WorldWideScience

Sample records for double wall houses

  1. Prefabricated EPS Elements used as Strip Foundation of a Single-family House with a Double Brick Wall

    OpenAIRE

    Rasmussen, Torben Valdbjørn

    2008-01-01

    A new prefabricated lightweight element was designed for a strip foundation that was demonstrated on site as the base of a single-family house with a double brick wall. The element was placed on a stable surface underneath the top soil layer, just 0.25 m underneath the finished ground surface. The prefabricated element was designed to fulfil the requirements of low energy consumption required by the new Danish Building Regulations. The base of the house was cast in one working operation and c...

  2. Prefabricated EPS Elements used as Strip Foundation of a Single-family House with a Double Brick Wall

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2008-01-01

    A new prefabricated lightweight element was designed for a strip foundation that was demonstrated on site as the base of a single-family house with a double brick wall. The element was placed on a stable surface underneath the top soil layer, just 0.25 m underneath the finished ground surface....... The prefabricated element was designed to fulfil the requirements of low energy consumption required by the new Danish Building Regulations. The base of the house was cast in one working operation and completed within two working days. The element, made of expanded polystyrene, was designed to be handled on site...

  3. Energy efficient residential house wall system

    International Nuclear Information System (INIS)

    Aldawi, Fayez; Date, Abhijit; Alam, Firoz; Khan, Iftekhar; Alghamdi, Mohammed

    2013-01-01

    The energy consumption and greenhouse gas emission by the residential housing sector are considered to be one of the largest in economically developed countries. The larger energy consumption and greenhouse gas emission not only put additional pressure on finite fossil fuel resources but also cause global warming and climate change. Additionally, the residential housing sector will be consuming more energy as the house demand and average house floor area are progressively increasing. With currently used residential house wall systems, it is hard to reduce energy consumption for ongoing house space heating and cooling. A smart house wall envelope with optimal thermal masses and insulation materials is vital for reducing our increasing energy consumption. The major aim of this study is to investigate thermal performance and energy saving potential of a new house wall system for variable climate conditions. The thermal performance modelling was carried out using commercially developed software AccuRate ® . The findings indicate that a notable energy savings can be accomplished if a smart house wall system is used. -- Highlights: • Smart house wall system. • Thermal performance modelling and star energy rating. • Energy savings and greenhouse gas reduction

  4. Reinforcement mechanism of multi-anchor wall with double wall facing

    Science.gov (United States)

    Suzuki, Kouta; Kobayashi, Makoto; Miura, Kinya; Konami, Takeharu; Hayashi, Taketo

    2017-10-01

    The reinforced soil wall has high seismic performance as generally known. However, the seismic behavior has not been clarified accurately yet, especially on multi-anchor wall with double wall facing. Indefinite behavior of reinforced soil wall during earthquake make us complicated in case with adopting to the abutment, because of arrangement of anchor plate as reinforcement often different according to the width of roads. In this study, a series of centrifuge model tests were carried out to investigate the reinforcement mechanism of multi anchor wall with double wall facing from the perspective of the vertical earth pressure. Several types of reinforce arrangement and rigid wall were applied in order to verify the arch function in the reinforced regions. The test results show unique behavior of vertical earth pressure, which was affected by arch action. All the vertical earth pressure placed behind facing panel, are larger than that of middle part between facing panel despite of friction between backfill and facing panel. Similar results were obtained in case using rigid wall. On the other hands, the vertical earth pressure, which were measured at the 3cm high from bottom of model container, shows larger than that of bottom. This results show the existence of arch action between double walls. In addition, it implies that the wall facing of such soil structure confined the backfill as pseudo wall, which is very reason that the multi anchor wall with double wall facing has high seismic performance.

  5. Revision of Sustainable Criteria of Concrete Walls for Earthquake-Resistant Housing

    Directory of Open Access Journals (Sweden)

    Alcocer S.M.

    2012-10-01

    Full Text Available The seismic performance of low-rise housing has been noticeably inadequate during the most recent earthquakes occurred in Latin American countries. Moreover, the literature review revealed that some traditional techniques do not contribute to building sustainable housing. In the last decade, construction of concrete walls housing has become a preferred choice because of the speed of construction and availability of materials in most of these countries. Aimed at improving seismic design methods for this type of construction, an extensive analytical and experimental program was carried out. The experimental program included quasi-static and shaking-table tests of 47 walls with different height-to-length ratios and walls with openings. Variables studied were type of concrete, web steel ratio and type of web reinforcement. The paper presents and discusses the main results of the research program and evaluates the technical and environmental feasibility for using concrete walls for sustainable and earthquake-resistant housing. Performance of concrete walls housing is assessed in terms of key environmental and earthquake-resistant requirements. It was found that concrete wall housing is not only safe under earthquakes and easily adaptable to climate, but also it stimulates environmental conservation and promotes reducing the costs of construction, operation and maintenance.

  6. John Hejduk ja tema Wall House 2 = John Hejduk and his Wall House 2 / Vilen Künnapu

    Index Scriptorium Estoniae

    Künnapu, Vilen, 1948-

    2010-01-01

    Ameerika arhitekt John Hejdukist ja tema mõjust 20. sajandi lõpukümnendite arhitektuurimõttele. Ka 1973. aastal projekteeritud eramust Wall House 2, mis valmis alles 2001. aastal Groningenis. Kommentaar Soome arhitektuuriprofessor Juhani Pallasmaalt

  7. Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double-stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. Moisture conditions in double-stud walls were monitored in Zone 5A (Massachusetts); three double-stud assemblies were compared.

  8. Monitoring of Double Stud Wall Moisture Conditions in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double stud walls have a higher risk of interior-sourced condensation moisture damage, when compared with high-R approaches using exterior insulating sheathing.; Moisture conditions in double stud walls were monitored in Zone 5A (Massachusetts); three double stud assemblies were compared.

  9. Transmission loss of double wall panels containing Helmholtz resonators

    Science.gov (United States)

    Prydz, R. A.; Kuntz, H. L.; Morrow, D. L.; Wirt, L. S.

    Data and an analysis are presented on the use of Helholtz resonators in double wall panels (i.e., aircraft sidewalls). Several wall materials and resonator configurations were tested, and the resonators were found to substantially increase the transmission loss of the double wall system at the tuning frequency.

  10. Electrochemical properties of double wall carbon nanotube electrodes

    OpenAIRE

    Pumera, Martin

    2007-01-01

    AbstractElectrochemical properties of double wall carbon nanotubes (DWNT) were assessed and compared to their single wall (SWNT) counterparts. The double and single wall carbon nanotube materials were characterized by Raman spectroscopy, scanning and transmission electron microscopy and electrochemistry. The electrochemical behavior of DWNT film electrodes was characterized by using cyclic voltammetry of ferricyanide and NADH. It is shown that while both DWNT and SWNT were significantly funct...

  11. Trombe walls with nanoporous aerogel insulation applied to UK housing refurbishments

    Directory of Open Access Journals (Sweden)

    Mark Dowson

    2014-10-01

    Full Text Available There is an opportunity to improve the efficiency of passive Trombe walls and active solar air collectors by replacing their conventional glass covers with lightweight polycarbonate panels filled with nanoporous aerogel insulation. This study investigates the thermal performance, energy savings, and financial payback period of passive Aerogel Trombe walls applied to the existing UK housing stock. Using parametric modeling, a series of design guidance tables have been generated, providing estimates of the energy savings and overheating risk associated with applying areas of Trombe wall to four different house types across the UK built to six notional construction standards. Calculated energy savings range from 183 kWh/m2/year for an 8 m2 system retrofitted to a solid walled detached house to 62 kWh/m2/year for a 32 m2 system retrofitted to a super insulated flat. Predicted energy savings from Trombe walls up to 24 m2 are found to exceed the energy savings from external insulation across all house types and constructions. Small areas of Trombe wall can provide a useful energy contribution without creating a significant overheating risk. If larger areas are to be installed, then detailed calculations would be recommended to assess and mitigate potential overheating issues.

  12. Double wall steam generator tubing

    International Nuclear Information System (INIS)

    Padden, T.R.; Uber, C.F.

    1983-01-01

    Double-walled steam generator tubing for the steam generators of a liquid metal cooled fast breeder reactor prevents sliding between the surfaces due to a mechanical interlock. Forces resulting from differential thermal expansion between the outer tube and the inner tube are insufficient in magnitude to cause shearing of base metal. The interlock is formed by jointly drawing the tubing, with the inside wall of the outer tube being already formed with grooves. The drawing causes the outer wall of the inner tube to form corrugations locking with the grooves. (author)

  13. Thermal effect on transverse vibrations of double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Zhang, Y Q; Liu, X; Liu, G R

    2007-01-01

    Based on the theory of thermal elasticity mechanics, a double-elastic beam model is developed for transverse vibrations of double-walled carbon nanotubes with large aspect ratios. The thermal effect is incorporated in the formulation. With this double-elastic beam model, explicit expressions are derived for natural frequencies and associated amplitude ratios of the inner to the outer tubes for the case of simply supported double-walled carbon nanotubes. The influence of temperature change on the properties of transverse vibrations is discussed. It is demonstrated that some properties of transverse vibrations of double-walled carbon nanotubes are dependent on the change of temperature

  14. Moisture Conditions in Passive House Wall Constructions

    OpenAIRE

    Gullbrekken, Lars; Geving, Stig; Time, Berit; Andresen, Inger

    2015-01-01

    Buildings for the future, i.e zero emission buildings and passive houses, will need well insulated building envelopes, which includes increased insulation thicknesses for roof, wall and floor constructions. Increased insulation thicknesses may cause an increase in moisture levels and thereby increased risk of mold growth. There is need for increased knowledge about moisture levels in wood constructions of well insulated houses, to ensure robust and moisture safe solutions. Monitoring of w...

  15. Current Status on the Development of a Double Wall Tube Steam Generator

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ho Yun; Choi, Byoung Hae; Kim, Jong Man; Kim, Byung Ho

    2007-12-15

    A fast reactor, which uses sodium as a coolant, has a lot of merits as a next generation nuclear reactor. However, the possibility of a sodium-water reaction occurrence hinders the commercialization of this reactor. As one way to improve the reliability of a steam generator, a double-wall tube steam generator is being developed in GEN-4 program. In this report, the current state of the technical developments for a double-wall tube steam generator are reviewed and a future plan for the development of a double-wall tube steam generator is established. The current focuses of this research are an improvement of the heat transfer capability for a double-wall tube and the development of a proper leak detection method for the failure of a double-wall tube during a reactor operation. The ideal goal is an on-line leak detection of a double wall tube to prevent the sodium-water reaction. However, such a method is not developed as yet. An alternative method is being used to improve the reliability of a steam generator by performing a non-destructive test of a double wall tube during the refueling period of a reactor. In this method a straight double wall tube is employed to perform this test easily, but has a difficulty regarding an absorption of a thermal expansion of the used materials. If an on-line leak detection method is developed, the demerits of a straight double-wall tube are avoided by using a helical type double-wall tube, and the probability of a sodium-water reaction can be reduced to a level less than the design-based accident.

  16. Role of intertube interactions in double- and triple-walled carbon nanotubes.

    Science.gov (United States)

    Hirschmann, Thomas Ch; Araujo, Paulo T; Muramatsu, Hiroyuki; Rodriguez-Nieva, Joaquin F; Seifert, Max; Nielsch, Kornelius; Kim, Yoong Ahm; Dresselhaus, Mildred S

    2014-02-25

    Resonant Raman spectroscopy studies are performed to access information about the intertube interactions and wall-to-wall distances in double- and triple-walled carbon nanotubes. Here, we explain how the surroundings of the nanotubes in a multiwalled system influence their radial breathing modes. Of particular interest, the innermost tubes in double- and triple-walled carbon nanotube systems are shown to be significantly shielded from environmental interactions, except for those coming from the intertube interaction with their own respective host tubes. From a comparison of the Raman results for bundled as well as individual fullerene-peapod-derived double- and triple-walled carbon nanotubes, we observe that metallic innermost tubes, when compared to their semiconducting counterparts, clearly show weaker intertube interactions. Additionally, we discuss a correlation between the wall-to-wall distances and the frequency upshifts of the radial breathing modes observed for the innermost tubes in individual double- and triple-walled carbon nanotubes. All results allow us to contemplate fundamental properties related to DWNTs and TWNTs, as for example diameter- and chirality-dependent intertube interactions. We also discuss differences in fullerene-peapod-derived and chemical vapor deposition grown double- and triple-walled systems with the focus on mechanical coupling and interference effects.

  17. Double-walled ZrO{sub 2} nanotube array. Preparation and enhanced photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Chaorui; Hu, Shengliang; Chang, Qing; Wang, Yanzhong [School of Materials Science and Engineering, North University of China, Taiyuan (China); Yang, Jinlong [School of Materials Science and Engineering, North University of China, Taiyuan (China); School of Materials Science and Engineering, Tsinghua University, Beijing (China)

    2017-11-15

    This work demonstrates the formation of self-ordered double-walled ZrO{sub 2} nanotube array via electrochemical anodization in glycerol-based electrolyte. Compared with its counterpart of single-walled ZrO{sub 2} nanotube array, the tube wall of double-walled ZrO{sub 2} nanotube split into outer and inner layers for the decomposition of glycerol during anodization process. Moreover, the double-walled structure showed its advantage of achieving improved utilization of light and higher specific surface area of nanotube array. Due to the unique double-walled structure, the double-walled ZrO{sub 2} nanotube array exhibited better photocatalytic activity than the single-walled ZrO{sub 2} nanotube array. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Elimination behavior of shelter dogs housed in double compartment kennels.

    Directory of Open Access Journals (Sweden)

    Denae Wagner

    Full Text Available For animals in confinement housing the housing structure has tremendous potential to impact well being. Dogs in animal shelters are often housed in one of two types of confinement housing - single kennels and rooms or double compartment kennels and rooms most often separated by a guillotine door. This study examines the effect of housing on the location of elimination behavior in dogs housed in double compartment kennels were the majority of the dogs were walked daily. One side of the kennel contained the food, water and bed and the other side was empty and available except during cleaning time. Location of urination and defecation was observed daily for 579 dogs housed in indoor double compartment kennels for a total of 4440 days of observation. There were 1856 days (41.9% when no elimination was noted in the kennel. Feces, urine or both were observed in the kennel on 2584 days (58.1%. When elimination occurred in the kennel the probability of fecal elimination on the opposite side of the bed/food/water was 72.5% (95% CI 69.05% to 75.69%. The probability of urination on the opposite side of the bed/food/water was 77.4% (95% CI 74.33% to 80.07%. This study demonstrates the strong preference of dogs to eliminate away from the area where they eat, drink and sleep. Double compartment housing not only allows this - it allows staff the ability to provide safe, efficient, humane daily care and confers the added benefits of reducing risks for disease transmission for the individual dog as well as the population.

  19. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-06-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution that provides insulation to the interior of the wall assembly with the use of a double stud wall. The guide describes two approaches to retrofitting the existing the walls: one involving replacement of the existing cladding, and the other that leaves the existing cladding in place. It discusses the design principles related to the use of various insulation types, and provides strategies and procedures for implementing the double stud wall retrofit. It also evaluates important moisture-related and indoor air quality measures that need to be implemented to achieve a durable, high performance wall.

  20. Improvement in transmission loss of aircraft double wall with resonators

    Science.gov (United States)

    Sun, Jincai; Shi, Liming; Ye, Xining

    1991-08-01

    A little volume low frequency resonator applicable to double-wall configuration of propeller-driven aircraft was designed on the basis of the principle of Helmholtz resonator. The normal incidence absorption coefficient of the various single resonator has been measured. The agreement between theoretical and experimental results is encouraging. An array of resonators whose resonant frequency at 85 Hz and 160 Hz, respectively, are installed between aircraft double-panel, and it has been shown that transmission loss of the double wall structure with resonators improve 4 dB and 6.5 dB in 1/3rd octave bandwidth at 80 Hz and 160 Hz center frequency, respectively, and 5 dB and 7 dB at resonant frequencies, compared with that of the double wall configuration without resonators.

  1. Study of noise reduction characteristics of double-wall panels

    Science.gov (United States)

    Navaneethan, R.; Quayle, B.; Stevenson, S.; Graham, M.

    1983-05-01

    The noise reduction characteristics of general aviation type, flat, double-wall structures were investigated. The experimental study was carried out on 20-by-20 inch panels with an exposed area of 18 by 18 inches. A frequency range from 20 to 5000 Hz was covered. The experimental results, in general, follow the expected trends. At low frequencies the double-wall structures are no better than the single-wall structures. However, for depths normally used in the general aviation industry, the double-wall panels are very attractive. The graphite-spoxy skin panels have higher noise reduction at very low frequencies ( 100 Hz) than the Kevlar skin panels. But the aluminum panels have higher noise reduction in the high frequency region, due to their greater mass. Use of fiberglass insulation is not effective in the low frequency region, and at times it is even negative. But the insulation is effective in the high-frequency region. The theoretical model for predicting the transmission loss of these multilayered panels is also discussed.

  2. Effect of doping on electronic properties of double-walled carbon and boron nitride hetero-nanotubes

    International Nuclear Information System (INIS)

    Majidi, R.; Ghafoori Tabrizi, K.; Jalili, S.

    2009-01-01

    The effect of boron nitride (BN) doping on electronic properties of armchair double-walled carbon and hetero-nanotubes is studied using ab initio molecular dynamics method. The armchair double-walled hetero-nanotubes are predicted to be semiconductor and their electronic structures depend strongly on the electronic properties of the single-walled carbon nanotube. It is found that electronic structures of BN-doped double-walled hetero-nanotubes are intermediate between those of double-walled boron nitride nanotubes and double-walled carbon and boron nitride hetero-nanotubes. Increasing the amount of doping leads to a stronger intertube interaction and also increases the energy gap.

  3. Effect of doping on electronic properties of double-walled carbon and boron nitride hetero-nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Majidi, R. [Department of Physics, Shahid Beheshti University, Evin, Tehran 19839-63113 (Iran, Islamic Republic of); Ghafoori Tabrizi, K., E-mail: K-TABRIZI@sbu.ac.i [Department of Physics, Shahid Beheshti University, Evin, Tehran 19839-63113 (Iran, Islamic Republic of); Jalili, S. [Department of Chemistry, K.N. Toosi University of Technology, Tehran 16315-1618 (Iran, Islamic Republic of)

    2009-11-01

    The effect of boron nitride (BN) doping on electronic properties of armchair double-walled carbon and hetero-nanotubes is studied using ab initio molecular dynamics method. The armchair double-walled hetero-nanotubes are predicted to be semiconductor and their electronic structures depend strongly on the electronic properties of the single-walled carbon nanotube. It is found that electronic structures of BN-doped double-walled hetero-nanotubes are intermediate between those of double-walled boron nitride nanotubes and double-walled carbon and boron nitride hetero-nanotubes. Increasing the amount of doping leads to a stronger intertube interaction and also increases the energy gap.

  4. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-06-22

    This Measure Guideline describes a deep energy enclosure retrofit solution that provides insulation to the interior of the wall assembly with the use of a double-stud wall. The guide describes two approaches to retrofitting the existing walls—one that involves replacing the existing cladding and the other that leaves the cladding in place. This guideline also covers the design principles related to the use of various insulation types and provides strategies and procedures for implementing the double-stud wall retrofit. It also includes an evaluation of important moisture-related and indoor air quality measures that need to be implemented to achieve a durable high-performance wall.

  5. Analysis of prestressed double-wall tubing for LMFBR steam generators

    International Nuclear Information System (INIS)

    Uber, C.F.; Langford, P.J.

    1981-01-01

    A radial interface pressure is provided between the inner and outer tubes of each double-wall tube in a steam generator design now being developed for commercial breeder reactor plants. This paper describes a finite element analysis of the manufacturing technique used to prestress the double-wall tube. The analytical predictions are compared with experimental measurements of the residual interface pressure. Resulting residual stress states are used as the starting point for operating condition analyses. 9 refs

  6. A Review of Double-Walled and Triple-Walled Carbon Nanotube Synthesis and Applications

    Directory of Open Access Journals (Sweden)

    Kazunori Fujisawa

    2016-04-01

    Full Text Available Double- and triple-walled carbon nanotubes (DWNTs and TWNTs consist of coaxially-nested two and three single-walled carbon nanotubes (SWNTs. They act as the geometrical bridge between SWNTs and multi-walled carbon nanotubes (MWNTs, providing an ideal model for studying the coupling interactions between different shells in MWNTs. Within this context, this article comprehensively reviews various synthetic routes of DWNTs’ and TWNTs’ production, such as arc discharge, catalytic chemical vapor deposition and thermal annealing of pea pods (i.e., SWNTs encapsulating fullerenes. Their structural features, as well as promising applications and future perspectives are also discussed.

  7. Synthesis of Titanium Dioxide Nanoparticles Using a Double-Slit Curved Wall-Jet Burner

    KAUST Repository

    Ismail, Mohamed; Mansour, Morkous S.; Memon, Nasir K.; Anjum, Dalaver H.; Chung, Suk-Ho

    2016-01-01

    A novel double-slit curved wall-jet (DS-CWJ) burner was proposed and utilized for flame synthesis. This burner was comprised of double curved wall-jet nozzles with coaxial slits; the inner slit was for the delivery of titanium tetraisopropoxide

  8. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Partnership for Home Innovation, Upper Marlboro, MD (United States); Wiehagen, Joseph [Partnership for Home Innovation, Upper Marlboro, MD (United States); Kochkin, Vladimir [Partnership for Home Innovation, Upper Marlboro, MD (United States)

    2016-01-01

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.

  9. Modelling the nonlinear behaviour of double walled carbon nanotube based resonator with curvature factors

    Science.gov (United States)

    Patel, Ajay M.; Joshi, Anand Y.

    2016-10-01

    This paper deals with the nonlinear vibration analysis of a double walled carbon nanotube based mass sensor with curvature factor or waviness, which is doubly clamped at a source and a drain. Nonlinear vibrational behaviour of a double-walled carbon nanotube excited harmonically near its primary resonance is considered. The double walled carbon nanotube is harmonically excited by the addition of an excitation force. The modelling involves stretching of the mid plane and damping as per phenomenon. The equation of motion involves four nonlinear terms for inner and outer tubes of DWCNT due to the curved geometry and the stretching of the central plane due to the boundary conditions. The vibrational behaviour of the double walled carbon nanotube with different surface deviations along its axis is analyzed in the context of the time response, Poincaré maps and Fast Fourier Transformation diagrams. The appearance of instability and chaos in the dynamic response is observed as the curvature factor on double walled carbon nanotube is changed. The phenomenon of Periodic doubling and intermittency are observed as the pathway to chaos. The regions of periodic, sub-harmonic and chaotic behaviour are clearly seen to be dependent on added mass and the curvature factors in the double walled carbon nanotube. Poincaré maps and frequency spectra are used to explicate and to demonstrate the miscellany of the system behaviour. With the increase in the curvature factor system excitations increases and results in an increase of the vibration amplitude with reduction in excitation frequency.

  10. The Leger house: an affordable super insulated home

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2000-03-01

    Building and energy efficient house in a cost-effective manner is not an easy task. The house described in this article is a 1200 sq.ft house, built on the principle of the Arkansas house, a sophisticated example of advanced wood frame construction, meets both these requirements, i.e. it is both energy efficient and good value for the money. It is built on a cast-in place concrete foundation with advanced framing construction techniques, staggered studs spaced on 24 inch centres, on separate plates forming an eight inch thick wall. The exterior sheathing is Dow Styrofoam, over which vinyl siding is installed. Thermal bridging, which is the weak point in conventional framing, received special attention. The outer walls are placed in such a way that they do not touch the floor joist and the plywood subfloor. Windows are wood framed, double glazed, a combination of casement and double hung, with storm windows, and sliding units. The clear span roof truss design gives the freedom of an open interior allowing a continuous unbroken ceiling vapour diffusion retarder. Drywall and oak flooring was installed without interference from partitions which were installed after the ceiling and the floor were in place. All lighting fixtures are on the partitions, so there is no need for penetration of the top plates in the partitions. Similarly, there is no wiring or plumbing in the exterior walls. Insulated steel doors, with magnetic weather stripping open to two airlocks. Domestic hot water and space heating is provided by a tank-less 43,800 Btu/hr Paloma natural gas heater. The water is kept at 160 degrees F and supplied to 46 feet of baseboard. A small conventional air-conditioning unit is installed but was only used for or a total of 12 hours since 1979, since during most of the hot summer days the rooms remain satisfactorily cool at about 80 degrees F, provided doors and windows are kept shut. A heat recovery ventilator has been installed subsequently, but is not considered

  11. Energy transmission through a double-wall curved stiffened panel using Green's theorem

    Science.gov (United States)

    Ghosh, Subha; Bhattacharya, Partha

    2015-04-01

    It is a common practice in aerospace and automobile industries to use double wall panels as fuselage skins or in window panels to improve acoustic insulation. However, the scientific community is yet to develop a reliable prediction method for a suitable vibro-acoustic model for sound transmission through a curved double-wall panel. In this quest, the present work tries to delve into the modeling of energy transmission through a double-wall curved panel. Subsequently the radiation of sound power into the free field from the curved panel in the low to mid frequency range is also studied. In the developed model to simulate a stiffened aircraft fuselage configuration, the outer wall is provided with longitudinal stiffeners. A modal expansion theory based on Green's theorem is implemented to model the energy transmission through an acoustically coupled double-wall curved panel. An elemental radiator approach is implemented to calculate the radiated energy from the curved surface in to the free field. The developed model is first validated with various numerical models available. It has been observed in the present study that the radius of curvature of the surface has a prominent effect on the behavior of radiated sound power into the free field. Effect of the thickness of the air gap between the two curved surfaces on the sound power radiation has also been noted.

  12. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Home Innovation Research Labs, Upper Marlboro, MD (United States); Wiehagen, Joseph [Home Innovation Research Labs, Upper Marlboro, MD (United States); Kochkin, Vladimir [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-29

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

  13. Controlled Release of Lysozyme from Double-Walled Poly(Lactide-Co-Glycolide (PLGA Microspheres

    Directory of Open Access Journals (Sweden)

    Rezaul H. Ansary

    2017-10-01

    Full Text Available Double-walled microspheres based on poly(lactide-co-glycolide (PLGA are potential delivery systems for reducing a very high initial burst release of encapsulated protein and peptide drugs. In this study, double-walled microspheres made of glucose core, hydroxyl-terminated poly(lactide-co-glycolide (Glu-PLGA, and carboxyl-terminated PLGA were fabricated using a modified water-in-oil-in-oil-in-water (w1/o/o/w2 emulsion solvent evaporation technique for the controlled release of a model protein, lysozyme. Microspheres size, morphology, encapsulation efficiency, lysozyme in vitro release profiles, bioactivity, and structural integrity, were evaluated. Scanning electron microscopy (SEM images revealed that double-walled microspheres comprising of Glu-PLGA and PLGA with a mass ratio of 1:1 have a spherical shape and smooth surfaces. A statistically significant increase in the encapsulation efficiency (82.52% ± 3.28% was achieved when 1% (w/v polyvinyl alcohol (PVA and 2.5% (w/v trehalose were incorporated in the internal and external aqueous phase, respectively, during emulsification. Double-walled microspheres prepared together with excipients (PVA and trehalose showed a better control release of lysozyme. The released lysozyme was fully bioactive, and its structural integrity was slightly affected during microspheres fabrication and in vitro release studies. Therefore, double-walled microspheres made of Glu-PLGA and PLGA together with excipients (PVA and trehalose provide a controlled and sustained release for lysozyme.

  14. Reliability of double-wall-tube steam generator for FBR considering water leak accident frequency

    International Nuclear Information System (INIS)

    Ueda, Nobuyuki; Kinoshita, Izumi; Nishi, Yoshihisa

    2000-01-01

    For early realization, a fast breeder reactor (FBR) is required to reduce construction cost. A reactor concept in which the intermediate heat transport system is eliminated by introducing a double-wall-tube steam generator is one convincing approach. The reliability of the double-wall-tube SG in a water leak accident (sodium-water reaction accident) due to tube failure is strongly related to the mitigating system design. The safety design of the double-wall-tube SG approach is investigated to limit the accident occurrence below 10 -7 (1/ry. A tube-to-tube weld is excluded from the reference design, because the welding process is too difficult and complicated to effectively prevent adhesion of the double-wall-tube. The reliability of the tube-to-tube plate was evaluated at 10 -10 (l/hr) for an inner tube and 10 -9 (l/hr) for an outer with reference to the failure experience of previous SGs. The failure must be detected within 30 to 60 minutes. (author)

  15. A mobility based vibroacoustic energy transmission simulation into an enclosure through a double-wall panel.

    Science.gov (United States)

    Sahu, Atanu; Bhattacharya, Partha; Niyogi, Arup Guha; Rose, Michael

    2017-06-01

    Double-wall panels are known for their superior sound insulation properties over single wall panels as a sound barrier. The sound transmission phenomenon through a double-wall structure is a complex process involving vibroacoustic interaction between structural panels, the air-cushion in between, and the secondary acoustic domain. It is in this context a versatile and a fully coupled technique based on the finite-element-boundary element model is developed that enables estimation of sound transfer through a double-wall panel into an adjacent enclosure while satisfying the displacement compatibility across the interface. The contribution of individual components in the transmitted energy is identified through numerical simulations.

  16. Electrostatically actuated oscillator of bundle and double-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jeong Won; Song, Ki Oh; Hwang, Ho Jung [Chung-Ang University, Seoul (Korea, Republic of); Lee, Jun Ha; Lee, Hoong Joo [Sangmyung University, Chonan (Korea, Republic of); Kwon, Oh Keun [Semyung University, Jecheon (Korea, Republic of); Yoon, Young Sik; Song, Young Jin [Konyang University, Nonsan (Korea, Republic of)

    2006-03-15

    Schematics of capacitively driven carbon nanotube (CNT) oscillators were presented and investigated by using classical molecular dynamics simulations. While the capacitive force acting on a CNT oscillator extruded it, the force exerted by the excess van der Waals energy sucked the CNT oscillator into the bundle or outer shell. The CNT oscillator could be oscillated by using both the Coulomb and the van der Waals interactions. The van der Waals force of the bundle-type CNT oscillator was less than the van der Waals force of the double-walled CNT oscillator. Molecular dynamics simulation results showed that double-walled CNT oscillators were better than bundle-type CNT oscillators in the aspects of both energy dissipation and stable operation.

  17. Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois B. [Steven Winter Associates, Inc., Norwalk, CT (United States). Consortium for Advanced Residential Buildings

    2016-07-13

    High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

  18. Energy characteristics of the double slot in the narrow wall of a rectangular waveguide

    OpenAIRE

    Martynenko, S. A.

    2005-01-01

    Based on approximation of the half-wave field distribution in the slots, an expression is derived for internal mutual conductance of closely-spaced slots, which form a double inclined slot in the narrow wall of a rectangular waveguide. The narrow wall has cut-outs reaching the broad wall. With the use of the method of induced magnetomotive forces, a mathematical model is devised for calculating the energy characteristics of the double slot. The impact of angle of inclination of the slots, dim...

  19. Life cycle cost of different Walling material used for affordable housing in tropics

    Directory of Open Access Journals (Sweden)

    Chameera Udawattha

    2017-12-01

    The results show that mud concrete block is the most suitable walling material. The brick has the highest account for the embedded energy. The hollow cement block is the worse building materials in tropics and its carbon footprint is comparatively higher. Even though the brick has higher embedded energy and construction cost, in a long run brick is less expensive than hollow cement block and Cabook walling material. Concluding, mud concrete block is comparatively most sustainable walling material for building affordable housing in tropics.

  20. 'Eco-house 99' - Full-scale demonstration of solar walls with building integrated heat storages

    Energy Technology Data Exchange (ETDEWEB)

    Hummelshoej, R.M.; Rahbek, J.E. [COWI Consulting Engineers and Planners AS (Denmark)

    2000-07-01

    A critical issue for solar systems in northern latitudes is the economic profitability. It is often said that the techniques for solar utilisation are expensive and unprofitable. This is, however, not always the case. A new project with 59 low energy terrace houses was carried out in Kolding, Denmark. The houses are designed as ecological buildings with emphasis on total economy based on low operation and maintenance costs, energy conservation and passive/hybrid solar utilisation. Besides direct solar gain through windows, each house has a solar wall of 6-8.5 m{sup 2} on the south facade. The solar walls are used both for heating of ventilation air and for space heating. The solar walls deliver heat to the dwellings during the heating season. To optimise the energy utilisation from the solar walls, the energy is stored internally in building integrated heat storages. Two different new types of prefabricated heat storages are built into the houses. One is an internal concrete wall with embedded ventilation pipes, and the other is a hollow concrete element with integrated stone bed. The heat storages are mainly designed to store solar energy from the day to the evening and the night. Because the solar walls and the heat storages have been a part of the design process from the start, the additional expenses are as low as 30-140 Euro/m{sup 2} solar wall compared with the alternative facade. This is far less than what it costs to add a solar wall on an existing building. Measurements over one year show that the yield of the solar walls is in the range of 115-125 kWh/m{sup 2}/year as expected. With the actual financing, the annual payment of the additional expenses for the solar systems is between 1-6 Euro/m{sup 2} solar wall, while the annual savings are about 5 Euro/year/m{sup 2} (with an energy price of 0.042 Euro/kWh). Dependent on which alternative facade construction the solar wall system is compared with, the profit of the system is in the range of 1 to +4 Euro

  1. Development of a helical-coil double wall tube steam generator for 4S reactor

    International Nuclear Information System (INIS)

    Kitajima, Yuko; Maruyama, Shigeki; Jimbo, Noboru; Hino, Takehisa; Sato, Katsuhiko

    2011-01-01

    The 4S, Super-Safe Small and Simple, is a small-sized sodium-cooled fast reactor. A fast reactor usually uses sodium as a coolant to transfer heat from core to turbine/generator system. The heat of the intermediate heat transport system and that of the water stream systems are exchanged by the steam generator (SG) tubes. If the tube failure occurs, a sodium/water reaction could be occurred. To prevent the reaction and enhance safety, a helical-coil-type double wall tube with wire mesh interlayer and continuous monitoring systems of tube failure are applied to the SG of the 4S. The development and general features of this type double wall tube were described in Ref. 1) and Ref. 2). Those paper summarized following results; The tubes studied in these references were straight type. To establish this SG, development of manufacturing method of helical-coil-type double wall tube and validation of the tube failure monitoring system are needed. In this study, three demonstration tests have been performed; welding test of the double wall tube to manufacture the tubes with 70-80m length, assembling test of the helical-coil tube, and confirmation test of the tube processing system using the fabricated helical-coil tubes. As a result, following technologies have been successfully established. (1) Development of the welding techniques for manufacturing of the helical-coil-type double wall tube with wire mesh interlayer. (2) The confirmation test for manufacturing the helical coil tube of the SG. (author)

  2. The electrostatic properties of Fiber-Reinforced-Plastics double wall underground storage gasoline tanks

    International Nuclear Information System (INIS)

    Li, Yipeng; Liu, Quanzhen; Meng, He; Sun, Lifu; Zhang, Yunpeng

    2013-01-01

    At present Fiber Reinforced Plastics (FRP) double wall underground storage gasoline tanks are wildly used. An FRP product with a resistance of more than 10 11 Ω is a static non-conductor, so it is difficult for the static electricity in the FRP product to decay into the earth. In this paper an experimental system was built to simulate an automobile gasoline filling station. Some electrostatic parameters of the gasoline, including volume charge density, were tested when gasoline was unloaded into a FRP double wall underground storage tank. Measurements were taken to make sure the volume charge density in the oil-outlet was similar to the volume charge density in the tank. In most cases the volume charge density of the gasoline was more than 22.7 μC m −3 , which is likely to cause electrostatic discharge in FRP double wall underground storage gasoline tanks. On the other hand, it would be hard to ignite the vapor by electrostatic discharge since the vapor pressure in the tanks is over the explosion limit. But when the tank is repaired or re-used, the operators must pay attention to the static electricity and some measurements should be taken to avoid electrostatic accident. Besides the relaxation time of charge in the FRP double wall gasoline storage tanks should be longer.

  3. Manufacturing studies of double wall components for the ITER EC H and CD upper launcher

    International Nuclear Information System (INIS)

    Spaeh, P.; Aiello, G.; Goldmann, A.; Kleefeldt, K.; Kroiss, A.; Meier, A.; Obermeier, C.; Scherer, T.; Schreck, S.; Serikov, A.; Strauss, D.; Vaccaro, A.

    2012-01-01

    Highlights: ► Double wall manufacturing technologies for ITER In-vessel components. ► Rigid and safe accommodation of ECRH heating and current drive systems. ► Thermo hydraulic analysis of coolant flow in double-wall structures. - Abstract: To counteract plasma instabilities, Electron Cyclotron Launchers will be installed in four of the ITER Upper Ports. The structural system of an EC Upper Launcher accommodates the MM-wave-components and has to meet strong demands on alignment, removal of nuclear heat loads, mechanical strength and nuclear shielding. The EC Upper Launcher has successfully undergone the Preliminary Design Review in 2009 and is now in the final design phase. Nuclear heat loads from 0.1 W/cm 3 up to 0.8 W/cm 3 will affect the front area of the launcher main frame. To guarantee save and homogenous removal of those heat loads, the front part of the launcher main frame is designed as a double wall steel-casing with cooling channels inside the shell structure. To finalize the design of this double wall component, the main emphasis is now to define the cooling channels geometry and to identify the optimum manufacturing route to assure adequate flow of coolant and sufficient mechanical strength in compliance with required dimension tolerances and quality of the welds. Several manufacturing options have been investigated and were evaluated by computational analysis and fabrication of pre-prototypes. To come to a final design, the most promising route will be chosen to manufacture a full-size mock-up of the double wall main frame. It will be tested at the KIT Launcher Handling Test facility to check the compliance with the design goals related to geometrical accuracy and thermo-hydraulic characteristics. This paper describes the design and the manufacturing routes of the prototypic double wall main frame.

  4. Manufacturing studies of double wall components for the ITER EC H and CD upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Spaeh, P., E-mail: peter.spaeh@kit.edu [Institute for Applied Materials, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Aiello, G. [Institute for Applied Materials, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Goldmann, A. [MAN Diesel and Turbo, D-94452 Deggendorf, P.O. Box 3640, D-76021 Karlsruhe (Germany); Kleefeldt, K. [Institute for Applied Materials, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Kroiss, A. [MAN Diesel and Turbo, D-94452 Deggendorf, P.O. Box 3640, D-76021 Karlsruhe (Germany); Meier, A. [Institute for Applied Materials, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Obermeier, C. [MAN Diesel and Turbo, D-94452 Deggendorf, P.O. Box 3640, D-76021 Karlsruhe (Germany); Scherer, T.; Schreck, S. [Institute for Applied Materials, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Serikov, A. [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany); Strauss, D.; Vaccaro, A. [Institute for Applied Materials, Karlsruhe Institute of Technology, P.O. Box 3640, D-76021 Karlsruhe (Germany)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Double wall manufacturing technologies for ITER In-vessel components. Black-Right-Pointing-Pointer Rigid and safe accommodation of ECRH heating and current drive systems. Black-Right-Pointing-Pointer Thermo hydraulic analysis of coolant flow in double-wall structures. - Abstract: To counteract plasma instabilities, Electron Cyclotron Launchers will be installed in four of the ITER Upper Ports. The structural system of an EC Upper Launcher accommodates the MM-wave-components and has to meet strong demands on alignment, removal of nuclear heat loads, mechanical strength and nuclear shielding. The EC Upper Launcher has successfully undergone the Preliminary Design Review in 2009 and is now in the final design phase. Nuclear heat loads from 0.1 W/cm{sup 3} up to 0.8 W/cm{sup 3} will affect the front area of the launcher main frame. To guarantee save and homogenous removal of those heat loads, the front part of the launcher main frame is designed as a double wall steel-casing with cooling channels inside the shell structure. To finalize the design of this double wall component, the main emphasis is now to define the cooling channels geometry and to identify the optimum manufacturing route to assure adequate flow of coolant and sufficient mechanical strength in compliance with required dimension tolerances and quality of the welds. Several manufacturing options have been investigated and were evaluated by computational analysis and fabrication of pre-prototypes. To come to a final design, the most promising route will be chosen to manufacture a full-size mock-up of the double wall main frame. It will be tested at the KIT Launcher Handling Test facility to check the compliance with the design goals related to geometrical accuracy and thermo-hydraulic characteristics. This paper describes the design and the manufacturing routes of the prototypic double wall main frame.

  5. Feasibility of applying cathodic protection to double-wall waste storage tanks

    International Nuclear Information System (INIS)

    Moore, E.L.

    1977-01-01

    A study was conducted to determine the feasibility of applying impressed current cathodic protection to double-wall storage tanks containing terminal waste solutions. Norton Corrosion Limited concluded that such a system could be designed for installation on the tanks. Under their direction, Battelle Northwest Laboratories conducted a laboratory study to develop necessary data for design of the system. A separate study conducted by Battelle Columbus Laboratories indicated that, while terminal waste solutions by themselves do not promote stress corrosion cracking, cathodic protection may promote this type of corrosion under certain conditions. As a result of these findings, the recommendation was made not to install cathodic protection on the double-wall tanks containing terminal waste solutions

  6. When double-wall carbon nanotubes can become metallic or semiconducting

    International Nuclear Information System (INIS)

    Moradian, Rostam; Azadi, Sam; Refii-tabar, Hashem

    2007-01-01

    The electronic properties of double-wall carbon nanotubes (DWCNTs) are investigated via density functional theory. The DWCNTs are separated into four categories wherein the inner-outer nanotubes are metal-metal, metal-semiconductor, semiconductor-metal and semiconductor-semiconductor single-wall nanotubes. The band structure of the DWCNTs, the local density of states of the inner and outer nanotubes, and the total density of states are calculated. We found that for the metal-metal DWCNTs, the inner and outer nanotubes remain metallic for different distances between the walls, while for the metal-semiconductor DWCNTs, decreasing the distance between the walls leads to a phase transition in which both nanotubes become metallic. In the case of semiconductor-metal DWCNTs, it is found that at some distance the inner wall becomes metallic, while the outer wall becomes a semiconductor, and if the distance is decreased, both walls become metallic. Finally, in the semiconductor-semiconductor DWCNTs, if the two walls are far from each other, then the whole DWCNT and both walls remain semiconducting. By decreasing the wall distance, first the inner, and then the outer, nanotube becomes metallic

  7. Flair Homes Project report no. 5. Airtightness performance of twenty detached houses over a two-year period

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G.; Beckman, J.

    1989-01-01

    Airtightness tests were performed on 20 new houses over a 2-year period in Winnipeg. The houses were constructed with a variety of air/vapor barrier systems and 3 different types of main walls. Polyethylene was used as the air/vapor barrier in 6 of the houses while the remaining 14 used the airtight drywall approach (ADA). The houses had similar floor plans and were constructed by the same builder. Both the polyethylene and ADA systems were found to be capable of meeting the airtightness requirements of the R-2000 standard with the tightest structures being double wall houses. No significant or permanent change in airtightness was observed for any of the houses over the monitoring period. Application of stucco as an exterior finish was found to improve airtightness of the ADA houses, but not of the double wall houses with polyethylene vapor barriers. Consistent sources of air leakage in the ADA houses were found to be the electrical outlets on exterior walls. Window leakage was also noted in many houses and the frequency of this leakage increased over the monitoring period. A significant leakage source was found to be an integrated mechanical system, which ducted in large volumes of outdoor air. It was also concluded there is a need to re-examine the design pressure requirements for residential air barrier systems. Specifically, this should investigate how transient wind-induced pressure loads are resisted by air barrier systems and whether some portion of the load is taken by other envelope components. An air leakage detection system was proposed consisting of a simple non-instrumented blower, which would be suitable for use by builders to aid in the construction of low leakage houses. 17 refs., 10 figs., 8 tabs.

  8. INTER-LAYER INTERACTION IN DOUBLE-WALLED CARBON NANOTUBES EVIDENCED BY SCANNING TUNNELING MICROSCOPY AND SPECTROSCOPY

    DEFF Research Database (Denmark)

    Giusca, Cristina E; Tison, Yann; Silva, S. Ravi P.

    2008-01-01

    and the overall electronic structure for double-walled carbon nanotubes, is demonstrated by our experiments, showing that the effect the inner tube has on the overall electronic structure of double-walled nanotubes cannot be neglected, and is key to the opto-electronic properties of the system. We postulate...... that previous analysis of the opto-electronic properties on multiple-walled carbon nanotubes based purely on the outer layer chirality of the tube needs significant modification based on new understanding brought forth with our analysis....

  9. DOUBLE-WALL COLLIMATOR DESIGN OF THE SNS PROJECT

    International Nuclear Information System (INIS)

    SIMOS, N.; LUDEWIG, H.; CATALAN-LASHERAS, N.; CRIVELLO, S.

    2001-01-01

    The collimator absorber array of the Spallation Neutron Source (SNS) project is responsible for stopping the 1.0 GeV protons that are in the halo of the beam. It is estimated that 0.1% of the 2 MW beam will be intercepted by the adopted collimating scheme implemented at various sections of the beam transport and accumulation. This paper summarizes the conceptual design of the collimator absorber as well as the supporting detailed analysis that were performed and guided the design process. Key requirement in the design process is the need for the collimator beam tube to minimize beam impedance while closely following its beta function. Due to lack of available experimental data, the long-term behavior of irradiated materials in an environment where they interface with coolant flow becomes an issue. Uncertainties in the long-term behavior prompted a special double-wall design that will enable not only beam halo interception but also the efficient transfer of deposited energy both under normal and off-normal conditions to the coolant flow. The thermo-mechanical response of the double wall beam tube and of a particle bed surrounding it are discussed in detail in the paper

  10. Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois B. [Steven Winter Associates, Inc., Norwalk, CT (United States). Consortium for Advanced Residential Buildings (CARB)

    2016-07-13

    High R-value wall assemblies (R-40 and above) are gaining popularity in the market due to programs such as the U.S. Department of Energy Zero Energy Ready Home program, Passive House, Net Zero Energy Home challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used double-wall systems to achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double-wall systems is that there are very few new exterior details. Exterior sheathings, structural bracings, house wraps or building paper, window and door flashings, and siding attachments are usually identical to good details in conventional framed-wall systems. However, although the details in double-wall systems are very similar to those in conventional stick framing, there is sometimes less room for error. Several studies have confirmed colder temperatures of exterior sheathing in high R-value wall assemblies that do not have exterior rigid foam insulation. These colder temperatures can lead to increased chances for condensation from air exfiltration, and they have the potential to result in moisture-related problems (Straube and Smegal 2009, Arena 2014, Ueno 2015). The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and reduce material brought to landfills due to failures and resulting decay. Although this document focuses on double-wall framing techniques, the majority of the information about how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture-related damage and are intended for builders, framing contractors, architects, and

  11. Frequency Characteristics of Double-Walled Carbon Nanotube Resonator with Different Length

    Directory of Open Access Journals (Sweden)

    Jun-Ha LEE

    2016-05-01

    Full Text Available In this paper, we have conducted classical molecular dynamics simulations for DWCNTs of various wall lengths to investigate their use as ultrahigh frequency nano-mechanical resonators. We sought to determine the variations in the frequency of these resonators according to changes in the DWCNT wall lengths. For a double-walled carbon nanotube resonator with a shorter inner nanotube, the shorter inner nanotube can be considered to be a flexible core, and thus, the length influences the fundamental frequency. In this paper, we analyze the variation in frequency of ultra-high frequency nano-mechnical resonators constructed from DWCNTs with different wall lengths.DOI: http://dx.doi.org/10.5755/j01.ms.22.2.12951

  12. Predicting the elastic properties of double-walled carbon nanotubes by molecular dynamics simulation

    International Nuclear Information System (INIS)

    Zhang Chenli; Shen Huishen

    2008-01-01

    Molecular dynamics simulation is performed on a double-walled carbon nanotube (DWCNT) to predict its elastic properties based on a double-walled shear deformable shell model. By direct buckling measurement, we present here a method for uniquely determining the effective wall thickness for the shell model. Accounting for two different kinds of DWCNTs by adding an inner or outer tube to a fiducial tube, the mechanical properties of DWCNTs are carefully investigated as compared with those of the fiducial tube. It is found that the predicted values of Young's and shear moduli depend strongly on the construction and helicity of DWCNTs, while the dependence on nanotube length is relatively small. The results also confirm that the temperature variation has a significant effect on the elastic properties of DWCNTs

  13. Butt-welding technology for double walled Polyethylene pipe

    International Nuclear Information System (INIS)

    Lee, Bo-Young; Kim, Jae-Seong; Lee, Sang-Yul; Kim, Yeong K.

    2012-01-01

    Highlights: ► We developed a butt welding apparatus for doubled walled Polyethylene pipe. ► We design the welding process by analyzing thermal behaviors of the material. ► We performed the welding and tested the welded structural performances. ► We also applied the same technology to PVC pipes. ► We verified the butt welding was successful and effective for the pipes with irregular sections. -- Abstract: In this study, mechanical analyses of a butt welding technology for joining Polyethylene pipe are presented. The pipe had unique structure with double wall, and its section topology was not flat. For an effective repair of leakage and replacements of the pipe, the butt welding technology was developed and tested. For the material characterizations, thermodynamic analyses such as thermal gravimetric analysis and differential scanning calorimetry were performed. Based on the test results, the process temperature and time were determined to ensure safe joining of the pipes using a hot plate apparatus. The welding process was carefully monitored by measuring the temperature. Then, the joined pipes were tested by various methods to evaluate the quality. The analyses results showed the detail process mechanism during the joining process, and the test results demonstrated the successful application of the technology to the sewage pipe repairs.

  14. Damping of double wall panels including a viscothermal air layer

    NARCIS (Netherlands)

    Basten, T.G.H.; Stainhaouer, G.; Bakamidis, S.; Charalabopoulou, F.

    2001-01-01

    This paper deals with the dynamic behaviour of double wall panels, with emphasis on damping and sound radiation. It will be shown that a narrow air layer separating the two plates of a panel significantly alters the mentioned quantities by its viscothermal properties. Numerical and experimental

  15. Double-walled silicon nanotubes: an ab initio investigation

    Science.gov (United States)

    Lima, Matheus P.

    2018-02-01

    The synthesis of silicon nanotubes realized in the last decade demonstrates multi-walled tubular structures consisting of Si atoms in {{sp}}2 and the {{sp}}3 hybridizations. However, most of the theoretical models were elaborated taking as the starting point {{sp}}2 structures analogous to carbon nanotubes. These structures are unfavorable due to the natural tendency of the Si atoms to undergo {{sp}}3. In this work, through ab initio simulations based on density functional theory, we investigated double-walled silicon nanotubes proposing layered tubes possessing most of the Si atoms in an {{sp}}3 hybridization, and with few {{sp}}2 atoms localized at the outer wall. The lowest-energy structures have metallic behavior. Furthermore, the possibility to tune the band structure with the application of a strain was demonstrated, inducing a metal-semiconductor transition. Thus, the behavior of silicon nanotubes differs significantly from carbon nanotubes, and the main source of the differences is the distortions in the lattice associated with the tendency of Si to make four chemical bonds.

  16. Effect of perforation on the sound transmission through a double-walled cylindrical shell

    Science.gov (United States)

    Zhang, Qunlin; Mao, Yijun; Qi, Datong

    2017-12-01

    An analytical model is developed to study the sound transmission loss through a general double-walled cylindrical shell system with one or two walls perforated, which is excited by a plane wave in the presence of external mean flow. The shell motion is governed by the classical Donnell's thin shell theory, and the mean particle velocity model is employed to describe boundary conditions at interfaces between the shells and fluid media. In contrast to the conventional solid double-walled shell system, numerical results show that perforating the inner shell in the transmission side improves sound insulation performance over a wide frequency band, and removes fluctuation of sound transmission loss with frequency at mid-frequencies in the absence of external flow. Both the incidence and azimuthal angles have nearly negligible effect on the sound transmission loss over the low and middle frequency range when perforating the inner shell. Width of the frequency band with continuous sound transmission loss can be tuned by the perforation ratio.

  17. Building America Case Study: Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation, Cold Climate Region

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

  18. Ab initio density functional theory investigation of structural and electronic properties of double-walled silicon carbide nanotubes

    Science.gov (United States)

    Moradian, Rostam; Behzad, Somayeh; Chegel, Raad

    2009-12-01

    By using ab initio density functional theory, the structural and electronic properties of (n,n)@(11,11) double-walled silicon carbide nanotubes (SiCNTs) are investigated. Our calculations reveal the existence of an energetically favorable double-walled nanotube whose interwall distance is about 4.3 Å. Interwall spacing and curvature difference are found to be essential for the electronic states around the Fermi level.

  19. Theoretical Study of α-V2O5 -Based Double-Wall Nanotubes.

    Science.gov (United States)

    Porsev, Vitaly V; Bandura, Andrei V; Evarestov, Robert A

    2015-10-05

    First-principles calculations of the atomic and electronic structure of double-wall nanotubes (DWNTs) of α-V2 O5 are performed. Relaxation of the DWNT structure leads to the formation of two types of local regions: 1) bulk-type regions and 2) puckering regions. Calculated total density of states (DOS) of DWNTs considerably differ from that of single-wall nanotubes and the single layer, as well as from the DOS of the bulk and double layer. Small shoulders that appear on edges of valence and conduction bands result in a considerable decrease in the band gaps of the DWNTs (up to 1 eV relative to the single-layer gaps). The main reason for this effect is the shift of the inner- and outer-wall DOS in opposite directions on the energetic scale. The electron density corresponding to shoulders at the conduction-band edges is localized on vanadium atoms of the bulk-type regions, whereas the electron density corresponding to shoulders at the valence-band edges belongs to oxygen atoms of both regions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. The Effects of Roof and Wall Insulation on the Energy Costs of Low Income Housing in Mexico

    Directory of Open Access Journals (Sweden)

    Jorge Lucero-Álvarez

    2016-06-01

    Full Text Available Environmental conditions, such as air temperature and solar radiation, have a complex relationship with the energy requirements for heating and cooling of residential buildings. In this work, a comparative analysis of the insulation methods most commonly applied to low income single-family houses in Mexico is presented, in order to find the most energy-efficient combinations of methods for the various climates in this country. A common kind of building, small houses built with hollow cinder block walls and concrete slab roofs, was analyzed considering three insulation scenarios: walls only, roof only and both. We used dynamic simulation to evaluate energy consumption under the climate conditions found in several Mexican cities. From the energy consumption data and the cost of electricity in Mexico, we calculated net annual energy costs, including both annual energy savings and the annualized cost of the initial investment in better insulation. Results of this analysis show that insulating both roof and walls is most effective in cities with cold winters; insulating just the roof is best for temperate climates; and insulating walls (combined with high-albedo roofs is most effective for cities with year-long warm weather.

  1. The control of radon levels in houses

    International Nuclear Information System (INIS)

    Al-Jarallah, M. B. I.

    2007-01-01

    The article speaks about radon entry ways to houses, the technologies of controlling the level of radon in indoors and four possible ways to solve the problem of high concentration of radon gas in housing and protection from being gathered to a certain extent that is harmful to health. These methods are: removal of the radon source, modifying the radon source, ventilation and air filtration. The article also addresses the impact of reducing the consumption of heating energy in homes and buildings using thermal insulators in floors, walls, ceilings and doors and making double glazed windows that confine the air. It has been proven that there is a steady relationship between energy conservation measures in housing and the increase of radon concentration by two to three times. In a lot of buildings, where conservation measures have been taken, materials to conserve heat are used, which themselves launch radon and this may lead to increased levels of the gas in the housing.

  2. Uranium City radiation reduction program: further studies on remedial measures and radon infiltration routes for houses with block walls

    International Nuclear Information System (INIS)

    Leung, M.K.

    1980-01-01

    This report describes the results of tests of partial sealing of concrete block walls to prevent radon infiltration into houses in Uranium City, and gives the results of studies of radon migration through concrete block walls. Results of some laboratory tests on the effectiveness of concrete blocks as a radon barrier are included

  3. Tuning of Sorted Double-Walled Carbon Nanotubes by Electrochemical Charging

    Czech Academy of Sciences Publication Activity Database

    Kalbáč, Martin; Green, A. A.; Hersam, M. C.; Kavan, Ladislav

    2010-01-01

    Roč. 4, č. 1 (2010), s. 459-469 ISSN 1936-0851 R&D Projects: GA AV ČR IAA400400911; GA AV ČR IAA400400804; GA AV ČR KAN200100801; GA ČR GC203/07/J067; GA MŠk LC510 Institutional research plan: CEZ:AV0Z40400503 Keywords : double-walled carbon nanotubes * electrochemical gating * spectroelectrochemistry Subject RIV: CG - Electrochemistry Impact factor: 9.855, year: 2010

  4. Stress analysis of a double-wall vacuum vessel for ITER

    International Nuclear Information System (INIS)

    Conner, D.L.; Williamson, D.E.; Nelson, B.E.

    1991-01-01

    The preliminary structural analyses performed in support of the design of the vacuum vessel for the International Thermonuclear Experimental Reactor (ITER) are described. A thin, double-wall, all-welded structure is the proposed design concept analyzed. The results of the static stress analysis indicate the adequacy of such a structure. The effects of the proposed high-aspect-ratio design configuration on loading and stresses are also discussed. 4 refs., 6 figs., 1 tab

  5. Probing Charge Transfer between Shells of Double-Walled Carbon Nanotubes Sorted by Outer-Wall Electronic Type

    Czech Academy of Sciences Publication Activity Database

    Kalbáč, Martin; Green, A. A.; Hersam, M. C.; Kavan, Ladislav

    2011-01-01

    Roč. 17, č. 35 (2011), s. 9806-9815 ISSN 0947-6539 R&D Projects: GA AV ČR IAA400400911; GA AV ČR IAA400400804; GA AV ČR KAN200100801; GA ČR GAP204/10/1677; GA MŠk LC510; GA MŠk ME09060 Institutional research plan: CEZ:AV0Z40400503 Keywords : density-gradient ultracentrifugation * double-walled carbon nanotubes * electrochemistry Subject RIV: CG - Electrochemistry Impact factor: 5.925, year: 2011

  6. Vibro-acoustic modelling of aircraft double-walls with structural links using Statistical Energy Analysis

    Science.gov (United States)

    Campolina, Bruno L.

    The prediction of aircraft interior noise involves the vibroacoustic modelling of the fuselage with noise control treatments. This structure is composed of a stiffened metallic or composite panel, lined with a thermal and acoustic insulation layer (glass wool), and structurally connected via vibration isolators to a commercial lining panel (trim). The goal of this work aims at tailoring the noise control treatments taking design constraints such as weight and space optimization into account. For this purpose, a representative aircraft double-wall is modelled using the Statistical Energy Analysis (SEA) method. Laboratory excitations such as diffuse acoustic field and point force are addressed and trends are derived for applications under in-flight conditions, considering turbulent boundary layer excitation. The effect of the porous layer compression is firstly addressed. In aeronautical applications, compression can result from the installation of equipment and cables. It is studied analytically and experimentally, using a single panel and a fibrous uniformly compressed over 100% of its surface. When compression increases, a degradation of the transmission loss up to 5 dB for a 50% compression of the porous thickness is observed mainly in the mid-frequency range (around 800 Hz). However, for realistic cases, the effect should be reduced since the compression rate is lower and compression occurs locally. Then the transmission through structural connections between panels is addressed using a four-pole approach that links the force-velocity pair at each side of the connection. The modelling integrates experimental dynamic stiffness of isolators, derived using an adapted test rig. The structural transmission is then experimentally validated and included in the double-wall SEA model as an equivalent coupling loss factor (CLF) between panels. The tested structures being flat, only axial transmission is addressed. Finally, the dominant sound transmission paths are

  7. Computational study of the shift of the G band of double-walled carbon nanotubes due to interlayer interactions

    Science.gov (United States)

    Popov, Valentin N.; Levshov, Dmitry I.; Sauvajol, Jean-Louis; Paillet, Matthieu

    2018-04-01

    The interactions between the layers of double-walled carbon nanotubes induce a measurable shift of the G bands relative to the isolated layers. While experimental data on this shift in freestanding double-walled carbon nanotubes has been reported in the past several years, a comprehensive theoretical description of the observed shift is still lacking. The prediction of this shift is important for supporting the assignment of the measured double-walled nanotubes to particular nanotube types. Here, we report a computational study of the G-band shift as a function of the semiconducting inner layer radius and interlayer separation. We find that with increasing interlayer separation, the G band shift decreases, passes through zero and becomes negative, and further increases in absolute value for the wide range of considered inner layer radii. The theoretical predictions are shown to agree with the available experimental data within the experimental uncertainty.

  8. The role of leak air in a double-wall chimney

    Science.gov (United States)

    Lichtenegger, Klaus; Hebenstreit, Babette; Pointner, Christian; Schmidl, Christoph; Höftberger, Ernst

    2015-06-01

    In modern buildings with tight shells, often room-independent air supply is required for proper operation of biomass stoves. One possibility to arrange this supply is to use a double-wall chimney with flue gas leaving through the pipe and fresh air entering through the annular gap. A one-dimensional quasi-static model based on balance equations has been developed and compared with experimental data. Inclusion of leak air is crucial for reproduction of the experimental results.

