WorldWideScience

Sample records for double contrast barium

  1. Double contrast barium meal and acetylcysteine

    International Nuclear Information System (INIS)

    Kinnunen, J.; Pietilae, J.; Ahovuo, J.; Mankinen, P.; Tervahartiala, P.

    1989-01-01

    In a prospective double blind study, acetylcysteine, a local and systemic respiratory tract mucolytic agent, or a placebo, were given to 100 patients prior to a double contrast barium meal to decrease the gastric mucus viscosity and to make the mucus layer thinner, in order to permit barium to outline the furrows surrounding the areae gastricae instead of the overlying thick mucus. However, acetylcysteine failed to improve either visualization of the areae gastricae or the general quality of the double contrast barium meal. (orig.)

  2. Air (CO2) double-contrast barium enteroclysis.

    Science.gov (United States)

    Maglinte, Dean D T; Kohli, Marc D; Romano, Stefania; Lappas, John C

    2009-09-01

    In the 1980s and 1990s in North America and Europe, air (CO(2)) double-contrast barium enteroclysis took a back seat to biphasic methylcellulose double-contrast enteroclysis in the investigation of small-bowel diseases. The widespread application of capsule endoscopy in the 21st century has identified a number of limitations of radiologic examinations in the investigation of mucosal diseases of the small intestine. Evidence-based studies comparing barium, computed tomographic (CT), and magnetic resonance (MR) enteroclysis have shown that in spite of improvements in small-bowel examination methods using CT and MR, barium examinations remain superior in the depiction of mucosal abnormalities, particularly the apthoid lesions of early Crohn disease. Barium small-bowel examinations have been recommended in the patient with a negative CT or MR enteroclysis study where the pretest probability of Crohn disease is high. A recent prospective comparison of methylcellulose double-contrast barium enteroclysis to capsule endoscopy with review of the literature has shown that air enteroclysis depicts mucosal details better than does methylcellulose double-contrast enteroclysis because of the "washout" effect of methylcellulose on superficial mucosal features. Recent articles have shown that air enteroclysis compares favorably with wireless capsule endoscopy and double-balloon endoscopy in the diagnosis of mucosal abnormalities of the small bowel. This article describes the authors' technique of performing air double-contrast enteroclysis, its clinical indications, and its pitfalls.

  3. A new double contrast barium enema

    International Nuclear Information System (INIS)

    Park, Jun Sang; Cho, Won Sik; Lee, Sung Woo; Lee, Mun Gyu; Jeon, Jeong Dong; Jaun, Woo Ki; Han, Chung Yul

    1987-01-01

    A new technic of the barium enema was proposed for the better colonic double contrast study with the average 204ml of 50w/v% barium, applied to 109 serial patients. The barium was introduced to sigmoid colon, and then pushed to a mid transverse colon by the air insufflation through an enema syringe, a new device. An advance to cecum is accomplished by the air insufflation and/or the position change of the patient. The barium transfer method was developed for the best spot film exposure, through colon, by the position change of the patient, the tilting of the x-ray table and the air insufflation with the enema syringe. The mean angle of the x-ray table tilted was -10 .deg. at the beginning the barium enema till the barium sent past the splenic flexure, -15 . deg. for the best lateral view of rectum and -18 .deg. for the bet prone PA view of rectosigmoid colon. This was a simple, better and economic double contrast barium enema for the cooperative patients

  4. Effect of sodium bicarbonate pretreatment on barium coating of mucosa during double contrast barium meal

    International Nuclear Information System (INIS)

    Kinnunen, J.; Toetterman, S.; Kaila, R.; Pietilae, J.; Linden, H.; Tervahartiala, P.

    1983-01-01

    The radiographic pattern of the areae gastricae is produced by barium lying in the intersecting furrows of the gastric mucosal surface. However, if the mucus layer on the gastric mucosa is thick, it interferes with the barium coating of the areae gastricae during double contrast barium meal. As sodium bicarbonate decreases the viscosity of mucus and thus may make the gastric mucus layer thinner, it was evaluated as a pretreatment agent in a routine double contrast upper-gastrointestinal study to improve the visualization of the areae gastricae. In a single blind study, 53 of 106 patients took sodium bicarbonate water mixtures at bedtime the day before and on the morning of the examination. According to the results of the present study mucolysis induced by the used doses of sodium bicarbonate does not significantly affect micromucosal visualization during double-contrast barium meal. (orig.) [de

  5. Effect of sodium bicarbonate pretreatment on barium coating of mucosa during double contrast barium meal

    Energy Technology Data Exchange (ETDEWEB)

    Kinnunen, J.; Toetterman, S.; Kaila, R.; Pietilae, J.; Linden, H.; Tervahartiala, P.

    1983-08-01

    The radiographic pattern of the areae gastricae is produced by barium lying in the intersecting furrows of the gastric mucosal surface. However, if the mucus layer on the gastric mucosa is thick, it interferes with the barium coating of the areae gastricae during double contrast barium meal. As sodium bicarbonate decreases the viscosity of mucus and thus may make the gastric mucus layer thinner, it was evaluated as a pretreatment agent in a routine double contrast upper-gastrointestinal study to improve the visualization of the areae gastricae. In a single blind study, 53 of 106 patients took sodium bicarbonate water mixtures at bedtime the day before and on the morning of the examination. According to the results of the present study mucolysis induced by the used doses of sodium bicarbonate does not significantly affect micromucosal visualization during double-contrast barium meal.

  6. On film quality in barium-air double contrast colon study

    International Nuclear Information System (INIS)

    Rhu, Sang Hyung; Rhee, Jae Ho; Kim, Hai Sung; Cheung, Hwan

    1984-01-01

    The colon double contrast study provides valuable diagnostic information by means of appropriate control of Kvp and mAa when making double contrast image by injecting air into the colon after coating the colon wall by appropriately diluted Barium solution. The following experiments were performed the results of which allowed to improve the quality of film in barium-air double contrast colon study: (1) Do the pictures have uniform density when measured with a densitometer from three measuring points established in the picture by changing Kvp and mAs depending on the thickness of the patient? (2) Is the quality of the picture improved by being compensated from the adjacent area when using a wedge filter in routine check lateral decubitus and erect view? (3) What is the optimum dilution of barium solution which gives the best result for colon wall coating? The above experiments revealed that as the patient's thickness increased, it should be considered to increase mAs as well as Kvp and a wedge filter could give diagnostically very informative pictures in routine-check lateral decubitus and erect view. And 70-80% solution of Barium-water mixture provided the best quality of double contrast image

  7. Granulomatous colitis: findings on double contrast barium enema and follow-up studies

    International Nuclear Information System (INIS)

    Song, Jong Gi; Han, Joon Koo; Kim, Seung Hoon; Choo, Sung Wook; Kim, Seung Cheol; Choi, Byung Ihn

    1995-01-01

    To evaluate the radiologic findings of granulomatous colitis on double contrast barium enema and changes on follow-up studies. Serial double contrast barium enema of six patients with granulomatous colitis confirmed by endoscopic biopsy were reviewed. We analyzed the radiologic findings and their follow-up changes, including aphthous ulcers, lymphoid hyperplasia, deep ulcers, cobble stone appearance, geographic ulcers, asymmetric involvement of ulcers, skip lesions, sinus tract, fistula formation, pseudosacculation, focal stricture, and small bowel involvement. Pretreatment double contrast barium enema findings were aphthous ulcers in five patients, deep ulcer in six, cobble stone appearance in five, longitudinal geographic ulcers in two, fistulas in one, pseudosacculations in two, focal stricture in one, and pseudopolyps in six. Also, anal ulcers were observed in two patients, asymmetric involvement of ulcers in three, skip lesions in four, and small bowel involvement in five in five patients proved to have inactive disease after treatment, aphthous ulcers and deep ulcers disappeared. Geographic ulcers of two patients and anal ulcer of one patients decreased in size or depth. Pseudosacculation in one patient disappeared. Pseudopolyps decreased in two patients, increased in one, and decreased after increase in two. One patient whose disease remained active after treatment showed maintenance or increase of ulcers or fistula. And their pseudosacculation or focal stricture unchanged and pseudopolyps decreased. The major radiologic findings of chronic granulomatous colitis on double contrast barium enema are aphthous ulcer, deep ulcer, cobble stone appearance, discontinuity of the lesion and coexistence of ulcers and pseudopolyps. And, double contrast barium enema is good follow-up modality because its findings correlate with clinical course of the granulomatous colitis after treatment

  8. Early colon cancer : findings on double contrast barium enema

    International Nuclear Information System (INIS)

    Kim, Seung Kwon; Lim, Jae Hoon; Lee, Soon Jin; Lim, Hyo Keun

    1998-01-01

    The purpose of this study is to describe the radiologic findings of early colon cancer on double-contrast barium enema. We retrospectively reviewed the double-contrast barium enemas of eight patients (M:F = 6:2; mean age : 67 yrs; range : 48-77 yrs) who were pathologically proven to be early colon cancer. The location, size and gross morphology of lesions was evaluated using double-contrast barium enema, while depth of invasion, degree of differentiation, precancerous lesions and lymph node metastasis were evaluated histopathologically. Early colon cancer was found in the rectum (n=4), sigmoid colon (n=3) and ascending colon (n=1). The size of mass ranged from 2.3 ∼ 8.3 (mean, 4.6) cm. And the polypoid type was most common (n=7); this was subdivided into sessile (Is, n=5), semipedunculated (Isp, n=1) and pedunculated type (Ip, n=1). Another mass was a sessile polypoid combined with a flat depressed lesion. In eight cases, four cancers were confined to the mucosa, while the remaining four had infiltrated the submucosa. Most cancers arose from villous and villotubular adenoma. All cases were well-differentiated adenocarcinoma and no metastasis to lymph nodes had occurred. In early colon cancer, lesions were mainly polypoid and large. Most arose from villous and villotubular adenoma. (author). 19 refs., 1 tab., 3 figs

  9. Sensitivity of single and double contrast barium enema in the detection of colorectal carcinoma

    International Nuclear Information System (INIS)

    Myllylae, V.; Paeivansalo, M.; Laitinen, S.; Oulu Univ.

    1984-01-01

    The preoperative barium enema of the 188 colorectal carcinoma patients operated at the Oulu University Central Hospital (Finland) during 1977-1982 were examined retrospectively. Altogether 112 single contrast studies and 87 double contrast studies had been made on these patients. The single contrast barium enemas had resulted in a correct diagnosis of colorectal carcinoma in 93 cases (sensitivity 83%). The correct diagnosis in the double contrast studies numbered 71 (sensitivity 82%). Most of the overlooked carcinomas were located in the caecum, in the sigmoid or the rectum. Most of the errors made in the single contrast studies were due to detection errors and poor evacuation. The most common failures in double contrast enemas were detection errors and nonvisualisation of the sigmoid. The authors recommend use of the double contrast technique and suggest that the two methods of barium enema be used to complement each other. A false negative diagnosis delayed the operation of the colorectal carcinoma patients by 2.2 months (median). (orig.) [de

  10. Double contrast with technique of Insufflated Barium Meal in the radiological study of the esophagus

    International Nuclear Information System (INIS)

    Gallina, F.; Piga, V.; Gallina, M.S.

    1985-01-01

    The results are reported of the esophagus double contrast examination with Insufflated Barium Meal technique as first part of the routine upper digestive system radiological examination. This technique gives good double contrast without those artifacts using effervescent powders and without modifying the normal radiological alimentary tract examination established way. The double contrast is administered by a special container with a built-in mouthpiece which allows the simultaneous ingestion of barium suspension and air. The esophageal mucosa can be examined as far as the distal tract where frequently the barium contrast stops using different techniques. Good results in 90% of patients have been obtained. The early detection of inflammatory and tumoral lesions has taken particular advantage in patients sometimes asymptomatic

  11. Double contrast with technique of Insufflated Barium Meal in the radiological study of the esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Gallina, F; Piga, V; Gallina, M.S. and others

    1985-01-01

    The results are reported of the esophagus double contrast examination with Insufflated Barium Meal technique as first part of the routine upper digestive system radiological examination. This technique gives good double contrast without those artifacts using effervescent powders and without modifying the normal radiological alimentary tract examination established way. The double contrast is administered by a special container with a built-in mouthpiece which allows the simultaneous ingestion of barium suspension and air. The esophageal mucosa can be examined as far as the distal tract where frequently the barium contrast stops using different techniques. Good results in 90% of patients have been obtained. The early detection of inflammatory and tumoral lesions has taken particular advantage in patients sometimes asymptomatic.

  12. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  13. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  14. Routine filtration for decubitus radiography during double contrast barium enema examinations

    International Nuclear Information System (INIS)

    Camellini, V.; Abelli, P.; Marconi, G.

    1987-01-01

    A wedge-shaped plexiglass compensation filter for use in lateral decubitus radiographs of double contrast barium enema examinations has been designed. This filter, which has been used since February 1985, was compared with a second plexiglass filter, made by E-Z-EM. Voltage and amperage were kept contrast. Two different experiments were conducted in order to demonstrate the benefits of routine use of this compensation filter. First, the changes in skin dose were assessed using an ionization chamber on phantom. Secondly, three radiologists examined a series of 80 consecutive barium enemas without knowing which had been performed using the new filter. Out of the 70 examinations they considered excellent, as many as 45 had been performed with the new filter. Personal experience and the studies described show that the use of a compensation filter improves the accuracy and thus the diagnostic quality of the examinations as it enhances the detail of the anatomic structure of the colon; moreover the filter reduces skin exposure by up to 73.1% (EZ-E-EM filter 47.3%) and, at the same time, less radiographic films are needed. Routine use of a plexiglass compensation filter in lateral decubitus radiographs while performing a double contrast barium enema examination, is strongly recommended especially in obese patients

  15. A radiologic evaluation of bladder tumors on barium air double contrast cystography and triple-fractionated cystography

    International Nuclear Information System (INIS)

    Hur, W. J.; Jang, H. Y.; Sol, C. H.; Kim, B. S.

    1984-01-01

    Clinically bladder tumors can be easily diagnosed on cystoscopic examination and biopsy in the patients with silent hematuria, terminal dribbling and dysuria. But for the evaluation of the extent of tumor invasion, the authors performed both barium-air double contrast and triple-fractionated cystography on 16 patients suspected to be bladder tumor on cystoscopic examination in the radiologic department of B.N.U.H. from September 1982 to August 1983. The obtained results were summarized as follows. 1. On barium-air double contrast cystography and triple-fractionated cystography, 13 cases were concluded as bladder tumor, and 3 cases were consistent with the findings of chronic inflammation out of the total 16 cases. 2. After operation of 15 cases, 12 cases were confirmed pathologically as transitional cell carcinoma, 1 case as prostatic hypertrophy, and 2 cases as chronic inflammation. Remaining one was biopsied on cystoscopic examination, and confirmed as chronic inflammation. 3. Among 9 cases of transitional cell carcinoma having the evidence of muscle invasion on triple- fractionated cystography, 8 cases were confirmed as more than stage B 1 on pathologic study, and the other as chronic inflammation. 4. In detecting multiplicity, presence of ulceration, and evaluation of nature of tumor surface, barium- air double contrast cystogrpahy was more excellent than cystoscopic results. 5. Cases presenting both ulceration and cauliflower appearance on barium- air double contrast cystography was more than grade III on microscopic evaluation. 6. In conclusion, the authors considers the barium-air double contrast and triple-fractionated cystography are easy to perform, reasonable in price and have relatively high accuracy in tumor detection, staging and grading.

  16. Comparative evaluation of positive contrast and double contrast gastrography in dogs

    International Nuclear Information System (INIS)

    Dileepkumar, K.M.; Rajankutty, K.; Sarada, Amma T.; Devanand, C.B.; Vijayan, N.

    2012-01-01

    A contrast radiography of stomach with oral barium sulphate suspension 25% (5 mL/kg b.wt positive contrast) and double contrast with oral barium sulphate 25% (3 mL/kg b.wt) followed by air (2 to 10 mL/kg b.wt, negative contrast) was done on six dogs to study the affections of stomach. Contrast radiography using barium sulphate alone was found satisfactory to identify most of the lesions of the stomach. Double contrast radiography using barium sulphate and air, required sedation to control the animals for proper administration. For the diagnosis of mucosal lesions, double contrast radiography was better than barium sulphate alone. Key words: Barium, Contrast radiography, Dog, Double contrast, Stomach

  17. Radiographer and radiologist perception error in reporting double contrast barium enemas: A pilot study

    International Nuclear Information System (INIS)

    Booth, Alison M.; Mannion, Richard A.J.

    2005-01-01

    Purpose: The practice of radiographers performing double contrast barium enemas (DCBE) is now widespread and in many centres the radiographer's opinion is, at least, contributing to a dual reporting system [Bewell J, Chapman AH. Radiographer performed barium enemas - results of a survey to assess progress. Radiography 1996;2:199-205; Leslie A, Virjee JP. Detection of colorectal carcinoma on double contrast barium enema when double reporting is routinely performed: an audit of current practice. Clin Radiol 2001;57:184-7; Culpan DG, Mitchell AJ, Hughes S, Nutman M, Chapman AH. Double contrast barium enema sensitivity: a comparison of studies by radiographers and radiologists. Clin Radiol 2002;57:604-7]. To ensure this change in practice does not lead to an increase in reporting errors, this study aimed to compare the perception abilities of radiographers with those of radiologists. Methods: Three gastro-intestinal (GI) radiographers and three consultant radiologists independently reported on a selection of 50 DCBE examinations, including the level of certainty in their comments for each examination. A blinded comparison of the results with an independent 'standard report' was recorded. Results: The results demonstrate there was no significant difference in perception error for any of the levels of certainty, for single reporting, for double reading by a radiographer/radiologist or by two radiologists. Conclusions: The study shows that radiographers can perceive abnormalities on DCBE at similar sensitivities and specificities as radiologists. While the participants in the study may be typical of a district general hospital, the nature of the study gives it limited external validity. As a pilot, the results demonstrate that, with slight modification, the methodology could be used for a larger study

  18. Compensation filtration for decubitus radiography during double-contrast barium enema examinations

    International Nuclear Information System (INIS)

    Feczko, P.J.; Haggar, A.M.; Rauch, P.L.; Halpert, R.D.; Simms, S.M.

    1983-01-01

    Lateral decubitus images obtained during double-contrast barium enema examinations may be difficult to interpret because of the large difference in density between the various parts of the radiographs. Several types of filters are described which can be used to rectify this problem, thus improving the quality of the decubitus radiographs and achieving a slight reduction in radiation exposure

  19. Imaging assessment of the modified double contrast barium enema using carboxymethylcellulose on radiography and ultrasonography in dogs.

    Science.gov (United States)

    Choi, Mihyun; Lee, Namsoon; Kim, Junyoung; Yi, Kangjae; Jung, Joohyun; Yoon, Junghee; Choi, Mincheol

    2011-01-01

    A modified double contrast barium enema using carboxymethylcellulose was evaluated in beagle dogs and compared with dogs receiving a conventional barium enema. The experimental group was divided into three groups (1, 2, and 3) and given 30 ml/kg of different volume ratios of a barium vs. carboxymethylcellulose mixture. Each group underwent sonography following radiography. The volume ratio of one part barium to three parts carboxymethylcellulose was judged to be the optimal mixture, resulting in a general distribution of contrast and bowel radiolucency on radiographs and adequate postradiography sonography. The modified barium enema using carboxymethylcellulose is useful for assessing the general morphology and mucosal layers of the colon simultaneously on radiographs and ultrasonographs.

  20. Colorectal cancer: screening double-contrast barium enema examination in average-risk adults older than 50 years.

    Science.gov (United States)

    Kung, Justin W; Levine, Marc S; Glick, Seth N; Lakhani, Paras; Rubesin, Stephen E; Laufer, Igor

    2006-09-01

    To retrospectively determine the diagnostic yield of double-contrast barium enema examinations performed for colorectal cancer screening of neoplasms 1 cm or larger or advanced neoplastic lesions of any size in average-risk adults older than 50 years. The Institutional Review Board at the affiliated Veterans Affairs Medical Center approved this HIPAA-compliant study protocol and did not require informed consent from patients. Computerized databases revealed 276 double-contrast barium enema examinations performed for colorectal cancer screening in average-risk adults older than 50 years. Radiographic and pathologic reports were reviewed to determine the number of patients who had polypoid lesions 1 cm or larger, polyps smaller than 1 cm, or advanced neoplastic lesions of any size. Forty-five (16.3%) of the 276 patients underwent follow-up sigmoidoscopy or colonoscopy. Medical, endoscopic, and pathologic records were reviewed and compared with radiographic findings. The results of double-contrast barium enema examination revealed 74 (26.8%) of 276 patients with 104 polypoid lesions in the colon, including 32 patients (11.6%) with 41 polypoid lesions 1 cm or larger, 15 patients (5.4%) with 19 polyps 6-9 mm, and 27 patients (9.8%) with 44 polyps 5 mm or smaller. Endoscopy was performed in 24 (75%) of 32 patients, the results of which confirmed 23 (72%) of 32 radiographically diagnosed lesions 1 cm or larger in 16 (67%) of 24 patients. In two of these individuals, the polyps were hyperplastic. The remaining 14 patients had a total of 21 neoplastic lesions 1 cm or larger, including 11 tubular adenomas, seven tubulovillous adenomas, one villous adenoma with marked dysplasia, and two cancers. The diagnostic yield of screening double-contrast barium enema examination was 5.1% (14 of 276 patients) for neoplastic lesions 1 cm or larger and 6.2% (17 of 276 patients) for advanced neoplastic lesions of any size. Double-contrast barium enema examinations performed in average

  1. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis

    OpenAIRE

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-01-01

    Objectives The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. Design and setting 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups’ results. Fi...

  2. Prospective comparison of double contrast barium enema plus flexible sigmoidoscopy v colonoscopy in rectal bleeding: barium enema v colonoscopy in rectal bleeding.

    OpenAIRE

    Irvine, E J; O'Connor, J; Frost, R A; Shorvon, P; Somers, S; Stevenson, G W; Hunt, R H

    1988-01-01

    Rectal bleeding often heralds serious colonic disease. The literature suggests that colonoscopy is superior to barium enema plus sigmoidoscopy, although no good comparative studies exist. Seventy one patients with overt rectal bleeding had prospectively flexible sigmoidoscopy, double contrast barium enema and colonoscopy completed independently. Against the gold standard, the sensitivity and specificity of colonoscopy were 0.69 and 0.78 respectively for a spectrum of colonic lesions, while fo...

  3. Elevated Z line: a new sign of Barrett's esophagus on double-contrast barium esophagograms.

    Science.gov (United States)

    Levine, Marc S; Ahmad, Nuzhat A; Rubesin, Stephen E

    2015-01-01

    We describe an elevated Z line as a new radiographic sign of Barrett's esophagus characterized by a transversely oriented, zigzagging, barium-etched line extending completely across the circumference of the midesophagus. An elevated Z line is rarely seen in other patients, so this finding should be highly suggestive of Barrett's esophagus on double-contrast barium esophagograms. If the patient is a potential candidate for surveillance, endoscopy and biopsy should be performed to confirm the presence of Barrett's esophagus. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Primary double contrast study of the colon with citrate-sorbitol-barium suspension in the diagnosis of chronic colitis

    International Nuclear Information System (INIS)

    Sidorov, V.S.

    1991-01-01

    X-ray investigation of the colon was conducted in 292 patients with clinically diagnosed chronic colitis: standard 3-phase irrigoscopy-in 189 patients and a primary double contrast study of the colon with citrate-sorbitol-barium suspenzion - in 103. Basing on X-ray and morphological findings, the diagnosis was confirmed in 128 patients of the 1st group (68.2 %) and in 89 patients of the 2nd group (86 %). The primary double contrast study of the colon was found more effective as it permitted the detection of elements of the mucosal microcontours: transversal strips, not coinciding with haustration, focal granularity, diffuse granularity, small barium suspension depots or niches, nodular granularity. It permitted the recommendation of the method for a wide clinical use

  5. The effect of timing of intravenous muscle relaxant on the quality of double-contrast barium enema

    International Nuclear Information System (INIS)

    Elson, E.M.; Elson, E.M.; Campbell, D.M.; Halligan, S.; Shaikh, I.; Davitt, S.; Bartram, C.I.

    2000-01-01

    AIM: To determine whether the timing of buscopan administration during double-contrast barium enema examination (DCBE) affects diagnostic quality. MATERIALS AND METHODS: In a prospective setting, 100 consecutive adult out-patients referred for DCBE received 20 mg buscopan (hyoscine-N-butylbromide) intravenously, either before infusion of barium suspension (Group A) or after barium infusion and gas insufflation (Group B). A subjective assessment of ease of contrast medium infusion was made at the time of examination and the films subsequently analysed by two radiologists unaware of the mode of relaxant administration, who noted the quality of mucosal coating and made subjective and objective measurements of segmental distension. RESULTS: There was no significant difference in screening times, infusion difficulty or colonic contrast medium coating between the two groups. Subjective assessment of distension of the caecum, ascending colon, transverse colon and rectum were not significantly different. Patients receiving intravenous relaxant after barium and gas infusion had less subjective descending (P = 0.05) and sigmoid (P = 0.04) colon distension, but there was no significant difference with respect to maximal bowel diameter in any of the segments measured. CONCLUSION: The timing of intravenous administration during DCBE is likely to have no significant effect on the diagnostic quality of the study. Elson, E.M. (2000)

  6. Early manifestation of Yersinia colitis demonstrated by the double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Aspestrand, F.

    1986-11-01

    A 19-year old female with a bloody, diarrheal illness of acute onset where Crohn's disease primarly was suspected is presented. The double-contrast barium enema revealed multiple, diffusely scattered aphthous erosions of the colonic mucosa: the rectum was scarcely affected. Biopsies taken by endoscopy demonstrated nonspecific inflammatory changes of the mucous membrane. However, routinely taken stool cultures revealed an infectious colitis due to Yersinia enterocolitica. Our case demonstrates the necessity to consider Yersinia enterocolitis in the radiographic differential diagnosis when the diagnosis of Crohn's disease or ulcerative colitis seems obvious.

  7. Correlation of double-contrast high-density barium enema, colonoscopy, and histology in children with special attention to disparities

    International Nuclear Information System (INIS)

    Stringer, D.A.; Sherman, P.M.; Jakowenko, N.

    1986-01-01

    Colonscopic and double-contrast high-density barium enema (DCBE) findings were correlated in 68 patients (39 boys and 29 girls) aged 6 months to 18 years (mean 11.6 years) evaluated over a 24-month period. There was excellent correlation in 53 patients (78.0%) and good correlation in another 3 (4.4%) who had identical diagnoses and only slightly differing extent of disease reported. In 2 of these, DCBE showed more extensive disease, confirmed histologically in 1. Distal colitis seen on colonoscopy as reddening and neovascularity was missed on DCBE in 6 patients. Colonoscopy and DEBE failed to show a polyp in 1 patient each. One patient who had a normal DCBE and colonoscopy demonstrated a histological abnormality, and 1 patient with an abnormality on histology and DCBE was normal on colonscopy. A disparity resulted from the time between procedures in 1 patient and observer error in another. This high correlation is far better than any previously reported in children, supporting the use of high-density barium sulfate and double-contrast barium enemas in pediatric patients. (orig.)

  8. Barium sulfate aspiration: Severe chemical pneumonia induced by a massive reflux of contrast medium during small bowel barium enema.

    Science.gov (United States)

    Zhang, Lin; Yang, Yi; Zhang, Ji; Zhou, Xiaowei; Dong, Hongmei; Zhou, Yiwu

    2015-08-01

    Barium contrast radiography is a conventional procedure aimed at revealing lesions of the alimentary tract using barium sulfate on X-ray irradiation. Although it is widely used in clinics, adverse effects and complications are observed, such as anaphylaxis, granuloma, fecalithes, abdomen-leaking, embolism, bacterial contamination, and aspiration. We report a case of death due to a massive barium sulfate aspiration resulted from an air-barium double contrast enema radiography. A 25-year-old female patient was hospitalized with symptoms of abdominal distention, nausea, vomiting and diarrhea for three days. A progressive respiratory distress presented only 1h after a small bowel air-barium double contrast enema. The patient died 11h later. The result of autopsy revealed the cause of death to be severe chemical pneumonitis induced by gastric fluid which was aspirated into her lungs. Barium sulfate is generally recognized to be chemically inert for the respiratory system, but a mixture of barium sulfate with gastric contents is fatal. Here we intend to suggest that, when determining the potential cause of death, medical examiners should consider a patient's status quo as well as the possible adverse effects and complications caused by the barium sulfate preparation during gastrointestinal radiography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Barium sulphate preparations for use in double contrast examination of the upper gastrointestinal tract

    International Nuclear Information System (INIS)

    Anderson, W.; Harthill, J.E.; James, W.B.; Montgomery, D.

    1980-01-01

    Physical properties relevant to upper gastrointestinal radiology have been compared for five barium sulphate preparations and related to radiographic results. Evaluation of particles (size and stability) and whole suspension (dispersibility and fluidity) resulted in ranking of the preparations generally in accord with that based on radiological experience in double contrast examinations of the stomach. Experiments with extirpated pig stomach revealed a tendency for large particles in a low viscosity barium sulphate suspension to settle in mucosal grooves. This is believed to contribute to good radiographic definition of both the areae gastricae and small lesions. Particle size is therefore important and susceptibility to flocculation, a possible cause of random change in size during use, was assessed by measuring particle electrophoretic mobility under varying conditions; quantitative differences in suspension flow and dispersibility were also demonstrated. Fluidity and dispersibility together with rapid sedimentation of suitably sized particles resistant to flocculation underlie the successful use of low viscosity high density barium sulphate suspensions. (U.K.)

  10. Development of a new high density (HD) barium meal (Falibaryt HD) for double contrast investigation of the stomach

    International Nuclear Information System (INIS)

    Dietze, R.

    1986-01-01

    During the development of a new double contrast barium meal barium sulfate preparations with various densities, additives and particle size distributions were tested. Phantoms made of leather, rubber and the opened stomachs of cows and pigs were used. A HD bariumsulfate suspension (200 - 250% W/V) of low viscosity and suitable grain size spectrum containing additives improving the adherence (e.g. natrium citrate) showed the best quality parameters for an optimal imaging of the fine mucosal relief. (author)

  11. Use of mucolytic agents and guaran HEPART (HP-7000) for the detection of mucosal villi in double contrast barium studies of the small intestine

    International Nuclear Information System (INIS)

    Desaga, J.F.

    1987-01-01

    It was the aim of this study to enhance the visualisation of mucosal villi by double contrast barium studies of the small bowel. Prior to the radiological examination a 2-day pretreatment with the mucolytic agents acetylcysteine or carbocisteine was effected. Double contrast studies were performed with a high-molecular fraction of guaran HEPART (HP-7000), a hydrocolloidal isolated from the seed endosperm of C. tetragonolobus added into contrast-medium and distention medium. Compared to double contrast studies without mucolytic therapy, this procedure results in a better transparency and demonstration of the mucosal villi shown by a granular pattern in the radiographs. High quality visualisation of intestinal villi was achieved in all patients studied. A 2-day pretreatment with carbocisteine or acetylcysteine and the use of guaran in the double contrast barium study of the small bowel results in a greatly enhanced visualisation of mucosal villi. (orig.) [de

  12. Double contrast barium enema: technique, indications, results and limitations of a conventional imaging methodology in the MDCT virtual endoscopy era.

    Science.gov (United States)

    Rollandi, Gian Andrea; Biscaldi, Ennio; DeCicco, Enzo

    2007-03-01

    The double contrast barium enema of the colon continues to be a diffused conventional radiological technique and allows for the diagnosis of neoplastic and inflammatory pathology. After the '70s, a massive initiative is undertaken to simplify, perfect and encode the method of the double contrast barium enema: Altaras from Germany, Miller from USA and Cittadini from Italy are responsible for the perfection of this technique in the last 30 years. The tailored patient preparation, a perfect technique of execution and a precise radiological documentation are essentials steps to obtain a reliable examination. The main limit of double contrast enema is that it considers the pathology only from the mucosal surface. In neoplastic pathology evaluation the main limit is the "T" parameter staging, but more limited are the "N" and "M" parameters evaluation. Today the double contrast technique continues to be a refined, sensitive and specific diagnostic method, moreover, diagnostic results cannot compete with the new CT multislice techniques (CT-enteroclysis and virtual colonoscopy) which can examine both the lumen and the wall of the colon. The double contrast is a cheap and simple examination but in the next future is predictably a progressive substitution of conventional radiology from new multislice techniques, because the cross sectional imaging is more frequently able to detect causes of the symptoms whether resulting both from colonic or non colonic origin.

  13. Double contrast barium enema: Technique, indications, results and limitations of a conventional imaging methodology in the MDCT virtual endoscopy era

    International Nuclear Information System (INIS)

    Rollandi, Gian Andrea; Biscaldi, Ennio; DeCicco, Enzo

    2007-01-01

    The double contrast barium enema of the colon continues to be a diffused conventional radiological technique and allows for the diagnosis of neoplastic and inflammatory pathology. After the '70s, a massive initiative is undertaken to simplify, perfect and encode the method of the double contrast barium enema: Altaras from Germany, Miller from USA and Cittadini from Italy are responsible for the perfection of this technique in the last 30 years. The tailored patient preparation, a perfect technique of execution and a precise radiological documentation are essentials steps to obtain a reliable examination. The main limit of double contrast enema is that it considers the pathology only from the mucosal surface. In neoplastic pathology evaluation the main limit is the 'T' parameter staging, but more limited are the 'N' and 'M' parameters evaluation. Today the double contrast technique continues to be a refined, sensitive and specific diagnostic method, moreover, diagnostic results cannot compete with the new CT multislice techniques (CT-enteroclysis and virtual colonoscopy) which can examine both the lumen and the wall of the colon. The double contrast is a cheap and simple examination but in the next future is predictably a progressive substitution of conventional radiology from new multislice techniques, because the cross sectional imaging is more frequently able to detect causes of the symptoms whether resulting both from colonic or non colonic origin

  14. The early manifestation of Yersinia colitis demonstrated by the double-contrast barium enema

    International Nuclear Information System (INIS)

    Aspestrand, F.

    1986-01-01

    A 19-year old female with a bloody, diarrheal illness of acute onset where Crohn's disease primarly was suspected is presented. The double-contrast barium enema revealed multiple, diffusely scattered aphthous erosions of the colonic mucosa: the rectum was scarcely affected. Biopsies taken by endoscopy demonstrated nonspecific inflammatory changes of the mucous membrane. However, routinely taken stool cultures revealed an infectious colitis due to Yersinia enterocolitica. Our case demonstrates the necessity to consider Yersinia enterocolitis in the radiographic differential diagnosis when the diagnosis of Crohn's disease or ulcerative colitis seems obvious. (orig.) [de

  15. Double contrast barium enema combined with non-invasive imaging in peritoneal mesothelioma

    International Nuclear Information System (INIS)

    Cozzi, G.; Bellomi, M.; Frigerio, L.F.; Ostinelli, C.; Marchiano, A.; Petrillo, R.; Severini, A.; Milan Univ.

    1989-01-01

    Mesotheliomas are rare tumors arising from serosal linings of the major serous cavities. Five patients with peritoneal mesothelioma underwent a double contrast barium enema (DCBE) and ultrasonography (US) (2 patients), computed tomography (CT) (3 patients) and/or magnetic resonance imaging (MRI) (3 patients). The diagnosis was confirmed at laparotomy. The radiologic pattern at DCBE is unspecific and consists of compression and dislocation of bowel loops by extrinsic masses. Mesenteric retraction and segmental stenosis may be present. In one patient DCBE was normal. US, CT and MRI findings are also unspecific but when combined with information obtained from DCBE the site and abdominal extension of the disease are well defined. (orig.)

  16. Is a Double Contrast Barium Enema Necessary in Patients who Undergo a CT Colonography as a Preoperative Work-up?

    International Nuclear Information System (INIS)

    Lee, Ji Won; Lee, Soon Jin; Choi, Dong Il; Kim, Hee Jung; Chun, Ho Kyung; Yun, Seong Hyeon; Jeon, Yong Hwan; Park, Seung Bae; Kim, Min Ju

    2009-01-01

    To determine the efficiency of CT colonography (CTC), as compared with the double contrast barium enema (DCBE) for the preoperative work-up of colorectal neoplasms. A total of 39 patients underwent both a CTC and DCBE before surgery. Three abdominal radiologists and three colorectal surgeons retrospectively reviewed virtual double contrast (VDC) and DCBE images, regarding each examination for localization, conspicuity, extent and morphology of neoplasms. We reviewed the radiological reports of the CTC and DCBE for the polyps. In the case of both VDC and DCBE, 40 cancers were detected in 39 patients. According to abdominal radiologists, VDC showed the same ability to identify DCBE for localization of neoplasms (p 0.05). The performance of the CTC is comparable to the DCBE for the localization of main mass and polyps in patients with colorectal neoplasm. Barium enema don't seem to be necessary for patients who undergo a CTC as preoperative work-up

  17. An oral modified-release nifedipine tablet (Adalat LA) and its appearance on double contrast barium enema

    International Nuclear Information System (INIS)

    Bleehen, Robert E.

    2000-01-01

    Adalat LA 30 mg and 60 mg tablets are widely prescribed oral modified release nifedipine preparations with a porous, non-digestible plastic tablet coating which is required in order to effect the osmotically driven slow release mechanism. These tablets may therefore be seen anywhere along the gastrointestinal tract and are passed apparently whole in the faeces. An example of the appearance within the rectum of Adalat LA 30 (Bayer) on double contrast barium enema is shown and the main features described. A review of the literature is given. Recognition of the appearances during the barium enema examination will prompt those performing the procedure to question the drug history where relevant and will reduce the incidence of false-positive reporting. Bleehen, R.E. (2000)

  18. Experimental studies on the development of Falibaryt HD, a new high density barium meal for double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Dietze, R.

    1985-01-01

    During the development of a new double contrast barium meal barium sulfate preparations with different densities, additives and particle size distributions were tested. Phantoms made of leather, rubber and dissected stomachs of cows and pigs. High density bariumsulfat suspension (200 - 250 % weight/volume) of low viscosity and suitable particle size spectrum containing additives improving the adherence (e.g. natrium citrate) displayed the best quality parameters for optimal imaging of the fine mucosal relief. (author)

  19. A randomized prospective triaI comparing oral sodium phosphate with magnesium citrate in preparing of patients for double contrast barium enema

    International Nuclear Information System (INIS)

    Lee, Eun Joo; Lee, Sung Woo; Lee, Hyeon Kyeong; Yang, Chang Hun; Kim, Soon; Oh, Yoen Hee; Kim, Seung Hyeon

    2004-01-01

    The purpose of this study was to compare two bowel preparation agents, sodium phosphate solution with magnesium citrate solution. A total of 94 subjects that underwent a double-contrast barium enema were included in this study. Bowel preparation before performing the barium study was done by using a sodium phosphate solution in 47 subjects and by using a magnesium citrate solution in the other 47 subjects. We evaluated the presence or absence of side effects when using these bowel preparation agents. Two radiologist who were blinded to the type of bowel preparation evaluated the quality of bowel preparation at the colonic segments (ascending, descending, and sigmoid colon) on the radiographs obtained by double-contrast barium enema, with regard to stool cleansing, water retention, barium coating and bubble formation. The side effects, such as abdominal clamping pain, nausea, hunger pain and chill occurred more frequently in the sodium phosphate group than in the magnesium citrate group (p< 0.001). Stool retention was more frequently found in the magnesium citrate group (p< 0.001). However, no statistical difference was noted on the status of water retention and barium coating between two groups. Gas bubble formation was more commonly seen in the sodium phosphate group (p< 0.001). The sodium phosphate solution appeared to be more effective in cleansing the right colon (p=0.001). Sodium phosphate solution appears to be more effective for colonic cleansing, with a lower incidence of side effects, than when using magnesium citrate solution

  20. Prevention of crackle in double contrast examinations of the colon

    International Nuclear Information System (INIS)

    Carvalho, A. de; Madsen, B.

    1981-01-01

    Crackle of the barium contrast during double contrast examinations of the colon probably results from a drying effect due to resoption of water. The duration of the examination should therefore be kept as short as possible and the patient should be well hydrated. The tendency to crackle can be decreased by increasing the molality of the barium enema by suspending barium contrast in 0.4% saline. (Auth.)

  1. Role of the double-contrast barium enema in rectal stenosis due to suppositories containing paracetamol and acetylsalicylic acid

    International Nuclear Information System (INIS)

    Tannouri, F.; Lalmand, B.; Zalcman, M.; Gansbeke, D. van; Gevenois, P.A.; Struyven, J.; Peny, M.O.; Gossum, A. van

    1998-01-01

    Self-treatment of chronic headache with suppositories containing paracetamol and acetylsalaicylic acid may lead to serious complications. We report the radiological features of five cases of rectal stenosis following the use of such suppositories. The role of the double-contrast barium enema in suggesting the diagnosis of this complication of a chronic and often unrecognized self-treatment is emphasized. (orig.)

  2. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  3. Detection of colonic polyps in the elderly: Optimization of the single-contrast barium enema examination

    International Nuclear Information System (INIS)

    Gelfand, D.W.; Chen, Y.M.; Ott, D.J.; Munitz, H.A.

    1986-01-01

    Single-contrast studies account for 75% of barium enema examinations and are often performed in the elderly. By optimizing all factors, the following results were obtained: for polyps of less than 1 cm, 40 of 57 were detected (sensitivity, 70.2%); for polyps of 1 cm or larger, 33 of 35 were detected (sensitivity, 94%). Overall, 73 of 92 polyps were detected (sensitivity, 79.3%). These sensitivities result from meticulous preparation and the use of compression filming, low-density barium, moderate kilovoltages, high-resolution screens, remote control apparatus, and high-bandpass TV fluoroscopy. The authors conclude that an optimal single-contrast barium enema examination detects colonic polyps with a sensitivity approaching that of the double-contrast study and may be employed in elderly patients who cannot undergo the double-contrast study

  4. Limitations of combined flexible sigmoidoscopy and double contrast barium enema in patients with rectal bleeding

    International Nuclear Information System (INIS)

    Hixson, L.J.; Sampliner, R.E.; Chernin, M.; Amberg, J.; Kogan, F.; Veterans Administration Medical Center, Tucson, AZ

    1989-01-01

    Eighty-seven outpatients with non-massive rectal bleeding or asymptomatic positive fecal occult blood were evaluated with 35 cm flexible sigmoidoscopy, double contrast barium enema (DBCE) and colonoscopy. 82% had hemorrhoids and 35% harbored colorectal neoplasia. The combination of flexible sigmoidoscopy and DCBE missed none of 7 malignant lesions. However, 35% of benign polyps ≥ 1 cm and 60.5% of those < 1 cm were not detected by this combination. The presence of hemorrhoids should not prevent a search for colon neoplasia and colonoscopy is the preferred method. (orig.)

  5. Post double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    In a prospective study, the effect of a low-density contrast medium infusion was evaluated as an adjunct to high-density double-contrast medium sigmoid imaging. Following a double-contrast medium barium enema (DCBE), 52 consecutive patients with sigmoid diverticulosis received an additional 500-700-mL enema with either water or a 1.5%CT barium suspension. Rectosigmoid films were evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and interpretation of polypoid defects. While double-contrast medium views were excellent in 21%, improvement in multiple factors by water or 1.5% barium flush resulted in improved sigmoid images in 65% and 73% of patients, respectively. Polyps may be confirmed and artifactual defects confidently excluded. Sigmoid flush, particularly with low-density barium, is a simple adjunct to DCBE that improves visualization of the diverticular sigmoid

  6. Role of the double-contrast barium enema in rectal stenosis due to suppositories containing paracetamol and acetylsalicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tannouri, F.; Lalmand, B.; Zalcman, M.; Gansbeke, D. van; Gevenois, P.A.; Struyven, J. [Department of Radiology, Hopital Erasme, University of Brussels (Belgium); Peny, M.O. [Department of Pathology, University of Brussels (Belgium); Gossum, A. van [Department of Gastroenterology, University of Brussels (Belgium)

    1998-09-01

    Self-treatment of chronic headache with suppositories containing paracetamol and acetylsalaicylic acid may lead to serious complications. We report the radiological features of five cases of rectal stenosis following the use of such suppositories. The role of the double-contrast barium enema in suggesting the diagnosis of this complication of a chronic and often unrecognized self-treatment is emphasized. (orig.) With 6 figs., 20 refs.

  7. Post-double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    The sigmoid colon is the most difficult colonic segment to examine radiographically, especially when it is involved by diverticular disease. In a prospective study, infusion of a low-density contrast agent was evaluated as an adjuvant technique to high-density double-contrast sigmoid imaging. After a double-contrast barium enema, 52 consecutive patients with sigmoid diverticulosis received an additional 500-ml enema either with water or with a 1.5% CT barium suspension. Rectosigmoid films were compared and evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and display of polypoid defects. Sigmoid flush, particularly with the 1.5% CT barium suspension, is a simple adjunct to the double-contrast examination that improves visualization of the diverticular sigmoid and increases diagnostic specificity

  8. Colonic diverticulosis: evaluation with double contrast barium enema

    International Nuclear Information System (INIS)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja

    1997-01-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west

  9. Colonic diverticulosis: evaluation with double contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja [Korea Veterans Hospital, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west.

  10. Aspiration of Barium Contrast

    OpenAIRE

    Fuentes Santos, Cristina; Steen, Bárbara

    2014-01-01

    The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical fil...

  11. Advanced method of double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Vlasov, P.V.; Yakimenko, V.F.

    1981-01-01

    An advanced method of double contrast examination of the stomach with the use of high concentrated barium suspension is described. It is shown that concentration of barium suspension must be not less than 200 mass/volume per cent to obtain the sharp image of the mucosal microrelief 6 standard position are recommended for the double contrast examination of all stomach walls. 200 patients with different digestive system diseases are examined with the help of developed methods. The sharp image of the mucosal microrelief is obtained in 70% cases [ru

  12. Degree of mucosal coating on double contrast barium enema : comparison of distilled water and normal saline as a suspension

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Lee, Dong Ho; Ko, Young Tae; Lim, Joo Won; Han, Tae Il; Kim, Hyoung Jung

    1997-01-01

    To evaluate the degree of mucosal coating on double contrast barium enema (DCBE), using barium suspension made with distilled water or normal saline Between June 1 and July 30, 1996, fifty-four patients prospectively underwent DCBE using 83% w/v(weight-to-volume) of barium suspension (room temperature, 24 deg C), which was made with 1,200mL of distilled water (Group 1;29cases) and normal saline (Group 2;25cases) per 1Kg of Solotop (Taejoon Pharmacy, Seoul, Korea). Bowel preparation and examination methods were the same in both groups, and four projections(erect view, supine view, both decubitus views) were taken. The mucosal coating was graded as excellent, good, ordinary, or poor by three radiologists working independently, and scored from 3 to 0. Significance was analyzed by t-test. Mean grading scores were 2.33±0.70 in group 1 and 1.56±0.99 in group 2 (P<0.003). When barium suspension made with distilled water was used, the degree of mucosal coating on DCBE was better than when the suspension was made with normal saline

  13. Lower GI Series (Barium Enema)

    Science.gov (United States)

    ... uses x-rays and a chalky liquid called barium to view your large intestine . The barium will make your large intestine more visible on ... single-contrast lower GI series, which uses only barium a double-contrast or air-contrast lower GI ...

  14. Double contrast barium enema sensitivity: A comparison of studies by radiographers and radiologists

    International Nuclear Information System (INIS)

    Culpan, D.G.; Mitchell, A.J.; Hughes, S.; Nutman, M.; Chapman, A.H.

    2002-01-01

    PURPOSE: A retrospective study of histologically proven cases of colorectal cancer (CRC) was performed to assess whether the sensitivity of the radiographer-performed double contrast barium enema (DCBE) differed from that of the radiologist-performed study. MATERIALS AND METHODS: Histologically proven cases of CRC were reviewed over a 3-year period to ascertain whether: the diagnosis had been made by DCBE in the 3 years before histological diagnosis; the lesion had been correctly diagnosed; the examination had been performed by a radiologist or radiographer. RESULTS: In the 3-year period there were 478 cases with histologically proven CRC. Of these, 239 (50%) had undergone DCBE as the initial radiological investigation of the colon. Sixty-four examinations had been performed by radiographers. A correct diagnosis was made in 58 cases (90.6%), the report was equivocal in one case (1.6%), there were four false-negatives (6.25%), and one case was abandoned (1.6%). One hundred and seventy-five examinations were performed by radiologists. A correct diagnosis was made in 157 cases (89.7%), the report was equivocal in one case (0.6%), there were 16 false-negatives (9.1%), and one case was abandoned (0.6%). CONCLUSION: A sensitivity of 90.6% for radiographer-performed studies compared favourably with 89.7% for radiologist-performed studies and supports the practice of radiographers undertaking barium enemas. Culpan, D.G. et al. (2002)

  15. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis.

    Science.gov (United States)

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-09-07

    The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups' results. Findings from RWC-TVS or DCBE were compared with histological results. The severity of experienced pain severity through RWC-TVS or DCBE was assessed by an analogue scale of 10 cm. In total, 110 in 198 women were confirmed to have endometriosis nodules in the bowel by laparoscopy as well as histopathology. For bowel endometriosis diagnosis, DCBE and RWC-TVS demonstrated sensitivities of 96.4% and 88.2%, specificities of 100% and 97.3%, positive prediction values of 100% and 98.0%, negative prediction values of 98.0% and 88.0%, accuracies of 98.0% and 92.4%, respectively. DCBE was related to more tolerance than RWC-TVS. RWC-TVS and DCBE demonstrated similar accuracies in the bowel endometriosis diagnosis; however, patients showed more tolerance for RWC-TVS than those with DCBE. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Dose optimisation of double-contrast barium enema examinations.

    Science.gov (United States)

    Berner, K; Båth, M; Jonasson, P; Cappelen-Smith, J; Fogelstam, P; Söderberg, J

    2010-01-01

    The purpose of the present work was to optimise the filtration and dose setting for double-contrast barium enema examinations using a Philips MultiDiagnost Eleva FD system. A phantom study was performed prior to a patient study. A CDRAD phantom was used in a study where copper and aluminium filtration, different detector doses and tube potentials were examined. The image quality was evaluated using the software CDRAD Analyser and the phantom dose was determined using the Monte Carlo-based software PCXMC. The original setting [100 % detector dose (660 nGy air kerma) and a total filtration of 3.5 mm Al, at 81 kVp] and two other settings identified by the phantom study (100 % detector dose and additional filtration of 1 mm Al and 0.2 mm Cu as well as 80 % detector dose and added filtration of 1 mm Al and 0.2 mm Cu) were included in the patient study. The patient study included 60 patients and up to 8 images from each patient. Six radiologists performed a visual grading characteristics study to evaluate the image quality. A four-step scale was used to judge the fulfillment of three image quality criteria. No overall statistical significant difference in image quality was found between the three settings (P > 0.05). The decrease in the effective dose for the settings in the patient study was 15 % when filtration was added and 34 % when both filtrations was added and detector dose was reduced. The study indicates that additional filtration of 1 mm Al and 0.2 mm Cu and a decrease in detector dose by 20 % from the original setting can be used in colon examinations with Philips MultiDiagnost Eleva FD to reduce the patient dose by 30 % without significantly affecting the image quality. For 20 exposures, this corresponds to a decrease in the effective dose from 1.6 to 1.1 mSv.

  17. Contrast characteristics of barium preparations and the timing of exposure

    OpenAIRE

    渋谷, 光一; 中桐, 義忠; 東, 義晴; 杉田, 勝彦; 小橋, 高郎; 大倉, 保彦; 丹谷, 延義; 三上, 泰隆; 平木, 祥夫

    1995-01-01

    We studied the relationship between the contrast characteristics of barium suspension and timing of exposure. We poured several kinds of barium preparations on the phantom manufactured by ourselves, and took X-ray pictures continuously by a DSA system. We analyzed each of the characteris-tics of the contrast. The time which was reguired for the contrast to reach the peak (Contrast Peak Time ; CPT) was unrelated with the kind of barium preparations used. It depended on the viscosity of the con...

  18. [Practical usage of a quality management system according to ISO 9001 : 2000 focusing on the double contrast (barium) enema].

    Science.gov (United States)

    Heinzle, G; Hergan, K; Fleisch, M; Hubmann, M; Oser, W

    2001-12-01

    We describe the implementation of quality improvement measures in a quality management system. With questionnaires for radiologists and patients, we investigated the relations between patient preparation and diagnostic quality serving the main purpose, to improve diagnostic quality with the help of more detailed patient information (e.g., changing preparation sheets and handling out "peri-med" information sheets to the patients). Furthermore, a comparative data ascertainment at other institutes was integrated. For the group of outpatients, increasing process quality (patient information) and outcome (diagnostic quality) could be achieved. Taking aspects of quality costs into consideration, a decrease in costs due to failures was achieved. More detailed patient information has positive effects on diagnostic quality of the double contrast (barium) enema.

  19. In vitro tests of barium sulphate suspensions for double contrast examinations of the stomach

    International Nuclear Information System (INIS)

    Treugut, H.; Huebener, K.H.

