WorldWideScience

Sample records for double lumen tube

  1. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    Science.gov (United States)

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  2. Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe

    2014-09-01

    The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.

  3. Influence of a Double-Lumen Extension Tube on Drug Delivery: Examples of Isosorbide Dinitrate and Diazepam.

    Directory of Open Access Journals (Sweden)

    Aurélie Maiguy-Foinard

    Full Text Available Plastic materials such as polyurethane (PUR, polyethylene (PE, polypropylene (PP and polyvinyl chloride (PVC are widely used in double-lumen extension tubing. The purposes of our study were to 1 compare in vitro drug delivery through the double extension tubes available on the market 2 assess the plastic properties of PUR in infusion devices and their impact on drug delivery.The study compared eight double-lumen extension tubes in PUR, co-extruded (PE/PVC plastic and plasticised PVC from different manufacturers. Isosorbide dinitrate and diazepam were used as model compounds to evaluate their sorption on the internal surface of the infusion device. Control experiments were performed using norepinephrine known not to absorb to plastics. Drug concentrations delivered at the egress of extension tubes were determined over time by an analytical spectrophotometric UV-Vis method. The main characteristics of plastics were also determined.Significant differences in the sorption phenomenon were observed among the eight double-lumen extension tubes and between pairs of extension tubes. Mean concentrations of isosorbide dinitrate delivered at the egress of double-lumen extension tubes after a 150-minute infusion (mean values ± standard deviation in percentage of the initial concentrations in the prepared syringes ranged between 80.53 ± 1.66 (one of the PUR tubes and 92.84 ± 2.73 (PE/PVC tube. The same parameters measured during diazepam infusion ranged between 48.58 ± 2.88 (one of the PUR tubes and 85.06 ± 3.94 (PE/PVC tube. The double-lumen extension tubes in PUR were either thermosetting (resin or thermoplastic according to reference.Clinicians must be aware of potential drug interactions with extension tube materials and so must consider their nature as well as the sterilisation method used before selecting an infusion device.

  4. "Detachment of the carinal hook following endobronchial intubation with a double lumen tube"

    Directory of Open Access Journals (Sweden)

    Rocha Ana C

    2011-10-01

    Full Text Available Abstract Background Carinal hooks increases difficulty at endotracheal intubation. Amputation of the carinal hook during passage and malpositioning of the tube to the hook are some of the potential problems related with left-sided Carlens double lumen tube (DLT. This article reports an amputation of the hook during a difficult selective intubation and aimed at calling the attention to complications associated with DLTs and the importance of fiberoptic bronchoscopy. Case presentation A 68 year-old woman was scheduled for right-sided thoracotomy in whom blind DLT insertion was performed. Narrowed trachea causes difficulty in rotating the DLT 90° counter-clockwise. After carinal hook was noticed upon visual inspection of the DLT, fiberoptic bronchoscopy was used to remove the missing part (with the use of forceps from the right mainstem bronchus. Conclusion Insertion of DLTs with carinal hook is associated with technical problems and potentially life-threatening hazards have discouraged their use. Fiberoptic evaluation and repositioning solves most of the problems. Although amputation of the carinal hook has not been previously reported, clinicians should be alert. This case report emphasizes the utility of the fiberoptic bronchoscopy in the operating theatre for placement, positioning and inspection of the carinal hook DLT.

  5. Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.

    Science.gov (United States)

    Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon

    2018-04-01

    The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube.

    Science.gov (United States)

    Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei

    2018-03-01

    This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs).A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis.When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P auscultation (67.4% [52.0%, 80.5%]) (P auscultation (54.4% [40.7%, 67.6%]) (P auscultation (47.8% [32.9%, 63.1%]) (P auscultation in determining the position of DLTs.

  7. Double-lumen tubes and auto-PEEP during one-lung ventilation.

    Science.gov (United States)

    Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T

    2016-01-01

    Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. High-fidelity simulation of lung isolation with double-lumen endotracheal tubes and bronchial blockers in anesthesiology resident training.

    Science.gov (United States)

    Failor, Erin; Bowdle, Andrew; Jelacic, Srdjan; Togashi, Kei

    2014-08-01

    Demonstrate the feasibility of using the AirSim Bronchi airway simulator to teach residents how to manage lung isolation with double-lumen endotracheal tubes and bronchial blockers and evaluate their performance with a detailed checklist. Prospective observational study. University anesthesiology residency training program. Anesthesiology residents taking a cardiothoracic anesthesiology rotation. Residents were instructed in 7 tasks using the AirSim Bronchi: The use of the fiberoptic bronchoscope, methods for placing left and right double-lumen endotracheal tubes and 3 bronchial blockers (Univent, Arndt, and Cohen), and application of continuous positive airway pressure (CPAP) to the unventilated lung. Two to 3 weeks later, checklists and a detailed scoring system were used to assess performance. Residents rated the curriculum and their own confidence in performing the tasks using a 5-point Likert scale. Thirteen residents completed the curriculum. Their median Likert scale ratings of the curriculum based on a questionnaire with 6 items ranged from 4 to 5 of 5. Resident confidence scores for each lung isolation technique improved after the simulation training, with the median gain ranging from 0.5 to 1.5 Likert levels depending on the task. The largest improvement occurred with the bronchial blockers (psimulator in a novel simulation curriculum to teach lung-isolation techniques to anesthesiology residents and evaluated performance using a detailed checklist scoring system. This curriculum is a promising educational tool. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. [Successful double-lumen endotracheal tube exchange with a soft-tipped extra firm exchange catheter in a patient with severe subcutaneous emphysema].

    Science.gov (United States)

    Okamoto, Kaori; Komasawa, Nobuyasu; Ishio, Junichi; Nakano, Shoko; Tatsumi, Shinichi; Minami, Toshiaki

    2014-07-01

    We report a case of successful double-lumen endotracheal tube exchange with a soft-tipped extra firm exchange catheter in a patient with severe subcutaneous emphysema. A 70-year-old man underwent right lower lobectomy for primary lung cancer under general anesthesia. He developed pneumothorax on postoperative day (POD) 14, which led to subcutaneous emphysema. An emergent operation was performed on POD20 to close the pulmonary fistula under general anesthesia with a single-lumen endotracheal tube and bronchial blocker. Subcutaneous emphysema became worse and pharyngeal emphysema was also suspected; re-operation to close the pulmonary or bronchial fistula was planned. We decided to place a double-lumen tube to precisely detect the fistula. Under the guide of a Pentax-AWS Airwayscope, the single-lumen endotracheal tube was exchanged uneventfully to a 35 Fr double-lumen endotracheal tube with a 110 cm soft-tipped extra firm exchange catheter. The fistula was detected by a leak test and the operation was performed uneventfully, leading to improvement of subcutaneous emphysema.

  10. Combination of intravenous dexmedetomidine with topicalization of airway for placement of double lumen tube in a spontaneously breathing patient of giant lung bullae

    Directory of Open Access Journals (Sweden)

    Vikas Karne

    2016-10-01

    Here we present a patient with giant lung bulla in left lower lobe with severely reduced pulmonary reserves and significant air-trapping posted for VAT assisted bullectomy. Anaesthesia challenges including pathological changes, its effects during induction of anaesthesia, and issues related to placement of double lumen tube in a spontaneously breathing patient are discussed with possible advantages of dexmedetomidine in this special group of patients.

  11. Disconnection technique with a bronchial blocker for improving lung deflation: a comparison with a double-lumen tube and bronchial blocker without disconnection.

    Science.gov (United States)

    Yoo, Ji Young; Kim, Dae Hee; Choi, Ho; Kim, Kun; Chae, Yun Jeong; Park, Sung Yong

    2014-08-01

    One-lung ventilation (OLV) is accomplished with a double-lumen tube (DLT) or a bronchial blocker (BB). The authors compared the effectiveness of lung collapse using DLT, BB, and BB with the disconnection technique. Prospective, randomized, blind trial. A university hospital. Fifty-two patients undergoing elective pneumothorax surgery. Patients were assigned randomly to 1 of 3 groups: The DLT group (group 1), the BB group (group 2), and the BB with the disconnection technique group (group 3). The authors modified the disconnection technique in group 3 as follows: (1) turned off the ventilator and opened the adjustable pressure-limiting valve, allowing both lungs to collapse and (2) after loss of the CO2 trace on the capnograph, inflated the blocker cuff and turned on the ventilator, allowing only dependent-lung ventilation. Five and ten minutes after OLV, the degree of lung collapse was assessed by the surgeon, who was blinded to the isolation technique. The quality of lung collapse at 5 and 10 minutes was significantly better in groups 1 and 3 than in group 2. No significant differences were observed for the degree of lung collapse at any time point between groups 1 and 3. The average time for loss of the CO2 trace on the capnograph was 32.3±7.0 seconds in group 3. A BB with spontaneous collapse took longer to deflate and did not provide equivalent surgical exposure to the DLT. The disconnection technique could be helpful to accelerate lung collapse with a BB. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Bronchial blocker versus left double-lumen endotracheal tube in video-assisted thoracoscopic surgery: a randomized-controlled trial examining time and quality of lung deflation.

    Science.gov (United States)

    Bussières, Jean S; Somma, Jacques; Del Castillo, José Luis Carrasco; Lemieux, Jérôme; Conti, Massimo; Ugalde, Paula A; Gagné, Nathalie; Lacasse, Yves

    2016-07-01

    Double-lumen endotracheal tubes (DL-ETT) and bronchial blockers (BB) have both been used for lung isolation in video-assisted thoracic surgery (VATS). Though not well studied, it is widely thought that a DL-ETT provides faster and better quality lung collapse. The aim of this study was to compare a BB technique vs a left-sided DL-ETT strategy with regard to the time and quality of lung collapse during one-lung ventilation (OLV) for elective VATS. Forty patients requiring OLV for VATS were randomized to receive a BB (n = 20) or a left-sided DL-ETT (n = 20). The primary endpoint was the time from pleural opening (performed by the surgeon) until complete lung collapse. The time was evaluated offline by reviewing video recorded during the VATS. The quality of lung deflation was also graded offline using a visual scale (1 = no lung collapse; 2 = partial lung collapse; and 3 = total lung collapse) and was recorded at several time points after pleural incision. The surgeon also graded the time to complete lung collapse and quality of lung deflation during the procedure. The surgeon's guess as to which device was used for lung isolation was also recorded. Of the 40 patients enrolled in the study, 20 patients in the DL-ETT group and 18 in the BB group were analyzed. There mean (standard deviation) time to complete lung collapse of the operative lung was significantly faster using the BB compared with using the DL-ETT [7.5 (3.8) min vs 36.6 (29.1) min, respectively; mean difference, 29.1 min; 95% confidence interval, 1.8 to 7.2; P < 0.001]. Overall, a higher proportion of patients in the BB group than in the DL-ETT group achieved a quality of lung collapse score of 3 at five minutes (57% vs 6%, respectively; P < 0.004), ten minutes (73% vs 14%, respectively; P = 0.005), and 20 min (100% vs 25%, respectively; P = 0.002) after opening the pleura. The surgeon incorrectly guessed the type of device used in 78% of the BB group and 50% of the DL-ETT group (P = 0.10). The time and

  13. Bronchial Blocker Versus Left Double-Lumen Endotracheal Tube for One-Lung Ventilation in Right Video-Assisted Thoracoscopic Surgery.

    Science.gov (United States)

    Lu, Yao; Dai, Wei; Zong, Zhijun; Xiao, Yimin; Wu, Di; Liu, Xuesheng; Chun Wong, Gordon Tin

    2018-02-01

    The aim of this study was to compare the quality of lung deflation of a left-sided double-lumen endotracheal tube (DLT) with a bronchial blocker (BB) for one-lung ventilation in video-assisted thoracic surgery (VATS). A prospective, randomized, clinical study. A university-affiliated teaching hospital. Forty-five adult patients undergoing esophageal tumor surgery using VATS with right lung deflation. Patients were assigned by a computer-generated randomization sequence to either the left-sided DLT or BB group. The correct positioning of the airway device was confirmed using fiberoptic bronchoscopy. The variables assessed included: (1) time required to correctly place the devices and to achieve lung collapse; (2) the number of times the device malpositioned; (3) the quality of lung deflation as rated by the surgeon; (4) blood pressure and heart rate at baseline (T 1 ), immediately before (T 2 ) and after (T 3 ) and 1 minute (T 4 ) after intubation; (5) the number of patients with hypoxemia (SpO 2 one-lung ventilation (OLV) period; and (6) postoperative hoarseness of voice, sore throat, or pulmonary infection. Of the 45 patients approached for the study, 21 patients in the DLT group and 19 patients in the BB group were analyzed. The time required to place the device in the correct position was similar between the 2 groups. The time to achieve right lung collapse in the BB group was significantly longer (mean difference: 3.232, 95% confidence interval [CI]: 1.993-4.471; p = 0.003). The quality of lung collapse, OLV duration, number of patients with device malposition, and hypoxemia in both groups were similar. There were more patients suffering hoarseness (odds ratio [OR]: 4.85, 95% CI: 1.08-21.76; p = 0.034) or sore throat (OR: 4.29, 95% CI: 1.14-16.18; p = 0.030) in the DLT group, while no patients developed postoperative lung infection in either group. Compared to T 1 , systolic blood pressure (sBP), diastolic BP (dBP), and heart rate (HR) at T 2 in both groups

  14. [Successful One-lung Ventilation with a Right-sided Double-lumen Tube in a Patient with a Right Upper Tracheal Bronchus, who Underwent Left Pneumonectomy for Left Hilar Lung Cancer].

    Science.gov (United States)

    Kawagoe, Izumi; Kohchiyama, Tsukasa; Hayashida, Masakazu; Satoh, Daizoh; Suzuki, Kenji; Inada, Eiichi

    2016-06-01

    A 60-year-old male patient with left hilar lung cancer was scheduled to undergo left pneumonectomy or left sleeve lower lobectomy. Preoperative computer tomographic and bronchoscopic examinations revealed that the bronchus (B1) to the right apical segment (S1) was a tracheal bronchus (TB) originating from the trachea approximately 10 mm above the carina. Because the left main bronchus was to be dissected, a right-sided double-lumen tube (DLT) was selected to completely protect the right lung from spillage of secretions or cancer cells from the left lung. The right-sided DLT was placed so as to fit its lateral opening of the bronchial lumen to normal upper branches (B2, B3), while sacrificing ventilation of S1 with an abnormal branch (B1). However, one-lung ventilation (OLV) of the right lung could not be achieved, since a gas leakage from the opened tracheal lumen occurred, most probably due to intra-lobar micro-airway communications between S1 and S2/S3. The DLT was withdrawn until the blue bronchial cuff occluded the orifice of the TB (B1). Although the upper half of the blue bronchial cuff appeared above the tracheal carina, OLV through the two bronchial lumen openings could be achieved due to a specific, slanted doughnut shape of the blue bronchial cuff and the location of the abnormal branch (B1) approximate to the carina. Left pneumonectomy using successful OLV was completed safely without hypoxemia or hypercapnea. Our experience indicates that management of OLV for patients with a thoracheal bronchus needs special considerations of the exact location of the TB and intra-lobar micro-airway communications, in addition to types of scheduled surgical procedures.

  15. Successful 1:1 proportion ventilation with a unique device for independent lung ventilation using a double-lumen tube without complications in the supine and lateral decubitus positions. A pilot study.

    Directory of Open Access Journals (Sweden)

    Michał Kowalczyk

    Full Text Available Adequate blood oxygenation and ventilation/perfusion matching should be main goal of anaesthetic and intensive care management. At present, one of the methods of improving gas exchange restricted by ventilation/perfusion mismatching is independent ventilation with two ventilators. Recently, however, a unique device has been developed, enabling ventilation of independent lungs in 1:1, 2:1, 3:1, and 5:1 proportions. The main goal of the study was to evaluate the device's utility, precision and impact on pulmonary mechanics. Secondly- to measure the gas distribution in supine and lateral decubitus position.69 patients who underwent elective thoracic surgery were eligible for the study. During general anaesthesia, after double lumen tube intubation, the aforementioned control system was placed between the anaesthetic machine and the patient. In the supine and lateral decubitus (left/right positions, measurements of conventional and independent (1:1 proportion ventilation were performed separately for each lung, including the following: tidal volume, peak pressure and dynamic compliance.Our results show that conventional ventilation using Robertshaw tube in the supine position directs 47% of the tidal volume to the left lung and 53% to the right lung. Furthermore, in the left lateral position, 44% is directed to the dependent lung and 56% to the non-dependent lung. In the right lateral position, 49% is directed to the dependent lung and 51% to the non-dependent lung. The control system positively affected non-dependent and dependent lung ventilation by delivering equal tidal volumes into both lungs with no adverse effects, regardless of patient's position.We report that gas distribution is uneven during conventional ventilation using Robertshaw tube in the supine and lateral decubitus positions. However, this recently released control system enables precise and safe independent ventilation in the supine and the left and right lateral decubitus

  16. Positive pressure ventilation in a patient with a right upper lobar bronchocutaneous fistula: right upper bronchus occlusion using the cuff of a left-sided double lumen endobronchial tube.

    Science.gov (United States)

    Omori, Chieko; Toyama, Hiroaki; Takei, Yusuke; Ejima, Yutaka; Yamauchi, Masanori

    2017-08-01

    In patients with a bronchocutaneous fistula, positive pressure ventilation leads to air leakage and potential hypoxemia. A male patient with a right upper bronchocutaneous fistula was scheduled for esophageal reconstruction. His preoperative chest computed tomography image revealed aeration in the right middle and lower lobe, a large bulla in the left upper lobe, and pleural effusion and pneumonia in the left lower lobe. Therefore, left one-lung ventilation was considered to result in hypoxemia. Before anesthesia induction, the bronchocutaneous fistula was covered with gauze and film to prevent air leakage. After anesthesia induction, mask ventilation was performed with a peak positive pressure of 10 cmH 2 O. A left-sided double lumen endobronchial tube (DLT) was then inserted into the right main bronchus for occluding only the right superior bronchus, and two-lung ventilation was performed to minimize airway pressure and maintain oxygenation, which did not cause air leakage through the fistula. During anesthesia, no ventilation-related difficulty was faced. The method of inserting a left-sided DLT into the right main bronchus and occluding the right upper bronchus selectively by bronchial cuff is considered to be an option for mechanical ventilation in patients with a right upper bronchial fistula, as demonstrated in the present case.

  17. Double wall steam generator tubing

    International Nuclear Information System (INIS)

    Padden, T.R.; Uber, C.F.

    1983-01-01

    Double-walled steam generator tubing for the steam generators of a liquid metal cooled fast breeder reactor prevents sliding between the surfaces due to a mechanical interlock. Forces resulting from differential thermal expansion between the outer tube and the inner tube are insufficient in magnitude to cause shearing of base metal. The interlock is formed by jointly drawing the tubing, with the inside wall of the outer tube being already formed with grooves. The drawing causes the outer wall of the inner tube to form corrugations locking with the grooves. (author)

  18. Clinical application of hysterosalpingography with a double-lumen catheter of a contrast media combination consisting iohexol and saline

    International Nuclear Information System (INIS)

    Xi Jiayuan; Jiang Yong; Cao Xinhua; Zhu Ying; Lv Liang; Zhao Xinxiang; Wei Dingying; Shao Jingxuan; Hua Jian

    2005-01-01

    Objective: To evaluate the clinical value of hysteosalpingographic diagnosis in infertile women. Methods: After a catheter with a double-lumen saccule was inserted into the uterine cavity, saline or air of 2.5-3.5 ml was injected to fill the saccule. The filled saccule was inserted at the isthmus of uterus for blocking the internal orifice. The contrast medium was injected through the catheter into the uterine cavity and fallopian tubes to undertake hysterosalpingography and fallopian tube reopening. In case of fallopian tube obstruction, the injection pressure could be increased to obtain recanalization. All operations and selective imagings were carried out under TV supervision. Results: 2698 cases including 806 primary infertile women and 1868 secondary infertile women were examined by this method. Technical success rate was 99.5% with 2198 cases (81.9%) having normal uterus, 249 (9.3%) congenital abnormal uterus and 238 (8.9%) uterus diseases. The number of obstructed fallopian tube was 3028 with 117 serious hydropsy (3.8%). Ninety-eight cases had been examined with lipiodol hysterosalpingography in other hospitals with 35 cases still having lipiodol accumulated within the uterine cavities and fallopian tubes. No serious complications or death occurred except slight pain. Conclusions: Double-lumen cather with a contrast media combination of iohexol and saline for hysterosal pinography is safe, easy and effective, outcoming with excellent quality images. More information can be gained with this method than traditional lipiodol hyterosalpinography, and furthermore could have compression during radiogrophy and avoid the long term stasis of lipiodol. (authors)

  19. Thrombosis caused by polyurethane double-lumen subclavian superior vena cava catheter and hemodialysis

    DEFF Research Database (Denmark)

    Wanscher, Maria Rørbæk; Frifelt, J J; Smith-Sivertsen, C

    1988-01-01

    During an 18-month period, 82 consecutive patients (37 women and 45 men), with a mean age of 50 yr (range 15 to 74), underwent hemodialysis with 91 polyurethane double-lumen subclavian superior vena cava catheters inserted via the right subclavian vein. Upon catheter removal, venograms were...

  20. Pancreatic Necrosectomy Through a Novel Double-flange Lumen-apposing Covered Metal Stent (Video

    Directory of Open Access Journals (Sweden)

    Andres Sanchez-Yague

    2014-12-01

    A double flange lumen apposing FC-SEMS used as a port for necrosectomy significantly improves management of walled-off pancreatic necrosis. Placement of this stents should be considered when multiple necrosectomy sessions are anticipated. Procedure time can be significantly decreased using a catheter that combines a cautery tip and stent delivery system.

  1. Free Piston Double Diaphragm Shock Tube

    OpenAIRE

    OGURA, Eiji; FUNABIKI, Katsushi; SATO, Shunichi; ABE, Takashi; 小倉, 栄二; 船曳, 勝之; 佐藤, 俊逸; 安部, 隆士

    1997-01-01

    A free piston double diaphragm shock tube was newly developed for generation of high Mach number shock wave. Its characteristics was investigated for various operation parameters; such as a strength of the diaphragm at the end of the comparession tube, an initial pressure of low pressure tube, an initial pressure of medium pressure tube and the volume of compression tube. Under the restriction of fixed pressures for the driver high pressure tube (32×10^5Pa) and the low pressure tube (40Pa) in...

  2. Camera Embedded Single Lumen Tube as a Rescue Device for Airway Handling during Lung Separation

    DEFF Research Database (Denmark)

    Højberg Holm, Jimmy; Andersen, Claus

    2016-01-01

    .Keywords: Thoracic anesthesia; Airway handling; VivaSight; Vivasight-SL; Lobectomy; Camera-embedded tube; Endotracheal; Lung isolation; Video tube Taking the small stature into account, use of a small conventional 35-Fr right sided DLT was planned for the procedure. As it turned out, this tube could not be passed...

  3. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D; Tvede, Michael

    2010-01-01

    with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes (silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system...... and biofilms were produced during a 3 day period. Tubes in lengths of 10 (Teflon, silicone) and 20 cm (Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were...... in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit...

  4. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, S.D.; Tvede, M.

    2010-01-01

    with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes ( silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system...... and biofilms were produced during a 3 day period. Tubes in lengths of 10 ( Teflon, silicone) and 20 cm ( Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were...... in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit...

  5. Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter.

    Science.gov (United States)

    Rosetti, Késia Alves Gomes; Tronchin, Daisy Maria Rizatto

    2014-01-01

    to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo. a quantitative, exploratory-descriptive and observational study. The sample was made up of 155 observations of persons with temporary double-lumen catheters, in the period March-November 2011, using the Indicator of the Maintenance of the Temporary Double Lumen Catheter for Hemodialysis. the rate of general conformity of the assistential practice corresponded to 65.8%. Of the practice's 13 components, 9 (69.2%) attained 100% conformity. The hygienization of hands by the professionals and the use of a mask by the patients during the disconnection from the hemodialysis had the worst rates (83.9%). although the actions evaluated are implemented in the unit, it is necessary to propose and apply educational strategies with the health team, as well as to institute periodical assessments, so as to raise the conformity rates, ensuring the quality of the hemodialysis services.

  6. Single- and double- lumen silicone breast implant integrity: prospective evaluation of MR and US criteria.

    Science.gov (United States)

    Berg, W A; Caskey, C I; Hamper, U M; Kuhlman, J E; Anderson, N D; Chang, B W; Sheth, S; Zerhouni, E A

    1995-10-01

    To evaluate the accuracy of magnetic resonance (MR) and ultrasound (US) criteria for breast implant integrity. One hundred twenty-two single-lumen silicone breast implants and 22 bilumen implants were evaluated with surface coil MR imaging and US and surgically removed. MR criteria for implant failure were a collapsed implant shell ("linguine sign"), foci of silicone outside the shell ("noose sign"), and extracapsular gel, US criteria were collapsed shell, low-level echoes within the gel, and "snowstorm" echoes of extracapsular silicone. Among single-lumen implants, MR imaging depicted 39 of 40 ruptures, 14 of 28 with minimal leakage; 49 of 54 intact implants were correctly interpreted. US depicted 26 of 40 ruptured implants, four of 28 with minimal leakage, and 30 of 54 intact implants. Among bilumen implants, MR imaging depicted four of five implants with rupture of both lumina and nine of 10 as intact; US depicted one rupture and helped identify two of 10 as intact. Mammography accurately depicted the status of 29 of 30 bilumen implants with MR imaging correlation. MR imaging depicts implant integrity more accurately than US; neither method reliably depicts minimal leakage with shell collapse. Mammography is useful in screening bilumen implant integrity.

  7. Heat transfer in laminar flow for a finned double - tube

    International Nuclear Information System (INIS)

    Colle, S.

    1977-01-01

    An analitical study of the steady-state heat transfer in laminar flow in finned double-tube heat exchangers is presented. The fins are plane, straight and continous, equally spaced and are fixed over the external surface of the inner tube. A constant peripheral temperature distribution is assumed to apply over the inner tube surface and each fin, and a constant peripheral heat flux is assumed to apply over the outer tube surface, while the overall heat flux is suposed to be uniform in the longitudinal direction of the duct. The prediction of the thermal performance of the finned double-tube is made by means of the relationship between the Nusselt number, the boundary conditions and the geometric characteristcs of the duct. (author) [pt

  8. Performance analysis of double basin solar still with evacuated tubes

    International Nuclear Information System (INIS)

    Hitesh N Panchal; Shah, P. K.

    2013-01-01

    Solar still is a very simple device, which is used for solar distillation process. In this research work, double basin solar still is made from locally available materials. Double basin solar still is made in such a way that, outer basin is exposed to sun and lower side of inner basin is directly connected with evacuated tubes to increase distillate output and reducing heat losses of a solar still. The overall size of the lower basin is about 1006 mm x 325 mm x 380 mm, the outer basin is about 1006 mm x 536 mm x 100 mm Black granite gravel is used to increase distillate output by reducing quantity of brackish or saline water in the both basins. Several experiments have conducted to determine the performance of a solar still in climate conditions of Mehsana (latitude of 23 degree 59' and longitude of 72 degree 38'), Gujarat, like a double basin solar still alone, double basin solar still with different size black granite gravel, double basin solar still with evacuated tubes and double basin solar still with evacuated tubes and different size black granite gravel. Experimental results show that, connecting evacuated tubes with the lower side of the inner basin increases daily distillate output of 56% and is increased by 60%, 63% and 67% with average 10 mm, 20 mm and 30 mm size black granite gravel. Economic analysis of present double basin solar still is 195 days. (authors)

  9. Thermal optimization of primary side in double-tube OTSG

    International Nuclear Information System (INIS)

    Wei Xinyu; Dai Chunhui; Hou Suxia; Tai Yun; Zhao Fuyu

    2011-01-01

    Once-through steam generator (OTSG) is usually used in the integrated nuclear power plants which require smaller volume and better effect of heat transfer. The double-tube OTSG component which is composed of straight tube outside and helical tube inside is presented in this paper. The primary fluid is divided into two parts, one is in the inner tube and the other is in the gap among outer tubes. The flow distribution ratio of the primary fluid obviously affects the heat transfer. Thus, the problem of optimization emerges, i.e. how to find an optimal flow distribution ratio with a maximum heat exchange. Analyzed the effects of the distribution ratio on heat transfer, the optimal distribution ratio is obtained by the constrained nonlinear optimization method. Subsequently, the optimal distribution ratio is achieved by a throttling set in the entrance of the inner tube. The result is in substantial agreement with the literature. (author)

  10. Development of the double-wall-tube steam generator. Evaluation of inner tube leak detection system

    International Nuclear Information System (INIS)

    Teraoku, Takuji; Kisohara, Naoyuki

    1995-01-01

    A double-wall-tube steam generator (DWT-SG) is considered to have possibility of eliminating a secondary heat transport system to realize a reliable and simplified FBR plant. Thus, basic tests for inner/outer tube leak detection and prototypical leak tests by use of the 1MWt DWT-SG model have been performed to evaluate the feasibility of DWT-SG. Their results demonstrated that the inner leak detection system can definitely detect a steam leak from an inner tube flaw. Analyses of the inner tube leak and detection behavior obtained in the 1MWt DWT-SG test enabled to estimate the performance of the inner tube detection system of the commercial DWT-SG system. (author)

  11. Core design of super LWR with double tube water rods

    International Nuclear Information System (INIS)

    Wu, Jianhui; Oka, Yoshiaki

    2014-01-01

    Highlights: • Supercritical light water cooled and moderated reactor with double tube water rods is developed. • Double-row fuel rod assembly and out-in fuel loading pattern are applied. • Separation plates in peripheral assemblies increase average outlet temperature. • Neutronic and thermal design criteria are satisfied during the cycle. - Abstract: Double tube water rods are employed in core design of super LWR to simplify the upper core structure and refueling procedure. The light water moderator flows up in the inner tube from the bottom of the core, then, changes the flow direction at the top of the core into the outer tube and flows out at the bottom of the core. It eliminates the moderator guide/distribution tubes into the single tube water rods from the top dome of the reactor pressure vessel of the previous super LWR design. Two rows of fuel rods are filled between the water rods in the fuel assembly. Out-in refueling pattern is adopted to flatten radial power distribution. The peripheral fuel assemblies of the core are divided into four flow zones by separation plates for increasing the average core outlet temperature. Three enrichment zones are used for axial power flattening. The equilibrium core is analyzed based on neutronic/thermal-hydraulic coupled model. The results show that, by applying the separation plates in peripheral fuel assemblies and low gadolinia enrichment, the maximum cladding surface temperature (MCST) is limited to 653 °C with the average outlet temperature of 500 °C. The inherent safety is satisfied by the negative void reactivity effects and sufficient shutdown margin

  12. Light Production in the Double Chooz Photomultiplier Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, E.; Cerrada, M.; Crespo, J. I.; Gil-Botella, I.; Jimenez, S.; Lopez, M.; Novella, P.; Palomares, C.; Santorelli, R.; Verdugo, A.

    2012-09-13

    In this document we present a study of the phenomenon of light emission (called glowing) in the bases of the Hamamatsu R7081MOD-ASSY photomultiplier tubes (PMTs) used in the Double Chooz experiment. The tests have been carried out at the CIEMAT laboratories over a photomultiplier tube of the same model. We have studied the phenomenon making first a characterization of it, and then focusing on the dependence of the rate and the amount of emitted light versus voltage and temperature. In addition, we have looked for the possible existence of an ultraviolet component in the light which would be harmful for the experiment because it could be able to excite the scintillator liquid. Finally, we propose and test a method to reduce the light emission using a cover on the base of the photomultiplier tube.. (Author)

  13. The single chest tube versus double chest tube application after pulmonary lobectomy: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Xuefei Zhang

    2016-01-01

    Conclusion: Compared with the double chest tube, the single chest tube significantly decreases amount of drainage, duration of chest tube drainage, pain score, the number of patients who need thoracentesis, and cost. Although there is convincing evidence to confirm the results mentioned herein, they still need to be confirmed by large-sample, multicenter, randomized, controlled trials.

  14. Peptide signalling during the pollen tube journey and double fertilization.

    Science.gov (United States)

    Qu, Li-Jia; Li, Ling; Lan, Zijun; Dresselhaus, Thomas

    2015-08-01

    Flowering seed plants (angiosperms) have evolved unique ways to protect their gametes from pathogen attack and from drying out. The female gametes (egg and central cell) are deeply embedded in the maternal tissues of the ovule inside the ovary, while the male gametes (sperm cells) are enclosed in the vegetative pollen tube cell. After germination of the pollen tube at the surface of papilla cells of the stigma the two immobile sperm cells are transported deep inside the sporophytic maternal tissues to be released inside the ovule for double fertilization. Angiosperms have evolved a number of hurdles along the pollen tube journey to prevent inbreeding and fertilization by alien sperm cells, and to maximize reproductive success. These pre-zygotic hybridization barriers require intensive communication between the male and female reproductive cells and the necessity to distinguish self from non-self interaction partners. General molecules such as nitric oxide (NO) or gamma-aminobutyric acid (GABA) therefore appear to play only a minor role in these species-specific communication events. The past 20 years have shown that highly polymorphic peptides play a leading role in all communication steps along the pollen tube pathway and fertilization. Here we review our current understanding of the role of peptides during reproduction with a focus on peptide signalling during self-incompatibility, pollen tube growth and guidance as well as sperm reception and gamete activation. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  15. SEISMIC RESISTING PERFORMANCE OF A NEW DOUBLE TUBE HYBRID SYSTEM FOR MULTI-STORY BUILDINGS

    OpenAIRE

    Nasruddin

    2012-01-01

    Investigation on Double Tube Hybrid System (DTHS) through experimental work and analytical study are conducted as a part of the proposal on the seismic design method for Double Tubes Hybrid System (DTHS) for buildings. This structural system comprises Energy Dissipation Structural Walls (EDSW) as the interior tube and Spandrel Wall Frame (SWF) as the exterior tube. EDSW is composed of two reinforced concrete walls linked by steel coupling girders. The RC walls are not anchored to the foundati...

  16. Vascular lumen formation.

    Science.gov (United States)

    Lammert, Eckhard; Axnick, Jennifer

    2012-04-01

    The vascular system developed early in evolution. It is required in large multicellular organisms for the transport of nutrients, oxygen, and waste products to and from tissues. The vascular system is composed of hollow tubes, which have a high level of complexity in vertebrates. Vasculogenesis describes the de novo formation of blood vessels, e.g., aorta formation in vertebrate embryogenesis. In contrast, angiogenesis is the formation of blood vessels from preexisting ones, e.g., sprouting of intersomitic blood vessels from the aorta. Importantly, the lumen of all blood vessels in vertebrates is lined and formed by endothelial cells. In both vasculogenesis and angiogenesis, lumen formation takes place in a cord of endothelial cells. It involves a complex molecular mechanism composed of endothelial cell repulsion at the cell-cell contacts within the endothelial cell cords, junctional rearrangement, and endothelial cell shape change. As the vascular system also participates in the course of many diseases, such as cancer, stroke, and myocardial infarction, it is important to understand and make use of the molecular mechanisms of blood vessel formation to better understand and manipulate the pathomechanisms involved.

  17. Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors

    Science.gov (United States)

    Du, B. Y.

    2016-10-01

    Pulse tube refrigerators have demonstrated many advantages with respect to temperature stability, vibration, reliability and lifetime among cryo-coolers for detectors. Double-inlet type pulse tube refrigerators are popular in GM type pulse tube refrigerators. The single double-inlet valve may introduce DC flow in refrigerator, which deteriorates the performance of pulse tube refrigerator. One new type of DC control mode is introduced in this paper. Two parallel-placed needle valves with opposite direction named double-valve configuration, instead of single double-inlet valve, are used in our experiment to reduce the DC flow. With two double-inlet operating, the lowest cold end temperature of 18.1K and a coolant of 1.2W@20K have been obtained. It has proved that this method is useful for controlling DC flow of the pulse tube refrigerators, which is very important to understand the characters of pulse tube refrigerators for detectors.

  18. Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis

    Directory of Open Access Journals (Sweden)

    Basma Abbas Abdulmajeed

    2015-01-01

    Full Text Available This study concerns a new type of heat exchangers, which is that of shell-and-double concentric tube heat exchangers. The case studies include both design calculations and performance calculations. The new heat exchanger design was conducted according to Kern method. The volumetric flow rates were 3.6 m3/h and 7.63 m3/h for the hot oil and water respectively. The experimental parameters studied were: temperature, flow rate of hot oil, flow rate of cold water and pressure drop. A comparison was made for the theoretical and experimental results and it was found that the percentage error for the hot oil outlet temperature was (- 1.6%. The percentage errors for the pressure drop in the shell and in the concentric tubes were (17.2% and (- 39% respectively. For cold water outlet temperature, the percentage error was (- 3.3%, while it was (18% considering the pressure drop in the annulus formed. The percentage error for the total power consumed was (-10.8% A theoretical comparison was made between the new design and the conventional heat exchanger from the point of view of, length, mass, pressure drop and total power consumed.

  19. Entropy Generation of Shell and Double Concentric Tubes Heat Exchanger

    Directory of Open Access Journals (Sweden)

    basma abbas abdulmajeed

    2016-06-01

    Full Text Available Entropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger. Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Finally, in order to keep up with modern technology, infrared thermography camera was used in order to measure the temperatures. The entropy generation was determined with lower values when infrared thermography camera was used to measure the temperatures, compared with the values obtained by using thermocouples.

  20. Analysis of prestressed double-wall tubing for LMFBR steam generators

    International Nuclear Information System (INIS)

    Uber, C.F.; Langford, P.J.

    1981-01-01

    A radial interface pressure is provided between the inner and outer tubes of each double-wall tube in a steam generator design now being developed for commercial breeder reactor plants. This paper describes a finite element analysis of the manufacturing technique used to prestress the double-wall tube. The analytical predictions are compared with experimental measurements of the residual interface pressure. Resulting residual stress states are used as the starting point for operating condition analyses. 9 refs

  1. Current Status on the Development of a Double Wall Tube Steam Generator

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ho Yun; Choi, Byoung Hae; Kim, Jong Man; Kim, Byung Ho

    2007-12-15

    A fast reactor, which uses sodium as a coolant, has a lot of merits as a next generation nuclear reactor. However, the possibility of a sodium-water reaction occurrence hinders the commercialization of this reactor. As one way to improve the reliability of a steam generator, a double-wall tube steam generator is being developed in GEN-4 program. In this report, the current state of the technical developments for a double-wall tube steam generator are reviewed and a future plan for the development of a double-wall tube steam generator is established. The current focuses of this research are an improvement of the heat transfer capability for a double-wall tube and the development of a proper leak detection method for the failure of a double-wall tube during a reactor operation. The ideal goal is an on-line leak detection of a double wall tube to prevent the sodium-water reaction. However, such a method is not developed as yet. An alternative method is being used to improve the reliability of a steam generator by performing a non-destructive test of a double wall tube during the refueling period of a reactor. In this method a straight double wall tube is employed to perform this test easily, but has a difficulty regarding an absorption of a thermal expansion of the used materials. If an on-line leak detection method is developed, the demerits of a straight double-wall tube are avoided by using a helical type double-wall tube, and the probability of a sodium-water reaction can be reduced to a level less than the design-based accident.

  2. Development of a helical-coil double wall tube steam generator for 4S reactor

    International Nuclear Information System (INIS)

    Kitajima, Yuko; Maruyama, Shigeki; Jimbo, Noboru; Hino, Takehisa; Sato, Katsuhiko

    2011-01-01

    The 4S, Super-Safe Small and Simple, is a small-sized sodium-cooled fast reactor. A fast reactor usually uses sodium as a coolant to transfer heat from core to turbine/generator system. The heat of the intermediate heat transport system and that of the water stream systems are exchanged by the steam generator (SG) tubes. If the tube failure occurs, a sodium/water reaction could be occurred. To prevent the reaction and enhance safety, a helical-coil-type double wall tube with wire mesh interlayer and continuous monitoring systems of tube failure are applied to the SG of the 4S. The development and general features of this type double wall tube were described in Ref. 1) and Ref. 2). Those paper summarized following results; The tubes studied in these references were straight type. To establish this SG, development of manufacturing method of helical-coil-type double wall tube and validation of the tube failure monitoring system are needed. In this study, three demonstration tests have been performed; welding test of the double wall tube to manufacture the tubes with 70-80m length, assembling test of the helical-coil tube, and confirmation test of the tube processing system using the fabricated helical-coil tubes. As a result, following technologies have been successfully established. (1) Development of the welding techniques for manufacturing of the helical-coil-type double wall tube with wire mesh interlayer. (2) The confirmation test for manufacturing the helical coil tube of the SG. (author)

  3. Analysis of the heat transfer in double and triple concentric tube heat exchangers

    Science.gov (United States)

    Rădulescu, S.; Negoiţă, L. I.; Onuţu, I.

    2016-08-01

    The tubular heat exchangers (shell and tube heat exchangers and concentric tube heat exchangers) represent an important category of equipment in the petroleum refineries and are used for heating, pre-heating, cooling, condensation and evaporation purposes. The paper presents results of analysis of the heat transfer to cool a petroleum product in two types of concentric tube heat exchangers: double and triple concentric tube heat exchangers. The cooling agent is water. The triple concentric tube heat exchanger is a modified constructive version of double concentric tube heat exchanger by adding an intermediate tube. This intermediate tube improves the heat transfer by increasing the heat area per unit length. The analysis of the heat transfer is made using experimental data obtained during the tests in a double and triple concentric tube heat exchanger. The flow rates of fluids, inlet and outlet temperatures of water and petroleum product are used in determining the performance of both heat exchangers. Principally, for both apparatus are calculated the overall heat transfer coefficients and the heat exchange surfaces. The presented results shows that triple concentric tube heat exchangers provide better heat transfer efficiencies compared to the double concentric tube heat exchangers.

  4. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis

    Directory of Open Access Journals (Sweden)

    Feng Hong

    2015-01-01

    Full Text Available Bacterial nanocellulose (BNC has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine.

  5. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis.

    Science.gov (United States)

    Hong, Feng; Wei, Bin; Chen, Lin

    2015-01-01

    Bacterial nanocellulose (BNC) has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine.

  6. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis

    Science.gov (United States)

    Wei, Bin; Chen, Lin

    2015-01-01

    Bacterial nanocellulose (BNC) has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine. PMID:26090420

  7. Reliability of double-wall-tube steam generator for FBR considering water leak accident frequency

    International Nuclear Information System (INIS)

    Ueda, Nobuyuki; Kinoshita, Izumi; Nishi, Yoshihisa

    2000-01-01

    For early realization, a fast breeder reactor (FBR) is required to reduce construction cost. A reactor concept in which the intermediate heat transport system is eliminated by introducing a double-wall-tube steam generator is one convincing approach. The reliability of the double-wall-tube SG in a water leak accident (sodium-water reaction accident) due to tube failure is strongly related to the mitigating system design. The safety design of the double-wall-tube SG approach is investigated to limit the accident occurrence below 10 -7 (1/ry. A tube-to-tube weld is excluded from the reference design, because the welding process is too difficult and complicated to effectively prevent adhesion of the double-wall-tube. The reliability of the tube-to-tube plate was evaluated at 10 -10 (l/hr) for an inner tube and 10 -9 (l/hr) for an outer with reference to the failure experience of previous SGs. The failure must be detected within 30 to 60 minutes. (author)

  8. Single chest tube drainage is superior to double chest tube drainage after lobectomy: a meta-analysis.

    Science.gov (United States)

    Zhou, Dong; Deng, Xu-Feng; Liu, Quan-Xing; Chen, Qian; Min, Jia-Xin; Dai, Ji-Gang

    2016-05-27

    In this meta-analysis, we conducted a pooled analysis of clinical studies comparing the efficacy of single chest tube versus double chest tube after a lobectomy. According to the recommendations of the Cochrane Collaboration, we established a rigorous study protocol. We performed a systematic electronic search of the PubMed, Embase, Cochrane Library and Web of Science databases to identify articles to include in our meta-analysis. A literature search was performed using relevant keywords. A meta-analysis was performed using RevMan© software. Five studies, published between 2003 and 2014, including 630 patients (314 patients with a single chest tube and 316 patients with a double chest tube), met the selection criteria. From the available data, the patients using a single tube demonstrated significantly decreased postoperative pain [weighted mean difference [WMD] -0.60; 95 % confidence intervals [CIs] -0.68-- 0.52; P tube after a pulmonary lobectomy. However, there were no significant differences in postoperative complications [OR 0.91; 95 % CIs 0.57-1.44; P = 0.67] and re-drainage rates [OR 0.81; 95 % CIs 0.42-1.58; P = 0.54]. Our results showed that a single-drain method is effective, reducing postoperative pain, hospitalization times and duration of drainage in patients who undergo a lobectomy. Moreover, the single-drain method does not increase the occurrence of postoperative complications and re-drainage rates.

  9. Physics of lumen growth.

    Science.gov (United States)

    Dasgupta, Sabyasachi; Gupta, Kapish; Zhang, Yue; Viasnoff, Virgile; Prost, Jacques

    2018-05-22

    We model the dynamics of formation of intercellular secretory lumens. Using conservation laws, we quantitatively study the balance between paracellular leaks and the build-up of osmotic pressure in the lumen. Our model predicts a critical pumping threshold to expand stable lumens. Consistently with experimental observations in bile canaliculi, the model also describes a transition between a monotonous and oscillatory regime during luminogenesis as a function of ion and water transport parameters. We finally discuss the possible importance of regulation of paracellular leaks in intercellular tubulogenesis.

  10. Experimental facility design for a gap heat transfer in a double wall tube

    International Nuclear Information System (INIS)

    Nam, Ho Yun; Hong, Jong Gan; Kim, Jong Man; Kim, Jong Bum; Jeong, Ji Young

    2012-01-01

    A reliable steam generator design is one of the most critical issues in developing a sodium cooled fast reactor (SFR), and various efforts to avoid potential sodium water reaction (SWR) have been made. For this reason, SFR steam generators have been developed to improve its reliability using a double wall tube (DWT), which has two barriers between the sodium and water. Most steam generators for SFRs are the shell and tube type. Steam at high pressure and low temperature flows inside the inner tubes, which are heated by the shell side sodium at low pressure and high temperature. Since the inner and outer tubes of conventional DWTs are made of identical materials, the degree of thermal expansion is somewhat different between the two concentric tubes owing to their temperature difference. Therefore, a greater temperature difference results in less contact pressures between the inner and outer tubes. This feature results in a deterioration of the heat transfer capability of DWTs. Current developments are focused on an improvement of heat transfer capability by investigating the gap conductance between the two concentric tubes. To improve the heat transfer capability of DWTs, it is preferable to use different tube materials (Fig. 1). It is recommended to choose the inner tube material whose thermal expansion coefficient is greater than that of the outer tube by 10 to 15%

  11. Study on drop pressure and flow distribution of double-tube heat exchanger

    International Nuclear Information System (INIS)

    Liu Junqiang; Chen Minghui; Hu Yumin; Li Rizhu; Kong Dechun; Zhang Weijie

    2007-01-01

    The parallel connection channel pressure drop characters of the double-tube bundle heat exchange were experimentally investigated in this paper in order to find out how the flow of the heat exchanger is distributed and then to optimize the structure of heat exchanger according to the flow distribution. A double-tube bundle heat exchanger was built according to the similarity criteria. The experiment system was also built to test the optimization of the heat exchanger. The experiment results reveal that the calculating model is reliable and decreasing pipe space to optimize the heat exchanger is reasonable. (authors)

  12. Chapter 16 Lumen Modification

    Science.gov (United States)

    Rebecca E. Ibach; Roger M. Rowell

    2012-01-01

    When wood is vacuum impregnated with liquid vinyl monomers that do not swell wood, and then in situ polymerized either by chemical catalyst-heat, or gamma radiation, the polymer is located almost solely in the lumens of the wood. Figure 16.1 is a scanning electron microscopy (SEM) micrograph of unmodified wood showing open cells that are...

  13. Double tube heat exchanger with novel enhancement: Part I - flow development length and adiabatic friction factor

    Energy Technology Data Exchange (ETDEWEB)

    Tiruselvam, R.; Raghavan, Vijay R. [Universiti Teknologi PETRONAS, Faculty of Mechanical Engineering, Tronoh (Malaysia)

    2012-04-15

    The study is conducted to evaluate the flow characteristics in a double tube heat exchanger using two new and versatile enhancement configurations. The novelty is that they are usable in single phase forced convection, evaporation and condensation. Correlations are proposed for flow development length and friction factor for use in predicting fluid pumping power in thermal equipment as well as in subsequent heat transfer characterization of the surface. (orig.)

  14. Description of a double centrifugation tube method for concentrating canine platelets

    OpenAIRE

    Perazzi, Anna; Busetto, Roberto; Martinello, Tiziana; Drigo, Michele; Pasotto, Daniela; Cian, Francesco; Patruno, Marco; Iacopetti, Ilaria

    2013-01-01

    Background To evaluate the efficiency of platelet-rich plasma preparations by means of a double centrifugation tube method to obtain platelet-rich canine plasma at a concentration at least 4 times higher than the baseline value and a concentration of white blood cells not exceeding twice the reference range. A complete blood count was carried out for each sample and each concentrate. Whole blood samples were collected from 12 clinically healthy dogs (consenting blood donors). Blood was proces...

  15. Investigation of FIV Characteristics on a Coaxial Double-tube Structure

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kee Nam; Kim, Yong Wan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Sang Chul [ABLEMAX Co., Seoul (Korea, Republic of)

    2009-10-15

    A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of 950 .deg. C for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

  16. Evaluation of single and double centrifugation tube methods for concentrating equine platelets.

    Science.gov (United States)

    Argüelles, D; Carmona, J U; Pastor, J; Iborra, A; Viñals, L; Martínez, P; Bach, E; Prades, M

    2006-10-01

    The aim of this study was to evaluate single and double centrifugation tube methods for concentrating equine platelets. Whole blood samples were collected from clinically normal horses and processed by use of single and double centrifugation tube methods to obtain four platelet concentrates (PCs): PC-A, PC-B, PC-C, and PC-D, which were analyzed using a flow cytometry hematology system for hemogram and additional platelet parameters (mean platelet volume, platelet distribution width, mean platelet component concentration, mean platelet component distribution width). Concentrations of transforming growth factor beta 1 (TGF-beta(1)) were determined in all the samples. Platelet concentrations for PC-A, PC-B, PC-C, and PC-D were 45%, 44%, 71%, and 21% higher, respectively, compared to the same values for citrated whole blood samples. TGF-beta(1) concentrations for PC-A, PC-B, PC-C, and PC-D were 38%, 44%, 44%, and 37% higher, respectively, compared to citrated whole blood sample values. In conclusion, the single and double centrifugation tube methods are reliable methods for concentrating equine platelets and for obtaining potentially therapeutic TGF-beta(1) levels.

  17. Description of a double centrifugation tube method for concentrating canine platelets.

    Science.gov (United States)

    Perazzi, Anna; Busetto, Roberto; Martinello, Tiziana; Drigo, Michele; Pasotto, Daniela; Cian, Francesco; Patruno, Marco; Iacopetti, Ilaria

    2013-07-22

    To evaluate the efficiency of platelet-rich plasma preparations by means of a double centrifugation tube method to obtain platelet-rich canine plasma at a concentration at least 4 times higher than the baseline value and a concentration of white blood cells not exceeding twice the reference range. A complete blood count was carried out for each sample and each concentrate. Whole blood samples were collected from 12 clinically healthy dogs (consenting blood donors). Blood was processed by a double centrifugation tube method to obtain platelet concentrates, which were then analyzed by a flow cytometry haematology system for haemogram. Platelet concentration and white blood cell count were determined in all samples. Platelet concentration at least 4 times higher than the baseline value and a white blood cell count not exceeding twice the reference range were obtained respectively in 10 cases out of 12 (83.3%) and 11 cases out of 12 (91.6%). This double centrifugation tube method is a relatively simple and inexpensive method for obtaining platelet-rich canine plasma, potentially available for therapeutic use to improve the healing process.

  18. Experimental study for transient response of a double-tube thermosyphon (DTTH)

    International Nuclear Information System (INIS)

    Salem, M.A.M.

    2010-01-01

    Energy conservation is becoming increasingly important as the cost of fuel continuously rises. The heat pipe and the closed two-phase thermosyphon are particularly effective tools in the heat transfer process.A theoretical and experimental investigation was conducted to study the double-tube two-phase closed-thermosyphon (DTTH) behavior in transient regimes. Experiments were performed to investigate the effects of changing the heating and cooling rate as well as the evaporator length on the double tube thermosyphon in actual integrated operation (start-up, steady-state and shut-down). he necessity for a dynamic model of DTTH for some applications of discontinuous operation imposed the need to the current applied investigation. Therefore, the main objective of the current study is to develop a theoretical model that can predict the dynamic behavior of the double-tube evaporator by tracing various transient parameters during operation from start up to steady state until shut down condition. A model describing both thermal and phase flows of the closed two-phase double tube thermosyphon (DTTH) has been simulated. The theoretical model provides a general description of the behavior of our practical setup based on experimental observations which show a simple exponential behavior. It is based on a two thermal body description (evaporator wall and working fluid) there is good agreement between experiments data and numerical prediction.A computer simulation program based on the method was developed to estimate temperature and the other performance of double tube thermosyphon as well as the time needed to reach steady state condition. The governing equations of the simple 1-D model were solved by Engineering Equation Solver program (EES) using finite difference Euler method. A computer program is designed to solve these differential equations by an explicit finite difference method. The results from this model were found to be in general agreement with the experimental

  19. Study on the structure optimization scheme design of a double-tube once-through steam

    International Nuclear Information System (INIS)

    Wei, Xinyu; Wu, Shifa; Wang, Pengfei; Zhao, Fuyu

    2016-01-01

    A double-tube once-through steam generator (DOTSG) consisting of an outer straight tube and an inner helical tube is studied in this work. First, the structure of the DOTSG is optimized by considering two different objective functions. The tube length and the total pressure drop are considered as the first and second objective functions, respectively. Because the DOTSG is divided into the subcooled, boiling, and superheated sections according to the different secondary fluid states, the pitches in the three sections are defined as the optimization variables. A multi-objective optimization model is established and solved by particle swarm optimization. The optimization pitch is small in the subcooled region and superheated region, and large in the boiling region. Considering the availability of the optimum structure at power levels below 100% full power, we propose a new operating scheme that can fix the boundaries between the three heat-transfer sections. The operation scheme is proposed on the basis of data for full power, and the operation parameters are calculated at low power level. The primary inlet and outlet temperatures, as well as flow rate and secondary outlet temperature are changed according to the operation procedure

  20. Male-female crosstalk during pollen germination, tube growth and guidance, and double fertilization.

    Science.gov (United States)

    Dresselhaus, Thomas; Franklin-Tong, Noni

    2013-07-01

    Sperm cells of flowering plants are non-motile and thus require transportation to the egg apparatus via the pollen tube to execute double fertilization. During its journey, the pollen tube interacts with various sporophytic cell types that support its growth and guide it towards the surface of the ovule. The final steps of tube guidance and sperm delivery are controlled by the cells of the female gametophyte. During fertilization, cell-cell communication events take place to achieve and maximize reproductive success. Additional layers of crosstalk exist, including self-recognition and specialized processes to prevent self-fertilization and consequent inbreeding. In this review, we focus on intercellular communication between the pollen grain/pollen tube including the sperm cells with the various sporophytic maternal tissues and the cells of the female gametophyte. Polymorphic-secreted peptides and small proteins, especially those belonging to various subclasses of small cysteine-rich proteins (CRPs), reactive oxygen species (ROS)/NO signaling, and the second messenger Ca(2+), play center stage in most of these processes.