  9. Rationalization and utilization of double-wall vacuum vessel for tokamak fusion facility

    International Nuclear Information System (INIS)

    Nakahira, Masataka

    2005-09-01

    Vacuum Vessel (VV) of ITER is difficult to apply a non-destructive in-service inspection (ISI) and then new safety concept is needed. Present fabrication standards are not applicable to the VV, because the access is limited to the backside of closure weld of double wall. Fabrication tolerance of VV is ± 5mm even the structure is huge as high as 10m. This accuracy requires a rational method on the estimation of welding deformation. In this report, an inherent safety feature of the tokamak is proved closing up a special characteristic of termination of fusion reaction due to tiny water leak. A rational concept not to require ISI without sacrificing safety is shown based on this result. A partial penetration T-welded joint is proposed to establish a rational fabrication method of double wall. Strength and susceptibility to crevice corrosion is evaluated for this joint and feasibility is confirmed. A rational method of estimation of welding deformation for large and complex structure is proposed and the efficiency is shown by comparing analysis and experimental results of full-scale test. (author)

  10. Thermodynamical double-flux ventilation system in individual house; Systeme de ventilation double flux thermodynamique en maison individuelle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This guidebook written by the French scientific and technical committee of the space heating, ventilation and air-conditioning industry (Costic) with the collaboration of the French association of coldness production engineering (AFF) and Electricite de France (EdF), presents the technical rules and practical advices for the installation of thermodynamical double-flux ventilation systems in residential houses. Content: heat pumps (standardization and regulation, choice and dimensioning of the auxiliary electrical supply, installation, acoustic precautions), aeraulic networks (standardization and regulation, choice and dimensioning, installation), thermal insulation, thermoregulation, control and start-up, maintenance. (J.S.)

  11. Experimental Investigation on the Influence of a Double-Walled Confined Width on the Velocity Field of a Submerged Waterjet

    Directory of Open Access Journals (Sweden)

    Xiaolong Ding

    2017-12-01

    Full Text Available The current research on confined submerged waterjets mainly focuses on the flow field of the impinging jet and wall jet. The double-sided wall vertically confined waterjet, which is widely used in many fields such as mining, cleaning and surface strengthening, has rarely been studied so far. In order to explore the influence of a double-sided wall confined width on the velocity field of submerged waterjet, an experiment was conducted with the application of 2D particle image velocimetry (PIV technology. The distribution of mean velocity and turbulent velocity in both horizontal and vertical planes was used to characterize the flow field under various confined widths. The results show that the vertical confinement has an obvious effect on the decay rate of the mean centerline velocity. When the confined width changes from 15 to 5, the velocity is reduced by 20%. In addition, with the decrease of the confined width, the jet has a tendency to spread horizontally. The vertically confined region induces a space hysteresis effect which changes the location of the transition region moving downstream. There are local negative pressure zones separating the fluid and the wall. This study of a double-walled confined jet provides some valuable information with respect to its mechanism and industrial application.

  12. Optically and biologically active mussel protein-coated double-walled carbon nanotubes.

    Science.gov (United States)

    Jung, Yong Chae; Muramatsu, Hiroyuki; Fujisawa, Kazunori; Kim, Jin Hee; Hayashi, Takuya; Kim, Yoong Ahm; Endo, Morinobu; Terrones, Mauricio; Dresselhaus, Mildred S

    2011-12-02

    A method of dispersing strongly bundled double-walled carbon nanotubes (DWNTs) via a homogeneous coating of mussel protein in an aqueous solution is presented. Optical activity, mechanical strength, as well as electrical conductivity coming from the nanotubes and the versatile biological activity from the mussel protein make mussel-coated DWNTs promising as a multifunctional scaffold and for anti-fouling materials. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Effects of external and gap mean flows on sound transmission through a double-wall sandwich panel

    Science.gov (United States)

    Liu, Yu; Sebastian, Alexis

    2015-05-01

    This paper studies analytically the effects of an external mean flow and an internal gap mean flow on sound transmission through a double-wall sandwich panel lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials, and the transfer matrix method with three types of boundary conditions is applied to solve the system simultaneously. The random incidence transmission loss in a diffuse field is calculated numerically, and the limiting angle of incidence due to total internal reflection is discussed in detail. The numerical predictions suggest that the sound insulation performance of such a double-wall panel is enhanced considerably by both external and gap mean flows particularly in the high-frequency range. Similar effects on transmission loss are observed for the two mean flows. It is shown that the effect of the gap mean flow depends on flow velocity, flow direction, gap depth and fluid properties and also that the fluid properties within the gap appear to influence the transmission loss more effectively than the gap flow. Despite the implementation difficulty in practice, an internal gap flow provides more design space for tuning the sound insulation performance of a double-wall sandwich panel and has great potential for active/passive noise control.

  14. Double-walled control valves for the transport of liquids presenting a water pollution hazard; Doppelwandige Stellventile fuer den Transport wassergefaehrdender Fluessigkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Daume, A.; Weissberg, S. [Daume Regelarmaturen GmbH, Isernhagen (Germany)

    2004-09-01

    Under German law valves, vessels and connecting pipework containing and/or transporting hazardous substances must be fitted with watertight drip pans or moniterable double walls. This article describes double-walled control valves which are very well suited to meet plant operators' safety requirements and environmental protection requirements. In addition to environmental protection, the valves provide opportunities for cost savings. (orig.)

  15. Dynamic wall demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Nakatsui, L.; Mayhew, W.

    1990-12-01

    The dynamic wall concept is a ventilation strategy that can be applied to a single family dwelling. With suitable construction, outside air can be admitted through the exterior walls of the house to the interior space to function as ventilation air. The construction and performance monitoring of a demonstration house built to test the dynamic wall concept in Sherwood Park, Alberta, is described. The project had the objectives of demonstrating and assessing the construction methods; determining the cost-effectiveness of the concept in Alberta; analyzing the operation of the dynamic wall system; and determining how other components and systems in the house interact with the dynamic wall. The exterior wall construction consisted of vinyl siding, spun-bonded polyolefin-backed (SBPO) rigid fiberglass sheathing, 38 mm by 89 mm framing, fiberglass batt insulation and 12.7 mm drywall. The mechanical system was designed to operate in the dynamic (negative pressure) mode, however flexibility was provided to allow operation in the static (balanced pressure) mode to permit monitoring of the walls as if they were in a conventional house. The house was monitored by an extensive computerized monitoring system. Dynamic wall operation was dependent on pressure and temperature differentials between indoor and outdoor as well as wind speed and direction. The degree of heat gain was found to be ca 74% of the indoor-outdoor temperature differential. Temperature of incoming dynamic air was significantly affected by solar radiation and measurement of indoor air pollutants found no significant levels. 4 refs., 34 figs., 11 tabs.

  16. Electromagnetic properties of inner double walled carbon nanotubes investigated by nuclear magnetic resonance

    KAUST Repository

    Bouhrara, M.; Abou-Hamad, E.; Alabedi, G.; Al-Taie, I.; Kim, Y.; Wagberg, T.; Goze-Bac, C.

    2013-01-01

    The nuclear magnetic resonance (NMR) analytical technique was used to investigate the double walled carbon nanotubes (DWNTs) electromagnetic properties of inner walls. The local magnetic and electronic properties of inner nanotubes in DWNTs were analyzed using 25% 13C enriched C 60 by which the effect of dipolar coupling could be minimized. The diamagnetic shielding was determined due to the ring currents on outer nanotubes in DWNTs. The NMR chemical shift anisotropy (CSA) spectra and spin-lattice relaxation studies reveal the metallic properties of the inner nanotubes with a signature of the spin-gap opening below 70 K.

  17. Vertical single- and double-walled carbon nanotubes grown from modified porous anodic alumina templates

    International Nuclear Information System (INIS)

    Maschmann, Matthew R; Franklin, Aaron D; Amama, Placidus B; Zakharov, Dmitri N; Stach, Eric A; Sands, Timothy D; Fisher, Timothy S

    2006-01-01

    Vertical single-walled and double-walled carbon nanotube (SWNT and DWNT) arrays have been grown using a catalyst embedded within the pore walls of a porous anodic alumina (PAA) template. The initial film structure consisted of a SiO x adhesion layer, a Ti layer, a bottom Al layer, a Fe layer, and a top Al layer deposited on a Si wafer. The Al and Fe layers were subsequently anodized to create a vertically oriented pore structure through the film stack. CNTs were synthesized from the catalyst layer by plasma-enhanced chemical vapour deposition (PECVD). The resulting structure is expected to form the basis for development of vertically oriented CNT-based electronics and sensors

  18. Radiographic sensitivity evaluated by IQI DIN in double wall radiography and simple view

    International Nuclear Information System (INIS)

    Oliveira, C.S. de; Santos Filho, M. dos

    1983-01-01

    A comparison between the sensitivity of IQI-DIN put at the film side with the sensitivity of the IQI-DIN put at the source side, only for the double wall-simple view technique (DW-SW) is presented. An analysis about the requirements of radiographyic sensitivity in accordance to DIN rule is done. (E.G.) [pt

  19. Development of a 3D finite element acoustic model to predict the sound reduction index of stud based double-leaf walls

    Science.gov (United States)

    Arjunan, A.; Wang, C. J.; Yahiaoui, K.; Mynors, D. J.; Morgan, T.; Nguyen, V. B.; English, M.

    2014-11-01

    Building standards incorporating quantitative acoustical criteria to ensure adequate sound insulation are now being implemented. Engineers are making great efforts to design acoustically efficient double-wall structures. Accordingly, efficient simulation models to predict the acoustic insulation of double-leaf wall structures are needed. This paper presents the development of a numerical tool that can predict the frequency dependent sound reduction index R of stud based double-leaf walls at one-third-octave band frequency range. A fully vibro-acoustic 3D model consisting of two rooms partitioned using a double-leaf wall, considering the structure and acoustic fluid coupling incorporating the existing fluid and structural solvers are presented. The validity of the finite element (FE) model is assessed by comparison with experimental test results carried out in a certified laboratory. Accurate representation of the structural damping matrix to effectively predict the R values are studied. The possibilities of minimising the simulation time using a frequency dependent mesh model was also investigated. The FEA model presented in this work is capable of predicting the weighted sound reduction index Rw along with A-weighted pink noise C and A-weighted urban noise Ctr within an error of 1 dB. The model developed can also be used to analyse the acoustically induced frequency dependent geometrical behaviour of the double-leaf wall components to optimise them for best acoustic performance. The FE modelling procedure reported in this paper can be extended to other building components undergoing fluid-structure interaction (FSI) to evaluate their acoustic insulation.

  20. A Eutectic Melting Study of Double Wall Cladding Tubes of FeCrAl and Zircaloy-4

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Woojin; Son, Seongmin; Lee, You Ho; Lee, Jeong Ik; Ryu, Ho Jin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Jeong, Eun [Kyunghee University, Yongin (Korea, Republic of)

    2015-10-15

    The eutectic melting behavior of FeCrAl/Zircaloy-4 double wall cladding tubes was investigated by annealing at various temperatures ranging from 900 .deg. C to 1300 .deg. C. It was found that significant eutectic melting occurred after annealing at temperatures equal to or higher than 1150 .deg. C. It means that an additional diffusion barrier layer is necessary to limit the eutectic melting between FeCrAl and Zircaloy-4 alloy cladding tubes. Coating of FeCrAl layers on the Zr alloy cladding tube is being investigated for the development of accident tolerant fuel by exploiting of both the oxidation resistance of FeCrAl alloys and the neutronic advantages of Zr alloys. Coating of FeCrAl alloys on Zr alloy cladding tubes can be performed by various techniques including thermal spray, laser cladding, and co-extrusion. Son et al. also reported the fabrication of FeCrAl/Zr ally double wall cladding by the shrink fit method. For the double layered cladding tubes, the thermal expansion mismatch between the dissimilar materials, severe deformation or mechanical failure due to the evolution of thermal stresses can occur when there is a thermal cycling. In addition to the thermal stress problems, chemical compatibilities between the two different alloys should be investigated in order to check the stability and thermal margin of the double wall cladding at a high temperature. Generally, it is considered that Zr alloy cladding will maintain its mechanical integrity up to 1204 .deg. C (2200 .deg. F) to satisfy the acceptance criteria for emergency core cooling systems.

  1. Detailed energy saving performance analyses on thermal mass walls demonstrated in a zero energy house

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, L. [School of Architecture, Tianjin University, Tianjin 300072 (China); Hurt, R.; Correia, D.; Boehm, R. [Center for Energy Research, University of Nevada, Las Vegas, NV 89154 (United States)

    2009-03-15

    An insulated concrete wall system{sup 1}1 was used on exterior walls of a zero energy house. Its thermal functions were investigated using actual data in comparison to a conventional wood frame system. The internal wall temperature of massive systems changes more slowly than the conventional wall constructions, leading to a more stable indoor temperature. The Energy10 simulated equivalent R-value and DBMS of the mass walls under actual climate conditions are, respectively, 6.98 (m{sup 2} C)/W and 3.39. However, the simulated heating energy use was much lower for the massive walls while the cooling load was a little higher. Further investigation on the heat flux indicates that the heat actually is transferred inside all day and night, which results in a higher cooling energy consumption. A one-dimensional model further verified these analyses, and the calculated results are in good agreement with the actual data. We conclude that the thermal mass wall does have the ability to store heat during the daytime and release it back at night, but in desert climates with high 24-h ambient temperature and intense sunlight, more heat will be stored than can be transferred back outside at night. As a result, an increased cooling energy will be required. (author)

  2. Influence of PCMs on thermal behavior of building walls: experimental study using the walls of a reduced scale room

    Directory of Open Access Journals (Sweden)

    Gounni Ayoub

    2017-01-01

    Full Text Available Using Phase-Change Materials (PCM for lightweight building applications can increase equivalent thermal mass and provide energy savings. In the present experimental work, the heat transfer performance testing of some building walls, with or without PCM, is carried out using a reduced-scale cubic room (the test-cell. The cubic cell is heated by an incandescent bulb placed on its centre, and it is housed in an air-conditioned large-scale room that allows to control the ambient air temperature. The effect of the double PCM layer and of its location relatively to the outside surface of the wall is tested and discussed in terms of overall transmitted heat flux and in terms of reduction of the inside and outside surface temperatures. Findings shows that the additional inertia introduced by the PCM leads to a reduced overall heat flux transmission by the wall and to a lesser daily temperature amplitude on the surface of the wall that enhances the thermal comfort inside the building. In the next step of this work, the case of sandwich walls with air gap, and with wood and PCM layers will be considered.

  3. Influence of PCMs on thermal behavior of building walls: experimental study using the walls of a reduced scale room

    Science.gov (United States)

    Gounni, Ayoub; Tahar Mabrouk, Mohamed; Kheiri, Abdelhamid; El alami, Mustapha

    2017-11-01

    Using Phase-Change Materials (PCM) for lightweight building applications can increase equivalent thermal mass and provide energy savings. In the present experimental work, the heat transfer performance testing of some building walls, with or without PCM, is carried out using a reduced-scale cubic room (the test-cell). The cubic cell is heated by an incandescent bulb placed on its centre, and it is housed in an air-conditioned large-scale room that allows to control the ambient air temperature. The effect of the double PCM layer and of its location relatively to the outside surface of the wall is tested and discussed in terms of overall transmitted heat flux and in terms of reduction of the inside and outside surface temperatures. Findings shows that the additional inertia introduced by the PCM leads to a reduced overall heat flux transmission by the wall and to a lesser daily temperature amplitude on the surface of the wall that enhances the thermal comfort inside the building. In the next step of this work, the case of sandwich walls with air gap, and with wood and PCM layers will be considered.

  4. First-principles calculations on double-walled inorganic nanotubes with hexagonal chiralities

    International Nuclear Information System (INIS)

    Zhukovskii, Yuri F; Evarestov, Robert A; Bandura, Andrei V; Losev, Maxim V

    2011-01-01

    The two sets of commensurate double-walled boron nitride and titania hexagonally-structured nanotubes (DW BN and TiO 2 NTs) possessing either armchair- or zigzag-type chiralities have been considered, i.e., (n 1 ,n 1 )-(n 2 ,n 2 ) or (n 1 ,0)-(n 2 ,0), respectively. For symmetry analysis of these nanotubes, the line symmetry groups for one-periodic (1D) nanostructures with rotohelical symmetry have been applied. To analyze the structural and electronic properties of hexagonal DW NTs, a series of large-scale ab initio DFT-LCAO calculations have been performed using the hybrid Hartree-Fock/Kohn-Sham exchange-correlation functional PBE0 (as implemented in CRYSTAL-09 code). To establish the optimal inter-shell distances within DW NTs corresponding to the minima of calculated total energy, the chiral indices n 1 and n 2 of the constituent single-walled (SW) nanotubes have been successively varied.

  5. TiS2 and ZrS2 single- and double-wall nanotubes: first-principles study.

    Science.gov (United States)

    Bandura, Andrei V; Evarestov, Robert A

    2014-02-15

    Hybrid density functional theory has been applied for investigations of the electronic and atomic structure of bulk phases, nanolayers, and nanotubes based on titanium and zirconium disulfides. Calculations have been performed on the basis of the localized atomic functions by means of the CRYSTAL-2009 computer code. The full optimization of all atomic positions in the regarded systems has been made to study the atomic relaxation and to determine the most favorable structures. The different layered and isotropic bulk phases have been considered as the possible precursors of the nanotubes. Calculations on single-walled TiS2 and ZrS2 nanotubes confirmed that the nanotubes obtained by rolling up the hexagonal crystalline layers with octahedral 1T morphology are the most stable. The strain energy of TiS2 and ZrS2 nanotubes is small, does not depend on the tube chirality, and approximately obeys to D(-2) law (D is nanotube diameter) of the classical elasticity theory. It is greater than the strain energy of the similar TiO2 and ZrO2 nanotubes; however, the formation energy of the disulfide nanotubes is considerably less than the formation energy of the dioxide nanotubes. The distance and interaction energy between the single-wall components of the double-wall nanotubes is proved to be close to the distance and interaction energy between layers in the layered crystals. Analysis of the relaxed nanotube shape using radial coordinate of the metal atoms demonstrates a small but noticeable deviation from completely cylindrical cross-section of the external walls in the armchair-like double-wall nanotubes. Copyright © 2013 Wiley Periodicals, Inc.

  6. DOE ZERH Case Study: Mutual Housing California, Mutual Housing at Spring Lake, Woodland, CA

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning multifamily project of 62 affordable-housing apartment home in the hot-dry climate that exceeded CA Title 24-2008 by 35%, with 2x4 16” on center walls with R-21 fiberglass bass walls, uninsulated salb on grade foundation; vented attic with R-44 blown fiberglass; air to water heat pumps.

  7. Quantum interference effects on the intensity of the G modes in double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Tran, Huy Nam; Blancon, Jean-Christophe Robert; Arenal, Raul

    2017-01-01

    The effects of quantum interferences on the excitation dependence of the intensity of G modes have been investigated on single-walled carbon nanotubes [Duque et al., Phys. Rev. Lett.108, 117404 (2012)]. In this work, by combining optical absorption spectroscopy and Raman scattering on individual index identified double-walled carbon nanotubes, we examine the experimental excitation dependence of the intensity of longitudinal optical and transverse optical G modes of the constituent inner and outer single-walled carbon nanotubes. The observed striking dependencies are understood in terms of quantum interference effects. Considering such effects, the excitation dependence of the different components of the G modes permit to unambiguously assign each of them as originating from the longitudinal or transverse G modes of inner and outer tubes.

  8. First-principles calculations on double-walled inorganic nanotubes with hexagonal chiralities

    Energy Technology Data Exchange (ETDEWEB)

    Zhukovskii, Yuri F [Institute of Solid State Physics, University of Latvia, 8 Kengaraga Str., LV-1063, Riga (Latvia); Evarestov, Robert A; Bandura, Andrei V; Losev, Maxim V, E-mail: quantzh@latnet.lv [Department of Quantum Chemistry, St. Petersburg State University, 26 Universitetsky Ave., 198504, Petrodvorets (Russian Federation)

    2011-06-23

    The two sets of commensurate double-walled boron nitride and titania hexagonally-structured nanotubes (DW BN and TiO{sub 2} NTs) possessing either armchair- or zigzag-type chiralities have been considered, i.e., (n{sub 1},n{sub 1})-(n{sub 2},n{sub 2}) or (n{sub 1},0)-(n{sub 2},0), respectively. For symmetry analysis of these nanotubes, the line symmetry groups for one-periodic (1D) nanostructures with rotohelical symmetry have been applied. To analyze the structural and electronic properties of hexagonal DW NTs, a series of large-scale ab initio DFT-LCAO calculations have been performed using the hybrid Hartree-Fock/Kohn-Sham exchange-correlation functional PBE0 (as implemented in CRYSTAL-09 code). To establish the optimal inter-shell distances within DW NTs corresponding to the minima of calculated total energy, the chiral indices n{sub 1} and n{sub 2} of the constituent single-walled (SW) nanotubes have been successively varied.

  9. Energy-active walls for solar houses made by using energy accumulating panels with ecologically safe panels

    International Nuclear Information System (INIS)

    Alexandrov, Y.

    2006-01-01

    The paper presents the opportunities for separate assemblage and dismounting of the structural layers of energy-accumulating panels, meant for construction of energy-active walls, which could find an application in the process of building of so called 'solar houses'. A situation has been considered, for a panel, whose structure layers after the expiration of their operational term could be dismounted separately and could be recycled for secondary use

  10. Controlled-release and preserved bioactivity of proteins from (self-assembled core-shell double-walled microspheres

    Directory of Open Access Journals (Sweden)

    Yuan W

    2012-01-01

    Full Text Available Weien Yuan1,2, Zhenguo Liu11Department of Neurology, Xinhua Hospital, affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 2School of Pharmacy, Shanghai Jiao Tong University, Shanghai, People’s Republic of ChinaAbstract: In order to address preserved protein bioactivities and protein sustained-release problems, a method for preparing double-walled microspheres with a core (protein-loaded nanoparticles with a polymer-suspended granule system-formed core and a second shell (a polymer-formed shell for controlled drug release and preserved protein bioactivities has been developed using (solid-in-oil phase-in-hydrophilic oil-in-water (S/O/Oh/W phases. The method, based on our previous microsphere preparation method (solid-in-oil phase-in-hydrophilic oil-in-water (S/O/Oh/W, employs different concentric poly(D,L-lactide-co-glycolide, poly(D,L-lactide, and protein-loaded nanoparticles to produce a suspended liquid which then self-assembles to form shell-core microspheres in the hydrophilic oil phase, which are then solidified in the water phase. Variations in the preparation parameters allowed complete encapsulation by the shell phase, including the efficient formation of a poly(D,L-lactide shell encapsulating a protein-loaded nanoparticle-based poly(D,L-lactide-co-glycolide core. This method produces core-shell double-walled microspheres that show controlled protein release and preserved protein bioactivities for 60 days. Based upon these results, we concluded that the core-shell double-walled microspheres might be applied for tissue engineering and therapy for chronic diseases, etc.Keywords: protein delivery, protein stability, core-shell microspheres, dextran nanoparticles

  11. Evaluation on double-wall-tube residual stress distribution of sodium-heated steam generator by neutron diffraction and numerical analysis

    International Nuclear Information System (INIS)

    Kisohara, N.; Suzuki, H.; Akita, K.; Kasahara, N.

    2012-01-01

    A double-wall-tube is nominated for the steam generator heat transfer tube of future sodium fast reactors (SFRs) in Japan, to decrease the possibility of sodium/water reaction. The double-wall-tube consists of an inner tube and an outer tube, and they are mechanically contacted to keep the heat transfer of the interface between the inner and outer tubes by their residual stress. During long term SG operation, the contact stress at the interface gradually falls down due to stress relaxation. This phenomenon might increase the thermal resistance of the interface and degrade the tube heat transfer performance. The contact stress relaxation can be predicted by numerical analysis, and the analysis requires the data of the initial residual stress distributions in the tubes. However, unclear initial residual stress distributions prevent precious relaxation evaluation. In order to resolve this issue, a neutron diffraction method was employed to reveal the tri-axial (radius, hoop and longitudinal) initial residual stress distributions in the double-wall-tube. Strain gauges also were used to evaluate the contact stress. The measurement results were analyzed using a JAEA's structural computer code to determine the initial residual stress distributions. Based on the stress distributions, the structural computer code has predicted the transition of the relaxation and the decrease of the contact stress. The radial and longitudinal temperature distributions in the tubes were input to the structural analysis model. Since the radial thermal expansion difference between the inner (colder) and outer (hotter) tube reduces the contact stress and the tube inside steam pressure contributes to increasing it, the analytical model also took these effects into consideration. It has been conduced that the inner and outer tubes are contacted with sufficient stresses during the plant life time, and that effective heat transfer degradation dose not occur in the double-wall-tube SG. (authors)

  12. Superconductivity in bundles of double-wall carbon nanotubes.

    Science.gov (United States)

    Shi, Wu; Wang, Zhe; Zhang, Qiucen; Zheng, Yuan; Ieong, Chao; He, Mingquan; Lortz, Rolf; Cai, Yuan; Wang, Ning; Zhang, Ting; Zhang, Haijing; Tang, Zikang; Sheng, Ping; Muramatsu, Hiroyuki; Kim, Yoong Ahm; Endo, Morinobu; Araujo, Paulo T; Dresselhaus, Mildred S

    2012-01-01

    We present electrical and thermal specific heat measurements that show superconductivity in double-wall carbon nanotube (DWCNT) bundles. Clear evidence, comprising a resistance drop as a function of temperature, magnetoresistance and differential resistance signature of the supercurrent, suggest an intrinsic superconducting transition below 6.8 K for one particular sample. Additional electrical data not only confirm the existence of superconductivity, but also indicate the T(c) distribution that can arise from the diversity in the diameter and chirality of the DWCNTs. A broad superconducting anomaly is observed in the specific heat of a bulk DWCNT sample, which yields a T(c) distribution that correlates well with the range of the distribution obtained from the electrical data. As quasi one dimensionality of the DWCNTs dictates the existence of electronic density of state peaks, confirmation of superconductivity in this material system opens the exciting possibility of tuning the T(c) through the application of a gate voltage.

  13. Indication chamber of liquid metal fired steam generators with double wall for heat transfer

    International Nuclear Information System (INIS)

    Matal, O.; Martoch, J.

    1982-01-01

    The double wall of the steam generator consists of inner and outer tubes anchored in a tube plate. Between the tubes are indication spaces which end in recesses formed at least in one of the tube plates and coaxial with the outer tubes. The recesses interconnected with channels form the indication chamber to which is connected at least one sensor of the alarm signal equipment. (B.S.)

  14. A fast vibro-acoustic response analysis method for double wall structures including a viscothermal air layer

    NARCIS (Netherlands)

    Basten, T.G.H.; Grooteman, F.P.

    2000-01-01

    The damping behaviour of a thin air layer between two flexible panels can be used to reduce sound radiation of structural excited panels. The numerical model of the double wall panels takes into account full acousto-elastic interaction and viscothermal wave propagation in the air layer. This means

  15. Structural and electronic properties of boron-doped double-walled silicon carbide nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Behzad, Somayeh, E-mail: somayeh.behzad@gmail.co [Physics Department, Faculty of Science, Razi University, Kermanshah (Iran, Islamic Republic of); Moradian, Rostam [Physics Department, Faculty of Science, Razi University, Kermanshah (Iran, Islamic Republic of); Nano Science and Technology Research Center, Razi University, Kermanshah (Iran, Islamic Republic of); Computational Physical Science Research Laboratory, Department of Nano Science, Institute for Studies in Theoretical Physics and Mathematics (IPM), P.O. Box 19395-5531, Tehran (Iran, Islamic Republic of); Chegel, Raad [Physics Department, Faculty of Science, Razi University, Kermanshah (Iran, Islamic Republic of)

    2010-12-01

    The effects of boron doping on the structural and electronic properties of (6,0)-(14,0) double-walled silicon carbide nanotube (DWSiCNT) are investigated by using spin-polarized density functional theory. It is found that boron atom could be more easily doped in the inner tube. Our calculations indicate that a Si site is favorable for B under C-rich condition and a C site is favorable under Si-rich condition. Additionally, B-substitution at either single carbon or silicon atom site in DWSiCNT could induce spontaneous magnetization.

  16. Structural and electronic properties of boron-doped double-walled silicon carbide nanotubes

    International Nuclear Information System (INIS)

    Behzad, Somayeh; Moradian, Rostam; Chegel, Raad

    2010-01-01

    The effects of boron doping on the structural and electronic properties of (6,0)-(14,0) double-walled silicon carbide nanotube (DWSiCNT) are investigated by using spin-polarized density functional theory. It is found that boron atom could be more easily doped in the inner tube. Our calculations indicate that a Si site is favorable for B under C-rich condition and a C site is favorable under Si-rich condition. Additionally, B-substitution at either single carbon or silicon atom site in DWSiCNT could induce spontaneous magnetization.

  17. Structural and electronic properties of boron-doped double-walled silicon carbide nanotubes

    Science.gov (United States)

    Behzad, Somayeh; Moradian, Rostam; Chegel, Raad

    2010-12-01

    The effects of boron doping on the structural and electronic properties of (6,0)@(14,0) double-walled silicon carbide nanotube (DWSiCNT) are investigated by using spin-polarized density functional theory. It is found that boron atom could be more easily doped in the inner tube. Our calculations indicate that a Si site is favorable for B under C-rich condition and a C site is favorable under Si-rich condition. Additionally, B-substitution at either single carbon or silicon atom site in DWSiCNT could induce spontaneous magnetization.

  18. Effects of hydrogen adsorption on the properties of double wall BN and (BN){sub x}C{sub y} nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, A. [Departamento de Física, Universidade Federal da Paraíba, Caixa Postal 5008, 58059-900 João Pessoa, PB (Brazil); Azevedo, S., E-mail: sazevedo@fisica.ufpb.br [Departamento de Física, Universidade Federal da Paraíba, Caixa Postal 5008, 58059-900 João Pessoa, PB (Brazil); Kaschny, J.R. [Instituto Federal da Bahia – Campus Vitoria da Conquista, Avenida Amazonas 3150, 45030-220 Vitória da Conquista, BA (Brazil)

    2016-01-15

    In the present contribution, we apply first-principles calculations, based on the density functional theory, to study the effects of hydrogen adsorption on the structural and electronic properties of boron nitride and hybrid carbon–boron nitride double wall nanotubes. The results demonstrate that the hydrogen decoration induces significant structural deformation and an appreciable reduction in the gap energy. When the number of hydrogen atoms introduced on the outer wall is increased, desorption of hydrogen pairs are observed. The calculations indicate that each adsorbed hydrogen atom induces a structural deformation with an energetic cost of about 68 meV/atom. It is also found that the introduction of hydrogen atoms can be applied as an efficient tool for tuning the electronic properties of such structures. - Graphical abstract: Localized density of states of a hydrogenated double wall boron nitride nanotube. Some hydrogen pairs are desorbed, forming H{sub 2} molecules. - Highlights: • Hydrogenation induces structural deformation and reduction in the gap energy. • Each H atom induces a deformation with an energetic cost of about 68 meV/atom. • In some cases, desorption of H pairs from the outer wall is observed.

  19. Transformations, Inc.: Partnering to Build Net-Zero Energy Houses in Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Bergey, D. [Building Science Corporation, Somerville, MA (United States); Wytrykowska, H. [Building Science Corporation, Somerville, MA (United States)

    2013-09-01

    Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ('Devens'), The Homes at Easthampton Meadow ('Easthampton') andPhase II of the Coppersmith Way Development ('Townsend'). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers to specific research questions for homes with high R double stud walls and high efficiency ductlessair source heat pump systems ('mini-splits'); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.

  20. Transformations, Inc.. Partnering To Build Net-Zero Energy Houses in Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Bergey, D. [Building Science Corporation, Somerville, MA (United States); Wytrykowska, H. [Building Science Corporation, Somerville, MA (United States)

    2013-09-01

    Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ("Devens"), The Homes at Easthampton Meadow ("Easthampton") and Phase II of the Coppersmith Way Development ("Townsend"). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers to specific research questions for homes with high R double stud walls and high efficiency ductless air source heat pump systems ("mini-splits"); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.

  1. Cast-in-place concrete walls: thermal comfort evaluation of one-storey housing in São Paulo State

    Directory of Open Access Journals (Sweden)

    H. M. Sacht

    Full Text Available This paper presents a proposal of thermal performance evaluation of a one-storey housing typology (TI24A executed by CDHU - Companhia de Desenvolvimento Habitacional e Urbano do Estado de São Paulo, considering the use of cast-in-place monolithic panels of concrete, with different thicknesses panels (8, 10 and 12 cm and density between 1600 and 2400 kg/m³. In this study, the specific purpose was discussing the influence of the characteristic of concrete walls on the housing thermal performance without slab. Was defined of first parameters of study (definition of the one-storey housing typology, survey about housing users behavior and cities choose and executed computational simulation (winter and summer, for four São Paulo State cities (São Paulo, São Carlos, Santos e Presidente Prudente, with the software Arquitrop 3.0 in a one-storey housing. Was observed that in winter and summer the typologies analyzed, the panels thickness variation had more influence about results than different concrete densities. The minimum level of thermal performance (M in winter has been granted for some cities, with exception of Santos. In summer one of São Paulo city’s typology was attended the minimum level of thermal performance in agreement with standard “NBR 15575 Residential buildings up to five storied - Performance, Part 1: General requirements”.

  2. Multi-Stable Conductance States in Metallic Double-Walled Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Ci Lijie

    2009-01-01

    Full Text Available Abstract Electrical transport properties of individual metallic double-walled carbon nanotubes (DWCNTs were measured down to liquid helium temperature, and multi-stable conductance states were found in DWCNTs. At a certain temperature, DWCNTs can switch continuously between two or more electronic states, but below certain temperature, DWCNTs are stable only at one of them. The temperature for switching is always different from tube to tube, and even different from thermal cycle to cycle for the same tube. In addition to thermal activation, gate voltage scanning can also realize such switching among different electronic states. The multi-stable conductance states in metallic DWCNTs can be attributed to different Fermi level or occasional scattering centers induced by different configurations between their inner and outer tubes.

  3. HVI Ballistic Performance Characterization of Non-Parallel Walls

    Science.gov (United States)

    Bohl, William; Miller, Joshua; Christiansen, Eric

    2012-01-01

    The Double-Wall, "Whipple" Shield [1] has been the subject of many hypervelocity impact studies and has proven to be an effective shield system for Micro-Meteoroid and Orbital Debris (MMOD) impacts for spacecraft. The US modules of the International Space Station (ISS), with their "bumper shields" offset from their pressure holding rear walls provide good examples of effective on-orbit use of the double wall shield. The concentric cylinder shield configuration with its large radius of curvature relative to separation distance is easily and effectively represented for testing and analysis as a system of two parallel plates. The parallel plate double wall configuration has been heavily tested and characterized for shield performance for normal and oblique impacts for the ISS and other programs. The double wall shield and principally similar Stuffed Whipple Shield are very common shield types for MMOD protection. However, in some locations with many spacecraft designs, the rear wall cannot be modeled as being parallel or concentric with the outer bumper wall. As represented in Figure 1, there is an included angle between the two walls. And, with a cylindrical outer wall, the effective included angle constantly changes. This complicates assessment of critical spacecraft components located within outer spacecraft walls when using software tools such as NASA's BumperII. In addition, the validity of the risk assessment comes into question when using the standard double wall shield equations, especially since verification testing of every set of double wall included angles is impossible.

  4. Tuning Electronic Structures of BN and C Double-Wall Hetero-Nanotubes

    Directory of Open Access Journals (Sweden)

    Xueran Liu

    2015-01-01

    Full Text Available First principle calculations based on density functional theory with the generalized gradient approximation were carried out to investigate the energetic and electronic properties of carbon and boron nitride double-wall hetero-nanotubes (C/BN-DWHNTs with different chirality and size, including an armchair (n, n carbon nanotube (CNT enclosed in (m, m boron nitride nanotube (BNNT and a zigzag (n, 0 CNT enclosed in (m, 0 BNNT. The electronic structure of these DWHNTs under a transverse electric field was also investigated. The ability to tune the band gap with changing the intertube distance (di and imposing an external electric field (F of zigzag DWHNTs provides the possibility for future electronic and electrooptic nanodevice applications.

  5. Evolution Sustainable Green Inner-wall with Flexible Floor Plan

    Directory of Open Access Journals (Sweden)

    Tawil N.M.

    2014-01-01

    Full Text Available The trend of renovate residential houses especially the interior of the house has become a common phenomenon for homeowners nowadays in Malaysia. This scenario is quiet concern because sometimes no modifications to comply with the law and the guidelines set by the government housing. Modifications with not done properly can cause injury and harm to families and the people around. To reduce this problem, the concept of sustainable inner walls with flexible floor plan should be incorporated in every house in Malaysia. This is because the wall is the basic structure of a building and usually serves as the border, supporting structures and dividing the space with another space. Wall also causes an increase of the price of a house. This is due to the increase in raw material costs and labor costs, land subsidence have to bear by the developer. The increasing in house prices is causing among Malaysians, especially young executives cannot afford to buy their first home. To reduce the price of the home, reduction in construction interior wall in wet construction should be done and replaced with the sustainable inner wall. This sustainable inner wall also can save the space and the owner simplify can added or reduced the room according their need without spending too much money for renovation in the future.

  6. A study of radon activity inside some houses in Bangladesh

    International Nuclear Information System (INIS)

    Islam, G.S.; Islam, M.A.; Farid, S.M.; Rahman, A.

    1988-01-01

    The solid state nuclear track detector CR-39 has been used for long term measurements of the radon-222 emanation from building materials and the resultant activity inside houses in Bangladesh. Particular attention is paid to a special type of house with thick walls made entirely of mud. The radon-exhalation rate of the walls of these mud-built houses is found to be consistently higher than that of brick-built houses. (author)

  7. House Committee on Veterans' Affairs

    Science.gov (United States)

    ... the beaches of Normandy, from t... [...] Read Article House Doubles Down on Commitment to Veterans 08 Nov ... R-Tenn.) released the following statement after the House of Representatives passed nine veterans bills Tuesday and ...

  8. Synthesis of Titanium Dioxide Nanoparticles Using a Double-Slit Curved Wall-Jet Burner

    KAUST Repository

    Ismail, Mohamed

    2016-05-04

    A novel double-slit curved wall-jet (DS-CWJ) burner was proposed and utilized for flame synthesis. This burner was comprised of double curved wall-jet nozzles with coaxial slits; the inner slit was for the delivery of titanium tetraisopropoxide (TTIP) precursor while the outer one was to supply premixed fuel/air mixture of ethylene (C2H4) or propane (C3H8). This configuration enabled rapid mixing between the precursor and reactants along the curved surface and inside the recirculation zone of the burner. Particle growth of titanium dioxide (TiO2) nanoparticles and their phases was investigated with varying equivalence ratio and Reynolds number. Flow field and flame structure were measured using particle image velocimetry (PIV) and OH planar laser-induced fluorescence (PLIF) techniques, respectively. The nanoparticles were characterized using high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and nitrogen adsorption Brunauer–Emmett–Teller (BET) for surface area analysis. The flow field consisted of a wall-jet region leading to a recirculation zone, an interaction jet region, followed by a merged-jet region. The DS-CWJ burner revealed appreciable mixing characteristics between the precursor and combustion gases near the nozzle regions, with a slight increase in the axial velocity due to the precursor injection. The precursor supply had a negligible effect on the flame structure. The burner produced a reasonably uniform size (13–18 nm) nanoparticles with a high BET surface area (>100 m2/g). The phase of TiO2 nanoparticles was mainly dependent on the equivalence ratio and fuel type, which impact flame height, heat release rate, and high temperature residence time of the precursor vapor. For ethylene flames, the anatase content increased with the equivalence ratio, whereas it decreased in the case of propane flames. The synthesized TiO2 nanoparticles exhibited high crystallinity and the anatase phase was dominant at high equivalence

  9. Wood-framed houses for earthquake zones

    DEFF Research Database (Denmark)

    Hansen, Klavs Feilberg

    Wood-framed houses with a sheathing are suitable for use in earthquake zones. The Direction describes a method of determining the earthquake forces in a house and shows how these forces can be resisted by diaphragm action in the walls, floors, and roof, of the house. An appendix explains how...

  10. On the numerical investigation of sound transmission through double-walled structures with membrane-type acoustic metamaterials.

    Science.gov (United States)

    Marinova, Polina; Lippert, Stephan; von Estorff, Otto

    2017-10-01

    Acoustic metamaterials appear to be of great help in the design of reliable and effective noise reduction measures in the low frequency range. The current contribution is concerned with the modeling of a low-frequency noise shield, based on a double wall arrangement, which includes membrane-type acoustic metamaterials (MAMs), considered as the most promising approach when it comes especially to the tonal noise at frequencies below 300 Hz. MAMs consist of small-sized membranes loaded with a mass. Due to their robustness and relatively simple production, MAMs have been proven to decrease the sound transmission in frequency ranges, for which poro-elastic materials have a rather negligible effect. A simulation model of a double wall panel, whose acoustic cavity is furnished with layers of metamaterials, has been developed and the sound transmission loss (STL) through the structure was calculated, using the finite element method. In order to validate the modelling approach, the STL estimation from the finite element analysis was compared to experimental measurements. The achieved results indicate a noise-decreasing possibility in tunable narrow bands as well as a broadband noise reduction for frequencies less than 300 Hz without significantly adding to the panel mass.

  11. Double-wall carbon nanotubes doped with different Br2 doping levels: a resonance Raman study.

    Science.gov (United States)

    do Nascimento, Gustavo M; Hou, Taige; Kim, Yoong Ahm; Muramatsu, Hiroyuki; Hayashi, Takuya; Endo, Morinobu; Akuzawa, Noboru; Dresselhaus, Mildred S

    2008-12-01

    This report focuses on the effects of different Br2 doping levels on the radial breathing modes of "double-wall carbon nanotube (DWNT) buckypaper". The resonance Raman profile of the Br2 bands are shown for different DWNT configurations with different Br2 doping levels. Near the maximum intensity of the resonance Raman profile, mainly the Br2 molecules adsorbed on the DWNT surface contribute strongly to the observed omega(Br-Br) Raman signal.

  12. Motion control in double-walled carbon nanotube systems using a Stone-Thrower-Wales defect cluster

    International Nuclear Information System (INIS)

    Liu Ping; Zhang Yongwei

    2010-01-01

    The ability to control the motion of a single molecule will have an important impact in nano-mechanical systems. Multi-walled carbon nanotube systems, which have extremely low intertube friction and strong motion confinement, can form the basis for mechanically based motion control. We devise two molecular motion control units based on double-walled carbon nanotubes embedded with a Stone-Thrower-Wales defect cluster, and perform molecular dynamics simulations to determine the characteristics of these two control units. We show that one of the molecular control units is able to perform a logic operation on one logic input and produce three logic outputs, while the other is able to produce two logic outputs. Potential applications of the motion control units include molecular switches, shuttles and mechanically based logic devices.

  13. Extremely high thermal conductivity anisotropy of double-walled carbon nanotubes

    Directory of Open Access Journals (Sweden)

    Zhaoji Ma

    2017-06-01

    Full Text Available Based on molecular dynamics simulations, we reveal that double-walled carbon nanotubes can possess an extremely high anisotropy ratio of radial to axial thermal conductivities. The mechanism is basically the same as that for the high thermal conductivity anisotropy of graphene layers - the in-plane strong sp2 bonds lead to a very high intralayer thermal conductivity while the weak van der Waals interactions to a very low interlayer thermal conductivity. However, different from flat graphene layers, the tubular structures of carbon nanotubes result in a diameter dependent thermal conductivity. The smaller the diameter, the larger the axial thermal conductivity but the smaller the radial thermal conductivity. As a result, a DWCNT with a small diameter may have an anisotropy ratio of thermal conductivity significantly higher than that for graphene layers. The extremely high thermal conductivity anisotropy allows DWCNTs to be a promising candidate for thermal management materials.

  14. Evaluation of performance for solar house with Trombe wall. Part 6; Trombe kabeshiki solar house no hyoka kenkyu (toki tan`i ni okeru Trombe heki naihyomen kyuhonetsuryo no santei hoho no kento)

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, R.; Nakajima, Y. [Kogakuin University, Tokyo (Japan); Yoshida, N. [Nishimatsu Construction Co. Ltd., Tokyo (Japan); Watanabe, T. [Tokyo Electric Power Service Co. Ltd., Tokyo (Japan); Abe, H. [National Land Agency, Tokyo (Japan); Yamaga, K. [Mitsubishi Estate Co. Ltd., Tokyo (Japan)

    1997-11-25

    `Equivalent heat loss factor` used in the simplified load calculation method for the Trombe wall is a version modified to fit a solar house equipped with a Trombe wall. To compute the factor, it is necessary to input the quantities of Trombe wall inner surface absorbed/radiated heat for whose calculation the effect of the delay in solar heat storage by the Trombe wall has to be taken into consideration. The daily summation of the quantities of absorbed/radiated heat can be easily calculated using the day`s and the previous day`s insolation amounts. In this report, the hourly summation of the quantities of Trombe wall surface absorbed/radiated heat is performed by use of two variables which are the day`s and the previous day`s insolation amounts. In calculating the hourly summation of the quantities of absorbed/radiated heat, the daily summation of the quantities of absorbed/radiated heat is first calculated using the chart of predicted lines for the Trombe wall and, based on the data thus obtained, the quantities of absorbed/absorbed heat are divided and assigned to the respective hours and, as the result, approximations are obtained for the calculation of the hourly summation of the quantities of Trombe wall absorbed/radiated heat. A `time-dependent performance prediction curves for the Trombe wall` is proposed, which enables the visual comprehension of the effect of Trombe wall hourly units. 1 ref., 10 figs., 2 tabs.

  15. Subatmospheric double containment system

    International Nuclear Information System (INIS)

    Gans, D. Jr.; Noble, J.H.

    1978-01-01

    A reinforced concrete double wall nuclear containment structure with each wall including an essentially impervious membrane or liner and porous concrete filling the annulus between the two walls is described. The interior of the structure is maintained at subatmospheric pressure, and the annulus between the two walls is maintained at a subatmospheric pressure intermediate between that of the interior and the surrounding atmospheric pressure, during normal operation. In the event of an accident within the containment structure the interior pressure may exceed atmospheric pressure, but leakage from the interior to the annulus between the double walls will not result in the pressure of the annulus exceeding atmospheric pressure so that there is no net outleakage from the containment structure

  16. Coaxial stability of nano-bearings constructed by double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Huang Zaixing

    2008-01-01

    How to effectively control the coaxial stability of nano-bearings has an important influence on improving the quality of nano-bearings. Some relevant problems are studied in this paper. Firstly, we investigate basic non-coaxial modes in double-wall carbon nanotubes (DWCNTs). On the basis of analysis for these non-coaxial modes, a planar continuum model is established according to the principle of homogenization. By means of this model, a dynamic parameter λ* characterizing the coaxial stability of nano-bearings is determined. λ* is the explicit function of the angular velocity and interlayer spacing of DWCNTs. In terms of λ*, a criterion used to judge the coaxial stability of nano-bearings is given. Through discussing the influence of the angular velocity and interlayer spacing on the dynamic parameter λ*, some important conclusions are drawn

  17. The double-edged effects of annealing MgO underlayers on the efficient synthesis of single-wall carbon nanotube forests.

    Science.gov (United States)

    Tsuji, Takashi; Hata, Kenji; Futaba, Don N; Sakurai, Shunsuke

    2017-11-16

    Recently, the millimetre-scale, highly efficient synthesis of single-wall carbon nanotube (SWCNT) forests from Fe catalysts has been reported through the annealing of the magnesia (MgO) underlayer. Here, we report the double-edged effects of underlayer annealing on the efficiency and structure of the SWCNT forest synthesis through a temperature-dependent examination. Our results showed that the efficiency of the SWCNT forests sharply increased with increased underlayer annealing temperatures from 600 °C up to 900 °C due to a temperature-dependent structural modification, characterized by increased grain size and reduced defects, of the MgO underlayer. Beyond this temperature, the SWCNT fraction also decreased as a result of further structural modification of the MgO underlayer. This exemplifies the double-edged effects of annealing. Specifically, for underlayer annealing below 600 °C, the catalyst subsurface diffusion was found to limit the growth efficiency, and for excessively high underlayer annealing temperatures (>900 °C), catalyst coalescence/ripening led to the formation of double-wall carbon nanotubes. As a result, three distinct regions of synthesis were observed: (i) a "low yield" region below a threshold temperature (∼600 °C); (ii) an "increased yield" region from 600 to 900 °C, and (iii) a "saturation" region above 900 °C. The efficient SWCNT forest synthesis could only occur within a specific annealing temperature window as a result of this double-edged effects of underlayer annealing.

  18. Lateral resistance of plybamboo wall-panels

    OpenAIRE

    Gonzalez Beltran, G.E.; Herwijnen, van, F.; Janssen, J.J.A.; Moonen, S.P.G.; Gutierrez, J.A.

    2003-01-01

    This paper deals with the experimental and theoretical behavior of plybamboo (kind of plywood made out of bamboo) wall-panels subjected to lateral load. The wall-panels are part of a house design method proposed in the author's PhD thesis for prefabricated social housing in developing countries. Sixteen fullscaled wallpanels with or without window and door openings were tested and their theoretical capacities estimated. Design wind and seismic loads were determined according to the Internatio...

  19. Housing conditions and respiratory health in a Boston public housing community.

    Science.gov (United States)

    Brugge, D; Rice, P W; Terry, P; Howard, L; Best, J

    2001-01-01

    To determine frequency of and possible associations between environmental housing factors and self-reported respiratory symptoms in public housing. We used a community-participatory method in which trained residents conducted in-person interviews with a random sample of 53 households in one housing development in Boston, Massachusetts. Environmental factors suspected of affecting respiratory health that were reported by more than 30 percent of respondents included: Moisture (43 percent), mold (43 percent), cracks in walls, floors and ceilings (49 percent), sewage leaks (33 percent), unexplained odor (35 percent), use of air fresheners (91 percent), use of gas ovens for heating (38 percent), no vent for the oven (74 percent), stuffy air (66 percent), overheating at least part of the winter (73 percent), cockroaches (70 percent), rodents (40 percent), pets (39 percent), frequent renovations (40 percent), repeated requests for repairs (52 percent), dust from construction (45 percent), use of more than three hazardous household products (32 percent), vehicle traffic nearby (81 percent), and smoking in the household (57 percent). Forty percent of respondents reported having asthma. Respondents also reported that 56 percent of their children had asthma. Forty percent of respondents reported wheeze and 48 percent reported coughing or sneezing episodes in the preceding month. We found the following positive statistically significant associations, adjusted for age, sex, Black or Hispanic origin, and years lived in public housing: wheeze with moisture problems (OR = 4.8; CI = 1.2, 19.3), sewage leaks (OR = 6.3; CI = 1.3, 30.3), odor (OR = 7.5; CI = 1 .4, 39.0), cracks in walls,floors and ceilings (OR = 8.6; CI 1.9, 38.0), and frequency of renovations (OR = 9.8; CI = 1.8, 54.4); cough with moisture problems (OR = 5.3; CI = 1.3, 20.8), stuffy air (OR = 4.4; CI = 1.2, 16.7), cockroaches (OR = 5.4; CI = 1.2, 24.2), smoking (OR = 5.0; CI = 1.2, 20.5), odor (OR = 10.9; CI = 2

  20. S-layer and cytoplasmic membrane – exceptions from the typical archaeal cell wall with a focus on double membranes

    Directory of Open Access Journals (Sweden)

    Andreas eKlingl

    2014-11-01

    Full Text Available The common idea of typical cell wall architecture in archaea consists of a pseudo-crystalline proteinaceous surface layer (S-layer, situated upon the cytoplasmic membrane. This is true for the majority of described archaea, hitherto. Within the crenarchaea, the S-layer often represents the only cell wall component, but there are various exceptions from this wall architecture. Beside (glycosylated S-layers in (hyperthermophilic cren- and euryarchaea as well as halophilic archaea, one can find a great variety of other cell wall structures like proteoglycan-like S-layers (Halobacteria, glutaminylglycan (Natronococci, methanochondroitin (Methanosarcina or double layered cell walls with pseudomurein (Methanothermus and Methanopyrus. The presence of an outermost cellular membrane in the crenarchaeal species Ignicoccus hospitalis already gave indications for an outer membrane similar to Gram-negative bacteria. Although there is just limited data concerning their biochemistry and ultrastructure, recent studies on the euryarchaeal methanogen Methanomassiliicoccus luminyensis, cells of the ARMAN group, and the SM1 euryarchaeon delivered further examples for this exceptional cell envelope type consisting of two membranes.

  1. Housing: plastered versus un-plastered brooder walls in poultry ...

    African Journals Online (AJOL)

    An investigation was carried out to study the health impact of inadequate brooder house with poor make-up on chicks. Two brooder houses were constructed with a mixture of sand and cementitious materials consisting of lime and/or gypsum to form concrete blocks. Brooder 1 was plastered with cement (cemented) and ...

  2. The Effects of Housing Status, Stability and the Social Contexts of Housing on Drug and Sexual Risk Behaviors.

    Science.gov (United States)

    Dickson-Gomez, Julia; McAuliffe, Timothy; Quinn, Katherine

    2017-07-01

    Research on the relationship between housing instability and HIV risk has often focused on two different conceptions of stability. In one conceptualization, housing stability is defined according to physical location with homeless or unstably housed individuals defined as those who reside in places not meant for human habitation or in emergency shelters. The other conceptualization has defined housing stability as individuals' degree of transience, often operationalized as the number of moves or evictions a person has had within a specified amount of time. Less studied has been the social context of living situation, e.g. living with other drug users, conflict over living expenses, or having to have sex in order to stay. This paper uses data from 392 low-income residents in Hartford, CT to explore how people in different housing situations-including those who are housed and homeless-experience housing stability, feelings of security in their homes, and the social context of their housing. We then explore how these varied measures of housing context affect drug use frequency and sexual risk. Results show that participants who are homeless feel more overall housing instability in terms of number of moves and negative reasons for moving. Those who were doubled up with family or friends were more likely to experience conflict over household expenses and more likely to live with drug users. Among homeless and housed, hard drug use was associated with experiencing violence in the place where they lived, perceiving greater housing stability, having moved for a positive reason, doubling up, and longer periods of homelessness, while number of moves and longer prison sentence predicted sexual risk. Among the housed, living with other drug users was associated with more hard drug use, while contributing money toward household expenses was associated with less hard drug use. Two significant interactions were associated with sexual risk among the housed. Those with longer

  3. The structural and electronic properties of monovalent sidewall functionalized double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Jalili, Seifollah; Jamali, Maryam

    2012-01-01

    Highlights: ► (6,0)-(13,0) DWCNT, built from (6,0) and (13,0) SWCNTs, is a metallic nanotubes. ► NH 2 /(6,0)-(13,0) and COOH/(6,0)-(13,0) is semimetal and semiconductor, respectively. ► In NH 2 /(6,0)-(13,0) electrons transferred mainly from inner tube to NH 2 group. - Abstract: The structural and electronic properties of (6,0)-(13,0) double-walled carbon nanotubes (DWCNTs) and monovalent sidewall functionalized DWCNTs with –NH 2 and –COOH groups were studied using density functional theory. The results show that pure (6,0)-(13,0) DWCNTs are metallic. However, by functionalizing a DWCNT, local distortions are induced in the outer tube sidewall along the radial direction. The resulting structures, NH 2 /(6,0)-(13,0) and COOH/(6,0)-(13,0) DWCNTs, exhibit significant structural changes, and are semimetal with no energy gap and semiconducting with a small energy gap, respectively. In NH 2 /(6,0)-(13,0) DWCNTs, new electronic states are created and distributed on the outer wall and NH 2 group by electron transfer from the inner tube to the NH 2 group. In COOH/(6,0)-(13,0) DWCNTs, new states are created and distributed on the inner wall, but there is insignificant charge transfer between the inner tube and the COOH group. These results confirm that local atomic structural distortion on DWCNTs caused by sidewall functionalization can modify the electronic structures of DWCNTs.

  4. Energy conservation for houses and its calculation methods

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S H

    1981-04-01

    The concept of energy conservation of houses has been developed and began to be applied widely since the first oil crisis. Now we can say definitely that insulating a house is the most effective way of saving energy, and the renewable energy sources are useful only when the demand for space heating and hot water is minimized by insulating. If a house is well insulated, it will need a much smaller, simpler and cheaper heating system. So it will be less efficient to put a solar collector and wind generator on a poorly insulated house. Architects and engineers should have a certain level of practical knowledge of insulation for house to persuade customers using insulating materials and structure. Moreover, it is very essential to amend the existing building codes in order to facilitate this basic necessity. For instance, the Building Regulations of Denmark requires a U-value of 0.4 W/m/sup 2/ degC for heavy weight external wall. If the cavity wall has outer and inner leaf of just normal brick with internal finish of 20 mm cement mortar, which is a typical wall construction for houses in Korea, the thickness of insulation materials to the cavity can be calculated in order to fullfil the U-value of 0.4 W/m/sup 2/ degC in addition to the cavity of the external heavy wall: expanded polyurethane 58 mm, urea formaldehyde foam 67 mm, expanded polystyrene 78 mm, mineral wool 94 mm. The economic feasibility of solar heating system has been calculated. By applying 25% of the year inflation ratio for fuel cost, the result turns out economically comparable with solar heating systems.

  5. Design, fabrication and test of double-wall vacuum vessel for JT-60U

    International Nuclear Information System (INIS)

    Uchikawa, Takashi; Ioki, Kimihiro; Ninomiya, Hiromasa.

    1994-01-01

    A double-wall vacuum vessel was designed and fabricated for JT-60U (an upgraded machine of JT-60), which has a plasma current up to 6 MA and a large plasma volume (100 m 3 ). A new concept of Inconel 625 all-welded structure was adopted to the vessel, that comprises an inner plate, square tubes and an outer plate. The vacuum vessel with a multi-arc D-shaped cross section was fabricated by using hot-sizing press. The electromagnetic and structural analysis has been performed for plasma disruption loads. Dynamic responses of the vessel were measured during plasma disruptions, and the observed displacement had a good agreement with the result of FEM analysis. (author)

  6. Anharmonic properties of Raman modes in double wall carbon nano tubes

    Energy Technology Data Exchange (ETDEWEB)

    Marquina, J. [Universidad de los Andes, Facultad de Ciencias, Centro de Estudios Avanzados en Optica, 5101 Merida (Venezuela, Bolivarian Republic of); Power, Ch.; Gonzalez, J. [Universidad de los Andes, Facultad de Ciencias, Centro de Estudios en Semiconductores, 5101 Merida (Venezuela, Bolivarian Republic of); Broto, J. M. [Universite de Toulouse, Laboratoire National des Champs Magnetiques Intenses, CNRS UPR 3228, 31400 Toulouse (France); Flahaut, E., E-mail: castella@ula.v [Universite Paul Sabatier, Laboratoire de Chimie des Materiaux Inorganiques, UMR CNRS 5085, 31062 Toulouse (France)

    2011-07-01

    The temperature dependence of the radial breathing modes (RB Ms) and the zone-center tangential optical phonons (G-bands) of double-walled carbon nano tubes has been investigated between 300 and 700 K using Raman scattering. As expected, with increasing temperature, the frequencies of the Raman peaks, including the RB Ms and G-bands downshift simultaneously. We show here that the temperature dependence of the RB Ms can be fitted by a simple linear dependence and different RB Ms have different frequency shifts. We observe a noticeable nonlinearity in the temperature dependence of the G-band associated with the outer semiconducting tube G+ext (s). The deviation from the linear trend is due to the contribution of the third-order anharmonic term in the lattice potential energy with a pure temperature effect. An estimated value of 1.5 for the Grueneisen parameter of the G+ext (s) band was found. (Author)

  7. Study on image quality of radiograph in radiographic examination for circumferential welded joint. 1. Basic study on scattered radiation in double wall exposure technique

    International Nuclear Information System (INIS)

    Kato, Kiyoshi; Ooka, Norikazu.

    1997-01-01

    Wire type Image Quality Indicators (I. Q. I.) are usually used for the evaluation of the image quality of radiographs in radiographic examinations specified in the Japanese Industrial Standard (JIS). The relationship between the sensitivity of the Image Quality Indicator and the radiographic contrast in single wall exposure technique has already been well understood. However, the relationship in double wall exposure technique is still under discussion. As a result of the fundamental experiments using flat plates, it was found in this study that the image quality of radiograph depends on the ratio of scattered X-rays generated in the focus side test plate to transmitted X-rays, and that the ratio varies in inverse proportion to the distance between the flat plates. It was also shown that the simulation method based on the Compton Effect is effective in obtaining the ratio of scattered to transmitted X-rays in the double wall exposure technique for a pipe of more than 100 mm diameter. (author)

  8. House characteristics associated with gamma radiation and radon daughter working levels in eastern Pennsylvania

    International Nuclear Information System (INIS)

    Stebbings, J.H.; Dignam, J.J.; Anast, G.A.; Reilly, M.A.; Gerusky, T.M.; Hartman, T.T.

