957) was found between the ELISA titres and the corresponding ED(50) values, indicating that the in vitro test can estimate the neutralizing antibody capacity of the sera as well as the in vivo assay. By means of this new ELISA, it was found that the immunized animals maintained good venom antibody titres, in the order of 20-50% of the maximum achieved, even 10 month after the end of the immunization schedule. The main advantage of our ELISA design is its ability to correctly estimate the neutralization capacity of crude hyperimmune plasma and antivenom sera independently of their antibody composition in terms of whole IgG or F(ab')(2) fragment.

  6. The Platelia Aspergillus ELISA in diagnosis of invasive pulmonary aspergilosis (IPA).

    Science.gov (United States)

    Siemann, M; Koch-Dörfler, M

    2001-01-01

    The sensitivity of a sandwich enzyme-linked immunosorbent assay (ELISA) for detecting Aspergillus galactomannan was evaluated with 66 serum samples and 113 specimens of the respiratory tract obtained from 52 patients with pulmonary diseases. The patients were divided into five groups: proven invasive pulmonary aspergillosis (IPA) (five patients), probable IPA (seven patients), Aspergillus colonization (eight patients) or unlikely Aspergillus infection (27 patients). Another five patients with doubtful diagnostic test results are discussed in detail. The results of the Platelia Aspergillus ELISA (Sanofi Pasteur, Freiburg, Germany) in testing specimens of the respiratory tract were 90% sensitivity in proven (serum 38%), 60% in probable (serum 37%) and 71% in Aspergillus colonization (serum 0%). Furthermore, 85% of the Aspergillus spp. from positive cultures of specimens of the respiratory tract were also detected in the ELISA. A total of 57% of the culture negative specimens of patients with a least one positive culture or proven aspergillosis in a series of specimens were positive in the ELISA.

  7. General approach to standardization of the solid-phase radioimmunoassay for quantitation of class-specific antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Zollinger, W D; Boslego, J W [Walter Reed Army Inst. of Research, Washington, DC (USA)

    1981-10-30

    The feasibility of using an anti-human immunoglobulin/human immunoglobulin/(/sup 125/I)anti-human immunoglobulin 'sandwich' in a solid-phase radioimmunoassay to produce a standard curve which could be used to quantitate antigen-specific antibody of a particular immunoglobulin class was investigated. The amount of secondary antibody (SAb) bound was determined as a function of whether the primary antibody (PAb) was bound to its specific solid-phase antigen or by a solid-phase anti-human immunoglobulin. No significant difference between the two values was observed. Quantitation of anti-tetanus toxoid antibody by this method was in a good agreement with quantitative precipitin tests. Comparison of SAb binding as a function of the way the PAb is bound was extended to class-specific PAb by use of murine monoclonal antibodies to meningococcal antigens. In most cases somewhat greater binding of SAb occurred when PAb was bound to antigen, but in several cases where low avidity antibody and/or poor quality antigens were used, greater SAb binding occurred when PAb was bound by anti-mouse immunoglobulin. The results indicate that this approach may be useful as a general method for standardizing the SPRIA and other solid-phase immunoassays such as the ELISA to measure class-specific antibody.

  8. Novel indirect enzyme-linked immunosorbent assay (ELISA) method to detect Total E. coli in water environment

    International Nuclear Information System (INIS)

    Wang Na; He Miao; Shi Hanchang

    2007-01-01

    In order to establish ELISA (enzyme-linked immunosorbent assay) method to detect Total E. coli in water environment, E. coli multi-characters antigens in water environment were prepared according to the characters of kinds of E. coli serotypes, including antigen of whole cell, antigen of disrupted whole cell, somatic antigen, flagellar antigen and fimbrial antigen. Total E. coli polyclonal antibodies were obtained from the New Zealand rabbits immunized with these five antigens, respectively. Antibodies generated in this research are with high titers and good purity, can conjugate with antigens, specifically, stably and strongly. Indirect ELISA shows the titers of antibody of whole cell and antibody of disrupted whole cell are both over 1 x 10 5 . The cross-reactivity of the antibody is from 12 to 30% which indicate the specificity of the antibody against Total E. coli. Based on these antibodies, we established indirect ELISA method to detect Total E. coli in water environment. The matrix effects were studied and the results show that there is no significant influence by all the factors. The ELISA result shows that the detection limitation could be 10 4 CFU (colony forming units) L -1 . The indirect ELISA method developed in this study is well suited for Total E. coli analysis in real water samples as a rapid screen method

  9. Uniform Orientation of Biotinylated Nanobody as an Affinity Binder for Detection of Bacillus thuringiensis (Bt) Cry1Ac Toxin

    Science.gov (United States)

    Li, Min; Zhu, Min; Zhang, Cunzheng; Liu, Xianjin; Wan, Yakun

    2014-01-01

    Nanobodies are the smallest natural fragments with useful properties such as high affinity, distinct paratope and high stability, which make them an ideal tool for detecting target antigens. In this study, we generated and characterized nanobodies against the Cry1Ac toxin and applied them in a biotin-streptavidin based double antibodies (nanobodies) sandwich-ELISA (DAS-ELISA) assay. After immunizing a camel with soluble Cry1Ac toxin, a phage displayed library was constructed to generate Nbs against the Cry1Ac toxin. Through successive rounds of affinity bio-panning, four nanobodies with greatest diversity in CDR3 sequences were obtained. After affinity determination and conjugating to HRP, two nanobodies with high affinity which can recognize different epitopes of the same antigen (Cry1Ac) were selected as capture antibody (Nb61) and detection antibody (Nb44). The capture antibody (Nb61) was biotinylated in vivo for directional immobilization on wells coated with streptavidin matrix. Both results of specificity analysis and thermal stability determination add support for reliability of the following DAS-ELISA with a minimum detection limit of 0.005 μg·mL−1 and a working range 0.010–1.0 μg·mL−1. The linear curve displayed an acceptable correlation coefficient of 0.9976. These results indicated promising applications of nanobodies for detection of Cry1Ac toxin with biotin-streptavidin based DAS-ELISA system. PMID:25474492

  10. Uniform Orientation of Biotinylated Nanobody as an Affinity Binder for Detection of Bacillus thuringiensis (Bt Cry1Ac Toxin

    Directory of Open Access Journals (Sweden)

    Min Li

    2014-12-01

    Full Text Available Nanobodies are the smallest natural fragments with useful properties such as high affinity, distinct paratope and high stability, which make them an ideal tool for detecting target antigens. In this study, we generated and characterized nanobodies against the Cry1Ac toxin and applied them in a biotin-streptavidin based double antibodies (nanobodies sandwich-ELISA (DAS-ELISA assay. After immunizing a camel with soluble Cry1Ac toxin, a phage displayed library was constructed to generate Nbs against the Cry1Ac toxin. Through successive rounds of affinity bio-panning, four nanobodies with greatest diversity in CDR3 sequences were obtained. After affinity determination and conjugating to HRP, two nanobodies with high affinity which can recognize different epitopes of the same antigen (Cry1Ac were selected as capture antibody (Nb61 and detection antibody (Nb44. The capture antibody (Nb61 was biotinylated in vivo for directional immobilization on wells coated with streptavidin matrix. Both results of specificity analysis and thermal stability determination add support for reliability of the following DAS-ELISA with a minimum detection limit of 0.005 μg·mL−1 and a working range 0.010–1.0 μg·mL−1. The linear curve displayed an acceptable correlation coefficient of 0.9976. These results indicated promising applications of nanobodies for detection of Cry1Ac toxin with biotin-streptavidin based DAS-ELISA system.

  11. An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1)

    Science.gov (United States)

    Selman, L.; Henriksen, M.L.; Brandt, J.; Palarasah, Y.; Waters, A.; Beales, P.L.; Holmskov, U.; Jørgensen, T.J.D.; Nielsen, C.; Skjodt, K.; Hansen, S.

    2012-01-01

    Collectin 11 (CL-11), also referred to as collectin kidney 1 (CL-K1), is a pattern recognition molecule that belongs to the collectin group of proteins involved in innate immunity. It interacts with glycoconjugates on pathogen surfaces and has been found in complex with mannose-binding lectin-associated serine protease 1 (MASP-1) and/or MASP-3 in circulation. Mutation in the CL-11 gene was recently associated with the developmental syndrome 3MC. In the present study, we established and thoroughly validated a sandwich enzyme-linked immunosorbent assay (ELISA) based on two different monoclonal antibodies. The assay is highly sensitive, specific and shows excellent quantitative characteristics such as reproducibility, dilution linearity and recovery (97.7–104%). The working range is 0.15–34 ng/ml. The CL-11 concentration in two CL-11-deficient individuals affected by the 3MC syndrome was determined to be below 2.1 ng/ml. We measured the mean serum CL-11 concentration to 284 ng/ml in 100 Danish blood donors, with a 95% confidence interval of 269–299 ng/ml. There was no significant difference in the CL-11 concentration measured in matched serum and plasma samples. Storage of samples and repeated freezing and thawing to a certain extent did not influence the ELISA. This ELISA offers a convenient and reliable method for studying CL-11 levels in relation to a variety of human diseases and syndromes. PMID:22301270

  12. A comparison of sperm agglutination and immobilization assays with a quantitative ELISA for anti-sperm antibody in serum.

    Science.gov (United States)

    Lynch, D M; Leali, B A; Howe, S E

    1986-08-01

    An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.

  13. Validation of an ELISA for the concurrent detection of total antibodies (IgM and IgG to Rift Valley fever virus

    Directory of Open Access Journals (Sweden)

    Charlotte E. Ellis

    2014-05-01

    Full Text Available Rift Valley fever virus (RVFV infects humans and livestock, causing haemorrhaging andabortions in animals. Three major RVF epizootics have occurred in South Africa since the1950s and the outbreak in 2010 had a mortality rate of 10.7% in humans. Accurate and earlydetection is therefore essential for management of this zoonotic disease. Enzyme-linkedimmunosorbent assays (ELISAs have been developed for the detection of either IgM or IgGantibodies to RVFV in animal sera. In this study, data are presented on the validation of adouble-antigen ELISA for the simultaneous detection of both classes of antibodies to RVFV ina single test. ELISA plates were coated with a recombinant nucleoprotein. The nucleoprotein,conjugated to horseradish peroxidase, was used as the detecting reagent. A total of 534 serafrom sheep and cattle were used in the validation. The sheep sera were collected during a RVFpathogenesis study at the Agricultural Research Council (ARC – Onderstepoort VeterinaryInstitute and the cattle sera were collected during an outbreak of RVF in 2008 at the ARC –Animal Production Institute in Irene, Pretoria. The ELISA had a diagnostic sensitivity of 98.4%and a specificity of 100% when compared to a commercial cELISA. This convenient and fastassay is suitable for use in serological surveys or monitoring immune responses in vaccinatedanimals.

  14. Improved Soluble ScFv ELISA Screening Approach for Antibody Discovery Using Phage Display Technology.

    Science.gov (United States)

    Tohidkia, Mohammad R; Sepehri, Maryam; Khajeh, Shirin; Barar, Jaleh; Omidi, Yadollah

    2017-09-01

    Phage display technology (PDT) is a powerful tool for the isolation of recombinant antibody (Ab) fragments. Using PDT, target molecule-specific phage-Ab clones are enriched through the "biopanning" process. The individual specific binders are screened by the monoclonal scFv enzyme-linked immunosorbent assay (ELISA) that may associate with inevitable false-negative results. Thus, in this study, three strategies were investigated for optimization of the scFvs screening using Tomlinson I and J libraries, including (1) optimizing the expression of functional scFvs, (2) improving the sensitivity of ELISA, and (3) preparing different samples containing scFvs. The expression of all scFv Abs was significantly enhanced when scFv clones were cultivated in the terrific broth (TB) medium at the optimum temperature of 30 °C. The protein A-conjugated with horseradish peroxidase (HRP) was found to be a well-suited reagent for the detection of Ag-bound scFvs in comparison with either anti-c-myc Ab or the mixing procedure. Based on our findings, it seems there is no universal media supplement for an improved expression of all scFvs derived from both Tomlinson I and J libraries. We thus propose that expression of scFv fragments in a microplate scale is largely dependent on a variety of parameters, in particular the scFv clones and relevant sequences.

  15. A polyclonal antibody based immunoassay detects seven subtypes of Shiga toxin 2 produced by Escherichia coli in human and environmental samples.

    Directory of Open Access Journals (Sweden)

    Xiaohua He

    Full Text Available BACKGROUND: Shiga toxin-producing Escherichia coli (STEC are frequent causes of severe human diseases ranging from diarrhea to hemolytic uremic syndrome. The existing strategy for detection of STEC relies on the unique sorbitol-negative fermentation property of the O157 strains, the most commonly identified serotype has been E. coli O157. It is becoming increasingly evident, however, that numerous non-O157 STEC serotypes also cause outbreaks and severe illnesses. It is necessary to have new methods that are capable of detecting all STEC strains. METHODS AND FINDINGS: Here we describe the development of a sandwich ELISA assay for detecting both O157 and non-O157 STECs by incorporating a novel polyclonal antibody (pAb against Stx2. The newly established immunoassay was capable of detecting Stx2a spiked in environmental samples with a limit of detection between 10 and 100 pg/mL in soil and between 100 and 500 pg/mL in feces. When applied to 36 bacterial strains isolated from human and environmental samples, this assay detected Stx2 in all strains that were confirmed to be stx2-positive by real-time PCR, demonstrating a 100% sensitivity and specificity. CONCLUSIONS: The sandwich ELISA developed in this study will enable any competent laboratory to identify and characterize Stx2-producing O157 and non-O157 strains in human and environmental samples, resulting in rapid diagnosis and patient care. The results of epitope mapping from this study will be useful for further development of a peptide-based antibody and vaccine.

  16. Enzyme immunoassay for measurement of murine plasminogen activator inhibitor-1, employing a specific antibody produced by the DNA vaccine method.

    Science.gov (United States)

    Yamada, Takayuki; Takagi, Akira; Takeshita, Kyosuke; Yamamoto, Koji; Ito, Masafumi; Matsushita, Tadashi; Murate, Takashi; Saito, Hidehiko; Kojima, Tetsuhito

    2003-01-01

    We developed a sensitive immunoassay to determine the concentration of mouse plasminogen activator inhibitor-1. The assay was a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) based on the production of a specific polyclonal antibody against mouse plasminogen activator inhibitor type-1 (PAI-1) used both as a trapping and detecting antibody. This antibody was raised in a rabbit by direct introduction of the expression vector plasmid DNA encoding mouse PAI-1, instead of conventional immunization with the purified protein. The standard curve was constructed with a recombinant glutathione S-transferase (GST)-mouse PAI-1 fusion protein (GST-mPAI-1) and dose-response of the assay was linear for GST-mPAI-1 between 6.25 and 100 pM. In order to assess the consistency of the assay, we measured PAI-1 antigen in normal mouse pooled plasma several times. We found that the intra-assay and inter-assay coefficients of variation (CV) were 4.8% and 9.2%, respectively, indicating that the ELISA would be sufficiently repeatable and reproducible. In this assay, lipopolysaccharide (LPS)-injected mice showed substantially higher levels (22-fold) of plasma PAI-1 antigen than did control mice (12.5+/-2.4 vs. 0.58+/-0.16 nM), similar to results reported elsewhere. Taken together, the DNA vaccine method is extremely useful for preparing specific antibodies against mouse PAI-1, which can be utilized to establish the ELISA and analyze the profile of PAI-1 distributions in mice under various conditions. This approach might also be useful for immunological investigation of other coagulation factors and related proteins.

  17. Tailoring Sandwich Face/Core Interfaces for Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A face/core debond in a sandwich structure may propagate in the interface or kink into either the face or core. It is found that certain modifications of the face/core interface region influence the kinking behavior, which is studied experimentally in the present paper. A sandwich double cantilever....... The transition points where the crack kinks are identified and the influence of four various interface design modifications on the propagation path and fracture resistance are investigated....

  18. Ultrasensitive and accelerated detection of ciguatoxin by capillary electrophoresis via on-line sandwich immunoassay with rotating magnetic field and nanoparticles signal enhancement.

    Science.gov (United States)

    Zhang, Zhaoxiang; Zhang, Chaoying; Luan, Wenxiu; Li, Xiufeng; Liu, Ying; Luo, Xiliang

    2015-08-12

    A sensitive and rapid on-line immunoassay for the determination of ciguatoxin CTX3C was developed based on a capillary mixing system, which was integrated with capillary electrophoresis (CE) separation and electrochemical (EC) detection. In the sandwich immunoassay system, anti-CTX3C-functionalized magnetic nanoparticles were used as immunosensing probes, and horseradish peroxidase (HRP) and anti-CTX3C antibody were bound onto the surface of gold nanoparticles (AuNPs) and used as recognition elements. Online formation of immunocomplex was realized in capillary inlet end with an external rotating magnetic field. Compared with classical HPLC-MS and ELISA, the assay adopting AuNPs as multienzyme carriers and online sandwich immunoassay format with rotating magnetic field exhibited higher sensitivity and shorter assay time. The linear range of the assay for CTX3C was from 0.6 to 150 ng/L with a correlation coefficient of 0.9948 (n = 2), and the detection limit (S/N = 3) was 0.09 ng/L. The developed assay showed satisfying reproducibility and stability, and it was successfully applied for the quantification of CTX3C in fish samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Performance of the multitarget Mikrogen Chlamydia trachomatis IgG ELISA in the prediction of tubal factor infertility (TFI) in subfertile women : Comparison with the Medac MOMP IgG ELISA plus

    NARCIS (Netherlands)

    van Ess, Eleanne F.; Ouburg, Sander; Spaargaren, Joke; Land, Jolande A.; Morre, Servaas A.

    2017-01-01

    There is a need for more accurate Chlamydia trachomatis (CT) IgG antibody tests for tubal factor infertility (TFI) diagnostics. We evaluated the predictive value for TFI of Medac ELISA plus (MOMP) and multitarget Mikrogen ELISA (MOMP-CPAF-TARP). Based on Medac ELISA plus results, 183 subfertile

  20. Standardization of micro-enzyme-linked immunosorbent assay (ELISA) and Western blot for detection of Trypanosoma cruzi antibodies using extracts from Mexican strains as antigens.

    Science.gov (United States)

    Sánchez, B; Monteón, V; Reyes, P A; Espinoza, B

    2001-01-01

    This report describes two assays for the detection of anti-Trypanosoma cruzi antibodies using Mexican strains of the parasite and the concordance with two assays previously evaluated at the Instituto Nacional de Cardiología Ignacio Chávez in Mexico City. Micro-enzyme-linked immunosorbent assay (ELISA) and Western blot were used for the detection of T. cruzi antibodies with a total extract of epimastigote from Ninoa and Queretaro, which are Mexican strains of T. cruzi. To standardize these methods, a total of 246 serum samples was used. In addition, sera from six confirmed Mexican chronic individuals in the asymptomatic phase were also used for comparison with the Argentinean antigen. ELISA was 100% specific in that no false positive results were found with sera of both healthy individuals and non-Chagasic cardiopaths. Sera from individuals infected with Leishmania sp. showed approximately 16% of cross-reaction with ELISA. The test showed a positive predictive value of 90% and a negative predictive value of 100%. Western blot was also a highly sensitive test for detecting chronic Chagasic symptomatic patients from Mexico because no false negative results were obtained. Furthermore, it was possible to use Western blot to detect seven immunodominant antigens of approximately 30, 32, 40, 42, 65, 70, and 83 kDa. Concordance with two previous standardized tests at the Instituto Nacional de Cardiología showed a Kappa index of 0.96, indicating high concordance between the results obtained at these two laboratories. Finally, ELISA using Ninoa antigen extract was more sensitive than ELISA with an Argentinean extract, which failed to detect individuals in the chronic asymptomatic phase (undetermined phase) of infection. This study indicates that ELISA and Western blot using Ninoa and/or Queretaro extracts of T. cruzi as antigens are useful tools in the detection of individuals who have been exposed to T. cruzi both in the undetermined/asymptomatic and symptomatic phases

  1. Development of a serodiagnostic IgM-ELISA for tick-borne encephalitis virus using subviral particles with strep-tag.

    Science.gov (United States)

    Nakayasu, Miki; Hirano, Minato; Muto, Memi; Kobayashi, Shintaro; Kariwa, Hiroaki; Yoshii, Kentaro

    2018-06-23

    Tick-borne encephalitis virus (TBEV) is a zoonotic agent causing severe encephalitis in humans. IgM antibody detection is useful for the serological diagnosis of TBEV infection, because IgM has high specificity for each flavivirus and indicates a recent infection. Commercial IgM-ELISA kits are somewhat expensive and difficulties in their sensitivity have been suggested due to their format and formalin-inactivated antigens. Therefore, the development of an inexpensive IgM-ELISA with high specificity and sensitivity is needed. In this study, a μ-capture ELISA was developed to detect TBEV-specific IgM antibodies using subviral particles (SPs) with strep-tag (strep-SP-IgM-ELISA). The results of our strep-SP-IgM-ELISA were highly correlated with diagnoses made by the neutralization test (sensitivity: 94.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in patients who could not be diagnosed with the neutralization test. Besides, 51 of 52 positive samples by a commercial IgM-ELISA were also diagnosed as positive by our strep-SP-IgM-ELISA (98.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in all samples that were inconclusive based on the commercial IgM-ELISA. Our strep-SP-IgM-ELISA will be useful for diagnoses in TBE-endemic areas. Copyright © 2018 Elsevier GmbH. All rights reserved.

  2. Biotin/avidin sandwich enzyme-linked immunosorbent assay for Culicidae mosquito blood meal identification

    Directory of Open Access Journals (Sweden)

    A. M. Marassá

    2008-01-01

    Full Text Available The knowledge of mosquitoes Culicidae host feeding patterns is basic to understand the roles of different species and to indicate their importance in the epidemiology of arthropod-borne diseases. A laboratory assay was developed aiming at standardizing the biotin-avidin sandwich enzyme-linked immunosorbent assay, which was unprecedented for mosquito blood meal identification. The enzyme-linked immunosorbent assay (ELISA activity was evaluated by the detection of titers on each sample of the 28 blood-fed Culex quinquefasciatus. In light of the high sensitivity that the technique permits, by means of small quantities of specific antibodies commercially provided and phosphatase substrate which reinforces additional dilutions, human and rat blood meals were readily identified in all laboratory-raised Culex quinquefasciatus tested. The assay was effective to detect human blood meal dilutions up to 1:4,096, which enables the technique to be applied in field studies. Additionally, the present results indicate a significant difference between the detection patterns recorded from human blood meal which corroborate the results of host feeding patterns.

  3. Monoclonal antibody to DNA containing thymine glycol

    Energy Technology Data Exchange (ETDEWEB)

    Leadon, S A; Hanawalt, P C [Stanford Univ., CA (USA). Dept. of Biological Sciences

    1983-08-01

    Exposure of DNA to ionizing or near ultraviolet radiation modifies thymine to form ring-saturated products. One of the major products formed is 5,6-dihydroxy-5.6-dihydrothymine (thymine glycol). Thymine glycol can also be selectively formed by oxidizing DNA with OsO/sub 4/. We have isolated hybrids that produce monoclonal antibodies against thymine glycol by fusing mouse myeloma cells (P3X63-Ag8-6.5.3) with spleen cells from BALB/c mice immunized with OsO/sub 4/-oxidized poly(dT) complexed with methylated bovine serum albumin. This report describes the characterization of the antibody from one hybridoma using a competitive enzyme-linked immunosorbent assay (ELISA). The antibody reacted with both single- and double-stranded DNA treated with OsO/sub 4/, and with OsO/sub 4/-treated poly(dA-dT) and poly(dT); it did not crossreact with unmodified or apurinic DNA. It also reacted with DNA treated with H/sub 2/O/sub 2/ or with ..gamma..-rays at doses as low as 250 rad. We were able to detect 2 fmoles of thymine glycol in OsO/sub 4/-treated DNA and could quantitate 1 thymine glycol per 220000 thymines. Using the antibody and the ELISA, the formation and removal of thymine glycol was examined in cultures of African green monkey cells irradiated with 25 krad of ..gamma..-rays. The antibody reactive sites produced by irradiation (8.5 per 10/sup 6/ thymines) were efficiently removed from the cellular DNA.

  4. Galactic binaries with eLISA

    OpenAIRE

    Nelemans, G.

    2013-01-01

    I review what eLISA will see from Galactic binaries -- double stars with orbital periods less than a few hours and white dwarf (or neutron star/black hole) components. I discuss the currently known binaries that are guaranteed (or verification) sources and explain why the expected total number of eLISA Galactic binaries is several thousand, even though there are large uncertainties in our knowledge of this population, in particular that of the interacting AM CVn systems. I very briefly sketch...

  5. Application of four anti-human interferon-alpha monoclonal antibodies for immunoassay and comparative analysis of natural interferon-alpha mixtures

    International Nuclear Information System (INIS)

    Andersson, G.; Lundgren, E.; Ekre, H.P.

    1991-01-01

    Four different mouse monoclonal antibodies to human interferon-alpha (IFN-alpha) were evaluated for application in quantitative and comparative analysis of natural IFN-alpha mixtures. Binding to IFN-alpha subtypes in solution revealed individual reactivity patterns. These patterns changed if the IFN-alpha molecules were immobilized either passively to a surface or bound by another antibody. Also, substitution of a single amino acid in IFN-alpha 2 affected the binding, apparently by altering the conformation. Isoelectric focusing of three natural IFN-alpha preparations from different sources, followed by immunoblotting, resulted in individual patterns with each of the four mAbs and also demonstrated variation in the composition of the IFN-alpha preparations. None of the mAbs was subtype specific, but by combining the different mAbs, and also applying polyclonal anti-human IFN-alpha antibodies, it was possible to design sensitive sandwich ELISAs with broad or more limited IFN-alpha subtype specificity

  6. Antibody profiling using a recombinant protein-based multiplex ELISA array accelerates recombinant vaccine development: Case study on red sea bream iridovirus as a reverse vaccinology model.

    Science.gov (United States)

    Matsuyama, Tomomasa; Sano, Natsumi; Takano, Tomokazu; Sakai, Takamitsu; Yasuike, Motoshige; Fujiwara, Atushi; Kawato, Yasuhiko; Kurita, Jun; Yoshida, Kazunori; Shimada, Yukinori; Nakayasu, Chihaya

    2018-05-03

    Predicting antigens that would be protective is crucial for the development of recombinant vaccine using genome based vaccine development, also known as reverse vaccinology. High-throughput antigen screening is effective for identifying vaccine target genes, particularly for pathogens for which minimal antigenicity data exist. Using red sea bream iridovirus (RSIV) as a research model, we developed enzyme-linked immune sorbent assay (ELISA) based RSIV-derived 72 recombinant antigen array to profile antiviral antibody responses in convalescent Japanese amberjack (Seriola quinqueradiata). Two and three genes for which the products were unrecognized and recognized, respectively, by antibodies in convalescent serum were selected for recombinant vaccine preparation, and the protective effect was examined in infection tests using Japanese amberjack and greater amberjack (S. dumerili). No protection was provided by vaccines prepared from gene products unrecognized by convalescent serum antibodies. By contrast, two vaccines prepared from gene products recognized by serum antibodies induced protective immunity in both fish species. These results indicate that ELISA array screening is effective for identifying antigens that induce protective immune responses. As this method does not require culturing of pathogens, it is also suitable for identifying protective antigens to un-culturable etiologic agents. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Differentiation of foot-and-mouth disease virus infected animals from vaccinated animals using a blocking ELISA based on baculovirus expressed FMDV 3ABC antigen and a 3ABC monoclonal antibody

    DEFF Research Database (Denmark)

    Sørensen, K.J.; de Stricker, K.; Dyrting, K.C.

    2005-01-01

    A blocking ELISA that differentiated foot-and-mouth disease virus (FMDV) infected animals from vaccinated animals was developed which uses baculovirus expressed FMDV 3ABC non-structural protein as antigen and monoclonal antibody against FMDV 3ABC non-structural protein as capture and detector...... infected with all seven serotypes of FMDV. The test detected antibodies from days 7 or 9 following experimental infection of non-vaccinated cattle and sheep, and in cattle strong positive reactions persisted for up to 395 days after infection. In vaccinated cattle that became carriers after challenge...... with homologous FMDV, positive reactions were obtained in all but one case. In some of these cattle the antibody response was detected late in comparison to the non-vaccinated infected cattle. The test gave results that compared favourably with two commercial ELISA's when used to test sera from cattle, pigs...

  8. A sensitive enzyme-linked immunosorbent assay for the determination of fish protein in processed foods.

    Science.gov (United States)

    Shibahara, Yusuke; Uesaka, Yoshihiko; Wang, Jun; Yamada, Shoichi; Shiomi, Kazuo

    2013-01-15

    Fish is one of the most common causes of food allergy and its major allergen is parvalbumin, a 12 kDa muscular protein. In this study, a sandwich enzyme-linked immunosorbent assay (ELISA) for the determination of fish protein in processed foods was developed using a polyclonal antibody raised against Pacific mackerel parvalbumin. The developed sandwich ELISA showed 22.6-99.0% reactivity (based on the reactivity to Pacific mackerel parvalbumin) to parvalbumins from various species of fish. The limits of detection and quantitation were estimated to be 0.23 and 0.70 μg protein per g of food, respectively. When the sandwich ELISA was subjected to inter-laboratory validation, spiked fish protein was recovered from five model processed foods in the range of 69.4-84.8% and the repeatability and reproducibility relative standard deviations were satisfactorily low (≤ 10.5%). Thus, the sandwich ELISA was judged to be a useful tool to determine fish protein in processed foods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Avidity of anti-malarial antibodies inversely related to transmission intensity at three sites in Uganda.

    Science.gov (United States)

    Ssewanyana, Isaac; Arinaitwe, Emmanuel; Nankabirwa, Joaniter I; Yeka, Adoke; Sullivan, Richard; Kamya, Moses R; Rosenthal, Philip J; Dorsey, Grant; Mayanja-Kizza, Harriet; Drakeley, Chris; Greenhouse, Bryan; Tetteh, Kevin K A

    2017-02-10

    People living in malaria endemic areas acquire protection from severe malaria quickly, but protection from clinical disease and control of parasitaemia is acquired only after many years of repeated infections. Antibodies play a central role in protection from clinical disease; however, protective antibodies are slow to develop. This study sought to investigate the influence of Plasmodium falciparum exposure on the acquisition of high-avidity antibodies to P. falciparum antigens, which may be associated with protection. Cross-sectional surveys were performed in children and adults at three sites in Uganda with varied P. falciparum transmission intensity (entomological inoculation rates; 3.8, 26.6, and 125 infectious bites per person per year). Sandwich ELISA was used to measure antibody responses to two P. falciparum merozoite surface antigens: merozoite surface protein 1-19 (MSP1-19) and apical membrane antigen 1 (AMA1). In individuals with detectable antibody levels, guanidine hydrochloride (GuHCl) was added to measure the relative avidity of antibody responses by ELISA. Within a site, there were no significant differences in median antibody levels between the three age groups. Between sites, median antibody levels were generally higher in the higher transmission sites, with differences more apparent for AMA-1 and in ≥5 year group. Similarly, median avidity index (proportion of high avidity antibodies) showed no significant increase with increasing age but was significantly lower at sites of higher transmission amongst participants ≥5 years of age. Using 5 M GuHCl, the median avidity indices in the ≥5 year group at the highest and lowest transmission sites were 19.9 and 26.8, respectively (p = 0.0002) for MSP1-19 and 12.2 and 17.2 (p = 0.0007) for AMA1. Avidity to two different P. falciparum antigens was lower in areas of high transmission intensity compared to areas with lower transmission. Appreciation of the mechanisms behind these findings as

  10. Development of a monoclonal-based enzyme-linked immunoassay for saxitoxin-induced protein.

    Science.gov (United States)

    Smith, D S; Kitts, D D

    1994-03-01

    A monoclonal antibody was generated against saxitoxin-induced protein (SIP) from the small shore crab Hemigrapsus oregenesis. SIP was induced by saxitoxin injection and could be detected in the crude crab extracts with both polyclonal and monoclonal antibody preparations. On Western blots, the polyclonal serum reacted against several bands which were induced by saxitoxin in the crude extracts. These bands represented proteins related to SIP. The monoclonal (4G5), however, was specific for the 79,000 mol. wt subunit of SIP. A triple antibody sandwich ELISA was developed in which polyclonal anti-SIP IgG was used as a trapping layer and monoclonal 4G5 was used as the detection layer. This assay was shown to be more specific and more accurate than a direct bind assay which employed the polyclonal antiserum alone. Although the polyclonal serum was more sensitive than the monoclonal on Western blots, the triple antibody sandwich and direct bind ELISAs were of comparable sensitivity.

  11. Seroprevalence of Toxoplasma gondii in southern districts of Tamil Nadu using IgG-ELISA.

    Science.gov (United States)

    Sucilathangam, G; Palaniappan, N; Sreekumar, C; Anna, T

    2012-10-01

    The present study was conducted to assess the seroprevalence of Toxoplasma gondii in and around Tirunelveli by in-house IgG assay using ELISA. Serum samples from 175 immunodeficient and 175 immunocompetent patients were collected at Tirunelveli district, Tamil Nadu from May 2006 to October 2007. They were subjected into in-house IgG assay using enzyme-linked immune sorbent assay (ELISA) in which tachyzoite soluble antigen derived from solubilised whole organisms was used. Out of 350 patients tested by IgG ELISA, 46 patients (13.14%) had antibodies for toxoplasmosis with mean OD value of 0.2 ± 0.073 and the OD value ranged from 0.144 to 0.444. Among the immunocompetent group of 175 patients, 19 patients (10.86%) had antibodies to toxoplasmosis whereas, in immunodeficient group of 175 patients, 27 patients (15.43%) had antibodies for toxoplasmosis. There was no statistical difference (P > 0.05) between the immunocompetent and immunodeficient group. The sensitivity and specificity of IgG ELISA in detecting toxoplasmosis was 90 and 100%, respectively. The overall seroprevalence of toxoplasmosis in and around Tirunelveli district of Tamil Nadu was 13.14% based on IgG ELISA. The study has proved ELISA to be a sensitive and specific procedure for the serodiagnosis of toxoplasmosis.

  12. Cross-reactivity among antigens of different air-borne fungi detected by ELISA using five monoclonal antibodies against Penicillium notatum.

    Science.gov (United States)

    Shen, H D; Lin, W L; Chen, R J; Han, S H

    1990-10-01

    Cross-reactivity among antigens of 12 genera of air-borne fungi, 13 species of Penicillium, and 5 species of Aspergillus was studied by ELISA using five monoclonal antibodies (MoAbs) against Penicillium notatum. Epitopes recognized by all the five MoAbs were susceptible to treatment of mild periodate oxidation and may therefore be associated with carbohydrates. Furthermore, our results showed that there is cross-reactivity among antigens of Penicillium, Aspergillus, and Eurotium species. By using these MoAbs, cross reactivity was not detected between antigens of Penicillium notatum and antigens of Fusarium solani, Alternaria porri, Cladosporium cladosporoides, Curvularia species, Nigrospora species, Aureobasidium pullulans, Wallemia species, Rhizopus arrhizus, and Candida albicans. Cross-reactivity among antigens of 11 species of Penicillium and 5 species of Aspergillus could be detected by ELISA using one of the five MoAbs (MoAb P15). The fact that there may be cross-reactivity among antigens of closely related fungi species should be considered in the diagnosis and treatment of mold allergic diseases.