  1. Study on the structure optimization scheme design of a double-tube once-through steam

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Xinyu; Wu, Shifa; Wang, Pengfei; Zhao, Fuyu [Dept. of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an (China)

    2016-08-15

    A double-tube once-through steam generator (DOTSG) consisting of an outer straight tube and an inner helical tube is studied in this work. First, the structure of the DOTSG is optimized by considering two different objective functions. The tube length and the total pressure drop are considered as the first and second objective functions, respectively. Because the DOTSG is divided into the subcooled, boiling, and superheated sections according to the different secondary fluid states, the pitches in the three sections are defined as the optimization variables. A multi-objective optimization model is established and solved by particle swarm optimization. The optimization pitch is small in the subcooled region and superheated region, and large in the boiling region. Considering the availability of the optimum structure at power levels below 100% full power, we propose a new operating scheme that can fix the boundaries between the three heat-transfer sections. The operation scheme is proposed on the basis of data for full power, and the operation parameters are calculated at low power level. The primary inlet and outlet temperatures, as well as flow rate and secondary outlet temperature are changed according to the operation procedure.

  2. Anharmonic properties of Raman modes in double wall carbon nano tubes

    Energy Technology Data Exchange (ETDEWEB)

    Marquina, J. [Universidad de los Andes, Facultad de Ciencias, Centro de Estudios Avanzados en Optica, 5101 Merida (Venezuela, Bolivarian Republic of); Power, Ch.; Gonzalez, J. [Universidad de los Andes, Facultad de Ciencias, Centro de Estudios en Semiconductores, 5101 Merida (Venezuela, Bolivarian Republic of); Broto, J. M. [Universite de Toulouse, Laboratoire National des Champs Magnetiques Intenses, CNRS UPR 3228, 31400 Toulouse (France); Flahaut, E., E-mail: castella@ula.v [Universite Paul Sabatier, Laboratoire de Chimie des Materiaux Inorganiques, UMR CNRS 5085, 31062 Toulouse (France)

    2011-07-01

    The temperature dependence of the radial breathing modes (RB Ms) and the zone-center tangential optical phonons (G-bands) of double-walled carbon nano tubes has been investigated between 300 and 700 K using Raman scattering. As expected, with increasing temperature, the frequencies of the Raman peaks, including the RB Ms and G-bands downshift simultaneously. We show here that the temperature dependence of the RB Ms can be fitted by a simple linear dependence and different RB Ms have different frequency shifts. We observe a noticeable nonlinearity in the temperature dependence of the G-band associated with the outer semiconducting tube G+ext (s). The deviation from the linear trend is due to the contribution of the third-order anharmonic term in the lattice potential energy with a pure temperature effect. An estimated value of 1.5 for the Grueneisen parameter of the G+ext (s) band was found. (Author)

  3. Double plasma arc in a graphite tube - application of discharge atmospheres

    International Nuclear Information System (INIS)

    Arens, C.; Nickel, H.; Mazurkiewicz, M.; Vukanovic, D.

    1981-01-01

    With a view to safety and economic efficiency element-specific limits are required for permissible impurities in reactor graphite. This leads to the necessity of developing suitable methods of analysis. Emission spectroscopy has proved to be a method of analysis featuring a high detection capability and offering the possibility of determining several elements simultaneously. A prolongation of the particle residence time in the plasma (and, thus, an increase in radiation intensity) was the objective when developing a novel spectrochemical source of excitation. The method uses two d.c. arcs burning in a horizontally arranged graphite tube. The double plasma arc in a graphite tube has proved to be an excellent source of excitation for the analysis of powder and solutions. (orig./IHOE)

  4. Parametric study and performance analysis of hybrid rocket motors with double-tube configuration

    Science.gov (United States)

    Yu, Nanjia; Zhao, Bo; Lorente, Arnau Pons; Wang, Jue

    2017-03-01

    The practical implementation of hybrid rocket motors has historically been hampered by the slow regression rate of the solid fuel. In recent years, the research on advanced injector designs has achieved notable results in the enhancement of the regression rate and combustion efficiency of hybrid rockets. Following this path, this work studies a new configuration called double-tube characterized by injecting the gaseous oxidizer through a head end injector and an inner tube with injector holes distributed along the motor longitudinal axis. This design has demonstrated a significant potential for improving the performance of hybrid rockets by means of a better mixing of the species achieved through a customized injection of the oxidizer. Indeed, the CFD analysis of the double-tube configuration has revealed that this design may increase the regression rate over 50% with respect to the same motor with a conventional axial showerhead injector. However, in order to fully exploit the advantages of the double-tube concept, it is necessary to acquire a deeper understanding of the influence of the different design parameters in the overall performance. In this way, a parametric study is carried out taking into account the variation of the oxidizer mass flux rate, the ratio of oxidizer mass flow rate injected through the inner tube to the total oxidizer mass flow rate, and injection angle. The data for the analysis have been gathered from a large series of three-dimensional numerical simulations that considered the changes in the design parameters. The propellant combination adopted consists of gaseous oxygen as oxidizer and high-density polyethylene as solid fuel. Furthermore, the numerical model comprises Navier-Stokes equations, k-ε turbulence model, eddy-dissipation combustion model and solid-fuel pyrolysis, which is computed through user-defined functions. This numerical model was previously validated by analyzing the computational and experimental results obtained for

  5. A study on the FIV characteristics of a coaxial double-tube under counter flow

    Energy Technology Data Exchange (ETDEWEB)

    Song, K. N.; Kim, Y. W. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, S. C. [ABLEMAX, Seoul (Korea, Republic of)

    2009-07-01

    A VHTR of 200 MWt that produces heat at temperatures in the order of 950 .deg. C is being considered for the nuclear hydrogen system at KAERI. A structural pre-sizing for the coaxial double-tube type cross vessel was carried out to modulate a Flow-Induced Vibration (FIV) and a Fluid-Structure Interaction (FSI) analysis has been carried our using the ADINA code. When compared the FIV characteristics of the proposed design cases by an FSI interaction, and it was found that maximum displacements of the HGD structure are mainly affected by the flow velocity rather than the structural stiffness.

  6. Pyeloplasty for hydronephrosis: Issues of double J stent versus nephrostomy tube as drainage technique

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Garg

    2015-01-01

    Full Text Available Aims: To compare the efficacy, complications, cost analysis and hospital stay between two methods of drainage of the kidney: double J (DJ stent versus nephrostomy tube following open pyeloplasty for ureteropelvic junction obstruction hydronephrosis. Patients and Methods: This was a prospective randomized study of 20 patients in each group over 14 months. Pre and post-operative (3 months function and drainage were assessed by ethylenedicysteine scan and intravenous urogram. Results: Both groups showed similar good improvement in function and drainage. Nephrostomy group had significantly longer hospital stay (P < 0.001 but incurred less cost. Complications with nephrostomy included tube breakage (n = 1 and urine leak after tube removal (n = 2. DJ stents were associated with stent migration (n = 4, increased frequency of micturition (n = 9, dysuria (n = 4 and urinary tract infection (n = 1. Conclusion: Both methods of drainage did not interfere with improvement after pyeloplasty. Minor complications were more with DJ stent (P = 0.0003. Although overall cost of treatment was more with stents, they reduced length of hospital stay. Optimal length of stent is essential to reduce complications secondary to migration and bladder irritation.

  7. CFD simulation and experimental validation of a GM type double inlet pulse tube refrigerator

    Science.gov (United States)

    Banjare, Y. P.; Sahoo, R. K.; Sarangi, S. K.

    2010-04-01

    Pulse tube refrigerator has the advantages of long life and low vibration over the conventional cryocoolers, such as GM and stirling coolers because of the absence of moving parts in low temperature. This paper performs a three-dimensional computational fluid dynamic (CFD) simulation of a GM type double inlet pulse tube refrigerator (DIPTR) vertically aligned, operating under a variety of thermal boundary conditions. A commercial computational fluid dynamics (CFD) software package, Fluent 6.1 is used to model the oscillating flow inside a pulse tube refrigerator. The simulation represents fully coupled systems operating in steady-periodic mode. The externally imposed boundary conditions are sinusoidal pressure inlet by user defined function at one end of the tube and constant temperature or heat flux boundaries at the external walls of the cold-end heat exchangers. The experimental method to evaluate the optimum parameters of DIPTR is difficult. On the other hand, developing a computer code for CFD analysis is equally complex. The objectives of the present investigations are to ascertain the suitability of CFD based commercial package, Fluent for study of energy and fluid flow in DIPTR and to validate the CFD simulation results with available experimental data. The general results, such as the cool down behaviours of the system, phase relation between mass flow rate and pressure at cold end, the temperature profile along the wall of the cooler and refrigeration load are presented for different boundary conditions of the system. The results confirm that CFD based Fluent simulations are capable of elucidating complex periodic processes in DIPTR. The results also show that there is an excellent agreement between CFD simulation results and experimental results.

  8. A Study of Free-Piston Double-Diaphragm Drivers for Expansion Tubes. Report 1

    Science.gov (United States)

    Kendall, M. A.

    1997-01-01

    In recent years the free-piston double-diaphragm driver has been used to increase the performance of the XI pilot expansion tube to super-orbital test conditions. However, the actual performance of the double-diaphragm driver was found to be considerably less than ideal. An experimental study of the double-diaphragm driver was carried out on the XI facility over a range of conditions with the objective of determining the effect of. heat losses; and the non-ideal rupture of the 'light' secondary diaphragm on the driver performance. The disparity between the theoretical and measured performance envelope are highlighted. A viscous limit for the experiments vas established. Heat transfer behind the primary shock is shown to be the mechanism behind this limit Incident, reflected and transmitted shock trajectories for the secondary diaphragm were experimentally determined and compared with computed trajectories from a one-dimensional diaphragm inertia model. It was found that the diaphragm did influence the unsteady expansion. A good agreement between experimental and computed shock trajectories was obtained using a diaphragm inertia model assuming that the diaphragm mass became negligible 3 microns after shock impact.

  9. Petrology and geochemistry of VLT glasses from double drive tube 79001/2

    Science.gov (United States)

    Wentworth, Susan J.; Lindstrom, D. J.; Martinez, R. R.; Mckay, D. S.

    1993-01-01

    As a part of more general studies of soils from Apollo 17 double drive tube 79001/2, glasses from the 79001/2 core are being analyzed by a multidisciplinary approach including SEM/EDS and INAA. Efforts are currently focused on VLT (very low-Ti; TiO2 less than 1 wt%) mare glasses, which are common in 79001/2 and have also been found in other Apollo 17 soils. One of the primary objectives is to determine whether any or all of the Apollo 17 VLT glasses represent pristine volcanic compositions. In addition, the range of VLT glass compositions and possible relationships between the glasses and VLT lithic samples, for which some geochemical data have been obtained previously, is being defined.

  10. Performance improvements of the BNC tubes from unique double-silicone-tube bioreactors by introducing chitosan and heparin for application as small-diameter artificial blood vessels.

    Science.gov (United States)

    Li, Xue; Tang, Jingyu; Bao, Luhan; Chen, Lin; Hong, Feng F

    2017-12-15

    In order to improve property of bacterial nano-cellulose (BNC) to achieve the requirements of clinical application as small caliber vascular grafts, chitosan (CH) was deposited into the fibril network of the BNC tubes fabricated in unique Double-Silicone-Tube bioreactors. Heparin (Hep) was then chemically grafted into the BNC-based tubes using EDC/NHS crosslinking to improve performance of anticoagulation and endothelialization. Physicochemical and mechanical property, blood compatibility, and cytocompatibility were compared before and after compositing. The results indicated that strength at break was increased but burst pressure decreased slightly after compositing. Performance of the BNC tubes was improved remarkably after introducing chitosan and heparin. The EDC/NHS crosslinking catalyzed both amide bonds and ester bonds formation in the BNC/CH-Hep composites. Three-dimensional surface structure and roughness were firstly obtained and discussed in relation to the hemocompatibility of BNC-based tubes. This work demonstrates the heparinized BNC-based tubes have great potential in application as small-diameter vascular prosthesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Structural Pre-sizing of a Coaxial Double-tube Type Hot Gas Duct

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kee Nam; Kim, Y-W [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-10-15

    The nuclear hydrogen system being researched at KAERI is planning to produce hydrogen in the order of 950 .deg. C by using nuclear energy and a thermo-chemical process, and helium gas is tentatively considered as the choice for the coolant. A hot gas duct (HGD) is a key component connecting the reactor pressure vessel and the intermediate heat exchanger (IHX) for the nuclear hydrogen system. The HGD is a unique component exclusively found in an HTR-module concept where a nuclear core and IHX are placed separately into two pressure vessels, which require a connecting duct between them. A coaxial double-tube type cross vessel is considered for the HGD structure of the nuclear hydrogen system because of its successive extensive experience. In this study, a structural pre-sizing for the primary HGD was carried out. These activities include a predecision on the geometric dimensions, a pre-evaluation on the strength, and a pre-selection on the material of the coaxial double-tube type cross vessel components. A predecision on the geometric dimensions was undertaken based on various engineering concepts, such as a constant flow velocity (CFV) model, a constant flow rate (CFR) model, a constant hydraulic head (CHH) model, and finally a heat balanced (HB) model. For the CFV model, CFR model, and CHH model, the HGD structure might be insensitive to a flow induced vibration (FIV) in the case where there are no pressure differences between the hot and cold helium regions. Also we compared the geometric dimensions from the various models.

  12. Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Milnes, J. S., E-mail: james.milnes@photek.co.uk; Conneely, T. M. [Photek Ltd., 26 Castleham Road, St Leonards on Sea, East Sussex TN38 9NS (United Kingdom); Horsfield, C. J. [AWE Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom)

    2016-11-15

    Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 10{sup 3} to 10{sup 4} for the single and 10{sup 4} to 10{sup 6} for the double. We have shown that the saturation level of ∼1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.

  13. Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles

    International Nuclear Information System (INIS)

    Pourahmad, Saman; Pesteei, S.M.

    2016-01-01

    Highlights: • Double tube heat exchanger equipped with wavy strip turbulators was studied. • The effects of wavy strip angles on the effectiveness were investigated. • Variation of the effectiveness with hot and cold water flow rate was presented. • The effectiveness increases with the decrease of wavy strip angle. • The friction factor increases with the decrease of wavy strip angle. - Abstract: In the present study, effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles were experimentally studied. Moreover, variation of the effectiveness with hot water Reynolds numbers for different cold water flow rates were presented. These turbulators with different angles of 45°, 60°, 90°, 120° and 150° were made of galvanized plates with thickness of 1 mm and were installed in the inner tube of heat exchanger. The experiments were carried out at Reynolds numbers of 3000–13,500 at turbulent flow regime. Throughout the experiments, hot and cold water flowed through the inner pipe and the space between the pipes (annulus), respectively. It was tried to keep the inlet hot and cold water temperatures at constant values. Effectiveness-NTU analyses were made for the conditions with and without wavy strips including their different angles and compared to each other. Results showed the considerable effect of turbulators on effectiveness (ε) and number of heat transfer units (NTU) of double tube heat exchanger. In addition, some empirical correlations expressing the results were also developed based on curve fitting.

  14. A Eutectic Melting Study of Double Wall Cladding Tubes of FeCrAl and Zircaloy-4

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Woojin; Son, Seongmin; Lee, You Ho; Lee, Jeong Ik; Ryu, Ho Jin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Jeong, Eun [Kyunghee University, Yongin (Korea, Republic of)

    2015-10-15

    The eutectic melting behavior of FeCrAl/Zircaloy-4 double wall cladding tubes was investigated by annealing at various temperatures ranging from 900 .deg. C to 1300 .deg. C. It was found that significant eutectic melting occurred after annealing at temperatures equal to or higher than 1150 .deg. C. It means that an additional diffusion barrier layer is necessary to limit the eutectic melting between FeCrAl and Zircaloy-4 alloy cladding tubes. Coating of FeCrAl layers on the Zr alloy cladding tube is being investigated for the development of accident tolerant fuel by exploiting of both the oxidation resistance of FeCrAl alloys and the neutronic advantages of Zr alloys. Coating of FeCrAl alloys on Zr alloy cladding tubes can be performed by various techniques including thermal spray, laser cladding, and co-extrusion. Son et al. also reported the fabrication of FeCrAl/Zr ally double wall cladding by the shrink fit method. For the double layered cladding tubes, the thermal expansion mismatch between the dissimilar materials, severe deformation or mechanical failure due to the evolution of thermal stresses can occur when there is a thermal cycling. In addition to the thermal stress problems, chemical compatibilities between the two different alloys should be investigated in order to check the stability and thermal margin of the double wall cladding at a high temperature. Generally, it is considered that Zr alloy cladding will maintain its mechanical integrity up to 1204 .deg. C (2200 .deg. F) to satisfy the acceptance criteria for emergency core cooling systems.

  15. Irradiation stratigraphy and depositional history of the Apollo 16 double drive tube 60009/10

    Science.gov (United States)

    Blanford, G. E.; Blanford, J.; Hawkins, J. A.

    1979-01-01

    We report track density frequency distributions, the fraction of high density grains and minimum track densities for 63, 1 mm wide locations in the Apollo 16 double drive tube 60009/10. From these data we conclude that there are seven irradiation strata in the core. Only one buried reworking zone extending from 50-52 cm was found and it was exposed near the surface from 4.5-9 times 10 to the 6th y with a most probable exposure period of 6 times 10 to the 6th y. There is lack of conclusive data that this zone represents a reworking zone in which case the material below 52 cm most probably was exposed in situ for 4.5 times 10 to the 6th y and developed a reworking zone approximately less than 0.5 cm. The present surface of the core has a reworking zone of 12-13 cm which was exposed from 1.3 times 10 to the 7th to 2.5 times 10 to the 8th y. The best estimate for this exposure period remains the value of approximately less than 1.25 times 10 to the 8th y determined by Bogard and Hirsch (1976). The other strata in the core appear to contain mixtures of various soil types and are not related to in situ depositional events.

  16. Enlargement of halloysite clay nanotube lumen by selective etching of aluminum oxide.

    Science.gov (United States)

    Abdullayev, Elshad; Joshi, Anupam; Wei, Wenbo; Zhao, Yafei; Lvov, Yuri

    2012-08-28

    Halloysite clay tubes have 50 nm diameter and chemically different inner and outer walls (inner surface of aluminum oxide and outer surface of silica). Due to this different chemistry, the selective etching of alumina from inside the tube was realized, while preserving their external diameter (lumen diameter changed from 15 to 25 nm). This increases 2-3 times the tube lumen capacity for loading and further sustained release of active chemical agents such as metals, corrosion inhibitors, and drugs. In particular, halloysite loading efficiency for the benzotriazole increased 4 times by selective etching of 60% alumina within the tubes' lumens. Specific surface area of the tubes increased over 6 times, from 40 to 250 m(2)/g, upon acid treatment.

  17. Evaluation on double-wall-tube residual stress distribution of sodium-heated steam generator by neutron diffraction and numerical analysis

    International Nuclear Information System (INIS)

    Kisohara, N.; Suzuki, H.; Akita, K.; Kasahara, N.

    2012-01-01

    A double-wall-tube is nominated for the steam generator heat transfer tube of future sodium fast reactors (SFRs) in Japan, to decrease the possibility of sodium/water reaction. The double-wall-tube consists of an inner tube and an outer tube, and they are mechanically contacted to keep the heat transfer of the interface between the inner and outer tubes by their residual stress. During long term SG operation, the contact stress at the interface gradually falls down due to stress relaxation. This phenomenon might increase the thermal resistance of the interface and degrade the tube heat transfer performance. The contact stress relaxation can be predicted by numerical analysis, and the analysis requires the data of the initial residual stress distributions in the tubes. However, unclear initial residual stress distributions prevent precious relaxation evaluation. In order to resolve this issue, a neutron diffraction method was employed to reveal the tri-axial (radius, hoop and longitudinal) initial residual stress distributions in the double-wall-tube. Strain gauges also were used to evaluate the contact stress. The measurement results were analyzed using a JAEA's structural computer code to determine the initial residual stress distributions. Based on the stress distributions, the structural computer code has predicted the transition of the relaxation and the decrease of the contact stress. The radial and longitudinal temperature distributions in the tubes were input to the structural analysis model. Since the radial thermal expansion difference between the inner (colder) and outer (hotter) tube reduces the contact stress and the tube inside steam pressure contributes to increasing it, the analytical model also took these effects into consideration. It has been conduced that the inner and outer tubes are contacted with sufficient stresses during the plant life time, and that effective heat transfer degradation dose not occur in the double-wall-tube SG. (authors)

  18. Geochemistry of HASP, VLT, and other glasses from double drive tube 79001/2

    Science.gov (United States)

    Lindstrom, D. J.; Wentworth, S. J.; Martinez, R. R.; Mckay, D. S.

    1992-01-01

    The Apollo 17 double drive tube 79001/2 (station 9, Van Serg Crater) is distinctive because of its extreme maturity, abundance, and variety of glass clasts. It contains mare glasses of both high Ti and very low Ti (VLT) compositions, and highland glasses of all compositions common in lunar regolith samples: highland basalt (feldspathic; Al2O3 greater than 23 wt percent), KREEP (Al2O3 less than 23 wt percent, K2O greater than 0.25 wt percent), and low-K Fra Mauro (LKFM; Al2O3 less than 23 wt percent, K2O less than 0.25 wt percent). It also contains rare specimens of high-alumina, silica-poor (HASP), and ultra Mg glasses. HASP glasses contain insufficient SiO2 to permit the calculation of a standard norm, and are thought to be the product of volatilization during impact melting. They have been studied by electron microprobe major-element analysis techniques but have not previously been analyzed for trace elements. The samples analyzed for this study were polished grain mounts of the 90-160 micron fraction of four sieved samples from the 79001/2 core (depth range 2.3-11.5 cm). A total of 80 glasses were analyzed by SEM/EDS and electron microprobe, and a subset of 33 of the glasses, representing a wide range of compositional types, was chosen for high-sensitivity INAA. A microdrilling device removed disks (mostly 50-100 micron diameter, weighing approx. 0.1-0.5 micro-g) for INAA. Preliminary data reported here are based only on short counts done within two weeks of irradiation.

  19. Multi-objective shape optimization of double pipe heat exchanger with inner corrugated tube using RSM method

    International Nuclear Information System (INIS)

    Han, Huai-Zhi; Li, Bing-Xi; Wu, Hao; Shao, Wei

    2015-01-01

    Integrated a fully developing three-dimensional heat transfer and flow model, a multi-objective optimization aims to fulfill the geometric design for double-tube heat exchangers with inner corrugated tube is investigated in this work with RSM. Dimensionless corrugation pitch (p/D), dimensionless corrugation height (H/D), dimensionless corrugation radius (r/D) and Reynolds number (Re) are considered as four design parameters. Considering the process parameters, the characteristic numbers involving heat transfer characteristic, resistance characteristic and overall heat transfer performance calculated by CFD, and are served as objective functions to the RSM (Nu c , f c , Nu c /Nu s , f c /f s and h in this paper). The results of optimal designs are a set of multiple optimum solutions, called 'Pareto optimal solutions'. It reveals the identical tendency of Nu c /Nu s and f c /f s reflecting the conflict between them that means augmenting the heat transfer performance with various design parameters in the optimal situation inevitably sacrificed the increase of flow resistance. According to the Pareto optimal curves, the optimum designing parameters of double pipe heat exchanger with inner corrugated tube under the constrains of Nu c /Nu s ≥1.2 are found to be P/D = 0.82, H/D = 0.22, r/D = 0.23, Re = 26,263, corresponding to the maximum value of η = 1.12. (authors)

  20. Technology of double casing tubes & a binary cycle system for hole cleaning for CBM multi-branch horizontal wells

    Directory of Open Access Journals (Sweden)

    Yong Yang

    2017-03-01

    Full Text Available At present, the aeration-assisted cutting-carrying technology is faced with complexities in the drilling of CBM multi-branch horizontal wells. For example, the aerating pressure is hardly maintained, and the borehole instability may happen. In view of these prominent problems, the technology of double casing tubes & a binary cycle system suitable for CBM multi-branch horizontal wells was developed according to the Venturi principle by means of parasitic tube insufflation which is used for well control simulation system. Then, a multiphase flow finite element model was established for the fluid-cutting particle system in this drilling condition. This technology was tested in field. Double-casing tubes cementing is adopted in this technology and a jet generator is installed at the bottom of the inner casing. In the process of drilling, the drilling fluid injected through double intermediate casing annulus is converted by the jet generator into a high-efficiency steering water jet, which, together with the water jet generated by the bit nozzle, increases the fluid returning rate in the inner annulus space. It is indicated from simulation results that the cutting-carrying effect is the best when the included angle between the nozzle of the jet generator and the vertical direction is 30°. Besides, the influential laws of cutting size, primary cycle volume, accessory cycle volume and drilling velocity on hole cleaning are figured out. It is concluded that this technology increases the flow rate of drilling fluid in annulus space, the returning rate of drilling fluid significantly and the cutting-carrying capacity. It is currently one of the effective hole cleaning technologies for CBM multi-branch horizontal wells where fresh water is taken as the drilling fluid.

  1. Porous double-layer polymer tubing for the potential use in heterogeneous continuous flow reactions.

    Science.gov (United States)

    Herwig, Gordon; Hornung, Christian H; Peeters, Gary; Ebdon, Nicholas; Savage, G Paul

    2014-12-24

    Functional polymer tubing with an OD of 1/16 or 1/8 in. was fabricated by a simple polymer coextrusion process. The tubing was made of an outer impervious polypropylene layer and an inner layer, consisting of a blend of a functional polymer, polyethylene-co-methacrylic acid, and a sacrificial polymer, polystyrene. After a simple solvent leaching step using common organic solvents, the polystyrene was removed, leaving behind a porous inner layer that contains functional carboxylic acid groups, which could then be used for the immobilization of target molecules. Solution-phase reactions using amines or isocyanates have proven successful for the immobilization of a series of small molecules and polymers. This flexible multilayered functional tubing can be easily cut to the desired length and connected via standard microfluidic fittings.

  2. One lung ventilation using double‑lumen tubes: Initial experience ...

    African Journals Online (AJOL)

    2014-05-09

    May 9, 2014 ... The use of DLT for OLV to enhance thoracic anesthetic practice should be .... Prior to our purchase of a pediatric flexible bronchoscope, verification of DLT ... The short duration of action of local anesthetic agents solely ...

  3. Enhancement of distillate output of double basin solar still with vacuum tubes

    OpenAIRE

    Hitesh N. Panchal

    2015-01-01

    In this research paper, attempts are made to make a double basin solar still. The overall size of the lower basin used is 1006 mm × 325 mm × 380 mm and the outer basin is 1006 mm × 536 mm × 100 mm. Black granite gravel is used to increase the distillate output by reducing the quantity of brackish or saline water in both basins. Several experiments have been conducted to determine the performance of a solar still in climate conditions of Mehsana (latitude of 23°59′ and longitude of 72° 38′), G...

  4. Enhancement of heat transfer rate with structural modification of double pipe heat exchanger by changing cylindrical form of tubes into conical form

    International Nuclear Information System (INIS)

    Hashemian, Mehran; Jafarmadar, Samad; Nasiri, Javid; Sadighi Dizaji, Hamed

    2017-01-01

    Highlights: • An improved geometry is presented by changing tubes form into conical. • Enhancement of heat transfer rate is investigated. • Frictional characteristics for novel geometry are studied. • For a proper understanding of the subject, the exact physical interpretation is added. • The effect of flow, geometry and thermodynamic parameters is considered. - Abstract: In this paper, cylindrical tubes of a double pipe heat exchanger were changed into the conical tubes as an innovative design which causes improvement of thermal performance of heat exchanger without increment of its weight. Utilization of conical tube instead of cylindrical tube can impress both thermal and frictional characteristics of heat exchanger. Hence, the effect of conical tubes on Nusselt number, friction factor and thermal performance factor are evaluated in present research which was not covered already. Moreover, the effects of hydrodynamic, thermodynamic and geometrical characteristics are analyzed. All said parameters are numerically investigated for nine different combinations of flow direction and conical tubes geometry. The results of simulations of the said configurations are presented to compare the cases from different points of view and determine the most thermally efficient case. The results reveal modified geometry makes 63% increment in Nu number and 54% increment in heat transfer rate at optimum condition.

  5. Acesso vascular para hemodiálise com cateter temporário de duplo lúmen em cães com insuficiência renal aguda Hemodialysis vascular access with temporary double-lumen catheter in dogs with acute renal failure

    Directory of Open Access Journals (Sweden)

    Alessandra Melchert

    2008-08-01

    Full Text Available A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA, enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD, com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%, devido à obstrução do lúmen do cateter em seis sessões (5,8% ou por saída acidental do mesmo em uma sessão (1,0%. Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.Hemodialysis is a therapeutic procedure that can sustain the patient's life in acute renal failure (ARF, during the renal function recover. To perform hemodialysis (HD, an extracorporeal circulation is established to blood filtration, imposing the need of a viable and efficient vascular access. The aim of this study was to evaluate the effectiveness and complications of the HD vascular access with temporary double-lumen catheter inserted into the external jugular vein. Ten mongrel dogs with ARF, induced by gentamicin administration, were submitted to daily

  6. Flow instability research on steam generator with straight double-walled heat transfer tube for FBR. Pressure drop under high pressure condition

    International Nuclear Information System (INIS)

    Liu, Wei; Tamai, Hidesada; Yoshida, Hiroyuki; Takase, Kazuyuki; Hayafune, Hiroki; Futagami, Satoshi; Kisohara, Naoyuki

    2008-01-01

    For the Steam Generator (SG) with straight double-walled heat transfer tube that used in sodium cooled Faster Breeder Reactor, flow instability is one of the most important items need researching. As the first step of the research, thermal hydraulics experiments were performed under high pressure condition in JAEA with using a straight tube. Pressure drop, heat transfer coefficients and void fraction data were derived. This paper evaluates the pressure drop data with TRAC-BF1 code. The Pffan's correlation for single phase flow and the Martinelli-Nelson's two-phase flow multiplier are found can be well predicted the present pressure drop data under high pressure condition. (author)

  7. 2D double-layer-tube-shaped structure Bi2S3/ZnS heterojunction with enhanced photocatalytic activities

    International Nuclear Information System (INIS)

    Gao, Xiaoming; Wang, Zihang; Fu, Feng; Li, Xiang; Li, Wenhong

    2015-01-01

    Bi 2 S 3 /ZnS heterojunction with 2D double-layer-tube-shaped structures was prepared by the facile synthesis method. The corresponding relationship was obtained among loaded content to phase, morphology, and optical absorption property of Bi 2 S 3 /ZnS composite. The results shown that Bi 2 S 3 loaded could evidently change the crystallinity of ZnS, enhance the optical absorption ability for visible light of ZnS, and improve the morphologies and microstructure of ZnS. The photocatalytic activities of the Bi 2 S 3 /ZnS sample were evaluated for the photodegradation of phenol and desulfurization of thiophene under visible light irradiation. The results showed that Bi 2 S 3 loaded greatly improved the photocatalytic activity of ZnS, and the content of loaded Bi 2 S 3 had an impact on the catalytic activity of ZnS. Moreover, the mechanism of enhanced photocatalytic activity was also investigated by analysis of relative band positions of Bi 2 S 3 and ZnS, and photo-generated hole was main active radicals during photocatalytic oxidation process

  8. 2D double-layer-tube-shaped structure Bi2S3/ZnS heterojunction with enhanced photocatalytic activities

    Science.gov (United States)

    Gao, Xiaoming; Wang, Zihang; Fu, Feng; Li, Xiang; Li, Wenhong

    2015-10-01

    Bi2S3/ZnS heterojunction with 2D double-layer-tube-shaped structures was prepared by the facile synthesis method. The corresponding relationship was obtained among loaded content to phase, morphology, and optical absorption property of Bi2S3/ZnS composite. The results shown that Bi2S3 loaded could evidently change the crystallinity of ZnS, enhance the optical absorption ability for visible light of ZnS, and improve the morphologies and microstructure of ZnS. The photocatalytic activities of the Bi2S3/ZnS sample were evaluated for the photodegradation of phenol and desulfurization of thiophene under visible light irradiation. The results showed that Bi2S3 loaded greatly improved the photocatalytic activity of ZnS, and the content of loaded Bi2S3 had an impact on the catalytic activity of ZnS. Moreover, the mechanism of enhanced photocatalytic activity was also investigated by analysis of relative band positions of Bi2S3 and ZnS, and photo-generated hole was main active radicals during photocatalytic oxidation process.

  9. Observation of double loop insertion of silicone rubber tube anastomosis method combined with "Z" flap repair in the treatment of lacrimal ductule laceration

    Directory of Open Access Journals (Sweden)

    Rui Hou

    2017-03-01

    Full Text Available AIM: To investigate the clinical curative effect of double loop insertion of silicone rubber tube combined with "Z" flap repair in the treatment of laceration of eyelid with canaliculus laceration. METHODS: The paper reviewed 45 cases of laceration of eyelid with laceration canaliculus, caused by trauma, which were treated in my hospital from January 2014 to January 2016. In the process of anastomosis of lacrimal duct and suture of eyelid laceration, either the method of single spinal anesthesia tube placement on skin contraposition suture or the method of dual annular silicone tube placement combined with the word "Z" flap repair was used. We compared the two methods and studied the possible complications like eyelid varus and valgus, lacrimal point valgus, eyelid scar, anastomotic dehiscence again. RESULTS: Out of the 22 cases in which the patients chose the single spinal anesthesia tube implantation on skin suture, 21 cases succeeded and patients received lacrimal duct patency results after extubation; and 1 case anastomosis failed. Complications: 20 cases had different degree of complications and the impact on their appearances were significant. Out of the 23 cases in which the patients chose double passage annular silicone tube joint prosthesis implantation Z flap, 23 received extubation results lacrimal patency or almost patency, the anastomosis of patients was successful. Complications: in two cases, patients had mild eyelid entropion and pomatum varus. Both eyelid deformity and severe wound tear did not occur in all cases again. Scar was not obvious. The success rate of anastomosis between the two groups was not significantly different(P=0.4889. To compare the rate of complications, there were significant differences(χ2=30.42, PCONCLUSION: The application of dual ring implantation silicon tube combined with the word "Z" flap repair in the treatment of lacrimal canaliculi laceration of eyelid laceration ensured the success rate of

  10. Selective modification of halloysite lumen with octadecylphosphonic acid: new inorganic tubular micelle.

    Science.gov (United States)

    Yah, Weng On; Takahara, Atsushi; Lvov, Yuri M

    2012-01-25

    Selective fatty acid hydrophobization of the inner surface of tubule halloysite clay is demonstrated. Aqueous phosphonic acid was found to bind to alumina sites at the tube lumen and did not bind the tube's outer siloxane surface. The bonding was characterized with solid-state nuclear magnetic resonance ((29)Si, (13)C, (31)P NMR), Fourier transform infrared (FTIR), and X-ray photoelectron spectroscopy. NMR and FTIR spectroscopy of selectively modified tubes proved binding of octadecylphosphonic acid within the halloysite lumen through bidentate and tridentate P-O-Al linkage. Selective modification of the halloysite clay lumen creates an inorganic micelle-like architecture with a hydrophobic aliphatic chain core and a hydrophilic silicate shell. An enhanced capacity for adsorption of the modified halloysite toward hydrophobic derivatives of ferrocene was shown. This demonstrates that the different inner and outer surface chemistry of clay nanotubes can be used for selective modification, enabling different applications from water purification to drug immobilization and controlled release. © 2011 American Chemical Society

  11. Intrathoracic esophageal replacement in the dog with the use of an artificial esophagus composed of a collagen sponge with a double-layered silicone tube.

    Science.gov (United States)

    Yamamoto, Y; Nakamura, T; Shimizu, Y; Matsumoto, K; Takimoto, Y; Kiyotani, T; Sekine, T; Ueda, H; Liu, Y; Tamura, N

    1999-08-01

    Intrathoracic esophageal replacement with an artificial esophagus is considered difficult. We attempted to replace the intrathoracic esophagus with an artificial esophagus composed of a collagen sponge with a double-layered silicone tube and examined the state of host tissue regeneration. A 5-cm long gap was created in the intrathoracic esophagus in 9 dogs and repaired by interposition of our prosthesis. The dogs were fed only by intravenous hyperalimentation for 28 days. The silicone tube was removed at 29 days after the operation, and oral feeding was reintroduced. One dog was put to death at each of the following times: 1, 2, 3, 3, 6, 12, and 24 months after the operation. One dog is still surviving without problems after more than 26 months. One dog died of malnutrition at 10 months. In all dogs, the host regenerated tissue had replaced the resulting gap at the time of silicone tube removal. The mucosa had fully regenerated within 3 months and the glands within 12 months. The process of stenosis and shrinkage was complete within 3 months and did not advance thereafter. The lamina muscularis mucosae were observed as islets of smooth muscle within 12 months. Although the skeletal muscle regenerated close to the anastomoses, it did not extend to the middle of the regenerated esophagus even after 24 months. Use of a collagen sponge with a double-layered silicone tube was shown to be feasible even in the thorax and to allow the regenerated host tissue, consisting of the mucosa, glands, and lamina muscularis mucosae, to replace the esophageal gap.

  12. Studying the effect of the shape parameters on the performance of the darrieus wind turbine using the multiple double disk stream tube theory

    International Nuclear Information System (INIS)

    Elmabrok, Ali Mohamed; Al-makhlufi, Ahmed A.

    2006-01-01

    The performance of the Darrieus vertical axis turbine is comparable with that of the more common horizontal axis machines. It has a number of aerodynamic and structural advantages over HAWTS. However the darrieus turbines are not self-starting at low wind speeds which is a considerable disadvantage for a simple small scale installation. Generally, papers concerning vertical axis turbine do not study the behavior of the rotor at low tip speed ratios. Therefore they do not deal with the self starting problems. A number of analytical methods were investigated to see whether they could predict the starting performance of vertical axis turbines. The chosen methods and 'actuator disc theory' for multiple stream tubes. In this paper the multiple stream tube model is applied using two discs in tandem. The computational analysis of all models simulates the blade aerodynamics throughout the full range of incidence from 180 degree centigrade. The effects of varying various geometric parameters of the windmill upon the performance of the rotor are investigated to find a design with improved self starting characteristics. The best agreement between theory and experiment was obtained using the multiple stream tube (double disc) models.(Author)

  13. Maximizing Lumen Gain With Directional Atherectomy.

    Science.gov (United States)

    Stanley, Gregory A; Winscott, John G

    2016-08-01

    To describe the use of a low-pressure balloon inflation (LPBI) technique to delineate intraluminal plaque and guide directional atherectomy in order to maximize lumen gain and achieve procedure success. The technique is illustrated in a 77-year-old man with claudication who underwent superficial femoral artery revascularization using a HawkOne directional atherectomy catheter. A standard angioplasty balloon was inflated to 1 to 2 atm during live fluoroscopy to create a 3-dimensional "lumenogram" of the target lesion. Directional atherectomy was performed only where plaque impinged on the balloon at a specific fluoroscopic orientation. The results of the LPBI technique were corroborated with multimodality diagnostic imaging, including digital subtraction angiography, intravascular ultrasound, and intra-arterial pressure measurements. With the LPBI technique, directional atherectomy can routinely achieve <10% residual stenosis, as illustrated in this case, thereby broadly supporting a no-stent approach to lower extremity endovascular revascularization. © The Author(s) 2016.

  14. Multiple versus single lumen umbilical venous catheters for newborn infants.

    Science.gov (United States)

    Kabra, N S; Kumar, M; Shah, S S

    2005-07-20

    needed to treat (NNT) or number needed to harm (NNH) was calculated. Three studies qualified for inclusion in this review (Khilnani 1991; Loisel 1996; Soupre 1998). There was a decrease in the ML-UVCs group in the number of additional PIVs used in the first week of life [WMD -1.42, (95% CI -1.74, -1.10), pcatheter malfunction in the ML-UVCs group [typical RR 3.69 (95% CI 0.99, 13.81), p=0.05; RD 0.15 (95% CI 0.03, 0.27), p=0.01; NNH was 7, 95% CI 4, 33; n=99]. The following outcomes were not significantly different in the two groups: clinical sepsis, catheter related blood stream infection, catheter-associated thrombosis, complications related to catheter malposition in heart and great vessels, NEC and early neonatal mortality. The use of ML-UVCs in comparison to SL-UVCs in neonates is associated with decrease in the usage of PIVs in first week of life, but an increase in catheter malfunctions. As the quality of included randomized studies is poor and the estimates of clinically important complications are imprecise, no firm recommendations can be made regarding the choice of UVC. Adequately powered, properly randomized and properly blinded controlled trials are needed that address the effectiveness and safety of ML-UVCs (double and triple lumen) in comparison to SL-UVCs. These studies should also address the impact of type of catheter material.

  15. A clinical study of fallopian tube recanalization by comptesswely injecting contrast medunm into the uterus

    International Nuclear Information System (INIS)

    Xi Jiayuan; Jiang Yong; Zhu Ying; Gong Hiafeng; Lv Liang; Zhao Xinxiang; Fang Min; Wei Dingying; Hua Jian

    2006-01-01

    Objective: To search for a new, simple, rapid, safe and effective method with combination of hystero. Salingography and fallopian tube recanalization. Methods: After the double-lumen balloon catheter was inserted into the uterine cavity and then followed by saline or air injection into to the saccule. The internal os of cervix was thus blocked by the filled saccule. Iohexol was injected into uterine cavity and fallopian tubes to undertake hystero-salingography and selective radiography under the television observation. In case of obstruction the fallopian tube recanalization could be obtained by manual increasing the contrast injection pressure into the uterine cavity. Results: 2698 cases including 811 primary infertile women and 1887 cases of secondary infertilities were examed by this method. The number of obstructed fallopian tube was 3082 including 1561 right fallopian tubes and 1521 left ones. The rate of tube obstruction was 77.77% and that of tube recanalization was 88.96% including 2397 branches recanalized completely and 322 partially recanalizd. The venous reflux was found in 27 cases and light complications included slight vagina bleeding, mild transient spastic pain without mortality. Conclusion: This method of combining hystero-salinography and fallopian tube recanalization, is safe, effective, economic and practical for infertile women with quick procedure process; and worthy to be recommended. (authors)

  16. Vocal Fold Adjustment Caused by Phonation Into a Tube: A Double-Case Study Using Computed Tomography

    Czech Academy of Sciences Publication Activity Database

    Hampala, V.; Laukkanen, A. M.; Guzman, M.; Horáček, Jaromír; Švec, J. G.

    2015-01-01

    Roč. 29, č. 6 (2015), s. 733-742 ISSN 0892-1997 R&D Projects: GA ČR(CZ) GAP101/12/1306 Institutional support: RVO:61388998 Keywords : vocal folds * resonance tube * computed tomography Subject RIV: BI - Acoustics Impact factor: 1.113, year: 2015 http://ac.els-cdn.com/S0892199714002756/1-s2.0-S0892199714002756-main.pdf?_tid=58e41ed4-d4be-11e5-b79c-00000aab0f01&acdnat=1455635150_c180f8db4970456952fb802bf329392b

  17. Polarized protein transport and lumen formation during epithelial tissue morphogenesis.

    Science.gov (United States)

    Blasky, Alex J; Mangan, Anthony; Prekeris, Rytis

    2015-01-01

    One of the major challenges in biology is to explain how complex tissues and organs arise from the collective action of individual polarized cells. The best-studied model of this process is the cross talk between individual epithelial cells during their polarization to form the multicellular epithelial lumen during tissue morphogenesis. Multiple mechanisms of apical lumen formation have been proposed. Some epithelial lumens form from preexisting polarized epithelial structures. However, de novo lumen formation from nonpolarized cells has recently emerged as an important driver of epithelial tissue morphogenesis, especially during the formation of small epithelial tubule networks. In this review, we discuss the latest findings regarding the mechanisms and regulation of de novo lumen formation in vitro and in vivo.

  18. [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?].

    Science.gov (United States)

    Dengler, V; Wilde, P; Byhahn, C; Mack, M G; Schalk, R

    2011-02-01

    Laryngeal tubes (LT) are increasingly being used for emergency airway management. This article reports on two patients in whom out-of-hospital intubation with a single-lumen LT was associated with massive pulmonary aspiration in one patient and gastric overinflation in the other. In both cases peak inspiratory pressures exceeded the LT leak pressure of approximately 35 mbar. This resulted in gastric inflation and decreased pulmonary compliance and increased inspiratory pressure further, thereby creating a vicious circle. It is therefore recommended that laryngeal tube suction (LTS) should be used in all cases of emergency airway management and a gastric drain tube be inserted through the dedicated second lumen. Apart from gastric overinflation, incorrect LT/LTS placement must be detected and immediately corrected, e.g. in cases of difficult or impossible gastric tube placement, permanent drainage of air from the gastric tube, decreasing minute ventilation or an ascending capnography curve.

  19. Evolution of regular geometrical shapes in fiber lumens

    KAUST Repository

    Le, Ngoc Lieu; Kim, Dooli; Nunes, Suzana Pereira

    2017-01-01

    of the internal channels or lumens of polymeric hollow fibers, leading to polygonal geometries with increasing number of sides. The elasticity of the incipient channel skin and instabilities during fiber formation are affected by the internal coagulant fluid

  20. Mechanisms of lumen formation during sprouting angiogenesis in vivo

    OpenAIRE

    Gebala, V. M.

    2016-01-01

    During development, vascular networks expand following a process known as sprouting angiogenesis. New vascular branches arise from pre-existing vessels through the coordinated migration and proliferation of endothelial cells, and eventually connect to form new vascular loops. The functionality of these new vessel segments is dependent on the opening of a central lumen to allow perfusion. While mechanisms of lumen formation during the establishment of the primary vasculature by vasculogenesis ...

  1. Spermine oxidase promotes bile canalicular lumen formation through acrolein production.

    Science.gov (United States)

    Uemura, Takeshi; Takasaka, Tomokazu; Igarashi, Kazuei; Ikegaya, Hiroshi

    2017-11-01

    Spermine oxidase (SMOX) catalyzes oxidation of spermine to generate spermidine, hydrogen peroxide (H 2 O 2 ) and 3-aminopropanal, which is spontaneously converted to acrolein. SMOX is induced by a variety of stimuli including bacterial infection, polyamine analogues and acetaldehyde exposure. However, the physiological functions of SMOX are not yet fully understood. We investigated the physiological role of SMOX in liver cells using human hepatocellular carcinoma cell line HepG2. SMOX localized to the bile canalicular lumen, as determined by F-actin staining. Knockdown of SMOX reduced the formation of bile canalicular lumen. We also found that phospho-Akt (phosphorylated protein kinase B) was localized to canalicular lumen. Treatment with Akt inhibitor significantly reduced the formation of bile canalicular lumen. Acrolein scavenger also inhibited the formation of bile canalicular lumen. PTEN, phosphatase and tensin homolog and an inhibitor of Akt, was alkylated in a SMOX-dependent manner. Our results suggest that SMOX plays a central role in the formation of bile canalicular lumen in liver cells by activating Akt pathway through acrolein production.

  2. PdNP Decoration of Halloysite Lumen via Selective Grafting of Ionic Liquid onto the Aluminol Surfaces and Catalytic Application.

    Science.gov (United States)

    Dedzo, Gustave K; Ngnie, Gaëlle; Detellier, Christian

    2016-02-01

    The synthesis of selectively deposited palladium nanoparticles (PdNPs) inside tubular halloysite lumens is reported. This specific localization was directed by the selective modification of the aluminol surfaces of the clay mineral through stable Al-O-C bonds. An ionic liquid (1-(2-hydroxyethyl)-3-methylimidazolium) was grafted onto halloysite following the guest displacement method (generally used for kaolinite) using halloysite-DMSO preintercalate. The characterization of this clay nanohybrid material (XRD, NMR, TGA) showed characteristics reminiscent of similar materials synthesized from kaolinite. The grafting on halloysite lumens was also effective without using the DMSO preintercalate. The presence of these new functionalities in halloysite directs the synthesis of uniform PdNPs with size ranging between 3 and 6 nm located exclusively in the lumens. This results from the selective adsorption of PdNPs precursors in functionalized lumens through an anion exchange mechanism followed by in situ reduction. In contrast, the unmodified clay mineral displayed nanoparticles both inside and outside the tubes. These catalysts showed significant catalytic activity for the reduction of 4-nitrophenol (4-NP). The most efficient catalysts were recycled up to three times without reducing significantly the catalytic activities.

  3. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  4. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  5. Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography.

    Science.gov (United States)

    van Velsen, Evert F S; Niessen, Wiro J; de Weert, Thomas T; de Monyé, Cécile; van der Lugt, Aad; Meijering, Erik; Stokking, Rik

    2007-07-01

    Vessel image analysis is crucial when considering therapeutical options for (cardio-) vascular diseases. Our method, VAMPIRE (Vascular Analysis using Multiscale Paths Inferred from Ridges and Edges), involves two parts: a user defines a start- and endpoint upon which a lumen path is automatically defined, and which is used for initialization; the automatic segmentation of the vessel lumen on computed tomographic angiography (CTA) images. Both parts are based on the detection of vessel-like structures by analyzing intensity, edge, and ridge information. A multi-observer evaluation study was performed to compare VAMPIRE with a conventional method on the CTA data of 15 patients with carotid artery stenosis. In addition to the start- and endpoint, the two radiologists required on average 2.5 (SD: 1.9) additional points to define a lumen path when using the conventional method, and 0.1 (SD: 0.3) when using VAMPIRE. The segmentation results were quantitatively evaluated using Similarity Indices, which were slightly lower between VAMPIRE and the two radiologists (respectively 0.90 and 0.88) compared with the Similarity Index between the radiologists (0.92). The evaluation shows that the improved definition of a lumen path requires minimal user interaction, and that using this path as initialization leads to good automatic lumen segmentation results.

  6. Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography

    International Nuclear Information System (INIS)

    Velsen, Evert F.S. van; Niessen, Wiro J.; Meijering, Erik; Stokking, Rik; Weert, Thomas T. de; Monye, Cecile de; Lugt, Aad van der

    2007-01-01

    Vessel image analysis is crucial when considering therapeutical options for (cardio-) vascular diseases. Our method, VAMPIRE (Vascular Analysis using Multiscale Paths Inferred from Ridges and Edges), involves two parts: a user defines a start- and endpoint upon which a lumen path is automatically defined, and which is used for initialization; the automatic segmentation of the vessel lumen on computed tomographic angiography (CTA) images. Both parts are based on the detection of vessel-like structures by analyzing intensity, edge, and ridge information. A multi-observer evaluation study was performed to compare VAMPIRE with a conventional method on the CTA data of 15 patients with carotid artery stenosis. In addition to the start- and endpoint, the two radiologists required on average 2.5 (SD: 1.9) additional points to define a lumen path when using the conventional method, and 0.1 (SD: 0.3) when using VAMPIRE. The segmentation results were quantitatively evaluated using Similarity Indices, which were slightly lower between VAMPIRE and the two radiologists (respectively 0.90 and 0.88) compared with the Similarity Index between the radiologists (0.92). The evaluation shows that the improved definition of a lumen path requires minimal user interaction, and that using this path as initialization leads to good automatic lumen segmentation results. (orig.)

  7. Double-modification of lectin using two distinct chemistries for fluorescent ratiometric sensing and imaging saccharides in test tube or in cell.

    Science.gov (United States)

    Nakata, Eiji; Koshi, Yoichiro; Koga, Erina; Katayama, Yoshiki; Hamachi, Itaru

    2005-09-28

    The site-selective incorporation of two different fluorophores into a naturally occurring protein (lectin, a sugar-binding protein) has been successfully carried out using two distinct orthogonal chemical methods. By post-photoaffinity labeling modification, Con A, a glucose- and mannose-selective lectin, was modified with fluorescein in the proximity of the sugar binding site (Tyr100 site), and the controlled acylation reaction provided the site-selective attachment of coumarin at Lys114. In this doubly modified Con A, the fluorescein emission changed upon the binding to the corresponding sugars, such as the glucose or mannose derivatives, whereas the coumarin emission was constant. Thus, the doubly modified Con A fluorescently sensed the glucose- and mannose-rich saccharides in a ratiometric manner while retaining the natural binding selectivity and affinity, regardless of the double modification. On the benefit of the ratiometric fluorescent analysis using two distinct probes, the sugar trimming process of a glycoprotein can be precisely monitored by the engineered Con A. Furthermore, the doubly modified Con A can be used not only for the convenient fluorescent imaging of saccharides localized on a cell surface, such as the MCF-7, a breast cancer cell having rich high-mannose branch, but also for the ratiometric fluorescent sensing of the glucose concentration inside HepG2 cells. These results demonstrated that the semisynthetic lectin modified doubly by two distinct chemistries is superior to the singly modified one in function, and thus, it may be potentially useful in cell, as well as in test tube.

  8. Continuous insulin administration via complex central venous catheter infusion tubing is another risk factor for blood glucose imbalance. A retrospective study.

    Science.gov (United States)

    Maury, Eric; Vitry, Paola; Galbois, Arnauld; Ait-Oufella, Hafid; Baudel, Jean-Luc; Guidet, Bertrand; Offenstadt, Georges

    2012-06-14

    We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device. We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin]. Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71-48.8; p tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.