    1980-01-01

    Four barium sulphate suspensions were investigated with respect to their adhesion and contrast following standard means of spreading the contrast over a model stomach, which corresponds in its detailed structure with the surface of the gastric mucosa. By this means various factors, which make a true comparison in vivo impossible, could be eliminated and a comparison of the suspensions became possible. Using similar mechanical and chemical situations, the radiographs of the artificial mucosa showed very different results from the use of the different preparations. These corresponded well with the findings in vivo. (orig.) [de

  20. Evaluation of colonic involvement in endometriosis: double-contrast barium enema vs. magnetic resonance imaging.

    Science.gov (United States)

    Faccioli, N; Foti, G; Manfredi, R; Mainardi, P; Spoto, E; Ruffo, G; Minelli, L; Mucelli, R Pozzi

    2010-08-01

    The purpose of the study was to compare the accuracy of double-contrast barium enema (DCBE) and magnetic resonance imaging (MRI) in the diagnosis of intestinal endometriosis using the histological examination on resected specimen as comparative standard. Eighty-three consecutive patients with suspected intestinal endometriosis, resected between 2005 and 2007, were prospectively evaluated. All of the women underwent preoperative DCBE and MRI on the same day. We evaluated number, site (rectum, sigmoid, cecum), and size of the lesions. The imaging findings were correlated with those resulting at pathology. Among the 65 women who underwent surgery, 50/65 (76.9%) were found to have bowel endometriosis, with 9/50 (18%) patients presenting two lesions; DCBE allowed to detect 50/59 (84.7%) lesions. MRI allowed to detect 42/59 (71.1%) lesions. DCBE showed sensibility, specificity, PPV, NPV, and accuracy of respectively 84.7, 93.7, 98.0, 62.5, and 86.6%, MRI of 71.1, 83.3, 93.3, 46.8, and 74.6%. DCBE is more accurate than unenhanced MRI in the diagnosis of bowel endometriosis, and should be preferred in the preoperative management of this disease, since it usually enables a proper surgical planning.

  1. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  2. Double-contrast barium enteroclysis as a patency tool for nonsteroidal anti-inflammatory drug-induced enteropathy.

    Science.gov (United States)

    Matsumoto, Takayuki; Esaki, Motohiro; Kurahara, Koichi; Hirai, Fumihito; Fuchigami, Tadahiko; Matsui, Toshiyuki; Iida, Mitsuo

    2011-11-01

    Evaluating small bowel patency is recommended for capsule endoscopy in patients suspected of nonsteroidal anti-inflammatory drug-induced (NSAID) enteropathy. The aim of this investigation was to examine whether radiography is a candidate of patency tool in NSAID enteropathy. We reviewed double-contrast barium enteroclysis in 21 patients with NSAID enteropathy diagnosed either by capsule endoscopy or balloon-assisted endoscopy. The endoscopic findings were classified into circular ulcers, linear ulcers and small mucosal defects. The radiographic signs of the corresponding endoscopic findings were retrieved and the depiction rate was calculated. Of the 21 patients, endoscopy detected circular ulcers, linear ulcers, and small ulcers in 12, 3 and 12 patients, respectively. Small bowel radiography depicted circular narrowing as pseudo-folds in 10 patients (83%) and linear ulcers as eccentric rigidity in 2 patients (67%). However, radiography was able to depict small mucosal defects in only 3 patients (17%). Two of 5 patients with pseudo-folds experienced retention of the capsule. "Pseudo-folds" is a sign corresponding to circular ulcer in NSAID enteropathy, which may be predictive of capsule retention.

  3. A modified per os double contrast examination of the colon in the elderly

    International Nuclear Information System (INIS)

    Papadaki, P.J.; Vassiliou, P.M.; Zavras, G.M.; Kounis, N.G.; Hadjioannou, N.; Fezoulidis, I.B.; Manolakis, P.; Kelekis, D.

    1993-01-01

    A modified per os double contrast examination of the colon was used in 62 elderly patients in whom conventional barium enema had been unsuccessful. We created endogenous gas generation instead of air insufflation by per os administration of a special mixture containing barium sulftate, lactulose and gastrographin. Good quality double contrast images of the colon were obtained after 12 hours in 59 of the 62 patients. The sensitivity of the method was 100% in 6 patients suffering from carcinoma and in 15 patients suffering from diverticular disease. However, the method failed to demonstrate small solitary polyps in 5 patients and it was also negative in another 27 patients. 7 of these had negative endoscopy and in the remaining a definite diagnosis was not established by any other method. It seems that this method may become an alternative for investigation of suspected colonic pathology in the elderly patients with difficulty in retaining the barium enema. (orig.) [de

  4. A modified per os double contrast examination of the colon in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Papadaki, P J [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Vassiliou, P M [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Zavras, G M [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Kounis, N G [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Hadjioannou, N [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Fezoulidis, I B [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Manolakis, P [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patra

    1993-04-01

    A modified per os double contrast examination of the colon was used in 62 elderly patients in whom conventional barium enema had been unsuccessful. We created endogenous gas generation instead of air insufflation by per os administration of a special mixture containing barium sulftate, lactulose and gastrographin. Good quality double contrast images of the colon were obtained after 12 hours in 59 of the 62 patients. The sensitivity of the method was 100% in 6 patients suffering from carcinoma and in 15 patients suffering from diverticular disease. However, the method failed to demonstrate small solitary polyps in 5 patients and it was also negative in another 27 patients. 7 of these had negative endoscopy and in the remaining a definite diagnosis was not established by any other method. It seems that this method may become an alternative for investigation of suspected colonic pathology in the elderly patients with difficulty in retaining the barium enema. (orig.)

  5. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  6. Double-contrast examination of the gastric antrum without Duodenal superposition

    International Nuclear Information System (INIS)

    Treugut, H.; Isper, J.

    1980-01-01

    By using a modified technique of double-contrast examination of the stomach it was possible in 75% to perform a study without superposition of the duodenum and jejunum on the distal stomach compared to 36% with the usual method. In this technique a small amount (50 ml) of Barium-suspension is given to the patient in left decubitus position by a straw or gastric tube after antiperistaltic medication. There was no difference in the quality of mucosa-coating compared to the technique using higher volumes of Barium. (orig.) [de

  7. Selective use of the biphasic-contrast barium enema study for evaluation of colonic lesions: Results of a prospective study

    International Nuclear Information System (INIS)

    De Lange, E.E.; Shaffer, H.A. Jr.; Riddervold, H.O.

    1987-01-01

    The authors performed a prospective study to determine the value of selective use of the biphasic contrast technique for a variety of indications. In a series of 571 double-contrast barium enema examinations, the examination was immediately followed by a single-contrast study in 85 cases. The biphasic procedure was performed to reexamine a colonic segment that was poorly evaluated initially because of diverticulosis (eta = 35), incomplete filling (eta = 28), or poor mucosal coating (eta = 26); or to verify or exclude a possible lesion identified during the double-contrast examination (eta = 22). The single-contrast study confirmed five polyps and excluded lesions in 17 cases with suspected polyps (eta = 5), strictures (eta = 4), and spasm (eta = 8). Six polyps not visualized on the double-contrast examination were detected with the single-contrast procedure

  8. Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    It has been proposed that the high density of ordinary barium suspension may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm/sup 3/). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

  9. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

    Science.gov (United States)

    Anderson, N G; Butler, A P; Scott, N J A; Cook, N J; Butzer, J S; Schleich, N; Firsching, M; Grasset, R; de Ruiter, N; Campbell, M; Butler, P H

    2010-09-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications.

  10. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G. [University of Otago, Department of Radiology, Christchurch (New Zealand); Butler, A.P. [University of Otago, Department of Radiology, Christchurch (New Zealand); University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Scott, N.J.A. [University of Otago, Department of Medicine, Christchurch (New Zealand); Cook, N.J. [Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Butzer, J.S. [Karlsruhe Institute of Technology, Physics Department, Karlsruhe (Germany); Schleich, N. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Firsching, M. [Friedrich Alexander University, Physics Department, Erlangen (Germany); Grasset, R.; Ruiter, N. de [University of Canterbury, Hitlab NZ, Christchurch (New Zealand); Campbell, M. [European Organisation for Nuclear Research, Physics Section, Geneva (Switzerland); Butler, P.H. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand)

    2010-09-15

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 {mu}A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 {mu}m isotropic voxels. Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. (orig.)

  11. [Value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer].

    Science.gov (United States)

    Wang, Chang-jian; Zhao, Guang-fa; Li, Qing-guo; Chen, Jing-gui; Zhu, Kai; Shi, Ying-qiang; Fu, Hong

    2010-04-01

    To investigate the value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer. Clinical data of 229 gastric cancer patients were analyzed retrospectively. Lesions were divided into three parts: the cardiac, the body, and the antrum. The diagnostic accuracy of localization and the extent of tumor between gastroscopy alone and gastroscopy plus barium contrast were compared with the results of surgical findings. The diagnostic accuracy of localization and the extent of tumor for gastroscopy in the cardiac, the body and the antrum cancers were 100% and 78.4%, 94.6% and 86.5%, 98.1% and 84.6%, respectively, while for gastroscopy plus barium contrast were 100% and 84.8%, 100% and 91.9%, 99.0% and 90.4%, respectively. The diagnostic accuracy of both the localization and the extent of tumor were not significantly different between gastroscopy alone and gastroscopy plus barium contrast (P>0.05). Diagnostic accuracy of the length of esophagus infiltrated by cardiac cancer in gastroscopy was 60.6%, while in gastroscopy plus barium contrast was 90.9%, which was significantly different (Pbarium contrast was more accurate in predicting the possibility of thoracotomy in cardiac cancer infiltrating the lower esophagus. It is necessary to perform preoperative barium contrast examination in cardiac cancer patients, so as to identify whether the lower esophagus is infiltrated and to measure the length of lesion, which can provide evidences for making a decision of thoracotomy. For gastric body and antrum cancer, there is no indication for barium contrast examination if gastroscopy findings are satisfied.

  12. CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden.

    Science.gov (United States)

    Neri, Emanuele; Faggioni, Lorenzo; Cerri, Francesca; Turini, Francesca; Angeli, Simone; Cini, Lorenzo; Perrone, Franco; Paolicchi, Fabio; Bartolozzi, Carlo

    2010-10-01

    Our aim is to compare the radiation dose associated with a low-dose CT colonography (CTC) protocol for colorectal cancer screening with that delivered by double-contrast barium enema (DCBE). CTC of twenty asymptomatic individuals (M:F = 10:10) participating to a colorectal cancer screening program and DCBE of fifteen patients (M:F = 6:9) were evaluated. For CTC, absorbed dose was determined by calculating the dose-length product for each CTC examination from measurements on a CT dose phantom equipped with a CT ion chamber. For DCBE, the free-in-air Kerma at the patient's X-ray entry surface and the Kerma-area product during fluoroscopy and fluorography were measured with a Barracuda system, with fluoroscopy times being recorded blinded to the performing operator. Effective dose at CTC was 2.17 ± 0.12 mSv, with good and excellent image quality in 14/20 (70%) and 6/20 cases (30%), respectively. With DCBE, effective patient dose was 4.12 ± 0.17 mSv, 1.9 times greater than CTC (P < 0.0001). Our results show that effective dose from screening CTC is substantially lower than that from DCBE, suggesting that CTC is the radiological imaging technique of the large bowel with the lowest risk of stochastic radiation effects.

  13. Prospective comparison of air-contrast barium enema and colonoscopy in patients with fecal occult blood: a pilot study.

    Science.gov (United States)

    Rockey, Don C; Koch, Johannes; Yee, Judy; McQuaid, Kenneth R; Halvorsen, Robert A

    2004-12-01

    The utility of air-contrast barium enema and colonoscopy for evaluation of the colon has been debated. Air-contrast barium enema is less expensive and invasive than colonoscopy, but it also is less sensitive and specific. Further, although air-contrast barium enema may be less painful than colonoscopy, it often is poorly tolerated by patients. Thus, this study compared the sensitivity and the specificity of air-contrast barium enema and colonoscopy for detection of colonic lesions in patients with fecal occult blood. Over a 30-month period, patients with fecal occult blood were recruited. Patients underwent standard air-contrast barium enema, followed by colonoscopy 7 to 14 days later. Colonoscopists were blinded to the results of air-contrast barium enema until the colonoscopy was completed, after which the results were disclosed. If the findings were discrepant, colonoscopy was repeated. A total of 100 patients were evaluated. Nine air-contrast barium enemas were reported to be inadequate, and the cecum was not intubated at colonoscopy in two patients. In the remaining patients, 5 cancers were identified (1 each cecum, transverse colon, descending colon, sigmoid colon, and rectum) by both studies. Sixty-six polypoid lesions were identified in 30 patients. Diverticula were identified in 42 patients by air-contrast barium enema and in 18 patients by colonoscopy. Air-contrast barium enema detected 3 of 36 polypoid lesions 5 mm or less in diameter, 5 of 15 adenomas 6 to 9 mm in size, and 4 of 15 adenomas 10 mm or greater in diameter (sensitivity 8%, 33%, and 27%, respectively). After excluding patients with diverticula, air-contrast barium enema detected 3 of 7 adenomas 10 mm or greater in size. Overall, 12 polypoid lesions or filling defects were identified by air-contrast barium enema that could not be verified by colonoscopy. The specificity of air-contrast barium enema for lesions 1.0 cm or greater in size was 100%; for those 6 mm or greater, it was 97%. Air-contrast

  14. [Comparison of iodinated and barium-containing contrast media of different viscosity in the detection of pharyngeal perforation].

    Science.gov (United States)

    Keberle, M; Wittenberg, G; Trusen, A; Baumgartner, W; Hahn, D

    2001-08-01

    In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous than the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose.

  15. Water-soluble contrast media compared with barium in enteric follow-through

    International Nuclear Information System (INIS)

    Laerum, F.; Stordahl, A.; Aase, S.

    1988-01-01

    The local effects and radiographic efficacy of 4 water-soluble contrast media, barium and saline were evaluated in 86 anaesthetized rats with the distal ileum ligated. The rats were observed for 8 hours after instillation of 3 ml of the test substance via orogastric tube. Radiographs were taken after 1, 4 and 8 hours of observation. After 8 hours the intestines were weighed and biopsied for light microscopy, and blood and urine were sampled for testing. Sodium diatrizoate caused increased fluid influx to the bowel lumen and, like barium, provided poorer radiographic images as compared with iohexol, ioxaglate or iodixanol. Barium showed slower progression through the small bowel than the other agents, while sodium diatrizoate was the most rapidly progressing contrast medium and caused the greatest distension. Correlation to osmolality was obvious. No significant morphologic effects on the small bowel mucosa were seen in any of the groups. Low-osmolar, water-soluble contrast media may have prospects for clinical use in patients with suspected small bowel obstruction. (orig.)

  16. Outcome of barium enema in patients with colorectal symptoms ...

    African Journals Online (AJOL)

    Background: For many years, double contrast barium enema has been an effective way to evaluate the large bowel. With the development of the colonoscope, the role of barium enema has been questioned. However it is still useful in investigating patients with colorectal symptoms especially in the developing world where ...

  17. Low residual diet and hydration improving double contrast examination of the colon

    International Nuclear Information System (INIS)

    Virkki, R.; Maekelae, P.

    1983-01-01

    Light food diet and low residual diet with hydration, both combined with Proctosal and Bisacodyl cleansing, were compared in 268 patients in the preparation of the colon for double contrast examination. Low residual diet with hydration resulted in significantly less residual fecal material, no flocculation of the barium coating and significantly denser mucosal coating. The examination had to be repeated more often (8.6%) after light food diet than after low residual diet with hydration (1.7%), but there was no statistically significant difference in the diagnostic accuracy. The hydration is important in avoiding patient discomforts and flocculation of the barium coating. Despite the use of laxatives, a strict diet restriction is needed to obtain consistently clean colon. (orig.)

  18. Radiological diagnostics of the early gastric carcinoma by means of the double-contrast technique

    Energy Technology Data Exchange (ETDEWEB)

    Faust, H

    1981-05-01

    Radiological efforts to detect early gastric cancer have been intensified by three facts: 1) the prognostic importance, 2) the world-wide accepted classification of early cancer, 3) by comparison with the findings of gastrocamera and endoscopy. Main factors in double-contrast barium meal are: distention of the stomach by at least 200 cc gas, gastric atony (Glucagon or anticholinergica), visualization of the total gastric mucosa by high density, low viscosity barium after washing out the mucus from the mucosal relief. Radiological symptoms of early cancer are demonstrated, the urgency of en-face documentation of gastric ulcers is stressed.

  19. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    CERN Document Server

    Anderson, NG; Firsching, M; de Ruiter, N; Schleich, N; Butzer, J S; Cook, N J; Grasset, R; Campbell, M; Scott, N J A; Anderson, N G

    2010-01-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 A mu A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct f...

  20. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Burling, D.; Bassett, P.; Bartram, C.I.

    2005-01-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients

  1. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)]. E-mail: csytaylor@yahoo.co.uk; Halligan, S. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Burling, D. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bassett, P. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bartram, C.I. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)

    2005-02-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

  2. Assessment of patient exposure for barium enema examinations

    International Nuclear Information System (INIS)

    Bednarek, D.R.; Rudin, S.; Wong, R.

    1983-01-01

    Methods are described for the assessment of patient exposure during clinical fluoroscopic procedures. Values of the roentgen-area-product (RAP) and their distribution throughout the examination are presented for both single-contrast and double-contrast barium enema studies. The double-contrast procedure was measured to give 50% more radiation to the patient than the single-contrast procedure when the same size optical aperture is used between the intensifier and TV pick-up tube. However, it was possible to decrease the fluoroscopic RAP value by over a factor of two for the double-contrast procedure without an adverse clinical effect by increasing the area of the aperture diaphragm

  3. Preliminary evaluation of helical CT colonography in detection of colonic diseases compared with double contrast barium enema

    International Nuclear Information System (INIS)

    Zhai Xiaoli; Zhang Lei; Zhai Renyou; Li Jie; Wang Yajie; Ding Yi

    2000-01-01

    Objective: To evaluate helical CT colonography in regard to technology principles, limitations, and clinical applications. Methods: Fifty-six patients underwent volume scanning using helical CT. The diseases included adenocarcinoma 39, adenomatous polyp 3, multiple diverticular 7, mucocele of appendix 1, and normal colon 6. All cases had been compared with double contrast barium enema (DCBE), proved by histology except the 6 normal colon and the 7 multiple diverticular. All CTC images were reconstructed using shaded surface display (SSD) on workstation. Then, perspective images such as the ones from DCBE were generated via ray sum. The images could clearly demonstrate the extent and detail of the disorder by using 'CUT' software, 'revolve' function, and zoom. Results: CTC correctly demonstrated 3-5 mm diverticulum, 3 mm ulcer, and 6 mm polyps. Not only show colon straitness clearly, CTC is also very sensitive to demonstrate the stenotic end of masses. In these cases, discovery rate of CTC is 100.0%, the rate of DCBE is 88.6%; CTC is more sensitive than DCBE in cases of tumor nodules. Ray sum can show the boundary of colonic mass extending to both proximal and distal ends, its discovery rate is 62.6%. Accuracy of localization for CTC is 100.0%. Conclusion: CTC is a novel technique for detecting colonic diseases. It is a safe, accurate, and non-invasive means for detection of lesions and is an efficient complement for DCBE. Further development in CTC technique is expected in the future

  4. MR Colonography with fecal tagging: Barium vs. barium ferumoxsil

    DEFF Research Database (Denmark)

    Achiam, M.P.; Chabanova, E.; Logager, V.B.

    2008-01-01

    and Methods. Twenty patients referred to CC underwent dark lumen MRC prior to the colonoscopy. Two groups of patients received two different oral contrast agents (barium sulfate and barium sulfate/ferumoxsil) as a laxative-free fecal tagging prior to the MRC. After MRC, the contrast agent was rated...... qualitatively (with the standard method using contrast-to-wall ratio) and subjectively (using a visual analog scale [VAS]) by three different blinded observers. Results. Evaluated both qualitatively and subjectively, the tagging efficiency of barium sulfate/ferumoxsil was significantly better (P ... barium sulfate alone. The VAS method for evaluating the tagging efficiency of contrast agents showed a high correlation (observer 11, r = 0.91) to the standard method using contrast-to-wall ratio and also a high interclass correlation (observer 11 and III = 0.89/0.85). MRC found I of 22 (5%) polyps

  5. Follow-up barium study after a negative water-soluble contrast examination for suspected esophageal leak: is it necessary?

    Science.gov (United States)

    Sanchez, Thomas R; Holz, Grant S; Corwin, Michael T; Wood, Robert J; Wootton-Gorges, Sandra L

    2015-10-01

    The purpose of this study was to determine the value of follow-up barium esophogram in diagnosing esophageal injury or leak if the initial water-soluble contrast examination of the esophagus is normal. An institutional review board (IRB)-approved retrospective review of all pediatric patients less than 18 years old referred to the radiology department for evaluation of esophageal injury or leak was performed for a 9-year period from 2005 to 2014. The majority of patients had unexplained pneumomediastinum, chest trauma (gunshot or puncture wound), or foreign body ingestion as the reason for the referral. Forty-nine patients (age range 10 days to 17 years) underwent an initial water-soluble esophogram immediately followed by a barium esophogram. Forty-six studies were negative on both water-soluble contrast and barium studies. Two studies were both positive on the initial water-soluble contrast and subsequent barium studies. A single study showed the esophageal leak only in the water-soluble study, with the follow-up barium exam being normal. The result of this study indicates that a single-contrast water-soluble esophogram alone is sensitive in the diagnosis of esophageal injury or leak. It has a 100 % sensitivity and negative predictive value. A follow-up barium esophogram only increases the study time and radiation dose to the patient.

  6. MDCT appearance of the appendix: how does the low-density barium sulfate oral contrast agent affect it?

    Science.gov (United States)

    Yaghmai, Vahid; Aghaei-Lasboo, Anahita; Brandwein, Warren M; Tochetto, Sandra; Mafi, John N; Miller, Frank H; Nikolaidis, Paul

    2011-01-01

    We compared the effect of low-density barium sulfate neutral oral contrast agent on the diameter of normal appendix and its luminal content versus that of water on multidetector-row CT. CT scans of 24 patients who had been imaged on two separate occasions for the evaluation of pancreatic pathology, once with water and subsequently with low-density barium sulfate as the neutral oral contrast agent were evaluated (total of 48 scans). Studies were randomized and reviewed in consensus on a workstation in the stack mode by two radiologists blinded to the type of oral contrast. The appendix was measured at baseline and 10 days later to obtain an average diameter. Results of the water and low-density barium sulfate groups were compared using paired t test. Contents of the appendiceal lumen were also noted (gas, fluid, mixed, and collapsed appendix). The average diameter of the appendix for scans obtained with water and low-density barium sulfate was 4.09 ± 0.87 mm (median, 4.22 mm; range, 2.50-5.65 mm) and 4.13 ± 0.93 mm (median, 4 mm, range, 2.2-5.65 mm), respectively. This difference was not statistically significant (P = 0.69). There was no statistically significant difference in the appendiceal content when water or low-density barium sulfate were used as oral contrast (χ (2) = 4.25, P = 0.89). Low-density barium sulfate does not affect appendiceal content or diameter and, therefore, should not adversely affect evaluation of the appendix on multidetector row CT.

  7. Sensitivity of single contrast barium enema with regard to colorectal disease as diagnosed by colonoscopy

    International Nuclear Information System (INIS)

    Kaude, J.V.; Harty, R.F.

    1982-01-01

    The results of single contrast barium enema were retrospectively correlated with colonoscopically diagnosed colorectal disease in 54 patients (75 lesions). Altogether 66 lesions (88%) were correctly diagnosed. The sensitivity of barium enema for polyps was 81% (26/32). There were three perceptive errors and three polyps 5 mm or less in size were not demonstrated by barium enema. Twenty-nine cases of inflammatory disorders were all correctly diagnosed. One of 12 malignancies was missed by perceptive error. In two cases with vascular malformations the barium enema was normal. 4/9 (44%) of missed lesions were perceptive errors and could have been probably avoided by a second independent reading of films. (orig.)

  8. The impact of high-density barium use in double contrast radiographic methods for gastric cancer screening in Niigata, Japan.

    Science.gov (United States)

    Wakai, Shizuko; Tanabe, Naohito; Suzuki, Hiroshi

    2005-04-01

    Use of high-density barium (= or > 180 w/v%) has been widely spread in community-based mass screening for gastric cancer in Japan. However, the impact on outcomes of the screening has not been fully evaluated. Then, we investigated the advantage of high-density barium use by comparing the outcomes between a period with high-density barium and that with low-density barium (barium decreases the positive finding rate in initial mass screening x-ray examinations by 12% (odds ratio, 0.88; 95% confidence interval, 0.86 - 0.90) and increase the gastric cancer detection rate by diagnostic examination by 15% (odds ratio, 1.15; 95% confidence interval, 1.01-1.31). We conclude that introduction of high-density barium has improved the efficiency of mass screening for gastric cancer by decreasing unnecessary diagnostic examinations and reducing the total personal and public health costs. Thus, nationwide use of high-density barium is recommended for mass gastric cancer screening in Japan.

  9. Barium isotope fractionation during experimental formation of the double carbonate BaMn[CO3](2) at ambient temperature.

    Science.gov (United States)

    Böttcher, Michael E; Geprägs, Patrizia; Neubert, Nadja; von Allmen, Katja; Pretet, Chloé; Samankassou, Elias; Nägler, Thomas F

    2012-09-01

    In this study, we present the first experimental results for stable barium (Ba) isotope ((137)Ba/(134)Ba) fractionation during low-temperature formation of the anhydrous double carbonate BaMn[CO(3)](2). This investigation is part of an ongoing work on Ba fractionation in the natural barium cycle. Precipitation at a temperature of 21±1°C leads to an enrichment of the lighter Ba isotope described by an enrichment factor of-0.11±0.06‰ in the double carbonate than in an aqueous barium-manganese(II) chloride/sodium bicarbonate solution, which is within the range of previous reports for synthetic pure BaCO (3) (witherite) formation.

  10. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  11. Diagnostic role of barium enema in carcinoma rectum

    International Nuclear Information System (INIS)

    Asghar, M.

    2003-01-01

    Objective: The main aim of this barium enema study was to evaluate its role in patients suspected to have rectal pathologies with complaints of change in bowel habit, anorexia/weight loss, bleeding per rectum and acute/sub-acute colonic obstruction. Results: barium enema study as screening test for colo-rectal carcinoma was undertaken. Contrast outlined the colonic growth in 35 cases, out of which the cases of carcinoma colon were 24 including 13 patients suffering from carcinoma rectum. The percentage of carcinoma colon to total colonic growth was 68% while, carcinoma rectum to total carcinoma colon was 54%. Conclusion: On the basis of these investigations, it is concluded that patient's compliance is important factor in the early detection of colonic neoplasia. Though results of colonoscopy are more reliable but in practice, barium enema (double contrast) is performed initially to outline the lesion and then colonoscopy for biopsy purpose. (author)

  12. Results of a cooperative study for the evaluation of the barium meal Falibaryt HD

    International Nuclear Information System (INIS)

    Reisinger, W.; Liess, G.; Beckmann, D.; Block, H.G.; Dietze, R.; Grosche, N.; Hall, E.; Lasch, G.; Knoth, H.J.; Kroeger, W.

    1986-01-01

    The diagnostic capabilities of radiologic investigations of the stomach in double contrast can be significantly improved with high-density low-viscosity barium meals. In the GDR the barium meal Falibaryt HD with a barium sulfate content of 215 g per 100 ml suspension has been developed. In nearly 1,000 radiologic investigations of the stomach (81% in relaxation with spasmolytics, 66% without hypotony) all fine structures were well imaged and the preparation therefore is comparable with the best barium meals presently on the market. (author)

  13. Comparison of three contrast radiographic techniques in the dog large intestine

    International Nuclear Information System (INIS)

    Vargas, L.; Thibaut, J.; Olhaberry, E.; Born, R.; Deppe, R.

    1994-01-01

    In order to compare three radiographic techniques -pneumocolon, barium enema and double contrast- in the large intestine of the dog, three radiographic series in ventrodorsal and right lateral projections were taken. Six healthy adult dogs of both sexes with an approximate weight between 5 to 10 kg were used. Three enemas were administered 24, 12 and 2 hrs. before the series of radiographs were taken. Then dogs were anaesthetized with sodium tiopental (20 mg/kg iv) and the contrast media were introduced. Pneumocolon was carried out in the first series introducing air (20 cc/kg) in the large intestine through a Foley rectal catheter. Radiographs were taken in both projections, after 5 and 15min. respectively. Barium enema was performed in the second series introducing barium sulfate (18%) in the large intestine through a Foley rectal catheter (25 cc/kg); 5 and 15 min. later, the radiographs were taken. In the third series -double contrast- the barium sulfate, which was obtained from each dog using a catheter, was substituted by a volume of air equal to that obtained from the contrast medium. Later the radiographs were taken in both projections. The radiographic plates of each series were analized comparing the characteristics of: radiographic density, outline and volume. With the pneumocolon barium enema and double contrast, the radiographic density was, in most cases, low, high and inter-mediate respectively. The radiographic outline was, in most cases, regular for the three techniques. Thee radiographic volume was similar in all of the series. From the results obtained, it is concluded that double contrast best outlines the intestinal mucosa and more information can be obtained from it [es

  14. Effect of mucolytic pretreatment on gastric mucosal coating with barium sulfate in the rat

    International Nuclear Information System (INIS)

    Lindgren, I.; Nevalainen, T.; Maeki, J.; Soederstroem, K.-O.

    1980-01-01

    Freshly prepared isolated rat stomachs were used to examine the adherence of barium sulfate particles to the mucosal surface by scanning electron microscopy. The stomachs were pretreated with sodium bicarbonate alone or in connection with N-acetyl-L-cysteine and then treated with barium sulfate specially designed for double contrast examination of the stomach. The best adhesion of the contrast medium was obtained when the mucosa was pretreated with both the alkaline and mucolytic agent indicating that, for the optimum adherence of the contrast medium, the mucosal surface must be as clean as possible. (Auth.)

  15. Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, A. D.; Jones, B. J. P.; Nygren, D. R.; Adams, C.; Álvarez, V.; Azevedo, C. D. R.; Benlloch-Rodríguez, J. M.; Borges, F. I. G. M.; Botas, A.; Cárcel, S.; Carrión, J. V.; Cebrián, S.; Conde, C. A. N.; Díaz, J.; Diesburg, M.; Escada, J.; Esteve, R.; Felkai, R.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Freitas, E. D. C.; Goldschmidt, A.; Gómez-Cadenas, J. J.; González-Díaz, D.; Gutiérrez, R. M.; Guenette, R.; Hafidi, K.; Hauptman, J.; Henriques, C. A. O.; Hernandez, A. I.; Hernando Morata, J. A.; Herrero, V.; Johnston, S.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Losada, M.; Martín-Albo, J.; Martínez-Lema, G.; Martínez, A.; Monrabal, F.; Monteiro, C. M. B.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Palmeiro, B.; Para, A.; Pérez, J.; Querol, M.; Repond, J.; Renner, J.; Riordan, S.; Ripoll, L.; Rodríguez, J.; Rogers, L.; Santos, F. P.; dos Santos, J. M. F.; Simón, A.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J. F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J. F. C. A.; Webb, R.; White, J. T.; Yahlali, N.

    2018-03-01

    A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\\sim$2~nm), and detected with a statistical significance of 12.9~$\\sigma$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

  16. Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

    Science.gov (United States)

    McDonald, A. D.; Jones, B. J. P.; Nygren, D. R.; Adams, C.; Álvarez, V.; Azevedo, C. D. R.; Benlloch-Rodríguez, J. M.; Borges, F. I. G. M.; Botas, A.; Cárcel, S.; Carrión, J. V.; Cebrián, S.; Conde, C. A. N.; Díaz, J.; Diesburg, M.; Escada, J.; Esteve, R.; Felkai, R.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Freitas, E. D. C.; Goldschmidt, A.; Gómez-Cadenas, J. J.; González-Díaz, D.; Gutiérrez, R. M.; Guenette, R.; Hafidi, K.; Hauptman, J.; Henriques, C. A. O.; Hernandez, A. I.; Hernando Morata, J. A.; Herrero, V.; Johnston, S.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Losada, M.; Martín-Albo, J.; Martínez-Lema, G.; Martínez, A.; Monrabal, F.; Monteiro, C. M. B.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Palmeiro, B.; Para, A.; Pérez, J.; Querol, M.; Repond, J.; Renner, J.; Riordan, S.; Ripoll, L.; Rodríguez, J.; Rogers, L.; Santos, F. P.; dos Santos, J. M. F.; Simón, A.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J. F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J. F. C. A.; Webb, R.; White, J. T.; Yahlali, N.; NEXT Collaboration

    2018-03-01

    A new method to tag the barium daughter in the double-beta decay of Xe 136 is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba++ ) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (˜2 nm ), and detected with a statistical significance of 12.9 σ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

  17. Effect of barium-coated halloysite nanotube addition on the cytocompatibility, mechanical and contrast properties of poly(methyl methacrylate) cement.

    Science.gov (United States)

    Jammalamadaka, Uday; Tappa, Karthik; Weisman, Jeffery A; Nicholson, James Connor; Mills, David K

    2017-01-01

    Halloysite nanotubes (HNTs) were investigated as a platform for tunable nanoparticle composition and enhanced opacity in poly(methyl methacrylate) (PMMA) bone cement. Halloysite has been widely used to increase the mechanical properties of various polymer matrices, in stark contrast to other fillers such as barium sulfate that provide opacity but also decrease mechanical strength. The present work describes a dry deposition method for successively fabricating barium sulfate nanoparticles onto the exterior surface of HNTs. A sintering process was used to coat the HNTs in barium sulfate. Barium sulfate-coated HNTs were then added to PMMA bone cement and the samples were tested for mechanical strength and tailored opacity correlated with the fabrication ratio and the amount of barium sulfate-coated HNTs added. The potential cytotoxic effect of barium-coated HNTs in PMMA cement was also tested on osteosarcoma cells. Barium-coated HNTs were found to be completely cytocompatible, and cell proliferation was not inhibited after exposure to the barium-coated HNTs embedded in PMMA cement. We demonstrate a simple method for the creation of barium-coated nanoparticles that imparted improved contrast and material properties to native PMMA. An easy and efficient method for coating clay nanotubes offers the potential for enhanced imaging by radiologists or orthopedic surgeons.

  18. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  19. Comparison between CT Colonography and Double-Contrast Barium Enema for Colonic Evaluation in Patients with Renal Insufficiency

    International Nuclear Information System (INIS)

    Chung, Sun Young; Park, Seong Ho; Lee, Seung Soo; Lee, Ju Hee; Kim, Ah Young; Park, Su Ki; Han, Duck Jong; Ha, Hyun Kwon

    2012-01-01

    To compare the CT colonography (CTC) and double-contrast barium enema (DCBE) for colonic evaluation in patients with renal insufficiency. Two sequential groups of consecutive patients with renal insufficiency who had a similar risk for colorectal cancer, were examined by DCBE (n = 182; mean ± SD in age, 51 ± 6.4 years) and CTC (n = 176; 50 ± 6.7 years), respectively. CTC was performed after colon cleansing with 250-mL magnesium citrate (n = 87) or 4-L polyethylene glycol (n = 89) and fecal tagging. DCBE was performed after preparation with 250-mL magnesium citrate. Patients with colonic polyps/masses of ≥ 6 mm were subsequently recommended to undergo a colonoscopy. Diagnostic yield and positive predictive value (PPV) for colonic polyps/masses, examination quality, and examination-related serum electrolyte change were retrospectively compared between the two groups. Both the CTC and DCBE were positive for colonic polyps/masses in 28 (16%) of 176 and 11 (6%) of 182 patients, respectively (p = 0.004). Among patients with positive findings, 17 CTC and six DCBE patients subsequently underwent a colonoscopy and yielded a PPV of 88% (15 of 17 patients) and 50% (3 of 6 patients), respectively (p = 0.089). Thirteen patients with adenomatous lesions were detected in the CTC group (adenocarcinoma [n = 1], advanced adenoma [n = 6], and non-advanced adenoma [n = 6]), as compared with two patients (each with adenocarcinoma and advanced adenoma) in the DCBE group (p = 0.003). Six (3%) of 176 CTC and 16 (9%) of 182 DCBE examinations deemed to be inadequate (p 0.046). Electrolyte changes were similar in the two groups. In patients with renal insufficiency, CTC has a higher diagnostic yield and a marginally higher PPV for detecting colorectal neoplasia, despite a similar diagnostic yield for adenocarcinoma, and a lower rate of inadequate examinations as compared with DCBE.

  20. Comparison between CT colonography and double-contrast barium enema for colonic evaluation in patients with renal insufficiency.

    Science.gov (United States)

    Chung, Sun-Young; Park, Seong Ho; Lee, Seung Soo; Lee, Ju Hee; Kim, Ah Young; Park, Su-Kil; Han, Duck Jong; Ha, Hyun Kwon

    2012-01-01

    To compare the CT colonography (CTC) and double-contrast barium enema (DCBE) for colonic evaluation in patients with renal insufficiency. Two sequential groups of consecutive patients with renal insufficiency who had a similar risk for colorectal cancer, were examined by DCBE (n = 182; mean ± SD in age, 51 ± 6.4 years) and CTC (n = 176; 50 ± 6.7 years), respectively. CTC was performed after colon cleansing with 250-mL magnesium citrate (n = 87) or 4-L polyethylene glycol (n = 89) and fecal tagging. DCBE was performed after preparation with 250-mL magnesium citrate. Patients with colonic polyps/masses of ≥ 6 mm were subsequently recommended to undergo a colonoscopy. Diagnostic yield and positive predictive value (PPV) for colonic polyps/masses, examination quality, and examination-related serum electrolyte change were retrospectively compared between the two groups. Both the CTC and DCBE were positive for colonic polyps/masses in 28 (16%) of 176 and 11 (6%) of 182 patients, respectively (p = 0.004). Among patients with positive findings, 17 CTC and six DCBE patients subsequently underwent a colonoscopy and yielded a PPV of 88% (15 of 17 patients) and 50% (3 of 6 patients), respectively (p = 0.089). Thirteen patients with adenomatous lesions were detected in the CTC group (adenocarcinoma [n = 1], advanced adenoma [n = 6], and non-advanced adenoma [n = 6]), as compared with two patients (each with adenocarcinoma and advanced adenoma) in the DCBE group (p = 0.003). Six (3%) of 176 CTC and 16 (9%) of 182 DCBE examinations deemed to be inadequate (p = 0.046). Electrolyte changes were similar in the two groups. In patients with renal insufficiency, CTC has a higher diagnostic yield and a marginally higher PPV for detecting colorectal neoplasia, despite a similar diagnostic yield for adenocarcinoma, and a lower rate of inadequate examinations as compared with DCBE.

  1. Comparison of transvaginal sonography and double-contrast barium enema for diagnosing deep infiltrating endometriosis of the posterior compartment.

    Science.gov (United States)

    Savelli, L; Manuzzi, L; Coe, M; Mabrouk, M; Di Donato, N; Venturoli, S; Seracchioli, R

    2011-10-01

    To compare the diagnostic accuracy of transvaginal sonography (TVS) and double-contrast barium enema (DCBE) in the preoperative detection of deep infiltrating endometriosis (DIE) of the posterior compartment. This was a prospective study of 69 consecutive patients with results of pelvic examination or symptoms suggestive of DIE of the posterior compartment. TVS and DCBE were performed before surgery by two groups of physicians specialized in endometriosis, each blinded to the results of the other technique. Imaging data were compared with histopathologic analysis of the resected specimen (gold standard). Sensitivity, specificity, positive and negative predictive values and test accuracies were calculated for both imaging modalities. Sixty seven of the 69 women had a nodule of DIE confirmed at laparoscopy and histopathologic examination. TVS diagnosed DIE in 57 (85%) of these patients, while DCBE revealed the presence of the lesion in 24 (36%) women. For the diagnosis of posterior DIE, TVS and DCBE had, respectively, a sensitivity of 85% and 36%, specificity of 100% and 100%, positive predictive value of 100% and 100%, negative predictive value of 17% and 4% and accuracy of 85.5% and 38%. In patients with pure bowel DIE the sensitivity was 91% and 43%, specificity was 100% and 100%, positive predictive value was 100% and 100%, negative predictive value was 29% and 6% and accuracy was 91% and 45%, respectively. TVS has a much higher sensitivity than does DCBE in detecting the presence of posterior DIE and should thus be regarded as the imaging modality of choice when there is clinical suspicion of the disease. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  2. Effect of barium-coated halloysite nanotube addition on the cytocompatibility, mechanical and contrast properties of poly(methyl methacrylate cement

    Directory of Open Access Journals (Sweden)

    Jammalamadaka U

    2017-06-01

    Full Text Available Uday Jammalamadaka,1 Karthik Tappa,1 Jeffery A Weisman,1 James Connor Nicholson,2 David K Mills1,3 1Center for Biomedical Engineering and Rehabilitation Science, 2Nanosystems Engineering, 3The School of Biological Sciences, Louisiana Tech University, Ruston, LA, USA Abstract: Halloysite nanotubes (HNTs were investigated as a platform for tunable nanoparticle composition and enhanced opacity in poly(methyl methacrylate (PMMA bone cement. Halloysite has been widely used to increase the mechanical properties of various polymer matrices, in stark contrast to other fillers such as barium sulfate that provide opacity but also decrease mechanical strength. The present work describes a dry deposition method for successively fabricating barium sulfate nanoparticles onto the exterior surface of HNTs. A sintering process was used to coat the HNTs in barium sulfate. Barium sulfate-coated HNTs were then added to PMMA bone cement and the samples were tested for mechanical strength and tailored opacity correlated with the fabrication ratio and the amount of barium sulfate-coated HNTs added. The potential cytotoxic effect of barium-coated HNTs in PMMA cement was also tested on osteosarcoma cells. Barium-coated HNTs were found to be completely cytocompatible, and cell proliferation was not inhibited after exposure to the barium-coated HNTs embedded in PMMA cement. We demonstrate a simple method for the creation of barium-coated nanoparticles that imparted improved contrast and material properties to native PMMA. An easy and efficient method for coating clay nanotubes offers the potential for enhanced imaging by radiologists or orthopedic surgeons. Keywords: barium, bone cement, halloysite, imaging, PMMA, sintering

  3. Barium enema (image)

    Science.gov (United States)

    A barium enema is performed to examine the walls of the colon. During the procedure, a well lubricated enema tube is inserted gently into the rectum. The barium, a radiopaque (shows up on X-ray) contrast ...

  4. Effects of barium sulfate as a contrast medium to enterocutaneous fistulas

    International Nuclear Information System (INIS)

    Pelster, F.W.; Reichelt, S.; Arndt, M.; Eising, E.G.

    1989-01-01

    Fistulation following thoracic and epigastric interventions are conservatively treated, as a rule, because of the high rate of complications expected from reoperation. With properly functioning anastomotic transit, insufficiencies usually undergo spontaneous healing, within four to six weeks. Enterocutaneous fistulae developed in 29 of 271 patients with intrathoracic oesophagastric or oesophagojejunal anastomosis. Syringeal ramification into pleural or abdominal cavities were eliminated by means of an absorbable contrast medium, before barium sulphate was orally administered to all patients. Thoracic fistulae were closed after 21.8 days on average, while 20.3 days was the average period required for closure of epigastric fistulae. Barium sulphate was found to stimulate fistular tissue granulation, so that obliteration of the fistular system occurred much sooner, as compared to conservative treatment. The patient's quality of life can thus be improved, and hospitalisation can be shortened. Neither locally delimited nor systemic complications were observed in any of the cases described. (author)

  5. Adverse effects and complications related to the use of barium sulphate contrast media for radiological examinations of the gastrointestinal tract - a literature review

    International Nuclear Information System (INIS)

    Periard, M.A.

    2003-01-01

    Barium sulphate is considered a safe and efficacious contrast medium that is routinely used for radiologic examinations of the gastrointestinal tract. Although the examinations rarely result in complications, the technique is moderately invasive and not entirely innocuous. Complications resulting from the procedures, and adverse reactions from the barium itself, have ranged from mild to severe and in rare instances have led to patient death. This paper reviews the clinical application, biological requirements and clinical properties of barium sulphate contrast media used in diagnostic x-ray imaging. It also outlines the risk factors and associated adverse reactions and complications involved with the use of barium sulphate, and presents documented cases where iatrogenic injuries have resulted. (author)

  6. Improved X-ray diagnosis of stomach by progress in the development of contrast media and examination techniques

    International Nuclear Information System (INIS)

    Lotz, W.

    1982-01-01

    Three factors have been responsible for the advances during the past few years in X-ray examination of the stomach: Improvement of the contrast media used; introduction of the rare-earth foils; and examination techniques imaging all sections of the stomach and of the duodenal bulb under hypotension in double-contrast technique, in complete filling, and imaging the accessible sections by means of proper compression. An interesting technique employs a combination of two different barium sulphate suspension used at the same time, e.g. Bubbly Barium or some other barium sulphate preparation with a small amount of High-Density Barium yielding excellent image of the gastric mucosa (technique with two contrast media). (orig.) [de

  7. Improvements in gastric diagnosis by using high density contrast media with low viscosity

    International Nuclear Information System (INIS)

    Toischer, H.P.

    1983-01-01

    In a retrospective clinical study, 150 unselected double contrast examinations of the stomach using conventional contrast media (100 g/100 ml barium sulphate) were compared with a similar number of examinations using a high density contrast medium of flow viscosity (250 g/100 ml barium sulphate). The high density contrast medium was distinctly better for demonstrating detail of the gastric mucosa. The uneveness of coating and instability of the older high density contrast media was observed in 15.5% of cases and, in no instance, did this make it impossible to reach a diagnosis. (orig.) [de

  8. Modified double contrast-enhanced examination of the stomach of adipose patients after vertical gastroplasty

    International Nuclear Information System (INIS)

    Raissaki, M.T.; Prassopoulos, P.; Hatjidakis, A.A.; Christodoulakis, M.; Melissas, J.; Gourtsoyiannis, N.C.

    1995-01-01

    The study reported covers 28 patients who were examined once by radiology before surgery, and twice after surgery. The first post-surgery examination was done on days 5-7, the second during the 4th until 6th month after surgery. For the first examination, water-soluble contrast agent was initially applied, then barium containing contrast agent. The second examination was done by modified double contrast technique. The most frequent, pre-surgery findings revealed gastro-esophageal reflux in 13 patients. The first post-surgery control detected a somastenosis in 2 patients, while the second control examination detected complications of various nature in 11 patients and gastro-esophageal reflux in 5 patients. In 6 patients, discrepancy between clinical and radiological findings was stated. The pouch size did not correlate with the frequency of complications, or with the body-to-mass index decrease. The examination method proposed in this article yields pre-surgery information on the anatomy of the stomach, more accurate dewscription of post-surgery complications, and better evaluation of the antireflux effect of the vertical gastroplasty. (orig.) [de

  9. Choice of double contrast barium enema (DCBE) method based on patient exposure dose

    Energy Technology Data Exchange (ETDEWEB)

    Bartal, G; Ben Hasid, I [Hillel Yaffe Medical Center, Hadera (Israel)

    1997-11-16

    Morbidity of colon cancer continues to increase, taking second and third places in malignant tumors. The incidence of colorectal cancer (CRC) increases exponentially with age; those over 50 years of age represent 37% of general population, yet account for 95% of the cases, and more than 96% of the deaths from colon malignancies For a long time radiologic examinations were considered as a main pre-operative diagnostic method for cancer of the colon. The sensitivity of the barium enema with regard to diagnosis of the carcinoma and polyps ranges from 92-98.5%. Sigmoidoscopy for detection and removal of polyps has been shown to decrease the incidence of subsequent CRC`s by 70-80% in distal colon. However, the sigmoid colon is often difficult to examine because of associated diverticular disease, and about 15% of tumors in the sigmoid colon are overlooked. (Authors)

  10. Choice of double contrast barium enema (DCBE) method based on patient exposure dose

    International Nuclear Information System (INIS)

    Bartal, G.; Ben Hasid, I.

    1997-01-01

    Morbidity of colon cancer continues to increase, taking second and third places in malignant tumors. The incidence of colorectal cancer (CRC) increases exponentially with age; those over 50 years of age represent 37% of general population, yet account for 95% of the cases, and more than 96% of the deaths from colon malignancies For a long time radiologic examinations were considered as a main pre-operative diagnostic method for cancer of the colon. The sensitivity of the barium enema with regard to diagnosis of the carcinoma and polyps ranges from 92-98.5%. Sigmoidoscopy for detection and removal of polyps has been shown to decrease the incidence of subsequent CRC's by 70-80% in distal colon. However, the sigmoid colon is often difficult to examine because of associated diverticular disease, and about 15% of tumors in the sigmoid colon are overlooked. Authors)

  11. Comparison of Gastrografin to barium sulfate as a gastrointestinal contrast agent in red-eared slider turtles (Trachemys scripta elegans).

    Science.gov (United States)

    Long, Charles Tyler; Page, Richard B; Howard, Antwain M; McKeon, Gabriel P; Felt, Stephen A

    2010-01-01

    Red-eared slider turtles (Trachemys scripta elegans) commonly develop intestinal obstruction. The gastrointestinal transit time in turtles tends to be longer than in other animals, making a rapid diagnosis of obstruction difficult. Fifteen red-eared sliders were given either Gastrografin or 30% w/v barium sulfate orally to compare ease of administration, transit time, and image quality. Each contrast medium was easy to administer but barium sulfate had to be administered more slowly (mean = 40s) than Gastrografin (mean = 20s) to prevent regurgitation. The mean transit and emptying time of Gastrografin was at least 9 h faster than barium sulfate at all time points except gastric transit. Both contrast media had a smooth, uniform appearance that outlined the mucosa with well-defined margins within the stomach and proximal small intestine. Dilution of Gastrografin occurred as it progressed through the intestines, resulting in decreased opacity in the distal small intestine and colon. Pre-administration packed cell volume and total serum protein levels of four turtles receiving Gastrografin were compared with levels at 24-, 96-, and 168-hours postadministration as well as to four control turtles not receiving contrast medium. Packed cell volume and total serum protein levels did not significantly differ among the Gastrografin and control group. From a clinical perspective, administration of Gastrografin allows for quicker results with only minor hematologic changes in red-eared sliders, but visualization of this contrast medium in the lower gastrointestinal tract may be insufficient for an accurate diagnosis.

  12. Atrophic gastritis and enlarged gastric folds diagnosed by double-contrast upper gastrointestinal barium X-ray radiography are useful to predict future gastric cancer development based on the 3-year prospective observation.

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Ichinose, Masao; Takahashi, Yu; Minatsuki, Chihiro; Matsuda, Rie; Nakayama, Chiemi; Shimamoto, Takeshi; Kodashima, Shinya; Ono, Satoshi; Tsuji, Yosuke; Niimi, Keiko; Sakaguchi, Yoshiki; Kataoka, Yosuke; Saito, Itaru; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kaikimoto, Hikaru; Matsumoto, Yuta; Yamaguchi, Daisuke; Kageyama-Yahara, Natsuko; Fujishiro, Mitsuhiro; Wada, Ryoichi; Mitsushima, Toru; Koike, Kazuhiko

    2016-07-01

    Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is the standard gastric cancer screening method in Japan. Atrophic gastritis and enlarged gastric folds are considered the two major features of Helicobacter pylori-induced chronic gastritis, but the clinical meaning of evaluating them by UGI-XR has not been elucidated. We analyzed healthy UGI-XR examinees without a history of gastrectomy, previous Helicobacter pylori eradication and usage of gastric acid suppressants. Of the 6433 subjects, 1936 (30.1 %) had atrophic gastritis and 1253 (19.5 %) had enlarged gastric folds. During the 3-year prospective observational follow-up, gastric cancer developed in seven subjects, six of whom (85.7 %) had atrophic gastritis with H. pylori infection and five of whom (71.4 %) had enlarged gastric folds with H. pylori infection. The Kaplan-Meier method with log-rank testing revealed that both UGI-XR-based atrophic gastritis (p = 0.0011) and enlarged gastric folds (p = 0.0003) are significant predictors for future gastric cancer incidence.

  13. Pregnancy outcome after 1st-trimester inadvertent exposure to barium sulphate as a contrast media for upper gastrointestinal tract radiography.

    Science.gov (United States)

    Han, B H; Lee, K S; Han, J Y; Choi, J S; Ahn, H K; Ryu, H M; Yang, J H; Han, H W; Nava-Ocampo, A A

    2011-10-01

    Despite barium being used as a contrast media for decades, the specific assessment of its safety in pregnant women is scarce. We are reporting the favourable pregnancy outcome in women who were inadvertently exposed to barium swallow and associated ionising radiation, early in pregnancy. A control group of age- and gravidity-matched unexposed pregnant women was also included. There were 32 live-born babies in the exposed group and 94 in the control group. Women had undergone diagnostic upper gastrointestinal tract (UGT) fluoroscopic examination at 3.3 ± 1.5 weeks' gestation. Estimated maternal radiation dose secondary to barium swallow varied widely, the maximum dose was estimated to be 2.45 mSv. Similar pregnancy outcomes were observed between the groups. The number of babies born with major malformations was not significantly different (p = 1.0) between cases and controls: one (3.1%) vs three (3.2%), respectively. In conclusion, our small prospective cohort study of women suggests no association between inadvertent exposure to ionising radiation and barium sulphate during fluoroscopic barium swallow and adverse fetal outcomes.

  14. Qualitative analysis of barium particles coated in small intestinal mucosa of rabbit by using scanning electron microscopy

    International Nuclear Information System (INIS)

    Lee, Yong Suk; Ha, Hyun Kwon; Lee, Yang Seob; Kim, Jae Kyun; Yoon, Seong Eon; Kim, Jung Hoon; Chung, Dong Jin; Auh, Yong Ho

    1998-01-01

    To qualitatively analysed barium coating status in the intestinal mucosa, we used scanning electron microscopy to observe barium particles coated in the small intestinal mucosa of rabbit, and we attempted to assess the relationship between electron microscopic findings and radiographic densities. Six different combination of barium and methylcellulose suspensions were infused into the resected small intestines of 15 rabbits. Barium powders were mixed with water to make 40% and 70% w/v barium solutions, and also mixed with 0.5% methylcellulose solutions were used as a double contrast agent. After the infusion of barium suspensions, a mammography unit was used to obtain radiographs of the small intestine, and their optical densities were measured by a densitometer. Thereafter, photographs of barium-coated small intestinal mucosa were obtained using a scanning electron microscope (x 8,000), and the number of barium particles in the unit area were measured. To compare the relationship between the electron microscopic findings and optical densities, statistical analysis using Spearman correlation was performed. This study shows that by using scanning electron microscopy, barium particles coated on the small intestinal mucosa can be qualitatively analysed. It also shows that the number of small barium particles measured by scanning electron microscopy is related to optical densities. (author). 14 refs., 2 figs

  15. Barium peritonitis following upper gastrointestinal series: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook [Soonchunhyang University College of Medicine, Seoul Hospital, Seoul (Korea, Republic of)

    2017-06-15

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly.