  13. Double antibody solid-phase radioimmunoassay for staphylococcal enterotoxin A

    International Nuclear Information System (INIS)

    Lindroth, S.; Niskanen, A.

    1977-01-01

    A double antibody solid-phase (DASP) radioimmunoassay for staphylococcal enterotoxin A is described. In the assay the antigen-antibody complex is precipitated by anti-rabbit serum which is adsorbed onto a solid carrier (cellulose). The method is sensitive to 200 pg of enterotoxin. It was possible to detect a little as 2-5 ng of enterotoxin A/ml food extract from minced meat and sausage. Enterotoxins B and C were not found to inhibit the uptake of labled enterotoxin A at a level which might distort the results of the enterotoxin A assay. The DASP technique is sensitive, rapid, and easy to perform and thus compares favorably with other radioimmunoassays for enterotoxin. (orig.) [de

  14. Immobilization of antibodies and enzyme-labeled antibodies by radiation polymerization

    International Nuclear Information System (INIS)

    Kumakura, M.; Kaetsu, I.; Suzuki, M.; Adachi, S.

    1983-01-01

    Immobilization of antibodies and enzyme-labeled antibodies by radiation polymerization at low temperatures was studied. The antibody activity of antibody was not affected by irradiation at an irradiation dose of below 8 MR and low temperatures. Immobilization of peroxidase-labeled anti-rabbit IgG goat IgG, anti-peroxidase, peroxidase, and anti-alpha-fetoprotein was carried out with hydrophilic and hydrophobic monomers. The activity of the immobilized enzyme-labeled antibody membranes varied with the thickness of the membranes and increased with decreasing membrane thickness. The activity of the immobilized antibody particles was varied by particle size. Immobilized anti-alpha-fetoprotein particles and membranes can be used for the assay of alpha-fetoprotein by the antigen-antibody reaction, such as a solid-phase sandwich method with high sensitivity

  15. His-tag ELISA for the detection of humoral tumor-specific immunity

    Directory of Open Access Journals (Sweden)

    Disis Mary L

    2008-05-01

    Full Text Available Abstract Background The application of high throughput molecular techniques such as SEREX are resulting in the identification of a multitude of tumor associated antigens. As newly identified antigens are incorporated into a variety of clinical trials, standardization of immunologic monitoring methods becomes increasingly important. We questioned whether mammalian cell expression of a histadine-linked human protein could be used to produce antigen suitable for detecting tumor-specific humoral immunity and whether such an assay could be amenable to standardization for clinical use. Methods We designed a his-tagged capture ELISA based on lysate from genetically engineered CHO cells for detection of antibodies to insulin-like growth factor binding protein 2, a novel tumor antigen. We performed technical and preliminary clinical validation studies, including comparison to a standard indirect ELISA based on commercially prepared recombinant antigen. Results The his-tagged capture ELISA could be standardized. Precision experiments resulted in CVs 2 values of 0.99. In comparison to Western blot analysis, his-tag and indirect ELISA accurately identified 88% and 93% of samples, respectively. Sample concordance between capture and indirect assays was highly significant (p = 0.003. Furthermore, significantly greater levels of IGFBP-2 antibody immunity were found in cancer patients compared to normal controls (p = 0.008. Conclusion A genetically engineered cell lysate based ELISA can be amenable to standardization and can detect increased levels of antibody immunity to tumor-associated antigen in cancer patients compared to non tumor-bearing healthy controls.

  16. Lyme disease antibody

    Science.gov (United States)

    ... JavaScript. The Lyme disease blood test looks for antibodies in the blood to the bacteria that causes ... needed. A laboratory specialist looks for Lyme disease antibodies in the blood sample using the ELISA test . ...

  17. Analytically Sensitive Protein Detection in Microtiter Plates by Proximity Ligation with Rolling Circle Amplification.

    Science.gov (United States)

    Ebai, Tonge; Souza de Oliveira, Felipe Marques; Löf, Liza; Wik, Lotta; Schweiger, Caroline; Larsson, Anders; Keilholtz, Ulrich; Haybaeck, Johannes; Landegren, Ulf; Kamali-Moghaddam, Masood

    2017-09-01

    Detecting proteins at low concentrations in plasma is crucial for early diagnosis. Current techniques in clinical routine, such as sandwich ELISA, provide sensitive protein detection because of a dependence on target recognition by pairs of antibodies, but detection of still lower protein concentrations is often called for. Proximity ligation assay with rolling circle amplification (PLARCA) is a modified proximity ligation assay (PLA) for analytically specific and sensitive protein detection via binding of target proteins by 3 antibodies, and signal amplification via rolling circle amplification (RCA) in microtiter wells, easily adapted to instrumentation in use in hospitals. Proteins captured by immobilized antibodies were detected using a pair of oligonucleotide-conjugated antibodies. Upon target recognition these PLA probes guided oligonucleotide ligation, followed by amplification via RCA of circular DNA strands that formed in the reaction. The RCA products were detected by horseradish peroxidase-labeled oligonucleotides to generate colorimetric reaction products with readout in an absorbance microplate reader. We compared detection of interleukin (IL)-4, IL-6, IL-8, p53, and growth differentiation factor 15 (GDF-15) by PLARCA and conventional sandwich ELISA or immuno-RCA. PLARCA detected lower concentrations of proteins and exhibited a broader dynamic range compared to ELISA and iRCA using the same antibodies. IL-4 and IL-6 were detected in clinical samples at femtomolar concentrations, considerably lower than for ELISA. PLARCA offers detection of lower protein levels and increased dynamic ranges compared to ELISA. The PLARCA procedure may be adapted to routine instrumentation available in hospitals and research laboratories. © 2017 American Association for Clinical Chemistry.

  18. Influence of clinical and laboratory variables on faecal antigen ELISA results in dogs with canine parvovirus infection.

    Science.gov (United States)

    Proksch, A L; Unterer, S; Speck, S; Truyen, U; Hartmann, K

    2015-06-01

    False negative faecal canine parvovirus (CPV) antigen ELISA results in dogs with CPV infection are common, but the factors that lead to these false negative results are still unknown. The aim of this study was to investigate whether dogs with a false negative faecal CPV antigen ELISA result have milder clinical signs and laboratory changes, a lower faecal virus load, higher faecal and serum CPV antibody titres and a faster recovery than dogs with a positive result. Eighty dogs with CPV infection, confirmed by the presence of clinical signs and a positive faecal CPV polymerase chain reaction (PCR), were assigned to two groups according to their faecal antigen ELISA result. Time until presentation, severity of symptoms, laboratory parameters, faecal virus load, faecal and serum antibody titres, and CPV sequencing data were compared between both groups. In 38/80 dogs that were hospitalised until recovery, the time to recovery, mortality, and the course of the disease were compared between dogs with positive and negative faecal antigen ELISA results. Of the 80 dogs included, 41 (51.3%) had a false negative faecal antigen ELISA result. ELISA-negative dogs had a significantly shorter time until presentation, lower frequency of defaecation, lower faecal virus load, and higher serum antibody concentrations than ELISA-positive dogs. Laboratory changes, CPV shedding, and outcomes were not associated with faecal antigen ELISA results. In conclusion, low faecal CPV load and antibodies binding to CPV antigen in faeces are likely to be important reasons for false negative faecal antigen ELISA results. Dogs with clinical signs of CPV infection should be retested by faecal PCR. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Mimotopes selected by biopanning with high-titer HIV-neutralizing antibodies in plasma from Chinese slow progressors

    Directory of Open Access Journals (Sweden)

    Xiaoli Zhang

    Full Text Available OBJECTIVE: One approach to identifying HIV-1 vaccine candidates is to dissect the natural antiviral immune response in treatment-naïve individuals infected for over ten years, considered slow progressor patients (SPs. It is suspected that SP plasma has strongly neutralizing antibodies (NAb targeting specific HIV viral epitopes. METHODS: NAbs levels of 11 HIV-1-infected SPs were detected by PBMC-based neutralization assays. To investigate SP NAb epitope, this study used a biopanning approach to obtain mimotopes of HIV-1 that were recognized by SP plasma NAbs. IgG was purified from hightiter NAb SP plasma, and used as the ligand for three rounds of biopanning to select HIV-specific mimotopes from a phage-displayed random peptide library. Double-antibody sandwich ELISA, competitive inhibition assays, and peptide sequence analysis were used to evaluate the characteristics of phage-borne mimotopes. RESULTS: SPs had significantly more plasma neutralizing activity than typical progressors (TPs (p = 0.04. P2 and P9 plasma, which have highest-titer HIV-NAb, were selected as ligands for biopanning. After three rounds of biopanning, 48 phage clones were obtained, of which 22 clones were consistent with requirement, binding with HIV-1 positive plasma and unbinding with HIV-1 negative plasma. Compared with linear HIV-1 protein sequence and HIV-1 protein structure files, only 12 clones were possible linear mimotopes of NAbs. In addition, the C40 clone located in gp41 CHR was found to be a neutralizing epitope, which could inhibit pooled HIV-1 positive plasma reaction. CONCLUSION: Biopanning of serum IgG can yield mimotopes of HIV-1-related antigen epitopes. This methodology provides a basis for exploration into HIV-1-related antigen-antibody interactions and furthers NAb immunotherapy and vaccine design.

  20. Multifunctional Dendrimer-templated Antibody Presentation on Biosensor Surfaces for Improved Biomarker Detection.

    Science.gov (United States)

    Han, Hye Jung; Kannan, Rangaramanujam M; Wang, Sunxi; Mao, Guangzhao; Kusanovic, Juan Pedro; Romero, Roberto

    2010-02-08

    Dendrimers, with their well-defined globular shape and a high density of functional groups, are ideal nanoscale materials for templating sensor surfaces. This work exploits dendrimers as a versatile platform for capturing biomarkers with improved sensitivity and specificity. Synthesis, characterization, fabrication, and functional validation of the dendrimer-based assay platform are described. Bifunctional hydroxyl/thiol functionalized G4-polyamidoamine (PAMAM) dendrimer is synthesized and immobilized on to the polyethylene-glycol (PEG)-functionalized assay plate by coupling PEG-maleimide and dendrimer thiol groups. Simultaneously, part of the dendrimer thiol groups are converted to hydrazide functionalities. The resulting dendrimer-modified surface is coupled to the capture antibody in the Fc region of the oxidized antibody. This preserves the orientation flexibility of the antigen binding region (Fv) of the antibody. To validate the approach, the fabricated plates are further used as a solid phase for developing a sandwich type ELISA to detect IL-6 and IL-1β, important biomarkers for early stages of chorioamnionitis. The dendrimer-modified plate provides assays with significantly enhanced sensitivity, lower nonspecific adsorption, and a detection limit of 0.13 pg ml -1 for IL-6 luminol detection and 1.15 pg ml -1 for IL-1β TMB detection, which are significantly better than those for the traditional ELISA. The assays were validated in human serum samples from normal (non-pregnant) woman and pregnant women with pyelonephritis. The specificity and the improved sensitivity of the dendrimer-based capture strategy could have significant implications for the detection of a wide range of cytokines and biomarkers since the capture strategy could be applied to multiplex microbead assays, conductometric immunosensors and field effect biosensors.

  1. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L; Smid, B; Valicek, L; Jurak, E [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  2. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E.

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples usiOg ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC. (B.S.)

  3. A high affinity monoclonal antibody recognizing the light chain of human coagulating factor VII.

    Science.gov (United States)

    Sarial, Sheila; Asadi, Farzad; Jeddi-Tehrani, Mahmood; Hadavi, Reza; Bayat, Ali Ahmad; Mahmoudian, Jafar; Taghizadeh-Jahed, Masoud; Shokri, Fazel; Rabbani, Hodjattallah

    2012-12-01

    Factor VII (FVII) is a serine protease-coagulating element responsible for the initiation of an extrinsic pathway of clot formation. Here we generated and characterized a high affinity monoclonal antibody that specifically recognizes human FVII. Recombinant human FVII (rh-FVII) was used for the production of a monoclonal antibody using BALB/c mice. The specificity of the antibody was determined by Western blot using plasma samples from human, mouse, sheep, goat, bovine, rabbit, and rat. Furthermore, the antibody was used to detect transiently expressed rh-FVII in BHK21 cell line using Western blot and sandwich ELISA. A mouse IgG1 (kappa chain) monoclonal antibody clone 1F1-B11 was produced against rh-FVII. The affinity constant (K(aff)) of the antibody was calculated to be 6.4×10(10) M(-1). The antibody could specifically recognize an epitope on the light chain of hFVII, with no reactivity with factor VII from several other animals. In addition, transiently expressed rh-FVII in BHK21 cells was recognized by 1F1-B11. The high affinity as well as the specificity of 1F1-B11 for hFVII will facilitate the affinity purification of hFVII and also production of FVII deficient plasma and minimizes the risk of bovine FVII contamination when fetal bovine serum-supplemented media are used for production and subsequent purification of rh-FVII.

  4. UltramicroELISA para la detección de anticuerpos IgM anti M. leprae UltramicroELISA assay for the detection of human IgM antibodies to M. leprae

    Directory of Open Access Journals (Sweden)

    José Laferte

    1991-12-01

    Full Text Available La disponibilidad del sistema Ultramicroanalítico (SUMA y de un antígeno especie-específico del M. leprae obtenido mediante síntesis química, permitió la normalización y validación de un ultramicroELISA para la detección de anticuerpos IgM específicos a esta micobacteria. El análisis de 433 sueros de banco de sangre y 265 sueros usados para validar el método y clasificados en un grupo control de donantes de banco de sangre (100, un grupo de pacientes tuberculosos (50, un grupo de enfermos de lepra (65 y un grupo de contactos de estos enfermos (50, mostró la especificidad del ensayo para evidenciar la infección con el M. leprae. Los resultados obtenidos del estudio adicional de 140 muestras de suero de contactos de enfermos estuvieron estrechamente correlacionados (r = 0,98 con los resultados obtenidos por la técnica de microELISA convencional. La utilización del SUMA no solo permite un notable ahorro de reactivos si no además facilita la lectura, cálculo, validación y almacenamiento automático de los resultados.The availability of an ultramicroanalitic system (SUMA and specie-specific antigen of M. leprae obtained by chemical synthesis, have made possible the standardization and validation of an ultramicroELISA assay for detecting specific human IgM antibodies to this mycobacterium. The specificity of this test to demonstrate the infection with M. leprae was corroborated through a screening of 433 blood bank serum samples and other 265 from diferent groups (100, control group, 50 tuberculosis patients, 65 leprosy patients, 50 from household. The results obtained in the aditional study of 140 household sero showed a high correlation (r = 0.98 with the conventional microELISA method. The use of SUMA allows saving reagents and time since sample handling, plate reading, print out and storing the data are computer assisted.

  5. Chemiluminescence ELISA for the detection of oxidative DNA base damage using anti-8-hydroxy-2'-deoxyguanosine antibody. Application to the detection of irradiated foods

    International Nuclear Information System (INIS)

    Kikuchi, Masahiro; Funayama, Tomoo; Sakashita, Tetsuya; Satoh, Katsuya; Narumi, Issay; Kobayashi, Yashihiko; Gunawardane, Chaminda R.; Alam, Md. Khorshed; Dzomir, A. Zainuri Mohd.; Pitipanaarachchi, Ramya C.; Hamada, Nobuyuki; Wada, Seiichi

    2007-01-01

    Since ionizing radiation is used for sterilizing or lowering the microbial content of foods as a means of reducing food losses and securing food safety, the development of versatile detection methods of irradiated foods is necessary for appropriate management. In an effort to distinguish between irradiated and non-irradiated food, a method based on the detection of oxidative DNA base damage using the chemiluminescence enzyme-linked immunosorbent assay (ELISA) with anti-8-hydroxy-2'-deoxyguanosine antibody was developed. In the course of optimizing the reaction conditions for the ELISA, a 30-mer synthetic oligonucleotide containing 8-hydroxyguanine (8-oxoG) was used. Under the optimized conditions, the correlation between chemiluminescence intensity and 8-oxoG content in oligonucleotides was obtained. It was shown that this chemiluminescence ELISA method could be applied to chicken, beef and pork that were irradiated with over 3 kGy. Twenty milligrams of a loaf of meat was sufficient to distinguish between irradiated and non-irradiated meat by this method. (author)

  6. Friction stir welding (FSW of aluminium foam sandwich panels

    Directory of Open Access Journals (Sweden)

    M. Bušić

    2016-07-01

    Full Text Available The article focuses on the influence of welding speed and tool tilt angle upon the mechanical properties at the friction stir welding of aluminium foam sandwich panels. Double side welding was used for producing butt welds of aluminium sandwich panels applying insertion of extruded aluminium profile. Such insertion provided lower pressure of the tool upon the aluminium panels, providing also sufficient volume of the material required for the weldment formation. Ultimate tensile strength and flexural strength for three-point bending test have been determined for samples taken from the welded joints. Results have confirmed anticipated effects of independent variables.

  7. Covalent immobilisation of antibodies in Teflon-FEP microfluidic devices for the sensitive quantification of clinically relevant protein biomarkers.

    Science.gov (United States)

    Pivetal, Jeremy; Pereira, Filipa M; Barbosa, Ana I; Castanheira, Ana P; Reis, Nuno M; Edwards, Alexander D

    2017-03-13

    This study reports for the first time the sensitive colorimetric and fluorescence detection of clinically relevant protein biomarkers by sandwich immunoassays using the covalent immobilisation of antibodies onto the fluoropolymer surface inside Teflon®-FEP microfluidic devices. Teflon®-FEP has outstanding optical transparency ideal for high-sensitivity colorimetric and fluorescence bioassays, however this thermoplastic is regarded as chemically inert and very hydrophobic. Covalent immobilisation can offer benefits over passive adsorption to plastic surfaces by allowing better control over antibody density, orientation and analyte binding capacity, and so we tested a range of different and novel covalent immobilisation strategies. We first functionalised the inner surface of a 10-bore, 200 μm internal diameter FEP microcapillary film with high-molecular weight polyvinyl alcohol (PVOH) without changing the outstanding optical transparency of the device delivered by the matched refractive index of FEP and water. Glutaraldehyde immobilisation was compared with the use of photoactivated linkers and NHS-ester crosslinkers for covalently immobilising capture antibodies onto PVOH. Three clinically relevant sandwich ELISAs were tested against the cytokine IL-1β, the myocardial infarct marker cardiac troponin I (cTnI), and the chronic heart failure marker brain natriuretic peptide (BNP). Overall, glutaraldehyde immobilisation was effective for BNP assays, but yielded unacceptable background for IL-1β and cTnI assays caused by direct binding of the biotinylated detection antibody to the modified PVOH surface. We found NHS-ester groups reacted with APTES-treated PVOH coated fluoropolymers. This facilitated a novel method for capture antibody immobilisation onto fluoropolymer devices using a bifunctional NHS-maleimide crosslinker. The density of covalently immobilised capture antibodies achieved using PVOH/APTES/NHS/maleimide approached levels seen with passive adsorption

  8. EVALUATION OF AN O-ANTIGEN ELISA FOR SCREENING CATTLE HERDS FOR SALMONELLA-TYPHIMURIUM

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Bitsch, V.

    1995-01-01

    A total of 2585 serum samples from 62 dairy herds located in four different regions of Denmark were tested in an O-antigen (0:1,4,5,12)-based ELISA for the detection of antibodies against Salmonella typhimurium. Ten closed herds from an island with no reported occurrence of salmonellosis for seve......A total of 2585 serum samples from 62 dairy herds located in four different regions of Denmark were tested in an O-antigen (0:1,4,5,12)-based ELISA for the detection of antibodies against Salmonella typhimurium. Ten closed herds from an island with no reported occurrence of salmonellosis...... for several years, and 12 herds from a salmonella enzootic area which had had clinical outbreaks of S typhimurium were used to define a herd ELISA cut-off value. When herds with at least 5 per cent of the serum samples having an optical density of >0.5 were considered ELISA-positive, all 10 herds from...... the salmonellosis-free island were ELISA-negative, and all but one of the 12 S typhimurium-infected herds were ELISA-positive, which resulted in a herd test sensitivity of 0.92 and herd test specificity of 1.0. Eleven of the 12 S typhimurium-infected herds were negative in a blocking ELISA based on a monoclonal...

  9. Cystatin capture elisa immunodiagnosis of human fasciolosis at Chupaca-Junin Province

    International Nuclear Information System (INIS)

    Cornejo, W.; Alva, P.; Sevilla, C.; Huiza, A.; Universidad Nacional Mayor de San Marcos, Lima

    2003-01-01

    To determine the prevalence of human fasciolosis in an endemic area by means of an Enzyme-Linked Immunosorbent Assay (ELISA) using cystatin as a capture agent for the detection of specific antibodies to fasciola hepatica cysteine proteinases. An ELISA plate was sensitized with cystatin, incubated with excretory-secretory products of adult flukes, and followed by standard ELISA procedures. Clinical applicability of the cystatin capture ELISA for the immunodiagnosis of fasciolosis was tested with 200 serum samples of children and adults from an endemic area in Chupaca province, Junin department. Serum samples from the endemic area tested by cystatin capture ELISA showed 27/200 (13,5%) of positive cases. Fasciolosis remains a major health problem at Chupaca province, Junin department

  10. Establishment of sandwich ELISA for soluble alpha-Klotho measurement: Age-dependent change of soluble alpha-Klotho levels in healthy subjects.

    Science.gov (United States)

    Yamazaki, Yuji; Imura, Akihiro; Urakawa, Itaru; Shimada, Takashi; Murakami, Junko; Aono, Yukiko; Hasegawa, Hisashi; Yamashita, Takeyoshi; Nakatani, Kimihiko; Saito, Yoshihiko; Okamoto, Nozomi; Kurumatani, Norio; Namba, Noriyuki; Kitaoka, Taichi; Ozono, Keiichi; Sakai, Tomoyuki; Hataya, Hiroshi; Ichikawa, Shoji; Imel, Erik A; Econs, Michael J; Nabeshima, Yo-Ichi

    2010-07-30

    Alpha-Klotho (alphaKl) regulates mineral metabolism such as calcium ion (Ca(2+)) and inorganic phosphate (Pi) in circulation. Defects in mice result in clinical features resembling disorders found in human aging. Although the importance of transmembrane-type alphaKl has been demonstrated, less is known regarding the physiological importance of soluble-type alphaKl (salphaKl) in circulation. The aims of this study were: (1) to establish a sandwich ELISA system enabling detection of circulating serum salphaKl, and (2) to determine reference values for salphaKl serum levels and relationship to indices of renal function, mineral metabolism, age and sex in healthy subjects. We successively developed an ELISA to measure serum salphaKl in healthy volunteers (n=142, males 66) of ages (61.1+/-18.5year). The levels (mean+/-SD) in these healthy control adults were as follows: total calcium (Ca; 9.46+/-0.41mg/dL), Pi (3.63+/-0.51mg/dL), blood urea nitrogen (BUN; 15.7+/-4.3mg/dL), creatinine (Cre; 0.69+/-0.14mg/dL), 1,25 dihydroxyvitamin D (1,25(OH)(2)D; 54.8+/-17.7pg/mL), intact parathyroid hormone (iPTH; 49.2+/-20.6pg/mL), calcitonin (26.0+/-12.3pg/mL) and intact fibroblast growth factor (FGF23; 43.8+/-17.6pg/mL). Serum levels of salphaKl ranged from 239 to 1266pg/mL (mean+/-SD; 562+/-146pg/mL) in normal adults. Although salphaKl levels were not modified by gender or indices of mineral metabolism, salphaKl levels were inversely related to Cre and age. However, salphaKl levels in normal children (n=39, males 23, mean+/-SD; 7.1+/-4.8years) were significantly higher (mean+/-SD; 952+/-282pg/mL) than those in adults (mean+/-SD; 562+/-146, Plevel was notably lower than those of age-matched controls. We established a detection system to measure human serum salphaKl for the first time. Age, Ca and Pi seem to influence serum salphaKl levels in a normal population. This detection system should be an excellent tool for investigating salphaKl functions in mineral metabolism. Copyright

  11. Detection of anti-Toxoplasma gondii antibodies in experimentally and naturally infected non-human primates by Indirect Fluorescence Assay (IFA and indirect ELISA Detecção de anticorpos anti-Toxoplasma gondii por meio das técnicas de Imunofluorescência Indireta e ELISA Indireto em primatas experimentalmente e naturalmente infectados

    Directory of Open Access Journals (Sweden)

    Andréa Bouer

    2010-03-01

    Full Text Available The Indirect Fluorescence Assay (IFA and the indirect ELISA were comparatively used to detect IgG and IgM antibodies for Toxoplasma gondii in experimentally and naturally infected primates. In the experimentally infected group, antibodies of diagnostic value were detected at day 9 post-infection (PI with the IFA (IgG and IgM and with IgG-ELISA. IgM-ELISA detected antibodies for T. gondii starting at day 3 PI until the end of the experiment (102 days PI. Of the 209 naturally infected sera tested, from many zoos of State of Sao Paulo, 64.59 and 67.94% were positive in the IgG-IFA test and IgG-ELISA respectively. IgM-ELISA test detected seropositivity in 52.63% of the sera although IgM-IFA test detected it in only in 0.96% of the samples. The differential toxoplasmosis diagnosis was accomplished with Neospora caninum by IFA, observing 61 (29.2% seropositive animals for this parasite and 149 (70.8% negative. Sixty animals were positive for both T. gondii and N. caninum. Pneumonia, splenomegaly, and intestinal ulcers were macroscopically observed. Unremarkable interstitial pneumonia, enteritis, colitis, splenitis, and glomerulitis were microscopically observed. The immunohistochemical stain could not detect the presence of T. gondii in the tissues of the animals infected experimentally.Detectou-se anticorpos das classes IgG e IgM anti-Toxoplasma gondii em primatas experimentalmente e naturalmente infectados, utilizando-se como técnicas comparativas a RIFI e o ELISA-teste. No grupo dos primatas experimentalmente infectados, anticorpos de valor diagnóstico foram detectados a partir do 9º dia de infecção tanto na RIFI (IgG e IgM como no ELISA-IgG. O ELISA IgM detectou anticorpos a partir do 3º dia de infecção até o final do experimento (102 dias pós-infecção. Dos 209 soros dos primatas naturalmente infectados, de diversos zoológicos do Estado de São Paulo, 64,59 e 67,94% mostraram-se positivos na RIFI-IgG e no ELISA-IgG, respectivamente. O

  12. IgA anti-Actin antibodies in children with celiac disease: comparison of immunofluorescence with Elisa assay in predicting severe intestinal damage

    Directory of Open Access Journals (Sweden)

    Mora Stefano

    2010-03-01

    Full Text Available Abstract Background Previous studies have demonstrated that the presence of serum IgA antibodies against actin filaments (AAA in patients with celiac disease (CD is strongly associated with mucosal damage and severe degrees of villous atrophy. The aims of the present study were (1 to verify the effectiveness of IgA-AAA in newly diagnosed CD patients in a clinical setting (2 to compare the immunofluorescence assay with ELISA assay; (3 to compare the correlation of our IgA anti-tissue transglutaminase antibodies (tTG-Ab class with mucosal intestinal lesions. Methods 90 patients underwent endoscopy and multiple biopsies for suspected CD on the basis of symptoms, in presence of positive tTG-Ab tests. Twenty biopsied and 25 not-biopsied subjects with negative tTG-Ab were tested as control groups. IgA-AAA assays were performed by indirect immunofluorescence using rat epithelial intestinal cells, and by ELISA with a commercial kit. tTG-Ab assay was a radio-binding assay. Intestinal specimens were collected by upper endoscopy and the histological study was done according to the Marsh's classification modified by Oberhuber (M/O. Auto-antibodies assays and histological evaluation have been performed blindly by skilled operators. Results CD diagnosis was confirmed in 82 patients (type I M/O in 2 patients, IIIA in 18 patients, IIIB in 29 patients and IIIC in 33 patients. Two patients with type 1 lesion in presence of positive tTG-Ab and abdominal complaints, started a gluten free diet. The rate of IgA-AAA positivity (sensitivity by IFI and ELISA in histologically proven celiac disease patients, were 5.5% and 25% patients in IIIA, 27.5% and 34.4% patients in IIIB, 78.8% and 75% in IIIC patients, respectively. Patients with normal or nearly normal mucosa, regardless of tTG-Ab status, presented negative IgA-AAA IFI assay. On the other hand, 1 patient with normal mucosa but positive tTG-Ab, also presented positive IgA-AAA ELISA. All healthy non biopsied

  13. Production of monoclonal antibodies and development of a quantitative immuno-polymerase chain reaction assay to detect and quantify recombinant Glutathione S-transferase.

    Science.gov (United States)

    Abud, J E; Luque, E H; Ramos, J G; Rodriguez, H A

    2017-07-01

    GST-tagged proteins are important tools for the production of recombinant proteins. Removal of GST tag from its fusion protein, frequently by harsh chemical treatments or proteolytic methods, is often required. Thus, the monitoring of the proteins in tag-free form requires a significant effort to determine the remnants of GST during purification process. In the present study, we developed both a conventional enzyme-linked immunosorbent assay (ELISA) and an immuno-polymerase chain reaction (IPCR) assay, both specific for detection of recombinant GST (rGST). rGST was expressed in Escherichia coli JM109, using a pGEX4T-3 vector, and several anti-rGST monoclonal antibodies were generated using hybridoma technology. Two of these were rationally selected as capture and detection antibodies, allowing the development of a sandwich ELISA with a limit of detection (LOD) of 0.01 μg/ml. To develop the rGST-IPCR assay, we selected "Universal-IPCR" format, comprising the biotin-avidin binding as the coupling system. In addition, the rGST-IPCR was developed in standard PCR tubes, and the surface adsorption of antibodies on PCR tubes, the optimal neutravidin concentrations, the generation of a reporter DNA and the concentration effect were studied and determined. Under optimized assay conditions, the rGST-IPCR assay provided a 100-fold increase in the LOD as well as an expanded working range, in comparison with rGST-ELISA. The proposed method exhibited great potentiality for application in several fields in which measurement of very low levels of GST is necessary, and might provide a model for other IPCR assays. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Effect of days in milk and milk yield on testing positive in milk antibody ELISA to Mycobacterium avium subsp. paratuberculosis in dairy cattle

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2012-01-01

    Milk samples are becoming more used as a diagnostic specimen for assessment of occurrence of antibodies to Mycobacterium avium subsp. paratuberculosis (MAP). This study assessed the effect of days in milk (DIM) and milk yield on testing positive in a commercial MAP specific milk antibody ELISA...... from the first couple of DIM should be excluded from MAP testing until further information on their significance is established. Milk yield also had a significant effect on odds of testing positive due to its diluting effect. Inclusion of milk yield in the interpretation of test results could improve...... among 222,774 Danish Holstein cows. Results showed that odds of testing positive on 1-2 DIM were 9-27 times higher than the rest of lactation, where the chance of testing positive varied less. The reason is most likely a high concentration of non-specific antibodies in colostrum. Consequently, samples...

  15. Evaluation of methods to reduce background using the Python-based ELISA_QC program.

    Science.gov (United States)

    Webster, Rose P; Cohen, Cinder F; Saeed, Fatima O; Wetzel, Hanna N; Ball, William J; Kirley, Terence L; Norman, Andrew B

    2018-05-01

    Almost all immunological approaches [immunohistochemistry, enzyme-linked immunosorbent assay (ELISA), Western blot], that are used to quantitate specific proteins have had to address high backgrounds due to non-specific reactivity. We report here for the first time a quantitative comparison of methods for reduction of the background of commercial biotinylated antibodies using the Python-based ELISA_QC program. This is demonstrated using a recombinant humanized anti-cocaine monoclonal antibody. Several approaches, such as adjustment of the incubation time and the concentration of blocking agent, as well as the dilution of secondary antibodies, have been explored to address this issue. In this report, systematic comparisons of two different methods, contrasted with other more traditional methods to address this problem are provided. Addition of heparin (HP) at 1 μg/ml to the wash buffer prior to addition of the secondary biotinylated antibody reduced the elevated background absorbance values (from a mean of 0.313 ± 0.015 to 0.137 ± 0.002). A novel immunodepletion (ID) method also reduced the background (from a mean of 0.331 ± 0.010 to 0.146 ± 0.013). Overall, the ID method generated more similar results at each concentration of the ELISA standard curve to that using the standard lot 1 than the HP method, as analyzed by the Python-based ELISA_QC program. We conclude that the ID method, while more laborious, provides the best solution to resolve the high background seen with specific lots of biotinylated secondary antibody. Copyright © 2018. Published by Elsevier B.V.

  16. Double-antibody solid-phase radioimmunoassay: a simplified phase-separation procedure applied to various ligands

    International Nuclear Information System (INIS)

    Tevaarwerk, G.J.M.; Boyle, D.A.; Hurst, C.J.; Anguish, I.; Uksik, P.

    1980-01-01

    The purpose was to develop a simplified and reliable method of separating free from antibody-bound ligand using a precipitating antibody linked to a cellulose derivative. Dose-response curves and control sera were set up in parallel for various pituitary and placental polypeptides, steroid hormones, insulin, glucagon, triiodothyronine, thyroxine, angiotensin I, calcitonin, gastrin, cyclic AMP, and digoxin. After first-antibody reactions had reached equilibrium, free and bound ligand were separated using a double-antibody solid-phase system in parallel with conventional methods, including dextran-coated charcoal, double-antibody precipitation, single-antibody solid phase, organic solvents, salt precipitation, and anion-exchange resins. The effect of variations in temperature, incubation time, protein content, pH, and amount of separating material added were studied. The results showed that separation was complete within 1 hr for small ligand molecules and within 2 hr for larger ones. Dose-response curves and control-sera results closely paralleled those obtained with conventional methods. The method was not affected by moderate variations in incubation variables. Nonspecific binding was less than 3% in all assays, while intra-assay and interassay coefficients of variation were similar to those obtained with conventional phase-separation methods. It is concluded that the method is a simple and rapid alternative phase-separation system. It has the advantage of being free from common nonspecific intersample variations, and can be applied to any assay system based on rabbit or guinea pig antibodies without preliminay time- or reagent-consuming titration or adjustments to establish optimum phase-separating conditions

  17. Comparison of R5 and G12 Antibody-Based ELISA Used for the Determination of the Gluten Content in Official Food Samples

    Directory of Open Access Journals (Sweden)

    Rupert Hochegger

    2015-11-01

    Full Text Available Celiac Disease (CD is one of the most common food intolerances. It comes along with serious damage of the mucosa in the small intestine and is caused by the storage proteins—termed “gluten”—of wheat, rye, barley and possibly oats. Sensitive individuals need to stick to a strict gluten-free diet. The gluten level in food products labeled as “gluten-free”, must not exceed 20 mg/kg. It is obvious that effective test methods are needed to accurately determine the gluten concentration in foods. The determination of the presence of gluten in foodstuffs is mainly done by means of an immunochemical method called ELISA (enzyme-linked immunosorbent assay. To check the suitability of a G12 antibody-based gluten detection kit for its use in official control systems a number of routine samples were tested in parallel with two different test kits, as would be done in a routine lab. The determination of the gluten content was performed on samples entering the official laboratory including samples from official control plans, commercially available and private samples to request gluten-free labels. The results obtained with the G12 antibody ELISA assay were comparable to the official R5 method. A validation of the two different methods was not part of this study.