  9. Selective fabrication of iron oxide particles in halloysite lumen

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Pengwu; Du, Yuanyuan [School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, Jiangxi 330013 (China); Ma, Xiaofei, E-mail: maxiaofei@tju.edu.cn [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China)

    2015-02-01

    As the adsorbents or the supports of photocatalysts, halloysite nanotubes (HNT) were expected to have intact external surface for adsorption or catalyst immobilization, when Fe{sub 3}O{sub 4} particles was introduced to prepare magnetic HNTs for easy separation. The negatively charged urease was loaded inside positively charged HNT lumen, and urease catalyzed the hydrolysis of urea and resulted in the alkaline environment in HNT lumen. When Fe{sup 3+} and Fe{sup 2+} diffused in, Fe{sub 3}O{sub 4} particles were selectively synthesized in the lumen of HNT. The obtained Fe{sub 3}O{sub 4}@HNT is characterized by transmission electron microscopy and Fourier transform infrared spectroscopy, X-ray diffraction and hysteresis loops. The obtained magnetic Fe{sub 3}O{sub 4}@HNT can be magnetically collected with intact external surface, which can support photocatalysts or remove the pollutants. - Highlights: • Fe{sub 3}O{sub 4}@HNT was prepared. • Fe{sub 3}O{sub 4}@HNT was characterized. • Fe{sub 3}O{sub 4} particles were selectively synthesized in the lumen of HNT.

  10. Selective fabrication of iron oxide particles in halloysite lumen

    International Nuclear Information System (INIS)

    Zheng, Pengwu; Du, Yuanyuan; Ma, Xiaofei

    2015-01-01

    As the adsorbents or the supports of photocatalysts, halloysite nanotubes (HNT) were expected to have intact external surface for adsorption or catalyst immobilization, when Fe 3 O 4 particles was introduced to prepare magnetic HNTs for easy separation. The negatively charged urease was loaded inside positively charged HNT lumen, and urease catalyzed the hydrolysis of urea and resulted in the alkaline environment in HNT lumen. When Fe 3+ and Fe 2+ diffused in, Fe 3 O 4 particles were selectively synthesized in the lumen of HNT. The obtained Fe 3 O 4 @HNT is characterized by transmission electron microscopy and Fourier transform infrared spectroscopy, X-ray diffraction and hysteresis loops. The obtained magnetic Fe 3 O 4 @HNT can be magnetically collected with intact external surface, which can support photocatalysts or remove the pollutants. - Highlights: • Fe 3 O 4 @HNT was prepared. • Fe 3 O 4 @HNT was characterized. • Fe 3 O 4 particles were selectively synthesized in the lumen of HNT

  11. Hollow fiber membrane lumen modified by polyzwitterionic grafting

    KAUST Repository

    Le, Ngoc Lieu

    2016-08-24

    In this study, we demonstrate an effective way to modify the lumen of polyetherimide hollow fibers by grafting zwitterionic poly(sulfobetaine) to increase the membrane resistance to fouling. Surface-selective grafting of the protective hydrogel layers has been achieved in a facile two-step process. The first step is the adsorption of a macromolecular redox co-initiator on the lumen-side surface of the membrane, which in the second step, after flushing the lumen of the membrane with a solution comprising monomers and a complementary redox initiator, triggers the in situ cross-linking copolymerization at room temperature. The success of grafting reaction has been verified by the surface elemental analyses using X-ray photoelectron spectroscopy (XPS) and the surface charge evaluation using zeta potential measurements. The hydrophilicity of the grafted porous substrate is improved as indicated by the change of contact angle value from 44° to 30°, due to the hydration layer on the surface produced by the zwitterionic poly(sulfobetaine). Compared to the pristine polyetherimide (PEI) substrate, the poly(sulfobetaine) grafted substrates exhibit high fouling resistance against bovine serum albumin (BSA) adsorption, E. coli attachment and cell growth on the surface. Fouling minimization in the lumen is important for the use of hollow fibers in different processes. For instance, it is needed to preserve power density of pressure-retarded osmosis (PRO). In high-pressure PRO tests, a control membrane based on PEI with an external polyamide selective layer was seriously fouled by BSA, leading to a high water flux drop of 37%. In comparison, the analogous membrane, whose lumen was modified with poly(sulfobetaine), not only had a less water flux decline but also had better flux recovery, up to 87% after cleaning and hydraulic pressure impulsion. Clearly, grafting PRO hollow fiber membranes with zwitterionic polymeric hydrogels as a protective layer potentially sustains PRO

  12. Sudden endotracheal tube block in a patient of Achalasia Cardia

    Directory of Open Access Journals (Sweden)

    Ajit Gupta

    2012-01-01

    Full Text Available Endotracheal tube block due to various mechanical causes such as mucous, blood clot, denture, and ampoules have been reported. A patient of achalasia cardia with chronic passive aspiration pneumonitis developed mucoid mass in the respiratory passage which dislodged during the surgical procedure. The episode occurred almost an hour after induction of anesthesia and the dislodged mucoid mass blocked the lumen of endotracheal tube, leading to hypoxia and impending cardiac arrest. However, the patient was salvaged by replacing the tube.

  13. Photomultiplier tubes for Low Level Cerenkov Detectors

    International Nuclear Information System (INIS)

    Strindehag, O.

    1965-03-01

    Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a β-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10 -12 input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10 -12 to 10 -9 input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses

  14. Photomultiplier tubes for Low Level Cerenkov Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Strindehag, O

    1965-03-15

    Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a {beta}-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10{sup -12} input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10{sup -12} to 10{sup -9} input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses.

  15. The effectiveness of an endotracheal tube holder

    Directory of Open Access Journals (Sweden)

    Byung Gun Lim

    2016-01-01

    Full Text Available The security of the endotracheal tube (ETT is important in the anesthesia and intensive care settings. Recently, an ETT holder instead of an adhesive tape is frequently used to provide the fixation of the ETT. There are some studies that focused on the effectiveness of the ETT holder in preventing displacement of ETT compared to an adhesive tape (1, 2. I have experienced the use of an ETT holder (E-holder, KS medical, Bucheon, Korea in many different anesthesia settings and recognized its usefulness and convenience other than ETT security in the following specific settings.  Firstly, the ETT holder is definitely effective for patients undergoing procedures that frequently require the adjustment of ETT (or double lumen tube location including thoracic surgery. The location of double lumen tube needed for lung separation can be modified for effective ventilation during anesthetic induction or surgery, and after position changes. The tube can be easily relocated to the proper place for lung separation and effective ventilation by unlocking/relocking the button of the ETT holder under flexible bronchoscopic guidance (Fig. 1A, which can facilitate the operative procedure to be performed easily and quickly. Secondly, the ETT holder can be useful in procedures requiring the prone position (3. Especially, it is useful in all circumstances requiring the adjustment of ETT in the prone position. For instance, it is definitely useful for patients with Duchene muscular dystrophy undergoing scoliosis surgery under prone position. Adolescent patients with Duchene muscular dystrophy frequently have tracheobronchial malacia. If so, the airway pressure can be elevated due to the narrowing of the lesion of malacia when changed to the prone position (4. To overcome this problem, a reinforced ETT should be relocated so that it passes the narrowed tracheal lesion under flexible bronchoscopic guidance (Fig. 1B. However, the approach for this management is somewhat

  16. Scribble is required for normal epithelial cell–cell contacts and lumen morphogenesis in the mammalian lung

    Science.gov (United States)

    Yates, Laura L.; Schnatwinkel, Carsten; Hazelwood, Lee; Chessum, Lauren; Paudyal, Anju; Hilton, Helen; Romero, M. Rosario; Wilde, Jonathan; Bogani, Debora; Sanderson, Jeremy; Formstone, Caroline; Murdoch, Jennifer N.; Niswander, Lee A.; Greenfield, Andy; Dean, Charlotte H.

    2013-01-01

    During lung development, proper epithelial cell arrangements are critical for the formation of an arborized network of tubes. Each tube requires a lumen, the diameter of which must be tightly regulated to enable optimal lung function. Lung branching and lumen morphogenesis require close epithelial cell–cell contacts that are maintained as a result of adherens junctions, tight junctions and by intact apical–basal (A/B) polarity. However, the molecular mechanisms that maintain epithelial cohesion and lumen diameter in the mammalian lung are unknown. Here we show that Scribble, a protein implicated in planar cell polarity (PCP) signalling, is necessary for normal lung morphogenesis. Lungs of the Scrib mouse mutant Circletail (Crc) are abnormally shaped with fewer airways, and these airways often lack a visible, ‘open’ lumen. Mechanistically we show that Scrib genetically interacts with the core PCP gene Vangl2 in the developing lung and that the distribution of PCP pathway proteins and Rho mediated cytoskeletal modification is perturbed in ScribCrc/Crc lungs. However A/B polarity, which is disrupted in Drosophila Scrib mutants, is largely unaffected. Notably, we find that Scrib mediates functions not attributed to other PCP proteins in the lung. Specifically, Scrib localises to both adherens and tight junctions of lung epithelia and knockdown of Scrib in lung explants and organotypic cultures leads to reduced cohesion of lung epithelial cells. Live imaging of Scrib knockdown lungs shows that Scrib does not affect bud bifurcation, as previously shown for the PCP protein Celsr1, but is required to maintain epithelial cohesion. To understand the mechanism leading to reduced cell–cell association, we show that Scrib associates with β-catenin in embryonic lung and the sub-cellular distribution of adherens and tight junction proteins is perturbed in mutant lung epithelia. Our data reveal that Scrib is required for normal lung epithelial organisation and lumen

  17. Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years.

    Science.gov (United States)

    Shen, Yaqi; Hu, Xuemei; Zou, Xianlun; Zhu, Di; Li, Zhen; Hu, Daoyu

    2016-09-01

    Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. Overall, this review demonstrates that

  18. Public relations ve firmě LUMEN INTERNATIONAL a.s.

    OpenAIRE

    DICHTLOVÁ, Hana

    2012-01-01

    Goal of the thesis was to assess current significance and usage of public relations in LUMEN INTERNATIONAL a.s. company and to create plan of another development. The author analysed development and current situation of public relations in LUMEN holding. There are a few suggestions in this thesis how to improve public relations in whole LUMEN holding.

  19. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  20. ARCOCT: Automatic detection of lumen border in intravascular OCT images.

    Science.gov (United States)

    Cheimariotis, Grigorios-Aris; Chatzizisis, Yiannis S; Koutkias, Vassilis G; Toutouzas, Konstantinos; Giannopoulos, Andreas; Riga, Maria; Chouvarda, Ioanna; Antoniadis, Antonios P; Doulaverakis, Charalambos; Tsamboulatidis, Ioannis; Kompatsiaris, Ioannis; Giannoglou, George D; Maglaveras, Nicos

    2017-11-01

    Intravascular optical coherence tomography (OCT) is an invaluable tool for the detection of pathological features on the arterial wall and the investigation of post-stenting complications. Computational lumen border detection in OCT images is highly advantageous, since it may support rapid morphometric analysis. However, automatic detection is very challenging, since OCT images typically include various artifacts that impact image clarity, including features such as side branches and intraluminal blood presence. This paper presents ARCOCT, a segmentation method for fully-automatic detection of lumen border in OCT images. ARCOCT relies on multiple, consecutive processing steps, accounting for image preparation, contour extraction and refinement. In particular, for contour extraction ARCOCT employs the transformation of OCT images based on physical characteristics such as reflectivity and absorption of the tissue and, for contour refinement, local regression using weighted linear least squares and a 2nd degree polynomial model is employed to achieve artifact and small-branch correction as well as smoothness of the artery mesh. Our major focus was to achieve accurate contour delineation in the various types of OCT images, i.e., even in challenging cases with branches and artifacts. ARCOCT has been assessed in a dataset of 1812 images (308 from stented and 1504 from native segments) obtained from 20 patients. ARCOCT was compared against ground-truth manual segmentation performed by experts on the basis of various geometric features (e.g. area, perimeter, radius, diameter, centroid, etc.) and closed contour matching indicators (the Dice index, the Hausdorff distance and the undirected average distance), using standard statistical analysis methods. The proposed method was proven very efficient and close to the ground-truth, exhibiting non statistically-significant differences for most of the examined metrics. ARCOCT allows accurate and fully-automated lumen border

  1. Evolution of regular geometrical shapes in fiber lumens

    KAUST Repository

    Le, Ngoc Lieu

    2017-08-17

    The geometry of polymeric hollow fibers for hemodialysis or desalination is a key factor determining their performance. Deformations are frequently observed, but they are rather random. Here we were able to exactly control the shape evolution of the internal channels or lumens of polymeric hollow fibers, leading to polygonal geometries with increasing number of sides. The elasticity of the incipient channel skin and instabilities during fiber formation are affected by the internal coagulant fluid composition and flow rate; and highly influence the polygonal shape. We propose a holistic explanation by analyzing the thermodynamic, kinetic and rheological aspects involved in the skin formation and their synergy.

  2. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  3. The dual-gate lumen model of renal monoamine transport

    Directory of Open Access Journals (Sweden)

    Marty Hinz

    2010-07-01

    Full Text Available Marty Hinz1, Alvin Stein2, Thomas Uncini31Clinical Research, NeuroResearch Clinics, Inc. Cape Coral, Florida, USA; 2Stein Orthopedic Associates, Plantation, Florida, USA; 3DBS Labs, Duluth, Minnesota, USAAbstract: The three-phase response of urinary serotonin and dopamine in subjects ­simultaneously taking amino acid precursors of serotonin and dopamine has been defined.1,2 No model exists regarding the renal etiology of the three-phase response. This writing outlines a model explaining the origin of the three-phase response of urinary serotonin and dopamine. A “dual-gate lumen transporter model” for the basolateral monoamine transporters of the kidneys is proposed as being the etiology of the three-phase urinary serotonin and dopamine responses.Purpose: The purpose of this writing is to document the internal renal function model that has evolved in research during large-scale assay with phase interpretation of urinary serotonin and dopamine.Patients and methods: In excess of 75,000 urinary monoamine assays from more than 7,500 patients were analyzed. The serotonin and the dopamine phase were determined for specimens submitted in the competitive inhibition state. The phase determination findings were then correlated with peer-reviewed literature.Results: The correlation between the three-phase response of urinary serotonin and dopamine with internal renal processes of the bilateral monoamine transporter and the apical monoamine transporter of the proximal convoluted renal tubule cells is defined.Conclusion: The phase of urinary serotonin and dopamine is dependent on the status of the serotonin gate, dopamine gate, and lumen of the basolateral monoamine transporter while in the competitive inhibition state.Keywords: serotonin, dopamine, basolateral, apical, kidney, proximal

  4. Streak tube development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of a high-speed, high-resolution streak image tube is described. This is one task in the development of a streak camera system with digital electronic readout, whose primary application is for diagnostics in underground nuclear testing. This program is concerned with the development of a high-resolution streak image tube compatible with x-ray input and electronic digital output. The tube must be capable of time resolution down to 100 psec and spatial resolution to provide greater than 1000 resolution elements across the cathode (much greater than presently available). Another objective is to develop the capability to make design changes in tube configurations to meet different experimental requirements. A demountable prototype streak tube was constructed, mounted on an optical bench, and placed in a vacuum system. Initial measurements of the tube resolution with an undeflected image show a resolution of 32 line pairs per millimeter over a cathode diameter of one inch, which is consistent with the predictions of the computer simulations. With the initial set of unoptmized deflection plates, the resolution pattern appeared to remain unchanged for static deflections of +- 1/2-inch, a total streak length of one inch, also consistent with the computer simulations. A passively mode-locked frequency-doubled dye laser is being developed as an ultraviolet pulsed light source to measure dynamic tube resolution during streaking. A sweep circuit to provide the deflection voltage in the prototype tube has been designed and constructed and provides a relatively linear ramp voltage with ramp durations adjustable between 10 and 1000 nsec

  5. Advanced evacuated tube collectors

    Science.gov (United States)

    Schertz, W. W.; Hull, J. R.; Winston, R.; Ogallagher, J.

    1985-04-01

    The essence of the design concept for these new collectors is the integration of moderate levels of nonimaging concentration inside the evacuated tube itself. This permanently protects the reflection surfaces and allows the use of highly reflecting front surface mirrors with reflectances greater than 95%. Previous fabrication and long term testing of a proof-of-concept prototype has established the technical success of the concept. Present work is directed toward the development of a manufacturable unit that will be suitable for the widest possible range of applications. Design alternatives include scaling up the original prototype's tube diameter from 5 cm to 10 cm, using an internal shaped metal concentrating reflector, using a variety of profile shapes to minimize so-called gap losses and accommodate both single ended and double-ended flow geometries, and allowing the use of heat pipes for the absorber tube.

  6. Blood in the gastric lumen increases splanchnic blood flow and portal pressure in portal-hypertensive rats.

    Science.gov (United States)

    Chen, L; Groszmann, R J

    1996-10-01

    In portal-hypertensive humans, portal blood flow and pressure increase after a meal. These hemodynamic changes may increase variceal rupture risk. The aim of this study was to determine whether blood in the stomach lumen increases splanchnic flow and portal pressure (PP) in portal-hypertensive rats. superior mesenteric artery flow and PP were measured in conscious, unrestrained, fasted partial portal vein-ligated rats with chronically implanted Doppler flow probes or portal vein catheters before and after gavage with heparinized, warmed blood from donor rats, air, standard meal, or empty tube. Percentage of changes in flow and pressure from baseline were significantly greater after gavage with blood (an increase of 22.6% +/- 3.5% and an increase of 16.4% +/- 3.1%, respectively) than empty tube (an increase of 3.4% +/- 0.6% and a decrease of 5.4% +/- 3.5%, respectively) (P empty tube (P calories probably contributes to these hemodynamic changes. In patients with variceal hemorrhage, blood in the stomach may increase the risk of persistent variceal bleeding or rebleeding.

  7. Rationale and design of the East-West late lumen loss study: Comparison of late lumen loss between Eastern and Western drug-eluting stent study cohorts.

    Science.gov (United States)

    Harrison, Robert W; Radhakrishnan, Vaishnavi; Lam, Peter S; Allocco, Dominic J; Brar, Sandeep; Fahy, Martin; Fisher, Rebecca; Ikeno, Fumiaki; Généreux, Philippe; Kimura, Takeshi; Liu, Minglei; Lye, Weng Kit; Mintz, Gary S; Nagai, Hirofumi; Suzuki, Yuka; White, Roseann; Allen, John C; Krucoff, Mitchell W

    2016-12-01

    The contemporary evaluation of novel drug-eluting stents (DES) includes mechanistic observations that characterize postdeployment stent behavior. Quantification of late lumen loss due to neointimal hyperplasia 8-13 months after stent implantation, via quantitative coronary angiography (QCA), constitutes such an observation and is required by most regulatory authorities. Late lumen loss, as determined by QCA, has been validated as a surrogate for clinical endpoints such as target vessel revascularization. The mechanistic response to DES has not been directly compared across predominantly Asian or Western populations, whereas understanding their comparability across geographic populations could enhance global DES evaluation. The East-West late lumen loss study is designed to demonstrate whether the residual differences in late lumen loss, as assessed by QCA, is different between Eastern and Western DES recipients from studies with protocol angiography at 8-13 months of follow-up. Data from independent core laboratories that have characterized angiographic late lumen loss in DES clinical trials with protocol follow-up angiography will be compiled and dichotomized into Eastern and Western populations. A prospectively developed propensity score model incorporating clinical and anatomic variables affecting late lumen loss will be used to adjust comparisons of QCA measurements. Documentation of whether there are clinically meaningful differences in mechanistic response to DES implantation across genetically unique geographies could facilitate both the quality and efficiency of global device evaluation requiring invasive follow-up for novel stent designs. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Evaluation of Esophageal Motility Utilizing the Functional Lumen Imaging Probe.

    Science.gov (United States)

    Carlson, Dustin A; Kahrilas, Peter J; Lin, Zhiyue; Hirano, Ikuo; Gonsalves, Nirmala; Listernick, Zoe; Ritter, Katherine; Tye, Michael; Ponds, Fraukje A; Wong, Ian; Pandolfino, John E

    2016-12-01

    Esophagogastric junction (EGJ) distensibility and distension-mediated peristalsis can be assessed with the functional lumen imaging probe (FLIP) during a sedated upper endoscopy. We aimed to describe esophageal motility assessment using FLIP topography in patients presenting with dysphagia. In all, 145 patients (aged 18-85 years, 54% female) with dysphagia that completed upper endoscopy with a 16-cm FLIP assembly and high-resolution manometry (HRM) were included. HRM was analyzed according to the Chicago Classification of esophageal motility disorders; major esophageal motility disorders were considered "abnormal". FLIP studies were analyzed using a customized program to calculate the EGJ-distensibility index (DI) and generate FLIP topography plots to identify esophageal contractility patterns. FLIP topography was considered "abnormal" if EGJ-DI was esophageal motility and 29 normal motility. In all, 17 (50%) had abnormal FLIP topography including 13 (37%) with abnormal EGJ-DI. FLIP topography provides a well-tolerated method for esophageal motility assessment (especially to identify achalasia) at the time of upper endoscopy. FLIP topography findings that are discordant with HRM may indicate otherwise undetected abnormalities of esophageal function, thus FLIP provides an alternative and complementary method to HRM for evaluation of non-obstructive dysphagia.

  9. Synergy of cell-cell repulsion and vacuolation in a computational model of lumen formation.

    Science.gov (United States)

    Boas, Sonja E M; Merks, Roeland M H

    2014-03-06

    A key step in blood vessel development (angiogenesis) is lumen formation: the hollowing of vessels for blood perfusion. Two alternative lumen formation mechanisms are suggested to function in different types of blood vessels. The vacuolation mechanism is suggested for lumen formation in small vessels by coalescence of intracellular vacuoles, a view that was extended to extracellular lumen formation by exocytosis of vacuoles. The cell-cell repulsion mechanism is suggested to initiate extracellular lumen formation in large vessels by active repulsion of adjacent cells, and active cell shape changes extend the lumen. We used an agent-based computer model, based on the cellular Potts model, to compare and study both mechanisms separately and combined. An extensive sensitivity analysis shows that each of the mechanisms on its own can produce lumens in a narrow region of parameter space. However, combining both mechanisms makes lumen formation much more robust to the values of the parameters, suggesting that the mechanisms may work synergistically and operate in parallel, rather than in different vessel types.

  10. Synergy of cell–cell repulsion and vacuolation in a computational model of lumen formation

    Science.gov (United States)

    Boas, Sonja E. M.; Merks, Roeland M. H.

    2014-01-01

    A key step in blood vessel development (angiogenesis) is lumen formation: the hollowing of vessels for blood perfusion. Two alternative lumen formation mechanisms are suggested to function in different types of blood vessels. The vacuolation mechanism is suggested for lumen formation in small vessels by coalescence of intracellular vacuoles, a view that was extended to extracellular lumen formation by exocytosis of vacuoles. The cell–cell repulsion mechanism is suggested to initiate extracellular lumen formation in large vessels by active repulsion of adjacent cells, and active cell shape changes extend the lumen. We used an agent-based computer model, based on the cellular Potts model, to compare and study both mechanisms separately and combined. An extensive sensitivity analysis shows that each of the mechanisms on its own can produce lumens in a narrow region of parameter space. However, combining both mechanisms makes lumen formation much more robust to the values of the parameters, suggesting that the mechanisms may work synergistically and operate in parallel, rather than in different vessel types. PMID:24430123

  11. Nonvisualization of the gallbladder lumen on sonogram: a sign of acute viral hepatitis

    International Nuclear Information System (INIS)

    Lim, Jae Hoon; Ko, Young Tae

    1986-01-01

    Six cases of nonvisulization of the gallbladder lumen in patients with acute viral hepatitis are presented. Follow-up ultrasonographic examinations done during the convalescent period in 2 patients showed normal gallbladders and this was correlated with improvement in enzyme levels. It is suggested that acute viral hepatitis should be considered in the differential diagnosis of nonvisualization of the gallbladder lumen on sonogram.

  12. Nonvisualization of the gallbladder lumen on sonogram: a sign of acute viral hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jae Hoon; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1986-04-15

    Six cases of nonvisulization of the gallbladder lumen in patients with acute viral hepatitis are presented. Follow-up ultrasonographic examinations done during the convalescent period in 2 patients showed normal gallbladders and this was correlated with improvement in enzyme levels. It is suggested that acute viral hepatitis should be considered in the differential diagnosis of nonvisualization of the gallbladder lumen on sonogram.

  13. True-lumen and false-lumen diameter changes in the downstream aorta after frozen elephant trunk implantation.

    Science.gov (United States)

    Berger, Tim; Kreibich, Maximilian; Morlock, Julia; Kondov, Stoyan; Scheumann, Johannes; Kari, Fabian A; Rylski, Bartosz; Siepe, Matthias; Beyersdorf, Friedhelm; Czerny, Martin

    2018-02-19

    To evaluate early and mid-term clinical outcomes and to assess the potential of the frozen elephant trunk technique to induce remodelling of downstream aortic segments in acute and chronic thoracic aortic dissections. Over a 4-year period, 65 patients (48 men, aged 61 ± 12 years) underwent total aortic arch replacement using the frozen elephant trunk technique for acute (n = 31) and chronic (n = 34) thoracic aortic dissections at our institution. We assessed diameter changes at 3 levels: the L1 segment at the stent graft level; the L2 segment at the thoraco-abdominal transition level and the L3 segment at the coeliac trunk level. True-lumen (TL) and false-lumen (FL) diameter changes were assessed at each level. Fifty-six percent of patients had already undergone previous aortic or cardiac surgery. In-hospital mortality was 6%. Symptomatic spinal cord injury was not observed in this series. During a mean follow-up of 12 ± 12 months, late death was observed in 6% of patients. Aortic reinterventions in downstream aortic segments were performed in 28% at a mean of 394 ± 385 days. TL expansion and FL shrinkage were measured in all segments and were observed at each level. This effect was the most pronounced at the level of the stent graft in patients with chronic aortic dissection, TL diameter increased from 15 ± 17 mm before surgery to 28 ± 2 mm (P = 0.001) after 2 years, and the FL diameter decreased from 40 ± 11 mm before surgery to 32 ± 17 mm (P = 0.026). The frozen elephant trunk technique is associated with an excellent clinical outcome in a complex cohort of patients, and also effectively induces remodelling in downstream aortic segments in acute and chronic thoracic aortic dissections. The need for secondary interventions in downstream segments, which mainly depends on the extent of the underlying disease process, remains substantial. Further studies are required to assess the long-term outcome of

  14. Measurement of the delta34S value in methionine by double spike multi-collector thermal ionization mass spectrometry using Carius tube digestion.

    Science.gov (United States)

    Mann, Jacqueline L; Kelly, W Robert

    2010-09-15

    Methionine is an essential amino acid and is the primary source of sulfur for humans. Using the double spike ((33)S-(36)S) multi-collector thermal ionization mass spectrometry (MC-TIMS) technique, three sample bottles of a methionine material obtained from the Institute for Reference Materials and Measurements have been measured for delta(34)S and sulfur concentration. The mean delta(34)S value, relative to Vienna Canyon Diablo Troilite (VCDT), determined was 10.34 +/- 0.11 per thousand (n = 9) with the uncertainty reported as expanded uncertainties (U). These delta(34)S measurements include a correction for blank which has been previously ignored in studies of sulfur isotopic composition. The sulfur concentrations for the three bottles range from 56 to 88 microg/g. The isotope composition and concentration results demonstrate the high accuracy and precision of the DS-MC-TIMS technique for measuring sulfur in methionine.

  15. Preparation of lumen-loaded kenaf pulp with magnetite (Fe3O4)

    International Nuclear Information System (INIS)

    Zakaria, S.; Ong, B.H.; Ahmad, S.H.; Abdullah, M.; Yamauchi, T.

    2005-01-01

    Magnetic pulps were prepared from unbleached kenaf (hibiscus cannabinus L.) kraft pulps. Fe 3 O 4 or magnetite powder was used to load into the pulp's lumen and pit. Aluminum sulphate [Al 2 (SO 4 ) 3 ] (alum) and polyethylenimine (PEI), both mainly function as retention aid were used throughout the experiment and found to be beneficial in the preparation of this magnetic pulps. The ash content method was used to determine the amount of magnetite retained in the lumen and pit. The utilization of PEI up to 2% per pulp fibres was found to be the best result on lumen loading. The deposition of magnetite powder in lumen and pit is found decrease as the addition of PEI used is more than 2% per pulp fibres. Scanning electron microscope (SEM) clearly shows the distribution of magnetite deposited in the lumen. Tensile index and folding endurance of the loaded fibre decreased slightly as the percentage of loading pigment increased

  16. Automated quantification of bronchiectasis, airway wall thickening and lumen tapering in chest CT

    DEFF Research Database (Denmark)

    Perez-Rovira, Adria; Kuo, Wieying; Petersen, Jens

    thickness and accompanying artery radius), and inter-branch Lumen-Ratio (LR, ratio between a branch's lumen and its parent branch lumen radius, a tapering measurement) were computed. Because CF-related structural abnormalities only affect a portion of branches, the 75th percentile was used as summarising......Purpose: To automatically quantify airway structural properties visualised on CT in children with cystic fibrosis (CF) and controls, including: bronchiectasis, airway wall thickening, and lumen tapering. Methods and materials: The 3D surface of the airway lumen, outer wall, and bronchial arteries...... were obtained using a fully automatic, in-house developed, segmentation method. Subsequently, for each detected airway branch, the Airway-Artery Ratio (AAR, ratio between airway outer wall and accompanying artery radius, a bronchiectasis measurement), Wall-Artery Ratio (WAR, ratio between airway wall...

  17. A double-blind, placebo-controlled clinical trial of the effect of chlorpheniramine on the response of the nasal airway, middle ear and eustachian tube to provocative rhinovirus challenge.

    Science.gov (United States)

    Doyle, W J; McBride, T P; Skoner, D P; Maddern, B R; Gwaltney, J M; Uhrin, M

    1988-03-01

    This paper presents the results of a randomized, double-blind, placebo-controlled study of the efficacy of chlorpheniramine in relieving the symptoms and attenuating the pathophysiologic correlates of a rhinovirus "common cold." Forty healthy, adult, nonatopic subjects were randomly assigned to one of two treatment groups: active drug and placebo. On study Day 0, all subjects were challenged intranasally with rhinovirus type 39 (dose = 100 TCID50). Subjects were cloistered from Day 2 to Day 7, at which time they were treated with either chlorpheniramine or placebo. From 3 days before challenge to study Day 19, subjects had nasal patency assessed by rhinomanometry, eustachian tube function assessed by the 9-step test and sonotubometry, middle ear pressure assessed by tympanometry and nasal clearance assessed by the dyed-saccharin technique. Symptom diaries were maintained throughout the period of follow-up. During cloister, symptoms also were scored by interview, nasal secretions were quantified and nasal washings were performed for viral culture. Results showed that 19 (95%) subjects in the active-treatment group and 18 (90%) subjects in the placebo-treatment group shed virus. Symptomatic colds were observed in 63% of the active-treated and 83% of the placebo-treated subjects. Symptoms increased on Day 1 and peaked at Days 4 to 5. Detrimental changes in other measured functions consistent with those previously reported were observed. During the period of treatment, significant differences in the average symptom scores favoring the active-treatment group were observed for sneezing. Also, weight of expelled secretions was greater and mucociliary clearance rate less on some cloister days for the placebo-treated group. No significant differences between treatment groups in the objective measures of nasal congestion or the response of the middle ear and eustachian tube were documented.

  18. Steam generator tubing development for commercial fast breeder reactors

    International Nuclear Information System (INIS)

    Sessions, C.E.; Uber, C.F.

    1981-01-01

    The development work to design, manufacture, and evaluate pre-stressed double-wall 2/one quarter/ Cr-1 Mo steel tubing for commercial fast breeder reactor steam generator application is discussed. The Westinghouse plan for qualifying tubing vendors to produce this tubing is described. The results achieved to date show that a long length pre-stressed double-wall tube is both feasible and commercially available. The evaluation included structural analysis and experimental measurement of the pre-stress within tubes, as well as dimensional, metallurgical, and interface wear tests of tube samples produced. This work is summarized and found to meet the steam generator design requirements. 10 refs

  19. Claudin5a is required for proper inflation of Kupffer's vesicle lumen and organ laterality.

    Directory of Open Access Journals (Sweden)

    Jeong-Gyun Kim

    Full Text Available Left-right asymmetric organ development is critical to establish a proper body plan of vertebrates. In zebrafish, the Kupffer's vesicle (KV is a fluid-filled sac which controls asymmetric organ development, and a properly inflated KV lumen by means of fluid influx is a prerequisite for the asymmetric signal transmission. However, little is known about the components that support the paracellular tightness between the KV luminal epithelial cells to sustain hydrostatic pressure during KV lumen expansion. Here, we identified that the claudin5a (cldn5a is highly expressed at the apical surface of KV epithelial cells and tightly seals the KV lumen. Downregulation of cldn5a in zebrafish showed a failure in organ laterality that resulted from malformed KV. In addition, accelerated fluid influx into KV by combined treatment of forskolin and 3-isobutyl-1-methylxanthine failed to expand the partially-formed KV lumen in cldn5a morphants. However, malformed KV lumen and defective heart laterality in cldn5a morphants were significantly rescued by exogenous cldn5a mRNA, suggesting that the tightness between the luminal epithelial cells is important for KV lumen formation. Taken together, these findings suggest that cldn5a is required for KV lumen inflation and left-right asymmetric organ development.

  20. Claudin5a is required for proper inflation of Kupffer's vesicle lumen and organ laterality.

    Science.gov (United States)

    Kim, Jeong-Gyun; Bae, Sung-Jin; Lee, Hye Shin; Park, Ji-Hyeon; Kim, Kyu-Won

    2017-01-01

    Left-right asymmetric organ development is critical to establish a proper body plan of vertebrates. In zebrafish, the Kupffer's vesicle (KV) is a fluid-filled sac which controls asymmetric organ development, and a properly inflated KV lumen by means of fluid influx is a prerequisite for the asymmetric signal transmission. However, little is known about the components that support the paracellular tightness between the KV luminal epithelial cells to sustain hydrostatic pressure during KV lumen expansion. Here, we identified that the claudin5a (cldn5a) is highly expressed at the apical surface of KV epithelial cells and tightly seals the KV lumen. Downregulation of cldn5a in zebrafish showed a failure in organ laterality that resulted from malformed KV. In addition, accelerated fluid influx into KV by combined treatment of forskolin and 3-isobutyl-1-methylxanthine failed to expand the partially-formed KV lumen in cldn5a morphants. However, malformed KV lumen and defective heart laterality in cldn5a morphants were significantly rescued by exogenous cldn5a mRNA, suggesting that the tightness between the luminal epithelial cells is important for KV lumen formation. Taken together, these findings suggest that cldn5a is required for KV lumen inflation and left-right asymmetric organ development.

  1. Feeding Tubes

    Science.gov (United States)

    ... feeding therapies have been exhausted. Please review product brand and method of placement carefully with your physician ... Total Parenteral Nutrition. Resources: Oley Foundation Feeding Tube Awareness Foundation Children’s Medical Nutrition Alliance APFED’s Educational Webinar ...

  2. Difficulty with cuff deflation of reinforced tracheal tube caused by inflation line occlusion with silk thread ligation and fixation.

    Science.gov (United States)

    Gotoh, Sayoko; Sugiyama, Daisuke; Imai, Eriko; Kawamata, Mikito

    2015-03-05

    A reinforced tracheal tube, ligated with silk threads, was inserted into a tracheostomy orifice and fixed to the skin. The cuff inflation line of the reinforced tracheal tube became occluded. Reinforced 'armoured' tracheal tubes have a spiral of wire embedded into the wall of the tube to give strength and flexibility, and may be sharply bent without compromising the tube lumen. The tracheal cuff attached to the tube is inflated by injecting air through a narrow-diameter tube welded to the outside of the tracheal tube. When a reinforced tracheal tube is ligated and fixed with silk threads, it should be confirmed whether the tracheal tube cuff can be deflated and inflated after fixation. Moreover, because occlusion can be eliminated by removing all silk threads used to ligate a tracheal tube, they should be removed before extubation. 2015 BMJ Publishing Group Ltd.

  3. Steam generator tube extraction

    International Nuclear Information System (INIS)

    Delorme, H.

    1985-05-01

    To enable tube examination on steam generators in service, Framatome has now developed a process for removing sections of steam generator tubes. Tube sections can be removed without being damaged for treating the tube section expanded in the tube sheet

  4. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    Science.gov (United States)

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  5. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  6. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  7. On-line packed magnetic in-tube solid phase microextraction of acidic drugs such as naproxen and indomethacin by using Fe3O4@SiO2@layered double hydroxide nanoparticles with high anion exchange capacity.

    Science.gov (United States)

    Shamsayei, Maryam; Yamini, Yadollah; Asiabi, Hamid; Safari, Meysam

    2018-02-22

    The authors describe a 3-component nanoparticle system composed of a silica-coated magnetite (Fe 3 O 4 ) core and a layered double (Cu-Cr) hydroxide nanoplatelet shell. The sorbent has a high anion exchange capacity for extraction anionic species. A simple online system, referred to as "on-line packed magnetic-in-tube solid phase microextraction" was designed. The nanoparticles were placed in a stainless steel cartridge via dry packing. The cartridge was then applied to the preconcentration acidic drugs including naproxen and indomethacin from urine and plasma. Extraction and desorption times, pH values of the sample solution and flow rates of sample solution and eluent were optimized. Analytes were then quantified by HPLC with UV detection. Under optimal conditions, the limits of detection range from 70 to 800 ng L -1 , with linear responses from 0.1-500 μg L -1 (water samples), 0.6-500 μg L -1 (spiked urine), and 0.9-500 μg L -1 (spiked plasma). The inter- and intra-assay precisions (RSDs, for n = 5) are in the range of 2.2-5.4%, 2.8-4.9%, and 2.0-5.2% at concentration levels of 5, 25 and 50 μg L -1 , respectively. The method was applied to the analysis of the drugs in spiked human urine and plasma, and good results were achieved. Graphical abstract Fe 3 O 4 @SiO 2 @CuCr-LDH magnetic nanoparticles were synthesized and packed in to a stainless steel column. The column was applied to solid phase microextraction of acidic drugs from biological samples.

  8. Problem in tracheostomy patient care: recognizing the patient with a displaced tracheostomy tube.

    Science.gov (United States)

    Seay, S J; Gay, S L

    1997-01-01

    There are times when a tracheostomy tube slips out of the trachea. A displaced tracheostomy tube can occur in any patient but is frequently seen in the patient with a full neck. In the overweight patient or patient with a full neck, the tracheostomy tube must pass through a greater amount of soft tissue. Because of this, a smaller portion of the tube is actually within the lumen of the trachea. When the patient coughs excessively or moves the head, the tube can easily slip out of the trachea and into the interstitial tissues of the neck. If the patient has complete obstruction of the upper airway, a displaced tracheostomy tube will result in immediate respiratory distress and can lead to respiratory arrest. If the patient has an intact or at least a partially open upper airway, the displaced tube may not cause an immediate problem. Therefore, displacement of the tracheostomy tube may not be obvious in the patient with a partial airway.

  9. Coaxial Tubing Systems Increase Artificial Airway Resistance and Work of Breathing.

    Science.gov (United States)

    Wenzel, Christin; Schumann, Stefan; Spaeth, Johannes

    2017-09-01

    Tubing systems are an essential component of the ventilation circuit, connecting the ventilator to the patient's airways. Coaxial tubing systems incorporate the inspiratory tube within the lumen of the expiratory one. We hypothesized that by design, these tubing systems increase resistance to air flow compared with conventional ones. We investigated the flow-dependent pressure gradient across coaxial, conventional disposable, and conventional reusable tubing systems from 3 different manufacturers. Additionally, the additional work of breathing and perception of resistance during breathing through the different devices were determined in 18 healthy volunteers. The pressure gradient across coaxial tubing systems was up to 6 times higher compared with conventional ones (1.90 ± 0.03 cm H 2 O vs 0.34 ± 0.01 cm H 2 O, P tubing systems, accordingly. Our findings suggest that the use of coaxial tubing systems should be carefully considered with respect to their increased resistance. Copyright © 2017 by Daedalus Enterprises.

  10. The Mashups of YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2013-01-01

    This article focuses on YouTube mashups and how we can understand them as a specific subgenre on YouTube. The Mashups are analysed as audiovisual recontextualizations that are given new meaning, e.g., via collaborative social communities or for individual promotional purposes. This is elaborated......, but rather in its social and communicative abilities within the YouTube community. This leads to the article’s overall argument that the main characteristic of the YouTube Mashup can be explained in terms of connectivity. It is argued that Mashups reveal a double articulation of connectivity; one...... that involves the social mechanisms of the Mashups, and another mode, which concerns the explicit embedding of structural connectivity that accentuates the medium-specific infrastructure of YouTube. This double articulation of connectivity is furthermore elaborated on by including Grusin and Bolter’s concept...

  11. Microscopic alterations in silicone tubes surface after application of ophthalmological lubricants

    Directory of Open Access Journals (Sweden)

    Jacqueline Sousa

    2015-02-01

    Full Text Available Objective: To identify microscopic morphological alterations in the surface of silicone tubes used for intubation of the lachrymal system after exposure to ophthalmological lubricants. Methods: Experimental, descriptive and longitudinal study consisted of the application of ophthalmological lubricants in silicone tubes. The tubes were divided in: Group 1 (Cylocort®, 2 (Epitezan®, 3 (Labcaína®, 4 (Liposic®, 5 (Maxinom® and 6 (Vista Gel®. One tube was not exposed to any lubricant, used as control. The tubes were observed and photographed after 2 hours, 30 days, 45 days before and after cleaning the surface and lumen. The following aspects were observed: surface (regularity, transparency, quantity, size and shape of the substances and lumen (obstruction. Results: Control: irregular surface with pores after 2 hours: Group 1 – irregular surface with presence of film; Groups 2, 3 and 5 – abundant and irregular quantity of ointment at the surface; Group 4 – discrete modification at the surface; Group 6 – growth of pigmented (brownish structures with filaments in the lumen, with discrete film in the surface. 30 Days: Groups 1, 4 and 5 – increase of the irregular superficial film; Group 2 – crust with notorious horizontal lines; Group 3 – diminution of the superficial film; Group 4 – crust less evident. Group 6 – increase of the structure seen with 2 hours of exposition, arboriform aspect. Forty-five days pre cleaning: Group 4 – diminution of the surface crust; Group 6 – expansion of the arboriform structure; unaltered findings in other groups. 45 days after cleaning: Groups 1 and 5 – light diminution of the surface crust; Groups 2, 3 and 4 – kept the modifications; Group 6 – the structure inside the lumen was not identified, clear surface, without evidence of film. Conclusions: Microscopic morphological alterations in the surface and lumen of silicone tubes can occur when those remain in contact with determined

  12. Drosophila convoluted/dALS is an essential gene required for tracheal tube morphogenesis and apical matrix organization.

    Science.gov (United States)

    Swanson, Lianna E; Yu, Marcus; Nelson, Kevin S; Laprise, Patrick; Tepass, Ulrich; Beitel, Greg J

    2009-04-01

    Insulin-like growth factors (IGFs) control cell and organism growth through evolutionarily conserved signaling pathways. The mammalian acid-labile subunit (ALS) is a secreted protein that complexes with IGFs to modulate their activity. Recent work has shown that a Drosophila homolog of ALS, dALS, can also complex with and modulate the activity of a Drosophila IGF. Here we report the first mutations in the gene encoding dALS. Unexpectedly, we find that these mutations are allelic to a previously described mutation in convoluted (conv), a gene required for epithelial morphogenesis. In conv mutants, the tubes of the Drosophila tracheal system become abnormally elongated without altering tracheal cell number. conv null mutations cause larval lethality, but do not disrupt several processes required for tracheal tube size control, including septate junction formation, deposition of a lumenal/apical extracellular matrix, and lumenal secretion of Vermiform and Serpentine, two putative matrix-modifying proteins. Clearance of lumenal matrix and subcellular localization of clathrin also appear normal in conv mutants. However, we show that Conv/dALS is required for the dynamic organization of the transient lumenal matrix and normal structure of the cuticle that lines the tracheal lumen. These and other data suggest that the Conv/dALS-dependent tube size control mechanism is distinct from other known processes involved in tracheal tube size regulation. Moreover, we present evidence indicating that Conv/dALS has a novel, IGF-signaling independent function in tracheal morphogenesis.

  13. A recoil resilient lumen support, design, fabrication and mechanical evaluation

    Science.gov (United States)

    Mehdizadeh, Arash; Ali, Mohamed Sultan Mohamed; Takahata, Kenichi; Al-Sarawi, Said; Abbott, Derek

    2013-06-01

    Stents are artificial implants that provide scaffolding to a cavity inside the body. This paper presents a new luminal device for reducing the mechanical failure of stents due to recoil, which is one of the most important issues in stenting. This device, which we call a recoil-resilient ring (RRR), is utilized standalone or potentially integrated with existing stents to address the problem of recoil. The proposed structure aims to minimize the need for high-pressure overexpansion that can induce intra-luminal trauma and excess growth of vascular tissue causing later restenosis. The RRR is an overlapped open ring with asymmetrical sawtooth structures that are intermeshed. These teeth can slide on top of each other, while the ring is radially expanded, but interlock step-by-step so as to keep the final expanded state against compressional forces that normally cause recoil. The RRRs thus deliver balloon expandability and, when integrated with a stent, bring both radial rigidity and longitudinal flexibility to the stent. The design of the RRR is investigated through finite element analysis (FEA), and then the devices are fabricated using micro-electro-discharge machining of 200-µm-thick Nitinol sheet. The standalone RRR is balloon expandable in vitro by 5-7 Atm in pressure, which is well within the recommended in vivo pressure ranges for stenting procedures. FEA compression tests indicate 13× less reduction of the cross-sectional area of the RRR compared with a typical stainless steel stent. These results also show perfect elastic recovery of the RRR after removal of the pressure compared to the remaining plastic deformations of the stainless steel stent. On the other hand, experimental loading tests show that the fabricated RRRs have 2.8× radial stiffness compared to a two-column section of a commercial stent while exhibiting comparable elastic recovery. Furthermore, testing of in vitro expansion in a mock artery tube shows around 2.9% recoil, approximately 5-11

  14. A recoil resilient lumen support, design, fabrication and mechanical evaluation

    International Nuclear Information System (INIS)

    Mehdizadeh, Arash; Al-Sarawi, Said; Abbott, Derek; Ali, Mohamed Sultan Mohamed; Takahata, Kenichi

    2013-01-01

    Stents are artificial implants that provide scaffolding to a cavity inside the body. This paper presents a new luminal device for reducing the mechanical failure of stents due to recoil, which is one of the most important issues in stenting. This device, which we call a recoil-resilient ring (RRR), is utilized standalone or potentially integrated with existing stents to address the problem of recoil. The proposed structure aims to minimize the need for high-pressure overexpansion that can induce intra-luminal trauma and excess growth of vascular tissue causing later restenosis. The RRR is an overlapped open ring with asymmetrical sawtooth structures that are intermeshed. These teeth can slide on top of each other, while the ring is radially expanded, but interlock step-by-step so as to keep the final expanded state against compressional forces that normally cause recoil. The RRRs thus deliver balloon expandability and, when integrated with a stent, bring both radial rigidity and longitudinal flexibility to the stent. The design of the RRR is investigated through finite element analysis (FEA), and then the devices are fabricated using micro-electro-discharge machining of 200-µm-thick Nitinol sheet. The standalone RRR is balloon expandable in vitro by 5–7 Atm in pressure, which is well within the recommended in vivo pressure ranges for stenting procedures. FEA compression tests indicate 13× less reduction of the cross-sectional area of the RRR compared with a typical stainless steel stent. These results also show perfect elastic recovery of the RRR after removal of the pressure compared to the remaining plastic deformations of the stainless steel stent. On the other hand, experimental loading tests show that the fabricated RRRs have 2.8× radial stiffness compared to a two-column section of a commercial stent while exhibiting comparable elastic recovery. Furthermore, testing of in vitro expansion in a mock artery tube shows around 2.9% recoil, approximately 5

  15. Electron tube

    Science.gov (United States)

    Suyama, Motohiro [Hamamatsu, JP; Fukasawa, Atsuhito [Hamamatsu, JP; Arisaka, Katsushi [Los Angeles, CA; Wang, Hanguo [North Hills, CA

    2011-12-20

    An electron tube of the present invention includes: a vacuum vessel including a face plate portion made of synthetic silica and having a surface on which a photoelectric surface is provided, a stem portion arranged facing the photoelectric surface and made of synthetic silica, and a side tube portion having one end connected to the face plate portion and the other end connected to the stem portion and made of synthetic silica; a projection portion arranged in the vacuum vessel, extending from the stem portion toward the photoelectric surface, and made of synthetic silica; and an electron detector arranged on the projection portion, for detecting electrons from the photoelectric surface, and made of silicon.

  16. Endoscopic Retrograde Cholangiopancreatography Using a Dual-Lumen Endogastroscope for Patients with Billroth II Gastrectomy

    Directory of Open Access Journals (Sweden)

    Wei Yao

    2013-01-01

    Full Text Available Objective. To evaluate the safety and efficacy of a dual-lumen forward-viewing endoscope for ERCP in patients with prior Billroth II gastrectomy. Methods. The records of 46 patients treated with ERCP by a dual-lumen forward-viewing endoscope after Billroth II gastrectomy from 2007 to 2012 were reviewed. Results. The success rate of selective cannulation was 82.6% (38/46. Of the 38 cases with successful selective cannulation, endoscopic sphincterotomy was achieved in 23 cases by placing the needle knife through the 2nd lumen, while endoscopic papillary balloon dilatation was conducted in the other 15 cases. Of the 8 failed cases of selective cannulation, 6 had failed afferent loop intubation, and 3 of these 6 patients had Braun’s anastomosis. The safety and efficacy of catheter-assisted endoscopic sphincterotomy were increased by placing the needle knife through the 2nd lumen without altering the conventional endoscopic sphincterotomy procedure. Conclusions. A dual-lumen forward-viewing endoscope can be safely and effectively used to perform ERCP in patients with a Billroth II gastrectomy, except for patients with additional Braun’s anastomosis.

  17. Age-Related Changes in Pharyngeal Lumen Size: A Retrospective MRI Analysis.

    Science.gov (United States)

    Molfenter, Sonja M; Amin, M R; Branski, R C; Brumm, J D; Hagiwara, M; Roof, S A; Lazarus, C L

    2015-06-01

    Age-related loss of muscle bulk and strength (sarcopenia) is often cited as a potential mechanism underlying age-related changes in swallowing. Our goal was to explore this phenomenon in the pharynx, specifically, by measuring pharyngeal wall thickness and pharyngeal lumen area in a sample of young versus older women. MRI scans of the neck were retrospectively reviewed from 60 women equally stratified into three age groups (20s, 60s, 70+). Four de-identified slices were extracted per scan for randomized, blinded analysis: one mid-sagittal and three axial slices were selected at the anterior inferior border of C2 and C3, and at the pit of the vallecula. Pixel-based measures of pharyngeal wall thickness and pharyngeal lumen area were completed using ImageJ and then converted to metric units. Measures of pharyngeal wall thickness and pharyngeal lumen area were compared between age groups with one-way ANOVAs using Sidak adjustments for post-hoc pairwise comparisons. A significant main effect for age was observed across all variables whereby pharyngeal wall thickness decreased and pharyngeal lumen area increased with advancing age. Pairwise comparisons revealed significant differences between 20s versus 70+ for all variables and 20s versus 60s for all variables except those measured at C2. Effect sizes ranged from 0.54 to 1.34. Consistent with existing sacropenia literature, the pharyngeal muscles appear to atrophy with age and consequently, the size of the pharyngeal lumen increases.

  18. Long-term lumen depreciation behavior and failure modes of multi-die array LEDs

    Science.gov (United States)

    Jayawardena, Asiri; Marcus, Daniel; Prugue, Ximena; Narendran, Nadarajah

    2013-09-01

    One of the main advantages of multi-die array light-emitting diodes (LEDs) is their high flux density. However, a challenge for using such a product in lighting fixture applications is the heat density and the need for thermal management to keep the junction temperatures of all the dies low for long-term reliable performance. Ten multi-die LED array samples for each product from four different manufacturers were subjected to lumen maintenance testing (as described in IES-LM-80-08), and their resulting lumen depreciation and failure modes were studied. The products were tested at the maximum case (or pin) temperature reported by the respective manufacturer by appropriately powering the LEDs. In addition, three samples for each product from two different manufacturers were subjected to rapid thermal cycling, and the resulting lumen depreciation and failure modes were studied. The results showed that the exponential lumen decay model using long-term lumen maintenance data as recommended in IES TM-21 does not fit for all package types. The failure of a string of dies and single die failure in a string were observed in some of the packages.

  19. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  20. Obstruction of endotracheal tube with relevant respiratory acidosis during pediatric cardiac surgery

    NARCIS (Netherlands)

    Morei, N.M.; Mungroop, H. E.; Michielon, Guido; Scheeren, Thomas

    2014-01-01

    We describe a case of pediatric cardiac surgery in a 21- days old baby, in whom a nasal endotracheal tube (ETT) was inserted. At the end of surgery both ventilatory pressures and end-tidal CO2 increased suggesting airway obstruction. Suctioning of the ETT lumen did not relieve the problem, only ETT

  1. Evaluation of an improved technique for automated center lumen line definition in cardiovascular image data

    International Nuclear Information System (INIS)

    Gratama van Andel, Hugo A.F.; Meijering, Erik; Vrooman, Henri A.; Stokking, Rik; Lugt, Aad van der; Monye, Cecile de

    2006-01-01

    The aim of the study was to evaluate a new method for automated definition of a center lumen line in vessels in cardiovascular image data. This method, called VAMPIRE, is based on improved detection of vessel-like structures. A multiobserver evaluation study was conducted involving 40 tracings in clinical CTA data of carotid arteries to compare VAMPIRE with an established technique. This comparison showed that VAMPIRE yields considerably more successful tracings and improved handling of stenosis, calcifications, multiple vessels, and nearby bone structures. We conclude that VAMPIRE is highly suitable for automated definition of center lumen lines in vessels in cardiovascular image data. (orig.)

  2. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  3. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  4. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  5. Fate of the dissecting lumen by CT study following surgical repair

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Nobuyuki; Ando, Taizo; Kawazoe, Kohei; Tomino, Tetsuo; Fujita, Takeshi; Naito, Hiroaki; Yamaguchi, Toshio

    1983-03-01

    A postoperative follow-up study on the fate of dissecting lumen by means of computer tomography has been evaluated. The materials were 21 patients who underwent surgery for dissection of the aorta, including 8 patients in type 1 of DeBakey classification, 3 in type 11, 8 in type 111 and 2 patients of localized dissection in descending and abdominal aorta. The susceptibility for thrombus formation in dissecting lumen appeared to be related to the background etiology of dissection where poor tendency for thrombus formation was observed in a group of patients with Marfan syndrome and its' incomplete form. On the other hand in the group of patients who had a history of hypertension and atherosclerosis probable, a strong tendency of thrombus formation and eventual occlusion of lumen was obtained. On the basis of above findings, it will be said that the surgical intervention for type 1 of DeBakey classification in Marfan patient is merely creating type 111 dissection, closed observation in the future change of dissecting lumen is of utmost importance especially in those groups of patients.