  16. Barium peritonitis following upper gastrointestinal series: A case report

    International Nuclear Information System (INIS)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook

    2017-01-01

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly

  17. Radiographic anatomy and barium sulfate contrast transit time of the gastrointestinal tract of bearded dragons (Pogona vitticeps).

    Science.gov (United States)

    Grosset, Claire; Daniaux, Lise; Guzman, David Sanchez-Migallon; Weber, Ernest Scott; Zwingenberger, Allison; Paul-Murphy, Joanne

    2014-01-01

    The positive contrast gastrointestinal study is a common non-invasive diagnostic technique that does not require anesthesia and enables good visualization of the digestive tract. Radiographic anatomy and reference intervals for gastrointestinal contrast transit time in inland bearded dragons (Pogona vitticeps) were established using seven animals administered 15 ml/kg of a 35% w/v suspension of barium by esophageal gavage. Dorso-ventral and lateral radiographic views were performed at 0, 15, 30 min, 1, 2, 4, 6, 8, 12 h, and then every 12 h up to 96 h after barium administration. Gastric emptying was complete at a median time of 10 h (range 4-24 h). Median jejunum and small intestinal emptying times were 1 h (range 30 min-2 h) and 29 h (range 24-48 h), respectively. Median transit time for cecum was 10 h (range 8-12 h). Median time for contrast to reach the colon was 31 h (range 12-72 h) after administration. Results were compared to those obtained in other reptilian species. This technique appeared safe in fasted bearded dragons and would be clinically applicable in other lizard species.

  18. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases

    International Nuclear Information System (INIS)

    Gispert, S.; Mayolas, N.; Hidalgo, A.

    2003-01-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs

  19. Comparative analysis of upper gastrointestinal endoscopy, double-contrast upper gastrointestinal barium X-ray radiography, and the titer of serum anti-Helicobacter pylori IgG focusing on the diagnosis of atrophic gastritis.

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Takahashi, Yu; Minatsuki, Chihiro; Nakayama, Chiemi; Matsuda, Rie; Shimamoto, Takeshi; Takeuchi, Chihiro; Kodashima, Shinya; Ono, Satoshi; Tsuji, Yosuke; Fujishiro, Mitsuhiro; Wada, Ryoichi; Mitsushima, Toru; Koike, Kazuhiko

    2016-04-01

    Upper gastrointestinal endoscopy (UGI-ES) and double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) are two major image-based methods to diagnose atrophic gastritis, which is mostly induced by Helicobacter pylori infection. However, there have been few studies directly comparing them. Atrophic gastritis was evaluated using the data of 962 healthy subjects who underwent UGI-ES and UGI-XR within 1 year. Based on UGI-ES and UGI-XR, 602 subjects did not have atrophic gastritis and 254 subjects did have it. Considering UGI-ES-based atrophic gastritis as the standard, sensitivity and specificity of UGI-XR-based atrophic gastritis were 92.0 % (254/276) and 92.8 % (602/649), respectively. The seven-grade Kimura-Takemoto classification of UGI-ES-based atrophic gastritis showed a strong and significant association with the four-grade UGI-XR-based atrophic gastritis. Sensitivity and specificity of serum anti-Helicobacter pylori IgG to detect UGI-ES/UGI-XR-based atrophic gastritis were 89.4 % (227/254) and 99.8 % (601/602), indicating that atrophic gastritis can be overlooked according to serum anti-Helicobacter pylori IgG alone.

  20. Comparison of three contrast radiographic techniques in the dog large intestine; Comparacion de tres tecnicas radiograficas de contraste en el intestino grueso del perro

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, L.; Thibaut, J.; Olhaberry, E.; Born, R.; Deppe, R. [Universidad Austral de Chile, Valdivia (Chile)

    1994-07-01

    In order to compare three radiographic techniques -pneumocolon, barium enema and double contrast- in the large intestine of the dog, three radiographic series in ventrodorsal and right lateral projections were taken. Six healthy adult dogs of both sexes with an approximate weight between 5 to 10 kg were used. Three enemas were administered 24, 12 and 2 hrs. before the series of radiographs were taken. Then dogs were anaesthetized with sodium tiopental (20 mg/kg iv) and the contrast media were introduced. Pneumocolon was carried out in the first series introducing air (20 cc/kg) in the large intestine through a Foley rectal catheter. Radiographs were taken in both projections, after 5 and 15min. respectively. Barium enema was performed in the second series introducing barium sulfate (18%) in the large intestine through a Foley rectal catheter (25 cc/kg); 5 and 15 min. later, the radiographs were taken. In the third series -double contrast- the barium sulfate, which was obtained from each dog using a catheter, was substituted by a volume of air equal to that obtained from the contrast medium. Later the radiographs were taken in both projections. The radiographic plates of each series were analized comparing the characteristics of: radiographic density, outline and volume. With the pneumocolon barium enema and double contrast, the radiographic density was, in most cases, low, high and inter-mediate respectively. The radiographic outline was, in most cases, regular for the three techniques. Thee radiographic volume was similar in all of the series. From the results obtained, it is concluded that double contrast best outlines the intestinal mucosa and more information can be obtained from it [Spanish] Con la finalidad de comparar tres tecnicas radiograficas del intestino grueso del perro -neumocolon, enema baritado y doble contraste-, se tomaron tres series radiograficas en proyeccion ventrodorsal y lateral derecha en 6 perros adultos, de 5 a 10 kg de peso, que

  1. Barium Sulfate

    Science.gov (United States)

    ... uses a computer to put together x-ray images to create cross-sectional or three dimensional pictures of the inside of the body). Barium sulfate is in a class of medications called radiopaque contrast media. It works by coating the esophagus, stomach, or ...

  2. Gastrointestinal tract wall visualization and distention during abdominal and pelvic multidetector CT with a neutral barium sulphate suspension: comparison with positive barium sulphate suspension and with water.

    Science.gov (United States)

    Oliva, M R; Erturk, S M; Ichikawa, T; Rocha, T; Ros, P R; Silverman, S G; Mortele, K J

    2012-01-01

    When examining patients with contrast-enhanced multidetector-row CT, we determined if the stomach and small bowel were visualized and distended better with a neutral barium sulphate suspension than with positive barium sulphate suspension or water. After obtaining approval from our institutional review board, 156 patients (women: 84; mean age: 54 yrs) with no history of gastrointestinal tract disease were randomized prospectively to receive orally either 900 ml of neutral (0.1% w/v) barium sulphate suspension (n = 53), 900 ml of positive (2.1% w/v) barium sulphate suspension (n = 53), or 900 ml of water (n = 50), prior to undergoing contrast-enhanced abdominal and pelvic multidetector-row CT. Two independent radiologists evaluated the stomach, and small bowel, for luminal distension and wall visualization, using a five point scale. Results were compared using Kruskal-Wallis and Mann-Whitney U tests. The walls of the stomach, and small bowel were visualized better in patients who were administered neutral barium sulphate suspension than those who were administered either positive barium sulphate suspension (p barium sulphate suspension, the stomach and small bowel were distended better compared to patients administered water (p barium sulphate suspension (p contrast-enhanced abdominal and pelvic multidetector-row CT, orally administered neutral barium sulphate suspension allows the gastrointestinal tract to be visualized and distended better than either positive barium sulphate suspension, or water.

  3. Improved radiological diagnosis in the stomach by means of an improved contrast material

    International Nuclear Information System (INIS)

    Lotz, W.; Liebenow, S.

    1979-01-01

    Our experience with a cheap contrast medium, which we prepare ourselves, is described, stretching over a period of 18 months. It is based on the bubbly barium first described by Op den Orth and is made by means of carbone dioxide in a soda water syphon. It is better for detailed contrast examination of the stomach than the commercially available contrast media. It is thought that this is due to optimal viscosity for wetting of the mucosa, optimal size of the barium sulphate particles, which are larger than one micron, and greater distension of the stomach due to greater quantities of CO 2 . The use of bubbly barium for routine examination of the stomach, using double contrast and hypotonia with graded compresseion, almost always results in demonstration of the areae gastricae in large parts of the stomach. We regard this as a sign of a good examination, since we are then able to demonstrate small lesions such as complete or incomplete erosions, ulcer scars of flat ulcers. (orig.) [de

  4. An experimental study on barium peritonitis in rats

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    Barium sulfate is universally used contrast media in gastrointestinal roentgenology, and spillage of barium into peritoneal cavity can occur. The references on effect of barium sulfate in the peritoneal cavity have been scattered and the results are varied. In 80 rats, body weight of 130 gm to 150 gm, sterile pure barium, sterile commercial barium, intestinal content, and mixed pure barium and intestinal content were experimentally injected into the peritoneal cavity. Consecutive weekly laparotomy and microscopic examination were done for 4 weeks. The results are as followings: 1. Mind inflammatory reaction and mild adhesion after sterile pure barium injection. 2. Mild inflammatory reaction and moderate adhesion after sterile commercial barium injection. 3. Acute peritonitis and abscess formation after intestinal content injection. 4. High mortality due to severe acute peritonitis, and severe adhesion in survivors after injection of both pure barium and intestinal content.

  5. Examination of the gastrointestinal tract using the tussian X-ray contrast substance BAR-VIPS based on barium sulfate

    International Nuclear Information System (INIS)

    Ratobyl'skij, G.V.; Kaluzhskij, A.A.

    1997-01-01

    Results of X-ray studies of gastrointestinal tract using domestic X-ray contrast preparation based on barium sulfate BAR-VIPS developed by VIPS-MED company (t. Fryazino, Moscow region). Testing of the preparation has shown that BAR-VIPS permits to diagnose every pathological changes in esophagus, stomach, rectum, small intestine as well as to diagnose successfully large intestine diseases

  6. Iopamidol as an oral contrast media for computed tomography: a taste comparison to iohexol, diatrizoate sodium, and barium sulfate.

    Science.gov (United States)

    Rogers, Douglas; Sheth, Chandni; Eisenmenger, Laura; Mignogna, Eugene; Winter, Thomas

    2017-12-01

    The objective of this study is to compare the palatability of iopamidol and iohexol. This was a blinded and randomized trial in which fifty healthy subjects taste tested iopamidol (Isovue, Bracco Diagnostics), iohexol (Omnipaque, GE Healthcare), diatrizoate meglumine and diatrizoate sodium solution (Gastrografin, Bracco Diagnostics), and barium sulfate suspension 2.1% w/v, 2.0% w/w (READI-CAT2, E-Z-EM). Participants scored palatability on a continuous scale from 0 to 40 (0 = intolerable, 10 = unpleasant but tolerable, 20 = neutral, 30 = kind of like, 40 = strongly like). Mean scores (SD/SEM) for the contrast agents (n = 50) were iopamidol = 21.0 (8.4/1.2); iohexol = 21.8 (7.1/1.0); Gastrografin = 16.8 (9.6/1.4); and barium = 23.7 (9.1/1.3). One-way ANOVA equality of means test shows rejection of the hypothesis that the means are equal (F* = 6.550, p = .000). Post hoc testing demonstrates Gastrografin to be significantly less preferred to barium (p = .000) and iohexol (p = .012). No difference was found between iopamidol and iohexol (p = .959). One-way ANOVA equality of means test of just iopamidol, iohexol, and barium does not reject the hypothesis that means are equal (F* = 1.778 and p = .174). There is no significant difference in palatability between iopamidol and iohexol, supporting the use of iopamidol as a viable alternative to iohexol as an oral contrast agent.

  7. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs

    International Nuclear Information System (INIS)

    Thibaut, J.; Parada, E.; Vargas, L.; Deppe, R.; Born, R.

    1997-01-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [es

  8. Gluten content of barium sulfate suspensions used for barium swallows in patients with celiac disease.

    Science.gov (United States)

    Chiu, Jennifer G; Shin, Yoona; Patel, Priti N; Mangione, Robert A

    2014-01-01

    To determine the availability and accuracy of information provided by hospitals, imaging centers, and manufacturers regarding gluten in barium sulfate suspensions. A total of 105 facilities were contacted via telephone to determine the gluten content of the contrast media used in those facilities. Manufacturers were contacted and their Web sites reviewed to determine the gluten content of their barium products. Thirty-nine percent of the hospitals and 52% of the imaging centers were not aware of the gluten content of the contrast media they used. Twenty-nine-and-a-half percent of the respondents provided the correct gluten content. The manufacturers noted that 5 products were tested and confirmed gluten free, 1 product was not tested but described as gluten free, 1 product's gluten content depended upon its flavor, and 1 product was reported to contain gluten. Clinicians caring for patients with celiac disease or patients who choose to restrict their gluten consumption must ensure that the barium sulfate suspension ingested is gluten free. It can be difficult to determine the gluten content of barium sulfate, as a majority of radiology departments and imaging centers did not know whether the product they use is gluten free. Educating staff members and improving product labeling would benefit the quality of care provided to patients with celiac disease.

  9. The double contrast examination of the colon

    International Nuclear Information System (INIS)

    Welin, S.; Welin, G.

    1980-01-01

    The double contrast method has been modified in order to get a more detailed picture of the mucous membrane of the colon. The method has been employed at Malmoe hospital since 1953. The method and its diagnostic application in cases of adenoids, villiferous tumours, diverticula, Crohn's disease, ulcerating colitis, and deformation of the rectum/sigma junction due to external endometriosis and peritoneal carcinosis are described. The diagnostic values of the double contrast method and colposcopy/biopsy of the colon are compared. The two methods are found to be complementary. (MG) [de

  10. A new anastomotic leakage model in circular double stapled colorectal anastomosis after low anterior rectum resection in pigs.

    Science.gov (United States)

    Wenger, F A; Szucsik, E; Hoinoiu, B F; Ionac, M; Walz, M K; Schmid, K W; Reis, H

    2013-12-01

    A high incidence of anastomotic leakage (37.5%) is reported after low anterior rectal resection (LAR) and circular double-stapled anastomosis without protective ileostoma. Since the pathomechanism of anastomosis leakage is still unclear, a suitable animal model would be most desirable. The objective was to assess the incidence of clinically apparent and inapparent leakage after LAR in pigs (n = 20). Endpoints were radiological, clinical, macroscopic, and histologic proof of anastomotic leakage on the 9th postoperative day. Integrity of anastomosis was assessed by double-contrast barium examination on 9th postoperative day. Animals were sacrificed and anastomoses were resected for histopathological investigation. In case of earlier clinical apparent anastomotic leakage, radiologic double-contrast barium was performed immediately. LAR with a circular double-stapled anastomosis without protective ileostoma was performed in 20 pigs (m:f = 8:12). Length of resection was 10-20 cm, anastomosis was performed 7 cm ab ano. Five animals (25%) developed clinical apparent anastomotic leakage (no appetite, fever, inactivity, tachypnea, discomfort, pain) between the 6th (n = 1) and 9th (n = 4) postoperative day, proven by double-contrast barium radiographs. Additionally in 1 animal clinical inapparent anastomotic insufficiency was observed radiologically. Total rate of leakage was 30% (n = 6). These results were confirmed by leucocytosis, low potassium levels, in two cases high ALT and AST and local peritonitis in all cases. Including one additional case of clinical inapparent leakage, total rate of anastomotic leakage was 30% (6/20). Thus we managed to establish a new experimental model of anastomotic leakage after low rectal resection comparable to the human situation.

  11. M series resonant x-ray lines of barium for near threshold electron excitation

    International Nuclear Information System (INIS)

    Morgon, D.V.

    1992-01-01

    An investigation of the M series resonant x-ray emission lines of barium for near threshold electron excitation was undertaken with a vacuum double crystal spectrometer equipped with potassium acid phthalate crystals. X-ray continuum isochromats were obtained for barium samples using the double crystal spectrometer as a monochrometer set to pass 532 eV photons. The rotatable anode allowed the samples to be observed by either the double crystal spectrometer or a soft x-ray appearance potential spectrometer, which was used for monitoring the surface of the varium sample for contamination, and to provide a cross-check for the double crystal spectrometer data. Barium M series characteristic x-ray spectra for 2.0 keV electron excitation were obtained for a variety of samples, and it was discovered that the fluorescent and resonant x-ray emission line energies remained virtually the same, regardless of the chemical condition of the sample. The continuum resonance effect was observed for near-threshold energy electron excitation, but it was significantly weaker than the same effect observed previously for lanthanum or cerium. The electron excitation energy and intensity of this effect were strongly dependent on the chemical condition of the barium sample. X-ray continuum isochromats were observed for pure and contaminated barium samples at a photon energy of 532 eV. For pure metallic barium, a peak associated with 4f electronic states was observed at an energy of about 10.2 eV above the Fermi level. When the sample was exposed to 1.5 x 10 4 Langmuir of air, the 4f structure became more sharply peaked, and shifted to an energy of about 12.0 eV above the Fermi level. A continuum isochromat of barium oxide was also observed. Chemical shifts in barium M IV and M V appearance potential spectra are therefore caused soley by shifts in the energy position of the empty 4f electronic states relative to the Fermi level

  12. Single and double contrast arthrography in lesions of the glenohumeral joint

    International Nuclear Information System (INIS)

    Ahovuo, J.

    1984-01-01

    One hundred and forty-five arthrograms from single and double contrast arthrography were compared with respect to their accuracy in revealing lesions of the glenohumeral joint. Total and partial rotator cuff tears were accurately delineated by both single and double contrast arthrography. The size of the tear did not correlate with surgical findings with either technique. The volume of the injected contrast medium was larger in full-thickness rotator cuff tears than in normal arthrograms (p 2 test). No difference in filling frequency of the sheath could be observed between single and double contrast arthrography. This study did not reveal any major advantages of double contrast arthrography over single contrast examinations in lesions of the rotator cuff and those of the tendon of the long head of the biceps brachii. (orig.)

  13. Barium Tagging from nEXO Using Resonance Ionization Spectroscopy

    Science.gov (United States)

    Twelker, K.; Kravitz, S.

    nEXO is a 5-ton liquid enriched-xenon time projection chamber (TPC) to search for neutrinoless double-beta decay, designed to have the sensitivity to completely probe the inverted mass hierarchy of Majorana neutrinos. The detector will accommodate-as a background reduction technique-a system to recover and identify the barium decay product. This upgrade will allow a background-free measurement of neutrinoless double-beta decay and increase the half-life sensitivity of the experiment by at least one order of magnitude. Ongoing research and development includes a system to test barium extraction from liquid xenon using surface adsorption and Resonance Ionization Spectroscopy (RIS).

  14. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  15. Associated factors of atrophic gastritis diagnosed by double-contrast upper gastrointestinal barium X-ray radiography: a cross-sectional study analyzing 6,901 healthy subjects in Japan.

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Shimamoto, Takeshi; Minatsuki, Chihiro; Takahashi, Yu; Nakayama, Chiemi; Matsuda, Rie; Fujishiro, Mitsuhiro; Konno-Shimizu, Maki; Kato, Jun; Kodashima, Shinya; Ono, Satoshi; Niimi, Keiko; Mochizuki, Satoshi; Tsuji, Yosuke; Sakaguchi, Yoshiki; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kakimoto, Hikaru; Wada, Ryoichi; Mitsushima, Toru; Ichinose, Masao; Koike, Kazuhiko

    2014-01-01

    Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP) infection. We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach. Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880). These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β) and odds ratio (OR) demonstrated that serum HP IgG (β = 1.499, OR = 4.48), current smoking (β = 0.526, OR = 1.69), age (β = 0.401, OR = 1.49), low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40), and male gender (β = 0.306, OR = 1.36) showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (p<0.0001). Contrastively, UGI-XR-based atrophic gastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9%) and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%), which are not significantly different from gastric acid suppressant-free subjects. The presence of UGI-XR-based atrophic gastritis is positively

  16. Barium enema and CT volumetry for predicting pathologic response to preoperative chemoradiotherapy in rectal cancer patients.

    Science.gov (United States)

    Murono, Koji; Kawai, Kazushige; Tsuno, Nelson H; Ishihara, Soichiro; Yamaguchi, Hironori; Sunami, Eiji; Kitayama, Joji; Watanabe, Toshiaki

    2014-06-01

    Preoperative chemoradiotherapy has been widely used for the prevention of local recurrence of locally advanced rectal cancer, and the effect of chemoradiotherapy is known to be associated with overall survival. We aimed to evaluate the association of the pathologic response grade with tumor recurrence rate after chemoradiotherapy, using radiographic analysis and the Response Evaluation Criteria in Solid Tumors as the parameters. This study was conducted at a single tertiary care institution in Japan. This was a retrospective cohort study of patients undergoing preoperative chemoradiotherapy. A total of 101 low rectal cancer patients receiving preoperative chemoradiotherapy from July 2004 to August 2012 were enrolled. The tumor reduction rate was measured with the use of traditional Response Evaluation Criteria in Solid Tumors, barium enema, and CT volumetry, and the correlation between the reduction rate and the pathologic response grade was examined. The tumor reduction rate assessed according to Response Evaluation Criteria in Solid Tumors showed no association with the pathologic response grade (p =0.61). In contrast, the radiographic response rate by both barium enema and CT volumetry strongly correlated with the pathologic response grade (p volumetry had a lower recurrence rate (p =0.03, p =0.03, p =0.0002, and p =0.001). The difference between high responders and low responders was especially prominent by barium enema and CT volumetry. The study is limited by its retrospective nature. Double-contrast barium enema and CT volumetry were superior to Response Evaluation Criteria in Solid Tumors in evaluating the effect of chemoradiotherapy and predicting the likelihood of tumor recurrence.

  17. Anastomotic stenosis of the descending colon caused by barium granuloma formation following barium peritonitis: report of a case.

    Science.gov (United States)

    Kitajima, Toshihiro; Tomizawa, Kenji; Hanaoka, Yutaka; Toda, Shigeo; Matoba, Shuichiro; Kuroyanagi, Hiroya; Oota, Yasunori

    2014-11-01

    Anastomotic stricture reportedly often recurs following barium peritonitis, regardless of whether the anastomotic diameter is initially sufficient. However, the causes of repetitive stricture have not been clarified. We report a case that suggests the pathophysiology of recurrent anastomotic strictures following barium peritonitis. The patient was a 39-year-old Japanese man with idiopathic perforation of the descending colon after undergoing an upper gastrointestinal barium contrast study. After emergency peritoneal lavage and diverting colostomy, created using the perforated region, the patient recovered uneventfully and 3 months later, the colostomy was closed and the perforated colon was resected. However, 7 months after colostomy closure, abdominal distention gradually developed, and colonoscopy revealed an anastomotic stricture. The patient was referred to our hospital where he underwent resection of the anastomotic stricture. The surgical specimen exhibited barium granulomas not only in the subserosa of the entire specimen, but also in the submucosa and lamina propria localized in the anastomotic site. These findings suggest that barium was embedded in the submucosa and lamina propria with manipulation of the stapled anastomosis and that the barium trapped in the anastomotic site caused persistent inflammation, resulting in an anastomotic stricture.

  18. Comparative evaluation of the fecal-tagging quality in CT colonography: barium vs. iodinated oral contrast agent.

    Science.gov (United States)

    Nagata, Koichi; Singh, Anand Kumar; Sangwaiya, Minal Jagtiani; Näppi, Janne; Zalis, Michael E; Cai, Wenli; Yoshida, Hiroyuki

    2009-11-01

    The purpose of this evaluation was to compare the tagging quality of a barium-based regimen with that of iodine-based regimens for computed tomographic (CT) colonography. Tagging quality was assessed retrospectively in three different types of fecal-tagging CT colonographic cases: 24 barium-based cases, 22 nonionic iodine-based cases, and 24 ionic iodine-based cases. For the purpose of evaluation, the large intestine was divided into six segments, and the tagging homogeneity of a total of 420 segments (70 patients) was graded by three blinded readers from 0 (heterogeneous) to 4 (homogeneous). For barium-based cases, the average score for the three readers was 2.4, whereas it was 3.4 for nonionic iodine and 3.6 for ionic iodine. The percentages of segments that were assigned scores of 4 (excellent tagging [100%]) were 11.6%, 61.9%, and 72.9% for the barium-based, nonionic iodine-based, and ionic iodine-based regimens, respectively. The homogeneity scores of iodine-based fecal-tagging regimens were significantly higher than those of the barium-based fecal-tagging regimen (P barium-based regimen (P barium-based fecal-tagging regimen. Iodine-based fecal-tagging regimens can provide an appropriate method for use in nonlaxative or minimum-laxative CT colonography.

  19. Epinephrine inhanced double contrast knee arthrography

    International Nuclear Information System (INIS)

    Lee, Jae Mun; Choi, Byung Ihn

    1981-01-01

    It is well known that double contrast knee arthrography is useful in diagnosis of meniscal lesions and other knee pathology. But intra-articular structures become less well delineated shortly after injection into the knee joint with water soluble contrast media because of rapid absorption and dilution of the injected media. This limits the time when sharply detailed arthrograms are obtainable and precludes repeat delayed arthrogram without reinjection of contrast media. In order to overcome this major disadvantage, the authors used epinephrine which has vasoconstrictive effect and is expected to reduce fluid movement across the synovial membrane temporarily. The authors attempted to compare epinephrine inhanced double contrast arthrographic group, epinephrine(+) group, to the double contrast arthrographic group without epinephrine, epinephrine(-) group, by statistical evaluation. Each group consisted of 35 cases and 7 lateral films of knee joint were taken sequentially 2, 6, 10, 15, 20, 30, and 60 minutes after injection of contrast media, and were assessed by 5 certified radiologists. The results were as follows: 1. The difference of mean score of quality between epinephrine(+) group and epinephrine(-) group was statistically significant at every time interval (ρ value < 0.01 at 2 minutes, ρ < 0.001 at all other time intervals). Epinephrine(+) group was superior to the epinephrine(-) group in quality of film. 2. Numbers of cases above score of 2 which was considered to be of diagnostic quality in evaluating meniscal lesions were larger in epinephrine(+) group than epinephrine(-) group at every time interval. And the difference between two groups was highly significant statistically (ρ < 0.001). 3. Only 43% of cases was above score of 2 at 10 minutes in epinephrine(-) group, but 97% at 10 minutes and 80% at 20 minutes respectively in epinephrine(+) group. Therefore duration for adequate study of arthrogram is prolonged more than two times in epinephrine(+) group

  20. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  1. Gastric polyps diagnosed by double-contrast upper gastrointestinal barium X-ray radiography mostly arise from the Helicobacter pylori-negative stomach with low risk of gastric cancer in Japan.

    Science.gov (United States)

    Takeuchi, Chihiro; Yamamichi, Nobutake; Shimamoto, Takeshi; Takahashi, Yu; Mitsushima, Toru; Koike, Kazuhiko

    2017-03-01

    Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is a method broadly used for gastric cancer screening in Japan. Gastric polyp is one of the most frequent findings detected by UGI-XR, but how to handle it remains controversial. Gastric polyps of the 17,264 generally healthy subjects in Japan who underwent UGI-XR or upper gastrointestinal endoscopy (UGI-ES) in 2010 were analyzed. Of the 6,433 UGI-XR examinees (3,405 men and 3,028 women, 47.4 ± 9.0 years old), gastric polyps were detected in 464 men (13.6 %) and 733 women (24.2 %) and were predominantly developed on the non-atrophic gastric mucosa (p gastric polyps has significant association with lower value of serum anti-Helicobacter pylori IgG titer, female gender, lighter smoking habit, older age, and normal range of body mass index (≥18.5 and gastric cancer occurred in 7 subjects (0.11 %), but none of them had gastric polyps at the beginning of the follow-up period. Of the 2,722 subjects with gastric polyps among the 10,831 UGI-ES examinees in the same period, 2,446 (89.9 %) had fundic, 267 (9.8 %) had hyperplastic, and 9 (0.3 %) had adenomatous/cancerous polyps. Gastric polyps diagnosed by UGI-XR predominantly arise on the Helicobacter pylori-negative gastric mucosa with a low risk of gastric cancer in Japan. In the prospective observation, none of the UGI-XR examinees with gastric polyps developed gastric cancer for at least 3 years subsequently.

  2. New Technique for Barium Daughter Ion Identification in a Liquid Xe-136 Double Beta Decay Experiment

    International Nuclear Information System (INIS)

    Fairbank, William

    2016-01-01

    This work addresses long-standing issues of fundamental interest in elementary particle physics. The most important outcome of this work is a new limit on neutrinoless double beta decay. This is an extremely rare and long-sought-after type of radioactive decay. If discovered, it would require changes in the standard model of the elementary constituents of matter, and would prove that neutrinos and antineutrinos are the same, a revolutionary concept in particle physics. Neutrinos are major components of the matter in the universe that are so small and so weakly interacting with other matter that their masses have not yet been discovered. A discovery of neutrinoless double beta decay could help determine the neutrino masses. An important outcome of the work on this project was the Colorado State University role in operating the EXO-200 neutrinoless double beta decay experiment and in analysis of the data from this experiment. One type of double beta decay of the isotope "1"3"6Xe, the two-neutrino variety, was discovered in this work. Although the other type of double beta decay, the neutrinoless variety, was not yet discovered in this work, a world's best sensitivity of 1.9x10"2"5 year half-life was obtained. This result rules out a previous claim of a positive result in a different isotope. This work also establishes that the masses of the neutrinos are less than one millionth of that of electrons. A unique EXO-200 analysis, in which the CSU group had a leading role, has established for the first time ever in a liquid noble gas the fraction of daughter atoms from alpha and beta decay that are ionized. This result has important impact on other pending studies, including nucleon decay and barium tagging. Novel additional discoveries include multiphoton ionization of liquid xenon with UV pulsed lasers, which may find application in calibration of future noble liquid detectors, and studies of association and dissociation reactions of Ba"+ ions in gaseous xenon. Through

  3. New Technique for Barium Daughter Ion Identification in a Liquid Xe-136 Double Beta Decay Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Fairbank, William [Colorado State Univ., Fort Collins, CO (United States)

    2016-06-08

    This work addresses long-standing issues of fundamental interest in elementary particle physics. The most important outcome of this work is a new limit on neutrinoless double beta decay. This is an extremely rare and long-sought-after type of radioactive decay. If discovered, it would require changes in the standard model of the elementary constituents of matter, and would prove that neutrinos and antineutrinos are the same, a revolutionary concept in particle physics. Neutrinos are major components of the matter in the universe that are so small and so weakly interacting with other matter that their masses have not yet been discovered. A discovery of neutrinoless double beta decay could help determine the neutrino masses. An important outcome of the work on this project was the Colorado State University role in operating the EXO-200 neutrinoless double beta decay experiment and in analysis of the data from this experiment. One type of double beta decay of the isotope 136Xe, the two-neutrino variety, was discovered in this work. Although the other type of double beta decay, the neutrinoless variety, was not yet discovered in this work, a world’s best sensitivity of 1.9x1025 year half-life was obtained. This result rules out a previous claim of a positive result in a different isotope. This work also establishes that the masses of the neutrinos are less than one millionth of that of electrons. A unique EXO-200 analysis, in which the CSU group had a leading role, has established for the first time ever in a liquid noble gas the fraction of daughter atoms from alpha and beta decay that are ionized. This result has important impact on other pending studies, including nucleon decay and barium tagging. Novel additional discoveries include multiphoton ionization of liquid xenon with UV pulsed lasers, which may find application in calibration of future noble liquid detectors, and studies of association and dissociation reactions of Ba

  4. Upper Gastrointestinal (GI) Series

    Science.gov (United States)

    ... standard barium upper GI series, which uses only barium a double-contrast upper GI series, which uses both air and ... evenly coat your upper GI tract with the barium. If you are having a double-contrast study, you will swallow gas-forming crystals that ...

  5. Associated factors of atrophic gastritis diagnosed by double-contrast upper gastrointestinal barium X-ray radiography: a cross-sectional study analyzing 6,901 healthy subjects in Japan.

    Directory of Open Access Journals (Sweden)

    Nobutake Yamamichi

    Full Text Available Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP infection.We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach.Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880. These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β and odds ratio (OR demonstrated that serum HP IgG (β = 1.499, OR = 4.48, current smoking (β = 0.526, OR = 1.69, age (β = 0.401, OR = 1.49, low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40, and male gender (β = 0.306, OR = 1.36 showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (p<0.0001. Contrastively, UGI-XR-based atrophic gastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9% and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%, which are not significantly different from gastric acid suppressant-free subjects.The presence of UGI-XR-based atrophic gastritis is positively

  6. Contrast Materials

    Science.gov (United States)

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  7. Radiologic findings of double contrast knee arthrography

    International Nuclear Information System (INIS)

    Choi, Hye Ran; Ahn, Byeong Yeob; Kim, Mi Young; Lee, So Hyun; Suh, Chang Hae; Chung, Won Kyun

    1990-01-01

    The double contrast arthrography of the knee is a highly accurate diagnostic modality in wide rage of the clinical disorders of the knee. It allows radiological assessment of the menisci, the articular cartilages, the synovium and the ligaments. The double contrast knee arthrography was performed in 356 cases at Inha hospital for about 3 years from June 1986 to June 1989. Among them, 115 cases were abnormal, and were analyzed clinically and radiologically with the back ground of the operative finding. The results were as follows ; 1. Of the 115 cases, male were 77 and female 38. Male exceeds female in the ratio of 2 : 1. 2. The age group of 20 - 39 years was commonly involved (60%). 3. The right knee was more commonly involved than the left and the medial meniscus tear was more common (61%). The posterior horn of the meniscus was more frequently torn than the other parts of the meniscus (42%). 4. The incidence of the bucket-handle tear was the most frequent (33%). 5. The cases of the popliteal cyst were 16 (13.9%), and the combined meniscus tears were in 4 cases (25%). 6. The numbers of the discoid meniscus were 9 (7.8%), and all were present in the lateral meniscus, and combined tears were in 4 cases (44.4%). 7. The diagnostic accuracy of the double contrast knee arthrogram was 82.7% compared with operative finding. The false positive examination were 17.3%

  8. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  9. ORIGINAL ARTICLE ORIG ORIG Comparison of barium and ...

    African Journals Online (AJOL)

    SA JOURNAL OF RADIOLOGY • June 2007. ORIG. Abstract. Background. Simulation of patients with carcinoma of the oesophagus using radio-opaque contrast is a standard step in treatment planning prior to delivering radiation therapy. Various contrast mediums such as barium, gastrograffin and hexabrix have been used ...

  10. Choice and technique of negative contrast in double contrast roentgenography of the stomach

    International Nuclear Information System (INIS)

    Pomakov, P.; Tomov, A.; Popsavov, P.; Tirolska, M.

    1993-01-01

    A comparative study of 8 negative contrast media is performed in 720 patients undergoing double-contrast abdominal biomedical radiography. The following preparations and methods are compared: Unibarit (Roelm, Pharma), CO 2 granulate (Nicholas), Sandosten Calcium + Calcium gluconicum (Sandoz, Pharmachim), Kalinor (Nordmark), dust variation of p. Rivieri, conducted aerophagy, stomach-tube, 'Echo'-lemonade. The average size of the gas bubble of the fornix (cm 2 ), the average volume of the gas collection (ml) and the relationship between the area of the negative contrast image (cm 2 ) and the volume of the gas (ml) is given. Some possibilities for production of domestic negative contrast media are also discussed. 2 tabs., 18 refs. (orig.)

  11. Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samples

    Energy Technology Data Exchange (ETDEWEB)

    Dullin, Christian, E-mail: christian.dullin@med.uni-goettingen.de [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Monego, Simeone dal [Cluster in Biomedicine, AREA Science Park Basovizza, Trieste (Italy); Larsson, Emanuel [Elettra Sincrotrone Trieste, Strada Statale 14, km 163.5 in AREA Science Park, 34149 Basovizza (Trieste) (Italy); University of Trieste, Trieste (Italy); Linköping University, SE-581 83 Linkoeping (Sweden); Mohammadi, Sara [Elettra Sincrotrone Trieste, Strada Statale 14, km 163.5 in AREA Science Park, 34149 Basovizza (Trieste) (Italy); Krenkel, Martin [University of Göttingen, Göttingen (Germany); Garrovo, Chiara; Biffi, Stefania [IRCCS Burlo Garofolo, Trieste (Italy); Lorenzon, Andrea [Cluster in Biomedicine, AREA Science Park Basovizza, Trieste (Italy); Markus, Andrea [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Napp, Joanna [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Max Planck Institute for Experimental Medicine, Hermann-Rein-Strasse 3, 37075 Göttingen (Germany); University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Salditt, Tim [University of Göttingen, Göttingen (Germany); Accardo, Agostino [University of Trieste, Trieste (Italy); Alves, Frauke [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Max Planck Institute for Experimental Medicine, Hermann-Rein-Strasse 3, 37075 Göttingen (Germany); University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Tromba, Giuliana [Elettra Sincrotrone Trieste, Strada Statale 14, km 163.5 in AREA Science Park, 34149 Basovizza (Trieste) (Italy)

    2015-01-01

    This study presents an approach to increase the sensitivity of lung computed tomography (CT) imaging by utilizing in-line phase contrast CT in combination with single-distance phase-retrieval algorithms and a dedicated image-processing regime. As demonstrated here, functional CT imaging can be achieved for the assessment of both structural alterations in asthmatic mouse lung tissue and the accumulation pattern of instilled barium-sulfate-labelled macrophages in comparison with healthy controls. Functionalized computed tomography (CT) in combination with labelled cells is virtually non-existent due to the limited sensitivity of X-ray-absorption-based imaging, but would be highly desirable to realise cell tracking studies in entire organisms. In this study we applied in-line free propagation X-ray phase-contrast CT (XPCT) in an allergic asthma mouse model to assess structural changes as well as the biodistribution of barium-labelled macrophages in lung tissue. Alveolar macrophages that were barium-sulfate-loaded and fluorescent-labelled were instilled intratracheally into asthmatic and control mice. Mice were sacrificed after 24 h, lungs were kept in situ, inflated with air and scanned utilizing XPCT at the SYRMEP beamline (Elettra Synchrotron Light Source, Italy). Single-distance phase retrieval was used to generate data sets with ten times greater contrast-to-noise ratio than absorption-based CT (in our setup), thus allowing to depict and quantify structural hallmarks of asthmatic lungs such as reduced air volume, obstruction of airways and increased soft-tissue content. Furthermore, we found a higher concentration as well as a specific accumulation of the barium-labelled macrophages in asthmatic lung tissue. It is believe that XPCT will be beneficial in preclinical asthma research for both the assessment of therapeutic response as well as the analysis of the role of the recruitment of macrophages to inflammatory sites.

  12. Double-contrast barium enema in the diagnosis of intestinal deeply infiltrating endometriosis

    OpenAIRE

    Ribeiro, Helizabet Salomão Abdalla Ayroza; Ribeiro, Paulo Augusto Ayroza Galvão; Rodrigues, Francisco César; Donadio, Nilson; Auge, Antônio Pedro Flores; Aoki, Tsutomu

    2008-01-01

    OBJETIVO: avaliar a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do enema de bário com duplo contraste (EBDC) para o diagnóstico da endometriose do reto e sigmóide. MÉTODOS: estudo transversal prospectivo que incluiu 37 pacientes com quadro clínico suspeito de endometriose profunda. As pacientes foram submetidas ao EBDC de acordo com a técnica padrão descrita na literatura. Em seguida, foram submetidas à laparoscopia. Os exames foram realizados e seus res...

  13. Double contrast investigation of the stomach in hypotonia

    International Nuclear Information System (INIS)

    Roggensack, H.O.

    1980-01-01

    After two years experience of routine investigation of the stomach in double contrast and hypotonia the advantages of this method and its main field of application are described pertaining to selected cases. (orig.) [de

  14. Acute respiratory failure caused by aspiration of high density barium: A case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Jung, Eun A; Yang, Ik; Lee, Yul; Chung, Soo Young

    1994-01-01

    Accidental aspiration of barium contrast medium during the upper gastrointestinal study can occur in patients with swallowing disorder, especially in the elderly patients. We experienced a case of respiratory failure followed by death within a few hours in 85 year-old patient after barium aspiration

  15. Double contrast examination of the colon. Die Doppelkontrastuntersuchung des Dickdarms

    Energy Technology Data Exchange (ETDEWEB)

    Welin, S.; Welin, G.

    1980-01-01

    The double contrast method has been modified in order to get a more detailed picture of the mucous membrane of the colon. The method has been employed at Malmoe hospital since 1953. The method and its diagnostic application in cases of adenoids, villiferous tumours, diverticula, Crohn's disease, ulcerating colitis, and deformation of the rectum/sigma junction due to external endometriosis and peritoneal carcinosis are described. The diagnostic values of the double contrast method and colposcopy/biopsy of the colon are compared. The two methods are found to be complementary.

  16. BARIUM RECOVERY PROCESS

    Science.gov (United States)

    Blanco, R.E.

    1959-07-21

    A method of separating barium from nuclear fission products is described. In accordance with the invention, barium may be recovered from an acidic solution of neutron-irradiated fissionable material by carrying ihe barium cut of solution as a sulfate with lead as a carrier and then dissolving the barium-containing precipitate in an aqueous solution of an aliphatic diamine chelating reagent. The barium values together with certain other metallic values present in the diamine solution are then absorbed onto a cation exchange resin and the barium is selectively eluted from the resin bed with concentrated nitric acid.

  17. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases; Valor del enema de bario en pacientes con colonoscopia incompleta. Estudio prospectivo de 45 casos

    Energy Technology Data Exchange (ETDEWEB)

    Gispert, S.; Mayolas, N.; Hidalgo, A. [Hospital General Universitario Vall de Hebron. Barcelona (Spain)

    2003-07-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs.

  18. Associated Factors of Atrophic Gastritis Diagnosed by Double-Contrast Upper Gastrointestinal Barium X-Ray Radiography: A Cross-Sectional Study Analyzing 6,901 Healthy Subjects in Japan

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Shimamoto, Takeshi; Minatsuki, Chihiro; Takahashi, Yu; Nakayama, Chiemi; Matsuda, Rie; Fujishiro, Mitsuhiro; Konno-Shimizu, Maki; Kato, Jun; Kodashima, Shinya; Ono, Satoshi; Niimi, Keiko; Mochizuki, Satoshi; Tsuji, Yosuke; Sakaguchi, Yoshiki; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kakimoto, Hikaru; Wada, Ryoichi; Mitsushima, Toru; Ichinose, Masao; Koike, Kazuhiko

    2014-01-01

    Background Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP) infection. Methods We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach. Results Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880). These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β) and odds ratio (OR) demonstrated that serum HP IgG (β = 1.499, OR = 4.48), current smoking (β = 0.526, OR = 1.69), age (β = 0.401, OR = 1.49), low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40), and male gender (β = 0.306, OR = 1.36) showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (pgastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9%) and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%), which are not significantly different from gastric acid suppressant-free subjects. Conclusions The presence of UGI-XR-based atrophic gastritis is positively associated with

  19. Valor do enema de bário com duplo contraste no diagnóstico da endometriose do reto e sigmóide Double-contrast barium enema in the diagnosis of intestinal deeply infiltrating endometriosis

    Directory of Open Access Journals (Sweden)

    Helizabet Salomão Abdalla Ayroza Ribeiro

    2008-08-01

    Full Text Available OBJETIVO: avaliar a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do enema de bário com duplo contraste (EBDC para o diagnóstico da endometriose do reto e sigmóide. MÉTODOS: estudo transversal prospectivo que incluiu 37 pacientes com quadro clínico suspeito de endometriose profunda. As pacientes foram submetidas ao EBDC de acordo com a técnica padrão descrita na literatura. Em seguida, foram submetidas à laparoscopia. Os exames foram realizados e seus resultados e imagens foram interpretados e comparados com base na avaliação histológica. A análise estatística foi realizada pela análise de associação (teste do χ2 e análise de concordância (teste de Kappa. RESULTADOS: a média de idade das pacientes estudadas foi de 35,8±4,4 anos (faixa de 28 a 48 anos, sendo 85,6% brancas e 14,4% negras. A endometriose profunda foi confirmada por laparoscopia e pelo exame histológico em todas as pacientes estudadas. A endometriose intestinal foi confirmada histologicamente em 27 mulheres (72,9%. O EBDC demonstrou sinais radiológicos sugestivos de infiltração intestinal por endometriose em 24 mulheres (64,9% e ausência de sinais em 13 mulheres (35,1%. A sensibilidade do método foi de 87,5%, especificidade de 53,8%, valor preditivo positivo de 77,8% e valor preditivo negativo de 70%. Dentre os 24 exames anormais, 16 (43,2% apresentaram imagem radiológica do tipo espícula, 16 (43,2% apresentavam imagem compatível com estenose e quatro (10,8% o duplo contorno. CONCLUSÕES: o EBDC apresenta elevada sensibilidade e elevado valor preditivo positivo no diagnóstico da endometriose do reto e sigmóide. As imagens radiológicas do tipo espícula e estenose apresentam elevada sensibilidade e valor preditivo positivo para a infiltração intestinal por endometriose.PURPOSE: to evaluate the sensitivity, specificity, positive and negative predictive value of double contrast barium enema (DCBE for the diagnoses

  20. Clinical efficacy of a new barium sulfate for abdominal CT

    International Nuclear Information System (INIS)

    Yamada, Tatuya; Kohno, Mitio; Uematsu, Sadao; Nisitani, Hiromu; Tanaka, Takao.

    1988-01-01

    Computed Tomography of the abdomen requires that the intestines are filled with contrast medium so that the gut is not misinterpreted as a pathologic process. Besides, normal structures may be difficult to delimit in patients with scanty intra-abdominal fat. In Japan, up to date, only a single contrast medium has been available for this purpose, Gastrografin and thus identical with the intravasculaly used Urografin or Angiografin. A new Barium Sulfate suspention (Fusimi Seiyaku, Kagawa) for computed tomographic use has been dilute solution (4.77 %) and with suspending agents that prevent a rapid sedimentation of the Barium Sulfate. The aim of this investigation was to compare Gastrografin with a new barium regarding patients tolerance, side effects and diagnostic information. The investigation comprised 146 patients who were reffered for abdominal CT and was carried out by 5 facilities; National Cancer Center, Kobe University, Chiba University, Kyushu University and Juntendo University. Diagnostic information was judged with respect to the filling of the stomach and intestines, the presence of imaging artifacts and finally clinical estimation. Patients tolerance was investigated as regards taste and side effects. Good filling of the stomach and intestines was obtained in this investigation. However, imaging artifacts occured in only a few cases. The imaging artifacts appeared almost exclusively to arise in the boundary layer between the bowel gas and contrast medium, and were most common in the stomach. However, the contrasting effect of this medium did not in itself appear to cause any imaging artifacts. Fushimi's new barium seems to be preffered because of its lesser tendency to arise artifacts and better tendency to make good filling of the stomach and intestines. Moreover, this investigation did not have any side effects. (J.P.N.)

  1. Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

    Science.gov (United States)

    Alsufyani, N A; Noga, M L; Finlay, W H; Major, P W

    2013-01-01

    The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

  2. The use of low-osmolar water-soluble contrast in videofluoroscopic swallowing exams.

    Science.gov (United States)

    Harris, Julie A; Bartelt, Detlef; Campion, Molly; Gayler, Bob W; Jones, Bronwyn; Hayes, Andrea; Haynos, Judith; Herbick, Seanne; Kling, Therese; Lingaraj, Arpana; Singer, Michele; Starmer, Heather; Smith, Christine; Webster, Kim

    2013-12-01

    The selection of the contrast agent used during fluoroscopic exams is an important clinical decision. The purpose of this article is to document the usage of a nonionic, water-soluble contrast (iohexol) and barium contrast in adult patients undergoing fluoroscopic exams of the pharynx and/or esophagus and provide clinical indications for the use of each. For 1 year, data were collected on the use of iohexol and barium during fluoroscopic exams. The contrast agent used was selected by the speech language pathologist (SLP) or the radiologist based on the exam's indications. A total of 1,978 fluoroscopic exams were completed in the 12-month period of documentation. Of these exams, 60.6 % were completed for medical reasons and 39.4 % for surgical reasons. Fifty-five percent of the exams were performed jointly by a SLP and a radiologist and 45 % were performed by a radiologist alone. Aspiration was present in 22 % of the exams, vestibular penetration occurred in 38 %, extraluminal leakage of contrast was observed in 4.6 %, and both aspiration and leakage were seen in 1 % of the exams. In cases with aspiration, iohexol was used alone in 8 %, iohexol and barium were both used in 45 %, and barium was used alone in 47 %. In cases with extraluminal leakage, iohexol was used alone in 58 %, iohexol and barium were both used in 31 %, and barium was used alone in 11 %. No adverse effects were seen with the use of iohexol. When barium was used in cases of aspiration and extraluminal leakage, the amount of aspirated barium was small and the extraluminal barium in the instances of leakage was small. Iohexol is a useful screening contrast agent and can safely provide information, and its use reduces the risk of aspiration and the chance of leakage of large amounts of barium.

  3. Double contrast arthrography of the shoulder

    International Nuclear Information System (INIS)

    Gasparini, D.

    1991-01-01

    From 1980 to 1989 the author performed 481 double-contrast arthrographic examinations of the shoulder (DCSA). A hundred and forty-two complete and 46 partial rotator cuff tears were demonstrated; 68 of them underwent surgical exploration. Results confirmed DCSA capabilities in detecting both their location (100%) and size (95%). Moreover, thickness (89%) and erosions (94%) in tendon edges and surfaces were demonstrated - that is, all the qualitative information needed to depict degenerative processes. Such evidence may also affect treatment planning

  4. Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samples.

    Science.gov (United States)

    Dullin, Christian; dal Monego, Simeone; Larsson, Emanuel; Mohammadi, Sara; Krenkel, Martin; Garrovo, Chiara; Biffi, Stefania; Lorenzon, Andrea; Markus, Andrea; Napp, Joanna; Salditt, Tim; Accardo, Agostino; Alves, Frauke; Tromba, Giuliana

    2015-01-01

    Functionalized computed tomography (CT) in combination with labelled cells is virtually non-existent due to the limited sensitivity of X-ray-absorption-based imaging, but would be highly desirable to realise cell tracking studies in entire organisms. In this study we applied in-line free propagation X-ray phase-contrast CT (XPCT) in an allergic asthma mouse model to assess structural changes as well as the biodistribution of barium-labelled macrophages in lung tissue. Alveolar macrophages that were barium-sulfate-loaded and fluorescent-labelled were instilled intratracheally into asthmatic and control mice. Mice were sacrificed after 24 h, lungs were kept in situ, inflated with air and scanned utilizing XPCT at the SYRMEP beamline (Elettra Synchrotron Light Source, Italy). Single-distance phase retrieval was used to generate data sets with ten times greater contrast-to-noise ratio than absorption-based CT (in our setup), thus allowing to depict and quantify structural hallmarks of asthmatic lungs such as reduced air volume, obstruction of airways and increased soft-tissue content. Furthermore, we found a higher concentration as well as a specific accumulation of the barium-labelled macrophages in asthmatic lung tissue. It is believe that XPCT will be beneficial in preclinical asthma research for both the assessment of therapeutic response as well as the analysis of the role of the recruitment of macrophages to inflammatory sites.

  5. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    International Nuclear Information System (INIS)

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  6. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  7. Barium enema

    Science.gov (United States)

    ... series; Colorectal cancer - lower GI series; Colorectal cancer - barium enema; Crohn disease - lower GI series; Crohn disease - barium enema; Intestinal blockage - lower GI series; Intestinal blockage - ...

  8. High contrast computed tomography with synchrotron radiation

    Science.gov (United States)

    Itai, Yuji; Takeda, Tohoru; Akatsuka, Takao; Maeda, Tomokazu; Hyodo, Kazuyuki; Uchida, Akira; Yuasa, Tetsuya; Kazama, Masahiro; Wu, Jin; Ando, Masami

    1995-02-01

    This article describes a new monochromatic x-ray CT system using synchrotron radiation with applications in biomedical diagnosis which is currently under development. The system is designed to provide clear images and to detect contrast materials at low concentration for the quantitative functional evaluation of organs in correspondence with their anatomical structures. In this system, with x-ray energy changing from 30 to 52 keV, images can be obtained to detect various contrast materials (iodine, barium, and gadolinium), and K-edge energy subtraction is applied. Herein, the features of the new system designed to enhance the advantages of SR are reported. With the introduction of a double-crystal monochromator, the high-order x-ray contamination is eliminated. The newly designed CCD detector with a wide dynamic range of 60 000:1 has a spatial resolution of 200 μm. The resulting image quality, which is expected to show improved contrast and spatial resolution, is currently under investigation.

  9. Accelerating the transit time of barium sulphate suspensions in small bowel examinations

    International Nuclear Information System (INIS)

    Summers, David S.; Roger, Mark D.; Allan, Paul L.; Murchison, John T.