  18. A comparative study of an elisa test and an indirect immunofluorescence test for serological diagnosis of Babesia bovis infection

    International Nuclear Information System (INIS)

    Martins, J.R.; Cheong, F.H.; Correa, B.L.; Radley, D.E.; Cereser, V.H.

    1998-01-01

    Detection of antibodies to Babesia bovis in cattle is essential for the understanding of the epidemiology of babesiosis and this study was concerned with comparing the indirect fluorescent antibody with the ELISA. Both assays gave rise to 100% sensitivity whilst the ELISA was shown to be marginally more specific at 98%. The ease of use and low cost of the ELISA would make it the more obvious choice in conducting future serological surveys for this parasite. (author)

  19. Quantitation of parasite-specific human IgG and IgE in sera: evaluation of solid-phase RIA and ELISA methodology

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, R G [Johns Hopkins Univ., Baltimore, MD (USA). Dept. of Medicine; Hussain, R; Ottesen, E A [National Inst. of Allergy and Infectious Diseases, Bethesda, MD (USA); Adkinson, Jr, N F [Johns Hopkins Univ., Baltimore, MD (USA). School of Medicine

    1981-07-17

    The authors have developed a non-competitive solid-phase radioimmunoassay (SPRIA) to quantitate both human IgE and IgG antibodies against soluble adult antigens of Brugia malayi (B.m.), a filarial parasite causing extensive infection throughout the tropics. Previously enzyme-linked immunosorbent assays (ELISA) had been used to detect ..mu..g/ml levels of IgG anti-B.m., but IgE antibodies were difficult to detect in this system. Since the SPRIA successfully quantitates both IgG and IgE anti-B.m., they sought to examine the reasons for the SPRIA's apparent superiority in detecting IgE anti-B.m. by extracting specific IgG from sera with high levels of IgE and IgG anti-B.m. antibodies. IgE anti-B.m. was then quantitated in these sera using both the SPRIA and ELISA methods. Results indicate that IgG anti-B.m. does not interfere with detection of specific IgE antibody in the SPRIA but does interfere in the ELISA. While ELISA permits detection of IgE anti-B.m. in the absence of competing IgG anti-B.m., as levels of specific IgG increase, the IgE is no longer detectable. These differences between SPRIA and ELISA can be explained by the SPRIA's antigen excess conditions which assure that there are sufficient antigens both to detect all anti-B.m. antibodies present in the serum and to adequately represent all antigen specificities in the crude B.m. extract. Their findings commend the use of SPRIA methods over ELISA in assessment of B.m.-specific IgE antibody in filariasis and indicate a potential role for SPRIA methods in absolute quantitation of specific serum antibodies.

  20. Enzyme-linked immunosorbent assay (ELISA for measles antibody: a comparison with haemagglutination inhibition, immunofluorescence and plaque neutralization tests Reação imunoenzimática (ELISA para detecção de anticorpos para o vírus do sarampo: comparação com reações de inibição da hema-glutinação, imunofluorescência indireta e neutralização de placas

    Directory of Open Access Journals (Sweden)

    Vanda Akico Ueda Fick de Souza

    1991-02-01

    Full Text Available An enzyme-linked immunosorbent assay (ELISA for measles antibodies was compared with Plaque Neutralization (PRN, Haemagglutination inhibition (HI and Fluorescent antibody (IFA tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%. IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.A reação imunoenzimática (ELISA para determinação de anticorpos para o vírus do sarampo foi comparada com a reação de neutralização de placas (RNP, inibição da hemaglutinação (RIH e imunofluorescência indireta (RIF. Das 179 amostras positivas pela RNP, somente 2, com títulos iguais a 8, se apresentaram negativas por ELISA (copositividade de 98.9%. A RIF e RIH apresentaram, respectivamente, copositividade de 93.3 e 82.7%. ELISA apresentou sensibilidade equivalente à complexa RNP, boa reprodutibilidade e representa uma alternativa para a detecção de baixos títulos de anticorpos contra o sarampo.

  1. Evaluation of the antibody-detection ELISA using plates precoated with denatured T. congolense and T. vivax antigens for monitoring tsetse and trypanosomosis control in Zambia

    International Nuclear Information System (INIS)

    Machila, N.; Sinyangwe, L.; Eisler, M.C.

    2000-01-01

    An evaluation of the indirect enzyme-linked immunosorbent assay (ELISA) for the detection of anti-trypanosomal antibodies in bovine serum was conducted using ELISA plates pre-coated with denatured T. congolense and T. vivax antigen. The study was conducted on 280 samples from a parasitologically positive cattle population and 200 samples from a negative cattle population. The overwhelming majority of trypanosome infections in the parasitologically positive cattle were T. congolense. The Ab-ELISA was able to discriminate between the negative and positive cattle populations, at an optimum cut-off point of 40% positivity (T. congolense antigen), with 89% sensitivity and 86% specificity; and for the T. vivax antigen, the optimum cut-off point was at 30%, with 81% sensitivity and 70% specificity. However, the optical densities (OD) and percentage positivity (PP) values for sera from both the reference positive and negative cattle populations were unacceptably high particularly in the ELISA using T. congolense antigen. Furthermore the quality control sera used in the assay appear to have inappropriately low OD and PP values by comparison to typical sera from the reference positive and negative cattle populations. It is suggested that these ELISA's be re-titrated using more appropriate quality assurance sera. This should result in OD and PP values for sera from the reference populations failing within acceptable ranges. (author)

  2. Comparison of DOT-ELISA and Standard-ELISA for Detection of the Vibrio cholerae Toxin in Culture Supernatants of Bacteria Isolated from Human and Environmental Samples.

    Science.gov (United States)

    Meza-Lucas, Antonio; Pérez-Villagómez, María-Fernanda; Martínez-López, José-Patricio; García-Rodea, Ricardo; Martínez-Castelán, María-Guadalupe; Escobar-Gutiérrez, Alejandro; de-la-Rosa-Arana, Jorge-Luis; Villanueva-Zamudio, Altagracia

    2016-09-01

    A comparison of DOT-ELISA and Standard-ELISA was made for detection of Vibrio cholerae toxin in culture supernatants of bacteria isolated from human and environmental samples. A total of 293 supernatants were tested in a double blind assay. A correlation of 100 % was obtained between both techniques. The cholera toxin was found in 20 Inaba and 3 Ogawa strains. Positive samples were from seafood (17 samples), potable water (1 sample) and sewage (5 samples). The DOT-ELISA was useful as the standard-ELISA to confirm the presence of cholera toxin in the environmental samples.

  3. [Efficacy of absorbance ratio of ELISA antibodies [corrected] for hepatitis C virus of 3th generation in the prediction of viremia evaluated by PCR].

    Science.gov (United States)

    Vázquez-Avila, Isidro; Vera-Peralta, Jorge Manuel; Alvarez-Nemegyei, José; Rodríguez-Carvajal, Otilia

    2007-01-01

    In order to decrease the burden of suffering and the costs derived from confirmatory molecular assays, a better strategy is badly needed to decrease the rate of false positive results of the enzyme-linked immunoassay (ELISA) for detection of hepatitis C virus (HCV) antibodies (Anti). To establish the best cutoff of the S/CO rate in subjects with a positive result of a microparticule, third generation ELISA assay for Anti-HCV, for predicting viremia as detected by polymerase chain reaction (PCR) assay. Using the result of the PCR assay as "gold standard", a ROC curve was build with the results of the S/CO rate values in subjects with a positive result for ELISA HCV assay. Fifty two subjects (30 male, 22 female, 40 +/- 12.5 years old) were included. Thirty four (65.3%) had a positive RNA HCV PCR assay. The area under the curve was 0.99 (95% CI: 0.98-1.0). The optimal cutoff for the S/CO rate was established in 29: sensitivity: 97%; specificity: 100%: PPV: 100%; NPV: 94%. Setting the cutoff of the S/CO in 29 results in a high predictive value for viremia as detected by PCR in subjects with a positive ELISA HVC assay. This knowledge may result in a better decision taking for the clinical follow up of those subjects with a positive result in the ELISA screening assay for HCV infection.

  4. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    Science.gov (United States)

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  5. Purification of HBsAg produced by the human hepatoma cell line PLC/PRE/5 by affinity chromatography using monoclonal antibodies and application for ELISA diagnostic.

    Science.gov (United States)

    Merten, O W; Reiter, S; Scheirer, W; Katinger, H

    1983-01-01

    The human cell line PLC/PRF/5 (5) was used for the production of hepatitis B surface antigen subtype ad (HBsAg ad) and purified by affinity chromatography (AC) with monoclonal antibodies (mAb). mAb to HBsAg from mouse ascites have been purified by Protein A - AC prior coupling to AH-Sepharose 4B (Pharmacia). The combined procedure of ammonium-sulphate-precipitation of HBsAg from culture supernatants and immunosorbent-AC leads to approx. 700-fold purification. ELISA results using the mAb and the HBsAg for diagnostics of human serum, positive for anti-HBsAg-antibodies correlate with the RIA (AUSAB, Abbott).

  6. Early antihepatitis C virus response with second-generation C200/C22 ELISA

    NARCIS (Netherlands)

    van der Poel, C. L.; Bresters, D.; Reesink, H. W.; Plaisier, A. A.; Schaasberg, W.; Leentvaar-Kuypers, A.; Choo, Q. L.; Quan, S.; Polito, A.; Houghton, M.

    1992-01-01

    Detection of early antibody to hepatitis C virus (HCV) by a new second-generation C200/C22 anti-HCV enzyme-linked immunosorbent assay (ELISA) and a four-antigen recombinant immunoblot assay (4-RIBA) was compared with the first-generation anti-HCV C100 ELISA using sequential serum samples of 9

  7. Improved detection of equine antibodies against Sarcocystis neurona using polyvalent ELISAs based on the parasite SnSAG surface antigens.

    Science.gov (United States)

    Yeargan, Michelle R; Howe, Daniel K

    2011-02-28

    Equine protozoal myeloencephalitis (EPM) is a common neurologic disease of horses that is caused by the apicomplexan pathogen Sarcocystis neurona. To help improve serologic diagnosis of S. neurona infection, we have modified existing enzyme-linked immunosorbent assays (ELISAs) based on the immunogenic parasite surface antigens SnSAG2, SnSAG3, and SnSAG4 to make the assays polyvalent, thereby circumventing difficulties associated with parasite antigenic variants and diversity in equine immune responses. Two approaches were utilized to achieve polyvalence: (1) mixtures of the individual recombinant SnSAGs (rSnSAGs) were included in single ELISAs; (2) a collection of unique SnSAG chimeras that fused protein domains from different SnSAG surface antigens into a single recombinant protein were generated for use in the ELISAs. These new assays were assessed using a defined sample set of equine sera and cerebrospinal fluids (CSFs) that had been characterized by Western blot and/or were from confirmed EPM horses. While all of the polyvalent ELISAs performed relatively well, the highest sensitivity and specificity (100%/100%) were achieved with assays containing the rSnSAG4/2 chimera (Domain 1 of SnSAG4 fused to SnSAG2) or using a mixture of rSnSAG3 and rSnSAG4. The rSnSAG4 antigen alone and the rSnSAG4/3 chimera (Domain 1 of SnSAG4 fused to Domain 2 of SnSAG3) exhibited the next best accuracy at 95.2% sensitivity and 100% specificity. Binding ratios and percent positivity (PP) ratios, determined by comparing the mean values for positive versus negative samples, showed that the most advantageous signal to noise ratios were provided by rSnSAG4 and the rSnSAG4/3 chimera. Collectively, our results imply that a polyvalent ELISA based on SnSAG4 and SnSAG3, whether as a cocktail of two proteins or as a single chimeric protein, can give optimal results in serologic testing of serum or CSF for the presence of antibodies against S. neurona. The use of polyvalent SnSAG ELISAs will

  8. Produksi dan Karakterisasi Antibodi Monoklonal Anti-Cysticercus cellulosae (PRODUCTION AND CHRACTERIZATION OF MONOCLONAL ANTIBODIES AGAINST CYSTICERCUS CELLULOSAE

    Directory of Open Access Journals (Sweden)

    Ida Bagus Ngurah Swacita

    2015-10-01

    Full Text Available The purpose of this study is to make a monoclonal antibody against- Cysticercus cellulosae and itscharacterization. Samples antigen prepared from T. solium larvae (C. cellulosae was then used to immunizeBalb/c. The immune response of mice assessed by ELISA test, then the lymphocytes of mice used for theproduction of monoclonal antibodies (MoAb. Origin lymphocytes of mice that produce antibodies againstC. cellulosae antigen, fused with myeloma cells (NS1. Results fusion of two cells produces hybrid cellscalled hybridomas; cells are then screened by ELISA test. Hybridoma cells that produce only MoAb, usedto produce large quantities in vitro. Characterization of MoAb against-C.cellulosae was tested by usingELISA and Western blotting. Mice were immunized with C.cellulosae antigen showed an immune responseproducing antibodies to C.cellulosae. Based on the results of fusion, produced a total of 51 hybridoma cellclones and after being screened, only three clones of hybridoma cells that produced MoAb against–C.cellulosae. MoAb produced, named after the hole where the growth of the ELISA micro plate, the BE6,BE7, and EE9. Characteristics of this MoAb capable of tracking cellulosae of fluid larvae and recognizeantigen protein bands with molecular weight 78kDa.

  9. Evaluation Of Antibody Elisa, Coproscopy And Serum Enzyme ...

    African Journals Online (AJOL)

    Le titrage avec immunoadsorbant lié à une enzyme (ELISA), la sédimentation fécale et les tests de l'action de l'enzyme du sérum ont été faits sur des échantillons de fèces et de sérum recueillis de 134 bovins (55 positifs et 79 négatifs pour les lésions dues à la douve du foie) lors de l'inspection de viande en Ethiopie.

  10. Rabbit haemorrhagic disease: advantages of cELISA in assessing immunity in wild rabbits (Oryctolagus cuniculus).

    Science.gov (United States)

    Zheng, Tao; Parkes, John P

    2011-12-15

    Rabbit haemorrhagic disease (RHD) is an acute fatal disease of domestic and wild European rabbits (Oryctolagus cuniculus) caused by RHD virus (RHDV). Accurate assessment of immunity is of great importance for the conservation and control of wild rabbits. We evaluated a competitive ELISA (cELISA) against isotype ELISAs for assessing the protective immunity against the disease by challenging 50 wild-caught rabbits with a lethal dose of RHDV. Death or survival to the challenge was used as a criterion to determine the performance characteristics of the assay for the assessment of immunity in rabbits. At 1:10 dilution, a serum exhibiting ≥ 25% inhibition (1:10(25)) was regarded as the presence of RHDV-specific antibodies. Eleven of 16 (68.8%) rabbits with antibodies at 1:10(25) (<1:40) died of RHD. When the cut-off was moved from 25% to 50% inhibition (1:10(50)) at 1:10 serum dilution, the assay sensitivity, specificity and accuracy for the protective immunity were improved from 84%, 54.2% and 69.4% to 84%, 100% and 91.8%, respectively. We also demonstrated at the epitope amino acid sequence level why the presence of the RHDV-cross reactive benign rabbit calicivirus, which interfered with isotype ELISAs, had little impact on the specificity of the cELISA for the diagnosis of RHDV infection. The presence of RHDV-specific antibody at 1:10(50) by the cELISA is a reliable indicator for the protective immunity. In contrast to isotype ELISAs, the cELISA is a valuable specific tool for monitoring the herd immunity to RHD for the conservation and management of wild rabbits in the field. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Indirect ELISA based on Hendra and Nipah virus proteins for the detection of henipavirus specific antibodies in pigs.

    Directory of Open Access Journals (Sweden)

    Kerstin Fischer

    Full Text Available Hendra virus (HeV and Nipah virus (NiV belong to the genus Henipavirus in the family Paramyxoviridae. Henipavirus infections were first reported in the 1990's causing severe and often fatal outbreaks in domestic animals and humans in Southeast Asia and Australia. NiV infections were observed in humans in Bangladesh, India and in the first outbreak in Malaysia, where pigs were also infected. HeV infections occurred in horses in the North-Eastern regions of Australia, with singular transmission events to humans. Bats of the genus Pteropus have been identified as the reservoir hosts for henipaviruses. Molecular and serological indications for the presence of henipa-like viruses in African fruit bats, pigs and humans have been published recently. In our study, truncated forms of HeV and NiV attachment (G proteins as well as the full-length NiV nucleocapsid (N protein were expressed using different expression systems. Based on these recombinant proteins, Enzyme-linked Immunosorbent Assays (ELISA were developed for the detection of HeV or NiV specific antibodies in porcine serum samples. We used the NiV N ELISA for initial serum screening considering the general reactivity against henipaviruses. The G protein based ELISAs enabled the differentiation between HeV and NiV infections, since as expected, the sera displayed higher reactivity with the respective homologous antigens. In the future, these assays will present valuable tools for serosurveillance of swine and possibly other livestock or wildlife species in affected areas. Such studies will help assessing the potential risk for human and animal health worldwide by elucidating the distribution of henipaviruses.

  12. Photoluminescence of double core/shell infrared (CdSeTe)/ZnS quantum dots conjugated to Pseudo rabies virus antibodies

    Science.gov (United States)

    Torchynska, T. V.; Casas Espinola, J. L.; Jaramillo Gómez, J. A.; Douda, J.; Gazarian, K.

    2013-06-01

    Double core CdSeTe/ZnS quantum dots (QDs) with emission at 800 nm (1.60 eV) have been studied by photoluminescence (PL) and Raman scattering methods in the non-conjugated state and after the conjugation to the Pseudo rabies virus (PRV) antibodies. The transformation of PL spectra, stimulated by the electric charge of antibodies, has been detected for the bioconjugated QDs. Raman scattering spectra are investigated with the aim to reveal the CdSeTe core compositions. The double core QD energy diagrams were designed that help to analyze the PL spectra and their transformation at the bioconjugation. It is revealed that the interface in double core QDs has the type II quantum well character that permits to explain the near IR optical transition (1.60 eV) in the double core QDs. It is shown that the essential transformation of PL spectra is useful for the study of QD bioconjugation with specific antibodies and can be a powerful technique in early medical diagnostics.

  13. Characterization of antibodies specific for UV-damaged DNA by ELISA

    Energy Technology Data Exchange (ETDEWEB)

    Eggset, G; Volden, G; Krokan, H

    1987-04-01

    The specificity of affinity purified antibodies raised against UV-irradiated DNA was examined using an enzyme-linked immunosorbent assay. DNA irradiated with UV doses higher than needed for saturation with pyrimidine dimers bound increasing amounts of antibody. Photosensitized DNA, containing high amounts of pyrimidine dimers, showed very poor binding of antibody. When UV-irradiated DNA was given a second dose of 340-nm UV light, the binding of antibodies was inhibited. Taken together, this indicates a major specificity for (6-4)-photoproducts, which are photochemically reversed by UV light in the 340-nm region. The antibodies also showed little but detectable binding to pyrimidine glycols produced in DNA by oxidation with OsO/sub 4/. Previously, we have used these antibodies for the detection of UV-induced DNA damage and its repair in human skin in vivo. These findings indicate that (6-4)-photoproducts, considered highly mutagenic, are repaired in human skin.

  14. Characterization of antibodies specific for UV-damaged DNA by ELISA

    International Nuclear Information System (INIS)

    Eggset, G.; Volden, G.; Krokan, H.; Norsk Hydro Research Centre, Porsgrunn

    1987-01-01

    The specificity of affinity purified antibodies raised against UV-irradiated DNA was examined using an enzyme-linked immunosorbent assay. DNA irradiated with UV doses higher than needed for saturation with pyrimidine dimers bound increasing amounts of antibody. Photosensitized DNA, containing high amounts of pyrimidine dimers, showed very poor binding of antibody. When UV-irradiated DNA was given a second dose of 340-nm UV light, the binding of antibodies was inhibited. Taken together, this indicates a major specificity for (6-4)-photoproducts, which are photochemically reversed by UV light in the 340-nm region. The antibodies also showed little but detectable binding to pyrimidine glycols produced in DNA by oxidation with OsO 4 . Previously, we have used these antibodies for the detection of UV-induced DNA damage and its repair in human skin in vivo. These findings indicate that (6-4)-photoproducts, considered highly mutagenic, are repaired in human skin. (author)

  15. The quantitation of parasite-specific human IgG and IgE in sera: evaluation of solid-phase RIA and ELISA methodology

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Adkinson, N.F. Jr.

    1981-01-01

    The authors have developed a non-competitive solid-phase radioimmunoassay (SPRIA) to quantitate both human IgE and IgG antibodies against soluble adult antigens of Brugia malayi (B.m.), a filarial parasite causing extensive infection throughout the tropics. Previously enzyme-linked immunosorbent assays (ELISA) had been used to detect μg/ml levels of IgG anti-B.m., but IgE antibodies were difficult to detect in this system. Since the SPRIA successfully quantitates both IgG and IgE anti-B.m., they sought to examine the reasons for the SPRIA's apparent superiority in detecting IgE anti-B.m. by extracting specific IgG from sera with high levels of IgE and IgG anti-B.m. antibodies. IgE anti-B.m. was then quantitated in these sera using both the SPRIA and ELISA methods. Results indicate that IgG anti-B.m. does not interfere with detection of specific IgE antibody in the SPRIA but does interfere in the ELISA. While ELISA permits detection of IgE anti-B.m. in the absence of competing IgG anti-B.m., as levels of specific IgG increase, the IgE is no longer detectable. These differences between SPRIA and ELISA can be explained by the SPRIA's antigen excess conditions which assure that there are sufficient antigens both to detect all anti-B.m. antibodies present in the serum and to adequately represent all antigen specificities in the crude B.m. extract. Their findings commend the use of SPRIA methods over ELISA in assessment of B.m.-specific IgE antibody in filariasis and indicate a potential role for SPRIA methods in absolute quantitation of specific serum antibodies. (Auth.)

  16. A novel indirect ELISA for diagnosis of dengue fever

    Directory of Open Access Journals (Sweden)

    Rohan Narayan

    2016-01-01

    Full Text Available Background & objectives: Dengue fever (DF is associated with significant morbidity and mortality in the tropical and sub-tropical regions of the world. Since there are no effective antiviral drugs for treatment, clinicians often rely on the accurate diagnosis of dengue fever to begin supportive therapy at early stages of the illness. The objective of this study was to develop an in-house dengue virus serotype 2 (DENV-2 non-structural protein- 5 (NS5 based indirect ELISA. Methods: DENV-2 was raised in Vero cells and the viral proteins were separated and subsequently the NS5 protein was eluted. Serum samples from primary and secondary dengue fever patients; and acute and convalescent samples from Japanese encephalitis (JE and West Nile virus (WNV cases were used to validate the ELISA. Results: The assay was found to be 100 per cent specific in detecting DENV-2 specific antibodies from patient′s serum. However, in terms of sensitivity, the assay could detect IgM antibodies only from 90 per cent of the primary dengue samples. The IgM/IgG ratio of the primary and secondary samples was 7.24 and 0.64, respectively. Interpretation & conclusions: The results indicate that the DENV-2 NS5 ELISA is dengue group specific and can be used to differentiate dengue infection from other circulating Flavivirus infections. This NS5 ELISA can also be used to distinguish between primary and secondary dengue fever on the basis of IgM/IgG ratios. Further studies with larger sample sizes and different DENV serotypes are required to validate the ELISA.

  17. Development of a Monoclonal Antibody-Based icELISA for the Detection of Ustiloxin B in Rice False Smut Balls and Rice Grains

    Directory of Open Access Journals (Sweden)

    Xiaoxiang Fu

    2015-08-01

    Full Text Available Rice false smut is an emerging and economically-important rice disease caused by infection by the fungal pathogen Villosiclava virens. Ustiloxin B is an antimitotic cyclopeptide mycotoxin isolated from the rice false smut balls that formed in the pathogen-infected rice spikelets. A monoclonal antibody (mAb designated as mAb 1B5A10 was generated with ustiloxin B—ovalbumin conjugate. A highly-sensitive and specific indirect competitive enzyme-linked immunosorbent assay (icELISA was then developed. The median inhibitory concentration (IC50 of the icELISA was 18.0 ng/mL for the detection of ustiloxin B; the limit of detection was 0.6 ng/mL, and the calibration range was from 2.5 to 107.4 ng/mL. The LOD/LOQ values of the developed ELISA used for the determination of ustiloxin B in rice false smut balls and rice grains were 12/50 μg/g and 30/125 ng/g, respectively. The mAb 1B5A10 cross-reacted with ustiloxin A at 13.9% relative to ustiloxin B. Average recoveries of ustiloxin B ranged from 91.3% to 105.1% for rice false smut balls at spiking levels of 0.2 to 3.2 mg/g and from 92.6% to 103.5% for rice grains at spiking levels of 100 to 5000 ng/g. Comparison of ustiloxin B content in rice false smut balls and rice grains detected by both icELISA and high performance liquid chromatography (HPLC demonstrated that the developed icELISA can be employed as an effective and accurate method for the detection of ustiloxin B in rice false smut balls, as well as rice food and feed samples.

  18. Broad spectrum reactivity versus subtype specificity-trade-offs in serodiagnosis of influenza A virus infections by competitive ELISA.

    Science.gov (United States)

    Postel, A; Ziller, M; Rudolf, M; Letzel, T; Ehricht, Ralf; Pourquier, P; Dauber, M; Grund, C; Beer, Martin; Harder, T C

    2011-04-01

    Avian influenza viruses (AIVs) of the H5 and H7 subtypes can cause substantial economic losses in the poultry industry and are a potential threat to public health. Serosurveillance of poultry populations is an important monitoring tool and can also be used for control of vaccination campaigns. The purpose of this study was to develop broadly reactive, yet subtype-specific competitive ELISAs (cELISAs) for the specific detection of antibodies to the notifiable AIV subtypes H5 and H7 as an alternative to the gold standard haemagglutination inhibition assay (HI). Broadly reacting monoclonal competitor antibodies (mAbs) and genetically engineered subtype H5 or H7 haemagglutinin antigen, expressed and in vivo biotinylated in insect cells, were used to develop the cELISAs. Sera from galliform species and water fowl (n=793) were used to evaluate the performance characteristics of the cELISAs. For the H5 specific cELISA, 98.1% test sensitivity and 91.5% test specificity (97.7% and 90.2% for galliforms; 98.9% and 92.6% for waterfowl), and for the H7 cELISA 97.3% sensitivity and 91.8% specificity (95.3% and 98.9% for galliforms; 100% and 82.7% for waterfowl) were reached when compared to HI. The use of competitor mAbs with broad spectrum reactivity within an AIV haemagglutinin subtype allowed for homogenous detection with high sensitivity of subtype-specific antibodies induced by antigenically widely distinct isolates including antigenic drift variants. However, a trade-off regarding sensitivity versus nonspecific detection of interfering antibodies induced by phylo- and antigenically closely related subtypes, e.g., H5 versus H2 and H7 versus H15, must be considered. The observed intersubtype antibody cross-reactivity remains a disturbance variable in AIV subtype-specific serodiagnosis which negatively affects specificity. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Elisa for the diagnosis and epidemiology of Brucella abortus infection in cattle in Chile

    International Nuclear Information System (INIS)

    Rojas, X.; Alonso, O.

    1998-01-01

    A serum bank of 1251 adult cows sera was prepared. The sera originated from animals of three different epidemiological groups: 1) 244 from infected cows, strain 19 vaccinated when calves; 2) 507 from herds free of infection but all cows were strain 19 vaccinated when calves and 3) the last group, 500 sera from cows free of infection and non-vaccinated. All the sera where tested with the routine Rose Bengal (RB) Rivanol (RIV) and Complement Fixation (CF) tests and additionally three enzyme immunoassays were performed. They included two indirect Elisa both using the kit from the Joint FAO/IAEA Division, Vienna, Austria. One assay used a polyclonal conjugated antibody (I-ELISAp) and the other a monoclonal conjugated antibody (I-ELISAm). The third assay was a competitive ELISA (C-ELISA) performed with sLPS, plus monoclonal antibody, M84, and goat anti-mouse antibody-HRPO. Using the CFT as 'gold standard' the sensitivities of all the methods were: RB 87.1%, RIV 87.1%, I-ELISAp 100% I-ELISAm 100%. The calculated specificity was: RB 100%, RIV 100%, I-ELISAp 96.4% and I-ELISAm 100%. In the group of infected animals (244) the following results were obtained: RB 13.5%, RIV 11.9%, CF 12.7%, I-ELISAp 50.8% and I-ELISAm 22.9%. Results for the non-vaccinated group were: RB 0.2%, RIV 0%, CFT 0.2%, I-ELISAp 6.9% and I-ELISAm 2.9%. The C-ELISA was performed on samples from the positive group or with positivity values close to the cut-off value in the I-ELISAm. In the infected group 28 out of 63 animals were detected as infected and from the non-vaccinated herds none of 15 I-ELISAm positive samples were detected as infected in the C-ELISA. (author)

  20. Development and evaluation of an ELISA for human trefoil factor 3

    DEFF Research Database (Denmark)

    Vestergaard, Else Marie; Poulsen, Steen Seier; Grønbaek, Henning

    2002-01-01

    are warranted. METHODS: An ELISA was developed that uses two antibodies from rabbits immunized with recombinant human TFF3 and a calibrator (3-100 pmol/L) prepared from recombinant human TFF3. RESULTS: The ELISA had a detection limit of 3.0 pmol/L. The imprecision (CV) was 5-9% for mean concentrations of 13...... exacerbation of chronic inflammatory bowel disease restricted to the colon, normal concentrations and only minor variations during treatment and tapering were observed. CONCLUSIONS: The ELISA measures TFF3 in human serum and represents a specific and precise method for measurement of TFF3, which...

  1. Generation of Monoclonal Antibodies against Ag85A Antigen of Mycobacterium tuberculosis and Application in a Competitive ELISA for Serodiagnosis of Bovine Tuberculosis

    Directory of Open Access Journals (Sweden)

    Zhengzhong Xu

    2017-06-01

    Full Text Available The Ag85 complex functions as the main secretory protein of Mycobacterium tuberculosis (M. tuberculosis and BCG. This complex is composed of the proteins, Ag85A, Ag85B, and Ag85C, with Ag85A thought to play the largest role within the complex. However, the lack of commercially available monoclonal antibodies (mAbs against Ag85A still hinders the biological and applicative research on this protein. In this study, we developed and identified anti-Ag85A mAbs, and five hybridoma cells were established. Using the indirect immunofluorescence test, we found that two anti-Ag85A mAbs did not cross-react with Ag85B and/or Ag85C. In addition, we showed that all of the mAbs tested in this study are able to react with endogenous Ag85A protein in BCG and rBCG:Ag85A using indirect ELISA and Western blot analyses. A competitive ELISA (cELISA based on mAb 3B8 was developed, the analyses of clinic serum samples from cattle with bovine tuberculosis (TB and healthy cattle demonstrated that the sensitivity of the cELISA was 54.2% (26/48 and the specificity was 83.5% (167/200. This study demonstrated that the mAbs against Ag85A will provide useful reagents for further investigation into the function of the Ag85 complex and can be used for serodiagnosis of bovine TB.

  2. Physical and photophysical properties of mixed double- and triple-decker sandwiches of porphyrins and phthalocyanines

    International Nuclear Information System (INIS)

    Salabert, Isabelle

    1995-01-01

    The study of electron transfer and charge recombination processes in various oligomers of porphyrins and phthalocyanines is reported. Our objective is to determine the nature of processes which compete with electron transfer in such Systems. The first part of this thesis is devoted to the study of mixed double- and triple-decker sandwich compounds of porphyrins and phthalocyanines of cerium and praseodymium. The charge transfer reaction and geminated recombination from excited complexes in solution and in sublimated film are investigated by time-resolved absorption spectroscopy with femtosecond time scale resolution. These results show the influence of the magnetic nature of the metal ion and of the relative position of the chromophores in the complex on the photophysical processes. The physical and photophysical properties of complexes formed by pairing in solution porphyrins and porphyrazines bearing oppositely charged substituent are reported in the second part. The formation of mixed aggregates of high order (2 to 5) is observed and their nature are spectrally characterized. The photoproducts issued from these complexes are extremely stable. (author) [fr

  3. Self-healing sandwich structures incorporating an interfacial layer with vascular network

    International Nuclear Information System (INIS)

    Chen, Chunlin; Peters, Kara; Li, Yulong

    2013-01-01

    A self-healing capability specifically targeted for sandwich composite laminates based on interfacial layers with built-in vascular networks is presented. The self-healing occurs at the facesheet–core interface through an additional interfacial layer to seal facesheet cracks and rebond facesheet–core regions. The efficacy of introducing the self-healing system at the facesheet–core interface is evaluated through four-point bend and edgewise compression testing of representative foam core sandwich composite specimens with impact induced damage. The self-healing interfacial layer partially restored the specific initial stiffness, doubling the residual initial stiffness as compared to the control specimen after the impact event. The restoration of the ultimate specific skin strength was less successful. The results also highlight the critical challenge in self-healing of sandwich composites, which is to rebond facesheets which have separated from the core material. (paper)

  4. Quantitative Detection of Horse Contamination in Cooked Meat Products by ELISA.

    Science.gov (United States)

    Thienes, Cortlandt P; Masiri, Jongkit; Benoit, Lora A; Barrios-Lopez, Brianda; Samuel, Santosh A; Cox, David P; Dobritsa, Anatoly P; Nadala, Cesar; Samadpour, Mansour

    2018-05-01

    Concerns about the contamination of meat products with horse meat and new regulations for the declaration of meat adulterants have highlighted the need for a rapid test to detect horse meat adulteration. To address this need, Microbiologique, Inc., has developed a sandwich ELISA that can quantify the presence of horse meat down to 0.1% (w/w) in cooked pork, beef, chicken, goat, and lamb meats. This horse meat authentication ELISA has an analytical sensitivity of 0.000030 and 0.000046% (w/v) for cooked and autoclaved horse meat, respectively, and an analytical range of quantitation of 0.05-0.8% (w/v) in the absence of other meats. The assay is rapid and can be completed in 1 h and 10 min. Moreover, the assay is specific for cooked horse meat and does not demonstrate any cross-reactivity with xenogeneic cooked meat sources.