  6. Fate of the dissecting lumen by CT study following surgical repair

    International Nuclear Information System (INIS)

    Nakajima, Nobuyuki; Ando, Taizo; Kawazoe, Kohei; Tomino, Tetsuo; Fujita, Takeshi; Naito, Hiroaki; Yamaguchi, Toshio.

    1983-01-01

    A postoperative follow-up study on the fate of dissecting lumen by mean of computer tomography has been evaluated. The materials were 21 patients who underwent surgery for dissection of the aorta, including 8 patients in type 1 of DeBakey classification, 3 in type 11, 8 in type 111 and 2 patients of localized dissection in descending and abdominal aorta. The susceptibility for thrombus formation in dissecting lumen appeared to be relating to the background etiology of dissection where poor tendency for thrombus formation was observed in group of patients with Marfan syndrome and its' incomplete form. On the other hand in those group of patients who had a history of hypertension and atherosclerosis probable, a strong tendency of thrombus formation and eventual occlusion of lumen was obtained. On the basis of above findings, it will be said that the surgical intervention for type 1 of DeBakey classification in Marfan patient is merely creating type 111 dissection, closed observation in the future change of dissecting lumen is utmost important especially in those group of patients. (author)

  7. Lumen Formation Is an Intrinsic Property of Isolated Human Pluripotent Stem Cells

    Directory of Open Access Journals (Sweden)

    Kenichiro Taniguchi

    2015-12-01

    Full Text Available We demonstrate that dissociated human pluripotent stem cells (PSCs are intrinsically programmed to form lumens. PSCs form two-cell cysts with a shared apical domain within 20 hr of plating; these cysts collapse to form monolayers after 5 days. Expression of pluripotency markers is maintained throughout this time. In two-cell cysts, an apical domain, marked by EZRIN and atypical PKCζ, is surrounded by apically targeted organelles (early endosomes and Golgi. Molecularly, actin polymerization, regulated by ARP2/3 and mammalian diaphanous-related formin 1 (MDIA, promotes lumen formation, whereas actin contraction, mediated by MYOSIN-II, inhibits this process. Finally, we show that lumenal shape can be manipulated in bioengineered micro-wells. Since lumen formation is an indispensable step in early mammalian development, this system can provide a powerful model for investigation of this process in a controlled environment. Overall, our data establish that lumenogenesis is a fundamental cell biological property of human PSCs.

  8. Analysis of proteome dynamics inside the silk gland lumen of Bombyx mori

    Science.gov (United States)

    Dong, Zhaoming; Zhao, Ping; Zhang, Yan; Song, Qianru; Zhang, Xiaolu; Guo, Pengchao; Wang, Dandan; Xia, Qingyou

    2016-01-01

    The silk gland is the only organ where silk proteins are synthesized and secreted in the silkworm, Bombyx mori. Silk proteins are stored in the lumen of the silk gland for around eight days during the fifth instar. Determining their dynamic changes is helpful for clarifying the secretion mechanism of silk proteins. Here, we identified the proteome in the silk gland lumen using liquid chromatography–tandem mass spectrometry, and demonstrated its changes during two key stages. From day 5 of the fifth instar to day 1 of wandering, the abundances of fibroins, sericins, seroins, and proteins of unknown functions increased significantly in different compartments of the silk gland lumen. As a result, these accumulated proteins constituted the major cocoon components. In contrast, the abundances of enzymes and extracellular matrix proteins decreased in the silk gland lumen, suggesting that they were not the structural constituents of silk. Twenty-five enzymes may be involved in the regulation of hormone metabolism for proper silk gland function. In addition, the metabolism of other non-proteinous components such as chitin and pigment were also discussed in this study. PMID:27102218

  9. An artificial neural network method for lumen and media-adventitia border detection in IVUS.

    Science.gov (United States)

    Su, Shengran; Hu, Zhenghui; Lin, Qiang; Hau, William Kongto; Gao, Zhifan; Zhang, Heye

    2017-04-01

    Intravascular ultrasound (IVUS) has been well recognized as one powerful imaging technique to evaluate the stenosis inside the coronary arteries. The detection of lumen border and media-adventitia (MA) border in IVUS images is the key procedure to determine the plaque burden inside the coronary arteries, but this detection could be burdensome to the doctor because of large volume of the IVUS images. In this paper, we use the artificial neural network (ANN) method as the feature learning algorithm for the detection of the lumen and MA borders in IVUS images. Two types of imaging information including spatial, neighboring features were used as the input data to the ANN method, and then the different vascular layers were distinguished accordingly through two sparse auto-encoders and one softmax classifier. Another ANN was used to optimize the result of the first network. In the end, the active contour model was applied to smooth the lumen and MA borders detected by the ANN method. The performance of our approach was compared with the manual drawing method performed by two IVUS experts on 461 IVUS images from four subjects. Results showed that our approach had a high correlation and good agreement with the manual drawing results. The detection error of the ANN method close to the error between two groups of manual drawing result. All these results indicated that our proposed approach could efficiently and accurately handle the detection of lumen and MA borders in the IVUS images. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Ezetimibe Promotes Brush Border Membrane-to-Lumen Cholesterol Efflux in the Small Intestine.

    Directory of Open Access Journals (Sweden)

    Takanari Nakano

    Full Text Available Ezetimibe inhibits Niemann-Pick C1-like 1 (NPC1L1, an apical membrane cholesterol transporter of enterocytes, thereby reduces intestinal cholesterol absorption. This treatment also increases extrahepatic reverse cholesterol transport via an undefined mechanism. To explore this, we employed a trans-intestinal cholesterol efflux (TICE assay, which directly detects circulation-to-intestinal lumen 3H-cholesterol transit in a cannulated jejunal segment, and found an increase of TICE by 45%. To examine whether such increase in efflux occurs at the intestinal brush border membrane(BBM-level, we performed luminal perfusion assays, similar to TICE but the jejunal wall was labelled with orally-given 3H-cholesterol, and determined elevated BBM-to-lumen cholesterol efflux by 3.5-fold with ezetimibe. Such increased efflux probably promotes circulation-to-lumen cholesterol transit eventually; thus increases TICE. Next, we wondered how inhibition of NPC1L1, an influx transporter, resulted in increased efflux. When we traced orally-given 3H-cholesterol in mice, we found that lumen-to-BBM 3H-cholesterol transit was rapid and less sensitive to ezetimibe treatment. Comparison of the efflux and fractional cholesterol absorption revealed an inverse correlation, indicating the efflux as an opposite-regulatory factor for cholesterol absorption efficiency and counteracting to the naturally-occurring rapid cholesterol influx to the BBM. These suggest that the ezetimibe-stimulated increased efflux is crucial in reducing cholesterol absorption. Ezetimibe-induced increase in cholesterol efflux was approximately 2.5-fold greater in mice having endogenous ATP-binding cassette G5/G8 heterodimer, the major sterol efflux transporter of enterocytes, than the knockout counterparts, suggesting that the heterodimer confers additional rapid BBM-to-lumen cholesterol efflux in response to NPC1L1 inhibition. The observed framework for intestinal cholesterol fluxes may provide ways to

  11. Experimental study and modelisation of a pulse tube refrigerator

    International Nuclear Information System (INIS)

    Ravex, A.; Rolland, P.; Liang, J.

    1992-01-01

    A test bench for pulse tube refrigerator characterization has been built. In various configurations (basic pulse tube, orifice pulse tube and double inlet pulse tube), the ultimate temperature and the cooling power have been measured as a function of pressure wave amplitude and frequency for various geometries. A lowest temperature of 28 K has been achieved in a single staged double inlet configuration. A modelisation taking into account wall heat pumping, enthalpy flow and regenerator inefficiency is under development. Preliminary calculation results are compared with experimental data

  12. The 1.7 Å resolution structure of At2g44920, a pentapeptide-repeat protein in the thylakoid lumen of Arabidopsis thaliana

    International Nuclear Information System (INIS)

    Ni, Shuisong; McGookey, Michael E.; Tinch, Stuart L.; Jones, Alisha N.; Jayaraman, Seetharaman; Tong, Liang; Kennedy, Michael A.

    2011-01-01

    The crystal structure of At2g44920, a pentapeptide repeat protein (PRP) from Arabidopsis thaliana, has been determined at 1.7 Å resolution. The structure represents the first PRP protein whose subcellular localization has been experimentally confirmed to be the thylakoid lumen of a plant species. At2g44920 belongs to a diverse family (Pfam PF00805) of pentapeptide-repeat proteins (PRPs) that are present in all known organisms except yeast. PRPs contain at least eight tandem-repeating sequences of five amino acids with an approximate consensus sequence (STAV)(D/N)(L/F)(S/T/R)(X). Recent crystal structures show that PRPs adopt a highly regular four-sided right-handed β-helical structure consisting mainly of type II and type IV β-turns, sometimes referred to as a repeated five-residue (or Rfr) fold. Among sequenced genomes, PRP genes are most abundant in cyanobacteria, leading to speculation that PRPs play an important role in the unique lifestyle of photosynthetic cyanobacteria. Despite the recent structural characterization of several cyanobacterial PRPs, most of their functions remain unknown. Plants, whose chloroplasts are of cyanobacterial origin, have only four PRP genes in their genomes. At2g44920 is one of three PRPs located in the thylakoid lumen. Here, the crystal structure of a double methionine mutant of residues 81–224 of At2g44920, the naturally processed fragment of one of its full-length isoforms, is reported at 1.7 Å resolution. The structure of At2g44920 consists of the characteristic Rfr fold with five uninterrupted coils made up of 25 pentapeptide repeats and α-helical elements capping both termini. A disulfide bridge links the two α-helices with a conserved loop between the helical elements at its C-terminus. This structure represents the first structure of a PRP protein whose subcellular location has been experimentally confirmed to be the thylakoid lumen in a plant species

  13. Volumetric analysis demonstrates that true and false lumen remodeling persists for 12 months after thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Ga-Young Suh, PhD

    2016-09-01

    Full Text Available A 62-year-old man underwent an elephant trunk procedure followed by thoracic endovascular aortic repair (TEVAR. Computed tomography angiography-based models were built to quantify volume of the whole aorta and true and false lumens preoperatively, before TEVAR, after TEVAR, and at follow-up at 3, 6, and 12 months. With TEVAR, descending aortic true lumen volume increased by 54%, then increased additionally by 60% during 12 months. The descending aortic false lumen volume regressed continuously for 12 months following TEVAR, with the most rapid rate from 6 to 12 months at 16 cm3/month. TEVAR immediately increased true lumen volume and continued to remodel the true and false lumens throughout the following 12 months.

  14. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  15. Feeding tube - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007235.htm Feeding tube - infants To use the sharing features on this page, please enable JavaScript. A feeding tube is a small, soft, plastic tube placed ...

  16. Lumen modifications

    Science.gov (United States)

    Rebecca E. Ibach; W. Dale Ellis

    2005-01-01

    Wood is used to produce many products (structural and nonstructural) for applications in which its natural properties are adequate. With the decrease of wood availability and the increase of less durable, younger and faster-growing trees, it is possible to modify wood in various ways to improve the properties, depending on the ultimate application. Wood- polymer...

  17. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

    Science.gov (United States)

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary

    2013-01-01

    Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.

  18. Tube formation by complex cellular processes in Ciona intestinalis notochord.

    Science.gov (United States)

    Dong, Bo; Horie, Takeo; Denker, Elsa; Kusakabe, Takehiro; Tsuda, Motoyuki; Smith, William C; Jiang, Di

    2009-06-15

    In the course of embryogenesis multicellular structures and organs are assembled from constituent cells. One structural component common to many organs is the tube, which consists most simply of a luminal space surrounded by a single layer of epithelial cells. The notochord of ascidian Ciona forms a tube consisting of only 40 cells, and serves as a hydrostatic "skeleton" essential for swimming. While the early processes of convergent extension in ascidian notochord development have been extensively studied, the later phases of development, which include lumen formation, have not been well characterized. Here we used molecular markers and confocal imaging to describe tubulogenesis in the developing Ciona notochord. We found that during tubulogenesis each notochord cell established de novo apical domains, and underwent a mesenchymal-epithelial transition to become an unusual epithelial cell with two opposing apical domains. Concomitantly, extracellular luminal matrix was produced and deposited between notochord cells. Subsequently, each notochord cell simultaneously executed two types of crawling movements bi-directionally along the anterior/posterior axis on the inner surface of notochordal sheath. Lamellipodia-like protrusions resulted in cell lengthening along the anterior/posterior axis, while the retraction of trailing edges of the same cell led to the merging of the two apical domains. As a result, the notochord cells acquired endothelial-like shape and formed the wall of the central lumen. Inhibition of actin polymerization prevented the cell movement and tube formation. Ciona notochord tube formation utilized an assortment of common and fundamental cellular processes including cell shape change, apical membrane biogenesis, cell/cell adhesion remodeling, dynamic cell crawling, and lumen matrix secretion.

  19. Intraluminal erosion of laparoscopic gastric band tubing into duodenum with recurrent port-site infections.

    Science.gov (United States)

    Cintolo, Jessica A; Levine, Marc S; Huang, Stephanie; Dumon, Kristoffel

    2012-01-01

    Intraluminal erosion of a laparoscopic gastric band into the stomach has been reported as a complication of laparoscopic adjustable gastric banding. To our knowledge, however, intraluminal erosion of the band tubing into the duodenum has not been described. We report a 46-year-old man in whom a laparoscopic adjustable gastric band tubing eroded into the duodenal lumen, causing recurrent port-site infections. This complication was diagnosed on upper endoscopy and also, in retrospect, on an upper gastrointestinal barium study and computed tomography. The patient underwent surgical removal of the band and tubing, with a primary duodenal repair, and made a complete recovery without complications. Erosion of laparoscopic band tubing into the duodenum should be included in the differential diagnosis for recurrent port-site infections after laparoscopic adjustable gastric banding. Radiographic or endoscopic visualization of the intraluminal portion of the tubing may be required for confirmation. Definitive treatment of this complication entails surgical removal of the tubing from the duodenum.

  20. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  1. Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The lumen depreciation and color shift of 38 different lamps (32 LED, 2 CFL, 1 ceramic metal halide [CMH], 3 halogen) were monitored in a specially developed automated long-term test apparatus (ALTA2) for nearly 14,000 hours. Five samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at a target ambient temperature between 44°C and 45°C.

  2. Anesthetic Management of Patients Undergoing Right Lung Surgery After Left Upper Lobectomy: Selection of Tubes for One-Lung Ventilation (OLV) and Oxygenation During OLV.

    Science.gov (United States)

    Kawagoe, Izumi; Hayashida, Masakazu; Suzuki, Kenji; Kitamura, Yoshitaka; Oh, Shiaki; Satoh, Daizoh; Inada, Eiichi

    2016-08-01

    To investigate anesthesia management in patients undergoing right lung surgery after a previous left upper lobectomy (LUL) that may require special precautions since angulation of the left bronchus can hamper correct placement of a left-sided double-lumen tube (DLT), and one-lung ventilation (OLV) depending solely on the left lower lobe may lead to inadequate oxygenation. A retrospective data analysis. Single university hospital. Patients underwent right lung surgery after previous LUL. None. Anesthesia management was investigated in 18 patients who underwent right lung surgery following LUL. All intubation procedures were performed under bronchoscopic guidance to prevent airway trauma. OLV could be achieved with a left-sided DLT in 12 patients, while tubes other than this were required in 6 patients, including a right-sided DLT (n = 3) and a bronchial blocker (n = 3). The presence or absence of remarkable bronchial angulation, characterized by a combination of a wide (>140°) angle between the trachea and left main bronchus and a narrow (right lung surgery after LUL. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Microbes vs. chemistry in the origin of the anaerobic gut lumen.

    Science.gov (United States)

    Friedman, Elliot S; Bittinger, Kyle; Esipova, Tatiana V; Hou, Likai; Chau, Lillian; Jiang, Jack; Mesaros, Clementina; Lund, Peder J; Liang, Xue; FitzGerald, Garret A; Goulian, Mark; Lee, Daeyeon; Garcia, Benjamin A; Blair, Ian A; Vinogradov, Sergei A; Wu, Gary D

    2018-04-17

    The succession from aerobic and facultative anaerobic bacteria to obligate anaerobes in the infant gut along with the differences between the compositions of the mucosally adherent vs. luminal microbiota suggests that the gut microbes consume oxygen, which diffuses into the lumen from the intestinal tissue, maintaining the lumen in a deeply anaerobic state. Remarkably, measurements of luminal oxygen levels show nearly identical pO 2 (partial pressure of oxygen) profiles in conventional and germ-free mice, pointing to the existence of oxygen consumption mechanisms other than microbial respiration. In vitro experiments confirmed that the luminal contents of germ-free mice are able to chemically consume oxygen (e.g., via lipid oxidation reactions), although at rates significantly lower than those observed in the case of conventionally housed mice. For conventional mice, we also show that the taxonomic composition of the gut microbiota adherent to the gut mucosa and in the lumen throughout the length of the gut correlates with oxygen levels. At the same time, an increase in the biomass of the gut microbiota provides an explanation for the reduction of luminal oxygen in the distal vs. proximal gut. These results demonstrate how oxygen from the mammalian host is used by the gut microbiota, while both the microbes and the oxidative chemical reactions regulate luminal oxygen levels, shaping the composition of the microbial community throughout different regions of the gut.

  4. New model of universal gas-filled neutron tube

    International Nuclear Information System (INIS)

    Bespalov, D.F.; Bessarabskii, I.G.; Voitsik, L.R.; Mints, A.Z.

    1985-01-01

    The UNG-1 gas-filled neutron tube is serially produced. In type UNG neutron generators, the tube operates in the pulsed mode in the high voltage doubling circuit arrangement. During extended operation, its advantages were discovered: long operating time, fairly stable neutron yield, and simplicity of use and operation. However, the mean neutron yield (approx.10 7 s -1 ) generated by the tube in the optimal mode at the present time proved to be inadequate in solving numerous geophysical problems. So a model of a neutron tube, model UNG-2, was designed, ensuring an enhanced neutron yield of 10 8 s -1 in the continuous-operating mode. When the tube is connected to the high voltage doubling circuit, the mean neutron yield is only somewhat in excess of the neutron yield from the UNG-1 tube

  5. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    Energy Technology Data Exchange (ETDEWEB)

    Palmucci, S., E-mail: spalmucci@sirm.org; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-15

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm{sup 2}/sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm{sup 2}/s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm{sup 2}/s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm{sup 2}/s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to

  6. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    International Nuclear Information System (INIS)

    Palmucci, S.; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-01

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm 2 /sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm 2 /s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm 2 /s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm 2 /s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to investigate better

  7. Glycogen distribution in porcine fallopian tube epithelium during the estrus cycle.

    Science.gov (United States)

    Gregoraszczuk, E Ł; Cała, M; Witkowska, E

    2000-01-01

    Histochemical features of two different parts of the porcine Fallopian tube have been studied, with special reference to cyclic changes in the distribution of glycogen particles. Porcine Fallopian tubes were obtained from a local slaughterhouse. Slides were studied under light microscopy utilising histological and histochemical techniques. The most striking feature during the periovulatory stage of the estrus cycle was the occurrence of glycogen granules in the apical cytoplasm of epithelial cells in both the ampulla and isthmus of the Fallopian tubes. In the isthmus, cells containing numerous granules of polysaccharides aggregated into areas of different sizes were noted after ovulation. During the midluteal phase their number was minimal or were even absent. In the ampula typical extrusion of secretory granules and nuclei protruding into the tubal lumen was visible after ovulation. In the luteal phase a lot of nuclei protruded into the tubal lumen and some free in the lumen were noted. It is possible that glycogen in the preovulatory stage functions as a source of energy for ciliary movement and as a nourishment for the ovum. In the isthmus large number of aggregated glycogen particles was observed also after ovulation. In this stage of the cycle, numerous granules of polysaccharide aggregated in isthmus epithelium could be the major energy source for embriogenesis when the embryo travels down the Fallopian tubes, during the early cleavage stage.

  8. Bender/Coiler for Tubing

    Science.gov (United States)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  9. Primary carcinoma of the Fallopian tubes

    International Nuclear Information System (INIS)

    Escalona Veloz, Rafael; Lopez Rodriguez, Caridad; Nunnez Quintana, Adrian; Rizo Reve, Rafael

    2010-01-01

    The clinical case of a 53 year old patient with history of vaginal bleeding for possible uterine fibroma is described. A total hysterectomy with double ooferectomia was performed. The complementary tests results, including the biopsy, confirmed the presence of a primary carcinoma of the right Fallopian tube. A radiotherapy and follow up were indicated in 'Conrado Benitez' Oncology Hospital from Santiago de Cuba

  10. Establishment of a semi-biological phantom model for the study of the effect of dose reducing measures on radiation-induced DNA double strand breaks in CT using the example of risk organ based tube current modulation; Etablierung eines semibiologischen Phantommodells zur Untersuchung des Effekts dosisreduzierender Massnahmen auf strahleninduzierte DNA-Doppelstrangbrueche in der CT am Beispiel der risikoorganbasierten Roehrenstrommodulation

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Matthias

    2013-12-12

    The number of computed tomography (CT) examinations has been rising during the last decades. Therefore techniques for dose reduction receive increasing attention. Risk organ-based tube current modulation (RCM) in CT is a new approach and works by lowering the tube current, while the tube is in front of the patient's body. Therefore it should lead to a dose reduction for radiosensitive organs like the female breast, the eye lenses and the thyroid gland. Biological radiation effects cannot be estimated by physical-based dose measurements. γ-H2AX is a sensitive marker for the determination of x-ray induced DNA double-strand breaks (DSB). Hence the aim of this study was to establish a biological phantom model based on the γ-H2AX immunofluorescence microscopy method and to investigate the effect of RCM on radiation induced DNA damages. The γ-H2AX method is based on the phosphorylation of the histone variant H2AX. The phosphorylated histone γ-H2AX can be visualised using antibodies and is specific for radiation induced DSB. Blood lymphocytes from healthy volunteers, skin fibroblasts (LN) and mammary epithelial cells (HMEpC-p) were placed in different positions of an Alderson-phantom and exposed to x-rays using a 128-slice dual-source CT scanner. Standard head, neck and chest-CT scan protocols either with or without risk-organ based tube current modulation were used. RCM reduces the tube current to 20 percent at an angle of 130 degree anterior to the body, whereas tube current is increased at an angle of 230 degree posterior to the body. Afterwards cells were isolated, fixed on slides und stained with specific primary γ-H2AX antibodies and fluorescent secondary antibodies. Tiny green dots (named foci) can be detected and quantified with a fluorescence microscope and represent distinct DSB. Non-irradiated samples served as controls and CT-induced DSB were calculated by subtraction of pre- from post-exposure values. In this study a semibiological phantom model

  11. Distinct patterns of inflammation in the airway lumen and bronchial mucosa of children with cystic fibrosis.

    Science.gov (United States)

    Regamey, Nicolas; Tsartsali, Lemonia; Hilliard, Tom N; Fuchs, Oliver; Tan, Hui-Leng; Zhu, Jie; Qiu, Yu-Sheng; Alton, Eric W F W; Jeffery, Peter K; Bush, Andrew; Davies, Jane C

    2012-02-01

    Studies in cystic fibrosis (CF) generally focus on inflammation present in the airway lumen. Little is known about inflammation occurring in the airway wall, the site ultimately destroyed in end-stage disease. To test the hypothesis that inflammatory patterns in the lumen do not reflect those in the airway wall of children with CF. Bronchoalveolar lavage (BAL) fluid and endobronchial biopsies were obtained from 46 children with CF and 16 disease-free controls. BAL cell differential was assessed using May-Gruenwald-stained cytospins. Area profile counts of bronchial tissue immunopositive inflammatory cells were determined. BAL fluid from children with CF had a predominance of neutrophils compared with controls (median 810×10(3)/ml vs 1×10(3)/ml, p<0.0001). In contrast, subepithelial bronchial tissue from children with CF was characterised by a predominance of lymphocytes (median 961 vs 717 cells/mm(2), p=0.014), of which 82% were (CD3) T lymphocytes. In chest exacerbations, BAL fluid from children with CF had more inflammatory cells of all types compared with those with stable disease whereas, in biopsies, only the numbers of lymphocytes and macrophages, but not of neutrophils, were higher. A positive culture of Pseudomonas aeruginosa was associated with higher numbers of T lymphocytes in subepithelial bronchial tissue (median 1174 vs 714 cells/mm(2), p=0.029), but no changes were seen in BAL fluid. Cell counts in BAL fluid and biopsies were positively correlated with age but were unrelated to each other. The inflammatory response in the CF airway is compartmentalised. In contrast to the neutrophil-dominated inflammation present in the airway lumen, the bronchial mucosa is characterised by the recruitment and accumulation of lymphocytes.

  12. Contura Multi-Lumen Balloon Breast Brachytherapy Catheter: Comparative Dosimetric Findings of a Phase 4 Trial

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Douglas W., E-mail: darthur@mcvh-vcu.edu [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Vicini, Frank A. [Michigan Healthcare Professionals/21st Century Oncology, Farmington Hills, Michigan (United States); Todor, Dorin A. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Julian, Thomas B. [Allegheny General Hospital, Temple University School of Medicine, Pittsburgh, Pennsylvania (United States); Cuttino, Laurie W.; Mukhopadhyay, Nitai D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States)

    2013-06-01

    Purpose: Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Methods and Materials: Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥95% of the prescribed dose (PD) covering ≥95% of the target volume (TV); maximum skin dose ≤125% of the PD; maximum rib dose ≤145% of the PD; and V150 ≤50 cc and V200 ≤10 cc. Results: Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Conclusions: Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals.

  13. Contura Multi-Lumen Balloon breast brachytherapy catheter: comparative dosimetric findings of a phase 4 trial.

    Science.gov (United States)

    Arthur, Douglas W; Vicini, Frank A; Todor, Dorin A; Julian, Thomas B; Cuttino, Laurie W; Mukhopadhyay, Nitai D

    2013-06-01

    Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥ 95% of the prescribed dose (PD) covering ≥ 95% of the target volume (TV); maximum skin dose ≤ 125% of the PD; maximum rib dose ≤ 145% of the PD; and V150 ≤50 cc and V200 ≤ 10 cc. Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P ≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals. Copyright © 2013 Elsevier Inc. All rights

  14. Assessment of lumen degradation and remaining useful life of LEDs using particle filter

    Energy Technology Data Exchange (ETDEWEB)

    Lall, Pradeep [Auburn Univ., AL (United States); Zhang, Hao [Auburn Univ., AL (United States); Davis, Lynn [Auburn Univ., AL (United States)

    2013-07-16

    With the development of light-emitting diode (LED) technology, light emitting diodes system is becoming a popular light source in daily life and industry area. It has shown that Led from same factory and work under same working condition, may have significantly different behavior. Therefore, it is very important to learn the fail mechanisms, especially in the case of safety critical and harsh environment application. This paper focus on a prognostic health management (PHM) method based on the measurement of forward voltage and forward current of bare LED under harsh environment. In this paper, experiment has been done with ten samples. Ten pristine bare LEDs have been tested at 85°C while simultaneously being subjected to 85% humid environment. Pulse width modulation (PWM) control method has been employed to drive the bare LED in order to reduce the heat effect caused by forward current and high frequency (300HZ) data acquisition has been used to measure the peak forward voltage and forward current. Test to failure (lumen drops to 70 percent) data has been measured to study the effects of high temperature and humid environment loadings on the bare LED. Also, solid state cooling method with peltier cooler has been used to control the temperature of LED in the integrating sphere when take the measurement of lumen flux. The shift of forward voltage forward current curve and lumen degradation has been recorded to help build the fail model and predicted the remaining useful life. In this method, particle filter has been employed to predict the remaining useful life (RUL) of the bare LED and give us a whole picture how Led system fails. Result shows that predication of remaining useful life of Led, made by the particle filter model works under reasonable limit, and hence this method can be employed to predict the failure of Led caused by thermal and humid stress under harsh environment.

  15. Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches.

    Science.gov (United States)

    Araki, Tadashi; Kumar, P Krishna; Suri, Harman S; Ikeda, Nobutaka; Gupta, Ajay; Saba, Luca; Rajan, Jeny; Lavra, Francesco; Sharma, Aditya M; Shafique, Shoaib; Nicolaides, Andrew; Laird, John R; Suri, Jasjit S

    2016-07-01

    The degree of stenosis in the carotid artery can be predicted using automated carotid lumen diameter (LD) measured from B-mode ultrasound images. Systolic velocity-based methods for measurement of LD are subjective. With the advancement of high resolution imaging, image-based methods have started to emerge. However, they require robust image analysis for accurate LD measurement. This paper presents two different algorithms for automated segmentation of the lumen borders in carotid ultrasound images. Both algorithms are modeled as a two stage process. Stage one consists of a global-based model using scale-space framework for the extraction of the region of interest. This stage is common to both algorithms. Stage two is modeled using a local-based strategy that extracts the lumen interfaces. At this stage, the algorithm-1 is modeled as a region-based strategy using a classification framework, whereas the algorithm-2 is modeled as a boundary-based approach that uses the level set framework. Two sets of databases (DB), Japan DB (JDB) (202 patients, 404 images) and Hong Kong DB (HKDB) (50 patients, 300 images) were used in this study. Two trained neuroradiologists performed manual LD tracings. The mean automated LD measured was 6.35 ± 0.95 mm for JDB and 6.20 ± 1.35 mm for HKDB. The precision-of-merit was: 97.4 % and 98.0 % w.r.t to two manual tracings for JDB and 99.7 % and 97.9 % w.r.t to two manual tracings for HKDB. Statistical tests such as ANOVA, Chi-Squared, T-test, and Mann-Whitney test were conducted to show the stability and reliability of the automated techniques.

  16. The microbiota mediates pathogen clearance from the gut lumen after non-typhoidal Salmonella diarrhea.

    Directory of Open Access Journals (Sweden)

    Kathrin Endt

    Full Text Available Many enteropathogenic bacteria target the mammalian gut. The mechanisms protecting the host from infection are poorly understood. We have studied the protective functions of secretory antibodies (sIgA and the microbiota, using a mouse model for S. typhimurium diarrhea. This pathogen is a common cause of diarrhea in humans world-wide. S. typhimurium (S. tm(att, sseD causes a self-limiting gut infection in streptomycin-treated mice. After 40 days, all animals had overcome the disease, developed a sIgA response, and most had cleared the pathogen from the gut lumen. sIgA limited pathogen access to the mucosal surface and protected from gut inflammation in challenge infections. This protection was O-antigen specific, as demonstrated with pathogens lacking the S. typhimurium O-antigen (wbaP, S. enteritidis and sIgA-deficient mice (TCRβ(-/-δ(-/-, J(H (-/-, IgA(-/-, pIgR(-/-. Surprisingly, sIgA-deficiency did not affect the kinetics of pathogen clearance from the gut lumen. Instead, this was mediated by the microbiota. This was confirmed using 'L-mice' which harbor a low complexity gut flora, lack colonization resistance and develop a normal sIgA response, but fail to clear S. tm(att from the gut lumen. In these mice, pathogen clearance was achieved by transferring a normal complex microbiota. Thus, besides colonization resistance ( = pathogen blockage by an intact microbiota, the microbiota mediates a second, novel protective function, i.e. pathogen clearance. Here, the normal microbiota re-grows from a state of depletion and disturbed composition and gradually clears even very high pathogen loads from the gut lumen, a site inaccessible to most "classical" immune effector mechanisms. In conclusion, sIgA and microbiota serve complementary protective functions. The microbiota confers colonization resistance and mediates pathogen clearance in primary infections, while sIgA protects from disease if the host re-encounters the same pathogen. This has

  17. Prediction of L70 lumen maintenance and chromaticity for LEDs using extended Kalman filter models

    Energy Technology Data Exchange (ETDEWEB)

    Lall, Pradeep; Wei, Junchao; Davis, Lynn

    2013-09-30

    Solid-state lighting (SSL) luminaires containing light emitting diodes (LEDs) have the potential of seeing excessive temperatures when being transported across country or being stored in non-climate controlled warehouses. They are also being used in outdoor applications in desert environments that see little or no humidity but will experience extremely high temperatures during the day. This makes it important to increase our understanding of what effects high temperature exposure for a prolonged period of time will have on the usability and survivability of these devices. Traditional light sources “burn out” at end-of-life. For an incandescent bulb, the lamp life is defined by B50 life. However, the LEDs have no filament to “burn”. The LEDs continually degrade and the light output decreases eventually below useful levels causing failure. Presently, the TM-21 test standard is used to predict the L70 life of LEDs from LM-80 test data. Several failure mechanisms may be active in a LED at a single time causing lumen depreciation. The underlying TM-21 Model may not capture the failure physics in presence of multiple failure mechanisms. Correlation of lumen maintenance with underlying physics of degradation at system-level is needed. In this paper, Kalman Filter (KF) and Extended Kalman Filters (EKF) have been used to develop a 70-percent Lumen Maintenance Life Prediction Model for LEDs used in SSL luminaires. Ten-thousand hour LM-80 test data for various LEDs have been used for model development. System state at each future time has been computed based on the state space at preceding time step, system dynamics matrix, control vector, control matrix, measurement matrix, measured vector, process noise and measurement noise. The future state of the lumen depreciation has been estimated based on a second order Kalman Filter model and a Bayesian Framework. The measured state variable has been related to the underlying damage using physics-based models. Life

  18. Severe complications caused by dissolution of latex with consequent self-disintegration of esophageal plastic tubes.

    Science.gov (United States)

    Löser, C

    2000-09-01

    A case of decisive material degeneration of an esophageal Celestin tube is described: a 50-year-old man with adenocarcinoma of the distal esophagus received a Celestin tube for palliative endoscopic treatment and 8 months later presented with suddenly occurring complete dysphagia. Dissolution of the latex layer in the proximal as well as the distal part of the tube had caused self-disintegration of the Celestin tube and had liberated the monofilament nylon coil which completely obstructed the lumen of the tube. Endoscopic tube removal was only possible by careful attachment of a balloon catheter and peroral extraction after insufflation with contrast medium up to 5 atm. A Medline-based review of the literature revealed different but predominantly severe complications (perforation, hemorrhage, obstruction, and peritonitis) based on material fatigue of the latex layer in esophageal Celestin tubes. At least 6 months after placement of a Celestin tube, regular fluoroscopic controls should be performed to detect early disintegration of the tube. Indication for the placement of Celestin tubes in patients with benign esophageal strictures and longer life expectancy should be assessed very critically.

  19. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  20. Pressure tube type reactors

    International Nuclear Information System (INIS)

    Komada, Masaoki.

    1981-01-01

    Purpose: To increase the safety of pressure tube type reactors by providing an additional ECCS system to an ordinary ECCS system and injecting heavy water in the reactor core tank into pressure tubes upon fractures of the tubes. Constitution: Upon fractures of pressure tubes, reduction of the pressure in the fractured tubes to the atmospheric pressure in confirmed and the electromagnetic valve is operated to completely isolate the pressure tubes from the fractured portion. Then, the heavy water in the reactor core tank flows into and spontaneously recycles through the pressure tubes to cool the fuels in the tube to prevent their meltdown. By additionally providing the separate ECCS system to the ordinary ECCS system, fuels can be cooled upon loss of coolant accidents to improve the safety of the reactors. (Moriyama, K.)

  1. Gastrostomy feeding tube - bolus

    Science.gov (United States)

    Feeding - gastrostomy tube - bolus; G-tube - bolus; Gastrostomy button - bolus; Bard Button - bolus; MIC-KEY - bolus ... KEY, 3 to 8 weeks after surgery. These feedings will help your child grow strong and healthy. ...

  2. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  3. Neural Tube Defects

    Science.gov (United States)

    Neural tube defects are birth defects of the brain, spine, or spinal cord. They happen in the ... that she is pregnant. The two most common neural tube defects are spina bifida and anencephaly. In ...

  4. Passive heat transfer enhancement in 3D corrugated tube

    DEFF Research Database (Denmark)

    Navickaité, Kristina; Engelbrecht, Kurt; Bahl, Christian

    transfer and fluid flow with a constant wall temperature and total pressure drop. The governing equations for these problems were solved using the Finite Element Method. The results of numerical modelling show significant increase in NTU for double corrugated tubes compared to a circular tube. The friction......An innovative hydraulic design was studied for corrugated tube geometry for a heat exchanger. An ellipse based double corrugation was used as a concept of the geometry. The hydraulic diameter (Dh) is maintained over the tube length while the shape of the cross section varies continuously along...... the flow direction. 38 corrugated tubes with a Dh of 5 mm were studied numerically with corrugation heights from 0.23 to 0.69 mm and corrugation periods from 5 to 50 mm for laminar flow with water. Computational fluid dynamics (CFD) is used as a tool to study the effect of corrugation geometry on heat...

  5. SAS-6 assembly templated by the lumen of cartwheel-less centrioles precedes centriole duplication.

    Science.gov (United States)

    Fong, Chii Shyang; Kim, Minhee; Yang, T Tony; Liao, Jung-Chi; Tsou, Meng-Fu Bryan

    2014-07-28

    Centrioles are 9-fold symmetric structures duplicating once per cell cycle. Duplication involves self-oligomerization of the centriolar protein SAS-6, but how the 9-fold symmetry is invariantly established remains unclear. Here, we found that SAS-6 assembly can be shaped by preexisting (or mother) centrioles. During S phase, SAS-6 molecules are first recruited to the proximal lumen of the mother centriole, adopting a cartwheel-like organization through interactions with the luminal wall, rather than via their self-oligomerization activity. The removal or release of luminal SAS-6 requires Plk4 and the cartwheel protein STIL. Abolishing either the recruitment or the removal of luminal SAS-6 hinders SAS-6 (or centriole) assembly at the outside wall of mother centrioles. After duplication, the lumen of engaged mother centrioles becomes inaccessible to SAS-6, correlating with a block for reduplication. These results lead to a proposed model that centrioles may duplicate via a template-based process to preserve their geometry and copy number. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Utility of dark-lumen MR colonography for the assessment of extra-colonic organs

    International Nuclear Information System (INIS)

    Ajaj, Waleed; Goyen, Mathias; Ruehm, Stefan G.; Ladd, Susanne C.; Gerken, Guido

    2007-01-01

    The aim of the study was to evaluate the utility of dark-lumen MR colonography (MRC) for the assessment of extra-colonic organs. Three hundred seventy-five subjects with suspected colonic disease underwent a complete MRC examination. MRC data were evaluated by two radiologists in a blinded fashion. In addition to the large bowel, the extra-intestinal organs from the lung bases to the pelvis were assessed for the presence of pathologies. All findings were divided into known or unknown findings and therapeutically relevant or irrelevant findings. If deemed necessary, other diagnostic imaging tests to further assess those findings were performed. In total, 510 extra-colonic findings were found in 260 (69%) of the 375 subjects. Known extra-colonic findings were found in 140 subjects (54%) and unknown findings in 120 subjects (46%). Thirty-one (12%) of the 260 subjects had therapeutically relevant findings (45 findings); 229 patients (88%) had irrelevant findings (465 findings). Dark-lumen MRC is a useful tool not only for the assessment of the entire colon, but also for the evaluation of extra-colonic organs. Thus, intra- and extra-colonic pathologies can be diagnosed within the same examination. (orig.)

  7. Proteomics of the chloroplast: systematic identification and targeting analysis of lumenal and peripheral thylakoid proteins

    DEFF Research Database (Denmark)

    Peltier, J B; Friso, G; Kalume, D E

    2000-01-01

    The soluble and peripheral proteins in the thylakoids of pea were systematically analyzed by using two-dimensional electrophoresis, mass spectrometry, and N-terminal Edman sequencing, followed by database searching. After correcting to eliminate possible isoforms and post-translational modificati......The soluble and peripheral proteins in the thylakoids of pea were systematically analyzed by using two-dimensional electrophoresis, mass spectrometry, and N-terminal Edman sequencing, followed by database searching. After correcting to eliminate possible isoforms and post......-translational modifications, we estimated that there are at least 200 to 230 different lumenal and peripheral proteins. Sixty-one proteins were identified; for 33 of these proteins, a clear function or functional domain could be identified, whereas for 10 proteins, no function could be assigned. For 18 proteins, no expressed...... sequence tag or full-length gene could be identified in the databases, despite experimental determination of a significant amount of amino acid sequence. Nine previously unidentified proteins with lumenal transit peptides are presented along with their full-length genes; seven of these proteins possess...

  8. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  9. Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques

    Energy Technology Data Exchange (ETDEWEB)

    Falcão, João L. A. A.; Falcão, Breno A. A. [Heart Institute (InCor), University of São Paulo Medical School (USP), São Paulo, SP (Brazil); Gurudevan, Swaminatha V. [Cedars-Sinai Heart Institute, Los Angeles, California, USA (United States); Campos, Carlos M.; Silva, Expedito R.; Kalil-Filho, Roberto; Rochitte, Carlos E.; Shiozaki, Afonso A.; Coelho-Filho, Otavio R.; Lemos, Pedro A. [Heart Institute (InCor), University of São Paulo Medical School (USP), São Paulo, SP (Brazil)

    2015-04-15

    The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.

  10. Comparison of different ligature materials used for T-tube esophageal exclusion.

    Science.gov (United States)

    Lee, Y C; Luh, S P; Tsai, C C; Hsu, H C; Chu, S H

    1992-03-01

    Four different ligature materials--plain catgut, chromic catgut, dexon and silk--were used for ligature of the distal arm during T-tube exclusion of the cervical esophagus in 12 dogs. Ligature by plain catgut was maintained for only a short period, but the duration of esophageal occlusion with the other three ligature materials was around 10 days. Ligated esophageal segments were examined grossly and histologically two months after the procedure. The diameter of the esophageal lumen in the ligated segments had become smaller compared with the neighboring normal esophageal lumen. The most prominent histologic changes were atrophy and fibrosis of the muscle coat, vessel congestion and inflammatory cell infiltration in the ligated segments. These tissue reactions were more severe in the chromic catgut and silk ligatures. Among the 11 evaluable dogs, four had symptoms of dysphagia after removal of the T-tube. All four dogs had a sinus discharge and granuloma formation at the T-tube esophagostoma. The diameter of the esophageal lumen was more constricted in dogs with dysphagia. Among the four ligature materials, dexon had the advantages of a long duration of occlusion, less tissue fibrosis and little sequel of esophageal stenosis, making it the most suitable for ligature during esophageal exclusion.

  11. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  12. Comparison of the effect of lignocaine instilled through the endotracheal tube and intravenous lignocaine on the extubation response in patients undergoing craniotomy with skull pins: A randomized double blind clinical trial

    Directory of Open Access Journals (Sweden)

    Smitha Elizabeth George

    2013-01-01

    Full Text Available Background: A desirable combination of smooth extubation and an awake patient after neurosurgical procedures is difficult to achieve in patients with skull pins. Lignocaine instilled into endotracheal tube has been reported to suppress cough by a local mucosal anesthetizing effect. We aimed to evaluate if this effect will last till extubation, if given before pin removal. Materials and Methods: A total of 114 patients undergoing elective craniotomy were divided into three groups and were given 1 mg/kg of intravenous (IV, 2% lignocaine (Group 1, placebo (Group 2 and 1 mg/kg of 2% lignocaine sprayed down the endotracheal tube (Group 3 before skull pin removal. The effectiveness of each to blunt extubation response was compared. Plasma levels of lignocaine were measured 10 min after administration of the study drug and at extubation. Sedation scores were noted, immediately after extubation and 10 min later. Results: Two percent of lignocaine instilled through endotracheal route was not superior to the IV route or placebo in attenuating cough or hemodynamic response at extubation when given 20-30 min before extubation. The plasma levels of lignocaine (0.8 μg/ml were not high enough even at the end of 10 min to have a suppressive effect on cough if given IV or intratracheally (IT. Lignocaine did not delay awakening in these groups. Conclusion: IT lignocaine in the dose of 1 mg/kg does not prevent cough at extubation if given 20-30 min before extubation. If the action is by a local mucosal anesthetizing effect, it does not last for 20-30 min to cover the period from pin removal to extubation.

  13. Heat exchanger tube tool

    International Nuclear Information System (INIS)

    Gugel, G.

    1976-01-01

    Certain types of heat-exchangers have tubes opening through a tube sheet to a manifold having an access opening offset from alignment with the tube ends. A tool for inserting a device, such as for inspection or repair, is provided for use in such instances. The tool is formed by a flexible guide tube insertable through the access opening and having an inner end provided with a connector for connection with the opening of the tube in which the device is to be inserted, and an outer end which remains outside of the chamber, the guide tube having adequate length for this arrangement. A flexible transport hose for internally transporting the device slides inside of the guide tube. This hose is long enough to slide through the guide tube, into the heat-exchanger tube, and through the latter to the extent required for the use of the device. The guide tube must be bent to reach the end of the heat-exchanger tube and the latter may be constructed with a bend, the hose carrying anit-friction elements at interspaced locations along its length to make it possible for the hose to negotiate such bends while sliding to the location where the use of the device is required

  14. Preparation of lumen-loaded kenaf pulp with magnetite (Fe{sub 3}O{sub 4})

    Energy Technology Data Exchange (ETDEWEB)

    Zakaria, S.; Ong, B.H.; Ahmad, S.H.; Abdullah, M.; Yamauchi, T

    2005-02-15

    Magnetic pulps were prepared from unbleached kenaf (hibiscus cannabinus L.) kraft pulps. Fe{sub 3}O{sub 4} or magnetite powder was used to load into the pulp's lumen and pit. Aluminum sulphate [Al{sub 2}(SO{sub 4}){sub 3}] (alum) and polyethylenimine (PEI), both mainly function as retention aid were used throughout the experiment and found to be beneficial in the preparation of this magnetic pulps. The ash content method was used to determine the amount of magnetite retained in the lumen and pit. The utilization of PEI up to 2% per pulp fibres was found to be the best result on lumen loading. The deposition of magnetite powder in lumen and pit is found decrease as the addition of PEI used is more than 2% per pulp fibres. Scanning electron microscope (SEM) clearly shows the distribution of magnetite deposited in the lumen. Tensile index and folding endurance of the loaded fibre decreased slightly as the percentage of loading pigment increased.

  15. Dual-Lumen Chest Port Infection Rates in Patients with Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bos, Aaron, E-mail: abos1210@gmail.com; Ahmed, Osman [University of Chicago Medical Center (United States); Jilani, Danial [Wright State University Boonshoft School of Medicine (United States); Giger, Maryellen; Funaki, Brian S.; Zangan, Steven M. [University of Chicago Medical Center (United States)

    2015-06-15

    PurposeThe aim of this study was to investigate dual-lumen chest port infection rates in patients with head and neck cancer (HNC) compared to those with other malignancies (non-HNC).Materials and MethodsAn IRB-approved retrospective study was performed on 1,094 consecutive chest ports placed over a 2-year period. Patients with poor follow-up (n = 53), no oncologic history (n = 13), or single-lumen ports (n = 183) were excluded yielding a study population of 845 patients. The electronic medical records were queried for demographic information, data regarding ports and infections, and imaging review.ResultsHNC patients experienced more infections (42 vs. 30), an increased infection rate per 1,000 catheter days (0.68 vs. 0.21), and more early infections within 30 days compared to non-HNC patients (10 vs. 6) (p < 0.001, p < 0.001, p = 0.02, respectively). An existing tracheostomy at the time of port placement was associated with infection in the HNC group (p = 0.02) but was not an independent risk factor for infection in the study population overall (p = 0.06). There was a significant difference in age, male gender, and right-sided ports between the HNC and non-HNC groups (p < 0.01, p < 0.001, and p = 0.01), although these were not found to be independent risk factors for infection (p = 0.32, p = 0.76, p = 0.16).ConclusionHNC patients are at increased risk for infection of dual-lumen chest ports placed via a jugular approach compared to patients with other malignancies. Tracheostomy is associated with infection in HNC patients but is not an independent risk factor for infection in the oncologic population as a whole.

  16. Dual-Lumen Chest Port Infection Rates in Patients with Head and Neck Cancer

    International Nuclear Information System (INIS)

    Bos, Aaron; Ahmed, Osman; Jilani, Danial; Giger, Maryellen; Funaki, Brian S.; Zangan, Steven M.

    2015-01-01

    PurposeThe aim of this study was to investigate dual-lumen chest port infection rates in patients with head and neck cancer (HNC) compared to those with other malignancies (non-HNC).Materials and MethodsAn IRB-approved retrospective study was performed on 1,094 consecutive chest ports placed over a 2-year period. Patients with poor follow-up (n = 53), no oncologic history (n = 13), or single-lumen ports (n = 183) were excluded yielding a study population of 845 patients. The electronic medical records were queried for demographic information, data regarding ports and infections, and imaging review.ResultsHNC patients experienced more infections (42 vs. 30), an increased infection rate per 1,000 catheter days (0.68 vs. 0.21), and more early infections within 30 days compared to non-HNC patients (10 vs. 6) (p < 0.001, p < 0.001, p = 0.02, respectively). An existing tracheostomy at the time of port placement was associated with infection in the HNC group (p = 0.02) but was not an independent risk factor for infection in the study population overall (p = 0.06). There was a significant difference in age, male gender, and right-sided ports between the HNC and non-HNC groups (p < 0.01, p < 0.001, and p = 0.01), although these were not found to be independent risk factors for infection (p = 0.32, p = 0.76, p = 0.16).ConclusionHNC patients are at increased risk for infection of dual-lumen chest ports placed via a jugular approach compared to patients with other malignancies. Tracheostomy is associated with infection in HNC patients but is not an independent risk factor for infection in the oncologic population as a whole

  17. Intercostal drainage tube or intracardiac drainage tube?

    Directory of Open Access Journals (Sweden)

    N Anitha

    2016-01-01

    Full Text Available Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  18. Intercostal drainage tube or intracardiac drainage tube?

    Science.gov (United States)

    Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath

    2016-01-01

    Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  19. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos » NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  20. A simple coated-tube assay for alpha-foeto protein for clinical use

    International Nuclear Information System (INIS)

    Dakubu, S.; Ahene, I.S.; Foli, A.K.

    1977-01-01

    A standard method for coating plastic tubes with antiserum has been applied to coat tubes with rabbit antiserum to human alpha-foeto protein. The coated plastic tubes have been used to set up a radioimmunoassay system which is sensitive and convenient for use on the occasional clinical sample. For a successful coated-tube assay, it was found necessary to modify the final incubation mixture from what was suitable in a standard double antibody assay system. (orig.) [de

  1. High lumenal chloride in the lysosome is critical for lysosome function.

    Science.gov (United States)

    Chakraborty, Kasturi; Leung, KaHo; Krishnan, Yamuna

    2017-07-25

    Lysosomes are organelles responsible for the breakdown and recycling of cellular machinery. Dysfunctional lysosomes give rise to lysosomal storage disorders as well as common neurodegenerative diseases. Here, we use a DNA-based, fluorescent chloride reporter to measure lysosomal chloride in Caenorhabditis elegans as well as murine and human cell culture models of lysosomal diseases. We find that the lysosome is highly enriched in chloride, and that chloride reduction correlates directly with a loss in the degradative function of the lysosome. In nematodes and mammalian cell culture models of diverse lysosomal disorders, where previously only lysosomal pH dysregulation has been described, massive reduction of lumenal chloride is observed that is ~10 3 fold greater than the accompanying pH change. Reducing chloride within the lysosome impacts Ca 2+ release from the lysosome and impedes the activity of specific lysosomal enzymes indicating a broader role for chloride in lysosomal function.

  2. Further understanding of PbWO4 Scintillator characteristics and their optimisation. LUMEN activity in 1998

    CERN Document Server

    Baccaro, Stefania; Borgia, Bruno; Cecilia, Angelica; Dafinei, Ioan; Diemoz, Marcella; Fabeni, P; Festinesi, Armando; Longo, Egidio; Martini, M; Meinardi, F; Mihoková, E; Montecchi, Marco; Nikl, M; Pazzi, G P; Rosa, J; Sulc, Miroslav

    2000-01-01

    The aim of LUMEN collaboration was the investigation on single crystals of PbWO4 ( PWO): the results performed up to now provide the evidence of the possibility to optimise the optical properties of an intrinsic scintillator such as PWO. The control of essential requirements in the crystal preparation ( raw material purity, growing methods and post-growth annealing) as well as the introduction of selected dopants at suitable concentrations ( particularly trivalent and pentavalent ions) were found to be very successful in lowering the concentration of point defects in the lattice which strongly affect scintillation properties and radiation hardness. The systematic investigation effort to better understand the scintillation characteristics and to improve the quality of PWO crystals is due to their use for the CMS electromagnetic calorimeter.

  3. Quantitative coronary CT angiography: absolute lumen sizing rather than %stenosis predicts hemodynamically relevant stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Plank, Fabian [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Innsbruck Medical University, Department of Internal Medicine III - Cardiology, Innsbruck (Austria); Burghard, Philipp; Mayr, Agnes; Klauser, Andrea; Feuchtner, Gudrun [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Friedrich, Guy; Dichtl, Wolfgang [Innsbruck Medical University, Department of Internal Medicine III - Cardiology, Innsbruck (Austria); Wolf, Florian [Vienna Medical University, Department of Cardiovascular and Interventional Radiology, Vienna (Austria)

    2016-11-15

    To identify the most accurate quantitative coronary stenosis parameter by CTA for prediction of functional significant coronary stenosis resulting in coronary revascularization. 160 consecutive patients were prospectively examined with CTA. Proximal coronary stenosis was quantified by minimal lumen area (MLA) and minimal lumen diameter (MLD), %area and %diameter stenosis. Lesion length (LL) was measured. The reference standard was invasive coronary angiography (ICA) (>70 % stenosis, FFR <0.8). 210 coronary segments were included (59 % positive). MLA of ≤1.8 mm{sup 2} was identified as the optimal cut-off (c = 0.97, p < 0.001; 95 % CI 0.94-0.99) (sensitivity 90.9 %, specificity 89.3 %) for prediction of functional-relevant stenosis (for MLA >2.1 mm{sup 2} sensitivity was 100 %). The optimal cut-off for MLD was 1.2 mm (c = 0.92; p < 0.001; 95 % CI 0.88-95) (sensitivity 90.9, specificity 85.2) while %area and %diameter stenosis were less accurate (c = 0.89; 95 % CI 0.84-93, c = 0.87; 95 % CI 0.82-92, respectively, with thresholds at 73 % and 61 % stenosis). Accuracy for LL was c = 0.74 (95 % CI 0.67-81), and for LL/MLA and LL/MLD ratio c = 0.90 and c = 0.84. MLA ≤1.8 mm{sup 2} and MLD ≤1.2 mm are the most accurate cut-offs for prediction of haemodynamically significant stenosis by ICA, with a higher accuracy than relative % stenosis. (orig.)