    2007-01-01

    Purpose: To determine whether hyperosmolar and effervescent agents proven individually to accelerate transit time in the barium small bowel examination have an additive effect when combined, surpassing that of either agent alone. Materials and methods: One hundred and forty-nine patients were randomised to four groups. Three hundred milliliters of barium sulphate alone was given to the first group. Fifteen milliliters of iodinated hyperosmolar contrast agent (Gastrografin, meglumine/sodium diatrizoate, Schering) was given in addition to barium sulphate to the second group while six packets of effervescent granules (Carbex, Ferring) were added for the third group. The final group was given a combination of both additives and barium sulphate. The time taken following ingestion for the contrast column to reach the caecum, as assessed by frequent interval fluoroscopy, was recorded. A subgroup of 32 patients were selected randomly from the four groups, 8 from each and assessed for quality of examination. Statistical assessments were made using Kruskal-Wallis and Mann-Whitney tests. Results: One hundred and nineteen patients were analysed after exclusions. The addition of accelerant to barium sulphate, both individually and in combination significantly reduced the small bowel transit time (p < 0.001). No significant difference existed between the additives when used with barium alone. The combined group had significantly faster transit times compared to the hyperosmolar group (p = 0.02). Differences between combined and effervescent groups tended towards significance (p = 0.09). No significant difference existed between groups when examination quality was assessed. Conclusion: These results suggest that the addition of combined effervescent and hyperosmolar agents to the barium suspension may significantly shorten the small bowel transit time without adversely affecting examination quality. This has implications for patient acceptability of the examination as well as

  10. Synthesis of barium mercaptides and application of antimony/barium mercaptides

    Institute of Scientific and Technical Information of China (English)

    瞿龙; 张露露; 舒万艮

    2001-01-01

    Mercaptoacetic acid, isooctyl thioglycolate and barium hydroxide used as start materials, barium bis (2-ethylhexyl thioglycolate) (Ba(2EHTG)2), barium thioglycolate (Ba(TG)) and barium bisthioglycolate (Ba(TG)2) were synthesized. Their optimum synthetic techniques were discussed, and some physicochemical data were reported. Infrared spectroscopy and elemental analysis methods were used to identify the structures. They were put into PVC plastic products together with antimony tris (2-ethylhexyl thioglycolate) (Sb(2EHTG)3) under the suitable compounding, and their heat stability to PVC was studied. It is shown that these barium mercaptides have remarkable synergisms with antimony mercaptides and the long-term stabilizing effect of organoantimony stabilizer can be effectively improved, reducing the amount of antimony compounds so as to avoid the decrease of its stabilizing effect.

  11. An evaluation of a radiographer-led barium enema service in the diagnosis of colorectal cancer

    International Nuclear Information System (INIS)

    Law, R.L.; Slack, N.F.; Harvey, R.F.

    2008-01-01

    Purpose: This study was undertaken to assess the sensitivity and efficacy of a radiographer-led double contrast barium enema (DCBE) service in the diagnosis of colorectal cancer (CRC). Methods: All patients on the CRC database from its inception in 1997 until the end of 2004 were cross-referenced with the radiology database. Details were recorded of any patient who had undergone a DCBE examination at any time prior to histological confirmation of colorectal cancer. All the DCBE in this review were performed and reported by radiographers as part of a protocol of double reporting with a consultant radiologist. The radiographers and radiologists reports were reviewed for each patient. Notes and X-rays were also reviewed when necessary. Reporting sensitivity was compared with the Royal College of Radiologists (RCR) barium enema examination targets for the diagnosis of colorectal carcinoma. Results: 362 of the 1005 patients on the CRC database had undergone a DCBE. Combined radiographer and radiologist reporting demonstrated a diagnostic sensitivity of 98% for CRC and were cancer specific in 93% of cases. These results compared favourably with the referenced RCR sensitivity targets for colorectal cancer. Reporting discord only occurred with the terminology of reporting 13 equivocal polyps. None of these polyps were neoplastic and thus did not affect CRC sensitivity. Conclusion: Radiographer reporting compares favourably with published CRC sensitivity data of more expensive techniques such as CT colonography. A protocol of radiographer/radiographer double reporting is now used at this hospital with radiological second opinion being acquired for more complex abnormal DCBE examination appearances. This service is a safe, cost-effective option that should not be overlooked with the increasing demand for CRC screening

  12. Double contrast MR imaging with iron colloid and Gd-DTPA in cholangiocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Suto, Y. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan); Shimatani, Y. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan); Kato, T. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan); Kamba, M. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan); Ohuchi, Y. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan); Kodama, F. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan); Kato, T.; Ohta, Y. [Dept. of Radiology, Tottori Univ. School of Medicine, Yonago (Japan)

    1994-11-01

    Double contrast MR imaging with combined use of chondroitin sulfate iron colloid (CSIC) and Gd-DTPA was attempted in 3 cases of cholangiocellular carcinoma (CCC). In all cases, nonenhanced spin echo T1- and T2-weighted images, and T1-weighted images after i.v. injection of Gd-DTPA were obtained. Within one week, the MR sequences were repeated one hour after i.v. injection of CSIC. Double contrast (CSIC/Gd-DTPA) T1-weighted imaging was evaluated and compared with the other sequences in terms of tumor detectability, tumor spreading and tumor characterization. Double contrast MR imaging was comparable in tumor detectability and superior as to the evaluation of spreading and characterization to the other MR imaging modalities. (orig.).

  13. Effectiveness of therapeutic barium enema for diverticular hemorrhage.

    Science.gov (United States)

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-05-14

    To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient's position was changed every 20 min for 3 h. Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy.

  14. Sulphate removal from sodium sulphate-rich brine and recovery of barium as a barium salt mixture.

    Science.gov (United States)

    Vadapalli, Viswanath R K; Zvimba, John N; Mulopo, Jean; Motaung, Solly

    2013-01-01

    Sulphate removal from sodium sulphate-rich brine using barium hydroxide and recovery of the barium salts has been investigated. The sodium sulphate-rich brine treated with different dosages of barium hydroxide to precipitate barium sulphate showed sulphate removal from 13.5 g/L to less than 400 mg/L over 60 min using a barium to sulphate molar ratio of 1.1. The thermal conversion of precipitated barium sulphate to barium sulphide achieved a conversion yield of 85% using coal as both a reducing agent and an energy source. The recovery of a pure mixture of barium salts from barium sulphide, which involved dissolution of barium sulphide and reaction with ammonium hydroxide resulted in recovery of a mixture of barium carbonate (62%) and barium hydroxide (38%), which is a critical input raw material for barium salts based acid mine drainage (AMD) desalination technologies. Under alkaline conditions of this barium salt mixture recovery process, ammonia gas is given off, while hydrogen sulfide is retained in solution as bisulfide species, and this provides basis for ammonium hydroxide separation and recovery for reuse, with hydrogen sulfide also recoverable for further industrial applications such as sulfur production by subsequent stripping.

  15. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough.

    Science.gov (United States)

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    To assess the routine use of barium swallow study in patients with chronic cough. Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons. The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6%) of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6%) of the patients, whereas the treatment was ineffective in 1 (8.4%). We observed no complications related to barium swallow, such as contrast aspiration. Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  16. Isotopic exchange reaction between barium ion and tri barium phosphate

    International Nuclear Information System (INIS)

    Bilgin, G.B.; Cetin, I.

    1982-01-01

    Heterogeneous exchange reaction of tri barium phosphate in barium chloride solution has been studied using 133 Ba as a tracer. The results show that the exchange fraction increases as barium chloride concentration increases for different mole ratio of the exchange ion on the solid surface and in the solution. The phenomenon was studied with respect to the previous treatment of the precipitate leading to different crystal sizes and the effect of reaction time. (author)

  17. On barium oxide solubility in barium-containing chloride melts

    International Nuclear Information System (INIS)

    Nikolaeva, Elena V.; Zakiryanova, Irina D.; Bovet, Andrey L.; Korzun, Iraida V.

    2016-01-01

    Oxide solubility in chloride melts depends on temperature and composition of molten solvent. The solubility of barium oxide in the solvents with barium chloride content is essentially higher than that in molten alkali chlorides. Spectral data demonstrate the existence of oxychloride ionic groupings in such melts. This work presents the results of the BaO solubility in two molten BaCl 2 -NaCl systems with different barium chloride content. The received data together with earlier published results revealed the main regularities of BaO solubility in molten BaO-BaCl 2 -MCl systems.

  18. Patient dose variation investigated in four Irish hospitals for barium meal and barium enema examinations

    International Nuclear Information System (INIS)

    Carroll, E.; Brennan, P.C.

    2001-01-01

    Four hospitals have been studied, intra- and inter-hospital variations examined and the mean DAP values recorded for barium enemas and barium meals. Mean DAP values for barium meals and barium enemas at 11.4 Gy.cm 2 and 20.1 Gy.cm 2 respectively have been shown. Differences between individual examinations for barium meals varied by up to a factor of 185 and for barium enemas, up to a factor of 19, with hospital means for barium meal and enema examinations each differing by up to a factor of 3. The data provided by this study have suggested that large variations in patient dose do exist in Ireland for barium meal and barium enema examinations. Fluoroscopy time was shown to be a major contributor to the variations reported, with number of images playing a minor role. Results have demonstrated the need for standardisation of technique throughout the country for these examinations. (author)

  19. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    Directory of Open Access Journals (Sweden)

    Carlos Shuler Nin

    2013-12-01

    Full Text Available OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons.RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6% of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6% of the patients, whereas the treatment was ineffective in 1 (8.4%. We observed no complications related to barium swallow, such as contrast aspiration.CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  20. Effectiveness of therapeutic barium enema for diverticular hemorrhage

    Science.gov (United States)

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-01-01

    AIM: To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. METHODS: We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient’s position was changed every 20 min for 3 h. RESULTS: Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). CONCLUSION: Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy. PMID:25987779

  1. Intolerance reaction after application of glucagon during double contrast studies

    International Nuclear Information System (INIS)

    Kainberger, F.; Fruehwald, F.; Schwaighofer, B.; Lindemayr, H.

    1986-01-01

    Whereas intolerance reactions against contrast media are a well-known hazard during radiologic procedures, intolerance reactions to other preparations used in radiology are rare. Glucagon, frequently used to induce gastrointestinal hypotonia, is said to have almost no side-effects. A case of anaphylactic reaction during double-contrast upper gastrointestinal examination is reported. Pseudoallergic reaction to propylparaben, a preservative agent in glucagon, is suspected. IgE-antibodies to glucagon could not be detected by RAST. (orig.) [de

  2. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Lithium in the barium stars

    International Nuclear Information System (INIS)

    Pinsonneault, M.H.; Sneden, C.

    1984-01-01

    New high-resolution spectra of the lithium resonance doublet have provided lithium abundances or upper limits for 26 classical and mild barium stars. The lithium lines always are present in the classical barium stars. Lithium abundances in these stars obey a trend with stellar masses consistent with that previously derived for ordinary K giants. This supports the notion that classical barium stars are post-core-He-flash or core-He-burning stars. Lithium contents in the mild barium stars, however, often are much smaller than those of the classical barium stars sometimes only upper limits may be determined. The cause for this difference is not easily understood, but may be related to more extensive mass loss by the mild barium stars. 45 references

  4. Improve identification of details in double-contrast examination of the stomach by means of a new contrast medium mixture

    International Nuclear Information System (INIS)

    Tenner, R.

    1984-01-01

    In a contrast medium study, 100 patients were employed for a comparison between the contrast medium Mikropaque liquid and a mixture of Mikropaque HD and Mikropaque liquid in double-contrast examination of the stomach. The special feature of this method was that one and the same stomach was examined in each case with both contrast media. The new contrast media mixture with Mikropaque HD represents a step forward; the contrast could be enhanced in 80% of the cases, and the finely contoured relief became visible in two-thirds of the cases, compared with one-third of the examined patients before this method was introduced. (orig.) [de

  5. Evaluation of contrast media for bronchography

    International Nuclear Information System (INIS)

    Thompson, I.M.; Whittlesey, G.C.; Slovis, T.L.; Chang, C.H.; Cullen, M.L.; Philippart, A.I.; Stockmann, P.S.; Adkins, E.S.; Klein, M.D.

    1997-01-01

    Background. Bronchography is occasionally needed for the evaluation and management of some congenital pulmonary anomalies as well as some acquired diseases, usually of the tracheo- bronchial tree. There is currently no effective, approved contrast agent for this imaging tech- nique. Objective. We evaluated five agents (barium sulfate, iohexol, propyliodone oily, propyliodone aqueous, and perflubron) in terms of image quality, histologic changes, and effects on hemodynamics, blood gases, and standard laboratory tests in New Zealand White rabbits. Materials and methods. Animals were anesthetized and intubated. Each contrast agent (0.25 ml/kg) was administered intratracheally. Three animals in each group had intravenous lines placed for blood sampling and blood pressure monitoring and were sacrificed at 1 h. An additional three animals for each agent were sacrificed at 24 h and 1 week after imaging. Blood samples were taken immediately before contrast instillation and at 1 h postbronchography. Fluoroscopic images were recorded on standard VHS video tape and evaluated in blind fashion. Segments of lung tissue and bronchi were obtained for histologic examination. Results. Necrosis and/or inflammatory infiltrates were noted in 78 % of the bronchograms performed with propyliodone aqueous, 67 % with propyliodone oily, 55 % with perflubron, and 33 % with iohexol 120, 240 and 350. No histologic damage was observed with barium. The propyliodones gave the best-quality imaging results and the most histologic changes. Iohexol, in any concentration, gave the least acceptable images and a moderate number of histologic changes. Barium sulfate demonstrated acceptable images with virtually no histologic changes. Conclusion. From the histologic and imaging results, barium is the best available contrast material for bronchography. (orig.). With 6 figs., 4 tabs

  6. Barium light source method and apparatus

    Science.gov (United States)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  7. Barium granuloma of the rectum: case report

    International Nuclear Information System (INIS)

    Kim, Dae Jin; Kim, Se Hyung; Jeoung, Ah Young; Lee, Kyoung Ho; Choi, Byung Ihn; Han, Joon Koo

    2003-01-01

    Barium granulomas usually occur after barium enema within 8 cm of the anal verge probably due to minute laceration of rectal wall by enema tip and extravasation of barium during barium enema. We report a case of barium granuloma of rectum in a 47-year-old man, who did not have history of barium enema. In rare instance, barium granuloma can occur without a history of barium enema and careful interpretation of radiologic image is essential to make a correct diagnosis

  8. A study of contrast media on X-rays of upper GI examinations

    International Nuclear Information System (INIS)

    Beck, A.; Rupp, H.G.; Reinhold, W.D.; Grosser, G.

    1989-01-01

    700 gastro intestinal x-ray pictures were controlled by four independent radiologists. Three different baryum applications in patients examination were performed. The three baryum contrast-medium were Top-Contral, Mikropaque, (H-D Barium) and Titanate de Baryum. The examination technique in all patients was the same. In different sessions every radiologist was asked for his opinion about the regularity and thickness of the emulsion of contrast-medium, of the graph of the Areae gastricae, the sharpness of the stomach-contour and the production of bubbles. Finally to every picture it had to be done a qualification concerning to its presentation from 'insignificant' to 'excellent' in four degrees. The results: Excellent pictures could be done in the Esophagus with Titanate de Baryum. Best presentation of the stomach specially in double contrast could be done with Mikropaque, a quiet similar result was the examination with Top-Contral. There is no significant differentiation between contrasts-media in the small intestine. (orig.) [de

  9. Barium toxicosis in a dog.

    Science.gov (United States)

    Adam, Fiona H; Noble, Peter J M; Swift, Simon T; Higgins, Brent M; Sieniawska, Christine E

    2010-09-01

    A 2-year-old 14.9-kg (32.8-lb) neutered female Shetland Sheepdog was admitted to the University of Liverpool Small Animal Teaching Hospital for evaluation of acute collapse. At admission, the dog was tachypneic and had reduced limb reflexes and muscle tone in all limbs consistent with diffuse lower motor neuron dysfunction. The dog was severely hypokalemic (1.7 mEq/L; reference range, 3.5 to 5.8 mEq/L). Clinical status of the dog deteriorated; there was muscle twitching, flaccid paralysis, and respiratory failure, which was considered a result of respiratory muscle weakness. Ventricular arrhythmias and severe acidemia (pH, 7.18; reference range, 7.35 to 7.45) developed. Intoxication was suspected, and plasma and urine samples submitted for barium analysis had barium concentrations comparable with those reported in humans with barium toxicosis. Analysis of barium concentrations in 5 control dogs supported the diagnosis of barium toxicosis in the dog. Fluids and potassium supplementation were administered IV. The dog recovered rapidly. Electrolyte concentrations measured after recovery were consistently unremarkable. Quantification of plasma barium concentration 56 days after the presumed episode of intoxication revealed a large decrease; however, the plasma barium concentration remained elevated, compared with that in control dogs. To our knowledge, this case represented the first description of barium toxicosis in the veterinary literature. Barium toxicosis can cause life-threatening hypokalemia; however, prompt supportive treatment can yield excellent outcomes. Barium toxicosis is a rare but important differential diagnosis in animals with hypokalemia and appropriate clinical signs.

  10. Modeling and minimization of barium sulfate scale

    Science.gov (United States)

    Alan W. Rudie; Peter W. Hart

    2006-01-01

    The majority of the barium present in the pulping process exits the digester as barium carbonate. Barium carbonate dissolves in the bleach plant when the pH drops below 7 and, if barium and sulfate concentrations are too high, begins to precipitate as barium sulfate. Barium is difficult to control because a mill cannot avoid this carbonate-to-sulfate transition using...

  11. Observation of a barium xenon exciplex within a large argon cluster.

    Science.gov (United States)

    Briant, M; Gaveau, M-A; Mestdagh, J-M

    2010-07-21

    Spectroscopic measurements provide fluorescence and excitation spectra of a single barium atom codeposited with xenon atoms on argon clusters of average size approximately 2000. The spectra are studied as a function of the number of xenon atoms per cluster. The excitation spectrum with approximately 10 xenon atoms per cluster is qualitatively similar to that observed when no xenon atom is present on the cluster. It consists of two bands located on each side of the 6s6p (1)P-6s(2) (1)S resonance line of the free barium. In contrast, the fluorescence spectrum differs qualitatively since a barium-xenon exciplex is observed, which has no counterpart in xenon free clusters. In particular an emission is observed, which is redshifted by 729 cm(-1) with respect to the Ba(6s6p (1)P-6s(2) (1)S) resonance line.

  12. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    Science.gov (United States)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  13. [Progress in the early diagnosis of cancer of the colon and rectum].

    Science.gov (United States)

    Canessa, N; Roset, J; Boffi, A; Ferrara, J B; Galano, A; Albertengo, J C

    1978-09-01

    Our experience with the air contrast examination in the cancer of colon and rectum diagnoses is showed. The colaboration among radiologist, endoscopist, pathologist and surgeon is important. In the large bowel tumors diagnosis, the radiologic and endoscopic prodedures should be evaluated together. The double colonic contrast has showed in our experience, better results than with the barium enema. Over 31 patients with both studies, we obtained 13 false negatives (with barium enema, doing then the double colonic contrast became positive 12 (92.4%).

  14. Barium Depletion in Hollow Cathode Emitters

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  15. An experimental study on tissue reaction of various contrast agents on mediastinum

    International Nuclear Information System (INIS)

    Chung, Jin Wook; Kim, Hyung Jin; Kim, Seung Hyup; Park, Jae Hyung; Chang, Kee Hyun

    1989-01-01

    Till now, there is no consensus about appropriate contrast agents for use in clinical investigation in suspected perforation of the esophagus. Gastrografin, most widely used water soluble contrast agent, is less sensitive in detection of fistulous tract and can induce pulmonary edema, leading to death occasionally, if aspirated. Barium sulphate has been contraindicated without actual evaluation of its effect on mediastinum by experimental and clinical study. The purpose of this experimental study is to evaluate the type of tissue reaction and its severity in mediastinum and, as a result, to propose appropriate contrast agents in various clinical situations of suspected esophageal leakage. Barium sulphate, Hytrat, Gastrografin, Telebrix, Hexabrix, Amipaque, Niopam, and Ultravist were injected into mediastinum of 20 rats in each. The tissue reaction of injection sites were examined microscopically and graded according severity of inflammatory reaction with serial follow up from 1 day to 8 weeks after injection. The results are as follows, 1. Barium sulphate and Hytrast produced highly significant (p<0.01) tissue reaction compared to saline group and early inflammatory reaction was more severe in Hytrast. 2. Water soluble agents produced no significant reaction in mediastinum compared to saline control group and proved to be safe in the situation of leakage into mediastinum. 3. Injected barium caused no death during 8 week follow up in spite of large injected amount and histologically produced localized indolent granuloma after 4 weeks which is expected not to cause any delayed complications. In consideration of above results, superior physical characteristics of barium sulphate and drawbacks of Gastrografin, we concluded as follows. 1. For postoperative assessment of esophageal anastomosis, Barium sulphate is the contrast agent of choice

  16. A double layer review

    International Nuclear Information System (INIS)

    Block, L.P.

    1977-06-01

    A review of the main results on electrostatic double layers (sometimes called space charge layers or sheaths) obtained from theory, and laboratory and space experiments up to the spring of 1977 is given. By means of barium jets and satellite probes, double layers have now been found at the altitudes, earlier predicted theoretically. The general potential distribution above the auroral zone, suggested by inverted V-events and electric field reversals, is corroborated. (author)

  17. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  18. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs; Estudio comparativo entre la neumocistografia, la cistografia de contraste positivo y la cistografia de doble contraste en perros

    Energy Technology Data Exchange (ETDEWEB)

    Thibaut, J.; Parada, E. [Universidad Austral de Chile, Valdivia (Chile); Vargas, L.; Deppe, R.; Born, R.

    1997-07-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [Spanish] Se tomaron 3 series de 24 radiografias cada una, en proyeccion lateral y ventrodorsal. Se trabajo en cada serie con 6 perros machos clinicamente sanos 5 con un peso que vario entre los 7 y 16 kg. Previo a cada serie se efectuo

  19. Barium and iron abundances in red giants

    International Nuclear Information System (INIS)

    Fernandez-Villacanas, J.L.; Rego, M.; Cornide, M.

    1990-01-01

    An intermediate-dispersion abundance analysis has been carried out on a sample of 21 barium and 14 comparison stars. The excess of barium over iron has been used as the most representative indicator of peculiarity. These excesses are higher in the peculiar stars than in the nonpeculiar stars. Particularly interesting is the case of HD 67447, included in the comparison stars, with an excess Ba/Fe abundance = 1.61, probably a new barium star. A trend indicating a possible anticorrelation between barium overabundance and metallicity favors the suggestion that the barium strong group is older than the barium weak one. 36 refs

  20. Double contrast study of the operated stomach in lateroposition

    International Nuclear Information System (INIS)

    Volodina, G.I.; Novakovskij, A.R.

    1986-01-01

    Anastomosis was diagnosed in 34 patients, anastomosis ulcer in 3, cancer of the stump in 2, recurrence of stomach polyposis in 1 and cicatrical structure of the jejunum in 1. The great potentialities of a double contrast study of the operated stomach in lateroposition in the differential diagnosis of cancer of the stomach stump, deformities and other diseases were noted. The above method of examination of the operated stomach was recommended as an adjuvant to the commonly used method

  1. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  2. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  3. Radioactive Barium Ion Trap Based on Metal-Organic Framework for Efficient and Irreversible Removal of Barium from Nuclear Wastewater.

    Science.gov (United States)

    Peng, Yaguang; Huang, Hongliang; Liu, Dahuan; Zhong, Chongli

    2016-04-06

    Highly efficient and irreversible capture of radioactive barium from aqueous media remains a serious task for nuclear waste disposal and environmental protection. To address this task, here we propose a concept of barium ion trap based on metal-organic framework (MOF) with a strong barium-chelating group (sulfate and sulfonic acid group) in the pore structures of MOFs. The functionalized MOF-based ion traps can remove >90% of the barium within the first 5 min, and the removal efficiency reaches 99% after equilibrium. Remarkably, the sulfate-group-functionalized ion trap demonstrates a high barium uptake capacity of 131.1 mg g(-1), which surpasses most of the reported sorbents and can selectively capture barium from nuclear wastewater, whereas the sulfonic-acid-group-functionalized ion trap exhibits ultrafast kinetics with a kinetic rate constant k2 of 27.77 g mg(-1) min(-1), which is 1-3 orders of magnitude higher than existing sorbents. Both of the two MOF-based ion traps can capture barium irreversibly. Our work proposes a new strategy to design barium adsorbent materials and provides a new perspective for removing radioactive barium and other radionuclides from nuclear wastewater for environment remediation. Besides, the concrete mechanisms of barium-sorbent interactions are also demonstrated in this contribution.

  4. Radiologic and histopathologic evaluation of various contrast media for bronchography

    International Nuclear Information System (INIS)

    Kang, Eun Young; Hong, Ki Taek; Kim, Jin Hyung; Kim, Hyung Rae; Shin, Bong Kyung; Oh, Yu Whan; Kim, Han Kyeom; Park, Cheol Min; Seol, Hae Young; Cha, In Ho

    1999-01-01

    To determine which contrast media are both efficient and safe for the imaging of airways. We evaluated five contrast media (barium, gastrografin, iotrolan, ioxaglate, iopentol) in terms of image quality and their effects on the lungs of 25 white rabbits. For bronchography 0.5ml of contrast media was used. In each contrast group, HRCT scans were obtained immediately (n=5), 12 hours (n=4), 1 day (n=3), 2 days (n=2), and 1 week (n=1) after bronchography. Histopathologic specimens were obtained immediately, 12 hours, 1 day, 2 days, and 1 week later. Bronchograms were evaluated for image quality by three radiologists working independently, and were scored as 1(poor), 2(moderate), or 3(good) in terms of contrast quality and bronchial coating. HRCT was evaluated by two radiologists who reached a concensus;they determined the presence of contrast media, and then the pattern and extent of pulmonary opacity, and any related changes. Histopatholgic specimens were evaluated by two pathologists who sought consensus as to the extent of inflammation, pulmonary edema, and hemorrhage, and any changes in these aspects. Bronchography indicated that the sum of scores for contrast quality was 45 for barium, 33 for gastrografin, 28 for iotrolan, 30 for ioxaglate, and 28 for iopentol, while for each of these media, the sum of scores for bronchial coating was 39, 19, 25, 23, and 21, respectively. Barium showed the best image quality. In all rabbits, HRCT demonstrated the variable extent of ground-glass attenuation and/or consolidation. Lesions were most extensive at 1-2days and then regressed at 1 week;these HRCT findings correlated well with histologic findings. In histologic studies of all five contrast media groups, variable severe inflammatory reactions were observed, with or without necrosis, congesion, edema, and hemorrhage. It was noted that ioxaglate appeared to cause least tissue reaction. The imaging results of this experimental study indicate that for bronchography, barium is

  5. Barium inhibits arsenic-mediated apoptotic cell death in human squamous cell carcinoma cells.

    Science.gov (United States)

    Yajima, Ichiro; Uemura, Noriyuki; Nizam, Saika; Khalequzzaman, Md; Thang, Nguyen D; Kumasaka, Mayuko Y; Akhand, Anwarul A; Shekhar, Hossain U; Nakajima, Tamie; Kato, Masashi

    2012-06-01

    Our fieldwork showed more than 1 μM (145.1 μg/L) barium in about 3 μM (210.7 μg/L) arsenic-polluted drinking well water (n = 72) in cancer-prone areas in Bangladesh, while the mean concentrations of nine other elements in the water were less than 3 μg/L. The types of cancer include squamous cell carcinomas (SCC). We hypothesized that barium modulates arsenic-mediated biological effects, and we examined the effect of barium (1 μM) on arsenic (3 μM)-mediated apoptotic cell death of human HSC-5 and A431 SCC cells in vitro. Arsenic promoted SCC apoptosis with increased reactive oxygen species (ROS) production and JNK1/2 and caspase-3 activation (apoptotic pathway). In contrast, arsenic also inhibited SCC apoptosis with increased NF-κB activity and X-linked inhibitor of apoptosis protein (XIAP) expression level and decreased JNK activity (antiapoptotic pathway). These results suggest that arsenic bidirectionally promotes apoptotic and antiapoptotic pathways in SCC cells. Interestingly, barium in the presence of arsenic increased NF-κB activity and XIAP expression and decreased JNK activity without affecting ROS production, resulting in the inhibition of the arsenic-mediated apoptotic pathway. Since the anticancer effect of arsenic is mainly dependent on cancer apoptosis, barium-mediated inhibition of arsenic-induced apoptosis may promote progression of SCC in patients in Bangladesh who keep drinking barium and arsenic-polluted water after the development of cancer. Thus, we newly showed that barium in the presence of arsenic might inhibit arsenic-mediated cancer apoptosis with the modulation of the balance between arsenic-mediated promotive and suppressive apoptotic pathways.

  6. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, J.P. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Duarte, G.W. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Research Group in Technology and Information, Centro Universitário Barriga Verde (UNIBAVE), Santa Catarina, SC (Brazil); Caldart, C. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Kniess, C.T. [Post-Graduate Program in Professional Master in Management, Universidade Nove de Julho, São Paulo, SP (Brazil); Montedo, O.R.K.; Rocha, M.R. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Riella, H.G. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Fiori, M.A., E-mail: fiori@unochapeco.edu.br [Post-Graduate Program in Environmental Science, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil); Post-Graduate Program in Technology and Management of the Innovation, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil)

    2015-11-15

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound.

  7. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    International Nuclear Information System (INIS)

    Fernandes, J.P.; Duarte, G.W.; Caldart, C.; Kniess, C.T.; Montedo, O.R.K.; Rocha, M.R.; Riella, H.G.; Fiori, M.A.

    2015-01-01

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound

  8. Magnesium sulfate as an oral contrast medium in magnetic resonance imaging of the small intestine.

    Science.gov (United States)

    Shi, Hao; Liu, Cun; Ding, Hong Yu; Li, Chun Wei

    2012-03-01

    To explore the use of magnesium sulfate (MgSO4) as an oral contrast medium (CM) in MRI of the small intestine. By comparing MgSO4 SNRs at different concentrations, we determined that 2.5% MgSO4 is the ideal concentration for small bowel MRI. Twenty volunteers underwent MRI after drinking 2.5% MgSO4. Thirty-one patients with clinical suspicion of small intestinal pathology underwent both MRI and the air-barium contrast examination. The patient's tolerance, side effects and complications were noted. 2.5% MgSO4 can decrease the absorption of water and fully fill the enteric cavity, thereby increasing the contrast between the intestinal wall and lumen and facilitating radiographic examination of the small bowel. The mean diameter of the small intestine was 19.8±1.21 mm in the 20 volunteers consuming 2.5% MgSO4 and 12.7±0.84 mm in the 20 volunteers given water. There was a significant difference (P0.05) in side effects between MgSO4 and water groups. Small intestinal MRI was successfully performed in all 31 patients, who were also examined by the double contrast barium, which gave almost identical diagnoses to MRI in all cases except for 1 patient with small intestinal hemorrhage. MRI with 2.5% MgSO4 can demonstrate intestinal abnormalities. Therefore, 2.5% MgSO4 solution is an ideal oral CM for small bowel MRI. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  10. Barium aspiration and alveolarisation of barium in an infant: A case report and review of management

    Directory of Open Access Journals (Sweden)

    Alan F. Isles

    2014-05-01

    Full Text Available We describe a case of bilateral inhalation and alveolarisation of barium in an infant following a barium swallow for investigation of dusky spells associated with feeds. A bronchoscopy subsequently revealed the presence of a mid-tracheal tracheo-oesophageal cleft. We review the literature on barium aspiration, its consequences and make recommendations for management.

  11. CBED contrast in the lower order Laue zone

    International Nuclear Information System (INIS)

    Rossouw, C.J.; Maunders, C.J.; Whitfield, H.J.; Etheridge, J.

    2006-01-01

    Contrast in a systematic arrangement of lower order Laue zone (LOLZ) beams is reported and analysed using a Bloch wave description. Observations are reported for hexagonal barium ruthenium zirconate (Ba 4 Ru 3 ZrO 12 ) and barium ruthenium titanate (Ba 3 Ti 2 RuO 9 ), both near the c -axis orientation. The specific scattering dynamics invoked by this diffraction geometry may have novel uses in the exploration of crystallographic parameters

  12. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  13. Radiographic, Hematologic and Biochemical Alterations in Peritoneal Fluid after Intraperitoneal Injection of Barium Sulfate and Gastrografin in Rabbit

    Directory of Open Access Journals (Sweden)

    Sardar Jafari-Shoorijeh

    2012-07-01

    Full Text Available Background: Evaluation of contrast-induced changes in the peritoneal area may reveal the effects of their permeation followed by gastrointestinal perforation. This study aims to compare the radiographic changes and hematological and biochemical parameters of peritoneal fluid and blood after intraperitoneal injection of barium sulfate and gastrografin to the rabbit.Materials and Methods: In this clinical trial, 15 healthy male rabbits were randomly divided into 3 groups. Respectively to each group 10 ml/kg barium sulfate 30%, 10 ml/kg gastrografin, and 10 ml/kg saline was intraperitoneally injected. Before injection and 24 hours after injection, blood samples and peritoneal fluid were collected to measure glucose, total protein, WBC count and pH. Lateral and dorsal-ventral radiography was provided 20 min and 24 hours after contrast injection.Results: After injection of barium sulfate, serum glucose decreased, cell count and blood neutrophil percentage increased, glucose and the percentage of peritoneal fluid lymphocytes decreased (p<0.05. The amount of total protein, cell count and peritoneal fluid neutrophil percentage increased (p<0.05. Gastrografin injection only increased peritoneal fluid total protein (p=0.04. Other blood factors and peritoneal fluid showed no significant changes. In radiographies, barium sulfate remained in abdominal area and rapid absorption of gastrografin was observed.Conclusion: The use of gastrografin has fewer side effects than barium sulfate and is recommended in patients suspected with gastrointestinal perforation.

  14. Statistical properties of barium stars

    International Nuclear Information System (INIS)

    Hakkila, J.E.

    1986-01-01

    Barium stars are G- and K-giant stars with atmospheric excesses of s-process elements, and a broadband spectral depression in the blue portion of the spectrum. The strength of the λ4554 Ball line is used as a classification parameter known as the Barium Intensity. They have a mean absolute magnitude of 1.0 and a dispersion of 1.2 magnitudes (assuming a Gaussian distribution in absolute magnitude) as measured from secular and statistical parallaxes. These stars apparently belong to a young-disk population from analyses of both the solar reflex motion and their residual velocity distribution, which implies that they have an upper mass limit of around three solar masses. There is no apparent correlation of barium intensity with either luminosity or kinematic properties. The barium stars appear to be preferentially distributed in the direction of the local spiral arm, but show no preference to associate with or avoid the direction of the galactic center. They do not appear related to either the carbon or S-stars because of these tendencies and because of the stellar population to which each type of star belongs. The distribution in absolute magnitude combined with star count analyses implies that these stars are slightly less numerous than previously believed. Barium stars show infrared excesses that correlate with their barium intensities

  15. Tunable Resonant-Cavity-Enhanced Photodetector with Double High-Index-Contrast Grating Mirrors

    DEFF Research Database (Denmark)

    Learkthanakhachon, Supannee; Yvind, Kresten; Chung, Il-Sug

    2013-01-01

    In this paper, we propose a broadband-tunable resonant-cavity-enhanced photodetector (RCE-PD) structure with double high-index-contrast grating (HCG) mirrors and numerically investigate its characteristics. The detector is designed to operate at 1550-nm wavelength. The detector structure consists....... Furthermore, the fact that it can be fabricated on a silicon platform offers us a possibility of integration with electronics.......In this paper, we propose a broadband-tunable resonant-cavity-enhanced photodetector (RCE-PD) structure with double high-index-contrast grating (HCG) mirrors and numerically investigate its characteristics. The detector is designed to operate at 1550-nm wavelength. The detector structure consists...... of a top InP HCG mirror, a p-i-n photodiode embedding multiple quantum wells, and a Si HCG mirror formed in the Si layer of a silicon-on-insulator wafer. The detection wavelength can be changed by moving the top InP HCG mirror suspended in the air. High reflectivity and small penetration length of HCGs...

  16. Simultaneous double-contrast cystography and cystometry in dogs

    International Nuclear Information System (INIS)

    Mahaffey, M.B.; Barber, D.L.; Barsanti, J.A.; Crowell, W.A.

    1984-01-01

    Double-contrast cystograms and cystometrograms were performed simultaneously in each of six male and six female dogs with normal urinalyses. The dogs were sedated with oxymorphone and acepromazine. Detrusor reflex occurred in 11 of 12 dogs. After bladder infusion of 0.88 ml/kg of positive-contrast medium, there was mucosal irregularity in eight of 12 dogs and bladder shape distortion in 12 of 12 dogs. Bladder distortion decreased with progressive infusion of CO 2 , and mucosal irregularity was eliminated after infusion of 50–100 ml CO 2 . The bladder neck in all dogs was initially located within the pelvic canal. In ten of 12 dogs, the bladder neck was cranially displaced when the bladder was fully distended. Bladder wall thickness was approximately 1 mm circumferentially at all degrees of distention. There was no discernible difference between bladder shape prior to and at initiation of contraction. It was concluded that radiographic determination of a normal urinary bladder can be made without complete bladder distention and that cystograms and cystometrograms can be routinely performed simultaneously in dogs in which both procedures are required

  17. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  18. An experimental study on radiological examination of obstructed small bowel with various contrast media

    International Nuclear Information System (INIS)

    Lee, Yong; Kim, Sung Jin; Han, Moon Hee; Park, Jae Hyung

    1991-01-01

    For the evaluation of the level and cause of small bowel obstruction, an oral barium study is usually chosen. When perforation is whether barium or a water-soluble contrast agent should be used, because barium causes from foreign body reactions as well as adhesions in the extraluminal tissues. Water-soluble contrast agent, on the other hand, are less satisfactory but in general have no untoward effects in the extraluminal tissues. Because of hyperosomolarity, water-soluble contrast agents attract large amounts of fluid with subsequent dilution and loss of contrast and pose a risk of pulmonary edema if aspirated. The use of the newer non-ionic and low-osmolarity water-soluble contrast will likely avoid pulmonary complications due to aspiration. The author performed this experimental study to compare the radiological efficacy of different contrast media in enteric follow-through examinations of obstructed small bowel. Rate had a ligature applied to the distal ileum via laparotomy. Four contrast media were subjected to testing by instillation via oro-gastric tube immediately after laparotomy. Radiographs were exposed at 1, 4 and 8 hours and evaluated later. After 24 hours the animals were sacrificed and the stomach and small bowels, free from mesentery and omental tissue, were weighted with contrasts. The progression in the bowel was proportionate to the osmolarity of the contrast media. After 1 hour, the observations indicated sodium diatrizoate (Gastrografin, Schering) to be the least favorable medium with respect to sharpness of the mucosal border. After 8 hours, barium gave a poorer delineation compared to Ioxaglate (Hexabric, Guerbet) and Iopromide (Ultravist, Schering). Early deaths were noted in the sodium diatrizoate and ioxaglate groups. So we conclude that when using a rather high-volume bolus, low-osmolar non-ionic contrast media seem to have significant prospects for general diagnostic use in patients with suspected intestinal obstruction

  19. Accuracy of double-contrast arthrography and arthroscopy of the knee joint

    International Nuclear Information System (INIS)

    Thijn, C.J.P.

    1982-01-01

    Only in the diagnosis of medial meniscal lesions is double contrast arthrography superior to arthroscopy, provided that arthroscopy is carried out only from the anterolateral side (94% against 81% positive correlations). The rates in diagnosing lateral meniscal lesions are respectively 90% and 94.5%, in patellar chondropathy 55% and 99.5% respectively, and in diagnosting cruciate ligament lesions 69% and 97% respectively

  20. Accuracy of double-contrast arthrography and arthroscopy of the knee joint

    International Nuclear Information System (INIS)

    Thijn, C.J.P.

    1982-01-01

    Only in the diagnosis of medial meniscal lesions is double contrast arthrography superior to arthroscopy, provided that arthroscopy is carried out only from the anterolateral side (94% against 81% positive correlations). The rates in diagnosing lateral meniscal lesions are respectively 90% and 94.5%, in patellar chondropathy 55% and 99.5% respectively, and in diagnosting cruciate ligament lesions 69% and 97% respectively. (orig.)

  1. Bacterial Reduction Of Barium Sulphate By Sulphate-Reducing Bacteria

    Directory of Open Access Journals (Sweden)

    Luptáková Alena

    2015-12-01

    Full Text Available Acid mine drainage (AMD is a worldwide problem leading to contamination of water sources. AMD are characterized by low pH and high content of heavy metals and sulphates. The barium salts application presents one of the methods for the sulphates removing from AMD. Barium chloride, barium hydroxide and barium sulphide are used for the sulphates precipitation in the form of barium sulphate. Because of high investment costs of barium salts, barium sulphide is recycled from barium sulphate precipitates. It can be recycled by thermic or bacterial reduction of barium sulphate. The aim of our study was to verify experimentally the possibility of the bacterial transformation of BaSO4 to BaS by sulphate-reducing bacteria. Applied BaSO4 came from experiments of sulphates removal from Smolnik AMD using BaCl2.

  2. Patient radiation doses in upper GI examinations: a comparison between conventional and double-contrast techniques.

    Science.gov (United States)

    Bankvall, G; Owman, T

    1982-01-01

    A total of 60 patients, divided into 3 groups with 20 patients in each, were examined with 3 different techniques: group 1 -- conventional technique, exposure at 120 kV; group 2 -- double-contrast technique (hypotonic gastrography, HG), exposure at 80 kW; group 3 -- HG, exposure at 120 kV. All examinations were performed in the same examination room and by the same radiologist. Absorbed doses to skin, thyroid, breasts, and gonads as well as energy imparted were measured. The only significant dose enhancements found when using double-contrast instead of conventional technique were in the female breasts and then only if the voltage was in the lower range. With exposure at 120 kV there was little difference in absorbed dose, but a significant advantage with respect to energy was imparted when using a double-contrast technique instead of a conventional technique. The testes doses were very low in all 3 types of examinations, and it seems that use of a testes shield is hardly motivated. With regard to both diagnostic accuracy and patient radiation dose, there can be no reason to use a conventional technique for upper GI examinations.

  3. Barium aluminate cement: its application

    International Nuclear Information System (INIS)

    Drozdz, M.; Wolek, W.

    1975-01-01

    The technology of manufacturing barium aluminate cement from barium sulfate and alumina, using a rotary kiln for firing the clinker is described. The method of granulation of the homogenized charge was used. Conditions of using the ''to mud'' method in industry were indicated. The physical and chemical properties of barium aluminate cement are determined and the quality of several batches of cement prepared on a semi-industrial scale and their suitability for making highly refractory concretes are tested. The optimal composition of the concretes is determined as a function of the mixing water and barium aluminate cement contents. Several experimental batches of concretes were used in the linings of furnaces in the steel industry. The suitability of these cements for use in fields other than steelmaking is examined. It is established that calcium aluminate cement has certain limited applications [fr

  4. Edge detection of barium-filled stomach picture by one-dimensional collation method

    International Nuclear Information System (INIS)

    Nakamura, Shizuo

    1983-01-01

    The method for the contour edge detection of barium- filled stomach pictures by X-ray for the automatic screening is described using computer technique. It is necessary for the automatic screening of barium- filling pictures to detect accurately the outline of stomachs because the analysis of repletion pictures is performed by checking the disorder of marginal contours and abnormal stomach shapes. However, the detection of the coutour lines is difficult to be successful for the reason that the contrast of stomach pictures to background is low, a stomach is not necessarily filled completely with barium and the shadow of barium flowing into intestines is superimposed on stomach images and the shading is likely to occur. The engineering processing against these problems is not yet solved. In order to reduce the noise due to differential operator, the proposed method determines the boundary of a thing generally by the threshold value of density, and defines the edge of the thing from the differential waveform of density in the vicinity of the boundary. In addition, the method corrects the detection error caused by the local nonconformity of parameters by comparing the edges between the adjacent lines. As a result, in spite of its simple algorithm, the edges with good continuity and less noise can be detected, and the method is not much affected by shading. This method was found to be applicable to the images of others than stomachs. The extraction of the contour of barium- filling pictures requires the high level recognition processing instead of the simple conditioning. (Wakatsuki, Y.)

  5. Analysis of barium by isotope mass spectrometry

    International Nuclear Information System (INIS)

    Long Kaiming; Jia Baoting; Liu Xuemei

    2004-01-01

    The isotopic abundance ratios for barium at sub-microgram level are analyzed by thermal surface ionization mass spectrometry (TIMS). Rhenium trips used for sample preparation are firstly treated to eliminate possible barium background interference. During the preparation of barium samples phosphoric acid is added as an emitting and stabilizing reagent. The addition of phosphoric acid increases the collection efficiency and ion current strength and stability for barium. A relative standard deviation of 0.02% for the isotopic abundance ratio of 137 Ba to 138 Ba is achieved when the 138 Ba ion current is (1-3) x 10 -12 A. The experimental results also demonstrate that the isotope fractionation effect is negligibly small in the isotopic analysis of barium

  6. Oesophageal motility disorders - diagnosis with a barium-rice study

    International Nuclear Information System (INIS)

    Schwickert, H.C.; Schadmand-Fischer, S.; Klose, P.; Staritz, M.; Ueberschaer, B.; Thelen, M.

    1993-01-01

    The purpose of this study was to evaluate the role of a 'barium-rice' study for diagnosis of dysphagia and oesophageal motility disorders. Material and methods: 203 patients with oesophageal motility disorders of various aetiologies were examined by both conventional barium study and a 'barium-rice' study. During the latter, oesophageal clearance of a defined mixture of barium sulfate and boiled rice was measured. Results: The conventional barium study revealed prolonged transit time in only 15.8% (32 of 203 cases), whereas barium-rice study was pathological in 50.8% (103 of 203 cases). In 71 of 171 patients (41.5%) with a normal barium study, barium-rice passage was prolonged. In 23 patients, radiological results were confirmed by manometric measurements. Conclusion: Oesophageal motility disorders are detected by a barim-rice study with high sensitivity independent of the underlying disease. The barium-rice study offers a simple diagnostic tool revealing quantitative and reliable results. The barium-rice study is a suitable method for screening and follow-up of patients with dysphagia and oesophageal motility disorders. (orig.) [de

  7. Use of 3-dimensional computed tomography to detect a barium-masked fish bone causing esophageal perforation.

    Science.gov (United States)

    Tsukiyama, Atsushi; Tagami, Takashi; Kim, Shiei; Yokota, Hiroyuki

    2014-01-01

    Computed tomography (CT) is useful for evaluating esophageal foreign bodies and detecting perforation. However, when evaluation is difficult owing to the previous use of barium as a contrast medium, 3-dimensional CT may facilitate accurate diagnosis. A 49-year-old man was transferred to our hospital with the diagnosis of esophageal perforation. Because barium had been used as a contrast medium for an esophagram performed at a previous hospital, horizontal CT and esophageal endoscopy could not be able to identify the foreign body or characterize the lesion. However, 3-dimensional CT clearly revealed an L-shaped foreign body and its anatomical relationships in the mediastinum. Accordingly, we removed the foreign body using an upper gastrointestinal endoscope. The foreign body was the premaxillary bone of a sea bream. The patient was discharged without complications.

  8. Barite (Barium)

    Science.gov (United States)

    Johnson, Craig A.; Piatak, Nadine M.; Miller, M. Michael; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Barite (barium sulfate, BaSO4) is vital to the oil and gas industry because it is a key constituent of the mud used to drill oil and gas wells. Elemental barium is an additive in optical glass, ceramic glazes, and other products. Within the United States, barite is produced mainly from mines in Nevada. Imports in 2011 (the latest year for which complete data were available) accounted for 78 percent of domestic consumption and came mostly from China.Barite deposits can be divided into the following four main types: bedded-sedimentary; bedded-volcanic; vein, cavity-fill, and metasomatic; and residual. Bedded-sedimentary deposits, which are found in sedimentary rocks with characteristics of high biological productivity during sediment accumulation, are the major sources of barite production and account for the majority of reserves, both in the United States and worldwide. In 2013, China and India were the leading producers of barite, and they have large identified resources that position them to be significant producers for the foreseeable future. The potential for undiscovered barite resources in the United States and in many other countries is considerable, however. The expected tight supply and rising costs in the coming years will likely be met by increased production from such countries as Kazakhstan, Mexico, Morocco, and Vietnam.Barium has limited mobility in the environment and exposed barium in the vicinity of barite mines poses minimal risk to human or ecosystem health. Of greater concern is the potential for acidic metal-bearing drainage at sites where the barite ores or waste rocks contain abundant sulfide minerals. This risk is lessened naturally if the host rocks at the site are acid-neutralizing, and the risk can also be lessened by engineering measures.

  9. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  10. Bronchography in dogs. Comparative study with two barium sulphate solutions

    International Nuclear Information System (INIS)

    Thibaut, J.; Gallardo, P.; Vargas, L.; Deppe, R.; Born, R.

    1998-01-01

    Two solutions of barium sulphate, 60 and 30% w/v, were compared with the ''overflow'' Bronchographic method. Two groups of eight healthy adult does of both sexes, weighing 7 to 18 kg were used for the study. The dogs were anaesthetised with thiopentone sodium 2% (20 mg/kg iv). After intubation, each dog received contrast medium by a catheter connected to a syringe, in a 9 mi dose. Two series of two x-rays plates were taken in left lateral recumbent, 3 and 6 min after administering the contrast medium and in ventrodorsal projection, 30 sec. later. The x-ray plates obtained were analysed and compared intra and inter group considering the advance speed of the contrast medium, the radiographic density and outlines. Adverse reactions were controlled

  11. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients

    International Nuclear Information System (INIS)

    Wagner, Christian von; Smith, Samuel; Ghanouni, Alex; Power, Emily; Wardle, Jane; Halligan, Steve; Lilford, Richard J.; Morton, Dion; Dadswell, Edward; Atkin, Wendy

    2011-01-01

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE. (orig.)

  12. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients.

    Science.gov (United States)

    von Wagner, Christian; Smith, Samuel; Halligan, Steve; Ghanouni, Alex; Power, Emily; Lilford, Richard J; Morton, Dion; Dadswell, Edward; Atkin, Wendy; Wardle, Jane

    2011-10-01

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE.

  13. Complications encountered in contrast roentgenography of the colon

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.

    1983-01-01

    The following problems are analysed referring to the literature and to practical experience of the authors: - Types of complications encountered in contrast roentgenography or in endoscopy of the colon, and their frequency. - Risk factors and secondary injuries. Intestinal perforation is the most frequent complication experienced as a consequence of contrast barium enema. The main risk factors are to be seen in the use of balloon-tipped catheters, or of intestinal tubes with hard tips, in a rise of hydrostatic pressure above 80 cm water column, and in an excessively strong air insufflation. Frequency of complications for contrast barium enema is stated to be 0.002 p.c. (Welin and Welin, 1980) or 0.08 p.c. (Clark et al. 1961). The frequency of perforations in rectoscopy is shown to be in the same order of magnitude. For diagnostic colonoscopy, the frequency of complications is about one per mil. Existing diseases such as carcinoma, diverticulosis, diverticulitis, colitis ulcerosa, or morbus Crohn are factors enhancing the risk. Also, patients of advanced age are running a higher risk due to decreasing intestine wall elasticity with age. Previous biopsy or excision forbids contrast barium enema for the next two weeks. Injuries and sequelae to be expected after perforation are abscesses, phlegmon, peritonitis including formation of adhesion and bands, retroperitoneal fibrosis with formation of hydronephrosis, and anus praeter, the latter being temporary or permanent. An extensive literature survey covering 200 publications has been prepared and is available from the authors upon request. (orig.) [de

  14. Barium enema findings of milk allergy in infants

    International Nuclear Information System (INIS)

    Kim, Gyoung Ju; Kim, Mi Jeong; Lee, Hee Jung

    2006-01-01

    We wanted to evaluate the barium enema findings of milk allergy in infants. Retrospective evaluation of the plain abdominal radiography and barium enema findings was performed in fifteen young infants suffering with milk allergy. The presence of gaseous distension, rectal gas, paralytic ileus and mechanical obstruction was evaluated on the plain radiography. The presence of spasm, a transitional zone, a reversed rectosigmoid index and mucosal irregularity was analyzed on the barium enema; the presence of barium retention was also evaluated on 24-hour-delayed plain radiography. Paralytic ileus was the most common finding on the plain radiography (93%). On the barium enema, continuous spasm of the colon, ranging from the rectum to the descending colon, was revealed in ten infants (67%). A transitional zone was observed in one infant and a reversed rectosigmoid index was revealed in four. Mucosal irregularity was observed in two infants. Barium retention was demonstrated in 11 of fifteen cases: throughout the entire colon (n = 3), from the rectum to the descending colon (n = 7), and up to the transverse colon (n = 1). The most common barium enema finding of milk allergy in infants was spasm of the distal colon. The other findings were a transitional zone, a reversed rectosigmoid index, mucosal irregularity and barium retention

  15. INFLUENCE OF BARIUM OXIDE ADDITIONS ON PORTLAND CLINKER

    Directory of Open Access Journals (Sweden)

    Anezka Zezulova

    2016-12-01

    Full Text Available Nowadays, nuclear power plants are widespread around the world and research is of great interest. Together with nuclear research, shielding of different types of radiation is an important current topic of research aiming at their safety. Portland cement has been an elementary building material for centuries. Since barium is very efficient in shielding different types of radiation, it can be assumed that the radiation shielding capability of cement can be improved by incorporation of barium. This work deals with the influence of barium oxide, added in the form of barium carbonate and sulphate, on the formation and properties of Portland clinker. The structure of burnt clinkers and the ratio of clinker phases were studied by polarizing microscopy and by X-ray diffraction. With increasing barium content, the alite-belite ratio decreases and the content of free lime gradually increases. Moreover, sulphates induce the growth of alite crystals. The ability of barium to be a part of the clinker minerals was observed by scanning electron microscopy. Belite and clinker melt contain the highest amount of barium, but aggregates of barium oxide are formed in the clinker melt. Furthermore, the rate of alite crystallization was studied under isothermal conditions.

  16. Observed Barium Emission Rates

    Science.gov (United States)

    Stenbaek-Nielsen, H. C.; Wescott, E. M.; Hallinan, T. J.