  5. Characterization of immune response to killed leishmania major promastigotes plus BCG vaccine in Sudanese volunteers: a double-blind placebo controlled study

    International Nuclear Information System (INIS)

    Sati, Iman Nasr Eldin

    1996-12-01

    This work was examined whether intradermal immunization of healthy adult Sudanese volunteers with killed leishmania major (KLM) promastigotes plus BCG would induce antigen-specific T cell responses. Only healthy Sudanese volunteers with negative reactivity to leishmania skin test and with ≤20 mm induration of reactivity to purified protein derivative (PPD) were included in the trial. Group (A) (n=3): received a single dose (0.1ml) at a concentration of 10 mg protein of a whole cell component of KLM promastigotes/ml BCG, group (B) (n=12): received as a single dose of viable attenuated BCG alone (0.1 ml) at a concentration of 1 mg protein/ml diluent, group (C) (n=11): received the vaccine diluent only (Placebo) (o.1 ml). Study subjects were tested for their immunological and clinical responses before intervention, . Following vaccination 65% of group (A) subjects converted in their reactivity to leishmanin skin testing,non of the BCG vaccinated subjects converted in leishmanin skin test and only one subject of group (C) became leishmanin positive. Levels of Interferon-gamma (IFN-γ), interleukin-5 (IL-5) and interleukin-10 (IL-10) were measured by a double sandwich enzyme-linked immunosorbent assay (ELISA). A vaccine was considered as a positive responder in terms of cytokine production when the level of the produced cytokine was equal to the 80th percentile of the levels produced by the volunteers in the placebo group. 92% of the group vaccinated with KLM=BCG had circulating T cells. No significant of IL-5 or Il-10 was reported in any of the volunteers in the three group. Levels of anti l eishmania specific IgG were measured by ELISA in optical densities. Volunteers with mean antibody titre above the cut-off point (mean=3X standard deviation) were considered to have positive scores. Accordingly after vaccination 7.69% one volunteers in group (A) had a positive antibody response corresponding to 0% in the other two groups. No serious side effects were reported

  6. Opportunities and challenges when pooling milk samples using ELISA

    DEFF Research Database (Denmark)

    Græsbøll, Kaare; Andresen, Lars Ole; Hisham Beshara Halasa, Tariq

    2017-01-01

    -positive samples by pooling. To illustrate this, the sensitivity of antibody ELISA on pooled samples of bovine milk for Salmonella Dublin, Mycobacterium avium spp. paratuberculosis, and bovine virus diarrhea was tested. For these milk assays, the analytical sensitivity decreased rapidly with increasing pool sizes...

  7. Improved quantification of a commercial enzyme-linked immunosorbent assay kit for measuring anti-MDA5 antibody.

    Science.gov (United States)

    Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka

    2018-04-09

    To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.

  8. TOXOCARIASIS: SEROLOGICAL DIAGNOSIS BY INDIRECT ANTIBODY COMPETITION ELISA Diagnóstico sorológico da toxocaríase através do método de ELISA indireto de competição

    Directory of Open Access Journals (Sweden)

    Cáris Maroni NUNES

    1999-03-01

    Full Text Available Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%.A toxocaríase, uma emergente zoonose, é uma síndrome clínica decorrente da infecção humana por larvas de Toxocara canis e Toxocara cati, parasitas intestinais de cães e gatos, respectivamente. A dificuldade de detecção das larvas nos tecidos e a inespecificidade dos sinais clínicos tornam os testes sorológicos os meios diagnósticos mais adequados. Os antígenos excretores-secretores de T. canis empregados nos testes sorológicos, embora tenham contribuído para melhorar a especificidade destes, apresentam reações cruzadas com diversos parasitas

  9. Development and evaluation of porcine cysticercosis QuickELISA in Triturus EIA analyzer.

    Science.gov (United States)

    Handali, Sukwan; Pattabhi, Sowmya; Lee, Yeuk-Mui; Silva-Ibanez, Maria; Kovalenko, Victor A; Levin, Andrew E; Gonzalez, Armando E; Roberts, Jacquelin M; Garcia, Hector H; Gilman, Robert H; Hancock, Kathy; Tsang, Victor C W

    2010-01-01

    We evaluated three diagnostic antigens (recombinant GP50, recombinant T24H, and synthetic Ts18var1) for cysticercosis and found that all three performed well in detecting cysticercosis in humans and pigs in several assay formats. These antigens were adapted to a new antibody detection format (QuickELISA). With one single incubation step which involves all reactants except the enzyme substrate, the QuickELISA is particularly suited for automation. We formatted the QuickELISA for the Triturus EIA analyzer for testing large numbers of samples. We found that in QuickELISA formats rGP50 and rT24H have better sensitivity and specificity than sTs18var1 for detecting porcine cysticercosis.

  10. Polyclonal antibodies for the detection of Trypanosoma cruzi circulating antigens.

    Directory of Open Access Journals (Sweden)

    Edith S Málaga-Machaca

    2017-11-01

    Full Text Available Detection of Trypanosoma cruzi antigens in clinical samples is considered an important diagnostic tool for Chagas disease. The production and use of polyclonal antibodies may contribute to an increase in the sensitivity of immunodiagnosis of Chagas disease.Polyclonal antibodies were raised in alpacas, rabbits, and hens immunized with trypomastigote excreted-secreted antigen, membrane proteins, trypomastigote lysate antigen and recombinant 1F8 to produce polyclonal antibodies. Western blot analysis was performed to determine specificity of the developed antibodies. An antigen capture ELISA of circulating antigens in serum, plasma and urine samples was developed using IgY polyclonal antibodies against T. cruzi membrane antigens (capture antibody and IgG from alpaca raised against TESA. A total of 33 serum, 23 plasma and 9 urine samples were analyzed using the developed test. Among serum samples, compared to serology, the antigen capture ELISA tested positive in 55% of samples. All plasma samples from serology positive subjects were positive in the antigen capture ELISA. All urine positive samples had corresponding plasma samples that were also positive when tested by the antigen capture ELISA.Polyclonal antibodies are useful for detection of circulating antigens in both the plasma and urine of infected individuals. Detection of antigens is direct evidence of the presence of the parasite, and could be a better surrogate of current infection status.

  11. Surface modification of polyacrylonitrile fiber for immobilization of antibodies and detection of analyte

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Swati, E-mail: swatijain.iitd@gmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Chattopadhyay, Sruti, E-mail: srutic@hotmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Jackeray, Richa, E-mail: richajackeray.iitd@gmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Singh, Harpal, E-mail: harpal2000@yahoo.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India)

    2009-11-10

    Pendent nitrile groups of multifilamentous polyacrylonitrile (PAN) fibers were reduced to amino groups using lithium aluminum hydride for different time of reduction and amine content was estimated by performing acid-base titrations. Attenuated total reflection-fourier transform infrared spectroscopy (ATR-FTIR) and Differential Scanning Calorimetry (DSC) were used for the characterization of the generated amino groups and thermal properties of the reduced fibers, respectively. The surface morphology of the fibers after reduction and immobilization was characterized using Scanning Electron Microscope (SEM). The newly formed amino groups of the fibers were activated by using glutaraldehyde for the covalent linking of Goat anti-Rabbit IgG-HRP (GAR-HRP) antibody enzyme conjugate. Modified PAN fibers were evaluated as a matrix for sandwich ELISA by using Goat anti-Rabbit antibody (GAR-IgG), Rabbit anti-Goat (RAG-IgG) as analyte and enzyme conjugate GAR-HRP. The fibers reduced for 24 h were able to detect the analyte RAG-IgG at a concentration as low as 3.75 ng mL{sup -1} with 12% skimmed milk as blocking reagent for the optimized concentration of primary antibody GAR-IgG 3 {mu}g mL{sup -1} and peroxidase conjugate GAR-HRP dilution of 8000 fold. The sensitivity, specificity and reproducibility of the developed immunoassay was further established with antibodies present in human blood using Rabbit anti-Human (RAH-IgG) antibody and the corresponding HRP enzyme conjugate. As low as 0.1 {mu}L of human blood was sufficient to perform the assay with the modified fibers.

  12. Evaluation of cysticercus-specific IgG (total and subclasses and IgE antibody responses in cerebrospinal fluid samples from patients with neurocysticercosis showing intrathecal production of specific IgG antibodies

    Directory of Open Access Journals (Sweden)

    Lisandra Akemi Suzuki

    Full Text Available In the present study, an enzyme-linked immunosorbent assay (ELISA standardized with vesicular fluid of Taenia solium cysticerci was used to screen for IgG (total and subclasses and IgE antibodies in cerebrospinal fluid (CSF samples from patients with neurocysticercosis showing intrathecal production of specific IgG antibodies and patients with other neurological disorders. The following results were obtained: IgG-ELISA: 100% sensitivity (median of the ELISA absorbances (MEA=1.17 and 100% specificity; IgG1-ELISA: 72.7% sensitivity (MEA=0.49 and 100% specificity; IgG2-ELISA: 81.8% sensitivity (MEA=0.46 and 100% specificity; IgG3-ELISA: 63.6% sensitivity (MEA=0.12 and 100% specificity; IgG4-ELISA: 90.9% sensitivity (MEA=0.85 and 100% specificity; IgE-ELISA 93.8% sensitivity (MEA=0.60 and 100% specificity. There were no significant differences between the sensitivities and specificities in the detection of IgG-ELISA and IgE-ELISA, although in CSF samples from patients with neurocysticercosis the MEA of the IgG-ELISA was significantly higher than that of the IgE-ELISA. The sensitivity and MEA values of the IgG4-ELISA were higher than the corresponding values for the other IgG subclasses. Future studies should address the contribution of IgG4 and IgE antibodies to the physiopathology of neurocysticercosis.

  13. Elevated Subclinical Double-Stranded DNA Antibodies and Future Proliferative Lupus Nephritis

    Science.gov (United States)

    Lee, Jessica J.; Prince, Lisa K.; Baker, Thomas P.; Papadopoulos, Patricia; Edison, Jess; Abbott, Kevin C.

    2013-01-01

    Summary Background and objectives Elevated anti–double-stranded DNA (dsDNA) antibody and C-reactive protein are associated with proliferative lupus nephritis (PLN). Progression of quantitative anti-dsDNA antibody in patients with PLN has not been compared with that in patients with systemic lupus erythematosus (SLE) without LN before diagnosis. The temporal relationship between anti-dsDNA antibody and C-reactive protein elevation has also not been evaluated. Design, setting, participants, & measurements This case-control Department of Defense Serum Repository (established in 1985) study compared longitudinal prediagnostic quantitative anti-dsDNA antibody and C-reactive protein levels in 23 patients with biopsy-proven PLN (Walter Reed Army Medical Center, 1993–2009) with levels in 21 controls with SLE but without LN matched for patient age, sex, race, and age of serum sample. The oldest (median, 2601 days; 25%, 1245 days, 75%, 3075 days), the second to last (368; 212, 635 days), and the last (180; 135, 477 days) serum sample before diagnosis were analyzed. Results More patients with PLN had an elevated anti-dsDNA antibody level than did the matched controls at any point (78% versus 5%; P4 years (33% versus 0%; P=0.04) before diagnosis. A rate of increase >1 IU/ml per year (70% versus 0%; P<0.001) was most specific for PLN. The anti-dsDNA antibody levels increased before C-reactive protein did in most patients with an antecedent elevation (92% versus 8%; P<0.001). Conclusions Elevated anti-dsDNA antibody usually precedes both clinical and subclinical evidence of proliferative LN, which suggests direct pathogenicity. Absolute anti-dsDNA antibody level and rate of increase could better establish risk of future PLN in patients with SLE. PMID:23833315

  14. An ultrasensitive sandwich-type electrochemical immunosensor based on the signal amplification system of double-deck gold film and thionine unite with platinum nanowire inlaid globular SBA-15 microsphere.

    Science.gov (United States)

    Wang, Ping; Li, Mingdang; Pei, Fubin; Li, Yueyun; Liu, Qing; Dong, Yunhui; Chu, Qingyan; Zhu, Hongjun

    2017-05-15

    A novel thionine unites with platinum nanowire inlaid globular SBA-15 (Pt NWs@g-SBA-15/Thi) not only utilizes as an efficient electrical signal probe but also constitutes an amplifying system with double-deck gold film (D-Au film) have been applied to the fabrication of sandwich-type immunosensor for detecting hepatitis B surface antigen (HBs Ag). The D-Au film can accelerate the electron transfer on the electrode interface due to the tunneling effect between the two Au films and can improve the load capacity of primary antibodies (Ab 1 ) because of the good biocompatibility. The Pt NWs@g-SBA-15/Thi with uniform globular morphology not only can effectively reduce the spatial limitation for loading the secondary antibodies (Ab 2 ) but also can provide outstanding pore accessibility of guest species from outside and offer catalytically active sites in a large scale. Besides, the presence of Thi can well enhance the electrical conductivity of Pt NWs@g-SBA-15/Thi. With the good cooperation between D-Au film and Pt NWs@g-SBA-15/Thi, a linear relationship between current signals and the concentrations of HBs Ag was obtained in the wide range from 10 fg/mL to 100ng/mL and the detection limit of HBs Ag was 3.3 fg/mL (signal-to-noise ratio of 3). Furthermore, the designed immunosensor with excellent selectivity, reproducibility and stability shows excellent performance in detection of human serum samples and provides a promising capacity for detecting a wide range of other tumor markers in clinical application. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Development of enzyme linked immunosorbent assay (ELISA) for the detection of root-knot nematode Meloidogyne incognita.

    Science.gov (United States)

    Kapur-Ghai, J; Kaur, M; Goel, P

    2014-09-01

    Root-knot nematodes (Meloidogyne incognita) are obligate, sedentary plant endoparasites that are extremely polyphagous in nature and cause severe economic losses in agriculture. Hence, it is essential to control the parasite at an early stage. For any control strategy to be effective, an early and accurate diagnosis is of paramount importance. Immunoassays have the inherent advantages of sensitivity and specificity; have the potential to identify and quantify these plant-parasitic nematodes. Hence, in the present studies, enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of M.incognita antigens. First an indirect ELISA was developed for detection and titration of anti-M.incognita antibodies. Results indicated as high as 320 K titre of the antisera. Finally competitive inhibition ELISA was developed employing these anti-M.incognita antibodies for detection of M.incognita antigens. Sensitivity of ELISA was 10 fg. Competitive inhibition ELISA developed in the present studies has the potential of being used as an easy, rapid, specific and sensitive diagnostic tool for the detection of M.incognita infection.

  16. Infeksi Cucumber mosaic virus dan Chilli veinal mottle virus pada Cabai di Kabupaten Rejang Lebong, Bengkulu

    Directory of Open Access Journals (Sweden)

    Mimi Sutrawati

    2013-04-01

    Full Text Available Mosaic disease caused by Cucumber mosaic virus (CMV and Chilli veinal mottle Virus (ChiVMV has been distributed widely in chilli in Indonesia and considered as important disease. A research was conducted to investigate the spread and incidence of CMV and ChiVMV in Rejang Lebong, Bengkulu and to identify its insect vector. Symptomatic and asymptomatic leaf samples were collected systematically from several chillipepper fields for further detection by DAS-ELISA (Double antibody sandwich-enzyme linked immunosorbant assay using specific antibody for CMV and ChiVMV. The result showed that infection of both CMV and ChiVMV was found with disease incidence reached 20-50%, whereas infection only by ChiVMV or CMV were 50-80% and 20-50%, respectively. One species of aphid, i.e. Aphis gossypii was found from the fields.Key words: Aphis gossypii, CMV, ChiVMV, disease incidence

  17. Development of hen antihepatitis B antigen IgY-based conjugate for ELISA assay

    Directory of Open Access Journals (Sweden)

    Najat Muayed Nafea

    2015-01-01

    Conclusions: This study showed that laying hens can be used as an alternative source for production of polyclonal antibodies against HBsAg and anti-HBs IgY could be labeled with HRP enzyme and could subsequently be used successfully as secondary antibody in ELISA for detection of HBsAg in the patients sera.

  18. An Evaluation Study of Enzyme-Linked Immunosorbent Assay (ELISA) Using Recombinant Protein Pap31 for Detection of Antibody against Bartonella bacilliformis Infection among the Peruvian Population

    Science.gov (United States)

    Angkasekwinai, Nasikarn; Atkins, Erin H.; Romero, Sofia; Grieco, John; Chao, Chien Chung; Ching, Wei Mei

    2014-01-01

    Reliable laboratory testing is of great importance to detect Bartonella bacilliformis infection. We evaluated the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) using recombinant protein Pap31 (rPap31) for the detection of antibodies against B. bacilliformis as compared with immunofluorescent assay (IFA). Of the 302 sera collected between 1997 and 2000 among an at-risk Peruvian population, 103 and 34 samples tested positive for IFA-immunoglobulin G (IgG) and IFA-IgM, respectively. By using Youden's index, the cutoff values of ELISA-IgG at 0.915 gave a sensitivity of 84.5% and specificity of 94%. The cutoff values of ELISA-IgM at 0.634 gave a sensitivity of 88.2% and specificity of 85.1%. Using latent class analysis, estimates of sensitivity and specificity of almost all the assays were slightly higher than those of a conventional method of calculation. The test is proved beneficial for discriminating between infected and non-infected individuals with the advantage of low-cost and high-throughput capability. PMID:24515944

  19. [Construction of human phage antibody library and screening for human monoclonal antibodies of amylin].

    Science.gov (United States)

    Gong, Qian; Li, Chang-ying; Chang, Ji-wu; Zhu, Tie-hong

    2012-06-01

    To screen monoclonal antibodies to amylin from a constructed human phage antibody library and identify their antigenic specificity and combining activities. The heavy chain Fd fragment and light chain of human immunoglobulin genes were amplified from peripheral blood lymphocytes of healthy donors using RT-PCR, and then inserted into phagemid pComb3XSS to generate a human phage antibody library. The insertion of light chain or heavy chain Fd genes were identified by PCR after the digestion of Sac I, Xba I, Xho Iand Spe I. One of positive clones was analyzed by DNA sequencing. The specific anti-amylin clones were screened from antibody library against human amylin antigens and then the positive clones were determined by Phage-ELISA analysis. A Fab phage antibody library with 0.8×10(8); members was constructed with the efficacy of about 70%. DNA sequence analysis indicated V(H); gene belonged to V(H);3 gene family and V(λ); gene belonged to the V(λ); gene family. Using human amylin as panning antigen, specific anti-amylin Fab antibodies were enriched by screening the library for three times. Phage-ELISA assay showed the positive clones had very good specificity to amylin antigen. The successful construction of a phage antibody library and the identification of anti-amylin Fab antibodies provide a basis for further study and preparation of human anti-amylin antibodies.

  20. Antiviral activity of tenofovir against Cauliflower mosaic virus and its metabolism in Brassica pekinensis plants.

    Science.gov (United States)

    Spak, Josef; Votruba, Ivan; Pavingerová, Daniela; Holý, Antonín; Spaková, Vlastimila; Petrzik, Karel

    2011-11-01

    The antiviral effect of the acyclic nucleoside phosphonate tenofovir (R)-PMPA on double-stranded DNA Cauliflower mosaic virus (CaMV) in Brassica pekinensis plants grown in vitro on liquid medium was evaluated. Double antibody sandwich ELISA and PCR were used for relative quantification of viral protein and detecting nucleic acid in plants. (R)-PMPA at concentrations of 25 and 50 mg/l significantly reduced CaMV titers in plants within 6-9 weeks to levels detectable neither by ELISA nor by PCR. Virus-free plants were obtained after 3-month cultivation of meristem tips on semisolid medium containing 50 mg/l (R)-PMPA and their regeneration to whole plants in the greenhouse. Studying the metabolism of (R)-PMPA in B. pekinensis revealed that mono- and diphosphate, structural analogs of NDP and/or NTP, are the only metabolites formed. The data indicate very low substrate activity of the enzymes toward (R)-PMPA as substrate. The extent of phosphorylation in the plant's leaves represents only 4.5% of applied labeled (R)-PMPA. In roots, we detected no radioactive peaks of phosphorylated metabolites of (R)-PMPAp or (R)-PMPApp. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Elisa-Like Format for Comparing DNA Capture Elements (Aptamers) to Antibody in Diagnostic Efficacy

    National Research Council Canada - National Science Library

    Kiel, Johnathan L; Holwitt, Eric A; Vivekananda, Jeevalatha; Franz, Veronica

    2004-01-01

    .... For this purpose, the microtiter, heterologous phase, ELISAlike sandwich assay test was chosen. The antigen of choice was the standard antigen used in commercially available agglutination tests for Francisella tularensis (tularemia bacterium...

  2. Diagnosis of Herpes Simplex Encephalitis by ELISA Using Antipeptide Antibodies Against Type-Common Epitopes of Glycoprotein B of Herpes Simplex Viruses.

    Science.gov (United States)

    Bhullar, Shradha S; Chandak, Nitin H; Baheti, Neeraj N; Purohit, Hemant J; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S

    2016-01-01

    Herpes simplex encephalitis (HSE) represents one of the most severe infectious diseases of the central nervous system (CNS). As effective antiviral drugs are available, an early, rapid, and reliable diagnosis has become important. The objective of this article was to develop a sensitive ELISA protocol for herpes simplex viruses (HSV) antigen detection and quantitation by assessing the usefulness of antipeptide antibodies against potential peptides of HSV glycoprotein B (gB). A total of 180 cerebrospinal fluid (CSF) samples of HSE and non-HSE patients were analyzed using a panel of antipeptide antibodies against synthetic peptides of HSV glycoprotein gB. The cases of confirmed and suspected HSE showed 80% and 51% positivity for antipeptide against synthetic peptide QLHDLRF and 77% and 53% positivity for antipeptide against synthetic peptide MKALYPLTT, respectively for the detection of HSV antigen in CSF. The concentration of HSV antigen was found to be higher in confirmed HSE as compared to suspected HSE group and the viral load correlated well with antigen concentration obtained using the two antipeptides in CSF of confirmed HSE group. This is the first article describing the use of antibodies obtained against synthetic peptides derived from HSV in diagnostics of HSE using patients' CSF samples.

  3. Application of serum anticardiolipin antibody (ACA) determination with ELISA for detection of intra-uterine growth retardation (IUGR)

    International Nuclear Information System (INIS)

    Chen Wen; Zhong Jianhui; Shen Junnan

    2005-01-01

    Objective: To explore the interrelationship between presence of serum ACA and development of IUGR. Methods: Serum ACA contents were examined with ELISA in 5330 apparently normal pregnant women. The placentae in 16 pregnancies with IUGR and positive ACA were examined with immunofluorescence microscopy. Results: Among the 5330 pregnant women there were 144 with positive ACA (2.70%), in whom there were 22 IUGR cases (22/144, 15.28% ). The rate of IUGR in the remaining ACA negative women was only 1.77% (92/5186), the difference being very significant (P<0.01 ). ACA IgG was positive in 5 of the IUGR neonates, All the placental tissues examined with immunofluorescence microscopy showed positive immunoglobulin fluorescence antibody and complement discoloration. Conclusion: Positive ACA is one of the causative factors of development of IUGR and determination of ACA in pregnant women was helpful for early detection of IUGR. (authors)

  4. [Diagnosis for human parvovirus B19-polyarthritis: usefulness of empty particle B19.ELISA and B19-DNA.PCR].

    Science.gov (United States)

    Hatakeyama, Y; Ishii, K; Murai, C; Sugamura, K; Mitomo, N; Saitoh, T; Rikimaru, Y; Okazaki, T; Sasaki, T

    1998-10-01

    To evaluate the usefulness of new ELISA for human parvovirus B19 (B19) antibodies and PCR for the diagnosis of acute onset of B19 polyarthritis. We evaluated the reproducibility and sensitivity on the detection of anti-B19 antibody by ELISA using recombinant VP-1 and VP-2 (empty particle), and then studied for the prevalence of IgM and IgG B19 antibody in 125 samples for anti-B19 tests. The random study on anti-B19 antibody assay as well as PCR for B19-DNA was also performed in 130 cases with acute onset of arthritis excluding those with known origins, 224 with rheumatoid arthritis and 149 with other categories. The results by using B19-empty particle ELISA were reproducible and showed the assay was a sensitive way for clinical use. IgM anti-B19 antibodies were positive not only in all samples from erythema infectiosum, but also often in those from hemolytic anemia, pure red cell aplasia, fetal hydrops, hepatic injury, fever of unknown origin. Among 130 with acute onset of arthritis, 21 showed positive tests for IgM anti-B19 antibody and/or B19 DNA. On the other hand, 4 among 224 patients with rheumatoid arthritis were positive for IgM anti-B19 antibody, but all of 149 in control group were negative for IgM anti-B19 antibodies and for B19 DNA. Anti-B19 ELISA using B19-empty particle which has been introduced as a routine test system, is a useful tool for the diagnosis of acute onset of B19 arthritis. An additional examination using PCR for B19 DNA may contribute for understanding persistent B19 polyarthritis or reactivation of B19 infection.

  5. An efficient method for isolating antibody fragments against small peptides by antibody phage display

    DEFF Research Database (Denmark)

    Duan, Zhi; Siegumfeldt, Henrik

    2010-01-01

    We generated monoclonal scFv (single chain variable fragment) antibodies from an antibody phage display library towards three small synthetic peptides derived from the sequence of s1-casein. Key difficulties for selection of scFv-phages against small peptides were addressed. Small peptides do....... The scFvs were sequenced and characterized, and specificity was characterized by ELISA. The methods developed in this study are universally applicable for antibody phage display to efficiently produce antibody fragments against small peptides....

  6. Modal analysis and acoustic transmission through offset-core honeycomb sandwich panels

    Science.gov (United States)

    Mathias, Adam Dustin

    The work presented in this thesis is motivated by an earlier research that showed that double, offset-core honeycomb sandwich panels increased thermal resistance and, hence, decreased heat transfer through the panels. This result lead to the hypothesis that these panels could be used for acoustic insulation. Using commercial finite element modeling software, COMSOL Multiphysics, the acoustical properties, specifically the transmission loss across a variety of offset-core honeycomb sandwich panels, is studied for the case of a plane acoustic wave impacting the panel at normal incidence. The transmission loss results are compared with those of single-core honeycomb panels with the same cell sizes. The fundamental frequencies of the panels are also computed in an attempt to better understand the vibrational modes of these particular sandwich-structured panels. To ensure that the finite element analysis software is adequate for the task at hand, two relevant benchmark problems are solved and compared with theory. Results from these benchmark results compared well to those obtained from theory. Transmission loss results from the offset-core honeycomb sandwich panels show increased transmission loss, especially for large cell honeycombs when compared to single-core honeycomb panels.

  7. Development of enzyme-linked immunosorbent assay (ELISA) for glutathione S-transferase (GST-S) protein in the intertidal copepod Tigriopus japonicus and its application for environmental monitoring.

    Science.gov (United States)

    Rhee, Jae-Sung; Kim, Bo-Mi; Jeong, Chang-Bum; Leung, Kenneth Mei Yee; Park, Gyung Soo; Lee, Jae-Seong

    2013-11-01

    To utilize the GST-S protein as a useful biomarker for environmental contamination, we developed a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA) in the intertidal copepod Tigriopus japonicus. Two polyclonal antibodies, TJ-GST-S1 and TJ-GST-S2, were raised against two TJ-GST-S synthetic peptides. Also a recombinant TJ-GST-S protein was purified as a standard for ELISA development. Each polyclonal antibody was tested by Western blot analysis and indirect ELISA. Of two polyclonal antibodies, TJ-GST-S2 ELISA was further employed due to its wide range of detection and the limit of specificity compared to those of TJ-GST-S1 ELISA system. After exposure to 4 metals (Ag, As, Cd, and Cu) to T. japonicus, the amount of TJ-GST-S protein was significantly elevated in a concentration-dependent manner. Also, TJ-GST-S protein was upregulated at relative high concentrations of B[α]P, PCB, and TBT. In this paper, we suggest that T. japonicas ELISA for TJ-GST-S2 is useful as a potential indicator system for marine contaminants. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Rapid Immuno-Chromatographic Assay for the Detection of Antibodies to HIV Compare with Elisa among Voluntary and Replacement Blood Donor of Mymensingh Medical College Hospital.

    Science.gov (United States)

    Chakrabarty, P; Rudra, S; Hossain, M A; Begum, S A; Mirza, T T; Rudra, M

    2015-04-01

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from voluntary and replacement blood donors & HIV-infected patients (positive samples from BSMMU, Dhaka). Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd.), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Biotech) were evaluated between 1st February to 30th June, 2013 using 400 whole blood samples from voluntary and replacement blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Only 01 sample including ten positive samples from BSMMU were confirmed HIV-1 antibody positive, while 399 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9) respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive

  9. Assessment of the relative sensitivity of milk ELISA for detection of Mycobacterium avium ssp. paratuberculosis infectious dairy cows.

    Science.gov (United States)

    Laurin, Emilie L; Sanchez, Javier; Chaffer, Marcelo; McKenna, Shawn L B; Keefe, Greg P

    2017-01-01

    Milk ELISA are commonly used for detection of Mycobacterium avium ssp. paratuberculosis (MAP) antibodies in dairy cows, due to low cost and quick processing for large numbers of samples. However, low sensitivity and variations from host and environmental factors can impede detection of MAP antibodies at early disease stages. The objectives of our study were to assess the sensitivity of milk ELISA in comparison with fecal tests and to evaluate how detectable antibody concentrations in milk vary with changes in fecal shedding of MAP, cow age, cow parity, days in milk, and time of year. To compare the sensitivity of a commercial milk ELISA with solid and broth fecal culture and with fecal real-time PCR, a longitudinal study was performed for the identification of MAP-infectious animals as determined by prior fecal testing for MAP shedding. In addition, associations between variation in milk MAP ELISA score and changes in fecal MAP shedding, host age, days in milk, and season were evaluated. Monthly milk and fecal samples were collected over 1 yr from 46 cows that were previously shedding MAP in their feces. Sensitivity of milk ELISA was 29.9% (95% CI: 24.8 to 35.1%), compared with 46.7% (40.7 to 52.7%) for fecal solid culture, 55.0% (49.3 to 60.7%) for fecal broth culture, and 78.4% (73.3 to 83.1%) for fecal direct real-time PCR. The effect of stage of lactation could not be separated from the effect of season, with increased milk ELISA scores at greater days in milk in winter. However, unpredictable monthly variations in results were observed among the 3 assays for individual cow testing, which highlights the importance of identifying patterns in pathogen and antibody detection over time in MAP-positive herds. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of antibody responses in american visceral leishmaniasis by ELISA and immunoblot Avaliação da resposta imune humoral na leishmaniose visceral americana pelos métodos ELISA e "immunoblot"

    Directory of Open Access Journals (Sweden)

    Thomas G. Evans

    1989-06-01

    Full Text Available American visceral leishmaniasis (AVL is an important disease among children of northeast Brazil. In order to characterize antibody responses during AVL, sera of hospitalized patients were analyzed by ELISA and Western blot using a Leishmania chagasi antigen preparation. The ELISA was positive (asorbance [greater than or equals to] 0.196 at a serum dilution of 1:1024 in all patients at presentation, and fell to ward control levels over the following year. Only one of 72 control subjects tested positive, and that donor had a sibling with AVL. Immunoblots of the patients' sera recognized multiple bands, the most frequent of which were at approximately 116 kDa, 70 kDa, and 26 kDa. Less frenquently observed were bands at approximately 93 kDa, 74 kDa, 62 kDa, 46 kDa and 32 kDa. The ELISA responses and patterns of banding were distinctive for AVL, and could be used to differentiate patients with AVL from those with Chagas' disease of cutaneous leishmaniasis. Sera from six AVL patients followed for up to six weeks after treatment identified no new bands. Sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE of surface iodinated parasite proteins showed one major band and four minor bands, whereas SDS-PAGE of biotinylated prarasite proteins revealed a banding pattern similar to those of patient sera. AVL appears to produce characteristic immunoblot patterns which can be used along with a sensitive screening ELISA to diagnose AVL.A leishmaniose visceral americana é uma doença importante entre crianças do nordeste do Brasil. Com o objetivo de caracterizar a resposta imune humoral durante o curso da doença, foram analisados soros de pacientes hospitalizados, pelos métodos ELISA e Western blot, usando-se preparaçöes de antígenos de Leishmania donovani chagasi. O teste de ELISA foi positivo (absorbância > 0,196, numa diluiçäo de 1: 1024, em todos os pacientes no início da doença, diminuindo no decorrer do ano, para os níveis dos

  11. A monoclonal antibody to pestviruses in bovine and ovine sera

    International Nuclear Information System (INIS)

    Mweene, A.S.

    1991-01-01

    An enzyme-linked immunoabsorbent assay (ELISA) has been developed to defeat antibodies to pestviruses in bovine and ovine sera. Single sera from 211 cattle and 22 sheep from 7 different farms were tested using ELISA and Serum Neutralisation Test (SNT). 17 Monoclonal antibodies (Mabs) directed against P80, gp48 and gp53 were tested for ability to coat ELISA plates and capture the bovine viral diarrhea antigen. 5 mabs(WB 103, WB, 105, WB 112 against P80 kDa protein, WB 210 and WB 214 directed against gp48 and gp 53 kDa protein. Specific antibody to BVDV was detected by rabbit anti-bovine and anti-ovine IgG antisera. The quantitative correlation between two tests was good

  12. Widely Used Commercial ELISA Does Not Detect Precursor of Haptoglobin2, but Recognizes Properdin as a Potential Second Member of the Zonulin Family

    Directory of Open Access Journals (Sweden)

    Lucas Scheffler

    2018-02-01

    Full Text Available BackgroundThere is increasing evidence for the role of impaired intestinal permeability in obesity and associated metabolic diseases. Zonulin is an established serum marker for intestinal permeability and identical to pre-haptoglobin2. Here, we aimed to investigate the relationship between circulating zonulin and metabolic traits related to obesity.MethodsSerum zonulin was measured by using a widely used commercial ELISA kit in 376 subjects from the metabolically well-characterized cohort of Sorbs from Germany. In addition, haptoglobin genotype was determined in DNA samples from all study subjects.ResultsAs zonulin concentrations did not correlate to the haptoglobin genotypes, we investigated the specificity of the zonulin ELISA assay using antibody capture experiments, mass spectrometry, and Western blot analysis. Using serum samples that gave the highest or lowest ELISA signals, we detected several proteins that are likely to be captured by the antibody in the present kit. However, none of these proteins corresponds to pre-haptoglobin2. We used increasing concentrations of recombinant pre-haptoglobin2 and complement C3 as one of the representative captured proteins and the ELISA kit did not detect either. Western blot analysis using both the polyclonal antibodies used in this kit and monoclonal antibodies rose against zonulin showed a similar protein recognition pattern but with different intensity of detection. The protein(s measured using the ELISA kit was (were significantly increased in patients with diabetes and obesity and correlated strongly with markers of the lipid and glucose metabolism. Combining mass spectrometry and Western blot analysis using the polyclonal antibodies used in the ELISA kit, we identified properdin as another member of the zonulin family.ConclusionOur study suggests that the zonulin ELISA does not recognize pre-haptoglobin2, rather structural (and possibly functional analog proteins belonging to the mannose

  13. Widely Used Commercial ELISA Does Not Detect Precursor of Haptoglobin2, but Recognizes Properdin as a Potential Second Member of the Zonulin Family.