  4. Analysis of the intestinal lumen microbiota in an animal model of colorectal cancer.

    Directory of Open Access Journals (Sweden)

    Qingchao Zhu

    Full Text Available Recent reports have suggested that multiple factors such as host genetics, environment and diet can promote the progression of healthy mucosa towards sporadic colorectal carcinoma. Accumulating evidence has additionally associated intestinal bacteria with disease initiation and progression. In order to examine and analyze the composition of gut microbiota in the absence of confounding influences, we have established an animal model of 1, 2-dimethylhydrazine (DMH-induced colon cancer. Using this model, we have performed pyrosequencing of the V3 region of the 16S rRNA genes in this study to determine the diversity and breadth of the intestinal microbial species. Our findings indicate that the microbial composition of the intestinal lumen differs significantly between control and tumor groups. The abundance of Firmicutes was elevated whereas the abundance of Bacteroidetes and Spirochetes was reduced in the lumen of CRC rats. Fusobacteria was not detected in any of the healthy rats and there was no significant difference in observed Proteobacteria species when comparing the bacterial communities between our two groups. Interestingly, the abundance of Proteobacteria was higher in CRC rats. At the genus level, Bacteroides exhibited a relatively higher abundance in CRC rats compared to controls (14.92% vs. 9.22%, p<0.001. Meanwhile, Prevotella (55.22% vs. 26.19%, Lactobacillus (3.71% vs. 2.32% and Treponema (3.04% vs. 2.43%, were found to be significantly more abundant in healthy rats than CRC rats (p<0.001, respectively. We also demonstrate a significant reduction of butyrate-producing bacteria such as Roseburia and Eubacterium in the gut microbiota of CRC rats. Furthermore, a significant increase in Desulfovibrio, Erysipelotrichaceae and Fusobacterium was also observed in the tumor group. A decrease in probiotic species such as Ruminococcus and Lactobacillus was likewise observed in the tumor group. Collectively, we can conclude that a significant

  5. A nonimaging catheter for measurement of coronary artery lumen area: a first in man pilot study.

    Science.gov (United States)

    Hermiller, James; Choy, Jenny S; Svendsen, Mark; Bigelow, Brian; Fouts, Andrew M; Hall, Jack; Parr, Kirk; Ball, Michael; Sinha, Anjan; Bhatt, Deepak L; Kassab, Ghassan S

    2011-08-01

    The objective of this human pilot study was to determine the safety and the level of agreement between a novel nonimaging 2.7 Fr. catheter-based system (LumenRECON, LR) that uses electrical conductance for measurement of lumen cross-sectional area (CSA) with intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA). Based on previous animal studies, we hypothesized the level of agreement between LR and IVUS to be 13%. Accurate and reproducible vessel sizing is essential for optimal percutaneous coronary intervention (PCI). A total of 12 patients were studied to evaluate the safety, accuracy, and reproducibility of the system in comparison with IVUS and QCA. The CSA of coronary arteries was determined by IVUS, QCA, and LR in the distal, proximal, and center of a lesion during standard PCI. A Bland-Altman plot of the LR versus IVUS and QCA show a nonsignificant mean difference between the two measurements of 0.04 and 0.07 mm in diameter, respectively. The root mean square error of LR versus IVUS and QCA was 14.3 and 25.8% of the mean IVUS or QCA diameter, respectively. The mean of the difference between two LR duplicate measurements was nearly zero (0.03 mm) and the repeatability coefficient was within 8.7% of the mean of the two measurements. There were no procedural complications nor were any device-related MACE reported within 30 days of the procedure. This proof of concept pilot study establishes the safety and accuracy of the conductance technology for a pivotal trial of coronary sizing. Copyright © 2011 Wiley-Liss, Inc.

  6. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  7. Double Trouble

    NARCIS (Netherlands)

    Elsaesser, Thomas; Kievit, Robert; Simons, Jan

    1994-01-01

    Double Trouble highlights the career of Dutch scriptwriter and television producer Chiem van Houweninge, well-known for his long-running TV comedy series and as author of episodes for TV detective series. Double Trouble gives Van Houweninge's own views on writing and filming in television prime

  8. Elephant trunk in a small-calibre true lumen for chronic aortic dissection: cause of haemolytic anaemia?

    Science.gov (United States)

    Araki, Haruna; Kitamura, Tadashi; Horai, Tetsuya; Shibata, Ko; Miyaji, Kagami

    2014-12-01

    The elephant trunk technique for aortic dissection is useful for reducing false lumen pressure; however, a folded vascular prosthesis inside the aorta can cause haemolysis. The purpose of this study was to investigate whether an elephant trunk in a small-calibre lumen can cause haemolysis. Inpatient and outpatient records were retrospectively reviewed. Two cases of haemolytic anaemia after aortic surgery using the elephant trunk technique were identified from 2011 to 2013. A 64-year-old man, who underwent graft replacement of the ascending aorta for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta and moderate aortic regurgitation. A two-stage surgery was scheduled. Total arch replacement with an elephant trunk in the true lumen and concomitant aortic valve replacement were performed. Postoperatively, he developed severe haemolytic anaemia because of the folded elephant trunk. The anaemia improved after the second surgery, including graft replacement of the descending aorta. Similarly, a 61-year-old man, who underwent total arch replacement for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta. Graft replacement of the descending aorta with an elephant trunk inserted into the true lumen was performed. The patient postoperatively developed haemolytic anaemia because of the folded elephant trunk, which improved after additional stent grafting into the elephant trunk. A folded elephant trunk in a small-calibre lumen can cause haemolysis. Therefore, inserting an elephant trunk in a small-calibre true lumen during surgery for chronic aortic dissection should be avoided. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Concentration polarization effects on the macromolecular transport in the presence of non-uniform magnetic field: A numerical study using a lumen-wall model

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadpourfard, M., E-mail: Mohammadpour@azaruniv.edu [Department of Mechanical Engineering, Azarbaijan Shahid Madani University, Tabriz 53751-71379 (Iran, Islamic Republic of); Aminfar, H., E-mail: hh_aminfar@tabrizu.ac.ir [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of); Khajeh, K., E-mail: khajeh.k.2005@gmail.com [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2014-04-01

    In this paper, the concentration polarization phenomena in a two dimensional tube under steady state conditions containing ferrofluid (blood and 4 vol% Fe{sub 3}O{sub 4}) is reported in the presence of non-uniform magnetic field. Lumen-wall model has been used for solving the mass transport equation. Hemodynamics parameters such as flow rate, viscosity, wall shear stress (WSS) and the macromolecules surface concentration which accumulate on the blood vessel wall, influenced the formation and progression of atherosclerosis disease. Effective parameters on the low density lipoprotein (LDL) surface concentration (LSC) such as: the wall filtration velocity, inlet Reynolds number and WSS under applied non-uniform magnetic field have been examined. Numerical solution of governing equations of the flow field have been obtained by using the single-phase model and the control volume technique. Magnetic field is generated by an electric current going through a thin and straight wire oriented perpendicular to the tube. Results show WSS in the vicinity of magnetic field source increased and LSC decreased along the wall. - Highlights: • In this paper the concentration polarization phenomena of blood flow is reported in the presence of non-uniform magnetic field. • In presence of non-uniform magnetic field LSC will decrease along the wall due to the increasing the velocity gradients near the magnetic source. • When non-uniform magnetic field intensity increases, LSC along the wall becomes lower. • Non-uniform magnetic field can affects the flow more in low Reynolds numbers.

  10. Indication chamber of liquid metal fired steam generators with double wall for heat transfer

    International Nuclear Information System (INIS)

    Matal, O.; Martoch, J.

    1982-01-01

    The double wall of the steam generator consists of inner and outer tubes anchored in a tube plate. Between the tubes are indication spaces which end in recesses formed at least in one of the tube plates and coaxial with the outer tubes. The recesses interconnected with channels form the indication chamber to which is connected at least one sensor of the alarm signal equipment. (B.S.)

  11. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections

    DEFF Research Database (Denmark)

    Walter, Daisy; Will, Uwe; Sanchez-Yague, Andres

    2015-01-01

    BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the effi......BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate...

  12. Lunar Lava Tube Sensing

    Science.gov (United States)

    York, Cheryl Lynn; Walden, Bryce; Billings, Thomas L.; Reeder, P. Douglas

    1992-01-01

    Large (greater than 300 m diameter) lava tube caverns appear to exist on the Moon and could provide substantial safety and cost benefits for lunar bases. Over 40 m of basalt and regolith constitute the lava tube roof and would protect both construction and operations. Constant temperatures of -20 C reduce thermal stress on structures and machines. Base designs need not incorporate heavy shielding, so lightweight materials can be used and construction can be expedited. Identification and characterization of lava tube caverns can be incorporated into current precursor lunar mission plans. Some searches can even be done from Earth. Specific recommendations for lunar lava tube search and exploration are (1) an Earth-based radar interferometer, (2) an Earth-penetrating radar (EPR) orbiter, (3) kinetic penetrators for lunar lava tube confirmation, (4) a 'Moon Bat' hovering rocket vehicle, and (5) the use of other proposed landers and orbiters to help find lunar lava tubes.

  13. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube......’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  14. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  15. Rectangular drift tube characteristics

    International Nuclear Information System (INIS)

    Denisov, D.S.; Musienko, Yu.V.

    1985-01-01

    Results on the study of the characteristics of a 50 x 100 mm aluminium drift tube are presented. The tube was filled with argon-methane and argon-isobutane mixtures. With 16 per cent methane concentration the largest deviation from a linear relation between the drift time and the drift path over 50 mm is less than 2 mm. The tube filled with argon-isobutane mixture is capable of operating in a limited streamer mode

  16. Categorising YouTube

    OpenAIRE

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a...

  17. Pressure tube reactor

    International Nuclear Information System (INIS)

    Susuki, Akira; Murata, Shigeto; Minato, Akihiko.

    1993-01-01

    In a pressure tube reactor, a reactor core is constituted by arranging more than two units of a minimum unit combination of a moderator sealing pipe containing a calandria tube having moderators there between and a calandria tube and moderators. The upper header and a lower header of the calandria tank containing moderators are communicated by way of the moderator sealing tube. Further, a gravitationally dropping mechanism is disposed for injecting neutron absorbing liquid to a calandria gas injection portion. A ratio between a moderator volume and a fuel volume is defined as a function of the inner diameter of the moderator sealing tube, the outer diameter of the calandria tube and the diameter of fuel pellets, and has no influence to intervals of a pressure tube lattice. The interval of the pressure tube lattice is enlarged without increasing the size of the pressure tube, to improve production efficiency of the reactor and set a coolant void coefficient more negative, thereby enabling to improve self controllability and safety. Further, the reactor scram can be conducted by injecting neutron absorbing liquid. (N.H.)

  18. Heated Tube Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Heated Tube Facility at NASA GRC investigates cooling issues by simulating conditions characteristic of rocket engine thrust chambers and high speed airbreathing...

  19. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1984-10-01

    A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization

  20. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Tapping, R.L.; Stipan, L.

    1992-03-01

    A survey of steam generator operating experience for 1986 has been carried out for 184 pressurized water and pressurized heavy-water reactors, and 1 water-cooled, graphite-moderated reactor. Tubes were plugged at 75 of the reactors (40.5%). In 1986, 3737 tubes were plugged (0.14% of those in service) and 3148 tubes were repaired by sleeving. A small number of reactors accounted for the bulk of the plugged tubes, a phenomenon consistent with previous years. For 1986, the available tubesheet sludge data for 38 reactors has been compiled into tabular form, and sludge/deposit data will be incorporated into all future surveys

  1. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  2. Mechanism of lumen gain with a novel rotational aspiration atherectomy system for peripheral arterial disease: examination by intravascular ultrasound.

    Science.gov (United States)

    Hassan, Ali H M; Ako, Junya; Waseda, Katsuhisa; Honda, Yasuhiro; Zeller, Thomas; Leon, Martin B; Fitzgerald, Peter J

    2010-01-01

    The purpose of this study was to evaluate the mechanism of luminal gain with a novel atheroablation system (Pathway PV) for the treatment of peripheral artery disease using intravascular ultrasound (IVUS). The atherectomy system is a rotational atherectomy device, which employs expandable rotating blades with ports that allow flushing and aspiration of the plaque material or thrombus. In this first-in-man clinical study, IVUS analysis was available in 6 patients with lower limb ischemia treated with this device. The treatment results were assessed using IVUS at pre and post atherectomy. Lumen beyond burr size (LBB) was defined as lumen gain divided by the estimated burr area determined by the burr-size. IVUS analysis was available in six patients (superficial femoral artery n=3, popliteal artery n=2, posterior tibial artery n=1). Atheroablation achieved a significant increase in lumen area (LA) (preintervention 3.9+/-0.4, postatheroablation 8.0+/-1.7 mm(2), Patherectomy device achieved significant luminal gain by debulking in the absence of vessel stretching. The LA was greater than burr-sized lumen expectancy at cross-sections along the treated segments, suggesting a complimentary role of aspiration in luminal gain in atherosclerotic peripheral artery lesions.

  3. Low Iodine in the Follicular Lumen Caused by Cytoplasm Mis-localization of Sodium Iodide Symporter may Induce Nodular Goiter.

    Science.gov (United States)

    Huang, Huibin; Shi, Yaxiong; Liang, Bo; Cai, Huiyao; Cai, Qingyan

    2017-10-01

    Iodine is a key ingredient in the synthesis of thyroid hormones and also a major factor in the regulation of thyroid function. A local reduction of iodine content in follicular lumen leads to overexpression of local thyroid-stimulating hormone receptor (TSHr), which in turn excessively stimulates the regional thyroid tissue, and result in the formation of nodular goiter. In this study, we investigated the relationship between iodine content and sodium iodide symporter (NIS) expression by using the clinical specimens from patients with nodular goiter and explored the pathogenesis triggered by iodine deficiency in nodular goiter. In total, 28 patients were clinically histopathologically confirmed to have nodular goiter and the corresponding adjacent normal thyroid specimens were harvested simultaneously. Western blot and immunohistochemistry were performed to assay NIS expression and localization in thyrocytes of both nodular goiter and adjacent normal thyroid tissues. NIS expression mediated by iodine in follicular lumen was confirmed by follicular model in vitro. Meanwhile, radioscan with iodine-131were conducted on both nodular goiter and adjacent normal thyroid. Our data showed that NIS expression in nodular goiter was significantly higher than that in adjacent normal tissues, which was associated with low iodine in the follicular lumen. Abnormal localization of NIS and lower amount of radioactive iodine-131 were also found in nodular goiter. Our data implied that low iodine in the follicular lumen caused by cytoplasm mis-localization of NIS may induce nodular goiter.

  4. Method for shaping polyethylene tubing

    Science.gov (United States)

    Kramer, R. C.

    1981-01-01

    Method forms polyethylene plastic tubing into configurations previously only possible with metal tubing. By using polyethylene in place of copper or stain less steel tubing inlow pressure systems, fabrication costs are significantly reduced. Polyethylene tubing can be used whenever low pressure tubing is needed in oil operations, aircraft and space applications, powerplants, and testing laboratories.

  5. Pyrotechnic Tubing Connector

    Science.gov (United States)

    Graves, Thomas J.; Yang, Robert A.

    1988-01-01

    Tool forms mechanical seal at joint without levers or hydraulic apparatus. Proposed tool intended for use in outer space used on Earth by heavily garbed workers to join tubing in difficult environments. Called Pyrotool, used with Lokring (or equivalent) fittings. Piston slides in cylinder when pushed by gas from detonating pyrotechnic charge. Impulse of piston compresses fittings, sealing around butting ends of tubes.

  6. Molybdenum Tube Characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Beaux II, Miles Frank [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Usov, Igor Olegovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-07

    Chemical vapor deposition (CVD) techniques have been utilized to produce free-standing molybdenum tubes with the end goal of nuclear fuel clad applications. In order to produce tubes with properties desirable for this application, deposition rates were lowered requiring long deposition durations on the order of 50 hours. Standard CVD methods as well as fluidized-bed CVD (FBCVD) methods were applied towards these objectives. Characterization of the tubes produced in this manner revealed material suitable for fuel clad applications, but lacking necessary uniformity across the length of the tubes. The production of freestanding Mo tubes that possess the desired properties across their entire length represents an engineering challenge that can be overcome in a next iteration of the deposition system.

  7. Dark-lumen magnetic resonance colonography in patients with suspected sigmoid diverticulitis: a feasibility study

    International Nuclear Information System (INIS)

    Ajaj, Waleed; Lauenstein, Thomas; Goehde, Susanne; Kuehle, Christiane; Herborn, Christoph U.; Ruehm, Stefan G.; Langhorst, Jost; Zoepf, Thomas; Gerken, Guido; Goyen, Mathias

    2005-01-01

    To assess dark-lumen magnetic resonance colonography (MRC) for the evaluation of patients with suspected sigmoid diverticulitis. Forty patients with suspected sigmoid diverticulitis underwent MRC within 72 h prior to conventional colonoscopy (CC). A three-dimensional T1-weighted volumetric interpolated breath-hold examination sequence was acquired after an aqueous enema and intravenous administration of gadolinium-based contrast agents. All MRC data were evaluated by two radiologists. Based on wall thickness and focal uptake of contrast material and pericolic reaction including mesenteric infiltration on T1-weighted sequence the sigmoid colon was assessed for the presence of diverticulitis. MRC classified 17 of the 40 patients as normal with regard to sigmoid diverticulitis. However, CC confirmed the presence of light inflammatory signs in four patients which were missed in MRC. MRC correctly identified wall thickness and contrast uptake of the sigmoid colon in the other 23 patients. In three of these patients false-positive findings were observed, and MRC classified the inflammation of the sigmoid colon as diverticulitis whereas CC and histopathology confirmed invasive carcinoma. MRC detected additionally relevant pathologies of the entire colon and could be performed in cases where CC was incomplete. MRC may be considered a promising alternative to CC for the detection of sigmoid diverticulitis. (orig.)

  8. Lumen apposing metal stents for pancreatic fluid collections: Recognition and management of complications.

    Science.gov (United States)

    DeSimone, Michael L; Asombang, Akwi W; Berzin, Tyler M

    2017-09-16

    For patients recovering from acute pancreatitis, the development of a pancreatic fluid collection (PFC) predicts a more complex course of recovery, and introduces difficult management decisions with regard to when, whether, and how the collection should be drained. Most PFCs resolve spontaneously and drainage is indicated only in pseudocysts and walled-off pancreatic necrosis when the collections are causing symptoms and/or local complications such as biliary obstruction. Historical approaches to PFC drainage have included surgical (open or laparoscopic cystgastrostomy or pancreatic debridement), and the placement of percutaneous drains. Endoscopic drainage techniques have emerged in the last several years as the preferred approach for most patients, when local expertise is available. Lumen-apposing metal stents (LAMS) have recently been developed as a tool to facilitate potentially safer and easier endoscopic drainage of pancreatic fluid collections, and less commonly, for other indications, such as gallbladder drainage. Physicians considering LAMS placement must be aware of the complications most commonly associated with LAMS including bleeding, migration, buried stent, stent occlusion, and perforation. Because of the patient complexity associated with severe pancreatitis, management of pancreatic fluid collections can be a complex and multidisciplinary endeavor. Successful and safe use of LAMS for patients with pancreatic fluid collections requires that the endoscopist have a full understanding of the potential complications of LAMS techniques, including how to recognize and manage expected complications.

  9. Rap1 integrates tissue polarity, lumen formation, and tumorigenicpotential in human breast epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Masahiko; Nelson, Celeste M.; Myers, Connie A.; Bissell,Mina J.

    2006-09-29

    Maintenance of apico-basal polarity in normal breast epithelial acini requires a balance between cell proliferation, cell death, and proper cell-cell and cell-extracellular matrix signaling. Aberrations in any of these processes can disrupt tissue architecture and initiate tumor formation. Here we show that the small GTPase Rap1 is a crucial element in organizing acinar structure and inducing lumen formation. Rap1 activity in malignant HMT-3522 T4-2 cells is appreciably higher than in S1 cells, their non-malignant counterparts. Expression of dominant-negative Rap1 resulted in phenotypic reversion of T4-2 cells, led to formation of acinar structures with correct apico-basal polarity, and dramatically reduced tumor incidence despite the persistence of genomic abnormalities. The resulting acini contained prominent central lumina not observed when other reverting agents were used. Conversely, expression of dominant-active Rap1 in T4-2 cells inhibited phenotypic reversion and led to increased invasiveness and tumorigenicity. Thus, Rap1 acts as a central regulator of breast architecture, with normal levels of activation instructing apical polarity during acinar morphogenesis, and increased activation inducing tumor formation and progression to malignancy.

  10. Epithelial organization and cyst lumen expansion require efficient Sec13–Sec31-driven secretion

    Science.gov (United States)

    Townley, Anna K.; Schmidt, Katy; Hodgson, Lorna; Stephens, David J.

    2012-01-01

    Epithelial morphogenesis is directed by interactions with the underlying extracellular matrix. Secretion of collagen and other matrix components requires efficient coat complex II (COPII) vesicle formation at the endoplasmic reticulum. Here, we show that suppression of the outer layer COPII component, Sec13, in zebrafish embryos results in a disorganized gut epithelium. In human intestinal epithelial cells (Caco-2), Sec13 depletion causes defective epithelial polarity and organization on permeable supports. Defects are seen in the ability of cells to adhere to the substrate, form a monolayer and form intercellular junctions. When embedded in a three-dimensional matrix, Sec13-depleted Caco-2 cells form cysts but, unlike controls, are defective in lumen expansion. Incorporation of primary fibroblasts within the three-dimensional culture substantially restores normal morphogenesis. We conclude that efficient COPII-dependent secretion, notably assembly of Sec13–Sec31, is required to drive epithelial morphogenesis in both two- and three-dimensional cultures in vitro, as well as in vivo. Our results provide insight into the role of COPII in epithelial morphogenesis and have implications for the interpretation of epithelial polarity and organization assays in cell culture. PMID:22331354

  11. Epithelial organization and cyst lumen expansion require efficient Sec13-Sec31-driven secretion.

    Science.gov (United States)

    Townley, Anna K; Schmidt, Katy; Hodgson, Lorna; Stephens, David J

    2012-02-01

    Epithelial morphogenesis is directed by interactions with the underlying extracellular matrix. Secretion of collagen and other matrix components requires efficient coat complex II (COPII) vesicle formation at the endoplasmic reticulum. Here, we show that suppression of the outer layer COPII component, Sec13, in zebrafish embryos results in a disorganized gut epithelium. In human intestinal epithelial cells (Caco-2), Sec13 depletion causes defective epithelial polarity and organization on permeable supports. Defects are seen in the ability of cells to adhere to the substrate, form a monolayer and form intercellular junctions. When embedded in a three-dimensional matrix, Sec13-depleted Caco-2 cells form cysts but, unlike controls, are defective in lumen expansion. Incorporation of primary fibroblasts within the three-dimensional culture substantially restores normal morphogenesis. We conclude that efficient COPII-dependent secretion, notably assembly of Sec13-Sec31, is required to drive epithelial morphogenesis in both two- and three-dimensional cultures in vitro, as well as in vivo. Our results provide insight into the role of COPII in epithelial morphogenesis and have implications for the interpretation of epithelial polarity and organization assays in cell culture.

  12. Delivery of CSF-1R to the lumen of macropinosomes promotes its destruction in macrophages

    Science.gov (United States)

    Lou, Jieqiong; Low-Nam, Shalini T.; Kerkvliet, Jason G.; Hoppe, Adam D.

    2014-01-01

    ABSTRACT Activation of the macrophage colony stimulating factor-1 receptor (CSF-1R) by CSF-1 stimulates pronounced macropinocytosis and drives proliferation of macrophages. Although the role of macropinocytosis in CSF-1R signaling remains unknown, we show here that, despite internalizing large quantities of plasma membrane, macropinosomes contribute little to the internalization of the CSF-1–CSF-1R complex. Rather, internalization of the CSF-1R in small endocytic vesicles that are sensitive to clathrin disruption, outcompetes macropinosomes for CSF-1R endocytosis. Following internalization, small vesicles carrying the CSF-1R underwent homotypic fusion and then trafficked to newly formed macropinosomes bearing Rab5. As these macropinosomes matured, acquiring Rab7, the CSF-1R was transported into their lumen and degraded. Inhibition of macropinocytosis delayed receptor degradation despite no disruption to CSF-1R endocytosis. These data indicate that CSF-1-stimulated macropinosomes are sites of multivesicular body formation and accelerate CSF-1R degradation. Furthermore, we demonstrate that macropinocytosis and cell growth have a matching dose dependence on CSF-1, suggesting that macropinosomes might be a central mechanism coupling CSF-1R signaling and macrophage growth. PMID:25335894

  13. Evaluation of esophageal motility utilizing the functional lumen imaging probe (FLIP)

    Science.gov (United States)

    Carlson, Dustin A.; Kahrilas, Peter J.; Lin, Zhiyue; Hirano, Ikuo; Gonsalves, Nirmala; Listernick, Zoe; Ritter, Katherine; Tye, Michael; Ponds, Fraukje A.; Wong, Ian; Pandolfino, John E.

    2016-01-01

    Background Esophagogastric junction (EGJ) distensibility and distension-mediated peristalsis can be assessed with the functional lumen imaging probe (FLIP) during a sedated upper endoscopy. We aimed to describe esophageal motility assessment using FLIP topography in patients presenting with dysphagia. Methods 145 patients (ages 18 – 85, 54% female) with dysphagia that completed upper endoscopy with a 16-cm FLIP assembly and high-resolution manometry (HRM) were included. HRM was analyzed according to the Chicago Classification of esophageal motility disorders; major esophageal motility disorders were considered ‘abnormal’. FLIP studies were analyzed using a customized program to calculate the EGJ-distensibility index (DI) and generate FLIP topography plots to identify esophageal contractility patterns. FLIP topography was considered ‘abnormal’ if EGJ-DI was esophageal motility and 29 normal motility. 17 (50%) had abnormal FLIP topography including 13 (37%) with abnormal EGJ-DI. Conclusions FLIP topography provides a well-tolerated method for esophageal motility assessment (especially to identify achalasia) at the time of upper endoscopy. FLIP topography findings that are discordant with HRM may indicate otherwise undetected abnormalities of esophageal function, thus FLIP provides an alternative and complementary method to HRM for evaluation of non-obstructive dysphagia. PMID:27725650

  14. Improving lumen maintenance by nanopore array dispersed quantum dots for on-chip light emitting diodes

    Science.gov (United States)

    Chen, Quan; Yang, Fan; Wan, Renzhuo; Fang, Dong

    2017-12-01

    The temperature stability of quantum dots (QDs), which is crucial for integrating into high power light-emitting diodes (LEDs) in the on-chip configuration, needs to be further improved. In this letter, we report warm white LEDs, where CdSe/ZnS nanoparticles were incorporated into a porous anodic alumina (PAA) matrix with a chain structure by the self-assembly method. Experiments demonstrate that the QD concentration range in toluene solvent from 1% mg/μl to 1.2% mg/μl in combination with the PAA matrix shows the best luminous property. To verify the reliability of the as-prepared device, a comparison experiment was conducted. It indicates excellent lumen maintenance of the light source and less chromaticity coordinate shift under accelerated life testing conditions. Experiments also prove that optical depreciation was only up to 4.6% of its initial value after the 1500 h aging test at the junction temperature of 76 °C.

  15. Numerical Investigation of Characteristic of Anisotropic Thermal Conductivity of Natural Fiber Bundle with Numbered Lumens

    Directory of Open Access Journals (Sweden)

    Guan-Yu Zheng

    2014-01-01

    Full Text Available Natural fiber bundle like hemp fiber bundle usually includes many small lumens embedded in solid region; thus, it can present lower thermal conduction than that of conventional fibers. In the paper, characteristic of anisotropic transverse thermal conductivity of unidirectional natural hemp fiber bundle was numerically studied to determine the dependence of overall thermal property of the fiber bundle on that of the solid region phase. In order to efficiently predict its thermal property, the fiber bundle was embedded into an imaginary matrix to form a unit composite cell consisting of the matrix and the fiber bundle. Equally, another unit composite cell including an equivalent solid fiber was established to present the homogenization of the fiber bundle. Next, finite element thermal analysis implemented by ABAQUS was conducted in the two established composite cells by applying proper thermal boundary conditions along the boundary of unit cell, and influences of the solid region phase and the equivalent solid fiber on the composites were investigated, respectively. Subsequently, an optional relationship of thermal conductivities of the natural fiber bundle and the solid region was obtained by curve fitting technique. Finally, numerical results from the obtained fitted curves were compared with the analytic Hasselman-Johnson’s results and others to verify the present numerical model.

  16. High lumenal chloride in the lysosome is critical for lysosome function

    Science.gov (United States)

    Chakraborty, Kasturi; Leung, KaHo; Krishnan, Yamuna

    2017-01-01

    Lysosomes are organelles responsible for the breakdown and recycling of cellular machinery. Dysfunctional lysosomes give rise to lysosomal storage disorders as well as common neurodegenerative diseases. Here, we use a DNA-based, fluorescent chloride reporter to measure lysosomal chloride in Caenorhabditis elegans as well as murine and human cell culture models of lysosomal diseases. We find that the lysosome is highly enriched in chloride, and that chloride reduction correlates directly with a loss in the degradative function of the lysosome. In nematodes and mammalian cell culture models of diverse lysosomal disorders, where previously only lysosomal pH dysregulation has been described, massive reduction of lumenal chloride is observed that is ~103 fold greater than the accompanying pH change. Reducing chloride within the lysosome impacts Ca2+ release from the lysosome and impedes the activity of specific lysosomal enzymes indicating a broader role for chloride in lysosomal function. DOI: http://dx.doi.org/10.7554/eLife.28862.001 PMID:28742019

  17. Building lab-scale x-ray tube based irradiators

    International Nuclear Information System (INIS)

    Haff, Ron; Jackson, Eric; Gomez, Joseph; Light, Doug; Follett, Peter; Simmons, Greg; Higbee, Brad

    2016-01-01

    Here we report the use of x-ray tube based irradiators as alternatives to gamma sources for laboratory scale irradiation. Irradiators were designed with sample placement in closest possible proximity to the source, allowing high dose rates for small samples. Designs using 1000 W x-ray tubes in single tube, double tube, and four tube configurations are described, as well as various cabinet construction techniques. Relatively high dose rates were achieved for small samples, demonstrating feasibility for laboratory based irradiators for research purposes. Dose rates of 9.76, 5.45, and 1.7 Gy/min/tube were measured at the center of a 12.7 cm container of instant rice at 100 keV, 70 keV, and 40 keV, respectively. Dose uniformity varies dramatically as the distance from source to container. For 2.54 cm diameter sample containers containing adult Navel Orangeworm, dose rates of 50–60 Gy/min were measured in the four tube system. - Highlights: • X-ray is demonstrated as an alternative to gamma for lab-based irradiation. • Cabinets using one, two, and four 1000 W tubes are reported. • Dose rate of 9.8 Gy/min/tube at the center of a 12.7 cm container of instant rice. • Dose uniformity varies dramatically as the distance from source to container.

  18. Cell Wall Composition, Biosynthesis and Remodeling during Pollen Tube Growth

    Directory of Open Access Journals (Sweden)

    Jean-Claude Mollet

    2013-03-01

    Full Text Available The pollen tube is a fast tip-growing cell carrying the two sperm cells to the ovule allowing the double fertilization process and seed setting. To succeed in this process, the spatial and temporal controls of pollen tube growth within the female organ are critical. It requires a massive cell wall deposition to promote fast pollen tube elongation and a tight control of the cell wall remodeling to modify the mechanical properties. In addition, during its journey, the pollen tube interacts with the pistil, which plays key roles in pollen tube nutrition, guidance and in the rejection of the self-incompatible pollen. This review focuses on our current knowledge in the biochemistry and localization of the main cell wall polymers including pectin, hemicellulose, cellulose and callose from several pollen tube species. Moreover, based on transcriptomic data and functional genomic studies, the possible enzymes involved in the cell wall remodeling during pollen tube growth and their impact on the cell wall mechanics are also described. Finally, mutant analyses have permitted to gain insight in the function of several genes involved in the pollen tube cell wall biosynthesis and their roles in pollen tube growth are further discussed.

  19. Status of pulse tube development at CEA/SBT

    International Nuclear Information System (INIS)

    Ravex, A.; Rolland, P.

    1994-01-01

    Interest in the pulse tube comes from its potential for high reliability and low level of induced vibration. A numerical model has been developed to provide a tool for practical design. It has been successfully validated against the experimental results obtained with a single stage double inlet pulse tube which has achieved a temperature of 28 K at a frequency of a few Hz. Further developments have demonstrated the capability of operating a pulse tube at higher frequencies in association with a Stirling pressure oscillator. Current projects include coaxial geometry for miniature pulse tubes with linear resonant pressure oscillators. A 4 K multistaged pulse tube is also in development. (authors). 5 figs., 12 refs

  20. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  1. Strengthening of a railway bridge with NSMR and CFRP tubes

    DEFF Research Database (Denmark)

    Täljsten, Björn; Bennitz, Anders; Danielsson, Georg

    2008-01-01

    Strengthening of structures with CFRP is today considered an accepted method to upgrade concrete structures. In this paper two different CFRP strengthening systems are combined to give extended service life to a Swedish double-trough-double-track railway bridge, constructed in concrete with a 10 ....... Sensors on bars and tubes display proofs of utilization of the CFRP while displacement sensors and strain gauges on the steel reinforcement due to the small loads in the service limit state show minor effect....

  2. Crush analysis of the foam-filled bitubal circular tube under oblique impact

    Science.gov (United States)

    Djamaluddin, F.; Abdullah, S.; Arrifin, A. K.; Nopiah, Z. M.

    2018-02-01

    This paper presents crashworthiness analysis of bitubal cylindrical tubes under different impact angular. The numerical solution of double cylindrical tubes are determined by finite element analysis (FEA). Moreover, the structure was impacted by mass block as impactor respect to longitudinal direction of the tubes. The model of structure was developed by non-linear ABAQUS sofware with variations of load angle and dimensions of tube. The outcome of this study is the respons parameters such as the peak crusing force (PCF), energy absorption (EA) and specific energy absorption (SEA), thus it can be expected this tube as the great energy absorber.

  3. Longitudinally excited CO2 laser with multiple laser tubes

    Science.gov (United States)

    Uno, Kazuyuki; Akitsu, Tetsuya; Jitsuno, Takahisa

    2016-11-01

    We developed a longitudinally excited CO2 laser system that was constituted of two or three laser tubes and a single driving circuit. The multiple laser tubes simultaneously produced almost the same short laser pulses with a spike pulse width of about 164 ns and a pulse tail length of about 74 μs with a single driving circuit. The double-tube system was constituted of two 30 cm-long laser tubes with inner diameters of 13 mm and 16 mm and a single driving circuit with an input energy of 2.18 J. The output energy of the 13 mm-tube was 23.3 mJ, and that of the 16 mm-tube was 21.9 mJ at a gas pressure of 4.2 kPa (CO2:N2:He = 1:1:2). The triple-tube system was constituted of three 30 cm-long laser tubes with inner diameters of 9 mm, 13 mm, and 16 mm and a single driving circuit with an input energy of 2.18 J. The output energy of the 9 mm tube was 15.9 mJ, that of the 13 mm tube was 24.1 mJ, and that of the 16 mm tube was 19.2 mJ at a gas pressure of 4.2 kPa. With the same driving circuit and the same input energy, the total output energies of the multitube laser systems were higher than the output energy of a single-tube system.

  4. Helically coiled tube heat exchanger

    International Nuclear Information System (INIS)

    Harris, A.M.

    1981-01-01

    In a heat exchanger such as a steam generator for a nuclear reactor, two or more bundles of helically coiled tubes are arranged in series with the tubes in each bundle integrally continuing through the tube bundles arranged in series therewith. Pitch values for the tubing in any pair of tube bundles, taken transverse to the path of the reactor coolant flow about the tubes, are selected as a ratio of two unequal integers to permit efficient operation of each tube bundle while maintaining the various tube bundles of the heat exchanger within a compact envelope. Preferably, the helix angle and tube pitch parallel to the path of coolant flow are constant for all tubes in a single bundle so that the tubes are of approximately the same length within each bundle

  5. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1982-04-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1980. Tube defects occurred at 38% of the 97 reactors surveyed. This is a marginal improvement over 1979 when defects occurred at 41% of the reactors. The number of failed tubes was also lower, 0.14% of the tubes in service in 1980 compared with 0.20% of those in service in 1979. Analysis of the causes of these failures indicates that stress corrosion cracking was the leading failure mechanism. Reactors that used all-volatile treatment of secondary water, with or without full-flow condensate demineralization since start-up showed the lowest incidence of corrosion-related defects

  6. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  7. Fuel assembly guide tube

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    This invention is directed toward a nuclear fuel assembly guide tube arrangement which restrains spacer grid movement due to coolant flow and which offers secondary means for supporting a fuel assembly during handling and transfer operations

  8. Bull Moose Tube Company

    Science.gov (United States)

    The EPA is providing notice of a proposed Administrative Penalty Assessment against the Bull Moose Tube Company, a business located at 1819 Clarkson Road, Chesterfield, MO, 63017, for alleged violations at the facility located at 406 East Industrial Drive,

  9. Tracheostomy tube - eating

    Science.gov (United States)

    Trach - eating ... take your first bites. Certain factors may make eating or swallowing harder, such as: Changes in the ... easier to swallow. Suction the tracheostomy tube before eating. This will keep you from coughing while eating, ...

  10. Three Cell Fusions during Double Fertilization.

    Science.gov (United States)

    Sprunck, Stefanie; Dresselhaus, Thomas

    2015-05-07

    Fertilization of both egg and central cell is a major distinguishing feature of flowering plants. Now, Maruyama et al. report a third cell fusion event between the persistent synergid and the fertilized central cell shortly after double fertilization in Arabidopsis. This causes rapid dilution of pollen tube attractant(s), preventing polytubey. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  12. The Functional Lumen Imaging Probe Detects Esophageal Contractility not Observed with Manometry in Patients with Achalasia

    Science.gov (United States)

    Carlson, Dustin A.; Lin, Zhiyue; Kahrilas, Peter J.; Sternbach, Joel; Donnan, Erica N.; Friesen, Laurel; Listernick, Zoe; Mogni, Benjamin; Pandolfino, John E.

    2015-01-01

    Background & Aims The functional lumen imaging probe (FLIP) could improve characterization of achalasia subtypes by detecting non-occlusive esophageal contractions not observed with standard manometry. We aimed to evaluate for esophageal contractions during volumetric distention in patients with achalasia using FLIP topography. Methods Fifty one treatment-naïve patients with achalasia, defined and sub-classified by high-resolution esophageal pressure topography, and 10 asymptomatic individuals (controls) were evaluated with the FLIP during endoscopy. During stepwise distension, simultaneous intra-bag pressures and 16 channels of cross-sectional areas were measured; data were exported to software that generated FLIP topography plots. Esophageal contractility was identified by noting periods of reduced luminal diameter. Esophageal contractions were further characterized by propagation direction, repetitiveness, and based on whether they were occluding or non-occluding. Results Esophageal contractility was detected in all 10 controls: 8/10 had repetitive, antegrade, contractions and 9/10 had occluding contractions. Contractility was detected in 27% (4/15) of patients with type I achalasia and 65% (18/26, including 9 with occluding contractions) of patients with type II achalasia. Contractility was detected in all 10 patients with type III achalasia; 8 of these patients had a pattern of contractility not observed in controls (repetitive, retrograde contractions). Conclusions Esophageal contractility not observed with manometry can be detected in patients with achalasia using FLIP topography. The presence and patterns of contractility detected with FLIP topography may represent variations in pathophysiology, such as mechanisms of pan-esophageal pressurization in patients with type II achalasia. These findings could have implications for additional sub-classification to supplement prediction of the achalasia disease course. PMID:26278501

  13. Photoaffinity labeling of the lumenal K+ site of the gastric (H+ + K+)-ATPase

    International Nuclear Information System (INIS)

    Keeling, D.J.; Fallowfield, C.; Lawrie, K.M.; Saunders, D.; Richardson, S.; Ife, R.J.

    1989-01-01

    A photoaffinity label for the lumenal K+ site of the gastric (H+ + K+)-ATPase has been identified. Seven azido derivatives based upon the reversible K+ site inhibitor SCH 28080 were studied, one of which, m-ATIP (8-(3-azidophenylmethoxy)-1,2,3-trimethylimidazo[1,2-a] pyridinium iodide), was subsequently synthesized in radiolabeled form. In the absence of UV irradiation, m-ATIP inhibited K+ -stimulated ATPase activity in lyophilized gastric vesicles competitively with respect to K+, with a Ki value of 2.4 microM at pH 7.0. Irradiation of lyophilized gastric vesicles at pH 7.0 with [ 14 C]m-ATIP in the presence of 0.2 mM ATP resulted in a time-dependent inactivation of ATPase activity that was associated with an incorporation of radioactivity into a 100-kDa polypeptide representing the catalytic subunit of the (H+ + K+)-ATPase. Both inactivation and incorporation were blocked in the presence of 10 mM KCl but not with 10 mM NaCl, consistent with interaction at the K+ site. The level of incorporation required to produce complete inhibition of ATPase activity was 1.9 +/- 0.2 times the number of catalytic phosphorylation sites in the same preparation. Tryptic digestion of gastric vesicle membranes, labeled with [ 14 C]m-ATIP, failed to release the radioactivity from the membranes suggesting that the site of interaction was close to or within the membrane-spanning sections of this ion pump

  14. Gastric washing by distilled water can reduce free gastric cancer cells exfoliated into the stomach lumen.

    Science.gov (United States)

    Ohki, Atsuko; Abe, Nobutsugu; Yoshimoto, Eri; Hashimoto, Yoshikazu; Takeuchi, Hirohisa; Nagao, Gen; Masaki, Tadahiko; Mori, Toshiyuki; Ohkura, Yasuo; Sugiyama, Masanori

    2018-04-25

    Intragastric free cancer cells in patients with gastric cancer have rarely been studied. The purpose of this study was to investigate the detection rate of intragastric free cancer cells in gastric washes using two types of solutions during endoscopic examination. We further clarified risk factors affecting the presence of exfoliated free cancer cells. A total of 175 patients with gastric cancer were enrolled. Lactated Ringer's solution (N = 89) or distilled water (DW; N = 86) via endoscopic working channel was sprayed onto the tumor surface, and the resultant fluid was collected for cytological examination. We compared the cancer-cell positivity rate between the two (Ringer and DW) groups. We also tested the correlation between cancer-cell positivity and clinicopathological factors in the Ringer group to identify risk factors for the presence of exfoliated cancer cells. The cancer-cell positivity rate was significantly higher in the Ringer group than that in the DW group (58 vs 6%). Cytomorphology in the Ringer group was well maintained, but not in the DW group. The larger tumor size (≥ 20 mm) and positive lymphatic involvement were significant risk factors of exfoliated free cancer cells. Cancer cells can be highly exfoliated from the tumor surface into the gastric lumen by endoscopic irrigation in large gastric cancer with lymphatic involvement. Gastric washing by DW can lead to cytoclasis of free cancer cells; therefore, it may minimize the possibility of cancer-cell seeding in procedures carrying potential risks of tumor-cell seeding upon transluminal communication, such as endoscopic full-thickness resection and laparoscopy-endoscopy cooperative surgery.

  15. Polymeric immunoglobulin receptor in intestinal immune defense against the lumen-dwelling protozoan parasite Giardia.

    Science.gov (United States)

    Davids, Barbara J; Palm, J E Daniel; Housley, Michael P; Smith, Jennifer R; Andersen, Yolanda S; Martin, Martin G; Hendrickson, Barbara A; Johansen, Finn-Eirik; Svärd, Staffan G; Gillin, Frances D; Eckmann, Lars

    2006-11-01

    The polymeric Ig receptor (pIgR) is conserved in mammals and has an avian homologue, suggesting evolutionarily important functions in vertebrates. It transports multimeric IgA and IgM across polarized epithelia and is highly expressed in the intestine, yet little direct evidence exists for its importance in defense against common enteric pathogens. In this study, we demonstrate that pIgR can play a critical role in intestinal defense against the lumen-dwelling protozoan parasite Giardia, a leading cause of diarrheal disease. The receptor was essential for the eradication of Giardia when high luminal IgA levels were required. Clearance of Giardia muris, in which IgA plays a dominant role, was severely compromised in pIgR-deficient mice despite significant fecal IgA output at 10% of normal levels. In contrast, eradication of the human strain Giardia lamblia GS/M, for which adaptive immunity is less IgA dependent in mice, was unaffected by pIgR deficiency, indicating that pIgR had no physiologic role when lower luminal IgA levels were sufficient for parasite elimination. Immune IgA was greatly increased in the serum of pIgR-deficient mice, conferred passive protection against Giardia, and recognized several conserved giardial Ags, including ornithine carbamoyltransferase, arginine deiminase, alpha-enolase, and alpha- and beta-giardins, that are also detected in human giardiasis. Corroborative observations were made in mice lacking the J chain, which is required for pIgR-dependent transepithelial IgA transport. These results, together with prior data on pIgR-mediated immune neutralization of luminal cholera toxin, suggest that pIgR is essential in intestinal defense against pathogenic microbes with high-level and persistent luminal presence.

  16. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  17. Researching YouTube

    OpenAIRE

    Arthurs, Jane; Drakopoulou, Sophia; Gandini, Alessandro

    2018-01-01

    ‘Researching YouTube’ introduces the special issue of Convergence which arose out of an international academic conference on YouTube that was held in London at Middlesex University in September 2016. The conference aimed to generate a robust overview of YouTube’s changing character and significance after its first ten years of development by creating a productive dialogue between speakers from different disciplines and cultures, and between YouTube-specific research and wider debates in media...

  18. Tubing crimping pliers

    Science.gov (United States)

    Lindholm, G.T.

    1981-02-27

    The disclosure relates to pliers and more particularly to pliers for crimping two or more pieces of copper tubing together prior to their being permanently joined by brazing, soldering or the like. A die containing spring-loaded pins rotates within a cammed ring in the head of the pliers. As the die rotates, the pins force a crimp on tubing held within the pliers.

  19. The Maui International Double Star Conference

    Science.gov (United States)

    Genet, Russell

    2013-04-01

    A three-day double star conference in February, 2013, covered double star observations from simple eyepiece astrometry of wide binaries, with orbital periods of centuries, to amplitude interferometry of binaries with periods measured in days or even hours. A wide range of participants, from students and amateurs to professionals shared their perspectives in panel discussions. This was the first conference of the newly-formed International Association of Double Star Observers (IADSO). PDFs of 22 of the talks and YouTube links to 23 of the talks and panels are available at www.IADSO.org.

  20. Pressure tube reactor

    International Nuclear Information System (INIS)

    Seki, Osamu; Kumasaka, Katsuyuki.

    1988-01-01

    Purpose: To remove the heat of reactor core using a great amount of moderators at the periphery of the reactor core as coolants. Constitution: Heat of a reactor core is removed by disposing a spontaneous recycling cooling device for cooling moderators in a moderator tank, without using additional power driven equipments. That is, a spontaneous recycling cooling device for cooling the moderators in the moderator tank is disposed. Further, the gap between the inner wall of a pressure tube guide pipe disposed through the vertical direction of a moderator tank and the outer wall of a pressure tube inserted through the guide pipe is made smaller than the rupture distortion caused by the thermal expansion upon overheating of the pressure tube and greater than the minimum gap required for heat shiels between the pressure tube and the pressure tube guide pipe during usual operation. In this way, even if such an accident as can not using a coolant cooling device comprising power driven equipment should occur in the pressure tube type reactor, the rise in the temperature of the reactor core can be retarded to obtain a margin with time. (Kamimura, M.)

  1. Tube spacer grid for a heat-exchanger tube bundle

    International Nuclear Information System (INIS)

    Scheidl, H.

    1976-01-01

    A tube spacer grid for a heat-exchanger tube bundle is formed by an annular grid frame having a groove formed in its inner surface in which the interspaced grid bars have their ends positioned and held in interspaced relationship by short sections of tubes passed through holes axially formed in the grid frame so that the tubes are positioned between the ends of the grid bars in the grooves. The tube sections may be cut from the same tubes used to form the tube bundle. 5 claims, 3 drawing figures

  2. Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

    International Nuclear Information System (INIS)

    Izaki, Kenta; Yamaguchi, Masato; Matsumoto, Ippei; Shinzeki, Makoto; Ku, Yonson; Sugimura, Kazuro; Sugimoto, Koji

    2011-01-01

    A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas–kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor’s portal vein was anastomosed to the recipient’s inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our technique for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.

  3. Linear-regression convolutional neural network for fully automated coronary lumen segmentation in intravascular optical coherence tomography

    Science.gov (United States)

    Yong, Yan Ling; Tan, Li Kuo; McLaughlin, Robert A.; Chee, Kok Han; Liew, Yih Miin

    2017-12-01

    Intravascular optical coherence tomography (OCT) is an optical imaging modality commonly used in the assessment of coronary artery diseases during percutaneous coronary intervention. Manual segmentation to assess luminal stenosis from OCT pullback scans is challenging and time consuming. We propose a linear-regression convolutional neural network to automatically perform vessel lumen segmentation, parameterized in terms of radial distances from the catheter centroid in polar space. Benchmarked against gold-standard manual segmentation, our proposed algorithm achieves average locational accuracy of the vessel wall of 22 microns, and 0.985 and 0.970 in Dice coefficient and Jaccard similarity index, respectively. The average absolute error of luminal area estimation is 1.38%. The processing rate is 40.6 ms per image, suggesting the potential to be incorporated into a clinical workflow and to provide quantitative assessment of vessel lumen in an intraoperative time frame.

  4. Activity of LUMEN (1996-97) Understanding of PbWO4 Scintillator Characteristics and their Optimisation

    CERN Document Server

    Baccaro, Stefania; Borgia, Bruno; Cecilia, Angelica; Croci, S; Dafinei, Ioan; Diemoz, Marcella; Fabeni, P; Festinesi, Armando; Jarolímek, O; Longo, Egidio; Martini, M; Mihoková, E; Montecchi, Marco; Nikl, M; Nitsch, K; Organtini, Giovanni; Pazzi, G P; Spinolo, G; Vedda, A

    1998-01-01

    The aim of the LUMEN co-operation, supported by INFN, is to obtain ful experimental characterisation and deep expertise of heavy scintillator for high energy physics. The advantage of this collaboration was mainly in the complementary character of the experimental techniques available in the partner laboratories and in the availability of highly experienced scientists indifferent fields. Furthermore close feedback to technological laboratories preparing on request PWO samples appeared extremely helpful. The present paper reports on the most important results obtained during the LUMEN activity in 1996-97. The aim of the report is to provide also enough useful information for the PWO application and novel ideas to stimulate further interest for new detectors as well as application in different fields.

  5. Linear-regression convolutional neural network for fully automated coronary lumen segmentation in intravascular optical coherence tomography.

    Science.gov (United States)

    Yong, Yan Ling; Tan, Li Kuo; McLaughlin, Robert A; Chee, Kok Han; Liew, Yih Miin

    2017-12-01

    Intravascular optical coherence tomography (OCT) is an optical imaging modality commonly used in the assessment of coronary artery diseases during percutaneous coronary intervention. Manual segmentation to assess luminal stenosis from OCT pullback scans is challenging and time consuming. We propose a linear-regression convolutional neural network to automatically perform vessel lumen segmentation, parameterized in terms of radial distances from the catheter centroid in polar space. Benchmarked against gold-standard manual segmentation, our proposed algorithm achieves average locational accuracy of the vessel wall of 22 microns, and 0.985 and 0.970 in Dice coefficient and Jaccard similarity index, respectively. The average absolute error of luminal area estimation is 1.38%. The processing rate is 40.6 ms per image, suggesting the potential to be incorporated into a clinical workflow and to provide quantitative assessment of vessel lumen in an intraoperative time frame. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  6. The Use of Tygon Tubing Sterilized by Gamma Radiation in Heart-Lung By-Pass Machines

    Energy Technology Data Exchange (ETDEWEB)

    Alladine, M. F.; Gibbons, J. R. P. [London Chest Hospital, London (United Kingdom)

    1967-09-15

    Tygon tubing is a co-polymer polyvinyl chloride. This tubing is used throughout the circuit of our heart-lung by-pass machines and had been sterilized by autoclaving or exposure to ethylene oxide gas. Tubing sterilized by autoclaving was noted to have a decrease in tensile strength and the transparency of the tubing was affected. Sterilization by ethylene oxide had the disadvantage that gas was often present in the lumen of the tube when connected to the machine. Lengths of Tygon tubing were sterilized by gamma radiation at varying radiation levels and temperatures. Bacteriological studies were done on the tubing and estimation of tensile strength carried out. We have found that a level of radiation of 2. 5 to 3. 0 Mrad at 20°C produces little or no change in tensile strength and the tubing remains bacteriologically sterile. Tygon tubing sterilized in this way has now been used in over sixty heart-lung by-pass machine operations. (author)

  7. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound

    OpenAIRE

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Śpiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin

    2013-01-01

    Introduction Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. Aim To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Material and methods Two hundred and...

  8. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  9. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  10. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    Science.gov (United States)

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake [Nagasaki Univ. (Japan). School of Medicine; Narimatsu, Motoharu

    1997-08-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA{>=}5 cm, thickness of the false lumen of the AA{>=}1 cm, thickness of the false lumen of the AA{>=} that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  12. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    International Nuclear Information System (INIS)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake; Narimatsu, Motoharu.

    1997-01-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA≥5 cm, thickness of the false lumen of the AA≥1 cm, thickness of the false lumen of the AA≥ that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  13. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  14. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    Science.gov (United States)

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  15. Halloysite tubes as nanocontainers for anticorrosion coating with benzotriazole.

    Science.gov (United States)

    Abdullayev, Elshad; Price, Ronald; Shchukin, Dmitry; Lvov, Yuri

    2009-07-01

    Halloysite clay nanotubes were investigated as a tubular container for the corrosion inhibitor benzotriazole. Halloysite is a naturally occurring cylindrical clay mineral with an internal diameter in the nanometer range and a length up to several micrometers, yielding a high-aspect-ratio hollow tube structure. Halloysite may be used as an additive in paints to produce a functional composite coating material. A maximum benzotriazole loading of 5% by weight was achieved for clay tubes of 50 nm external diameters and lumen of 15 nm. Variable release rates of the corrosion inhibitor were possible in a range between 5 and 100 h, as was demonstrated by formation of stoppers at tube openings. The anticorrosive performance of the sol-gel coating and paint loaded with 2-5% of halloysite-entrapped benzotriazole was tested on copper and on 2024-aluminum alloy by direct exposure of the metal plates to corrosive media. Kinetics of the corrosion spot formation at the coating defects was analyzed by the scanning vibrating electrode technique, and an essential damping of corrosion development was demonstrated for halloysite-loaded samples.