    1993-01-01

    The barium releases from the CRRES satellite have provided an opportunity for verifying theoretically calculated barium ion and neutral emission rates. Spectra of the five Caribbean releases in the summer of 1991 were taken with a spectrograph on board a U.S. Air Force jet aircraft. Because the line of sight release densities are not known, only relative rates could be obtained. The observed relative rates agree well with the theoretically calculated rates and, together with other observations, confirm the earlier detailed theoretical emission rates. The calculated emission rates can thus with good accuracy be used with photometric observations. It has been postulated that charge exchange between neutral barium and oxygen ions represents a significant source for ionization. If so. it should be associated with emissions at 4957.15 A and 5013.00 A, but these emissions were not detected.

  17. High resolution studies of barium Rydberg states

    International Nuclear Information System (INIS)

    Eliel, E.R.

    1982-01-01

    The subtle structure of Rydberg states of barium with orbital angular momentum 0, 1, 2 and 3 is investigated. Some aspects of atomic theory for a configuration with two valence electrons are reviewed. The Multi Channel Quantum Defect Theory (MQDT) is concisely introduced as a convenient way to describe interactions between Rydberg series. Three high-resolution UV studies are presented. The first two, presenting results on a transition in indium and europium serve as an illustration of the frequency doubling technique. The third study is of hyperfine structure and isotope shifts in low-lying p states in Sr and Ba. An extensive study of the 6snp and 6snf Rydberg states of barium is presented with particular emphasis on the 6snf states. It is shown that the level structure cannot be fully explained with the model introduced earlier. Rather an effective two-body spin-orbit interaction has to be introduced to account for the observed splittings, illustrating that high resolution studies on Rydberg states offer an unique opportunity to determine the importance of such effects. Finally, the 6sns and 6snd series are considered. The hyperfine induced isotope shift in the simple excitation spectra to 6sns 1 S 0 is discussed and attention is paid to series perturbers. It is shown that level mixing parameters can easily be extracted from the experimental data. (Auth.)

  18. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  19. Atomization mechanisms for barium in furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Styris, D.L.

    1984-01-01

    Atomic absorption spectrometry and mass spectrometry are used simultaneously in order to elucidate atomization mechanisms of barium dichloride in pyrolytic graphite, vitreous carbon, and tantalum furnaces. Gas-phase barium dicarbide is observed to appear concurrently with the free barium. Barium oxide and barium dihydroxide precursors appear with the chlorides. Surface reactions involving species that are absorbed on the various furnaces are postulated to explain the appearances of the species that are observed in the gas phase. 49 references, 4 figures, 1 table

  20. Nanoparticles of barium induce apoptosis in human phagocytes.

    Science.gov (United States)

    Mores, Luana; França, Eduardo Luzia; Silva, Núbia Andrade; Suchara, Eliane Aparecida; Honorio-França, Adenilda Cristina

    2015-01-01

    Nutrients and immunological factors of breast milk are essential for newborn growth and the development of their immune system, but this secretion can contain organic and inorganic toxins such as barium. Colostrum contamination with barium is an important issue to investigate because this naturally occurring element is also associated with human activity and industrial pollution. The study evaluated the administration of barium nanoparticles to colostrum, assessing the viability and functional activity of colostral mononuclear phagocytes. Colostrum was collected from 24 clinically healthy women (aged 18-35 years). Cell viability, superoxide release, intracellular Ca(2+) release, and phagocyte apoptosis were analyzed in the samples. Treatment with barium lowered mononuclear phagocyte viability, increased superoxide release, and reduced intracellular calcium release. In addition, barium increased cell death by apoptosis. These data suggest that nanoparticles of barium in colostrum are toxic to cells, showing the importance of avoiding exposure to this element.

  1. Micro-computed tomography of fatigue microdamage in cortical bone using a barium sulfate contrast agent.

    Science.gov (United States)

    Leng, Huijie; Wang, Xiang; Ross, Ryan D; Niebur, Glen L; Roeder, Ryan K

    2008-01-01

    Accumulation of microdamage during fatigue can lead to increased fracture susceptibility in bone. Current techniques for imaging microdamage in bone are inherently destructive and two-dimensional. Therefore, the objective of this study was to image the accumulation of fatigue microdamage in cortical bone using micro-computed tomography (micro-CT) with a barium sulfate (BaSO(4)) contrast agent. Two symmetric notches were machined on the tensile surface of bovine cortical bone beams in order to generate damage ahead of the stress concentrations during four-point bending fatigue. Specimens were loaded to a specified number of cycles or until one notch fractured, such that the other notch exhibited the accumulation of microdamage prior to fracture. Microdamage ahead of the notch was stained in vitro by precipitation of BaSO(4) and imaged using micro-CT. Reconstructed images showed a distinct region of bright voxels around the notch tip or along propagating cracks due to the presence of BaSO(4), which was verified by backscattered electron imaging and energy dispersive spectroscopy. The shape of the stained region ahead of the notch tip was consistent with principal strain contours calculated by finite element analysis. The relative volume of the stained region was correlated with the number of loading cycles by non-linear regression using a power-law. This study demonstrates new methods for the non-destructive and three-dimensional detection of fatigue microdamage accumulation in cortical bone in vitro, which may be useful to gain further understanding into the role of microdamage in bone fragility.

  2. Barium appendicitis after upper gastrointestinal imaging.

    Science.gov (United States)

    Novotny, Nathan M; Lillemoe, Keith D; Falimirski, Mark E

    2010-02-01

    Barium appendicitis (BA) is a rarely seen entity with fewer than 30 reports in the literature. However, it is a known complication of barium imaging. To report a case of BA in a patient whose computed tomography (CT) scan was initially read as foreign body ingestion. An 18-year-old man presented with right lower quadrant pain after upper gastrointestinal imaging 2 weeks prior. A CT scan was obtained of his abdomen and pelvis that revealed a finding that was interpreted as a foreign body at the area of the terminal ileum. A plain X-ray study of the abdomen revealed radiopaque appendicoliths. Pathology confirmed the diagnosis of barium appendicitis. BA is a rare entity and the pathogenesis is unclear. Shorter intervals between barium study and presentation with appendicitis usually correlate with fewer complications. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  3. Comparison of contrast media for visualization of the colon of healthy dogs during computed tomography and ultrasonography.

    Science.gov (United States)

    Cheon, Byunggyu; Moon, Sohyeon; Park, Seungjo; Lee, Sang-Kwon; Hong, Sunghwa; Cho, Hyun; Choi, Jihye

    2016-11-01

    OBJECTIVE To evaluate contrast agents for their ability to improve visualization of the colon wall and lumen during CT and ultrasonography. ANIMALS 10 healthy adult Beagles. PROCEDURES Food was withheld from dogs for 36 hours, after which dogs consumed 250 mL of polyethylene glycol solution. Dogs were then anesthetized, a contrast agent (tap water, diluted barium, or air; order randomly assigned) was administered rectally, iodine contrast medium (880 mg of I/kg) was administered IV, and CT and ultrasonography of the colon were performed. After a 1-week washout period, this process was repeated with a different contrast agent until all agents had been evaluated. Two investigators reviewed the CT and ultrasonographic images for colon wall thickness, conspicuity, artifacts, wall layering, and degree of lumen dilation at 4 sites. RESULTS Thickness of the colon wall was greatest in CT and ultrasonographic images with water used as contrast agent, followed by barium and then air. The CT images obtained after water administration had a smooth appearance that outlined the colonic mucosa and had the highest score of the 3 contrast agents for wall conspicuity. Although no substantial artifacts related to any of the contrast agents were identified on CT images, barium- and gas-induced shadowing and reverberation artifacts hindered wall evaluation during ultrasonography. For ultrasonography, the degree of conspicuity was highest with barium in the near-field wall and with water in the far-field wall. In contrast to CT, ultrasonography could be used to distinguish wall layering, and the mucosal and muscular layers were distinct with all contrast agents. CONCLUSIONS AND CLINICAL RELEVANCE Use of water as a contrast agent for both CT and ultrasonography of the colon in dogs compensated for each imaging modality's disadvantages and could be beneficial in the diagnosis of colon disease.

  4. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Christian von; Smith, Samuel; Ghanouni, Alex; Power, Emily; Wardle, Jane [University College London, Department of Epidemiology and Public Health, London (United Kingdom); Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College Hospital, Centre for Medical Imaging, London (United Kingdom); Lilford, Richard J. [Birmingham University, Department of Epidemiology, Birmingham (United Kingdom); Morton, Dion [Birmingham University, Department of Surgery, Birmingham (United Kingdom); Dadswell, Edward; Atkin, Wendy [Imperial College London, Department of Surgery and Cancer, London (United Kingdom)

    2011-10-15

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE. (orig.)

  5. Cost-effectiveness of barium enemas performed by radiographers

    International Nuclear Information System (INIS)

    Brown, Lorraine; Desai, Sharad

    2002-01-01

    AIM: To assess the cost-effectiveness of barium enemas performed by radiographers compared to those performed by consultant radiologists. METHOD: Prospective study of 200 barium enemas carried out by a senior radiographer and a consultant radiologist. The sample was a consecutive sample of adult out-patients over a 3-month period, with no exclusion. The length of time of the enema and the numbers and grades of staff involved in the procedure were recorded. This was translated into staffing costs using the appropriate pay scales. RESULTS: The barium enemas performed by the superintendent radiographer were more cost-effective than those performed by the consultant radiologist (1406 pounds for 100 radiographer-performed barium enemas compared to 1787 pounds for 100 carried out by the consultant radiologist). CONCLUSION: In terms of staffing costs, radiographers performing barium enemas not only liberates radiologist time, it is also a cost-effective method of providing an out-patient barium enema service. Brown, L. and Desai, S. (2002)

  6. Kinematic and spatial distributions of barium stars - are the barium stars and Am stars related?

    International Nuclear Information System (INIS)

    Hakkila, J.

    1989-01-01

    The possibility of an evolutionary link between Am stars and barium stars is considered, and an examination of previous data suggests that barium star precursors are main-sequence stars of intermediate mass, are most likely A and/or F dwarfs, and are intermediate-mass binaries with close to intermediate orbital separations. The possible role of mass transfer in the later development of Am systems is explored. Mass transfer and loss from systems with a range of masses and orbital separations may explain such statistical peculiarities of barium stars as the large dispersion in absolute magnitude, the large range of elemental abundances from star to star, and the small number of stars with large peculiar velocities. 93 refs

  7. In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo

    International Nuclear Information System (INIS)

    Li Beilei; Xu Min; Shi Hongcheng; Chen Shaoliang; Wu Weizhong; Peng Guanyun; Zhang Xi; Peng Yifeng

    2012-01-01

    Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors. Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method. Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility. Barium sulfate and physiological saline were used as contrast agents for the blood vessels. Blood vessels of <Φ20 μm could be detected by replacing resident blood with physiological saline or barium sulfate. An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image. It is demonstrated that selective angiography based on phase contrast X-ray imaging, with a physiological material of low Z elements (such as saline) being the contrast agent, is a viable imaging strategy. Further efforts will be focused on using the technique to image tumor angiogenesis. (authors)

  8. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    Science.gov (United States)

    Carrel, Maxence; Beltran, Mario A; Morales, Verónica L; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development

  9. Enterogastroesophageal reflux during barium enema: Report of a case

    International Nuclear Information System (INIS)

    Shin, Hyoun Ja; Rhee, Hak Song

    1972-01-01

    Enterogastric reflux during barium enema examination has been ascribed to various causes including incompetence of the ilepcecal valve, shunt, fistula, excessive barium etc. Recently we have encountered a case of complete enterogastroesphageal regurgitation during barium enema examination performed for the reduction of the ileocolic intuosusception in 6 months old baby. The regurgitation occurred only in the first of two barium enema examinations conducted at one month interval for recurring intussusception. The barium-saline solution used in the present study was not more than 350 ml in quantity. No organic or physical causes of such a complete regurgitation could be determined

  10. Laser cooling and trapping of barium

    NARCIS (Netherlands)

    De, Subhadeep

    2008-01-01

    Laser cooling and trapping of heavy alkaline-earth element barium have been demonstrated for the first time ever. For any possible cycling transition in barium that could provide strong cooling forces, the excited state has a very large branching probability to metastable states. Additional lasers

  11. Contrast media for radiological examination in gastrointestinal tract leakage

    International Nuclear Information System (INIS)

    Ginai-Karamat, A.Z.

    1987-01-01

    The aim of this investigation has been to find a safe and suitable contrast medium (CM) for radiological evaluation of the gastrointestinal tract (GIT) in cases where leakage outside the GIT can be suspected. An experimental study was carried out to evaluate the reactions of various available CM in the bronchi and lungs, mediastinum, pleura and peritoneum of rats. The CM evaluated in the experimental study were, pure barium sulphate (without any additives), commercial barium sulphate (Micropaque, with additives), Dionosil, Hytrast, Gastrografin, Amipaque (in pleura Omnipaque) and Hexabrix. (Auth.)

  12. Bioadhesive agents in addition to oral contrast media - evaluation in an animal model

    International Nuclear Information System (INIS)

    Conrad, R.; Schneider, G.; Textor, J.; Schild, H.H.; Fimmers, R.

    1998-01-01

    Purpose: To evaluate the additional effect of bioadhesives in combination with iotrolan and barium as oral contrast media in an animal model. Method: The bioadhesives Noveon, CMC, Tylose and Carbopol 934 were added to iotrolan and barium. The solutions were administered to rabbits by a feeding tube. The animals were investigated by computed tomography (CT) and radiography after 0,5, 4, 12, 24 and in part after 48 hours. Mucosal coating and contrast filling of the bowel were evaluated. Results: Addition of bioadhesives to oral contrast media effected long-term contrast in the small intestine and colon, but no improvement in continuous filling and coating of the gastrointestinal tract was detected. Mucosal coating was seen only in short regions of the caecum and small intestine. In CT the best results for coating were observed with tylose and CMC, in radiography additionally with carbopol and noveon. All contrast medium solutions were well tolerated. Conclusion: The evaluated contrast medium solutions with bioadhesives have shown long-term contrast but no improvement in coating in comparison to conventional oral contrast media. (orig.) [de

  13. [The value of double contrast arthrotomography combined with cinematography in the diagnosis of functional and structural TMJ alterations].

    Science.gov (United States)

    Engelke, W; Grossniklaus, B; Sailer, H F

    1991-01-01

    Double contrast arthrotomography combined with cinematography as a diagnostic instrument establishing functional and structural TMJ alterations is evaluated for its diagnostic value and reliability within the chain of diagnostic measures applied. In 131 patients double-contrast arthrotomography was followed by a comprehensive history of joint problems, and verification of the clinical findings as well as the arthrographic diagnosis and the post-arthrographic TMJ alterations. Our interest was focussed, among others, on the question whether arthrography alone would have any therapeutic effect or produce an alteration in TMJ function.

  14. Significance of demonstrating areae gastricae at hypotonic double contrast examination of the stomach

    Energy Technology Data Exchange (ETDEWEB)

    Rienmueller, R. (Muenchen Univ. (Germany, F.R.). Klinik und Poliklinik fuer Radiologie)

    1980-05-01

    150 patients were examined by the double contrast-technique in drug-induced hypotonia of the stomach. They were examined gastroscopically and at the same time biopsies were taken. Comparison of histological and radiological results was performed. There was found an agreement of 82% in the performance of areae gastricae and the histological diagnosis of chronic gastritis.

  15. Barium determination in gastric contents, blood and urine by inductively coupled plasma mass spectrometry in the case of oral barium chloride poisoning.

    Science.gov (United States)

    Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Hanć, Anetta; Grzegorowski, Adam; Barałkiewicz, Danuta; Gaca, Michał; Zielińska-Psuja, Barbara

    2014-01-01

    A serious case of barium intoxication from suicidal ingestion is reported. Oral barium chloride poisoning with hypokalemia, neuromuscular and cardiac toxicity, treated with intravenous potassium supplementation and hemodialysis, was confirmed by the determination of barium concentrations in gastric contents, blood, serum and urine using the inductively coupled plasma mass spectrometry method. Barium concentrations in the analyzed specimens were 20.45 µg/L in serum, 150 µg/L in blood, 10,500 µg/L in urine and 63,500 µg/L in gastric contents. Results were compared with barium levels obtained from a non-intoxicated person. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Coprecipitation of iron and silver with barium fluoride

    International Nuclear Information System (INIS)

    Kopilova, N.V.; Khamidov, B.O.; Kashina, Z.A.; Ikrami, D.D.

    1986-01-01

    Distribution of trace contaminants of iron and silver at coprecipitation of barium fluoride is studied in present work. It is defined that iron almost completely coprecipitated with barium fluoride in wide range of ph 5.5-12. Silver coprecipitated with barium fluoride in ph range 4-7. The value of coprecipitation varies from 94% to 100%.

  17. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  18. Synthesis, photoluminescence and magnetic properties of barium vanadate nanoflowers

    International Nuclear Information System (INIS)

    Xu, Jing; Hu, Chenguo; Xi, Yi; Peng, Chen; Wan, Buyong; He, Xiaoshan

    2011-01-01

    Graphical abstract: The flower-shaped barium vanadate was obtained for the first time. The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. Research highlights: → In the paper, the flower-shaped barium vanadate were obtained for the first time. The CHM method used here is new and simple for preparation of barium vanadate. → The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. The strong bluish-green emission was observed. → The ferromagnetic behavior of the barium vanadate nanoflowers was found with saturation magnetization of about 83.50 x 10 -3 emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10 -3 emu/g. → The mechanisms of PL and magnetic property of barium vanadate nanoflowers have been discussed. -- Abstract: The flower-shaped barium vanadate has been obtained by the composite hydroxide mediated (CHM) method from V 2 O 5 and BaCl 2 at 200 o C for 13 h. XRD and XPS spectrum of the as-synthesized sample indicate it is hexagonal Ba 3 V 2 O 8 with small amount of Ba 3 VO 4.8 coexistence. Scan electron microscope and transmission electron microscope display that the flower-shaped crystals are composed of nanosheets with thickness of ∼20 nm. The UV-visible spectrum shows that the barium vanadate sample has two optical gaps (3.85 eV and 3.12 eV). Photoluminescence spectrum of the barium vanadate flowers exhibits a visible light emission centered at 492 and 525 nm which might be attributed to VO 4 tetrahedron with T d symmetry in Ba 3 V 2 O 8 . The ferromagnetic behavior of the barium vanadate nanoflowers has been found with saturation magnetization of about 83.50 x 10 -3 emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10 -3 emu/g, which is mainly due to the presence of a non-orthovanadate phase with spin S = 1/2.

  19. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium calcium...

  20. History and challenges of barium titanate: Part I

    Directory of Open Access Journals (Sweden)

    Vijatović M.M.

    2008-01-01

    Full Text Available Barium titanate is the first ferroelectric ceramics and a good candidate for a variety of applications due to its excellent dielectric, ferroelectric and piezoelectric properties. Barium titanate is a member of a large family of compounds with the general formula ABO3 called perovskites. Barium titanate can be prepared using different methods. The synthesis method depends on the desired characteristics for the end application. The used method has a significant influence on the structure and properties of barium titanate materials. In this review paper, Part I contains a study of the BaTiO3 structure and frequently used synthesis methods.

  1. The failed postoperative shoulder: Role of double contrast CT arthrography

    International Nuclear Information System (INIS)

    Singson, R.D.; Feldman, F.; Bigliani, L.

    1986-01-01

    Various types of reparative and corrective operations on the shoulder joint are being increasingly undertaken. Defining residual, new, or acutely acquired pathology in the postoperative period is exceedingly difficult because of extensive surgical alterations. Since patients may be symptomatic or recurrently symptomatic postoperatively, judgments must be made regarding the failure of the initial repair, or new superimposed insults. CT double-contrast arthrography, performed in a series of symptomatic patients after shoulder arthroplasty for instability, successfully demonstrated responsible residual or recurrent pathologic processes, including persistent Bankart lesions, glenoid rim fractures, improper hardware placement, and migration of metallic hardware. These and other examples of pathology are illustrated and discussed

  2. Microcapsules with intrinsic barium radiopacity for immunoprotection and X-ray/CT imaging of pancreatic islet cells.

    Science.gov (United States)

    Arifin, Dian R; Manek, Sameer; Call, Emma; Arepally, Aravind; Bulte, Jeff W M

    2012-06-01

    Microencapsulation is a commonly used technique for immunoprotection of engrafted therapeutic cells. We investigated a library of capsule formulations to determine the most optimal formulation for pancreatic beta islet cell transplantation, using barium as the gelating ion and clinical-grade protamine sulfate (PS) as a new cationic capsule cross-linker. Barium-gelated alginate/PS/alginate microcapsules (APSA, diameter = 444 ± 21 μm) proved to be mechanically stronger and supported a higher cell viability as compared to conventional alginate/poly-l-lysine/alginate (APLLA) capsules. Human pancreatic islets encapsulated inside APSA capsules, gelated with 20 mm barium as optimal concentration, exhibited a sustained morphological integrity, viability, and functionality for at least 3-4 weeks in vitro, with secreted human C-peptide levels of 0.2-160 pg/ml/islet. Unlike APLLA capsules that are gelled with calcium, barium-APSA capsules are intrinsically radiopaque and, when engrafted into mice, could be readily imaged in vivo with micro-computed tomography (CT). Without the need of adding contrast agents, these capsules offer a clinically applicable alternative for simultaneous immunoprotection and real-time, non-invasive X-ray/CT monitoring of engrafted cells during and after in vivo administration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Blood pressure changes during barium enema

    International Nuclear Information System (INIS)

    Roach, S.C.; Martin, O.J.D.; Owen, A.; Martin, D.F.

    2001-01-01

    AIMS: To document blood pressure changes during barium enema examination and to determine at what point in the examination changes are likely to occur. METHODS AND RESULTS: Blood pressure measurements were taken at seven points during the course of barium enema examination in 107 consecutive patients. We found that patients over the age of 60 years had statistically significant decreases in blood pressure when they were stood up during the course of the examination. Many of these patients were asymptomatic. Patients who had symptoms (15/107, 14%) when standing up had a degree of hypotension. The duration of barium enema examination is longer in those patients who experience symptoms. CONCLUSION: During a barium enema examination hypotension occurs at the point of standing up more frequently in patients over 60 years and in those who suffer symptoms at this time. Patients who fall into one of these groups should be considered at risk of fainting at this point in the examination. A modified technique to avoid standing should be considered in at-risk patients. Roach, S.C. et al. (2001)

  4. An improved contrast enhancement algorithm for infrared images based on adaptive double plateaus histogram equalization

    Science.gov (United States)

    Li, Shuo; Jin, Weiqi; Li, Li; Li, Yiyang

    2018-05-01

    Infrared thermal images can reflect the thermal-radiation distribution of a particular scene. However, the contrast of the infrared images is usually low. Hence, it is generally necessary to enhance the contrast of infrared images in advance to facilitate subsequent recognition and analysis. Based on the adaptive double plateaus histogram equalization, this paper presents an improved contrast enhancement algorithm for infrared thermal images. In the proposed algorithm, the normalized coefficient of variation of the histogram, which characterizes the level of contrast enhancement, is introduced as feedback information to adjust the upper and lower plateau thresholds. The experiments on actual infrared images show that compared to the three typical contrast-enhancement algorithms, the proposed algorithm has better scene adaptability and yields better contrast-enhancement results for infrared images with more dark areas or a higher dynamic range. Hence, it has high application value in contrast enhancement, dynamic range compression, and digital detail enhancement for infrared thermal images.

  5. Clinical Diagnosis of Achalasia: How Reliable is the Barium X-Ray?

    Directory of Open Access Journals (Sweden)

    I El-Takli

    2006-01-01

    Full Text Available Manometry is considered to be the gold standard for the diagnosis of achalasia. However, many physicians believe that contrast radiography, classically showing esophageal dilation with bird-beak narrowing of the gastroesophageal junction, is also accurate in either diagnosing or excluding the disorder. The aim of the current study was to determine the accuracy of barium x-ray in the diagnosis of achalasia. The radiological diagnosis of all patients manometrically diagnosed with achalasia (using conventional criteria between January 1994 and June 1998 were reviewed. A total of 51 cases of achalasia were identified. Thirteen patients were excluded because they either did not have contrast radiography before a manometric diagnosis or had their x-rays performed more than six months previously. Of the remaining 38 patients, achalasia was stated as a diagnostic possibility in the radiologists report in only 22 (58% of those patients. Achalasia was not considered in the remaining 16 patients: two were reported as normal, four as having stenosis/narrowing in distal esophagus, two as having presbyesophagus, one as having mild gastroesophageal reflux and seven as having nonspecific dysmotility. To determine the reason for the diagnostic failure of the barium x-ray, an expert gastrointestinal radiologist reviewed 12 of the nondiagnostic x-rays in a blinded fashion, interspersed with 10 randomly selected esophageal-contrast radiographs from control subjects to avoid bias. Of these initially nondiagnostic x-rays in achalasia patients, typical radiological features of achalasia were deemed to be present in 50%. The present study indicates that contrast radiography lacks sensitivity in the diagnosis of achalasia. This is not only due to radiologist oversight but also because of the absence of the characteristic radiological features in many cases. This reinforces the important role of esophageal manometry in patients with persistent nonstructural dysphagia.

  6. Barium transport in the hot spot region of fluorescent lamps

    International Nuclear Information System (INIS)

    Sigeneger, F; Rackow, K; Uhrlandt, D; Ehlbeck, J; Lieder, G

    2010-01-01

    The transport of barium atoms and ions in the vicinity of the hot spot in fluorescent lamps operating at 25 kHz is investigated by a combined experimental and theoretical approach. By laser-induced fluorescence, the particle densities of barium atoms and ions were measured time-resolved at different distances from the spot centre. In addition, the time-dependent cathode fall voltage was measured using an improved band method. The model combines a kinetic part for the electrons with a fluid part for the barium atoms and ions. Both parts are spatially resolved in spherically symmetric geometry. The space-dependent electron Boltzmann equation yields the electron density and the ionization rate coefficient of barium as functions of the cathode fall voltage. These results are used to solve the time-dependent particle balance equations of barium atoms and ions which include the ionization of barium as gain and loss terms, respectively. Good agreement between the measured and calculated particle densities of barium atoms is obtained. A sensitive dependence of the ionization frequency and of the barium particle densities on the cathode fall voltage was found.

  7. Creating unstable velocity-space distributions with barium injections

    International Nuclear Information System (INIS)

    Pongratz, M.B.

    1983-01-01

    Large Debye lengths relative to detector dimensions and the absence of confining walls makes space an attractive laboratory for studying fundamental theories of plasma instabilities. However, natural space plasmas are rarely found displaced from equilibrium enough to permit isolation and diagnosis of the controlling parameters and driving conditions. Furthermore, any plasma or field response to the departure from equilibrium can be masked by noise in the natural system. Active experiments provide a technique for addressing the chicken or egg dilemma. Early thermite barium releases were generally conducted at low altitudes from sounding rockets to trace electric fields passively or to study configuration-space instabilities. One can also study velocity-space instabilities with barium releases. Neutral barium vapor releases wherein a typical speed greatly exceeds the thermal speed can be used to produce barium ion velocity-space distributions that should be subject to a number of microinstabilities. We examine the ion velocity-space distributions resulting from barium injections from orbiting spacecraft and shaped-charges

  8. Evaluation of gastrointestinal tract transit times using barium-impregnated polyethylene spheres and barium sulfate suspension in a domestic pigeon (Columba livia) model.

    Science.gov (United States)

    Bloch, Rebecca A; Cronin, Kimberly; Hoover, John P; Pechman, Robert D; Payton, Mark E

    2010-03-01

    Barium impregnated polyethylene spheres (BIPS) are used in small animal medicine as an alternative to barium sulfate for radiographic studies of the gastrointestinal tract. To determine the usefulness of BIPS as an alternative to barium suspension in measuring gastrointestinal (GI) transit time for avian species, ventrodorsal radiographs were used to follow the passage of BIPS and 30% barium sulfate suspension through the GI tracts of domestic pigeons (Columba livia). Gastrointestinal transit times of thirty 1.5-mm BIPS administered in moistened gelatin capsules and 30% barium sulfate suspension gavaged into the crop were compared in 6 pigeons. Although the barium suspension passed out of the GI tract of all pigeons within 24 hours, the 1.5-mm BIPS remained in the ventriculus for 368.0 +/- 176.8 hours and did not clear the GI tract for 424.0 +/- 204.6 hours. Although the times for passage of BIPS and 30% barium sulfate suspension from the crop into the ventriculus were not significantly different (P = .14), the times for passage of BIPS from the ventriculus into the large intestine-cloaca and for clearance from the GI tract of the pigeons were significantly longer (P barium sulfate suspension. From the results of this study, we conclude that BIPS are not useful for radiographically evaluating GI transit times in pigeons and are unlikely to be useful in other avian species that have a muscular ventriculus. BIPS may or may not be useful for evaluating GI transit times in species that lack a muscular ventriculus.

  9. Estudo comparativo dos meios de contraste baritado e iodado-iônico e não-iônico no trato respiratório de ratos Comparative study of barium and iodine agents - ionic and nonionic on the respiratory tract of the rats

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Pessole Biondo-Simões

    2003-10-01

    determine the changes in the respiratory tract triggered by the presence of contrast medium. METHODS: Ninety-one rats were divided at random into 5 groups, i.e., an intact control group of 7 animals and 4 groups of 21 rats each. The manipulated control group received physiological saline and the experimental groups respectively received barium, ionic iodine and non-ionic iodine. Under anesthesia and direct visualization of the trachea, 0.75 ml/kg (0.25 ml of the contrast medium was injected into the animals of each group. The effects of the procedure were determined after 1 hour, 1 day and 1 week, with the animals being sacrificed at each time point by drawing lots. Radiographic documentation was obtained, followed by resection and histopathologic examination of the lungs. RESULTS: After 1 hour, the middle fields and the right upper field were involved in the group injected with barium. In the groups injected with ionic iodine and non-ionic iodine, the entire right lung was found to be opacified. After 1 day and 1 week, the groups injected with iodine were normal, whereas the group injected with barium showed involvement of the middle fields. After 1 week, histopathologic examination revealed that the group injected with barium exhibited large amounts of intra-alveolar, perivascular and peribronchial macrophages CONCLUSION: The ionic and non-ionic iodine contrast media led to temporary changes, whereas barium promoted a chronic inflammatory reaction with maintenance of radiographic translation.

  10. Dynamical symmetry breaking in barium isotopes

    International Nuclear Information System (INIS)

    Rawat, Bir Singh; Chattopadhyay, P.K.

    1997-01-01

    The isotopes of Xe with mass numbers 124, 126, 128, 130 and the isotopes of barium with mass numbers 128, 130, 132, 134 were shown to correspond to the O(6) dynamical symmetry of IBM. In the investigation of the dynamical symmetry breaking in this region, the barium isotopes for departures from O(6) symmetry have been studied

  11. Late changes in barium sulfate aspiration: HRCT features

    International Nuclear Information System (INIS)

    Voloudaki, A.; Ergazakis, N.; Gourtsoyiannis, N.

    2003-01-01

    Aspiration of barium sulfate occurs accidentally. Lung reaction is usually mild in the early phase due to inert character of the substance and long-term reactions or late toxicities are not expected. Little if any fibrotic response is speculated. We present a case with barium aspiration, studied by high-resolution computed tomography (HRCT) 1 year after the event, as late pulmonary sequelae studied by CT have not been described yet, to the best of our knowledge. The HRCT revealed thickened interlobular septa, subpleural lines, subpleural cysts, and centrilobular micronodules along with barium particles in a subpleural distribution. Those findings indicated that barium is capable of producing mild though silent clinically fibrosis. (orig.)

  12. History and Evolution of the Barium Swallow for Evaluation of the Pharynx and Esophagus.

    Science.gov (United States)

    Levine, Marc S; Rubesin, Stephen E

    2017-02-01

    This article reviews the history of the barium swallow from its early role in radiology to its current status as an important diagnostic test in modern radiology practice. Though a variety of diagnostic procedures can be performed to evaluate patients with dysphagia or other pharyngeal or esophageal symptoms, the barium study has evolved into a readily available, non-invasive, and cost-effective technique that can facilitate the selection of additional diagnostic tests and guide decisions about medical, endoscopic, or surgical management. This article focuses on the evolution of fluoroscopic equipment, radiography, and contrast media for evaluating the pharynx and esophagus, the importance of understanding pharyngoesophageal relationships, and major advances that have occurred in the radiologic diagnosis of select esophageal diseases, including gastroesophageal reflux disease, infectious esophagitis, eosinophilic esophagitis, esophageal carcinoma, and esophageal motility disorders.

  13. Safety of Contrast Material Use During Pregnancy and Lactation.

    Science.gov (United States)

    Puac, Paulo; Rodríguez, Andrés; Vallejo, Carina; Zamora, Carlos A; Castillo, Mauricio

    2017-11-01

    The use of contrast media to image patients who are pregnant has increased during the past decades worldwide. Their use in pregnancy and in patients who are lactating remains a challenging issue for radiologists and other physicians. This article addresses the different types of contrast media that may be used in such patients according to the imaging modality (iodinated contrast media, barium, gadolinium-based, and ultrasound contrast agents), focusing on their adverse effects, potential teratogenic effects, strategies to minimize risks, and current clinical recommendation. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. SALT reveals the barium central star of the planetary nebula Hen 2-39

    Science.gov (United States)

    Miszalski, B.; Boffin, H. M. J.; Jones, D.; Karakas, A. I.; Köppen, J.; Tyndall, A. A.; Mohamed, S. S.; Rodríguez-Gil, P.; Santander-García, M.

    2013-12-01

    Classical barium stars are binary systems which consist of a late-type giant enriched in carbon and slow neutron capture (s-process) elements and an evolved white dwarf (WD) that is invisible at optical wavelengths. The youngest observed barium stars are surrounded by planetary nebulae (PNe), ejected soon after the wind accretion of polluted material when the WD was in its preceding asymptotic giant branch (AGB) phase. Such systems are rare but powerful laboratories for studying AGB nucleosynthesis as we can measure the chemical abundances of both the polluted star and the nebula ejected by the polluter. Here, we present evidence for a barium star in the PN Hen 2-39 (PN G283.8-04.2) as one of only a few known systems. The polluted giant is very similar to that found in WeBo 1 (PN G135.6+01.0). It is a cool (Teff = 4250 ± 150 K) giant enhanced in carbon ([C/H] = 0.42 ± 0.02 dex) and barium ([Ba/Fe] = 1.50 ± 0.25 dex). A spectral type of C-R3 C24 nominally places Hen 2-39 amongst the peculiar early R-type carbon stars; however, the barium enhancement and likely binary status mean that it is more likely to be a barium star with similar properties, rather than a true member of this class. An AGB star model of initial mass 1.8 M⊙ and a relatively large carbon pocket size can reproduce the observed abundances well, provided mass is transferred in a highly conservative way from the AGB star to the polluted star (e.g. wind Roche lobe overflow). It also shows signs of chromospheric activity and photometric variability with a possible rotation period of ˜5.5 d likely induced by wind accretion. The nebula exhibits an apparent ring morphology in keeping with the other PNe around barium stars (WeBo 1 and A 70) and shows a high degree of ionization implying the presence of an invisible hot pre-WD companion that will require confirmation with UV observations. In contrast to A 70, the nebular chemical abundance pattern is consistent with non-Type I PNe, in keeping with the

  16. Detection of gastritis by single- and double-contrast radiography

    International Nuclear Information System (INIS)

    Thoeni, R.F.; Goldberg, H.I.; Ominsky, S.; Cello, J.P.

    1983-01-01

    Sixty-eight patients with various types of gastritis, 23 patients with normal stomachs, and four patients with other gastric diseases were examined in a prospective study to assess the sensitivity and specificity of single-contrast (SC) and double-contrast (DC) upper gastrointestinal examinations in the evaluation of gastritis. All patients underwent endoscopy with biopsy followed first by DC and then by SC radiography. The respective sensitivities of SC and DC radiography were 58% and 72% for all examinations and 59% and 77% for adequate examinations only. The respective specificities were 59% and 55% based on all examinations. Useful radiographic features included polypoid defects and erosions detected by both methods, abnormal folds and flattened margins detected by the SC technique, and narrowed lumen and crenulated margins detected by the DC technique. In 93% of all cases, the correct diagnosis was based on two or more of these radiographic features. According to this study, the radiographic sensitivity in the detection of gastritis is reliable only in cases of moderate-to-severe disease and only when based on findings of the DC examination. Neither SC nor DC radiography should be used as the primary screening method for patients with suspected gastritis, and the radiographic diagnosis should be restricted to the terms ''erosive'' or ''nonerosive gastritis.''

  17. Barium low concentration determination in solutions using X rays energy spectrometry

    International Nuclear Information System (INIS)

    Barbosa, Joao Batista Santos; Pereira, Jose dos Santos Jorge

    1999-01-01

    This work was proposed to establish an analytical methodology for barium determination in samples from the Waste Supervision of CDTN. Barium is the focus here because it has the same chemical behaviour as radium. Therefore, barium can replace it as an inactive tracer in contention matrix studies. The methodology is made up of two phases; physical concentration and barium determination by an Energy Dispersive Spectrometer using an Am 241 photon excitation system. A very good set of results is found when Am 241 is used in fluorescing barium atoms. This fact, in addition to the physical concentration process, allows to detect up 12 ppb of elementary barium. (author)

  18. Electrooptic and piezoelectric measurements in photorefractive barium titanate and strontium barium niobate

    International Nuclear Information System (INIS)

    Ducharme, S.; Feinberg, J.; Neurgaonkar, R.R.

    1987-01-01

    The authors measured the low-frequency (''unclamped'') electrooptic and piezoelectric coefficients in undoped BaTiO/sub 3/ and Sr/sub x/Ba/sub 1-x/Nb/sub 2/O/sub 6/ (chi - 0.61) crystals using interferometric techniques. The contribution of the piezoelectric effect to the Pockels measurement is discussed. For an applied ac electric field in the range 0.1-200 V/cm, the electrooptic and piezoelectric effects are linear in the magnitude of of the applied field and independent of its frequency in the range of 10 Hz-100 kHz. The unclamped electrooptic coefficients of poled BaTiO/sub 3/ single crystals are r/sub 13/ = 19.5 +- 1 pm/V and r/sub 33/ = 97 +- 7 pm/V, and for strontium barium niobate are r/sub 13/ = 47 +- 5 pm/V and r/sub 33/ = 235 +- 21 pm/V, all measured at a wavelength of 514.5 nm and at T = 23 0 C. For the barium titanate samples the measured Pockels coefficient r/sub c/ identical to r/sub 33/ - (n/sub 1//n/sub 3/)/sup 3/r/sub 13/ = 79 +- 6 pm/V in good agreement with the value r/sub c/ = 76 +- 7 pm/V computed from the above values of r/sub 13/ and r/sub 33/, where n/sub 1/ and n/sub 3/ are the ordinary and extraordinary indexes of refraction, respectively. The measured piezoelectric coefficient is d/sub 23/ = +28.7 +- 2 pm/V for barium titanate, and is d/sub 23/ = +24.6 +- 2 pm/V for strontium barium niobate. They also measured the photoreflective coupling of two optical beams in the crystals, and they show that the dependence of the coupling strength on beam polarization is in fair agreement with the measured values of the Pockels coefficients

  19. Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.

    Science.gov (United States)

    Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu

    2018-03-13

    Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values

  20. The significance of demonstrating areae gastricae at hypotonic double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Rienmueller, R.

    1980-01-01

    150 patients were examined by the double contrast-technique in drug-induced hypotonia of the stomach. They were examined gastroscopically and at the same time biopsies were taken. Comparison of histological and radiological results was performed. There was found an agreement of 82% in the performance of areae gastricae and the histological diagnosis of chronic gastritis. (orig.) [de

  1. Complementary contrast media for metal artifact reduction in dual-energy computed tomography.

    Science.gov (United States)

    Lambert, Jack W; Edic, Peter M; FitzGerald, Paul F; Torres, Andrew S; Yeh, Benjamin M

    2015-07-01

    Metal artifacts have been a problem associated with computed tomography (CT) since its introduction. Recent techniques to mitigate this problem have included utilization of high-energy (keV) virtual monochromatic spectral (VMS) images, produced via dual-energy CT (DECT). A problem with these high-keV images is that contrast enhancement provided by all commercially available contrast media is severely reduced. Contrast agents based on higher atomic number elements can maintain contrast at the higher energy levels where artifacts are reduced. This study evaluated three such candidate elements: bismuth, tantalum, and tungsten, as well as two conventional contrast elements: iodine and barium. A water-based phantom with vials containing these five elements in solution, as well as different artifact-producing metal structures, was scanned with a DECT scanner capable of rapid operating voltage switching. In the VMS datasets, substantial reductions in the contrast were observed for iodine and barium, which suffered from contrast reductions of 97% and 91%, respectively, at 140 versus 40 keV. In comparison under the same conditions, the candidate agents demonstrated contrast enhancement reductions of only 20%, 29%, and 32% for tungsten, tantalum, and bismuth, respectively. At 140 versus 40 keV, metal artifact severity was reduced by 57% to 85% depending on the phantom configuration.

  2. Barium and radium migration in unconsolidated Canadian geological materials

    International Nuclear Information System (INIS)

    Gillham, R.W.; Sharma, H.D.; Reddy, M.R.; Cooper, E.L.; Cherry, J.A.

    1981-05-01

    This report describes the results of laboratory studies on the distribution coefficients of radium and barium in samples of unconsolidated geologic materials. Graphs of Ksub(d) versus solution concentration for the respective elements showed constant Ksub(d) values in the low concentration range suggesting that, at low concentrations, a distribution coefficient is a valid means of representing the geochemical reactions of both barium and radium. The Ksub(d) values for barium range between 60 and 3500 ml/g. The values appear to be influenced by the amount of barium occurring naturally in the soil materials and thus there is little possiblility of using barium as an analog of radium in laboratory experiments. The Ksub(d) values of radium vary from 50 to 1000 ml/g indicating that a wide range of geological materials have a substantial capacity to retard the migration of radium

  3. Time requirement for barium reduction in intussusception

    International Nuclear Information System (INIS)

    Hwang, Hye Eun; Kim, Seung Ho; Kang, In Young; Park, Byoung Lan; Kim, Byoung Geun

    1988-01-01

    During the period between January 1985 and December 1987, barium reduction was performed in 146 cases of intussusception who were admitted to Kwangju Christian Hospital. The results were as follows: 1. Success rate to the symptom duration is relatively constant. 2. The success rate in infants with severe dehydration was 50% but it was gradually increased in infants with moderate dehydration and in infants with mild dehydration, 83.3% and 100% respectively. 3. The success rate of 12 cases in severely dehydrated infants with positive dissection sign was 16.7%. 4. The success rate of 15 cases in moderately dehydrated infants with positive dissection sign was 66.7%. 5. The average time requirement for barium reduction was 58.3 minutes. No serious complications were noted during barium reduction, except mild vomiting. 6. With above results, it is desirable that barium reduction should be performed according to the patient's physical status and radiologic findings.

  4. Radiation doses to patients undergoing barium meal and barium enema examinations

    International Nuclear Information System (INIS)

    Delichas, M. G.; Hatziioannou, K.; Papanastassiou, E.; Albanopoulou, P.; Chatzi, E.; Sioundas, A.; Psarrakos, K.

    2004-01-01

    The radiation doses received by patients during 41 barium meal (BM) and 42 barium enema (BE) examinations in two Greek hospitals are presented. Radiation dose was measured in terms of the dose area product (DAP). The effective dose and doses to certain organs were estimated using the ODS-60 software. Mean total DAP values were found to be 25 ± 11 Gy cm 2 for BM and 60 ± 35 Gy cm 2 for BE examinations, whereas the estimated mean values of effective dose were 8.6 ± 4.0 and 24 ± 16 mSv respectively. DAP to effective dose conversion coefficients were estimated to be 0.34 mSv per Gy cm 2 for BM and 0.41 mSv per Gy cm 2 for BE. (authors)

  5. Study of grain boundary tunneling in barium-titanate ceramic films

    CERN Document Server

    Wong, H; Poon, M C

    1999-01-01

    The temperature and the electric-field dependences of the current-voltage characteristics and the low-frequency noise of barium-titanate ceramic films are studied. An abnormal field dependence is observed in the resistivity of BaTiO sub 3 materials with a small average grain size. In addition, experiments show that the low-frequency noise behaviors are governed by grain-boundary tunneling at room temperature and by trapping-detrapping of grain-boundary states at temperatures above the Curie point. Physical models for the new observations are developed. Results suggest that grain-boundary tunneling of carriers is as important as the double Schottky barrier in the current conduction in BaTiO sub 3 materials with small grain sizes.

  6. Surface studies of barium and barium oxide on tungsten and its application to understanding the mechanism of operation of an impregnated tungsten cathode

    Science.gov (United States)

    Forman, R.

    1976-01-01

    Surface studies have been made of multilayer and monolayer films of barium and barium oxide on a tungsten substrate. The purpose of the investigation was to synthesize the surface conditions that exist on an activated impregnated tungsten cathode and obtain a better understanding of the mechanism of operation of such cathodes. The techniques employed in these measurements were Auger spectroscopy and work-function measurements. The results of this study show that the surface of an impregnated cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on oxidized tungsten by evaluating Auger spectra and work-function measurements. Data obtained from desorption studies of barium monolayers on a tungsten substrate in conjunction with Auger and work-function results have been interpreted to show that throughout most of its life an impreganated cathode has a partial monolayer, rather than a monolayer, of barium on its surface.

  7. Effects of chemesthetic stimuli mixtures with barium on swallowing apnea duration.

    Science.gov (United States)

    Todd, J Tee; Butler, Susan G; Plonk, Drew P; Grace-Martin, Karen; Pelletier, Cathy A

    2012-10-01

    This study tested the hypotheses that swallowing apnea duration (SAD) will increase given barium versus water, chemesthetic stimuli (i.e., water barium, age (older > younger), and genetic taste differences (supertasters > nontasters). Prospective group design. University Medical Center. Eighty healthy women were identified as nontasters and supertasters, equally comprising two age groups: 18 to 35 years and 60+ years. The KayPentax Swallowing Signals Lab was used to acquire SAD via nasal cannula during individually randomized swallows of 5 mL barium, 2.7% w/v citric acid with barium, carbonation with barium, and 50:50 diluted ethanol with barium. Data were analyzed using path analysis, with the mediator of chemesthetic perception, adjusted for repeated measures. Significant main effects of age (P = .012) and chemesthetic stimuli (P = .014) were found, as well as a significant interaction between chemesthetic stimuli and age (P = .028). Older women had a significantly longer SAD than younger women. Post hoc analyses revealed that barium mixed with ethanol elicited a significantly longer SAD than other bolus conditions, regardless of age group. There were no significant differences in SAD between barium and water conditions, and no significant effect of chemesthetic perception (P > .05). Ethanol added to barium elicited longer SAD compared to plain barium, but not the other chemesthetic conditions. Older women had a longer SAD than younger women in all conditions. These findings may influence design of future studies examining effects of various stimuli on SAD. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  8. Post-mortem computed tomography angiography utilizing barium sulfate to identify microvascular structures : a preliminary phantom model and case study

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Kuster, Lidy; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2016-01-01

    We investigated the use of computer tomography angiography (CTA) to visualize microvascular structures in a vessel-mimicking phantom and post-mortem (PM) bodies. A contrast agent was used based on 22% barium sulfate, 20% polyethylene glycol and 58% distilled water. A vessel-mimicking phantom

  9. Evaluation of roentgenologic study of the stomach

    International Nuclear Information System (INIS)

    Suh, Jung Ho; Choi, Byung So

    1972-01-01

    In order to achieve more correct diagnosis of gastric lesion, further progress in the technique of diagnosis is much desired. And so, in pursuing the more ideal study, about 7,500 cases of U. G. I. studies taken in Severance Hospital in the past 29 months from May 1969 to September 1971, have been reviewed to evaluate how the following factors will affect the demonstrability of gastric lesion in upper G. I. series. (1) Introduction of air into the stomach by nasogastric tube. (2) Kinds and concentration of barium. (3) Demonstrability according to the position of the patient. (4) Use of antispasmodics. The results may be briefly summarized as follows: 1. The intubation of nasogastric tube gives discomfort temporarily to the patient: however, it has an advantage that the amount of air required for ideal insufflation of the stomach can be controlled under the fluoroscopy. 2. About concentration and type of barium. a) Mikabarium in 90% seems to give the best result in filling study, mucosal relief study and double contrast study. b) Mikabarium in higher concentration adheres to the mucosa better, thus resulting in good double contrast: however, it tends to coagulate each other in the high concentration. c) Micropaque powder of 110% solution produces good double contrast, but it has the disadvantage of making air bubbles. d) When water is given prior to barium ingestion, the anterior wall of stomach is better demonstrated with mucosal relief study. e) To get better result in contrast study, the selection of barium is important as well as rapid and proper positioning of the patient and abdominal respiratory movement. 3. Demonstrability of the stomach lesion according to the position. a) The small lesion either in pylorus or in antrum can be best demonstrated by compression technique of double contrast method in supine position. b) The mucosal relief study in prone by adequate air insufflation was proper to demonstrate the lesion of anterior wall. c) In the lesion of the

  10. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    National Research Council Canada - National Science Library

    Roeder, Ryan K

    2008-01-01

    ...) and contrast agents with higher x-ray attenuation than bone. The ability to detect the presence and to a limited extent the morphology of microdamage in cortical and trabecular bone using micro-CT was demonstrated using a barium sulfate (BaSO4) stain...

  11. Modified double contrast-enhanced examination of the stomach of adipose patients after vertical gastroplasty; Modifizierte Doppelkontrast-Untersuchung des Magens bei adipoesen Patienten nach vertikaler Gastroplastie

    Energy Technology Data Exchange (ETDEWEB)

    Raissaki, M.T. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece); Prassopoulos, P. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece); Hatjidakis, A.A. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece); Christodoulakis, M. [Klinik fuer Chirurgische Onkologie der Universitaetsklinik Heraklion (Greece); Melissas, J. [Klinik fuer Chirurgische Onkologie der Universitaetsklinik Heraklion (Greece); Gourtsoyiannis, N.C. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece)

    1995-11-01

    The study reported covers 28 patients who were examined once by radiology before surgery, and twice after surgery. The first post-surgery examination was done on days 5-7, the second during the 4th until 6th month after surgery. For the first examination, water-soluble contrast agent was initially applied, then barium containing contrast agent. The second examination was done by modified double contrast technique. The most frequent, pre-surgery findings revealed gastro-esophageal reflux in 13 patients. The first post-surgery control detected a somastenosis in 2 patients, while the second control examination detected complications of various nature in 11 patients and gastro-esophageal reflux in 5 patients. In 6 patients, discrepancy between clinical and radiological findings was stated. The pouch size did not correlate with the frequency of complications, or with the body-to-mass index decrease. The examination method proposed in this article yields pre-surgery information on the anatomy of the stomach, more accurate dewscription of post-surgery complications, and better evaluation of the antireflux effect of the vertical gastroplasty. (orig.) [Deutsch] In der Studie wurden 28 Patienten einmal praeoperativ und zweimal postoperativ roentgenologisch kontrolliert. Die erste postoperative Kontrolle fand am 5.-7. Tag und die zweite im 4.-6. Monat nach dem Eingriff statt. Bei der ersten Kontrolle wurde zuerst wasserloesliches und anschliessend bariumhaltiges Kontrastmittel benutzt, waehrend bei der zweiten Kontrolle eine modifizierte Doppelkontrast-Untersuchung durchgefuehrt wurde. Der haeufigste praeoperative Befund war der gastrooesophageale Reflux bei 13 Patienten. Bei der ersten praeoperativen Kontrolle fand sich bei 2 Patienten eine Stomastenose, waehrend bei der zweiten verschiedene Komplikationen bei 11 sowie gastrooesophagealer Reflux bei 5 Patienten vorlagen. Eine Diskrepanz zwischen radiologischen und klinischen Befunden fanden wir bei 6 Patienten. Die

  12. Assessing colonic anatomy normal values based on air contrast enemas in children younger than 6 years

    NARCIS (Netherlands)

    Koppen, Ilan J. N.; Yacob, Desale; Di Lorenzo, Carlo; Saps, Miguel; Benninga, Marc A.; Cooper, Jennifer N.; Minneci, Peter C.; Deans, Katherine J.; Bates, D. Gregory; Thompson, Benjamin P.

    2017-01-01

    Contrast enemas with barium or water-soluble contrast agents are sometimes performed in children with severe intractable constipation to identify anatomical abnormalities. However there are no clear definitions for normal colonic size or abnormalities such as colonic dilation or sigmoid redundancy

  13. Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation.

    Science.gov (United States)

    Deinzer, Christoph K W; Danova, Daniela; Kleb, Beate; Klose, Klaus J; Heverhagen, Johannes T

    2014-01-01

    The objective of this work was to examine differences in DNA double-strand break induction in peripheral blood lymphocytes after in vitro X-ray irradiation between iodinated contrast agents. Four different iodinated X-ray contrast agents--three of them with two different iodine concentrations--and mannitol (negative control; concentration of 150 mg mannitol per ml blood) were pipetted into blood samples so that there was a concentration of 0, 7.5 or 15 mg of iodine per ml blood in the samples. Negative controls without contrast medium (0 mg of iodine per ml blood) were also processed for every irradiation dose. The tubes were exposed to 0, 20 or 500 mGy in vitro X-ray irradiation. After that, the lymphocytes were separated by using density-gradient centrifugation. Fluorescence microscopy was applied to determine the average number of γH2AX-foci per lymphocyte in the presence or absence of different contrast media or mannitol. Differences in the number of γH2AX-foci were statistically analysed by one-way ANOVA and post-hoc Tukey's honestly significant difference test. Iodinated contrast agents led to a statistically significant increase in DNA double-strand breaks after in vitro irradiation. This effect increased statistically significant with rising radiation dose and appeared independent of the contrast agent used (iopromid, iodixanol, iomeprol, iopamidol). A statistically significant difference in DNA damage between the different tested contrast agents was not found. Therefore, the increase in DNA double-strand breaks depends solely on the amount of iodine applied. For evaluation of clinical consequences, our findings could be tested in further animal studies. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Regeneration of barium carbonate from barium sulphide in a pilot-scale bubbling column reactor and utilization for acid mine drainage

    CSIR Research Space (South Africa)

    Mulopo, J

    2012-01-01

    Full Text Available Batch regeneration of barium carbonate (BaCO3) from barium sulphide (BaS) slurries by passing CO2 gas into a pilot-scale bubbling column reactor under ambient conditions was used to assess the technical feasibility of BaCO3 recovery in the Alkali...