    Science.gov (United States)

    Scheffler, Lucas; Crane, Alyce; Heyne, Henrike; Tönjes, Anke; Schleinitz, Dorit; Ihling, Christian H; Stumvoll, Michael; Freire, Rachel; Fiorentino, Maria; Fasano, Alessio; Kovacs, Peter; Heiker, John T

    2018-01-01

    There is increasing evidence for the role of impaired intestinal permeability in obesity and associated metabolic diseases. Zonulin is an established serum marker for intestinal permeability and identical to pre-haptoglobin2. Here, we aimed to investigate the relationship between circulating zonulin and metabolic traits related to obesity. Serum zonulin was measured by using a widely used commercial ELISA kit in 376 subjects from the metabolically well-characterized cohort of Sorbs from Germany. In addition, haptoglobin genotype was determined in DNA samples from all study subjects. As zonulin concentrations did not correlate to the haptoglobin genotypes, we investigated the specificity of the zonulin ELISA assay using antibody capture experiments, mass spectrometry, and Western blot analysis. Using serum samples that gave the highest or lowest ELISA signals, we detected several proteins that are likely to be captured by the antibody in the present kit. However, none of these proteins corresponds to pre-haptoglobin2. We used increasing concentrations of recombinant pre-haptoglobin2 and complement C3 as one of the representative captured proteins and the ELISA kit did not detect either. Western blot analysis using both the polyclonal antibodies used in this kit and monoclonal antibodies rose against zonulin showed a similar protein recognition pattern but with different intensity of detection. The protein(s) measured using the ELISA kit was (were) significantly increased in patients with diabetes and obesity and correlated strongly with markers of the lipid and glucose metabolism. Combining mass spectrometry and Western blot analysis using the polyclonal antibodies used in the ELISA kit, we identified properdin as another member of the zonulin family. Our study suggests that the zonulin ELISA does not recognize pre-haptoglobin2, rather structural (and possibly functional) analog proteins belonging to the mannose-associated serine protease family, with properdin

  14. Different conformational forms of serum carnosinase detected by a newly developed sandwich ELISA for the measurements of carnosinase concentrations

    NARCIS (Netherlands)

    Adelmann, Katja; Frey, Dirk; Riedl, Eva; Koeppel, Hannes; Pfister, Frederick; Peters, Verena; Schmitt, Claus P.; Sternik, Paula; Hofmann, Stephanie; Zentgraf, Hans Walter; Navis, Gerjan; van den Born, Jacob; Bakker, Stephan J. L.; Kraemer, Bernhard K.; Yard, Benito A.; Hauske, Sibylle J.

    Serum carnosinase (CN-1) measurements are at present mainly performed by assessing enzyme activity. This method is time-consuming, not well suited for large series of samples and can be discordant to measurements of CN-1 protein concentrations. To overcome these limitations, we developed sandwich

  15. Bayesian estimation of sensitivity and specificity of a commercial serum/milk ELISA against the Mycobacterium avium subsp. Paratuberculosis (MAP) antibody response for each lactation stage in Greek dairy sheep.

    Science.gov (United States)

    Angelidou, Elisavet; Kostoulas, Polychronis; Leontides, Leonidas

    2016-02-01

    A total of 854 paired milk and blood samples were collected from ewes of a Greek flock and used to estimate the sensitivity and specificity of a commercial ELISA for detection of Mycobacterium avium subsp. paratuberculosis (MAP) specific antibodies in each stage of lactation. We implemented Bayesian mixture models to derive the distributions of the test response for the healthy and the infected ewes. In the colostrum period, early, mid and late lactation stage the median values of the area under the curves (AUC) were 0.61 (95% credible interval: 0.50; 0.84), 0.61 (0.51;0.84), 0.65 (0.51;0.91), 0.65(0.51;0.89) for the serum ELISA and and 0.60 (0.50; 0.84), 0.61 (0.50; 0.84), 0.67(0.51; 0.91), 0.66(0.50; 0.90) for the milk ELISA, respectively. Both serum and milk ELISA had low to average overall discriminatory ability as measured by the area under the curves and comparable sensitivities and specificities at the recommended cutoffs. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Specificity of Toxocara ELISA in tropical populations.

    Science.gov (United States)

    Lynch, N R; Wilkes, L K; Hodgen, A N; Turner, K J

    1988-05-01

    The diagnosis of human infection by Toxocara canis relies heavily upon serological tests, the specificity of which can be inadequate in regions of endemic helminthiasis. When different population groups of tropical Venezuela were evaluated using ELISA based upon Toxocara excretory-secretory antigen (TcESA), solid-phase adsorption of the sera with extracts of a wide variety of non-homologous parasites revealed the existence of significant cross-reactivity. This was effectively and conveniently overcome when the test sera were incubated in the presence of the soluble parasite extracts in a competitive inhibition ELISA. The mean reduction of ELISA values caused by pre-adsorption of the sera tested was 32.2%, and that caused by competitive inhibition was 42.3%, the effects of these two procedures being strongly correlated (r = 0.83). The magnitude of the reduction was inversely proportional to the actual ELISA value (r = -0.55), and ranged from a mean of 68.0% in sera from apparently healthy individuals of medium-high socio-economic level, down to 28.1% in heavily parasitized Amazon indians. Ascaris showed the greatest degree of cross-reactivity in these tests, although under conditions of competitive inhibition even sera with high levels of antibody against this parasite could be negative in Toxocara ELISA. Western blotting revealed a major 81,400 D component that was shared between Ascaris and TcESA. Our results indicate that the competitive inhibition of cross-reactivity by soluble non-homologous parasite extracts provides a convenient and economical means of increasing the specificity of ELISA for the determination of the seroprevalence of toxocariasis in tropical populations.

  17. Increased Kappa/Lambda Hybrid Antibody in Serum Is a Novel Biomarker Related to Disease Activity and Inflammation in Rheumatoid Arthritis.

    Science.gov (United States)

    Yi, Lang; Hao, Mingju; Lu, Tian; Lin, Guigao; Chen, Lida; Gao, Ming; Fan, Gaowei; Zhang, Dong; Wang, Guojing; Yang, Xin; Li, Yulong; Zhang, Kuo; Zhang, Rui; Han, Yanxi; Wang, Lunan; Li, Jinming

    2016-01-01

    The κ/λ hybrid antibodies in normal human serum were reported recently, but their clinical relevance has not yet been explored. Rheumatoid arthritis (RA) is one of the major joint diseases, and the early diagnosis and treatment of RA remain a challenge. Here, we developed a double-sandwich enzyme-linked immunosorbent assay system to quantify relative serum κ/λ hybrid antibody levels in RA patients, osteoarthritis (OA) patients, and healthy controls (HC) in order to assess their potential use as a serological biomarker of early disease and clinical activity and to preliminarily investigate their immunomodulatory roles in RA. Surprisingly, we found that κ/λ hybrid antibody was markedly increased in both early and established RA. Serum κ/λ hybrid antibody levels were significantly correlated with clinical indexes and inflammatory markers in RA. Further analysis showed a positive correlation between κ/λ hybrid antibody levels and the 28-joint disease activity score (DAS28). In conclusion, serum κ/λ hybrid antibodies in RA were identified for the first time. High levels of κ/λ hybrid antibody may be a useful tool in distinguishing early RA from OA and HC. We suggest κ/λ hybrid antibody as a marker for disease activity. The increased κ/λ hybrid antibodies were associated with inflammatory conditions in RA.

  18. Heterogeneity of neutrophil antibodies in patients with primary Sjögren's syndrome.

    Science.gov (United States)

    Lamour, A; Le Corre, R; Pennec, Y L; Cartron, J; Youinou, P

    1995-11-01

    Our aims were to determine the prevalence of neutrophil antibodies in patients with primary Sjögren's syndrome (pSS), identify their target antigen(s), and evaluate their functional significance. Neutrophil antibodies were detected using an indirect immunofluorescence (IIIF) test and an enzyme-linked immunosorbent assay (ELISA), using recombinant human Fc-gamma receptor (Fc gamma RIIIb) as a capture agent. Luminol-dependent chemiluminescence was then measured by an established technique. Antibodies to neutrophils were detected in 30 of 66 patients (45%) and categorized on the basis of positivity for the two assays: IIF+/ELISA+ (group A: five patients), IIF+/ELISA- (group B: five patients), and IFF-/ELISA+ (group C: 20 patients). All positive sera contained antibodies directed to the neutrophil specific Fc gamma RIIIb, and none of them bound to NAnull neutrophils. The titer of neutrophil-reactive antibodies (groups A and B) showed no correlation with the neutrophil count, but these autoantibodies did reduce the cell ability to generate a respiratory burst. Thus, neutrophil antibodies are common in patients with pSS. Their main target appears to be Fc gamma RIII, and this may partly account for the dysfunction in Fc gamma R-mediated clearance by the reticuloendothelial system reported in these patients.

  19. Evaluation of an enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of sarcoptic mange in dogs.

    Science.gov (United States)

    Lower, K S; Medleau, L M; Hnilica, K; Bigler, B

    2001-12-01

    Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.

  20. SIGNS The sandwich sign

    African Journals Online (AJOL)

    The sandwich sign is demonstrated on cross-sectional imaging, commonly on CT or ultrasound. It refers to homogeneous soft- tissue masses representing mesenteric lymphadenopathy as the two halves of a sandwich bun, encasing the mesenteric fat and tubular mesenteric vessels that constitute the 'sandwich filling' (Figs ...

  1. Prevalence of Peste Des Petits Ruminants Virus (PPRV in Mardan, Hangu and Kohat District of Pakistan; Comparative Analysis of PPRV Suspected serum samples using Competitive ELISA (cELISA and Agar Gel Immunodiffusion (AGID

    Directory of Open Access Journals (Sweden)

    Misbah Aslam

    2009-06-01

    Full Text Available Peste des petits Ruminants (PPR is an acute, febrile, highly contagious and economically important viral disease of small ruminants. However PPR is more prevalent in sheep and goat. Competitive ELISA, Virus neutrilization test, and RT-PCR are the available techniques for diagnosis of PPR which give rapid detection where as Agar gel immunodiffusion and Counter immunoelectrophoresis were previously used for PPR detection. In this study two serological techniques were compared for PPR diagnosis. The main aim of this study was to evaluate the comparative sensitivity of both techniques for PPR detection. For this purpose one hundred and sixty PPR suspected serum samples collected from goats and sheep flocks (unvaccinated from three Districts of NWFP including Mardan, Hangu and Kohat were analyzed in National Veterinary Laboratories, Islamabad. Out of these 160 samples, fifty (50 were found positive for PPR antibodies with cELISA (Prevalence = 31.25%. The cELISA positive serum samples however gave negative results when tested with AGID although the control well was always positive. Thus it was concluded that cELISA technique is more sensitive and specific than AGID for PPR antibody detection. [Vet. World 2009; 2(3.000: 89-92

  2. Isolation of recombinant phage antibodies targeting the hemagglutinin cleavage site of highly pathogenic avian influenza virus.

    Directory of Open Access Journals (Sweden)

    Jinhua Dong

    Full Text Available Highly pathogenic avian influenza (HPAI H5N1 viruses, which have emerged in poultry and other wildlife worldwide, contain a characteristic multi-basic cleavage site (CS in the hemagglutinin protein (HA. Because this arginine-rich CS is unique among influenza virus subtypes, antibodies against this site have the potential to specifically diagnose pathogenic H5N1. By immunizing mice with the CS peptide and screening a phage display library, we isolated four antibody Fab fragment clones that specifically bind the antigen peptide and several HPAI H5N1 HA proteins in different clades. The soluble Fab fragments expressed in Escherichia coli bound the CS peptide and the H5N1 HA protein with nanomolar affinity. In an immunofluorescence assay, these Fab fragments stained cells infected with HPAI H5N1 but not those infected with a less virulent strain. Lastly, all the Fab clones could detect the CS peptide and H5N1 HA protein by open sandwich ELISA. Thus, these recombinant Fab fragments will be useful novel reagents for the rapid and specific detection of HPAI H5N1 virus.

  3. Novel sensitive monoclonal antibody based competitive enzyme-linked immunosorbent assay for the detection of raw and processed bovine beta-casein.

    Science.gov (United States)

    Castillo, Daniela S; Cassola, Alejandro

    2017-01-01

    Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention.

  4. Elisa development for detection of glyphosat resistant gm soybean

    Directory of Open Access Journals (Sweden)

    Владислав Геннадійович Спиридонов

    2015-11-01

    Full Text Available During research we have utilized recombinant enzyme 5-enolpyruvylshikimate-3-phosphate synthase (CP4 EPSPS, conferring resistance to glyphosate for GM soybean, for the hen immunization and obtaining specific yolk antibodies IgY. Stages of ELISA development that can detect at least 0,1 % of GM-soybean resistant to glyphosate were present

  5. Diagnostic utility of egg yolk for the detection of avian metapneumovirus antibodies in laying hens.

    Science.gov (United States)

    Choi, Kang-Seuk; Lee, Eun-Kyoung; Jeon, Woo-Jin; Park, Mi-Ja; Yoo, Yae-Na; Kwon, Jun-Hun

    2010-12-01

    Surveillance and diagnosis of avian metapneumovirus (AMPV) infection typically involve measurement of serum antibodies. In the current study, eggs instead of serum samples were used for the detection of AMPV antibodies in egg-laying chicken hens by enzyme-linked immunosorbent assay (ELISA). AMPV-free commercial layer hens were experimentally challenged with AMPV strain SC1509 through intravenous or oculonasal administration. Antibody levels were determined by ELISA. AMPV antibodies were detected in egg yolks from challenged hens by 7 days postinoculation (dpi), with the peak titer at 16 dpi. Antibody levels in eggs laid at 28 dpi correlated well (r = 0.93) with sera taken 28 dpi from the same hens. In a field trial of the yolk ELISA, six broiler breeder farms were surveyed, and all tested positive for AMPV antibodies in hen eggs, although positivity varied from farm to farm. Abnormal discolored eggs collected from outbreak farms had significantly higher titers of AMPV yolk antibodies than normal eggs from the same farm, unlike clinically healthy farms, where normal and abnormal eggs had similar antibody titers. These results indicate that diagnosis of AMPV infection by yolk ELISA to detect anti-AMPV antibodies may be a suitable alternative to serologic testing.

  6. Autoantibodies to the Rpp25 component of the Th/To complex are the most common antibodies in patients with systemic sclerosis without antibodies detectable by widely available commercial tests.

    Science.gov (United States)

    Mahler, Michael; Satoh, Minoru; Hudson, Marie; Baron, Murray; Chan, Jason Y F; Chan, Edward K L; Wick, James; Fritzler, Marvin J

    2014-07-01

    Antinuclear antibodies (ANA) occur in up to 95% of patients with systemic sclerosis (SSc). In most, SSc-associated antibodies are detected (i.e., centromere, topoisomerase I, RNA polymerase III, PM/Scl, Ro52/TRIM21, and U1RNP). Ribonuclease P protein subunit p25, (Rpp25) is an autoantigenic component of the Th/To complex. The contribution of anti-Th/To and anti-Rpp25 antibodies to ANA positivity in patients with SSc remains unknown. Sera from 873 patients with SSc were tested for ANA, and SSc-associated antibodies were measured. Samples without antibodies to extractable nuclear antigens (ENA; n = 53, ANA+/ENA-), were analyzed by immunoprecipitation (IP) and metabolically labeled proteins and for anti-Rpp25 antibodies (n = 50) by a chemiluminescent immunoassay (CLIA) and Rpp25 ELISA. Anti-Th/To antibodies occurred in 19/53 (36%), as determined by IP, and were the most common autoantibody in ANA+/ENA- SSc. Of those samples, 50/53 were available for additional testing by CLIA and ELISA. Anti-Rpp25 antibodies were detected in 12 (24% CLIA) or 10 (20% ELISA) of 50 patients. Receiver-operating characteristic curve analysis showed similar discrimination between Th/To IP-positive (n = 19) and -negative samples (n = 31) by CLIA and ELISA (area under the curve 0.90 vs 0.87; p = 0.6691). The positive percent agreement between IP and CLIA or ELISA was 12/19 (63.2%, 95% CI 38.4-83.7%) or 10/19 (52.6%, 95% CI 73.3-94.2%), respectively. Negative percent agreement was 100% for both assays. Autoantibodies to the Th/To autoantigen are important in patients with SSc who have been considered negative for SSc-specific or SSc-associated antibodies by widely available commercial assays. Rpp25 can be considered a major target of anti-Th/To antibodies. Assays detecting anti-Th/To and anti-Rpp25 antibodies may be important in SSc.

  7. Validation of pre-coated ELISA tests to detect antibodies against T. congolense and T. vivax

    International Nuclear Information System (INIS)

    Shumba, W.

    2000-01-01

    The anti-trypanosomal antibody detecting enzyme linked immunosorbent assay (ELISA) was first described in 1977 and was further developed for use in large scale surveys in Zimbabwe. More recently, the IAEA initiated a programme to improve the robustness and standardisation of the assay. The IAEA supplied plates pre-coated with either a crude T. congolense or T. vivax antigen and the reagents necessary for analysing samples. Parasitologically positive and negative sera were used to validate and determine the cut-off values of the two tests. The samples were tested and results analysed using a variety of cut-off values. The tests provided similar information although the T. congolense pre-coated plates gave significantly higher optical density values than the plates coated with T. vivax. Sensitivity and specificity values were calculated using the different cut-off points. Results indicate that the test using T. congolense antigen had the highest specificity and sensitivity for a given cut-off value. Although the test could distinguish positive from negative sera, it was quite difficult to provide a suitable cut-off value, but the value should be dictated by the use of the test. (author)

  8. Enzyme-linked immunosorbent Assay for detecting of antibody to canine distemper virus

    Directory of Open Access Journals (Sweden)

    Sudarisman

    2006-03-01

    Full Text Available Serum neutralisation test (SNT has been established for evaluating canine distemper vaccination, but until now SNT was rarely used due to the need for continuous tissue culture facilities and requires 3 days to perform. For detecting antibody to canine distemper virus, an enzyme-linked immunosorbent assay (ELISA is relatively simple and rapid seroassay. ELISA for canine immunoglobulin (Ig G antibodies to canine distemper virus (CDV was developed by using Onderstepoort strain of canine distemper virus as coating antigen. Rabbit anti canine IgG labelled with horse radish peroxidase was used as the conjugate, while phenylenediamine dihydrochloride (OPD was used as the substrate. The ELISA results were then compared with the results of the SNT, using the sera of 312 random-source dogs from West Java. The two test-results had a high degree of correlation. Very few discrepancies occurred and most of these were at the lower limits of each test. When the sera were tested at 1 : 100 dilutions, there was a 95.5% agreement between the ELISA and SNT. Their sensitivity and spesificity were 83.9 and 98.4%. Titrated SNT and ELISA also were performed on sera from 7 dogs whose lifetime medical histories were known. The antibodies were inclining up after two months of post vaccination, where the titre was not in zero/lower position at the day of vaccination. However, antibody zero or low position were found at 28 days post vaccination. All of the results indicated that ELISA can be used for evaluating antibody to canine distemper virus response, replacing the SNT.

  9. Highly sensitive immunoassay based on E. coli with autodisplayed Z-domain

    International Nuclear Information System (INIS)

    Jose, Joachim; Park, Min; Pyun, Jae-Chul

    2010-01-01

    The Z-domain of protein A has been known to bind specifically to the F c region of antibodies (IgGs). In this work, the Z-domain of protein A was expressed on the outer membrane of Escherichia coli by using 'Autodisplay' technology as a fusion protein of autotransport domain. The E. coli with autodisplayed Z-domain was applied to the sandwich-type immunoassay as a solid-support of detection-antibodies against a target analyte. For the feasibility demonstration of the E. coli based immunoassay, C-reactive protein (CRP) assay was carried out by using E. coli with autodisplayed Z-domain. The limit of detection (LOD) and binding capacity of the E. coli based immunoassay were estimated to be far more sensitive than the conventional ELISA. Such a far higher sensitivity of E. coli based immunoassay than conventional ELISA was explained by the orientation control of immobilized antibodies and the mobility of E. coli in assay matrix. From the test results of 45 rheumatoid arthritis (RA) patients' serum and 15 healthy samples, a cut-off value was established to have optimal sensitivity and selectivity values for RA. The CRP test result of each individual sample was compared with ELISA which is the reference method for RA diagnosis. From this work, the E. coli with Z-domain was proved to be feasible for the medical diagnosis based on sandwich-type immunoassay.

  10. ELISA MEASUREMENT OF STACHYLYSIN (TM) IN SERUM TO QUANTIFY HUMAN EXPOSURES TO THE INDOOR MOLD STACHYBOTRYS CHARTARUM

    Science.gov (United States)

    Antibodies were produced against the hemolytic agent stachylysin obtained from the mold Stachybotryis chartarum. These antibodies were used to develop two enzyme-linked immunosorbent assay (ELISA) methods for the analysis of stachylysin in human and rat sera and environmental sa...

  11. Homologous ELISA for detection of oligomeric human TNF: properties of the assay.

    Science.gov (United States)

    Petyovka, N; Lyach, L; Voitenok, N N

    1995-10-26

    In order to quantify oligomeric human tumor necrosis factor-alpha (TNF), we have developed a sensitive homologous enzyme-linked immunosorbent assay (Hm-ELISA) using the same monoclonal antibody (MoAb) for both solid and liquid phase. Different anti-TNF MoAb have been compared in terms of their efficacy in the Hm-ELISA, affinity, neutralization capacity and epitope specificity. The data suggest, that effectiveness in the Hm-ELISA may represent a novel characteristic of MoAb. Of the MoAbs tested, 5 N was capable of recognizing oligomeric TNF in the Hm-ELISA with a detection limit of 15 pg/ml. Furthermore, using Hm-ELISA against human TNF, interleukin-8 (IL-8) and lymphotoxin, we have demonstrated that these cytokines are oligomeric in physiological solutions, but are converted into monomeric forms in the presence of the non-ionic detergent Tween 20. High salt buffer was employed to abrogate a nonspecific false positive reaction in the Hm-ELISA found in nearly half of the plasma samples obtained from healthy subjects. Finally, a good correlation between the Hm-ELISA and the L929 bioassay was observed for natural and recombinant TNF measured in human plasma.

  12. Detection of Francisella tularensis-Specific Antibodies in Patients with Tularemia by a Novel Competitive Enzyme-Linked Immunosorbent Assay

    Science.gov (United States)

    Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio

    2013-01-01

    A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700

  13. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 Human IgG Antibody Produced by AnaptysBio, Inc.

    Science.gov (United States)

    2016-02-01

    Enzyme- linked immunosorbent assay (ELISA) Quality Testing MS2 coat protein (MS2CP) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...primarily relied on the performance of an antibody in an enzyme- linked immunosorbent assay (ELISA), with little regard for quantifying the full spectrum...Protection, and Multi-Year Stabilization, in High Concentration Protein Solutions, Using Ionic Liquids. Chem. Commun. (Camb) 2007, 26, 2714–2716. 3. Bio

  14. Enzyme-Linked Immunosorbent Assay Testing of Shoots Grown In Vitro and the Use of Immunocapture-Reverse Transcription-Polymerase Chain Reaction Improve the Detection of Prunus necrotic ringspot virus in Rose.

    Science.gov (United States)

    Moury, B; Cardin, L; Onesto, J P; Candresse, T; Poupet, A

    2000-05-01

    We developed and evaluated two different methods to improve the detection of the most prevalent virus of rose in Europe, Prunus necrotic ring-spot virus (PNRSV). Immunocapture-reverse transcription-polymerase chain reaction was estimated to be about 100 times more sensitive than double-antibody sandwich-enzyme-linked immunosorbent assay (DAS-ELISA) and showed an equivalent specificity. Based on the observation that PNRSV multiplies actively in young growing tissues (axillary shoots and cuttings), an in vitro culture method allowing rapid (about 15 days) and homogeneous development of dormant axillary buds with high virus titers was standardized. ELISA tests of these young shoots showed, in some cases, a 10(4) to 10(5) increase in sensitivity in comparison to adjacent leaf tissues from the rose mother plants. Between 21 and 98% (depending on the season) more samples were identified as positive by using ELISA on samples from shoot tips grown in vitro rather than on leaves collected directly from the PNRSV-infected mother plants. This simple method of growing shoot tips in vitro improved the confidence in the detection of PNRSV and eliminated problems in sampling appropriate tissues.

  15. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    Directory of Open Access Journals (Sweden)

    Ondigo Bartholomew N

    2012-12-01

    Full Text Available Abstract Background Multiplex cytometric bead assay (CBA have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.

  16. Detection of antibodies to the extractable nuclear antigens by enzyme linked immunosorbent assay

    International Nuclear Information System (INIS)

    Aziz, Khalil A.; Fzizal, Abul A.

    2005-01-01

    Anti-extractable nuclear antigen (ENA) antibodies are a group of autoantibodies that are directed against various components of the cell nucleus. Antibodies to these antigens are closely associated with connective tissue disease. Early diagnosis of these diseases can prove very difficult and therefore clinicians rely on the use of anti-ENA antibody testing for the exclusion. Old methods of testing are time consuming and require great skills. For these reasons clinical immunology laboratories are switching to testing for anti-ENA antibodies by enzyme linked immunosorbent assay (ELISA). The latter assays are more sensitive and require little skills. In the present study we have investigated a number of different ELISA preparations. The study was conducted at Birmingham Heartlands Hospital during the period 2003. We tested a number of ENA-positive and negative samples using 3 different commercial ELISA preparations and compared the results with traditional CCIE-assay. The present study revealed that some ELISA preparations can be more sensitive than CCIE method. Laboratories still using later method should switch to ELISA. However it is important that laboratories evaluate a long range of different ELISA preparations before selecting the most optimal one. In addition it is recommended that laboratories then audit results in order to determine true significance of such results. Finally until the true significance of ELISA generated results is known, positive ENA-results should be interpreted in conjunction with the clinical picture and this would require close liaison in between the clinical immunology laboratory and clinicians

  17. Detection by radioimmunoassay and enzyme-linked immunosorbent assay of coronavirus antibodies in bovine serum and lacteal secretions.

    Science.gov (United States)

    Rodak, L; Babiuk, L A; Acres, S D

    1982-07-01

    The sensitivity of a radioimmunoassay (RIA), an enzyme-linked immunosorbent assay (ELISA), and a serum neutralization assay (SN) for detecting antibodies to bovine coronavirus in serum and colostrum were compared. Although there proved to be a good correlation among all three assays (r = 0.915 and 0.964 for RIA with SN and ELISA, respectively), RIA and ELISA proved to be at least 10 times more sensitive than neutralization tests. By using these techniques, it was possible to detect a time-dependent decrease in antibody levels in bovine colostrum after parturition. Using ELISA, we demonstrated that 12 of 12 herds in Saskatchewan, and 109 of 110 animals tested, and antibody to bovine coronavirus. There was no elevated antibody response in serum or lacteal secretions of cows vaccinated once or twice with a commercially available modified live rota-coronavirus vaccine. In addition to being more sensitive than SN, ELISA and RIA proved to have other advantages for measuring antibody levels to bovine coronavirus and therefore warrant wider use as tools in diagnostic virology.

  18. Flotation Immunoassay: Masking the Signal from Free Reporters in Sandwich Immunoassays.

    Science.gov (United States)

    Chen, Hui; Hagström, Anna E V; Kim, Jinsu; Garvey, Gavin; Paterson, Andrew; Ruiz-Ruiz, Federico; Raja, Balakrishnan; Strych, Ulrich; Rito-Palomares, Marco; Kourentzi, Katerina; Conrad, Jacinta C; Atmar, Robert L; Willson, Richard C

    2016-04-14

    In this work, we demonstrate that signal-masking reagents together with appropriate capture antibody carriers can eliminate the washing steps in sandwich immunoassays. A flotation immunoassay (FI) platform was developed with horseradish peroxidase chemiluminescence as the reporter system, the dye Brilliant Blue FCF as the signal-masking reagent, and buoyant silica micro-bubbles as the capture antibody carriers. Only reporters captured on micro-bubbles float above the dye and become visible in an analyte-dependent manner. These FIs are capable of detecting proteins down to attomole levels and as few as 10(6) virus particles. This signal-masking strategy represents a novel approach to simple, sensitive and quantitative immunoassays in both laboratory and point-of-care settings.

  19. Carbamylated albumin is one of the target antigens of anti-carbamylated protein antibodies.

    Science.gov (United States)

    Nakabo, Shuichiro; Hashimoto, Motomu; Ito, Shinji; Furu, Moritoshi; Ito, Hiromu; Fujii, Takao; Yoshifuji, Hajime; Imura, Yoshitaka; Nakashima, Ran; Murakami, Kosaku; Kuramoto, Nobuo; Tanaka, Masao; Satoh, Junko; Ishigami, Akihito; Morita, Satoshi; Mimori, Tsuneyo; Ohmura, Koichiro

    2017-07-01

    Anti-carbamylated protein (anti-CarP) antibodies are detected in RA patients. Fetal calf serum is used as an antigen source in anti-CarP ELISA, and the precise target antigens have not been found. We aimed to identify the target antigens of anti-CarP antibodies. Western blotting of anti-CarP antibodies was conducted. Anti-carbamylated human albumin (CarALB) antibody was detected by in-house ELISA for 493 RA patients and 144 healthy controls (HCs). An inhibition ELISA of anti-CarP antibodies by CarALB and citrullinated albumin (citALB) was performed using eight RA patients' sera. Serum CarALB was detected by liquid chromatography-tandem mass spectroscopy (LC/MS/MS), and the serum MPO concentration was measured by ELISA. We focused on carbamylated albumin because it corresponded to the size of the thickest band detected by western blotting of anti-CarP antibodies. Anti-CarALB antibody was detected in 31.4% of RA patients, and the correlation of the titres between anti-CarALB and anti-CarP was much closer than that between anti-citALB and anti-CCP antibodies (ρ = 0.59 and ρ = 0.16, respectively). The inhibition ELISA showed that anti-CarP antibodies were inhibited by CarALB, but not by citALB. CarALB was detected in sera from RA patients by LC/MS/MS. The serum MPO concentration was correlated with disease activity and was higher in RA patients with anti-CarALB antibody than in those without. We found that carbamylated albumin is a novel target antigen of anti-CarP antibodies, and it is the first reported target antigen that has not been reported as the target of ACPA. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  20. Detection of antibodies against Sarcocystis neurona, Neospora spp., and Toxoplasma gondii in horses from Costa Rica.

    Science.gov (United States)

    Dangoudoubiyam, S; Oliveira, J B; Víquez, C; Gómez-García, A; González, O; Romero, J J; Kwok, O C H; Dubey, J P; Howe, D K

    2011-06-01

    Serum samples from 315 horses from Costa Rica, Central America, were examined for the presence of antibodies against Sarcocystis neurona, Neospora spp., and Toxoplasma gondii by using the surface antigen (SAG) SnSAG2 enzyme-linked immunosorbent assay (ELISA), the NhSAG1 ELISA, and the modified agglutination test, respectively. Anti- S. neurona antibodies were found in 42.2% of the horses by using the SnSAG2 ELISA. Anti- Neospora spp. antibodies were found in only 3.5% of the horses by using the NhSAG1 ELISA, and only 1 of these horses was confirmed seropositive by Western blot. Antibodies to T. gondii were found in 34.0% of the horses tested, which is higher than in previous reports from North and South America. The finding of anti- S. neurona antibodies in horses from geographical areas where Didelphis marsupialis has wide distribution suggests that D. marsupialis is a potential definitive host for this parasite and a source of infection for these horses.

  1. ELISA-PLA: A novel hybrid platform for the rapid, highly sensitive and specific quantification of proteins and post-translational modifications.

    Science.gov (United States)

    Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie

    2016-06-15

    Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Testing of the scintillation sandwich prototype

    International Nuclear Information System (INIS)

    Vashkevich, V.

    1995-06-01

    The 3 m 2 prototype of the surface detector using optical fiber readout was completely prepared for testing measurements in February 1995 at Fermilab. Two 25 mm thick, 3 m 2 acrylic scintillation plates (1.2 x 2.5 m 2 ) are used for light collection in the upper (above the 25 mm steel plate) and lower (below the steel) counters of the sandwich. The light is collected with the help of 1 mm diameter wavelength shifter fiber loops 3 m long inserted in the grooves on the top surface of the scintillator, 3 fibers per groove. We used Kurary Y11, 200 ppm of shifter dye, and double clad fibers. 1.5 m of clear fibers spliced to each end of the shifter fiber transport the light to the phototube. Spacing between the grooves is 5 cm. The counter's edges were painted with BICRON (BC620) white reflective paint. The scintillation plates were wrapped with Dupont Tyvek. The glued bundle of fibers is connected to an EMI-9902KB 38 mm phototube through the simple light mixer bar. Used PM has a ''green extended'' rubidium bialkali photocathode. The report contains information on the testing of the scintillation sandwich

  3. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    Science.gov (United States)

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  4. Use of avidin-biotin-peroxidase complex for measurement of UV lesions in human DNA by microELISA

    Energy Technology Data Exchange (ETDEWEB)

    Leipold, B [Technischen Universitaet Muenchen (Germany, F.R.). Dermatologische Klinik; Remy, W [Max-Planck-Institut fuer Biochemie, Muenchen (Germany, F.R.)

    1984-02-10

    The avidin/biotin system was introduced into the standard enzyme-linked immunosorbent assay (ELISA) to increase its sensitivity for detecting UV lesions in human DNA. Goat anti-rabbit IgG-peroxidase used in the standard ELISA as second antibody was replaced by biotinylated goat anti-rabbit IgG plus the avidin-biotin-peroxidase complex (ABC) reagent. Sensitivity of detection of plate-fixed UV-DNA-antibody complexes was increased about 8-fold and photolesions in human DNA samples irradiated with as low a dose as 1 J/m/sup 2/ UVC or a suberythermal dose of UVB light could be detected.

  5. Validation of an IgM antibody capture ELISA based on a recombinant nucleoprotein for identification of domestic ruminants infected with Rift Valley fever virus.

    Science.gov (United States)

    Williams, Roy; Ellis, Charlotte Elizabeth; Smith, Shirley Jacqueline; Potgieter, Christiaan Abraham; Wallace, David; Mareledwane, Vuyokazi Epipodia; Majiwa, Phelix Antipas Ochola

    2011-11-01

    The presence of competent vectors in some countries currently free of Rift Valley fever (RVF) and global changes in climate, travel and trade have increased the risk of RVF spreading to new regions and have emphasised the need for accurate and reliable diagnostic tools for early diagnosis during RVF outbreaks. Highly sensitive viral detection systems like PCR have a limited use during outbreaks because of the short duration of viraemia, whereas antibodies like specific IgM which are serological indicators of acute infection, can be detected for up to 50 days after infection. Using the highly conserved and immunogenic recombinant nucleoprotein of RVF virus in an IgM capture ELISA, the risk of laboratory infection associated with traditional serological methods is avoided. The use of pre-coated/pre-blocked ELISA plates and the conjugation of the recombinant nucleoprotein with horseradish peroxidase simplified and shortened the assay procedure. Results showed the assay to be highly reproducible with a lower detection limit equal to that of a commercial competition ELISA. By receiver operating characteristic (ROC) curve analysis the area under curve (AUC) index was determined as 1.0 and the diagnostic sensitivity and specificity at a PP cut-off value of 4.1 as 100% and 99.78% respectively. The results of this study demonstrated that the IgM capture ELISA is a safe, reliable and highly accurate diagnostic tool which can be used on its own or in parallel with other methods for the early diagnosis of RVF virus infection and also for monitoring of immune responses in vaccinated domestic ruminants. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Bioinspired metal-cell wall-metal sandwich structure on an individual bacterial cell scaffold.

    Science.gov (United States)

    Zhang, Xiaoliang; Yu, Mei; Liu, Jianhua; Li, Songmei

    2012-08-25

    Pd nanoparticles were introduced to individual Bacillus cells and dispersedly anchored on both the inside and outside of the cell walls. The anchored nanoparticles served as "seeds" to drive the formation of double metallic layers forming a metal-cell wall-metal sandwich structure at the single-cell level.

  7. Development of surface plasmon resonance imaging for detection of Acidovorax avenae subsp. citrulli (Aac) using specific monoclonal antibody.