    1988-01-01

    Working levels (WL) of radon daughters and γ measurements in basements are described for ∼ 1200 houses near the Reading Prong. House variables included condition and construction materials of basement floors and walls, basement heights and areas, heating systems, air conditioning, water supply, and presence of drains and sump pumps. WLs were poorly predicted by house characteristics or γ measurements, while γ levels were well predicted by house characteristics and WL. Factors predicting high γ levels tended to be associated with low WLs and vice versa. Dirt basement floors and fieldstone basement walls were strongly associated with high γ levels, as were poor wall conditions in multivariate analyses. Gamma levels were low in electrically heated homes. High WLs were strongly associated with electric heat, low WLs with basement walls of fieldstone and/or in poor condition. Large house volumes and well water supply were also associated with higher WLs. (author)

  9. Experimental Research on Vibrations of Double Harmonic Gear Transmission

    Directory of Open Access Journals (Sweden)

    Sava Ianici

    2017-11-01

    Full Text Available Gears transmission can be important sources of vibration in the mechanical system structures and can have a significant share in the overall vibration level. The current trend of significant increase in powers and speeds transmitted by modern mechanical systems, along with the size reduction, may cause a worsening of the behaviour of transmissions with gears in terms of vibration, especially when the optimization criteria were not respected in the design, execution and installation phase. This paper presents a study of vibrations that occur in a double harmonic gear transmission (DHGT, based on experimental research. The experimental researches revealed that in a double harmonic gear transmission the vibrations are initiated and develop in the multipara harmonics engagement of the teeth and in the kinematic couplings materialized between the wave generator and the flexible toothed wheel. These vibrations are later transmitted by means of the shafts and bearings to the transmission housing, respectively, through the walls of it, propagating in the air.

  10. Welding distortion control in double walled KSTAR vacuum vessel fabrication

    International Nuclear Information System (INIS)

    Oh, D. W.; Lee, G. T.; Kim, H. K.; Yang, H. L.; Bak, J. S.

    2004-01-01

    The KSTAR(Korea Superconducting Tokamak Advanced Research) vacuum vessel is designed to be a double walled structure made of 12mm thick 316LN stainless steel with a D shaped cross-section about 4 m height. Vacuum vessel was pre-fabricated in two parts, 180 degree and 157.5 degree sectors in toroidal direction to meet the transportation purpose. These two parts have to be welded on site with ±2mm allowable fabrication tolerances. 1/3 scaled mock-up model was used to estimate the welding distortion and to ensure the weld quality of vacuum vessel. Gas Tungsten Arc Welding(GTAW), which has been approved by procedure qualification test, was used during mock-up test and vacuum vessel site fabrication. Welding distortion could be managed by allowing for distortion in opposite direction, by applying high restraint using lots of strong backs, by controlling the welding heat input with symmetrical welding sequence. The integrity of the site welding joint was assured by radiographic test, ultrasonic test and leak test with helium detecting method

  11. Solar Walls in tsbi3

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne

    tsbi3 is a user-friendly and flexible computer program, which provides support to the design team in the analysis of the indoor climate and the energy performance of buildings. The solar wall module gives tsbi3 the capability of simulating solar walls and their interaction with the building....... This version, C, of tsbi3 is capable of simulating five types of solar walls say: mass-walls, Trombe-walls, double Trombe-walls, internally ventilated walls and solar walls for preheating ventilation air. The user's guide gives a description of the capabilities and how to simulate solar walls in tsbi3....

  12. Radial breathing vibration of double-walled carbon nanotubes subjected to pressure

    International Nuclear Information System (INIS)

    Lei, Xiao-Wen; Natsuki, Toshiaki; Shi, Jin-Xing; Ni, Qing-Qing

    2011-01-01

    A theoretical vibrational analysis of the radial breathing mode (RBM) of double-walled carbon nanotubes (DWCNTs) subjected to pressure is presented based on an elastic continuum model. The results agree with reported experimental results obtained under different conditions. Frequencies of the RBM in DWCNTs subjected to increasing pressure depend strongly on circumferential wave numbers, but weakly on the aspect ratio and axial half-wave numbers. For the inner and outer tubes of DWCNTs, the frequency of the RBM increases obviously as the pressure increases under different conditions. The range of variation is smaller for the inner tube than the outer tube. -- Highlights: → An elastic continuum model is used in the theoretical analysis of RBM of DWCNTs. → The RBM of DWCNTs subjected to pressure is analyzed. → Frequency of RBM depends on wave number and aspect ratio. → Frequencies of RBM in inner and outer tubes change in different trends and ranges.

  13. GREEN CORE HOUSE

    Directory of Open Access Journals (Sweden)

    NECULAI Oana

    2017-05-01

    Full Text Available The Green Core House is a construction concept with low environmental impact, having as main central element a greenhouse. The greenhouse has the innovative role to use the biomass energy provided by plants to save energy. Although it is the central piece, the greenhouse is not the most innovative part of the Green Core House, but the whole building ensemble because it integrates many other sustainable systems as "waste purification systems", "transparent photovoltaic panels" or "double skin façades".

  14. Low energy housing in Ticino - The 'Vitali-Velti' house

    Energy Technology Data Exchange (ETDEWEB)

    Pahud, D.; Generelli, M. [SUPSI-DCT/LEEE-UREC, Trevano-Canobbio (Switzerland); Velti, A; Vitali, B. [architetto, Monte Carasso (Switzerland)

    2003-02-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at work done concerning low energy consumption housing in southern Switzerland. Thanks to large windows in the south-east facade and a well insulated building envelope, the passive solar gains are quoted as providing significant contributions to heating. The remaining heating requirements are covered by a closed fireplace and an electric radiator. Heat is distributed by free convection inside the house, A double-flux ventilation system with heat recovery ensures air renewal (3 volumes per day). Each house has a solar hot water system with electric auxiliary energy supply. Space heating requirements are discussed and compared with the standard values as defined in Swiss energy standards and the conventional auxiliary space heating energy required for the houses is noted.

  15. Deposition Time and Thermal Cycles of Fabricating Thin-wall Steel Parts by Double Electrode GMAW Based Additive Manufacturing

    Directory of Open Access Journals (Sweden)

    Yang Dongqing

    2017-01-01

    Full Text Available The deposition time for fabricating the thin-wall part as well as the peak temperature of the substrate during the process was analyzed in the double electrode gas metal arc welding (DE-GMAW based additive manufacturing (AM. The total deposition time and the interlayer idle time of the manufacturing process decreased with the increasing of the bypass current under the same interlayer temperature and the same deposition rate. The thermal cycling curves illustrated that the peak temperature of the substrate was lower in the DE-GMAW base AM under the same conditions. When depositing the thin-wall parts, the DE-GMAW based AM can reduce the heat input to the substrate and improve the fabrication efficiency, compared with the GMAW based AM.

  16. Spontaneous and controlled-diameter synthesis of single-walled and few-walled carbon nanotubes

    Science.gov (United States)

    Inoue, Shuhei; Lojindarat, Supanat; Kawamoto, Takahiro; Matsumura, Yukihiko; Charinpanitkul, Tawatchai

    2018-05-01

    In this study, we explored the spontaneous and controlled-diameter growth of carbon nanotubes. We evaluated the effects of catalyst density, reduction time, and a number of catalyst coating on the substrate (for multi-walled carbon nanotubes) on the diameter of single-walled carbon nanotubes and the number of layers in few-walled carbon nanotubes. Increasing the catalyst density and reduction time increased the diameters of the carbon nanotubes, with the average diameter increasing from 1.05 nm to 1.86 nm for single-walled carbon nanotubes. Finally, we succeeded in synthesizing a significant double-walled carbon nanotube population of 24%.

  17. House characteristics associated with gamma radiation and radon daughter working levels in eastern Pennsylvania

    International Nuclear Information System (INIS)

    Stebbings, J.H.; Dignam, J.J.; Reilly, M.A.; Gerusky, T.M.; Hartman, T.T.; Anast, G.A.

    1987-01-01

    Working levels (WL) of radon daughters and γ measurements in basements are described for ∼1200 houses near the Reading Prong. House variables studied included condition and construction materials of basement floors and walls, basement heights and areas, heating systems, air conditioning, water supply, and presence of drains and sump pumps. WL's were poorly predicted by house characteristics or γ measurements, while γ levels were well predicted by house characteristics and WL. Except for windowless basements, associated with both high γ andl high WL measurements, factors predicting high γ levels tended to be associated with low WL's and vice versa. Dirt basement floors and fieldstone basement walls were strongly associated with high γ levels, as were poor wall conditions in multivariate analyses. Gamma levels were low in electrically heated homes. High WL's were strongly associated with electric heat, low WL's with basement walls of fieldstone and/or in poor condition. Large house volumes and well water supply were also associated with higher WL's. 4 refs., 1 fig., 4 tabs

  18. Double-wall IFR cell for conditioning intense relativistic electron beams

    International Nuclear Information System (INIS)

    Myers, M.C.; Meger, R.A.; Murphy, D.P.; Fernsler, R.F.; Hubbard, R.F.; Slinker, S.P.; Weidman, D.J.

    1994-01-01

    An intense relativistic electron beam (IREB) injected into neutral gas in the high pressure regime characteristically propagates in a self-pinched mode but is susceptible to the resistive hose instability. Typically, beam are conditioned for propagation experiments by reducing the perturbations that may excite resistive hose and by adjusting the emittance profile of the beam such that the convective growth of the instability is decreased. The former has been achieved by applying an anharmonic focusing force as the beam is transported through a conducting tube or cell. The latter has been effectively demonstrated by passing the beam through an ion focus regime (IFR) cell which imposes a head to tail beam emittance variations. However, since the physical parameters of the two types of cells are different, conflicts arise when the cells are coupled sequentially. The double-wall IFR cell described here eliminates these interface difficulties by providing the necessary conditions properties in a single cell. The physics and design of the cell will be introduced and parameter variations explored. The conditioning and propagation measurements will be presented and the results of the experiment will be discussed in relation to theory and simulation

  19. A comparative analysis of double inversion recovery TFE and TSE sequences on carotid artery wall imaging

    International Nuclear Information System (INIS)

    Chen Jun; Di Yujin; Bu Chunqing; Zhang Yanfeng; Li Shuhua

    2012-01-01

    Objective: To analyze the characteristics of double inversion recovery (DIR) turbo field echo (TFE) and turbo spin echo (TSE) sequences and explore the value of double inversion recovery TFE sequence on carotid artery wall imaging. Patients and methods: 56 patients (32 males and 24 females, aged 31–76 years with a mean age of 53 years) were performed with DIR TFE and DIR TSE T1 weighted imaging (T1WI) sequences on carotid artery bifurcations. Image quality acquired by different techniques were evaluated and scored by two physicians. Whether there is significant difference is determined by SPSS 11.0 software. Paired-samples t test was used for statistics. Results: There was no significant difference in the image quality scores between two sequences (t = 0.880, P = 0.383 > 0.05). Conclusions: DIR TFE sequence has short scanning time and high spatial resolution. DIR TFE sequence can be used as the preferred sequence for screening carotid atherosclerotic plaque compared with DIR TSE sequence.

  20. Uranium City radiation reduction program: further efforts at remedial measures for houses with block walls, concrete porosity test results, and intercomparison of Kuznetz method and Tsivoglau method

    International Nuclear Information System (INIS)

    Haubrich, E.; Leung, M.K.; Mackie, R.

    1980-01-01

    An attempt was made to reduce the levels of radon in a house in Uranium City by mechanically venting the plenums in the concrete block basement walls, with little success. A table compares the results obtained by measuring the radon WL using the Tsivoglau and the Kuznetz methods

  1. Real-time remote-controlled welding of the inspection nozzle on the Phenix double-wall tank

    Energy Technology Data Exchange (ETDEWEB)

    Chagnot, C.; Dineghin, G. de; Baude, D.; Delmas, A.; Gauthier, A. [CEA Saclay, Lab. Moderne de Soudage, 91 - Gif sur Yvette (France); Gros, J. [Centrale Phenix, 30 - Bagnols sur Ceze (France); Sommeillier, M. [Comex Nucleaire, 13 - Marseille (France)

    2001-07-01

    For the ultrasonic non destructive inspection of the vessel shell ring welds in the Phenix reactor, the insert of the NDT instrument needs to drill the double-wall tank, to install and weld nozzles. This last operation is realized by the way of an orbital welding installation. Considering severe environment restraints (irradiation, temperature, space,...), the welding control is made at distance (50 m). To supervise this operation, the welder requires an high quality image of the welding scene. Five nozzles of about 400 mm diameter are distributed on a 12 m-diameter tank. The junction between the nozzle and the tank present a shape of horse saddle and the passes trajectories against the tank wall show a lateral deviation of several millimeters. To take care of this deviation and of eventual geometrical defects, the welder adjust the torch position during welding. For that he needs an adapted information. The ''Laboratoire Moderne de Soudage'' inside CEA/CEREM has designed, validated and provided a new Computer-Assisted Welding for real-time remote-controlled orbital welding. Video cameras and a laser diode module were installed on the orbital installation for the watching of the welding scene. An image processing unit of new generation gives the real-time measurement of the distance between the torch and the wall tank. The control of the torch position is particularly significant to guarantee the good welding pass sequence. With this system, the position precision can reach 0,1 mm. (author)

  2. Real-time remote-controlled welding of the inspection nozzle on the Phenix double-wall tank

    International Nuclear Information System (INIS)

    Chagnot, C.; Dineghin, G. de; Baude, D.; Delmas, A.; Gauthier, A.; Gros, J.; Sommeillier, M.

    2001-01-01

    For the ultrasonic non destructive inspection of the vessel shell ring welds in the Phenix reactor, the insert of the NDT instrument needs to drill the double-wall tank, to install and weld nozzles. This last operation is realized by the way of an orbital welding installation. Considering severe environment restraints (irradiation, temperature, space,...), the welding control is made at distance (50 m). To supervise this operation, the welder requires an high quality image of the welding scene. Five nozzles of about 400 mm diameter are distributed on a 12 m-diameter tank. The junction between the nozzle and the tank present a shape of horse saddle and the passes trajectories against the tank wall show a lateral deviation of several millimeters. To take care of this deviation and of eventual geometrical defects, the welder adjust the torch position during welding. For that he needs an adapted information. The ''Laboratoire Moderne de Soudage'' inside CEA/CEREM has designed, validated and provided a new Computer-Assisted Welding for real-time remote-controlled orbital welding. Video cameras and a laser diode module were installed on the orbital installation for the watching of the welding scene. An image processing unit of new generation gives the real-time measurement of the distance between the torch and the wall tank. The control of the torch position is particularly significant to guarantee the good welding pass sequence. With this system, the position precision can reach 0,1 mm. (author)

  3. Development of the double-wall-tube steam generator. Evaluation of inner tube leak detection system

    International Nuclear Information System (INIS)

    Teraoku, Takuji; Kisohara, Naoyuki

    1995-01-01

    A double-wall-tube steam generator (DWT-SG) is considered to have possibility of eliminating a secondary heat transport system to realize a reliable and simplified FBR plant. Thus, basic tests for inner/outer tube leak detection and prototypical leak tests by use of the 1MWt DWT-SG model have been performed to evaluate the feasibility of DWT-SG. Their results demonstrated that the inner leak detection system can definitely detect a steam leak from an inner tube flaw. Analyses of the inner tube leak and detection behavior obtained in the 1MWt DWT-SG test enabled to estimate the performance of the inner tube detection system of the commercial DWT-SG system. (author)

  4. Vortex Structure Effects on Impingement, Effusion, and Cross Flow Cooling of a Double Wall Configuration

    Science.gov (United States)

    Ligrani, P. M.

    2018-03-01

    A variety of different types of vortices and vortex structures have important influences on thermal protection, heat transfer augmentation, and cooling performance of impingement cooling, effusion cooling, and cross flow cooling. Of particular interest are horseshoe vortices, which form around the upstream portions of effusion coolant concentrations just after they exit individual holes, hairpin vortices, which develop nearby and adjacent to effusion coolant trajectories, and Kelvin-Helmholtz vortices which form within the shear layers that form around each impingement cooling jet. The influences of these different vortex structures are described as they affect and alter the thermal performance of effusion cooling, impingement cooling, and cross flow cooling, as applied to a double wall configuration.

  5. Applying Bim to Built Heritage with Complex Shapes: the Ice House of Filarete's Ospedale Maggiore in Milan, Italy

    Science.gov (United States)

    Oreni, D.; Karimi, G.; Barazzetti, L.

    2017-08-01

    This paper presents the development of a BIM model for a stratified historic structure characterized by a complex geometry: Filarete's Ospedale Maggiore ice house, one of the few remaining historic ice houses in Milan (Fig. 1). Filarete, a well-known Renaissance architect and theorist, planned the hospital in the 15th century, but the ice house was built two centuries later with a double-storey irregular octagonal brick structure, half under and half above ground, that enclosed another circular structure called the ice room. The purpose of the double-walled structure was to store ice in the middle and store and preserve perishable food and medicine at the outer side of the ice room. During World War II, major portions of the hospital and the above-ground section of the ice house was bombed and heavily damaged. Later, in 1962, the hospital was restored and rehabilitated into a university, with the plan to conceal the ice house's remaining structure in the courtyard, which ultimately was excavated and incorporated into a new library for the university. A team of engineers, architects, and students from Politecnico di Milano and Carleton University conducted two heritage recording surveys in 2015 and 2016 to fully document the existing condition of the ice house, resulting in an inclusive laser scanner and photogrammetric point cloud dataset. The point cloud data was consolidated and imported into two leading parametric modelling software, Autodesk Revitand Graphisoft ArchiCAD©, with the goal to develop two BIMs in parallel in order to study and compare the software BIM workflow, parametric capabilities, attributes to capture the complex geometry with high accuracy, and the duration for parametric modelling. The comparison study of the two software revealed their workflow limitations, leading to integration of the BIM generative process with other pure modelling software such as Rhinoceros©. The integrative BIM process led to the production of a comprehensive BIM

  6. Modeling radon entry into Florida slab-on-grade houses

    International Nuclear Information System (INIS)

    Revzan, K.L.; Fisk, W.J.; Sextro, R.G.

    1993-01-01

    Radon entry into a Florida house whose concrete slab is supported by a permeable concrete-block stem wall and a concrete footer is modeled. The slab rests on backfill material; the same material is used to fill the footer trench. A region of undisturbed soil is assumed to extend 10 m beyond and below the footer. The soil is assumed homogeneous and isotropic except for certain simulations in which soil layers of high permeability or radium content are introduced. Depressurization of the house induces a pressure field in the soil and backfill. The Laplace equation, resulting from Darcy's law and the continuity equation, is solved using a steady-state finite-difference model to determine this field. The mass-transport equation is then solved to obtain the diffusive and advective radon entry rates through the slab; the permeable stem wall; gaps at the intersections of the slab, stem wall, and footer; and gaps in the slab. These rates are determined for variable soil, backfill, and stem-wall permeability and radium content, slab-opening width and position, slab and stem-wall diffusivity, and water table depth. The variations in soil permeability and radium content include cases of horizontally stratified soil. We also consider the effect of a gap between the edge of the slab and the stem wall that restricts the passage of soil gas from the stem wall into the house. Calculations indicate that the total radon entry rate is relatively low unless the soil or backfill permeability or radium content is high. Variations in most of the factors, other than the soil permeability and radium content, have only a small effect on the total radon entry rate. However, for a fixed soil permeability, the total radon entry rate may be reduced by a factor of 2 or more by decreasing the backfill permeability, by making the stem wall impermeable and gap-free, (possibly by constructing a one-piece slab/stem-wall/footer), or by increasing the pressure in the interior of the stem wall

  7. Construction of a self-supporting tissue-equivalent dividing wall and operational characteristics of a coaxial double-cylindrical tissue-equivalent proportional counter

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.

    1994-01-01

    An additional feature incorporated in a coaxial double-cylindrical tissue-equivalent proportional counter, is the presence of a common tissue-equivalent dividing wall between the inner and outer counters of thickness equivalent to the corresponding maximum range of protons at the energy of interest. By appropriate use of an anti-coincidence arrangement with the outer counter, the inner counter could be used to discriminate microdosimetric spectra of neutrons at the desired low energy range from those of the faster neutrons. The construction of an A-150 self-supporting tissue-equivalent dividing wall and an anti-coincidence unit are described. Some operational characteristic tests have been performed to determine the operation of the new microdosimeter. (author)

  8. Families experiencing housing instability: the effects of housing programs on family routines and rituals.

    Science.gov (United States)

    Mayberry, Lindsay Satterwhite; Shinn, Marybeth; Benton, Jessica Gibbons; Wise, Jasmine

    2014-01-01

    Maintenance of family processes can protect parents, children, and families from the detrimental effects of extreme stressors, such as homelessness. When families cannot maintain routines and rituals, the stressors of poverty and homelessness can be compounded for both caregivers and children. However, characteristics of living situations common among families experiencing homelessness present barriers to the maintenance of family routines and rituals. We analyzed 80 in-depth interviews with parents who were experiencing or had recently experienced an instance of homelessness. We compared their assessments of challenges to family schedules, routines, and rituals across various living situations, including shelter, transitional housing programs, doubled-up (i.e., living temporarily with family or friends), and independent housing. Rules common across shelters and transitional housing programs impeded family processes, and parents felt surveilled and threatened with child protective service involvement in these settings. In doubled-up living situations, parents reported adapting their routines to those of the household and having parenting interrupted by opinions of friends and family members. Families used several strategies to maintain family routines and rituals in these living situations and ensure consistency and stability for their children during an otherwise unstable time. (c) 2014 APA, all rights reserved.

  9. Nonlinear vibration of double-walled boron nitride and carbon nanopeapods under multi-physical fields with consideration of surface stress effects

    Science.gov (United States)

    Ghorbanpour Arani, A.; Sabzeali, M.; BabaAkbar Zarei, H.

    2017-12-01

    In this study, the nonlinear thermo-electro vibrations of double-walled boron nitride nanopeapods (DWBNNPPs) and double-walled carbon nanopeapods (DWCNPPs) under magnetic field embedded in an elastic medium is investigated. DWBNNPPs are made of piezoelectric and smart materials therefore, electric field is effective on them; meanwhile, DWCNPPs are made of carbon thus, magnetic field can be useful to control them. The Pasternak model is used to simulate the effects of elastic medium which surrounds the system. Nanotubes are modeled with assumption of the Euler-Bernoulli beam (EBB) theory and the surface effects are considered to achieve accurate response of the system. Moreover, interaction between two layers is modeled by van der Waals (vdW) forces. The equations of motion are derived using the energy method and the Hamilton principle. Then the governing equations are solved by using Galerkin's method and incremental harmonic balance method (IHBM). The influences of various parameters such as the magnetic field, different types of DWCNPPs and DWBNNPPs, elastic medium, existence of fullerene and surface effect on the vibration behavior of the system are investigated. The results demonstrate that DWBNNPPs have more influence on the frequency of the system than DWCNPPs. In addition, the presence of fullerene in nanotubes has a negative impact on the frequency behavior of revisionthe system.

  10. Sonoma House. Monitoring of the First U.S. Passive House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles that promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  11. Sonoma House: Monitoring of the First U.S. Passive House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A.; Weitzel, B.; Backman, C.; Hoeschele, M.; Dakin, B.

    2012-12-01

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles which promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  12. Analytical solutions to the free vibration of a double-walled carbon nanotube carrying a bacterium at its tip

    Energy Technology Data Exchange (ETDEWEB)

    Storch, Joel A. [Department of Mechanical Engineering, California State University, Northridge, CA 91330-8348 (United States); Elishakoff, Isaac [Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL 33431-0991 (United States)

    2013-11-07

    We calculate the natural frequencies and mode shapes of a cantilevered double-walled carbon nanotube carrying a rigid body—representative of a bacterium or virus—at the tip of the outer nanotube. By idealizing the nanotubes as Bernoulli-Euler beams, we are able to obtain exact expressions for both the mode shapes and characteristic frequency equation. Separate analyses are performed for the special case of a concentrated tip mass and the more complicated situation where the tip body also exhibits inertia and mass center offset from the beam tip.

  13. An Innovative Enhanced Wall to Reduce the Energy Demand in Buildings

    Science.gov (United States)

    Fantozzi, F.; Filipeschi, S.; Mameli, M.; Nesi, S.; Cillari, G.; Mantelli, M. B. H.; Milanez, F. H.

    2017-01-01

    Energy saving in buildings is one of most important issues for European countries. Although in the last years many studies have been carried out in order to reach the zero-consumption house the energy rate due to passive solar heating could be further enhanced. This paper proposes a method for increasing the energy rate absorbed by opaque walls by using a two phase loop thermosyphon connecting the internal and the external façade of a prefabricated house wall. The evaporator zone is embedded into the outside facade and the condenser is indoor placed to heat the domestic environment. The thermosyphon has been preliminary designed and implanted into a wall for a prefabricated house in Italy. An original dynamic thermal model of the building equipped with the thermosyphon wall allowed the evolution of the indoor temperature over time and the energy saving rates. The transient behaviour of the building has been simulated during the winter period by using the EnergyPlusTM software. The annual saving on the heating energy is higher than 50% in the case of a low consumption building.

  14. Field Emission Property of Double-walled Carbon Nanotubes Related to Purification and Transmittance

    International Nuclear Information System (INIS)

    Ahn, KiTae; Jang, HyunChul; Hong, Wanshick; Park, Kyoungwan; Sok, Junghyun; Lyu, SeungChul; Lee, Hansung; Lee, Naesung; Han, Moonsup; Park, Yunsun

    2011-01-01

    Double-walled carbon nanotubes (DWCNTs) with high purity were produced by the catalytic decomposition of tetrahydrofuran (THF) using a Fe-Mo/MgO catalyst at 800°C. The as-synthesized DWCNTs typically have catalytic impurities and amorphous carbon, which were removed by a two-step purification process consisting of acid treatment and oxidation. In the acid treatment, metallic catalysts were removed in HCl at room temperature for 5 hr with magnetic stirring. Subsequently, the oxidation, using air at 380°C for 5 hr in the a vertical-type furnace, was used to remove the amorphous carbon particles. The DWCNT suspension was prepared by dispersing the purified DWCNTs in the aqueous sodium dodecyl sulfate solution with horn-type sonication. This was then air-sprayed on ITO glass to fabricate DWCNT field emitters. The field emission properties of DWCNT films related to transmittance were studied. This study provides the possibility of the application of large-area transparent CNT field emission cathodes.

  15. Sharp burnout failure observed in high current-carrying double-walled carbon nanotube fibers

    Science.gov (United States)

    Song, Li; Toth, Geza; Wei, Jinquan; Liu, Zheng; Gao, Wei; Ci, Lijie; Vajtai, Robert; Endo, Morinobu; Ajayan, Pulickel M.

    2012-01-01

    We report on the current-carrying capability and the high-current-induced thermal burnout failure modes of 5-20 µm diameter double-walled carbon nanotube (DWNT) fibers made by an improved dry-spinning method. It is found that the electrical conductivity and maximum current-carrying capability for these DWNT fibers can reach up to 5.9 × 105 S m - 1 and over 1 × 105 A cm - 2 in air. In comparison, we observed that standard carbon fiber tended to be oxidized and burnt out into cheese-like morphology when the maximum current was reached, while DWNT fiber showed a much slower breakdown behavior due to the gradual burnout in individual nanotubes. The electron microscopy observations further confirmed that the failure process of DWNT fibers occurs at localized positions, and while the individual nanotubes burn they also get aligned due to local high temperature and electrostatic field. In addition a finite element model was constructed to gain better understanding of the failure behavior of DWNT fibers.

  16. Thermodynamics for the Formation of Double-Stranded DNA-Single-Walled Carbon Nanotube Hybrids.

    Science.gov (United States)

    Shiraki, Tomohiro; Tsuzuki, Akiko; Toshimitsu, Fumiyuki; Nakashima, Naotoshi

    2016-03-24

    For the first time, the thermodynamics are described for the formation of double-stranded DNA (ds-DNA)-single-walled carbon nanotube (SWNT) hybrids. This treatment is applied to the exchange reaction of sodium cholate (SC) molecules on SWNTs and the ds-DNAs d(A)20 -d(T)20 and nuclear factor (NF)-κB decoy. UV/Vis/near-IR spectroscopy with temperature variations was used for analyzing the exchange reaction on the SWNTs with four different chiralities: (n,m)=(8,3), (6,5), (7,5), and (8,6). Single-stranded DNAs (ss-DNAs), including d(A)20 and d(T)20, are also used for comparison. The d(A)20-d(T)20 shows a drastic change in its thermodynamic parameters around the melting temperature (Tm ) of the DNA oligomer. No such Tm dependency was measured, owing to high Tm in the NF-κB decoy DNA and no Tm in the ss-DNA. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Effectiveness of multi-stage scrubbers in reducing emissions of air pollutants from pig houses

    OpenAIRE

    Zhao, Y.; Aarnink, A.J.A.; Jong, de, M.C.M.; Ogink, N.W.M.; Groot Koerkamp, P.W.G.

    2011-01-01

    Emissions of air pollutants from livestock houses may raise environmental problems and pose hazards to public health. They can be reduced by scrubbers installed at the air outlets of livestock houses. In this study, three multi-stage scrubbers were evaluated in terms of their effectiveness in reducing emissions of airborne dust, total bacteria, ammonia, and CO2 from pig houses in winter. The three multi-stage scrubbers were one double-stage scrubber (acid stage+ bio-filter), one double-stage ...

  18. Preliminary Analysis of Reinforced Concrete Waffle Walls

    National Research Council Canada - National Science Library

    Shugar, Theodore

    1997-01-01

    A preliminary analytical method based upon modified plate bending theory is offered for structural analysis of a promising new construction method for walls of small buildings and residential housing...

  19. Building Structure Housing: Case Study of Community Housing in Kendari City

    Science.gov (United States)

    Umar, M. Z.; Faslih, A.; Arsyad, M.; Sjamsu, A. S.; Kadir, I.

    2017-11-01

    Housing development has been pioneered through a simple home construction program to reduce the production cost. Simple housing program was developed in Kendari City. The purpose of this study is to show the principles of reducing the cost production for the type 36 homes, in Kendari City. The selected architectural objects are the lower, middle and the upper structure of type 36 house. The data collection was done by observation and in-depth discussion with construction workers. The analysis technique used in this research was a descriptive narrative analysis technique in the form of tabulation data. This study concluded that there are several principles of price reduction in the structure of public housing buildings. Quick principles exist in constructing techniques such as using cigarette packs as a foundation pad, mortar usage for rapid wall standing, and the spacing of mortars could be done manually by using two fingers on a human hand. Economic principles could be used for material matters, such as eliminating the use of gravel for concrete, the use of sand material to contain the soil, the foundation does not use sand and empty stone, and the shape of the ring beam was made using triangle reinforcement.

  20. Nanomaterial Containing Wall Paints Can Increase Radon Concentration in Houses Located in Radon Prone Areas Haghani M.2 , Mortazavi S. M. J.1, 2*, Faghihi R.3, Mehdizadeh S.3, Moradgholi J.4, Darvish L.5, Fathi-Pour E.5, Ansari L.5, Ghanbar-pour M. R.3 1The Center for Radiological Research, Shiraz University of Medical Sciences, Shiraz, Iran 2Department of Med

    Directory of Open Access Journals (Sweden)

    Haghani M.

    2013-09-01

    Full Text Available Background: Nowadays, extensive technological advancements have made it possible to use nanopaints which show exciting properties. In IR Iran excessive radon levels (up to 3700 Bq m–3 have been reported in homes located in radon prone areas. Over the past decades, concerns have been raised about the risk posed by residential radon exposure. Objective: This study aims at investigating the effect of using nanomaterial containing wall paints on radon concentration in homes. Methods: Two wooden model houses were used in this study. Soil samples from Ramsar high background radiation areas were used for simulating the situation of a typical house in radon-prone areas. Conventional water-soluble wall paint was used for painting the walls of the 1st house model; while the 2nd house model was painted with the same wall paint with montmorillonite nanoclay. Results: Three days after sealing the house models, radon level was measured by using a portable radon survey meter. The mean radon level inside the 1st house model (conventional paint was 515.3 ± 17.8 Bq/m3 while the mean radon concentration in the 2nd house model (nano-painted house model was 570.8 ± 18.5 Bq/m3. The difference between these means was statistically signifcant (P<0.001. Conclusion: To the best of our knowledge, this study is the frst investigation on the effect of nano-material containing wall paints on indoor radon concentrations. It can be concluded that nano-material-containing wall paints should not be used in houses with wooden walls located in radon prone areas. Although the mechanism of this effect is not clearly known, decreased porosity in nano-paints might be a key factor in increasing the radon concentration in homes.

  1. Improving Station Performance by Building Isolation Walls in the Tunnel

    Science.gov (United States)

    Jia, Yan; Horn, Nikolaus; Leohardt, Roman

    2014-05-01

    Conrad Observatory is situated far away from roads and industrial areas on the Trafelberg in Lower Austria. At the end of the seismic tunnel, the main seismic instrument of the Observatory with a station code CONA is located. This station is one of the most important seismic stations in the Austrian Seismic Network (network code OE). The seismic observatory consists of a 145m long gallery and an underground laboratory building with several working areas. About 25 meters away from the station CONA, six temporary seismic stations were implemented for research purposes. Two of them were installed with the same equipment as CONA, while the remaining four stations were set up with digitizers having lower noise and higher resolution (Q330HR) and sensors with the same type (STS-2). In order to prevent possible disturbances by air pressure and temperature fluctuation, three walls were built inside of the tunnel. The first wall is located ca 63 meters from the tunnel entrance, while a set of double walls with a distance of 1.5 meters is placed about 53 meters from the first isolation wall but between the station CONA and the six temporary stations. To assess impact of the isolation walls on noise reduction and detection performance, investigations are conducted in two steps. The first study is carried out by comparing the noise level and detection performance between the station CONA behind the double walls and the stations in front of the double walls for verifying the noise isolation by the double walls. To evaluate the effect of the single wall, station noise level and detection performance were studied by comparing the results before and after the installation of the wall. Results and discussions will be presented. Additional experiment is conducted by filling insulation material inside of the aluminium boxes of the sensors (above and around the sensors). This should help us to determine an optimal insulation of the sensors with respect to pressure and temperature

  2. Conceptual Design and Feasibility Analyses of a Robotic System for Automated Exterior Wall Painting

    Directory of Open Access Journals (Sweden)

    Young S. Kim

    2008-11-01

    Full Text Available There are approximately 6,677,000 apartment housing units in South Korea. Exterior wall painting for such multi-dwelling apartment housings in South Korea represents a typical area to which construction automation technology can be applied for improvement in safety, productivity, quality, and cost over the conventional method. The conventional exterior wall painting is costly and labor-intensive, and it especially exposes workers to significant health and safety risks. The primary objective of this study is to design a conceptual model of an exterior wall painting robot which is applicable to apartment housing construction and maintenance, and to conduct its technical?economical feasibility analyses. In this study, a design concept using a high ladder truck is proposed as the best alternative for automation of the exterior wall painting. Conclusions made in this study show that the proposed exterior wall painting robot is technically and economically feasible, and can greatly enhance safety, productivity, and quality compared to the conventional method. Finally, it is expected that the conceptual model of the exterior wall painting robot would be efficiently used in various applications in exterior wall finishing and maintenance of other architectural and civil structures such as commercial buildings, towers, and high-rise storage tanks.

  3. EFFECTIVE KEYED CONNECTIONS OF HOLLOW-CORE FLOOR SLABS WITH WALLS IN MODERN LARGE-PANEL HOUSE BUILDING

    Directory of Open Access Journals (Sweden)

    O. A. Dovzhenko

    2018-01-01

    Full Text Available The paper considers large-panel constructive system of multi-storey buildings and its industrial basis creates conditions for intensive volume growth in house construction. Application of hollow-core panels are recommended as floor slabs that allows to increase a distance between bearing walls, to improve planning solutions, and also significantly to increase thermal and sound protection properties of floor discs (coatings. Keyed joints having the highest resistance to shearing forces are used to ensure joint action of the slabs with wall panels. A supporting unit of floor elements in the precast-monolithic constructive system ARKOS by means of concrete keys is considered as a prototype of the considered joint. In order to increase a bearing capacity and improve reliability of joints it is envisaged to reinforce keys with space frames. Improvement of joint units is possible to carry out with due account of total number of the factors influencing on strength. Poltava National Technical University named after Yuri Kondratyuk has developed a general methodology for assessment of bearing capacity in keyed joints which is based on the variational method in the theory of concrete plasticity and reflects specificity of stress-strain state of the failure zone. For experimental verification of this methodology investigations have been carried out with the purpose to test operation of keys when they are reinforced in mid-height and reinforcement is distributed in two tiers. The observed experimental fracture pattern in the specimens has confirmed kinematic schemes accepted for calculations and comparative analysis of experimental and theoretical values points to their closeness. Two-level reinforcement significantly improves plastic properties of concrete keys and excludes brittle failure. The proposed design of the joint unit for floor slabs with wall panels is characterized by the ratio of key dimensions and shape of reinforcing cages in the form of

  4. House Price Forecasts, Forecaster Herding, and the Recent Crisis

    DEFF Research Database (Denmark)

    Stadtmann, Georg; Pierdzioch; Ruelke

    2013-01-01

    We used the Wall Street Journal survey data for the period 2006–2012 to analyze whether forecasts of house prices and housing starts provide evidence of (anti-)herding of forecasters. Forecasts are consistent with herding (anti-herding) of forecasters if forecasts are biased towards (away from) t......) the consensus forecast. We found that anti-herding is prevalent among forecasters of house prices. We also report that, following the recent crisis, the prevalence of forecaster anti-herding seems to have changed over time....

  5. Strategy Guideline: Modeling Enclosure Design in Above-Grade Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, J. [Building Science Corporation, Westford, MA (United States); Ueno, K. [Building Science Corporation, Westford, MA (United States); Musunuru, S. [Building Science Corporation, Westford, MA (United States)

    2016-02-24

    The Strategy Guideline describes how to model and interpret results of models for above grade walls. The Measure Guideline analyzes the failure thresholds and criteria for above grade walls. A library of above-grade walls with historically successful performance was used to calibrate WUFI (Warme Und Feuchte Instationar) software models. The information is generalized for application to a broad population of houses within the limits of existing experience.

  6. Measuremental analysis of thermal performance of direct gain houses in Kanto district. Effects of thermal mass and caves; Kanto chiho ni tatsu direct gain jutaku no netsuseino jissoku. Netsuyoryo to hisashi no koka

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, K; Sunaga, N; Muro, K [Tokyo Metropolitan University, Tokyo (Japan)

    1996-10-27

    The thermal performance of direct gain passive solar houses was measured. Mr. M`s two-storied RC residence with double glazing windows and thermal storage floors, walls and ceilings of brick or concrete was provided for measurement. Its double eaves of the south window and both SE and SW overhanging exterior walls play a role in sunshade. Mr. I`s two-storied wooden residence with thermal storage RC floors and brick walls, and no eaves of the south window and no overhanging exterior walls was also provided. The summer and winter measurement results were in complete contrast between the residences. In summer, large thermal mass and eaves of Mr. M`s residence were effective, while in winter, small thermal mass and no eaves of Mr. I`s residence were effective. The following ideas are important in design from the viewpoint of indoor thermal environment: a movable sunshade for taking in solar radiation as much as possible in winter, well-balanced arrangement of thermal storage parts with suitable thermal mass corresponding to movement of the sun, a large screen door for cross ventilation in summer, and a night insulation shutter for reducing heat loss in winter. 2 refs., 10 figs., 1 tab.

  7. Enhanced field emission properties of vertically aligned double-walled carbon nanotube arrays

    International Nuclear Information System (INIS)

    Chen, Guohai; Shin, Dong Hoon; Lee, Cheol Jin; Iwasaki, Takayuki; Kawarada, Hiroshi

    2008-01-01

    Vertically aligned double-walled carbon nanotube (VA-DWCNT) arrays were synthesized by point-arc microwave plasma chemical vapor deposition on Cr/n-Si and SiO 2 /n-Si substrates. The outer tube diameters of VA-DWCNTs are in the range of 2.5-3.8 nm, and the average interlayer spacing is approximately 0.42 nm. The field emission properties of these VA-DWCNTs were studied. It was found that a VA-DWCNT array grown on a Cr/n-Si substrate had better field emission properties as compared with a VA-DWCNT array grown on a SiO 2 /n-Si substrate and randomly oriented DWCNTs, showing a turn-on field of about 0.85 V μm -1 at the emission current density of 0.1 μA cm -2 and a threshold field of 1.67 V μm -1 at the emission current density of 1.0 mA cm -2 . The better field emission performance of the VA-DWCNT array was mainly attributed to the vertical alignment of DWCNTs on the Cr/n-Si substrate and the low contact resistance between CNTs and the Cr/n-Si substrate

  8. Double Walled Carbon Nanotube/TiO2 Nanocomposites for Photocatalytic Dye Degradation

    Directory of Open Access Journals (Sweden)

    Alex T. Kuvarega

    2016-01-01

    Full Text Available Double walled carbon nanotube (DWCNT/N,Pd codoped TiO2 nanocomposites were prepared by a modified sol-gel method and characterised using FTIR, Raman spectroscopy, TGA, DRUV-Vis, XRD, SEM, and TEM analyses. TEM images showed unique pearl-bead-necklace structured morphologies at higher DWCNT ratios. The nanocomposite materials showed characteristic anatase TiO2 Raman bands in addition to the carbon nanotube D and G bands. Red shifts in the UV-Vis absorption edge were observed at low DWCNT percentages. The photocatalytic activity of DWCNT/N,Pd TiO2 nanocomposite was evaluated by the photocatalytic degradation of eosin yellow under simulated solar light irradiation and the 2% DWCNT/N,Pd TiO2 nanocomposite showed the highest photoactivity while the 20% DWCNT/N,Pd TiO2 hybrid was the least efficient. The photocatalytic enhancement was attributed to the synergistic effects of the supporting and electron channeling role of the DWCNTs as well as the electron trapping effects of the platinum group metal. These phenomena favour the separation of the photogenerated electron-hole pairs, reducing their recombination rate, which consequently lead to significantly enhanced photoactivity.

  9. Kinetic wall from Israel

    Energy Technology Data Exchange (ETDEWEB)

    Godolphin, D.

    1985-05-01

    An unusual solar mass wall is described. At the turn of a handle it can change from a solar energy collector to a heat-blocker. An appropriate name for it might be the rotating prism wall. An example of the moving wall is at work in an adobe test home in Sede Boqer. Behind a large south-facing window stand four large adobe columns that are triangular in plan. One face of each of them is painted black to absorb sunlight, a second is covered with panels of polystyrene insulation, and a third is painted to match the room decor. These columns can rotate. On winter nights, the insulated side faces the glass, keeping heat losses down. The same scheme works in summer to keep heat out of the house. Small windows provide ventilation.

  10. House Price Forecasts, Forecaster Herding, and the Recent Crisis

    Directory of Open Access Journals (Sweden)

    Christian Pierdzioch

    2012-11-01

    Full Text Available We used the Wall Street Journal survey data for the period 2006–2012 to analyze whether forecasts of house prices and housing starts provide evidence of (anti-herding of forecasters. Forecasts are consistent with herding (anti-herding of forecasters if forecasts are biased towards (away from the consensus forecast. We found that anti-herding is prevalent among forecasters of house prices. We also report that, following the recent crisis, the prevalence of forecaster anti-herding seems to have changed over time.

  11. Evolution Sustainable Green Inner-wall with Flexible Floor Plan

    OpenAIRE

    Tawil N.M.; Hussaini H. A.; Basri H.; Che Ani A. I.; Mydin M.A.O

    2014-01-01

    The trend of renovate residential houses especially the interior of the house has become a common phenomenon for homeowners nowadays in Malaysia. This scenario is quiet concern because sometimes no modifications to comply with the law and the guidelines set by the government housing. Modifications with not done properly can cause injury and harm to families and the people around. To reduce this problem, the concept of sustainable inner walls with flexible floor plan should be incorporated in ...

  12. The impact of thermal bridges on the energy demand of buildings with double brick wall constructions

    Energy Technology Data Exchange (ETDEWEB)

    Theodosiou, T.G. [Department of Engineering and Management of Energy Resources, University of Western Macedonia, GR-50100 Kozani (Greece); Papadopoulos, A.M. [Laboratory of Heat Transfer and Environmental Engineering, Department of Mechanical Engineering, Aristotle University Thessaloniki, GR-54124 Thessaloniki (Greece)

    2008-07-01

    The implementation of the European Directive on the Energy Performance of Buildings (EPBD) is a milestone towards the improvement of energy efficiency in the building sector. However, even in cases where impressive measures can be implemented in the densely built urban environment, the less glamorous measure of building's envelope thermal insulation remains a prerequisite towards the improvement of the building's energy efficiency. Despite the insulation requirements specified by national regulations, thermal bridges in the building's envelope remain a weak spot in the constructions. Moreover, in many countries construction practices tend to implement only partially the insulation measures foreseen by regulations. As a result, thermal losses are in practice greater than those predicted during the design stage. This paper presents a study on representative wall thermal insulation configurations used in Greek buildings, in order to investigate the impact of the thermal bridges on the energy consumption. The double wall construction, used widely in Greece and not only there, is rather susceptible to the occurrence of thermal bridges, in contrast to a typical thermal insulating facade, like the one applied in Central Europe. The analysis of the thermal bridges' impact will in that sense also highlight the potential for energy renovation measures in older buildings. (author)

  13. Synthesis of the IRSN report related to the containment of double walled enclosures of the operated fleet

    International Nuclear Information System (INIS)

    2013-01-01

    This report presents the IRSN's analysis on studies and modifications planned by EDF within the frame of the VD3-1300 safety re-examination which more particularly concern the third containment barrier of a reactor and of its extensions, as well as the containment of some surrounding buildings. The addressed topics are: the approach associated with the 'containment' safety function, the condition, behaviour and control of the double walled enclosure, the system of suction and filtration of the space between enclosures, the extension of the third containment barrier, the containment of building surrounding the reactor building, the risk of bypass containment, the EDF organisation with respect to the containment safety function

  14. Unofficial policy: access to housing, housing information and social services among homeless drug users in Hartford, Connecticut

    Directory of Open Access Journals (Sweden)

    Corbett A Michelle

    2007-03-01

    Full Text Available Abstract Background Much research has shown that the homeless have higher rates of substance abuse problems than housed populations and that substance abuse increases individuals' vulnerability to homelessness. However, the effects of housing policies on drug users' access to housing have been understudied to date. This paper will look at the "unofficial" housing policies that affect drug users' access to housing. Methods Qualitative interviews were conducted with 65 active users of heroin and cocaine at baseline, 3 and 6 months. Participants were purposively sampled to reflect a variety of housing statuses including homeless on the streets, in shelters, "doubled-up" with family or friends, or permanently housed in subsidized, unsubsidized or supportive housing. Key informant interviews and two focus group interviews were conducted with 15 housing caseworkers. Data were analyzed to explore the processes by which drug users receive information about different housing subsidies and welfare benefits, and their experiences in applying for these. Results A number of unofficial policy mechanisms limit drug users' access to housing, information and services, including limited outreach to non-shelter using homeless regarding housing programs, service provider priorities, and service provider discretion in processing applications and providing services. Conclusion Unofficial policy, i.e. the mechanisms used by caseworkers to ration scarce housing resources, is as important as official housing policies in limiting drug users' access to housing. Drug users' descriptions of their experiences working with caseworkers to obtain permanent, affordable housing, provide insights as to how access to supportive and subsidized housing can be improved for this population.

  15. Investigation of the adsorption of polymer chains on amine-functionalized double-walled carbon nanotubes.

    Science.gov (United States)

    Ansari, R; Ajori, S; Rouhi, S

    2015-12-01

    Molecular dynamics (MD) simulations were used to study the adsorption of different polymer chains on functionalized double-walled carbon nanotubes (DWCNTs). The nanotubes were functionalized with two different amines: NH2 (a small amine) and CH2-NH2 (a large amine). Considering three different polymer chains, all with the same number of atoms, the effect of polymer type on the polymer-nanotube interaction was studied. In general, it was found that covalent functionalization considerably improved the polymer-DWCNT interaction. By comparing the results obtained with different polymer chains, it was observed that, unlike polyethylene and polyketone, poly(styrene sulfonate) only weakly interacts with the functionalized DWCNTs. Accordingly, the smallest radius of gyration was obtained with adsorbed poly(styrene sulfonate). It was also observed that the DWCNTs functionalized with the large amine presented more stable interactions with polyketone and poly(styrene sulfonate) than with polyethylene, whereas the DWCNTs functionalized with the small amine showed better interfacial noncovalent bonding with polyethylene.

  16. Adsorption of Cadmium Ions from Water on Double-walled Carbon Nanotubes/Iron Oxide Composite

    Directory of Open Access Journals (Sweden)

    Karima Seffah

    2017-12-01

    Full Text Available A new material (DWCNT/iron oxide for heavy metals removal was developed by combining the adsorption features of double-walled carbon nanotubes with the magnetic properties of iron oxides. Batch experiments were applied in order to evaluate adsorption capacity of the DWCNT/iron oxide composite for cadmium ions. The influence of operating parameters such as pH value, amount of adsorbent, initial adsorbate concentration and agitation speed was studied. The adsorption capacity of the DWCNT/iron oxide adsorbent for Cd2+ ions was 20.8 mg g-1, which is at the state of the art. The obtained results revealed that DWCNT/iron oxide composite is a very promising adsorbent for removal of Cd2+ ions from water under natural conditions. The advantage of the magnetic composite is that it can be used as adsorbent for contaminants in water and can be subsequently controlled and removed from the medium by a simple magnetic process.

  17. Double benefit. Passive houses in the stock: Residential and office house; Doppelter Nutzen. Passivhaus im Bestand: Wohn- und Geschaeftshaus

    Energy Technology Data Exchange (ETDEWEB)

    Siegele, Klaus

    2012-06-15

    When searching for a new home for family and office, the Passive House Planner Roland Matzig (Mannheim, Federal Republic of Germany) encounter a dilapidated semi-detached house in Almendorf, a suburb of Mannheim (Federal Republic of Germany). The enhanced final energy demand by more than 320 kWh/(a m{sup 2}) encouraged him, to retrofit the post-war building energetically to the level of a passive houses. The residential and office building also benefits architecturally from the alterations and extensions - a perfect example of how to make of buildings sustainable and to receive their value.

  18. Using Retrofit Nail Base Panels to Expand the Market for Wall Upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M. [Home Innovation Research Lab., Upper Marlboro, MD (United States); Wiehagen, J. [Home Innovation Research Lab., Upper Marlboro, MD (United States)

    2016-02-01

    This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of building air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.

  19. Sustainable green inner-wall design for flexible floor plan

    International Nuclear Information System (INIS)

    Tawil, N M; Husaini, H A; Ani, A I; Saleh, R M; Basri, H

    2013-01-01

    The rises of house price in the market is so drastic that it effects the younger generation nowadays especially young executives and young couples who could not afford to buy their first home. The factors that determine the house price presumably are the interior and exterior structural of the house itself. So to lessen the house price, we have to minimize the usage of wet construction thus the idea of having a sustainable green inner-wall implemented into the house with a flexible floor plan. This concept is user-friendly as it is built on needs and the ownership's affordability. They can design the interior of the house however they want with using minimal cost because it does not involve wet construction.

  20. Characterization of bundled and individual triple-walled carbon nanotubes by resonant Raman spectroscopy.

    Science.gov (United States)

    Hirschmann, Thomas Ch; Araujo, Paulo T; Muramatsu, Hiroyuki; Zhang, Xu; Nielsch, Kornelius; Kim, Yoong Ahm; Dresselhaus, Mildred S

    2013-03-26

    The optical characterization of bundled and individual triple-walled carbon nanotubes was studied for the first time in detail by using resonant Raman spectroscopy. In our approach, the outer tube of a triple-walled carbon nanotube system protects the two inner tubes (or equivalently the inner double-walled carbon nanotube) from external environment interactions making them a partially isolated system. Following the spectral changes and line-widths of the radial breathing modes and G-band by performing laser energy dependent Raman spectroscopy, it is possible to extract important information as regards to the electronic and vibrational properties, tube diameters, wall-to-wall distances, radial breathing mode, and G-band resonance evolutions as well as high-curvature intertube interactions in isolated double- and triple-walled carbon nanotube systems.

  1. Passive House Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Strom, I.; Joosten, L.; Boonstra, C. [DHV Sustainability Consultants, Eindhoiven (Netherlands)

    2006-05-15

    PEP stands for 'Promotion of European Passive Houses' and is a consortium of European partners, supported by the European Commission, Directorate General for Energy and Transport. In this working paper an overview is given of Passive House solutions. An inventory has been made of Passive House solutions for new build residences applied in each country. Based on this, the most common basic solutions have been identified and described in further detail, including the extent to which solutions are applied in common and best practice and expected barriers for the implementation in each country. An inventory per country is included in the appendix. The analysis of Passive House solutions in partner countries shows high priority with regard to the performance of the thermal envelope, such as high insulation of walls, roofs, floors and windows/ doors, thermal bridge-free construction and air tightness. Due to the required air tightness, special attention must be paid to indoor air quality through proper ventilation. Finally, efficient ((semi-)solar) heating systems for combined space and DHW heating still require a significant amount of attention in most partner countries. Other basic Passive House solutions show a smaller discrepancy with common practice and fewer barriers have been encountered in partner countries. In the next section, the general barriers in partner countries have been inventoried. For each type of barrier a suggested approach has been given. Most frequently encountered barriers in partner countries are: limited know-how; limited contractor skills; and acceptation of Passive Houses in the market. Based on the suggested approaches to overcoming barriers, this means that a great deal of attention must be paid to providing practical information and solutions to building professionals, providing practical training to installers and contractors and communication about the Passive House concept to the market.

  2. The Insulation of Houses against Noise from Aircraft in Flight.

    Science.gov (United States)

    Scholes, W. E.; Parkin, P. H.

    Three groups of traditional houses were insulated against aircraft noise by double glazing and installing sound attenuating ventilator units. For upper floor rooms of two story houses, overall insulations of 35-40 dB were obtainable, providing transmission through the roofs and down flues were also reduced. The noise levels caused by ventilator…

  3. New Whole-House Solutions Case Study: Quadrant Homes

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-02-01

    Quadrant moved ducts and high efficiency furnace inside conditioned space on nearly all 300 customizable house plans. The builder uses dry, true factory-assembled walls, extensive air sealing, and just in time delivery for pre-sold homes.

  4. DOE Zero Energy Ready Home Case Study: Ithaca Neighborhood Housing Services, Ithaca, New York

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-10-01

    Eleven new townhomes comply with EPA's airPLUS criteria and use EPA WaterSense-qualifying features. Foundation walls are insulated on the exterior with XPS insulation. Non-shared walls use wall panels that were produced offsite. This builder was awarded a 2013 Housing Innovation Award in the affordable home category.

  5. Life Cycle Greenhouse Gas Emissions and Energy Analysis of Passive House with Variable Construction Materials

    Science.gov (United States)

    Baďurová, Silvia; Ponechal, Radoslav; Ďurica, Pavol

    2013-11-01

    The term "passive house" refers to rigorous and voluntary standards for energy efficiency in a building, reducing its ecological footprint. There are many ways how to build a passive house successfully. These designs as well as construction techniques vary from ordinary timber constructions using packs of straw or constructions of clay. This paper aims to quantify environmental quality of external walls in a passive house, which are made of a timber frame, lightweight concrete blocks and sand-lime bricks in order to determine whether this constructional form provides improved environmental performance. Furthermore, this paper assesses potential benefit of energy savings at heating of houses in which their external walls are made of these three material alternatives. A two storey residential passive house, with floorage of 170.6 m2, was evaluated. Some measurements of air and surface temperatures were done as a calibration etalon for a method of simulation.

  6. Energy renovation of an old single-family house

    DEFF Research Database (Denmark)

    Overgaard, L.L.; Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    After having identified a large potential for profitable energy renovation of the existing building stock, a demonstration project was carried out in practice. This paper deals with the methods and results from the demonstration project concerning a 161 m² poorly insulated single-family house built...... saving improvements carried out in the project are “easy to carry out” and cost-beneficial measures such as cavity wall insulation, loft insulation, insulation of walls under windows and a new second window-frame with energy-saving glass. The work was carried out by professional contractors at a total......). If a conservative way of financing the building work of 157,000 DKK is assumed, the first year’s cost equals DKK 8,500 and the house owner will gain a net saving the first year of DKK 7,500....

  7. Heat conduction in double-walled carbon nanotubes with intertube additional carbon atoms.

    Science.gov (United States)

    Cui, Liu; Feng, Yanhui; Tan, Peng; Zhang, Xinxin

    2015-07-07

    Heat conduction of double-walled carbon nanotubes (DWCNTs) with intertube additional carbon atoms was investigated for the first time using a molecular dynamics method. By analyzing the phonon vibrational density of states (VDOS), we revealed that the intertube additional atoms weak the heat conduction along the tube axis. Moreover, the phonon participation ratio (PR) demonstrates that the heat transfer in DWCNTs is dominated by low frequency modes. The added atoms cause the mode weight factor (MWF) of the outer tube to decrease and that of the inner tube to increase, which implies a lower thermal conductivity. The effects of temperature, tube length, and the number and distribution of added atoms were studied. Furthermore, an orthogonal array testing strategy was designed to identify the most important structural factor. It is indicated that the tendencies of thermal conductivity of DWCNTs with added atoms change with temperature and length are similar to bare ones. In addition, thermal conductivity decreases with the increasing number of added atoms, more evidently for atom addition concentrated at some cross-sections rather than uniform addition along the tube length. Simultaneously, the number of added atoms at each cross-section has a considerably more remarkable impact, compared to the tube length and the density of chosen cross-sections to add atoms.

  8. SEISMIC RESISTING PERFORMANCE OF A NEW DOUBLE TUBE HYBRID SYSTEM FOR MULTI-STORY BUILDINGS

    OpenAIRE

    Nasruddin

    2012-01-01

    Investigation on Double Tube Hybrid System (DTHS) through experimental work and analytical study are conducted as a part of the proposal on the seismic design method for Double Tubes Hybrid System (DTHS) for buildings. This structural system comprises Energy Dissipation Structural Walls (EDSW) as the interior tube and Spandrel Wall Frame (SWF) as the exterior tube. EDSW is composed of two reinforced concrete walls linked by steel coupling girders. The RC walls are not anchored to the foundati...

  9. 77 FR 14540 - Announcement of Funding Awards for the Public and Indian Housing Family Self-Sufficiency Program...

    Science.gov (United States)

    2012-03-12

    ... Authority of Bowling Green.... 247 Double Springs Road....... Bowling Green 42101 KY 42101 47,470 Housing... MI 49507 65,500 Saginaw Housing Commission 1803 Norman Street Saginaw 48605 MI 48605 48,675 Housing...

  10. Cost viability of 3D printed house in UK

    Science.gov (United States)

    Tobi, A. L. Mohd; Omar, S. A.; Yehia, Z.; Al-Ojaili, S.; Hashim, A.; Orhan, O.

    2018-03-01

    UK has been facing housing crisis due to the rising price of the property on sale. This paper will look into the viability of 3D printing technology as an alternative way for house construction on UK. The analysis will be carried out based on the data until the year of 2014 due to limited resources availability. Details cost breakdown on average size house construction cost in UK were analysed and relate to the cost viability of 3D printing technology in reducing the house price in UK. It is found that the 3D printing generates saving of up to around 35% out of total house price in UK. This cost saving comes from the 3D printed construction of walls and foundations for material and labour cost.

  11. Fail-safe first wall for preclusion of little leakage

    International Nuclear Information System (INIS)

    Shibui, Masanao; Nakahira, Masataka; Tada, Eisuke; Takatsu, Hideyuki

    1994-05-01

    Leakages although excluded by design measures would occur most probably in highly stressed areas, weldments and locations without possibility to classify the state by in-service inspection. In a water-cooled first wall, allowable leak rate of water is generally very small, and therefore, locating of the leak portion under highly activated environment will be very difficult and be time-consuming. The double-wall concept is promising for the ITER first wall, because it can be made fail-safe by the application of the leak-before-break and the multiple load path concepts, and because it has a potential capability to solve the little leak problem. When the fail safe strength is well defined, subcritical crack growth in the damaged wall can be permitted. This will enable to detect stable leakage of coolant without deteriorating plasma operation. The paper deals with the little leak problem and presents method for evaluating small leak rate of a liquid coolant from crack-like defects. The fail-safe first wall with the double-wall concept is also proposed for preclusion of little leakage and its fail-safety is discussed. (author)

  12. Detailed Dynamic Heat Transfer in Thick Brick Walls Typical of Lille Metropolis

    Directory of Open Access Journals (Sweden)

    Antczak E.

    2012-10-01

    Full Text Available The study of thermal transfer in old houses massive walls offers a big interest permitting the understanding of their specificities and the choice of a suitable material for their eventual insulation. We propose to study the thermal transfer in massive brick walls that characterize the Northern Europe old houses. To do so, we will begin by defining the thermal transfer mode: we proved that the transfer mode can be reduced to a unidirectional transfer. Then, an experimental wall is built and submitted to two different solicitation types (constant temperature in steady state mode and sinusoidal temperature through a wooden insulated box containing a radiator. The interest of these solicitations is to determine the thermal properties of the wall: the steady-state regime permits to determine the thermal resistances of the system when the harmonic regime permits to determine the thermal capacities of the system.