  16. Double Chooz

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Christian [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2006-05-15

    The goal of the Double Chooz reactor neutrino experiment is to search for the neutrino mixing parameter {theta}{sub 13}. Double Chooz will use two identical detectors at 150 m and 1.05 km distance from the reactor cores. The near detector is used to monitor the reactor {nu}-bar {sub e} flux while the second is dedicated to the search for a deviation from the expected (1/distance){sup 2} behavior. This two detector concept will allow a relative normalization systematic error of ca. 0.6 %. The expected sensitivity for sin{sup 2}2{theta}{sub 13} is then in the range 0.02 - 0.03 after three years of data taking. The antineutrinos will be detected in a liquid scintillator through the capture on protons followed by a gamma cascade, produced by the neutron capture on Gd.

  17. Double supergeometry

    Energy Technology Data Exchange (ETDEWEB)

    Cederwall, Martin [Division for Theoretical Physics, Department of Physics, Chalmers University of Technology,SE 412 96 Gothenburg (Sweden)

    2016-06-27

    A geometry of superspace corresponding to double field theory is developed, with type I I supergravity in D=10 as the main example. The formalism is based on an orthosymplectic extension OSp(d,d|2s) of the continuous T-duality group. Covariance under generalised super-diffeomorphisms is manifest. Ordinary superspace is obtained as a solution of the orthosymplectic section condition. A systematic study of curved superspace Bianchi identities is performed, and a relation to a double pure spinor superfield cohomology is established. A Ramond-Ramond superfield is constructed as an infinite-dimensional orthosymplectic spinor. Such objects in minimal orbits under the OSp supergroup (“pure spinors”) define super-sections.

  18. Double ambidexterity

    DEFF Research Database (Denmark)

    Kaulio, Matti; Thorén, Kent; Rohrbeck, René

    2017-01-01

    We leverage the business model innovation and ambidexterity literature to investigate a contradictory case, the Swedish-Finnish Telecom operator TeliaSonera. Despite being challenged by three major disruptions, the company not only still exists but also enjoys remarkably good financial performance....... Building on extant archival data and interviews, we carefully identify and map 26 organizational responses during 1992–2016. We find that the firm has overcome three critical phases by experimenting and pioneering with portfolios of business models and/or technological innovations. We describe...... this behaviour as double ambidexterity. We use an in-depth case study to conceptualize double ambidexterity and discuss its impact on the business's survival and enduring success....

  19. Calreticulin is required for calcium homeostasis and proper pollen tube tip growth in Petunia.

    Science.gov (United States)

    Suwińska, Anna; Wasąg, Piotr; Zakrzewski, Przemysław; Lenartowska, Marta; Lenartowski, Robert

    2017-05-01

    Calreticulin is involved in stabilization of the tip-focused Ca 2+ gradient and the actin cytoskeleton arrangement and function that is required for several key processes driving Petunia pollen tube tip growth. Although the precise mechanism is unclear, stabilization of a tip-focused calcium (Ca 2+ ) gradient seems to be critical for pollen germination and pollen tube growth. We hypothesize that calreticulin (CRT), a Ca 2+ -binding/buffering chaperone typically residing in the lumen of the endoplasmic reticulum (ER) of eukaryotic cells, is an excellent candidate to fulfill this role. We previously showed that in Petunia pollen tubes growing in vitro, CRT is translated on ER membrane-bound ribosomes that are abundant in the subapical zone of the tube, where CRT's Ca 2+ -buffering and chaperone activities might be particularly required. Here, we sought to determine the function of CRT using small interfering RNA (siRNA) to, for the first time in pollen tubes growing in vitro, knockdown expression of a gene. We demonstrate that siRNA-mediated post-transcriptional silencing of Petunia hybrida CRT gene (PhCRT) expression strongly impairs pollen tube growth, cytoplasmic zonation, actin cytoskeleton organization, and the tip-focused Ca 2+ gradient. Moreover, reduction of CRT alters the localization and disturbs the structure of the ER in abnormally elongating pollen tubes. Finally, cytoplasmic streaming is inhibited, and most of the pollen tubes rupture. Our data clearly show an interplay between CRT, Ca 2+ gradient, actin-dependent cytoplasmic streaming, organelle positioning, and vesicle trafficking during pollen tube elongation. Thus, we suggest that CRT functions in Petunia pollen tube growth by stabilizing Ca 2+ homeostasis and acting as a chaperone to assure quality control of glycoproteins passing through the ER.

  20. Tube plug removal machine

    International Nuclear Information System (INIS)

    Hawkins, P.J.

    1987-01-01

    In a nuclear steam generator wherein some faulty tubes have been isolated by mechanical plugging, to remove a selected plug without damaging the associated tube, a plug removal machine is used. The machine drills into a plug portion with a tap drill bit having a drill portion a tap portion and a threaded portion, engaging that plug portion with the threaded portion after the drilled hole has been threaded by the tap portion thereof, and removing a portion of the plug in the tube with a counterbore drill bit mounted concentrically about the tap drill bit. A trip pin and trip spline disengage the tap drill bit from the motor. The counterbore drill bit is thereafter self-centered with respect to the tube and plug about the now stationary tap drill bit. After a portion of the plug has been removed by the counterbore drill bit, pulling on the top drill bit by grippers on slots will remove the remaining plug portion from the tube. (author)

  1. Categorising YouTube

    Directory of Open Access Journals (Sweden)

    Thomas Mosebo Simonsen

    2011-09-01

    Full Text Available This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC of YouTube. The article investigates the construction of navigationprocesses on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within the interacting relationship of new and old genres are discussed. It is argued that the utility of a conventional categorical system is primarily of analytical and theoretical interest rather than as a practical instrument.

  2. Measuring of tube expansion

    International Nuclear Information System (INIS)

    Vogeleer, J. P.

    1985-01-01

    The expansion of the primary tubes or sleeves of the steam generator of a nuclear reactor plant are measured while the tubes or sleeves are being expanded. A primary tube or sleeve is expanded by high pressure of water which flows through a channel in an expander body. The water is supplied through an elongated conductor and is introduced through a connector on the shank connected to the conductor at its outer end. A wire extends through the mandrel and through the conductor to the end of the connector. At its inner end the wire is connected to a tapered pin which is subject to counteracting forces produced by the pressure of the water. The force on the side where the wire is connected to the conductor is smaller than on the opposite side. The tapered pin is moved in the direction of the higher force and extrudes the wire outwardly of the conductor. The tapered surface of the tapered pin engages transverse captive plungers which are maintained in engagement with the expanding tube or sleeve as they are moved outwardly by the tapered pin. The wire and the connector extend out of the generator and, at its outer end, the wire is connected to an indicator which measures the extent to which the wire is moved by the tapered pin, thus measuring the expansion of the tube or sleeve as it progresses

  3. Square through tube

    International Nuclear Information System (INIS)

    Akita, Junji; Honma, Toei.

    1975-01-01

    Object: To provide a square through tube involving thermal movement in pipelines such as water supply pump driving turbine exhaust pipe (square-shaped), which is wide in freedom with respect to shape and dimension thereof for efficient installation at site. Structure: In a through tube to be airtightly retained for purpose of decontamination in an atomic power plant, comprising a seal rubber plate, a band and a bolt and a nut for securing said plate, the seal rubber plate being worked into the desired shape so that it may be placed in intimate contact with the concrete floor surface by utilization of elasticity of rubber, thereby providing airtightness at a corner portion of the square tube. (Kamimura, M.)

  4. SG tube identification

    International Nuclear Information System (INIS)

    Hoogstraten, P. van

    1994-01-01

    A ''Tracker'' system is described which is designed to identify any tube in a reactor steam generator quickly and safely. Occupational radiation doses to maintenance workers are reduced by using a Tracker and emergency down times are shortened. The system employs a television camera and light source in a stainless steel box with a large window. Both the camera and spotlight can be panned and tilted to reach any point on the tubesheet and are remotely controlled. An operator at a safe working distance can identify any tube visible on a real time video by comparison with the tubesheet pattern stored earlier in the computer memory. The identified tube can then be spotlighted and dealt with quickly by a maintenance worker inside the channel head. (UK)

  5. Traveling wave tube and method of manufacture

    Science.gov (United States)

    Vancil, Bernard K. (Inventor)

    2004-01-01

    A traveling wave tube includes a glass or other insulating envelope having a plurality of substantially parallel glass rods supported therewithin which in turn support an electron gun, a collector and an intermediate slow wave structure. The slow wave structure itself provides electrostatic focussing of a central electron beam thereby eliminating the need for focussing magnetics and materially decreasing the cost of construction as well as enabling miniaturization. The slow wave structure advantageously includes cavities along the electron beam through which the r.f. energy is propagated, or a double, interleaved ring loop structure supported by dielectric fins within a ground plane cylinder disposed coaxially within the glass envelope.

  6. PRODUCTION OF URANIUM TUBING

    Science.gov (United States)

    Creutz, E.C.

    1958-04-15

    The manufacture of thin-walled uranium tubing by the hot-piercing techique is described. Uranium billets are preheated to a temperature above 780 d C. The heated billet is fed to a station where it is engaged on its external surface by three convex-surfaced rotating rollers which are set at an angle to the axis of the billet to produce a surface friction force in one direction to force the billet over a piercing mandrel. While being formed around the mandrel and before losing the desired shape, the tube thus formed is cooled by a water spray.

  7. Guide tube sleeve

    International Nuclear Information System (INIS)

    Attix, D.J.

    1983-01-01

    The invention increases the operating capacity of a nuclear reactor by causing a modification in the flow pattern of the coolant which enhances the coolant's effectiveness. The apparatus provides a thin-walled tubular sleeve closely surrounding but not attached to the exterior surface of a guide tube in a fuel assembly. The wall of the sleeve has tabs projecting outwardly into adjacent flow channels. The sleeve is attached to the wall of a cellular void through which passes the guide tube associated with said sleeve. The tabs increase the flow of water in the channel and thus increase the heat transfer

  8. Pressure tube type research reactor

    International Nuclear Information System (INIS)

    Ueda, Hiroshi.

    1976-01-01

    Object: To prevent excessive heat generation due to radiation of a pressure tube vessel. Structure: A pressure tube encasing therein a core comprises a dual construction comprising inner and outer tubes coaxially disposed. High speed cooling water is passed through the inner tube for cooling. In addition, in the outer periphery of said outer tube there is provided a forced cooling tube disposed coaxially thereto, into which cooling fluid, for example, such as moderator or reflector is forcibly passed. This forced cooling tube has its outer periphery surrounded by the vessel into which moderator or reflector is fed. By the provision of the dual construction of the pressure tube and the forced cooling tube, the vessel may be prevented from heat generation. (Ikeda, J.)

  9. Finite Element Analysis and Crashworthiness Optimization of Foam-filled Double Circular under Oblique Loading

    Directory of Open Access Journals (Sweden)

    Fauzan Djamaluddin

    Full Text Available Abstract Finite element analysis and optimization design carry out for the quasi static responses of foam-filled double circular tube is presented in this paper. In the investigation of the crashworthiness capability, some aspects were considered for variations in geometry parameters of tubes and the loading condition to investigate the crashworthiness capability. Empty, foam-filled, and full foam-filled doublé tubes of thin walled structures were observed subjected to oblique impact (0˚ - 40˚. The numerical solution was used to determine the crashworthiness parameters. In addition, NSGA II and Radial Basis Function were used to optimize the crashworthiness capability of tubes. In conclution, the crash performaces of foam-filled double tube is better than the other structures in this work. The outcome that expected is the new design information of various kinds of cylindrical tubes for energy absorber application.

  10. Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun; Fujioka, Chikako; Kiguchi, Masao; Kohno, Shingo [Hiroshima University Hospital, Department of Clinical Radiology, Hiroshima (Japan); Yamamoto, Hideya; Kitagawa, Toshiro [Hiroshima University, Department of Molecular and Internal Medicine, Division of Clinical Medical Science, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan); Ito, Katsuhide [Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan)

    2009-10-15

    The purpose of this study was to compare coronary 64-slice CT angiography (CTA) protocols, specifically prospective electrocardiograph (ECG)-triggered and retrospective ECG-gated CT acquisition performed using a tube voltage of 140 kV and 120 kV, regarding intracoronary stent imaging. Coronary artery stents (n=12) with artificial in-stent restenosis (50% luminal reduction, 40 HU) on a cardiac phantom were examined by CT at heart rates of 50-75 beats per minute (bpm). The subjective visibility of in-stent restenosis was evaluated with a three-point scale (1 clearly visible, 2 visible, and 3 not visible), and artificial lumen narrowing [(inner stent diameter - measured lumen diameter)/inner stent diameter], lumen attenuation increase ratio [(in-stent attenuation - coronary lumen attenuation)/coronary lumen attenuation], and signal-to-noise ratio of in-stent lumen were determined. The effective dose was estimated. The artificial lumen narrowing (mean 43%), the increase of lumen attenuation (mean 46%), and signal-to-noise ratio (mean 7.8) were not different between CT acquisitions (p=0.12-0.91). However, the visibility scores of in-stent restenosis were different (p<0.05) between ECG-gated CTA techniques: (a) 140-kV prospective (effective dose 4.6 mSv), 1.6; (b) 120-kV prospective (3.3 mSv), 1.8; (c) 140-kV retrospective (16.4-18.8 mSv), 1.9; and (d) 120-kV retrospective (11.0-13.4 mSv), 1.9. Thus, 140-kV prospective ECG-triggered CTA improves coronary in-stent restenosis visibility at a lower radiation dose compared with retrospective ECG-gated CTA. (orig.)

  11. Why does the lumen maintenance of sodium-scandium metal halide lamps improve by VHF operation?

    International Nuclear Information System (INIS)

    Van Erk, W; Luijks, G M J F; Hitchcock, W

    2011-01-01

    Lifetime experiments show that sodium-scandium metal halide lamps perform better on very high frequency (VHF) drivers than on low frequency (LF) constant wattage autotransformer (CWA) ballasts. The question why, will be addressed with focus on arc tube aspects. It is argued that at high frequency operation sodium loss is less, and that the absence of thermal fluctuations in the electrode tip causes less damage and cracking to this part of the electrode. Sudden lm W -1 drops, observed with CWA-operated lamps, most probably occur when the arc attaches on such a corroded and cracked surface. Thorium is effective as an emitter both in the CWA and the VHF operation mode, despite the absence of cataphoretic transport to the cathode in the VHF case.

  12. Why does the lumen maintenance of sodium-scandium metal halide lamps improve by VHF operation?

    Energy Technology Data Exchange (ETDEWEB)

    Van Erk, W [Philips Lighting, Sondervick 47, 5505 NB Veldhoven (Netherlands); Luijks, G M J F [Advanced Development Lighting, Philips Lighting, PO Box 80020, 5600 JM Eindhoven (Netherlands); Hitchcock, W, E-mail: Gerard.luijks@philips.com [Philips Lighting Company, 7265 Route 54, Bath, NY 14810 (United States)

    2011-06-08

    Lifetime experiments show that sodium-scandium metal halide lamps perform better on very high frequency (VHF) drivers than on low frequency (LF) constant wattage autotransformer (CWA) ballasts. The question why, will be addressed with focus on arc tube aspects. It is argued that at high frequency operation sodium loss is less, and that the absence of thermal fluctuations in the electrode tip causes less damage and cracking to this part of the electrode. Sudden lm W{sup -1} drops, observed with CWA-operated lamps, most probably occur when the arc attaches on such a corroded and cracked surface. Thorium is effective as an emitter both in the CWA and the VHF operation mode, despite the absence of cataphoretic transport to the cathode in the VHF case.

  13. CALiPER Retail Lamps Study 3.2: Lumen and Chromaticity Maintenance of LED A Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-31

    This CALiPER report examines lumen depreciation and color shift of 17 different A lamps in steady-state conditions (15 LED, 1 CFL, 1 halogen). The goal of this investigation was to examine the long-term performance of complete LED lamps relative to benchmark halogen and CFL lamps—in this case, A lamps emitting approximately 800 lumens operated continuously at a relatively high ambient temperature of 45°C.

  14. Tube-dwelling invertebrates

    NARCIS (Netherlands)

    Hölker, Franz; Vanni, Michael J.; Kuiper, Jan J.; Meile, Christof; Grossart, Hans Peter; Stief, Peter; Adrian, Rita; Lorke, Andreas; Dellwig, Olaf; Brand, Andreas; Hupfer, Michael; Mooij, Wolf M.; Nützmann, Gunnar; Lewandowski, Jörg

    2015-01-01

    There is ample evidence that tube-dwelling invertebrates such as chironomids significantly alter multiple important ecosystem functions, particularly in shallow lakes. Chironomids pump large water volumes, and associated suspended and dissolved substances, through the sediment and thereby compete

  15. Cladding tube manufacturing technology

    International Nuclear Information System (INIS)

    Hahn, R.; Jeong, Y. H.; Baek, B. J.; Kim, K. H.; Kim, S. J.; Choi, B. K.; Kim, J. M.

    1999-04-01

    This report gives an overview of the manufacturing routine of PWR cladding tubes. The routine essentially consists of a series of deformation and annealing processes which are necessary to transform the ingot geometry to tube dimensions. By changing shape, microstructure and structure-related properties are altered simultaneously. First, a short overview of the basics of that part of deformation geometry is given which is related to tube reducing operations. Then those processes of the manufacturing routine which change the microstructure are depicted, and the influence of certain process parameters on microstructure and material properties are shown. The influence of the resulting microstructure on material properties is not discussed in detail, since it is described in my previous report A lloy Development for High Burnup Cladding . Because of their paramount importance still up to now, and because manufacturing data and their influence on properties for other alloys are not so well established or published, the descriptions are mostly related to Zry4 tube manufacturing, and are only in short for other alloys. (author). 9 refs., 46 figs

  16. Thoughts on accelerator tubes

    International Nuclear Information System (INIS)

    Larson, J.D.

    1978-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators

  17. Tracheostomy tube - speaking

    Science.gov (United States)

    ... with others. However, you can learn how to speak with a tracheostomy tube. It just takes practice. There ... If it is hard to speak with a trach in place, special devices can help you learn to create sounds. One-way valves, called speaking valves, are placed ...

  18. Thoughts of accelerator tubes

    International Nuclear Information System (INIS)

    Larson, J.D.

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators

  19. Cladding tube manufacturing technology

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, R. [Kraftwerk Union AG, Mulheim (Germany); Jeong, Y.H.; Baek, B.J.; Kim, K.H.; Kim, S.J.; Choi, B.K.; Kim, J.M. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-04-01

    This report gives an overview of the manufacturing routine of PWR cladding tubes. The routine essentially consists of a series of deformation and annealing processes which are necessary to transform the ingot geometry to tube dimensions. By changing shape, microstructure and structure-related properties are altered simultaneously. First, a short overview of the basics of that part of deformation geometry is given which is related to tube reducing operations. Then those processes of the manufacturing routine which change the microstructure are depicted, and the influence of certain process parameters on microstructure and material properties are shown. The influence of the resulting microstructure on material properties is not discussed in detail, since it is described in my previous report 'Alloy Development for High Burnup Cladding.' Because of their paramount importance still up to now, and because manufacturing data and their influence on properties for other alloys are not so well established or published, the descriptions are mostly related to Zry4 tube manufacturing, and are only in short for other alloys. (author). 9 refs., 46 figs.

  20. Disc-retained tubes for radiologically inserted gastrostomy (RIG): Not up to the job?

    International Nuclear Information System (INIS)

    Kibriya, N.; Wilbraham, L.; Mullan, D.; Puro, P.; Vasileuskaya, S.; Edwards, D.W.; Laasch, H.-U.

    2013-01-01

    Aim: To assess the insertion procedure and performance of disc-retained gastrostomy tubes, recording complications and accidental displacements by prospective audit, and to determine whether primary placement of the tube off-licence was feasible. Materials and methods: Disc-retained 12 F single-lumen Monarch gastrostomy tubes (Enteral UK, Selby, UK) were inserted by three gastrointestinal interventional radiologists in a supra-regional cancer centre. The 12 F tubes required a 20 F peel-away sheath with four-point gastropexy fixation and were placed under conscious sedation, using electrocardiogram (EEG) bispectral index monitoring. Follow-up was performed in an in-house gastrostomy drop-in clinic at 1 week and 1 month, supplemented with weekly telephone follow-up. Patients also had open access to the gastrostomy drop-in clinic for immediate advice and complication management. Results: Eighteen patients underwent primary insertion of a Monarch gastrostomy tube over 5 months. A total of 6/18 (33%) tubes displaced; 4/18 (22%) completely, 2/18 (11%) occult into the peritoneum. Four of 18 (22%) patients developed infection at the stoma site. Due to the unexpectedly poor performance of the tube, the study was terminated early. Conclusion: Initial experience with the Monarch disc-retained gastrostomy tube demonstrates it unsuitable for primary placement with current protocols. In view of the potentially serious complications, the Medicines and Healthcare Products Regulatory Agency (MHRA) has been informed. A request has been made to the distributer to reassess the tube design and/or review the procedure promoted for primary placement

  1. Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Inoue, Toshihisa; Watanabe, Shigeru; Sakurada, Hideki; Ono, Katsuhiro; Urano, Miharu; Hijikata, Yasuyoshi; Saito, Isao; Masuda, Yoshiaki

    2000-01-01

    In 21 patients with chronic aortic dissections and proven patent false lumens, the flow volume and flow patterns in the patent false lumens was evaluated using velocity-encoded cine magnetic resonance imaging (VENC-MRI) and the relationship between the flow characteristics and aortic enlargement was retrospectively examined. Flow patterns in the false lumen were divided into 3 groups: pattern A with primarily antegrade flow (n=6), pattern R with primarily retrograde flow (n=3), and pattern B with bidirectional flow (n=12). In group A, the rate of flow volume in the false lumen compared to the total flow volume in true and false lumens (%TFV) and the average rate of enlargement of the maximum diameter of the dissected aorta per year (ΔD) were significantly greater than in groups R and B (%TFV: 74.1±0.07 vs 15.2±0.03 vs 11.8±0.04, p<0.01; ΔD: 3.62±0.82 vs 0 vs 0.58±0.15 mm/year, p<0.05, respectively). There was a significant correlation between %TFV and ΔD (r=0.79, p<0.0001). Evaluation of flow volume and flow patterns in the patent false lumen using VENC-MRI may be useful for predicting enlargement of the dissected aorta. (author)

  2. Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Toshihisa; Watanabe, Shigeru; Sakurada, Hideki; Ono, Katsuhiro; Urano, Miharu; Hijikata, Yasuyoshi; Saito, Isao; Masuda, Yoshiaki [Chiba Univ. (Japan). School of Medicine

    2000-10-01

    In 21 patients with chronic aortic dissections and proven patent false lumens, the flow volume and flow patterns in the patent false lumens was evaluated using velocity-encoded cine magnetic resonance imaging (VENC-MRI) and the relationship between the flow characteristics and aortic enlargement was retrospectively examined. Flow patterns in the false lumen were divided into 3 groups: pattern A with primarily antegrade flow (n=6), pattern R with primarily retrograde flow (n=3), and pattern B with bidirectional flow (n=12). In group A, the rate of flow volume in the false lumen compared to the total flow volume in true and false lumens (%TFV) and the average rate of enlargement of the maximum diameter of the dissected aorta per year ({delta}D) were significantly greater than in groups R and B (%TFV: 74.1{+-}0.07 vs 15.2{+-}0.03 vs 11.8{+-}0.04, p<0.01; {delta}D: 3.62{+-}0.82 vs 0 vs 0.58{+-}0.15 mm/year, p<0.05, respectively). There was a significant correlation between %TFV and {delta}D (r=0.79, p<0.0001). Evaluation of flow volume and flow patterns in the patent false lumen using VENC-MRI may be useful for predicting enlargement of the dissected aorta. (author)

  3. The Effects of Distention and Obstruction on the Accumulation of Fluid in the Lumen of Small Bowel of Dogs

    Science.gov (United States)

    Mishra, Nand K.; Appert, Hubert E.; Howard, John M.

    1974-01-01

    Fluid accumulation in either the obstructed upper or lower intestinal segments of the dog was found in most animals to be negligible. Distention pressures of 25 cm of water tended to reduce fluid accumulation within the intestinal lumen. These studies suggest that if the dog is comparable to man, the intraluminal accumulation of fluid in the obstructed small bowel of man might be due to alterations in blood supply to the intestine, rather than to obstruction per se, or the accumulated fluid originates proximal to the jejunum. PMID:4419581

  4. 3D time-lapse analysis of Rab11/FIP5 complex: spatiotemporal dynamics during apical lumen formation.

    Science.gov (United States)

    Mangan, Anthony; Prekeris, Rytis

    2015-01-01

    Fluorescent imaging of fixed cells grown in two-dimensional (2D) cultures is one of the most widely used techniques for observing protein localization and distribution within cells. Although this technique can also be applied to polarized epithelial cells that form three-dimensional (3D) cysts when grown in a Matrigel matrix suspension, there are still significant limitations in imaging cells fixed at a particular point in time. Here, we describe the use of 3D time-lapse imaging of live cells to observe the dynamics of apical membrane initiation site (AMIS) formation and lumen expansion in polarized epithelial cells.

  5. Prediction of Lumen Output and Chromaticity Shift in LEDs Using Kalman Filter and Extended Kalman Filter Based Models

    Energy Technology Data Exchange (ETDEWEB)

    Lall, Pradeep; Wei, Junchao; Davis, J Lynn

    2014-06-24

    Abstract— Solid-state lighting (SSL) luminaires containing light emitting diodes (LEDs) have the potential of seeing excessive temperatures when being transported across country or being stored in non-climate controlled warehouses. They are also being used in outdoor applications in desert environments that see little or no humidity but will experience extremely high temperatures during the day. This makes it important to increase our understanding of what effects high temperature exposure for a prolonged period of time will have on the usability and survivability of these devices. Traditional light sources “burn out” at end-of-life. For an incandescent bulb, the lamp life is defined by B50 life. However, the LEDs have no filament to “burn”. The LEDs continually degrade and the light output decreases eventually below useful levels causing failure. Presently, the TM-21 test standard is used to predict the L70 life of LEDs from LM-80 test data. Several failure mechanisms may be active in a LED at a single time causing lumen depreciation. The underlying TM-21 Model may not capture the failure physics in presence of multiple failure mechanisms. Correlation of lumen maintenance with underlying physics of degradation at system-level is needed. In this paper, Kalman Filter (KF) and Extended Kalman Filters (EKF) have been used to develop a 70-percent Lumen Maintenance Life Prediction Model for LEDs used in SSL luminaires. Ten-thousand hour LM-80 test data for various LEDs have been used for model development. System state at each future time has been computed based on the state space at preceding time step, system dynamics matrix, control vector, control matrix, measurement matrix, measured vector, process noise and measurement noise. The future state of the lumen depreciation has been estimated based on a second order Kalman Filter model and a Bayesian Framework. Life prediction of L70 life for the LEDs used in SSL luminaires from KF and EKF based models have

  6. Drift tubes of Linac 2

    CERN Multimedia

    Photographic Service

    1977-01-01

    Being redied for installation, those at the right are for tank 1, those on the left for tank 2. Contrary to Linac 1, which had drift-tubes supported on stems, here the tubes are suspended, for better mechanical stability.

  7. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ... *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the ...

  8. Tubing For Sampling Hydrazine Vapor

    Science.gov (United States)

    Travis, Josh; Taffe, Patricia S.; Rose-Pehrsson, Susan L.; Wyatt, Jeffrey R.

    1993-01-01

    Report evaluates flexible tubing used for transporting such hypergolic vapors as those of hydrazines for quantitative analysis. Describes experiments in which variety of tubing materials, chosen for their known compatibility with hydrazine, flexibility, and resistance to heat.

  9. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  10. Double-layer ion acceleration triggered by ion magnetization in expanding radiofrequency plasma sources

    International Nuclear Information System (INIS)

    Takahashi, Kazunori; Charles, Christine; Boswell, Rod W.; Fujiwara, Tamiya

    2010-01-01

    Ion energy distribution functions downstream of the source exit in magnetically expanding low-pressure plasmas are experimentally investigated for four source tube diameters ranging from about 5 to 15 cm. The magnetic-field threshold corresponding to a transition from a simple expanding plasma to a double layer-containing plasma is observed to increase with a decrease in the source tube diameter. The results demonstrate that for the four geometries, the double layer and the accelerated ion beam form when the ion Larmour radius in the source becomes smaller than the source tube radius, i.e., when the ions become magnetized in the source tube.

  11. A study on LMFBR steam generator design without tube failure propagation in water leak events

    International Nuclear Information System (INIS)

    Futagami, Satoshi; Hayafune, Hiroki; Fujimura, Ken; Sato, Mitsuru

    2009-01-01

    The major target performance of the SG for commercialized FBR is not only economic performance but also property protection performance. The candidate SG design will be selected at the end of JFY 2010. The straight double wall tube SG is one of the SG candidates for commercialized FBR, and other SG concepts were studied in this paper. In proposing an alternative SG, alternative technological measures with a double wall tube were investigated and included reinforcing the tube against wastage and quick detection of initial tube leaks. Alternative SG concept candidates for preventing tube failure propagation and mitigation of water leak accidents were proposed through a combination of technological measures. The candidates were then comparatively evaluated from the point of view of property protection performance, total weight, technological issues, and so on. A coated wall tube SG and protective wall tube SG were decided on as the alternative SGs because of superior property protection performance and with the technological issues. At the end of JFY 2010, the straight double wall tube SG will be decided upon as the result of R and D activities, and alternative SGs evaluated in feasibility studies. A plan for studying feasibility with the technological issues of the alternative SG was proposed. (author)

  12. Expansion lyre-shaped tube

    International Nuclear Information System (INIS)

    Andro, Jean.

    1973-01-01

    The invention relates the expansion lyre-shaped tube portions formed in dudgeoned tubular bundles between two bottom plates. An expansion lyre comprises at least two sets of tubes of unequal lengths coplanar and symmetrical with respect to the main tube axis, with connecting portions between the tubes forming said sets. The invention applies to apparatus such as heat exchangers, heaters, superheaters or breeders [fr

  13. Experimental Study of Flow Boiling Heat Transfer in a Horizontal Microfin Tube

    OpenAIRE

    Yu, Jian; Koyama, Shigeru; Momoki, Satoru

    1995-01-01

    An experimental study on flow boiling heat transfer in a horizontal microfin tube is conducted with pure refrigerants HFC134a, HCFC123 and HCFC22 using a water-heated double-tube type test section. The test microfin tube is a copper tube having the following dimensions: 8.37mm mean inside diameter, 0.168mm fin height, 60fin number and 18 degree of helix angle. The local heat transfer coefficients for both counter and parallel flows are measured in a range of heat flux of 1 to 93W/m^2, mass ve...

  14. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  15. Tube Length and Water Flow

    Directory of Open Access Journals (Sweden)

    Ben Ruktantichoke

    2011-06-01

    Full Text Available In this study water flowed through a straight horizontal plastic tube placed at the bottom of a large tank of water. The effect of changing the length of tubing on the velocity of flow was investigated. It was found that the Hagen-Poiseuille Equation is valid when the effect of water entering the tube is accounted for.

  16. Tubing cutter for tight spaces

    Science.gov (United States)

    Girala, A. S.

    1980-01-01

    Cutter requires few short swings of handle to rotate its cutting edge full 360 around tube. It will cut tubing installed in confined space that prevents free movement of conventional cutter. Cutter is snapped onto tube and held in place by spring-loaded clamp. Screw ratchet advances cutting wheel.

  17. Heat Exchanger Tube to Tube Sheet Joints Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    M. Iancu

    2013-03-01

    Full Text Available Paper presents the studies made by the authors above the tube to tube sheet fittings of heat exchanger with fixed covers from hydrofining oil reforming unit. Tube fittings are critical zones for heat exchangers failures. On a device made from material tube and tube sheet at real joints dimensions were establish axial compression force and traction force at which tube is extracted from expanded joint. Were used two shapes joints with two types of fittings surfaces, one with smooth hole of tube sheet and other in which on boring surface we made a groove. From extracted expanded tube zones were made samples for corrosion tests in order to establish the corrosion rate, corrosion potential and corrosion current in working mediums such as hydrofining oil and industrial water at different temperatures. The corrosion rate values and the temperature influence are important to evaluate joints durability and also the results obtained shows that the boring tube sheet shape with a groove on hole tube shape presents a better corrosion behavior then the shape with smooth hole tube sheet.

  18. YouTube Physics

    Science.gov (United States)

    Riendeau, Diane

    2012-09-01

    To date, this column has presented videos to show in class, Don Mathieson from Tulsa Community College suggested that YouTube could be used in another fashion. In Don's experience, his students are not always prepared for the mathematic rigor of his course. Even at the high school level, math can be a barrier for physics students. Walid Shihabi, a colleague of Don's, decided to compile a list of YouTube videos that his students could watch to relearn basic mathematics. I thought this sounded like a fantastic idea and a great service to the students. Walid graciously agreed to share his list and I have reproduced a large portion of it below.

  19. Neutron image intensifier tubes

    International Nuclear Information System (INIS)

    Verat, M.; Rougeot, H.; Driard, B.

    1983-01-01

    The most frequently used techniques in neutron radiography employ a neutron converter consisting of either a scintillator or a thin metal sheet. The radiation created by the neutrons exposes a photographic film that is in contact with the converter: in the direct method, the film is exposed during the time that the object is irradiated with neutrons; in the transfer method, the film is exposed after the irradiation of the object with neutrons. In industrial non-destructive testing, when many identical objects have to be checked, these techniques have several disadvantages. Non-destructive testing systems without these disadvantages can be constructed around neutron-image intensifier tubes. A description and the operating characteristics of neutron-image intensifier tubes are given. (Auth.)

  20. Tube coupling device

    Science.gov (United States)

    Myers, William N. (Inventor); Hein, Leopold A. (Inventor)

    1987-01-01

    A first annular ring of a tube coupling device has a keyed opening sized to fit around the nut region of a male coupling, and a second annular ring has a keyed opening sized to fit around the nut of a female coupling. Each ring has mating ratchet teeth and these rings are biased together, thereby engaging these teeth and preventing rotation of these rings. This in turn prevents the rotation of the male nut region with respect to the female nut. For tube-to-bulkhead locking, one facet of one ring is notched, and a pin is pressed into an opening in the bulkhead. This pin is sized to fit within one of the notches in the ring, thereby preventing rotation of this ring with respect to the bulkhead.

  1. PEG Tube Placement

    Directory of Open Access Journals (Sweden)

    Saptarshi Biswas

    2014-01-01

    Full Text Available Percutaneous endoscopic gastrostomy (PEG has been used for providing enteral access to patients who require long-term enteral nutrition for years. Although generally considered safe, PEG tube placement can be associated with many immediate and delayed complications. Buried bumper syndrome (BBS is one of the uncommon and late complications of percutaneous endoscopic gastrostomy (PEG placement. It occurs when the internal bumper of the PEG tube erodes into the gastric wall and lodges itself between the gastric wall and skin. This can lead to a variety of additional complications such as wound infection, peritonitis, and necrotizing fasciitis. We present here a case of buried bumper syndrome which caused extensive necrosis of the anterior abdominal wall.

  2. Incidental extracolonic findings on bright lumen MR colonography in a population at increased risk for colorectal carcinoma

    International Nuclear Information System (INIS)

    Yusuf, Erlangga; Florie, Jasper; Nio, Chung Yung; Jensch, Sebastian; Nievelstein, Rutger A.J.; Baak, Lubbertus; Stoker, Jaap

    2011-01-01

    Purpose: Incidental extracolonic findings affect patient treatment and cost. Therefore, to consider magnetic resonance colonography (MRC) as a tool for colorectal cancer and polyps screening, more knowledge is needed on extracolonic findings. In this study, we sought to determine the prevalence and the spectrum of extracolonic findings in patients with an increased risk colorectal cancer that underwent bright lumen MRC. Materials and methods: MRC examinations were performed in 210 patients. A gadolinium solution was administered rectally for distension of the colon. Extracolonic findings were scored by two radiologists and classified by using C-RADS Reporting System. All findings (with advice regarding work-up) were reported to the patient's physician and followed up for 4.5 years on average. Results: Extracolonic findings were found in 125 (59.5%) patients. Ten (4.8%) had 'potentially important' findings (C-RADS category E4). Twenty-five patients (11.9%) had 'likely unimportant' findings (E3), 90 (42.8%) had 'clinically unimportant' findings (E2) and 85 (40.5%) had a normal exam (E1). In 14 (6.7%) patients additional work-up was performed for their incidentally discovered lesions. In three of them surgery was performed. After work-up, only in two (1.0%) patients a malignancy was found. Conclusion: The number of new relevant extracolonic findings is small and the required additional work-up is limited. This should be considered for implementation of 'bright lumen' MRC as a screening tool.

  3. Molecular cloning and expression of cDNA encoding a lumenal calcium binding glycoprotein from sarcoplasmic reticulum

    International Nuclear Information System (INIS)

    Leberer, E.; Charuk, J.H.M.; MacLennan, D.H.; Green, N.M.

    1989-01-01

    Antibody screening was used to isolate a cDNA encoding the 160-kDa glycoprotein of rabbit skeletal muscle sarcoplasmic reticulum. The cDNA is identical to that encoding the 53-kDa glycoprotein except that it contains an in-frame insertion of 1,308 nucleotides near its 5' end, apparently resulting from alternative splicing. The protein encoded by the cDNA would contain a 19-residue NH 2 -terminal signal sequence and a 453-residue COOH-terminal sequence identical to the 53-kDa glycoprotein. It would also contain a 436-amino acid insert between these sequences. This insert would be highly acidic, suggesting that it might bind Ca 2+ . The purified 160-kDa glycoprotein and the glycoprotein expressed in COS-1 cells transfected with cDNA encoding the 160-kDa glycoprotein were shown to bind 45 C 2+ in a gel overlay assay. The protein was shown to be located in the lumen of the sarcoplasmic reticulum and to be associated through Ca 2+ with the membrane. The authors propose that this lumenal Ca 2+ binding glycoprotein of the sarcoplasmic reticulum be designated sarcalumenin

  4. Effects of cryopreservation on excretory function, cellular adhesion molecules and vessel lumen formation in human umbilical vein endothelial cells.

    Science.gov (United States)

    Cai, Guoping; Lai, Binbin; Hong, Huaxing; Lin, Peng; Chen, Weifu; Zhu, Zhong; Chen, Haixiao

    2017-07-01

    Cryopreservation is widely used in regenerative medicine for tissue preservation. In the present study, the effects of cryopreservation on excretory function, cellular adhesion molecules and vessel lumen formation in human umbilical vein endothelial cells (HUVECs) were investigated. After 0, 4, 8, 12 or 24 weeks of cryopreservation in liquid nitrogen, the HUVECs were thawed. The excretory functions markers (endothelin‑1, prostaglandin E1, von Willebrand factor and nitric oxide) of HUVECs were measured by ELISA assay. The expression of intercellular adhesion molecule‑1 (ICAM‑1) in HUVECs was analyzed using flow cytometry. An angiogenesis assay was used to determine the angiogeneic capabilities of the thawed HUVECs. The results demonstrated that cryopreserved/thawed and recultivated HUVECs were unsuitable for tissue‑engineered microvascular construction. Specifically, the excretory function of the cells was significantly decreased in the post‑cryopreserved HUVECs at 24 weeks. In addition, the level of ICAM‑1 in HUVECs was significantly upregulated from the fourth week of cryopreservation. Furthermore, the tube‑like structure‑forming potential was weakened with increasing cryopreservation duration, and the numbers of lumen and the length of the pipeline were decreased in the thawed HUVECs, in a time‑dependent manner. In conclusion, the results of the present study revealed that prolonged cryopreservation may lead to HUVEC dysfunction and did not create stable cell lines for tissue‑engineered microvascular construction.

  5. Recurrent inspection of tubes

    International Nuclear Information System (INIS)

    Andersson, S.

    1984-01-01

    Recommendations concerning the selection of areas for the inspection of tubes have been outlined. The aim is to focus the control on the regions which are important for the safety and where damage is supposed to take place. The number of zones will depend on the risk factors as judged by experts. The localizing will be based upon probable damaging mechanisms. A certain number of areas should be chosen at random. (G.B.)

  6. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  7. Cathode ray tube

    International Nuclear Information System (INIS)

    1979-01-01

    A cathode ray tube comprises two electron lens means in combination to crossover the electron beam at a second crossover between the two electron lens means with one of the two lens means having a variable voltage applied thereto to control the location of the beam crossover in order to focus the beam onto a display screen at any location away from the screen center. (Auth.)

  8. Fabrication of seamless calandria tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Phanibabu, C.; Bhaskara Rao, C.V.; Kalidas, R.; Ganguly, C.

    2002-01-01

    Full text: Calandria tube is a large diameter, thin walled zircaloy-4 tube and is an important structural component of PHWR type of reactors. These tubes are lifetime components and remain during the full life of the reactor. Calandria tubes are classified as extremely thin walled tubes with a diameter to wall thickness ratio of around 96. Such thin walled tubes are conventionally produced by seam welded route comprising of extrusion of slabs followed by a series of hot and rolling passes, shaping into O-shape and eventual welding. An alternative and superior method of fabricating the calandria tubes, the seamless route, has been developed, which involves hot extrusion of mother blanks followed by three successive cold pilger reductions. Eccentricity correction of the extruded blanks is carried out on a special purpose grinding equipment to bring the wall thickness variation within permissible limits. Predominant wall thickness reductions are given during cold pilgering to ensure high Q-factor values. The texture in the finished tubes could be closely, controlled with an average f r value of 0.65. Pilgering parameters and tube guiding system have been specially designed to facilities rolling of thin walled tubes. Seamless calandria tubes have distinct advantages over welded tubes. In addition to the absence of weld, they are dimensionally more stable, lighter in weight and possess uniform grains with superior grain size. The cycle time from billet to finished product is substantially reduced and the product is amenable to high level of quality assurance. The most significant feature of the seamless route is its material recovery over welded route. Residual stresses measured in the tubes indicate that these are negligible and uniform along the length of the tube. In view of their superior quality, the first charge of seamless calandria tubes will be rolled into the first 500 MWe Pressurised Heavy Water Reactor at Tarapur

  9. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  10. Measurements of local liquid velocity and interfacial parameters of air-water bubbly flows in a horizontal tube

    International Nuclear Information System (INIS)

    Yang Jian; Zhang Mingyuan; Zhang Chaojie; Su Yuliang

    2002-01-01

    Distribution of local kinematic parameters of air-water bubbly flows in a horizontal tube with an ID of 35 mm was investigated. The local liquid velocity was measured with a cylindrical hot film probe, and local void fraction, bubble frequency and bubble velocity were measured with a double-sensor probe. It was found that the axial liquid velocity has a same profile as that of single liquid phase flow in the lower part of the tube, and it suffers a sudden reduction in the upper part of the tube. With increasing airflow rate, the liquid velocity would increase in the lower part of the tube, and further decrease at the upper part of the tube, respectively. Most bubbles are congested at the upper part of the tube, and the void fraction and bubble frequencies have similar profile and both are asymmetrical with the tube axis with their maximum values located near the upper tube wall

  11. White organic light-emitting diodes with fluorescent tube efficiency.

    Science.gov (United States)

    Reineke, Sebastian; Lindner, Frank; Schwartz, Gregor; Seidler, Nico; Walzer, Karsten; Lüssem, Björn; Leo, Karl

    2009-05-14

    The development of white organic light-emitting diodes (OLEDs) holds great promise for the production of highly efficient large-area light sources. High internal quantum efficiencies for the conversion of electrical energy to light have been realized. Nevertheless, the overall device power efficiencies are still considerably below the 60-70 lumens per watt of fluorescent tubes, which is the current benchmark for novel light sources. Although some reports about highly power-efficient white OLEDs exist, details about structure and the measurement conditions of these structures have not been fully disclosed: the highest power efficiency reported in the scientific literature is 44 lm W(-1) (ref. 7). Here we report an improved OLED structure which reaches fluorescent tube efficiency. By combining a carefully chosen emitter layer with high-refractive-index substrates, and using a periodic outcoupling structure, we achieve a device power efficiency of 90 lm W(-1) at 1,000 candelas per square metre. This efficiency has the potential to be raised to 124 lm W(-1) if the light outcoupling can be further improved. Besides approaching internal quantum efficiency values of one, we have also focused on reducing energetic and ohmic losses that occur during electron-photon conversion. We anticipate that our results will be a starting point for further research, leading to white OLEDs having efficiencies beyond 100 lm W(-1). This could make white-light OLEDs, with their soft area light and high colour-rendering qualities, the light sources of choice for the future.

  12. Microdischarges in DC accelerator tubes

    International Nuclear Information System (INIS)

    Eastham, D.A.; Thorn, R.

    1978-07-01

    Voltage tests on the Daresbury ceramic/titanium accelerator tube have shown that microdischarges play an important role in the conditioning process. It has been found that the voltage onset for microdischarges in a tube is dependent on the surface contamination of the electrodes and the tube geometry (in particular the tube length). This geometrical effect can be related to the trajectories of secondary ions emitted from the electrode surfaces. Sensitive diagnostic techniques have been developed to study the mass and energy distribution of ions emitted along the axis of the tube during these predischarges. The energy distribution of protons (and H - ions) can be related to the origins of the discharges in the tube. Detailed results are presented for a particular tube geometry. (author)

  13. Small GTPase R-Ras participates in neural tube formation in zebrafish embryonic spinal cord.

    Science.gov (United States)

    Ohata, Shinya; Uga, Hideko; Okamoto, Hitoshi; Katada, Toshiaki

    2018-06-27

    Ras related (R-Ras), a small GTPase, is involved in the maintenance of apico-basal polarity in neuroepithelial cells of the zebrafish hindbrain, axonal collapse in cultured murine hippocampal neurons, and maturation of blood vessels in adult mice. However, the role of R-Ras in neural tube formation remains unknown. Using antisense morpholino oligonucleotides (AMOs), we found that in the spinal cord of zebrafish embryos, the lumen was formed bilaterally in rras morphants, whereas it was formed at the midline in control embryos. As AMO can cause off-target effects, we generated rras mutant zebrafish lines using CRISPR/Cas9 technology. Although these rras mutant embryos did not have a bilateral lumen in the spinal cord, the following findings suggest that the phenotype is unlikely due to an off-target effect of rras AMO: 1) The rras morphant phenotype was rescued by an injection of AMO-resistant rras mRNA, and 2) a bilaterally segregated spinal cord was not observed in rras mutant embryos injected with rras AMO. The results suggest that the function of other ras family genes may be redundant in rras mutants. Previous research reported a bilaterally formed lumen in the spinal cord of zebrafish embryos with a mutation in a planar cell polarity (PCP) gene, van gogh-like 2 (vangl2). In the present study, in cultured cells, R-Ras was co-immunoprecipitated with Vangl2 but not with another PCP regulator, Pricke1. Interestingly, the interaction between R-Ras and Vangl2 was stronger in guanine-nucleotide free point mutants of R-Ras than in wild-type or constitutively active (GTP-bound) forms of R-Ras. R-Ras may regulate neural tube formation in cooperation with Vangl2 in the developing zebrafish spinal cord. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Ultrasonic inspection of tube to tube plate welds

    International Nuclear Information System (INIS)

    Telford, D.W.; Peat, T.S.

    1985-01-01

    To monitor the deterioration of a weld between a tube and tube plate which has been repaired by a repair sleeve inside the tube and brazed at one end to the tube, ultrasound from a crystal at the end of a rod is launched, in the form of Lamb-type waves, into the tube through the braze and allowed to travel along the tube to the weld and be reflected back along the tube. The technique may also be used for the type of heat exchanger in which, during construction, the tubes are welded to the tube plate via external sleeves in which case the ultrasound is used in a similar manner to inspect the sleeve/tube plate weld. an electromagnetic transducer may be used to generate the ultrasound. The ultrasonic head comprising the crystal and an acoustic baffle is mounted on a Perspex (RTM) rod which may be rotated by a stepping motor. Echo signals from the region of deterioration may be isolated by use of a time gate in the receiver. The device primarily detects circumferentially orientated cracks, and may be used in heat exchangers in nuclear power plants. (author)

  15. Liquid-Nitrogen Test for Blocked Tubes

    Science.gov (United States)

    Wagner, W. R.

    1984-01-01

    Nondestructive test identifies obstructed tube in array of parallel tubes. Trickle of liquid nitrogen allowed to flow through tube array until array accumulates substantial formation of frost from moisture in air. Flow stopped and warm air introduced into inlet manifold to heat tubes in array. Tubes still frosted after others defrosted identified as obstructed tubes. Applications include inspection of flow systems having parallel legs.

  16. Double inflation

    International Nuclear Information System (INIS)

    Silk, J.; Turner, M.S.

    1986-04-01

    The Zel'dovich spectrum of adiabatic density perturbations is a generic prediction of inflation. There is increasing evidence that when the spectrum is normalized by observational data on small scales, there is not enough power on large scales to account for the observed large-scale structure in the Universe. Decoupling the spectrum on large and small scales could solve this problem. As a means of decoupling the large and small scales we propose double inflation (i.e., two episodes of inflation). In this scenario the spectrum on large scales is determined by the first episode of inflation and those on small scales by a second episode of inflation. We present three models for such a scenario. By nearly saturating the large angular-scale cosmic microwave anisotropy bound, we can easily account for the observed large-scale structure. We take the perturbations on small scales to be very large, deltarho/rho approx. = 0.1 to 0.01, which results in the production of primordial black holes (PBHs), early formation of structure, reionization of the Universe, and a rich array of astrophysical events. The Ω-problem is also addressed by our scenario. Allowing the density perturbations produced by the second episode of inflation to be large also lessens the fine-tuning required in the scalar potential and makes reheating much easier. We briefly speculate on the possibility that the second episode of inflation proceeds through the nucleation of bubbles, which today manifest themselves as empty bubbles whose surfaces are covered with galaxies. 37 refs., 1 fig

  17. Double Outlet Right Ventricle

    Science.gov (United States)

    ... Right Ventricle Menu Topics Topics FAQs Double Outlet Right Ventricle Double outlet right ventricle (DORV) is a rare form of congenital heart disease. En español Double outlet right ventricle (DORV) is a rare form of congenital ...

  18. A Novel Device for True Lumen Re-Entry After Subintimal Recanalization of Superficial Femoral Arteries: First-in-Man Experience and Technical Description

    International Nuclear Information System (INIS)

    Airoldi, Flavio; Faglia, Ezio; Losa, Sergio; Tavano, Davide; Latib, Azeem; Mantero, Manuela; Lanza, Gaetano; Clerici, Giacomo

    2011-01-01

    Subintimal angioplasty (SAP) is frequently performed for the treatment of critical limb ischemia (CLI) and has been recognized as an effective technique for these patients. Nevertheless, this approach is limited by the lack of controlled re-entry into the true lumen of the target vessel. We describe a novel device for true lumen re-entry after subintimal recanalization of superficial femoral arteries (SFA). We report our experience with six patients treated between April 2009 and January 2010 with a novel system designed to facilitate true lumen re-entry. The device was advanced by ipsilateral antegrade approach through a 6-French sheath. Successful reaccess into the true lumen was obtained in five of six patients without complications. The patient in whom the reaccess to the true lumen was not possible underwent successful bypass surgery. At 30 days follow-up, the SFA was patent in all patients according to echo-Doppler examination. Our preliminary experience indicates that this novel re-entry device increases the success rate of percutaneous revascularization of chronically occluded SFA.

  19. Multi objective optimization of foam-filled circular tubes for quasi-static and dynamic responses

    Directory of Open Access Journals (Sweden)

    Fauzan Djamaluddin

    Full Text Available AbstractFuel consumption and safety are currently key aspects in automobile design. The foam-filled thin-walled aluminium tube represents a potentially effective material for use in the automotive industry, due to its energy absorption capability and light weight. Multi-objective crashworthiness design optimization for foam-filled double cylindrical tubes is presented in this paper. The double structures are impacted by a rigid wall simulating quasi-static and dynamic loadings. The optimal parameters under consideration are the minimum peak crushing force and maximum specific energy absorption, using the non-dominated sorting genetic algorithm-II (NSGA-II technique. Radial basis functions (RBF and D-Optimal are adopted to determine the more complex crashworthiness functional objectives. The comparison is performed by finite element analysis of the impact crashworthiness characteristics in tubes under static and dynamic loads. Finally, the optimum crashworthiness performance of empty and foam-filled double tubes is investigated and compared to the traditional single foam-filled tube. The results indicate that the foam-filled double aluminium circular tube can be recommended for crashworthy structures.

  20. Tubing misconnections: normalization of deviance.

    Science.gov (United States)

    Simmons, Debora; Symes, Lene; Guenter, Peggi; Graves, Krisanne

    2011-06-01

    Accidental connection of an enteral system to an intravenous (IV) system frequently results in the death of the patient. Misconnections are commonly attributed to the presence of universal connectors found in the majority of patient care tubing systems. Universal connectors allow for tubing misconnections between physiologically incompatible systems. The purpose of this review of case studies of tubing misconnections and of current expert recommendations for safe tubing connections was to answer the following questions: In tubing connections that have the potential for misconnections between enteral and IV tubing, what are the threats to safety? What are patient outcomes following misconnections between enteral and IV tubing? What are the current recommendations for preventing misconnections between enteral and IV tubing? Following an extensive literature search and guided by 2 models of threats and errors, the authors analyzed case studies and expert opinions to identify technical, organizational, and human errors; patient-related threats; patient outcomes; and recommendations. A total of 116 case studies were found in 34 publications. Each involved misconnections of tubes carrying feedings, intended for enteral routes, to IV lines. Overwhelmingly, the recommendations were for redesign to eliminate universal connectors and prevent misconnections. Other recommendations were made, but the analysis indicates they would not prevent all misconnections. This review of the published case studies and current expert recommendations supports a redesign of connectors to ensure incompatibility between enteral and IV systems. Despite the cumulative evidence, little progress has been made to safeguard patients from tubing misconnections.

  1. Thermomechanical CSM analysis of a superheater tube in transient state

    Science.gov (United States)

    Taler, Dawid; Madejski, Paweł

    2011-12-01

    The paper presents a thermomechanical computational solid mechanics analysis (CSM) of a pipe "double omega", used in the steam superheaters in circulating fluidized bed (CFB) boilers. The complex cross-section shape of the "double omega" tubes requires more precise analysis in order to prevent from failure as a result of the excessive temperature and thermal stresses. The results have been obtained using the finite volume method for transient state of superheater. The calculation was carried out for the section of pipe made of low-alloy steel.

  2. Sealed ion accelerator tubes (survey)

    International Nuclear Information System (INIS)

    Voitsik, L.R.