  15. Use of carbon dioxide as an intravascular contrast agent: A review of current literature

    OpenAIRE

    Ali, Fahad; Mangi, Muhammad Asif; Rehman, Hiba; Kaluski, Edo

    2017-01-01

    Use of X-ray contrast allows us to differentiate between two or more adjacent structures on radiographic studies. The X-ray contrast agent can be the one with increase X-ray absorption, like iodine and a barium X-ray contrast agent or the one with decrease X-ray absorption like air and carbon dioxide contrast agent. Each contrast agent possesses different risks and benefits in various ways. Carbon dioxide as an intravascular contrast agent can be used as an alternative intravascular contrast ...

  16. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished liver...

  17. Influence of barium sulfate X-ray imaging contrast material on properties of floating drug delivery tablets.

    Science.gov (United States)

    Diós, Péter; Szigeti, Krisztián; Budán, Ferenc; Pócsik, Márta; Veres, Dániel S; Máthé, Domokos; Pál, Szilárd; Dévay, Attila; Nagy, Sándor

    2016-12-01

    The objective of the study was to reveal the influence of necessarily added barium sulfate (BaSO 4 ) X-ray contrast material on floating drug delivery tablets. Based on literature survey, a chosen floating tablet composition was determined containing HPMC and carbopol 943P as matrix polymers. One-factor factorial design with five levels was created for evaluation of BaSO 4 (X 1 ) effects on experimental parameters of tablets including: floating lag time, total floating time, swelling-, erosion-, dissolution-, release kinetics parameters and X-ray detected volume changes of tablets. Applied concentrations of BaSO 4 were between 0 and 20.0% resulting in remarkable alteration of experimental parameters related especially to flotation. Drastic deterioration of floating lag time and total floating time could be observed above 15.0% BaSO 4 . Furthermore, BaSO 4 showed to increase the integrity of tablet matrix by reducing eroding properties. A novel evaluation of dissolutions from floating drug delivery systems was introduced, which could assess the quantity of drug dissolved from dosage form in floating state. In the cases of tablets containing 20.0% BaSO 4 , only the 40% of total API amount could be dissolved in floating state. In vitro fine resolution X-ray CT imagings were performed to study the volume change and the voxel distributions as a function of HU attenuations by histogram analysis of the images. X-ray detected relative volume change results did not show significant difference between samples. After 24h, all tablets containing BaSO 4 could be segmented, which highlighted the fact that enough BaSO 4 remained in the tablets for their identification. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  19. Evaluation of barium hydroxide treatment efficacy on a dolomitic marble.

    Science.gov (United States)

    Toniolo, L; Colombo, C; Realini, M; Peraio, A; Positano, M

    2001-01-01

    The Arch of Peace, by Luigi Cagnola, is one of the most famous neoclassical monuments in Milan. It has been subjected to conservative intervention in 1998. In the present paper the efficacy of the consolidation by means of barium hydroxide has been evaluated. The stone material showed severe degradation phenomena as: erosion, pulverisation, exfoliation. The analytical data acquired through X-ray diffraction (XRD), infrared spectrophotometry (FTIR) and scanning electron microscopy (SEM-EDX), allowed to compare the conditions of stone before and after the treatment with barium hydroxide. The presence of barium has been put in evidence mainly on the surface as barium sulphate, whereas barium is only sporadically present within the thickness of the decayed material. The treatment was judged not satisfying and its inefficacy is, most probably, due to a not suitable cleaning procedure carried out before the consolidation.

  20. Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy

    International Nuclear Information System (INIS)

    Panebianco, Valeria; Anzidei, Michele; Catalano, Carlo; Passariello, Roberto; Habib, Fortunee I.; Tomei, Ernesto; Paolantonio, Pasquale; Laghi, Andrea

    2006-01-01

    The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results. (orig.)

  1. Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Panebianco, Valeria; Anzidei, Michele; Catalano, Carlo; Passariello, Roberto [University of Rome ' ' La Sapienza' ' , Department of Radiological Sciences, Rome (Italy); Habib, Fortunee I.; Tomei, Ernesto [University of Rome ' ' La Sapienza' ' , Division of Gastroenterology, Rome (Italy); Paolantonio, Pasquale; Laghi, Andrea [University of Rome ' ' La Sapienza' ' , Department of Radiological Sciences - Polo Didattico Pontino I.C.O.T, Rome (Italy)

    2006-09-15

    The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results. (orig.)

  2. Double-contrast imaging of the pharynx in case of dysphagia as the leading symptom

    International Nuclear Information System (INIS)

    Feyerabend, T.; Schmitt, R.; Richter, E.; Bohndorf, W.

    1989-01-01

    The article explains the value of double-contrast pharyngography in the gradual programme of diagnostic means for clarifying the symptom of dysphagia. The method is simple and quick and well suited as a first screening method before more complicated methods are used. It allows reliable assessment of postoperative or postradiogenic morphology in case of malignant oro- or hypopharynx tumors and thus also is suitable for tumor aftercare programmes. (orig./GDG) [de

  3. SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS

    Science.gov (United States)

    Tompkins, E.R.

    1959-02-24

    The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.

  4. The diagnostic value of barium enema in acute appendicitis

    International Nuclear Information System (INIS)

    Kim, Yong Ga; Chung, Duck Soo; Kim, Ok Dong

    1986-01-01

    Acute appendicitis is the most common acute surgical condition of the abdomen. When the clinical presentation is atypical, barium enema has proven to be safe and useful in confirming the diagnosis and reducing the negative surgical exploration. However, the performance of barium enema in acute appendicitis has known contraindication primarily because of fear of leakage by perforation of the inflamed appendix. This study using barium enema as a diagnostic aid in acute appendicitis with atypical clinical presentation was performed to further support the previously noted efficacy and safety of this procedure. The results were as followings: 1. In case of acute appendicitis with atypical clinical presentation, the use of barium enema as a diagnostic aid increased the accuracy of diagnosis and decreased the negative surgical exploration. In women between 11 to 50 years old age, especially, it played important role differentiating appendicitis from nonsurgical acute abdomen. 2. The results of the study were 92.31% in sensitivity, 7.69% in false positive, 6.9% in false negative, and 10.26% in negative appendectomy. 3. None of case of leakage of barium by perforation of the inflamed appendix was noted, therefore, barium enema was thought to be safe as a diagnostic aid in acute appendicitis. 4. A simple partial or non filling of appendix without other associated positive finding could not exclude appendicitis, therefore, close clinical observation was necessary. 5. The positive findings of barium enema and their sensitivity were as followings: 1. Non filling of appendix: 90% 2. Partial filling of appendix: 91.7% 3. Displacement or a local impression on terminal ileum: 100%

  5. Prompt striations observed in a barium thermite release at 335 km

    International Nuclear Information System (INIS)

    Simons, D.J.; Pongratz, M.B.; Smith, G.M.; Barasch, G.E.; Fitzgerald, T.J.

    1981-01-01

    Three barium clouds have been released from a single rocket at altitudes of 335, 443, and 535 km. The releases were by means of barium thermite injection. Adding the different cross-field velocity components of the rocket at each of the releases resulted in barium clouds with different kinetic velocity distributions. The barium cloud with the most peaked velocity distribution striated promptly, in good agreement with theoretical predictions based on a kinetic plasma instability. Details of the data analysis and experiment are discussed

  6. Double-contrast arthrography in recurrent dislocation of the shoulder

    International Nuclear Information System (INIS)

    Faletti, C.; Vassoney, P.F.; Indemini, E.; Clerico, P.

    1988-01-01

    One hundred and ninety-three shoulder arthrographies were performed between 1979 and 1985 on patients affected by recurrent dislocations. The diagnostic doubt was cleared up in 162 cases (83%). Athrographic diagnosis was confirmed by pathological findings in 92% of the patients who underwent surgery. The double-contrast technique under local anaesthesia with anterior access is suggested, since it allows several arthrograms in different projections. Thus, an analytic study of the articular damage can be carried out. The patterns of each projection are briefly shown. Revision of case histories points out that: a) the use of arthrography should always be assessed on a clinical-radiological basis for each patients; b) there is no doubt as to the usefulness of this examination as a direct means of exploration, as far as the articular damage is concerned, not only as an aid to future surgery, but also in the follow-up of the results of the treatment in the long run

  7. The impact of digital imaging on patient doses during barium studies

    International Nuclear Information System (INIS)

    Broadhead, D.A.; Chapple, C.-L.; Faulkner, K.

    1995-01-01

    Barium studies performed on 10 digital and four non-digital fluoroscopic systems were monitored with dose-area product meters as part of a Regional Patient Dosimetry Audit programme. The data have been collected using a computer to read and reset the dose-area product meter and also to collect patient and examination details. A comparison of dose-area product measurements from digital and non-digital fluoroscopy units on over 10 000 barium studies is presented. The data have been corrected according to patient size. The mean size corrected dose-area product for a barium meal examination was found to be 7.62 Gy cm -2 for a digital set compared with 15.45 Gy cm -2 for a non-digital set with 2462 and 1308 patients included in each measurement series, respectively. Dose-area products were also a factor of approximately two lower for barium enema, barium swallow and barium follow-through examinations performed on digital systems. (author)

  8. Exposure to low-dose barium by drinking water causes hearing loss in mice.

    Science.gov (United States)

    Ohgami, Nobutaka; Hori, Sohjiro; Ohgami, Kyoko; Tamura, Haruka; Tsuzuki, Toyonori; Ohnuma, Shoko; Kato, Masashi

    2012-10-01

    We continuously ingest barium as a general element by drinking water and foods in our daily life. Exposure to high-dose barium (>100mg/kg/day) has been shown to cause physiological impairments. Direct administration of barium to inner ears by vascular perfusion has been shown to cause physiological impairments in inner ears. However, the toxic influence of oral exposure to low-dose barium on hearing levels has not been clarified in vivo. We analyzed the toxic influence of oral exposure to low-dose barium on hearing levels and inner ears in mice. We orally administered barium at low doses of 0.14 and 1.4 mg/kg/day to wild-type ICR mice by drinking water. The doses are equivalent to and 10-fold higher than the limit level (0.7 mg/l) of WHO health-based guidelines for drinking water, respectively. After 2-week exposure, hearing levels were measured by auditory brain stem responses and inner ears were morphologically analyzed. After 2-month exposure, tissue distribution of barium was measured by inductively coupled plasma mass spectrometry. Low-dose barium in drinking water caused severe hearing loss in mice. Inner ears including inner and outer hair cells, stria vascularis and spiral ganglion neurons showed severe degeneration. The Barium-administered group showed significantly higher levels of barium in inner ears than those in the control group, while barium levels in bone did not show a significant difference between the two groups. Barium levels in other tissues including the cerebrum, cerebellum, heart, liver and kidney were undetectably low in both groups. Our results demonstrate for the first time that low-dose barium administered by drinking water specifically distributes to inner ears resulting in severe ototoxicity with degeneration of inner ears in mice. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Barium Titanate Nanoparticles for Biomarker Applications

    International Nuclear Information System (INIS)

    Matar, O; Hondow, N S; Brydson, R M D; Milne, S J; Brown, A P; Posada, O M; Wälti, C; Saunders, M; Murray, C A

    2015-01-01

    A tetragonal crystal structure is required for barium titanate nanoparticles to exhibit the nonlinear optical effect of second harmonic light generation (SHG) for use as a biomarker when illuminated by a near-infrared source. Here we use synchrotron XRD to elucidate the tetragonal phase of commercially purchased tetragonal, cubic and hydrothermally prepared barium titanate (BaTiO 3 ) nanoparticles by peak fitting with reference patterns. The local phase of individual nanoparticles is determined by STEM electron energy loss spectroscopy (EELS), measuring the core-loss O K-edge and the Ti L 3 -edge energy separation of the t 2g , e g peaks. The results show a change in energy separation between the t 2g and e g peak from the surface and core of the particles, suggesting an intraparticle phase mixture of the barium titanate nanoparticles. HAADF-STEM and bright field TEM-EDX show cellular uptake of the hydrothermally prepared BaTiO 3 nanoparticles, highlighting the potential for application as biomarkers. (paper)

  10. Neutral barium cloud evolution at different altitudes

    International Nuclear Information System (INIS)

    Li Lei; Xu Ronglan

    2002-01-01

    Considering the joint effects of diffusion, collision, oxidation and photoionization, the authors study the evolution of the barium cloud at different altitudes in the space plasma active experiment. The results present the variation of the loss rate, number density distribution and brightness of the barium cloud over the range from 120 to 260 km. This can be divided into oxidation, oxidation plus photoionization and photoionization regions

  11. Fabrication and properties of yttrium doped barium titanate film by RF sputtering

    International Nuclear Information System (INIS)

    Igarashi, H.; Yuasa, M.; Okazaki, K.

    1985-01-01

    Semiconductive barium titanate films were fabricated by RF sputtering on fused quartz, alumina and barium titanate ceramic substrates using barium titanate ceramic with a small amount of yttria as a target. The films on the barium titanate substrates turned blue color and showed a small PTC effect by heat-treating at 1000 0 C in the air after deposition at the substrate temperature of 600 0 C

  12. Barium and Tc-poor S stars: Binary masqueraders among carbon stars

    OpenAIRE

    Jorissen, A.; Van Eck, S.

    1997-01-01

    The current understanding of the origin of barium and S stars is reviewed, based on new orbital elements and binary frequencies. The following questions are addressed: (i) Is binarity a necessary condition to produce a barium star? (ii) What is the mass transfer mode (wind accretion or RLOF?) responsible for their formation? (iii) Do barium stars form as dwarfs or as giants? (iv) Do barium stars evolve into Tc-poor S stars? (v) What is the relative frequency of Tc-rich and Tc-poor S stars?

  13. Freeze cast porous barium titanate for enhanced piezoelectric energy harvesting

    Science.gov (United States)

    Roscow, J. I.; Zhang, Y.; Kraśny, M. J.; Lewis, R. W. C.; Taylor, J.; Bowen, C. R.

    2018-06-01

    Energy harvesting is an important developing technology for a new generation of self-powered sensor networks. This paper demonstrates the significant improvement in the piezoelectric energy harvesting performance of barium titanate by forming highly aligned porosity using freeze casting. Firstly, a finite element model demonstrating the effect of pore morphology and angle with respect to poling field on the poling behaviour of porous ferroelectrics was developed. A second model was then developed to understand the influence of microstructure-property relationships on the poling behaviour of porous freeze cast ferroelectric materials and their resultant piezoelectric and energy harvesting properties. To compare with model predictions, porous barium titanate was fabricated using freeze casting to form highly aligned microstructures with excellent longitudinal piezoelectric strain coefficients, d 33. The freeze cast barium titanate with 45 vol.% porosity had a d 33  =  134.5 pC N‑1 compared to d 33  =  144.5 pC N‑1 for dense barium titanate. The d 33 coefficients of the freeze cast materials were also higher than materials with uniformly distributed spherical porosity due to improved poling of the aligned microstructures, as predicted by the models. Both model and experimental data indicated that introducing porosity provides a large reduction in the permittivity () of barium titanate, which leads to a substantial increase in energy harvesting figure of merit, , with a maximum of 3.79 pm2 N‑1 for barium titanate with 45 vol.% porosity, compared to only 1.40 pm2 N‑1 for dense barium titanate. Dense and porous barium titanate materials were then used to harvest energy from a mechanical excitation by rectification and storage of the piezoelectric charge on a capacitor. The porous barium titanate charged the capacitor to a voltage of 234 mV compared to 96 mV for the dense material, indicating a 2.4-fold increase that was similar to that

  14. Synthesis of 14C and 32P double labelled triethylphosphine

    International Nuclear Information System (INIS)

    Kanska, M.; Drabarek, S.

    1979-01-01

    The synthesis of 14 C and 32 P double labelled triethylphosphine has been carried out using red phosphorus [ 32 P] and barium carbonate [ 14 C] as starting materials. The product of the reaction has been separated by gas chromatography. The 32 P radioactivity assay of the obtained product was performed by the liquid scintillation technique. The 14 C radioactivity was determined by the liquid scintillation technique and internal gas counting method. The radioactivity measurements have served to determine the total yield of double labelled triethylphosphine. (author)

  15. Radiation losses in microwave K_u region by conducting pyrrole/barium titanate and barium hexaferrite based nanocomposites

    International Nuclear Information System (INIS)

    Kaur, Talwinder; Kumar, Sachin; Narang, S.B.; Srivastava, A.K.

    2016-01-01

    Nanocomposites of substituted barium hexaferrite and barium titanate embedded in a polymer were synthesized via emulsion polymerization. The study was performed by using X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, electron spin resonance spectroscopy, a vibrating sample magnetometer and a vector network analyzer. It is found that maximum radiation loss occur at 16.09 GHz (−14.23 dB) frequency owing to the combined effect of conducting polymer, suitable dielectric and magnetic material. This suggests that prepared material is suitable for radiation losses. Micro structural study reveals the presence of all the phases of the compounds comprises composite. Benzene ring absorption band (at 1183 cm"−"1) in FT-IR spectra illustrates the presence of polymer. Surface morphology reveals the presence of array of particles encapsulated by the polymer. - Highlights: • Composites having polymer, barium titanate and hexaferrite have been successfully prepared. • Effective radiation absorption and losses have been achieved. • Magnetic properties have made an impact on shielding effectiveness.

  16. Barium uranyl diphosphonates

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Anna-Gay D., E-mail: nelsoa@umich.edu [Department of Civil Engineering and Geological Sciences and Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 (United States); Department of Earth and Environmental Sciences, University of Michigan, Ann Arbor, MI 48109-1005 (United States); Alekseev, Evgeny V. [Institute of Energy and Climate Research (IEK-6), Forschungszentrum Juelich Wilhelm-Johnen-Strasse, Juelich 52428 (Germany); Ewing, Rodney C. [Department of Earth and Environmental Sciences, University of Michigan, Ann Arbor, MI 48109-1005 (United States); Albrecht-Schmitt, Thomas E. [Department of Civil Engineering and Geological Sciences and Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 (United States)

    2012-08-15

    Three Ba{sup 2+}/UO{sub 2}{sup 2+} methylenediphosphonates have been prepared from mild hydrothermal treatment of uranium trioxide, methylendiphosphonic acid (C1P2) with barium hydroxide octahydrate, barium iodate monohydrate, and small aliquots of HF at 200 Degree-Sign C. These compounds, Ba[UO{sub 2}[CH{sub 2}(PO{sub 3}){sub 2}]{center_dot}1.4H{sub 2}O (Ba-1), Ba{sub 3}[(UO{sub 2}){sub 4}(CH{sub 2}(PO{sub 3}){sub 2}){sub 2}F{sub 6}]{center_dot}6H{sub 2}O (Ba-2), and Ba{sub 2}[(UO{sub 2}){sub 2}(CH{sub 2}(PO{sub 3}){sub 2})F{sub 4}]{center_dot}5.75H{sub 2}O (Ba-3) all adopt layered structures based upon linear uranyl groups and disphosphonate molecules. Ba-2 and Ba-3 are similar in that they both have UO{sub 5}F{sub 2} pentagonal bipyramids that are bridged and chelated by the diphosphonate moiety into a two-dimensional zigzag anionic sheet (Ba-2) and a one-dimensional ribbon anionic chain (Ba-3). Ba-1, has a single crystallographically unique uranium metal center where the C1P2 ligand solely bridges to form [UO{sub 2}[CH{sub 2}(PO{sub 3}){sub 2}]{sup 2-} sheets. The interlayer space of the structures is occupied by Ba{sup 2+}, which, along with the fluoride ion, mediates the structure formed and maintains overall charge balance. - Graphical abstract: Illustration of the stacking of the layers in Ba{sub 3}[(UO{sub 2}){sub 4}(CH{sub 2}(PO{sub 3}){sub 2}){sub 2})F{sub 6}]{center_dot}6H{sub 2}O viewed along the c-axis. The structure is constructed from UO{sub 7} pentagonal bipyramidal units, U(1)O{sub 7}=gray, U(2)O{sub 7}=yellow, barium=blue, phosphorus=magenta, fluorine=green, oxygen=red, carbon=black, and hydrogen=light peach. Highlights: Black-Right-Pointing-Pointer The polymerization of the UO{sub 2}{sup 2+} sites to form uranyl dimers leads to structural variations in compounds. Black-Right-Pointing-Pointer Barium cations stitch uranyl diphosphonate anionic layers together, and help mediate structure formation. Black-Right-Pointing-Pointer HF acts as both a

  17. The effect of aspirated barium sulfate, iodixanol, and diatrizoic acid on survival and lung injury in a lagomorph model.

    Science.gov (United States)

    Siddiqui, M Tausif; Litts, Juliana K; Cheney, Diane M; Kuhn, Maggie A; Nativ-Zeltzer, Nogah; Belafsky, Peter C

    2017-05-01

    Contrast agents are an integral component of the video fluoroscopic swallow study. Agents commonly used include barium sulfate (E-Z Paque), iodixanol (Visipaque), and diatrizoic acid (Gastrografin). Barium is water insoluble, whereas iodixanol and diatrizoic acid are water-soluble iodine-based agents. The detrimental effect of these agents on the lungs has not been systematically evaluated. Our aim was to evaluate and compare the effects of aspirated barium, iodixanol, and diatrizoic acid on pulmonary injury in a lagomorph model. Animal model. Twenty adult male New Zealand White rabbits were divided into four groups (n = 5). Group 1 received 3 mL of barium sulfate injected into the trachea for 3 consecutive days. Group 2 received 3 mL of iodixanol injected into the trachea for 3 consecutive days. Group 3 received 3 mL of diatrizoic acid injected into the trachea for 3 consecutive days. A control group received 3 mL of air injected into the trachea under an identical protocol. All animals were euthanized on day 4, and the lung and trachea were harvested for blinded histopathologic analysis. The primary outcome measure was survival. The secondary endpoint was a blinded, histologic grading system of lung injury. Two animals in the barium group, one in the diatrizoic acid group, and 0 animals in the iodixanol and control groups died. The overall lung injury score for the barium (60.60 ± 6.34) and iodixanol groups (52.30 ± 3.11) were significantly higher (worse) than the diatrizoic acid (49.60 ± 7.64) and control groups (37.80 ± 3.56) (P barium sulfate (E-Z Paque) over 3 consecutive days causes more severe lung injury in a lagomorph model than 3 mL of aspirated iodixanol (Visipaque) and diatrizoic acid (Gastrografin). Diatrizoic acid caused the least histologic evidence of lung injury. NA Laryngoscope, 127:E148-E152, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Fabry-Perot measurements of barium temperature in fluorescent lamps

    International Nuclear Information System (INIS)

    Hadrath, S; Garner, R

    2010-01-01

    A scanning Fabry-Perot interferometer (FPI) is used to determine the temperature of barium atoms that are liberated from the electrodes of fluorescent lamps during their steady-state operation. Barium, a constituent of the work function lowering emitter material that is placed on the tungsten coil that forms the electrode, is liberated primarily by evaporation from the hot (∼1300 K) thermionic electrode. However, there may be situations or modes of operation in which barium is, in addition, sputtered, a condition which may lead to increased end-darkening, shortened life and increased mercury consumption in the lamp. Using the FPI diagnostic, the occurrence of sputtering is inferred when barium temperatures are much greater than the electrode temperature. The FPI diagnostic senses resonance radiation (λ = 553 nm) emitted by barium atoms excited in the low pressure discharge environment, and infers temperature from the Doppler broadened linewidth. The diagnostic has proven to be successful in a number of situations. Measurements have been made on rare gas discharges and on Hg-argon discharges for different discharge currents, gas pressures and auxiliary coil currents. Measurements are phase resolved for ac-driven discharges.

  19. Contrast media. Safety issues and ESUR guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H.S. (ed.) [Copenhagen Univ. Hospital, Herlev (Denmark). Dept. of Diagnostic Radiology 54E2

    2006-07-01

    In 1994 the European Society of Urogenital Radiology (ESUR) set up a committee to consider the safety of the contrast media used in radiology departments. Since then, the committee has questioned members, reviewed the literature, proposed guidelines, and discussed these proposals with participants at the annual symposia on urogenital radiology. This book represents the end result of this hard work. It contains all of the agreed guidelines, updated when necessary, and thereby comprehensively covers the many different safety issues relating to the diverse contrast media: barium contrast media, iodinated contrast media, MR contrast media (both gadolinium-based extracellular and organ-specific) and ultrasound contrast media. The prevention and treatment of both acute and delayed non-renal adverse reactions as well as the renal adverse reactions are covered in detail. The inclusion of all the ESUR guidelines within one book will offer an invaluable, unique and unparalleled resource. (orig.)

  20. Contrast media. Safety issues and ESUR guidelines

    International Nuclear Information System (INIS)

    Thomsen, H.S.

    2006-01-01

    In 1994 the European Society of Urogenital Radiology (ESUR) set up a committee to consider the safety of the contrast media used in radiology departments. Since then, the committee has questioned members, reviewed the literature, proposed guidelines, and discussed these proposals with participants at the annual symposia on urogenital radiology. This book represents the end result of this hard work. It contains all of the agreed guidelines, updated when necessary, and thereby comprehensively covers the many different safety issues relating to the diverse contrast media: barium contrast media, iodinated contrast media, MR contrast media (both gadolinium-based extracellular and organ-specific) and ultrasound contrast media. The prevention and treatment of both acute and delayed non-renal adverse reactions as well as the renal adverse reactions are covered in detail. The inclusion of all the ESUR guidelines within one book will offer an invaluable, unique and unparalleled resource. (orig.)

  1. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China); Wang, Guixian, E-mail: guixianwang@hotmail.com [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China)

    2012-09-15

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation.

  2. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    International Nuclear Information System (INIS)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai; Wang, Guixian

    2012-01-01

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation

  3. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1989-08-15

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction.

  4. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    International Nuclear Information System (INIS)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup

    1989-01-01

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction

  5. Effects of detomidine on equine oesophageal function as studied by contrast radiography

    International Nuclear Information System (INIS)

    Watson, T.D.G.; Sullivan, M.

    1991-01-01

    The effects of sedation with detomidine on oesophageal function were assessed by contrast radiography in 10 healthy adult thoroughbred horses. Barium swallows were monitored by means of image intensification, first without sedation and then after the intravenous administration of detomidine at doses of 10 and 20 micrograms/kg bodyweight. The transit time of contrast agent to the oesophageal hiatus was recorded and each swallow was scored for markers of oesophageal dysfunction. Analysis of the data indicated that there were highly significant dose dependent increases in the transit time, the retention of barium within the longitudinal mucosal folds, and retrograde peristalsis and pooling of contrast agent within the oesophagus at both the thoracic inlet and caudal to the base of the heart. The degree of gastrooesophageal reflux was not affected at either dosage. These changes in oesophageal function were similar to those recorded from cases of grass sickness and indicate that care should be taken in the interpretation of studies of swallowing in animals that have been given detomidine before a radiographic examination

  6. Easier to swallow: pictorial review of structural findings of the pharynx at barium pharyngography.

    Science.gov (United States)

    Tao, Ting Y; Menias, Christine O; Herman, Thomas E; McAlister, William H; Balfe, Dennis M

    2013-01-01

    Barium pharyngography remains an important diagnostic tool in the evaluation of patients with dysphagia. Pharyngography can not only help detect functional abnormalities but also help identify a wide spectrum of structural abnormalities in children and adults. These structural abnormalities may reflect malignant or nonmalignant oropharyngeal, hypopharyngeal, or laryngeal processes that deform or alter normal coated mucosal surfaces. Therefore, an understanding of the normal appearance of the pharynx at contrast material-enhanced imaging is necessary for accurate detection and interpretation of abnormal findings. Congenital malformations are more typically identified in the younger population; inflammatory and infiltrative diseases, trauma, foreign bodies, and laryngeal cysts can be seen in all age groups; and Zenker and Killian-Jamieson diverticula tend to occur in the older population. Squamous cell carcinoma is by far the most common malignant process, with contrast-enhanced imaging findings that depend on tumor location and morphology. Treatments of head and neck cancers include total laryngectomy and radiation therapy, both of which alter normal anatomy. Patients are usually evaluated immediately after laryngectomy to detect complications such as fistulas; later, pharyngography is useful for identifying and characterizing strictures. Deviation from the expected posttreatment appearance, such as irregular narrowing or mucosal nodularity, should prompt direct visualization to evaluate for recurrence. Contrast-enhanced imaging of the pharynx is commonly used in patients who present with dysphagia, and radiologists should be familiar with the barium pharyngographic appearance of the normal pharyngeal anatomy and of some of the processes that alter normal anatomy. © RSNA, 2013.

  7. Barium ion beam. Annual progress report

    International Nuclear Information System (INIS)

    Lazar, N.; Dandl, R.; Rynn, N.; Wickham, M.

    1985-01-01

    The barium ion beam Zeeman diagnostic is an in situ nonperturbing diagnostic designed to measure both the plasma electric and magnetic fields in devices such as STM and EBT. The diagnostic satisfies the requirements of high precision, spatial resolution and nonperturbation of the plasma. The technique uses resonance absorption of light from a single moded laser in a beam of energetic barium ions to measure the Zeeman effect in the absorption spectrum (to measure changes in the magnetic field) and to observe the changes in beam velocity by the Doppler shift of the absorption lines

  8. Recurrent Pneumonia due to Double Aortic Arch

    Directory of Open Access Journals (Sweden)

    I. Sedighi

    2012-04-01

    Full Text Available Introduction: Pneumonia is one of the most common infections during childhood. In children with recurrent bacterial pneumonia complete evaluation for underlying factors is necessary. The most common underlying diseases include: antibody deficiencies , cystic fibrosis , tracheoesophageal fistula and increased pulmonary blood flow. Vascular ring and its pressure effect is a less common cause of stridor and recurrent pneumonia. Congenital abnormalities in aortic arch and main branches which form vascular ring around esophagus and trachea with variable pressure effect cause respiratory symptoms such as stridor , wheezing and recurrent pneumoniaCase Report: A 2 year old boy was admitted in our hospital with respiratory distress and cough . Chest x-Ray demonstrated right lobar pneumonia. He had history of stridor and wheezing from neonatal period and hospitalization due to pneumonia for four times. The patient received appropriate antibiotics. Despite fever and respiratory distress improvement, wheezing continued. Review of his medical documents showed fixed pressure effect on posterior aspect of esophagus in barium swallow. In CT angiography we confirmed double aortic arch.Conclusion: Double aortic arch is one of the causes of persistant respiratory symptom and recurrent pneumonia in children for which fluoroscopic barium swallow is the first non-invasive diagnostic method.(Sci J Hamadan Univ Med Sci 2012;19(1:70-74

  9. Characterization of Barium Borate Frameworks Using Raman Spectroscopy.

    Science.gov (United States)

    Gharavi-Naeini, Jafar; Yoo, Kyung W; Stump, Nathan A

    2018-04-01

    Systematic micro-Raman scattering investigations have been carried out on Sm +2 doped 2(BaO)-n(B 2 O 3 ) matrices for n = 4, 5, 8, and 2(BaO)-(Na 2 O)-9(B 2 O 3 ) using the 364 nm excitation of an Ar + laser. The Raman results have been compared with the known structures of barium tetraborate, barium pentaborate, barium octaborate, and barium sodium nonaborate. An excellent correlation has been found between the BO 4 /BO 3 composition ratios for each product and intensity ratios of the designated BO 4 and BO 3 Raman peaks. Furthermore, the Raman frequencies of both BO 4 and BO 3 groups undergo a systematic blueshift as n increases from four to nine. The shift results from a decrease of the B-O bond lengths for both BO 4 and BO 3 groups as the samples transition from the tetraborate to nonaborate structures. Linear relations (with negative slopes) have been determined between the measured Raman frequencies and B-O bond lengths in the frameworks.

  10. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00...

  11. Double blind evaluation of the effects of various contrast media on extremity veins in the dog

    International Nuclear Information System (INIS)

    Laerum, F.; Dehner, L.P.; Rysavy, J.; Amplatz, K.; Minnesota Univ., Minneapolis

    1987-01-01

    Canine superficial extremity veins were examined grossly and microscopically in a double blind fashion for endothelial damage and phlebitis one hour and four days after the injection of ionic monomeric or dimeric, and non-ionic monomeric, 300 mg I/ml, contrast media. Superficial veins of all four extremities and the tail vein were injected with the same amounts of contrast medium after application of tourniquets for 20 minutes following the injections. Silver staining and prefixation of the veins were done in situ. The specimens were evaluated together with cross-sectioned, hematoxylin-eosin stained biopsies. On the basis of a randomized study of 77 dogs, endothelial damage or thrombosis caused by various contrast media as seen in man was not demonstrated. This may be due to species differences. It is postulated that canine endothelium may have a higher resistance to contrast medium injury than human endothelium. (orig.)

  12. Radiation losses in microwave K{sub u} region by conducting pyrrole/barium titanate and barium hexaferrite based nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Talwinder [Department of Physics, Lovely Professional University, Phagwara 144411 (India); Kumar, Sachin [Department of Chemistry, Guru Nanak Dev University, Amritsar 143005 (India); Narang, S.B. [Department of Electronics Technology, Guru Nanak Dev University, Amritsar 143005 (India); Srivastava, A.K., E-mail: srivastava_phy@yahoo.co.in [Department of Physics, Lovely Professional University, Phagwara 144411 (India)

    2016-12-15

    Nanocomposites of substituted barium hexaferrite and barium titanate embedded in a polymer were synthesized via emulsion polymerization. The study was performed by using X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, electron spin resonance spectroscopy, a vibrating sample magnetometer and a vector network analyzer. It is found that maximum radiation loss occur at 16.09 GHz (−14.23 dB) frequency owing to the combined effect of conducting polymer, suitable dielectric and magnetic material. This suggests that prepared material is suitable for radiation losses. Micro structural study reveals the presence of all the phases of the compounds comprises composite. Benzene ring absorption band (at 1183 cm{sup −1}) in FT-IR spectra illustrates the presence of polymer. Surface morphology reveals the presence of array of particles encapsulated by the polymer. - Highlights: • Composites having polymer, barium titanate and hexaferrite have been successfully prepared. • Effective radiation absorption and losses have been achieved. • Magnetic properties have made an impact on shielding effectiveness.

  13. Radium-226 and barium as tracers of water masses in the North Atlantic (GA01-GEOTRACES)

    Science.gov (United States)

    Le Roy, Emilie; Sanial, Virginie; Charette, Matthew; Henderson, Paul; Jacquet, Stéphanie; García-Ibáñez, Maribel; Pérez, Fiz; Lherminer, Pascale; Souhaut, Marc; Jeandel, Catherine; Lacan, François; van Beek, Pieter

    2017-04-01

    In this study, we report concentrations of radium-226 (226Ra, t1/2=1602 y) and barium determined along the GEOVIDE section conducted in the North Atlantic (May-July 2014; Portugal-Greenland-Canda) in the framework of the international GEOTRACES program. A high vertical resolution (up to 22 depths per station) was achieved by analyzing small volumes (˜10 L) of seawater for 226Ra using a radon emanation technique. We will present the distribution of 226Ra activities and barium concentrations in contrasting biogeochemical regions of the North Atlantic (Iberian margin, West European Basin, Reykjanes Ridge, Irminger Sea, Greenland margin and Labrador Sea). These regions strongly differ in terms of boundary inputs, biogeochemistry and deep water formation. We observe a linear correlation between 226Ra and barium along the GEOVIDE section, which results from the dominantly conservative behavior of the two tracers. However, deviations from the linear correlation between 226Ra and Ba are found in several places. The potential causes for such deviations are investigated. Optimum multi-parameter (OMP) analysis was thus used to distinguish the relative importance of physical transport (i.e., water mass mixing) from non-conservative processes (sedimentary, river or hydrothermal inputs; uptake by particles) on the 226Ra and Ba distribution in the North Atlantic.

  14. Preparation of porous nano barium ferrite and its adsorption properties on uranium

    International Nuclear Information System (INIS)

    Xiong Guoxuan; Huang Haiqing; Zhang Zhibin

    2012-01-01

    The porous nano barium ferrite was made of Fe(NO 3 ) 3 and Ba(NO 3 ) 2 as raw materials, CTAB as surfactant by method of sol-gel and self-propagating combustion. The composition, morphology and magnetic properties of nano-rod barium ferrite were characterized by XRD, SEM and vibrating sample magnetometer. The adsorption properties of porous nano barium ferrite on uranium were studied with static adsorption and the effects of pH, adsorption temperature and oscillation time on adsorption properties were discussed. The results indicate that the average particle size of porous nano barium ferrite is 45-65 nm, the saturation magnetization and coercivity are 62.83 emu/g and 5481.0 Oe, respectively. Under the condition of the porous nano barium ferrite amount of 0.02 g, pH of 6, adsorption temperature of 25℃ and oscillation time of 30 min, the adsorption capacity of uranium on the porous nano barium ferrite reaches 921 μg/g. (authors)

  15. A review of the health impacts of barium from natural and anthropogenic exposure.

    Science.gov (United States)

    Kravchenko, Julia; Darrah, Thomas H; Miller, Richard K; Lyerly, H Kim; Vengosh, Avner

    2014-08-01

    There is an increasing public awareness of the relatively new and expanded industrial barium uses which are potential sources of human exposure (e.g., a shale gas development that causes an increased awareness of environmental exposures to barium). However, absorption of barium in exposed humans and a full spectrum of its health effects, especially among chronically exposed to moderate and low doses of barium populations, remain unclear. We suggest a systematic literature review (from 1875 to 2014) on environmental distribution of barium, its bioaccumulation, and potential and proven health impacts (in animal models and humans) to provide the information that can be used for optimization of future experimental and epidemiological studies and developing of mitigative and preventive strategies to minimize negative health effects in exposed populations. The potential health effects of barium exposure are largely based on animal studies, while epidemiological data for humans, specifically for chronic low-level exposures, are sparse. The reported health effects include cardiovascular and kidney diseases, metabolic, neurological, and mental disorders. Age, race, dietary patterns, behavioral risks (e.g., smoking), use of medications (those that interfere with absorbed barium in human organism), and specific physiological status (e.g., pregnancy) can modify barium effects on human health. Identifying, evaluating, and predicting the health effects of chronic low-level and moderate-level barium exposures in humans is challenging: Future research is needed to develop an understanding of barium bioaccumulation in order to mitigate its potential health impacts in various exposured populations. Further, while occupationally exposed at-risk populations exist, it is also important to identify potentially vulnerable subgroups among non-occupationally exposed populations (e.g., elderly, pregnant women, children) who are at higher risk of barium exposure from drinking water and food.

  16. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms.

    Science.gov (United States)

    Saleh, C M G; Smout, A J P M; Bredenoord, A J

    2015-02-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20 subjects with reflux symptoms. pH-impedance measurements were used as gold standard for the diagnosis of GERD. Gastro-esophageal reflux measured with the barium study was defined as a positive outcome. 50% of patients presented gastro-esophageal reflux on the barium esophagogram. No significant differences were observed in acid exposure time between subjects with (median: 7.4%; interquartile range, IQR: 8.4%) or without reflux at barium esophagography (median: 5.95%; IQR: 13.05%; p > 0.05). Nor did we find differences in median proximal extent of reflux measured with impedance monitoring between patients with a positive (median: 6.7%; IQR: 1.95%) and negative barium study (median: 7.1%; IQR: 0.68%; p > 0.05). Patients with reflux on barium esophagogram did not have a positive symptom association probability more often than those who did not have reflux at barium esophagography. Lastly, there were no differences in numbers of acid, weakly acidic or total reflux episodes between those with positive or negative barium esophagogram (p > 0.05). No correlations were found between the maximum proximal extent of gastro-esophageal reflux during esophagography and pH-impedance parameters. Presence or absence of gastro-esophageal reflux during barium esophagography does not correlate with incidence or extent of reflux observed during 24-h pH-impedance monitoring and is not of value for the diagnosis of GERD. © 2014 John Wiley & Sons Ltd.

  17. Application of magnesium hydroxide and barium hydroxide for the ...

    African Journals Online (AJOL)

    Application of magnesium hydroxide and barium hydroxide for the removal of metals and sulphate from mine water. ... equivalent to the Ba(OH)2 dosage. During CO2-dosing, CaCO3 is precipitated to the saturation level of CaCO3. Keywords: Magnesium hydroxide; barium hydroxide; sulphate removal; water treatment ...

  18. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Barium azide-50 percent or more water wet. 173.182 Section 173.182 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more...

  19. Barium-borate-flyash glasses: As radiation shielding materials

    International Nuclear Information System (INIS)

    Singh, Sukhpal; Kumar, Ashok; Singh, Devinder; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The attenuation coefficients of barium-borate-flyash glasses have been measured for γ-ray photon energies of 356, 662, 1173 and 1332 keV using narrow beam transmission geometry. The photon beam was highly collimated and overall scatter acceptance angle was less than 3 o . Our results have an uncertainty of less than 3%. These coefficients were then used to obtain the values of mean free path (mfp), effective atomic number and electron density. Good agreements have been observed between experimental and theoretical values of these parameters. From the studies of the obtained results it is reported here that from the shielding point of view the barium-borate-flyash glasses are better shields to γ-radiations in comparison to the standard radiation shielding concretes and also to the ordinary barium-borate glasses

  20. Charge distributions of barium isotopes from muonic X-rays

    International Nuclear Information System (INIS)

    Shera, E.B.; Wohlfahrt, H.D.; Hoehn, M.V.; Tanaka, Y.

    1982-01-01

    The results of a muonic X-ray study of the charge radii of stable barium isotopes are presented and compared with optical isotope shifts. The isotope shifts Δ 2 > of a wide range of barium isotopes are found to be in good agreement with the droplet model and with IBA calculations. (orig.)

  1. BARIUM REDUCTION OF INTUSSUSCEPTION IN INFANCY

    Science.gov (United States)

    Denenholz, Edward J.; Feher, George. S.

    1955-01-01

    Barium enema reduction was used as the initial routine treatment in 29 infants with intussusception. In 22 of them the intussusception was reduced by this means. In three of eight patients operated upon the intussusception was found to be reduced. Four of the remaining five patients had clinical or x-ray evidence of complications before reduction by barium enema was attempted. Twenty-one of the patients, all of whom were observed in private practice, were treated without admission to the hospital. After reduction, these patients were observed closely by the clinician. None of these patients showed clinical or x-ray signs of complications before reduction. Certain clinical and roentgen criteria must be satisfied before it can be concluded that reduction by barium enema is complete. If there are clinical signs of complications with x-ray evidence of small bowel obstruction, only a very cautious attempt at hydrostatic reduction should be made. As the time factor is generally a reliable clinical guide to reducibility, the late cases should be viewed with greater caution. Long duration of symptoms, however, is not per se a contraindication to an attempt at hydrostatic reduction. PMID:13230908

  2. Making of Magnet Barium Ferit Anisotropic

    International Nuclear Information System (INIS)

    Idayati, Novrita; Dedi

    2003-01-01

    Barium Hexa ferrite (BaFe 12 O 19 ) is ceramic and materials which usually used for making of permanent magnet. In this research Barium Hexa ferrite were made Anisotropic, and applied for loudspeaker, electro motors, dynamo, KWh metre, etc. this Magnet is commonly used due to its high Induction of Remanen (Br) and coercivity (high Hc). Besides it applies a more simple and easier process technology, cheaper raw material, and easy to find it, hence the magnetic component is much cheaper. Powder Metallurgy was used for the process technology, by reacting all materials in the powder (oxide), with a certain size distribution and a tight preparation step. The next step was mixing ferrite and Barium Carbonate (in the form of oxide), calcination, compaction, cantering and characterisation. The Anisotropic particle effects a high Induce Remanen (Br) and of koersifitas (high Hc). All the process steps will is determine physical and chemical characteristics of the magnet. The best Magnet characteristic of the magnet produced in this research is Induction of Remanen (Br) = 4,27 kg, Coercivity (Hc) = 1,745 kOe, Energy Product max (BHmaks) = 2,31 MGOe

  3. Thermal reactions of some calcium, strontium, and barium chromates

    International Nuclear Information System (INIS)

    Piekarska-Piesse, B.; Gontarz, Z.; Ostrowski, A.; Kucharski, R.

    2000-01-01

    Thermal decomposition of calcium chromates and solid state reactions of barium and strontium chromates(VI) with barium and strontium hydroxides and carbonates, as well as the reduction of chromates by carbon and hydrogen, have been investigated. The mechanisms of individual stages of the thermal decomposition have been proposed on the basis of morphological classification. (author)

  4. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  5. Barium and radium radiopolarography

    International Nuclear Information System (INIS)

    Fourest, B.

    1979-01-01

    Radiopolarography has been applied to the study of two elements (barium and radium) which is difficult by classical polarography because of their strong electropositivity. Various parameters have been considered: nature, concentration and pH of supporting electrolyte. In any case of investigated mediums, the reduction to the metallic state reaction appeared to be reversible. An important variation of the barium half-wave potential E 1/2 with the ionic strength μ of the solution, imposed by LiCl used as supporting electrolyte, has been observed. It gives the possibility to estimate, for μ = 0, E 1/2 (Ba) = - 1.916 V/S.C.E. and E 1/2(Ra) = - 1.852 V/S.C.E. The values of barium and radium half wave potentials, obtained with a good accuracy in LiCl (or LiClO 4 ) 0.1 M medium, have been used to establish the amalgamation energy Δ 2 (M) of these elements. A linear variation of Δ 2 (M) with the metallic radius of the 2a elements has been obtained. On the other hand, by making the concentration of the complex forming agent (Cit 3- ) vary in the solution, we have a shift in the half wave potential from which we can deduce the stability constant of the complexe and its composition (BaCit - ; pK 1 =2). At last, nature and concentration of the supporting electrolyte (between 5.10 -2 M and 5M) have a determining influence on the extent of the polarogram plateau. This plateau is limited by an 'hollow effect' preceding the supporting electrolyte discharge. An interpretation of this effect is suggested which is based on the Stern model [fr

  6. Radiological demonstration of gastroesophageal reflux. Diagnostic value of barium and bread studies compared with 24-hour pH monitoring

    International Nuclear Information System (INIS)

    Aksglaede, K.; Funch-Jensen, P.; Thommesen, P.

    1999-01-01

    To correlate gastroesophageal reflux (GER), demonstrated by a radiological method using food, with the reflux events, as determined by 24-h pH monitoring. One hundred and seventeen patients with a median age of 47 years (86 male and 31 female) were examined. In the supine left position, the patient consumed 360 ml of barium contrast. Fluoroscopy was performed with the patient in the supine right oblique position during mastication and swallowing a piece of rye bread with liver pate and barium. The test was positive if barium was observed >= 5 cm proximal to the gastroesophageal junction. An antimony pH-probe was placed 5 cm above the lower esophageal sphincter, previously determined by manometry. The position was controlled by radiography after positioning and before removal. The total time of esophageal pH<4 exceeding 5.0% was considered pathological. The radiological method had a specificity of 100% and a sensitivity of 52% compared to 24-h pH monitoring. The high specificity of this radiological method justify direct therapeutic consequence of a positive test. However, a negative test still renders the problem unsolved

  7. Radiological demonstration of gastroesophageal reflux. Diagnostic value of barium and bread studies compared with 24-hour pH monitoring

    International Nuclear Information System (INIS)

    Aksglaede, K.; Thommesen, P.; Funch-Jensen, P.

    1999-01-01

    Purpose: To correlate gastroesophageal reflux (GER), demonstrated by a radiological method using food, with the reflux events, as determined by 24-h pH monitoring. Material and Methods: One hundred and seventeen patients with a median age of 47 years (86 male and 31 female) were examinated. In the supine left position, the patient consumed 360 ml of barium contrast. Fluoroscopy was performed with the patient in the supine right oblique position during mastication and swallowing a piece of rye bread with liver pate and barium. The test was positive if barium was observed ≥5 cm proximal to the gastroesophageal junction. An antimony pH-probe was placed 5 cm above the lower esophageal sphincter, previously determined by manometry. The position was controlled by radiography after positioning and before removal. The total time of esophageal pH<4 exceeding 5.0% was considered pathological. Results: The radiological method had a specificity of 100% and a sensitivity of 52% compared to 24-h pH monitoring. Conclusion: The high specificity of this radiological method justify direct therapeutic consequence of a positive test. However, a negative test still renders the problem unsolved. (orig.)

  8. Radiological demonstration of gastroesophageal reflux. Diagnostic value of barium and bread studies compared with 24-hour pH monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Aksglaede, K.; Thommesen, P. [Dept. of Diagnostic Radiology R, Aarhus Univ. Hospital, Aarhus (Denmark); Funch-Jensen, P. [Surgical Gastroenterology L, Aarhus Univ. Hospital, Aarhus (Denmark)

    1999-11-01

    Purpose: To correlate gastroesophageal reflux (GER), demonstrated by a radiological method using food, with the reflux events, as determined by 24-h pH monitoring. Material and Methods: One hundred and seventeen patients with a median age of 47 years (86 male and 31 female) were examinated. In the supine left position, the patient consumed 360 ml of barium contrast. Fluoroscopy was performed with the patient in the supine right oblique position during mastication and swallowing a piece of rye bread with liver pate and barium. The test was positive if barium was observed {>=}5 cm proximal to the gastroesophageal junction. An antimony pH-probe was placed 5 cm above the lower esophageal sphincter, previously determined by manometry. The position was controlled by radiography after positioning and before removal. The total time of esophageal pH<4 exceeding 5.0% was considered pathological. Results: The radiological method had a specificity of 100% and a sensitivity of 52% compared to 24-h pH monitoring. Conclusion: The high specificity of this radiological method justify direct therapeutic consequence of a positive test. However, a negative test still renders the problem unsolved. (orig.)

  9. Status of barium studies in the present era of oncology: Are they a history?

    Science.gov (United States)

    Mahajan, Abhishek; Desai, Subash; Sable, Nilesh Pandurang; Thakur, Meenakshi Haresh

    2016-01-01

    With the advent of the modern imaging technologies, the present era of oncology is seeing steady decline in requests for barium studies due to the many reasons. It is prudent to mention here, that, barium examinations cannot be made obsolete! Our aim to preserve the age old technique of barium studies not only to keep it going on but also for the betterment and appropriate management of the patient. Our goal is not to "save" barium studies simply to keep this technology alive, per se, but rather to preserve barium radiology for the quality in patient care.

  10. Role of Barium Swallow in Diagnosing Clinically Significant Anastomotic Leak following Esophagectomy

    Directory of Open Access Journals (Sweden)

    Simon Roh

    2016-04-01

    Full Text Available Background: Barium swallow is performed following esophagectomy to evaluate the anastomosis for detection of leaks and to assess the emptying of the gastric conduit. The aim of this study was to evaluate the reliability of the barium swallow study in diagnosing anastomotic leaks following esophagectomy. Methods: Patients who underwent esophagectomy from January 2000 to December 2013 at our institution were investigated. Barium swallow was routinely done between days 5–7 to detect a leak. These results were compared to clinically determined leaks (defined by neck wound infection requiring jejunal feeds and or parenteral nutrition during the postoperative period. The sensitivity and specificity of barium swallow in diagnosing clinically significant anastomotic leaks was determined. Results: A total of 395 esophagectomies were performed (mean age, 62.2 years. The indications for the esophagectomy were as follows: malignancy (n=320, high-grade dysplasia (n=14, perforation (n=27, benign stricture (n=7, achalasia (n=16, and other (n=11. A variety of techniques were used including transhiatal (n=351, McKeown (n=35, and Ivor Lewis (n=9 esophagectomies. Operative mortality was 2.8% (n=11. Three hundred and sixty-eight patients (93% underwent barium swallow study after esophagectomy. Clinically significant anastomotic leak was identified in 36 patients (9.8%. Barium swallow was able to detect only 13/36 clinically significant leaks. The sensitivity of the swallow in diagnosing a leak was 36% and specificity was 97%. The positive and negative predictive values of barium swallow study in detecting leaks were 59% and 93%, respectively. Conclusion: Barium swallow is an insensitive but specific test for detecting leaks at the cervical anastomotic site after esophagectomy.

  11. Studies on phase evolution and electrical conductivity of barium doped gadolinium aluminate

    International Nuclear Information System (INIS)

    Sinha, Amit; Sharma, B.P.; Gopalan, P.

    2012-01-01

    Highlights: ► Barium doped GdAlO 3 compositions were prepared from citrate gel derived powders. ► The solid solubility of barium in GdAlO 3 was less than 4 mol%. ► The un-dissolved barium precipitated in the form of BaAl 2 O 4 phase. ► The conductivity of Ba-doped GdAlO 3 increased with increasing amounts of Ba. ► In Gd 1−x Ba x AlO 3−δ system, specimen with x = 0.02 exhibited maximum conductivity. - Abstract: The phase evolution and electrical conductivity of barium doped GdAlO 3 samples have been investigated. The Ba- doped compositions of GdAlO 3 were prepared through citrate gel process. Analysis of the phases was carried out using X-ray diffraction (XRD). The morphology of the calcined powders was studied by scanning electron microscopy. The electrical conductivity of Gd 1−x Ba x AlO 3−δ (x = 0–0.04) was measured using ac impedance spectroscopy as a function of temperature ranging from 300 to 1000 °C under air. The solid solubility of barium in GdAlO 3 was found to be less than 4 mol%. The undissolved barium precipitated in the form of BaAl 2 O 4 phase. The barium doped GdAlO 3 powders obtained after calcination at 1000 °C was found to be porous agglomerate composed of nanocrystalline grains. The total electrical conductivity of Ba-doped GdAlO 3 increased with increasing amounts of barium up to 2 mol% doping.