  13. Double mutation of cell wall proteins CspB and PBP1a increases secretion of the antibody Fab fragment from Corynebacterium glutamicum

    Science.gov (United States)

    2014-01-01

    Background Among other advantages, recombinant antibody-binding fragments (Fabs) hold great clinical and commercial potential, owing to their efficient tissue penetration compared to that of full-length IgGs. Although production of recombinant Fab using microbial expression systems has been reported, yields of active Fab have not been satisfactory. We recently developed the Corynebacterium glutamicum protein expression system (CORYNEX®) and demonstrated improved yield and purity for some applications, although the system has not been applied to Fab production. Results The Fab fragment of human anti-HER2 was successfully secreted by the CORYNEX® system using the conventional C. glutamicum strain YDK010, but the productivity was very low. To improve the secretion efficiency, we investigated the effects of deleting cell wall-related genes. Fab secretion was increased 5.2 times by deletion of pbp1a, encoding one of the penicillin-binding proteins (PBP1a), mediating cell wall peptidoglycan (PG) synthesis. However, this Δpbp1a mutation did not improve Fab secretion in the wild-type ATCC13869 strain. Because YDK010 carries a mutation in the cspB gene encoding a surface (S)-layer protein, we evaluated the effect of ΔcspB mutation on Fab secretion from ATCC13869. The Δpbp1a mutation showed a positive effect on Fab secretion only in combination with the ΔcspB mutation. The ΔcspBΔpbp1a double mutant showed much greater sensitivity to lysozyme than either single mutant or the wild-type strain, suggesting that these mutations reduced cell wall resistance to protein secretion. Conclusion There are at least two crucial permeability barriers to Fab secretion in the cell surface structure of C. glutamicum, the PG layer, and the S-layer. The ΔcspBΔpbp1a double mutant allows efficient Fab production using the CORYNEX® system. PMID:24731213

  14. APPLYING BIM TO BUILT HERITAGE WITH COMPLEX SHAPES: THE ICE HOUSE OF FILARETE’S OSPEDALE MAGGIORE IN MILAN, ITALY

    Directory of Open Access Journals (Sweden)

    D. Oreni

    2017-08-01

    Full Text Available This paper presents the development of a BIM model for a stratified historic structure characterized by a complex geometry: Filarete’s Ospedale Maggiore ice house, one of the few remaining historic ice houses in Milan (Fig. 1. Filarete, a well-known Renaissance architect and theorist, planned the hospital in the 15th century, but the ice house was built two centuries later with a double-storey irregular octagonal brick structure, half under and half above ground, that enclosed another circular structure called the ice room. The purpose of the double-walled structure was to store ice in the middle and store and preserve perishable food and medicine at the outer side of the ice room. During World War II, major portions of the hospital and the above-ground section of the ice house was bombed and heavily damaged. Later, in 1962, the hospital was restored and rehabilitated into a university, with the plan to conceal the ice house’s remaining structure in the courtyard, which ultimately was excavated and incorporated into a new library for the university. A team of engineers, architects, and students from Politecnico di Milano and Carleton University conducted two heritage recording surveys in 2015 and 2016 to fully document the existing condition of the ice house, resulting in an inclusive laser scanner and photogrammetric point cloud dataset. The point cloud data was consolidated and imported into two leading parametric modelling software, Autodesk Revit© and Graphisoft ArchiCAD©, with the goal to develop two BIMs in parallel in order to study and compare the software BIM workflow, parametric capabilities, attributes to capture the complex geometry with high accuracy, and the duration for parametric modelling. The comparison study of the two software revealed their workflow limitations, leading to integration of the BIM generative process with other pure modelling software such as Rhinoceros©. The integrative BIM process led to the production

  15. Strategy Guideline. Modeling Enclosure Design in Above-Grade Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, J. [Building Science Corporation, Westford, MA (United States); Ueno, K. [Building Science Corporation, Westford, MA (United States); Musunuru, S. [Building Science Corporation, Westford, MA (United States)

    2016-02-01

    The Strategy Guideline, written by the U.S. Department of Energy's research team Building Science Corporation, 1) describes how to model and interpret results of models for above-grade walls, and 2) analyzes the failure thresholds and criteria for above-grade walls. A library of above-grade walls with historically successful performance was used to calibrate WUFI (Wärme und Feuchte instationär) software models. The information is generalized for application to a broad population of houses within the limits of existing experience.

  16. On the vibrational behavior of single- and double-walled carbon nanotubes under the physical adsorption of biomolecules in the aqueous environment: a molecular dynamics study.

    Science.gov (United States)

    Ajori, S; Ansari, R; Darvizeh, M

    2016-03-01

    The adsorption of biomolecules on the walls of carbon nanotubes (CNTs) in an aqueous environment is of great importance in the field of nanobiotechnology. In this study, molecular dynamics (MD) simulations were performed to understand the mechanical vibrational behavior of single- and double-walled carbon nanotubes (SWCNTs and DWCNTs) under the physical adsorption of four important biomolecules (L-alanine, guanine, thymine, and uracil) in vacuum and an aqueous environment. It was observed that the natural frequencies of these CNTs in vacuum reduce under the physical adsorption of biomolecules. In the aqueous environment, the natural frequency of each pure CNT decreased as compared to its natural frequency in vacuum. It was also found that the frequency shift for functionalized CNTs as compared to pure CNTs in the aqueous environment was dependent on the radius and the number of walls of the CNT, and could be positive or negative.

  17. Effects of overlapping electric double layer on mass transport of a macro-solute across porous wall of a micro/nanochannel for power law fluid.

    Science.gov (United States)

    Bhattacharjee, Saikat; Mondal, Mrinmoy; De, Sirshendu

    2017-05-01

    Effects of overlapping electric double layer and high wall potential on transport of a macrosolute for flow of a power law fluid through a microchannel with porous walls are studied in this work. The electric potential distribution is obtained by coupling the Poisson's equation without considering the Debye-Huckel approximation. The numerical solution shows that the center line potential can be 16% of wall potential at pH 8.5, at wall potential -73 mV and scaled Debye length 0.5. Transport phenomena involving mass transport of a neutral macrosolute is formulated by species advective equation. An analytical solution of Sherwood number is obtained for power law fluid. Effects of fluid rheology are studied in detail. Average Sherwood number is more for a pseudoplastic fluid compared to dilatant upto the ratio of Poiseuille to electroosmotic velocity of 5. Beyond that, the Sherwood number is independent of fluid rheology. Effects of fluid rheology and solute size on permeation flux and concentration of neutral solute are also quantified. More solute permeation occurs as the fluid changes from pseudoplastic to dilatant. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Reduced Wall Acetylation Proteins Play Vital and Distinct Roles in Cell Wall O-Acetylation in Arabidopsis

    DEFF Research Database (Denmark)

    Manabe, Yuzuki; Verhertbruggen, Yves; Gille, Sascha

    2013-01-01

    The Reduced Wall Acetylation (RWA) proteins are involved in cell wall acetylation in plants. Previously, we described a single mutant, rwa2, which has about 20% lower level of O-acetylation in leaf cell walls and no obvious growth or developmental phenotype. In this study, we generated double....... The quadruple rwa mutant can be completely complemented with the RWA2 protein expressed under 35S promoter, indicating the functional redundancy of the RWA proteins. Nevertheless, the degree of acetylation of xylan, (gluco) mannan, and xyloglucan as well as overall cell wall acetylation is affected differently...... in different combinations of triple mutants, suggesting their diversity in substrate preference. The overall degree of wall acetylation in the rwa quadruple mutant was reduced by 63% compared with the wild type, and histochemical analysis of the rwa quadruple mutant stem indicates defects in cell...

  19. Comparison of DOE-2 with measurements in the Pala Test houses

    Energy Technology Data Exchange (ETDEWEB)

    Meldem, R.; Winkelmann, F.

    1995-07-01

    The predictions of the DOE-2 program for building energy analysis have been compared with measurements in the Pala test houses near San Diego. This work is part of the California Institute for Energy Efficiency {open_quotes}Alternatives to Compressor Cooling in California Transition Zones{close_quotes} project in which DOE-2 is being used for parametric analysis of cooling strategies that reduce peak electrical power in hot, dry climates. To establish the validity of DOE-2 for this kind of analysis the program was compared with room air temperature measurements in a {open_quotes}low-mass{close_quotes} house with conventional insulated study wall construction and a {open_quotes}high-mass{close_quotes} house with insulated concrete walls. To test different aspects of the DOE-2 calculation, four different unconditioned thermal configurations of these houses were considered: unshaded windows, shaded windows, white exterior surfaces, and forced night ventilation. In all cases DOE-2 agreed well with the air temperature measurements, with a mean deviation between simulation and measurement ranging from 0.2 to 1.0 K depending on configuration and type of house. Using a development version of DOE-2 comparisons with inside surface temperature measurements were also made. These comparisons also showed good agreement.

  20. Construction Costs Assessment of Structural Systems for Low-Rise and Social Welfare Housing

    Directory of Open Access Journals (Sweden)

    Carrillo Julián

    2015-09-01

    Full Text Available A comparative analysis of the costs related to the construction of low-rise, low-cost and social welfare housing was carried out. The study included three of the most commonly used structural systems for low-rise housing in Latin America, such as the traditional system of confined masonry walls, concrete walls conventionally reinforced with welded-wire meshes and concrete walls reinforced with steel fiber. The cost comparison was carried out by budgets analysis, which were performed based on construction quantities, unit prices and particular items for each structural system. It was found in the study that, from an economic point of view, the systems of concrete walls reinforced with welded-wire meshes or steel fibers are more advantageous than confined masonry systems. In addition, the integral comparison of the three structural systems demonstrates that the industrialized system of steel fiber reinforced concrete walls allows obtaining greater advantages of cleaning and sustainability, faster construction, lower cost and a more attractive scenario for builders investing in such projects.

  1. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    Science.gov (United States)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  2. Description of European Space Agency (ESA) Double Walled Isolator (DWI) Breadboard Currently Under Development for Demonstration of Critical Technology Foreseen to be Used in the Mars Sample Receiving Facility (MSRF)

    Science.gov (United States)

    Vrublevskis, J.; Berthoud, L.; McCulloch, Y.; Bowman, P.; Holt, J.; Bridges, J.; Bennett, A.; Gaubert, F.; Duvet, L.

    2018-04-01

    The need for biocontainment from Planetary Protection Policy and the need for cleanliness for scientific investigation requires that the samples returned from Mars by the Mars Sample Return (MSR) mission must be handled in a Double Walled Isolator (DWI).

  3. 7 CFR 3560.70 - Supplemental requirements for manufactured housing.

    Science.gov (United States)

    2010-01-01

    ... by the jurisdiction where the housing is located if such taxation is permitted under applicable law... the manufactured homes sustained no hidden damage during transportation and, for double-wide units...

  4. Affordable house designs to improve health in rural Africa: a field study from northeastern Tanzania.

    Science.gov (United States)

    von Seidlein, Lorenz; Ikonomidis, Konstantin; Mshamu, Salum; Nkya, Theresia E; Mukaka, Mavuto; Pell, Christopher; Lindsay, Steven W; Deen, Jacqueline L; Kisinza, William N; Knudsen, Jakob B

    2017-08-01

    The population of sub-Saharan Africa is currently estimated to be 1245 million and is expected to quadruple by the end of the century, necessitating the building of millions of homes. Malaria remains a substantial problem in this region and efforts to minimise transmission should be considered in future house planning. We studied how building elements, which have been successfully employed in southeast Asia to prevent mosquitos from entering and cooling the house, could be integrated in a more sustainable house design in rural northeastern Tanzania, Africa, to decrease mosquito density and regulate indoor climate. In this field study, six prototype houses of southeast Asian design were built in in the village of Magoda in Muheza District, Tanga Region, Tanzania, and compared with modified and unmodified, traditional, sub-Saharan African houses. Prototype houses were built with walls made of lightweight permeable materials (bamboo, shade net, or timber) with bedrooms elevated from the ground and with screened windows. Modified and unmodified traditional African houses, wattle-daub or mud-block constructions, built on the ground with poor ventilation served as controls. In the modified houses, major structural problems such as leaking roofs were repaired, windows screened, open eaves blocked with bricks and mortar, cement floors repaired or constructed, and rain gutters and a tank for water storage added. Prototype houses were randomly allocated to village households through a free, fair, and transparent lottery. The lottery tickets were deposited in a bucket made of transparent plastic. Each participant could draw one ticket. Hourly measurements of indoor temperature and humidity were recorded in all study houses with data loggers and mosquitoes were collected indoors and outdoors using Furvela tent traps and were identified with standard taxonomic keys. Mosquitoes of the Anopheles gambiae complex were identified to species using PCR. Attitudes towards the new house

  5. Retrofitted green roofs and walls and improvements in thermal comfort

    Science.gov (United States)

    Feitosa, Renato Castiglia; Wilkinson, Sara

    2017-06-01

    Increased urbanization has led to a worsening in the quality of life for many people living in large cities in respect of the urban heat island effect and increases of indoor temperatures in housing and other buildings. A solution may be to retrofit existing environments to their former conditions, with a combination of green infrastructures applied to existing walls and rooftops. Retrofitted green roofs may attenuate housing temperature. However, with tall buildings, facade areas are much larger compared to rooftop areas, the role of green walls in mitigating extreme temperatures is more pronounced. Thus, the combination of green roofs and green walls is expected to promote a better thermal performance in the building envelope. For this purpose, a modular vegetated system is adopted for covering both walls and rooftops. Rather than temperature itself, the heat index, which comprises the combined effect of temperature and relative humidity is used in the evaluation of thermal comfort in small scale experiments performed in Sydney - Australia, where identical timber framed structures prototypes (vegetated and non-vegetated) are compared. The results have shown a different understanding of thermal comfort improvement regarding heat index rather than temperature itself. The combination of green roof and walls has a valid role to play in heat index attenuation.

  6. NCSU solar energy and conservation house. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-10-01

    A passive solar energy house has been built adjacent to the NCSU McKimmon Continuing Education Center. The house contains a two-story embedded sunspace, two Trombe walls, active solar hot water heating, thermal storage in a rock filled ceiling/floor, and numerous research treatments, and energy conservation features. (See attached photo brochure; Appendix 1). The house is completely decorated and furnished in an attractive manner and the exterior architecture is traditional and has broad consumer appeal. It is also thoroughly instrumented to monitor performance. The house is open to the public on weekends and numerous people come to visit on their own initiative and others take advantage of the close proximity to McKimmon while there attending conferences. The house will influence and motivate large numbers of people to consider solar and energy conservation facets in their homes and will provide data to substantiate performance to prospective home buyers and meaningful data on design and construction for builders.

  7. Akit’s house: identification of vernacular coastal architecture in Meranti Island

    Science.gov (United States)

    Faisal, G.; Amanati, R.

    2018-03-01

    Akit people can be found on Meranti islands near east coast Sumatra. Their houses made mainly by wood construction as stilt type house. The roof of the house was made by leaves, and bark of the tree was used on house wall. Nowadays, some changes have occurred on this vernacular house. The changes are not only as responding to the environment, environment but also are affecting by way of their life. In turn, this changing becomes an interesting phenomenon, particular comparing to the house on other islands. This research has conducted in qualitative research approach to identify how the changes of the house. Field data gathered by a range of methods such as observation, story-telling, and documentation. The data are analyzed and interpreted within an iterative process to expand understanding of the house’s changing. This research offers an architectural insight into how the vernacular houses are changing.

  8. Building a 40% Energy Saving House in the Mixed-Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Christian, Jeffrey E [ORNL; Bonar, Jacob [ORNL

    2011-10-01

    This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar

  9. Comprehensive energy and economic analyses on a zero energy house versus a conventional house

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, L. [School of Architecture, Tianjin University, Tianjin, 300072 (China); Hurt, R.; Correa, D.; Boehm, R. [Center for Energy Research, University of Nevada, Las Vegas, NV 89154 (United States)

    2009-09-15

    A zero energy house (ZEH) was built side by side with a baseline house in suburban Las Vegas. Actual energy performance measurements were carried out on the incorporated energy saving features and solar applications. The data show that a radiant barrier and a water-cooled air conditioner are major contributors to the energy savings, while an insulated floor slab and thermal mass walls are not effective for energy-conservation during cooling periods. Photovoltaic roof tiles produce enough green power to cover the use in the ZEH, and the solar water heater can reach a peak efficiency of 80%. The energy saving contribution of each incorporated component was obtained using Energy10 and eQUEST3.6 models, and then these codes were used for economic application evaluation. The two analysis codes yield similar results that compare well with the actual building performance data. Four items are clearly economically valuable for these applications: high performance windows, compact fluorescent lights, highly-insulated roofs and air conditioners with water-cooled condensers. PV tiles show a good financial return when rebates are considered. The Integrated Collector Storage (ICS) unit has a high efficiency but with a little higher thermal price. Thermal mass walls are too costly to have wide market appeal. (author)

  10. [Claw size of Scottish Highland Cows after pasture and housing periods].

    Science.gov (United States)

    Nuss, K; Kolp, E; Braun, U; Weidmann, E; Hässig, M

    2014-09-01

    The claws of pastured Scottish Highland Cattle are large and this may raise the question if regular claw trimming is necessary. Therefore, the claws of the right thoracic and pelvic limbs were measured in 22 Scottish Highland cows 4 times 8 weeks apart. The cows were kept on various alpine pastures before the first measurement, on a two-hectare low-land pasture before the second measurement, in a welfare-compliant straw-bedded free stall before the third measurement and on alpine pasture before the fourth measurement. Housing conditions significantly affected claw dimensions. The claws were composed of dry, hard horn during pasture periods, and had prominent weight-bearing hoof-wall borders and soles with a natural axial slope. Long dorsal walls and heels and a greater symmetry were common. Claw lesions were absent. In contrast, free-stall housing was associated with shorter toes and steeper toe angles, but white line deterioration, heel horn erosion, wearing of the axial slope and hoof wall edges were common.

  11. The surface chemical properties of multi-walled carbon nanotubes modified by thermal fluorination for electric double-layer capacitor

    Science.gov (United States)

    Jung, Min-Jung; Jeong, Euigyung; Lee, Young-Seak

    2015-08-01

    The surfaces of multi-walled carbon nanotubes (MWCNTs) were thermally fluorinated at various temperatures to enhance the electrochemical properties of the MWCNTs for use as electric double-layer capacitor (EDLC) electrodes. The fluorine functional groups were added to the surfaces of the MWCNTs via thermal fluorination. The thermal fluorination exposed the Fe catalyst on MWCNTs, and the specific surface area increased due to etching during the fluorination. The specific capacitances of the thermally fluorinated at 100 °C, MWCNT based electrode increased from 57 to 94 F/g at current densities of 0.2 A/g, respectively. This enhancement in capacitance can be attributed to increased polarization of the thermally fluorinated MWCNT surface, which increased the affinity between the electrode surface and the electrolyte ions.

  12. Econometric modelling of risk adverse behaviours of entrepreneurs in the provision of house fittings in China

    Directory of Open Access Journals (Sweden)

    Rita Yi Man Li

    2012-03-01

    Full Text Available Entrepreneurs have always born the risk of running their business. They reap a profit in return for their risk taking and work. Housing developers are no different. In many countries, such as Australia, the United Kingdom and the United States, they interpret the tastes of the buyers and provide the dwellings they develop with basic fittings such as floor and wall coverings, bathroom fittings and kitchen cupboards. In mainland China, however, in most of the developments, units or houses are sold without floor or wall coverings, kitchen  or bathroom fittings. What is the motive behind this choice? This paper analyses the factors affecting housing developers’ decisions to provide fittings based on 1701 housing developments in Hangzhou, Chongqing and Hangzhou using a Probit model. The results show that developers build a higher proportion of bare units in mainland China when: 1 there is shortage of housing; 2 land costs are high so that the comparative costs of providing fittings become relatively low.

  13. An optimization algorithm for simulation-based planning of low-income housing projects

    Directory of Open Access Journals (Sweden)

    Mohamed M. Marzouk

    2010-10-01

    Full Text Available Construction of low-income housing projects is a replicated process and is associated with uncertainties that arise from the unavailability of resources. Government agencies and/or contractors have to select a construction system that meets low-income housing projects constraints including project conditions, technical, financial and time constraints. This research presents a framework, using computer simulation, which aids government authorities and contractors in the planning of low-income housing projects. The proposed framework estimates the time and cost required for the construction of low-income housing using pre-cast hollow core with hollow blocks bearing walls. Five main components constitute the proposed framework: a network builder module, a construction alternative selection module, a simulation module, an optimization module and a reporting module. An optimization module utilizing a genetic algorithm enables the defining of different options and ranges of parameters associated with low-income housing projects that influence the duration and total cost of the pre-cast hollow core with hollow blocks bearing walls method. A computer prototype, named LIHouse_Sim, was developed in MS Visual Basic 6.0 as proof of concept for the proposed framework. A numerical example is presented to demonstrate the use of the developed framework and to illustrate its essential features.

  14. Radon emanation rate in construction materials and various design of house

    International Nuclear Information System (INIS)

    Ahmad Asyraf Osman

    2012-01-01

    Indoor air quality are important factors that need to be addressed because it can affect the health and comfort of occupants in it. Among the major sources of indoor air pollution are radon gas. Radiological risk due to radon gas due to its intake into the human body is the major cause of lung cancer. This study was conducted to determine the radon emanation rate that occurs naturally in the building materials and its contains in several kinds of house. Construction materials studied are sand, gravel, cement and bricks. Terrace houses, double storey terrace houses, flats and wooden houses were studied in radon emanation in various types of houses. Radon emanation rates in building materials in a variety of home and the home measured using Sun Nuclear radon monitor (model 1029) and radon gas concentrations are measured in units of Bq m -3 . From the results, granites have recorded the highest radon emissions that is 2.67 μBq kg -1 s -1 , followed by sand with 2.53 μBq kg -1 s -1 . The bricks emission rate were recorded was 2.47 μBq kg -1 s -1 , while Cement recorded the lowest with only 1.46 μBq kg -1 s -1 . In study of radon in a variety of home, the results showed that the single storey terrace houses recorded the highest reading of 25.67 ± 4.96 Bq m -3 . First level Double storey terrace houses recorded 23.24 ± 3.72 Bq m -3 compared with a second level of two-storey terrace house which recorded emission rate of 16.43 ± 2.53 Bq m -3 . Flats were recorded the second lowest with only 13.07 ± 2.38 Bq m -3 . House that recorded the lowest reading was wooden houses that recorded 9.53 ± 1.96 Bq m -3 . (author)

  15. Density functional theory of the electrical double layer: the RFD functional

    International Nuclear Information System (INIS)

    Gillespie, Dirk; Valisko, Monika; Boda, Dezso

    2005-01-01

    Density functional theory (DFT) of electrolytes is applied to the electrical double layer under a wide range of conditions. The ions are charged, hard spheres of different size and valence, and the wall creating the double layer is uncharged, weakly charged, and strongly charged. Under all conditions, the density and electrostatic potential profiles calculated using the recently proposed RFD electrostatic functional (Gillespie et al 2002 J. Phys.: Condens. Matter 14 12129; 2003 Phys. Rev. E 68 031503) compare well to Monte Carlo simulations. When the wall is strongly charged, the RFD functional results agree with the results of a simpler perturbative electrostatic DFT, but the two functionals' results qualitatively disagree when the wall is uncharged or weakly charged. The RFD functional reproduces these phenomena of weakly charged double layers. It also reproduces bulk thermodynamic quantities calculated from pair correlation functions

  16. 76 FR 55407 - Announcement of Funding Awards; Public and Indian Housing Family Self-Sufficiency Program Under...

    Science.gov (United States)

    2011-09-07

    ... Bowling Green 247 Double Springs Bowling Green........ KY 42101 47,740 Road. Housing Authority of Glasgow... Norman Street... Saginaw MI 48605 48,675 Housing and Redevelopment 442 Pine Mill Court.. Virginia MN...

  17. Validation of an automatic system (DoubleCage) for detecting the location of animals during preference tests.

    Science.gov (United States)

    Tsai, P P; Nagelschmidt, N; Kirchner, J; Stelzer, H D; Hackbarth, H

    2012-01-01

    Preference tests have often been performed for collecting information about animals' acceptance of environmental refinement objects. In numerous published studies animals were individually tested during preference experiments, as it is difficult to observe group-housed animals with an automatic system. Thus, videotaping is still the most favoured method for observing preferences of socially-housed animals. To reduce the observation workload and to be able to carry out preference testing of socially-housed animals, an automatic recording system (DoubleCage) was developed for determining the location of group-housed animals in a preference test set-up. This system is able to distinguish the transition of individual animals between two cages and to record up to 16 animals at the same time (four animals per cage). The present study evaluated the reliability of the DoubleCage system. The data recorded by the DoubleCage program and the data obtained by human observation were compared. The measurements of the DoubleCage system and manual observation of the videotapes are comparable and significantly correlated (P animals and a considerable reduction of animal observation time.

  18. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for new detached houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    R and D was made on solar systems for new detached houses, and design and construction of the experimental house were carried out. In system analysis, assessment of solar cooling/heating systems, improvement of a simulation model based on measured data, and improvement of cooling/heating systems by simulation were conducted. In development of equipment and materials for the experimental house, R and D was made on component materials, connection method and installation method on houses for vacuum glass tube type solar collectors, and a solar collector was fabricated. R and D was also made on combination of absorbent and coolant, drop type coolant generator and performance experiment for absorption refrigerators, and a refrigerator was fabricated. The experimental house is 2-stored RC wall construction of 79.94m{sup 2} in building area, and 133.26m{sup 2} in total floor area. From the viewpoint of energy saving, outside insulation, double window, and insulating rain shutter door were adopted. The newly developed vacuum glass tube type solar collector is applicable to existing houses because of its higher flexibility. (NEDO)

  19. Effects of reducing temperatures on the hydrogen storage capacity of double-walled carbon nanotubes with Pd loading.

    Science.gov (United States)

    Sheng, Qu; Wu, Huimin; Wexler, David; Liu, Huakun

    2014-06-01

    The effects of different temperatures on the hydrogen sorption characteristics of double-walled carbon nanotubes (DWCNTs) with palladium loading have been investigated. When we use different temperatures, the particle sizes and specific surface areas of the samples are different, which affects the hydrogen storage capacity of the DWCNTs. In this work, the amount of hydrogen storage capacity was determined (by AMC Gas Reactor Controller) to be 1.70, 1.85, 2.00, and 1.93 wt% for pristine DWCNTS and for 2%Pd/DWCNTs-300 degrees C, 2%Pd/DWCNTs-400 degrees C, and 2%Pd/DWCNTs-500 degrees C, respectively. We found that the hydrogen storage capacity can be enhanced by loading with 2% Pd nanoparticles and selecting a suitable temperature. Furthermore, the sorption can be attributed to the chemical reaction between atomic hydrogen and the dangling bonds of the DWCNTs.

  20. Effect of interwall interaction on the electronic structure of double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Soto, M; Boyer, T A; Biradar, S; Ge, L; Vajtai, R; Ajayan, P M; Barrera, E V; Elías-Zúñiga, A

    2015-01-01

    Through this study, the results of density functional theory calculations within the local density approximation of the electronic structure of zigzag–zigzag double-walled carbon nanotubes (DWCNTs), with chiral indices (n, 0)@(m, 0) for n = 7–15, and m = 15–26, has been presented and the effects of interwall interaction and orbital hybridization on the electronic structure of these systems has been discussed. It was observed that the electronic band gap of the aforementioned DWCNTs depends on the interwall distance only for metallic–semiconductor configurations and on the intrinsic properties of the constituent tubes in all other combinations. It was also observed that the calculated band gap for most of the metallic–metallic DWCNTs was smaller than semiconductor–metallic, metallic–semiconductor, and semiconductor–semiconductor configurations. Metallic–semiconductor DWCNTs were found to be desirable for band gap tuning applications because of their dependence on interwall distance, opening up the possibility of using such systems in electronic device applications, such as transistors. Other applications include the use of DWCNTs in macroscopic carbon nanotube conducting wires, for which metallic–metallic and semiconducting–metallic zigzag–zigzag DWCNTs were found to be the most desirable configurations due to their small band gaps. (paper)

  1. Overview of impurity control and wall conditioning in NSTX

    International Nuclear Information System (INIS)

    Kugel, H.W.; Maingi, R.; Wampler, W.; Barry, R.E.; Bell, M.; Blanchard, W.; Gates, D.; Johnson, D.; Kaita, R.; Kaye, S.; Maqueda, R.; Menard, J.; Menon, M.M.; Mueller, D.; Ono, M.; Paul, S.; Peng, Y-K.M.; Raman, R.; Roquemore, A.; Skinner, C. H.; Sabbagh, S.; Stratton, B.; Stutman, D.; Wilson, J. R.; Zweben, S.

    2000-01-01

    The National Spherical Torus Experiment (NSTX) started plasma operations i n February 1999. In the first extended period of experiments, NSTX achieved high current, inner wall limited, double null, and single null plasma discharges, initial Coaxial Helicity Injection, and High Harmonic Fast Wave results. As expected, discharge reproducibility and performance were strongly affected by wall conditions. In this paper, the authors describe the internal geometry, and initial plasma discharge, impurity control, wall conditioning, erosion, and deposition results

  2. Stable cycling of double-walled silicon nanotube battery anodes through solid–electrolyte interphase control

    KAUST Repository

    Wu, Hui

    2012-03-25

    Although the performance of lithium ion-batteries continues to improve, their energy density and cycle life remain insufficient for applications in consumer electronics, transport and large-scale renewable energy storage 1-5. Silicon has a large charge storage capacity and this makes it an attractive anode material, but pulverization during cycling and an unstable solid-electrolyte interphase has limited the cycle life of silicon anodes to hundreds of cycles 6-11. Here, we show that anodes consisting of an active silicon nanotube surrounded by an ion-permeable silicon oxide shell can cycle over 6,000 times in half cells while retaining more than 85% of their initial capacity. The outer surface of the silicon nanotube is prevented from expansion by the oxide shell, and the expanding inner surface is not exposed to the electrolyte, resulting in a stable solid-electrolyte interphase. Batteries containing these double-walled silicon nanotube anodes exhibit charge capacities approximately eight times larger than conventional carbon anodes and charging rates of up to 20C (a rate of 1C corresponds to complete charge or discharge in one hour). © 2012 Macmillan Publishers Limited. All rights reserved.

  3. Vulnerability of housing buildings in Bucharest, Romania

    Science.gov (United States)

    Bostenaru, M.

    2009-04-01

    The author participates to the World Housing Encyclopedia project (www.world-housing.net), an internet based database of housing buildings in earthquake prone areas of the world. This is a voluntary project run by the Earthquake Engineering Research Institute, Oakland, California and the International Association of Earthquake Engineering, financial means being available only for the website where the information is shared. For broader dissemination in 2004 a summary publication of the reports to date was published. The database can be querried for various parameters and browsed after geographic distribution. Participation is open to any housing experts. Between 2003 and 2006 the author was also member of the editorial board. The author contributed numerous reports about building types in Romania, and each one about building types in Germany and Switzerland. This presentation will be about the contributed reports on building types in Romania. To the Encyclopedia eight reports on building types from Bucharest were contributed, while in further research of the author one more was similarly described regarding the vulnerability and the seismic retrofit. The selection of these types was done considering the historic development of the built substance in Bucharest from 1850 on, time from which a representative amount of housing buildings which can be classified in typologies can be found in Bucharest. While the structural types are not necessarily characteristic for the style, since the style has other time limits, often appearing before the type became common and then remaining being practiced also after another style gained ground, a historic succession can be seen also in this case. The nine types considered can be grouped in seven time categories: - the time 1850-1880, for a vernacular housing type with masonry load bearing walls and timber floors, - the time 1880-1920, for the type of two storey or multi-storey house with masonry walls and timber floors (in which

  4. Access to housing subsidies, housing status, drug use and HIV risk among low-income U.S. urban residents

    Directory of Open Access Journals (Sweden)

    Dickson-Gomez Julia

    2011-11-01

    street or in a shelter, or temporarily doubling up with friends, acquaintances or sex partners. Living with friends, acquaintances or sex partners was associated with greater sexual risk than those living on the street or in other stable housing situations. Conclusions Results suggest that providing low-income and supportive housing may be an effective structural HIV prevention intervention, but that the availability and accessibility of these programs must be increased.

  5. From (c)old house to an energy-saving house. Information on the energy conservation in the old building; Vom (K)althaus zum Energiesparhaus. Wissenswertes ueber die Energieeinsparung im Altbau

    Energy Technology Data Exchange (ETDEWEB)

    Eicke-Hennig, Werner; Fey, Klaus

    2013-04-01

    The contribution under consideration reports on energy savings opportunities for one- and two-family houses which account for a large part of the building stock. The halving of the consumption of heating energy is a clear message. With the following six steps, an energy efficient house can be attained from each house: insulation of the roof, insulation of exterior walls, new windows with heat-insulating glass, insulating of the basement ceiling, modernization of the heating system as by condensing boilers, power-saving circulating pump, solar water heating system.

  6. COMPARISON OF SENSORS FOR RESISTIVE WALL MODE FEEDBACK CONTROL. MILESTONE No.145 ''CONTAINING PLASMA INSTABILITIES WITH METAL WALLS''

    International Nuclear Information System (INIS)

    STRAIT, E.J.; CHU, M.S.; GAROFALO, A.M.; LAHAYE, R.J.; OKABAYASHI, M.; REIMERDES, H.; SCOVILLE, J.T.; TURNBULL, A.D.

    2002-01-01

    OAK A271 COMPARISON OF SENSORS FOR RESISTIVE WALL MODE FEEDBACK CONTROL MILESTONE No.145 CONTAINING PLASMA INSTABILITIES WITH METAL WALLS. The most serious instabilities in the tokamak are those described by ideal magneto-hydrodynamic theory. These modes limit the stable operating space of the tokamak. The ideal MHD calculations predict the stable operating space of the tokamak may be approximately doubled when a perfectly conducting metal wall is placed near the plasma boundary, compared to the case with no wall (free boundary). The unstable mode distortions of the plasma column cannot bulge out through a perfectly conducting wall. However, real walls have finite conductivity and when plasmas are operated in the regime between the free boundary stability limit and the perfectly conducting wall limit, the unstable mode encountered in that case the resistive wall mode, can leak out through the metal wall, allowing the mode to keep slowly growing. The slow growth affords the possibility of feedback stabilizing this mode with external coils. DIII-D is making good progress in such feedback stabilization research and in 2002 will use an improved set of mode sensors inside the vacuum vessel and closer to the plasma surface which are expected theoretically to improve the ability to stabilize the resistive wall mode

  7. Flow instability research on steam generator with straight double-walled heat transfer tube for FBR. Pressure drop under high pressure condition

    International Nuclear Information System (INIS)

    Liu, Wei; Tamai, Hidesada; Yoshida, Hiroyuki; Takase, Kazuyuki; Hayafune, Hiroki; Futagami, Satoshi; Kisohara, Naoyuki

    2008-01-01

    For the Steam Generator (SG) with straight double-walled heat transfer tube that used in sodium cooled Faster Breeder Reactor, flow instability is one of the most important items need researching. As the first step of the research, thermal hydraulics experiments were performed under high pressure condition in JAEA with using a straight tube. Pressure drop, heat transfer coefficients and void fraction data were derived. This paper evaluates the pressure drop data with TRAC-BF1 code. The Pffan's correlation for single phase flow and the Martinelli-Nelson's two-phase flow multiplier are found can be well predicted the present pressure drop data under high pressure condition. (author)

  8. A study of UGI series for improvement of diagnosis on the anterior wall of the stomach

    International Nuclear Information System (INIS)

    Lee, Won Hong; Son, Soon Yong; Kang, Hyoung Wook

    1997-01-01

    This paper is to investigate a more detailed method for the diagnosis of anterior wall of the stomach by making a comparative study with several hospitals. It has been true that there have been hospitals, that have not examined anterior wall of the stomach. However, it is very important for us to examine anterior wall of the stomach for an early detection of gastric carcinoma. The results of the study are as follows : 1. Frequency of occurrence of the early gastric carcinoma for the anterior wall were 50 cases and 34 cases for the posterior wall out of 84 cases. 2. Only a hospitals have examined the anterior wall of stomach. 3. In case of operation, only a hospitals have used two techniques at for same time single and double contrast studies. 4. Only one hospital used a compression pad and three hospitals had only filing state images taken. 5. In general, l chest of film was used and the number of exposures rouged from 1 to 2 times. Lesions on the anterior wall of the stomach can be shown by the combination of prone single compression and supine double contrast radiographs. Therefore, the conclusion came to the result that the prone single compression and supine double contract technique of the anterior wall are indispensable methods to the routine check of the stomach

  9. Experimental facility design for a gap heat transfer in a double wall tube

    International Nuclear Information System (INIS)

    Nam, Ho Yun; Hong, Jong Gan; Kim, Jong Man; Kim, Jong Bum; Jeong, Ji Young

    2012-01-01

    A reliable steam generator design is one of the most critical issues in developing a sodium cooled fast reactor (SFR), and various efforts to avoid potential sodium water reaction (SWR) have been made. For this reason, SFR steam generators have been developed to improve its reliability using a double wall tube (DWT), which has two barriers between the sodium and water. Most steam generators for SFRs are the shell and tube type. Steam at high pressure and low temperature flows inside the inner tubes, which are heated by the shell side sodium at low pressure and high temperature. Since the inner and outer tubes of conventional DWTs are made of identical materials, the degree of thermal expansion is somewhat different between the two concentric tubes owing to their temperature difference. Therefore, a greater temperature difference results in less contact pressures between the inner and outer tubes. This feature results in a deterioration of the heat transfer capability of DWTs. Current developments are focused on an improvement of heat transfer capability by investigating the gap conductance between the two concentric tubes. To improve the heat transfer capability of DWTs, it is preferable to use different tube materials (Fig. 1). It is recommended to choose the inner tube material whose thermal expansion coefficient is greater than that of the outer tube by 10 to 15%

  10. Quantifying the importance of galactofuranose in Aspergillus nidulans hyphal wall surface organization by atomic force microscopy.

    Science.gov (United States)

    Paul, Biplab C; El-Ganiny, Amira M; Abbas, Mariam; Kaminskyj, Susan G W; Dahms, Tanya E S

    2011-05-01

    The fungal wall mediates cell-environment interactions. Galactofuranose (Galf), the five-member ring form of galactose, has a relatively low abundance in Aspergillus walls yet is important for fungal growth and fitness. Aspergillus nidulans strains deleted for Galf biosynthesis enzymes UgeA (UDP-glucose-4-epimerase) and UgmA (UDP-galactopyranose mutase) lacked immunolocalizable Galf, had growth and sporulation defects, and had abnormal wall architecture. We used atomic force microscopy and force spectroscopy to image and quantify cell wall viscoelasticity and surface adhesion of ugeAΔ and ugmAΔ strains. We compared the results for ugeAΔ and ugmAΔ strains with the results for a wild-type strain (AAE1) and the ugeB deletion strain, which has wild-type growth and sporulation. Our results suggest that UgeA and UgmA are important for cell wall surface subunit organization and wall viscoelasticity. The ugeAΔ and ugmAΔ strains had significantly larger surface subunits and lower cell wall viscoelastic moduli than those of AAE1 or ugeBΔ hyphae. Double deletion strains (ugeAΔ ugeBΔ and ugeAΔ ugmAΔ) had more-disorganized surface subunits than single deletion strains. Changes in wall surface structure correlated with changes in its viscoelastic modulus for both fixed and living hyphae. Wild-type walls had the largest viscoelastic modulus, while the walls of the double deletion strains had the smallest. The ugmAΔ strain and particularly the ugeAΔ ugmAΔ double deletion strain were more adhesive to hydrophilic surfaces than the wild type, consistent with changes in wall viscoelasticity and surface organization. We propose that Galf is necessary for full maturation of A. nidulans walls during hyphal extension.

  11. Field-incidence noise transmission loss of general aviation aircraft double wall configurations

    Science.gov (United States)

    Grosveld, F. W.

    1984-01-01

    Theoretical formulations have been developed to describe the transmission of reverberant sound through an infinite, semi-infinite and a finite double panel structure. The model incorporates the fundamental resonance frequencies of each of the panels, the mass-air-mass resonances of the structure, the standing wave resonances in the cavity between the panels and finally the coincidence resonance regions, where the exciting sound pressure wave and flexural waves of each of the panels coincide. It is shown that phase cancellation effects of pressure waves reflected from the cavity boundaries back into the cavity allows the transmission loss of a finite double panel structure to be approximated by a finite double panel mounted in an infinite baffle having no cavity boundaries. Comparison of the theory with high quality transmission loss data yields good agreement in the mass-controlled frequency region. It is shown that the application of acoustic blankets to the double panel structure does not eliminate the mass-air-mass resonances if those occur at low frequencies. It is concluded that this frequency region of low noise transmission loss is a potential interior noise problem area for propeller driven aircraft having a double panel fuselage construction.

  12. HOUSING CONDITIONS IN KANO, NIGERIA: A QUALITATIVE ASSESSMENT OF ADEQUACY

    Directory of Open Access Journals (Sweden)

    Abdulqadir BELLO

    2017-09-01

    Full Text Available Many studies have attempted to assess the qualitative adequacy of housing in Nigeria. However, most of these studies focus either on slums or on public housing projects. There are very few empirical studies that examine and compare the qualitative adequacy of housing belonging to different population groups and from different neighborhoods in a city. The purpose of this study is to assess the housing quality in the (entire city of Kano, Nigeria and to examine the disparities in housing adequacy across the city based on four factors: neighborhood density level, location of the neighborhood relative to the old city wall, monthly household income and ownership type and status. We found that, although bad by western standards, the condition of dwellings in Kano is better than in other Nigerian cities (based on information from previous studies, even when we consider only the high-density neighborhoods. Another major conclusion of this paper is that the four indicators mentioned earlier can be used as predictors for the quality of housing in a particular neighborhood.

  13. Urban housing experiments in Yugoslavia 1948-1970

    Directory of Open Access Journals (Sweden)

    Alfirević Đorđe

    2015-01-01

    Full Text Available In the period from 1948 to 1970 urban housing architecture in Yugoslavia had a distinctly experimental character as it strived intensively towards research and establishment of new architectural patterns and values that would mark the period of economic growth of the country. In conditions of mass housing construction, initiated by the devastated urban housing fund after the Second World War, significant influx of population to towns and the state directed its socialist aspirations at alloting every family acceptable living space. The period of the so-called “directed housing construction“, whose imperative was to establish the limits of existential minimum in collective housing, maximal space “packing“ and optimal functionality of flats, at the same time represents the most significant period in the development of housing architecture in Yugoslavia. The architects focused their interests in housing in mainly three directions: a the creation and application of new prefabrication systems, b innovative application of modernistic patterns in aestheticization of architecture and c experimenting with space units which will enable a higher level of privacy in high-density housing conditions. The first direction of research emerged in the context of post-war housing construction of a wide scope, which encouraged the advance of technological research in areas of prefabrication and practical application of achieved results on the whole territory of Yugoslavia. The second direction dealt with architectural planning which was strictly subordinated to social and ideological sphere with domineering socialist monumentalism and artistic and sculptural approach to architecture. The third was related to experimental tendency with new urban housing patterns which aimed to search and find more pragmatic, humane solutions within mass high-density housing constructions which were the first to utilize and show examples of “double-tract” buildings. These

  14. Influence of Housing Wall Compliance on Shock Absorbers in the Context of Vehicle Dynamics

    Science.gov (United States)

    Pulvirenti, G.; Faria, C.

    2017-10-01

    Shock absorbers play a key role in vehicle dynamics. Researchers have spent significant effort in order to understand phenomena associated with this component, but there are still several issues to address, in part because new technology development and design trends continually lead to new challenges, among which weight reduction is crucial. For shock absorbers, weight reduction is related to the use of new materials (e.g. composite) or new design paradigms (e.g. more complex geometry, wall thickness, etc.). All of them are directly linked to wall compliance values higher than the actual ones. The present article proposes a first analysis of the phenomena introduced by a high wall compliance, through a modelling approach and various simulations in order to understand the vehicle behaviour changes. It is shown that high values of wall compliance lead to increased hysteresis in the force-velocity curve. However, comfort, handling and ride performances are not significantly affected by this designing parameter.

  15. Highly transparent and conductive thin films fabricated with nano-silver/double-walled carbon nanotube composites.

    Science.gov (United States)

    Lee, Shie-Heng; Teng, Chih-Chun; Ma, Chen-Chi M; Wang, Ikai

    2011-12-01

    This study develops a technique for enhancing the electrical conductivity and optical transmittance of transparent double-walled carbon nanotube (DWNT) film. Silver nanoparticles were modified with a NH(2)(CH(2))(2)SH self-assembled monolayer terminated by amino groups and subsequent surface condensation that reacted with functionalized DWNTs. Ag nanoparticles were grafted on the surface of the DWNTs. The low sheet resistance of the resulting thin conductive film on a polyethylene terephthalate (PET) substrate was due to the increased contact areas between DWNTs and work function by grafting Ag nanoparticles on the DWNT surfaces. Increasing the contact area between DWNTs and work function improved the conductivity of the DWNT-Ag thin films. The prepared DWNT-Ag thin films had a sheet resistance of 53.4 Ω/sq with 90.5% optical transmittance at a 550 nm wavelength. After treatment with HNO(3) and annealing at 150 °C for 30 min, a lower sheet resistance of 45.8 Ω/sq and a higher transmittance of 90.4% could be attained. The value of the DC conductivity to optical conductivity (σ(DC)/σ(OP)) ratio is 121.3. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Integrated Ternary Bioinspired Nanocomposites via Synergistic Toughening of Reduced Graphene Oxide and Double-Walled Carbon Nanotubes.

    Science.gov (United States)

    Gong, Shanshan; Cui, Wei; Zhang, Qi; Cao, Anyuan; Jiang, Lei; Cheng, Qunfeng

    2015-12-22

    With its synergistic toughening effect and hierarchical micro/nanoscale structure, natural nacre sets a "gold standard" for nacre-inspired materials with integrated high strength and toughness. We demonstrated strong and tough ternary bioinspired nanocomposites through synergistic toughening of reduced graphene oxide and double-walled carbon nanotube (DWNT) and covalent bonding. The tensile strength and toughness of this kind of ternary bioinspired nanocomposites reaches 374.1 ± 22.8 MPa and 9.2 ± 0.8 MJ/m(3), which is 2.6 and 3.3 times that of pure reduced graphene oxide film, respectively. Furthermore, this ternary bioinspired nanocomposite has a high conductivity of 394.0 ± 6.8 S/cm and also shows excellent fatigue-resistant properties, which may enable this material to be used in aerospace, flexible energy devices, and artificial muscle. The synergistic building blocks with covalent bonding for constructing ternary bioinspired nanocomposites can serve as the basis of a strategy for the construction of integrated, high-performance, reduced graphene oxide (rGO)-based nanocomposites in the future.

  17. Electrochemical characterization of single-walled carbon nanotubes for electrochemical double layer capacitors using non-aqueous electrolyte

    International Nuclear Information System (INIS)

    Ruch, P.W.; Koetz, R.; Wokaun, A.

    2009-01-01

    Single-walled carbon nanotubes (SWCNTs) were investigated by cyclic voltammetry and electrochemical impedance spectroscopy in a non-aqueous electrolyte, 1 M Et 4 NBF 4 in acetonitrile, suitable for supercapacitors. Further, in situ dilatometry and in situ conductance measurements were performed on single electrodes and the results compared to an activated carbon, YP17. Both materials show capacitive behavior characteristic of high surface area electrodes for supercapacitors, with the maximum full cell gravimetric capacitance being 34 F/g for YP17 and 20 F/g for SWCNTs at 2.5 V with respect to the total active electrode mass. The electronic resistance of SWCNTs and activated carbon decreases significantly during charging, showing similarities of the two materials during electrochemical doping. The SWCNT electrode expands irreversibly during the first electrochemical potential sweep as verified by in situ dilatometry, indicative of at least partial debundling of the SWCNTs. A reversible periodic swelling and shrinking during cycling is observed for both materials, with the magnitude of expansion depending on the type of ions forming the double layer.

  18. Plus energy house. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Yde, L.

    1996-05-01

    A description of a demonstration project, located near Viborg in Denmark, involving a 400 m{sup 2} house with low energy consumption which has a 200 m{sup 2} living/working area, a 240 m{sup 2} mobile insulated glass facade and a solar greenhouse of 200 m{sup 2} which in addition to plant production can be used for recreational purposes. Humidity in the greenhouse is regulated by heat pumps condensing the water-laden air and thus producing hot water for space heating. The heat pumps maintain a 70% relative humidity in the greenhouse and surplus heat to the amount of 300 kWh/m{sup 2} of glass facade area is produced annually. Excess heat to the amount of 75.000 kWh is available for space heating in adjoining houses. The glazed roof of the house and greenhouse is constructed of two layers of tempered glass. The 20 cm space between the layers, when filled with polystyrene beads, provides thermal insulation equal to that of traditionally insulated outer house-walls. The beads can be sucked in and out of the roof space and can also be used for shading during the summer. It is concluded that the house (400 m{sup 2}) consumes the same quantity of energy as houses of a similar size and at the same time produces 300 kWh/m{sup 2} p.a. with the glass south facade, corresponding to what a solar collector produces per m{sup 2}. (AB)

  19. Comparison between ARIMA and DES Methods of Forecasting Population for Housing Demand in Johor

    Directory of Open Access Journals (Sweden)

    Alias Ahmad Rizal

    2016-01-01

    Full Text Available Forecasting accuracy is a primary criterion in selecting appropriate method of prediction. Even though there are various methods of forecasting however not all of these methods are able to predict with good accuracy. This paper presents an evaluation of two methods of population forecasting for housing demand. These methods are Autoregressive Integrated Moving Average (ARIMA and Double Exponential Smoothing (DES. Both of the methods are principally adopting univariate time series analysis which uses past and present data for forecasting. Secondary data obtained from Department of Statistics, Malaysia was used to forecast population for housing demand in Johor. Forecasting processes had generated 14 models to each of the methods and these models where evaluated using Mean Absolute Percentage Error (MAPE. It was found that 14 of Double Exponential Smoothing models and also 14 of ARIMA models had resulted to 1.674% and 5.524% of average MAPE values respectively. Hence, the Double Exponential Smoothing method outperformed the ARIMA method by reducing 4.00 % in forecasting model population for Johor state. These findings help researchers and government agency in selecting appropriate forecasting model for housing demand.

  20. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D.; Wiehagen, J.

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

  1. Measured airtightness of twenty-four detached houses over periods of up to three years

    Energy Technology Data Exchange (ETDEWEB)

    Prowskiw, G.

    1992-05-01

    A three year field study of 20 energy efficient houses and four conventional dwellings was conducted to evaluate the performance of their building envelope systems. Ten of the houses were built with polyethylene air barriers and 14 using the airtight drywall approach (ADA). All were newly built and used dry wood for framing members, i.e. with a wood moisture content (WMC) below 19%. Building envelope performace was evaluated by developing a comprehensive monitoring program which included measurements of wall, attic and floor joist WMC levels, detailed thermographic examinations and regular airtightness testing. Over 13,000 WMC measurements were performed, 1013 thermographic images recorded and 167 airtightness tests conducted. Both the energy efficient and conventional building envelope systems performed satisfactory manner although fewer problems were found in the energy efficient houses. Lower mean WMC levels were measured in the walls and attics and fewer WMC excursions above 19% were recorded. The energy efficient houses also displayed fewer thermographic anomalies, particulary those of a severe nature. The energy efficient houses were found to be more airtight. No evidence of envelope degradation was found in the energy efficient houses. Both the polyethylene air barriers and the ADA system demonstrated predominately stable WMC levels, thermographic characteristics and airtightness. The building envelopes constructed using polyethylene barriers generally performed in a superior fashion to those which used ADA, although both systems provided satisfactory performance. WMC levels were slightly lower in the polyethylene houses as were the number of thermographic faults, particularly those of a severe nature. 11 refs., 28 figs., 10 tabs.

  2. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D. [Home Innovation Research Labs, Upper Marlboro, MD (United States); Wiehagen, J. [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate.

  3. Long-term follow-up of total abdominal wall reconstruction for prune belly syndrome.

    Science.gov (United States)

    Lesavoy, Malcolm A; Chang, Eric I; Suliman, Ahmed; Taylor, Jason; Taylor, James; Kim, Sara E; Ehrlich, Richard M

    2012-01-01

    Prune belly syndrome is a rare, congenital condition that consists of a major deficiency or hypoplasia of the abdominal wall musculature, bilateral cryptorchidism, and genitourinary tract malformations. Reconstruction of the abdominal wall in these patients has presented a challenge to plastic surgeons throughout the years. The authors previously described a technique for total abdominal wall reconstruction that permitted simultaneous urinary tract reconstruction and bilateral orchiopexy. This innovative procedure used medial advancement of the fascia in a "double-breasted" fashion with preservation of the umbilicus. The authors reviewed their experience with this particular technique in one of the largest series of patients in the literature and the series with the longest follow-up. Twenty patients underwent total abdominal wall reconstruction with simultaneous urinary tract reconstruction and orchiopexy with a mean follow-up of 20.4 years. There were no major complications noted during this period, and all patients were extremely satisfied with their postoperative result. Total abdominal wall reconstruction using the double-breasted technique in patients with prune belly syndrome is a safe and durable procedure that achieves excellent cosmetic results. Therapeutic, IV.

  4. HERITAGE HOUSE MAINTENANCE USING 3D CITY MODEL APPLICATION DOMAIN EXTENSION APPROACH

    Directory of Open Access Journals (Sweden)

    Z. H. Mohd

    2017-11-01

    Full Text Available Heritage house is part of the architectural heritage of Malaysia that highly valued. Many efforts by the Department of Heritage to preserve this heritage house such as monitoring the damage problems of heritage house. The damage problems of heritage house might be caused by wooden decay, roof leakage and exfoliation of wall. One of the initiatives for maintaining and documenting this heritage house is through Three-dimensional (3D of technology. 3D city models are widely used now and much used by researchers for management and analysis. CityGML is a standard tool that usually used by researchers to exchange, storing and managing virtual 3D city models either geometric and semantic information. Moreover, it also represent multi-scale of 3D model in five level of details (LoDs whereby each of level give a distinctive functions. The extension of CityGML was recently introduced and can be used for problems monitoring and the number of habitants of a house.

  5. Partition wall structure in spent fuel storage pool and construction method for the partition wall

    International Nuclear Information System (INIS)

    Izawa, Masaaki

    1998-01-01

    A partitioning wall for forming cask pits as radiation shielding regions by partitioning inside of a spent fuel storage pool is prepared by covering both surface of a concrete body by shielding metal plates. The metal plate comprises opposed plate units integrated by welding while sandwiching a metal frame as a reinforcing material for the concrete body, the lower end of the units is connected to a floor of a pool by fastening members, and concrete is set while using the metal plate of the units as a frame to form the concrete body. The shielding metal plate has a double walled structure formed by welding a lining plate disposed on the outer surface of the partition wall and a shield plate disposed to the inner side. Then the term for construction can be shortened, and the capacity for storing spent fuels can be increased. (N.H.)

  6. Life cycle carbon emissions inventory of brick masonry and light steel framing houses in Brasilia: proposal of design guidelines for low-carbon social housing

    Directory of Open Access Journals (Sweden)

    Lucas Rosse Caldas

    Full Text Available Abstract This study evaluated the CO2eq emissions during the life cycle of two social housing projects in the city of Brasilia. A house of ceramic brick masonry was compared to a light steel framing one. The life cycle carbon emissions assessment (LCCO2A with a cradle-to-grave approach was used. The relation between the thermal performance of the wall systems and CO2eq emissions in the operational phase of the houses were evaluated using the DesignBuilder software. In addition, six scenarios composed of three CO2eq emission factors from the Brazilian electrical grid and two schedules of occupation of houses (full and part time were evaluated. The brick masonry house presented less CO2eq emissions than the light steel framing one. For both houses, the operational phase was the most significant regarding the total CO2eq emissions (50% to 70%, followed by the construction (20% to 30%, maintenance (11% to 20% and end-of-life (lower than 1% phases. The results also showed the importance of considering different CO2eq emission factors for the Brazilian context in the operational phase. Finally, based on the results obtained, design guidelines for low carbon social housing were proposed.

  7. Life Amongst the Rubbish: Middening and Conspicuous Consumption at Durrington Walls

    Directory of Open Access Journals (Sweden)

    Ben Chan

    2009-09-01

    Full Text Available Recent excavations at Durrington Walls have revealed a series of archaeological remains unparalleled in southern Britain. The most artefact-rich part of the site lies just outside the eastern entrance to the henge where a series of five houses was discovered flanking the Durrington Avenue. These houses were surrounded by a large midden that comprised a massive quantity of animal bone, pottery and worked flint. The number of articulated animal bones within the midden is suggestive of large-scale and 'wasteful' feasting episodes. This article presents the preliminary analysis of the worked stone from the midden. Durrington Walls represents a site of massive consumption: consumption of labour, wood, meat, pottery and worked stone. The material from the midden will be understood in these terms, as an act of massive, final and conspicuous consumption.

  8. Effect of turbulent flow on the double electric layer

    International Nuclear Information System (INIS)

    Rutten, F. van.

    1978-01-01

    The existence of the double electric layer could explain the local deposition of corrosion products in water cooled reactors. It is shown that turbulent flow tends to drive the ions away from the wall, disturbs the diffuse layer and enables the electric field to extend further into the liquid phase. This electric field attracts the particles to the walls by electrophoresis [fr

  9. CALCULATION REGARDING THERMAL TRANSFER THROUGH CLOSING ELEMENTS FOR A CATTLE SHELTER KEPT IN LOOSE HOUSING

    Directory of Open Access Journals (Sweden)

    Ancuţa JURCO

    2013-01-01

    Full Text Available This paper presents the calculation regarding thermal transmission due to closing elements for cattle shelter kept loose housing. The shelter is compound from 2 compartments, splitted in the middle by a cross alley. The compartments are divided in feeding area and resting area. The shelter has the opening of 16.35 m, total hall lenght is 40.95 m, with surface about 669.53 sqm and the maximum hight about 6.40 m. After analyzing the calculation of heat transfer through closing elements for a cattle shelter kept in loose housing show that the amount of heat lost through external walls with heterogeneous structure is minimal compared to the classical exterior wall with homogeneous structure.

  10. Design, Fabrication and Installation of the Charcoal Filter Housing in RIPF

    International Nuclear Information System (INIS)

    Kim, Min Jin; Lim, I. C.; Bang, H. S.

    2008-05-01

    In the Hot Cell Bank 3 of the Radioisotope Production Facility, production and dispense of I-131 solution and capsule that are used for the diagnosis and treatment of thyroid cancer are made. The original charcoal filter housings installed in 1994 and were utilized until the leakage of a very small amount of radio-iodine was found due to the erroneous installation of the charcoal filter in the filter housing. Thus the production of I-131 was discontinued until the repair and performance testing of the filter housing and the inspection by the regulatory body were finished. Although the production of I-131 was resumed, there was a desire for installing the brand-new charcoal filter housing which has an intrinsically safe design and no possibility of leakage. This report describes the design, fabrication and installation of brand-new charcoal filter housing. And also were described the dismantlement of the old housings, the assessment of the structural integrity of the shielding concrete wall and the installation of the shielding doors

  11. Passive houses in Sweden. Experiences from design and construction phase

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Ulla

    2008-07-01

    The sector of residential buildings and service organizations uses 36% of the total energy in Sweden. In June 2006, it was decided by the Swedish parliament that the energy use in residential buildings and premises should decrease by 20% per heated unit area before 2020. To reach this goal, more energy efficient buildings must be produced as well as energy efficient improvements must be performed on the existing building stock. One way to reduce the energy use in buildings is to build passive houses. A passive house is a mechanically ventilated building that with a highly insulated and air tight building envelope uses a minimum of energy for heating. The method used in this research is to practically participate in four passive house demonstration projects. The results expected are to find guiding principles and tools needed for passive house planning and make the system solutions usable for planning in more general terms. Joining as a part of the planning group; advice and help is given to architects, consultants and to the client. The demonstration projects studied are located in the south-west of Sweden. Three of the projects are new constructions and one is a renovation project. In the centre of Vanirom 40 rental apartments were built in 2005/2006 according to the passive house standard. Solar collectors on the roof contribute to the domestic hot water production. Every apartment has its own mechanical ventilation system with efficient heat recovery. Auxiliary heating is supplied by electricity. The load bearing structure were made of concrete and cast at site. The exterior walls and roof were made of wooden frame construction and mounted at site. The tenants moved in during summer 2006. The passive house project in Failure's consists of three houses with 12 rental apartments. The air is supplied by mechanical ventilation with an air to air heat exchanger, one in each apartment. The domestic hot water is prepared by solar collectors and auxiliary heating

  12. Shanghai housing reform. Program a burden on foreign investors.

    Science.gov (United States)

    Burke, F

    1991-09-23

    This document contains a summary of the Housing Reform Program created in Shanghai, China, in 1991, which requires monthly contributions of all employers and employees in Shanghai to a "Collective Reserve Fund." The program also applies to foreign investment enterprises and must be followed by all enterprises, regardless of any previous housing benefits that an enterprise may be providing its employees. Employers must deduct 5% from each employee's salary (with a minimum) monthly and must match that amount. The total is paid into an account in the employer's name with the People's Construction Bank of China. The total amount collected and matched for an employee is considered the property of the employee, but the account is administered by the employer as a collective trust account. Each employee's balance may be withdrawn upon retirement, leaving the area, or purchasing a home and leaving state-owned housing. Foreign investment enterprises contribute a reduced amount in recognition of the fact that they pay salaries that are higher than those of state enterprises. The Housing Reform Program also requires employers to contribute to doubled rent subsidies for public housing, requires workers to purchase housing construction bonds in order to be eligible for newly allocated public housing, calles for housing to be sold at favorable prices, and creates a system whereby mortgages can be obtained from the Collective Reserve Fund.