    1985-01-01

    The first publications on developing commercial models of small-scale sealed accelerator tubes in which neutrons are generated appeared in the foreign press in 1954 to 1957; they were very brief and were advertising-oriented. The tubes were designed for neutron logging of oil wells instead of ampule neutron sources (Po + Be, Ra + Be). Later, instruments of this type began to be called neutron tubes from the resulting neutron radiation that they gave off. In Soviet Union a neutron tube was developed in 1958 in connection with the development of the pulsed neutron-neutron method of studying the geological profile of oil wells. At that time the tube developed was intended, in the view of its inventors, to replace standard isotope sources with constant neutron yield. A fairly detailed survey of neutron tubes was made in the studies. 8 refs., 8 figs

  3. Steam generator tube integrity program

    International Nuclear Information System (INIS)

    Dierks, D.R.; Shack, W.J.; Muscara, J.

    1996-01-01

    A new research program on steam generator tubing degradation is being sponsored by the U.S. Nuclear Regulatory Commission (NRC) at Argonne National Laboratory. This program is intended to support a performance-based steam generator tube integrity rule. Critical areas addressed by the program include evaluation of the processes used for the in-service inspection of steam generator tubes and recommendations for improving the reliability and accuracy of inspections; validation and improvement of correlations for evaluating integrity and leakage of degraded steam generator tubes, and validation and improvement of correlations and models for predicting degradation in steam generator tubes as aging occurs. The studies will focus on mill-annealed Alloy 600 tubing, however, tests will also be performed on replacement materials such as thermally-treated Alloy 600 or 690. An overview of the technical work planned for the program is given

  4. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    International Nuclear Information System (INIS)

    Iannicelli, Elsa; Di Renzo, Sara; Ferri, Mario; Pilozzi, Emanuela; Di Girolamo, Marco; Sapori, Alessandra; Ziparo, Vincenzo; David, Vincenzo

    2014-01-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting

  5. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  6. Computed tomography airway lumen volumetry in patients with acromegaly: Association with growth hormone levels and lung function.

    Science.gov (United States)

    Camilo, Gustavo Bittencourt; Carvalho, Alysson Roncally Silva; Guimarães, Alan Ranieri Medeiros; Kasuki, Leandro; Gadelha, Mônica Roberto; Mogami, Roberto; de Melo, Pedro Lopes; Lopes, Agnaldo José

    2017-10-01

    The segmentation and skeletonisation of images via computed tomography (CT) airway lumen volumetry provide a new perspective regarding the incorporation of this technique in medical practice. Our aim was to quantify morphological changes in the large airways of patients with acromegaly through CT and, secondarily, to correlate these findings with hormone levels and pulmonary function testing (PFT) parameters. This was a cross-sectional study in which 28 non-smoker patients with acromegaly and 15 control subjects underwent CT analysis of airway lumen volumetry with subsequent image segmentation and skeletonisation. Moreover, all participants were subjected to PFT. Compared with the controls, patients with acromegaly presented higher diameters in the trachea, right main bronchus and left main bronchus. The patients with acromegaly also showed a higher tracheal sinuosity index (the deviation of a line from the shortest path, calculated by dividing total length by shortest possible path) than the controls [1.06 (1.02-1.09) vs. 1.03 (1.02-1.04), P = 0.04], and tracheal stenosis was observed in 25% of these individuals. The tracheal area was correlated with the levels of growth hormone (r s  = 0.45, P = 0.02) and insulin-like growth factor type I (r s  = 0.38, P = 0.04). The ratio between the forced expiratory flow and forced inspiratory flow at 50% of the forced vital capacity was correlated with the tracheal area (r s  = 0.36, P = 0.02) and Δ tracheal diameters (r s  = 0.58, P volumetry, hormone levels and functional parameters of large airway obstruction. © 2017 The Royal Australian and New Zealand College of Radiologists.

  7. Segmentation of the lumen and media-adventitia boundaries of the common carotid artery from 3D ultrasound images

    Science.gov (United States)

    Ukwatta, E.; Awad, J.; Ward, A. D.; Samarabandu, J.; Krasinski, A.; Parraga, G.; Fenster, A.

    2011-03-01

    Three-dimensional ultrasound (3D US) vessel wall volume (VWV) measurements provide high measurement sensitivity and reproducibility for the monitoring and assessment of carotid atherosclerosis. In this paper, we describe a semiautomated approach based on the level set method to delineate the media-adventitia and lumen boundaries of the common carotid artery from 3D US images to support the computation of VWV. Due to the presence of plaque and US image artifacts, the carotid arteries are challenging to segment using image information alone. Our segmentation framework combines several image cues with domain knowledge and limited user interaction. Our method was evaluated with respect to manually outlined boundaries on 430 2D US images extracted from 3D US images of 30 patients who have carotid stenosis of 60% or more. The VWV given by our method differed from that given by manual segmentation by 6.7% +/- 5.0%. For the media-adventitia and lumen segmentations, respectively, our method yielded Dice coefficients of 95.2% +/- 1.6%, 94.3% +/- 2.6%, mean absolute distances of 0.3 +/- 0.1 mm, 0.2 +/- 0.1 mm, maximum absolute distances of 0.8 +/- 0.4 mm, 0.6 +/- 0.3 mm, and volume differences of 4.2% +/- 3.1%, 3.4% +/- 2.6%. The realization of a semi-automated segmentation method will accelerate the translation of 3D carotid US to clinical care for the rapid, non-invasive, and economical monitoring of atherosclerotic disease progression and regression during therapy.

  8. Is Nasobiliary Tube Really Safe A Case Report

    Directory of Open Access Journals (Sweden)

    Girolamo Geraci

    2011-05-01

    Full Text Available A case of esophageal ulcer caused by nasobiliary tube is described. This tool is not routinely considered to be a cause of major complications in the literature and to our knowledge, this is the first report of this kind of complication in nasobiliary tube placement. A 72-year-old patient presented with Charcot’s triad and was demonstrated to have cholangitis with multiple biliary stones in the common bile duct. Biliary drainage was achieved through endoscopic retrograde cholangiography, endoscopic sphincterotomy, biliary tree drainage and nasobiliary tube with double pigtail. The patient presented odynophagia, dysphagia and retrosternal pain 12 h after the procedure and upper endoscopy revealed a long esophageal ulcer, which was treated conservatively. This report provides corroboration of evidence that nasobiliary tubeplacement has potential complications related to pressure sores. In our opinion this is a possibility to consider in informed consent forms.

  9. Double hard scattering without double counting

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Markus [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Gaunt, Jonathan R. [VU Univ. Amsterdam (Netherlands). NIKHEF Theory Group; Schoenwald, Kay [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2017-02-15

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  10. Double hard scattering without double counting

    International Nuclear Information System (INIS)

    Diehl, Markus; Gaunt, Jonathan R.

    2017-02-01

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  11. Free compression tube. Applications

    Science.gov (United States)

    Rusu, Ioan

    2012-11-01

    During the flight of vehicles, their propulsion energy must overcome gravity, to ensure the displacement of air masses on vehicle trajectory, to cover both energy losses from the friction between a solid surface and the air and also the kinetic energy of reflected air masses due to the impact with the flying vehicle. The flight optimization by increasing speed and reducing fuel consumption has directed research in the aerodynamics field. The flying vehicles shapes obtained through studies in the wind tunnel provide the optimization of the impact with the air masses and the airflow along the vehicle. By energy balance studies for vehicles in flight, the author Ioan Rusu directed his research in reducing the energy lost at vehicle impact with air masses. In this respect as compared to classical solutions for building flight vehicles aerodynamic surfaces which reduce the impact and friction with air masses, Ioan Rusu has invented a device which he named free compression tube for rockets, registered with the State Office for Inventions and Trademarks of Romania, OSIM, deposit f 2011 0352. Mounted in front of flight vehicles it eliminates significantly the impact and friction of air masses with the vehicle solid. The air masses come into contact with the air inside the free compression tube and the air-solid friction is eliminated and replaced by air to air friction.

  12. Tube leak detector

    International Nuclear Information System (INIS)

    Morita, Bunji; Takamura, Koichi; Matsuda, Shigehiro; Kiyosawa, Shun-ichi; Asami, Toru; Yamada, Hiroshi; Naruse, Shin-ichi.

    1995-01-01

    The device of the present invention detects occurrence of leakage in a steam generator, a steam heating tube, or a heat exchanger of a nuclear power plant. Namely, an vibration sensor is disposed at the rear end of a rod-like supersonic resonance member. A node portion for the vibrations of the resonance member is held by a holding member and attached to a wall surface of a can such as a boiler. With such a constitution, the resonance member is resonated by supersonic waves generated upon leakage of the tube. The vibrations are measured by the vibration sensor at the rear end. Presence of leakage is detected by utilizing one or more of resonance frequencies. Since the device adopts a resonance phenomenon, a conduction efficiency of the vibrations is high, thereby enabling to detect leakage at high sensitivity. In addition, the supersonic wave resonance member has its top end directly protruded into a pressure vessel such as a boiler by using a metal or a ceramic which is excellent in heat and pressure resistance. Accordingly, the sound of leak can be detected efficiently. (I.S.)

  13. Shock tube Multiphase Experiments

    Science.gov (United States)

    Middlebrooks, John; Allen, Roy; Paudel, Manoj; Young, Calvin; Musick, Ben; McFarland, Jacob

    2017-11-01

    Shock driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching practical applications in engineering and science. The instability is present in high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase interface is impulsively accelerated by the passage of a shockwave. It is similar in development to the Richtmyer-Meshkov (RM) instability however, particle-to-gas coupling is the driving mechanism of the SDMI. As particle effects such as lag and phase change become more prominent, the SDMI's development begins to significantly deviate from the RM instability. We have developed an experiment for studying the SDMI in our shock tube facility. In our experiments, a multiphase interface is created using a laminar jet and flowed into the shock tube where it is accelerated by the passage of a planar shockwave. The interface development is captured using CCD cameras synchronized with planar laser illumination. This talk will give an overview of new experiments conducted to examine the development of a shocked cylindrical multiphase interface. The effects of Atwood number, particle size, and a second acceleration (reshock) of the interface will be discussed.

  14. Pressure tube reactors

    International Nuclear Information System (INIS)

    Natori, Hisahide.

    1981-01-01

    Purpose: To improve the electrical power generation efficiency in a pressure tube reactor in which coolants and moderators are separated by feedwater heating with heat generated in heavy water and by decreasing the amount of steams to be extracted from the turbine. Constitution: A heat exchanger and a heavy water cooler are additionally provided to a conventional pressure tube reactor. The heat exchanger is disposed at the pre-stage of a low pressure feedwater heater series. High temperature heavy water heated in the core is passed through the primary side of the exchanger, while feedwater is passed through the secondary side. The cooler is disposed on the downstream of the heat exchanger in the flowing direction of the heavy water, in which heavy water from the heat exchanger is passed through the primary side and the auxiliary equipment cooling water is sent to the secondary side thereof. Accordingly, since extraction of heating steams is no more necessary, the steam can be used for the rotation of the turbine, and the electrical power generation efficiency can be improved. (Seki, T.)

  15. Measurements of electrically exploded tubes

    International Nuclear Information System (INIS)

    Shearer, J.W.; Hartman, C.W.; Munger, R.H.; Gullickson, R.L.; Trimble, D.O.; Cheng, D.Y.

    1975-01-01

    The dynamics of electrically exploded tubes were investigated, principally by means of current measurements and flash x-ray pictures. The pinch effect was observed on the tube motion. Pileup of the imploding tube metal was seen on axis. An approximate analytical model can be roughly fitted to the data, but a more complete fit can be obtained with detailed numerical codes. Application of the results to the planning of future gas-embedded Z-pinch experiments is discussed. (U.S.)

  16. ETS transcription factor ELF5 induces lumen formation in a 3D model of mammary morphogenesis and its expression is inhibited by Jak2 inhibitor TG101348.

    Science.gov (United States)

    Chean, Jennifer; Chen, Charng-Jui; Shively, John E

    2017-10-01

    The loss of expression of a single gene can revert normal tissue to a malignant phenotype. For example, while normal breast has high lumenal expression of CEACAM1, the majority of breast cancers exhibit the early loss of this gene with the concurrent loss of their lumenal phenotype. MCF7 cells that lack CEACAM1 expression and fail to form lumena in 3D culture, regain the normal phenotype when transfected with CEACAM1. In order to probe the mechanism of this gain of function, we treated these cells with the clinically relevant Jak2 inhibitor TG101348 (TG), expecting that disruption of the prolactin receptor signaling pathway would interfere with the positive effects of transfection of MCF7 cells with CEACAM1. Indeed, lumen formation was inhibited, resulting in the down regulation of a set of genes, likely involved in the complex process of lumen formation. As expected, inhibition of the expression of many of these genes also inhibited lumen formation, confirming their involvement in a single pathway. Among the genes identified by the inhibition assay, ETS transcription factor ELF5 stood out, since it has been identified as a master regulator of mammary morphogenesis, and is associated with prolactin receptor signaling. When ELF5 was transfected into the parental MCF7 cells that lack CEACAM1, lumen formation was restored, indicating that ELF5 can replace CEACAM1 in this model system of lumenogenesis. We conclude that the event(s) that led to the loss of expression of CEACAM1 is epistatic in that multiple genes associated with a critical pathway were affected, but that restoration of the normal phenotype can be achieved with reactivation of certain genes at various nodal points in tissue morphogenesis. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Failure analysis of boiler tube

    International Nuclear Information System (INIS)

    Mehmood, K.; Siddiqui, A.R.

    2007-01-01

    Boiler tubes are energy conversion components where heat energy is used to convert water into high pressure superheated steam, which is then delivered to a turbine for electric power generation in thermal power plants or to run plant and machineries in a process or manufacturing industry. It was reported that one of the tubes of a fire-tube boiler used in a local industry had leakage after the formation of pits at the external surface of the tube. The inner side of the fire tube was working with hot flue gasses with a pressure of 10 Kg/cm/sup 2/ and temperature 225 degree C. The outside of the tube was surrounded by feed water. The purpose of this study was to determine the cause of pits developed at the external surface of the failed boiler tube sample. In the present work boiler tube samples of steel grade ASTM AI61/ASTM A192 were analyzed using metallographic analysis, chemical analysis, and mechanical testing. It was concluded that the appearance of defects on the boiler tube sample indicates cavitation type corrosion failure. Cavitation damage superficially resembled pitting, but surface appeared considerably rougher and had many closely spaced pits. (author)

  18. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  19. YouTube and 'psychiatry'.

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-12-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of 'psychiatry' during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of 'psychiatry' on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed.

  20. Bacterial Biofilms in Jones Tubes.

    Science.gov (United States)

    Ahn, Eric S; Hauck, Matthew J; Kirk Harris, Jonathan; Robertson, Charles E; Dailey, Roger A

    To investigate the presence and microbiology of bacterial biofilms on Jones tubes (JTs) by direct visualization with scanning electron microscopy and polymerase chain reaction (PCR) of representative JTs, and to correlate these findings with inflammation and/or infection related to the JT. In this study, prospective case series were performed. JTs were recovered from consecutive patients presenting to clinic for routine cleaning or recurrent irritation/infection. Four tubes were processed for scanning electron microscopy alone to visualize evidence of biofilms. Two tubes underwent PCR alone for bacterial quantification. One tube was divided in half and sent for scanning electron microscopy and PCR. Symptoms related to the JTs were recorded at the time of recovery. Seven tubes were obtained. Five underwent SEM, and 3 out of 5 showed evidence of biofilms (60%). Two of the 3 biofilms demonstrated cocci and the third revealed rods. Three tubes underwent PCR. The predominant bacteria identified were Pseudomonadales (39%), Pseudomonas (16%), and Staphylococcus (14%). Three of the 7 patients (43%) reported irritation and discharge at presentation. Two symptomatic patients, whose tubes were imaged only, revealed biofilms. The third symptomatic patient's tube underwent PCR only, showing predominantly Staphylococcus (56%) and Haemophilus (36%) species. Two of the 4 asymptomatic patients also showed biofilms. All symptomatic patients improved rapidly after tube exchange and steroid antibiotic drops. Bacterial biofilms were variably present on JTs, and did not always correlate with patients' symptoms. Nevertheless, routine JT cleaning is recommended to treat and possibly prevent inflammation caused by biofilms.

  1. Grooved tube plug rolls in

    International Nuclear Information System (INIS)

    Krausser, P.

    1991-01-01

    The removable plugs used to date by the Power Generation Group (KWU) of Siemens to seal defective steam generator tubes have a good track record. Their sealing principle is based on the elastic tensioning of three seal disks against the inside wall of the tube. Now a further removable plug is available -a roll-in plug with a metal-coated surface. It is particularly suitable for use in the roller-expanded zone of the tubes at the tube sheet. The plugs can be used in both Siemens-KWU steam generators and in steam generators manufactured in compliance with the guidelines of the ASME Code. (author)

  2. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  3. A novel Hsp70 of the yeast ER lumen is required for the efficient translocation of a number of protein precursors.

    OpenAIRE

    Craven, R A; Egerton, M; Stirling, C J

    1996-01-01

    The yeast genome sequencing project predicts an open reading frame (YKL073) that would encode a novel member of the Hsp70 family of molecular chaperones. We report that this 881 codon reading frame represents a functional gene expressing a 113-119 kDa glycoprotein localized within the lumen of the endoplasmic reticulum (ER). We therefore propose to designate this gene LHS1 (Lumenal Hsp Seventy). Our studies indicate that LHS1 is regulated by the unfolded protein response pathway, as evidenced...

  4. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  5. Jose Cabrera (Zorita) tube examination

    International Nuclear Information System (INIS)

    Kuchirka, P.J.

    1986-01-01

    Jose Cabrera (Zorita) tube examination procedures are discussed. This plant continues to use phosphate water chemistry (sodium/phosphate ratio = 2.1). Three hot leg tube segments were pulled from the Jose Cabera (Zorita) plant in 1985. One tube had a field EC indication on the OD at the first tube support plate and the other two had field EC indications on their ID about 3 inches above the bottom of the tube sheet. All three tubes were initially sent to Battelle for preliminary NDE and decontamination. Segments of two tubes were sent to Westinghouse for destructive examination. The results of the laboratory eddy current and radiographic examinations are given. The results of the visual examinations are also given. The tube with OD indications was destructively examined and shallow intergranular pitting and intergranular attack, up to 2 mils deep, were found on the OD in the tube sheet region. Local areas of IGA, up to 5 mils deep, were found on the OD within the tube support plate region. A summary of this information together with supporting micrographs is given. It was hypothesized that a caustic crevice environment was the cause of this mild degradation. Shallow areas of thinning or wastage, up to 3 mils, were found just above the top of the tube sheet in the sludge pile region. Even more shallow wastage was found at the edges of support plate locations. This wastage is believed to be the remnant of early plant chemistry when a higher sodium/phosphate ratio and higher phosphate concentration were allowed

  6. Tube for irradiation equipment

    International Nuclear Information System (INIS)

    Goehrich, K.; Vogt, H.

    1979-01-01

    This patent describes a tube for irradiation equipment for limiting an emergent beam, with a baseplate, possessing a central aperture, intended for attaching to the equipment, as well as four carrier plates, each of which possesses a limiting edge and a sliding edge located at right angles thereto. The carrier plates are located parallel to the baseplate, the limiting edge of each carrier plate resting against the sliding edge of the adjacent carrier plate and each of the two mutually opposite pairs of carrier plates being displaceable, parallel to the direction of its sliding edges and symmetrically to the center of the transmission aperture, for the purpose of continuously varying the transmission aperture defined by the limiting edges, during which displacement each of the displaced carrier plates carries with it the carrier plate, resting against the limiting edge of the former plate, parallel to the direction of the limiting edge of the latter plate. 8 claims

  7. Primary Fallopian Tube Carcinoma

    Directory of Open Access Journals (Sweden)

    Prasad K Shetty

    2011-01-01

    Full Text Available Primary Fallopian Tube Carcinoma (PFTC is rare and accounts for about 0.3% of all gynecologic cancers. Less than 1500 cases have been reported in the literature. It arises in postmenopausal women and typically presents with abdominal pelvic pain, vaginal bleeding and watery discharge. However, a correct diagnosis is rarely achieved preoperative, and in many cases, the diagnosis is made after incidental surgery for unrelated conditions commonly being ovarian carcinoma . Compared with ovarian carcinoma, PFTC more often presents at early stages, but it has a worse prognosis. PFTC is usually managed in the same manner as ovarian cancer. We report a case of Left PFTC that presented as Left ovarian mass, and we briefly review the literature.

  8. Pressure tube reactor

    International Nuclear Information System (INIS)

    Matsumoto, Tomoyuki; Fujino, Michihira.

    1980-01-01

    Purpose: To equalize heavy water flow distribution by providing a nozzle for externally injecting heavy water from a vibration preventive plate to the upper portion to feed the heavy water in a pressure tube reactor and swallowing up heavy water in a calandria tank to supply the heavy water to the reactor core above the vibration preventive plate. Constitution: A moderator injection nozzle is mounted on the inner wall of a calandria tank. Heavy water is externally injected above the vibration preventive plate, and heavy water in the calandria tank is swallowed up to supply the heavy water to the core reactor above the vibration preventive plate. Therefore, the heavy water flow distribution can be equalized over the entire reactor core, and the distribution of neutron absorber dissolved in the heavy water is equalized. (Yoshihara, H.)

  9. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-12-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at the point where sound is perceived to have maximum loudness, or at the point where the amplitude of the standing wave has maximum value, namely an antinode. An antinode coincides with the position of the tuning fork, beyond the end of the air column, which consequently introduces an end correction. One way to minimize this end correction is to measure the distance between consecutive antinodes.

  10. Integrated straight - through automatic non-destructive examination and data acquisition system for thin-wall tubes

    International Nuclear Information System (INIS)

    Stoessel, A.; Boulanger, G.; Furlan, J.; Mogavero, R.

    1981-09-01

    This non-destructive testing unit inspects the cladding tubes for the SUPER-PHENIX fast neutron reactor. The quality level demanded for these tubes, as well as their number, required designing an installation that combined high performance with a great testing rate and complete automation. The testing is effected under immersion by means of six transducers, focused in line, working at 30 MHz. The tubes are numbered on an automatic rig; marking is by dark rings obtained by superficial electrolysis of the tube and regularly distributed on the abscissa; the quality of the tube is not affected by this. The advantage of this numbering system is that it enables the tubes to be fed to the test set in any order. An acquisition unit, constituted of a microprocessor, a semi-graphical printer and a double floppy disk unit, makes it possible to enter, edit and store the information for each tube [fr

  11. Maximum utilization of primary reformer catalyst tubes careful assessment of remaining life-An experience at an ammonia plant

    International Nuclear Information System (INIS)

    Malik, M.A.

    2005-01-01

    Condition evaluation and residual life assessment of Reformer Catalyst Tubes has always been a point of concern for Ammonia and Methanol Plant operators. Failure of catalyst tubes results in total plant shutdown and consequent production loss. On the other hand, replacement of these tubes entails major cost impact on the company's budget, being a capital expenditure. A careful Residual Life Assessment of the tubes is therefore of utmost importance for maximum utilization of these tubes without jeopardizing plant operational reliability. This paper presents an experience of extracting maximum service life from the catalyst tubes of Primary Reformer of an Ammonia Plant. Fauji Fertilizer Company (FFC) has been operating the plant since 1982, having a designed capacity of 1100 MTPD. Its Primary Reformer has 288 catalyst tubes of IN-519 material (24Cr-24Ni-Nb). The design temperature and pressures are 925 degree C and 38kg/Cm respectively. Thanks to the optimum operating conditions, regular inspections and careful assessment of the residual life, the tubes have achieved more than double of the designed life and are still operating reliably. To evaluate the tube's health, Ultrasonic Inspection (UT) was carried out in 1987 and 1994 using attenuation technique. The tubes with maximum attenuation were marked for further evaluation. Accelerated Creep Rupture Test was carried out on sample tubes periodically (1996, 2001 and 2004). Tubes were selected on the basis of UT results, TMT (Tube Metal Temperature) monitoring and Inspection findings. Based on the combined results of DT, NDT, equipment history and foreseen operational parameters, the life of these tubes was carefully assessed periodically. The tubes have been in service for more than 23 years (design life: 11 years) and a further life of 04 years has been predicted as per last assessment.The experience of successful health evaluation and residual life assessment has saved substantial cost involved in tubes replacement

  12. Tube pancreatico-duodenostomy for management of a severe penetrating pancreaticoduodenal injury.

    Science.gov (United States)

    Hatzigeorgiadis, Anestis; Boulas, Konstantinos A; Barettas, Nikolaos; Papageorgiou, Irene; Blouhos, Konstantinos

    2014-05-27

    Optimal management of penetrating pancreaticoduodenal injuries and better outcomes are associated with simple, fast damage control surgery and shorter operative time. The performance of pyloric exclusion and tube duodenostomy has markedly decreased. However, there is still a trend toward their performance in cases of delay duodenal repair or severe pancreaticoduodenal injury. The present report describes a case of a hemodynamically stable patient with a single penetrating gunshot trauma causing an AAST-OIS grade III pancreatic head injury and grade IV injury of the second portion of the duodenum. The patient was treated in our Level IV rural trauma center and submitted to primary closure of the posterolateral duodenal wall (the laceration of the contralateral inner medial duodenal wall could not be repaired), external duodenal and pancreatic drainage, and duodenal decompression by tube pancreatico-duodenostomy (insertion of a 18 Fr Foley catheter through the laceration of the pancreatic head toward the duodenal lumen), tube cholangiostomy, and pyloric exclusion accompanied with a feeding jejunostomy. Tube pancreatico-duodenostomy, which is described for the first time in the literature, turned out to be effective and can be considered as an option in pancreaticoduodenal trauma when the inner medial duodenal wall cannot be repaired.

  13. White thrombus formation in blood tubing lines in a chronic hemodialysis unit.

    Science.gov (United States)

    Watnick, Suzanne; Stooksbury, Michael; Winter, Rolf; Riscoe, Michael; Cohen, David M

    2008-03-01

    Previous reports have described white particulate matter in banked blood components, but no prior public reports describe such matter in blood tubing during the course of routine in-center hemodialysis. This report describes the events, investigations, and preliminary conclusions associated with the spontaneous formation of adherent white thrombus in the venous and arterial blood lines during routine in-center hemodialysis treatments. Design setting, participants, & measurements: This investigation occurred at the Portland Veterans Administration Medical Center (PVAMC) Hemodialysis Unit from October 2006 through April 2007. Sixty-eight variables regarding demographics, medical history and dialysis treatments were collected on our 34 chronic hemodialysis outpatients. Over a 5-wk interval, 62% (21 of 34) of the chronic hemodialysis patients unexpectedly developed a white precipitate adhering to the lumenal surface of their dialysis blood tubing, with 73 of 580 chronic dialysis treatments exhibiting the phenomenon. Microscopic and biochemical analyses were consistent with white thrombus, formed by an aggregation of platelets and fibrin. An alert was issued and other in-center hemodialysis units noted similar findings. This was remedied by the removal of specific tubing. Both patient-specific and tubing-specific factors may have been operative. Although patient safety was not adversely affected, assessment of clinical and manufacturing variables potentially affecting platelet activation is warranted.

  14. Radiographic findings of post-operative double stapled trans anal rectal resection (STARR) in patient with obstructed defecation syndrome (ODS).

    Science.gov (United States)

    Grassi, Roberto; Romano, Stefania; Micera, Osvaldo; Fioroni, Claudio; Boller, Brigitta

    2005-03-01

    Longo's procedure of double stapled trans anal rectal resection (STARR) has been evocated as surgical treatment of the obstructed defecation syndrome (ODS) in patients with rectal mucosal prolapse. The aim of this study was to investigate the post-interventional findings of this technique, to help radiologist in knowledge of the changed morphology of the rectal lumen, also in attempt to recognize some potential related complications.

  15. Improper tube fixation causing a leaky cuff

    Directory of Open Access Journals (Sweden)

    Gupta Babita

    2010-01-01

    Full Text Available Leaking endotracheal tube cuffs are common problems in intensive care units. We report a case wherein the inflation tube was damaged by the adhesive plaster used for tube fixation and resulted in leaking endotracheal tube cuff. We also give some suggestions regarding the tube fixation and some remedial measures for damaged inflation system.

  16. Characterization of tube support alloys

    International Nuclear Information System (INIS)

    Vaia, A.R.

    1985-01-01

    The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions

  17. Radioisotope study of Eustachian tube

    International Nuclear Information System (INIS)

    De Rossi, G.; Campioni, P.; Vaccaro, A.

    1988-01-01

    Radioisotope studies of Eustachian tube are suggested in the preoperative phase of tympanoplasty, in order to assess tubal drainage and secretion. The use of gamma camera fitted to a computer allowed the AA, to calculate some semi-quantitative parameters for an exact assessment of the radioactivity transit from the tympanic cass up to the pharyngeal cavity, throughout the Eustachian tube. (orig.) [de

  18. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence ... is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this ...

  19. Tubing Cutter is Activated Hydraulically

    Science.gov (United States)

    Mcsmith, D. G.; Richardson, J. I.

    1983-01-01

    Hydraulically-actuated tubing cutter severs tubing when operator squeezes handle grip. "Gooseneck" extension enables cutter to be used in areas where accessiblity is limited. Cutter has potential as flight-line tool and is useful in automobile and fire rescue work.

  20. Flaming on YouTube

    NARCIS (Netherlands)

    Moor, Peter J.; Heuvelman, A.; Verleur, R.

    2010-01-01

    In this explorative study, flaming on YouTube was studied using surveys of YouTube users. Flaming is defined as displaying hostility by insulting, swearing or using otherwise offensive language. Three general conclusions were drawn. First, although many users said that they themselves do not flame,

  1. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia NEI Home Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  2. Flowmeter with silicon flow tube

    NARCIS (Netherlands)

    Lammerink, Theodorus S.J.; Dijkstra, Marcel; Haneveld, J.; Lötters, Joost Conrad

    2009-01-01

    A flowmeter comprising a system chip with a silicon substrate provided on a carrier, in an opening whereof at least one silicon flow tube is provided for transporting a medium whose flow rate is to be measured, said tube having two ends that issue via a wall of the opening into channels coated with

  3. Improved guide tube bulge tool

    International Nuclear Information System (INIS)

    Vaill, R.E.; Phillips, W.D.

    1979-01-01

    A guide tube bulge tool for securing control rod guide tubes to a fuel assembly grid, includes a cylinder having several flexible tines each of which is equipped with a semispherical radially outwardly extending projection. A tapered ram fits into the cylinder so as to force the tines outwardly when the ram is pulled into the cylinder while supporting the other tines. (UK)

  4. Tracking with Straw Tubes in the PANDA Experiment

    Directory of Open Access Journals (Sweden)

    Bragadireanu M.

    2014-03-01

    Full Text Available The PANDA spectrometer will be built at the FAIR facility at Darmstadt (Germany to perform accurate tests of the strong interaction through ¯pp and ¯pA annihilation studies. The charged particle tracking at PANDA will be done using both solid state and gaseous detectors. Among the latter, two straw tube detector systems will be built [1]. The cylindrical, central straw tube tracker features a high spatial and momentum resolution for a wide range of particle momenta from about 8 GeV/c down to a few 100 MeV/c, together with particle identification in the momentum region below about 1 GeV/c by measuring the specific energy-loss. A new technique, based on self-supporting straw double layers with intrinsic wire tension developed for the COSY-TOF straw tracker [2], has been adopted for the PANDA trackers. The development of the readout electronics for the straw tubes is ongoing. Prototypes have been produced and used to instrument straw tube modules that have been tested with cosmic rays and proton beams. Design issues of the PANDA straw tubes, together with the results of the prototype tests are presented.

  5. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  6. CALiPER Report 20.4: Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-30

    This CALiPER report focuses on lumen maintenance, chromaticity maintenance, and catastrophic failure in 32 of the Series 20 LED PAR38 lamps and 8 benchmark lamps, which were monitored for nearly 14,000 hours at ambient temperatures between 44°C and 45°C.

  7. Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus-eluting bioresorbable polylactide scaffold in comparison with the cobalt-chromium metallic stent?

    NARCIS (Netherlands)

    Sotomi, Yohei; Onuma, Yoshinobu; Miyazaki, Yosuke; Asano, Taku; Katagiri, Yuki; Tenekecioglu, Erhan; Jonker, Hans; Dijkstra, Jouke; de Winter, Robbert J.; Wykrzykowska, Joanna J.; Stone, Gregg W.; Popma, Jeffrey J.; Kozuma, Ken; Tanabe, Kengo; Serruys, Patrick W.; Kimura, Takeshi

    2017-01-01

    Aims: Immediately after stent/scaffold implantation, quantitative coronary angiography (QCA) in comparison to optical coherence tomography (OCT) more severely underestimates the lumen diameter (LD) in Absorb than in XIENCE. This OCT-QCA discrepancy has not been evaluated at long-term follow-up. The

  8. Intracoronary stent implantation: new approach using a monorail system and new large-lumen 7F catheters from the brachial route.

    Science.gov (United States)

    Jenny, D B; Robert, G P; Fajadet, J C; Cassagneau, B G; Marco, J

    1992-04-01

    In this brief report we describe a case of successful multivessel PTCA with intracoronary stent implantation using a new large-lumen 7F catheter from the left brachial approach. The application of this technique should be considered for intravascular stent implantation when anticoagulation ideally should not be interrupted or in anatomical situations limiting femoral vascular access.

  9. Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin

    International Nuclear Information System (INIS)

    Dong, Nana; Xie, Zulong; Wang, Wei; Dai, Jiannan; Sun, Meng; Pu, Zhongyue; Tian, Jinwei; Yu, Bo

    2016-01-01

    Coronary angiography (CAG) is widely used to assess lumen dimensions, and optical coherence tomography (OCT) is used to evaluate the characteristics of atherosclerotic plaque. This study was aimed to compare coronary lumen dimensions using CAG and plaque characteristics using OCT and their changes during statin therapy. We identified 97 lipid-rich plaques from 69 statin-naïve patients, who received statin therapy in the following 12 months. CAG and OCT examinations were conducted at baseline and 12-month follow-up period. Lesion length, as measured by CAG, was closely correlated with lipid length by OCT (baseline: r = 0.754, p < 0.001; follow-up: r = 0.639, p < 0.001). However, no significant correlations were found between the other findings on OCT and data on CAG. With 12-month statin therapy, microstructures of lipid-rich plaques were significantly improved, but CAG-derived lumen dimensions were not improved. Moreover, we found no significant relationship between changes in OCT measurements and changes in CAG data over time. Lipid length on OCT and lesion length on CAG were closely correlated. However, plaque microstructural characteristics on OCT showed no significantly statistically correlations with lumen dimensions on CAG, neither did their evolutionary changes induced by statin over time. Clinical trial registry: ClinicalTrial.gov. Registered number: NCT01023607. Registered 1 December 2009

  10. Protection of thylakoids against combined light and drought by a lumenal substance in the resurrection plant Haberlea rhodopensis

    Science.gov (United States)

    Georgieva, Katya; Sárvári, Éva; Keresztes, Áron

    2010-01-01

    Background and Aims Haberlea rhodopensis is a perennial, herbaceous, saxicolous, poikilohydric flowering plant that is able to survive desiccation to air-dried state under irradiance below 30 µmol m−2 s−1. However, desiccation at irradiance of 350 µmol m−2 s−1 induced irreversible changes in the photosynthetic apparatus, and mature leaves did not recover after rehydration. The aim here was to establish the causes and mechanisms of irreversible damage of the photosynthetic apparatus due to dehydration at high irradiance, and to elucidate the mechanisms determining recovery. Methods Changes in chloroplast structure, CO2 assimilation, chlorophyll fluorescence parameters, fluorescence imaging and the polypeptide patterns during desiccation of Haberlea under medium (100 µmol m−2 s−1; ML) irradiance were compared with those under low (30 µmol m−2 s−1; LL) irradiance. Key Results Well-watered plants (control) at 100 µmol m−2 s−1 were not damaged. Plants desiccated at LL or ML had similar rates of water loss. Dehydration at ML decreased the quantum efficiency of photosystem II photochemistry, and particularly the CO2 assimilation rate, more rapidly than at LL. Dehydration induced accumulation of stress proteins in leaves under both LL and ML. Photosynthetic activity and polypeptide composition were completely restored in LL plants after 1 week of rehydration, but changes persisted under ML conditions. Electron microscopy of structural changes in the chloroplast showed that the thylakoid lumen is filled with an electron-dense substance (dense luminal substance, DLS), while the thylakoid membranes are lightly stained. Upon dehydration and rehydration the DLS thinned and disappeared, the time course largely depending on the illumination: whereas DLS persisted during desiccation and started to disappear during late recovery under LL, it disappeared from the onset of dehydration and later was completely lost under ML. Conclusions Accumulation of DLS

  11. The lumenal loop M672-P707 of the Menkes protein (ATP7A) transfers copper to peptidylglycine monooxygenase

    Energy Technology Data Exchange (ETDEWEB)

    Otoikhian, Adenike [Oregon Health & Sciences University; Barry, Amanda N. [Los Alamos National Laboratory; Mayfield, Mary [Oregon Health & Science University; Nilges, Mark [Illinois EPR Center; Huang, Yiping [Johns Hopkins University; Lutsenko, Svetlana [Johns Hopkins University; Blackburn, Ninian [Oregon Health & Science University

    2012-05-14

    Copper transfer to cuproproteins located in vesicular compartments of the secretory pathway depends on activity of the copper translocating ATPase (ATP7A or ATP7B) but the mechanism of transfer is largely unexplored. Copper-ATPase ATP7A is unique in having a sequence rich in histidine and methionine residues located on the lumenal side of the membrane. The corresponding fragment binds Cu(I) when expressed as a chimera with a scaffold protein, and mutations or deletions of His and/or Met residues in its sequence inhibit dephosphorylation of the ATPase, a catalytic step associated with copper release. Here we present evidence for a potential role of this lumenal region of ATP7A in copper transfer to cuproenzymes. Both Cu(II) and Cu(I) forms were investigated since the form in which copper is transferred to acceptor proteins is currently unknown. Analysis of Cu(II) using EPR demonstrated that at Cu:P ratios below 1:1, 15N-substituted protein had Cu(II) bound by 4 His residues, but this coordination changed as the Cu(II) to protein ratio increased towards 2:1. XAS confirmed this coordination via analysis of the intensity of outer-shell scattering from imidazole residues. The Cu(II) complexes could be reduced to their Cu(I) counterparts by ascorbate, but here again, as shown by EXAFS and XANES spectroscopy, the coordination was dependent on copper loading. At low copper Cu(I) was bound by a mixed ligand set of His + Met while at higher ratios His coordination predominated. The copper-loaded loop was able to transfer either Cu(II) or Cu(I) to peptidylglycine monooxygenase in the presence of chelating resin, generating catalytically active enzyme in a process that appeared to involve direct interaction between the two partners. The variation of coordination with copper loading suggests copper-dependent conformational change which in turn could act as a signal for regulating copper release by the ATPase pump.

  12. Optimization of the Darrieus wind turbines with double-multiple-streamtube model

    International Nuclear Information System (INIS)

    Paraschivoiu, I.

    1985-01-01

    This paper discusses a new improvement of the double-multiple-stream tube model by considering the stream tube expansion effects on the Darrieus wind turbine. These effects, allowing a more realistic modeling of the upwind/downwind flow field asymmetries inherent in the Darrieus rotor, were calculated by using CARDAAX computer code. When the dynamic stall is introduced in the double-multiple-stream tube model, the aerodynamic loads and performance show significant changes in the range of low tip-speed ratio

  13. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  14. Conditioning and breakdown phenomena in accelerator tubes

    International Nuclear Information System (INIS)

    Skorka, S.J.

    1979-01-01

    Important breakdown mechanisms in accelerator tubes are reviewed, and discharge phenomena in NEC tubes are deduced from the surface appearance of the electrodes and insulators of a used tube. Microphotos of these surfaces are shown

  15. Tensile strength of Zr-2.5 Nb pressure tubes: A statistical study

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Priti Kotak, E-mail: pritik@barc.gov.in [Senior Scientist, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Dubey, J.S.; Datta, D.; Shriwastaw, R.S.; Rath, B.N.; Singh, R.N. [Senior Scientist, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Anantharaman, S. [Head, Post Irradiation Examination Division, Bhabha Atomic Research Centre, Mumbai (India); Chakravartty, J.K. [Director, Materials Group, Bhabha Atomic Research Centre, Mumbai (India)

    2015-12-15

    Highlights: • Tensile properties in axial and transverse direction for a number of Indian Zr-2.5 Nb PHWR pressure tubes. • Distribution of tensile properties of double-melted and quadruple-melted pressure tubes. • Tensile properties at front-end and back-end of the quadruple melted pressure tubes at room temperature and at 300 °C. - Abstract: In order to get an idea of the statistical variation in the tensile properties of the double-melted as well as quadruple melted Zr-2.5 Nb pressure tubes (PTs) and also the variation in tensile properties between the two ends of the pressure tubes, tension tests were carried out on around 50 pressure tube off-cuts. Longitudinal and transverse tensile specimens were prepared from these off-cuts of pressure tubes of double-melted and quadruple melted types. For quadruple melted pressure tubes the specimens were tested from both front-end and back-end off-cuts. Miniature flat tensile specimens having 1.8 mm width and 1.5 mm thickness and 7.6 mm gauge length were prepared from the pressure tube off-cuts without any flattening treatment. Tension tests were carried out in a screw-driven machine at room temperature and 300 °C for both front-end and back-end off-cuts of each of 16 pressure tubes. In general the transverse specimens showed higher yield strength (YS) and ultimate tensile strength (UTS) compared to the longitudinal specimens. Transverse specimens showed less strain hardening compared to the longitudinal specimens. The axial specimens showed higher uniform (UE) and total elongation (TE) compared to the transverse specimens. Double-melted pressure tubes showed relatively higher strength and lower elongation and larger standard deviation compared to the quadruple melted pressure tubes. Mean values of tensile properties showed that back-end off-cuts were relatively stronger and less ductile compared to the front-end off-cuts.

  16. Characterization of the ETEL D784UKFLB 11 in. photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Barros, N.; Kaptanoglu, T. [University of Pennsylvania, Philadelphia, PA 19104 (United States); Kimelman, B. [Muhlenberg College, Allentown, PA 18104 (United States); Klein, J.R. [University of Pennsylvania, Philadelphia, PA 19104 (United States); Moore, E.; Nguyen, J. [University of California, Davis, Davis, CA 95616 (United States); Stavreva, K. [University of Pennsylvania, Philadelphia, PA 19104 (United States); Svoboda, R., E-mail: rsvoboda@physics.ucdavis.edu [University of California, Davis, Davis, CA 95616 (United States)

    2017-04-21

    Water Cherenkov and scintillator detectors are a critical tool for neutrino physics. Their large size, low threshold, and low operational cost make them excellent detectors for long baseline neutrino oscillations, proton decay, supernova and solar neutrinos, double beta decay, and ultra-high energy astrophysical neutrinos. Proposals for a new generation of large detectors rely on the availability of large format, fast, cost-effective photomultiplier tubes. The Electron Tubes Enterprises, Ltd (ETEL) D784KFLB 11 in. Photomultiplier Tube has been developed for large neutrino detectors. We have measured the timing characteristics, relative efficiency, and magnetic field sensitivity of the first fifteen prototypes.

  17. Track chambers based on precision drift tubes housed inside 30 mm mylar pipe

    International Nuclear Information System (INIS)

    Borisov, A; Bozhko, N; Fakhrutdinov, R; Kozhin, A; Leontiev, B; Levin, A

    2014-01-01

    We describe drift chambers consisting of 3 layers of 30 mm (OD) drift tubes made of double sided aluminized mylar film with thickness 0.125 mm. A single drift tube is self-supported structure withstanding 350 g tension of 50 microns sense wire located in the tube center with 10 microns precision with respect to end-plug outer surface. Such tubes allow to create drift chambers with small amount of material, construction of such chambers doesn't require hard frames. Twenty six chambers with working area from 0.8 × 1.0 to 2.5 × 2.0 m 2 including 4440 tubes have been manufactured for experiments at 70-GeV proton accelerator at IHEP(Protvino)

  18. Track chambers based on precision drift tubes housed inside 30 mm mylar pipe

    Science.gov (United States)

    Borisov, A.; Bozhko, N.; Fakhrutdinov, R.; Kozhin, A.; Leontiev, B.; Levin, A.

    2014-06-01

    We describe drift chambers consisting of 3 layers of 30 mm (OD) drift tubes made of double sided aluminized mylar film with thickness 0.125 mm. A single drift tube is self-supported structure withstanding 350 g tension of 50 microns sense wire located in the tube center with 10 microns precision with respect to end-plug outer surface. Such tubes allow to create drift chambers with small amount of material, construction of such chambers doesn't require hard frames. Twenty six chambers with working area from 0.8 × 1.0 to 2.5 × 2.0 m2 including 4440 tubes have been manufactured for experiments at 70-GeV proton accelerator at IHEP(Protvino).

  19. Neonatal enteral feeding tubes as loci for colonisation by members of the Enterobacteriaceae

    Directory of Open Access Journals (Sweden)

    Smith Craig

    2009-09-01

    Full Text Available Abstract Background The objective of this study was to determine whether neonatal nasogastric enteral feeding tubes are colonised by the opportunistic pathogen Cronobacter spp. (Enterobacter sakazakii and other Enterobacteriaceae, and whether their presence was influenced by the feeding regime. Methods One hundred and twenty-nine tubes were collected from two neonatal intensive care units (NICU. A questionnaire on feeding regime was completed with each sample. Enterobacteriaceae present in the tubes were identified using conventional and molecular methods, and their antibiograms determined. Results The neonates were fed breast milk (16%, fortified breast milk (28%, ready to feed formula (20%, reconstituted powdered infant formula (PIF, 6%, or a mixture of these (21%. Eight percent of tubes were received from neonates who were 'nil by mouth'. Organisms were isolated from 76% of enteral feeding tubes as a biofilm (up to 107 cfu/tube from neonates fed fortified breast milk and reconstituted PIF and in the residual lumen liquid (up to 107 Enterobacteriaceae cfu/ml, average volume 250 μl. The most common isolates were Enterobacter cancerogenus (41%, Serratia marcescens (36%, E. hormaechei (33%, Escherichia coli (29%, Klebsiella pneumoniae (25%, Raoultella terrigena (10%, and S. liquefaciens (12%. Other organisms isolated included C. sakazakii (2%,Yersinia enterocolitica (1%,Citrobacter freundii (1%, E. vulneris (1%, Pseudomonas fluorescens (1%, and P. luteola (1%. The enteral feeding tubes were in place between 48 h (13%. All the S. marcescens isolates from the enteral feeding tubes were resistant to amoxicillin and co-amoxiclav. Of additional importance was that a quarter of E. hormaechei isolates were resistant to the 3rd generation cephalosporins ceftazidime and cefotaxime. During the period of the study, K. pneumoniae and S. marcescens caused infections in the two NICUs. Conclusion This study shows that neonatal enteral feeding tubes

  20. Flux tubes at finite temperature

    Energy Technology Data Exchange (ETDEWEB)

    Cea, Paolo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Dipartimento di Fisica dell’Università di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cosmai, Leonardo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cuteri, Francesca; Papa, Alessandro [Dipartimento di Fisica, Università della Calabria & INFN-Cosenza,Ponte Bucci, cubo 31C, I-87036 Rende (Cosenza) (Italy)

    2016-06-07

    The chromoelectric field generated by a static quark-antiquark pair, with its peculiar tube-like shape, can be nicely described, at zero temperature, within the dual superconductor scenario for the QCD confining vacuum. In this work we investigate, by lattice Monte Carlo simulations of the SU(3) pure gauge theory, the fate of chromoelectric flux tubes across the deconfinement transition. We find that, if the distance between the static sources is kept fixed at about 0.76 fm ≃1.6/√σ and the temperature is increased towards and above the deconfinement temperature T{sub c}, the amplitude of the field inside the flux tube gets smaller, while the shape of the flux tube does not vary appreciably across deconfinement. This scenario with flux-tube “evaporation” above T{sub c} has no correspondence in ordinary (type-II) superconductivity, where instead the transition to the phase with normal conductivity is characterized by a divergent fattening of flux tubes as the transition temperature is approached from below. We present also some evidence about the existence of flux-tube structures in the magnetic sector of the theory in the deconfined phase.

  1. Pressure tube reactor

    International Nuclear Information System (INIS)

    Kanazawa, Nobuhiro; Kaneto, Kunikazu.

    1979-01-01

    Purpose: To attain uniform fluid poison distribution in a calandria tank by downwardly projecting, at an equal distance to the reactor core, a spacer wall from the periphery of an anti-vibration plate in the vicinity of a heavy water flow passage in the periphery of the anti-vibration plate, thereby decrease the amount of heavy water flowing into the heavy water flow passage. Constitution: A projecting wall concentrical with a calandria tank is suspended vertically from the boundary side at the peripheral portion of an anti-vibration plate to a water heavy flow passage in the periphery of the anti-vibration plate. The projecting wall has such a vertical length as about equal to the width of the heavy water flow passage, prevents heavy water flowing through apertures of a control rod guide tube from entering into the heavy water passage and increases the ratio of heavy water that flows through the heavy water flow passage in the anti-vibration plate. Consequently, if the liquid poison density in heavy water is varied, the ununiform poison density in the calandria tank can be prevented. (Seki, T.)

  2. A chloroplast thylakoid lumen protein is required for proper photosynthetic acclimation of plants under fluctuating light environments.

    Science.gov (United States)

    Liu, Jun; Last, Robert L

    2017-09-19

    Despite our increasingly sophisticated understanding of mechanisms ensuring efficient photosynthesis under laboratory-controlled light conditions, less is known about the regulation of photosynthesis under fluctuating light. This is important because-in nature-photosynthetic organisms experience rapid and extreme changes in sunlight, potentially causing deleterious effects on photosynthetic efficiency and productivity. Here we report that the chloroplast thylakoid lumenal protein MAINTENANCE OF PHOTOSYSTEM II UNDER HIGH LIGHT 2 (MPH2; encoded by At4g02530 ) is required for growth acclimation of Arabidopsis thaliana plants under controlled photoinhibitory light and fluctuating light environments. Evidence is presented that mph2 mutant light stress susceptibility results from a defect in photosystem II (PSII) repair, and our results are consistent with the hypothesis that MPH2 is involved in disassembling monomeric complexes during regeneration of dimeric functional PSII supercomplexes. Moreover, mph2 -and previously characterized PSII repair-defective mutants-exhibited reduced growth under fluctuating light conditions, while PSII photoprotection-impaired mutants did not. These findings suggest that repair is not only required for PSII maintenance under static high-irradiance light conditions but is also a regulatory mechanism facilitating photosynthetic adaptation under fluctuating light environments. This work has implications for improvement of agricultural plant productivity through engineering PSII repair.

  3. Delivery of Mesenchymal Stem Cells from Gelatin–Alginate Hydrogels to Stomach Lumen for Treatment of Gastroparesis

    Directory of Open Access Journals (Sweden)

    Binata Joddar

    2018-02-01

    Full Text Available Gastroparesis (GP is associated with depletion of interstitial cells of Cajal (ICCs and enteric neurons, which leads to pyloric dysfunction followed by severe nausea, vomiting and delayed gastric emptying. Regenerating these fundamental structures with mesenchymal stem cell (MSC therapy would be helpful to restore gastric function in GP. MSCs have been successfully used in animal models of other gastrointestinal (GI diseases, including colitis. However, no study has been performed with these cells on GP animals. In this study, we explored whether mouse MSCs can be delivered from a hydrogel scaffold to the luminal surfaces of mice stomach explants. Mouse MSCs were seeded atop alginate–gelatin, coated with poly-l-lysine. These cell–gel constructs were placed atop stomach explants facing the luminal side. MSCs grew uniformly all across the gel surface within 48 h. When placed atop the lumen of the stomach, MSCs migrated from the gels to the tissues, as confirmed by positive staining with vimentin and N-cadherin. Thus, the feasibility of transplanting a cell–gel construct to deliver stem cells in the stomach wall was successfully shown in a mice stomach explant model, thereby making a significant advance towards envisioning the transplantation of an entire tissue-engineered ‘gastric patch’ or ‘microgels’ with cells and growth factors.

  4. Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis

    International Nuclear Information System (INIS)

    Spuentrup, Elmar; Botnar, Rene M.

    2006-01-01

    Coronary magnetic resonance (MR) imaging has dramatically emerged over the last decade. Technical improvements have enabled reliable visualization of the proximal and midportion of the coronary artery tree for exclusion of significant coronary artery disease. However, current technical developments focus also on direct visualization of the diseased coronary vessel wall and imaging of coronary plaque because plaques without stenoses are typically more vulnerable with higher risk of plaque rupture. Plaque rupture with subsequent thrombosis and vessel occlusion is the main cause of myocardial infarction. Very recently, the first success of molecular imaging in the coronary arteries has been demonstrated using a fibrin-specific contrast agent for selective visualization of coronary thrombosis. This demonstrates in general the high potential of molecular MR imaging in the field of coronary artery disease. In this review, we will address recent technical advances in coronary MR imaging, including visualization of the lumen and the vessel wall and molecular imaging of coronary arteriothrombosis. First results of these new approaches will be discussed. (orig.)

  5. Internal heat exchange tubes for industrial furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, M.; Lingle, T.M.

    1992-05-26

    This patent describes a method for cooling the work within an industrial furnace. It comprises providing a longitudinally extending outer tube which extends into the furnace having a closed axial end and an open axial end; providing a preformed inner tube open at both ends within the outer tube; injecting a coolant into the inner tube so that the coolant flows from one axial end of the tube out the opposite end adjacent the closed end of the outer tube, and from the closed end of the outer tube to the open end thereof; circulating a gas within the furnace against the outer tube to effect heat transfer therewith.

  6. Patient identification and tube labelling

    DEFF Research Database (Denmark)

    van Dongen-Lases, Edmée C; Cornes, Michael P; Grankvist, Kjell

    2016-01-01

    of phlebotomy procedures with the CLSI H3-A6 guideline was unacceptably low, and that patient identification and tube labelling are amongst the most critical steps in need of immediate attention and improvement. The process of patient identification and tube labelling is an essential safety barrier to prevent...... patient identity mix-up. Therefore, the EFLM Working Group aims to encourage and support worldwide harmonisation of patient identification and tube labelling procedures in order to reduce the risk of preanalytical errors and improve patient safety. With this Position paper we wish to raise awareness...... and provide recommendations for proper patient and sample identification procedures....