  12. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms

    NARCIS (Netherlands)

    Saleh, C. M. G.; Smout, A. J. P. M.; Bredenoord, A. J.

    2015-01-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20

  13. Barium contributions to the valence electronic structure of YBa2Cu3O7-δ, PrBa2Cu3O7-δ, and other barium-containing compounds

    International Nuclear Information System (INIS)

    Mueller, D.R.; Wallace, J.S.; Jia, J.J.; O'Brien, W.L.; Dong, Q.; Callcott, T.A.; Miyano, K.E.; Ederer, D.L.

    1995-01-01

    Monochromatic photon beams were used to excite barium N IV,V soft x-ray emission spectra from YBa 2 Cu 3 O 7-δ , PrBa 2 Cu 3 O 7-δ , BaF 2 , and BaTiO 3 . Near threshold excitation was used to demonstrate that small contributions to the barium N V and N IV emission spectra in the energy region above the 5p→4d core-core transitions do not arise as satellite emission from transitions in multiply excited atoms but rather occur as a result of transitions from the valence states. The emission spectrum of YBa 2 Cu 3 O 7-δ and PrBa 2 Cu 3 O 7-δ reveals a contribution to the electronic density of states at the barium site in the region near the Fermi level. The YBa 2 Cu 3 O 7-δ compound is a superconductor and PrBa 2 Cu 3 O 7-δ is an insulator. It has been proposed that the difference between them is due to mixing of praseodymium and barium among the sites occupied by yttrium and barium, with an accompanying change in electronic structure. However, our measurements indicate that the barium partial density of states for the two compounds are essentially identical

  14. Synthesis and properties of barium diketonates as precursors for MOCVD

    Energy Technology Data Exchange (ETDEWEB)

    Drozdov, A.A. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Troyanov, S.I. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Kuzmina, N.P. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Martynenko, L.I. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Alikhanyan, A.S. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Malkerova, I.P. (Dept. of Chemistry, Moscow State Univ. (Russian Federation))

    1993-08-01

    The structures of barium diketonates depend on the way in which they are synthesized. It is shown that there is a correlation between the volatility of these compounds and their crystal structures. A new volatile mononuclear adduct of barium dipivaloylmethanate suitable for MOCVD is suggested. (orig.).

  15. Synthesis and properties of barium diketonates as precursors for MOCVD

    International Nuclear Information System (INIS)

    Drozdov, A.A.; Troyanov, S.I.; Kuzmina, N.P.; Martynenko, L.I.; Alikhanyan, A.S.; Malkerova, I.P.

    1993-01-01

    The structures of barium diketonates depend on the way in which they are synthesized. It is shown that there is a correlation between the volatility of these compounds and their crystal structures. A new volatile mononuclear adduct of barium dipivaloylmethanate suitable for MOCVD is suggested. (orig.)

  16. Barium hexaferrite nanoparticles: Synthesis and magnetic properties

    International Nuclear Information System (INIS)

    Martirosyan, K.S.; Galstyan, E.; Hossain, S.M.; Wang Yiju; Litvinov, D.

    2011-01-01

    Carbon combustion synthesis is applied to rapid and energy efficient fabrication of crystalline barium hexaferrite nanoparticles with the average particle size of 50-100 nm. In this method, the exothermic oxidation of carbon nanoparticles with an average size of 5 nm with a surface area of 80 m 2 /g generates a self-propagating thermal wave with maximum temperatures of up to 1000 deg. C. The thermal front rapidly propagates through the mixture of solid reactants converting it to the hexagonal barium ferrite. Carbon is not incorporated in the product and is emitted from the reaction zone as a gaseous CO 2 . The activation energy for carbon combustion synthesis of BaFe 12 O 19 was estimated to be 98 kJ/mol. A complete conversion to hexagonal barium ferrite is obtained for carbon concentration exceeding 11 wt.%. The magnetic properties H c ∼3000 Oe and M s ∼50.3 emu/g of the compact sintered ferrites compare well with those produced by other synthesis methods.

  17. Atomization of magnesium, strontium, barium and lead nitrates on surface of graphite atomizers

    International Nuclear Information System (INIS)

    Nagdaev, V.K.; Pupyshev, A.A.

    1982-01-01

    Modelling of the processes on graphite surface using differential-thermal analysis and graphite core with identification of decomposition products of magnesium, strontium, barium and lead nitrates by X-ray analysis has shown that carbon promotes the formation of strontium, barium and lead carbonates. The obtained temperatures of strontium and barium carbonate decomposition to oxides agree satisfactorily with calculation ones. Magnesium nitrate does not react with carbon. Formation of strontium and barium carbonates results in considerable slowing down of the process of gaseous oxide dissociation. Lead carbonate is unstable and rapidly decomposes to oxide with subsequent reduction to free metal. Formation of magnesium, strontium and barium free atoms is connected with appearance of gaseous oxides in analytical zone. Oxide and free metal lead are present on graphite surface simultaneously

  18. Oral contrast agents for small bowel distension in MRI: influence of the osmolarity for small bowel distention

    International Nuclear Information System (INIS)

    Ajaj, Waleed; Kuehle, Christiane; Nuefer, Michael; Goehde, Susanne C.; Lauenstein, Thomas C.; Goyen, Mathias; Schneemann, Hubert; Ruehm, Stefan G.

    2005-01-01

    To assess the effect of the osmolarity for small bowel distension in MRI, ten volunteers ingested at two separate occasions negative oral contrast agents with different quantity and osmolarity: (1) a water solution combined with 2.0% sorbitol and 0.2% locus bean gum (LBG) with a quantity of 1500 ml and an osmolarity of 148 mOsmol/l, (2) a water solution combined with 2.0% sorbitol and 2.0% barium sulphate with a quantity of 1000 ml and an osmolarity of 194 mOsmol/l. Small bowel distension was quantified on coronal 2D-TrueFISP images by measuring the small bowel diameters. There were no statistically significant differences in mean small bowel diameter between both contrast agents. The mean small bowel distension was 19.2 mm after ingestion of 1500 ml of sorbitol-LBG solution and 19.0 mm after ingestion of 1000-ml sorbitol-barium sulphate solution. Furthermore, all volunteers found the ingestion of 1000-ml solution more pleasant than the 1500-ml solution. The ingestion of 1000 ml of sorbitol-barium sulphate solution led to a sufficient small bowel distension compared to 1500 ml of sorbitol-LBG solution. The side effect rate of both solutions was low. Based on these data, we recommend a quantity of 1000 ml of sorbitol-barium sulphate solution as an alternative for 1500-ml sorbitol-LBG solution for optimal bowel distension. (orig.)

  19. Synthesis and surface properties of submicron barium sulfate particles

    International Nuclear Information System (INIS)

    Zhang Ming; Zhang Bao; Li Xinhai; Yin Zhoulan; Guo Xueyi

    2011-01-01

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO 4 particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO 4 particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO 4 were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO 4 was presented. The FTIR result indicates that the surface of the prepared BaSO 4 absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  20. Synthesis and surface properties of submicron barium sulfate particles

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Ming, E-mail: csu.light@yahoo.com.cn [College of Chemistry and Chemical Engineering, Zhaoqing University, Zhaoqing 526061 (China); School of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Zhang Bao; Li Xinhai [School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); Yin Zhoulan [School of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Guo Xueyi [School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China)

    2011-10-15

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO{sub 4} particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO{sub 4} particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO{sub 4} were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO{sub 4} was presented. The FTIR result indicates that the surface of the prepared BaSO{sub 4} absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  1. Printed Barium Strontium Titanate capacitors on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Sette, Daniele [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg); Kovacova, Veronika [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Defay, Emmanuel, E-mail: emmanuel.defay@list.lu [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg)

    2015-08-31

    In this paper, we show that Barium Strontium Titanate (BST) films can be prepared by inkjet printing of sol–gel precursors on platinized silicon substrate. Moreover, a functional variable capacitor working in the GHz range has been made without any lithography or etching steps. Finally, this technology requires 40 times less precursors than the standard sol–gel spin-coating technique. - Highlights: • Inkjet printing of Barium Strontium Titanate films • Deposition on silicon substrate • Inkjet printed silver top electrode • First ever BST films thinner than 1 μm RF functional variable capacitor that has required no lithography.

  2. Rapid and accurate determination of barium by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Maihara, Vera A.; Saiki, Mitiko; Trevizam, Anderson R.

    2013-01-01

    Barium is an alkaline earth metal naturally present in soils. When available at a high level in the soil it can cause toxicity to plants and animals. Not all the barium is readily available to living organisms. Inorganic and organic barium compounds can be presented as soluble or insoluble forms in the soil. The soluble form of BaS is extremely toxic to humans, animals and plants. Researchers have noted a decrease of K absorption in the plant when Ba concentrations are increased and a change in overall plant growth. In case of animals, Ba tends to be concentrated in the bones which may compete with calcium, although only about 2% barium ingested in dietary is absorbed by the body. Another effect is that the Ba can interfere with the availability of sulfur in the soil due to the sulphate formation of low solubility. Barium and some other elements are considered palioclimatic proxies. For some researchers, barite is perhaps the most appropriate indicator of paleoproductivity because of a high resistance to dissolution. As explained about the barium effects in various situations, it was considered important to study the more appropriated experimental conditions for determination of this element by INAA. Conditions established for this analysis were: a) Irradiation time, 15 and 40 seconds, under thermal flux neutron about 4 x 10 12 n cm -2 s -1 , for determining barium in geological and biological matrices, respectively; b) Decay time, approximately of 4 minutes; c) Counting time of 30 minutes; d) Radionuclide measured 139 Ba. The quality of Ba results was evaluated from the analysis of certified reference materials. The performance of the method was satisfactory, according to the criterion of E.ζ score. Results obtained in this study indicate INAA is a good alternative for Ba determination in geological and biological samples. (author)

  3. Preoperative assessment of intestinal endometriosis: A comparison of transvaginal sonography with water-contrast in the rectum, transrectal sonography, and barium enema.

    Science.gov (United States)

    Bergamini, Valentino; Ghezzi, Fabio; Scarperi, Stefano; Raffaelli, Ricciarda; Cromi, Antonella; Franchi, Massimo

    2010-12-01

    To evaluate the accuracy of Transrectal Sonography (TRS) and a new technique, Transvaginal Sonography with Water-Contrast in the Rectum (RWC-TVS), in the diagnosis of rectosigmoid endometriosis, and the accuracy of Barium Enema (BE) and RWC-TVS in the detection of intestinal stenosis due to endometriosis. In a prospective study, we compared the findings of TRS and RWC-TVS performed before surgery with the operative and pathologic findings in 61 consecutive patients who underwent laparoscopy or laparotomy for suspected rectosigmoid endometriosis. The accuracy of BE and RWC-TVS in the detection of intestinal stenosis was evaluated comparing the radiologic and ultrasonographic results with the macroscopic findings at surgery and pathology. RWC-TVS diagnosed rectosigmoid endometriosis with the same accuracy of TRS and was equally efficient as BE in the detection of a significant intestinal lumen stenosis. For the diagnosis of rectosigmoid endometriosis the sensitivity, specificity, positive and negative predictive values of TRS and RWC-TVS were 88.2% and 96%, 80%, and 90%, 95.7%, and 98%, and 57.1% and 81.8%, respectively. For the detection of intestinal stenosis the sensitivity, specificity, positive and negative predictive values of BE and RWC-TVS were 93.7% and 87.5%, 94.2% and 91.4%, 88.2% and 82.3%, and 97% and 94.1%, respectively. RWC-TVS is a new, simple technique for a single-step and accurate preoperative assessment of rectosigmoid endometriosis.

  4. CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Torres, Andrew S; Bonitatibus, Peter J; Yeh, Benjamin M

    2016-03-01

    To quantify the computed tomographic (CT) image contrast produced by potentially useful contrast material elements in clinically relevant imaging conditions. Equal mass concentrations (grams of active element per milliliter of solution) of seven radiodense elements, including iodine, barium, gadolinium, tantalum, ytterbium, gold, and bismuth, were formulated as compounds in aqueous solutions. The compounds were chosen such that the active element dominated the x-ray attenuation of the solution. The solutions were imaged within a modified 32-cm CT dose index phantom at 80, 100, 120, and 140 kVp at CT. To simulate larger body sizes, 0.2-, 0.5-, and 1.0-mm-thick copper filters were applied. CT image contrast was measured and corrected for measured concentrations and presence of chlorine in some compounds. Each element tested provided higher image contrast than iodine at some tube potential levels. Over the range of tube potentials that are clinically practical for average-sized and larger adults-that is, 100 kVp and higher-barium, gadolinium, ytterbium, and tantalum provided consistently increased image contrast compared with iodine, respectively demonstrating 39%, 56%, 34%, and 24% increases at 100 kVp; 39%, 66%, 53%, and 46% increases at 120 kVp; and 40%, 72%, 65%, and 60% increases at 140 kVp, with no added x-ray filter. The consistently high image contrast produced with 100-140 kVp by tantalum compared with bismuth and iodine at equal mass concentration suggests that tantalum could potentially be favorable for use as a clinical CT contrast agent.

  5. Measurement of microbic contamination rate in the dispensing process making suspension of barium sulfate powder

    International Nuclear Information System (INIS)

    Kim, Young Keun; Lee, Yang Sub; Cho, Cheong Chan; Ryu, Meung Sun; Lee, Kyung Sup

    2001-01-01

    The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus coli were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured. Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensable to manufacturing suspension for preventing from infection

  6. TV observations of the Barium-GEOS ion jet experiment

    International Nuclear Information System (INIS)

    Hapgood, M.A.; Collin, H.L.; Rothwell, P.

    1980-01-01

    The barium jet released by the Barium-GEOS rocket was observed by low light television cameras at Skibotn, Norway and Esrange, Sweden. The release produced a single well-defined jet containing barium ions with initial velocities between 7 and 12 km s -1 systematically slower than the velocities reported in previous experiments. Accurate data on the motion of the jet has been obtained for the first two minutes after release (up to a height of 2000 km). The orientation of the jet was close to that of an IGRF1975 model field line but was significantly different from that predicted by the Barraclough and Olson field model. The motion of the jet across the field lines was southwards with a velocity of about 150 m s -1 . (Auth.)

  7. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  8. Normal anatomy and pathological changes of the infrapatellar pad of fat in double contrast arthrography

    International Nuclear Information System (INIS)

    Boehnke, E.

    1980-01-01

    The diagnostic validity of double-contrast angiography in patients with Hoffa's disease was studied by re-evaluation of 1566 arthrographs without knowing the surgical findings. In order to obtain more information on the anatomy and pathology of the intrapatellar pad of fat, so knee joints of corpses were dissected who had died at different stages of life. As the studies showed, the decisive diagnostic factors in Hoffa's disease are the clinical complaints and an enlarged pad of fat in the arthrographic picture. (orig.) [de

  9. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    International Nuclear Information System (INIS)

    Baron, J.; Alexander, T.

    2003-01-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  10. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    Energy Technology Data Exchange (ETDEWEB)

    Baron, J.; Alexander, T. [Univ. of Alberta, Dept. of Radiology, Edmonton, Alberta (Canada)

    2003-06-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  11. Barium fluoride surface preparation, analysis and UV reflective coatings at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Wuest, C.R.

    1992-01-01

    Lawrence Livermore National Laboratory (LLNL) has begun a program of study on barium fluoride scintillating crystals for the Barium Fluoride Electromagnetic Calorimeter Collaboration. This program has resulted in a number of significant improvements in the mechanical processing, polishing and coating of barium fluoride crystals. Techniques have been developed using diamond-loaded pitch lapping that can produce 15 angstrom RMS surface finishes over large areas. These lapped surfaces have been shown to be crystalline using Rutherford Back-scattering (RBS). Also, special polishing fixtures have been designed based on mounting technology developed for the 1.1 m diameter optics used in LLNL's Nova Laser. These fixtures allow as many as five 25--50 cm long barium fluoride crystals to be polished and lapped at a time with the necessary tolerances for the 16,000 crystal Barium Fluoride Calorimeter. In addition, results will be presented on coating barium fluoride with UV reflective layers of magnesium fluoride and aluminum

  12. Survey of effective doses to patients undergoing contrast-based X-ray fluoroscopy procedures in Tanzania

    International Nuclear Information System (INIS)

    Ngaile, J.E.; Msaki, P.K.; Kazema, R.R.

    2017-01-01

    The aim of this study was to assess the radiation burden imparted to patients from contrast-based X-ray fluoroscopy procedures in Tanzania. The effective doses (EDs) to patients from five contrast-based fluoroscopy procedures were obtained from four hospitals. The ED was estimated using the knowledge of the patient characteristics, patient-related exposure parameters, measurements of air kerma area product and PCXCM software. The median EDs for the barium swallow (BS), barium meal (BM), barium enema (BE), hysterosalpingography (HSG) and retrograde urethrography (RUG) were 0.50, 1.43, 2.83, 0.65 and 0.59 mSv, respectively. The median ED per hospital for the BS and BM procedures varied by factors of up to 9.9 and 4.2, respectively, while for the BE, HSG and RUG varied by factors of up to 2.3, 2.4 and 4.3, respectively. The overall differences between individual EDs across the four hospitals varied by factors of up to 53, 58.9 and 11.4 for the BS, BM and BE, respectively, while for the HSG and RUG differed by factors of up to 22 and 46.7, respectively. The mean EDs in this study were mostly lower than reported values from Spain, the UK, Ghana and Greece, while slightly higher than those reported from India. The observed wide variations of procedural protocols and patient doses within and across the hospitals; and the observed high patient doses in this study relative to those from the literature call for the need to standardize procedural protocols and optimize contrast-based fluoroscopy procedures. (authors)

  13. Colonoscopy can miss diverticula of the left colon identified by barium enema.

    Science.gov (United States)

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-04-21

    To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.

  14. Experimental studies on 3D printing of barium titanate ceramics for medical applications

    Directory of Open Access Journals (Sweden)

    Schult Mark

    2016-09-01

    Full Text Available The present work deals with the 3D printing of porous barium titanate ceramics. Barium titanate is a biocompatible material with piezoelectric properties. Due to insufficient flowability of the starting material for 3D printing, the barium titanate raw material has been modified in three different ways. Firstly, barium titanate powder has been calcined. Secondly, flow additives have been added to the powder. And thirdly, flow additives have been added to the calcined powder. Finally, a polymer has been added to the three materials and specimens have been printed from these three material mixtures. The 3D printed parts were then sintered at 1320°C. The sintering leads to shrinkage which differs between 29.51–71.53% for the tested material mixtures. The porosity of the parts is beneficial for cell growth which is relevant for future medical applications. The results reported in this study demonstrate the possibility to fabricate porous piezoelectric barium titanate parts with a 3D printer that can be used for medical applications. 3D printed porous barium titanate ceramics can especially be used as scaffold for bone tissue engineering, where the bone formation can be promoted by electrical stimulation.

  15. Barium ionization mechanisms in the CRRES G-1 and G-11b releases

    International Nuclear Information System (INIS)

    Hunton, D.E.

    1993-01-01

    The G-11b chemical release experiment form the Combined Release and Radiation Effects Satellite (CRRES) was conducted in darkness below the solar UV terminator to test the Critical Ionization Velocity (CIV) hypothesis. The Quadrupole Ion Mass Spectrometer (QIMS) aboard CRRES measured fluxes of barium ions from this darkness release that were only a factor of ten smaller than the G-1 release measurements in full sunlight. Possible mechanisms for this significant barium ionization in darkness include CIV, charge exchange with O + , collisional ionization and associative ionization. The authors have evaluated the relative contributions of the collisional mechanisms by constructing a simple model of barium ions from the darkness release seem to be consistent with recent measurements of the charge transfer cross section. A collective plasma ionization mechanism such as CIV does not seem to necessary in order to explain the large barium ion fluxes observed. However, QIMS could only detect barium ions formed several seconds after the initial detonation of the release canister. A CIV process could still have occurred very early in the expansion of the barium neutral cloud and the mass spectrometer would not have detected these ions

  16. Gas thermodesorption study of barium and strontium cerates

    International Nuclear Information System (INIS)

    Aksenova, T.I.; Khromushin, I.V.; Zhotabaev, Zh.R.; Bukenov, K.D.; Medvedeva, Z.V.; Berdauletov, A.K.

    2002-01-01

    Kinetic of water, oxygen, hydrogen and carbon dioxide molecules release from doped and undoped samples of barium cerates and doped strontium cerates during vacuum heating was studied. The samples were prepared by inductive melting method. The following two kinds of preliminary samples treatments were used: annealing in air (650-750 deg. C) and wet nitrogen atmosphere (625 deg.C). Main results of thermodesorption studies of barium and strontium cerates are represented in the table. The samples of doped LaSrMnO were investigated also. It was found that the initial doped samples (without preliminary annealing) did not show any gas release in temperature range of 20-1100 deg. C. This fact indicates on high stability of compositions and strong bond of 'host' oxygen in their lattice. A significant amount of water and oxygen molecules were released from BaCe 0.9 Nd 0.1 O 3 samples whereas water and hydrogen molecules desorption from SrCe 0.95 Y 0.05 O 3 samples took place. Hydrogen molecules desorption was found for strontium cerates samples; no hydrogen molecules release was observed for doped and pure barium cerate samples.Intensive water molecules release from doped samples confirms the necessity of oxygen vacancies creation in these compounds to get properties of proton conductivity, since it was not found any water molecules release from annealed undoped samples of BaCeO 3 It is necessary to notice that oxygen molecules release from these samples took place at ∼1000 deg. C that is significantly higher then from BaCeNdO samples. Forms of high temperatures part of oxygen and low temperature part of water spectra indicate that phase transformations are responsible for oxygen and water molecules desorption in this cases. These results are in good agreement with literature data. Desorption of water molecules from barium and strontium cerates took place. Oxygen desorption took place only from barium cerates. It can be explained as the following: doped barium cerates have

  17. Complete sulphate removal from neutralised acidic mine drainage with barium carbonate

    CSIR Research Space (South Africa)

    Swanepoel, H

    2012-03-01

    Full Text Available -barium-calcium) Desalination process which uses barium salts to further reduce the sulphate concentration to acceptable levels with the added advantage that sulphate removal can be controlled due to the low solubility of BaSO4. This paper reports on the results...

  18. Accuracy of the double contrast technique in the detection of small lesions of the colon

    Energy Technology Data Exchange (ETDEWEB)

    Muzzio, P C; Pomerri, F; Feltrin, G P; Biondetti, P R; Di Maggio, C [Padua Univ. (Italy). Istituto di Radiologia e Fisioterapia

    1979-02-01

    Double contrast enema has become an indispensible aid in early lesions of the colon, in particular for small lesions. According to the authors' opinion, the method provides so much additional information that it ought to be applied at all rates in such cases. It is neither expensive nor time-consuming and can easily be carried out in any X-ray department, especially where a fibroscope is not available. The results are reliable if the technique is applied correctly, if the patient is well-prepared, and if the radiologist has enough technical and semiological experience.

  19. Barium titanate coated with magnesium titanate via fused salt method and its dielectric property

    International Nuclear Information System (INIS)

    Chen Renzheng; Cui Aili; Wang Xiaohui; Li Longtu

    2003-01-01

    Barium titanate fine particles were coated homogeneously with magnesium titanate via the fused salt method. The thickness of the magnesium titanate film is 20 nm, as verified by TEM and XRD. The mechanism of the coating is that: when magnesium chloride is liquated in 800 deg. C, magnesium will replace barium in barium titanate, and form magnesium titanate film on the surface of barium titanate particles. Ceramics sintered from the coated particles show improved high frequency ability. The dielectric constant is about 130 at the frequency from 1 to 800 MHz

  20. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    Science.gov (United States)

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Barium in produced water: Is it a toxicological hazard to the marine environment?

    International Nuclear Information System (INIS)

    Neff, J.M.

    1993-01-01

    Produced water is a complex aqueous mixture of organic and inorganic chemicals that often is generated in large volumes as a by-product of production of oil and gas. Produced water from offshore oil production platforms sometimes is treated to remove particulate oil and then discharged to the ocean. Barium often is the most abundant inorganic chemical, other than the dominant sea salts, in produced water. Some concern has been expressed that the large amounts of barium discharged to the ocean in produced water may have adverse effects on marine biological communities. The ecological risks associated with discharge to the ocean in produced water may have adverse effects on marine biological communities. The ecological risks associated with discharge to the ocean of barium in produced water were evaluated. Concentrations of barium in produced water from different sources range from less than 1.0 to about 2,000 mg/L, and are inversely correlated with concentrations of sulfate. Concentrations of barium in the ocean usually are in the range of 10 to 20 μg/L; the ocean is undersaturated with respect to barite (BaSO 4 ). During mixing and dilution of a produced water plume in the ocean, barium reacts with the abundant sulfate in seawater and precipitates as barite. Barite is completely nontoxic to marine organisms. Because of the high concentration of sulfate in the ocean, ionic barium can not reach concentrations high enough to be toxic to marine organisms

  2. Prognostic model for patients treated for colorectal adenomas with regard to development of recurrent adenomas and carcinoma

    DEFF Research Database (Denmark)

    Jensen, P; Krogsgaard, M R; Christiansen, J

    1996-01-01

    -80. INTERVENTIONS: All patients were followed up by rectoscopy and double contrast barium enema. The survival data were analysed by Cox's proportional hazards model. MAIN OUTCOME MEASURES: Variables of significant prognostic importance for recurrence of adenomas and the development of cancer were identified...

  3. Formation of barium strontium titanate powder by solid state reaction using different calcination temperatures

    International Nuclear Information System (INIS)

    Teoh Wah Tzu; Ahmad Fauzi Mohd Noor; Zainal Arifin Ahmad

    2002-01-01

    The unique electrical properties of large permittivity in Barium Strontium Titanate have been widely used to make capacitors; it can be produced by solid state reaction. In this study, the mixture of Barium Carbonate, Strontium Carbonate and Titanium Dioxide was calcined at 500 degree C, 1000 degree C, 1100 degree C , 1150 degree C, 1200 degree C, 1250 degree C and 1300 degree C. The results of the phases change in each stage were investigated via X ay Diffraction. The results show that the formation of Barium Strontium Titanate started at 1100 degree C with the presence of other phases. The mixture is fully reacted to form Barium Strontium Titanate at 1150 degree C. Only Barium Strontium Titanate was formed as the calcination temperature was set higher. (Author)

  4. Influence of fuel ratios on auto combustion synthesis of barium ferrite ...

    Indian Academy of Sciences (India)

    Unknown

    Influence of fuel ratios on auto combustion synthesis of barium ferrite nano particles. D BAHADUR*, S RAJAKUMAR and ANKIT KUMAR. Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology,. Mumbai 400 076 e-mail: dhirenb@iitb.ac.in. Abstract. Single-domain barium ferrite nano ...

  5. Strontium-90 sorption from fresh waters in the process of barium manganite modification

    International Nuclear Information System (INIS)

    Ryzhen'kov, A.P.; Egorov, Yu.V.

    1995-01-01

    Strontium-90 extraction by barium manganite from fresh water (natural non-salty water in open ponds) may be increased adding to the solution the sulfate anion containing reagents that modify a sorbent and chemically bind a sorbate. Heterogeneous anion-exchanging reaction of barium manganite transformation into barium sulfate-manganese dioxide and simultaneous coprecipitation of strontium sulfate (microelement) occur as a result of it. 9 refs., 4 figs., 1 tab

  6. Small bowel volvulus in children. Its appearance on the barium enema examination

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, M.J.; Shackelford, G.D.; McAlister, W.H.

    1980-01-01

    Two children with small bowel volvulus diagnosed on barium enema examination are reported. In one patient the volvulus was associated with malrotation and in the other patient there was a post-operative peritoneal adhesion. In both cases the diagnosis was based on beaking of the head of the barium column at the site of volvulus. Radiographic demonstration of a beak sign in the small bowel on barium enema examination should suggest a diagnosis of small bowel volvulus, and indicates the need for immediate surgery.

  7. Tunable double-channel filter based on two-dimensional ferroelectric photonic crystals

    International Nuclear Information System (INIS)

    Jiang, Ping; Ding, Chengyuan; Hu, Xiaoyong; Gong, Qihuang

    2007-01-01

    A tunable double-channel filter is presented, which is based on a two-dimensional nonlinear ferroelectric photonic crystal made of cerium doped barium titanate. The filtering properties of the photonic crystal filter can be tuned by adjusting the defect structure or by a pump light. The influences of the structure disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed

  8. Tunable double-channel filter based on two-dimensional ferroelectric photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ping [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); Ding, Chengyuan [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); Hu, Xiaoyong [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China)]. E-mail: xiaoyonghu@pku.edu.cn; Gong, Qihuang [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China)]. E-mail: qhgong@pku.edu.cn

    2007-04-02

    A tunable double-channel filter is presented, which is based on a two-dimensional nonlinear ferroelectric photonic crystal made of cerium doped barium titanate. The filtering properties of the photonic crystal filter can be tuned by adjusting the defect structure or by a pump light. The influences of the structure disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed.

  9. Characterization of barium titanate powder doped with sodium and potassium ions by using Rietveld refining

    International Nuclear Information System (INIS)

    Andrade, M.C.; Assis, J.T.; Pereira, F.R.

    2009-01-01

    A solid-reaction synthesis of doped barium titanate was done by employing barium carbonates, sodium, potassium and titanium oxides with classic procedures. Rietveld refining of X ray diffraction data of perovskite samples with tetragonal symmetry was applying and show good agreement. Besides, the treatment performed from 600 deg C produces nanocrystals of barium titanate with average size of 33 nm. The presence of endothermic peaks related to BaTiO 3 formation at relatively low temperatures was determined by thermal analysis. A pseudo-Voigt Thompson-Cox-Hastings function was used to fit the standard samples of barium titanate. The Rietveld method has showed be efficient to detect the influences of temperature and doping on barium titanate microstructures. (author)

  10. How does esophagus look on barium esophagram in pediatric eosinophilic esophagitis?

    Science.gov (United States)

    Al-Hussaini, Abdulrahman; AboZeid, Amany; Hai, Abdul

    2016-08-01

    The clinical, endoscopic, and histologic findings of eosinophilic esophagitis (EoE) are well characterized; however, there have been very limited data regarding the radiologic findings of pediatric EoE. We report on the radiologic findings of pediatric EoE observed on barium esophagram and correlate them with the endoscopic findings. We identified children diagnosed with EoE in our center from 2004 to 2015. Two pediatric radiologists met after their independent evaluations of each fluoroscopic study to reach a consensus on each case. Clinical and endoscopic data were collected by retrospective chart review. Twenty-six pediatric EoE cases (age range 2-13 years; median 7.5 years) had barium esophagram done as part of the diagnostic approach for dysphagia. Thirteen children had abnormal radiologic findings of esophagus (50%): rings formation (n = 4), diffuse irregularity of mucosa (n = 8), fixed stricture formation (n = 3), and narrow-caliber esophagus (n = 10). Barium esophagram failed to show one of 10 cases of narrow-caliber esophagus and 10 of 14 cases of rings formation visualized endoscopically. The mean duration of symptoms prior to diagnosis of EoE was longer (3.7 vs. 1.7 year; p value 0.019), and the presentation with intermittent food impaction was commoner in the group with abnormal barium esophagram as compared to the group with normal barium esophagram (69% vs. 8%; p value 0.04). Barium swallow study is frequently normal in pediatric EoE. With the exception of narrow-caliber esophagus, our data show poor correlation between radiologic and endoscopic findings.

  11. Tunable ferromagnetic resonance in La-Co substituted barium hexaferrites at millimeter wave frequencies

    Science.gov (United States)

    Korolev, Konstantin A.; Wu, Chuanjian; Yu, Zhong; Sun, Ke; Afsar, Mohammed N.; Harris, Vincent G.

    2018-05-01

    Transmittance measurements have been performed on La-Co substituted barium hexaferrites in millimeter waves. Broadband millimeter-wave measurements have been carried out using the free space quasi-optical spectrometer, equipped with a set of high power backward wave oscillators covering the frequency range of 30 - 120 GHz. Strong absorption zones have been observed in the millimeter-wave transmittance spectra of all La-Co substituted barium hexaferrites due to the ferromagnetic resonance. Linear shift of ferromagnetic resonance frequency as functions of La-Co substitutions have been found. Real and imaginary parts of dielectric permittivity of La-Co substituted barium hexaferrites have been calculated using the analysis of recorded high precision transmittance spectra. Frequency dependences of magnetic permeability of La-Co substituted barium hexaferrites, as well as saturation magnetization and anisotropy field have been determined based on Schlömann's theory for partially magnetized ferrites. La-Co substituted barium hexaferrites have been further investigated by DC magnetization to assess magnetic behavior and compare with millimeter wave data. Consistency of saturation magnetization determined independently by both millimeter wave absorption and DC magnetization have been found for all La-Co substituted barium hexaferrites. These materials seem to be quite promising as tunable millimeter wave absorbers, filters, circulators, based on the adjusting of their substitution parameters.

  12. Depiction of normal gastrointestinal anatomy with MDCT: Comparison of low- and high-attenuation oral contrast media

    International Nuclear Information System (INIS)

    Erturk, Sukru Mehmet; Mortele, Koenraad J.; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G.; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R.

    2008-01-01

    Purpose: To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). Materials and methods: A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Results: Duodenal, jejunal and ileal distention (p < 0.05, <0.001, <0.001, respectively) and wall visualization (p < 0.05, <0.01, <0.05, respectively) scores with low-attenuation contrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (p < 0.05, <0.01, respectively) were significantly higher than those with high-attenuation contrast medium, for reader 2. Interobserver agreement was fair to good for both distention (κ-range: 0.41-0.74) and wall visualization (κ-range: 0.48-0.71). Conclusion: MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium

  13. Double-contrast gastrography and gastroscopy in the diagnosis of gastric polyps. Personal experience

    Energy Technology Data Exchange (ETDEWEB)

    Biscarini, R; Giorgi, G; Lazzari, G and others

    1986-01-01

    Gastric polyps are benign tumors which have been less uncommonly detected in recent years, due to the refinement of both radiologic and endoscopic investigations. From 1981 through 1985 gastric polyps were detected in 102 patients (1,9%) out of 5368 radiologic examination. In the same period, 98 cases (3,3%) were detected out of 2942 endoscopic examination. The comparison of data in these two series shows a superimposition. Despite an increased percentage of endoscopic findings (to some extent due to previous radiologic reports), the authors assert the diagnostic efficacy of double contrast radiologic investigation as a first approach to benign polypous lesions of the stomach. As far as histology is concerned, a clear prevalence is shown of hyperplastic versus adenomatous polyps (90 and 8 cases repectively).

  14. Study of interferences in the atomic - absorption and emission of barium in nitrous oxide/acetylene flame

    International Nuclear Information System (INIS)

    Curtius, A.J.; Couto, M.I.

    1979-01-01

    The interferences of several ions that are present in oifield water and sea water in the atomic absorption and emission of barium were investigated. It was verified that the interferences of sodium, potassium, calcium, strontium and chloride are the most important. The indirect method for the determination of sulfate by measuring barium by atomic absorption after precipitating barium sulfate with an excess of barium chloride, should not be used for highly salted matrix. To avoid the interferences that are not compensated by an ionization supressor, the measurement of barium by the standard addition method or a previous sulfate separation is recommended. (Author) [pt

  15. Lanthanide doped strontium-barium cesium halide scintillators

    Science.gov (United States)

    Bizarri, Gregory; Bourret-Courchesne, Edith; Derenzo, Stephen E.; Borade, Ramesh B.; Gundiah, Gautam; Yan, Zewu; Hanrahan, Stephen M.; Chaudhry, Anurag; Canning, Andrew

    2015-06-09

    The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped strontium-barium, optionally cesium, halide, useful for detecting nuclear material.

  16. New efficient catalyst for ammonia synthesis: barium-promoted cobalt on carbon

    DEFF Research Database (Denmark)

    Hagen, Stefan; Barfod, Rasmus; Fehrmann, Rasmus

    2002-01-01

    Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia......Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia...

  17. Barium Isotopes in Single Presolar Grains

    Science.gov (United States)

    Pellin, M. J.; Davis, A. M.; Savina, M. R.; Kashiv, Y.; Clayton, R. N.; Lewis, R. S.; Amari, S.

    2001-01-01

    Barium isotopic compositions of single presolar grains were measured by laser ablation laser resonant ionization mass spectrometry and the implications of the data for stellar processes are discussed. Additional information is contained in the original extended abstract.

  18. Synthesis and characterization of barium ferrite–silica nanocomposites

    International Nuclear Information System (INIS)

    Aguilar-González, M.A.; Mendoza-Suárez, G.; Padmasree, K.P.

    2013-01-01

    In this work, we prepared barium ferrite-silica (BaM-SiO 2 ) nanocomposites of different molar ratios by high-energy ball milling, followed by heat-treatment at different temperatures. The microstructure, morphology and magnetic properties were characterized for different synthesis conditions by using X-ray diffraction (XRD), scanning electron microscopy (SEM) and vibrating sample magnetometry (VSM). The results indicate that 15 h of milling was enough to avoid the generation of hematite phase and to get a good dispersion of barium ferrite particles in the ceramic matrix. For milling periods beyond 15 h and heat treatment above 900 °C, the XRD patterns showed the presence of hematite phase caused by the decomposition of BaM. The agglomerate size observed through SEM analysis was around 150 nm with a good BaM dispersion into the SiO 2 matrix. The highest saturation magnetization (Ms) value obtained was 43 emu/g and the corresponding coercivity (Hc) value of 3.4 kOe for the composition 60BaM-40SiO 2 milled for 15 h and heat treated at 900 °C. This coercivity value is acceptable for the application in magnetic recording media. Highlights: • Barium ferrite–silica nanocomposites were prepared by high energy ball milling. • Optimal processing time is 15 h milling and heat treatment at 900 °C. • This is enough to avoid the generation of hematite phase. • Obtain good dispersion of barium ferrite particles in the ceramic matrix • Above this processing time shows the presence of increased amount of hematite

  19. Controlling Barium Sulphate Scale Deposition Problems in an unbleached Kraft Paper Mill

    CSIR Research Space (South Africa)

    Sithole, Bruce

    2015-06-01

    Full Text Available Troubleshooting of scale deposits and defects in paper samples showed that the problem was caused by barium sulphate and calcium sulphate scales. However, it was ascertained that barium sulphate was more of a concern than calcium sulphate...

  20. Development of biomonitoring equivalents for barium in urine and plasma for interpreting human biomonitoring data.

    Science.gov (United States)

    Poddalgoda, Devika; Macey, Kristin; Assad, Henry; Krishnan, Kannan

    2017-06-01

    The objectives of the present work were: (1) to assemble population-level biomonitoring data to identify the concentrations of urinary and plasma barium across the general population; and (2) to derive biomonitoring equivalents (BEs) for barium in urine and plasma in order to facilitate the interpretation of barium concentrations in the biological matrices. In population level biomonitoring studies, barium has been measured in urine in the U.S. (NHANES study), but no such data on plasma barium levels were identified. The BE values for plasma and urine were derived from U.S. EPA's reference dose (RfD) of 0.2 mg/kg bw/d, based on a lower confidence limit on the benchmark dose (BMDL 05 ) of 63 mg/kg bw/d. The plasma BE (9 μg Ba/L) was derived by regression analysis of the near-steady-state plasma concentrations associated with the administered doses in animals exposed to barium chloride dihydrate in drinking water for 2-years in a NTP study. Using a human urinary excretion fraction of 0.023, a BE for urinary barium (0.19 mg/L or 0.25 mg/g creatinine) was derived for US EPA's RfD. The median and the 95 th percentile barium urine concentrations of the general population in U.S. are below the BE determined in this study, indicating that the population exposure to inorganic barium is expected to be below the exposure guidance value of 0.2 mg/kg bw/d. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  1. Severe acute cholangitis after endoscopic sphincterotomy induced by barium examination: A case report.

    Science.gov (United States)

    Zhang, Zhen-Hai; Wu, Ya-Guang; Qin, Cheng-Kun; Su, Zhong-Xue; Xu, Jian; Xian, Guo-Zhe; Wu, Shuo-Dong

    2012-10-21

    Endoscopic sphincterotomy (EST) is considered as a possible etiological factor for severe cholangitis. We herein report a case of severe cholangitis after endoscopic sphincterotomy induced by barium examination. An adult male patient presented with epigastric pain was diagnosed as having choledocholithiasis by ultrasonography. EST was performed and the stone was completely cleaned. Barium examination was done 3 d after EST and severe cholangitis appeared 4 h later. The patient was recovered after treated with tienam for 4 d. Barium examination may induce severe cholangitis in patients after EST, although rare, barium examination should be chosen cautiously. Cautions should be also used when EST is performed in patients younger than 50 years to avoid the damage to the sphincter of Oddi.

  2. Reaction between barium and nitrogen in liquid sodium

    International Nuclear Information System (INIS)

    Addison, C.C.; Pulham, R.J.; Trevillion, E.A.

    1975-01-01

    Nitrogen in increasing amounts has been added to separate solutions of barium in sodium of constant composition (ca.4.40 mol % Ba) at 300 0 C. After rendering each mixture homogenous using an electromagnetic pump, filtration, and nitrogen analysis, all the N 2 added has been found in solution up to a solution composition approximating to Ba 4 N (i.e. 1.1 mol % N) beyond which the quantity of dissolved N 2 decreases progressively due to precipitation of the nitride Ba 2 N. The solubilization is interpreted in terms of strong preferential solvation of the nitride ion by barium cations. (author)

  3. Barium atoms and N20 molecular agregates reaction

    International Nuclear Information System (INIS)

    Visticot, J.P.; Mestdagh, J.M.; Alcaraz, C.; Cuvellier, J.; Berlande, J.

    1988-06-01

    The collisions between a barium atom and N20 molecular agregates are studied, for a better understanding of the solvation part in a chemical reaction. The experiments are carried out in a crossed molecular beam device. The light coming from the collision zone is scattered, and analysed by means of a photon detector. A time-of-flight technique is applied in the investigation of the beam's polymer concentration. The results show a nearly negligible chemiluminescent effect in the reaction between barium and N20 polymer. A solvated BaO formation mechanism is proposed to justify the experimental results [fr

  4. Regeneration of barium carbonate from barium sulphide in a pilot-scale bubbling column reactor and utilization for acid mine drainage.

    Science.gov (United States)

    Mulopo, J; Zvimba, J N; Swanepoel, H; Bologo, L T; Maree, J

    2012-01-01

    Batch regeneration of barium carbonate (BaCO(3)) from barium sulphide (BaS) slurries by passing CO(2) gas into a pilot-scale bubbling column reactor under ambient conditions was used to assess the technical feasibility of BaCO(3) recovery in the Alkali Barium Calcium (ABC) desalination process and its use for sulphate removal from high sulphate Acid Mine Drainage (AMD). The effect of key process parameters, such as BaS slurry concentration and CO(2) flow rate on the carbonation, as well as the extent of sulphate removal from AMD using the recovered BaCO(3) were investigated. It was observed that the carbonation reaction rate for BaCO(3) regeneration in a bubbling column reactor significantly increased with increase in carbon dioxide (CO(2)) flow rate whereas the BaS slurry content within the range 5-10% slurry content did not significantly affect the carbonation rate. The CO(2) flow rate also had an impact on the BaCO(3) morphology. The BaCO(3) recovered from the pilot-scale bubbling column reactor demonstrated effective sulphate removal ability during AMD treatment compared with commercial BaCO(3).

  5. Determination of barium in natural waters by ICP-OES technique. Part II: Assessment of human exposure to barium in bottled mineral and spring waters produced in Poland.

    Science.gov (United States)

    Garboś, Sławomir; Swiecicka, Dorota

    2013-01-01

    A method of the classification of natural mineral and spring waters and maximum admissible concentration (MAC) levels of metals present in such types of waters are regulated by Commission Directive 2003/40/EC, Directive 2009/54/EC of the European Parliament and of the Council and Ordinance of Minister of Health of 30 March 2011 on the natural mineral waters, spring waters and potable waters. MAC of barium in natural mineral and spring waters was set at 1.0 mg/l, while World Health Organization determined the Ba guideline value in water intended for human consumption at the level of 0.7 mg/l. The aims of the study were: the determination of barium in natural mineral and spring waters (carbonated, non-carbonated and medium-carbonated waters) produced and bottled on the area of Poland, and assessment of human exposure to this metal presents in the above-mentioned types of waters. The study concerning barium determinations in 23 types of bottled natural mineral waters and 15 types of bottled spring waters (bought in Polish retail outlets) was conducted in 2010. The analyses were performed by validated method of determination of barium in water based on inductively coupled plasma optical emission spectrometry, using modern internal quality control scheme. Concentrations of barium determined in natural mineral and spring waters were in the ranges from 0.0136 mg/l to 1.12 mg/l and from 0.0044 mg/l to 0.43 mg/l, respectively. Only in the single case of natural mineral water the concentration of barium (1.12 mg/l), exceeded above-mentioned MAC for this metal, which is obligatory in Poland and the European Union - 1.0 mg/l. The long-term monitoring of barium concentration in another natural mineral water (2006 - 2010), in which incidental exceeding MAC was observed in 2006, was conducted. All measured barium concentrations in this water were lower than 1.0 mg/l and therefore, it is possible to state that the proper method of mixing waters taken from six independent

  6. An experimental study on sterilized barium sulfate (BaSO4) for vertebroplasty

    International Nuclear Information System (INIS)

    Chen Long; Ni Caifang; Ding Yi; Wang Yijin

    2005-01-01

    Objective: To search the proper sterilization method of barium for vertebroplasty. Methods: Perfusion agents were classified into two groups with ratio of powder/liquid(g/ml) as 3:2, and the percentage of BsSO 4 in powder was 20%. The barium powder in one group was sterilized by dry-heat and by ethylene oxide in the other. The barium powder of each group was germicultured and the polymerization time, CT value, strength and stiffness were measured respectively including 6 samples. Two independent-samples t text was used for analysis. Results: The germiculture in each group was negative. The difference in polmerization time and CT value of each group were not significant (P>0.05), while the strength and stiffness were significantly different (P<0.05). Conclusions: Sterilized effects of two groups were satisfied but the dry-heat barium sulfate is superior, more suitable for vertebroplasty. (authors)

  7. Interactions between nitrogen molecules and barium atoms on Ru (0001) surface

    International Nuclear Information System (INIS)

    Zhao Xinxin; Mi Yiming; Xu Hongxia; Wang Lili; Ren Li; Tao Xiangming; Tan Mingqiu

    2011-01-01

    We had performed first principles calculations on interactions between nitrogen molecules and barium atoms on Ru (0001) surface using density function theory methods. It was shown that effects of barium atoms weakened the bond strength of nitrogen molecules. The bond length of nitrogen molecule increases from 0.113 nm on Ru (001)-N 2 to 0.120 nm on Ru (001)-N 2 /Ba surface. While stretch vibrational frequency of nitrogen molecule decreased from 2222 cm -1 and charge transfer toward nitrogen molecule increased from 0.3 e to 1.1 e. Charge was mainly translated from 6 s orbitals of barium atoms to 4 d orbitals of substrate, which enhanced the hybridization between 4 d and 2 π orbitals and increased the dipole moment of 5 σ and d π orbitals of nitrogen molecule. The molecular dipole moment of nitrogen molecule was increased by -0.136 e Anstrom. It was suggested that barium had some characters to be an electronic promoter on the process of activating nitrogen molecules on Ru (0001) surface. (authors)

  8. Modified small bowel follow-through using methylcellulose after administration of barium suspension : comparison with conventional series

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Ha, Hyun Kwon; Park, Sung Tae; Yoon, Soo Woong; Kim, Ho Sung; Kim, Sun Mi

    1998-01-01

    To compare modified small bowel follow-through (SBFT) using methylcellulose after the administration of barium suspension with a conventional series. Materials and Methods : In order to evaluate small bowel pathology, modified SBFT was performed in 155 patients during a 15 month period. All patients received 600 mL of methylcellulose ; 98 had taken 250 mL of 40% wt/vol barium suspension and 57 had taken 150 mL of 70% barium. For the group of 98, the barium suspension was prepared by mixing barium powder with water (n=46) or with methylcellulose in(n=52). For comparison with a modified series, 49 patients who underwent conventional SBFT using 500 mL of 40 %wt/vol barium were lso included. Image quality was rated by three radiologists as p oor , f air , g ood , or e xcellent . We analyzed the relationship between image quality, transit time and small bowel pathology;the sensitivity and specificity of each technique was also determined. Results : Among the four techniques, modified SBFT with 250 mL of 40% wt/vol barium suspension, prepared by mixing barium powder with methylcellulose, showed the best image quality ['excellent' result in 33 of the 52 patients (63%)] and shortest transit time to the cecum. The high image quality of this technique was not affected by the presence of small bowel pathology;its use resulted in the lowest incidence and slowest development of flocculation. The sensitivity (91-95%) of the three modified SBFT procedures was superior to that of a conventional series(76%), but there was no difference in specificity.Conclusion : Modified SBFT using methylcellulose after administering barium suspension with barium powder as a mixing agent is a simple technique. Its use easily improves the image quality and diagnostic accuracy of peroral SBFT

  9. Anion and cation diffusion in barium titanate and strontium titanate; Anionen- und Kationendiffusion in Barium- und Strontiumtitanat

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, Markus Franz

    2012-12-19

    Perovskite oxides show various interesting properties providing several technical applications. In many cases the defect chemistry is the key to understand and influence the material's properties. In this work the defect chemistry of barium titanate and strontium titanate is analysed by anion and cation diffusion experiments and subsequent time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reoxidation equation for barium titanate used in multi-layer ceramic capacitors (MLCCs) is found out by a combination of different isotope exchange experiments and the analysis of the resulting tracer diffusion profiles. It is shown that the incorporation of oxygen from water vapour is faster by orders of magnitude than from molecular oxygen. Chemical analysis shows the samples contain various dopants leading to a complex defect chemistry. Dysprosium is the most important dopant, acting partially as a donor and partially as an acceptor in this effectively acceptor-doped material. TEM and EELS analysis show the inhomogeneous distribution of Dy in a core-shell microstructure. The oxygen partial pressure and temperature dependence of the oxygen tracer diffusion coefficients is analysed and explained by the complex defect chemistry of Dy-doped barium titanate. Additional fast diffusion profiles are attributed to fast diffusion along grain boundaries. In addition to the barium titanate ceramics from an important technical application, oxygen diffusion in cubic, nominally undoped BaTiO{sub 3} single crystals has been studied by means of {sup 18}O{sub 2}/{sup 16}O{sub 2} isotope exchange annealing and subsequent determination of the isotope profiles in the solid by ToF-SIMS. It is shown that a correct description of the diffusion profiles requires the analysis of the diffusion through the surface space-charge into the material's bulk. Surface exchange coefficients, space-charge potentials and bulk diffusion coefficients are analysed as a function of oxygen partial

  10. Chemically stable Dy–Y double substituted barium zirconate with high proton conductivity and improved sinterability

    Energy Technology Data Exchange (ETDEWEB)

    Paydar, M.H., E-mail: paaydar@shirazu.ac.ir [Department of Materials Science and Engineering, School of Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Nishimura, Ch. [Hydrogen Materials Unit, Environment and Energy Materials Division, National Institute for Materials Science, Tsukuba, Ibaraki (Japan); Kobayashi, K. [Advanced Ceramics Group, Materials Processing Unit, Advanced Key Technologies Division, National Institute for Materials Science, Tsukuba, Ibaraki (Japan)

    2015-10-05

    Highlights: • BaZr{sub (0.8−x)}Dy{sub x}Y{sub 0.2}O{sub 3−δ} (0 ⩽ x ⩽ 0.2) powders were synthesized by a wet chemical route. • The ability of the synthesized powders in uptaking water was determined. • Chemical stability of the synthesized powders was evaluated under in wet and CO{sub 2} atmosphere. • The conductivity of the sintered pellets was measured by AC impedance spectroscopy. • It was shown that Dy-doped BZY20 ceramic has excellent proton conductivity. • It was proved that Dy-doped BZY20 ceramic has good chemical stability. • It was concluded that Dy-doped BZY20 electrolyte can be considered as a promising electrolyte for solid oxide fuel cell applications. - Abstract: Novel proton conductors BaZr{sub (0.8−x)}Dy{sub x}Y{sub 0.2}O{sub 3−δ} (BZ{sub 0.8−x}D{sub x}Y20, 0 ⩽ x ⩽ 0.2) with high proton conductivity, chemical stability and improved sinterability are developed by partially substituting the Zr site of the 20 mol% Y-doped barium zirconate (BZY20) with Dy. A modified Pechini method was applied to synthesize the BZ{sub 0.8−x}D{sub x}Y20 powders. The X-ray diffraction patterns of the well-calcined powders indicated that the specimens with 0 ⩽ x ⩽ 0.2 possessed a single-phase of cubic perovskite-type oxides. Stability tests under both CO{sub 2} and moist air atmospheres demonstrated that the excellent chemical stability of the base BZY20 material was not influenced by the introduction of Dy. High density pellets with larger grain sizes were obtained at temperatures lower than those commonly employed for the base Y-doped barium zirconate compound. The proton conductivities, measured in different oxidizing and reducing, dry and humidified atmospheres by impedance spectroscopy, were significantly influenced by the Dy amount. In overall, BaZr{sub (0.8−x)}Dy{sub x}Y{sub 0.2}O{sub 3−δ} solid solutions having Dy ∼ 5–10% showed excellent chemical stability and high conductivity (above 10{sup −2} S cm{sup −1} at

  11. Influence of aspheric intraocular lens on frequency doubling technology and contrast sensitivity: a fellow eye study

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2014-12-01

    Full Text Available Purpose: To evaluate whether implantation of an aspheric intraocular lens (IOL results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery and, therefore, changes on frequency-doubling technology (FDT testing. Methods: The present prospective clinical study enrolled 25 patients with bilateral cataract (50 eyes, who randomly received either an aspheric (Akreos AO or a spherical (Akreos Fit IOL in one eye and the other IOL in the second eye. Assessment 12 months postoperatively included photopic and mesopic contrast sensitivity testing. Higher-order aberrations (HOAs were computed. FDT testing was divided into four areas to evaluate the variation of the values at different points. The median values of the local pattern thresholds (median area contrast sensitivity [MACS] obtained with that division were calculated. Results: The Akreos AO group obtained statistically significantly lower values of HOAs and spherical aberration compared with the Akreos Fit group. There was a statistically significant between-group difference in contrast sensitivity under mesopic conditions at all spatial frequencies. No statistically significant differences were observed in mean deviation and pattern standard deviation. The aspheric IOL exhibited higher MACS in all areas, although a statistically significant difference was reached only in the 20-degree field area (P=0.043. Conclusion: Aspheric IOLs significantly reduced spherical aberration and HOAs, improving mesopic contrast sensitivity. Although there was a trend toward slightly improved FDT in the aspheric IOL group, it was not statistically significant.