  13. The Trombe Wall during the 1970s: technological device or architectural space? Critical inquiry on the Trombe Wall in Europe and the role of architectural magazines

    Directory of Open Access Journals (Sweden)

    Piero Medici

    2017-12-01

    Full Text Available During the 1970s, before and after the international oil crisis of 1973, some European architectural periodicals were critical of standard construction methods and the architecture of the time. They described how architects and engineers reacted to the crisis, proposing new techniques and projects in order to intervene innovatively in the built environment, using energy and natural resources more efficiently. This article will provide a critical analysis of the role of architectural magazines of the time, describing the technological innovation of the Trombe Wall in Europe. It will treat when, how, and what specific aspects were described. It will also carry out a critical analysis of the Trombe Wall itself: about its performances, its evolution throughout the 1970s, its integration in different houses, and its influence on inhabitants’ behaviour. Using three houses as case studies, an analysis of the architects’ efforts to integrate the technology of the Trombe Wall with architectural elements such as shape, aesthetic, materiality, and natural light will be carried out. Though this article is historical in character, it aims to inform the contemporary debate, especially concerning issues of the built environment meeting the Paris agreement on climate change (AA, 2015.

  14. The Unfolded Protein Response Is Induced by the Cell Wall Integrity Mitogen-activated Protein Kinase Signaling Cascade and Is Required for Cell Wall Integrity in Saccharomyces cerevisiae

    OpenAIRE

    Scrimale, Thomas; Didone, Louis; de Mesy Bentley, Karen L.; Krysan, Damian J.

    2009-01-01

    The yeast cell wall is an extracellular structure that is dependent on secretory and membrane proteins for its construction. We investigated the role of protein quality control mechanisms in cell wall integrity and found that the unfolded protein response (UPR) and, to a lesser extent, endoplasmic reticulum (ER)-associated degradation (ERAD) pathways are required for proper cell wall construction. Null mutation of IRE1, double mutation of ERAD components (hrd1Δ and ubc7Δ) and ire1Δ, or expres...

  15. Systematic study on synthesis and purification of double-walled carbon nanotubes synthesized via CVD

    Science.gov (United States)

    Jedrzejewska, A.; Kalenczuk, R. J.; Mijowska, E.

    2011-12-01

    Carbon nanotubes have unique properties, such as thermal and electrical conductance, which could be useful in the fields of aerospace, microelectronics and biotechnology. However, these properties may vary widely depending on the dimensions, uniformity and purity of the nanotube. Nanotube samples typically contain a significant percentage of more allotropes forms of carbon as well as metal particles left over from catalysts used in manufacturing. Purity characterization of double-walled carbon nanotubes (DWCNTs) is an increasingly popular topic in the field of carbon nanotechnology. In this study, DWCNTs were synthesized in a catalytic reaction, using Fe:MgO as catalyst and methane or methane/ethanol as carbon feedstock for chemical vapor deposition (CVD). The addition of ethanol as carbon feedstock allowed to investigate the influence of oxygen on the sample quality. The purification of the as-produced material from the metallic particles and the catalyst support was performed by sonication in an acid solution. The influence of the duration of the acid treatment using ultrasound on the sample purity was investigated, and the optimal value of this parameter was found. Transmission electron microscopy (TEM) images confirmed the removal of impurities and served to elucidate the morphology of the samples. The purity of carbon nanotubes was analyzed using thermal gravimetric analysis (TGA). The Raman spectra of the samples, as a measure of the concentration of defects, were also reported.

  16. The toilet sanitation management to meet healthy house standards

    Science.gov (United States)

    Studyanto, Anung B.; Musfiroh, Mujahidatul; Sholahuddin

    2018-03-01

    To increase the community participation in the toilet sanitation management at house to making a house according the healthy house standart. The toilet sanitation management is becoming complex with increasing population growth, and limited land for sanitation. The community participation determines the success of the toilet sanitation management and improving the health status of the community. This study used an observation method for the availability of latrines according the healthy house criteria, spatial layout and pit layout that meet health and safety standards. Spatial and layout include bathroom area, type of material used for wall and floor bathroom, type of latrine, distance the waste storage distance with water source, and sewerage. The respondents in this study are the people who live in Jaten Village taken by accidental sampling. The number of respondents in this study were 15 respondents.This study shows that all respondents (100%) already have toilet and 8 respondents (53%) have a good toilet sanitation management. Respondents have provided latrines as an effort to manage household waste and according the healthy house standart. The latrine spatial plan has been well implemented, but the latrine layout plan has not been properly.

  17. Classification of Inheritance Shop Houses in George Town, Penang - UNESCO World Heritage Site

    Directory of Open Access Journals (Sweden)

    Rozliani Mansor

    2012-09-01

    Full Text Available Shop house is an urban terrace house attribute of Asian towns from the 18 th century which usually integrates a shop or business premise on the ground floor whilst the family dwells on the upper level, providing both ease and safety. The shop house might also be used entirely as dwelling quarters. Shop houses are constructed in rows and each row is arranged in blocks enclosed within a grid of main roads, back lanes and side roads. A shop house is usually two or three storeys high and is long and narrow, sharing a party wall with neighbours on either side. The Penang shop house is a ideal paradigm of a green building, using materials that are locally obtainable such as lime, clay stone and timber and suited to local geology and weather conditions. Shop houses also possessing architectural characteristics such as air vents and air-well that assist with natural ventilation and cooling. This paper will discuss categories and styles of the shop houses in historic city of George Town which can be divided into nine major groups.

  18. Bioinspired metal-cell wall-metal sandwich structure on an individual bacterial cell scaffold.

    Science.gov (United States)

    Zhang, Xiaoliang; Yu, Mei; Liu, Jianhua; Li, Songmei

    2012-08-25

    Pd nanoparticles were introduced to individual Bacillus cells and dispersedly anchored on both the inside and outside of the cell walls. The anchored nanoparticles served as "seeds" to drive the formation of double metallic layers forming a metal-cell wall-metal sandwich structure at the single-cell level.

  19. Wetting phase transition of two segregated Bose–Einstein condensates restricted by a hard wall

    Energy Technology Data Exchange (ETDEWEB)

    Thu, Nguyen Van [Department of Physics, Hanoi Pedagogical University No. 2, Hanoi (Viet Nam); Phat, Tran Huu [Vietnam Atomic Energy Commission, 59 Ly Thuong Kiet, Hanoi (Viet Nam); Song, Pham The, E-mail: thesong80@icloud.com [Tay Bac University, Son La (Viet Nam)

    2016-04-01

    Highlights: • System of two segregated Bose–Einstein condensates limited by a wall is studied. • Double-parabola approximation is applied to Gross–Pitaevskii theory. • Interface tension and wetting phase diagram are established. - Abstract: The wetting phase transition in the system of two segregated Bose–Einstein condensates (BECs) restricted by a hard wall is studied by means of the double-parabola approximation (DPA) applied to the Gross–Pitaevskii (GP) theory. We found the interfacial tension and the wetting phase diagram which depend weakly on the spatial restriction.

  20. Summary of detailed energy audit and building simulation on archetype sustainable house, Woodbridge ON

    Energy Technology Data Exchange (ETDEWEB)

    Fung, A. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Mechanical and Industrial Engineering; Dembo, A.; Zhou, J. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Architectural Science

    2009-07-01

    This paper described energy and audit and building simulations conducted on an archetype sustainable house located in Woodbridge, Ontario. The house formed part of a project to construct low energy, sustainable house designs for mass production. The 2 houses formed a duplex. House A was designed using current best design practices, while house B was equipped with advanced and innovative technologies not commonly used in residential constructions. Natural Resources Canada's (NRCan) HOT2000 residential building simulation program was used to evaluate the performance of both houses in the duplex. The simulation program demonstrated that house B performed more efficiently than house A. However, neither houses met their designed values. Significantly larger space heating and cooling loads were identified. The program showed that additional weather-stripping around doors, and caulking around windows will help to reduce the amount of draft in the houses. Assessments are also needed to measure heat losses from the common wall in the basement. It was concluded that the energy performance of the house can be optimized by using the appropriate sealing techniques throughout the building envelope. 2 refs., 1 tab.

  1. Prefabricated house in real estate business development in Jabodetabek

    Science.gov (United States)

    Gumilang Raksamala Basmara Putra, Raka; Susanto, Dalhar

    2017-12-01

    Within constructional technology prefabricated house is known as a house whose most of the components like walls, roofs, toilets, and structural cubes and columns are designated and produced in factory and assembled in site. Based on the experience in certain countries, prefabricated house has successfully entered commercial market. Prefabricated house shows a better infestation value than conventional houses. With prefabrication technology, building construction could be done faster and cost lower price, along with a good craftsmanship quality. Until now, Indonesia is still facing settlements issues and one of them is housing backlog whose amount revolves around 13 Million units. Prefabricated houses potentially solve the settlement issue in Indonesia in a much faster way. Yet the development of prefabricated house has not been accepted well in the market yet, both by the producers and the consumers. This writing talks about the result of the research about the causes of the lack of development in Indonesia when it comes to prefabricated houses though the method of comparison; comparing prefabricated house with conventional house when it comes to its 1) productivity rate, 2) consumers preference and 3) infestation performance. The data is collected through survey methods, interview and questionnaires. The result shows that even though the productivity rate when it comes to quality and time is high, prefabricated house shows low productivity when it comes to cost because it requires greater cost than it is in conventional houses. Other than that, the lack of business development when it comes to prefabricated houses is caused by the low preference of consumers toward the product- because of its inflexibility and monotonous appearance. The infestation of prefabricated house development shows a low NPV and IRR. With a more proper infestation approach such as mass constructions with effective numbers, good flexibility, and various appearances, prefabricated house

  2. Greenhouse effect in double-skin facade

    Energy Technology Data Exchange (ETDEWEB)

    Gratia, E.; Herde, A. de [Universite Catholique de Louvain, Architecture et Climat, Louvain-La-Neuve (Belgium)

    2007-02-15

    In these last years, a great deal of interest has been devoted to double-skin facades due to the advantages claimed by this technology (in terms of energy saving in the cold season, high-tech image, protection from external noise and wind loads). One of the great characteristics of the double-skin facade is the greenhouse effect. We identify the factors that influence the greenhouse effect. The identified parameters are solar radiation level, orientation and shading devices use, opaque wall/window proportion of the interior facade, wind speed, colour of shading devices and of interior facade, depth of the cavity of the double-skin, glazing type in the interior facade and openings in the double-skin. We analyze the impact of these parameters on the mean air temperature evolution in the cavity. After that analyse, the article answers the question: is greenhouse effect favourable? The answer is moderate according to the double-skin orientation. (author)

  3. Characterization of wall conditions in DIII-D

    International Nuclear Information System (INIS)

    Holtrop, K.L.; Jackson, G.L.; Kellman, A.G.; Lee, R.L.; West, W.P.; Wood, R.D.; Whyte, D.G.

    1996-10-01

    Wall conditioning in DIII-D is one of the most important factors in achieving reproducible high confinement discharges. For example, the very high confinement mode (VH-mode) was only discovered after boronization, a CVD technique to deposit a thin boron film over the entire surface of the tokamak. In order to evaluate wall conditions and provide a data base to correlate these wall conditions with tokamak discharge performance, a series of nominally identical reference VH-mode discharges (1.6 MA, 2.1 T, double-null diverted) were taken at various times during a series of experimental campaigns with evolving wall conditions. These reference discharges have allowed a quantitative determination of how the wall conditions have evolved. For instance, core carbon and oxygen levels in the VH-mode phase remains at historically low levels during the 1995 run year and there was also a steady decrease in the oxygen levels at plasma initiation during this period. The authors discuss the long term changes in low Z impurities and the effect of wall conditioning techniques such as boronization and baking on these impurities. In addition, the evolution of the deuterium recycling rates will be discussed

  4. Refurbishment of a Victorian terraced house for energy efficiency

    Science.gov (United States)

    Dimitriou, Angeliki

    The impacts of global warming are now obvious. The international community has committed itself to reduce CO2 emissions, the main contributor to the greenhouse effect, both at international and national levels. In the Kyoto Protocol signed in 1997, countries have committed to reduce their greenhouse gases emissions below their 1990 levels by the period 2008-2012. The UK specifically should reduce those emissions by 12.5%. Format reason, the UK has introduced a package of policies, which promote not only the use of renewable energy resources, but most importantly the reduction in energy use, with energy efficiency. Refurbishment of existing houses has and will contribute to the reduction of energy consumption. A Victorian mid-terraced house was studied in this report, and different refurbishment measures were tested, using two software programmes: TAS and SAP. The targets were to achieve certain levels of thermal comfort, to comply with the Building Regulation for building thermal elements and to achieve a high SAP rating. Then, the cost of each measure was calculated and its CO2 emissions were compared. Heat losses were mainly through the walls and roof. Roof and mainly wall refurbishment measures reduce the heating loads the most. Ground floor insulation does not contribute to the reduction of the heating loads, on the contrary it has detrimental effect in summer, where the cooling effect coming from the ground is being reduced. Window replacement achieves a very good performance in summer resulting in the reduction of overheating. Wall and roof insulation increase the SAP rating the most, between the building elements, but boiler replacement and upgrading of heating controls increase it more. According to the SAP rating, CO2 annual emissions are reduced the most by boiler replacement and then by wall and roof. The results given by the two softwares concerning which measure is more leads more to energy efficiency, are the same. Finally, if the measures which lead

  5. Effect of the fluorination technique on the surface-fluorination patterning of double-walled carbon nanotubes

    Directory of Open Access Journals (Sweden)

    Lyubov G. Bulusheva

    2017-08-01

    Full Text Available Double-walled carbon nanotubes (DWCNTs are fluorinated using (1 fluorine F2 at 200 °C, (2 gaseous BrF3 at room temperature, and (3 CF4 radio-frequency plasma functionalization. These have been comparatively studied using transmission electron microscopy and infrared, Raman, X-ray photoelectron, and near-edge X-ray absorption fine structure (NEXAFS spectroscopy. A formation of covalent C–F bonds and a considerable reduction in the intensity of radial breathing modes from the outer shells of DWCNTs are observed for all samples. Differences in the electronic state of fluorine and the C–F vibrations for three kinds of the fluorinated DWCNTs are attributed to distinct local surroundings of the attached fluorine atoms. Possible fluorine patterns realized through a certain fluorination technique are revealed from comparison of experimental NEXAFS F K-edge spectra with quantum-chemical calculations of various models. It is proposed that fluorination with F2 and BrF3 produces small fully fluorinated areas and short fluorinated chains, respectively, while the treatment with CF4 plasma results in various attached species, including single or paired fluorine atoms and –CF3 groups. The results demonstrate a possibility of different patterning of carbon surfaces through choosing the fluorination method.

  6. In-core assembly configuration having a dual-wall pressure boundary for nuclear reactor

    International Nuclear Information System (INIS)

    Todt, W.H. Sr.; Playfoot, K.C.

    1988-01-01

    This patent describes an in-core detector assembly of the type having an in-core part and an out-of-core part and having an elongated outer hollow housing tube with a wall thickness, an inner hollow calibration tube with a wall thickness and disposed concentrically within the outer tube to define an annular space therewith, and a plurality of discrete, circular, rod-like elements extending through the annular space, the improvement comprising: the elements having outer diameters and being of a number to substantially occupy the entire annular space of both the incore and out-of-core parts without significant voids between elements; each of the elements including at least an outer sheath and interior highly compacted mineral insulation for the entire length of the element; a first number of the elements also including center lead means connected to condition responsive element means in the in-core part of the length of the assembly and a second, remaining number of the elements being non-operating elements. The wall thickness of the housing tube and the wall thickness of the calibration tube, taken together with the diameter of the elements, provide a thickness dimension adequate to meet code primary pressure requirements for normal nuclear reactor in-core conditions, while the wall thickness of the calibration tube alone provides a thickness dimension less than adequate to meet such requirements

  7. Dose in a house built with contaminated wood

    International Nuclear Information System (INIS)

    Thomassin, A.

    2006-01-01

    This paper aims to assess the annual effective dose which could be received by a person living in a house built in France with wood from Belarus and contaminated by cesium 137 from Chernobylsk accident fallout. After the context be specified and the potential levels of radioactivity presented, an assessment of the annual effective dose is performed, based on an as realistic as possible scenario. After calculations it appears that the annual effective dose by external exposure potentially received by an inhabitant living in a house build with contaminated wood (pine or birch) at 1,000 Bq/kg is of the order of 1 mSv, due to external exposure to walls. This dose is not negligible, and could even be much more higher if wood from highly contaminated Belarusian areas is used for building houses. Projects of such wooden buildings should be studied with a particular attention to the characterization of the contamination. (N.C.)

  8. Dose in a house built with contaminated wood

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin, A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92 - Fontenay aux Roses (France)

    2006-07-01

    This paper aims to assess the annual effective dose which could be received by a person living in a house built in France with wood from Belarus and contaminated by cesium 137 from Chernobylsk accident fallout. After the context be specified and the potential levels of radioactivity presented, an assessment of the annual effective dose is performed, based on an as realistic as possible scenario. After calculations it appears that the annual effective dose by external exposure potentially received by an inhabitant living in a house build with contaminated wood (pine or birch) at 1,000 Bq/kg is of the order of 1 mSv, due to external exposure to walls. This dose is not negligible, and could even be much more higher if wood from highly contaminated Belarusian areas is used for building houses. Projects of such wooden buildings should be studied with a particular attention to the characterization of the contamination. (N.C.)

  9. Kissed awake. From timbered house to a KfW efficiency house monument; Wachgekuesst. Vom Fachwerkhaus zum KfW-Effizienzhaus Denkmal

    Energy Technology Data Exchange (ETDEWEB)

    Siegele, Klaus

    2013-02-15

    More than twenty years after acquisition of a courtyard area from the 18th century the owners decided to retrofit the building comprehensively and gently. This building is under preservation order. An interior thermal insulation using wood fibre boards with wall heating and clay plaster, framed windows as well as a new pellet-fuelled heating system halved the heat requirement and enhanced the indoor comfort in the gorgeous timbered house.

  10. Reconstitution of a secondary cell wall in a secondary cell wall-deficient Arabidopsis mutant.

    Science.gov (United States)

    Sakamoto, Shingo; Mitsuda, Nobutaka

    2015-02-01

    The secondary cell wall constitutes a rigid frame of cells in plant tissues where rigidity is required. Deposition of the secondary cell wall in fiber cells contributes to the production of wood in woody plants. The secondary cell wall is assembled through co-operative activities of many enzymes, and their gene expression is precisely regulated by a pyramidal cascade of transcription factors. Deposition of a transmuted secondary cell wall in empty fiber cells by expressing selected gene(s) in this cascade has not been attempted previously. In this proof-of-concept study, we expressed chimeric activators of 24 transcription factors that are preferentially expressed in the stem, in empty fiber cells of the Arabidopsis nst1-1 nst3-1 double mutant, which lacks a secondary cell wall in fiber cells, under the control of the NST3 promoter. The chimeric activators of MYB46, SND2 and ANAC075, as well as NST3, reconstituted a secondary cell wall with different characteristics from those of the wild type in terms of its composition. The transgenic lines expressing the SND2 or ANAC075 chimeric activator showed increased glucose and xylose, and lower lignin content, whereas the transgenic line expressing the MYB46 chimeric activator showed increased mannose content. The expression profile of downstream genes in each transgenic line was also different from that of the wild type. This study proposed a new screening strategy to identify factors of secondary wall formation and also suggested the potential of the artificially reconstituted secondary cell walls as a novel raw material for production of bioethanol and other chemicals. © The Author 2014. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists.

  11. Melting and evaporation analysis of the first wall in a water-cooled breeding blanket module under vertical displacement event by using the MARS code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Woo [Department of Nuclear Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of); Cho, Hyoung-Kyu, E-mail: chohk@snu.ac.kr [Department of Nuclear Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of); Park, Goon-Cherl [Department of Nuclear Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of); Im, Kihak [National Fusion Research Institute, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133 (Korea, Republic of)

    2017-05-15

    Highlights: • Material phase change of first wall was simulated for vertical displacement event. • An in-house first wall module was developed to simulate melting and evaporation. • Effective heat capacity method and evaporation model were proposed. • MARS code was proposed to predict two-phase phenomena in coolant channel. • Phase change simulation was performed by coupling MARS and in-house module. - Abstract: Plasma facing components of tokamak reactors such as ITER or the Korean fusion demonstration reactor (K-DEMO) can be subjected to damage by plasma instabilities. Plasma disruptions like vertical displacement event (VDE) with high heat flux, can cause melting and vaporization of plasma facing materials and burnout of coolant channels. In this study, to simulate melting and vaporization of the first wall in a water-cooled breeding blanket under VDE, one-dimensional heat equations were solved numerically by using an in-house first wall module, including phase change models, effective heat capacity method, and evaporation model. For thermal-hydraulics, the in-house first wall analysis module was coupled with the nuclear reactor safety analysis code, MARS, to take advantage of its prediction capability for two-phase flow and critical heat flux (CHF) occurrence. The first wall was proposed for simulation according to the conceptual design of the K-DEMO, and the heat flux of plasma disruption with a value of 600 MW/m{sup 2} for 0.1 s was applied. The phase change simulation results were analyzed in terms of the melting and evaporation thicknesses and the occurrence of CHF. The thermal integrity of the blanket first wall is discussed to confirm whether the structural material melts for the given conditions.

  12. Modeling Enclosure Design in Above-Grade Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, J. [Building Science Corporation, Westford, MA (United States); Ueno, K. [Building Science Corporation, Westford, MA (United States); Musunuru, S. [Building Science Corporation, Westford, MA (United States)

    2016-03-01

    Building Science Corporation modeled typically well-performing wall assemblies using Wärme und Feuchte instationär (WUFI) Version 5.3 software and demonstrated that these models agree with historic experience when calibrated and modeled correctly. This technical report provides a library of WUFI modeling input data and results. Within the limits of existing experience, this information can be generalized for applications to a broad population of houses.

  13. Investigation on Wall Panel Sandwiched With Lightweight Concrete

    Science.gov (United States)

    Lakshmikandhan, K. N.; Harshavardhan, B. S.; Prabakar, J.; Saibabu, S.

    2017-08-01

    The rapid population growth and urbanization have made a massive demand for the shelter and construction materials. Masonry walls are the major component in the housing sector and it has brittle characteristics and exhibit poor performance against the uncertain loads. Further, the structure requires heavier sections for carrying the dead weight of masonry walls. The present investigations are carried out to develop a simple, lightweight and cost effective technology for replacing the existing wall systems. The lightweight concrete is developed for the construction of sandwich wall panel. The EPS (Expanded Polystyrene) beads of 3 mm diameter size are mixed with concrete and developed a lightweight concrete with a density 9 kN/m3. The lightweight sandwich panel is cast with a lightweight concrete inner core and ferrocement outer skins. This lightweight wall panel is tested for in-plane compression loading. A nonlinear finite element analysis with damaged plasticity model is carried out with both material and geometrical nonlinearities. The experimental and analytical results were compared. The finite element study predicted the ultimate load carrying capacity of the sandwich panel with reasonable accuracy. The present study showed that the lightweight concrete is well suitable for the lightweight sandwich wall panels.

  14. Practical results of heat conservation in a housing estate scale-actions implemented by the Pradnik-Bialy-Zachod housing cooperative in Cracow

    Energy Technology Data Exchange (ETDEWEB)

    Piotrowski, L. [Pradnik-Bialy-Zachod Housing Cooperative, Cracow (Poland)

    1995-12-31

    There are 11,600,000 apartments occupied in Poland. More than 7,700,000 of these apartments are located in towns. Energy consumption for heating, ventilation and district hot water in residential housing reaches 40% of the national power balance. A portion of district heat distribution and relatively low energy efficiency is characteristic for Polish residential housing. Seventy five percent of apartments in towns are provided with central heating installations and 55% of the entire heat demand in Polish buildings is covered by district heating systems. The total installed heat power of these systems reaches 46,000 MW. The situation with regard to conservation in Polish residential housing is directly related to the legacy of central planning of the national economy and to the current phase of its re-organization to the market-oriented system. The standard value of the overall heat-transfer coefficient for external walls in Poland until 1980 was 1.16 W/m{sup 2}K; at present it is reduced to 0.55 W/m{sup 2}K. There are numerous reasons for the low energy efficiency in residential housing. These reasons are discussed.

  15. Performance analysis on natural energy autonomous house (HARBEMAN house); Shizen energy jiritsu house (HARBEMAN house) ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Fujino, T; Saito, T [Tohoku University, Sendai (Japan)

    1996-10-27

    To reduce fossil fuel consumption and CO2 emission, this article introduces an actually constructed natural energy autonomous house. It has a solar collector on the south roof for hot water supply and a sky radiator on the north roof for cooling water supply. The sky radiator uses radiation cooling phenomena into the space by electromagnetic wave through the window of atmosphere. This house also has an insulated tank with a capacity of 31 m{sup 3} in its underground. In the long-term heat storage mode, the heat is collected through the solar radiation during the period from summer to spring and is stored in the underground water tank, to use it for heating and hot water supply in winter. The heat can be recovered from the garbage waste incinerator. A gas fired auxiliary boiler is used for the shortage. In the long-term heat regeneration mode, the heat is regenerated through the sky radiator during the period from spring to summer and is stored in the underground water tank, to use it for cooling in summer. For the shortage, the water is cooled using a heat pump operated by the midnight power. The insulating performance is improved by using the pair glass in windows and the glass wool in the walls. Rain water is collected in a tank with a capacity of 2 m{sup 3}, to use it for toilet water. Annual energy and water saving is equivalent to 600,000 yen. 10 refs., 10 figs., 2 tabs.

  16. Solar cell options based on different geographical locations and wall inclination

    Science.gov (United States)

    Ma, Jie

    2018-05-01

    Two major trends in the development of contemporary solar energy science and technology [1]: First, the combination of light and point, the second is the combination of solar energy and construction. A large number of houses at the top of the installation of solar water heaters and other primary solar energy utilization equipment can no longer meet the needs of the majority of users, people pay more attention to the ventilation and heating of housing and solar power supply and other integrated multi-purpose building construction. Under the condition of simplification, this model gives the options of laying suitable solar cells for houses with different geographical positions and different inclination angles according to the actual situation. Based on our model, firstly we calculate the wall radiation according to the model (WRCM) to get the light radiation of the wall of the house, and then according to the power generation model (PGM), we can calculate the output of several types of batteries in the selected range. Finally, through the economic benefits mode l (EBM), we get the economic benefits of each type of battery in different places, and then we can choose the most suitable battery type. At the end of the article, we take Datong, Shanxi Province as an example, and substitute the relevant data from online search into the model. Compared with the actual situation, we verify that the model has good applicability.

  17. DOE ZERH Case Study: United Way of Long Island Housing Development Corporation, Patchogue, NY

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning affordable home in the mixed-humid climate that got HERS 40 without PV, -3 with PV, with 2x4 16: on center walls with R-13.5 dense packed cellulose and 1.5” polyiso rigid; basement with 2.5: polyiso on interior; unvented attic with R-48 ocsf under roof deck; ERV tied to wall hung boiler with hydro coil.

  18. The Wall On Gladstone Avenue

    Directory of Open Access Journals (Sweden)

    Pina MARCHESE

    2012-12-01

    Full Text Available "Since the house is on fire, Let us warm ourselves..." (Calabrian Proverb It all began in the village. We would wake up with the sun, we would rest our laboured bodies underneath the moon. Gli vecchi (old folks often told us: "In the end, all that will remain is our story. Nothing else really matters." This article "The Wall On Gladstone Avenue" will take you into a life of duality and how immigrants "press-on" to acquire knowledge and manifest meaning in a new land Canada.

  19. Radon in houses - identification of sources and pathways of transfer

    International Nuclear Information System (INIS)

    Robe, M.C.; Rannou, A.; Le Bronec, J.

    1992-01-01

    The Institut de Protection et de Surete Nucleaire (IPSN) is studying the remedial actions to reduce high concentration of radon in houses. The first step to know how to modify houses is to identify radon sources and pathways of transfer to upper floors. A pilot study in Brittany was designed to develop a simple method of diagnosis. This investigation was based on indoor and outdoor measurements of 222 Rn activity concentration in the air and 222 Rn area exhalation rate from the soils and walls, measurements of the potential alpha energy concentration of 222 Rn daughters and the ventilation rate. The structural characteristics of houses and the influence of the life style of the inhabitants were examined. Analysis of the results showed that a limited number of parameters can be selected for use in a rapid radon diagnosis. (author)

  20. Collapse and stability of single- and multi-wall carbon nanotubes

    International Nuclear Information System (INIS)

    Xiao, J; Liu, B; Huang, Y; Zuo, J; Hwang, K-C; Yu, M-F

    2007-01-01

    The collapse and stability of carbon nanotubes (CNTs) have important implications for their synthesis and applications. While nanotube collapse has been observed experimentally, the conditions for the collapse, especially its dependence on tube structures, are not clear. We have studied the energetics of the collapse of single- and multi-wall CNTs via atomistic simulations. The collapse is governed by the number of walls and the radius of the inner-most wall. The collapsed structure is energetically favored about a certain diameter, which is 4.12, 4.96 and 5.76 nm for single-, double- and triple-wall CNTs, respectively. The CNT chirality also has a strong influence on the collapsed structure, leading to flat, warped and twisted CNTs, depending on the chiral angle

  1. Evaluation of performance for solar house with Trombe wall. Part 5; Trombe hekishiki solar house no hyoka kenkyu (nichisekisan Trombe heki kyuhonetsuryo yosoku senzu no teian)

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, N [Nishimatsu Construction Co. Ltd., Kanagawa (Japan); Nakajima, Y [Kogakuin University, Tokyo (Japan); Watanabe, T [Tokyo Electric Power Service Co. Ltd., Tokyo (Japan); Abe, H [Ministry of Construction, Tokyo (Japan); Yamaga, K [Mitsubishi Estate Co. Ltd., Tokyo (Japan)

    1996-10-27

    A regression equation that can calculate the daily accumulated absorption heat of Trombe Wall was given, and the performance estimated chart of Trombe Wall in which the daily unit effect of Trombe Wall can be visually recognized was proposed. The absorption heat was multivariate-analyzed by two variables of solar radiation of that day and the previous day. The data obtained from simulation was used for analysis. The absorption heat was analyzed using the meteorological data at eight spots (Sapporo, Sendai, Niigata, Tokyo, Shizuoka, Kochi, Fukushima, and Kagoshima). In this case, the result of multivariate analysis almost coincided with the simulation result. A chart that predicts the absorption heat of Trombe Wall in eight cities from the daily accumulated global solar radiation of that day and the previous day was then created as the performance estimated chart of Trombe Wall. As a result, the solar radiation of that day little influences the absorption heat when the Trombe Wall increases in thickness. Conversely, the solar radiation of the previous day significantly influences the absorption heat. In future, an equivalent heat loss coefficient will be calculated from the performance estimated chart. 2 refs., 16 figs., 2 tabs.

  2. Automated quantification of bronchiectasis, airway wall thickening and lumen tapering in chest CT

    DEFF Research Database (Denmark)

    Perez-Rovira, Adria; Kuo, Wieying; Petersen, Jens

    thickness and accompanying artery radius), and inter-branch Lumen-Ratio (LR, ratio between a branch's lumen and its parent branch lumen radius, a tapering measurement) were computed. Because CF-related structural abnormalities only affect a portion of branches, the 75th percentile was used as summarising......Purpose: To automatically quantify airway structural properties visualised on CT in children with cystic fibrosis (CF) and controls, including: bronchiectasis, airway wall thickening, and lumen tapering. Methods and materials: The 3D surface of the airway lumen, outer wall, and bronchial arteries...... were obtained using a fully automatic, in-house developed, segmentation method. Subsequently, for each detected airway branch, the Airway-Artery Ratio (AAR, ratio between airway outer wall and accompanying artery radius, a bronchiectasis measurement), Wall-Artery Ratio (WAR, ratio between airway wall...

  3. Acceptance criteria for non-destructive examination of double-shell tanks

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-09-01

    This supporting document provides requirements for acceptance of relevant indications found during non-destructive examination of double-shell tanks (DSTs) at Hanford 200 areas. Requirements for evaluation of relevant indications are provided to determine acceptability of continued safe operation of the DSTs. Areas of the DSTs considered include the tank wall vapor space, liquid-vapor interface, wetted tank wall, sludge-liquid interface, and the knuckle region

  4. Overview of impurity control and wall conditioning in NSTX

    Energy Technology Data Exchange (ETDEWEB)

    KUGEL,H.W.; MAINGI,R.; BELL,M.; BLANCHARD,W.; GATES,D.; JOHNSON,D.; KAITA,R.; KAYE,S.; MARQUEDA,R.; MENARD,J.; MUELLER,D.; ONO,M.; PENG,Y-K.M.; RAMAN,R.; RAMSEY,A.; ROQUEMORE,A.; SKINNER,C.; SABBAGH,S.; STUTMAN,D.; WAMPLER,WILLIAM R.; WILSON,J.R.; ZWEBEN,S.

    2000-05-25

    The National Spherical Torus Experiment (NSTX) started plasma operations in February 1999, and promptly achieved high current, inner wall limited, double null, and single null plasma discharges, initial Coaxial Helicity Injection, and High Harmonic Fast Wave results. NSTX is designed to study the physics of Spherical Tori (ST) in a device that can produce non-inductively sustained high-{beta} discharges in the 1 MA regime and to explore approaches toward a small, economical high power density ST reactor core. As expected, discharge reproducibility and performance were strongly affected by wall conditions. In this paper, the authors describe the internal geometry, and initial plasma discharge, impurity control, wall conditioning, erosion, and deposition results.

  5. On film quality in barium-air double contrast colon study

    International Nuclear Information System (INIS)

    Rhu, Sang Hyung; Rhee, Jae Ho; Kim, Hai Sung; Cheung, Hwan

    1984-01-01

    The colon double contrast study provides valuable diagnostic information by means of appropriate control of Kvp and mAa when making double contrast image by injecting air into the colon after coating the colon wall by appropriately diluted Barium solution. The following experiments were performed the results of which allowed to improve the quality of film in barium-air double contrast colon study: (1) Do the pictures have uniform density when measured with a densitometer from three measuring points established in the picture by changing Kvp and mAs depending on the thickness of the patient? (2) Is the quality of the picture improved by being compensated from the adjacent area when using a wedge filter in routine check lateral decubitus and erect view? (3) What is the optimum dilution of barium solution which gives the best result for colon wall coating? The above experiments revealed that as the patient's thickness increased, it should be considered to increase mAs as well as Kvp and a wedge filter could give diagnostically very informative pictures in routine-check lateral decubitus and erect view. And 70-80% solution of Barium-water mixture provided the best quality of double contrast image

  6. Determination of the Airborne Sound Insulation of a Straw Bale Partition Wall

    Science.gov (United States)

    Teslík, Jiří; Fabian, Radek; Hrubá, Barbora

    2017-06-01

    This paper describes the results of a scientific project focused on determining of the Airborne Sound Insulation of a peripheral non-load bearing wall made of straw bales expressed by Weighted Sound Reduction Index. Weighted Sound Reduction Index was determined by measuring in the certified acoustic laboratory at the Faculty of Mechanical Engineering at Brno University of Technology. The measured structure of the straw wall was modified in combinations with various materials, so the results include a wide range of possible compositions of the wall. The key modification was application of plaster on both sides of the straw bale wall. This construction as is frequently done in actual straw houses. The additional measurements were performed on the straw wall with several variants of additional wall of slab materials. The airborne sound insulation value has been also measured in separate stages of the construction. Thus it is possible to compare and determinate the effect of the single layers on the airborne sound insulation.

  7. Determination of the Airborne Sound Insulation of a Straw Bale Partition Wall

    Directory of Open Access Journals (Sweden)

    Teslík Jiří

    2017-06-01

    Full Text Available This paper describes the results of a scientific project focused on determining of the Airborne Sound Insulation of a peripheral non-load bearing wall made of straw bales expressed by Weighted Sound Reduction Index. Weighted Sound Reduction Index was determined by measuring in the certified acoustic laboratory at the Faculty of Mechanical Engineering at Brno University of Technology. The measured structure of the straw wall was modified in combinations with various materials, so the results include a wide range of possible compositions of the wall. The key modification was application of plaster on both sides of the straw bale wall. This construction as is frequently done in actual straw houses. The additional measurements were performed on the straw wall with several variants of additional wall of slab materials. The airborne sound insulation value has been also measured in separate stages of the construction. Thus it is possible to compare and determinate the effect of the single layers on the airborne sound insulation.

  8. Gravitational double layers

    International Nuclear Information System (INIS)

    Senovilla, José M M

    2014-01-01

    I analyze the properties of thin shells through which the scalar curvature R is discontinuous in gravity theories with Lagrangian F(R) = R − 2Λ + αR 2 on the bulk. These shells/domain walls are of a new kind because they possess, in addition to the standard energy–momentum tensor, an external energy flux vector, an external scalar pressure/tension and, most exotic of all, another energy–momentum contribution resembling classical dipole distributions on a shell: a double layer. I prove that all these contributions are necessary to make the entire energy–momentum tensor divergence-free. This is the first known occurrence of such a type of double layer in a gravity theory. I present explicit examples in constant-curvature five-dimensional bulks, with a brief study of their properties: new physical behaviors arise. (fast track communications)

  9. Entry of soil gas and radon into houses

    International Nuclear Information System (INIS)

    Andersen, C.E.

    1992-04-01

    Entry of soil gas and radon into houses has been investigated by experiments conducted at radon test structures and numerical or analytical modelling. The numerical model solves the steady-state equations for Darcy flow of soil-gas and combined diffusive and advective transport of radon. Model calculations were compared with results from field experiments conducted at Risoe National Laboratory, and it was found that there was good agreement between measured and modelled pressure coupling and radon concentration profiles. Discrepancies regarding absolute values of soil-gas entry rates and radon concentrations were observed. The numerical model has been used to study the importance of soil and building related factors on radon entry rates into slab-on-grade houses. It was found that, for a house with a 3 mm perimeter crack along the floor-wall joint, the entry was mainly determined by the soil permeability and building related factors such as house depressurization and presence of a capillary breaking layer of gravel below the slab. In a house with a bare soil floor, the diffusivity of the soil was found to be of principal importance for the entry rate even for moderate permeabilities. An analytical model was developed for the purpose of studying soil-gas entry rates into houses in response to non-static driving forces. It is based on the analogy between a 'buried drain' and a basement house with a perimeter crack. The structure was depressurized sinusoidally in time and the frequency dependent pressure couplings were measured. There was fairly good agreement between theoretical and experimental results. (LN) (26 tabs., 30 ills., 66 refs.)

  10. The tubular separate first wall for ITER EDA

    International Nuclear Information System (INIS)

    Pizzuto, A.; Riccardi, B.; Salpietro, E.

    1994-01-01

    The first wall is one of the most loaded plasma-facing components, the heat flux is such that the thermal stresses are the most important design concern. In addition, the First Wall shall resist the eddy current induced plasma disruption, the high pressure of the coolant without leaking ( -6 Torr-lit/sec.) and it should maintain its properties under fast neutron flux (dose up to 3 MW/m 2 ). The tubular solution is the most suitable one to cope with the thermal stresses, the use of double wall reduces the risk of leaks inside the vacuum vessel by avoiding the growth of a crack through both walls: the soft brazing in between walls stops the growth of a crack from one tube to the other. The eddy currents induced in the tubes are low and the Halo current flowing poloidally in the tubes exert a radial pressure which is supported by the blanket box via ad hoc supporting points provided in between first wall and blanket. Conclusions from the thermo-hydraulic analysis and the electromagnetic analysis will be presented including dynamic analysis. Also results of preliminary technological tests on coatings will be discussed

  11. Energy performance of the low-energy house in Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Svendsen, Svend

    2005-01-01

    by ventilation heat recovery (90% efficiency) specially designed for arctic conditions, by using thicker insulation in walls (300 mm) and roof/floor (350 mm), and by using solar hot water heating (3250 kWh/year). The building is intended to enhance sustainability in the building sector in Greenland....... energy gain, efficient ventilation system with heat recovery and solar heating. In this paper the results of a calculation of the energy consumption of low-energy house is presented. The calculation was done using the program BSim2002 [1] and a new weather test reference year based on climatic data......The object of the low-energy house in Sisimiut in Greenland was to build a house with an energy consumption less than 80 kWh/m² corresponding to half the energy frame of the coming building code. Therefore the focus in this project has been on large insulation thicknesses, windows with high net...

  12. ELASTO-PLASTIC BEHAVIOR OF RC FRAMES COMPOSED OF STEEL JACKETTED RC SHORT COLUMNS AND SPANDREL WALLS

    OpenAIRE

    Nasruddin

    2012-01-01

    This experimental study is a part of the investigation on the seismic design method for Double Tubes Hybrid System (DTHS) for buildings. This structural system consists of RC core walls as the interior tube, and the exterior frames composed of RC short columns and RC spandrel walls as the exterior tube. The RC core walls are designed as the Energy Dissipation Structural Walls (EDSW), which are composed of RC coupled shear walls linked by short steel H-shaped beams as the energy dissipation de...

  13. Making housing first happen: organizational leadership in VA's expansion of permanent supportive housing.

    Science.gov (United States)

    Kertesz, Stefan G; Austin, Erika Laine; Holmes, Sally K; Pollio, David E; Schumacher, Joseph E; White, Bert; Lukas, Carol VanDeusen

    2014-12-01

    While most organizational literature has focused on initiatives that transpire inside the hospital walls, the redesign of American health care increasingly asks that health care institutions address matters outside their walls, targeting the health of populations. The US Department of Veterans Affairs (VA)'s national effort to end Veteran homelessness represents an externally focused organizational endeavor. Our aim was to evaluate the role of organizational practices in the implementation of Housing First (HF), an evidence-based homeless intervention for chronically homeless individuals. This was an interview-based comparative case study conducted across eight VA Medical Centers (VAMCs). Front line staff, mid-level managers, and senior leaders at VA Medical Centers were interviewed between February and December 2012. Using a structured narrative and numeric scoring, we assessed the correlation between successful HF implementation and organizational practices devised according to the organizational transformation model (OTM). Scoring results suggested a strong association between HF implementation and OTM practice. Strong impetus to house Veterans came from national leadership, reinforced by Medical Center directors closely tracking results. More effective Medical Center leaders differentiated themselves by joining front-line staff in the work (at public events and in process improvement exercises), by elevating homeless-knowledgeable persons into senior leadership, and by exerting themselves to resolve logistic challenges. Vertical alignment and horizontal integration advanced at sites that fostered work groups cutting across service lines and hierarchical levels. By contrast, weak alignment from top to bottom typically also hindered cooperation across departments. Staff commitment to ending homelessness was high, though sustainability planning was limited in this baseline year of observation. Key organizational practices correlated with more successful

  14. Chalcone Synthase (CHS) Gene Suppression in Flax Leads to Changes in Wall Synthesis and Sensing Genes, Cell Wall Chemistry and Stem Morphology Parameters

    Science.gov (United States)

    Zuk, Magdalena; Działo, Magdalena; Richter, Dorota; Dymińska, Lucyna; Matuła, Jan; Kotecki, Andrzej; Hanuza, Jerzy; Szopa, Jan

    2016-01-01

    The chalcone synthase (CHS) gene controls the first step in the flavonoid biosynthesis. In flax, CHS down-regulation resulted in tannin accumulation and reduction in lignin synthesis, but plant growth was not affected. This suggests that lignin content and thus cell wall characteristics might be modulated through CHS activity. This study investigated the possibility that CHS affects cell wall sensing as well as polymer content and arrangement. CHS-suppressed and thus lignin-reduced plants showed significant changes in expression of genes involved in both synthesis of components and cell wall sensing. This was accompanied by increased levels of cellulose and hemicellulose. CHS-reduced flax also showed significant changes in morphology and arrangement of the cell wall. The stem tissue layers were enlarged averagely twofold compared to the control, and the number of fiber cells more than doubled. The stem morphology changes were accompanied by reduction of the crystallinity index of the cell wall. CHS silencing induces a signal transduction cascade that leads to modification of plant metabolism in a wide range and thus cell wall structure. PMID:27446124

  15. Traditional Values and their Adaptation in Social Housing Design: Towards a New Typology and Establishment of ‘Air House’ Standard in Malaysia

    Directory of Open Access Journals (Sweden)

    Mohd Firrdhaus Mohd Sahabuddin

    2015-07-01

    Full Text Available Large migration from rural areas to urban areas like Kuala Lumpur has led to some implications for economic, social and cultural development. This high population has placed enormous demand on the existing housing stocks, especially for low-income groups.  However, some issues arise, one of which is overheated indoor air temperature. This problem contributes to the high-energy usage that forces huge sums of money to be spent on cooling the house by using mechanical equipment. Therefore, this study focuses on thermal comfort in social housing, and incorporates traditional values into its design to achieve a certain measurement of natural ventilation in a house. From the study, the carbon emission and energy consumption for an air-conditioned house is 67%, 66% higher than a naturally ventilated house. Therefore, this research has come up with a new typology design, which has a large exposed wall area and full-length openings on the opposite walls to increase cross ventilation. At the end of this research, the measurement of thermal comfort for a naturally ventilated building called ‘Air House’ has been identified.

  16. High temperature battery. Hochtemperaturbatterie

    Energy Technology Data Exchange (ETDEWEB)

    Bulling, M.

    1992-06-04

    To prevent heat losses of a high temperature battery, it is proposed to make the incoming current leads in the area of their penetration through the double-walled insulating housing as thermal throttle, particularly spiral ones.

  17. Thermally adapted design strategy of colonial houses in Surabaya

    Science.gov (United States)

    Antaryama, I. G. N.; Ekasiwi, S. N. N.; Mappajaya, A.; Ulum, M. S.

    2018-03-01

    Colonial buildings, including houses, have been considered as a representation of climate-responsive architecture. The design was thought to be a hybrid model of Dutch and tropical architecture. It was created by way of reinventing tropical and Dutch architecture design principles, and expressed in a new form, i.e. neither resembling Dutch nor tropical building. Aside from this new image, colonial house does show good climatic responses. Previous researches on colonial house generally focus on qualitative assessment of climate performance of the building. Yet this kind of study tends to concentrate on building elements, e.g. wall, window, etc. The present study is designed to give more complete picture of architecture design strategy of the house by exploring and analysing thermal performance of colonial buildings and their related architecture design strategies. Field measurements are conducted during the dry season in several colonial building in Surabaya. Air temperature and humidity are both taken, representing internal and external thermal conditions of the building. These data are then evaluated to determine thermal performance of the house. Finally, various design strategies are examined in order to reveal their significant contributions to its thermal performance. Results of the study in Surabaya confirm findings of the previous researches that are conducted in other locations, which stated that thermal performance of the house is generally good. Passive design strategies such as mass effect and ventilation play an important role in determining performance of the building.

  18. The Relationship Between Surface Curvature and Abdominal Aortic Aneurysm Wall Stress.

    Science.gov (United States)

    de Galarreta, Sergio Ruiz; Cazón, Aitor; Antón, Raúl; Finol, Ender A

    2017-08-01

    The maximum diameter (MD) criterion is the most important factor when predicting risk of rupture of abdominal aortic aneurysms (AAAs). An elevated wall stress has also been linked to a high risk of aneurysm rupture, yet is an uncommon clinical practice to compute AAA wall stress. The purpose of this study is to assess whether other characteristics of the AAA geometry are statistically correlated with wall stress. Using in-house segmentation and meshing algorithms, 30 patient-specific AAA models were generated for finite element analysis (FEA). These models were subsequently used to estimate wall stress and maximum diameter and to evaluate the spatial distributions of wall thickness, cross-sectional diameter, mean curvature, and Gaussian curvature. Data analysis consisted of statistical correlations of the aforementioned geometry metrics with wall stress for the 30 AAA inner and outer wall surfaces. In addition, a linear regression analysis was performed with all the AAA wall surfaces to quantify the relationship of the geometric indices with wall stress. These analyses indicated that while all the geometry metrics have statistically significant correlations with wall stress, the local mean curvature (LMC) exhibits the highest average Pearson's correlation coefficient for both inner and outer wall surfaces. The linear regression analysis revealed coefficients of determination for the outer and inner wall surfaces of 0.712 and 0.516, respectively, with LMC having the largest effect on the linear regression equation with wall stress. This work underscores the importance of evaluating AAA mean wall curvature as a potential surrogate for wall stress.

  19. Numerical modeling and experimental validation of the acoustic transmission of aircraft's double-wall structures including sound package

    Science.gov (United States)

    Rhazi, Dilal

    In the field of aeronautics, reducing the harmful effects of acoustics constitutes a major concern at the international level and justifies the call for further research, particularly in Canada where aeronautics is a key economic sector, which operates in a context of global competition. Aircraft sidewall structure is usually of a double wall construction with a curved ribbed metallic skin and a lightweight composite or sandwich trim separated by a cavity filled with a noise control treatment. The latter is of a great importance in the transport industry, and continues to be of interest in many engineering applications. However, the insertion loss noise control treatment depends on the excitation of the supporting structure. In particular, Turbulent Boundary Layer is of interest to several industries. This excitation is difficult to simulate in laboratory conditions, given the prohibiting costs and difficulties associated with wind tunnel and in-flight tests. Numerical simulation is the only practical way to predict the response to such excitations and to analyze effects of design changes to the response to such excitation. Another kinds of excitations encountered in industrial are monopole, rain on the Roof and diffuse acoustic field. Deterministic methods can calculate in each point the spectral response of the system. Most known are numerical methods such as finite elements and boundary elements methods. These methods generally apply to the low frequency where modal behavior of the structure dominates. However, the high limit of calculation in frequency of these methods cannot be defined in a strict way because it is related to the capacity of data processing and to the nature of the studied mechanical system. With these challenges in mind, and with limitations of the main numerical codes on the market, the manufacturers have expressed the need for simple models immediately available as early as the stage of preliminary drafts. This thesis represents an attempt

  20. Cell wall ingrowths in nematode induced syncytia require UGD2 and UGD3.

    Directory of Open Access Journals (Sweden)

    Shahid Siddique

    Full Text Available The cyst nematode Heterodera schachtii infects roots of Arabidopsis plants and establishes feeding sites called syncytia, which are the only nutrient source for nematodes. Development of syncytia is accompanied by changes in cell wall structures including the development of cell wall ingrowths. UDP-glucuronic acid is a precursor of several cell wall polysaccharides and can be produced by UDP-glucose dehydrogenase through oxidation of UDP-glucose. Four genes in Arabidopsis encode this enzyme. Promoter::GUS analysis revealed that UGD2 and UGD3 were expressed in syncytia as early as 1 dpi while expression of UGD1 and UGD4 could only be detected starting at 2 dpi. Infection assays showed no differences between Δugd1 and Δugd4 single mutants and wild type plants concerning numbers of males and females and the size of syncytia and cysts. On single mutants of Δugd2 and Δugd3, however, less and smaller females, and smaller syncytia formed compared to wild type plants. The double mutant ΔΔugd23 had a stronger effect than the single mutants. These data indicate that UGD2 and UGD3 but not UGD1 and UGD4 are important for syncytium development. We therefore studied the ultrastructure of syncytia in the ΔΔugd23 double mutant. Syncytia contained an electron translucent cytoplasm with degenerated cellular organelles and numerous small vacuoles instead of the dense cytoplasm as in syncytia developing in wild type roots. Typical cell wall ingrowths were missing in the ΔΔugd23 double mutant. Therefore we conclude that UGD2 and UGD3 are needed for the production of cell wall ingrowths in syncytia and that their lack leads to a reduced host suitability for H. schachtii resulting in smaller syncytia, lower number of developing nematodes, and smaller females.

  1. 75 FR 4100 - Affirmative Fair Housing, Marketing (AFHM) Plan-Multifamily Housing, Affirmative Fair Housing...

    Science.gov (United States)

    2010-01-26

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5376-N-01] Affirmative Fair Housing, Marketing (AFHM) Plan-Multifamily Housing, Affirmative Fair Housing Marketing (AFHM) Plan-Single Family Housing and Affirmative Fair Housing Marketing (AFHM) Plan- Cooperatives/Condominiums AGENCY: Office of...

  2. Stability characteristics and structural properties of single- and double-walled boron-nitride nanotubes under physical adsorption of Flavin mononucleotide (FMN) in aqueous environment using molecular dynamics simulations

    International Nuclear Information System (INIS)

    Ansari, R.; Ajori, S.; Ameri, A.

    2016-01-01

    Graphical abstract: Structural properties and stability characteristics of single- and double-walled boron-nitride nanotubes functionalized with Flavin mononucleotide (FMN) in aqueous environment are investigated employing molecular dynamics simulations. - Highlights: • Structural and buckling analysis of boron-nitride nanotubes under physical adsorption of Flavin mononucleotide (FMN). • Gyration radius increases linearly as the weight percentage of FMN increases. • Presence of water molecules results in more expansion of FMN around BNNTs. • Critical buckling force of functionalized BNNTs is higher than that of pure BNNTs. • The critical strain of functionalized BNNTs is found to be lower than that of pure ones. - Abstract: The non-cytotoxic properties of Boron-nitride nanotubes (BNNTs) and the ability of stable interaction with biomolecules make them so promising for biological applications. In this research, molecular dynamics (MD) simulations are performed to investigate the structural properties and stability characteristics of single- and double-walled BNNTs under physical adsorption of Flavin mononucleotide (FMN) in vacuum and aqueous environments. According to the simulation results, gyration radius increases by rising the weight percentage of FMN. Also, the results demonstrate that critical buckling force of functionalized BNNTs increases in vacuum. Moreover, it is observed that by increasing the weight percentage of FMN, critical force of functionalized BNNTs rises. By contrast, critical strain reduces by functionalization of BNNTs in vacuum. Considering the aqueous environment, it is observed that gyration radius and critical buckling force of functionalized BNNTs increase more considerably than those of functionalized BNNTs in vacuum, whereas the critical strains approximately remain unchanged.

  3. F observable in double π{sup 0}-photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Garni, Stefanie [Department of Physics, University of Basel, CH-4056 Basel (Switzerland); Collaboration: A2-Collaboration

    2014-07-01

    The measurement of single and double polarization observables gives information about the different resonance contributions in the cross section and hence leads to a better understanding of the nucleon and its excited states. The double π{sup 0}-photoproduction is one of the most interesting reaction for the measurement of these observables. It allows to search for excited nucleon states which decay preferentially via cascades involving intermediate excited states. Furthermore, the background from non-resonant terms is small since the photon does not couple directly to neutral pions. Double π{sup 0}-photoproduction off a transversally polarized H-Butanol target has been measured using circularly polarized bremsstrahlung photons produced by MAMI-C with incident energies up to 1.5 GeV. The double π{sup 0} reaction was identified using a combined setup of the Crystal Ball colorimeter and a TAPS forward wall which results in an almost 4π acceptance. Preliminary results on the single polarization observable T and double polarization observable F are presented.

  4. Gas leakage rate through reinforced concrete shear walls: Numerical study

    International Nuclear Information System (INIS)

    Wang Ting; Hutchinson, Tara C.

    2005-01-01

    Unlined reinforced concrete shear walls are often used as 'tertiary boundaries' in the United States Department of Energy (DOE) to house dangerous gases. An unanticipated event, such as an earthquake, may cause gases stored inside the walls to disperse into the environment resulting in excess pollution. To address this concern, in this paper, a methodology to numerically predict the gas leakage rate through these shear walls under lateral loading conditions is proposed. This methodology involves finite element and flow rate analysis. Strain distributions are obtained from the finite element analysis, and then used to simulate the crack characteristics on the concrete specimen. The flow rate through the damaged concrete specimen is then estimated using flow rate formulas available from the literature. Results from an experimental specimen are used to evaluate the methodology, and particularly its robustness in the flow rate estimation

  5. Global Warming Implications of the Use of By-Products and Recycled Materials in Western Australia’s Housing Sector

    Science.gov (United States)

    Lawania, Krishna; Sarker, Prabir; Biswas, Wahidul

    2015-01-01

    Western Australia’s housing sector is growing rapidly and around half a million houses are expected to be built by 2030, which not only will result in increased energy and resources demand but will have socio-economic impacts. Majority of Western Australians live in detached houses made of energy intensive clay bricks, which have a high potential to generate construction and demolition (C&D) waste. Therefore, there is a need to look into the use of alternative materials and construction methods. Due to Western Australia’s temperate climate, concrete could not only offer a comfortable living space but an operational energy saving also can be achieved. This paper has assessed the global warming implications of cast in-situ concrete sandwich wall system as an alternative to clay brick walls (CBW) with partial replacement of cement in concrete with by-products such as fly ash (FA) and ground granulated blast furnace slag (GGBFS), natural aggregate (NA) with recycled crushed aggregate (RCA), natural sand (NS) with manufactured sand (MS) and, polyethylene terephthalate (PET) foam core as a replacement to polystyrene core for construction of a typical 4 × 2 × 2 detached house in Perth. Life cycle management (LCM) approach has been used to determine global warming reduction benefits due to the use of available by-products and recycled materials in Western Australian houses.

  6. Global Warming Implications of the Use of By-Products and Recycled Materials in Western Australia’s Housing Sector

    Directory of Open Access Journals (Sweden)

    Krishna Lawania

    2015-10-01

    Full Text Available Western Australia’s housing sector is growing rapidly and around half a million houses are expected to be built by 2030, which not only will result in increased energy and resources demand but will have socio-economic impacts. Majority of Western Australians live in detached houses made of energy intensive clay bricks, which have a high potential to generate construction and demolition (C&D waste. Therefore, there is a need to look into the use of alternative materials and construction methods. Due to Western Australia’s temperate climate, concrete could not only offer a comfortable living space but an operational energy saving also can be achieved. This paper has assessed the global warming implications of cast in-situ concrete sandwich wall system as an alternative to clay brick walls (CBW with partial replacement of cement in concrete with by-products such as fly ash (FA and ground granulated blast furnace slag (GGBFS, natural aggregate (NA with recycled crushed aggregate (RCA, natural sand (NS with manufactured sand (MS and, polyethylene terephthalate (PET foam core as a replacement to polystyrene core for construction of a typical 4 × 2 × 2 detached house in Perth. Life cycle management (LCM approach has been used to determine global warming reduction benefits due to the use of available by-products and recycled materials in Western Australian houses.

  7. Radon and radon progeny in 70 houses in the Tennessee Valley area: study design and measurement methods

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.; Monar, K.P.; Quillen, J.L.; Clark, C. Jr.; Doane, R.W.; Wallace, R.G.; Reed, R.P.

    1986-01-01

    Levels of radon and its short-lived airborne progeny are being measured in a year-long study of 70 houses in four states in the Tennessee Valley. Various methods were used to solicit volunteers with differing degrees of success. Criteria for selection of houses in the study included presence of a lower level with cement floor and one or more block walls in contact with the soil, absence of obvious indications of technologically enhanced sources of radium, and proximity to one of four cities (Knoxville, Chattanooga, Birmingham, or Florence). By design, most houses in the study are in the same neighborhood as at least one other house in the study. Houses range in age from newly constructed to about 40 years old. Most of the houses have more than 2000 square feet of finished floor space. The lower level encompasses a garage in most cases. More complete information pertaining to house characteristics will be gathered in the course of the study. 19 refs., 1 fig

  8. Verification of the Performance of a Vertical Ground Heat Exchanger Applied to a Test House in Melbourne, Australia

    Directory of Open Access Journals (Sweden)

    Koon Beng Ooi

    2017-10-01

    Full Text Available The ground heat exchanger is traditionally used as a heat source or sink for the heat pump that raises the temperature of water to about 50 °C to heat houses. However, in winter, the heating thermostat (temperature at which heating begins in the Australian Nationwide House Energy Rating Scheme (NatHERS is only 20 °C during daytime and 15 °C at night. In South-East Melbourne, the temperature at the bottom of a 50-meter-deep borehole has been recorded with an Emerson™ recorder at 17 °C. Melbourne has an annual average temperature of 15 °C, so the ground temperature increases by 2 °C per 50-m depth. A linear projection gives 23 °C at 200-m of depth, and as the average undisturbed temperature of the ground for a 400-m-deep vertical ground heat exchanger (VGHE. This study, by simulation and experimentation, aims to verify that the circulation of water in the VGHE’s U-tube to low-temperature radiators (LTRs could heat a house to thermal comfort. A literature review is included in the introduction. A simulation, using a model of a 60-m2 experimental house, shows that the daytime circulation of water in this VGHE/LTR-on-opposite-walls system during the 8-month cold half of the year, heats the indoors to NatHERS settings. Simulation for the cold half shows that this VGHE-LTR system could cool the indoors. Instead, a fan creating a cooling sensation of up to 4 °C is used so that the VGHE is available for the regeneration of heat extracted from the ground during the cold portion. Simulations for this hot portion show that a 3.4-m2 flat plate solar collector can collect more than twice the heat extracted from the ground in the cold portion. Thus, it can thus replenish the ground heat extracted for houses double the size of this 60-m2 experimental house. Therefore, ground heat is sustainable for family-size homes. Since no heat pump is used, the cost of VGHE-LTR systems could be comparable to systems using the ground source heat pump. Water

  9. Final results of double-shell tank 241-AY-102 ultrasonic inspection

    International Nuclear Information System (INIS)

    JENSEN, C.E.

    1999-01-01

    This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AY-102. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AY-102 primary tank wall and welds. The inspection found some indication of insignificant general and local wall thinning with no cracks detected

  10. Final results of double-shell tank 241-AN-105 ultrasonic inspection

    International Nuclear Information System (INIS)

    JENSEN, C.E.

    1999-01-01

    This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AN-105. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AN-105 primary tank wall primary knuckle, and secondary tank bottom. The inspection found some indication of general and local wall thinning with no cracks detected

  11. Proposal of a Self-baking Single-wall Design for the VI Section of the ATLAS Beam Pipe

    CERN Document Server

    Marco Olcese, MO

    2002-01-01

    A single-wall design for the VI section of the ATLAS beam vacuum chamber is presented. This design would allow for a major cost saving with respect to the current double-wall baseline. All the thermal implications and impact on the B-layer mudules are discussed.