  7. PEG tubes: dealing with complications.

    Science.gov (United States)

    Malhi, Hardip; Thompson, Rosie

    A percutaneous endoscopic gastronomy tube can be used to deliver nutrition, hydration and medicines directly into the patient's stomach. Patients will require a tube if they are unable to swallow safely, putting them at risk of aspiration of food, drink and medicines into their lungs. It is vital that nurses are aware of the complications that may arise when caring for a patient with a PEG tube. It is equally important that nurses know how to deal with these complications or from where tc seek advice. This article provides a quick troubleshooting guide to help nurses deal with complications that can arise with PEG feeding.

  8. Applications of liquid scintillation tubes

    International Nuclear Information System (INIS)

    Broga, D.W.

    1977-01-01

    A new cocktail containing device for liquid scintillation counting, the scintillation tube, consists of a two-layered plastic bag which is heatsealed after the cocktail and sample have been placed in it. It is then placed in a carrying vial and counted in a conventional liquid scintillation counter. These tubes have proved to be a practical and economical alternative to vials. Some of their advantages are elimination of absorption problems, transparency, lower background and higher counting efficiency, low breakage danger and savings in waste disposal costs. Two applications for which the tubes are particularly suitable are the counting of laboratory swipes and urine analysis. (author)

  9. Condenser tube buckling within tube-tubesheet joints

    International Nuclear Information System (INIS)

    Willertz, L.E.; Kalnins, A.; Updike, D.P.

    1991-01-01

    The problem of the appearance of protrusions, or bumps, in the interior of roller-expanded tubes within a tubesheet is addressed. Such bumps have been observed in condensers of power plants. A brief history of the reported occurrences of the bumps is given. The hypothesis is advanced that the mechanics of the formation of the bumps is similar to a buckling problem that has 'bifurcation at infinity'. Following this hypothesis, a two-dimensional physical model is developed, and the application of this model to study a three-dimensional bump is proposed. It is proposed in this paper that an initial deviation from the circular shape of the tube required to produce a bump. It is shown that without such a deviation the tubes cannot buckle. An experiment with short tube segments has been performed that verifies some of the features of the observed condenser tube bumps. Exactly what force produced the initial deviation for the observed bumps is still unknown. Available evidence implicates the hydro-laser jet that is used in the cleaning of tubes and tubesheets. A scenario of how a bump could have been produced by the hydro-laser jet is proposed. (author)

  10. Vertical steam generator with slab-type tube-plate with even tube bundle washing

    International Nuclear Information System (INIS)

    Manek, O.; Masek, V.; Motejl, V.; Quitta, R.

    1980-01-01

    A shielding plate supporting the tubes attached to the tube plate of a vertical steam generator is mounted above the tube plate. Tube sleeves are designed with a dimensional tolerance relative to the heat transfer tubes and the sleeve end and the tube plate end. A separate space is thus formed above the tube plate in which circulation or feed water is introduced to flow between the branch and the heat transfer tube. This provides intensive washing of heat transfer tubes at a critical point and prevents deposit formation, thus excluding heat transfer tube failures. (J.B.)

  11. International double taxation

    OpenAIRE

    Körbl, Hugo

    2012-01-01

    1 Summary This thesis deals with the issue of international double taxation of income and capital and methods for its solution. International double taxation is an issue which states began to deal with in the late 19th century. This interest intensified after the First World War when also the League of Nations (predecessor of the United Nations) began to deal with international double taxation. Most attention the phenomenon of double taxation of income and capital with an international elemen...

  12. Thermal effect on transverse vibrations of double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Zhang, Y Q; Liu, X; Liu, G R

    2007-01-01

    Based on the theory of thermal elasticity mechanics, a double-elastic beam model is developed for transverse vibrations of double-walled carbon nanotubes with large aspect ratios. The thermal effect is incorporated in the formulation. With this double-elastic beam model, explicit expressions are derived for natural frequencies and associated amplitude ratios of the inner to the outer tubes for the case of simply supported double-walled carbon nanotubes. The influence of temperature change on the properties of transverse vibrations is discussed. It is demonstrated that some properties of transverse vibrations of double-walled carbon nanotubes are dependent on the change of temperature

  13. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded ...

  14. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  15. Technique for joining metal tubing

    Science.gov (United States)

    Wright, H. W.

    1976-01-01

    Uniform wall thickness and uninterrupted heat transfer is achieved by using shaped metal insert as wall material for joint. Insert acts as support during brazing, after which excess material is ground away to bring joint to original tubing size.

  16. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division ... Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video ...

  17. Cuffed endotracheal tubes in paediatrics

    African Journals Online (AJOL)

    cuffed endotracheal tubes (CETTs) in children who are younger than eight years old. Most paediatric ... the smallest functional part of the infant airway, because the ... During the 2003 severe acute respiratory syndrome (SARS) outbreak in ...

  18. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino ... To search for current job openings visit HHS USAJobs Home » NEI YouTube ...

  19. Eddy current tube testing unit

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Duret, G.

    1975-01-01

    The unit described can check a wide variety of tubes in quick succession and its modular design gives it a high degree of versability. Suitably defined working conditions and specific fittings enable most of the faults encountered in the manufacture of a tube to be detected. By appropriate means of selection based on signal amplitude, phase and frequency analyses it is possible to adapt selection criteria to the seriousness of the different categories of defect [fr

  20. The YouTube reader

    OpenAIRE

    2009-01-01

    YouTube has come to epitomize the possibilities of digital culture. With more than seventy million unique users a month and approximately eighty million videos online, this brand-name video distribution platform holds the richest repository of popular culture on the Internet. As the fastest growing site in the history of the Web, YouTube promises endless new opportunities for amateur video, political campaigning, entertainment formats, and viral marketing—a clip culture that has seemed to out...

  1. Gasification in a revolving tube

    International Nuclear Information System (INIS)

    Speicher, R.F.

    1981-01-01

    The concept of a method for allothermal coal gasification is to refine raw lignite from the Rhine area to high-quality synthesis gas or reduction gas without extracting the water utilizing nuclear process heat in a heated revolving bundle of tubes. Computational models are described for the macroscopic course of events in parallel flow gasification. In the design of the test plant, the principle of drag-in and transport of the tube drier was applied. (DG) [de

  2. Electronics for proportional drift tubes

    International Nuclear Information System (INIS)

    Fremont, G.; Friend, B.; Mess, K.H.; Schmidt-Parzefall, W.; Tarle, J.C.; Verweij, H.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Geske, K.; Riege, H.; Schuett, J.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Semenov, Y.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration)

    1980-01-01

    An electronic system for the read-out of a large number of proportional drift tubes (16,000) has been designed. This system measures deposited charge and drift-time of the charge of a particle traversing a proportional drift tube. A second event can be accepted during the read-out of the system. Up to 40 typical events can be collected and buffered before a data transfer to a computer is necessary. (orig.)

  3. Tube-in-shell heat exchangers

    International Nuclear Information System (INIS)

    Richardson, J.

    1976-01-01

    Tube-in-shell heat exchangers normally comprise a bundle of parallel tubes within a shell container, with a fluid arranged to flow through the tubes in heat exchange with a second fluid flowing through the shell. The tubes are usually end supported by the tube plates that separate the two fluids, and in use the tube attachments to the tube plates and the tube plates can be subject to severe stress by thermal shock and frequent inspection and servicing are required. Where the heat exchangers are immersed in a coolant such as liquid Na such inspection is difficult. In the arrangement described a longitudinally extending central tube is provided incorporating axially spaced cylindrical tube plates to which the opposite ends of the tubes are attached. Within this tube there is a tubular baffle that slidably seals against the wall of the tube between the cylindrical tube plates to define two co-axial flow ducts. These ducts are interconnected at the closed end of the tube by the heat exchange tubes and the baffle comprises inner and outer spaced walls with the interspace containing Ar. The baffle is easily removable and can be withdrawn to enable insertion of equipment for inspecting the wall of the tube and tube attachments and to facilitate plugging of defective tubes. Cylindrical tube plates are believed to be superior for carrying pressure loads and resisting the effects of thermal shock. Some protection against thermal shock can be effected by arranging that the secondary heat exchange fluid is on the tube side, and by providing a thermal baffle to prevent direct impingement of hot primary fluid on to the cylindrical tube plates. The inner wall of the tubular baffle may have flexible expansible region. Some nuclear reactor constructions incorporating such an arrangement are described, including liquid metal reactors. (U.K.)

  4. Dermatology on YouTube.

    Science.gov (United States)

    Boyers, Lindsay N; Quest, Tyler; Karimkhani, Chante; Connett, Jessica; Dellavalle, Robert P

    2014-06-15

    YouTube, reaches upwards of six billion users on a monthly basis and is a unique source of information distribution and communication. Although the influence of YouTube on personal health decision-making is well established, this study assessed the type of content and viewership on a broad scope of dermatology related content on YouTube. Select terms (i.e. dermatology, sun protection, skin cancer, skin cancer awareness, and skin conditions) were searched on YouTube. Overall, the results included 100 videos with over 47 million viewers. Advocacy was the most prevalent content type at 24% of the total search results. These 100 videos were "shared" a total of 101,173 times and have driven 6,325 subscriptions to distinct YouTube user pages. Of the total videos, 35% were uploaded by or featured an MD/DO/PhD in dermatology or other specialty/field, 2% FNP/PA, 1% RN, and 62% other. As one of the most trafficked global sites on the Internet, YouTube is a valuable resource for dermatologists, physicians in other specialties, and the general public to share their dermatology-related content and gain subscribers. However, challenges of accessing and determining evidence-based data remain an issue.

  5. Double layers in space

    International Nuclear Information System (INIS)

    Carlqvist, P.

    1982-07-01

    For more than a decade it has been realised that electrostatic double layers are likely to occur in space. We briefly discuss the theoretical background of such double layers. Most of the paper is devoted to an account of the observational evidence for double layers in the ionosphere and magnetosphere of the Earth. Several different experiments are reviewed including rocket and satellite measurements and ground based observations. It is concluded that the observational evidence for double layers in space is very strong. The experimental results indicate that double layers with widely different properties may exist in space. (Author)

  6. Double layers in space

    International Nuclear Information System (INIS)

    Carlqvist, P.

    1982-01-01

    For more than a decade it has been realised that electrostatic double layers are likely to occur in space. The author briefly discusses the theoretical background of such double layers. Most of the paper is devoted to an account of the observational evidence for double layers in the ionosphere and magnetosphere of the Earth. Several different experiments are reviewed including rocket and satellite measurements and ground based observations. It is concluded that the observational evidence for double layers in space is very strong. The experimental results indicate that double layers with widely different properties may exist in space. (Auth.)

  7. Double-double effect and coordination number

    International Nuclear Information System (INIS)

    Mioduski, T.

    1992-01-01

    The original method of interpretation together with its theoretical foundations is developed, making it possible to use location and direction of the double-double (tetrad) effect within the Ln and An series to determine the coordination number (CN) complexes of the f-block elements. The method is applied for potentiometric and radiometric equilibrium studies. It has been pointed and that the decisive factor for the direction of the double-double effect in the case of the Gibbs energy variations is a difference in the CN of the f-element ion between the reaction product complex and that for the reaction substrate the ''regular'' effect for a given tetrad is accompanied by decrease in the CN while the ''reverse'' effect by increase in the CN. (author). 122 refs, 5 tabs, 8 figs

  8. Plastic Response of Tracheids in Pinus pinaster in a Water-Limited Environment: Adjusting Lumen Size instead of Wall Thickness.

    Directory of Open Access Journals (Sweden)

    Ana Carvalho

    Full Text Available The formation of wood results from cambial activity and its anatomical properties reflect the variability of environmental conditions during the growing season. Recently, it was found that wood density variations in conifers growing under cold-limited environment result from the adjustment of cell wall thickness (CWT to temperature. Additionally, it is known that intra-annual density fluctuations (IADFs are formed in response to precipitation after the summer drought. Although IADFs are frequent in Mediterranean conifers no study has yet been conducted to determine if these structures result from the adjustment of lumen diameter (LD or CWT to soil water availability. Our main objective is to investigate the intra-ring variation of wood anatomical features (LD and CWT in Pinus pinaster Ait. growing under a water-limited environment. We compared the tracheidograms of LD and CWT for the years 2010-2013 in P. pinaster growing in the west coast of Portugal. Our results suggest a close association between LD and soil moisture content along the growing season, reinforcing the role of water availability in determining tracheid size. Compared with CWT, LD showed a higher intra- and inter-annual variability suggesting its strong adjustment value to variations in water availability. The formation of a latewood IADF appears to be predisposed by higher rates of cell production in spring and triggered by early autumn precipitation. Our findings reinforce the crucial role of water availability on cambial activity and wood formation in Mediterranean conifers, and emphasize the high plasticity of wood anatomical features under Mediterranean climate.

  9. The Functional Lumen Imaging Probe Detects Esophageal Contractility Not Observed With Manometry in Patients With Achalasia.

    Science.gov (United States)

    Carlson, Dustin A; Lin, Zhiyue; Kahrilas, Peter J; Sternbach, Joel; Donnan, Erica N; Friesen, Laurel; Listernick, Zoe; Mogni, Benjamin; Pandolfino, John E

    2015-12-01

    The functional lumen imaging probe (FLIP) could improve the characterization of achalasia subtypes by detecting nonocclusive esophageal contractions not observed with standard manometry. We aimed to evaluate esophageal contractions during volumetric distention in patients with achalasia using FLIP topography. Fifty-one treatment-naive patients with achalasia, defined and subclassified by high-resolution esophageal pressure topography, and 10 asymptomatic individuals (controls) were evaluated with the FLIP during endoscopy. During stepwise distension, simultaneous intrabag pressures and 16 channels of cross-sectional areas were measured; data were exported to software that generated FLIP topography plots. Esophageal contractility was identified by noting periods of reduced luminal diameter. Esophageal contractions were characterized further by propagation direction, repetitiveness, and based on whether they were occluding or nonoccluding. Esophageal contractility was detected in all 10 controls: 8 of 10 had repetitive antegrade contractions and 9 of 10 had occluding contractions. Contractility was detected in 27% (4 of 15) of patients with type I achalasia and in 65% (18 of 26, including 9 with occluding contractions) of patients with type II achalasia. Contractility was detected in all 10 patients with type III achalasia; 8 of these patients had a pattern of contractility that was not observed in controls (repetitive retrograde contractions). Esophageal contractility not observed with manometry can be detected in patients with achalasia using FLIP topography. The presence and patterns of contractility detected with FLIP topography may represent variations in pathophysiology, such as mechanisms of panesophageal pressurization in patients with type II achalasia. These findings could have implications for additional subclassification to supplement prediction of the achalasia disease course. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights

  10. Verso una filosofia della luce e dell’ascolto? Il secondo capitolo dell’enciclica sul Lumen fidei

    Directory of Open Access Journals (Sweden)

    Pasquale Giustiniani

    2014-03-01

    Full Text Available Normal 0 14 false false false MicrosoftInternetExplorer4 Science without religion is lame, religion without science is blind. This phrase, attributed to Albert Einstein, with the implicit metaphor of light, through blindness, would have wanted to emphasize that faith and science are not irreconcilables. This paper means, at the urging of Pope Francis (but also of Pope Benedict XVI, as we shall see, that is possible to reflect on the relationships between religion and science, faith and reason, theology and philosophy, ethics, religion and art, Hellenism and Christianity, biblical message and achievements of the recent reason… in the light of the second chapter of the encyclical Lumen fidei. In this chapter, summarizing some aspects of the life of St. Augustine, the encyclical speaks of the decisive moment in his journey of faith, identifying listening to the voice of God (philosophy of listening  but never he refuse the light and vision (philosophy of light. From this result, can be proposed again a reflection in predominantly philosophical and religious perspective, with much attention to acoustic and visual perception of the divine, by which the ancient pairs of terms between faith and reason, theology - philosophy, faith - science ... /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabella normale"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}

  11. Plastic Response of Tracheids in Pinus pinaster in a Water-Limited Environment: Adjusting Lumen Size instead of Wall Thickness.

    Science.gov (United States)

    Carvalho, Ana; Nabais, Cristina; Vieira, Joana; Rossi, Sergio; Campelo, Filipe

    2015-01-01

    The formation of wood results from cambial activity and its anatomical properties reflect the variability of environmental conditions during the growing season. Recently, it was found that wood density variations in conifers growing under cold-limited environment result from the adjustment of cell wall thickness (CWT) to temperature. Additionally, it is known that intra-annual density fluctuations (IADFs) are formed in response to precipitation after the summer drought. Although IADFs are frequent in Mediterranean conifers no study has yet been conducted to determine if these structures result from the adjustment of lumen diameter (LD) or CWT to soil water availability. Our main objective is to investigate the intra-ring variation of wood anatomical features (LD and CWT) in Pinus pinaster Ait. growing under a water-limited environment. We compared the tracheidograms of LD and CWT for the years 2010-2013 in P. pinaster growing in the west coast of Portugal. Our results suggest a close association between LD and soil moisture content along the growing season, reinforcing the role of water availability in determining tracheid size. Compared with CWT, LD showed a higher intra- and inter-annual variability suggesting its strong adjustment value to variations in water availability. The formation of a latewood IADF appears to be predisposed by higher rates of cell production in spring and triggered by early autumn precipitation. Our findings reinforce the crucial role of water availability on cambial activity and wood formation in Mediterranean conifers, and emphasize the high plasticity of wood anatomical features under Mediterranean climate.

  12. Perioperative echocardiography for invasive thymoma with ...

    African Journals Online (AJOL)

    ... of the mass and haemodynamic changes secondary to compression.3,4 Previous literature has ... The right middle lobe; medial and lateral segmental bronchi; right ... size 35 Fr left double lumen endotracheal tube was sited. Maintenance of ...

  13. Tubing vs. buckets: a cost comparison

    Science.gov (United States)

    Neil K. Huyler

    1975-01-01

    Equipment investment for tubing-vacuum systems was significantly less than that for bucket systems. Tubing-vacuum systems required about 22 percent less labor input, the major labor input being completed before sap-flow periods. Annual cost of operation was less for tubing-vacuum than the bucket system. Small tubing-vacuum operations showed more profit potential than...

  14. Expander for Thin-Wall Tubing

    Science.gov (United States)

    Pessin, R.

    1983-01-01

    Tool locally expands small-diameter tubes. Tube expander locally expands and deforms tube: Compressive lateral stress induced in elastomeric sleeve by squeezing axially between two metal tool parts. Adaptable to situations in which tube must have small bulge for mechanical support or flow control.

  15. Cross-talk in straw tube chambers

    Energy Technology Data Exchange (ETDEWEB)

    Marzec, J. E-mail: janusz.marzec@ire.pw.edu.pl

    2003-05-11

    An analytical model of the signal transmission between neighboring straw tubes with resistive cathodes (cross-talk) is presented. The dependence of the cross-talk level on the cathode resistance, tube length, particle detection point, the distance of the tube from the shielding planes, and termination of the tube ends is analyzed.

  16. Cross-talk in straw tube chambers

    International Nuclear Information System (INIS)

    Marzec, J.

    2003-01-01

    An analytical model of the signal transmission between neighboring straw tubes with resistive cathodes (cross-talk) is presented. The dependence of the cross-talk level on the cathode resistance, tube length, particle detection point, the distance of the tube from the shielding planes, and termination of the tube ends is analyzed

  17. X-ray topography with scintillators coupled to image intensifiers or camera tubes

    International Nuclear Information System (INIS)

    Beauvais, Yves; Mathiot, Alain.

    1978-01-01

    The possibility of imaging topographic figures in real time by using a thin scintillator coupled to either a high-gain image intensifier or a camera tube is investigated. The camera tube must have a high gain because of the low photon fluxes that are encountered in practice, and because of the relatively low quantum yield of thin phosphors. With conventional X-ray generators, the resolution is photon-noise limited. With more powerful generators like synchrotrons, real-time imaging appears possible, and the resolution is limited by the modulation transfer function of the image tube. Higher resolution can be reached by increasing the magnification between the screen and the image tube. When doing so, the input field is reduced and thinner phosphor screens must be used, resulting in a lower yield. Each time the magnification is doubled, the minimum required photon flux is multiplier by about 8, so that the advantages of increasing the magnification are rapidly limited, so far as real-time imaging is concerned. Because image tube resolution is mainly limited by the modulation transfer function of the phosphor for image intensifiers, and by that of the target for camera tubes, improvement of photocathode resolution can be obtained by magnifying electron optics. A zooming electron optic would permit the field and the resolution of the tube to be adapted to the observed subject. Unfortunately such tubes do not exist at present for this type of application, and in the required size

  18. Analysis of temperature and stress distribution of superheater tubes after attemperation or sootblower activation

    International Nuclear Information System (INIS)

    Madejski, Paweł; Taler, Dawid

    2013-01-01

    Highlights: • The CFD simulation was used to calculate 3D steam and tube wall temperature distributions in the platen superheater. • The CFD results can be used in design of superheaters made of tubes with complex cross-section. • The CFD analysis enables the proper selection of the steel grade. • The transient temperature and stress distributions were calculated using Finite Volume Method. • The detailed analysis prevents superheater tubes from excessive stresses during sootblower or attemperator activation. - Abstract: Superheaters are characterized by high metal temperatures due to higher steam temperature and low heat transfer coefficients on the tube inner surfaces. Superheaters have especially difficult operating conditions, particularly during attemperator and sootblower activations, when temperature and steam flow rate as well as tube wall temperature change with time. A detailed thermo-mechanical analysis of the superheater tubes makes it possible to identify the cause of premature high-temperature failures and aids greatly in the changes in tubing arrangement and improving start-up technology. This paper presents a thermal and strength analysis of a tubedouble omega”, used in the steam superheaters in CFB boilers

  19. A Study on the Development of Nonglass Solar Vacuum Tube Collector

    International Nuclear Information System (INIS)

    Oh, Seung Jin

    2008-02-01

    Nature has been providing us energy from the beginning of the world. However human has hardly used it wisely. Solar energy is a kind of renewable energy from the nature. This study has been carried out to study the use of solar energy as it is harnessed in the form of thermal energy. Solar energy is one of the most promising energy resources such as hydrogen, biomass, wind and geothermal energy, because it is clean and inexhaustible. Space heating in buildings can be provided from solar energy by systems that are similar in many respects to water heater systems. By tapping into solar energy, we can not only solve the problem of energy shortage, but also can protect the environment and benefit the human beings. There are currently two types of evacuated tube; a single glass tube and a double glass tube. The former consists of a single glass tube which contains a flat or curved aluminium plate attached to a copper heat pipe or water flow pipe. The latter consists of rows of parallel transparent glass tubes, each of which contains an absorber tube. Evacuated tube collectors introduced above, however, pose some problems as they break rather easily under mechanical stresses. This paper introduces some preliminary results in design and fabrication of a non-glass solar vacuum tube collector in which the thermosyphon(heat pipe)made of copper is used as a heat transfer device. A series of tests have been performed to assess the ability of a non-glass solar vacuum tube collector. The series of experiments are as follows: 1)Vacuum level inside a vacuum tube. 2)Effects of the air remaining inside a vacuum tube on the temperature on the absorber plate. 3)Comparison of a non-glass vacuum solar collector with a single glass evacuated tube(SEIDO 5). Different vacuum levels inside non-glass vacuum tubes were applied to check any leakage or unexpected physical or chemical developments with time. The vacuum level changed from 10 -2 torr to 5torr in 5 days due to air infiltration from

  20. PWR steam generator tubing sample library

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    In order to compile the tubing sample library, two approaches were employed: (a) tubing sample replication by either chemical or mechanical means, based on field tube data and metallography reports for tubes already destructively examined; and (b) acquisition of field tubes removed from operating or retired steam generators. In addition, a unique mercury modeling concept is in use to guide the selection of replica samples. A compendium was compiled that summarizes field observations and morphologies of steam generator tube degradation types based on available NDE, destructive examinations, and field reports. This compendium was used in selecting candidate degradation types that were manufactured for inclusion in the tube library

  1. CALiPER Retail Lamps Study RRL3.2 Lumen and Chromaticity Maintenance of LED A lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McCullough, Jeffrey J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Joseph C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The lumen depreciation and color shift of 17 different A lamps (15 LED, 1 CFL, 1 halogen) was monitored in the automated long-term test apparatus (ALTA) for more than 7,500 hours. Ten samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at an ambient temperature of 45°C (-1°C). Importantly, the steady-state test conditions were not optimized for inducing catastrophic failure for any of the lamp technologies—to which thermal cycling is a strong contributor— and are not typical of normal use patterns—which usually include off periods where the lamp cools down. Further, the test conditions differ from those used in standardized long-term test methods (i.e., IES LM-80, IES LM-84), so the results should not be directly compared. On the other hand, the test conditions are similar to those used by ENERGY STAR (when elevated temperature testing is called for). Likewise, the conditions and assumptions used by manufacturers to generated lifetime claims may vary; the CALiPER long-term data is informative, but cannot necessarily be used to discredit manufacturer claims. The test method used for this investigation should be interpreted as one more focused on the long-term effects of elevated temperature operation, at an ambient temperature that is not uncommon in luminaires. On average, the lumen maintenance of the LED lamps monitored in the ALTA was better than benchmark lamps, but there was considerable variation from lamp model to lamp model. While three lamp models had average lumen maintenance above 99% at the end of the study period, two products had average lumen maintenance below 65%, constituting a parametric failure. These two products, along with a third, also exhibited substantial color shift, another form of parametric failure. While none of the LED lamps exhibited catastrophic failure—and all of the benchmarks did—the early degradation of performance is concerning, especially with a

  2. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  3. Managing a chest tube and drainage system.

    Science.gov (United States)

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  4. Joint segmentation of lumen and outer wall from femoral artery MR images: Towards 3D imaging measurements of peripheral arterial disease.

    Science.gov (United States)

    Ukwatta, Eranga; Yuan, Jing; Qiu, Wu; Rajchl, Martin; Chiu, Bernard; Fenster, Aaron

    2015-12-01

    Three-dimensional (3D) measurements of peripheral arterial disease (PAD) plaque burden extracted from fast black-blood magnetic resonance (MR) images have shown to be more predictive of clinical outcomes than PAD stenosis measurements. To this end, accurate segmentation of the femoral artery lumen and outer wall is required for generating volumetric measurements of PAD plaque burden. Here, we propose a semi-automated algorithm to jointly segment the femoral artery lumen and outer wall surfaces from 3D black-blood MR images, which are reoriented and reconstructed along the medial axis of the femoral artery to obtain improved spatial coherence between slices of the long, thin femoral artery and to reduce computation time. The developed segmentation algorithm enforces two priors in a global optimization manner: the spatial consistency between the adjacent 2D slices and the anatomical region order between the femoral artery lumen and outer wall surfaces. The formulated combinatorial optimization problem for segmentation is solved globally and exactly by means of convex relaxation using a coupled continuous max-flow (CCMF) model, which is a dual formulation to the convex relaxed optimization problem. In addition, the CCMF model directly derives an efficient duality-based algorithm based on the modern multiplier augmented optimization scheme, which has been implemented on a GPU for fast computation. The computed segmentations from the developed algorithm were compared to manual delineations from experts using 20 black-blood MR images. The developed algorithm yielded both high accuracy (Dice similarity coefficients ≥ 87% for both the lumen and outer wall surfaces) and high reproducibility (intra-class correlation coefficient of 0.95 for generating vessel wall area), while outperforming the state-of-the-art method in terms of computational time by a factor of ≈ 20. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Analysis of forming limit in tube hydroforming

    International Nuclear Information System (INIS)

    Kim, Chan Il; Yang, Seung Hang; Kim, Young Suk

    2013-01-01

    The automotive industry has shown increasing interest in tube hydroforming. Despite many automobile structural parts being produced from cylindrical tubes, failures frequently occur during tube hydroforming under improper forming conditions. These problems include wrinkling, buckling, folding back, and bursting. We perform analytical studies to determine forming limits in tube hydroforming and demonstrate how these forming limits are influenced by the loading path. Theoretical results for the forming limits of wrinkling and bursting are compared with experimental results for an aluminum tube.

  6. Endotracheal tube defects: Hidden causes of airway obstruction

    Directory of Open Access Journals (Sweden)

    Sofi Khalid

    2010-01-01

    Full Text Available Manufacturing defects of endotracheal tube (ETT are still encountered in anesthesia practice. Many such defects go unnoticed during routine inspection prior to their use. Such defects in ETT may lead to partial or complete airway obstruction in an intubated patient. We report a case of partial airway obstruction with a prepacked, single use, uncuffed ETT due to a manufacturing defect in the form of a plastic meniscus at the distal end of the tube. This case report highlights the significance of standard monitoring of ventilation and the role of a vigilant clinician in detecting such defects in avoiding critical events as can arise from the use of such defective ETTs. It also emphasizes the need for double checking ETTs prior to their use.

  7. The beginning of a seed: regulatory mechanisms of double fertilization.

    Science.gov (United States)

    Bleckmann, Andrea; Alter, Svenja; Dresselhaus, Thomas

    2014-01-01

    THE LAUNCH OF SEED DEVELOPMENT IN FLOWERING PLANTS (ANGIOSPERMS) IS INITIATED BY THE PROCESS OF DOUBLE FERTILIZATION: two male gametes (sperm cells) fuse with two female gametes (egg and central cell) to form the precursor cells of the two major seed components, the embryo and endosperm, respectively. The immobile sperm cells are delivered by the pollen tube toward the ovule harboring the female gametophyte by species-specific pollen tube guidance and attraction mechanisms. After pollen tube burst inside the female gametophyte, the two sperm cells fuse with the egg and central cell initiating seed development. The fertilized central cell forms the endosperm while the fertilized egg cell, the zygote, will form the actual embryo and suspensor. The latter structure connects the embryo with the sporophytic maternal tissues of the developing seed. The underlying mechanisms of double fertilization are tightly regulated to ensure delivery of functional sperm cells and the formation of both, a functional zygote and endosperm. In this review we will discuss the current state of knowledge about the processes of directed pollen tube growth and its communication with the synergid cells resulting in pollen tube burst, the interaction of the four gametes leading to cell fusion and finally discuss mechanisms how flowering plants prevent multiple sperm cell entry (polyspermy) to maximize their reproductive success.

  8. Double-sided microtron at Nihon University

    International Nuclear Information System (INIS)

    Tanaka, T.; Hayakawa, K.; Yatoh, H.; Yoshida, K.; Takeda, O.; Sato, K.; Torizuka, Y.

    1990-01-01

    Construction of a 35 MeV cw double-sided microtron (DSM) at Nihon University was started in 1984 and completed in the spring of 1989. This machine was constructed as a proto-type of an 1 GeV cw double sided microtron for a medical pion facility and test accelerator for FEL and other applications. The 4.55 MeV electron beam from 5 MeV injector linac is injected to the DSM. The energy gain is 6 MeV at each turn acceleration. After recirculated 5 times, the electron beam with 34.5 MeV is extracted at the final short straight section. The DAW structure is used for all the accelerating tubes including the injector linac. Total rf power of 200 kW is provided by four 50 kW klystrons of 2450 MHz. (author)

  9. The effect and influence of lumen holmium laser lithotripsy on serum oxidative stress proteins and inflammatory factors of ureteral calculi patients

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2016-09-01

    Full Text Available Objective: To investigate the effect and influence of lumen holmium laser lithotripsy on treating serum oxidative stress proteins and inflammatory factors of patients with ureteral calculi. Methods: A total of 120 cases of patients with ureteral calculi treated in our hospital from May 2010 to Nov 2014 were enrolled in this research for an analysis study. The effect and influence on serum oxidative stress proteins and inflammatory factors of lumen holmium laser lithotripsy on ureteral calculi patients were assayed. Then 120 cases of healthy subjects in our hospital at the same period were taken as control. Results: Among the 120 cases of ureteral calculi patients, 113 cases of patients showed successful operation, with a success rate of 94.2%. The average calculi-discharged time was (28.4 ± 11.2 d and the average operation time was (58.9 ± 10.7 min, while the postoperative hospital stay is (3.8 ± 1.2 d. The results also showed that the levels of NOX1. NOX3, NOX4 and NOX5, and levels of interleukin-2 (IL-2, IL-6, IL-10 and TNF-α of patients with ureteral calculi were significantly higher, compared with the control group, and these parameters were normalized greatly after operation with that the levels of them were significantly different from those before operation. Conclusion: Lumen holmium laser lithotripsy exerts a significant effect on ureteral calculi patients and the oxidative stress parameters and inflammatory factor were normalized greatly.

  10. Analysis of autofrettaged metal tubes

    International Nuclear Information System (INIS)

    Malik, M. Afzaal; Khan, Muddasar; Rashid, Badar; Khushnood, Shahab

    2007-01-01

    Thick-walled cylinders are widely used as compressor cylinders, pump cylinders, high pressure tubing, process reactors and vessels, nuclear reactors, isostatic vessels and gun barrels. In practice, cylinders are generally subjected to sudden and frequently drastic pressure fluctuations, such as the pressure generated in a gun barrel upon the firing of the weapon, pressure reversals in pump cylinders or in process reactors employing high-pressure piping, necessitating enhanced strength of such cylinders. A process for enhancing the strength of thick-walled cylinders has been in service, and is referred to as 'autofrettage'. It extends the service life of the cylinder. The autofrettage is achieved by increasing elastic strength of a cylinder with various methods such as hydraulic pressurization, mechanical swaging, or by utilizing the pressure of a powder gas. This research work deals with the hydraulic and mechanical autofrettage of metal tubes with the objective to attain enhanced strength. Five metal tubes are taken randomly for analysis purpose. The experimental data for five metal tubes is obtained to analyze the behavior of different parameters used during, before, and after autofrettage process. For this research, two-stage autofrettage is taken into consideration. The modeling of the metal tube is carried out in WildFire-ProEngineering, and for analysis purpose, finite element software ANSYS7 and COSMOS are used. The graphical analysis of swage autofrettage is carried out using MATLAB7. The results are validated using available experimental and numerical data. (author)

  11. Physics of magnetic flux tubes

    CERN Document Server

    Ryutova, Margarita

    2015-01-01

    This book is the first account of the physics of magnetic flux tubes from their fundamental properties to collective phenomena in an ensembles of flux tubes. The physics of magnetic flux tubes is absolutely vital for understanding fundamental physical processes in the solar atmosphere shaped and governed by magnetic fields. High-resolution and high cadence observations from recent space and  ground-based instruments taken simultaneously at different heights and temperatures not only show the ubiquity of filamentary structure formation but also allow to study how various events are interconnected by system of magnetic flux tubes. The book covers both theory and observations. Theoretical models presented in analytical and phenomenological forms are tailored for practical applications. These are welded with state-of-the-art observations from early decisive ones to the most recent data that open a new phase-space for exploring the Sun and sun-like stars. Concept of magnetic flux tubes is central to various magn...

  12. Drift tubes of Linac 2

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    With the advent of the 800 MeV PS Booster in 1972, the original injector of the PS, a 50 MeV Alvarez-type proton linac, had reached its limits, in terms of intensity and stability. In 1973 one therefore decided to build a new linac (Linac 2), also with a drift-tube Alvarez structure and an energy of 50 MeV. It had a new Cockcroft-Walton preinjector with 750 keV, instead of the previous one with 500 keV. Linac 2 was put into service in 1980. The old Linac 1 was then used for the study of, and later operation with, various types of ions. This picture shows Linac 2 drift-tubes, suspended on stems coming from the top, in contrast to Linac 1, where the drift-tubes stood on stems coming from the bottom.

  13. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  14. Tubing and cable cutting tool

    Science.gov (United States)

    Mcsmith, D. D.; Richardson, J. I. (Inventor)

    1984-01-01

    A hand held hydraulic cutting tool was developed which is particularly useful in deactivating ejection seats in military aircraft rescue operations. The tool consists primarily of a hydraulic system composed of a fluid reservoir, a pumping piston, and an actuator piston. Mechanical cutting jaws are attached to the actuator piston rod. The hydraulic system is controlled by a pump handle. As the pump handle is operated the actuator piston rod is forced outward and thus the cutting jaws are forced together. The frame of the device is a flexible metal tubing which permits easy positioning of the tool cutting jaws in remote and normally inaccessible locations. Bifurcated cutting edges ensure removal of a section of the tubing or cable to thereby reduce the possibility of accidental reactivation of the tubing or cable being severed.

  15. The N-Terminus of Human Lactoferrin Displays Anti-biofilm Activity on Candida parapsilosis in Lumen Catheters.

    Science.gov (United States)

    Fais, Roberta; Di Luca, Mariagrazia; Rizzato, Cosmeri; Morici, Paola; Bottai, Daria; Tavanti, Arianna; Lupetti, Antonella

    2017-01-01

    Candida parapsilosis is a major cause of hospital-acquired infection, often related to parenteral nutrition administered via catheters and hand colonization of health care workers, and its peculiar biofilm formation ability on plastic surfaces. The mortality rate of 30% points to the pressing need for new antifungal drugs. The present study aimed at analyzing the inhibitory activity of the N-terminal lactoferrin-derived peptide, further referred to as hLF 1-11, against biofilms produced by clinical isolates of C. parapsilosis characterized for their biofilm forming ability and fluconazole susceptibility. hLF 1-11 anti-biofilm activity was assessed in terms of reduction of biofilm biomass, metabolic activity, and observation of sessile cell morphology on polystyrene microtiter plates and using an in vitro model of catheter-associated C. parapsilosis biofilm production. Moreover, fluctuation in transcription levels of genes related to cell adhesion, hyphal development and extracellular matrix production upon peptide exposure were evaluated by quantitative real time RT-PCR. The results revealed that hLF 1-11 exhibits an inhibitory effect on biofilm formation by all the C. parapsilosis isolates tested, in a dose-dependent manner, regardless of their fluconazole susceptibility. In addition, hLF 1-11 induced a statistically significant dose-dependent reduction of preformed-biofilm cellular density and metabolic activity at high peptide concentrations only. Interestingly, when assessed in a catheter lumen, hLF 1-11 was able to induce a 2-log reduction of sessile cell viability at both the peptide concentrations used in RPMI diluted in NaPB. A more pronounced anti-biofilm effect was observed (3.5-log reduction) when a 10% glucose solution was used as experimental condition on both early and preformed C. parapsilosis biofilm. Quantitative real time RT-PCR experiments confirmed that hLF 1-11 down-regulates key biofilm related genes. The overall findings suggest hLF 1-11 as a

  16. A new evaluation of the upper esophageal sphincter using the functional lumen imaging probe: a preliminary report.

    LENUS (Irish Health Repository)

    Regan, J

    2012-03-06

    Objective and reliable evaluation of upper esophageal sphincter (UES) opening during swallowing based on videofluoroscopy and pharyngeal manometry challenges dysphagia clinicians. The functional lumen imaging probe (FLIP) is a portable tool based on impedance planimetry originally designed to measure esophogastric junction compliance. It is hypothesized that FLIP can evaluate UES distensibility, and can provide UES diameter and pressure measurements at rest, during swallowing, and during voluntary maneuvers. Eleven healthy adult subjects consented to FLIP evaluation. The probe was inserted transorally, and the balloon was positioned across the UES. Two 20-mL ramp distensions were completed. Changes in UES diameter and intraballoon pressure were measured during dry and 5-mL liquid swallows, and during voluntary swallow postures and maneuvers employed in clinical practice. The protocol was completed by 10 of 11 healthy subjects. Mean intraballoon pressure increased throughout 5-mL (5.8 mmHg; -4.5-18.6 mmHg), 10-mL (8.7 mmHg; 2.3-28.5 mmHg), 15-mL (17.3 mmHg; 9.5-34.8 mmHg), and 20-mL (31.2 mmHg; 16-46.3 mmHg) balloon volumes. Mean resting UES diameter (4.9 mm) increased during dry swallows (9.2 mm) and 5-mL liquid swallows (7.7 mm). Mean UES diameter increased during 5-mL liquid swallows with head turn to right (8.1 mm) and left (8.3 mm), chin tuck (8.4 mm), effortful swallow (8.5 mm), Mendelsohn maneuver (8.1 mm), and supraglottic swallow (7.8 mm). FLIP was safely inserted and distended in the UES, and provided useful quantitative data regarding UES distensibility and UES diameter changes during swallowing maneuvers. Further research is being conducted to explore the role of FLIP in UES evaluation.

  17. Observing Double Stars

    Science.gov (United States)

    Genet, Russell M.; Fulton, B. J.; Bianco, Federica B.; Martinez, John; Baxter, John; Brewer, Mark; Carro, Joseph; Collins, Sarah; Estrada, Chris; Johnson, Jolyon; Salam, Akash; Wallen, Vera; Warren, Naomi; Smith, Thomas C.; Armstrong, James D.; McGaughey, Steve; Pye, John; Mohanan, Kakkala; Church, Rebecca

    2012-05-01

    Double stars have been systematically observed since William Herschel initiated his program in 1779. In 1803 he reported that, to his surprise, many of the systems he had been observing for a quarter century were gravitationally bound binary stars. In 1830 the first binary orbital solution was obtained, leading eventually to the determination of stellar masses. Double star observations have been a prolific field, with observations and discoveries - often made by students and amateurs - routinely published in a number of specialized journals such as the Journal of Double Star Observations. All published double star observations from Herschel's to the present have been incorporated in the Washington Double Star Catalog. In addition to reviewing the history of visual double stars, we discuss four observational technologies and illustrate these with our own observational results from both California and Hawaii on telescopes ranging from small SCTs to the 2-meter Faulkes Telescope North on Haleakala. Two of these technologies are visual observations aimed primarily at published "hands-on" student science education, and CCD observations of both bright and very faint doubles. The other two are recent technologies that have launched a double star renaissance. These are lucky imaging and speckle interferometry, both of which can use electron-multiplying CCD cameras to allow short (30 ms or less) exposures that are read out at high speed with very low noise. Analysis of thousands of high speed exposures allows normal seeing limitations to be overcome so very close doubles can be accurately measured.

  18. Formation of double layers

    International Nuclear Information System (INIS)

    Leung, P.; Wong, A.Y.; Quon, B.H.

    1981-01-01

    Experiments on both stationary and propagating double layers and a related analytical model are described. Stationary double layers were produced in a multiple plasma device, in which an electron drift current was present. An investigation of the plasma parameters for the stable double layer condition is described. The particle distribution in the stable double layer establishes a potential profile, which creates electron and ion beams that excite plasma instabilities. The measured characteristics of the instabilities are consistent with the existence of the double layer. Propagating double layers are formed when the initial electron drift current is large. Ths slopes of the transition region increase as they propagate. A physical model for the formation of a double layer in the experimental device is described. This model explains the formation of the low potential region on the basis of the space charge. This space charge is created by the electron drift current. The model also accounts for the role of ions in double layer formation and explains the formation of moving double layers. (Auth.)

  19. Biocompatibility of Different Nerve Tubes

    Science.gov (United States)

    Stang, Felix; Keilhoff, Gerburg; Fansa, Hisham

    2009-01-01

    Bridging nerve gaps with suitable grafts is a major clinical problem. The autologous nerve graft is considered to be the gold standard, providing the best functional results; however, donor site morbidity is still a major disadvantage. Various attempts have been made to overcome the problems of autologous nerve grafts with artificial nerve tubes, which are “ready-to-use” in almost every situation. A wide range of materials have been used in animal models but only few have been applied to date clinically, where biocompatibility is an inevitable prerequisite. This review gives an idea about artificial nerve tubes with special focus on their biocompatibility in animals and humans.

  20. Working session 3: Tubing integrity

    International Nuclear Information System (INIS)

    Cueto-Felgueroso, C.; Strosnider, J.

    1997-01-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group's discussions on these subjects, including conclusions and recommendations, are summarized in this article

  1. The Sealed Tube Neutron Generator

    International Nuclear Information System (INIS)

    Tunnell, L.N.; Beyerle, A.; Durkee, R.; Headley, G.; Hurley, P.

    1992-01-01

    A Sealed Tube Neutron Generator (STNG) has been designed and tested at Special Technologies Laboratories (STL) in Santa Barbara, California. Unlike similar tubes that have been used for years in other applications, e.g., by the oil well logging industry, the present device was designed primarily to be part of the Associated Particle Imaging (API) system. Consequently, the size and quality of the neutron spot produced by the STNG is of primary importance. Results from initial measurements indicate that performance goals are satisfied

  2. YouTube and Facebook

    DEFF Research Database (Denmark)

    Robertson, Scott P.; Vatrapu, Ravi; Medina, Richard

    This paper examines the links to YouTube from the Facebook “walls” of Barack Obama, Hillary Clinton, and John McCain over two years prior to the 2008 U.S. Presidential election. User-generated linkage patterns show how participants in these politically-related social networking dialogues used...... online video to make their points. We show a strong integration of the Web 2.0 and new media technologies of social networking and online video. We argue that political discussion in social networking environments can no longer be viewed as primarily textual, and that neither Facebook nor YouTube can...

  3. Core barrel inner tube lifter

    Energy Technology Data Exchange (ETDEWEB)

    Jeffers, J P

    1968-07-16

    A core drill with means for selectively lifting a core barrel inner tube consists of a lifting means connected to the core barrel inner tube assembly. It has a closable passage to permit drilling fluid normally to pass through it. The lifting means has a normally downward facing surface and a means to direct drilling fluid pressure against that surface so that on closure of the passage to fluid flow, the pressure of the drilling fluid is caused to act selectively on it. This causes the lifting means to rise and lift the core barrel. (7 claims)

  4. Opposed slant tube diabatic sorber

    Science.gov (United States)

    Erickson, Donald C.

    2004-01-20

    A sorber comprised of at least three concentric coils of tubing contained in a shell with a flow path for liquid sorbent in one direction, a flow path for heat transfer fluid which is in counter-current heat exchange relationship with sorbent flow, a sorbate vapor port in communication with at least one of sorbent inlet or exit ports, wherein each coil is coiled in opposite direction to those coils adjoining it, whereby the opposed slant tube configuration is achieved, with structure for flow modification in the core space inside the innermost coil.

  5. The FINUDA straw tube detector

    CERN Document Server

    Zia, A; Bertani, M; Bianco, S; Fabbri, Franco Luigi; Gianotti, P; Giardoni, M; Lucherini, V; Mecozzi, A; Pace, E; Passamonti, L; Qaiser, N; Russo, V; Tomassini, S; Sarwar, S; Serdyouk, V

    2001-01-01

    An array of 2424 2.6- m-long, 15- mm-diameter mylar straw tubes, arranged in two axial and four stereo layers, has been assembled at National Laboratories of Frascati of INFN for the FINUDA experiment. The array covers a cylindrical tracking surface of 18 m sup 2 and provides coordinate measurement in the drift direction and along the wire with a resolution of the order of 100 and 300 mu m, respectively. The array has finished the commissioning phase and tests with cosmic rays are underway. The status straw tubes array and a very preliminary result from cosmic rays test are summarized in this work.

  6. The FINUDA straw tube detector

    International Nuclear Information System (INIS)

    Zia, A.; Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F.L.; Gianotti, P.; Giardoni, M.; Lucherini, V.; Mecozzi, A.; Pace, E.; Passamonti, L.; Qaiser, N.; Russo, V.; Tomassini, S.; Sarwar, S.; Serdyouk, V.

    2001-01-01

    An array of 2424 2.6- m-long, 15- mm-diameter mylar straw tubes, arranged in two axial and four stereo layers, has been assembled at National Laboratories of Frascati of INFN for the FINUDA experiment. The array covers a cylindrical tracking surface of 18 m 2 and provides coordinate measurement in the drift direction and along the wire with a resolution of the order of 100 and 300 μm, respectively. The array has finished the commissioning phase and tests with cosmic rays are underway. The status straw tubes array and a very preliminary result from cosmic rays test are summarized in this work

  7. The FINUDA straw tube detector

    Science.gov (United States)

    Zia, A.; Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F. L.; Gianotti, P.; Giardoni, M.; Lucherini, V.; Mecozzi, A.; Pace, E.; Passamonti, L.; Qaiser, N.; Russo, V.; Tomassini, S.; Sarwar, S.; Serdyouk, V.

    2001-04-01

    An array of 2424 2.6- m-long, 15- mm-diameter mylar straw tubes, arranged in two axial and four stereo layers, has been assembled at National Laboratories of Frascati of INFN for the FINUDA experiment. The array covers a cylindrical tracking surface of 18 m 2 and provides coordinate measurement in the drift direction and along the wire with a resolution of the order of 100 and 300 μm, respectively. The array has finished the commissioning phase and tests with cosmic rays are underway. The status straw tubes array and a very preliminary result from cosmic rays test are summarized in this work.

  8. Control rod guide tube assemblies

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    A nuclear fuel assembly including sleeves telescoped over end portions of control rod guide tubes which bear against internal shoulders of the sleeves. Upper ends of the sleeves protrude beyond a control rod guide tube spider and are locked in place by means of a resilient cellular lattice or lock that is seated in mating grooves in the outer surfaces of the sleeves. A grapple is provided for disengaging the entire lock structure spider and associated washers, springs and a grill from the end of the fuel assembly in order to enable these components to be removed and subsequently replaced on the fuel assembly after inspection and repair. (UK)

  9. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  10. Mechanics of neurulation: From classical to current perspectives on the physical mechanics that shape, fold, and form the neural tube.

    Science.gov (United States)

    Vijayraghavan, Deepthi S; Davidson, Lance A

    2017-01-30

    Neural tube defects arise from mechanical failures in the process of neurulation. At the most fundamental level, formation of the neural tube relies on coordinated, complex tissue movements that mechanically transform the flat neural epithelium into a lumenized epithelial tube (Davidson, 2012). The nature of this mechanical transformation has mystified embryologists, geneticists, and clinicians for more than 100 years. Early embryologists pondered the physical mechanisms that guide this transformation. Detailed observations of cell and tissue movements as well as experimental embryological manipulations allowed researchers to generate and test elementary hypotheses of the intrinsic and extrinsic forces acting on the neural tissue. Current research has turned toward understanding the molecular mechanisms underlying neurulation. Genetic and molecular perturbation have identified a multitude of subcellular components that correlate with cell behaviors and tissue movements during neural tube formation. In this review, we focus on methods and conceptual frameworks that have been applied to the study of amphibian neurulation that can be used to determine how molecular and physical mechanisms are integrated and responsible for neurulation. We will describe how qualitative descriptions and quantitative measurements of strain, force generation, and tissue material properties as well as simulations can be used to understand how embryos use morphogenetic programs to drive neurulation. Birth Defects Research 109:153-168, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Bradycardia after Tube Thoracostomy for Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Yomi Fashola

    2018-01-01

    Full Text Available We present the case of an elderly patient who became bradycardic after chest tube insertion for spontaneous pneumothorax. Arrhythmia is a rare complication of tube thoracostomy. Unlike other reported cases of chest tube induced arrhythmias, the bradycardia in our patient responded to resuscitative measures without removal or repositioning of the tube. Our patient, who had COPD, presented with shortness of breath due to spontaneous pneumothorax. Moments after tube insertion, patient developed severe bradycardia that responded to Atropine. In patients requiring chest tube insertion, it is important to be prepared to provide cardiopulmonary resuscitative therapy in case the patient develops a life-threatening arrhythmia.

  12. Overlapping double potential wells in a single optical microtube cavity with vernier-scale-like tuning effect

    Energy Technology Data Exchange (ETDEWEB)

    Madani, A.; Schmidt, O. G. [Institute for Integrative Nanosciences, IFW Dresden, Helmholtzstr. 20, 01069 Dresden (Germany); Material Systems for Nanoelectronics, Chemnitz University of Technology, Reichenhainer Str. 70, 09107 Chemnitz (Germany); Bolaños Quiñones, V. A.; Ma, L. B., E-mail: l.ma@ifw-dresden.de; Jorgensen, M. R. [Institute for Integrative Nanosciences, IFW Dresden, Helmholtzstr. 20, 01069 Dresden (Germany); Miao, S. D. [Anhui Key Lab of Controllable Chemical Reaction and Material Chemical Engineering, School of Chemical Engineering, Hefei University of Technology, Tunxi Road. 193, Hefei, Anhui 230009 (China)

    2016-04-25

    Spatially and temporally overlapping double potential wells are realized in a hybrid optical microtube cavity due to the coexistence of an aggregate of luminescent quantum dots embedded in the tube wall and the cone-shaped tube's geometry. The double potential wells produce two independent sets of optical modes with different sets of mode numbers, indicating phase velocity separation for the modes overlapping at the same frequency. The overlapping mode position can be tuned by modifying the tube cavity, where these mode sets shift with different magnitudes, allowing for a vernier-scale-like tuning effect.

  13. Overlapping double potential wells in a single optical microtube cavity with vernier-scale-like tuning effect

    International Nuclear Information System (INIS)

    Madani, A.; Schmidt, O. G.; Bolaños Quiñones, V. A.; Ma, L. B.; Jorgensen, M. R.; Miao, S. D.

    2016-01-01

    Spatially and temporally overlapping double potential wells are realized in a hybrid optical microtube cavity due to the coexistence of an aggregate of luminescent quantum dots embedded in the tube wall and the cone-shaped tube's geometry. The double potential wells produce two independent sets of optical modes with different sets of mode numbers, indicating phase velocity separation for the modes overlapping at the same frequency. The overlapping mode position can be tuned by modifying the tube cavity, where these mode sets shift with different magnitudes, allowing for a vernier-scale-like tuning effect.

  14. Welding the CNGS decay tube

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    3.6 km of welds were required for the 1 km long CERN Neutrinos to Gran Sasso (CNGS) decay tube, in which particles produced in the collision with a proton and a graphite target will decay into muons and muon neutrinos. Four highly skilled welders performed this delicate task.

  15. Tube in shell heat exchangers

    International Nuclear Information System (INIS)

    Hayden, O.; Willby, C.R.; Sheward, G.E.; Ormrod, D.T.; Firth, G.F.

    1980-01-01

    An improved tube-in-shell heat exchanger to be used between liquid metal and water is described for use in the liquid metal coolant system of fast breeder reactors. It is stated that this design is less prone to failures which could result in sodium water reactions than previous exchangers. (UK)

  16. Working session 1: Tubing degradation

    International Nuclear Information System (INIS)

    Kharshafdjian, G.; Turluer, G.

    1997-01-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to open-quotes develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.close quotes Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym open-quotes MESSclose quotes by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed

  17. Kundt's Tube Experiment Using Smartphones

    Science.gov (United States)

    Parolin, Sara Orsola; Pezzi, Giovanni

    2015-01-01

    This article deals with a modern version of Kundt's tube experiment. Using economic instruments and a couple of smartphones, it is possible to "see" nodes and antinodes of standing acoustic waves in a column of vibrating air and to measure the speed of sound.

  18. OurTube / David Talbot

    Index Scriptorium Estoniae

    Talbot, David

    2009-01-01

    USA California Ülikooli töötajate Abram Stern'i ja Michael Dale'i poolt 2005. a. algatatud USA kongressis peetud kõnede videoremiksidest ja nende poolt loodud veebisaidist Metavid.org. Ka YouTube keskkonnast ja wikipedia katsetustest muuta oma keskkond multimeedialisemaks

  19. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  20. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...