    Science.gov (United States)

    Puttharugsa, Chokchai; Wangkam, Thidarat; Huangkamhang, Nongluck; Gajanandana, Oraprapai; Himananto, Orawan; Sutapun, Boonsong; Amarit, Ratthasart; Somboonkaew, Armote; Srikhirin, Toemsak

    2011-01-15

    An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10(6)cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10(5) cfu/ml. The LOD for the ELISA technique was 5×10(4) cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Anti-double strand (ds) DNA antibody formation by NZB/W (F1) spleen cells in a microculture system detected by solid phase radioimmunoassay.

    Science.gov (United States)

    Okudaira, H; Terada, E; Ogita, T; Aotsuka, S; Yokohari, R

    1981-01-01

    A solid-phase radioimmunoassay method was devised to detect mouse anti-double strand (ds) DNA antibody. This method could easily detect the anti-dsDNA antibody in 1 : 10,000 dilutions (1 unit) of pooled 9-10-month-old female NZB/W F1 sera. The sensitivity was about 10(3)- and 10(2)-fold higher than that of the modified Farr method and of the double antibody technique respectively. NZB/W mice developed high titer anti-dsDNA antibody as they grew older. Spleen cells brought to a microculture system using flat-bottomed polystyrene plates produced anti-dsDNA antibody clearly detectable by solid-phase radioimmunoassay. Anti-dsDNA antibody produced in vitro (y units) was in close correlation with the anti-dsDNA antibody titer of the spleen donor (x units) (y = 4.8 X 10(-2) x -65, gamma = 0.94, P less than 0.001). A combination of the microculture system and solid-phase radioimmunoassay was recommended for the characterization of anti-dsDNA antibody-forming cells.

  9. Anti-double strand (ds) DNA antibody formation by NZB/W (F1) spleen cells in a microculture system detected by solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Okudaira, H.; Terada, E.; Ogita, T.; Aotsuka, S.; Yokohari, R.

    1981-01-01

    A solid-phase radioimmunoassay method was devised to detect mouse anti-double strand (ds) DNA antibody. This method could easily detect the anti-ds DNA antibody in 1 : 10,000 dilutions (1 unit) of pooled 9-10 month-old female NZB/W F1 sera. The sensitivity was about 10 3 and 10 2 -fold higher than that of the modified Farr method and of the double antibody technique respectively. NZB/W mice developed high titer anti-dsDNA antibody as they grew older. Spleen cells brought to a microculture system using flat-bottomed polystyrene plates produced anti-dsDNA antibody clearly detectable by solid-phase radioimmunoassay. Anti-dsDNA antibody produced in vitro (y units) was in close correlation with the anti-dsDNA antibody titer of the spleen donor (x units) (y = 4.8 X 10 -2 x-65, γ = 0.94, P < 0.001). A combination of the microculture system and solid-phase radioimmunoassay was recommended for the characterization of anti-dsDNA antibody-forming cells. (Auth.)

  10. Merozoite proteins from Babesia sp. BQ1 (Lintan) as potential antigens for serodiagnosis by ELISA.

    Science.gov (United States)

    Guan, G Q; Chauvin, A; Rogniaux, H; Luo, J X; Yin, H; Moreau, E

    2010-05-01

    Babesia sp. BQ1 (Lintan) is a Babesia isolated from sheep infested with Haemaphysalis qinghaiensis in China, and is closely related to B. motasi based on the 18S rRNA gene sequence. In the present study, an ELISA was developed with merozoite antigens of Babesia sp. BQ1 (Lintan) (BQMA) purified from in vitro culture. When the positive threshold was chosen as 30% of the antibodies rate, evaluated with 198 negative sera, the specificity was 95.5%. Except for Babesia sp. Tianzhu, there was no cross-reaction between BQMA and positive sera from Babesia sp. BQ1 (Ningxian)-, Babesia sp. Hebei-, Babesia sp. Xinjiang-, Theileria luwenshuni-, T. uilenbergi-, or Anaplasma ovis-infected sheep, which are the dominant haemoparasites of small ruminants in China. Specific antibodies against Babesia sp. BQ1 (Lintan) were produced 1 or 2 weeks post-infection and a high level of antibodies persisted for more than 8 months in experimentally infected sheep. This ELISA was tested on 974 sera collected from field-grazing sheep in 3 counties of Gansu province, northwestern China to evaluate the seroprevalence of Babesia sp. BQ1 (Lintan) infection and the average positive rate was 66.84%. The feasibility of increasing the specificity of this BQMA-based ELISA, by using some BQMA antigens for serodiagnosis is discussed.

  11. Measurement of anti-double-stranded DNA antibodies in major immunoglobulin classes

    Energy Technology Data Exchange (ETDEWEB)

    Aotsuka, S; Okawa, M; Ikebe, K; Yokohari, R [Division of Clinical Immunology, Clinical Research Institute, National Medical Center Hospital, Shinjuku-ku, Tokyo, Japan

    1979-07-10

    A solid-phase radioimmunoassay for quantitating anti-double-stranded deoxyribonucleic acid antibodies (anti-dsDNA) in IgG, IgM and IgA classes has been devised. A distinct feature of the method is an application of polystyrene tubes coated with poly-L-lysine, through which dsDNA could be bound firmly to a solid phase. Studies on patients sera as well as normal sera revealed that anti-dsDNA was not qualitatively but quantitatively characteristic of systematic lupus erythematosus (SLE) and that IgG anti-dsDNA levels correlated well with the disease activity.

  12. Enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody as a new tool to detect Sudan dyes and Para red

    International Nuclear Information System (INIS)

    Ju Chunmei; Tang Yong; Fan Huiying; Chen Jinding

    2008-01-01

    To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL -1 in phosphate-buffered saline (PBS) buffer and 0.5 ng g -1 in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products

  13. Enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody as a new tool to detect Sudan dyes and Para red

    Energy Technology Data Exchange (ETDEWEB)

    Ju Chunmei [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China); Tang Yong [Center of Antibody Engineering, Department of Bioengineering, Jinan University, Guangzhou 510632 (China); Fan Huiying [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China); Chen Jinding [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China)], E-mail: jdchen@scau.edu.cn

    2008-07-28

    To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL{sup -1} in phosphate-buffered saline (PBS) buffer and 0.5 ng g{sup -1} in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products.

  14. The Diagnostic Value of ELISA Method for Pertussis in Children

    Directory of Open Access Journals (Sweden)

    O. P. Popova

    2016-01-01

    Full Text Available Because of low effectiveness of laboratory methods for diagnosing pertussis it is important to look for new ways of verification of this infection. The article presents the analysis of the diagnostic value of ELISA method, which involves the identification of antibodies of different isotypes (IgM, IgG, IgA to pertussis toxoid (PT and filamentous haemagglutinin (FHA. The study included 279 children: 114 were under 1 year of age, 165 — older than 1 year. The pertussis was confirmed in 74.3 ± 2.6% of patients by using ELISA method. A significant proportion of seronegative patients (46.1 ± 6.2 per cent was revealed in the group of patients under 1 year. The pattern of production of antibodies in unvaccinated children was different. It depended on the age of the children and timing of illness. A low proportion of diagnostically significant indicators of IgM-antibodies at 2—3 weeks of illness was typical for patients under 1 year of age (e.g. 6.7 ± 6.5% as compared to 20.0 ± 7.9% and 50.0 ± 15.3 — 1—3 and 4—6 years of age. The diagnosis of pertussis in children under 1 year of age was confirmed mainly by the detection of IgG, starting from the 4th week of the disease. In the examination of vaccinated children diagnostically significant levels of IgA and IgG were identified (even in the late stages of the disease. Thus, the results of the analysis show special significance of using ELISA method for the diagnosis of pertussis in vaccinated children.

  15. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    Directory of Open Access Journals (Sweden)

    Nadja Sparding

    Full Text Available After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  16. Quantum dot-linked immunosorbent assay (QLISA) using orientation-directed antibodies.

    Science.gov (United States)

    Suzuki, Miho; Udaka, Hikari; Fukuda, Takeshi

    2017-09-05

    An approach similar to the enzyme-linked immunosorbent assay (ELISA), with the advantage of saving time and effort but exhibiting high performance, was developed using orientation-directed half-part antibodies immobilized on CdSe/ZnS quantum dots. ELISA is a widely accepted assay used to detect the presence of a target substance. However, it takes time to quantify the target with specificity and sensitivity owing to signal amplification. In this study, CdSe/ZnS quantum dots are introduced as bright and photobleaching-tolerant fluorescent materials. Since hydrophilic surface coating of quantum dots rendered biocompatibility and functional groups for chemical reactions, the quantum dots were modified with half-sized antibodies after partial reduction. The half-sized antibody could be bound to a quantum dot through a unique thiol site to properly display the recognition domain for the core process of ELISA, which is an antigen-antibody interaction. The reducing conditions were investigated to generate efficient conjugates of quantum dots and half-sized antibodies. This was applied to IL-6 detection, as the quantification of IL-6 is significant owing to its close relationships with various biomedical phenomena that cause different diseases. An ELISA-like assay with CdSe/ZnS quantum dot institution (QLISA; Quantum dot-linked immunosorbent assay) was developed to detect 0.05ng/mL IL-6, which makes it sufficiently sensitive as an immunosorbent assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Fasciola hepatica saposin-like-2 protein based ELISA for the serodiagnosis of chronic human fascioliasis

    Science.gov (United States)

    Figueroa-Santiago, Olgary; Delgado, Bonnibel; Espino, Ana M.

    2011-01-01

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed and evaluated for its diagnostic ability to detect human IgG antibodies against Fasciola hepatica saposin-like protein-2. The assay was compared with an indirect ELISA with excretory-secretory products (FhES) from adult F. hepatica. In an analysis of the sera of 37 patients infected with F. hepatica, 40 patients with other parasitic infections, and 50 healthy controls, the sensitivity of both ELISA assays was 100%. However, the FhSAP2-based ELISA was more specific (95.6%) than the FhES-ELISA (91.9%). These results demonstrated that FhSAP2 can be used in the serodiagnosis of chronic human fascioliasis with additional advantage that is relative cheap and easy to produce. Studies are in progress to evaluate this FhSAP2-ELISA assay in a large-scale prevalence surveys in endemic areas. PMID:21683266

  18. Survey on The Occurrence of Viruses Infecting Cucurbits in Yogyakarta and Central Java

    Directory of Open Access Journals (Sweden)

    Budi Setiadi Daryono

    2009-12-01

    Full Text Available Cucurbits are grown throughout the Java Island as dry season crops. Plants having mosaic, mottling, chlorosis and leaf distortion symptoms were frequently found in most of the cucurbit fields during the survey which conducted in Central Java including Sleman, Kulon Progo, and Klaten during July–September 2000 and 2001. Using double antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA; Cucumber mosaic virus (CMV, Cucumber green mottle mosaic virus (CGMMV and Kyuri green mottle mosaic virus (KGMMV were found infecting cucurbits. CMV was widespread, infecting 48.9% of the samples tested followed by CGMMV (12.8% and KGMMV (6.4%, while others samples (31.9% were not tested, double infections were common with 8.5 % of the samples being infected with two viruses (CGMMV and KGMMV and 34% with three viruses (CMV, CGMMV, and KGMMV. Severe mosaic and mottle symptoms were associated most often with single infection of CGMMV and KGMMV respectively. In addition, these are the first detections of CGMMV and KGMMV infecting cucurbit plants in Indonesia. Tanaman labu-labuan umumnya tumbuh sepanjang musim kemarau diPulau Jawa. Tanaman labu-labuan dengan gejala mosaik, klorosis, mottling dan bentuk daun serta buah yang berubah banyak dijumpai selama survei yang dilakukan di Kulon Progo, Sleman dan Klaten pada bulan Juli sampai September tahun 2000 dan 2001. Deteksi menggunakan metode double antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA telah berhasil mengetahui keberadaan dan infeksiCucumber mosaic virus(CMV,Cucumber green mottle mosaic virus (CGMMV dan Kyuri green mottle mosaic virus (KGMMV pada tanaman labu-labuan di tiga kabupaten tersebut. CMV menginfeksi tanaman labu-labuan tinggi yaitu 48,9% dari jumlah sampel tanaman yang dikoleksi, kemudian CGMMV (12,8% dan KGMMV(6,4%, sedangkan sebanyak 14 sampel tanaman (31,9%tidak dideteksi.Infeksi ganda banyak ditemukan dan 8,5 % sampel tanaman terinfeksi oleh dua jenis virus (CGMMV dan

  19. Development of an ELISA and Immunochromatographic Strip for Highly Sensitive Detection of Microcystin-LR

    Directory of Open Access Journals (Sweden)

    Liqiang Liu

    2014-08-01

    Full Text Available A monoclonal antibody for microcystin–leucine–arginine (MC-LR was produced by cell fusion. The immunogen was synthesized in two steps. First, ovalbumin/ bovine serum albumin was conjugated with 6-acetylthiohexanoic acid using a carbodiimide EDC (1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride/ NHS (N-hydroxysulfosuccinimide reaction. After dialysis, the protein was reacted with MC-LR based on a free radical reaction under basic solution conditions. The protein conjugate was used for immunization based on low volume. The antibodies were identified by indirect competitive (icELISA and were subjected to tap water and lake water analysis. The concentration causing 50% inhibition of binding of MC-LR (IC50 by the competitive indirect ELISA was 0.27 ng/mL. Cross-reactivity to the MC-RR, MC-YR and MC-WR was good. The tap water and lake water matrices had no effect on the detection limit. The analytical recovery of MC-LR in the water samples in the icELISA was 94%–110%. Based on this antibody, an immunochromatographic biosensor was developed with a cut-off value of 1 ng/mL, which could satisfy the requirement of the World Health Organization for MC-LR detection in drinking water. This biosensor could be therefore be used as a fast screening tool in the field detection of MC-LR.

  20. The use of ELISAs for monitoring exposure of pig herds to Brachyspira hyodysenteriae

    Directory of Open Access Journals (Sweden)

    Song Yong

    2012-01-01

    Full Text Available Abstract Background Swine dysentery (SD, a mucohaemorrhagic diarrhoeal disease of pigs, results from infection of the large intestine with the spirochaete Brachyspira hyodysenteriae. ELISA systems using whole spirochaete cells (WC and the B. hyodysenteriae outer membrane lipoprotein Bhlp29.7 previously have been established as potential diagnostic tools for SD. However, their true value in identifying infected herds remains unclear. The present study aimed to compare the performance of whole-cell and Bhlp29.7 based ELISAs in detecting specific immunoglobulin class IgG and IgM to B. hyodysenteriae in growing pigs, and additionally evaluated whether meat juice could serve as a source of specific antibodies. Results Levels of circulating IgG and IgM reacting with WC spirochaete preparations and recombinant Bhlp29.7 peaked 4-6 weeks post-infection in the experimentally challenged pigs, and remained elevated in the present study. In a cohort of pigs on an infected farm levels of antibody directed against both antigens showed a progressive increase with time. However, other than for the level of IgG against WC antigen, a significant increase in antibody levels also was observed in a cohort of pigs on a non-infected farm. In addition, assays using meat juice had 100% specificity and equivalent sensitivity to those based on serum, and likewise the best performance was achieved using the WC IgG ELISA. Conclusions IgG ELISAs using either WC or Bhlp29.7 as plate-coating antigens were shown to be useful for monitoring the dynamics of B. hyodysenteriae infection in grower pigs. Of the two antigens, the WC preparation tended to give better discrimination between pigs from infected and non-infected farms. Testing of meat juice was shown to have potential for identifying infected herds.

  1. Elisa Miller | NREL

    Science.gov (United States)

    Elisa Miller Photo of Elisa Miller Elisa Link-Miller Researcher III-Chemistry Elisa.Miller@nrel.gov | 303-384-6777 Dr. Elisa Miller-Link studies the surface of semiconductors that are applicable for , and other nanocrystalline films. Elisa came to NREL in 2013 as an NREL Director's Fellowship recipient

  2. Incidence of Prunus necrotic ringspot virus in Jordan

    Directory of Open Access Journals (Sweden)

    N. Salem

    2003-12-01

    Full Text Available A survey of Prunus necrotic ringspot virus (PNRSV incidence in Jordan stone-fruit growing areas was conducted during 2000–2002. A total of 2552 samples were collected from 72 commercial orchards, a mother block, 15 nurseries, and a varietal collection. A total of 208 almond, 451 apricot, 149 cherry, 250 nectarine, 1016 peach, and 478 plum trees were tested individually for PNRSV by the double-antibody sandwich enzyme linked immunosorbent assay (DAS-ELISA. Around 15% of tested samples were infected with PNRSV. The virus incidence in almond, nectarine, plum, peach, cherry, and apricot was 24, 16, 16, 14, 13, and 10% of tested trees respectively. The level of viral infection was highest in the mother block (19%, and lowest in the samples from the nurseries (10%.

  3. Influenza A virus H5-specific antibodies in mute swans (Cygnus olor) in the USA.

    Science.gov (United States)

    Kistler, Whitney M; Stallknecht, David E; Lebarbenchon, Camille; Pedersen, Kerri; Marks, David R; Mickley, Randy; DeLiberto, Thomas J; Yabsley, Michael J

    2015-04-01

    The use of serologic assays for influenza A virus (IAV) surveillance in wild birds has increased because of the availability of commercial enzyme-linked immunosorbent assays (ELISAs). Recently, an H5-specific blocking ELISA (bELISA) was shown to reliably detect H5-specific antibodies to low- and high-pathogenic H5 viruses in experimentally infected waterfowl. Mute Swans (Cygnus olor) were frequently associated with highly pathogenic H5N1 outbreaks in Europe and may have a similar role if highly pathogenic H5N1 is introduced into North America. We measured the prevalence of antibodies to the nucleoprotein and H5 protein in Mute Swans using three serologic assays. We collected 340 serum samples from Mute Swans in Michigan, New Jersey, New York, and Rhode Island, US. We detected antibodies to the IAV nucleoprotein in 66.2% (225/340) of the samples. We detected H5-specific antibodies in 62.9% (214/340) and 18.8% (64/340) using a modified H5 bELISA protocol and hemagglutination inhibition (HI) assay, respectively. The modified H5 bELISA protocol detected significantly more positive samples than did the manufacturer's protocol. We also tested 46 samples using virus neutralization. Neutralization results had high agreement with the modified H5 bELISA protocol and detected a higher prevalence than did the HI assay. These results indicate that North American Mute Swans have high nucleoprotein and H5 antibody prevalences.

  4. Anti-Trypanosoma cruzi antibody detection in eastern Andalusia (Spain).

    Science.gov (United States)

    Marín, Clotilde; Concha-Valdez, Fanny; Cañas, Rocío; Gutiérrez-Sánchez, Ramón; Sánchez-Moreno, Manuel

    2014-03-01

    Chagas disease caused by the protozoan haemoflagellate Trypanosoma cruzi is no longer found exclusively in Latin America; the disease is occurring in Europe, and Spain is the country with the highest prevalence. Our aim was to detect anti-T. cruzi antibodies in blood donors from southeast Spain, and we performed eight serological diagnostic assays on each of 550 blood samples collected in March-June 2010. Two in-house ELISA methods were used to test against a parasite lysate (ELISA-H) and the semi-purified superoxide dismutase excreted by T. cruzi (ELISA-SODe); we also used the Western blot technique against the same antigen (WB-SODe), indirect immunofluorescence (IFA) and four commercial tests. The serological test results showed a range of seroprevalence values, the lowest being 1.1%, determined by IFA and two commercial tests (Ab rapid and Chagascreen); other values were: 1.3% (commercial ELISA [Chagas ELISA IgG+IgM]); 2.1% (immunochromatographic test [Stick Chagas]); 2.7% (ELISA-H); 4.0% (WB-SODe); and 4.2%, the highest value (ELISA-SODe). The excellent specificity of SODe antigen for the detection of antibodies to T. cruzi in donors lead us to affirm that the serological test performed with this biomarker could provide a useful screening and confirmatory test method for cases of Chagas disease.

  5. Increased Kappa/Lambda Hybrid Antibody in Serum Is a Novel Biomarker Related to Disease Activity and Inflammation in Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Lang Yi

    2016-01-01

    Full Text Available The κ/λ hybrid antibodies in normal human serum were reported recently, but their clinical relevance has not yet been explored. Rheumatoid arthritis (RA is one of the major joint diseases, and the early diagnosis and treatment of RA remain a challenge. Here, we developed a double-sandwich enzyme-linked immunosorbent assay system to quantify relative serum κ/λ hybrid antibody levels in RA patients, osteoarthritis (OA patients, and healthy controls (HC in order to assess their potential use as a serological biomarker of early disease and clinical activity and to preliminarily investigate their immunomodulatory roles in RA. Surprisingly, we found that κ/λ hybrid antibody was markedly increased in both early and established RA. Serum κ/λ hybrid antibody levels were significantly correlated with clinical indexes and inflammatory markers in RA. Further analysis showed a positive correlation between κ/λ hybrid antibody levels and the 28-joint disease activity score (DAS28. In conclusion, serum κ/λ hybrid antibodies in RA were identified for the first time. High levels of κ/λ hybrid antibody may be a useful tool in distinguishing early RA from OA and HC. We suggest κ/λ hybrid antibody as a marker for disease activity. The increased κ/λ hybrid antibodies were associated with inflammatory conditions in RA.

  6. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay*

    Science.gov (United States)

    DALBY, TINE; SØRENSEN, CHARLOTTE; PETERSEN, JESPER WESTPHAL; KROGFELT, KAREN ANGELIKI

    2010-01-01

    Dalby T, Sørensen C, Petersen JW, Krogfelt KA. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay. APMIS 2010; 118: 968–72. Two types of serological assays are commonly used for the assessment of pertussis vaccine-induced antibodies; the Chinese hamster ovary cell (CHO cell) assay and the immunoglobulin G (IgG) anti pertussis toxin (PT) enzyme-linked immunosorbent assay (IgG anti-PT ELISA). Recently, both the techniques have been modified to improve performance with sera with interfering activity (CHO cell assay) or with heat-treated sera (IgG anti-PT ELISA). These two improved techniques were compared by the analysis of 100 individual serum samples from a previous clinical trial and 213 sera from a longitudinal serum collection from 20 Danish adults recently vaccinated with the Danish acellular pertussis vaccine. The comparison showed a significant linear correlation between the results of the two assays with a p-value of ELISA can be used as a replacement for the often troublesome and time-consuming CHO cell assay for the measurement of vaccine-induced human antibodies to PT. PMID:21091778

  7. The development and applications of polyclonal and monoclonal antibodies for the detection of illicit drugs in saliva samples

    OpenAIRE

    Fanning, Lorna M.

    2002-01-01

    Anti-tetrahydrocannabinol (THC), anti-cocaine and anti-morphine polyclonal antibodies were produced. These antibodies were successfully applied to an ELISA format for the detection of THC, cocaine, and morphine in saliva samples. Monoclonal antibodies against amphetamine and its derivatives were produced using two different conjugates, amphetamine-bovine serum albumin and methamphetaminebovine serum albumin. Two successful clones were produced, and the antibodies were applied to an ELISA ...

  8. Frequency of serum anti-cysticercus antibodies in the population of a rural Brazilian community (Cássia dos Coqueiros, SP determined by ELISA and immunoblotting using Taenia crassiceps antigens

    Directory of Open Access Journals (Sweden)

    BRAGAZZA Lúcia M.

    2002-01-01

    Full Text Available Considering the impact of cysticercosis on public health, especially the neurologic form of the disease, neurocysticercosis (NC, we studied the frequency of positivity of anti-Taenia solium cysticercus antibodies in serum samples from 1,863 inhabitants of Cássia dos Coqueiros, SP, a municipal district located 80 km from Ribeirão Preto, an area considered endemic for cysticercosis. The 1,863 samples were tested by enzyme linked immunosorbent assay (ELISA using an antigenic extract from Taenia crassiceps vesicular fluid (Tcra. The reactive and inconclusive ELISA samples were tested by immunoblotting. Of the 459 samples submitted to immunoblotting, 40 were strongly immunoreactive to the immunodominant 18 and 14 kD peptides. Considering the use of immunoblotting as confirmatory due to its high specificity, the anti-cysticercus serum prevalence in this population was 2.1%.

  9. Detection of Tospoviruses in Ornamental Plants in Hobby Gardens and Landscaping Areas in Adalar District of Istanbul Province

    Directory of Open Access Journals (Sweden)

    Fatma Şafak

    2017-09-01

    Full Text Available This study was conducted in order to detect Tomato spotted wilt virus (TSWV, Irish yellow spot virus (IYSV and Impatients necrotic spot virus (INSV in ornamental plants growing in hobby gardens and landscaping areas in Adalar district (Büyükada, Heybeliada, Kınalıada and Burgazada of Istanbul province between 2015 and 2016. During the surveys carried out in that district, the samples were collected from both simptomatologically suspicious ornamental plants and the plants which did not show any symptoms. All of the collected samples (n=150 were firstly tested by Double Antibody Sandwich (DAS ELISA and none of the samples were found to be infected with TSWV and INSV. The samples detected to be positive with IYSV by ELISA tests were then used in RT-PCR studies. At the RT-PCR using the IYSV-465c; IYSV-239f primer pair, a band with a size of 240 bp was observed for Pittosporum tobira and Hydrangea macrophylla. Therefore, the presence of IYSV infection in Adalar was also confirmed molecularly.

  10. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    Science.gov (United States)

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in

  11. Development of a Blocking ELISA Using a Monoclonal Antibody to a Dominant Epitope in Non-Structural Protein 3A of Foot-and-Mouth Disease Virus, as a Matching Test for a Negative-Marker Vaccine.

    Directory of Open Access Journals (Sweden)

    Yuanfang Fu

    Full Text Available Foot-and-mouth disease (FMD is a devastating animal disease. Strategies for differentiation of infected from vaccinated animals (DIVA remain very important for controlling disease. Development of an epitope-deleted marker vaccine and accompanying diagnostic method will improve the efficiency of DIVA. Here, a monoclonal antibody (Mab was found to recognize a conserved "AEKNPLE" epitope spanning amino acids 109-115 of non-structural protein (NSP 3A of foot-and-mouth disease virus (FMDV; O/Tibet/CHA/99 strain, which could be deleted by a reverse-genetic procedure. In addition, a blocking ELISA was developed based on this Mab against NSP 3A, which could serve as a matching test for a negative-marker vaccine. The criterion of this blocking ELISA was determined by detecting panels of sera from different origins. The serum samples with a percentage inhibition (PI equal or greater than 50% were considered to be from infected animals, and those with <50% PI were considered to be from non-infected animals. This test showed similar performance when compared with other 2 blocking ELISAs based on an anti-NSP 3B Mab. This is the first report of the DIVA test for an NSP antibody based on an Mab against the conserved and predominant "AEKNPLE" epitope in NSP 3A of FMDV.

  12. Measles serodiagnosis: standardization and evaluation of a dot-ELISA Diagnóstico sorológico do sarampo: padronização e avaliação do teste Dot-ELISA

    Directory of Open Access Journals (Sweden)

    Lourdes R. A. Vaz de Lima

    1994-04-01

    Full Text Available A Dot-ELISA using a measles virus (MV antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immuno fluorescence test (IFT were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00. Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85 was higher than that (0.63 of the IgM IFT, although both assays had comparably high (1.00 specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15 of vaccinated children on the 15th day after immunization. In contrast the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.A técnica de Dot-ELISA (DE para detecção de anticorpos IgM e IgG anti vírus do sarampo foi padronizada e avaliada utilizando-se antígeno viral obtido por tratamento com desoxicolato de sódio (DOC. Foram estudadas 192 amostras de soros, compreendendo 47 amostras de 22 pacientes com sarampo nas fases aguda e convalescente, 55 amostras de soros de crianças antes da vacinação, tendo 9 meses de idade, 41 amostras de soros de crianças da mesma idade colhidas após vacinação e 49 amostras de soros de pacientes com outras patologias. O desempenho diagnóstico da técnica de Dot-ELISA-IgG foi semelhante ao de Imunofluorescência indireta (IFI IgG cujos índices de sensibilidade variaram de 0,97 a 1,00 e os de

  13. Development of Immunoassay Based on Monoclonal Antibody Reacted with the Neonicotinoid Insecticides Clothianidin and Dinotefuran

    OpenAIRE

    Uchigashima, Mikiko; Watanabe, Eiki; Ito, Shigekazu; Iwasa, Seiji; Miyake, Shiro

    2012-01-01

    Enzyme-linked immunosorbent assay (ELISA) based on a monoclonal antibody (MoAb) was developed for the neonicotinoid insecticide clothianidin. A new clothianidin hapten (3-[5-(3-methyl-2-nitroguanidinomethyl)-1,3-thiazol-2-ylthio] propionic acid) was synthesized and conjugated to keyhole limpet hemocyanin, and was used for monoclonal antibody preparation. The resulting MoAb CTN-16A3-13 was characterized by a direct competitive ELISA (dc-ELISA). The 50% of inhibition concentration value with cl...

  14. Antibodies and Selection of Monoclonal Antibodies.

    Science.gov (United States)

    Hanack, Katja; Messerschmidt, Katrin; Listek, Martin

    Monoclonal antibodies are universal binding molecules with a high specificity for their target and are indispensable tools in research, diagnostics and therapy. The biotechnological generation of monoclonal antibodies was enabled by the hybridoma technology published in 1975 by Köhler and Milstein. Today monoclonal antibodies are used in a variety of applications as flow cytometry, magnetic cell sorting, immunoassays or therapeutic approaches. First step of the generation process is the immunization of the organism with appropriate antigen. After a positive immune response the spleen cells are isolated and fused with myeloma cells in order to generate stable, long-living antibody-producing cell lines - hybridoma cells. In the subsequent identification step the culture supernatants of all hybridoma cells are screened weekly for the production of the antibody of interest. Hybridoma cells producing the antibody of interest are cloned by limited dilution till a monoclonal hybridoma is found. This is a very time-consuming and laborious process and therefore different selection strategies were developed since 1975 in order to facilitate the generation of monoclonal antibodies. Apart from common automation of pipetting processes and ELISA testing there are some promising approaches to select the right monoclonal antibody very early in the process to reduce time and effort of the generation. In this chapter different selection strategies for antibody-producing hybridoma cells are presented and analysed regarding to their benefits compared to conventional limited dilution technology.

  15. Occurrence of infectious laryngotracheitis outbreaks in commercial layer hens detected by ELISA.

    Science.gov (United States)

    Aras, Zeki; Yavuz, Orhan; Sanioğlu Gölen, Gökçenur

    2018-02-09

    Infectious laryngotracheitis (ILT) is an acute respiratory disease of chickens and a cause of great economic loss in commercial layers. The aims of this study were to investigate the prevalence of ILT in the field outbreaks and to compare the characteristics of ILT-infected and free flocks of commercial layers. A total of 625 blood serum samples were collected from 25 different layer flocks. The presence of antibodies against infectious laryngotracheitis virus (ILTV) in each sample was determined by ELISA. Of the 625 serum samples, 266 (42.56%) were found to be positive for ILTV antibodies. A total of 16 (64%) flocks were detected ILT positive by ELISA method. The mortality of infected flocks was statistically higher (P  0.05) than hens in free flocks. In conclusion, the results of this study indicated a high prevalence of ILT infection in the commercial layer flocks in Konya region, Turkey. In outbreaks, ILT significantly increased the mortality rate and decreased the average live weight in layer hens.

  16. Evaluation of immunoradiometric and ELISA versions of a microtitre plate assay for Bacillus anthracis spores

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A P; Martin, K L; Cross, N L [Chemical Defence Experimental Establishment, Porton (UK); Drake, R G [Glasgow Univ. (UK). Inst. of Biochemistry

    1984-05-11

    Solid-phase indirectly-labelled antibody assays for Bacillus anthracis spores heat-fixed on polystyrene microtitre plates were compared as immunoradiometric assay (IRMA) and enzyme-linked immunosorbent assay (ELISA) versions. Signal-to-noise ratios were usually higher in the IRMA than in the ELISA performed under parallel conditions but replicates were more varied in the IRMA. The antigen detection threshold and resolution limit calculated after regression analysis were broadly comparable in the 2 types of assay.

  17. Characterization of a monoclonal antibody to thymidine glycol monophosphate

    International Nuclear Information System (INIS)

    Chen, B.X.; Hubbard, K.; Ide, H.; Wallace, S.S.; Erlanger, B.F.

    1990-01-01

    A monoclonal antibody specific for thymine glycol (TG) in irradiated or OsO4-treated DNA was obtained by immunizing with thymidine glycol monophosphate (TMP-glycol) conjugated to bovine serum albumin by a carbodiimide procedure. Screening by dot-immunobinding and enzyme-linked immunosorbant assay (ELISA) procedures gave eight clones that bound OsO4- treated DNA. One of them, 2.6F.6B.6C, an IgG2a kappa, was characterized further. Hapten inhibition studies with OsO4-treated DNA showed that the antibody was specific for TMP-glycol. Among the various inhibitors tested, inhibition was in the order TMP-glycol greater than 5,6-dihydrothymidine phosphate greater than TMP greater than thymidine glycol greater than TG. Inhibition by 5,6-dihydrothymidine, thymidine, thymine, AMP, and CMP was negligible. In OsO4-treated DNA, as few as 0.5 TG per 10,000 bp were detectable by direct ELISA. Inhibition assays could detect as few as 1.5 TG per 10,000 bp. The antibody was equally reactive with native or denatured DNA containing TG. Among the X-irradiated homopolymers dC, dA, dG, and dT, only dT reacted with the antibody. Using an ELISA, the antibody could detect damage in irradiated DNA at the level of 20 Gy. Thus the antibody is of potential use in assays for DNA damage caused by X rays or other agents that damage DNA by free radical interactions

  18. Follow-up of neurocysticercosis patients after treatment using an antigen detection ELISA

    Directory of Open Access Journals (Sweden)

    Nguekam

    2003-03-01

    Full Text Available Seven patients with active neurocysticercosis (NCC received an eight days treatment with albendazole and were followed up using computed tomography (CT-scan and a monoclonal antibody based ELISA for the detection of circulating antigen (Ag-ELISA. Only three patients were cured as was shown by CT-scan and by the disappearance of circulating antigens one month after treatment. After a second course of albendazole therapy, two other patients became seronegative. CT-scan showed the disappearance of viable cysts in all persons who became seronegative whereas patients who were not cured remained seropositive. These preliminary results show that this Ag-ELISA is a promising technique for monitoring the success of treatment of NCC patients because of the excellent correlation between the presence of circulating antigens and of viable brain cysts.