  12. Role of Hydrophobic/Aromatic Residues on the Stability of Double-Wall β-Sheet Structures Formed by a Triblock Peptide.

    Science.gov (United States)

    Ozgur, Beytullah; Sayar, Mehmet

    2017-04-27

    Bioinspired self-assembling peptides serve as powerful building blocks in the manufacturing of nanomaterials with tailored features. Because of their ease of synthesis, biocompatibility, and tunable activity, this emerging branch of biomolecules has become very popular. The triblock peptide architecture designed by the Hartgerink group is a versatile system that allows control over its assembly and has been shown to demonstrate tunable bioactivity. Three main forces, Coulomb repulsion, hydrogen bonding and hydrophobicity act together to guide the triblock peptides' assembly into one-dimensional objects and hydrogels. It was shown previously that both the nanofiber morphology (e.g., intersheet spacing, formation of antiparallel/parallel β-sheets) and hydrogel rheology strictly depend on the choice of the core residue where the triblock peptide fibers with aromatic cores in general form shorter fibers and yield poor hydrogels with respect to the ones with aliphatic cores. However, an elaborate understanding of the molecular reasons behind these changes remained unclear. In this study, by using carefully designed computer based free energy calculations, we analyzed the influence of the core residue on the formation of double-wall fibers and single-wall β-sheets. Our results demonstrate that the aromatic substitution impairs the fiber cores and this impairment is mainly associated with a reduced hydrophobic character of the aromatic side chains. Such weakening is most obvious in tryptophan containing peptides where the fiber core absorbs a significant amount of water. We also show that the ability of tyrosine to form side chain hydrogen bonds plays an indispensable role in the fiber stability. As opposed to the impairment of the fiber cores, single-wall β-sheets with aromatic faces become more stable compared to the ones with aliphatic faces suggesting that the choice of the core residue can also affect the underlying assembly mechanism. We also provide an in

  13. A triple quantum dot in a single-wall carbon nanotube

    DEFF Research Database (Denmark)

    Grove-Rasmussen, Kasper; Jørgensen, Henrik Ingerslev; Hayashi, T.

    2008-01-01

    A top-gated single-wall carbon nanotube is used to define three coupled quantum dots in series between two electrodes. The additional electron number on each quantum dot is controlled by top-gate voltages allowing for current measurements of single, double, and triple quantum dot stability diagrams...

  14. Repair of an Endoscopic Retrograde Cholangiopancreatography-Related Large Duodenal Perforation Using Double Endoscopic Band Ligation and Endoclipping

    Directory of Open Access Journals (Sweden)

    Keunmo Kim

    2017-03-01

    Full Text Available Endoscopic closure techniques have been introduced for the repair of duodenal wall perforations that occur during endoscopic retrograde cholangiopancreatography (ERCP. We report a case of successful repair of a large duodenal wall perforation by using double endoscopic band ligation (EBL and an endoclip. Lateral duodenal wall perforation occurred during ERCP in a 93-year-old woman with acute calculous cholangitis. We switched to a forward endoscope that had a transparent band apparatus. A 2.0-cm oval-shaped perforation was found at the lateral duodenal wall. We repaired the perforation by sequentially performing double EBL and endoclipping. The first EBL was performed at the proximal edge of the perforation orifice, and two-thirds of the perforation were repaired. The second EBL, which also included the contents covered under the first EBL, repaired the defect almost completely. Finally, to account for the possible presence of a residual perforation, an endoclip was applied at the distal end of the perforation. The detection and closure of the perforation were completed within 10 minutes. We suggest that double EBL is an effective method for closure.

  15. Autonomous houses. Autonomous house

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, S. (Tokai University, Tokyo (Japan). Faculty of Engineering)

    1991-09-30

    Self-sufficiency type houses are outlined. On condition that people gain a certain amount of income in relation with the society, they self-suffice under the given environment, allowing themselves to accept a minimum of industrial products with small environmental load. Ordinary supply from outside of fossil energy and materials which depend on it is minimized. Types are classified into three: energy, energy materials and perfect self-sufficiency. A study project for environment symbiotic houses is progressing which is planned by the Ministry of Construction and Institute of Building Energy Conservation and is invested by a private company. Its target is making a house for halving an environmental load by CO{sub 2}, for the purpose of creating the environment symbiotic house which is nice to and in harmony with the global environment and human beings. As a part of the studies on energy-saving and resource conservation on houses, introduced is a plan of an autonomous house at Izu-Atagawa. The passive method and high thermal-insulation are used for air conditioning, and hot spring water for hot water supply. Electric power is generated by hydroelectric power generation using mountain streams and by solar cells. Staple food is purchased, while subsidiary food is sufficed. 17 refs., 4 figs., 1 tab.

  16. Remedial measures in Swedish and Norwegian houses - application of radon and radon decay product measurements

    International Nuclear Information System (INIS)

    Just, G.; Philipsborn, H. von; Matolin, M.; Molzahn, D.

    1998-01-01

    Houses and apartments in Sweden and Norway with excessive indoor radon concentrations were studied in detail with a variety of methods, standard and novel ones recently developed. For suitable remediation it is necessary to distinguish soil radon and exhalation from blue (porous) concrete. Our CARBOTEST-S is a simple, sensitive, in-situ method to quantify radon exhalation from existing walls, as well as radon permeability of different protective foils and final quality control of foils applied to existing walls. (orig.) [de

  17. Towards improved modeling of steel-concrete composite wall elements

    International Nuclear Information System (INIS)

    Vecchio, Frank J.; McQuade, Ian

    2011-01-01

    Highlights: → Improved analysis of double skinned steel concrete composite containment walls. → Smeared rotating crack concept applied in formulation of new analytical model. → Model implemented into finite element program; numerically stable and robust. → Models behavior of shear-critical elements with greater ease and improved accuracy. → Accurate assessments of strength, deformation and failure mode of test specimens. - Abstract: The Disturbed Stress Field Model, a smeared rotating crack model for reinforced concrete based on the Modified Compression Field Theory, is adapted to the analysis of double-skin steel-concrete wall elements. The computational model is then incorporated into a two-dimensional nonlinear finite element analysis algorithm. Verification studies are undertaken by modeling various test specimens, including panel elements subject to uniaxial compression, panel elements subjected to in-plane shear, and wall specimens subjected to reversed cyclic lateral displacements. In all cases, the analysis model is found to provide accurate calculations of structural load capacities, pre- and post-peak displacement responses, post-peak ductility, chronology of damage, and ultimate failure mode. Minor deficiencies are found in regards to the accurate portrayal of faceplate buckling and the effects of interfacial slip between the faceplates and the concrete. Other aspects of the modeling procedure that are in need of further research and development are also identified and discussed.

  18. Bubbles, Post-Crash Dynamics, and the Housing Market

    OpenAIRE

    Crocker H. Liu; Adam Nowak; Stuart Rosenthal

    2014-01-01

    This paper documents and explains previously unrecognized post-crash dynamics following the collapse of a housing bubble. A simple model predicts that speculative developers ensure stable pre-crash relative prices between small and large homes while their post-crash exit allows small-home relative values to fall. Evidence from Phoenix supports the model. Although home prices doubled 2004-2006, relative prices of small-to-large homes remained nearly constant but then plummeted post-crash. As s...

  19. Innova House - Ottawa`s advanced house

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-31

    A pilot program was developed to provide the housing industry with a means to field test innovative technologies, products and building systems, and to evaluate their overall performance. Under Canada`s Advanced House Program, ten demonstration houses were designed, built and monitored. Ottawa`s Innova House, was one of the ten houses built for this program. The innovative energy saving features of the house included (1) air distribution with small diameter ducts and an electronically commutated motor, a 2.6 kW grid-connected photovoltaic system, (3) an energy recovery ventilator (ERV) with free-cooling mode, (4) a 94 per cent efficient integrated gas heating and hot water system, (5) airtight drywall construction, (6) CFC-free exterior insulation, (7) a natural-gas-engine heat pump for air conditioning, (8) a prototype sealed combustion gas range and clothes dryer, and (9) a manifold plumbing system to conserve water. It was designed to consume one half of the energy consumed in an R-2000 home and one third of the energy of a conventional house. Several of the mechanical elements did not perform at expected levels, (lower than expected efficiencies from the heating and cooling systems and a malfunctioning ERV), nevertheless, overall performance of the house was still very close to the targets. The construction and operation of the house was described. tabs., figs.

  20. Some results from the demonstration of indoor radon reduction measures in block basement houses

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1989-01-01

    Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m 3 , and the results indicate that radon levels can be reduced substantially often below the U.S. Environmental Protection Agency (EPA) guideline of 148 Bq/m 3 , if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: (1) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or (2) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or the soil underneath the slab

  1. A new insight into opaque envelopes in a passive solar house: Properties and roles

    International Nuclear Information System (INIS)

    Long, Linshuang; Ye, Hong; Liu, Minghou

    2016-01-01

    Highlights: • A new insight into the opaque envelopes of a passive solar house was gained. • Five parts of envelopes, i.e., roof, south/east/west/north walls, were discussed. • Each part of envelopes were analyzed separately rather than treated as a whole. • Ideal properties of materials for each envelope are diverse from one another. • Differences are related to the envelopes’ leading roles as a heater or a cooler. - Abstract: Passive solar houses are effective solutions for minimizing the operating energy of buildings. The building envelopes of passive solar houses exert a significant influence on the degree of indoor thermal comfort. The focus of this study was the construction of high-performance opaque envelopes, i.e., the roof and walls, for a passive solar house, and a new conception of the envelopes from the perspective of the relation between the properties and roles was provided. The discussion was conducted based on a comprehensive range of envelope materials that were distinguished by the thermal conductivity and volumetric heat capacity. For the first time, each part of the envelopes was analyzed separately rather than considered as an entire envelope. By analyzing each envelope individually, the optimum properties of each envelope were found to be distinct from each other. The distinctions are determined by the dominant role of each envelope, which is associated with the location and absorbed solar irradiation. For summer or hot climate applications, when the dominant role is a cooler, the envelope, e.g., the south wall, should consist of materials with high thermal conductivity and large heat capacity; if a heater is the dominant role, the envelope, e.g., the roof, should consist of materials with low thermal conductivity. For winter or cold climate applications, the envelopes with a leading role of a heater or a cooler require materials with high or low thermal conductivity, respectively. Under the guidance of the results, a discussion

  2. Observation of Fermi Arc Surface States Induced by Organic Memristive/Memcapacitive Devices with a Double-Helical Polarized Single-Wall Nanotube Membrane for Direct Chelating with Matrix Matelloproteinase-2

    Directory of Open Access Journals (Sweden)

    E. T. CHEN

    2017-07-01

    Full Text Available Matrix Matelloproteinase-2 (MMP-2 plays a key role in many diseases. A new type of dual-functioning device was developed for fast, direct ultrasensitive detection of MMP-2. We report a memristive/memcapacitive device with vertex double-helical polarized biomimetic protein nanotubules forming double membranes with potential gradient mimicking mitochondria’s inner double membrane has developed. We also report Fermi arcs with nodes on the surface of the nanostructured membrane was observed at the first time by using a 3D real-time - energy-current dynamic mapping method based on data obtained from the Cyclic Voltammetry (CV method. The memristive/memcapacitive device comprises a cross- linked organic polymer having single-wall cross-bar polarized nanotube self-assembling membrane (SAM on a gold chip, under an applied potential, a pair of vertex double- helical circular current flow induced the Fermi arcs states occurrence and these Fermi arcs promoted a direct chelating with zinc ions of the MMP-2 to become possible without any antibody, tracer, or reagent used at room temperature was accomplished. We observed the pair of Dirac Cones became alignment and strengthened with each other in the presence of MMP-2 compared without MMP-2. The MMP-2 can be detected with ag/mL level sensitivity and the value of Detection of Limits (DOL reached orders of magnitude lower than published reports with simplified procedures by a Chronoamperometry (CA method and a Double Step Chronopotentiometry (DSCPO method using NIST SRM 965A standard human serum, respectively. The results show a feasible application for developing the commercial fast and real-time MMP monitoring devices for various diseases.

  3. Environmental Assessment: Military Housing Privatization Initiative Schriever Air Force Base, Colorado

    Science.gov (United States)

    2006-08-24

    community features SAFB has requested include the following: secure perimeter wall for aesthetics and security, community center/ clubhouse , swimming pool...Proposed Action Under the proposed action, 269 family housing units would be constructed on approximately 150 acres of what is now categorized as open...incremental impact of the action when added to other past, present, and reasonably foreseeable future actions regardless of what agency (Federal or non

  4. Fast mean and variance computation of the diffuse sound transmission through finite-sized thick and layered wall and floor systems

    Science.gov (United States)

    Decraene, Carolina; Dijckmans, Arne; Reynders, Edwin P. B.

    2018-05-01

    A method is developed for computing the mean and variance of the diffuse field sound transmission loss of finite-sized layered wall and floor systems that consist of solid, fluid and/or poroelastic layers. This is achieved by coupling a transfer matrix model of the wall or floor to statistical energy analysis subsystem models of the adjacent room volumes. The modal behavior of the wall is approximately accounted for by projecting the wall displacement onto a set of sinusoidal lateral basis functions. This hybrid modal transfer matrix-statistical energy analysis method is validated on multiple wall systems: a thin steel plate, a polymethyl methacrylate panel, a thick brick wall, a sandwich panel, a double-leaf wall with poro-elastic material in the cavity, and a double glazing. The predictions are compared with experimental data and with results obtained using alternative prediction methods such as the transfer matrix method with spatial windowing, the hybrid wave based-transfer matrix method, and the hybrid finite element-statistical energy analysis method. These comparisons confirm the prediction accuracy of the proposed method and the computational efficiency against the conventional hybrid finite element-statistical energy analysis method.

  5. Housing markets and housing policies in India

    OpenAIRE

    Tiwari, Piyush; Rao, Jyoti

    2016-01-01

    Issues of housing in India are synonymous with ignorance of housing in active government involvement at the policy and program formulation levels. They are also due to the problems that unplanned urbanization, income disparity, poverty, illiteracy, and unemployment brought. These issues extenuated the housing problem, causing a housing shortage of 51 million in 2011. Though India has a long history of establishing policies, programs, and institutions to cater to housing, without allocating ad...

  6. Improving the efficiency of microwave devices with a double output cavity

    International Nuclear Information System (INIS)

    Eppley, K.R.; Herrmannsfeldt, W.B.; Lee, T.G.

    1986-05-01

    Double output cavities have been used experimentally to increase the efficiency of high-power klystrons. We have used particle-in-cell simulations with the 2 + 1/2 dimensional code MASK to optimize the design of double output cavities for the lasertron and the 50 MW klystron under development at SLAC. We discuss design considerations for double output cavities (e.g., optimum choice of voltages and phases, efficiency, wall interception, breakdown). We describe how one calculates the cavity impedance matrix from the gap voltages and phases. Simulation results are compared to experience with the 150 MW klystron

  7. 24 CFR 982.608 - Congregate housing: Voucher housing assistance payment.

    Science.gov (United States)

    2010-04-01

    ... Housing Types Congregate Housing § 982.608 Congregate housing: Voucher housing assistance payment. (a... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Congregate housing: Voucher housing assistance payment. 982.608 Section 982.608 Housing and Urban Development Regulations Relating to Housing and...

  8. Cell Wall Composition, Biosynthesis and Remodeling during Pollen Tube Growth

    Directory of Open Access Journals (Sweden)

    Jean-Claude Mollet

    2013-03-01

    Full Text Available The pollen tube is a fast tip-growing cell carrying the two sperm cells to the ovule allowing the double fertilization process and seed setting. To succeed in this process, the spatial and temporal controls of pollen tube growth within the female organ are critical. It requires a massive cell wall deposition to promote fast pollen tube elongation and a tight control of the cell wall remodeling to modify the mechanical properties. In addition, during its journey, the pollen tube interacts with the pistil, which plays key roles in pollen tube nutrition, guidance and in the rejection of the self-incompatible pollen. This review focuses on our current knowledge in the biochemistry and localization of the main cell wall polymers including pectin, hemicellulose, cellulose and callose from several pollen tube species. Moreover, based on transcriptomic data and functional genomic studies, the possible enzymes involved in the cell wall remodeling during pollen tube growth and their impact on the cell wall mechanics are also described. Finally, mutant analyses have permitted to gain insight in the function of several genes involved in the pollen tube cell wall biosynthesis and their roles in pollen tube growth are further discussed.

  9. Copper alloy conducting first wall for the FED-A tokamak

    International Nuclear Information System (INIS)

    Wiffen, F.W.

    1984-01-01

    The first wall of the tokamak FED-A device was designed to satisfy two conflicting requirements. They are a low electrical resistance to give a long eddy-current decay time and a high neutron transparency to give a favorable tritium breeding ratio. The tradeoff between these conflicting requirements resulted in a copper alloy first wall that satisfied the specific goals for FED-A, i.e., a minimum eddy-current decay time of 0.5 sec and a tritium breeding ratio of at least 1.2. Aluminum alloys come close to meeting the requirements and would also probably work. Stainless steel will not work in this application because shells thin enough to satisfy temperature and stress limits are not thick enough to give a long eddy-current decay time and to avoid disruption induced melting. The baseline first wall design is a rib-stiffened, double-wall construction. The total wall thickness is 1.5 cm, including a water coolant thickness of 0.5 cm. The first wall is divided into twelve 30-degree sectors. Flange rings at the ends of each sector are bolted together to form the torus. Structural support is provided at the top center of each sector

  10. Advanced method of double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Vlasov, P.V.; Yakimenko, V.F.

    1981-01-01

    An advanced method of double contrast examination of the stomach with the use of high concentrated barium suspension is described. It is shown that concentration of barium suspension must be not less than 200 mass/volume per cent to obtain the sharp image of the mucosal microrelief 6 standard position are recommended for the double contrast examination of all stomach walls. 200 patients with different digestive system diseases are examined with the help of developed methods. The sharp image of the mucosal microrelief is obtained in 70% cases [ru

  11. Analytic modeling of the feedback stabilization of resistive wall modes

    International Nuclear Information System (INIS)

    Pustovitov, Vladimir D.

    2003-01-01

    Feedback suppression of resistive wall modes (RWM) is studied analytically using a model based on a standard cylindrical approximation. Optimal choice of the input signal for the feedback, effects related to the geometry of the feedback active coils, RWM suppression in a configuration with ITER-like double wall, are considered here. The widespread opinion that the feedback with poloidal sensors is better than that with radial sensors is discussed. It is shown that for an ideal feedback system the best input signal would be a combination of radial and poloidal perturbations measured inside the vessel. (author)

  12. A Comparative Study of the Traditional Houses Kaili and Bugis-Makassar in Indonesia

    Science.gov (United States)

    Suharto, M. F.; Kawet, R. S. S. I.; Tumanduk, M. S. S. S.

    2018-02-01

    In this study, I compared the physical elements of two Indonesian traditional houses between a Kaili tribe (Central Sulawesi) and a Bugis-Makassar tribe (South Sulawesi). If we viewed of the name, meaning and function from both traditional houses have similarities, namely the Souraja/Saoraja house (House of the King), however, observed more detail the physical elements of architecture also show the differences. The spatial, physical and stylistic systems (N. John Habraken’s theory) were applied to analyze their differences and the similarities of the physical elements of architecture on those two traditional houses. The results of the analysis identified that the physical elements of architecture such as the orientation, the function and distribution of rooms (the spatial system), the constructions and materials of floor, wall and roof (the physical system) and the opening types of the door and window as well as ornaments used showed similarities. Meanwhile the physical elements of architecture such as the arrangement of columns, form and spatial pattern as well as the placement of the stairs (the spatial system), the constructions and materials of foundation, column and beam (the physical system) as well as the form of the roof and façade found differences of both traditional houses.

  13. Continuously renewed wall for a thermonuclear reactor

    International Nuclear Information System (INIS)

    Livshits, A.I.; Pustovojt, YU.M.; Samartsev, A.A.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii)

    1982-01-01

    The possibility of creating a continuously renewed first wall of a thermonuclear reactor is experimentally investigated. The following variants of the wall are considered: the wall is double, its part turned to plasma is made of comparatively thin material. The external part separated from it by a small gap appears to be protected from interaction with plasma and performs structural functions. The gap contains the mixture of light helium and hydrogen and carbon-containing gas. The light gas transfers heat from internal part of the wall to the external part. Carbon-containing gas provides continuous renewal of carbon coating of the operating surface. The experiment is performed with palladium membrane 20 μm thick. Carbon is introduced into the membrane by benzol pyrolysis on one of the surfaces at the membrane temperature of 900 K. Carbon removal from the operating side of the wall due to its spraying by fast particles is modelled by chemical itching with oxygen given to the operating membrane wall. Observation of the carbon release on the operating surface is performed mass-spectrometrically according to the observation over O 2 transformation into CO and CO 2 . It is shown that in cases of benzol pressure of 5x10 -7 torr, carbon current on the opposite surface is not less than 3x10 12 atoms/sm 2 s and corresponds to the expected wall spraying rate in CF thermonuclear reactors. It is also shown that under definite conditions the formation and maintaining of a through protective carbon coating in the form of a monolayer or volumetric phase is possible

  14. Designs of contraction nozzle and concave back-wall for IFMIF target

    Energy Technology Data Exchange (ETDEWEB)

    Ida, Mizuho E-mail: ida@ifmif.tokai.jaeri.go.jp; Nakamura, Hideo; Nakamura, Hiroo; Takeuchi, Hiroshi

    2004-02-01

    For the liquid lithium flow target of International Fusion Materials Irradiation Facility (IFMIF), the double reducer (two-step contraction) nozzle with a high-contraction ratio of 10 which generated high-speed uniform jet flows up to 20 m/s was proposed. Multi-dimensional hydraulic analyses were carried out to verify the performance of the proposed nozzle. The analytical results showed that the double reducer nozzle would well generate high-speed uniform flow, while one-step contraction nozzle generated non-uniform flow and resulted in flow thickening at the beam footprint. For the target design, the range of the concave back-wall radius with no lithium boiling due to the centrifugal force and proper component arrangement in the irradiation test cell was determined by the thermal-hydraulic analysis of a free-surface flow. It was verified that the back-wall radius from 0.25 to 10 m was acceptable in the velocity range of 10-20 m/s.

  15. Designs of contraction nozzle and concave back-wall for IFMIF target

    International Nuclear Information System (INIS)

    Ida, Mizuho; Nakamura, Hideo; Nakamura, Hiroo; Takeuchi, Hiroshi

    2004-01-01

    For the liquid lithium flow target of International Fusion Materials Irradiation Facility (IFMIF), the double reducer (two-step contraction) nozzle with a high-contraction ratio of 10 which generated high-speed uniform jet flows up to 20 m/s was proposed. Multi-dimensional hydraulic analyses were carried out to verify the performance of the proposed nozzle. The analytical results showed that the double reducer nozzle would well generate high-speed uniform flow, while one-step contraction nozzle generated non-uniform flow and resulted in flow thickening at the beam footprint. For the target design, the range of the concave back-wall radius with no lithium boiling due to the centrifugal force and proper component arrangement in the irradiation test cell was determined by the thermal-hydraulic analysis of a free-surface flow. It was verified that the back-wall radius from 0.25 to 10 m was acceptable in the velocity range of 10-20 m/s

  16. An experimental investigation for external RC shear wall applications

    Science.gov (United States)

    Kaltakci, M. Y.; Ozturk, M.; Arslan, M. H.

    2010-09-01

    The strength and rigidity of most reinforced concrete (RC) buildings in Turkey, which are frequently hit by destructive earthquakes, is not at a sufficient level. Therefore, the result of earthquakes is a significant loss of life and property. The strengthening method most commonly preferred for these type of RC buildings is the application of RC infilled walls (shear walls) in the frame openings of the building. However, since the whole building has to be emptied and additional heavy costs arise during this type of strengthening, users prefer not to strengthen their buildings despite the heavy risk they are exposed to. Therefore, it is necessary to develop easier-to-apply and more effective methods for the rapid strengthening of housing and the heavily-used public buildings which cannot be emptied during the strengthening process (such as hospitals and schools). This study empirically analyses the different methods of a new system which can meet this need. In this new system, named "external shear wall application", RC shear walls are applied on the external surface of the building, along the frame plane rather than in the building. To this end, 7 test samples in 1/2 and 1/3 geometrical scale were designed to analyse the efficiency of the strengthening technique where the shear wall leans on the frame from outside of the building (external shear wall application) and of the strengthening technique where a specific space is left between the frame and the external shear wall by using a coupling beam to connect elements (application of external shear wall with coupling beam). Test results showed that the maximum lateral load capacity, initial rigidity and energy dissipation behaviours of the samples strengthened with external shear wall were much better than those of the bare frames.

  17. An experimental investigation for external RC shear wall applications

    Directory of Open Access Journals (Sweden)

    M. Y. Kaltakci

    2010-09-01

    Full Text Available The strength and rigidity of most reinforced concrete (RC buildings in Turkey, which are frequently hit by destructive earthquakes, is not at a sufficient level. Therefore, the result of earthquakes is a significant loss of life and property. The strengthening method most commonly preferred for these type of RC buildings is the application of RC infilled walls (shear walls in the frame openings of the building. However, since the whole building has to be emptied and additional heavy costs arise during this type of strengthening, users prefer not to strengthen their buildings despite the heavy risk they are exposed to. Therefore, it is necessary to develop easier-to-apply and more effective methods for the rapid strengthening of housing and the heavily-used public buildings which cannot be emptied during the strengthening process (such as hospitals and schools. This study empirically analyses the different methods of a new system which can meet this need. In this new system, named "external shear wall application", RC shear walls are applied on the external surface of the building, along the frame plane rather than in the building. To this end, 7 test samples in 1/2 and 1/3 geometrical scale were designed to analyse the efficiency of the strengthening technique where the shear wall leans on the frame from outside of the building (external shear wall application and of the strengthening technique where a specific space is left between the frame and the external shear wall by using a coupling beam to connect elements (application of external shear wall with coupling beam. Test results showed that the maximum lateral load capacity, initial rigidity and energy dissipation behaviours of the samples strengthened with external shear wall were much better than those of the bare frames.

  18. On sound transmission through double-walled cylindrical shells lined with poroelastic material: Comparison with Zhou's results and further effect of external mean flow

    Science.gov (United States)

    Liu, Yu; He, Chuanbo

    2015-12-01

    In this discussion, the corrections to the errors found in the derivations and the numerical code of a recent analytical study (Zhou et al. Journal of Sound and Vibration 333 (7) (2014) 1972-1990) on sound transmission through double-walled cylindrical shells lined with poroelastic material are presented and discussed, as well as the further effect of the external mean flow on the transmission loss. After applying the corrections, the locations of the characteristic frequencies of thin shells remain unchanged, as well as the TL results above the ring frequency where BU and UU remain the best configurations in sound insulation performance. In the low-frequency region below the ring frequency, however, the corrections attenuate the TL amplitude significantly for BU and UU, and hence the BB configuration exhibits the best performance which is consistent with previous observations for flat sandwich panels.

  19. Housing and Health: The relationship between housing conditions ...

    African Journals Online (AJOL)

    okanlawon

    2011-10-22

    Oct 22, 2011 ... Housing and Health: The relationship between housing ... The authors in chapter one, deal extensively with historical context of housing and health chronologically ... Housing and Health: Time Again for Public Health Action.

  20. DOE ZERH Case Study: BPC Green Builders, Taft School, Watertown, CT

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the cold climate that got a HERS 33 without PV or HERS -14 with PV, with 8.5” double 2x4 walls with 8.5” (R-32) blown cellulose plus R-6 rigid foam, basement with 3” ccsf on interior plus 2x4 stud walls with R-13 blown cellulose, with R-20 around slab, R-38 under slab; a vented attic with R-100 blown cellulose; a central heat pump; HRV; heat pump water heater; 100% LED; and Passive House Institute U.S.+, LEED platinum, and Living Building Challenge certifications.

  1. The dorsal shell wall structure of Mesozoic ammonoids

    Directory of Open Access Journals (Sweden)

    Gregor Radtke

    2017-03-01

    Full Text Available The study of pristine preserved shells of Mesozoic Ammonoidea shows different types of construction and formation of the dorsal shell wall. We observe three major types: (i The vast majority of Ammonoidea, usually planispirally coiled, has a prismatic reduced dorsal shell wall which consists of an outer organic component (e.g., wrinkle layer, which is the first layer to be formed, and the subsequently formed dorsal inner prismatic layer. The dorsal mantle tissue suppresses the formation of the outer prismatic layer and nacreous layer. With the exception of the outer organic component, secretion of a shell wall is omitted at the aperture. A prismatic reduced dorsal shell wall is always secreted immediately after the hatching during early teleoconch formation. Due to its broad distribution in (planispiral Ammonoidea, the prismatic reduced dorsal shell wall is probably the general state. (ii Some planispirally coiled Ammonoidea have a nacreous reduced dorsal shell wall which consists of three mineralized layers: two prismatic layers (primary and secondary dorsal inner prismatic layer and an enclosed nacreous layer (secondary dorsal nacreous layer. The dorsal shell wall is omitted at the aperture and was secreted in the rear living chamber. Its layers are a continuation of an umbilical shell doubling (reinforcement by additional shell layers that extends towards the ventral crest of the preceding whorl. The nacreous reduced dorsal shell wall is formed in the process of ontogeny following a prismatic reduced dorsal shell wall. (iii Heteromorph and some planispirally coiled taxa secrete a complete dorsal shell wall which forms a continuation of the ventral and lateral shell layers. It is formed during ontogeny following a prismatic reduced dorsal shell wall or a priori. The construction is identical with the ventral and lateral shell wall, including a dorsal nacreous layer. The wide distribution of the ability to form dorsal nacre indicates that it is

  2. Transitional Flow in an Arteriovenous Fistula: Effect of Wall Distensibility

    Science.gov (United States)

    McGah, Patrick; Leotta, Daniel; Beach, Kirk; Aliseda, Alberto

    2012-11-01

    Arteriovenous fistulae are created surgically to provide adequate access for dialysis in patients with end-stage renal disease. Transitional flow and the subsequent pressure and shear stress fluctuations are thought to be causative in the fistula failure. Since 50% of fistulae require surgical intervention before year one, understanding the altered hemodynamic stresses is an important step toward improving clinical outcomes. We perform numerical simulations of a patient-specific model of a functioning fistula reconstructed from 3D ultrasound scans. Rigid wall simulations and fluid-structure interaction simulations using an in-house finite element solver for the wall deformations were performed and compared. In both the rigid and distensible wall cases, transitional flow is computed in fistula as evidenced by aperiodic high frequency velocity and pressure fluctuations. The spectrum of the fluctuations is much more narrow-banded in the distensible case, however, suggesting a partial stabilizing effect by the vessel elasticity. As a result, the distensible wall simulations predict shear stresses that are systematically 10-30% lower than the rigid cases. We propose a possible mechanism for stabilization involving the phase lag in the fluid work needed to deform the vessel wall. Support from an NIDDK R21 - DK08-1823.

  3. City of Ljubljana: Its housing, population and housing conditions

    Directory of Open Access Journals (Sweden)

    Maša Filipovič

    2007-01-01

    Full Text Available The article gives an overview of key aspect of housing in Municipality of Ljubljana. The characteristics of households, of housing and their relation influence the housing situation in the city. Characteristic of housing refer mainly to quality of the dwellings, affordability and correspondence to the wishes of the inhabitants. The second important dimensions are households and their characteristics. In Europe and Slovenia increase in number of household can be observed, which in turn are becoming smaller. The housing policy has a role in establishing a balance between households and housing, i.e. ensuring that housing corresponds to the needs of individual households and to their number. For achieving this, knowledge and appropriate data are of vital importance. In the article we present the results of the Housing survey 2005. We observe housing conditions in a comparative perspective (Ljubljana in comparison to Maribor, Slovenia and selected European cities and according to three dimensions: housing fund, households and housing conditions.

  4. The role of ventilation in controlling the dispersion of radon gas from a cellar in a domestic house

    International Nuclear Information System (INIS)

    Ward, I.C.; Wang, F.; Sharples, S.; Pitts, A.C.

    1994-01-01

    In certain parts of the United Kingdom where radon gas seeps from the ground into the basement of domestic housing, normal methods of removing this gas by using under floor extract ventilation is not appropriate. In this situation the radon gas enters the basement through the side walls of the cellar and hence into the house. Using mechanical ventilation to either pressurise or de-pressurise the cellar may be an appropriate solution to this problem, however, before installing such a system in a house a ventilation strategy must be established. This paper sets out a ventilation strategy for minimising the ingress of radon into a domestic house, which has been established by simulating the air movement within a domestic house using Breeze Version 6 for a range of environmental conditions. The results of this analysis show that in winter when the emission of radon gas is most strong de-pressurisation of the basement can improve the ingress of the gas to the rest of the house. (author)

  5. Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography-a phantom study

    International Nuclear Information System (INIS)

    Yamada, Minoru; Jinzaki, Masahiro; Tanami, Yutaka; Matsumoto, Kazuhiro; Ueno, Akihisa; Kuribayashi, Sachio; Nukui, Masatake; Imai, Yasuhiro; Ishihara, Yotaro; Nishide, Akihiko; Sasaki, Kosuke

    2011-01-01

    The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

  6. Energy house - dream house

    Energy Technology Data Exchange (ETDEWEB)

    1981-07-01

    An energy house a prefabricated house with an extensive minimization of heat losses, is air-conditioned by means of a combined heating system consisting of hot water cycle and recirculating heating. The energy system is trivalent: wind power, solar energy with heat pumps and normal oil heating.

  7. Structure reconstruction of TiO2-based multi-wall nanotubes: first-principles calculations.

    Science.gov (United States)

    Bandura, A V; Evarestov, R A; Lukyanov, S I

    2014-07-28

    A new method of theoretical modelling of polyhedral single-walled nanotubes based on the consolidation of walls in the rolled-up multi-walled nanotubes is proposed. Molecular mechanics and ab initio quantum mechanics methods are applied to investigate the merging of walls in nanotubes constructed from the different phases of titania. The combination of two methods allows us to simulate the structures which are difficult to find only by ab initio calculations. For nanotube folding we have used (1) the 3-plane fluorite TiO2 layer; (2) the anatase (101) 6-plane layer; (3) the rutile (110) 6-plane layer; and (4) the 6-plane layer with lepidocrocite morphology. The symmetry of the resulting single-walled nanotubes is significantly lower than the symmetry of initial coaxial cylindrical double- or triple-walled nanotubes. These merged nanotubes acquire higher stability in comparison with the initial multi-walled nanotubes. The wall thickness of the merged nanotubes exceeds 1 nm and approaches the corresponding parameter of the experimental patterns. The present investigation demonstrates that the merged nanotubes can integrate the two different crystalline phases in one and the same wall structure.

  8. Comparative Study on the Cost of Building Public House Construction Using Red Brick and Interlock Brick Building Material in the City of Banda Aceh

    Science.gov (United States)

    Malahayati, Nurul; Hayati, Yulia; Nursaniah, Cut; Firsa, T.; Fachrurrazi; Munandar, Aris

    2018-05-01

    Red brick and interlocking brick are the building materials that are often used for wall installation work on houses construction. In the development of building materials technology and cost savings, interlocking brick can be alternative to replace red bricks. In Aceh Province, the use of interlocking bricks is less popular compared to other big cities in Indonesia. Interlocking brick is made from a mixture of clay, concrete sand and compacted cement and one of the environmentally friendly materials because it does not burn the process like red brick material. It is named interlocking brick because the installation method is locked together and it serves as a structural and partition wall of residential buildings. The aims of this study are to compare the cost of building a house in Banda Aceh City using red brick and interlock brick building materials. The data were obtained from interviews and questionnaires distributed to respondents who had built houses in Banda Aceh City. The results concluded that the house construction cost using interlock brick offer lower construction cost at comparable quality rather than using red brick.

  9. Double jeopardy: assessing the association between internal displacement, housing quality and chronic illness in a low-income neighborhood.

    Science.gov (United States)

    Habib, Rima R; Yassin, Nasser; Ghanawi, Joly; Haddad, Pascale; Mahfoud, Ziyad

    2011-04-01

    PURPOSE: This study analyzed associations between war-related internal displacement, housing quality and the prevalence of chronic illness in Nabaa, a low-income neighborhood on the outskirts of Beirut, Lebanon. METHODS: A cross-sectional survey of sociodemographics, household characteristics and health conditions of the study population was carried out in 2002. Using a structured questionnaire, the research team surveyed 1,151 households representing 4,987 residents of all ages. The survey was administered to a proxy respondent from each household in face-to-face interviews. A multiple logistic regression model using the generalized estimation equation method was constructed to assess the simultaneous effect of displacement and housing quality on reported ill health, while adjusting for potential confounders. RESULTS: Housing quality and internal displacement were strongly associated with occurrences of chronic illness. The most vulnerable respondents were older residents, females and internally displaced people, who reported high rates of chronic illnesses. Residents with high levels of education were less likely to report a chronic illness than those that had elementary education or less. CONCLUSION: Nabaa residents' experience of poor health was associated with inadequate housing quality. Moreover, residents who have been displaced experience worse living conditions and were more likely to experience poor health than those who were not displaced. These results reveal a need for policies to improve housing quality and alleviate war-related consequences in low-income neighborhoods.

  10. Engineering Assessment of Big House at Summit Station, Greenland

    Science.gov (United States)

    2011-04-01

    exterior consisted of 127-mm structural insulated panels (SIP), with 12.7- mm stressed oriented strand board ( OSB ) skins (CPS 2009b; Tobiasson unpublished...Penetrations Common\\construction\\Big House Penetrations.txt 2009 November 17th Tuesday Walls are 8 in. thick: 5 in. SIP (1/2 in. OSB + 4 in...yellow open cella + 0.5 in. OSB + metal cladding) + 1.5 in. closed(?) cell foamb + 0.5 in. T-1-11. Roof is 9 in. thick: 5 in. SIP + ~3.5 in. foam + 1

  11. Building a sustainable future: Bioclimatic house

    Science.gov (United States)

    Gomez Mallen, Esther; Rivera Fusalba, Oriol

    2010-05-01

    The application of bioclimatic principles is a critical factor in reducing energy consumption and CO2 emissions. This poster develops a sequence of experiments and building working models in order to form students of secondary school and make progress towards real applications of new energy technologies. The activity has been carried out by 14 and 15-year-old students using a Power House building kit. Scientific method and Information and Communication Technologies (ICT) were used as an effective system of acquiring new knowledge. Students were asked to form cooperative groups. Firstly, each group had to choose the best location and orientation in the imaginary Dragon Island for the construction of the house. The house consisted of eight Styrofoam parts and one transparent plastic part. The Styrofoam parts formed the house structure (floor, walls and roof) with two interior chambers and the attached greenhouse. Once the house was assembled in a few steps, it was ready for the students to start adding more components. Students then conducted several experiments related to the heat and light energy of the Sun and the energy of the wind. Some of the experiments and building projects realized were: how to capture the Sun to heat the house by passive solar heating, how to collect the Sun's rays to heat water using a Sun Collector and how to extract electricity current from Sun Power station and from wind power plant. For most of the assays it was necessary to record the temperature and students used for that purpose a temperature sensor that comes with Multilog Pro, a portable, graphic data collection and analysis system. Groups of students were really engaged in the project and each of them ran a different test with the house. Finally they proved if their initial hypothesis was correct and they had to expose the results to the rest of the class members. Students demonstrated how we can transform and use renewable forms of energy. With the experiments students

  12. Polarisation observables F and T in double π{sup 0} photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Garni, Stefanie [Departement of Physics, University of Basel, CH-4056 Basel (Switzerland); Collaboration: A2-Collaboration

    2013-07-01

    The measurement of single and double polarization observables gives information about the different resonance contributions to the cross section and hence leads to a better understanding of the nucleon and it's excited states. Double π{sup 0} photo-production is a very interesting reaction for the investigation of nuclear resonances. Photo-production of pion pairs allows to study states which decay preferentially via intermediate resonances. The double neutral channel has the additional advantage of only small non-resonant background contributions. Double π{sup 0}-photo-production off a transversally polarized H-butanol target has been measured using circularly polarized bremsstrahlung photons produced by MAMI-C with incident energies up to 1.5 GeV. The double π{sup 0} reaction was identified using a combined setup of the Crystal Ball colorimeter and a TAPS forward wall which results in an almost 4π acceptance. Preliminary results on the single polarization observable T and double polarization observable F are presented.

  13. Arabidopsis leucine-rich repeat extensin (LRX) proteins modify cell wall composition and influence plant growth.

    Science.gov (United States)

    Draeger, Christian; Ndinyanka Fabrice, Tohnyui; Gineau, Emilie; Mouille, Grégory; Kuhn, Benjamin M; Moller, Isabel; Abdou, Marie-Therese; Frey, Beat; Pauly, Markus; Bacic, Antony; Ringli, Christoph

    2015-06-24

    Leucine-rich repeat extensins (LRXs) are extracellular proteins consisting of an N-terminal leucine-rich repeat (LRR) domain and a C-terminal extensin domain containing the typical features of this class of structural hydroxyproline-rich glycoproteins (HRGPs). The LRR domain is likely to bind an interaction partner, whereas the extensin domain has an anchoring function to insolubilize the protein in the cell wall. Based on the analysis of the root hair-expressed LRX1 and LRX2 of Arabidopsis thaliana, LRX proteins are important for cell wall development. The importance of LRX proteins in non-root hair cells and on the structural changes induced by mutations in LRX genes remains elusive. The LRX gene family of Arabidopsis consists of eleven members, of which LRX3, LRX4, and LRX5 are expressed in aerial organs, such as leaves and stem. The importance of these LRX genes for plant development and particularly cell wall formation was investigated. Synergistic effects of mutations with gradually more severe growth retardation phenotypes in double and triple mutants suggest a similar function of the three genes. Analysis of cell wall composition revealed a number of changes to cell wall polysaccharides in the mutants. LRX3, LRX4, and LRX5, and most likely LRX proteins in general, are important for cell wall development. Due to the complexity of changes in cell wall structures in the lrx mutants, the exact function of LRX proteins remains to be determined. The increasingly strong growth-defect phenotypes in double and triple mutants suggests that the LRX proteins have similar functions and that they are important for proper plant development.

  14. External wall structure of green rural houses in Daqing, China, based on life cycle and ecological footprint theories

    Directory of Open Access Journals (Sweden)

    Hong Jin

    2015-09-01

    Full Text Available Daqing is situated in one of the severely cold regions of China. The living environment in this region is extremely poor because of the harsh climate and the backward economy. The external wall is an important component of the external envelope of buildings, and it greatly contributes to the indoor thermal environment. By taking the external wall as the research object, this study summarizes the characteristics of the external wall structure and analyzes the common materials used in existing rural residences. Specifically, we combine life cycle theory and ecological footprint (EF theory and introduce the green external wall structure, as well as its application in practice, in accordance with the local ecosystem. Results show that anecological residence offers a better environment and greater economic benefits than a traditional residence. The annual energy consumption, CO2 consumption, and EF of the ecological residence in this study are lower than those of the traditional residence by 69.61%, 17.5 t, and 99.47%, respectively.

  15. Effects of Geofoam Panels on Static Behavior of Cantilever Retaining Wall

    Directory of Open Access Journals (Sweden)

    Navid Hasanpouri Notash

    2018-01-01

    Full Text Available Geofoam is one of the geosynthetic products that can be used in geotechnical applications. According to researches, expanded polystyrene (EPS geofoam placed directly against a rigid retaining wall has been proposed as a strategy to reduce static loads on the wall. This study employed a finite difference analysis using a 2-D FLAC computer program by considering yielding and nonyielding states for retaining walls to explore the effectiveness of geofoam panels in improving the static performance of cantilever retaining walls. Retaining walls at heights of 3, 6, and 9 meters and geofoam panels with densities of 15, 20, and 25 (kg/m3 at three relative thicknesses of t/H = 0.05, 0.2, and 0.4 were modelled in this numerical study. In addition, the performance of the double EPS buffer system, which involves two vertical geofoam panels, in retaining walls’ stability with four panel spacing (50, 100, 150, and 200 cm was also evaluated in this research. The results showed that use of EPS15 with density equal to 15 (kg/m3 which has the lowest density among other geofoam panels has a significant role in reduction of lateral stresses, although the performance of geofoam in nonyielding retaining walls is better than yielding retaining walls.

  16. Ameliorating Local Impacts with Architectural Research: Subprime Mortgages & Housing Quality

    Directory of Open Access Journals (Sweden)

    Lynne M. Dearborn

    2012-10-01

    Full Text Available Shock waves from the current housing crisis that still echo through Wall Street’s largest financial firms, not only have threatened to topple financial markets and drive the country into a depression, but have also undermined the all-time high home ownership rate in the United States. The most attention-grabbing dimensions and headlines of the current crisis seem to be the staggering losses incurred by the likes of Bear Sterns and Citigroup, and the demise of some of the large corporations such as Washington Mutual. However, the real crisis is not on Wall Street or in the banking sector, but in low- and moderate-income and minority homes and neighborhoods throughout the country. At least ten years before the present subprime foreclosure crisis became mainstream news, these marginalized communities were feeling the negative effects of mortgage fraud and predatory lending practices occurring with regularity in the subprime market. This paper discusses an ongoing study of Subprime Lending, Mortgage Fraud and Housing Quality in process since 2002. This four-part study has employed foreclosure data with statistical and mapping analysis, detailed interviews with victims of predatory lending, systematic documentation of the resulting housing environments, and documentation of property improvements in light of victims’ legal settlements. While subprime lending has supported the expansion of homeownership in the United States, this on-going study suggests that this expansion has sometimes been at the expense of safe, code-compliant living environments forlow-income, minority and elderly homeowners. Some of the victims of predatory lending and mortgage fraud have sought legal redress through the courts but many have suffered personal financial, health, emotional, and family crises as well. The current broad-scale discussion of the topic has given attention to the lack of regulation facilitating these unethical practices, but it is unclear that current

  17. Energy Performance of a Light Wood-Timber Structured House in the Severely Cold Region of China

    Directory of Open Access Journals (Sweden)

    Meng Zhen

    2018-05-01

    Full Text Available The purpose of the study was to determine the energy performance of a timber structured house built in Harbin, a severely cold region of China. The research team conducted a field test on the house that lasted three months (15 January–15 April 2008. The test included the winter heating energy consumption, average indoor temperature and relative humidity, building heat storage capacity, heat transfer coefficient of the wall, total air volume of air-conditioning system, etc. The test results showed that the total heating was calculated to be 73,240.59 MJ in winter. Thermal imaging tests were carried out on the house and found no obvious thermal defects such as thermal bridges. In conclusion, the timber structured house has a good level of building energy conservation and would provide a good exemplary for green building design and construction in similar severely cold regions in the world.

  18. Costs and outcomes of improving population health through better social housing: a cohort study and economic analysis.

    Science.gov (United States)

    Bray, Nathan; Burns, Paul; Jones, Alice; Winrow, Eira; Edwards, Rhiannon Tudor

    2017-12-01

    We sought to determine the impact of warmth-related housing improvements on the health, well-being, and quality of life of families living in social housing. An historical cohort study design was used. Households were recruited by Gentoo, a social housing contractor in North East England. Recruited households were asked to complete a quality of life, well-being, and health service use questionnaire before receiving housing improvements (new energy-efficient boiler and double-glazing) and again 12 months afterwards. Data were collected from 228 households. The average intervention cost was £3725. At 12-month post-intervention, a 16% reduction (-£94.79) in household 6-month health service use was found. Statistically significant positive improvements were observed in main tenant and household health status (p cost-effective means of improving the health of social housing tenants and reducing health service expenditure, particularly in older populations.

  19. Active particle control experiments and critical particle flux discriminating between the wall pumping and fuelling in the compact plasma wall interaction device CPD spherical tokamak

    International Nuclear Information System (INIS)

    Zushi, H.; Sakamoto, M.; Yoshinaga, T.; Higashizono, Y.; Hanada, K.; Yoshida, N.; Tokunaga, K.; Kawasaki, S.; Sato, K. N.; Nakamura, K.; Idei, H.; Hirooka, Y.; Bhattacharyay, R.; Okamoto, K.; Miyazaki, T.; Honma, H.; Nakashima, Y.; Nishino, N.; Kado, S.; Shikama, T.

    2009-01-01

    Two approaches associated with wall recycling have been performed in a small spherical tokamak device CPD (compact plasma wall interaction experimental device), that is, (1) demonstration of active particle recycling control, namely, 'active wall pumping' using a rotating poloidal limiter whose surface is continuously gettered by lithium and (2) a basic study of the key parameters which discriminates between 'wall pumping and fuelling'. For the former, active control of 'wall pumping' has been demonstrated during 50 kW RF current drive discharges whose pulse length is typically ∼300 ms. Although the rotating limiter is located at the outer board, as soon as the rotating drum is gettered with lithium, hydrogen recycling measured with H α spectroscopy decreases by about a factor of 3 not only near the limiter but also in the centre stack region. Also, the oxygen impurity level measured with O II spectroscopy is reduced by about a factor of 3. As a consequence of the reduced recycling and impurity level, RF driven current has nearly doubled at the same vertical magnetic field. For the latter, global plasma wall interaction with plasma facing components in the vessel is studied in a simple torus produced by electron cyclotron waves with I p -4 to ∼0.1 x 10 -4 Torr during the experimental campaign (∼3000 shots). In the wall pumping pressure range the wall pumping fraction is reduced with increasing surface temperature up to 150 deg. C.

  20. Validation of double-spike electrograms as markers of conduction delay or block in atrial flutter.

    Science.gov (United States)

    Cosio, F G; Arribas, F; Barbero, J M; Kallmeyer, C; Goicolea, A

    1988-04-01

    Recent mapping studies of atrial flutter have shown that fragmented electrograms can be found in most cases from the posterior, posteroseptal and posterolateral walls of the right atrium. The fragmentation pattern most often consists of a double spike. To further assess double-spike electrograms as a possible marker of conduction delay, bipolar electrograms were continuously recorded during atrial overdrive pacing of common flutter from the right atrium (7 patients) and from the proximal coronary sinus (5). Baseline double-spike separation of 50 to 130 ms was unchanged in 1 patient and slightly increased (5 to 25 ms) in 4 by coronary sinus pacing. The electrogram sequence was unchanged and the surface morphology was similar to that of basal flutter. Right atrial pacing decreased double-spike separation by 25 to 85 ms from basal values of 45 to 175 ms (23 to 83%), suggesting fusion in the area of fragmented electrograms. These findings suggest that double-spike electrograms represent activation on both sides of a conduction delay zone. The changes induced in these electrograms by pacing from the anterior right atrium and the coronary sinus are consistent with flutter circuits rotating counterclockwise (frontal plane) in the posterior right atrial wall in common atrial flutter.

  1. DOE ZERH Case Study: TC Legend Homes, Bellingham Power House, Bellingham, WA

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got HERS 34 without PV or HERS -12 with PV, with 6” SIP walls and 10” SIP roof; R-28 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED.

  2. The adsorption effect of C6H5 on density of states for double wall carbon nanotubes by tight binding model

    International Nuclear Information System (INIS)

    Fathalian, A.

    2012-01-01

    A theoretical approach based on a tight-binding model is developed to study the effects of the adsorption of finite concentrations of C 6 H 5 gas molecules on double-walled carbon nanotube (DWCNT) electronic properties. To obtain proper hopping integrals and random on-site energies for the case of one molecule adsorption, the local density of states for various hopping integrals and random on-site energies are calculated. Since C 6 H 5 molecule is a donor with respect to the carbon nanotubes and their states should appear near the conduction band of the system, effects of various hopping integral deviations and on-site energies for one molecule adsorption are considered to find proper hopping and on-site energies consistent with expected n-type semiconductor. We found that adsorption of C 6 H 5 gas molecules could lead to a (8.0)-(20.0) DWCNT n-type semiconductor. The width of impurity adsorbed gas states in the density of states could be controlled by adsorbed gas concentration.

  3. Refined 2D and Exact 3D Shell Models for the Free Vibration Analysis of Single- and Double-Walled Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Salvatore Brischetto

    2015-12-01

    Full Text Available The present paper talks about the free vibration analysis of simply supported Single- and Double-Walled Carbon Nanotubes (SWCNTs and DWCNTs. Refined 2D Generalized Differential Quadrature (GDQ shell methods and an exact 3D shell model are compared. A continuum approach (based on an elastic three-dimensional shell model is used for natural frequency investigation of SWCNTs and DWCNTs. SWCNTs are defined as isotropic cylinders with an equivalent thickness and Young modulus. DWCNTs are defined as two concentric isotropic cylinders (with an equivalent thickness and Young modulus which can be linked by means of the interlaminar continuity conditions or by means of van der Waals interactions. Layer wise approaches are mandatory for the analysis of van der Waals forces in DWCNTs. The effect of van der Waals interaction between the two cylinders is shown for different DWCNT lengths, diameters and vibration modes. The accuracy of beam models and classical 2D shell models in the free vibration analysis of SWCNTs and DWCNTs is also investigated.

  4. Bubble jet impact on a rigid wall of different stand-off parameters

    International Nuclear Information System (INIS)

    Li, S; Wang, S P; Zhang, A M

    2015-01-01

    One of the key features of the dynamics of a bubble near a rigid wall is the development of a high liquid jet, generating highly localized pressure on the wall. In present study, the boundary integral method is employed to simulate this phenomenon, and the vortex ring model is introduced to handle the discontinued potential of the toroidal bubble. Meanwhile, the pressure induced in the whole process is calculated by an auxiliary function. The effect of the stand-off parameter on the bubble dynamics and the pressure on the wall is investigated, and a double-peaked structure occurs in the pressure profile after the jet impact in some cases, which is associated with the jet impact and the high internal pressure inside the bubble

  5. Sasol Coal`s `better brick` for colliery ventilation walls

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-01

    Sasol coal has developed a better brick for construction of ventilation walls underground. It has proven to be a speedy and cost-saving alternative to the standard concrete block used for the purpose. The brick has an interlocking design ensuring that it is laid correctly. Unlike the conventional concrete block, the ventilation walls built for the new brick do not have to be plastered to achieve airtightness. The skills required to build such walls are minimal as the design of the brick makes it virtually impossible to lay it badly or unevenly - further facilitated by the absence of mortar. While introducing the new method Sasol Coal took the opportunity to introduce a purpose-made trailer for transporting the bricks, with the trailer doubling as a building platform on site. This has further contributed to the efficiency and speed of the operation. It has also reduced to a minimum the number of times the bricks are handled, thus cutting down on breakages. 1 fig.

  6. 7 CFR 1944.664 - Housing preservation and replacement housing assistance.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Housing preservation and replacement housing...) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE (CONTINUED) PROGRAM REGULATIONS (CONTINUED) HOUSING Housing...

  7. Development of evaluation method on flow-induced vibration and corrosion of components in two-phase flow by coupled analysis. 5. Evaluation of wall thinning rate with the coupled model of static electrochemical analysis and dynamic double oxide layer analysis

    International Nuclear Information System (INIS)

    Uchida, Shunsuke; Naitoh, Masanori; Okada, Hidetoshi; Uehara, Yasushi

    2008-01-01

    Wall thinning rates due to FAC were calculated with the coupled model of static electrochemical analysis and dynamic double oxide layer analysis at the identified danger zone. Anodic and cathodic current densities and ECPs were calculated with the static electrochemistry model and ferrous ion release rate determined by the anodic current density was used as input for the dynamic double oxide layer model. Thickness of oxide film and its characteristics determined by the dynamic double oxide layer model were used for the electrochemistry model to determine the resistances of cathodic current from the bulk to the surface and anodic current from the surface to the bulk. Two models were coupled to determine local corrosion rate and ECP for various corrosive conditions. The calculated results of the coupled models had good agreement with the measured ones. (author)

  8. SIMS investigations of wall coatings for application in nuclear fusion reactors

    International Nuclear Information System (INIS)

    Friedbacher, G.; Virag, A.; Grasserbauer, M.; Esser, H.G.; Wienhold, P.

    1989-01-01

    Carbon coated metals have proven to be useful materials for limiters and the first wall in fusion reactors. In this paper SIMS investigations of a-C:B single coated and a-C:D/a-C:B double coated stainless steel samples, which have been exposed to TOKAMAK discharges in deuterium and helium, are described. (orig.)

  9. Understanding Housing Delays and Relocations Within the Housing First Model.

    Science.gov (United States)

    Zerger, Suzanne; Pridham, Katherine Francombe; Jeyaratnam, Jeyagobi; Hwang, Stephen W; O'Campo, Patricia; Kohli, Jaipreet; Stergiopoulos, Vicky

    2016-01-01

    This study explores factors contributing to delays and relocations during the implementation of the Housing First model in Toronto, Ontario. While interruptions in housing tenure are expected en route to recovery and housing stability, consumer and service provider views on finding and keeping housing remain largely unknown. In-person interviews and focus groups were conducted with 48 study participants, including 23 case managers or housing workers and 25 consumers. The following three factors contributed to housing delays and transfers: (1) the effectiveness of communication and collaboration among consumers and service providers, (2) consumer-driven preferences and ambivalence, and (3) provider prioritization of consumer choice over immediate housing access. Two strategies--targeted communications and consumer engagement in housing searches--supported the housing process. Several factors affect the timing and stability of housing. Communication between and among providers and consumers, and a shared understanding of consumer choice, can further support choice and recovery.

  10. Thermal Transmittance and the Embodied Energy of Timber Frame Lightweight Walls Insulated with Straw and Reed

    Science.gov (United States)

    Miljan, M.; Miljan, J.

    2015-11-01

    Sustainable energy use has become topical in the whole world. Energy gives us comfort we are used to. EU and national regulations determine energy efficiency of the buildings. This is one side of the problem - energy efficiency of houses during exploitation. But the other side is primary energy content of used materials and more rational use of resources during the whole life cycle of a building. The latter value constitutes about 8 - 20% from the whole energy content. Calculations of energy efficiency of materials lead us to energy efficiency of insulation materials and to comparison of natural and industrial materials taking into account their thermal conductivity as well as their primary energy content. Case study of the test house (built in 2012) insulated with straw bales gave the result that thermal transmittance of investigated straw bale walls was according to the minimum energy efficiency requirements set in Estonia U = 0.12 - 0.22 W/m2K (for walls).

  11. THE HOUSING SITUATION OF THE RURAL POPULATION IN THE SUSTAINABLE CONSUMPTION

    Directory of Open Access Journals (Sweden)

    Alicja Stolarska

    2015-09-01

    Full Text Available  The basic research material comprised empirical data on household budgets conducted by CSO (The Central Statistical Offi ce. The analysed housing conditions of 15 742 rural households in 2012 in Poland. Attention is paid to some households in poor housing situation. Diversity of housing situation and factors affecting this state of affairs is presented. We observe not only the diversity of household wealth, but there are also disparities in housing situation. Disturbing and contrary to the principles of sustainable development and sustainable consumption is the fact that there are signifi cant differences in the size (10–900 m2 and quality of fl ats. Some have more than one house, others are not able to meet their basic needs. Until 13% fl ats of rural households had leaky roofs, damp walls or rotting windows and fl oors. Nearly 1.3% of them also was too tight and located in an area with a low level of infrastructure. It was associated with poor revenue situation, but also the type of the main source of income, family situation and who was the owner of the apartment. Approx. 1.4% of the fl ats had no running water, and almost 18% were heated using heating furnaces, which are not only a nuisance in operation, but also emit carbon dioxide harmful to the environment. Some rural households (5% had credit, but they have better fi nancial situation than others.

  12. Housing management and maintenance practise of Dutch housing associations

    NARCIS (Netherlands)

    Straub, A.

    This paper summarises the state-of-the-art in housing management and maintenance practise of Dutch housing associations based on a survey conducted among almost all housing associations. We address the question what the current developments are in housing management and maintenance practice in the

  13. Preferential growth of short aligned, metallic-rich single-walled carbon nanotubes from perpendicular layered double hydroxide film.

    Science.gov (United States)

    Zhao, Meng-Qiang; Tian, Gui-Li; Zhang, Qiang; Huang, Jia-Qi; Nie, Jing-Qi; Wei, Fei

    2012-04-07

    Direct bulk growth of single-walled carbon nanotubes (SWCNTs) with required properties, such as diameter, length, and chirality, is the first step to realize their advanced applications in electrical and optical devices, transparent conductive films, and high-performance field-effect transistors. Preferential growth of short aligned, metallic-rich SWCNTs is a great challenge to the carbon nanotube community. We report the bulk preferential growth of short aligned SWCNTs from perpendicular Mo-containing FeMgAl layered double hydroxide (LDH) film by a facile thermal chemical vapor deposition with CH(4) as carbon source. The growth of the short aligned SWCNTs showed a decreased growth velocity with an initial value of 1.9 nm s(-1). Such a low growth velocity made it possible to get aligned SWCNTs shorter than 1 μm with a growth duration less than 15 min. Raman spectra with different excitation wavelengths indicated that the as-grown short aligned SWCNTs showed high selectivity of metallic SWCNTs. Various kinds of materials, such as mica, quartz, Cu foil, and carbon fiber, can serve as the substrates for the growth of perpendicular FeMoMgAl LDH films and also the growth of the short aligned SWCNTs subsequently. These findings highlight the easy route for bulk preferential growth of aligned metallic-rich SWCNTs with well defined length for further bulk characterization and applications. This journal is © The Royal Society of Chemistry 2012

  14. Research Status on Reinforcement Connection Form of Precast Concrete Shear Wall Structure

    Science.gov (United States)

    Zhang, Zhuangnan; Zhang, Yan

    2018-03-01

    With the rapid development of Chinese economy and the speeding up the process of urbanization, housing industrialization has been paid more and more attention. And the fabricated structure has been widely used in China. The key of precast concrete shear wall structure is the connection of precast components. The reinforcement connection can directly affect the entirety performance and seismic behavior of the structure. Different reinforcement connections have a great impact on the overall behavior of the structure. By studying the characteristics of the reinforcement connection forms used in the vertical connection and horizontal connection of precast concrete shear wall, it can provide reference for the research and development of the reinforcement connection forms in the future.

  15. 24 CFR 92.252 - Qualification as affordable housing: Rental housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Qualification as affordable housing: Rental housing. 92.252 Section 92.252 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development HOME INVESTMENT PARTNERSHIPS PROGRAM Project Requirements § 92.252...

  16. 24 CFR 8.28 - Housing certificate and housing voucher programs.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Housing certificate and housing voucher programs. 8.28 Section 8.28 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development NONDISCRIMINATION BASED ON HANDICAP IN FEDERALLY ASSISTED PROGRAMS AND...

  17. Analysis of the semi-permanent house in Merauke city in terms of aesthetic value in architecture

    Science.gov (United States)

    Topan, Anton; Octavia, Sari; Soleman, Henry

    2018-05-01

    Semi permanent houses are also used called “Rumah Kancingan” is the houses that generally exist in the Merauke city. Called semi permanent because the main structure use is woods even if the walls uses bricks. This research tries to analyze more about Semi permanent house in terms of aesthethics value. This research is a qualitative research with data collection techniques using questionnaire method and direct observation field and study of literature. The result of questionnaire data collection then processed using SPSS to get the influence of independent variable against the dependent variable and found that color, ornament, shape of the door-window and shape of roof (independent) gives 97,1% influence to the aesthetics of the Semi permanent house and based on the output coefficient SPSS obtained that the dependent variable has p-value SPSS coefficient it is found that free variable has p-value < 0.05 which means independent variables have an effect on significant to aesthetic variable.

  18. Wood moisture monitoring during log house thermal insulation mounting

    Directory of Open Access Journals (Sweden)

    Pavla Kotásková

    2011-01-01

    Full Text Available The current designs of thermal insulation for buildings concentrate on the achievement of the required heat transmission coefficient. However, another factor that cannot be neglected is the assessment of the possible water vapour condensation inside the construction. The aim of the study was to find out whether the designed modification of the cladding structure of an existing log house will or will not lead to a risk of possible water vapour condensation in the walls after an additional thermal insulation mounting. The condensation could result in the increase in moisture of the walls and consequently the constructional timber, which would lead to the reduction of the timber construction strength, wood degradation by biotic factors – wood-destroying insects, mildew or wood-destroying fungi. The main task was to compare the theoretically established values of moisture of the constructional timber with the values measured inside the construction using a specific example of a thermal insulated log house. Three versions of thermal insulation were explored to find the solution of a log house reconstruction which would be the optimum for living purposes. Two versions deal with the cladding structure with the insulation from the interior, the third version deals with an external insulation.In a calculation model the results can be affected to a great degree by input values (boundary conditions. This especially concerns the factor of vapour barrier diffusion resistance, which is entered in accordance with the producer’s specifications; however, its real value can be lower as it depends on the perfectness and correctness of the technological procedure. That is why the study also includes thermal technical calculations of all designed insulation versions in the most unfavourable situation, which includes the degradation of the vapour barrier down to 10% efficiency, i.e. the reduction of the diffusion resistance factor to 10% of the original value

  19. Numerical Investigation of Floor Heating Systems in Low Energy Houses

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Kragh, Jesper; Jensen, Claus Franceos

    2002-01-01

    In this paper an investigation of floor heating systems is performed with respect to heating demand and room temperature. Presently (2001) no commercially available building simulation programs that can be used to evaluate heating demand and thermal comfort in buildings with building integrated....... The model calculates heating demand, room temperatures, and thermal comfort parameters for a person in the room. The model is based on a numerical Finite Control Volume (FCV) method for the heat transfer in walls, ceiling, windows and floor. The model uses both convective and radiative heat transfer...... to the room air and between the room surfaces. The simulation model has been used to calculate heating demand and room temperature in a typical well insulated Danish single-family house with a heating demand of approximately 6000 kWh per year, for a 130 m² house. Two different types of floor heating systems...

  20. Evaluation of Shear Wall-RC Frame Interaction of High-Rise Buildings using 2-D model Approach

    Directory of Open Access Journals (Sweden)

    Dipali Patel

    2015-09-01

    Full Text Available The usefulness of structural walls in the framing of buildings has long been recognized. It is generally preferred to use shear wall in combination with moment resisting frame. In the present study, an effort is also made to investigate the shear wall-RC frame interaction using 2-D modeling of 20, 30 and 35 storey RC frame building with shear wall. In equivalent simplified 2-D model, two exterior frames with shear wall modeled as single frame with double stiffness, strength and weight. The interior frames without shear wall are modeled as a single frame with equivalent stiffness, strength and weight. The modeled frames are connected with rigid link at each floor level. Using 2-D plane frame model the lateral force distribution between Exterior frame with shear wall and Interior frame without shear wall is investigated. From the analysis, it is observed that up to bottom seven/eight storey more than 50% load is taken by frame with shear wall and the lower most three storeys take about 75% of total storey shear.

  1. Integrated Strip Foundation Systems for Small Residential Buildings

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2010-01-01

    A prefabricated lightweight element was designed for a strip foundation that was used on site as the bases of two small residential buildings, in this case single-family houses; one was built with a double-brick exterior wall separated by mineral fiber insulation and the other was built with a wood...

  2. 24 CFR 982.617 - Shared housing: Rent and voucher housing assistance payment.

    Science.gov (United States)

    2010-04-01

    ... Special Housing Types Shared Housing § 982.617 Shared housing: Rent and voucher housing assistance payment... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Shared housing: Rent and voucher housing assistance payment. 982.617 Section 982.617 Housing and Urban Development Regulations Relating to...

  3. Assisted Housing - Public Housing Authorities - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — Public Housing was established to provide decent and safe rental housing for eligible low-income families, the elderly, and persons with disabilities. Public housing...

  4. Measured airtightness of twenty-four detached houses over periods of up to three years

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    A three year field study of 20 energy efficient houses and four conventional dwellings was conducted in Winnipeg, Manitoba to evaluate the performance of their building envelope systems. Ten of the houses were built with polyethylene air barriers and 14 using the Airtight Drywall Approach (ADA). All were newly constructed and used dry wood for the framing members with a wood moisture content (WMC) below 19 percent. Building envelope performance was evaluated by developing a comprehensive monitoring program which included measurements of wall, attic, and floor joist WMC levels, detailed thermographic examinations and regular airtightness testing. Over 13,000 WMC measurements were performed, 1,013 thermographic images recorded, and 167 airtightness tests conducted.

  5. Housing culture

    DEFF Research Database (Denmark)

    Roesdahl, Else; Scholkmann, Barbara

    2007-01-01

    On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies.......On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies....

  6. Remedial measures in Czech houses with high radium content in building material

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    1999-01-01

    Three groups of houses built from materials having elevated natural radioactivity content were found in the Czech republic. These are: 1) about hundred old houses in Jachymov (Joachimstal) in Northern Bohemia, where residues from factory producing uranium paints were used as plaster and mortar before the World War II (radium concentration up to 1 MBq/kg, indoor gamma dose rate up to 10-100 μGy/h); 2) some 20 000 family houses built from highly emanating aerated concrete with radium content 500-1000 Bq/kg (produced from flying ash) in the period 1963-1980; 3) more than 2000 family houses from slag concrete of radium content about 3 kBq/kg in average (indoor gamma dose rate up to 2 μGy/h) made in the period 1972-83. Remedy measures were undertaken with state financial support. Intervention levels were laid down 200 Bq/m 3 for EEC (equivalent equilibrium radon concentration - it is equivalent to radon gas concentration 500 Bq/m 3 ), 2 μGy/h for indoor gamma dose rate. Weighted sum of indoor radon and indoor gamma dose rate was used if the latter was above 0,5 μGy/h. The central heat recovery ventilation units were used largely as the remedy measures. Some houses were demolished, in some houses local contamination of plasters was removed. Other tested measures (removal of the contaminated building material in great amount, gamma shielding, wall coating, etc.) proved to be not effective or not acceptable in practice. (author)

  7. Use of radiometer to reform and repair an old living house to passive solar one

    Science.gov (United States)

    Okamoto, Yoshizo; Inagaki, Terumi; Suzuki, Takakazu; Kurokawa, Takashi

    1994-03-01

    Japanese living houses mainly consist of wooden elements in high-temperature and moist conditions. To modify the hot and humid environment, a conventional old house was partially rebuilt and repaired. Especially in the winter season, a diagnostic thermographic test was used to find deteriorated and leaking parts of interior and exterior walls. Macroscopic deteriorated parts were checked again in detail. The deteriorated element was then removed. During the reconstruction process, a new solar heat and air conditioning system using a silica-gel adsorber and underground water was installed to cool and warm up the living room. Thermography tests of this remodeled house show that room temperature is always constant and mild to human beings, especially in the winter. Temperature and heat flow distribution of flowing air in the living room was measured using thermal net and wire methods. Leaking thermal streak flow of the gap was locally visualized by the IR radiometer and a highly sensitive video camera. It was verified that IR thermography is a useful measuring instrument to check thermal defects of a house.

  8. Bioclimatic building in Hungary: results of the Pecs house

    Energy Technology Data Exchange (ETDEWEB)

    Fueloep, L.; Szasz, J. (Pollack Mihaly Coll. of Technology, Pecs (HU))

    1990-09-01

    The house was designed on a split-level to fit into a slope, with close attention paid to the reduction of heat losses, the increasing of passive gains and the maintenance of bioclimatic comfort. The building's rounded contours reduce turbulence and edge effects. A totally glazed south side incorporates two thermosyphon mass walls as well as a two-storey high sunspace. This unheated intermediate space acts as a buffer between indoors and outdoors and maximises solar gain, which can however be controlled by internal shading. A fan assisted central gravel packed tower and a rock bed floor provide heat storage. There are two 18 m{sup 2} areas of thermosyphon walls, where glass on polycarbonate is used to cover 0.45 m of dark stone mass. In 1989 the glazed wall was retrofitted to incorporate honeycomb transparent insulation, which still allows radiation gain but minimizes heat loss. Transparent insulation is also used in a skylight which is important for lighting the hallway but which would otherwise contribute to heat loss. Natural and forced ventilation as well as a cool air-pond contributes to cooling. Auxiliary floor heating is supplied by gas. In one room underfloor PCM batteries charged by discount night electricity are used for heating. A fireplace is also provided. (author).

  9. 24 CFR 982.606 - Congregate housing: Who may reside in congregate housing.

    Science.gov (United States)

    2010-04-01

    ... Special Housing Types Congregate Housing § 982.606 Congregate housing: Who may reside in congregate housing. (a) An elderly person or a person with disabilities may reside in a congregate housing unit. (b... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Congregate housing: Who may reside...

  10. Airway wall thickness of allergic asthma caused by weed pollen or house dust mite assessed by computed tomography.

    Science.gov (United States)

    Liu, Liping; Li, Guangrun; Sun, Yuemei; Li, Jian; Tang, Ningbo; Dong, Liang

    2015-03-01

    Little was known about Airway wall thickness of asthma patients with different allergen allergy. So we explored the possible difference of Airway wall thickness of asthma patients mono-sensitized to weed pollen or HDM using high-resolution computed tomography. 85 severe asthma patients were divided into weed pollen group and HDM group according to relevant allergen. 20 healthy donors served as controls. Airway wall area, percentage wall area and luminal area at the trunk of the apical bronchus of the right upper lobe were quantified using HRCT and compared. The values of pulmonary function were assessed as well. There were differences between HDM group and weed pollen group in WA/BSA,WA% and FEF25-75% pred, and no significant difference in FEV1%pred, FEV1/FVC and LA/BSA. In weed pollen group, WA/BSA was observed to correlate with the duration of rhinitis, whereas in HDM group, WA/BSA and LA/BSA was observed to correlate with the duration of asthma. In weed pollen group, FEV1/FVC showed a weak but significant negative correlation with WA%, but in HDM group FEV1/FVC showed a significant positive correlation with WA% and a statistical negative correlation with LA/BSA. FEV1/FVC and FEF25-75% pred were higher and WA/BSA and LA/BSA were lower in healthy control group than asthma group. FEV1%pred and WA% was no significant difference between asthma patients and healthy subjects. There are differences between HDM mono-sensitized subjects and weed pollen mono-sensitized subjects, not only in airway wall thickness, but also small airway obstruction. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Mass Housing and Changings in Housing Demand, Case of Diyarbakir, Turkey

    OpenAIRE

    M. Oguz Sinemillioglu; Can Tuncay Akın; Havva Özyılmaz

    2005-01-01

    The aim of this study is to analyze changings in housing demand, especially in term of house size in Diyarbakır case, in Turkey. Though Housing in Turkey is in a free market system, there is a Mass Housing Administration (TOKÃ ) has been doing mass houses for, relatively, middle class income people. Diyarbakır, one of the cities that TOKÃ has done two thousand houses, has taken too much migration, so that the demand in housing form and structure has different alterations. This process should ...

  12. Housing Conditions Contribute to Underweight in Children: An Example From Rural Villages in Southeast Sulawesi, Indonesia.

    Science.gov (United States)

    Tasnim, Tasnim; Dasvarma, Gouranga; Mwanri, Lillian

    2017-09-01

    The prevalence of underweight in children under 5 years of age is anomalously high in Konawe District, Southeast Sulawesi Province, Indonesia. This state of affairs may be related to poor housing conditions, such as limited access to clean water, the absence of a sanitary latrine, and the use of poor housing materials. Therefore, this study aimed to examine the effect of housing conditions on underweight in under-5 children in Konawe District. This study was conducted in 2013 in 5 health centres in Konawe District, Southeast Sulawesi Province, and used a case-control study design. The study recruited 400 under-5 children, including 100 of whom were cases and 300 of whom were age-matched controls (1:3). Cases were underweight children, while the controls were children with a normal nutritional status. The independent variables were the availability and types of water and latrine facilities and housing materials (roof, wall, and floor). The statistical analysis used Cox regression. A lack of water availability (odds ratio [OR], 5.0; 95% confidence interval [CI], 2.7 to 9.5; pavailability in the home (OR, 2.5; 95% CI, 1.5 to 4.0; p<0.001), and poor-quality roofing materials (OR, 1.7; 95% CI, 1.1 to 2.7; p<0.02) significantly contributed to underweight in children. In contrast, the walls and the floors did not contribute to under-5 year children being underweight (p=0.09 and p=0.71, respectively). Sanitation facilities and roofing were identified as important factors to address in order to improve children's nutritional status. Children's health status was directly impacted by food intake via their nutritional status.

  13. CDBG Housing Activity

    Data.gov (United States)

    Department of Housing and Urban Development — CDBG activity related to housing, including multifamily rehab, housing services, code enforcement, operation and repair of foreclosed property and public housing...

  14. Assessment of housing design decisions in informal housing ...

    African Journals Online (AJOL)

    The rapid urbanisation of cities in developing countries has witnessed a growth in the volume of housing construction in the urban areas. The demand for housing and the inability of government to meet this demand has encouraged the growth of informal housing. The concept of healthy buildings is of great importance, ...

  15. Conjugate heat transfer for turbulent flow in a thick walled plain pipe

    Directory of Open Access Journals (Sweden)

    Canli Eyub

    2018-01-01

    Full Text Available Laminar and turbulent flow have their own characteristics in respect of heat transfer in pipes. While conjugate heat transfer is a major concern for a thick walled pipe with laminar flow inside it, there are limited studies about a turbulent flow in a thick walled plain pipe considering the conjugate heat transfer. In order to conduct such a work by means of in-house developed code, it was desired to make a preliminary investigation with commercially available CFD codes. ANSYS CFD was selected as the tool since it has a positive reputation in the literature for reliability. Defined heat transfer problem was solved with SIMPLE and Coupled Schemes for pressure velocity coupling and results are presented accordingly.

  16. Double product and end-organ damage in African and Caucasian men: the SABPA study.

    Science.gov (United States)

    Schultz, A J; Schutte, A E; Schutte, R

    2013-08-10

    Increasing urbanisation in sub-Saharan African countries is causing a rapid increase in cardiovascular disease. Evidence suggests that Africans have higher blood pressures and a higher prevalence of hypertension-related cardiovascular morbidity and mortality, compared to Caucasians. We investigated double product (systolic blood pressure × heart rate), a substantial measure of cardiac workload, as a possible cardiovascular risk factor in African and Caucasian men. The study consisted of 101 urbanised African and 101 Caucasian male school teachers. We measured 24h ambulatory blood pressure and the carotid cross-sectional wall area, and determined left ventricular hypertrophy electrocardiographically by means of the Cornell product. Urinary albumin and creatinine were analysed to obtain the albumin-to-creatinine ratio. Africans had higher 24h, daytime and nighttime systolic- and diastolic blood pressure, heart rate and resultant double product compared to the Caucasians. In addition, markers of end-organ damage, albumin-to-creatinine ratio and left ventricular hypertrophy were higher in the Africans while cross-sectional wall area did not differ. In Africans after single partial and multiple regression analysis, 24h systolic blood pressure, but not double product or heart rate, correlated positively with markers of end-organ damage (cross-sectional wall area: β=0.398, P=0.005; left ventricular hypertrophy: β=0.455, Pproduct may not be a good marker of increased cardiovascular risk when compared to systolic blood pressure in African and Caucasian men. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Situation-Based Housing

    DEFF Research Database (Denmark)

    Duelund Mortensen, Peder

    2011-01-01

    Presentation of urban housing research on flexible housing types in the Copenhagen Region: Theoretical background, methodology, analyse of spatial organization, interviews and results. Cases: Pærehaven in Ølby, Køge and M-house in Ørestad, Copenhagen......Presentation of urban housing research on flexible housing types in the Copenhagen Region: Theoretical background, methodology, analyse of spatial organization, interviews and results. Cases: Pærehaven in Ølby, Køge and M-house in Ørestad, Copenhagen...

  18. Near Zero Energy House (NZEH) Design Optimization to Improve Life Cycle Cost Performance Using Genetic Algorithm

    Science.gov (United States)

    Latief, Y.; Berawi, M. A.; Koesalamwardi, A. B.; Supriadi, L. S. R.

    2018-03-01

    Near Zero Energy House (NZEH) is a housing building that provides energy efficiency by using renewable energy technologies and passive house design. Currently, the costs for NZEH are quite expensive due to the high costs of the equipment and materials for solar panel, insulation, fenestration and other renewable energy technology. Therefore, a study to obtain the optimum design of a NZEH is necessary. The aim of the optimum design is achieving an economical life cycle cost performance of the NZEH. One of the optimization methods that could be utilized is Genetic Algorithm. It provides the method to obtain the optimum design based on the combinations of NZEH variable designs. This paper discusses the study to identify the optimum design of a NZEH that provides an optimum life cycle cost performance using Genetic Algorithm. In this study, an experiment through extensive design simulations of a one-level house model was conducted. As a result, the study provide the optimum design from combinations of NZEH variable designs, which are building orientation, window to wall ratio, and glazing types that would maximize the energy generated by photovoltaic panel. Hence, the design would support an optimum life cycle cost performance of the house.

  19. 24 CFR 8.25 - Public housing and multi-family Indian housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Public housing and multi-family Indian housing. 8.25 Section 8.25 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development NONDISCRIMINATION BASED ON HANDICAP IN FEDERALLY ASSISTED PROGRAMS AND...

  20. Sustained housing-type social buffering following social housing in male rats.

    Science.gov (United States)

    Kiyokawa, Yasushi; Ishida, Aya; Takeuchi, Yukari; Mori, Yuji

    2016-05-01

    In social animals, recovery from the adverse effects of distressing stimuli is promoted by subsequent cohousing with a conspecific animal(s). This phenomenon has been termed housing-type social buffering. We previously found that social housing induced housing-type social buffering in fear-conditioned male rats. This buffering took the form of attenuated conditioned hyperthermia in response to an auditory conditioned stimulus (CS). Here, we assessed whether this social buffering is sustained even if the subject is housed alone after a period of social housing. When fear-conditioned subjects were housed alone during a 48-h period between conditioning and re-exposure to the auditory CS, they exhibited conditioned hyperthermia in response to the CS. However, conditioned hyperthermia was not observed when the 12-h period of social housing began 24 and 36h after conditioning during the 48-h period. This was not the case when the 12-h period of social housing began 0 and 12h after the conditioning. These results suggest that housing-type social buffering is sustained for 12h after the 12-h period of social housing. We next considered whether increasing the duration of social housing would extend the period of social buffering. We observed social buffering of conditioned hyperthermia 24 and 48, but not 96h after a 24-h period of social housing. These results suggest that social buffering was extended when the duration of social housing was increased. Taken together, our findings indicate that housing-type social buffering is sustained after a period of social housing. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Active house concept versus passive House

    NARCIS (Netherlands)

    Zeiler, W.; Boxem, G.; Vehler, R.; Verhoeven, M.; Fremouw, M.

    2009-01-01

    The passive house concept is the present trend in energy efficient sustainable dwellings. Within the passive house concept every effort is made to minimize the energy use. Substantial savings can be achieved by passive energy systems, especially natural ventilation, summer shading and winter solar

  2. Feedback control of resistive wall modes in toroidal devices

    International Nuclear Information System (INIS)

    Liu, Y.Q.

    2002-01-01

    Active feedback of resistive wall modes is investigated using cylindrical theory and toroidal calculations. For tokamaks, good performance is obtained by using active coils with one set of coils in the poloidal direction and sensors detecting the poloidal field inside the first wall, located at the outboard mid-plane. With suitable width of the feedback coil such a system can give robust control with respect to variations in plasma current, pressure and rotation. Calculations are shown for ITER-like geometry with a double wall. The voltages and currents in the active coils are well within the design limits for ITER. Calculations for RFP's are presented for a finite number of coils both in the poloidal and toroidal directions. With 4 coils in the poloidal and 24 coils in the toroidal direction, all non-resonant modes can be stabilized both at high and low theta. Several types of sensors, including radial and internal poloidal or toroidal sensors, can stabilize the RWM, but poloidal sensors give the most robust performance. (author)

  3. Selective Internal Heat Distribution in Modified Trombe Wall

    Science.gov (United States)

    Szyszka, Jerzy; Kogut, Janusz; Skrzypczak, Izabela; Kokoszka, Wanda

    2017-12-01

    At present, the requirements for thermal insulation of the external walls in buildings are being increased. There is a need to reduce energy consumption for heating rooms during the winter season. This may be achieved by increasing the thermal resistance of the outer partitions, using solutions that utilize either recuperation or solar radiation. The most popular systems include either solar collectors, or heat pump links or ground exchangers. Trombe walls (TW) are a very promising passive heating system, which requires little or no effort to operate, and may be very convenient in different climate conditions. A typical TW consists of a masonry wall painted a dark, heat absorbing paint colour and faced with a single or double layer of glass. The principle of operation is based on the photothermal conversion of solar radiation. There are various modifications of TW. They may improve the energy efficiency in relation to the climate conditions in which they operate. The hybrid solutions are also known. The efficiency of walls is related to the use of proper materials. In TW, the compromise should be sought between the thermal resistance and the ability to distribute heat from the absorbed energy of solar radiation. The paper presents an overview of the most commonly used solutions and discusses its own concept dedicated to the climate conditions of Central Europe.

  4. Customer Need ́s Satisfaction in the Housing Sector: the Case of the Toluca Valley

    Directory of Open Access Journals (Sweden)

    Delgado-Hernández David Joaquín

    2013-10-01

    Full Text Available Currently, the construction sector faces great challenges, as the recent economic contraction has directly impacted this industry, and only companies that can offer quality products and services will survive in today’s highly competitive markets. In particular, the housing sector has to find ways to meet the needs of its customers due to the number of firms competing in this arena. There are some studies that quantify the demand for housing as well as those that reveal the number of homes sold per year in a region. However, investigations in Mexico to establish the level of cus- tomer satisfaction with their homes are still scarce. Thus, the main objective of this research is to determine the level of customer satisfaction in the Toluca Valley ́s housing sector (a region located 60 km west of Mexico City, in low income projects developed by Mexican construction companies. Having applied a questionnaire to users from seventy eight houses within eight different projects, some issues were identified that builders could improve, and take into account during the design stage of new housing developments. Among the main ones are: insulation, wall and ceil- ing materials, space distribution, and house ́s size. In contrast, residents are rela- tively satisfied with: the ease of cleaning, the aesthetics of the projects and the proximity to schools and supermarkets.

  5. Laccase electrodes based on the combination of single-walled carbon nanotubes and redox layered double hydroxides: Towards the development of biocathode for biofuel cells

    Science.gov (United States)

    Ding, Shou-Nian; Holzinger, Michael; Mousty, Christine; Cosnier, Serge

    Single-walled carbon nanotubes (SWCNT) were combined with layered double hydroxides (LDH) intercalated with 2,2‧-azino-bis(3-ethylbenzothiazoline-6-sulfonate) diammonium salt [ZnCr-ABTS] to entrap and electrically connect laccase enzyme. The resulting laccase electrodes exhibited an electro-enzymatic activity for O 2 reduction. To improve this electrocatalytic activity, varying SWCNT quantities and loading methods were tested to optimize the configuration of the laccase electrodes. Furthermore, the resulting bioelectrode was successfully used as a biocathode for the elaboration of a membrane-less glucose/air biofuel cell. In 0.1 M phosphate buffer (PBS) of pH 6.0, containing glucose (5 mM) under ambient conditions, the assembled biofuel cell yielded a maximum power density of 18 μW cm -2 at a cell voltage of 0.3 V whereas this power decreased to 8.3 μW cm -2 for a biofuel cell based on the identical biocathode setup without SWCNT.

  6. Laccase electrodes based on the combination of single-walled carbon nanotubes and redox layered double hydroxides: Towards the development of biocathode for biofuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Shou-Nian; Holzinger, Michael; Cosnier, Serge [Departement de Chimie Moleculaire UMR-5250, ICMG FR-2607, CNRS Universite Joseph Fourier, BP-53, 38041 Grenoble Cedex 9 (France); Mousty, Christine [Laboratoire des Materiaux Inorganiques, Universite Blaise Pascal, CNRS UMR-6002, 63177 Aubiere Cedex (France)

    2010-08-01

    Single-walled carbon nanotubes (SWCNT) were combined with layered double hydroxides (LDH) intercalated with 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonate) diammonium salt [ZnCr-ABTS] to entrap and electrically connect laccase enzyme. The resulting laccase electrodes exhibited an electro-enzymatic activity for O{sub 2} reduction. To improve this electrocatalytic activity, varying SWCNT quantities and loading methods were tested to optimize the configuration of the laccase electrodes. Furthermore, the resulting bioelectrode was successfully used as a biocathode for the elaboration of a membrane-less glucose/air biofuel cell. In 0.1 M phosphate buffer (PBS) of pH 6.0, containing glucose (5 mM) under ambient conditions, the assembled biofuel cell yielded a maximum power density of 18 {mu}W cm{sup -2} at a cell voltage of 0.3 V whereas this power decreased to 8.3 {mu}W cm{sup -2} for a biofuel cell based on the identical biocathode setup without SWCNT. (author)

  7. Satisfaction with housing and housing support for people with psychiatric disabilities.

    Science.gov (United States)

    Brolin, Rosita; Rask, Mikael; Syrén, Susanne; Baigi, Amir; Brunt, David Arthur

    2015-01-01

    The aim of this study was to investigate the degree of satisfaction with housing and housing support for people with psychiatric disabilities in Sweden. A total of 370 residents, in supported housing and in ordinary housing with housing support, completed a new questionnaire and reported a high degree of overall satisfaction, but many of them wanted to move somewhere else. Differences were found between the two different types of housing concerning satisfaction with housing support, social life and available choices. Security and privacy, as well as other's influence on the choice of residential area and dwelling proved to be important predictors for satisfaction.

  8. Thermal energy storage and losses in a room-Trombe wall system located in Mexico

    International Nuclear Information System (INIS)

    Hernández-López, I.; Xamán, J.; Chávez, Y.; Hernández-Pérez, I.; Alvarado-Juárez, R.

    2016-01-01

    A thermal evaluation of a R-TW system (room with a Trombe wall) is presented. Hourly climatic data of the coldest and the warmest days of 2014 was used to assess the behavior of the R-TW in two cities of Mexico with cold climate (Huitzilac and Toluca). The simulations were done with an in-house code based on the Finite Volume Method. It was found that thermal energy losses through the semitransparent wall are about 60% of the solar radiation incident on the system (G_s_o_l). Despite of the thermal losses, the system gets enough energy to keep the air inside the room with a temperature above 35 °C. For both cities during the coldest day, the maximum energy stored is about 109 MJ and during the warmest day is about 70 MJ. This energy is supplied from the storage wall to the air inside the room during periods without insolation. - Highlights: • Thermal performance of a Room-Trombe Wall system was evaluated under two cold cities. • Thermal energy losses through the semitransparent wall were about 60% of the solar radiation incident of the system. • The maximum energy stored by the Trombe Wall was 109 MJ during the coldest day. • The maximum energy stored by the Trombe Wall was 70 MJ during the warmest day.

  9. Optimum value engineering and integrated design methods for reducing the cost of R-2000 houses

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G. [Proskiw Engineering Ltd., Winnipeg, MB (Canada); Parekh, A. [Natural Resources Canada, Ottawa, ON (Canada)

    2009-07-01

    Opportunities exist to reduce the incremental cost of R-2000 construction by using optimum value engineering (OVE) and integrated design (ID) techniques. OVE is a construction philosophy in which components and systems are designed to meet their intended purposes without excessive or unnecessary use of resources. This paper summarized a study that was designed to identify opportunities for reducing the costs of R-2000 houses while improving their performance. These included detailed energy and cost analysis of various OVE/ID options which were then applied to a sample of 18 representative new home designs from British Columbia, Manitoba, and New Brunswick. The paper described the OVE/ID measures studied, cost analysis, measure utilization and energy analysis. It also included a detailed discussion of individual OVE/ID measures. Examples of some of these measures were the elimination of floor system cross-bridging; support of non-load bearing partition walls; engineered wood beams; drywall clips at corners; and non-load bearing partition walls. It was concluded that significant opportunities exist to reduce the incremental cost of R-2000 houses through careful application of OVE and ID practices. 5 refs., 4 tabs., 1 fig.

  10. The traditional irrigation technique of Lake Garda lemon--houses (Northern Italy)

    Science.gov (United States)

    Barontini, Stefano; Vitale, Nicola; Fausti, Federico; Bettoni, Barbara; Bonati, Sara; Peli, Marco; Pietta, Antonella; Tononi, Marco; Ranzi, Roberto

    2016-04-01

    Between 16th and 19th centuries the North-Western side of Lake Garda was seat of an important district which, at the time of its maximum splendour between 18th and 19th centuries, produced and exported lemons and citrus even toward the Northern Europe and the Russia. The limonaie del Garda (Lake-Garda lemon-houses), the local name of the citrus orchards, were settled on terraces built on steep slopes, with landfill taken from the Eastern side of the lake, and closed by greenhouses during late autumn and winter in order to protect the cultivations. The terraces were built nearby streams, they were South-Eastern exposed and protected by walls from the cold winds. Thanks in fact to the Lake Garda microclimate, lemon trees were not cultivated in pots, as in the typical orangeries of mid-latitudes Europe, but directly in the soil. Here the citrus cultivation technique reached a remarkably high degree of standardisation, with local cultivar as the Madernino or lemon from Maderno, and it involved, as in modern industrial districts, all the surrounding land in order to satisfy the needing of required materials to build the terraces, the walls, the greenhouses and the wooden frames to hold the branches laden with fruits. Due to the great water requirement of lemon trees during summer, which is estimated to range from 150 to 300 ℓ every ten days, the water management played a key role in the cultivation technique. The traditional irrigation technique was standardized as well. During our surveys, we observed that most of the lemon-houses still conserve little stone flumes along the walls upslope to the terraces, with spillways every adult tree, i.e. about every 4 m. The flumes were filled with water taken from an upstream reservoir, built nearby a stream. The spillways were activated with a backwater obtained by means of a sand bag placed within the flume, just downstream to the spillway itself. In order to avoid any excavation, spilled water was driven to the base of each

  11. Characterisation and in vivo ecotoxicity evaluation of double-wall carbon nanotubes in larvae of the amphibian Xenopus laevis

    International Nuclear Information System (INIS)

    Mouchet, Florence; Landois, Perine; Sarremejean, Elodie; Bernard, Guillaume; Puech, Pascal; Pinelli, Eric; Flahaut, Emmanuel; Gauthier, Laury

    2008-01-01

    Because of their outstanding properties, carbon nanotubes (CNTs) are being assessed for inclusion in many manufactured products. Due to their massive production and growing number of potential applications, the impact of CNTs on the environment must be taken into consideration. The present investigation evaluates the ecotoxicological potential of double-walled carbon nanotubes (DWNTs) in the amphibian larvae Xenopus laevis at a large range of concentrations in water (from 10 to 500 mg L -1 ). Acute toxicity and genotoxicity were analysed after 12 days of static exposure in laboratory conditions. Acute toxicity was evaluated according to the mortality and the growth of larvae. The genotoxic effects were analysed by scoring the micronucleated erythrocytes of the circulating blood of larvae according to the International Standard micronucleus assay. Moreover, histological preparations of larval intestine were prepared after 12 days of exposure for observation using optical and transmission electron microscopy (TEM). Finally, the intestine of an exposed larva was prepared on a slide for analyse by Raman imaging. The results showed no genotoxicity in erythrocytes of larvae exposed to DWNTs in water, but acute toxicity at every concentration of DWNTs studied which was related to physical blockage of the gills and/or digestive tract. Indeed, black masses suggesting the presence of CNTs were observed inside the intestine using optical microscopy and TEM, and confirmed by Raman spectroscopy analysis. Assessing the risks of CNTs requires better understanding, especially including mechanistic and environmental investigations

  12. Dosimetric characteristics of the Best registered double-wall 103Pd brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, A.S.; Bharucha, Z.; Yoe-Sein, M.; Sowards, Keith

    2001-01-01

    103 Pd and 125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, a double-wall 103 Pd source has been introduced, which has a design different from that of sources presently on the market. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined following the AAPM Task Group 43 recommendations and were related to the October 10, 2000 revision of the NIST 1999 S K Standard for 103 Pd. Measurements were performed in a Solid Water trade mark sign phantom using LiF thermoluminescent dosimeters. For these measurements, slabs of Solid Water trade mark sign phantom material were machined to accommodate the source and LiF TLD chips of dimensions (3.1x3.1x0.8 mm 3 ) and (1.0x1.0x1.0 mm 3 ). The TLD chips were surrounded by at least 10 cm of Solid Water trade mark sign phantom material to provide full scattering conditions. The Monte Carlo simulations were performed in Solid Water trade mark sign and liquid water using the PTRAN code. The results of this investigation show an excellent agreement (within 5%) between the measured (0.67±8% cGy h -1 U -1 ) and calculated (to be 0.65±3% cGy h -1 U -1 ) dose rate constant in Solid Water trade mark sign . The Monte Carlo calculated dose rate constant of the Best registered 103 Pd in water was found to be 0.67±0.02 cGy h -1 U -1 . The radial dose function, g(r), of the new 103 Pd source was measured at distances ranging from 0.5 and 7 cm using LiF TLD in Solid Water trade mark sign phantom material. Moreover, the radial dose function of the new source was calculated in liquid water and Solid Water trade mark sign at distances ranging from 0.1 to 7 cm using the PTRAN Monte Carlo Code. The anisotropy function, F(r,θ), of the new 103 Pd source was also measured in Solid Water trade mark sign and calculated in both Solid Water trade mark sign and water phantom material

  13. Air Motion and Thermal Environment in Pig Housing Facilities with Diffuse Inlet

    DEFF Research Database (Denmark)

    Jacobsen, Lis

    A ventilation system with ambient air supply through diffuse ceiling used in pig production facilities is presented. The climatic conditions were examined both experimentally and numerically in an full scale experimental room and the inlet boundary conditions of the diffuse inlet were examined...... in ambient temperature and air exchange rate. The effect of housing equipment on environmental conditions has been examined both experimental and numerically and it was found that impervious housing equipment has a significant effect on the climatic conditions close to the wall in the occupational zone...... in a wind tunnel model. In the full scale experiments the focus has been on the correlation between variations in ambient climatic conditions and changes in environmental condition in the occupational zone. It was found that the environmental conditions in the occupational zone were independent on changes...

  14. Design and execution of double slits type straight caisson at exclusive harbors of Ooma nuclear power plant

    International Nuclear Information System (INIS)

    Tsukamoto, Kunihiro; Yamamoto, Morikuni; Naruoka, Masayoshi; Matsubara, Takayuki

    2004-01-01

    Ooma nuclear power plant is going to build the exclusive harbors, of which west breakwater is a double slits type straight caisson bank (double slits caisson). It contains double transmission walls and retarding rooms, which show large effect of breaker, because the reflected wave height of short-period component is decreased in the rear retarding room and one of long-period component decreased in both retarding rooms. Accordingly, it is seemed to be proved larger effect of breaker than one slit type caisson. Outline of harbors construction, adoption of double slits caisson, design of caisson, construction of caisson and installation are stated. The effect of breaker of double slits caisson is shown. (S.Y.)

  15. Development of a Measure of Housing and Housing Services.

    Science.gov (United States)

    Clark, Colleen; Young, M Scott; Teague, Gregory; Rynearson-Moody, Sarah

    2016-01-01

    The Housing Program Measure (HPM) was designed to document critical elements of a range of housing program types and associated services. Qualitative methods, including literature review and open-ended interviews, were used to determine pertinent HPM domains and to develop the pool of items. The measure was pre-tested, and reliability and validity analyses were applied to revise and strengthen the measure. The resulting measure furthers homelessness research by providing a tool that can be used to define housing and housing services interventions across diverse projects and disciplines, to facilitate program management by matching housing resources to the needs of homeless individuals, and to support model development by measuring progress to goals.

  16. Numerical analysis for temperature profile of the closed house using computational fluid dynamics

    Science.gov (United States)

    Setiadi, Rizki; Munadi, Tauviqirrahman, Mohammad

    2018-03-01

    This study aims to analyze the air temperature distribution in the closed house system for broiler using ABAQUS CFD Model. The obtained data is used for placing the temperature sensor before making the control system for the closed house. The dimesion of the experimental house was 30 m × 12 m × 2 m (length × width × height) which could be occupied by 7.500 broiler. The wall was made from expose mercy brick and curtain, ventilation system used 7 exhaust fan with diameter 1 m and 2 cooling unit, the roof was made from wood, and system used 45 of 7 watt lamp. The results of the analysis show that temperature distribution occurs on temperature 21-33.5°C and still relatively comfortable for broiler at the age of 1-21days. The air temperature distribution near the cooling unit is lower and increases to near the exhaust fan. In addition, the air temperature in the area near the roof is more high than others.

  17. Measurement of peripheral plasma using double probe in TRIAM-IM

    International Nuclear Information System (INIS)

    Yamagami, Masahiro; Kawasaki; Shoji; Jyotaki, Eriko; Fujita, Takaaki; Sakamoto, Mizuki; Nakamura, Kazuo; Nakamura, Yukio; Ito, Satoshi

    1994-01-01

    Behind the poloidal limiter of the TRIAM-IM, the change with time lapse of the electron temperature and the plasma density at the time of OH discharge was examined by using a double probe. Scrape-off plasma parameters, namely the correlations of electron temperature, plasma density and ion flux with main plasma parameters were obtained. It was found that scrape-off density is almost proportional to square of beam average electron density. Further, it was determined by calculation that the density on the outermost shell magnetic surface is about 1.5 x 10 15 /m 2 . In the TRIAM-IM, it is expected that accompanying the increase of plasma current at the time of OH discharge, the effects of thermal load and particle load given to the limiter and the first wall increase, and the increase of the metallic impurities due to sputtering becomes a serious problem. The merits of double probe method are explained. The objective of this experiment is to examine the temperature and density of the plasma that comes in contact with the limiter and the wall by determining the basic parameters of peripheral plasma at the time of OH discharge. In order to heighten the reliability of data, the examination was carried out from both aspects of hardware and software. The TRIAM-IM, double probe measuring system and its theory, applied voltage sweeping part, signal processing system, data processing system, and the experimental results of scrape-off layer parameters are described. (K.I.)

  18. Full scale tests of moisture buffer capacity of wall materials

    DEFF Research Database (Denmark)

    Mortensen, Lone Hedegaard; Rode, Carsten; Peuhkuri, Ruut Hannele

    2005-01-01

    that are harmful such as growth of house dust mites, surface condensation and mould growth. Therefore a series of experiments has been carried out in a full scale test facility to determine the moisture buffer effect of interior walls of cellular concrete and plaster board constructions. For the cellular concrete......Moisture buffer capacity of hygroscopic materials can be used to moderate peaks in the relative humidity (RH) of indoor air as well as moisture content variations in building materials and furnishing. This can help to ensure healthier indoor environments by preventing many processes...... of the changes of moisture content in specimens of the wall composites exposed to the same environment. It was found that the finishes had a big impact on the buffer performance of the underlying materials. Even though the untreated cellular concrete had a very high buffer capacity, the effect was strongly...

  19. Sydney Opera House Rise

    DEFF Research Database (Denmark)

    2013-01-01

    Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House".......Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House"....

  20. Economic analysis of passive houses and low-energy houses compared with standard houses

    International Nuclear Information System (INIS)

    Audenaert, A.; Cleyn, S.H. de; Vankerckhove, B.

    2008-01-01

    As the energy demand used for space heating accounts for 78% of EU15 household delivered energy consumption, significant reductions in energy demand can be achieved by promoting low-energy buildings. Our study investigates three building types: the standard house, the low-energy house and the passive house. As more far-reaching measures concerning energy savings usually lead to higher investments, the aim of our study is to perform an economic analysis in order to determine the economic viability of the three building types

  1. Assisted Housing - Public Housing Developments - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The general location of an entire Public Housing Development. A distinct address is chosen to represent the general location of an entire Public Housing Development,...

  2. Wall Climbing Robot Using Electrostatic Adhesion Force Generated by Flexible Interdigital Electrodes

    Directory of Open Access Journals (Sweden)

    Rong Liu

    2013-01-01

    Full Text Available Electrostatic adhesion technology has broad application prospects on wall climbing robots because of its unique characteristics compared with other types of adhesion technologies. A double tracked wall climbing robot based on electrostatic adhesion technology is presented including electrode panel design, mechanical structure design, power supply system design and control system design. A theoretical adhesion model was established and the electrostatic potential and field were expressed by series expansions in terms of solutions of the Laplace function. Based on this model, the electrostatic adhesion force was calculated using the Maxwell stress tensor formulation. Several important factors which may influence the electrostatic adhesion force were analysed and discussed by both FEM simulation and theoretical calculation. In addition, experiments on the adhesion performance of the electrode panel and the climbing performance of the robot on various wall materials were carried out. Both the simulation and experiment results verify the feasibility of electrostatic adhesion technology being applied on wall climbing robots. The theoretical model and calculation method for the electrostatic adhesion force proposed in this paper are also justified.

  3. Digital front-end electronics for COMPASS Muon-Wall 1 detector

    International Nuclear Information System (INIS)

    Alekseev, G.D.; Zhuravlev, N.I.; Maggiora, A.

    2005-01-01

    The digital front-end electronics for the COMPASS Muon-Wall 1 (CERN) detector is described. The digital card has been designed on the basis of the TDC chip F1. One card includes 6 F1 chips (192 channels), bus arbiter, DAC, power supply distribution, hot-link interface. The total number of the digital cards in the system is 44 housed in 5 euro-crates (6U), the total number of readout channels is 8448. The electronics has been designed by the Dzhelepov Laboratory of Nuclear Problems (JINR) and INFN (Torino, Italy) experts

  4. Light clay straw bale solutions in the contemporary housing as an element of sustainable development. Selected issues

    Directory of Open Access Journals (Sweden)

    Drozd Wojciech

    2016-01-01

    Full Text Available The article presents issues related to the solutions with light clay and straw bale in the contemporary housing. Building using straw bale and light clay is simple, eco-friendly and accessible to all. It fits in with the idea of sustainable development, supporting local businesses and giving people the opportunity to integrate in the design and construction of the house. The article presents the thermal analysis for both walls made of straw bale and of light clay. The analysis showed a very good performance. All positive aspects allow treating straw and light clay as a viable alternative to the commonly used technologies for erecting buildings.

  5. The impact of housing policies and housing markets on ethnic spatial segregation

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Andersson, Roger; Wessel, Terje

    2015-01-01

    This paper examines how ethnic segregation is connected to an ethnic division of the housing market and a spatial separation of different housing tenures in four Nordic cities. Explanations for the differences across the cities are found by comparing housing markets and housing policies....... The housing markets are in all four cities ethnically segmented with high concentrations of immigrants in some forms of tenures (especially social/public housing) and low concentrations in others. We further discuss the reasons for the observed pattern. The paper shows that the spatial distribution...... housing, while co-operative housing is crucial in the fourth. It is also shown that a policy of neighbourhood tenure mix in one of the cities has resulted in a relatively low degree of segregation in spite of high concentrations of immigrants in social/public housing....

  6. Plasma-wall interaction in NET

    International Nuclear Information System (INIS)

    Engelmann, F.; Chazalon, M.; Moons, F.; Vieider, G.; Harrison, M.F.A.; Hotston, E.S.

    1987-01-01

    NET is conceived as an experimental reactor with the aim of demonstrating reactor-relevant plasma performance and reliable operation of the device as well as developing and testing components for a demonstration reactor. For power and particle exhaust both a single-null and a double-null poloidal divertor configuration are under consideration. An intense modelling effort is undertaken to predict the heat load and erosion characteristics for these configurations. Under burn conditions, the divertor will operate in the high-recycling regime. The resulting heat loads on the divertor plates are predicted to be somewhat more demanding in the case of a single-null divertor. If one excludes working under conditions where a large part of the power is exhausted by radiation from the plasma edge, refractory metals (W, Mo) have to be used for the plasma-facing surface of the divertor plates, the radial heat and particle transport in the scrape-off layer must be large and the plasma density at the edge of the discharge must be high (n s ≅ 5x10 19 m -3 ). Erosion of a bare stainless steel first wall, under normal working conditions, appears to be within acceptable limits, but the use of graphite armouring is considered in order to avoid wall damage due to localized loads of highly energetic particles and to protect against disruption. Such a solution would also be consistent with the anticipated requirements during start-up. For both the first wall and the divertor plates various concepts are under consideration. Using replaceable tiles as plasma-facing components throughout appears attractive. (orig./GG)

  7. Housing Conditions Contribute to Underweight in Children: An Example From Rural Villages in Southeast Sulawesi, Indonesia

    Directory of Open Access Journals (Sweden)

    Tasnim Tasnim

    2017-09-01

    Full Text Available Objectives The prevalence of underweight in children under 5 years of age is anomalously high in Konawe District, Southeast Sulawesi Province, Indonesia. This state of affairs may be related to poor housing conditions, such as limited access to clean water, the absence of a sanitary latrine, and the use of poor housing materials. Therefore, this study aimed to examine the effect of housing conditions on underweight in under-5 children in Konawe District. Methods This study was conducted in 2013 in 5 health centres in Konawe District, Southeast Sulawesi Province, and used a case-control study design. The study recruited 400 under-5 children, including 100 of whom were cases and 300 of whom were age-matched controls (1:3. Cases were underweight children, while the controls were children with a normal nutritional status. The independent variables were the availability and types of water and latrine facilities and housing materials (roof, wall, and floor. The statistical analysis used Cox regression. Results A lack of water availability (odds ratio [OR], 5.0; 95% confidence interval [CI], 2.7 to 9.5; p<0.001, a lack of latrine availability in the home (OR, 2.5; 95% CI, 1.5 to 4.0; p<0.001, and poor-quality roofing materials (OR, 1.7; 95% CI, 1.1 to 2.7; p<0.02 significantly contributed to underweight in children. In contrast, the walls and the floors did not contribute to under-5 year children being underweight (p=0.09 and p=0.71, respectively. Conclusions Sanitation facilities and roofing were identified as important factors to address in order to improve children’s nutritional status. Children’s health status was directly impacted by food intake via their nutritional status.

  8. An electrically conducting first wall for the fusion engineering device-A (FED-A) tokamak

    International Nuclear Information System (INIS)

    Cramer, B.A.; Fuller, G.M.

    1983-01-01

    The first wall of the tokamak FED-A device was designed to satisfy two conflicting requirements. They are a low electrical resistance to give a long eddy-current decay time and a high neutron transparency to give a favorable tritium breeding ratio. The tradeoff between these conflicting requirements resulted in a copper alloy first wall that satisfied the specific goals for FED-A, i.e., a minimum eddy-current decay time of 0.5 sec and a tritium breeding ratio of at least 1.2. Aluminum alloys come close to meeting the requirements and would also probably work. Stainless steel will not work in this application because shells thin enough to satisfy temperature and stress limits are not thick enough to give a long eddy-current decay time and to avoid disruption induced melting. The baseline first wall design is a rib-stiffened, double-wall construction. The total wall thickness is 1.5 cm, including a water coolant thickness of 0.5 cm. The first wall is divided into twelve 30-degree sectors. Flange rings at the ends of each sector are bolted together to form the torus. Structural support is provided at the top center of each sector

  9. New methods for isolation of keratolytic bacteria inducing intractable hoof wall cavity (Gidoh) in a horse; double screening procedures of the horn powder agar-translucency test and horn zymography.

    Science.gov (United States)

    Kuwano, Atsutoshi; Niwa, Hidekazu; Arai, Katsuhiko

    2017-01-01

    To establish a new system to isolate keratolytic bacteria from the hoof wall cavity ( Gidoh ) of a racehorse, we invented the horn powder agar-translucency (HoPAT) test and horn zymography (HZ). Using routine bacteriological techniques and these methods, we isolated five strains of keratolytic soil bacteria, which were then identified by means of 16S ribosomal RNA (rRNA) gene sequencing analysis. The findings from the study on the horse suggested that Brevibacterium luteolum played the main role in the local fragility of the hoof, eventually forming a Gidoh in coordination with four other strains of keratolytic bacteria. The double screening procedures of the HoPAT test and HZ were useful and easy techniques for isolating the keratolytic bacteria from the horn lesions.

  10. Prize-winning energy conservation house equipped with air collectors at Bad Vilbel

    Energy Technology Data Exchange (ETDEWEB)

    Urbanek, A.

    An energy conservation house is the winner out of a total of 60 designs and is displayed at the prefabricated-house exhibition at Bad Vilbel. Similar to Socrates' building in antiquity, this house constitutes a triangle both perpendicularly and horizontally opening its largest possible surface to the South. Any 'residual heat' needed for the Northern roof planted over, is supplied by the air collectors either directly or by means of a high-performance heat pump via heating of the controlled feed air through a novel air floor heating installation while removing energy, too, from the exhaust air through heat recovery. In a survey supported by photos of models and buildings, lay-out plans and connector diagrams of energy supply, technical details of the heat protection concept (aerated concrete for walls, ceilings, roofing structures) and the energy concept with air collectors are described along with a discussion of heat pump operation, the novel air floor heating system and the solar cycle control system. Every room has a miniature heat exchanger allocated in the central unit so that re-heated air can be demanded via the separate room thermostat depending on reflow-air temperature.

  11. Quantum Interference Control of Ballistic Magneto- resistance in a Magnetic Nanowire Containing Two Atomic- Size Domain Walls

    Directory of Open Access Journals (Sweden)

    V. Fallahi

    2012-06-01

    Full Text Available The magnetoresistance of a one-dimensional electron gas in a metallic ferromagnetic nanowire containing two atomic-size domain walls has been investigated in the presence of spin-orbit interaction. The magnetoresistance is calculated in the ballistic regime, within the Landauer-Büttiker formalism. It has been demonstrated that the conductance of a magnetic nanowire with double domain walls can be controlled through the domain walls separation. Also, we have represented another alternative way that enables us to handle easily the magnetoresistance of such a system as well as its conductance by utilizing the Rashba-type spin-orbit interaction induced by the external gates.

  12. Some results from the demonstration of indoor radon reduction measures in block basement houses. Report for June 1985-February 1987

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1987-03-01

    The paper gives results of tests of active soil-ventilation techniques in 24 block-wall basement houses in eastern Pennsylvania having significantly elevated indoor radon concentrations, generally above 740 Bq/cu m. The results indicate that radon levels can be reduced substantially (often below the U.S. EPA guideline of 148 Bq/cu m) if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: (a) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or (b) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or soil underneath the slab

  13. Cold Climate Foundation Retrofit Energy Savings: The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, L. F.; Steigauf, B.

    2013-04-01

    A split simulation whole building energy/3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

  14. Cold Climate Foundation Retrofit Energy Savings. The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Steigauf, Brianna [NorthernSTAR Building America Partnership, Minneapolis, MN (United States)

    2013-04-01

    A split simulation whole building energy / 3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

  15. Understanding of Danish passive houses based on pilot project Comfort Houses

    Energy Technology Data Exchange (ETDEWEB)

    Brunsgaard, C.

    2010-12-15

    The aim of the research is to investigate the notion of passive houses in Denmark. When this PhD thesis was initiated, the Danish building industry has just started to become interested in the passive house concept, but the knowledge was very limited. To be able to speed up the process of constructing Danish passive houses or other low energy concepts Saint-Gobain Isover Scandinavia took the initiative to the pilot project of the Comfort Houses, ten single-family houses constructed as passive houses, and wanted to share the knowledge with the building industry and other interested. This PhD thesis was a part of the strategy. If the concept of passive houses should be successfully promoted and achieve a significant sale in Denmark, it is believed that it is necessary to do a holistic approach. Besides energy savings and new structural solutions more qualitative aspects like architecture, everyday life and the future ways of living needs to be integrated in the future understanding of passive houses. This Ph.D. thesis therefore studies the following research question: What can the experience from the Comfort Houses enlighten about the future production and use of Danish passive houses? This understanding is achieved through studies of different study fields to be able to create a more holistic understanding of the concept both covering qualitative and quantitative analysis. The main focus will be on the study fields Design Process, Architecture and Everyday Life and the Indoor environment, which will answer the following sub-research questions: 1) How has the consortiums behind the Comfort Houses approached the design process according to teamwork, method and tools? And what barriers and possibilities lie within the approaches? 2) How do the occupants of the Comfort Houses experience the passive house architecture and the technical service systems? And has their everyday life changed by moving into a passive house? If so, how? 3) To what extent do the Comfort Houses

  16. Modeling Enclosure Design in Above-Grade Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, J. [Building Science Corporation, Westford, MA (United States); Ueno, K. [Building Science Corporation, Westford, MA (United States); Musunuru, S. [Building Science Corporation, Westford, MA (United States)

    2016-03-01

    This report describes the modeling of typical wall assemblies that have performed well historically in various climate zones. The WUFI (Warme und Feuchte instationar) software (Version 5.3) model was used. A library of input data and results are provided. The provided information can be generalized for application to a broad population of houses, within the limits of existing experience. The WUFI software model was calibrated or tuned using wall assemblies with historically successful performance. The primary performance criteria or failure criteria establishing historic performance was moisture content of the exterior sheathing. The primary tuning parameters (simulation inputs) were airflow and specifying appropriate material properties. Rational hygric loads were established based on experience - specifically rain wetting and interior moisture (RH levels). The tuning parameters were limited or bounded by published data or experience. The WUFI templates provided with this report supply useful information resources to new or less-experienced users. The files present various custom settings that will help avoid results that will require overly conservative enclosure assemblies. Overall, better material data, consistent initial assumptions, and consistent inputs among practitioners will improve the quality of WUFI modeling, and improve the level of sophistication in the field.

  17. Family Open House

    Science.gov (United States)

    Search Family Open House Join us for an afternoon of science fun. The Fermilab Family Open House is a party for children of all ages to learn about the world of physics. The Open House is supported by Open House? Check out our YouTube video to learn more! Explore physics concepts with hands-on

  18. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  19. A NEW DOUBLE-SLIT CURVED WALL-JET (CWJ) BURNER FOR STABILIZING TURBULENT PREMIXED AND NON-PREMIXED FLAMES

    KAUST Repository

    Mansour, Morkous S.

    2015-06-30

    A novel double-slit curved wall-jet (CWJ) burner was proposed and employed, which utilizes the Coanda effect by supplying fuel and air as annular-inward jets over a curved surface. We investigated the stabilization characteristics and structure of methane/air, and propane/air turbulent premixed and non-premixed flames with varying global equivalence ratio, , and Reynolds number, Re. Simultaneous time-resolved measurements of particle image velocimetry and planar laser-induced fluorescence of OH radicals were conducted. The burner showed potential for stable operation for methane flames with relatively large fuel loading and overall rich conditions. These have a non-sooting nature. However, propane flames exhibit stable mode for a wider range of equivalence ratio and Re. Mixing characteristics in the cold flow of non-premixed cases were first examined using acetone fluorescence technique, indicating substantial transport between the fuel and air by exhibiting appreciable premixing conditions.PIV measurements revealed that velocity gradients in the shear layers at the boundaries of the annularjets generate the turbulence, enhanced with the collisions in the interaction jet, IJ,region. Turbulent mean and rms velocities were influenced significantly by Re and high rms turbulent velocities are generated within the recirculation zone improving the flame stabilization in this burner.Premixed and non-premixed flames with high equivalence ratio were found to be more resistant to local extinction and exhibited a more corrugated and folded nature, particularly at high Re. For flames with low equivalence ratio, the processes of local quenching at IJ region and of re-ignition within merged jet region maintained these flames further downstream particularly for non-premixed methane flame, revealing a strong intermittency.

  20. Housing First or no housing? Housing and homelessness at the end of alcohol and drug treatment.

    Science.gov (United States)

    Dyb, Evelyn

    2016-10-01

    The rate of alcohol and drug dependency is high among homeless persons in Norway as well as in other Western societies. National homeless surveys also show a certain correlation between discharge from institutions and homelessness. However, the rate of homelessness versus the rate with fixed abode at the end of specialised alcohol and drug treatment has not been examined using quantitative methods. A cross-sectional survey was conducted in alcohol and drug treatment units in the national health services and private clinics. The survey investigates the housing outcome at the end of treatment compared to the situation at the start of treatment using an individual questionnaire for patients ending treatment in a specific time window. Housing outcome is measured by the odds ratio of having a fixed abode at the end of treatment in relation to main intoxicating substance, type of treatment (in- and outpatient), completing versus cutting short the treatment, housing situation at the start of treatment, socioeconomic capital, mental health problems, individual plan, medical assisted treatment, and a set of background variables. The housing versus homeless situation hardly changes during the treatment period. In both a bivariate analysis and a simple multivariate model, principal intoxicating substance is the strongest predictor of having a fixed abode both before and after treatment. However, a more sophisticated analysis indicates that socioeconomic resources and social capital play along with the preferred intoxicating substance as predictors of having permanent housing. After more than a decade of a housing-led national homeless policy, and wide embracement of Housing First approaches in the European Union, homeless persons entering specialised alcohol and drug treatment are likely to return to the streets and hostels at the end of treatment. Access to housing after treatment is very limited for those lacking resources to solve their housing problem without assistance

  1. Symmetry Methods of Flow and Heat Transfer between Slowly Expanding or Contracting Walls

    Directory of Open Access Journals (Sweden)

    Gabriel Magalakwe

    2013-01-01

    Full Text Available An analysis has been carried out for the flow and heat transfer of an incompressible laminar and viscous fluid in a rectangular domain bounded by two moving porous walls which enable the fluid to enter or exit during successive expansions or contractions. The basic equations governing the flow are reduced to the ordinary differential equations using Lie-group analysis. Effects of the permeation Reynolds number , porosity , and the dimensionless wall dilation rate on the self-axial velocity are studied both analytically and numerically. The solutions are represented graphically. The analytical procedure is based on double perturbation in the permeation Reynolds number and the wall expansion ratio , whereas the numerical solution is obtained using Runge-Kutta method with shooting technique. Results are correlated and compared for some values of the physical parameters. Lastly, we look at the temperature distribution.

  2. Some features of a typical house as perceived by native speakers of English and of Serbian

    Directory of Open Access Journals (Sweden)

    Dilparić Branislava M.

    2015-01-01

    Full Text Available The paper reports findings from one of the two differently-designed surveys conducted among groups of both native speakers of English and native speakers of Serbian with a common general objective to obtain a picture of better candidates for a role of the whole (to be analyzed into its constituent elements in the contrastive study on the lexical field a house and its parts in English and Serbian. The specific objective of the survey presented here, however, was to build up the target picture with some of the features of the ideal example of the house category, such as the shape of the house, the key materials its principal structural elements (foundations, walls, a roof are made of, the number of residential units in the house and the type of the household that occupies it, the number of the house levels, the minimum of its interior spatial components and their functions, the types of systemic parts in the house, the status and position of the house relative to surround­ing buildings, etc. Also, taking into consideration that the demographic profiles of the survey participants reflected various cultural backgrounds (which significantly influence the formation of mental images of a typical sample of the category, the survey aimed to compare the similarities and differences between the 'English' and the 'Serbian' typical house, that is the features assigned to a typical house by most of the surveyed representa­tives of Anglo-American and by those of Serbian culture. Judging exclusively by the features observed and the results obtained, the study concludes that the 'English' and the 'Serbian' typical house look very similar in many aspect and that the two different cultures are not as distant as they may seem.