  19. Sensitive and specific detection of Crimean-Congo Hemorrhagic Fever Virus (CCHFV)—Specific IgM and IgG antibodies in human sera using recombinant CCHFV nucleoprotein as antigen in μ-capture and IgG immune complex (IC) ELISA tests

    Science.gov (United States)

    Emmerich, Petra; Mika, Angela; von Possel, Ronald; Rackow, Anne; Liu, Yang; Schmitz, Herbert; Sherifi, Kurtesh; Halili, Barie; Jakupi, Xhevat; Berisha, Lindita; Ahmeti, Salih

    2018-01-01

    As the most widespread tick-borne arbovirus causing infections in numerous countries in Asia, Africa and Europe, Crimean-Congo Hemorrhagic Fever Virus (CCHFV, family Nairoviridae) was included in the WHO priority list of emerging pathogens needing urgent Research & Development attention. To ensure preparedness for potential future outbreak scenarios, reliable diagnostic tools for identification of acute cases as well as for performance of seroprevalence studies are necessary. Here, the CCHFV ortholog of the major bunyavirus antigen, the nucleoprotein (NP), was recombinantly expressed in E.coli, purified and directly labeled with horseradish peroxidase (HRP). Employing this antigen, two serological tests, a μ-capture ELISA for the detection of CCHFV-specific IgM antibodies (BLACKBOX CCHFV IgM) and an IgG immune complex (IC) ELISA for the detection of CCHFV-specific IgG antibodies (BLACKBOX CCHFV IgG), were developed. Test performance was evaluated and compared with both in-house gold standard testing by IgM/IgG indirect immunofluorescence (IIF) and commercially available ELISA tests (VectoCrimean-CHF-IgM/IgG, Vector-Best, Russia) using a serum panel comprising paired samples collected in Kosovo during the years 2013–2016 from 15 patients with an acute, RT-PCR-confirmed CCHFV infection, and 12 follow-up sera of the same patients collected approximately one year after having overcome the infection. Reliably detecting IgM antibodies in all acute phase sera collected later than day 4 after onset of symptoms, both IgM ELISAs displayed excellent diagnostic and analytical sensitivity (100%, 95% confidence interval (CI): 85.2%–100.0%). While both IgG ELISAs readily detected the high IgG titers present in convalescent patients approximately one year after having overcome the infection (sensitivity 100%, 95% CI: 73.5%–100.0%), the newly developed BLACKBOX CCHFV IgG ELISA was superior to the commercial IgG ELISA in detecting the rising IgG titers during the acute phase

  20. Development of an indirect enzyme-linked immunosorbent assay (ELISA) to differentiate antibodies against wild-type porcine reproductive and respiratory syndrome from the vaccine strain TJM-F92 based on a recombinant Nsp2 protein.

    Science.gov (United States)

    Wang, X X; Wang, F X; Li, Z G; Wen, Y J; Wang, X; Song, N; Wu, H

    2018-01-01

    An accurate ELISA method to differentiate pigs infected with wild-type porcine reproductive and respiratory syndrome (PRRSV) strains from vaccinated ones would help to monitor PRRSV vaccination compliance. The recombinant protein GST-d120aa derived from the continuous deletion of 120 amino acids in the non-structural protein 2 region of the modified-live vaccine strain TJM-F92 was used to develop an indirect enzyme-linked immunosorbent assay (d120-ELISA) for differentiating serum antibodies against TJM-F92 from other PRRSV strains. At the optimized cut-off value which was calculated at an S/P of 0.25, it yielded a sensitivity of 90.7% and a specificity of 95.1%. Cross-reactivity tests suggested that the d120-ELISA was PRRSV-specific. Coefficient of variations of the repeatability tests ranged between 1.41-17.02%. The results suggest that the d120-ELISA is suitable for differentiating animals infected with wild-type strains from those immunized with MLV TJM-F92. Copyright © 2017. Published by Elsevier B.V.

  1. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    Science.gov (United States)

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  2. Highly sensitive electrochemical immunoassay for human IgG using double-encoded magnetic redox-active nanoparticles

    International Nuclear Information System (INIS)

    Tang, D.; Tang, J.; Su, B.; Chen, H.; Chen, G.; Huang, J.

    2010-01-01

    A new sandwich-type electrochemical immunoassay was developed for the detection of human IgG using doubly-encoded and magnetic redox-active nanoparticles as recognition elements on the surface of a glassy carbon electrode modified with anti-IgG on nanogold particles. The recognition elements were synthesized by coating magnetic Fe3O4 nanoparticles with Prussian blue nanoparticles and then covered with peroxidase-labeled anti-IgG antibodies (POx-anti-IgG) on Prussian blue nanoparticles. The immunoelectrode displays very good electrochemical properties towards detection of IgG via using double-encoded magnetic redox-active nanoparticles as trace and hydrogen peroxide as enzyme substrate. Its limit of detection (10 pmol.L -1 ) is 10-fold better than that of using plain POx-anti-IgG secondary antibodies. The method was applied to the detection of IgG in serum samples, and an excellent correspondence with the reference values was found. (author)

  3. Colony to colorimetry in 6 h: ELISA detection of a surface-expressed Pseudomonas aeruginosa virulence factor using immobilized bacteria.

    Science.gov (United States)

    Adawi, Azmi; Neville, Lewis F

    2012-09-01

    A rapid ELISA employing intact Pseudomonas aeruginosa (PA) is described that allows discrimination between strains harboring flagellin type a or b. All 52 PA strains known to harbor flagellin type b were positive in this ELISA when screened with a fully human monoclonal antibody (LST-007) targeting flagellin type b. Completion of this assay in only 6 h, from picking a single bacterial colony to a colorimetric product, could easily be adapted to a clinical laboratory setting and permit the appropriate choice of therapeutic monoclonal antibody versus its homologous flagellin target in PA-infected patients. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Performance of immunochromatographic and ELISA tests for detecting fallow deer infected with Mycobacterium bovis.

    Science.gov (United States)

    Boadella, M; Barasona, J A; Diaz-Sanchez, S; Lyashchenko, K P; Greenwald, R; Esfandiari, J; Gortazar, C

    2012-04-01

    Fallow deer (Dama dama) are widely distributed as natural or naturalised populations, as well as in game parks and deer farms. We used 157 fallow deer sampled in populations considered to be Mycobacterium tuberculosis complex (MTC) free and 73 Mycobacterium bovis-infected fallow deer confirmed postmortem by culture to evaluate the diagnostic performance of two tests for the detection of anti-mycobacterial antibodies: the dual path platform (DPP) VetTB assay and the bovine purified protein derivative (bPPD) ELISA. We also compared their sensitivity with that of the skin test, analyzed the effect of haemolysis degree on the antibody detection and described the relationship between the test readings and presence/absence of gross tuberculosis (TB) compatible lesions. Sensitivity of bPPD ELISA was 51% at a specificity of 96%. Depending on the cut-off value selected, the sensitivity of DPP VetTB ranged from 62 to 71%, while its specificity was 88-95%. In the subgroup of M. bovis-infected deer for which the skin test data were available (33 of 73); this method detected 76% of culture-positive animals, although the specificity of the intradermal test was not determined in this study. When the DPP VetTB and skin test data were combined, the resulting sensitivity obtained in this sub-group of M. bovis-infected deer increased to 97%. Gross pathology identified TB compatible lesions (TBL) in 89% culture-confirmed fallow deer. The infected animals with visible lesions had significantly higher readings in the DPP VetTB, but not in the bPPD ELISA. Only high levels of haemolysis decreased antibody test sensitivity and this effect was more evident for the bPPD ELISA. The results allowed inferring a number of management recommendations for rapid detection of MTC infection in live fallow deer and in surveys on hunter-harvested cervids. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. ELISA indireto para detecção de IgG antivírus da doença de Newcastle em soro de codorna Indirect ELISA for the detection of IgG specific to Newcastle disease virus in quail serum

    Directory of Open Access Journals (Sweden)

    D.D. Oliveira

    2007-10-01

    Full Text Available An indirect ELISA for the detection of japanese quail IgG specific to Newcastle disease virus (NDV was developed. The secondary anti-quail IgG was produced in Balb/c mice, by inoculating Freund's complete adjuvant emulsified japanese quail-IgG extract. The purification of IgG was achieved using the caprilic acid method. The ELISA was compared to the haemagglutination-inhibition (HI test for antibodies to NDV. ELISA cut-off point was established through TG-ROC analysis. Total correlation was observed between the ELISA and the HI, being the ELISA efficient in the identification of positive and negative sera, with high sensitivity and specificity (100%. These results validate the use of the indirect ELISA as an alternative for the detection of NDV-specific IgG in japanese quail sera, with the advantage of high sensitivity and automation.

  6. Single-dilution enzyme-linked immunosorbent assay for quantification of antigen-specific salmonid antibody

    Science.gov (United States)

    Alcorn, S.W.; Pascho, R.J.

    2000-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.

  7. Highly sensitive and specific determination of mercury(II) ion in water, food and cosmetic samples with an ELISA based on a novel monoclonal antibody

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuzhen; Li, Yuan [Sichuan University, College of Chemistry, Chengdu (China); Yang, Hong [Soochow University, College of Pharmacy, Suzhou (China); Pschenitza, Michael; Niessner, Reinhard; Knopp, Dietmar [Technical University Munich, Chair for Analytical Chemistry, Institute of Hydrochemistry and Chemical Balneology, Munich (Germany); Deng, Anping [Sichuan University, College of Chemistry, Chengdu (China); Soochow University, College of Chemistry, Chemical Engineering and Materials Science, Suzhou (China)

    2012-07-15

    Mercury is one of the most toxic heavy metals present in the environment. In this study, a highly sensitive and specific monoclonal antibody (mAb)-based indirect competitive enzyme-linked immunosorbent assay (ELISA) for the determination of Hg{sup 2+} was developed. A new bifunctional ligand, 6-mercaptonicotinic acid (MNA), which contains a pyridine ring bearing a carboxylic group and a mercapto group, was selected for the preparation of immunogen. After immunization of mice and performing the hybridoma technique, the obtained mAb was characterized for its binding affinity and selectivity for Hg{sup 2+}. Based on this novel mAb, an ELISA was established. At optimal experimental conditions, the standard curve of the ELISA for Hg{sup 2+} was constructed in concentration range of 0.1-100 ng mL{sup -1}. The values of IC{sub 50} and LOD of the assay were found to be 1.12 and 0.08 ng mL{sup -1}. The cross-reactivity was lower than 2 % with MNA, CH{sub 3}Hg, and CH{sub 3}Hg-MNA and was 11.5 % and 4.4 % for Hg{sup +} and Au{sup 3+}, respectively. No cross-reactivity was found with other metal ions such as Cu{sup 2+}, Sn{sup 2+}, Ni{sup 2+}, Mn{sup 2+}, Pb{sup 2+}, Zn{sup 2+}, Cd{sup 2+}, Fe{sup 2+}, Co{sup 2+}, Mg{sup 2+}, Ca{sup 2+}, and anions such as Cl{sup -}, NO{sub 3} {sup -}, NO{sub 2} {sup -}, HCO{sub 3} {sup -}, F{sup -}, and SO{sub 4} {sup 2-}, indicating that the assay displays not only high sensitivity but also high selectivity. Different kinds of samples including water, milk, green vegetable, kelp, facial cleanser, and night cream were spiked with Hg{sup 2+} and the extracts were analyzed by ELISA. Acceptable recovery rates of 80.0-113.0 % and coefficients of variation of 1.9-18.6 % were obtained. A linear relationship between ELISA and cold-vapor atomic fluorescence spectroscopy (CV-AFS) as indicated by a correlation coefficient of 0.97 for liquid samples (water samples) and 0.98 for other samples was obtained. The proposed mAb-based ELISA provides a

  8. Anti-signal recognition particle autoantibody ELISA validation and clinical associations.

    Science.gov (United States)

    Aggarwal, Rohit; Oddis, Chester V; Goudeau, Danielle; Fertig, Noreen; Metes, Ilinca; Stephens, Chad; Qi, Zengbiao; Koontz, Diane; Levesque, Marc C

    2015-07-01

    The aim of this study was to develop and validate a quantitative anti-signal recognition particle (SRP) autoantibody serum ELISA in patients with myositis and longitudinal association with myositis disease activity. We developed a serum ELISA using recombinant purified full-length human SRP coated on ELISA plates and a secondary antibody that bound human IgG to detect anti-SRP binding. Protein immunoprecipitation was used as the gold standard for the presence of anti-SRP. Serum samples from three groups were analysed: SRP(+) myositis subjects by immunoprecipitation, SRP(-) myositis subjects by immunoprecipitation and non-myositis controls. The ELISA's sensitivity, specificity, positive predictive value and negative predictive value were evaluated. Percentage agreement and test-retest reliability were assessed. Serial samples from seven SRP immunoprecipitation-positive subjects were also tested, along with serum muscle enzymes and manual muscle testing. Using immunoprecipitation, we identified 26 SRP(+) myositis patients and 77 SRP(-) controls (including 38 patients with necrotizing myopathy). Non-myositis control patients included SLE (n = 4) and SSc (n = 7) patients. Anti-SRP positivity by ELISA showed strong agreement (97.1%) with immunoprecipitation (κ = 0.94). The sensitivity, specificity, positive predictive value, and negative predictive value of the anti-SRP ELISA were 88, 100, 100 and 96, respectively. The area under the curve was 0.94, and test-retest reliability was strong (r = 0.91, P < 0.001). Serial samples showed that anti-SRP levels paralleled changes in muscle enzymes and manual muscle testing. We developed a quantitative ELISA for detecting serum anti-SRP autoantibodies and validated the assay in myositis. Longitudinal assessment of SRP levels by ELISA may be a useful biomarker for disease activity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions

  9. Mapping of monoclonal antibody- and receptor-binding domains on human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) using a surface plasmon resonance-based biosensor.

    Science.gov (United States)

    Laricchia-Robbio, L; Liedberg, B; Platou-Vikinge, T; Rovero, P; Beffy, P; Revoltella, R P

    1996-10-01

    An automated surface plasmon resonance (SPR)-based biosensor system has been used for mapping antibody and receptor-binding regions on the recombinant human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) molecule. A rabbit antimouse IgG1-Fc antibody (RAM.Fc) was coupled to an extended carboxymethylated-hydrogel matrix attached to a gold surface in order to capture an anti-rhGM-CSF monoclonal antibody (MAb) injected over the sensing layer. rhGM-CSF was subsequently injected and allowed to bind to this antibody. Multisite binding assays were then performed, by flowing sequentially other antibodies and peptides over the surface, and the capacity of the latter to interact with the entrapped rhGM-CSF in a multimolecular complex was monitored in real time with SPR. Eleven MAb (all IgG1K), were analyzed: respectively, four antipeptide MAb raised against three distinct epitopes of the cytokine (two clones against residues 14-24, that includes part of the first alpha-helix toward the N-terminal region; one clone against peptide 30-41, an intrahelical loop; and one clone against residues 79-91, including part of the third alpha-helix) and seven antiprotein MAbs raised against the entire rhGM-CSF, whose target native epitopes are still undetermined. In addition, the binding capacity to rhGM-CSF of a synthetic peptide, corresponding to residues 238-254 of the extracellular human GM-CSF receptor alpha-chain, endowed with rhGM-CSF binding activity, was tested. The results from experiments performed with the biosensor were compared with those obtained by a sandwich enzyme-linked immunosorbent assay (ELISA), using the same reagents. The features of the biosensor technology (fully automated, measure in real time, sharpened yes/no response, less background disturbances, no need for washing step or labeling of the reagent) offered several advantages in these studies of MAb immunoreactivity and epitope mapping, giving a much better resolution and enabling more distinct

  10. Evaluation of a serological test (indirect ELISA) for the diagnosis of sarcoptic mange in red foxes (Vulpes vulpes).

    Science.gov (United States)

    Bornstein, Set; Frössling, Jenny; Näslund, Katarina; Zakrisson, Göran; Mörner, Torsten

    2006-12-01

    Sarcoptic mange occurs in many parts of the world and is common in populations of domestic and wild canids, including red foxes (Vulpes vulpes). In recent years, an indirect antibody enzyme-linked immunosorbent assay (ELISA), with higher sensitivity and specificity than traditional diagnostic methods, has been successfully applied in the diagnosis of sarcoptic mange in dogs. The same ELISA has also demonstrated specific antibodies to Sarcoptes scabiei in experimentally infected red foxes. The aim of this study was to evaluate the indirect ELISA when used to detect antibodies to S. scabiei in field sera from Swedish red foxes. One cohort of both infected and non-infected red foxes (cohort 1; n = 88), and one cohort of apparently non-infected foxes (cohort 2; n = 67) were examined for skin lesions and presence of S. scabiei by thorough visual examination at autopsy and skin scrapings. Samples of blood-tinted body liquid from the abdomen or thorax cavity were collected and analysed by the indirect ELISA. The relative sensitivity and specificity of the ELISA at different cut-offs (OD values) were estimated by comparing the test results to the infection status as determined by examination and skin scrapings. The highest combination of relative sensitivity and specificity, calculated based on cohort 1, was 95.4 and 100.0%, respectively. These estimates were constant for cut-offs 0.150-0.225, which included the cut-off based on the mean plus three standard deviations of test results from cohort 2 (0.165). It is concluded that this test can be useful in diagnosis and epidemiological studies of S. scabiei infection in red foxes.

  11. PM1-Alpha ELISA: the assay of choice for the detection of anti-PM/Scl autoantibodies?

    Science.gov (United States)

    Mahler, Michael; Fritzler, Marvin J

    2009-03-01

    A characteristic serological feature of patients suffering from the overlap polymyositis and scleroderma (PM/Scl) syndrome are antibodies to the human counterpart of the yeast exosome referred to as the PM/Scl complex. Historically, the detection of anti-PM/Scl antibodies was laborious and relied largely on indirect immunofluorescence and immunodiffusion techniques. In 1992 the major autoantigen PM/Scl-100 was identified and cloned. Subsequently, the major epitopes were mapped and one of these, termed PM1-Alpha, became the antigen for a novel ELISA exhibiting high sensitivity and specificity for the detection of anti-PM/Scl antibodies. Comparative studies with other methods using other PM/Scl autoantigens have shown that the PM1-Alpha ELISA has higher sensitivity and specificity than assays that employed recombinant PM/Scl-75c and PM/Scl-100. Anti-PM1-Alpha antibodies were identified in 55.0% of sera from PM/Scl overlap syndrome patients, but were also seen in 7.9% of SSc and in 7.5% of PM patients. The frequency in other systemic autoimmune diseases and in infectious diseases was significant lower. In summary, the data derived from individual studies suggest that PM1-Alpha may become the "gold standard" for the detection of anti-PM/Scl antibodies.

  12. Comparative evaluation of competitive ELISA test in Colombian cattle

    International Nuclear Information System (INIS)

    Marino, O.; Rueda, E.; Sedano, L.; Zuniga, I.; Calderon, C.; Ortega, A.; Puentes, A.

    1998-01-01

    In order to contribute to the definition of the best ELISA test for screening and differential diagnosis of Brucella abortus to be applied for control programmes, a total of 2971 sera from Colombian cattle were tested for brucellosis. Conventional agglutination tests, Buffered Plate antigen test (BPAT) and Rose Bengal (RB) as well as Complement Fixation test (CFT) (Alton, et al. 1988) were used comparatively. Radial immunodiffusion test (RID) was also performed to all sera. The sera were also tested using four different ELISAs: indirect ELISA from FAO/IAEA and the indirect ELISA modified by Nielsen, et al. 1992 as well as two competitive ELISAs: one competitive ELISA used B. abortus O-polysaccharide antigen and an enzyme conjugated monoclonal to the O-polysaccharide for competition and detection. The second competitive ELISA used lipopolysaccharide (sLPS) antigen, a different monoclonal antibody for competition but also specific for the O-polysaccharide and a commercially available goat anti-mouse IgG enzyme conjugate for detection. The sera were analyzed based on its population status, 987 positive obtained from Brucella abortus infected herds based on clinical and/or bacteriological evidence and a high prevalence of brucellosis, CFT percentage of positive animals in the herd was greater than 5%. Eight hundred sixty six (866) negative sera from non-vaccinated cattle from a brucellosis free area and 1118 negative sera obtained from reglamentary vaccinated areas under a free herd program. Initial cut-off values were derived using negative serum samples. The diagnostic sensitivity and specificity was defined from frequency histograms based on this cut-off values and using 2x2 tables, corresponding confidence limits (95%) were calculated. The data were also analysed using signal detection analysis (ROC). Kappa statistics was determined for all tests and populations, accuracy was used as index of comparison to evaluate different assays. The data support the initial

  13. Homogeneous immunoassay for the cancer marker alpha-fetoprotein using single wavelength excitation fluorescence cross-correlation spectroscopy and CdSe/ZnS quantum dots and fluorescent dyes as labels

    International Nuclear Information System (INIS)

    Wang, Jinjie; Liu, Heng; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    The article describes sensitive and selective homogeneous immunoassays for the liver cancer biomarker alpha-fetoprotein (AFP) in human serum by using single wavelength excitation fluorescence cross-correlation spectroscopy (SW-FCCS). Both competitive and sandwich immunoassay modes were applied, and AFP served as a model analyte. Fluorescent CdSe/ZnS quantum dots (with a 655 nm emission peak) and the fluorophore Alexa Fluor 488 (520 nm emission) were chosen to label the antibodies in the sandwich mode, and the antibody and the antigen in the competitive mode. Under optimized conditions, the sandwich assay has a linear dynamic range that covers the 20 pM to 5.0 nM concentration range. The competitive assay, in turn, extends from 180 pM to 15.0 nM. The respective detection limits are 20 pM and 180 pM. The method was successfully applied to directly determine AFP in (spiked) clinical samples, and results were in good agreement with data obtained via ELISAs. (author)

  14. Application of the antigen ELISA for monitoring the effectiveness of the tsetse and trypanosomosis control campaign in Zambia

    Energy Technology Data Exchange (ETDEWEB)

    Sinyangwe, L N; Munyama, G M; Mubanga, J [Central Veterinary Research Inst. (CVRI), Lusaka (Zambia)

    1997-02-01

    Antibody and antigen-detection ELISA were used to screen sera originating from a tsetse free area. In addition, bovine samples from tsetse infested areas were analysed using the Buffy Coat Technique (BCT) and the antigen ELISA. Few samples from a negative control population were detected positive resulting in a very good specificity for both tests. When screening a trypanosome infected population the BCT detected more acute and the Ag-ELISA more chronic infections. In conclusion, the antigen ELISA should be used in combination with the BCT, especially in geographical areas where the BCT does not detect any patent infections. (author). 2 refs, 4 figs, 4 tabs.

  15. Application of the antigen ELISA for monitoring the effectiveness of the tsetse and trypanosomosis control campaign in Zambia

    International Nuclear Information System (INIS)

    Sinyangwe, L.N.; Munyama, G.M.; Mubanga, J.

    1997-01-01

    Antibody and antigen-detection ELISA were used to screen sera originating from a tsetse free area. In addition, bovine samples from tsetse infested areas were analysed using the Buffy Coat Technique (BCT) and the antigen ELISA. Few samples from a negative control population were detected positive resulting in a very good specificity for both tests. When screening a trypanosome infected population the BCT detected more acute and the Ag-ELISA more chronic infections. In conclusion, the antigen ELISA should be used in combination with the BCT, especially in geographical areas where the BCT does not detect any patent infections. (author). 2 refs, 4 figs, 4 tabs

  16. In vivo collection of rare proteins using kinesin-based "nano-harvesters".

    Energy Technology Data Exchange (ETDEWEB)

    Bachand, Marlene; Bachand, George David; Greene, Adrienne Celeste; Carroll-Portillo, Amanda

    2008-11-01

    In this project, we have developed a novel platform for capturing, transport, and separating target analytes using the work harnessed from biomolecular transport systems. Nanoharvesters were constructed by co-organizing kinesin motor proteins and antibodies on a nanocrystal quantum dot (nQD) scaffold. Attachment of kinesin and antibodies to the nQD was achieved through biotin-streptavidin non-covalent bonds. Assembly of the nanoharvesters was characterized using a modified enzyme-linked immunosorbent assay (ELISA) that confirmed attachment of both proteins. Nanoharvesters selective against tumor necrosis factor-{alpha} (TNF-{alpha}) and nuclear transcription factor-{kappa}B (NF-{kappa}B) were capable of detecting target antigens at <100 ng/mL in ELISAs. A motility-based assay was subsequently developed using an antibody-sandwich approach in which the target antigen (TNF-{alpha}) formed a sandwich with the red-emitting nanoharvester and green-emitting detection nQD. In this format, successful sandwich formation resulted in a yellow emission associated with surface-bound microtubules. Step-wise analysis of sandwich formation suggested that the motility function of the kinesin motors was not adversely affected by either antigen capture or the subsequent binding of the detection nQDs. TNF-{alpha} was detected as low as {approx}1.5 ng/mL TNF-{alpha}, with 5.2% of the nanoharvesters successfully capturing the target analyte and detection nQDs. Overall, these results demonstrate the ability to capture target protein analytes in vitro using the kinesin-based nanoharvesters in nanofluidic environments. This system has direct relevance for lab-on-a-chip applications where pressure-driven or electrokinetic movement of fluids is impractical, and offers potential application for in vivo capture of rare proteins within the cytoplasmic domain of live cells.

  17. Comparing validation of four ELISA-systems for detection of Salmonella derby- and Salmonella infantis-infected pigs.

    Science.gov (United States)

    Roesler, Uwe; Szabo, Istvan; Matthies, Claudia; Albrecht, Kerstin; Leffler, Martin; Scherer, Kathrin; Nöckler, Karsten; Lehmann, Jörg; Methner, Ulrich; Hensel, Andreas; Truyen, Uwe

    2011-01-01

    The objective of this study was the comparative evaluation of four indirect Salmonella ELISA tests at study time approved in Germany to detect Salmonella infection in pigs.Three tests are based on a LPS-antigen mix and directed against specific IgG antibodies. The fourth test is based on a purified S. Typhimurium whole-cell lysate antigen and discriminates between Salmonella-specific IgM-, IgA-, and IgG- antibodies. In a longitudinal study, two groups of six weeks old hybrid piglets were orally infected with a porcine S. Infantis or S. Derby strain. Clinical and bacteriological parameters were monitored weekly during an observation period of 130 days after infection and serum samples were investigated in parallel with the respective ELISAs. Apparently, the LPS-based ELISA systems used in this study failed to recognize S. Infantis-infected pigs although those animals shed the pathogen in high amounts throughout the study until day 81 post infection (p. i.). In contrast, the isotype-specific Salmonella Typhimurium whole-cell-lysate based ELISA was capable of detecting Salmonella-infected pigs from day ten p. i. at all tested serotypes and revealed the highest sensitivity in detection of S. Infantis-infected pigs. Furthermore, it became apparent that the often used surveillance cut-off value of 40 OD% is not appropriate for intra-vitam detection of S. Infantis- and S. Derby-infected pigs. In contrast, the cut-off values of the ELISAs given by the suppliers result in considerable higher detection rates.

  18. Characteristics of enzyme-linked immunosorbent assay for detection of IgG antibodies specific to Сhlamydia trachomatis heat shock protein (HSP-60

    Directory of Open Access Journals (Sweden)

    O. Yu. Galkin

    2017-02-01

    Full Text Available The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system. The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered. In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.

  19. Biomimetic ELISA detection of malachite green based on magnetic molecularly imprinted polymers.

    Science.gov (United States)

    Li, Lu; Lin, Zheng-Zhong; Peng, Ai-Hong; Zhong, Hui-Ping; Chen, Xiao-Mei; Huang, Zhi-Yong

    2016-11-01

    A direct competitive enzyme-linked immunosorbent assay (ELISA) method was used for the detection of malachite green (MG) with a high sensitivity and selectivity using magnetic molecularly imprinted polymers (MMIPs) as a bionic antibody. MMIPs were prepared through emulsion polymerization using Fe 3 O 4 nanoparticles as magnetic nuclei, MG as a template, methacrylic acid (MAA) as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a crosslinking agent and span-80/tween-80 as mixed emulsifiers. The MMIPs were characterized by scanning electron micrographs (SEM), thermal-gravimetric analyzer (TGA), Fourier transform infrared spectrometer (FT-IR) and vibrating sample magnetometer (VSM), respectively. A high magnetic saturation value of 54.1emug -1 was obtained, resulting in rapid magnetic separation of MMIPs with an external magnet. The IC 50 of the established ELISA method was 20.1μgL -1 and the detection limit (based on IC 85 ) was 0.1μgL -1 . The MMIPs exhibited high selective binding capacity for MG with cross-reactivities less than 3.9% for MG structural analogues. The MG spiking recoveries were 85.0%-106% with the relative standard deviations less than 4.7%. The results showed that the biomimetic ELISA method by using MMIPs as bionic antibody could be used to detect MG rapidly in fish samples with a high sensitivity and accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Accurate antemortem diagnosis of equine protozoal myeloencephalitis (EPM) based on detecting intrathecal antibodies against Sarcocystis neurona using the SnSAG2 and SnSAG4/3 ELISAs.

    Science.gov (United States)

    Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M

    2013-01-01

    Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  1. Refining the LPS-Antigen in Salmonella Antibody Elisa for Poultry Enhanced Specificity without Impairing Sensitivity

    DEFF Research Database (Denmark)

    Lauritsen, Klara Tølbøl; Lind, Peter; Klausen, Joan

    2014-01-01

    In the Danish serological surveillance for Salmonella in poultry (serum and egg yolk) a mix-ELISA is used, based on S. typhimurium and S. enteritidis antigens (Feld et al., 2000). When we evaluated results of the test retrospectively, over the years an unacceptably large fraction of seropositive...... findings could not be confirmed by the subsequent confirmatory bacteriological sampling in the herd. Therefore we tried to enhance specificity of the ELISA, without losing sensitivity, by refining the antigens used....

  2. A novel assay for detecting antibodies to cytochrome P4502D6, the molecular target of liver kidney microsomal antibody type 1.

    Science.gov (United States)

    Kerkar, N; Ma, Y; Hussain, M; Muratori, L; Targett, C; Williams, R; Bianchi, F B; Mieli-Vergani, G; Vergani, D

    1999-03-04

    Liver Kidney Microsomal type 1 (LKM1) antibody, the diagnostic marker of autoimmune hepatitis type 2, is also found in a proportion of patients with hepatitis C virus infection (HCV). It is detected conventionally by the subjective immunofluorescence technique. Our aim was to establish a simple and objective enzyme-linked immunosorbent assay (ELISA) that measures antibodies to cytochrome P4502D6 (CYP2D6), the target of LKM1. An indirect ELISA using eukaryotically expressed CYP2D6 was designed. Absorbance values obtained against a reference microsomal preparation were subtracted from those obtained against a microsomal preparation over-expressing CYP2D6, thus removing the non-CYP2D6-specific reaction. Sera from 51 LKM1 positive patients (21 autoimmune hepatitis and 30 with HCV infection), 111 LKM1 negative patients with chronic liver disease (including 20 with HCV infection) and 43 healthy controls were tested. Of 51 patients positive by immunofluorescence, 48 were also positive by ELISA while all the 154 LKM1 negative subjects were also negative by ELISA. There was a high degree of association between IFL and ELISA as demonstrated by a kappa reliability value of 0.96. The absorbance values by ELISA correlated with immunofluorescence LKM1 titres both in autoimmune hepatitis (r = 0.74, p < 0.001) and HCV infection (r = 0.67, p < 0.001). The simple, objective ELISA described has the potential to replace the standard immunofluorescence technique.

  3. Enzyme-linked immunosorbent assays for insulin-like growth factor-I using six-histidine tag fused proteins

    International Nuclear Information System (INIS)

    Huang Yong; Shi Ruina; Zhong Xuefei; Wang Dan; Zhao Meiping; Li Yuanzong

    2007-01-01

    The fusion proteins of insulin-like growth factor-I (IGF-I) and six-histidine tag (IGF-I-6H, 6H-IGF-I-6H) were cloned, expressed, purified and renatured, with their immunoreaction properties and biological activities intact. The binding kinetics between these fusion proteins and anti-IGF-I antibody or anti-6H antibody were studied using surface plasmon resonance (SPR). Two enzyme-linked immunosorbent assay (ELISA) modes, which proved feasible in the measurement of human serum samples, were used to detect IGF-I with the help of the six-histidine tagged proteins. Furthermore, combining the production technique of the six-histidine tagged fusion protein with the competitive sandwich ELISA mode, using an enzyme labeled anti-6H antibody as a tracer, can be a universal immunochemical method to quantitate other polypeptides or proteins

  4. Production and characterization of monoclonal antibodies specific to the strobilurin pesticide pyraclostrobin.

    Science.gov (United States)

    Mercader, Josep V; Suárez-Pantaleón, Celia; Agulló, Consuelo; Abad-Somovilla, Antonio; Abad-Fuentes, Antonio

    2008-09-10

    Strobilurin fungicides are nowadays among the most important fungicides in the market of active agrochemicals. Pyraclostrobin, which belongs to the last generation of this family of molecules, shows a broader antifungal activity spectrum and higher efficiency and security profiles than previous fungicides. This paper describes the synthesis of functionalized haptens, the production of monoclonal antibodies, and the development of enzyme-linked immunosorbent assays (ELISA) for the detection of pyraclostrobin. A conformational analysis of hapten structure was performed, which provided relevant data concerning the length of the spacer arm. A very useful strategy has been followed for the screening of hybridomas, leading to the selection of a panel of high-affinity monoclonal antibodies to pyraclostrobin. Moreover, different immunoassays have been characterized using the conjugate-coated indirect ELISA format, and limits of detection below 0.1 microg/L have been obtained. Also, a simplified one-step procedure has been carried out with two indirect assays. Finally, these results have been compared with the performance of the same antibodies in the antibody-coated direct ELISA format.

  5. Immune response to pneumococcal polysaccharides 4 and 14 in elderly and young adults. I Antibody concentrations, avidity and functional activity

    Directory of Open Access Journals (Sweden)

    Carlone George M

    2005-06-01

    Full Text Available Abstract Streptococcus pneumoniae is a serious worldwide pathogen and the focus of numerous vaccine development projects. Currently the most widely accepted surrogate marker for evaluating the efficacy of a given vaccine is to utilize ELISA. Measurement of antibody concentration by ELISA without reduction in cross-reactive antibodies causes an overestimation of antibody concentration and therefore protection, this is most notable in the aged, an at risk group for this infection. We compared the immune response to the pneumococcal polysaccharides (PPS 4 and 14 of 20 young to 20 elderly adults. Pre-and post-vaccination IgG antibody concentrations and antibody avidity against PPS4 and PPS14 were measured using two different enzyme-linked immunosorbant assay (ELISA absorption protocols. All sera were pre-absorbed with either cell-wall polysaccharide (CPS, or CPS and serotype 22F polysaccharide. Pre- and post-vaccination IgG antibody concentrations for serotype 4, but not 14, were significantly lowered with the additional absorption with serotype 22F polysaccharide in both age groups. Young and elderly demonstrated a significant increase from pre- to post-immunization antibody concentration, using either absorption method; and opsonophagocytic antibody titers in response to both PPS4 and PPS14. The correlation coefficients between ELISA and opsonophagocytic assays were improved by additional absorption with serotype 22F in response to serotype 4, but not serotype 14 in all age groups. Opsonophagocytic antibody titers in a sub-group of elderly (>77 years of age were significantly lower than the opsonophagocytic antibody concentrations in young adults. These results suggest the importance of eliminating cross-reactive antibodies from ELISA measurements by absorption of serum and an age-related impairment in the antibody response to pneumococcal polysaccharides.