  3. Evaluation of wall thinning of piping with reinforcing plates using ECT with controlled exciting field

    International Nuclear Information System (INIS)

    Ichihara, Toshiaki; Xie, Shejuan; Uchimoto, Tetsuya; Takagi, Toshiyuki

    2011-01-01

    No effective inspection method exists at present for detection and evaluation of wall thinning under the reinforcing plates to T-tubes in nuclear power plants, and the establishment of the inspection method is highly required. In this study, eddy current testing (ECT) with controlled exciting field is applied to evaluation of wall thinning under the reinforcing plates of T-tubes, and their feasibility is discussed. In order to induce eddy current field in deep region of doubled plates, pulse excitation and probe structures are investigated. Through experiments using specimens simulating tubes with reinforcing plates, it is shown that pulsed ECT and conventional TR type eddy current probe with optimized configuration have a capability of detecting and sizing the wall thinning under reinforcing plates. (author)

  4. House Price, House Quality and Economic Growth

    NARCIS (Netherlands)

    De Vries, P.; Boelhouwer, P.J.

    2010-01-01

    The literature on housing markets suggest that periods of economic growth are characterised by a demand for better housing quality and increasing prices. The basic principles of the theory are that the short-run price fluctuations occur due to market imperfection, while over the long term, causality

  5. Double-yoke balanced compressor

    International Nuclear Information System (INIS)

    Durenec, P.

    1981-01-01

    A double-yoke balanced compressor for a cryogenic cooler that has only linear motion imparted to balanced piston and cylinder masses. A piston yoke is driven in the linear stroke direction by a piston axially offset crankshaft cam and a cylinder yoke is driven linearly by a cylinder axially offset crankshaft cam that is exactly offset 180 0 from the other cam. A large circular bushing in the compressor housing covers the entire outer cylinder head during linear operation to prevent blow by and to guide the cylinder linearly. The lower portion of the piston and cylinder connecting rods fit into linear guides that are further comprised of low molecular weight gas filled cavities to provide additional air bearing smoothness to the linear motion of the piston and cylinder

  6. Livable Housing Design: The voluntary provision of inclusive housing in Australia

    Directory of Open Access Journals (Sweden)

    Margaret Louise Ward

    2014-06-01

    Full Text Available This paper reports on a study of the voluntary provision of inclusive housing. The impetus for the study is the Livable Housing Design initiative, an agreement among Australian housing industry and community leaders in 2010 to a national guideline and voluntary strategy with a target to provide minimum access features in all new housing by 2020. Situated in and around Brisbane, Australia, the study problematises the assumption that the housing industry will respond voluntarily; an assumption which this study concludes is unfounded. The Livable Housing Design initiative asks individual agents to consider the needs of people beyond the initial contract, to proceed with objective reasoning and to do the right thing voluntarily. Instead, the study found that interviewees focused on their immediate contractual obligations, were reluctant to change established practices and saw little reason to do more than was legally required of them. This paper argues that the highly-competitive and risk-averse nature of the industry works against a voluntary approach for inclusive housing and, if the 2020 target of the Livable Housing Design.

  7. Tech House

    Science.gov (United States)

    1978-01-01

    The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, loatedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

  8. The Special Importance of Housing Policy for the Housing Situation of Ethnic Minorities

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Magnusson Turner, Lena; Søholt, Susanne

    The purpose of this article is to uncover, whether housing policy has a special importance for immigrants, compared with the whole population, by comparing housing policies and immigrants’ housing outcomes in four Nordic countries: Denmark, Finland, Norway and Sweden. There are substantial...... population varies much. These differences can only to some extent be explained by income inequalities on the housing markets in the countries, inequalities that affect immigrants. Other important explanations of why immigrants perform worse on the housing market is the shortage of rental housing (Norway......’ housing options are strict needs test for social/public housing (Finland)....

  9. The Special Importance of Housing Policy for the Housing Situation of Ethnic Minorities

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Turner, Lena Magnusson; Søholt, Susanne

    2013-01-01

    The purpose of this article is to uncover, whether housing policy has a special importance for immigrants, compared with the whole population, by comparing housing policies and immigrants’ housing outcomes in four Nordic countries: Denmark, Finland, Norway and Sweden. There are substantial...... population varies much. These differences can only to some extent be explained by income inequalities on the housing markets in the countries, inequalities that affect immigrants. Other important explanations of why immigrants perform worse on the housing market is the shortage of rental housing (Norway......’ housing options are strict needs test for social/public housing (Finland)....

  10. Electron beam emission and interaction of double-beam gyrotron

    International Nuclear Information System (INIS)

    Singh, Udaybir; Kumar, Anil; Kumar, Nitin; Kumar, Narendra; Pratap, Bhanu; Purohit, L.P.; Sinha, A.K.

    2012-01-01

    Highlights: ► The complete electrical design of electron gun and interaction structure of double-beam gyrotron. ► EGUN code is used for the simulation of electron gun of double-beam gyrotron. ► MAGIC code is used for the simulation of interaction structure of double-beam gyrotron. ► Design validations with other codes. - Abstract: This paper presents the numerical simulation of a double-beam magnetron injection gun (DB-MIG) and beam-wave interaction for 60 GHz, 500 kW gyrotron. The beam-wave interaction calculations, power and frequency growth estimation are performed by using PIC code MAGIC. The maximum output power of 510 kW at 41.5% efficiency, beam currents of 6 A and 12 A, electron beam velocity ratios of 1.41 and 1.25 and beam voltage of 69 kV are estimated. To obtain the design parameters, the DB-MIG with maximum transverse velocity spread less than 5% is designed. The computer simulations are performed by using the commercially available code EGUN and the in-house developed code MIGANS. The simulated results of DB-MIG design obtained by using the EGUN code are also validated with another trajectory code TRAK, which are in good agreement.

  11. Electron beam emission and interaction of double-beam gyrotron

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Udaybir, E-mail: uday.ceeri@gmail.com [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute (CEERI), Council of Scientific and Industrial Research (CSIR), Pilani, Rajasthan 333031 (India); Department of Physics, Gurukul Kangri University, Haridwar 249404 (India); Kumar, Anil [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute (CEERI), Council of Scientific and Industrial Research (CSIR), Pilani, Rajasthan 333031 (India); Kumar, Nitin, E-mail: nitin_physika@rediffmail.com [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute (CEERI), Council of Scientific and Industrial Research (CSIR), Pilani, Rajasthan 333031 (India); Kumar, Narendra; Pratap, Bhanu [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute (CEERI), Council of Scientific and Industrial Research (CSIR), Pilani, Rajasthan 333031 (India); Purohit, L.P. [Department of Physics, Gurukul Kangri University, Haridwar 249404 (India); Sinha, A.K., E-mail: aksinha@ceeri.ernet.in [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute (CEERI), Council of Scientific and Industrial Research (CSIR), Pilani, Rajasthan 333031 (India)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer The complete electrical design of electron gun and interaction structure of double-beam gyrotron. Black-Right-Pointing-Pointer EGUN code is used for the simulation of electron gun of double-beam gyrotron. Black-Right-Pointing-Pointer MAGIC code is used for the simulation of interaction structure of double-beam gyrotron. Black-Right-Pointing-Pointer Design validations with other codes. - Abstract: This paper presents the numerical simulation of a double-beam magnetron injection gun (DB-MIG) and beam-wave interaction for 60 GHz, 500 kW gyrotron. The beam-wave interaction calculations, power and frequency growth estimation are performed by using PIC code MAGIC. The maximum output power of 510 kW at 41.5% efficiency, beam currents of 6 A and 12 A, electron beam velocity ratios of 1.41 and 1.25 and beam voltage of 69 kV are estimated. To obtain the design parameters, the DB-MIG with maximum transverse velocity spread less than 5% is designed. The computer simulations are performed by using the commercially available code EGUN and the in-house developed code MIGANS. The simulated results of DB-MIG design obtained by using the EGUN code are also validated with another trajectory code TRAK, which are in good agreement.

  12. Counter-ions at single charged wall: Sum rules.

    Science.gov (United States)

    Samaj, Ladislav

    2013-09-01

    For inhomogeneous classical Coulomb fluids in thermal equilibrium, like the jellium or the two-component Coulomb gas, there exists a variety of exact sum rules which relate the particle one-body and two-body densities. The necessary condition for these sum rules is that the Coulomb fluid possesses good screening properties, i.e. the particle correlation functions or the averaged charge inhomogeneity, say close to a wall, exhibit a short-range (usually exponential) decay. In this work, we study equilibrium statistical mechanics of an electric double layer with counter-ions only, i.e. a globally neutral system of equally charged point-like particles in the vicinity of a plain hard wall carrying a fixed uniform surface charge density of opposite sign. At large distances from the wall, the one-body and two-body counter-ion densities go to zero slowly according to the inverse-power law. In spite of the absence of screening, all known sum rules are shown to hold for two exactly solvable cases of the present system: in the weak-coupling Poisson-Boltzmann limit (in any spatial dimension larger than one) and at a special free-fermion coupling constant in two dimensions. This fact indicates an extended validity of the sum rules and provides a consistency check for reasonable theoretical approaches.

  13. Exploring the Housing Needs of Older People in Standard and Sheltered Social Housing.

    Science.gov (United States)

    Fox, Siobhan; Kenny, Lorna; Day, Mary Rose; O'Connell, Cathal; Finnerty, Joe; Timmons, Suzanne

    2017-01-01

    Objective: Our home can have a major impact on our physical and mental health; this is particularly true for older people who may spend more time at home. Older people in social (i.e., public) housing are particularly vulnerable. Housing options for older people in social housing include standard design dwellings or specially designed "sheltered housing." The most suitable housing model should be identified, with older people consulted in this process. Method: Survey of older people (aged ≥60) living in standard or sheltered social housing. Data were analyzed using descriptive and inferential statistics in SPSS Version 22. Results: Overall, 380 surveys were returned (response rate = 47.2%). All older people had similar housing needs. Those in sheltered housing were more satisfied with the physical home design and reported more positive outcomes. Older people in standard housing were less likely to have necessary adaptations to facilitate aging-in-place. Discussion: Older people in standard housing reported more disability/illnesses, are worried about the future, and felt less safe at home. However, few wanted to move, and very few viewed sheltered housing as an alternative, suggesting limited knowledge about their housing options. Future social housing designs should be flexible, that is, adaptable to the needs of the tenants over time.

  14. Plasma-wall impurity experiments in ISX-A

    International Nuclear Information System (INIS)

    Colchin, R.J.; Bush, C.E.; Edmonds, P.H.; England, A.; Hill, K.W.; Isler, R.C.; Jernigan, T.C.; King, P.W.; Langley, R.A.; McNeill, D.H.; Murakami, M.; Neidigh, R.V.; Neilson, C.H.; Simpkins, J.E.; Wilgen, J.; DeBoo, J.C.; Burrell, K.H.; Ensberg, E.S.

    1978-01-01

    The ISX-A was a tokamak designed for studying plasma-wall interactions and plasma impurities. It fulfilled this role quite well, producing reliable and reproducible plasmas which had currents up to 175 kA and energy containment times up to 30 ms. With discharge precleaning, Zsub(eff) was as low as 1.6; with titanium evaporation. Zsub(eff) approached 1.0. Values of Zsub(eff) > approximately 2.0 were found to be proportional to residual impurity gases in the vacuum system immidiately following a discharge. However, there was no clear dependence of Zsub(eff) on base pressure. Stainless steel limiters were used in most of the ISX-A experiments. Upon introducing carbon limiters into the vacuum system, Zsub(eff) increased to 5.6. After twelve days of clean-up with tokamak discharges, during which time Zsub(eff) steadily decreased, the carbon limiters tended to give slightly higher values of Zsub(eff) than stainless steel limiters. Injection of 16 atoms of tungsten into discharges caused the power incident on the wall to double and the electron temperature profile to become hollow. (Auth.)

  15. Double-lock technique: a simple method to secure abdominal wall closure

    International Nuclear Information System (INIS)

    Jategaonkar, P.A.; Yadav, S.P.

    2013-01-01

    Secure closure of a laparotomy incision remains an important aspect of any abdominal operation with the aim to avoid the postoperative morbidity and hasten the patient's recovery. Depending on the operator's preference and experience, it may be done by the continuous or the interrupted methods either using a non-absorbable or delayed-absorbable suture. We describe a simple, secure and quick technique of abdominal wall closure which involves continuous suture inter-locked doubly after every third bite. This simple and easy to use mass closure technique can be easily mastered by any member of the surgical team and does not need any assistant. It amalgamates the advantages of both, the continuous and the interrupted methods of closures. To our knowledge, such a technique has not been reported in the literature. (author)

  16. Environmental Impacts and Embodied Energy of Construction Methods and Materials in Low-Income Tropical Housing

    Directory of Open Access Journals (Sweden)

    Arman Hashemi

    2015-06-01

    Full Text Available This paper evaluates the current conditions of Ugandan low-income tropical housing with a focus on construction methods and materials in order to identify the key areas for improvement. Literature review, site visits and photographic surveys are carried out to collect relevant information on prevailing construction methods/materials and on their environmental impacts in rural areas. Low quality, high waste, and energy intensive production methods, as well as excessive soil extraction and deforestation, are identified as the main environmental damage of the current construction methods and materials. The embodied energy is highlighted as the key area which should be addressed to reduce the CO2 emissions of low-income tropical housing. The results indicate that the embodied energy of fired bricks in Uganda is up to 5.7 times more than general clay bricks. Concrete walling is identified as a much more environmentally friendly construction method compared to brick walling in East African countries. Improving fuel efficiency and moulding systems, increasing access to renewable energy sources, raising public awareness, educating local manufacturers and artisans, and gradual long-term introduction of innovative construction methods and materials which are adapted to local needs and conditions are some of the recommended actions to improve the current conditions.

  17. Life changes among homeless persons with mental illness: a longitudinal study of housing first and usual treatment.

    Science.gov (United States)

    Nelson, Geoffrey; Patterson, Michelle; Kirst, Maritt; Macnaughton, Eric; Isaak, Corinne A; Nolin, Danielle; McAll, Christopher; Stergiopoulos, Vicky; Townley, Greg; MacLeod, Timothy; Piat, Myra; Goering, Paula N

    2015-06-01

    This study compared the life changes of homeless people with mental illness participating in Housing First or treatment as usual and examined factors related to various changes. Semistructured narrative interviews were conducted with 219 participants in five Canadian cities at baseline; 197 were interviewed again at 18 months after random assignment to Housing First (N=119) or treatment as usual (N=78). Interviews were coded across 13 life domains, and each participant was categorized as reporting positive, mixed-neutral, or negative changes. Housing First and treatment as usual participants were compared with respect to change patterns. Thematic analysis was used to examine factors related to various changes. The percentage of participants in Housing First reporting positive changes was more than double that for participants in treatment as usual, and treatment as usual participants were four times more likely than Housing First participants to report negative changes. Factors related to positive changes included having stable good-quality housing, increased control over substance use, positive relationships and social support, and valued social roles. Factors related to negative changes included precarious housing, negative social contacts, isolation, heavy substance use, and hopelessness. Factors related to mixed-neutral changes were similar to those for participants reporting negative changes but were less intense. Housing First with intensive support was related to more positive changes among homeless adults with mental illness across five Canadian cities. Those with poor housing or support, more common in treatment as usual, continued to struggle. These findings are relevant for services and social change to benefit this population.

  18. Radon and radon progeny in 70 houses in the Tennessee Valley area: study design and measurement methods

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.; Monar, K.P.; Quillen, J.L.; Clark, C. Jr.; Doane, R.W.; Wallace, R.G.; Reed, R.P.

    1986-01-01

    Levels of radon and its short-lived airborne progeny are being measured in a year-long study of 70 houses in four states in the Tennessee Valley. Various methods were used to solicit volunteers with differing degrees of success. Criteria for selection of houses in the study included presence of a lower level with cement floor and one or more block walls in contact with the soil, absence of obvious indications of technologically enhanced sources of radium, and proximity to one of four cities, (Knoxville, Chattanooga, Birmingham, or Florence). By design, most houses in the study are in the same neighborhood as at least one other house in the study. Houses range in age from newly constructed to about 40 years old. Most of the houses have more than 2000 square feet of finished floor space. The lower level encompasses a garage in most cases. More complete information pertaining to house characteristics will be gathered in the course of the study. Measurements are being made to obtain information on both location- and season-dependent variation of radon and radon progeny. Simultaneous measurements are made quarterly on both upper and lower levels of each house. Grab samples of air are collected and analyzed for radon using a modified Lucas cell technique. Short-term (10-minute) samples of airborne particulate material are collected and analyzed for radon progeny. One-week integrated measurements of working levels are made once each quarter using modified thermoluminescent dosimeters. Both three- and twelve-month integrated measurements of radon using track-etch monitors are being made. 19 references, 1 figures

  19. A low walk double threshold discriminator for gas tracking devices

    International Nuclear Information System (INIS)

    Balla, A.; Benussi, L.; Bertani, M.; Bianco, S.; Corradi, G.; Fabbri, F. L.; Giannotti, P.; Giardoni, M.; Lucherini, V.; Pace, E.; Passamonti, L.; Pompili, F.; Russo, V.; Sarwar, S.; Tomassini, S.

    2001-01-01

    A 9U VME like double threshold discriminator has been designed and constructed at Frascati INFN (National Institute of Nuclear Physics) laboratories. Its aim is to process the signals arising from gas drift chambers, introducing a very small time walk (∼ 650 ps.). Each discriminator board houses 32 channels. Each channel is located on an independent printed circuit mounted on socket. This solution is very convenient for replacing faulty channels without loosing operation of the full board

  20. Have Housing Prices Gone with the Smelly Wind? Big Data Analysis on Landfill in Hong Kong

    Directory of Open Access Journals (Sweden)

    Rita Yi Man Li

    2018-01-01

    Full Text Available Unlike many other places around the globe, Hong Kong is a small city with a high population density. Some housing units are built near the sources of an externality, such as a landfill site. As the blocks of buildings are particularly tall, many are walled buildings that block the bad odor from the landfill. Thus, the wind blowing from a landfill site may not affect the entire building estate. Some buildings are more heavily affected than others, partly because walled buildings built near landfills are rare. Only a few studies currently examine the correlation between wind direction and the prices of walled buildings. In this paper, we aim to bridge this research gap by illustrating Hong Kong as a case study. Most previous research studies only examine a few factors affecting housing prices. Modern big data is characterized by its large volume of data, which includes various types of data that analysts would not necessarily sample, but instead merely observe to track what happens. Therefore, another innovative point of our paper, is that we adopt a big data approach to study this issue. In this aspect, this paper is the first of its kind. There are 53,071 observations in the 1999 to 2014 dataset, with 2,175,911 data entries. Our results reflect that when more municipal solid waste is sent to the South East New Territories Landfill, residents’ complaints in Tseung Kwan O increase. However, entire property prices in the region also increase, which rejects our hypothesis. We speculate that as more people become aware of the housing estate due to complaints, with only a limited number of housing units affected by the smell, since the wind usually only blows in certain directions, the “advertisement effect” originating from complaints about the bad smell boosts the property prices of the unaffected units. That is, people become aware of the existence of the property, visit the site, and discover that only specific units facing one particular

  1. The MAJORANA experiment: an ultra-low background search for neutrinoless double-beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, D.; Aguayo Navarrete, Estanislao; Avignone, Frank T.; Back, Henning O.; Barabash, Alexander S.; Bergevin, M.; Bertrand, F.; Boswell, M.; Brudanin, V.; Busch, Matthew; Chan, Yuen-Dat; Christofferson, Cabot-Ann; Collar, J. I.; Combs, Dustin C.; Cooper, R. J.; Detwiler, Jason A.; Doe, Peter J.; Efremenko, Yuri; Egorov, Viatcheslav; Ejiri, H.; Elliott, Steven R.; Esterline, James H.; Fast, James E.; Fields, N.; Finnerty, P.; Fraenkle, Florian; Gehman, Victor; Giovanetti, G. K.; Green, Matthew P.; Guiseppe, Vincente; Gusey, K.; Hallin, A. L.; Hazama, R.; Henning, Reyco; Hime, Andrew; Hoppe, Eric W.; Horton, Mark; Howard, Stanley; Howe, M. A.; Johnson, R. A.; Keeter, K.; Keller, C.; Kidd, Mary; Knecht, A.; Kochetov, Oleg; Konovalov, S.; Kouzes, Richard T.; LaFerriere, Brian D.; LaRoque, B. H.; Leon, Jonathan D.; Leviner, L.; Loach, J. C.; MacMullin, S.; Marino, Michael G.; Martin, R. D.; Mei, Dong-Ming; Merriman, Jason H.; Miller, M. L.; Mizouni, Leila; Nomachi, Masaharu; Orrell, John L.; Overman, Nicole R.; Poon, Alan; Perumpilly, Gopakumar; Prior, Gersende; Radford, D. C.; Rielage, Keith; Robertson, R. G. H.; Ronquest, M. C.; Schubert, Alexis G.; Shima, T.; Shirchenko, M.; Snavely, Kyle J.; Steele, David; Strain, J.; Thomas, K.; Timkin, V.; Tornow, W.; Vanyushin, I.; Varner, R. L.; Vetter, Kai; Vorren, Kris R.; Wilkerson, J. F.; Wolfe, B. A.; Yakushev, E.; Young, A.; Yu, Chang-Hong; Yumatov, Vladimir; Zhang, C.

    2012-12-01

    The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana Experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to validate whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.

  2. Henryk Uziębło's heraldic decoration in the chapter house in Wawel

    Directory of Open Access Journals (Sweden)

    Józef Marecki

    1998-12-01

    Full Text Available Henryk Uziembło (27 February 1879 – 3 May 1945 was one of the creators of modern decorative art; he also made graphics. From 1922 to the outbreak of World War II he was a lecturer at the Institute of Fine Arts in Krakow. He designed polychromes, stained glass windows and mosaics, book bindings, posters and made oil paintings. He is the author of the decorations of the wall of the Wawel chapter house.

  3. DOE ZERH Case Study: Hammer and Hand, Pumpkin Ridge Passive House, North Plains, OR

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got a HERS 49 without PV, or HERS 5 with PV, with 2x4 24” on center walls plus 8” exterior cavity together dense-packed with R-60 cellulose; daylight basement with R-29 rigid EPS foam under slab; vented attic with R-86 blown cellulose; minisplit heat pump; ducted with HRV; 15.5 SEER; 10 HSPF.

  4. Essays on Housing Markets

    DEFF Research Database (Denmark)

    Bäckman, Claes

    In Denmark and in many countries around the world, housing markets are of considerable importance for households and policy-makers alike. As the boom and bust in the US and Danish housing market so aptly demonstrated, disruptions in the housing market potentially have wide-ranging consequences...... for individual households and for the aggregate economy. Housing is important because we all have to live somewhere, but also because it serves as a considerable source of both wealth and debt. As such, housing market policy can not only create vast benefits for many, but can also have substantial negative...... impacts for all, and should therefore be a topic of major interest for economists and policy makers alike. This Ph.D. thesis, entitled “Essays on Housing Markets”, analyzes the Danish housing market during the 2000s, with a focus on how policy changes affected house prices and how changes in house prices...

  5. The bishops and housing.

    Science.gov (United States)

    Shellabarger, Thomas

    2005-01-01

    According to Catholic social teaching, housing is not a commodity but a human right. To ensure that all people--especially low-income elderly and other vulnerable populations--have access to affordable housing, the church has established a variety of programs, services, and advocacy efforts. Much of this work is based on key concepts: preserving existing housing stock, creating new programs to provide more options for the underserved, empowering residents and communities to deal with housing issues, establishing partnerships to make organizations' efforts more successful, making housing affordable, and ending discrimination in housing. Although church ministries, community groups, the private sector, and other players must work together to find solutions to the housing crisis, federal leadership is essential. Especially with the housing affordability gap growing and the U.S. population aging, the federal government must provide the resources, leadership, and direction for effective housing solutions.

  6. Pancreatic Necrosectomy Through a Novel Double-flange Lumen-apposing Covered Metal Stent (Video

    Directory of Open Access Journals (Sweden)

    Andres Sanchez-Yague

    2014-12-01

    A double flange lumen apposing FC-SEMS used as a port for necrosectomy significantly improves management of walled-off pancreatic necrosis. Placement of this stents should be considered when multiple necrosectomy sessions are anticipated. Procedure time can be significantly decreased using a catheter that combines a cautery tip and stent delivery system.

  7. Radon in houses

    International Nuclear Information System (INIS)

    Toohey, R.E.; Essling, M.A.; Markun, F.

    1985-01-01

    The purpose of this study is to determine the concentrations of 222 Rn and its short-lived daughter products in the air of single-family houses in the midwestern US. During the past year, more than 200 houses were added to the study, resulting in a total of more than 400 houses. So far, results are available for 270 of these houses, equally divided between the Chicago area and Bloomsburg, Pennsylvania. 6 refs

  8. Description of case houses. Building integrated energy supply; Beskrivelse af casehuse. Bygningsintegreret energiforsyning

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Rasmus L.; Noergaard, J.; Daniels, O.; Justesen, R.O.

    2011-08-15

    In the future, buildings will not only act as consumers of energy but as producers as well. For these ''prosumers'', energy production by use of solar panels, photovoltaics and heat pumps etc will be essential. The objective of this project was to find the most optimal combinations of building insulation and use of renewable energy sources in existing buildings in terms of economics and climate impacts. Five houses were analyzed based on different personal load, consumption profiles, solar orientation and proposed building envelope improvements and use of combinations of renewable energy systems. The present report describes typical construction details of the building envelope (windows, floor, outside wall and roof/ceiling) for houses built in the years 1961-1972, 1973-1978 and 1979-1998. Furthermore the report describes the necessary improvements for the buildings' U-value to be the minimum value as stated in the Danish building code of 2010, and to be the values for buildings at the level of low-energy class 2015. Cost estimation for optimizing the houses to an optimum insulation level has been made. (ln)

  9. Energy conservation and recycling of wall and concrete may give large environmental profits in the construction industry. Environment taken seriously

    International Nuclear Information System (INIS)

    Nestvold, Veslemoey

    2000-01-01

    The article reviews some results from the 5 year project ''Oekobygg'', started in 1998, which studies energy conservation and recycling of wall and concrete in the construction industry. Reduction of the waste amounts, industrial recycling and ''smart housing'' are discussed. Recycling will result in the largest environmental benefits

  10. Trombe wall and glazings facades: Energy efficiency for different Portuguese Climates

    Directory of Open Access Journals (Sweden)

    Sacht, H. M.

    2013-09-01

    Full Text Available High performance glass and Trombe walls in the façade was studied in this research. The paper reports results of an ongoing investigation on a new façade system concept, designed as: “Façade Modules for Eco-Efficient Refurbishment of Buildings”, especially on energy efficiency of Trombe wall and glazing modules arrangement. Computational simulation was carried out by using the software DesignBuilder. Two double glazing types and Trombe walls were considered for three different climates in Portugal and four solar orientations. Results obtained for heating energy needs were compared to all façade configurations. The use of Trombe wall and the double self-cleaning glass in the façade point towards a significant decrease of heating energy needs. The great majority of the façades combinations presented energy needs lower than the maximum allowed by the Portuguese regulation (RCCTE.Esta investigación aborda el estudio de fachadas con cristales de altas prestaciones y muros Trombe. El artículo presenta los resultados de la investigación en curso sobre un nuevo concepto en sistemas de fachada, denominado "Módulos de fachada para el acondicionamiento ecoeficiente de edificios", especialmente enfocado a la eficiencia energética de muros Trombe y módulos con doble acristalamiento. Haciendo uso del software DesignBuilder se realizaron simulaciones de una estancia, analizando distintos conjuntos de fachadas modulares. Para la realización de las simulaciones se consideraron dos tipos de módulos de doble acristalamiento, dos configuraciones de muros Trombe, tres climas diferentes en Portugal y cuatro orientaciones solares. Se compararon los requerimientos de calefacción de cada una de las configuraciones, observándose que tanto los muros Trombe como los módulos de doble acristalamiento presentaron disminuciones significativas en cuanto a requerimientos de calefacción. De las configuraciones analizadas, la mayoría presentó demandas energ

  11. Moisture effect on thermal conductivity of some major elements of a typical Libyan house envelope

    International Nuclear Information System (INIS)

    Suleiman, Bashir M

    2006-01-01

    The thermal conductivity and the assessment of moisture effect on building materials are essential for the calculation of the thermal loads on houses. Building materials such as simple units e.g. bricks, tiles, cement plasters, mortar and ground soils are investigated in this work. In the eastern coastal province of Libya, old buildings have thick walls (more than 50 cm thick made of mixed clay and stones) and consequently have good capacitive insulation. On the other hand, the relatively new houses have thin walls and need the addition of insulating materials. Unfortunately, these new houses were constructed without having enough technical data on the thermal properties of building materials and thermal loads were not considered. This leads to uncomfortable living conditions during hot and humid summers and cold and wet winters. This article reports the thermal conductivity values of three types of locally produced building materials used in the construction of a typical Libyan house envelope and gives suggestions to improve the thermal performance of such envelopes. The transient plane source technique (TPS) is used to measure the thermal conductivity of these materials at an average room temperature of 25 deg. C. The TPS technique uses a resistive heater pattern (TPS element) that is cut from a thin sheet of metal and covered on both sides with thin layers of an insulating material. The TPS element/sensor is used both as a heat source and as a temperature sensor. This technique has the dual advantage of short measuring time and low temperature rise (around 1 K) across the sample. This will prevent a non-uniform moisture distribution that may arise when the temperature difference across the wet samples is maintained for a long time. In addition, the flat thin shape of the TPS element substantially reduces the contact resistance between the sample and the sensor. More details about the TPS technique are included

  12. Numerical simulation of double-pipe condensers and evaporators

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Valladares, O. [Universidad Nacional Autonoma de Mexico, Morelos (Mexico). Centro de Investigacion en Energia; Perez-Segarra, C.D.; Rigola, J. [Universitat Politecnica de Catalunya, Terrassa (Spain). Centre Tecnologic de Transferencia de Calor, Lab. de Termotecnia i Energetica

    2004-09-01

    A detailed one-dimensional steady and transient numerical simulation of the thermal and fluid-dynamic behaviour of double-pipe heat exchangers (evaporators and condensers) has been carried out. The governing equations (continuity, momentum and energy) inside the internal tube and the annulus, together with the energy equation in the internal tube wall, external tube wall and insulation, are solved iteratively in a segregated manner. The discretized governing equations in the zones with fluid flow are efficiently coupled using an implicit step by step method. This formulation requires the use of empirical correlations for the evaluation of convective heat transfer, shear stress and void fraction. An implicit central difference numerical scheme and a line-by-line solver was used in the internal and external tube walls and insulation. A special treatment has been implemented in order to consider transitions (single-phase/two-phase, dry-out,...). All the flow variables (enthalpies, temperatures, pressures, mass fractions, velocities, heat fluxes,...) together with the thermophysical properties are evaluated at each point of the grid in which the domain is discretized. Different numerical aspects and comparisons with analytical and experimental results are presented in order to verify and validate the model. (author)

  13. Housing preferences of young adults in Indonesia: housing attributes and consequences

    Science.gov (United States)

    Farasa, N.; Kusuma, H. E.

    2018-03-01

    Nowadays, the housing demand of young adults in Indonesia is important issues for the sustainable development of the market. Facing differences of life phases, such as marriage, leaving home after graduation, and new job positioning, young adults become the main segment facing constant housing choice decisions in the housing market. In their particular phase of life, young adults have distinct preferences for housing attributes which bring a great influence on their lives in the future. Data was gathered from a survey questionnaire that was answered by 180 young adults in Indonesia, ranging from age 22-33 years. The findings suggest that the green area and view, location, simplicity, home design, and accessibility are the significant parts as housing attributes for young adults’ housing preferences in Indonesia. The effect of these attributes has many consequences such as security, personalization, mood/ambiance, maintenance, interaction, image, flexibility, environmental, economy, durability, convenience, comfort, and circulation. The biggest group of young adults who prefer comfort as their wanted consequences tend to have high preferences on housing attributes of the green area and view, and simplicity.

  14. Time management in a co-housed social rodent species (Arvicanthis niloticus).

    Science.gov (United States)

    Castillo-Ruiz, Alexandra; Indic, Premananda; Schwartz, William J

    2018-01-19

    Sociality has beneficial effects on fitness, and timing the activities of animals may be critical. Social cues could influence daily rhythmic activities via direct effects on the circadian clock or on processes that bypass it (masking), but these possibilities remain incompletely addressed. We investigated the effects of social cues on the circadian body temperature (Tb) rhythms in pairs of co-housed and isolated grass rats, Arvicanthis niloticus (a social species), in constant darkness (DD). Cohabitation did not induce synchronization of circadian Tb rhythms. However, socio-sexual history did affect circadian properties: accelerating the clock in sexually experienced males and females in DD and advancing rhythm phase in the females in a light-dark cycle. To address whether synchronization occurs at an ultradian scale, we analyzed Tb and activity rhythms in pairs of co-housed sisters or couples in DD. Regardless of pair type, co-housing doubled the percentage of time individuals were simultaneously active without increasing individual activity levels, suggesting that activity bouts were synchronized by redistribution over 24 h. Together, our laboratory findings show that social cues affect individual "time allocation" budgets via mechanisms at multiple levels of biological organization. We speculate that in natural settings these effects could be adaptive, especially for group-living animals.

  15. CONSTRUCTION TECHNOLOGY OF UKRAINIAN NATIONAL HOUSING (PRYDNIPROVSK REGION IS AS AN EXAMPLE

    Directory of Open Access Journals (Sweden)

    EYVSEYEVA G. P.

    2016-03-01

    Building (with 20 figures into text. F.S. Dudko also describes in detail tehnology of ukrainian peasant houses construction as the safetiest and the cleanest houses of present. In the 70th of the XX century, works began to appear devoted to the study of nation architecture in Ukraine. The features of construction of one or another region, the types of peasant houses, their interior; construction of farm buildings, equipping of the yard were considered in this work. Among them A. Danyluk "Closed yards in Polesie" [6-7], A. Danyluk and M. Shpak "Traditional and new in boikivskyi housing construction" [8], M. Strunka "Ukrainian national housing of Mykolaivshchina" [16], M. Manurevich “Gagauz nation housing…”[14], Z. Petrova "Rural houses in the Carpathians" [15] and others [11; 13]. The purpose and the main directions of our research is to study the complex technology of the walls construction of the Ukrainians’national housing of Middle and Lower Naddniprianshchyny of Ukraine (of Prydniprovsk region of the end of XIX and middle of the XX century, as the Dnipropetrovsk region belongs to this historical and geographical, industrial and economic region.

  16. Correlation between vortices and wall shear stress in a curved artery model under pulsatile flow conditions

    Science.gov (United States)

    Cox, Christopher; Plesniak, Michael W.

    2017-11-01

    One of the most physiologically relevant factors within the cardiovascular system is the wall shear stress. The wall shear stress affects endothelial cells via mechanotransduction and atherosclerotic regions are strongly correlated with curvature and branching in the human vasculature, where the shear stress is both oscillatory and multidirectional. Also, the combined effect of curvature and pulsatility in cardiovascular flows produces unsteady vortices. In this work, our goal is to assess the correlation between multiple vortex pairs and wall shear stress. To accomplish this, we use an in-house high-order flux reconstruction Navier-Stokes solver to simulate pulsatile flow of a Newtonian blood-analog fluid through a rigid 180° curved artery model. We use a physiologically relevant flow rate and generate results using both fully developed and uniform entrance conditions, the latter motivated by the fact that flow upstream to a curved artery may not be fully developed. Under these two inflow conditions, we characterize the evolution of various vortex pairs and their subsequent effect on several wall shear stress metrics. Supported by GW Center for Biomimetics and Bioinspired Engineering.

  17. Relevance of NET first wall concept for DEMO DN

    International Nuclear Information System (INIS)

    Kiltie, J.S.

    1987-01-01

    Design studies for the Next European Torus (NET) have produced a design concept for the first wall. This concept features poloidal water cooling, double contained in a welded steel structure which is protected by radiatively cooled tiles. In this appendix the relevance of this concept to a DEMO is examined with particular emphasis given to the ability of the cooling tube arrangement to remove the heat. A suggested modification to the arrangement of coolant tubes is suggested so that the design can operate at the higher loadings of a DEMO. (author)

  18. Housing of Hobson's Choice

    DEFF Research Database (Denmark)

    Vestergaard, Hedvig

    2010-01-01

    This paper looks at policies implemented to improve troubled housing estates during more than two decades. Based on evaluations of implemented programmes and case studies the paper provides a basis for discussing a number of questions: • Why do we have troubled housing estates? • What...... is the definition of troubled housing estates? • Who lives on troubled housing estates? • Who owns and manages the troubled housing estates? • What have been the reasons behind improvement programmes for troubled housing estates? • What kind of improvement programmes have been implemented and with what kind...... of results? • Have improvement programmes changed the position of the estates on the local housing markets? • What are the changes in policies and results? • What are the perspectives for policy initiatives in the field of troubled housing estates?...

  19. Comparison between ARIMA and DES Methods of Forecasting Population for Housing Demand in Johor

    OpenAIRE

    Alias Ahmad Rizal; Zainun Noor Yasmin; Abdul Rahman Ismail

    2016-01-01

    Forecasting accuracy is a primary criterion in selecting appropriate method of prediction. Even though there are various methods of forecasting however not all of these methods are able to predict with good accuracy. This paper presents an evaluation of two methods of population forecasting for housing demand. These methods are Autoregressive Integrated Moving Average (ARIMA) and Double Exponential Smoothing (DES). Both of the methods are principally adopting univariate time series analysis w...

  20. Final results of double-shell tank 241-AZ-101 ultrasonic inspection

    International Nuclear Information System (INIS)

    JENSEN, C.E.

    1999-01-01

    This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AZ-101. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AZ-101 primary tank wall and welds. The inspection found one reportable indication of thinning and no reportable pitting, corrosion, or cracking

  1. Social and health outcomes following upgrades to a national housing standard: a multilevel analysis of a five-wave repeated cross-sectional survey.

    Science.gov (United States)

    Poortinga, Wouter; Jones, Nikki; Lannon, Simon; Jenkins, Huw

    2017-12-02

    While existing research indicates that housing improvements are associated with health improvements, less is known about the wider social and health benefits of meeting national housing standards, as well as those of their specific constituent measures. This study evaluates the impacts of a managed housing upgrade programme through a repeated cross-sectional survey design. A five-wave repeated cross-sectional survey was conducted over a seven-year period from 2009 to 2016 (n = 2075; n = 2219; n = 2015; n = 1991; and n = 1709, respectively). The study followed a managed upgrade programme designed to meet a national social housing standard over an extended period. The data were analysed from a multilevel perspective to take account of the time-dependent nature of the observations and differences in socio-demographic composition. The installation of the majority of individual housing measures (new windows and doors; boilers; kitchens; bathrooms; electrics; loft insulation; and cavity/external wall insulation) were associated with improvements in several social (housing suitability, satisfaction, and quality; thermal comfort and household finances) and health (mental, respiratory and general health) outcomes; and analyses showed relationships between the number of measures installed and the total amount invested on the one hand and the social and health outcomes on the other. There were however a few exceptions. Most notably, the installation of cavity wall insulation was associated with poorer health outcomes, and did not lead to better social outcomes. Also, no association was found between the number of measures installed and respiratory health. The study suggests that substantial housing investments through a managed upgrade programme may result in better social and health outcomes, and that the size of the improvements are proportionate to the number of measures installed and amount invested. However, there may be risks associated with specific

  2. Impacts of the Weatherization Assistance Program in Fuel-Oil Heated Houses

    Energy Technology Data Exchange (ETDEWEB)

    Levins, W.P.

    1994-01-01

    installation labor and materials, and $627 for overhead and management), and the benefit-to-cost ratio was 1.48. A general trend toward higher-than-average fuel-oil savings was observed in houses with high pre-weatherization fuel-oil consumption. Program savings could likely be increased by targeting higher energy consumers for weatherization, although equity issues would have to be considered. Weatherization measures associated with higher-than-average savings were use of a blower door for air-sealing, attic and wall insulation, and replacement space-heating systems. Space-heating system tune-ups were not particularly effective at improving the steady-state efficiency of systems, although other benefits such as improved seasonal efficiency, and system safety and reliability may have resulted. The Program should investigate methods of improving the selection and/or application of space-heating system tune-ups and actively promote improved tune-up procedures that have been developed as a primary technology transfer activity. Houses were more air-tight following weatherization, but still leakier than what is achievable. Additional technology transfer effort is recommended to increase the use of blower doors considering that only half the weatherized houses used a blower door during air sealing. A guidebook developed by a committee of experts and covering a full range of blower-door topics might be a useful technology transfer and training document. Weatherization appeared to make occupants feel better about their house and house environment.

  3. A Fundamental Study of Stretch-Drawing Process of Sheet Metals : Single and Double Operations

    Science.gov (United States)

    Gotoh, Manabu; Kim, Young-soo; Yamashita, Minoru

    1998-05-01

    Fundamental and informative data of axisymmetric stretch-drawing of several sheet metals with thichness of 0.7 1.0 mm are presented especially for single and double operations. Very small radius is applied to the die-profile (or -shoulder) in all operations to induce wall-thinning by the effect of bending-under-tension, from which the name `stretch-drawing' comes. It is clearly demonstrated that deeper cups could be formed by the single and double stretch-drawings from smaller cirlcular blanks due to such wall-thinning action than in the usual deep-drawing of larger blanks. From this fact, it is emphasized that the deep-drawability of a sheet metal is not evaluated simply by the conventional LDR (=limiting drawing ratio), but the depth of the drawn cup should also be taken into account. Many experimental data about various metals and thicknesses given in this paper offer a valueable information on this process for more general use which recommends to replace the conventional deep-drawing process by the stretch-drawing process both for single and double operations. In the single stretch-drawing, it is also confirmed that a deeper cup can be produced by raising the blank-holding force at later stage of operation. Fracturing is found to occur at the middle section of the wall part or at the die-profile other than at the punch profile common in the usual deep-drawing process. Numerical simulation of the single stretch-drawing process is also performed by use of DYNA-3D code to confirm that a satisfactory prediction especially in the depth of the drawn-cup can be done at least in a practical sense, although this kind of numerical analysis is very difficult because of the severity or localization of deformation around the die profile. The drawn cup of SUS304 among others fractures in a couple of weeks after the operation due to the residual circumferential tensile stress, whereas that of SUS304L does not. In the double stretch-drawing, it is confirmed that very deeper

  4. High-pressure oxygenation of thin-wall YBCO single-domain samples

    International Nuclear Information System (INIS)

    Chaud, X; Savchuk, Y; Sergienko, N; Prikhna, T; Diko, P

    2008-01-01

    The oxygen annealing of ReBCO bulk material, necessary to achieve superconducting properties, usually induces micro- and macro-cracks. This leads to a crack-assisted oxygenation process that allows oxygenating large bulk samples faster than single crystals. But excellent superconducting properties are cancelled by the poor mechanical ones. More progressive oxygenation strategy has been shown to reduce drastically the oxygenation cracks. The problem then arises to keep a reasonable annealing time. The concept of bulk Y123 single-domain samples with thin-wall geometry has been introduced to bypass the inherent limitation due to a slow oxygen diffusion rate. But it is not enough. The use of a high oxygen pressure (16 MPa) enables to speed up further the process. It introduces a displacement in the equilibrium phase diagram towards higher temperatures, i.e., higher diffusion rates, to achieve a given oxygen content in the material. Remarkable results were obtained by applying such a high pressure oxygen annealing process on thin-wall single-domain samples. The trapped field of 16 mm diameter Y123 thin-wall single-domain samples was doubled (0.6T vs 0.3T at 77K) using an annealing time twice shorter (about 3 days). The initial development was made on thin bars. The advantage of thin-wall geometry is that such an annealing can be applied directly to a much larger sample

  5. Nordic Housing Enabler

    DEFF Research Database (Denmark)

    Helle, Tina; Brandt, Åse

    Development and reliability testing of the Nordic Housing Enabler – an instrument for accessibility assessment of the physical housing. Tina Helle & Åse Brandt University of Lund, Health Sciences, Faculty of Medicine (SE) and University College Northern Jutland, Occupational Therapy department (DK......). Danish Centre for Assistive Technology. Abstract. For decades, accessibility to the physical housing environment for people with functional limitations has been of interest politically, professionally and for the users. Guidelines and norms on accessible housing design have gradually been developed......, however, the built environment shows serious deficits when it comes to accessibility. This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of inter-rater reliability, when used in occupational therapy practice. The instrument was translated from...

  6. 20 CFR 654.407 - Housing.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Housing. 654.407 Section 654.407 Employees... EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.407 Housing. (a) Housing... occupants against the elements. (b) Housing shall have flooring constructed of rigid materials, smooth...

  7. Characteristics of wall pressure over wall with permeable coating

    Energy Technology Data Exchange (ETDEWEB)

    Song, Woo Seog; Shin, Seungyeol; Lee, Seungbae [Inha Univ., Incheon (Korea, Republic of)

    2012-11-15

    Fluctuating wall pressures were measured using an array of 16 piezoelectric transducers beneath a turbulent boundary layer. The coating used in this experiment was an open cell, urethane type foam with a porosity of approximately 50 ppi. The ultimate objective of the coating is to provide a mechanical filter to reduce the wall pressure fluctuations. The ultimate objective of the coating is to provide a mechanical filter to reduce the wall pressure fluctuations. The boundary layer on the flat plate was measured by using a hot wire probe, and the CPM method was used to determine the skin friction coefficient. The wall pressure autospectra and streamwise wavenumber frequency spectra were compared to assess the attenuation of the wall pressure field by the coating. The coating is shown to attenuate the convective wall pressure energy. However, the relatively rough surface of the coating in this investigation resulted in a higher mean wall shear stress, thicker boundary layer, and higher low frequency wall pressure spectral levels compared to a smooth wall.

  8. The role of outsourcing in the project house - mining house relationship

    OpenAIRE

    2008-01-01

    M.Phil. The relationship between the Mining House / Owner and Project House can be spectacularly successful for both partners (and has resulted in the emergence of a few successful new project houses and plant operation companies all over the world), but can also be disastrous for both parties, if managed incorrectly. The main requirement for a successful relationship between a Mining- and Project House is that there must be something in it for both parties. This is not only measured in cu...

  9. 3D mosquito screens to create window double screen traps for mosquito control.

    Science.gov (United States)

    Khattab, Ayman; Jylhä, Kaisa; Hakala, Tomi; Aalto, Mikko; Malima, Robert; Kisinza, William; Honkala, Markku; Nousiainen, Pertti; Meri, Seppo

    2017-08-29

    Mosquitoes are vectors for many diseases such as malaria. Insecticide-treated bed nets and indoor residual spraying of insecticides are the principal malaria vector control tools used to prevent malaria in the tropics. Other interventions aim at reducing man-vector contact. For example, house screening provides additive or synergistic effects to other implemented measures. We used commercial screen materials made of polyester, polyethylene or polypropylene to design novel mosquito screens that provide remarkable additional benefits to those commonly used in house screening. The novel design is based on a double screen setup made of a screen with 3D geometric structures parallel to a commercial mosquito screen creating a trap between the two screens. Owing to the design of the 3D screen, mosquitoes can penetrate the 3D screen from one side but cannot return through the other side, making it a unidirectional mosquito screen. Therefore, the mosquitoes are trapped inside the double screen system. The permissiveness of both sides of the 3D screens for mosquitoes to pass through was tested in a wind tunnel using the insectary strain of Anopheles stephensi. Among twenty-five tested 3D screen designs, three designs from the cone, prism, or cylinder design groups were the most efficient in acting as unidirectional mosquito screens. The three cone-, prism-, and cylinder-based screens allowed, on average, 92, 75 and 64% of Anopheles stephensi mosquitoes released into the wind tunnel to penetrate the permissive side and 0, 0 and 6% of mosquitoes to escape through the non-permissive side, respectively. A cone-based 3D screen fulfilled the study objective. It allowed capturing 92% of mosquitoes within the double screen setup inside the wind tunnel and blocked 100% from escaping. Thus, the cone-based screen effectively acted as a unidirectional mosquito screen. This 3D screen-based trap design could therefore be used in house screening as a means of avoiding infective bites and

  10. The zero-wall puncture: a novel angiographic puncture technique with substantial benefits

    International Nuclear Information System (INIS)

    Leswick, D.A.; Szkup, P.; Stoneham, G.W.

    2005-01-01

    Medical education can be busy, exhausting, and stressful, with potential adverse effects on trainees' physical and mental health. Radiology residency is no exception. In addition to increased daily workload and study requirements, Canadian radiology residents are performing a diverse and increasing number of emergent diagnostic examinations after hours. In an attempt to improve resident self-worth and efficiency during angiographic rotations, we investigated the effects of a novel angiographic puncture procedure on various resident lifestyle indexes. Standard techniques for accessing the femoral artery are either the single-wall puncture or double-wall puncture (Seldinger technique). Both of these techniques are widely known and practiced. Following procedure completion, hemostasis must be achieved at the puncture site. This has traditionally required manual compression at the puncture site, which may require 15 to 20 minutes. At our institution the standard policy is that 'whoever makes the puncture, compresses the groin,' also known as 'you broke it, you fix it'. This has prompted our industrious resident complement to develop a novel, previously undescribed, angiographic puncture technique known as the 'zero-wall puncture technique.' Preliminary unpublished results from our institution show that when residents employ the zero-wall puncture technique the attending staff radiologist subsequently both performs the puncture and compresses the groin at the end of the procedure. We investigated the effect of zero-wall puncture on various resident lifestyle indexes. (author)

  11. Modelling of phase change materials in the Toronto SUI net zero energy house using TRNSYS

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, O.; Fung, A.; Zhang, D. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Mechanical and Industrial Engineering

    2008-08-15

    In the context of building applications, phase change materials (PCM), can be defined as any heat storage material that can absorb a large amount of thermal energy while undergoing a change in phase, such as from a solid to a liquid phase. The incorporation of PCM into the building envelope can enhance occupant comfort through the reduction of indoor temperature fluctuations. It has also been shown to cause a decrease in the overall energy consumption associated with the heating and cooling of buildings. This paper extended the analysis of the impact of using PCM, which has traditionally focused on homes of ordinary construction, to incorporate low to zero energy homes using a model of the Toronto net zero energy house developed in TRNSYS. The paper provided a description of the TRNSYS model/methodology, with reference to the wall layer used in the net zero energy house, and model of the layout of the net zero energy house in TRYNSYS. The TRYNSYS/type 204 PCM component was also presented along with the simulation results in terms of the temperature profile of the third floor of the net zero energy house on a typical winter day with varying PCM concentrations; the temperature profile of the third floor of the net zero energy house on a typical summer day with varying PCM concentrations; yearly heating/cooling load requirements of the net zero energy house for a variety of thermal mass used; temperature profile of the third floor of the net zero energy house on a typical summer day when PCM and concrete slab was used; yearly temperature profile of the third floor of the net zero energy house, illustrating the impact of using PCM; and the yearly heating/cooling load of the net zero energy house as the concentration of PCM was varied. It was concluded that the use of building integrated PCM can reduce temperature fluctuations considerably in the summer but only slightly in the winter. 16 refs., 1 tab., 8 figs.

  12. Raman spectroscopic analysis of the carotenoid concentration in egg yolks depending on the feeding and housing conditions of the laying hens.

    Science.gov (United States)

    Hesterberg, Karoline; Schanzer, Sabine; Patzelt, Alexa; Sterry, Wolfram; Fluhr, Joachim W; Meinke, Martina C; Lademann, Jürgen; Darvin, Maxim E

    2012-01-01

    Resonance Raman spectroscopic measurements are suited to analyze the concentration of carotenoid antioxidants in biological samples. Previously, it has been shown that the carotenoid concentration of nutritional egg yolks has a direct influence on the carotenoid content of human skin in vivo. In the present study, resonance Raman spectroscopy was used to analyze the carotenoid concentration in the yolks of hen eggs, which were housed in battery cages or alternatively on free-range grassland. The egg yolks of hens, which had access to grassland, contained approximately double the amount of carotenoid concentration than the egg yolks of hens housed in battery cages (p egg yolks, depending on fodder, housing and weather conditions, were investigated. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Application of slightly acidic electrolyzed water for inactivating microbes in a layer breeding house.

    Science.gov (United States)

    Hao, X X; Li, B M; Wang, C Y; Zhang, Q; Cao, W

    2013-10-01

    Lots of microorganisms exist in layer houses can cause bird diseases and worker health concerns. Spraying chemical disinfectants is an effective way to decontaminate pathogenic microorganisms in the air and on surfaces in poultry houses. Slightly acidic electrolyzed water (SAEW, pH 5.0-6.5) is an ideal, environmentally friendly broad-spectrum disinfectant to prevent and control bacterial or viral infection in layer farms. The purpose of this work was to investigate the cleaning effectiveness of SAEW for inactivating the microbes in layer houses. The effect of SAEW was evaluated by solid materials and surface disinfection in a hen house. Results indicate that SAEW with an available chlorine concentration of 250 mg/L, pH value of 6.19, and oxygen reduction potential of 974 mV inactivated 100% of bacteria and fungi in solid materials (dusts, feces, feather, and feed), which is more efficient than common chemical disinfectant such as benzalkonium chloride solution (1:1,000 vol/vol) and povidone-iodine solution (1:1,000 vol/vol). Also, it significantly reduced the microbes on the equipment or facility surfaces (P < 0.05), including floor, wall, feed trough, and water pipe surfaces. Moreover, SAEW effectively decreased the survival rates of Salmonella and Escherichia coli by 21 and 16 percentage points. In addition, spraying the target with tap water before disinfection plays an important role in spray disinfection.

  14. Turbulent Non-Premixed Flames Stabilized on Double-Slit Curved Wall-Jet Burner with Simultaneous OH-Planar Laser-Induced Fluorescence and Particle Image Velocimetry Measurements

    KAUST Repository

    Mansour, Morkous S.

    2015-04-29

    A double-slit curved wall-jet (CWJ) burner utilizing a Coanda effect by supplying fuel and air as annular-inward jets over a curved surface was employed to investigate the stabilization characteristics and structure of propane/air turbulent non-premixed flames with varying global equivalence ratio and Reynolds number. Simultaneous time-resolved measurements of particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF) of OH radicals were conducted. The burner showed a potential of stable and non-sooting operation for relatively large fuel loading and overall rich conditions. Mixing characteristics in cold flow were first examined using an acetone fluorescence technique, indicating substantial transport between the fuel and air by exhibiting appreciable premixing conditions. PIV measurements revealed that the flow field consisted of a wall-jet region leading to a recirculation zone through flow separation, an interaction jet region resulting from the collision of annular-inward jets, followed by a merged-jet region. The flames were stabilized in the recirculation zone and, in extreme cases, only a small flame seed remained in the recirculation zone. Together with the collision of the slit jets in the interaction jet region, the velocity gradients in the shear layers at the boundaries of the annular jets generate the turbulence. Turbulent mean and rms velocities were influenced by the presence of the flame, particularly in the recirculation zone. Flames with a high equivalence ratio were found to be more resistant to local extinction and exhibited a more corrugated and folded nature, particularly at high Reynolds numbers. For flames with a low equivalence ratio, local quenching and re-ignition processes maintained flames in the merged jet region, revealing a strong intermittency, which was substantiated by the increased principal strain rates for these flames. © 2015 Taylor & Francis Group, LLC.

  15. Potential implementation of light steel housing system for affordable housing project in Malaysia

    Science.gov (United States)

    Saikah, M.; Kasim, N.; Zainal, R.; Sarpin, N.; Rahim, M. H. I. A.

    2017-11-01

    An unparalleled number between housing demand and housing supply in Malaysia has increased the housing prices, which gives consequences to the homeownership issue. One way to reduce the housing price is by faster increase the number of affordable housing, but the construction sector faces difficulties in delivering as expected number by using conventional and current industrialised building system (IBS) due to the issue related high project cost, time and labour. Therefore, light steel housing (LSH) system as one of another type of IBS method can be utilised in housing construction project. This method can replace the conventional method that was currently used in the construction of affordable housing project. The objectives of this study are to identify the potential of LSH and influencing factors of system implementation. This is an initial stage to review the previous study related to LSH implementation in developed and developing countries. The previous study will be analysed regarding advantages and disadvantages of LSH and factors that influence the implementation of the system. Based on the literature review it is expected to define the potential and influencing factors of the LSH system. The findings are meaningful in framing and enhance construction housing method of an affordable housing project in Malaysia.

  16. Assisted Housing - Housing Choice Vouchers by Tract - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The U.S. Department of Housing and Urban Development’s (HUD) Housing Choice Voucher Program (HCVP) is the federal government's major program for assisting very...

  17. Double Purse-String Telescoped Pancreaticogastro stomy using an Atraumatic Self-retaining Ring Retractor in a Subtotal Stomach-Preserving Pancreaticoduodenectomy.

    Science.gov (United States)

    Narita, Masato; Matsusue, Ryo; Hata, Hiroaki; Yamaguchi, Takashi; Otani, Tetsushi; Ikai, Iwao

    2016-03-01

    Pancreatoenteric anastomotic failure is the main cause of pancreatic fistula after pancreaticoduodenectomy (PD). Double purse-string telescoped pancreaticogastrostomy, reported by Addeo et al., is an easy and safe procedure.1 The aim of this article was to introduce our technique of pancreaticogastrostomy using an atraumatic self-retaining ring retractor (Alexis Wound Retractor) in a patient undergoing subtotal stomach-preserving PD (SSPPD). An 82-year-old woman presented with pancreatic cancer located in the uncinate process of pancreas. She underwent SSPPD with resection of the superior mesenteric vein (SMV) and double purse-string telescoped pancreaticogastrostomy using an Alexis wound retractor. The pancreas was transected on the portal vein and the remnant pancreas was separated from the splenic vein and artery. After extirpation of specimens and reconstruction of the SMV, two seromuscular purse-string sutures were placed on the posterior wall of the upper stomach. The anterior wall of the upper stomach was incised and opened using an Alexis wound retractor. The remnant pancreas was inserted into the gastric cavity through the posterior wall of the stomach and sutured circumferentially with running stitches to fix on the gastric muco-muscular layer. After closure of the anterior wall of the stomach, purse-string sutures were tightened and pancreaticogastrostomy was completed. The patient's postoperative course was uneventful and a computed tomography imaging study revealed no fluid collection around the pancreaticogastrostomy. This patient was discharged on the 14th postoperative day. Use of an Alexis wound retractor makes it easier to perform a double purse-string telescoped pancreaticogastrostomy by a self-expanding property to allow a wide operative view.

  18. 120 Years of U.S. Residential Housing Stock and Floor Space.

    Directory of Open Access Journals (Sweden)

    Maria Cecilia P Moura

    Full Text Available Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891-2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891-2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million square feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.

  19. A DFT comparative study of single and double SO2 adsorption on Pt-doped and Au-doped single-walled carbon nanotube

    International Nuclear Information System (INIS)

    Yoosefian, Mehdi; Zahedi, Mansour; Mola, Adeleh; Naserian, Samira

    2015-01-01

    Highlights: • Investigation of the adsorption of SO 2 on Au/SWCNT and Pt/SWCNT. • SO 2 adsorbed on Au/SWCNT and Pt/SWCNT system demonstrate a strong chemisorption. • NBO analysis was done to reach more understanding about intermolecular interactions. - Abstract: Adsorption of single and double SO 2 gas molecule(s) on the surface of Pt-doped and Au-doped (5,5) single-walled carbon nanotubes (Pt/CNT-V and Au/CNT-V) were investigated by using density functional theory (DFT) at B3LYP/LANL2DZ level. The results showed the following: firstly, adsorption on Au/CNT-V is independent of special orientation, secondly, SO 2 adsorption on Pt/CNT-V in single case is stronger than Au/CNT-V, and finally, adsorption of the first molecule influences adsorption of the second one. Upon adsorption of SO 2 molecule(s), the energy gap of Pt/CNT-V were considerably reduced, resulting in enhanced electrical conductivity but in Au/CNT-V, despite of adsorption energy similar to Pt/CNT-V, E g slightly increased. In order to consider the effect of adsorption on electronic properties, DOS and PDOS calculations were performed. Moreover, NBO analysis was done to reach more understanding about intermolecular interactions. In conclusion, chemical reactivity was investigated in terms of chemical hardness, softness and work function (ϕ)

  20. Thermal design of a modern, two floor, zero energy house in a desert compound

    KAUST Repository

    Serag-Eldin, M. A.

    2010-12-01

    The paper presents a thermal analysis and design of a fully equipped, air-conditioned, zero energy house located in a desert compound at 24.5° latitude. Unlike previous designs the home is two floors high, which makes the balancing of energy supply and demand even more challenging. The roof of the house carries an array of retractable Photovoltaic modules and cover. During day light hours the modules convert the incident sun energy into useful electrical power, while shielding the roof from direct sun-radiation. At night time, the roof cover and modules are retracted to expose the roof to the cool night-sky, thus enhancing cooling. The paper employs time-dependent modeling of Solar input and heat transfer to predict the roof, wall and window temperature distributions and cooling loads, as well as energy generated by the modules. With the aid of battery storage, the modules provide the entire energy needs of the house. The paper displays the results of energy balances for three key days of the year which demonstrate that the proposed two floor design is indeed capable of operating without external energy. © 2010 IEEE.