  6. Developments of sensitive immunoassays for detection of antibodies against hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu-Matiu, I; Sanchez, Y; Dreesman, G R [Baylor Univ., Houston, TX (USA). Coll. of Medicine; Fields, H A [Centers for Disease Control, Public Health Service, Department of Health and Human Services, Phoenix, AZ (USA)

    1983-01-01

    Three micro solid phase immunoassays (a micro-SPRIA and two ELISA techniques) were developed and tested for the detection of anti-HBs antibodies. Two different crosslinkers (glutaraldehyde and N-succinimidyl 3-(2-pyridyldithio) propionate) were used to couple a goat anti-mouse IgG reagent to alkaline phosphatase for use as enzyme-labeled probes in the two ELISA tests. With the latter cross-linker, a defined conjugate with a 1 : 1 antibody-enzyme molar ratio was obtained. The sensitivities of micro-SPRIA and the two types of ELISA were compared to that of the commercial solid phase radioimmunoassay AUSAB test. All three microtests were significantly more sensitive than the AUSAB test. The ELISA using the glutaraldehyde cross-linked conjugate was 3-5 times less sensitive than micro-SPRIA, while the ELISA using the disulfide-linked conjugate was 2.6-4.0 times more sensitive than micro-SPRIA.

  7. Significance of Serology by Multi-Antigen ELISA for Tissue Helminthiases in Korea

    Science.gov (United States)

    2017-01-01

    It is clinically important to differentiate tissue-invading helminthiasis. The purpose of this study was to assess the specific immunoglobulin G (IgG) antibody positive rates for clonorchiasis, paragonimiasis, cysticercosis, and sparganosis 4 helminthiases from 1996 to 2006 using multi-antigen enzyme-linked immunosorbent assay (ELISA) in Korea. Results of 6,017 samples, which were referred to our institute for serodiagnosis, were analyzed. The subjects with positive serum IgG antibodies were 1,502 (25.0%) for any of the 4 helminthiases. The overall positive numbers for clonorchiasis, paragonimiasis, cysticercosis, and sparganosis were 728 (12.1%), 166 (2.8%), 729 (12.1%), and 263 (4.4%), respectively. The positive serologic reaction to multi-antigens was determined in 309 (20.6%) of the 1,502 total seropositive subjects. Those with multi-antigen positivity were regarded as positive for the antigen of strongest reaction but cross-reaction to others with weak positive reaction. Annual seropositive rates for those 4 tissue helminthiases ranged from 12.1% to 35.7%. The highest rate was observed in age from 60 to 69 years old and prevalence of men (27.4%; 1,030/3,763) was significantly higher than of women (19.1%; 332/1,741). Hospital records of 165 ELISA positive patients were reviewed to confirm correlation with their clinical diagnosis. Paragonimiasis was highly correlated as 81.8% (9/11), cysticercosis 29.9% (20/67), clonorchiasis 29.0% (20/69), and sparganosis 11.1% (2/18). In conclusion, the multi-antigen ELISA using 4 helminth antigens is useful to differentiate suspected tissue-invading helminthiases, especially ELISA diagnosis of paragonimiasis is reliable. The seropositivity is still high among suspected patients in Korea. PMID:28581268

  8. Seroprevalence of infectious bursal disease virus antibodies in ...

    African Journals Online (AJOL)

    This study was aimed at determining the antibodies of IBDV in some poultry species in Maiduguri, Nigeria. A total of 944 serum samples were collected from village chickens, broilers, layers, ducks, turkeys and geese in Maiduguri and tested for IBDV antibodies using inzyme linked Immunosorbent assay (ELISA) and a ...

  9. A sensitive monoclonal antibody-based enzyme-linked immunosorbent assay for chlorpyrifos residue determination in Chinese agricultural smaples

    Science.gov (United States)

    A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC50 and IC10 of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries recovery rate...

  10. Synthesis and charge storage properties of double-layered NiSi nanocrystals

    International Nuclear Information System (INIS)

    Yoon, Jong-Hwan

    2010-01-01

    Based on bidirectional diffusion of Ni atoms, double-layered nickel silicide (NiSi) nanocrystals (NCs) for multilevel charge storage were fabricated, and their charge storage properties were examined. The double layer was produced by long-term thermal annealing (for 4 h at 900 o C) of a sandwich structure comprised of a thin Ni film of 0.3 nm sandwiched between two silicon-rich oxide (SiO 1.36 ) layers. Transmission electron microscopic image clearly exhibits a distinct NiSi nanocrystal double layer with a gap of about 7 nm between the mean positions of particle distribution in each NC layer. Capacitance-voltage measurements on the metal/oxide/semiconductor (MOS) capacitors with the double-layered NiSi nanocrystals are shown to have the apparent two plateaus of charge storage, the large memory window of about 9 V and the improved charge retention stability.

  11. Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays.

    Science.gov (United States)

    Chan, Conrad E Z; Chan, Annie H Y; Lim, Angeline P C; Hanson, Brendon J

    2011-10-28

    Rapid development of diagnostic immunoassays against novel emerging or genetically modified pathogens in an emergency situation is dependent on the timely isolation of specific antibodies. Non-immune antibody phage display libraries are an efficient in vitro method for selecting monoclonal antibodies and hence ideal in these circumstances. Such libraries can be constructed from a variety of sources e.g. B cell cDNA or synthetically generated, and use a variety of antibody formats, typically scFv or Fab. However, antibody source and format can impact on the quality of antibodies generated and hence the effectiveness of this methodology for the timely production of antibodies. We have carried out a comparative screening of two antibody libraries, a semi-synthetic scFv library and a human-derived Fab library against the protective antigen toxin component of Bacillus anthracis and the epsilon toxin of Clostridium botulinum. We have shown that while the synthetic library produced a diverse collection of specific scFv-phage, these contained a high frequency of unnatural amber stops and glycosylation sites which limited their conversion to IgG, and also a high number which lost specificity when expressed as IgG. In contrast, these limitations were overcome by the use of a natural human library. Antibodies from both libraries could be used to develop sandwich ELISA assays with similar sensitivity. However, the ease and speed with which full-length IgG could be generated from the human-derived Fab library makes screening this type of library the preferable method for rapid antibody generation for diagnostic assay development. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Validation of the kit ELISA (FAO, IAEA, PANAFTOSA) to determine antibodies against the virus of the foot-and-mouth disease

    International Nuclear Information System (INIS)

    Novel, Magaly; Ochoa, Carlos; Ramos, Pedro; Dominguez, Josefa de; Ruiz, Richard

    1997-01-01

    In Venezuela, endemic country for foot and mouth disease, the inmunoenzymatic test ELISA is not used in the routine diagnose for detection of antibodies against this illness. This fact determined that Panaftosa selected Venezuela as well as Argentina, Brazil, Colombia and Paraguay, to validate the kit developed by FAO - IAEA, in order to establish the point of cut value for each country. It is of high importance to precise the details of the technique in antigens (glycerinated or lyophilizated) so that, under equal conditions, national epidemic studies can be settle down, in such a way that its results can reorient the vaccination campaign and contribute to the Eradication of the Foot and Mouth Disease in Southamerican Countries. In this first stage 622 serums were processed, vaccinated animal (200), virgin (400), and coming from farms where the disease appeared (22). The analysis gave the screening in virgin animals among the 290 serums coming from Venezuela, with the result of 7 positive; this determined to continue insisting on requesting negative serums from Patagonia Argentina. The serum were received on September 14 of 1995 and mounting the screening in front of the Ag O and A, they were really negative to the ELISA test. From the screening of the 200 vaccinated animal serums, 48 were positive A (24%) and 33 positive to virus O (15.5); these results were taken with reservation, since the controls of antigens didn't give the value settled down in the protocol 1.0-1.5 [es

  13. Occurrence of nepoviruses in Rubus species in the Czech Republic.

    Science.gov (United States)

    Spak, J; Kubelková, D; Honetslegrová-Fránová, J

    1997-06-01

    The occurrence of arabis mosaic virus (AMV), raspberry ringspot virus (RRV), tomato black ring virus (TBRV), strawberry latent ringspot virus (SLRV) and cherry leaf roll virus (CLRV) in cultivated and wild plants of raspberry and blackberry has been studied in the Czech Republic in 1993-1996. Five hundred and seventy samples were collected at 51 localities and assayed by double antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA). The results represent the first evidence on the occurrence of AMV, RRV, TBRV and SLRV in cultivated Rubus species in the Czech Republic. Isolates AMV M20 and TBRV ML15 which were successfully transmitted by mechanical inoculation and characterized by reactions of differential host plants and by electron microscopy are the first isolates from Rubus from this territory. CLRV was not detected in either cultivated or wild Rubus species.

  14. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    OpenAIRE

    Alderete, J F

    1984-01-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...

  15. Stochastic simulation modeling to determine time to detect Bovine Viral Diarrhea antibodies in bulk tank milk

    DEFF Research Database (Denmark)

    Foddai, Alessandro; Enøe, Claes; Krogh, Kaspar

    2014-01-01

    A stochastic simulation model was developed to estimate the time from introduction ofBovine Viral Diarrhea Virus (BVDV) in a herd to detection of antibodies in bulk tank milk(BTM) samples using three ELISAs. We assumed that antibodies could be detected, after afixed threshold prevalence of seroco......A stochastic simulation model was developed to estimate the time from introduction ofBovine Viral Diarrhea Virus (BVDV) in a herd to detection of antibodies in bulk tank milk(BTM) samples using three ELISAs. We assumed that antibodies could be detected, after afixed threshold prevalence......, which was the most efficient ELISA, could detect antibodiesin the BTM of a large herd 280 days (95% prediction interval: 218; 568) after a transientlyinfected (TI) milking cow has been introduced into the herd. The estimated time to detectionafter introduction of one PI calf was 111 days (44; 605...

  16. High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Singh, Harpal; Morita, Takahiro; Suzuki, Yuma; Shimojima, Masayuki; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked immunosorbent assays (ELISA) are considered the gold standard in the demonstration of various immunological reactions with an application in the detection of infectious diseases such as during outbreaks or in patient care. This study aimed to produce an ELISA-based diagnostic with an increased sensitivity of detection compared to the standard 96-well method in the immunologic diagnosis of infectious diseases. A '3DStack' was developed using readily available, low cost fabrication technologies namely nanoimprinting and press stamping with an increased surface area of 4 to 6 times more compared to 96-well plates. This was achieved by stacking multiple nanoimprinted polymer sheets. The flow of analytes between the sheets was enhanced by rotating the 3DStack and confirmed by Finite-Element (FE) simulation. An Immunoglobulin G (IgG) ELISA for the detection of antibodies in human serum raised against Rubella virus was performed for validation. An improved sensitivity of up to 1.9 folds higher was observed using the 3DStack compared to the standard method. The increased surface area of the 3DStack developed using nanoimprinting and press stamping technologies, and the flow pattern between sheets generated by rotating the 3DStack were potential contributors to a more sensitive ELISA-based diagnostic device.

  17. Comparison of the serological tests ICT and ELISA for the diagnosis of alveolar echinococcosis in France.

    Science.gov (United States)

    Knapp, Jenny; Sako, Yasuhito; Grenouillet, Frédéric; Bresson-Hadni, Solange; Richou, Carine; Gbaguidi-Haore, Houssein; Ito, Akira; Millon, Laurence

    2014-01-01

    Serological diagnosis of alveolar echinococcosis (AE) is a key element for efficient patient treatment management. A rapid immunochromatography test kit (ICT) using the recombinant Em18 antigen (rEm18) was recently developed. The aim of our study was to assess this test on a panel of sera from French patients with alveolar echinococcosis and control patients. In a blind test, a total of 112 serum samples were tested including samples of AE (n = 30), cystic echinococcosis [CE] (n = 15), and polycystic echinococcosis [PE] (n = 1). For the comparison, 66 sera from patients with hepatocarcinoma, fascioliasis, toxocariasis, Caroli's disease, or autoimmune chronic active hepatitis were used. The diagnostic test sets we used were the rEm18-ICT and two validated ELISAs with rEm18 and Em2-Em18 antigens, respectively. For the ICT, 27/30 sera from AE patients, 4/15 sera from CE patients and the PE patient serum were positive. One serum from the control panel (toxocariasis) was positive for the ICT. The rEm18-ICT sensitivity (90.0%) and specificity (92.7%) for detection of Em18-specific antibodies confirmed it as a relevant tool for AE diagnosis. The rEm18-ELISA had a sensitivity of 86.7% and specificity of 91.5%, and the Em2-Em18-ELISA had a sensitivity of 96.7% and specificity of 87.8%. However, when AE patient sera are recorded as weak in intensity with the ICT, we recommend a double reading and use of a reference sample if the ICT is used for patient follow-up. © J. Knapp et al., published by EDP Sciences, 2014.

  18. Development of Strongylus vulgaris-specific serum antibodies in naturally infected foals.

    Science.gov (United States)

    Nielsen, M K; Vidyashankar, A N; Gravatte, H S; Bellaw, J; Lyons, E T; Andersen, U V

    2014-03-01

    Strongylus vulgaris is regarded as the most pathogenic helminth parasite infecting horses. Migrating larvae cause pronounced endarteritis and thrombosis in the cranial mesenteric artery and adjacent branches, and thromboembolism can lead to ischemia and infarction of large intestinal segments. A recently developed serum ELISA allows detection of S. vulgaris-specific antibodies during the six-month-long prepatent period. A population of horses has been maintained at the University of Kentucky without anthelmintic intervention since 1979, and S. vulgaris has been documented to be highly prevalent. In 2012, 12 foals were born in this population, and were studied during a 12-month period (March-March). Weekly serum samples were collected to monitor S. vulgaris specific antibodies with the ELISA. Nine colts underwent necropsy at different time points between 90 and 300 days of age. At necropsy, Strongylus spp. and Parascaris equorum were identified to species and stage and enumerated. Initial statistical findings indicate a significant interaction between foal age and ELISA results (pvulgaris-directed maternal antibodies transferred in the colostrum, but then remained ELISA negative during their first three months of life. Foals born in February and March became ELISA positive at about 12 weeks of age, while those born in April and May went positive at about 15 and 21 weeks, respectively. Foal date of birth was significantly associated with ELISA results (pvulgaris burdens (pvulgaris, S. edentatus, and P. equorum burdens (pvulgaris larvae leaving the bloodstream and migrating back to the intestine. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Evaluation of radioimmunoassay of anti-thyroglobulin antibodies

    International Nuclear Information System (INIS)

    Lourme, J.; Dessaint, J.P.; Capron, A.

    1985-01-01

    A statistical analysis is performed on the results of 881 determinations of thyroglobulin antibodies in humans. Antibodies were assayed comparatively by radioimmunoassay using a sandwich method and by tanned red cell haemagglutination. A very good concordance was found between the two techniques, apart from the low titer zone. A significant correlation was observed between on the one side, the radioactivity index of the diluted serum, defined as the increment of radioactivity bound by undiluted patient serum over the positive threshold, divided by this threshold, and, on the other side, the antibody titer, i.e. the reciprocal of the highest serum dilution superior to the positive threshold by radioimmunoassay. The corresponding linear regression allows to define a arbitrary unit system which associates values of the radioactivity index with an average antibody titer [fr

  20. Production of high titre antibody response against Russell's viper venom in mice immunized with ethanolic extract of fruits of Piper longum L. (Piperaceae) and piperine.

    Science.gov (United States)

    Shenoy, P A; Nipate, S S; Sonpetkar, J M; Salvi, N C; Waghmare, A B; Chaudhari, P D

    2014-01-15

    Piper longum L. fruits have been traditionally used against snakebites in north-eastern and southern region of India. The aim of the study was to assess the production of antibody response against Russell's viper venom in mice after prophylactic immunization with ethanolic extract of fruits of Piper longum L. and piperine. The mice sera were tested for the presence of antibodies against Russell's viper venom by in vitro lethality neutralization assay and in vivo lethality neutralization assay. Polyvalent anti-snake venom serum (antivenom) manufactured by Haffkine Bio-Pharmaceutical Corporation Ltd. was used as standard. Further confirmation of presence of antibodies against the venom in sera of mice immunized with PLE and piperine was done using indirect enzyme-linked immunosorbent assay (ELISA) and double immunodiffusion test. Treatment with PLE-treated mice serum and piperine-treated mice serum was found to inhibit the lethal action of venom both in the in vitro lethality neutralization assay and in vivo lethality neutralization assay. ELISA testing indicated that there were significantly high (pPiper longum and piperine produced a high titre antibody response against Russell's viper venom in mice. The antibodies against PLE and piperine could be useful in antivenom therapy of Russell's viper bites. PLE and piperine may also have a potential interest in view of the development of antivenom formulations used as antidote against snake bites. Copyright © 2013 Elsevier GmbH. All rights reserved.

  1. Radioimmunoassay of bovine leukosis virus antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Franz, J; Hampl, J; Svoboda, I; Granatova, M; Hofirek, B; Skrobak, F

    1986-08-01

    A RIA method was developed for identifying the presence of serum antibodies to the bovine leukosis virus. The chosen procedure uses the ability of the virus antigen to bind to the solid phase of a polystyrene carrier. The method was compared with the ELISA method and with the pseudoneutralization and immunodiffusion tests. A high level of agreement was achieved between the RIA and the ELISA methods (95%). By its accuracy the RIA method proves superior to the immunodiffusion test.

  2. A comparison of ELISA methods for the determination of human serum antibodies to Haemophilus influenzae type b

    NARCIS (Netherlands)

    van Gageldonk PGM; Mariani M; Berbers GAM; LVO-BI; Centro Ricerche; CHIRON S.p.A.; Siena; Italy/Laboratorio di Immunochimica e Sierologia Sperimentale/Departimento Immunologia

    1998-01-01

    Een vergelijking tussen de non-competitieve ELISA van Phipps et al., de klassieke radio-antigeen bindings assay (RABA) en de nieuw ontwikkelde Chiron competitieve ELISA voor de bepaling van anti-Hib polysaccharide (HibPs) antistof concentraties in humane sera wordt beschreven in het rapport. Voor

  3. Solid phase radioimmunoassays using labelled antibodies: a conceptual framework for designing assays

    International Nuclear Information System (INIS)

    Kalmakoff, J.; Parkinson, A.J.; Crawford, A.M.; Williams, B.R.G.

    1977-01-01

    A simple theoretical model for the antigen-antibody reaction is presented and used to evaluate the optimum conditions for designing solid phase radioimmunoassays (RIA) using labelled antibodies. Both theoretical and experimental data are presented, using a wide variety of antigens and their corresponding antibodies. The types of RIA described include the direct, the indirect, the direct sandwich assays for detecting either antigen or antibody. The experimental results confirm in a semiquantitative manner that the greatest sensitivity of the RIA is achieved when the smallest amount of labelled antibody is used, that whenever possible the antigen/antibody ratio should be greater than unity(>1), and that the formation of the antigen-antibody complex is dependent on the mass action effect

  4. Identifying anti-Toxocara IgG antibodies in horses of Mexico

    Directory of Open Access Journals (Sweden)

    R. Heredia

    Full Text Available ABSTRACT Both the presence of owned dogs and stray dogs allows the spread of Toxocara, a parasite whose eggs can be found in soil, water and food. Animals, including horses, serve as definitive and paratenic hosts. In México, where consumption of horse meat is common, Toxocara is a zoonotic parasite. The aim of this study was to identify the presence of anti-Toxocara antibodies in work horses and horses intended for human consumption by ELISA. ELISA was chosen for analysis as paratenic hosts do not shed Toxocara eggs in their feces. Blood samples were collected from a total of 188 horses, 94 of which were work horses and 94 horses from the slaughter house. Samples were analyzed by ELISA, and the general equine seroprevalence was found to be 44.6% (n = 188. Adult horses for slaughter had a 61.7% greater presence of anti-Toxocara antibodies (p = 0.006. Toxocara IgG antibodies were found in horses, confirming that horses are paratenic hosts and possible sources of infection for other animals and people.

  5. Evaluation of a Commercial Sandwich Enzyme-Linked Immunosorbent Assay for the Quantification of Beta-Casomorphin 7 in Yogurt Using Solid-Phase Extraction Coupled to Liquid Chromatography-Tandem Mass Spectrometry as the "Gold Standard" Method.

    Science.gov (United States)

    Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann

    2018-03-01

    This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.

  6. Short communication: ELISA system for screening of bovine mastitis caused by Prototheca zopfii.

    Science.gov (United States)

    Kano, Rui; Sato, Ayano; Sobukawa, Hideto; Sato, Yuko; Ito, Takaaki; Suzuki, Kazuyuki; Hasegawa, Atsuhiko; Kamata, Hiroshi

    2016-08-01

    Prototheca zopfii is an achlorophyllic alga that causes bovine mastitis, resulting in a reduction in milk production and the secretion of thin, watery milk with white flakes. This study evaluated the use of an ELISA system for distinguishing cows with mastitis due to P. zopfii genotype 2 from healthy cows and cows with chronic candidal mastitis. We also investigated the transitional changes of specific antibody titers in healthy cows injected with inactivated P. zopfii genotype 2 cells. The ELISA system exhibited the highest sensitivity (94%) and specificity (100%) for chronic protothecal mastitis when the positive cutoff value was set at 43.4 ELISA units. Anti-protothecal IgG titers were positive in all cows after they were inoculated with inactivated P. zopfii genotype 2 cells. These results indicated that ELISA detection of anti-protothecal IgG in serum provided specificity and sensitivity sufficient for diagnosing protothecal mastitis. Thus, an ELISA system incorporating this specific antiserum is expected to be valuable for definitive field-based diagnosis of bovine mastitis due to P. zopfii genotype 2. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Comparative diagnostic efficacy of recombinant LLO and PI-PLC-based ELISAs for detection of listeriosis in animals.

    Science.gov (United States)

    Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B

    2017-06-01

    The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (pPLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Detection of IgE in the sera of rodents: comparison of the applicability of ELISA and RIA

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, G; Zahner, H [Institut fuer Parasitologie der Justus-Liebig-Universitaet Giessen, Germany, F.R.; Haque, A [Institut Pasteur, 59 - Lille (France). Centre d' Immunologie et de Biologie Parasitaire

    1984-04-13

    RIA and ELISA were compared for their ability to detect IgE in different rodent species. With a sheep anti-rat IgE antibody good correlation (P < 0.001) between the 2 assay methods for IgE was found in rats. RIA failed to detect the IgE of Mastomys natalensis while ELISA proved to be a suitable test. However, both tests failed to measure IgE in sera of Nile rats.

  9. Detection of anti-Giardia lamblia serum antibody among children of day care centers

    Directory of Open Access Journals (Sweden)

    Guimarães Semíramis

    2002-01-01

    Full Text Available OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF and enzyme-linked immunosorbent assay (ELISA for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3% showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3% and 100 (68% samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39% than IIF (70%. IIF also showed a higher concordance with microscopic examination than ELISA.

  10. Polyclonal antibody to ovomucoid determination in gamma irradiated laying eggs

    International Nuclear Information System (INIS)

    Harder, Marcia N.C.; Arthur, Valter; Silva, Lucia C.A.S.; Lopes, Tatiana G.G.; Duarte, Keila M.R.; Canniatti-Brazaca, Solange G.; Savino, Vicente J.M.; Coelho, Antonio A.D.

    2009-01-01

    To determine allergenic food proteins, one of the most used tests is the immunoassays such as ELISA (enzyme linked immunosorbent assay), where the antibody recognizes the antigen and this connection is showed by an enzymatic system, in other words, optical density. The aim of this study was to determine the polyclonal antibody efficiency, produced in laboratory, to identify the presence the ovomucoid antigen in treated eggs by gamma irradiation for its inactivation. To evaluate the treatments, polyclonal antibody was produced in female rabbits immunized with bioconjugated ovomucoid. Was used Freund Complete Adjuvant at first immunization and PBS Buffer at four subsequently immunizations every fifteen days, plus a booster 48 hours before the blood retreated. The blood serum was tittered by PTA-ELISA (Plate trapped antigen). All procedures were according to European Norms for ethical and animal welfare. It was used, in nature, commercial laying eggs. So the samples were submitted to the gamma radiation coming from a source of Co 60 , type Multipurpose, under a dose rate of 19.4 and 31.8 Gy/hour, in the doses: 0 (control); 10 KGy; 20 KGy and 30 KGy, in all rates. By the ELISA.s test we can find the egg allergen ovomucoid and the radiation treatment do not showed considerable changes. So we can concluded that the antibody produced is capable of identify the ovomucoid allergenic protein and the gamma irradiation in such rates does not shows changes in that protein, therefore showed some changes in the color and visual viscosity of the egg samples. (author)

  11. Polyclonal antibody to ovomucoid determination in gamma irradiated laying eggs

    Energy Technology Data Exchange (ETDEWEB)

    Harder, Marcia N.C.; Arthur, Valter; Silva, Lucia C.A.S.; Lopes, Tatiana G.G. [Centro de Energia Nuclear na Agricultura (CENA/USP, Piracicaba, SP. Dept. de Radiobiologia e Ambiente) (Brazil)], e-mail: mnharder@cena.usp.br, e-mail: arthur@cena.usp.br, e-mail: tgglopes@cena.usp.br; Duarte, Keila M.R. [Instituto de Zootecnia (IZ . Nova Odessa), Nova Odessa, SP (Brazil)], e-mail: keila@iz.sp.gov.br; Canniatti-Brazaca, Solange G.; Savino, Vicente J.M.; Coelho, Antonio A.D. [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil)], e-mail: sgcbraza@esalq.usp.br, e-mail: vjmsavin@esalq.usp.br, e-mail: aadcoelh@esalq.usp.br

    2009-07-01

    To determine allergenic food proteins, one of the most used tests is the immunoassays such as ELISA (enzyme linked immunosorbent assay), where the antibody recognizes the antigen and this connection is showed by an enzymatic system, in other words, optical density. The aim of this study was to determine the polyclonal antibody efficiency, produced in laboratory, to identify the presence the ovomucoid antigen in treated eggs by gamma irradiation for its inactivation. To evaluate the treatments, polyclonal antibody was produced in female rabbits immunized with bioconjugated ovomucoid. Was used Freund Complete Adjuvant at first immunization and PBS Buffer at four subsequently immunizations every fifteen days, plus a booster 48 hours before the blood retreated. The blood serum was tittered by PTA-ELISA (Plate trapped antigen). All procedures were according to European Norms for ethical and animal welfare. It was used, in nature, commercial laying eggs. So the samples were submitted to the gamma radiation coming from a source of Co{sup 60}, type Multipurpose, under a dose rate of 19.4 and 31.8 Gy/hour, in the doses: 0 (control); 10 KGy; 20 KGy and 30 KGy, in all rates. By the ELISA.s test we can find the egg allergen ovomucoid and the radiation treatment do not showed considerable changes. So we can concluded that the antibody produced is capable of identify the ovomucoid allergenic protein and the gamma irradiation in such rates does not shows changes in that protein, therefore showed some changes in the color and visual viscosity of the egg samples. (author)

  12. The neo-epitope specific PRO-C3 ELISA measures true formation of type III collagen associated with liver and muscle parameters

    DEFF Research Database (Denmark)

    Nielsen, Mette J; Nedergaard, Anders F; Sun, Shu

    2013-01-01

    AIM: The present study describes the assessment of true formation of type III collagen in different pathologies using a neo-epitope specific competitive Enzyme-linked immunosorbent assay (ELISA) towards the N-terminal propeptide of type III collagen (PRO-C3). METHODS: The monoclonal antibody...... was raised against the N-protease mediated cleavage site of the N-terminal propeptide of type III collagen and a competitive ELISA was developed using the selected antibody. The assay was evaluated in relation to neo-epitope specificity, technical performance, and as a marker for liver fibrosis and muscle...... mass using the rat carbon tetrachloride (CCl4) model and a study of immobilization induced muscle loss in humans, respectively. RESULTS: The ELISA was neo-epitope specific, technically stable and can be assessed in serum and plasma samples. In the CCl4 liver fibrosis model it was observed that serum...

  13. Prevalence Estimates of Antibodies Towards Foot-and-Mouth Disease Virus in Small Ruminants in Uganda

    DEFF Research Database (Denmark)

    Balinda, Sheila Nina; Tjørnehøj, Kirsten; Muwanika, Vincent B.

    2009-01-01

    summarizes results of serological investigations of sheep and goats for antibodies to FMDV from four districts in 2006 following an FMD outbreak in the region and from an attempted comprehensive random sampling in two districts in 2007. Antibodies were quantified and serotyped using competitive ELISA...... for antibodies towards non-structural proteins (NSP) and structural proteins towards serotype O, and blocking ELISA for antibodies towards the seven serotypes of FMD virus (FMDV). In 2006, sheep and goats in Bushenyi and Isingiro districts were free from antibodies towards FMDV, while herds in Kasese and Mbarara...... districts excluding Kahendero village were all positive for antibodies towards NSP and SP-O. In 2007, mean prevalence estimates of antibodies towards FMDV NSP was 14% in goats and 22% in sheep in Kasese district, while Bushenyi was still free. The difference between these two districts probably reflects...

  14. Data on the characterization of follicle-stimulating hormone monoclonal antibodies and localization in Japanese eel pituitary

    Directory of Open Access Journals (Sweden)

    Dae-Jung Kim

    2016-09-01

    Full Text Available Monoclonal antibodies were generated against recombinant follicle-stimulating hormone (rec-FSH from Japanese eel Anguilla japonica; rec-FSH was produced in Escherichia coli and purified using Ni-NTA Sepharose column chromatography.In support of our recent publication, ''Production and characterization of monoclonal antibodies against recombinant tethered follicle-stimulating hormone from Japanese eel Anguilla japonica'' [1], it was important to characterize the specificity of eel follicle-stimulating hormone antibodies. Here, the production and ELISA system of these monoclonal antibodies are presented. The affinity-purified monoclonal antibodies specifically detected eel rec-FSH in ELISA and on western blots of rec-FSH produced from CHO cells. Immunohistochemical analysis revealed that FSH staining was specifically localized in the eel pituitary. Keywords: Japanese eel, FSH, Monoclonal Antibody

  15. Detection of IgG antibodies against Bordetella pertussis with 125I-protein A

    International Nuclear Information System (INIS)

    Wirsing von Koenig, C.H.; Finger, H.

    1981-01-01

    A method for the detection of IgG antibodies against Bordetella pertussis is described, based on the principle of 'sandwich' radioimmunoassay. 125 I protein A is used as radioactive tracer. The influence of amounts of antigen, antibody, radioactive tracer, incubation time and temperature were tested and the optimal conditions for the assay are described. The procedure offers a simple, quick, and sensitive method for detecting antibodies against B. pertussis. Application and limitation of the test are discussed. (orig.)

  16. Development of Immunoassay Based on Monoclonal Antibody Reacted with the Neonicotinoid Insecticides Clothianidin and Dinotefuran

    Directory of Open Access Journals (Sweden)

    Seiji Iwasa

    2012-11-01

    Full Text Available Enzyme-linked immunosorbent assay (ELISA based on a monoclonal antibody (MoAb was developed for the neonicotinoid insecticide clothianidin. A new clothianidin hapten (3-[5-(3-methyl-2-nitroguanidinomethyl-1,3-thiazol-2-ylthio] propionic acid was synthesized and conjugated to keyhole limpet hemocyanin, and was used for monoclonal antibody preparation. The resulting MoAb CTN-16A3-13 was characterized by a direct competitive ELISA (dc-ELISA. The 50% of inhibition concentration value with clothianidin was 4.4 ng/mL, and the working range was 1.5–15 ng/mL. The antibody showed high cross-reactivity (64% to dinotefuran among the structurally related neonicotinoid insecticides. The recovery examinations of clothianidin for cucumber, tomato and apple showed highly agreement with the spiked concentrations; the recovery rate was between 104% and 124% and the coefficient of variation value was between 1.8% and 15%. Although the recovery rate of the dc-ELISA was slightly higher than that of HPLC analysis, the difference was small enough to accept the dc-ELISA as a useful method for residue analysis of clothianidin in garden crops.

  17. Development of immunoassay based on monoclonal antibody reacted with the neonicotinoid insecticides clothianidin and dinotefuran.

    Science.gov (United States)

    Uchigashima, Mikiko; Watanabe, Eiki; Ito, Shigekazu; Iwasa, Seiji; Miyake, Shiro

    2012-11-15

    Enzyme-linked immunosorbent assay (ELISA) based on a monoclonal antibody (MoAb) was developed for the neonicotinoid insecticide clothianidin. A new clothianidin hapten (3-[5-(3-methyl-2-nitroguanidinomethyl)-1,3-thiazol-2-ylthio] propionic acid) was synthesized and conjugated to keyhole limpet hemocyanin, and was used for monoclonal antibody preparation. The resulting MoAb CTN-16A3-13 was characterized by a direct competitive ELISA (dc-ELISA). The 50% of inhibition concentration value with clothianidin was 4.4 ng/mL, and the working range was 1.5–15 ng/mL. The antibody showed high cross-reactivity (64%) to dinotefuran among the structurally related neonicotinoid insecticides. The recovery examinations of clothianidin for cucumber, tomato and apple showed highly agreement with the spiked concentrations; the recovery rate was between 104% and 124% and the coefficient of variation value was between 1.8% and 15%. Although the recovery rate of the dc-ELISA was slightly higher than that of HPLC analysis, the difference was small enough to accept the dc-ELISA as a useful method for residue analysis of clothianidin in garden crops.

  18. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  19. Radioimmunoassay of bovine leukosis virus antibodies

    International Nuclear Information System (INIS)

    Franz, J.; Hampl, J.; Svoboda, I.; Granatova, M.; Hofirek, B.; Skrobak, F.

    1986-01-01

    A RIA method was developed for identifying the presence of serum antibodies to the bovine leukosis virus. The chosen procedure uses the ability of the virus antigen to bind to the solid phase of a polystyrene carrier. The method was compared with the ELISA method and with the pseudoneutralization and immunodiffusion tests. A high level of agreement was achieved between the RIA and the ELISA methods (95%). By its accuracy the RIA method proves superior to the immunodiffusion test. (author)

  20. Comparison of four functionalization methods of gold nanoparticles for enhancing the enzyme-linked immunosorbent assay (ELISA

    Directory of Open Access Journals (Sweden)

    Paula Ciaurriz

    2017-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA technique is based on the specific recognition ability of the molecular structure of an antigen (epitope by an antibody and is likely the most important diagnostic technique used today in bioscience. With this methodology, it is possible to diagnose illness, allergies, alimentary fraud, and even to detect small molecules such as toxins, pesticides, heavy metals, etc. For this reason, any procedures that improve the detection limit, sensitivity or reduce the analysis time could have an important impact in several fields. In this respect, many methods have been developed for improving the technique, ranging from fluorescence substrates to methods for increasing the number of enzyme molecules involved in the detection such as the biotin–streptavidin method. In this context, nanotechnology has offered a significant number of proposed solutions, mainly based on the functionalization of nanoparticles from gold to carbon which could be used as antibody carriers as well as reporter enzymes like peroxidase. However, few works have focused on the study of best practices for nanoparticle functionalization for ELISA enhancement. In this work, we use 20 nm gold nanoparticles (AuNPs as a vehicle for secondary antibodies and peroxidase (HRP. The design of experiments technique (DOE and four different methods for biomolecule loading were compared using a rabbit IgG/goat anti-rabbit IgG ELISA model (adsorption, directional, covalent and a combination thereof. As a result, AuNP probes prepared by direct adsorption were the most effective method. AuNPs probes were then used to detect gliadin, one of the main components of wheat gluten, the protein composite that causes celiac disease. With this optimized approach, our data showed a sensitivity increase of at least five times and a lower detection limit with respect to a standard ELISA of at least three times. Additionally, the assay time was remarkably decreased.