  12. Esophageal abnormalities in gastroesophageal reflux disease.

    Science.gov (United States)

    Levine, Marc S; Carucci, Laura R

    2018-06-01

    Fluoroscopic esophagography is a widely available, safe, and inexpensive test for detecting gastroesophageal reflux disease. In this article, we review the technique for performing a high-quality esophagram, including upright, double-contrast views of the esophagus and cardia with high-density barium; prone, single-contrast views of the esophagus with low-density barium; and evaluation of gastroesophageal reflux. We then discuss the radiographic findings associated with gastroesophageal reflux disease, including esophageal dysmotility, reflux esophagitis, peptic strictures, and Barrett's esophagus. Finally, we consider the differential diagnosis for the various radiographic findings associated with this condition. When carefully performed and interpreted, the esophagram is a useful test for evaluating gastroesophageal reflux disease and its complications.

  13. Impurities in barium titanate posistor ceramics

    Czech Academy of Sciences Publication Activity Database

    Korniyenko, S. M.; Bykov, I. P.; Glinchuk, M. J.; Laguta, V. V.; Belous, A. G.; Jastrabík, Lubomír

    2000-01-01

    Roč. 239, - (2000), s. 1209-1218 ISSN 0015-0193 Institutional research plan: CEZ:AV0Z1010914 Keywords : barium titanate phase transition * ESR * positive temperature coefficient of resistivity Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.547, year: 2000

  14. Double-contrast imaging of the pharynx in case of dysphagia as the leading symptom. Methodology and diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Feyerabend, T; Schmitt, R; Richter, E; Bohndorf, W

    1989-01-01

    The article explains the value of double-contrast pharyngography in the gradual programme of diagnostic means for clarifying the symptom of dysphagia. The method is simple and quick and well suited as a first screening method before more complicated methods are used. It allows reliable assessment of postoperative or postradiogenic morphology in case of malignant oro- or hypopharynx tumors and thus also is suitable for tumor aftercare programmes. (orig./GDG).

  15. Primary non-Hodgkin lymphoma of the cecum. A case report

    International Nuclear Information System (INIS)

    Kropivnik, M.; Jamar, B.; Cernelc, B.

    2002-01-01

    Background. Primary lymphoma of the colon is rare, constituting 0.4% of primary colonic malignancies and usually involves cecum or rectum. The aim of this paper is to present the role and the importance of double contrast barium enema (DCBE) in the diagnostic process. Case report. A 77 years old male was admitted because of suspected inflammation in the area of total endoprosthesis of the left hip, inserted ten years before. Listeria monocytogenes was isolated from the aspirate and the patient treated with antibiotics. Twenty years ago the patient underwent nephrectomy because of hypernephroma of left kidney. At the time of admission he had sideropenic anaemia and he was febrile. Conclusion. The patient underwent many diagnostic procedures: ultrasound (US), computed tomography (CT), double contrast barium enema, which showed a tumour in the cecum, small bowel follow-through and scintigraphy. The diagnosis of primary non-Hodgkin lymphoma was established by histology after biopsy at colonoscopy. (author)

  16. Gastroesophageal reflux: comparison of barium studies with 24-h pH monitoring

    International Nuclear Information System (INIS)

    Pan, John J.; Levine, Marc S.; Redfern, Regina O.; Rubesin, Stephen E.; Laufer, Igor; Katzka, David A.

    2003-01-01

    Objective: To determine the correlation between massive gastroesophageal reflux (GER) on barium studies and pathologic acid reflux on 24-h pH monitoring. Methods: A search of hospital records from January 1997 to January 2001 revealed 28 patients who underwent both barium studies and 24-h pH monitoring. The radiologic reports were reviewed to determine the presence and degree of GER. Patients with reflux to or above the thoracic inlet either spontaneously or with provocative maneuvers in the recumbent position were classified as having massive reflux, whereas the remaining patients with reflux below the thoracic inlet or no reflux comprised the control group. The pH monitoring reports were also reviewed to determine if pathologic acid reflux was present in the recumbent position. The findings on these studies were then compared to determine the frequency of pathologic acid reflux in the recumbent position on pH monitoring in patients with massive reflux on barium studies compared with the control group. Results: Massive GER was observed on barium studies in 11 (39%) of the 28 patients and reflux below the thoracic inlet or no reflux in the remaining 17 patients (61%) who comprised the control group. All 11 patients (100%) with massive reflux on barium studies had pathologic acid reflux on pH monitoring in the recumbent position compared with six (35%) of 17 patients in the control group (P=0.0009). The pH in the distal esophagus on pH monitoring was less than 4.0 for 13.1% of the recumbent period for patients with massive GER on barium studies compared with 6.2% of the recumbent period for the control group (P=0.0076). Conclusion: Although 24-h pH monitoring remains the gold standard for the detection of GER, our experience suggests that patients with massive reflux on barium studies are so likely to have pathologic acid reflux in the recumbent position that these individuals can be further evaluated and treated for their gastroesophageal reflux disease (GERD

  17. Gastroesophageal reflux: comparison of barium studies with 24-h pH monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Pan, John J.; Levine, Marc S. E-mail: levine@oasis.rad.upenn.edu; Redfern, Regina O.; Rubesin, Stephen E.; Laufer, Igor; Katzka, David A

    2003-08-01

    Objective: To determine the correlation between massive gastroesophageal reflux (GER) on barium studies and pathologic acid reflux on 24-h pH monitoring. Methods: A search of hospital records from January 1997 to January 2001 revealed 28 patients who underwent both barium studies and 24-h pH monitoring. The radiologic reports were reviewed to determine the presence and degree of GER. Patients with reflux to or above the thoracic inlet either spontaneously or with provocative maneuvers in the recumbent position were classified as having massive reflux, whereas the remaining patients with reflux below the thoracic inlet or no reflux comprised the control group. The pH monitoring reports were also reviewed to determine if pathologic acid reflux was present in the recumbent position. The findings on these studies were then compared to determine the frequency of pathologic acid reflux in the recumbent position on pH monitoring in patients with massive reflux on barium studies compared with the control group. Results: Massive GER was observed on barium studies in 11 (39%) of the 28 patients and reflux below the thoracic inlet or no reflux in the remaining 17 patients (61%) who comprised the control group. All 11 patients (100%) with massive reflux on barium studies had pathologic acid reflux on pH monitoring in the recumbent position compared with six (35%) of 17 patients in the control group (P=0.0009). The pH in the distal esophagus on pH monitoring was less than 4.0 for 13.1% of the recumbent period for patients with massive GER on barium studies compared with 6.2% of the recumbent period for the control group (P=0.0076). Conclusion: Although 24-h pH monitoring remains the gold standard for the detection of GER, our experience suggests that patients with massive reflux on barium studies are so likely to have pathologic acid reflux in the recumbent position that these individuals can be further evaluated and treated for their gastroesophageal reflux disease (GERD

  18. Barium and manganese-doped zinc silicate rods prepared by mesoporous template route and their luminescence property

    Science.gov (United States)

    Dang, Lingyan; Tian, Chen; Zhao, Shifeng; Lu, Qingshan

    2018-06-01

    Barium and manganese-doped zinc silicates was prepared under hydrothermal treatment by mesoporous template route employing mesoporous silica as an active template. The sample displays a rod-like morphology with a mean diameter of ∼40 nm and a mean length of ∼450 nm, which inherits the characteristics of mesoporous silica. The individual rods show single crystalline and assemble into bundle-like hierarchical structure along the channels of the mesoporous silica. When barium ions together with manganese ions are co-doped in zinc silicate, the green emission corresponding to manganese ions display a significant enhancement, especially for the sample with the barium doping concentration of 0.08, which indicates that an energy transfer from barium to manganese ions takes place. With further increasing barium concentration from 0.08 to 0.10, the recombination between the defects related to barium and the excitation states of the manganese dominates accompanying non-radiative transitions which can reduce the emission efficiency.

  19. Electronic and chemical properties of barium and indium clusters

    International Nuclear Information System (INIS)

    Onwuagba, B.N.

    1992-11-01

    The ground state electronic and chemical properties of divalent barium and trivalent indium are investigated in a self-consistent manner using the spin-polarized local density approximation in the framework of Density Functional Theory. A jellium model is adopted in the spirit of Gunnarsson and Lundqvist exchange and correlation energies and the calculated properties primarily associated with the s-p orbitals in barium and p orbitals in indium provide deepened insight towards the understanding of the mechanisms to the magic numbers in both clusters. (author). 21 refs, 5 figs

  20. Preparation and characterization of antimony barium composite oxide photocatalysts

    Science.gov (United States)

    Han, X. P.; Yao, B. H.; Pan, Q. H.; Pen, C.; Zhang, C. L.

    2018-01-01

    In this paper, two kinds of antimony barium composite oxide photocatalysts have been prepared by two methods and characterized by XRD and SEM. The photocatalytic activity was evaluated by a photocatalytic reactor and an ultraviolet spectrophotometer. The results showed that-BaSb2O5•4H2O, BaSb2O6 two kinds of antimony barium composite oxide photocatalysts were successfully prepared in this experiment and they showed good photocatalytic properties. In addition, BaSb2O6 morphology showed more regular, microstructure and better catalytic performance.

  1. Preparation and properties of yttria doped tetragonal zirconia polycrystal/Sr-doped barium hexaferrite ceramic composites

    International Nuclear Information System (INIS)

    Wang, Shanshan; Zhang, Chao; Guo, Ruisong; Liu, Lan; Yang, Yuexia; Li, Kehang

    2015-01-01

    Highlights: • The 3Y-TZP/Sr-doped barium ferrite composites were prepared. • The saturation magnetization was improved by 15% with Sr-doping. • The dispersion coefficient p could reflect the microscopic lattice variation. • The composite with x = 0.5 had the maximum fracture toughness of 8.3 MPa m 1/2 . - Abstract: The effects of substitution of Ba 2+ by Sr 2+ on the magnetic property of barium ferrite and addition barium ferrite secondary phase to the 3 mol% yttria-doped tetragonal zirconia polycrystal (3Y-TZP) matrix on the mechanical property of composites were investigated. The Sr-doped barium ferrite (Ba 1−x Sr x Fe 12 O 19 , x = 0, 0.25, 0.50 and 0.75) was synthesized by solid-state reaction in advance. Then 3Y-TZP/20 wt% Sr-doped barium ferrite composites were prepared by means of conventional ceramic method. It was found that a moderate amount of Sr added to barium ferrite could boost the saturation magnetization by 15% compared with the composites without Sr-doping. Besides, the composite with x = 0.50 possessed the best mechanical properties, such as 11.5 GPa for Vickers hardness and 8.3 MPa m 1/2 for fracture toughness, respectively. It was demonstrated that magnetic and mechanical properties of the composites could be harmonized by the incorporation of barium ferrite secondary phase

  2. Measurements of barium photocathode quantum yields at four excimer laser wavelengths

    International Nuclear Information System (INIS)

    Van Loy, M.D.; Young, A.T.; Leung, K.N.

    1992-06-01

    The electron quantum yields from barium cathodes excited by excimer laser radiation at 193, 248, 308, and 351 nm have been determined. Experiments with different cathode surface preparation techniques reveal that deposition of barium film a few microns thick on a clean copper surface under moderate vacuum conditions achieves relatively high quantum efficiencies. Quantum yields measured from surfaces prepared in this manner are 2.3 x 10 -3 at 193 nm, 7.6 x 10 - 4 at 248 nm, 6.1 x 10 -4 at 308 nm, and 4.0 x 10 -4 at 351 nm. Other preparation techniques, such as laser cleaning of a solid barium surface, produced quantum yields that were at least an order of magnitude lower than these values

  3. Obtaining of a barium compound by combustion chemistry and their evaluation as Co adsorbent

    International Nuclear Information System (INIS)

    Rosas G, N.

    2008-01-01

    In this work, barium carbonate synthesized by chemical combustion method using a chemical precursor prepared by the combination of barium nitrate and urea as a fuel, with a 1:1 molar ratio in aqueous solution, the chemical precursor was heated to evaporate excess water, producing a homogeneous viscous liquid, that when heated to 900 centi grades for 5 minutes an exothermic reaction was produced very quickly and abruptly, forming a white powder final product, fine porous, little spongy, dry and crystalline ready to be used as material adsorbent. Additionally, the effect of water on the synthesis by chemical combustion was studied. Simultaneously, and with the purpose of comparing the advantages and disadvantages of the method by chemical combustion, barium carbonate was synthesized by precipitation method using barium nitrate salts and sodium carbonate. Synthesized barium carbonate, was characterized by X-ray diffraction, thermal gravimetric analysis, infrared spectrometry and scanning electron microscopy. We studied the adsorption capacity of Co present in aqueous solution by static tests on materials synthesized at room temperature using the neutron activation analysis. It was found that the synthesis by chemical combustion provides an interesting alternative compared to the synthesis by precipitation because it offers simplicity of synthesis and speed to have a good adsorbent material. It was found that the barium carbonate synthesized by the chemical combustion method using in their synthesis 1.0 ml of water, was the one who achieved the maximum adsorption capacity of 95.6% compared with the barium carbonate prepared by precipitation, which reached a capacity adsorption of 51.48%. (Author)

  4. Photometric Calibration of the Barium Cloud Image in a Space Active Experiment: Determining the Release Efficiency

    International Nuclear Information System (INIS)

    Xie Liang-Hai; Li Lei; Wang Jing-Dong; Tao Ran; Cheng Bing-Jun; Zhang Yi-Teng

    2014-01-01

    The barium release experiment is an effective method to explore the near-earth environment and to study all kinds of space physics processes. The first space barium release experiment in China was successfully carried out by a sounding rocket on April 5, 2013. This work is devoted to calculating the release efficiency of the barium release by analyzing the optical image observed during the experiment. First, we present a method to calibrate the images grey value of barium cloud with the reference stars to obtain the radiant fluxes at different moments. Then the release efficiency is obtained by a curve fitting with the theoretical evolution model of barium cloud. The calculated result is basically consistent with the test value on ground

  5. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  6. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    International Nuclear Information System (INIS)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo

    2012-01-01

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  7. Comparative analysis of double contrast study and endoscopy in early gastric cancer

    International Nuclear Information System (INIS)

    Choi, Young Jin; Chung, Tae Sub; Lee, Jong Tae; Yoo, Hyung Sik

    1987-01-01

    To assess the diagnostic accuracy of the double contrast upper gastrointestinal series (UGI), we have done a retrospective analysis of pathologically proven 92 cases of early gastric cancer (EGC) during the period between March 1981 and February 1986. The results were as follows: 1. The diagnostic accuracy of EGC was 66% on UGI and 62% on fiberscopy. 2. The radiological diagnosis (UGI) of 92 cases was EGC in 61 cases, advanced cancer in 15 cases, cancer invaded in the muscle layer in 7 cases (PM cancer), benign ulcer in 8 cases and polyp in 1 case. 3. The commonest type was type IIc (40%), and the second commonest type was IIc + III. As many EGC's present with ulceration, any ulcerating lesion should be carefully evaluated keeping the possibility of EGC in mind. 4. The rate of lymph node metastasis was 7%, and higher in EGC's with submucosal invasion, in depressed and large lesions

  8. Comparative analysis of double contrast study and endoscopy in early gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Jin; Chung, Tae Sub; Lee, Jong Tae; Yoo, Hyung Sik [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1987-10-15

    To assess the diagnostic accuracy of the double contrast upper gastrointestinal series (UGI), we have done a retrospective analysis of pathologically proven 92 cases of early gastric cancer (EGC) during the period between March 1981 and February 1986. The results were as follows: 1. The diagnostic accuracy of EGC was 66% on UGI and 62% on fiberscopy. 2. The radiological diagnosis (UGI) of 92 cases was EGC in 61 cases, advanced cancer in 15 cases, cancer invaded in the muscle layer in 7 cases (PM cancer), benign ulcer in 8 cases and polyp in 1 case. 3. The commonest type was type IIc (40%), and the second commonest type was IIc + III. As many EGC's present with ulceration, any ulcerating lesion should be carefully evaluated keeping the possibility of EGC in mind. 4. The rate of lymph node metastasis was 7%, and higher in EGC's with submucosal invasion, in depressed and large lesions.

  9. Phantom studies on the artifacts of barium on 18F-FDG DHC/CT images induced by X-ray attenuation correction

    International Nuclear Information System (INIS)

    Wang Wei; Zhu Jiarui; Wang Xinqiang; Zhao Wenrui; Chuan Ling; Xu Genxiang; Gao Chunhua; Fang Tingzheng

    2007-01-01

    Objective: Attenuation correction (AC) based on X-ray transmission map may result in false positive readings or artifacts on PET images, some of them due to the internal residue of high density contrast media used in diagnostic X-ray imaging. The aim of this study was to experimentally estimate the impacts of different concentrations and volumes of barium contrast on X-CT AC (CTAC) for dual-head coincidence (DHC/CT) images. Methods: A cylindrical phantom containing 18 F solution (3.7 kBq/ml), in which plastic fingertips enclosed with different concentrations (0.05, 0.1, 0.2, 0.3, 0.4, 0.5, 1.0, 2.0, 3.0 kg/L)and volumes(0.5, 1.0, 1.5, 2.0, 2.5 ml) of BaSO 4 contrast media were inserted, was used to modulate routine 18 F-fluorodeoxyglucose (FDG) imaging study on a DHC/CT scanner (GE Discovery VH). Sequential 18 F emission and X-CT transmission acquisitions followed by data processing and reconstruction were carried out in clinical settings. For comparison, both visual and quantitative analyses were performed on CTAC and non-AC (NAC) images of the phantom. Results: In NAC images, the radioactivity distribution within the whole phantom was non-uniform with lower counts in the center; the plastic fingertips were all seen as 'cold spots' with much lower counts in the contrast region than in their surrounding areas. On the contrary, in CTAC images, the radioactivity distribution within the whole phantom was almost uniform; while most plastic fingertips with media concentration ≥0.1 kg/L and volume >0.5 ml were all depicted as 'hot spots' with higher counts than in surrounding areas. Conclusions: Barium contrast with relative high concentration or large volume can induce artifacts on CTAC DHC/CT images. In clinical setting, proper interpretation of CTAC DHC/CT images should refer to NAC DHC/CT images to exclude any artifacts related to the contrast media residues. (authors)

  10. Inconceivable Hypokalemia: A Case Report of Acute Severe Barium Chloride Poisoning

    Directory of Open Access Journals (Sweden)

    Haibo Tao

    2016-01-01

    Full Text Available Barium is a heavy divalent alkaline earth metal that has been known as a muscle poison. Barium can cause human toxicity, which may lead to significant hypokalemia and have serious consequences. This paper reports a case of unprecedented barium intoxication in which the patient, who suffered from depression, swallowed at least 3.0 g barium chloride to commit suicide. On admission, the patient presented with nausea, vomiting, stomach burning feeling, dizziness, and weakness. Emergency biochemical testing showed that the patient was suffering from severe hypokalemia (K+ 1.7 mmol/L. His electrocardiogram (ECG prompted atrioventricular blocking, ventricular tachycardia, prolongation of PR interval, ST segment depression with U waves, and T wave inversion. Intravenous potassium supplements were given immediately to correct hypokalemia and regular monitoring of vital signs and fluid balance was arranged. After all-out rescue of our hospital personnel, the condition of the patient is currently stable and he is gradually recovering. This case exemplifies the weaknesses of the management of toxic substances and the lack of mental health education for young people. We hope to get more attention for the supervision of toxic substances and the healthy development of young people.

  11. A Comparative Study on Magnetostructural Properties of Barium Hexaferrite Powders Prepared by Polyethylene Glycol

    OpenAIRE

    Zehra Durmus

    2014-01-01

    Nanocrystalline particles of barium hexaferrite were synthesized by a sol-gel combustion route using nitrate-citrate gels prepared from metal nitrates and citric acid solutions with Fe/Ba molar ratio 12. The present paper aims to study the effect of addition of polyethylene glycol (PEG) solutions with different molecular weights (MW: 400, 2000, and 10.000 g/mol) on magnetostructural properties of barium hexaferrite. The formation of the barium hexaferrite was inspected using X-ray diffractio...

  12. Efficacy of Barium-Based Fecal Tagging for CT Colonography: a Comparison between the Use of High and Low Density Barium Suspensions in a Korean Population - a Preliminary Study

    Science.gov (United States)

    Kim, Min Ju; Lee, Seung Soo; Byeon, Jeong-Sik; Choi, Eugene K.; Kim, Jung Hoon; Kim, Yeoung Nam; Kim, Ah Young; Ha, Hyun Kwon

    2009-01-01

    Objective This preliminarily study was designed to determine and to compare the efficacy of two commercially available barium-based fecal tagging agents for CT colonography (CTC) (high-density [40% w/v] and low-density [4.6% w/v] barium suspensions) in a population in Korea. Materials and Methods In a population with an identified with an average-risk for colorectal cancer, 15 adults were administered three doses of 20 ml 40% w/v barium for fecal tagging (group I) and 15 adults were administered three doses of 200 ml 4.6% w/v barium (group II) for fecal tagging. Excluding five patients in group I and one patient in group II that left the study, ten patients in group I and 14 patients in group II were finally included in the analysis. Two experienced readers evaluated the CTC images in consensus regarding the degree of tagging of stool pieces 6 mm or larger. Stool pieces were confirmed with the use of standardized CTC criteria or the absence of matched lesions as seen on colonoscopy. The rates of complete fecal tagging were analyzed on a per-lesion and a per-segment basis and were compared between the patients in the two groups. Results Per-lesion rates of complete fecal tagging were 52% (22 of 42; 95% CI, 37.7-66.6%) in group I and 78% (28 of 36; 95% CI, 61.7-88.5%) in group II. The difference between the two groups did not reach statistical significance (p = 0.285). The per-segment rates of complete tagging were 33% (6 of 18; 95% CI, 16.1%-56.4%) in group I and 60% (9 of 15; 95% CI, 35.7%-80.3%) in group II; again, the difference between the two groups did not reach statistical significance (p = 0.171). Conclusion Barium-based fecal tagging using both the 40% w/v and the 4.6% w/v barium suspensions showed moderate tagging efficacy. The preliminary comparison did not demonstrate a statistically significant difference in the tagging efficacy between the use of the two tagging agents, despite the tendency toward better tagging with the use of the 4.6% w/v barium

  13. Spectrophotometry of barium, CH, and R-type carbon stars

    International Nuclear Information System (INIS)

    Gow, C.E.

    1976-01-01

    Observations of 35 barium, CH, R, and hydrogen-deficient carbon stars, along with ten comparison K giants, have been made with the Indiana rapid spectrum scanner and the Indiana SIT vidicon spectrometer. The scanner observations cover a wavelength range of 3300--7000 A at 30-A resolution, while the SIT vidicon observations cover a wavelength range of 3800--5000 A at 2.5-A resolution. The data have been used to form molecular indices for a quantitative measurement of the strength of molecular features appearing in this region of the spectrum, and to compare the spectral energy distribution of carbon and oxygen stars over the entire observed wavelength range. We find the C 2 Swan index correlated strongly with both the strength of an unidentified feature centered near 4000 A, and the barium-to-hydrogen ratio. A detailed comparison of the spectral energy distribution of the barium stars with normal K giants shows that this unidentified absorption feature consists of two shallows depressions, one at 4000 A and another at 4325 A

  14. Fine structure of striations observed in barium plasma injections in the magnetospheric cleft

    International Nuclear Information System (INIS)

    Simons, D.J.; Eastman, T.E.; Pongratz, M.B.

    1976-01-01

    In January and November of 1975, the Los Alamos Scientific Laboratory sponsored four high altitude shaped charge barium plasma injections in the magnetospheric cleft region. These experiments were TORDO UNO (January 6), TORDO DOS (January 11), PERIQUITO UNO (November 25), and PERIQUITO DOS (November 28). All four injections took place near 500 km altitude, and optical data were taken from two aircraft and a ground station. The TORDO DOS and the PERIQUITO experiments showed rapid formation of striations (within one minute after injection), and fast horizontal spreading in contrast with TORDO UNO. In PERIQUITO DOS, the debris cloud spread magnetically east-west with a small net northerly motion. TORDO UNO shows very rapid poleward motion, and the remaining two events resulted in magnetically east-west horizontal spreading, with no noticeable poleward motion. Striations observed in the PERIQUITO DOS experiment separate in opposite directions with relative velocities of up to 3 km/sec. These field-aligned structures appear to form in sheets of approximately constant magnetic latitude. Significant spatial variations occur on a scale of less than 200 meters. Spatial frequency power spectra across these striations have been determined at various times. Observations of the debris cloud and the fast barium streak show strong field-aligned coherency of striation fine structure, indicating a field line mapping of transverse electric fields and gradients

  15. The efficacy of steroids for postoperative persistent inflammatory reaction in a patient with barium peritonitis: A case report

    Directory of Open Access Journals (Sweden)

    Hirofumi Kojima

    2017-01-01

    Conclusion: Residual barium in the intraperitoneal cavity causes persistent inflammatory reaction in patients with barium peritonitis. The use of steroids is effective for postoperative persistent inflammation due to the residual barium.

  16. Structure and multiferroic properties of barium hexaferrite ceramics

    International Nuclear Information System (INIS)

    Tan, Guolong; Chen, Xiuna

    2013-01-01

    Simultaneous occurrence of large ferroelectricity and strong ferromagnetism have been observed in barium hexaferrite ceramics. Barium hexaferrite (BaFe 12 O 19 ) powders with hexagonal crystal structure were successfully synthesized in a polymer precursor method using barium acetate and ferric acetylacetonate as the precursors. The powders were pressed into pellets which were sintered into ceramics at 1200 °C and 1300 °C for 1 h. The structure and morphology of the ceramics were examined using X-ray diffraction and field emission scanning electron microscopy. Large spontaneous polarization was observed in the BaFe 12 O 19 ceramics at room temperature, revealing a clear ferroelectric hysteresis loop. The maximum remanent polarization of the BaFe 12 O 19 ceramic was estimated approximately 11.8 μC cm −2 . The FeO 6 octahedron in its perovskite-like hexagonal unit cell and the shift of Fe 3+ off the center of octahedron are suggested to be the origin of the polarization in BaFe 12 O 19 . The BaFe 12 O 19 ceramics also showed strong ferromagnetism at room temperature. - Graphical abstract: Ferroelectric hysteresis loops of BaFe 12 O 19 ceramics measured at a frequency of 120 Hz, which shows that the ceramics sintered at 1200 °C is ferroelectric with P r ∼11.8 μC/cm 2 . Highlights: ► Large ferroelectricity and strong ferromagnetism were observed in barium hexaferrite ceramics. ► The maximum remanent polarization of the BaFe 12 O 19 ceramic was estimated to be 11.8 μC cm −2 . ► The FeO 6 octahedron and off-center shift of Fe 3+ are suggested to be the origin of the polarization.

  17. The reaction between barium and nitrogen in liquid sodium: resistivity studies

    International Nuclear Information System (INIS)

    Addison, C.C.; Creffield, G.K.; Hubberstey, P.; Pulham, R.J.

    1976-01-01

    The reaction of nitrogen with solutions of barium (between 0.34 and 6.89 mol % Ba) in liquid sodium at 573 K has been followed by changes in the electrical resistivity of the liquid. The capillary method has been employed, continuous sampling during reaction being achieved by electromagnetic pumping. The initial solution of nitrogen in the metal, followed by precipitation of barium and nitrogen from sodium as the nitride Ba 2 N, are reflected in the resistivity changes. The solubility of nitrogen in the alloy is a linear function of the barium concentration: S(mol % N) = x/4 (0 <= x <= 6.89 mol % Ba). This and the decrease in resistivity which invariably occurs during the solution process, provides additional information on the nature of solvation of nitrogen in solution in the liquid metal. (author)

  18. Barium variation in Acropora palmata and Montastrea annularis

    Science.gov (United States)

    Pingitore, Nicholas E.; Rangel, Yolanda; Kwarteng, Andrew

    1989-06-01

    The barium contents of Acropora palmata and Montastrea annularis are distinct both in their averages (6 and 9 ppm, respectively) and, more impressively, in their variability (5 to 7 ppm and 6 to 15 ppm). A. palmata contained about 50% more Ba2+ than M. annularis and exhibited more than three times as much variation, as measured by their respective coefficients of variation. In contrast, the means and coefficients of variation of Sr2+ in these groups differed by only 6% and 15%. No obvious environmental or post-depositional causes for the inter-and intra-specific variation of Ba2+ could be found. Previous experiments indicate that the partitioning of Ba2+ into aragonite depends directly on the rate of precipitation. This suggests that Ba2+ does not substitute for Ca2+ but instead is incorporated by occlusion. Since growth rates in A. palmata often exceed those of M. annularis, this appears to be the mechanism which generates higher and more variable concentrations of Ba2+ in A. palmata.

  19. Imaging diagnosis--duodenobiliary reflux of barium sulfate during esophagogastrography in a dog.

    Science.gov (United States)

    Shaikh, Layla; Sharma, Ajay; Secrest, Scott

    2015-01-01

    A 4-year-old Australian cattle dog presented for regurgitation, 2 months after duodenal resection and anastomosis for a perforated duodenal ulcer. Duodenobiliary reflux of barium sulfate suspension was detected during fluoroscopic esophagogastrography. Follow-up radiography 2 hours later demonstrated persistence of the barium in the gallbladder and biliary tree. Ultrasonography showed an open sphincter of Oddi but no other morphological abnormalities with the gallbladder or biliary system. No side effects or bloodwork abnormalities were noted. This is the first case report of duodenobiliary reflux of barium in a dog. The pathophysiology of this phenomenon and its incidence and significance in human medicine are discussed. © 2014 American College of Veterinary Radiology.

  20. The Kerr nonlinearity of the beta-barium borate crystal

    DEFF Research Database (Denmark)

    Bache, Morten; Guo, Hairun; Zhou, Binbin

    2013-01-01

    A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond experime......A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond...

  1. Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.

    Science.gov (United States)

    Naik, D R; Bolia, A; Moore, D J

    1985-01-01

    Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasound but showed only minimal reflux on barium swallow, and one showed minimal reflux on ultrasound but had a negative barium meal result. In two children the ultrasound study was inconclusive. Ultrasound has an important role in the diagnosis and follow up of patients under the age of 5 years with gastro-oesophageal reflux. Images FIG 1 FIG 2 PMID:3924317

  2. Microwave-hydrothermal synthesis of barium strontium titanate nanoparticles

    International Nuclear Information System (INIS)

    Simoes, A.Z.; Moura, F.; Onofre, T.B.; Ramirez, M.A.; Varela, J.A.; Longo, E.

    2010-01-01

    Research highlights: → Barium strontium titanate nanoparticles were obtained by the Hydrothemal microwave technique (HTMW) → This is a genuine technique to obtain nanoparticles at low temperature and short times → Barium strontium titanate free of carbonates with tetragonal structure was grown at 130 o C. - Abstract: Hydrothermal-microwave method (HTMW) was used to synthesize crystalline barium strontium titanate (Ba 0.8 Sr 0.2 TiO 3 ) nanoparticles (BST) in the temperature range of 100-130 o C. The crystallization of BST with tetragonal structure was reached at all the synthesis temperatures along with the formation of BaCO 3 as a minor impurity at lower syntheses temperatures. Typical FT-IR spectra for tetragonal (BST) nanoparticles presented well defined bands, indicating a substantial short-range order in the system. TG-DTA analyses confirmed the presence of lattice OH- groups, commonly found in materials obtained by HTMW process. FE/SEM revealed that lower syntheses temperatures led to a morphology that consisted of uniform grains while higher syntheses temperature consisted of big grains isolated and embedded in a matrix of small grains. TEM has shown BST nanoparticles with diameters between 40 and 80 nm. These results show that the HTMW synthesis route is rapid, cost effective, and could serve as an alternative to obtain BST nanoparticles.

  3. Contrast media. Safety issues and ESUR guidelines. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Dept. of Diagnostic Radiology; Copenhagen Univ., Herlev (Denmark). Dept. of Diagnostic Sciences; Webb, Judith A.W. (eds.) [St. Bartholomew' s Hospital London Univ. (United Kingdom). Dept. of Radiology

    2009-07-01

    In 1994 the European Society of Urogenital Radiology (ESUR) set up a committee to consider the safety of contrast media used for diagnostic imaging. Subsequently the committee questioned members, reviewed the literature, proposed guidelines and discussed these proposals with participants at the annual symposia of the society. The end result of this work was the successful first edition of this book, published in 2006. This second edition not only updates the previous edition, but also contains some completely new chapters, for example on gadolinium-based contrast agents, meta-analyses in contrast media research and various regulatory issues. Comprehensive consideration is given to the many different safety issues relating to iodinated, MR, ultrasound and barium contrast media. The text includes chapters on both acute and delayed non-renal adverse reactions and on renal adverse reactions. All those questions frequently raised in radiological practice are addressed, and the well-known ESUR guidelines on contrast media are included. This book, presented in a handy, easy to use format, provides an invaluable, unique and unparalleled source of information on the safety issues relating to contrast media. (orig.)

  4. Contrast media. Safety issues and ESUR guidelines. 2. rev. ed.

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Copenhagen Univ., Herlev; Webb, Judith A.W.

    2009-01-01

    In 1994 the European Society of Urogenital Radiology (ESUR) set up a committee to consider the safety of contrast media used for diagnostic imaging. Subsequently the committee questioned members, reviewed the literature, proposed guidelines and discussed these proposals with participants at the annual symposia of the society. The end result of this work was the successful first edition of this book, published in 2006. This second edition not only updates the previous edition, but also contains some completely new chapters, for example on gadolinium-based contrast agents, meta-analyses in contrast media research and various regulatory issues. Comprehensive consideration is given to the many different safety issues relating to iodinated, MR, ultrasound and barium contrast media. The text includes chapters on both acute and delayed non-renal adverse reactions and on renal adverse reactions. All those questions frequently raised in radiological practice are addressed, and the well-known ESUR guidelines on contrast media are included. This book, presented in a handy, easy to use format, provides an invaluable, unique and unparalleled source of information on the safety issues relating to contrast media. (orig.)

  5. Carbon nanotubes allow capture of krypton, barium and lead for multichannel biological X-ray fluorescence imaging.

    Science.gov (United States)

    Serpell, Christopher J; Rutte, Reida N; Geraki, Kalotina; Pach, Elzbieta; Martincic, Markus; Kierkowicz, Magdalena; De Munari, Sonia; Wals, Kim; Raj, Ritu; Ballesteros, Belén; Tobias, Gerard; Anthony, Daniel C; Davis, Benjamin G

    2016-10-26

    The desire to study biology in situ has been aided by many imaging techniques. Among these, X-ray fluorescence (XRF) mapping permits observation of elemental distributions in a multichannel manner. However, XRF imaging is underused, in part, because of the difficulty in interpreting maps without an underlying cellular 'blueprint'; this could be supplied using contrast agents. Carbon nanotubes (CNTs) can be filled with a wide range of inorganic materials, and thus can be used as 'contrast agents' if biologically absent elements are encapsulated. Here we show that sealed single-walled CNTs filled with lead, barium and even krypton can be produced, and externally decorated with peptides to provide affinity for sub-cellular targets. The agents are able to highlight specific organelles in multiplexed XRF mapping, and are, in principle, a general and versatile tool for this, and other modes of biological imaging.

  6. Recovery and separation of rare-earth elements, barium, and strontium from bastnasite with sulfuric acid

    International Nuclear Information System (INIS)

    Eisele, J.A.; Bauer, D.J.

    1974-01-01

    A bench-scale investigation was made of a concentrated H 2 SO 4 reaction for recovering and separating rare earth elements, barium, and strontium from a bastnaesite ore and byproduct. Barium and strontium were dissolved in the concentrated acid and precipitated as a mixed product by water dilution. Separation of strontium from barium was effected by reaction with Na 2 CO 3 solution, followed by a dilute acid leach of the SrCO 3 formed. After removing the barium and strontium from bastnaesite ore, the rare-earth elements were roasted to water-soluble sulfates. The rare earth sulfate solution was subsequently processed by solvent extraction to produce rare-earth oxides low in lead and magnesium. (U.S.)

  7. Comparison of Calcium and Barium Microcapsules as Scaffolds in the Development of Artificial Dermal Papillae.

    Science.gov (United States)

    Liu, Yang; Lin, Changmin; Zeng, Yang; Li, Haihong; Cai, Bozhi; Huang, Keng; Yuan, Yanping; Li, Yu

    2016-01-01

    This study aimed to develop and evaluate barium and calcium microcapsules as candidates for scaffolding in artificial dermal papilla. Dermal papilla cells (DPCs) were isolated and cultured by one-step collagenase treatment. The DPC-Ba and DPC-Ca microcapsules were prepared by using a specially designed, high-voltage, electric-field droplet generator. Selected microcapsules were assessed for long-term inductive properties with xenotransplantation into Sprague-Dawley rat ears. Both barium and calcium microcapsules maintained xenogenic dermal papilla cells in an immunoisolated environment and induced the formation of hair follicle structures. Calcium microcapsules showed better biocompatibility, permeability, and cell viability in comparison with barium microcapsules. Before 18 weeks, calcium microcapsules gathered together, with no substantial immune response. After 32 weeks, some microcapsules were near inflammatory cells and wrapped with fiber. A few large hair follicles were found. Control samples showed no marked changes at the implantation site. Barium microcapsules were superior to calcium microcapsules in structural and mechanical stability. The cells encapsulated in hydrogel barium microcapsules exhibited higher short-term viability. This study established a model to culture DPCs in 3D culture conditions. Barium microcapsules may be useful in short-term transplantation study. Calcium microcapsules may provide an effective scaffold for the development of artificial dermal papilla.

  8. Are the tolerabilities of nonionic contrast media identical? Outcome of a double-blind, randomized multicentre study with Iomeprol and lopromide

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1997-01-01

    Since a larger number of nonionic contrast media is available for the radiologist, the question arises as to whether they differ in their clinical tolerability. A double-blind, randomized, two-group comparison of phase IV with Iomeprol and Iopromide was carried out at 6 hospitals involving a total of 1.200 patients with the indication for computed tomography. The contrast media doses and the flow in computed tomography of the skull, thorax, and abdomen were, depending on the centre, between 50 and 200 ml and 0.5 to 3.0 ml/s, respectively. The biostatistical evaluation of adverse events which were probably contrast medium-related produced a highly significant difference between the two contrast media in favor of Iomeprol (p=0.0005). The difference in the reactions of heat, nausea, and vomiting is of clinical relevance as such adverse events may negatively affect the examination procedure and the opacification in spiral computed tomography. (orig.) [de

  9. Fluoroscopy-guided barium marking for localizing small pulmonary lesions before video-assisted thoracoscopic surgery

    International Nuclear Information System (INIS)

    Yamada, Takahiro; Koyama, Yasunori; Masui, Asami

    2009-01-01

    Small pulmonary lesions not previously seen on chest radiographs will likely be detected with increasing frequency because of the spread of CT screening. For the diagnosis and treatment of such lesions, we frequently perform resection by video-assisted thoracoscopic surgery (VATS). We performed fluoroscopy-guided barium marking for localization of small peripheral pulmonary lesions before VATS resection, and examined its reliability, safety, and usefulness. We studied 46 patients with peripheral pulmonary lesions 20 mm or less in diameter who were scheduled to undergo VATS resection. The average diameter of the lesions was 10.2±0.5 mm (mean±standard error), and the average distance from the pleural surface was 10.1±0.8 mm. The optimal site for the catheter tip was decided on chest radiographs using CT scans for reference beforehand, and a catheter was inserted bronchoscopically into the target segment and guided to the presumed lesion. A 50% (weight/volume) barium sulfate suspension was instilled into the bronchus through the catheter, and the site of barium marking was checked by CT scanning. The average instilled volume of barium was 0.36±0.03 ml. On CT scans, barium spots were superimposed on the target lesions in 35 of the 46 patients and were only 15 mm from the lesions in the other patients. Barium was well recognized in all patients at the time of VATS resection, and we could confirm the diagnosis in all patients. A mild cough persisted for about 1 week in 1 patient, but the other patients had no specific complications. Fluoroscopy-guided barium marking is a safe, convenient, and reliable method for localization of small pulmonary lesions before VATS resection. (author)

  10. How invasive is TMJ double-contrast arthrography in combination with cinematography? Patient discomfort versus known diagnostic gain.

    Science.gov (United States)

    Engelke, W; Mommaerts, M

    1990-04-01

    There is no doubt that double-contrast TMJ fluoroscopic tomography enables a differential diagnosis and treatment in internal derangement pathosis. Its indication is, apart from the expected diagnostic gain, also determined by the degree of its invasiveness, and other alternative diagnostics being available (nuclear magnetic resonance). Data on patient discomfort and complications were gathered in 63 arthrotomographies; pain sensations and mandibular mobility, during and after the procedure in particular, were studied. We consider, along with Westesson, the procedure to be less invasive than commonly considered, once the surgeon-radiologist has gained enough experience.

  11. Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique – feasibility study

    International Nuclear Information System (INIS)

    Baxa, Jan; Vendiš, Tomáš; Moláček, Jiří; Štěpánková, Lucie; Flohr, Thomas; Schmidt, Bernhard; Korporaal, Johannes G.; Ferda, Jiří

    2014-01-01

    Purpose: To verify the technical feasibility of low contrast volume (40 mL) run-off CT angiography (run-off CTA) with the individual scan time optimization based on double-level test bolus technique. Materials and methods: A prospective study of 92 consecutive patients who underwent run-off CTA performed with 40 mL of contrast medium (injection rate of 6 mL/s) and optimized scan times on a second generation of dual-source CT. Individual optimized scan times were calculated from aortopopliteal transit times obtained on the basis of double-level test bolus technique – the single injection of 10 mL test bolus and dynamic acquisitions in two levels (abdominal aorta and popliteal arteries). Intraluminal attenuation (HU) was measured in 6 levels (aorta, iliac, femoral and popliteal arteries, middle and distal lower-legs) and subjective quality (3-point score) was assessed. Relations of image quality, test bolus parameters and arterial circulation involvement were analyzed. Results: High mean attenuation (HU) values (468; 437; 442; 440; 342; 274) and quality score in all monitored levels was achieved. In 91 patients (0.99) the sufficient diagnostic quality (score 1–2) in aorta, iliac and femoral arteries was determined. A total of 6 patients (0.07) were not evaluable in distal lower-legs. Only the weak indirect correlation of image quality and test-bolus parameters was proved in iliac, femoral and popliteal levels (r values: −0.263, −0.298 and −0.254). The statistically significant difference of the test-bolus parameters and image quality was proved in patients with occlusive and aneurysmal disease. Conclusion: We proved the technical feasibility and sufficient quality of run-off CTA with low volume of contrast medium and optimized scan time according to aortopopliteal transit time calculated from double-level test bolus

  12. Colonic transit time in patient with slow-transit constipation: Comparison of radiopaque markers and barium suspension method

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huimin [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China); Department of General Surgery, Weifang People' s Hospital, ShanDong Province 261041 (China); Han Jiagang [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China); Na Ying [Department of Medical Imaging, Weifang People' s Hospital, ShanDong Province 261041 (China); Zhao Bo; Ma Huachong [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China); Wang Zhenjun, E-mail: wang3zj@sohu.com [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China)

    2011-08-15

    Background: Colonic transit study provides valuable information before surgical treatment is considered for patient with constipation. The radiopaque markers method is the most common way for evaluating colon transit time. The aim of this study is to compare the barium suspension with the radiopaque makers to assess the colonic mobility in patient with constipation. Methods: Colonic transit time was measured in 11 female patients with slow-transit constipation using both radiopaque markers and barium suspension method. In radiopaque markers method, the patient ingested 20 markers on the first day, and an abdominal radiograph was performed every 24 h until 80% markers were excreted. In barium suspension method, the patient swallowed up to 50 ml of 200% (w/v) barium meal. The abdominal radiographs were taken at the same time point as the former. Results: The total or segmental colonic transit time were obviously prolonged in all patients. Segmental transits time spent in the right colon, left colon and rectosigmoid for radiopaque markers and barium suspension method was, respectively, 30 {+-} 6 h and 34 {+-} 7 h; 38 {+-} 9 h and 32 {+-} 6 h; 40 {+-} 8 h and 38 {+-} 10 h. In the radiopaque markers method, total colonic transit time was 108 {+-} 14 h and it was 103 {+-} 13 h in the barium suspension method (P > 0.05). Conclusion: The barium suspension and radiopaque markers gave the similar results for colonic transit time. The barium suspension was a simple and cheap method for evaluating the colonic mobility.

  13. Monte Carlo estimation for pediatric barium meal procedures

    International Nuclear Information System (INIS)

    Filipov, D.; Schelin, H.R.; Denyak, V.; Legnani, A.; Ledesma, J.A.; Paschuk, S.A.; Sauzen, J.; Yagui, A.; Hoff, G.; Khoury, H.J.

    2015-01-01

    Fluoroscopic barium meal (BM) series involve an X-ray examination of the esophagus, stomach, and duodenum, by the use of a contrast media – the barium sulfate (BaSO4). They are widely used to observe digestive functions or to diagnose abnormalities such as ulcers; tumors; inflammation of the esophagus, stomach, and duodenum; malrotations; vascular rings; and gastroesophageal reflux disease (a common ailment in children). However, this procedure uses long fluoroscopy times and multiple radiographies, resulting in high effective doses to pediatric patients, whose radiosensitivity and life expectancy are higher than in adults. Based on those data, the aims of the current study are to: determine the P K,A (kerma-area product) values, on the patient chest area, and the effective doses to 5 and 10 years old children. Thirty-seven different pediatric patients were studied and stratified into two group sizes: 5 and 10 years old. For each procedure, the following data was recorded: sex, age and upper chest thickness, from the patients; technical parameters of the procedure (kV, fluoroscopy time and number of radiographies); distances (focus-detector and focus-table) and field size on the examination table. Three pairs of LiF:Mg,Ti thermoluminescent dosimeters were positioned at the center of the child´s sternum. After that, upper chest thickness was subtracted from focus-table distance, so focus-patient distance was obtained. Using the field size on the table and applying similar triangles concepts, the field size on the patient was measured, which was multiplied by the mean kerma (from the dosimeters), so that P K,A could be determined. To estimate the effective dose, P K,A and technical parameters of the procedure (kV, total filtration, focus-detector distance and field size on the patient) were written in a Monte Carlo software simulation. The results of P K,A and effective doses were higher than studies used for comparison, which shows the importance of an

  14. Electromagnetic properties of photodefinable barium ferrite polymer composites

    Science.gov (United States)

    Sholiyi, Olusegun; Lee, Jaejin; Williams, John D.

    2014-07-01

    This article reports the magnetic and microwave properties of a Barium ferrite powder suspended in a polymer matrix. The sizes for Barium hexaferrite powder are 3-6 μm for coarse and 0.8-1.0 μm for the fine powder. Ratios 1:1 and 3:1 (by mass) of ferrite to SU8 samples were characterized and analyzed for predicting the necessary combinations of these powders with SU8 2000 Negative photoresist. The magnetization properties of these materials were equally determined and were analyzed using Vibrating Sample Magnetometer (VSM). The Thru, Reflect, Line (TRL) calibration technique was employed in determining complex relative permittivity and permeability of the powders and composites with SU8 between 26.5 and 40 GHz.

  15. Electromagnetic properties of photodefinable barium ferrite polymer composites

    Directory of Open Access Journals (Sweden)

    Olusegun Sholiyi

    2014-07-01

    Full Text Available This article reports the magnetic and microwave properties of a Barium ferrite powder suspended in a polymer matrix. The sizes for Barium hexaferrite powder are 3–6 μm for coarse and 0.8–1.0 μm for the fine powder. Ratios 1:1 and 3:1 (by mass of ferrite to SU8 samples were characterized and analyzed for predicting the necessary combinations of these powders with SU8 2000 Negative photoresist. The magnetization properties of these materials were equally determined and were analyzed using Vibrating Sample Magnetometer (VSM. The Thru, Reflect, Line (TRL calibration technique was employed in determining complex relative permittivity and permeability of the powders and composites with SU8 between 26.5 and 40 GHz.

  16. NASA/Max Planck Institute Barium Ion Cloud Project.

    Science.gov (United States)

    Brence, W. A.; Carr, R. E.; Gerlach, J. C.; Neuss, H.

    1973-01-01

    NASA and the Max Planck Institute for Extraterrestrial Physics (MPE), Munich, Germany, conducted a cooperative experiment involving the release and study of a barium cloud at 31,500 km altitude near the equatorial plane. The release was made near local magnetic midnight on Sept. 21, 1971. The MPE-built spacecraft contained a canister of 16 kg of Ba CuO mixture, a two-axis magnetometer, and other payload instrumentation. The objectives of the experiment were to investigate the interaction of the ionized barium cloud with the ambient medium and to deduce the properties of electric fields in the proximity of the release. An overview of the project is given to briefly summarize the organization, responsibilities, objectives, instrumentation, and operational aspects of the project.

  17. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    Science.gov (United States)

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  18. Development of a technique for contrast radiographic examination of the gastrointestinal tract in ball pythons (Python regius).

    Science.gov (United States)

    Banzato, Tommaso; Russo, Elisa; Finotti, Luca; Zotti, Alessandro

    2012-07-01

    To develop a technique for radiographic evaluation of the gastrointestinal tract in ball pythons (Python regius). 10 ball python cadavers (5 males and 5 females) and 18 healthy adult ball pythons (10 males and 8 females). Live snakes were allocated to 3 groups (A, B, and C). A dose (25 mL/kg) of barium sulfate suspension at 3 concentrations (25%, 35%, and 45% [wt/vol]) was administered through an esophageal probe to snakes in groups A, B, and C, respectively. Each evaluation ended when all the contrast medium had reached the large intestine. Transit times through the esophagus, stomach, and small intestine were recorded. Imaging quality was evaluated by 3 investigators who assigned a grading score on the basis of predetermined criteria. Statistical analysis was conducted to evaluate differences in quality among the study groups. The esophagus and stomach had a consistent distribution pattern of contrast medium, whereas 3 distribution patterns of contrast medium were identified in the small intestine, regardless of barium concentration. Significant differences in imaging quality were detected among the 3 groups. Radiographic procedures were tolerated well by all snakes. The 35% concentration of contrast medium yielded the best imaging quality. Use of contrast medium for evaluation of the cranial portion of the gastrointestinal tract could be a reliable technique for the diagnosis of gastrointestinal diseases in ball pythons. However, results of this study may not translate to other snake species because of variables identified in this group of snakes.

  19. Determination of barium in surface and ground waters at Centro Experimental Aramar area

    Energy Technology Data Exchange (ETDEWEB)

    Matoso, Erika, E-mail: ematoso@hotmail.com [Centro Tecnologico da Marinha em Sao Paulo (CEA/CTMS), Ipero, SP (Brazil). Centro Experimental Aramar; Cadore, Solange, E-mail: cadore@iqm.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Instituto de Quimica. Departamento de Quimica Analica

    2015-07-01

    Barium can be found in waters up to 1 mg L{sup -1} and came from natural sources such as sedimentary rocks erosion rich in feldspar and barite. Also anthropogenic activities can release this element such as oil and gas industry, agricultural defensives, chemical industry and waste disposal. At high doses, barium can be harmful to human central nervous system and can also cause high blood pressure, heart problems, fatigue and anxiety. The water potability defined by Brazilian's Ministry of Healthy sets barium concentration up to 0.7 mg L{sup -1} and official regulation defines the same limit of this element to superficial waters (according CONAMA resolution 357/2005) and ground waters (Sao Paulo state regulation). In this work, barium was analyzed monthly in superficial waters from 4 different sampling locations, located in a ratio of 10-km-long from Centro Experimental Aramar (CEA) at Ipanema River, during one year, in order to evaluate the river in different conditions (seasons, temperature and rain period). The ground water was collected every six months. The analytical technique applied was ICP OES and the method conditions were optimized: wavelength, linearity, signal background ratio, detection and quantification limits. Data obtained in this work will contribute to evaluate the presence of barium at CEA region and nearby in order to compare it with current Brazilian regulations. (author)

  20. Determination of barium in surface and ground waters at Centro Experimental Aramar area

    International Nuclear Information System (INIS)

    Matoso, Erika; Cadore, Solange

    2015-01-01

    Barium can be found in waters up to 1 mg L -1 and came from natural sources such as sedimentary rocks erosion rich in feldspar and barite. Also anthropogenic activities can release this element such as oil and gas industry, agricultural defensives, chemical industry and waste disposal. At high doses, barium can be harmful to human central nervous system and can also cause high blood pressure, heart problems, fatigue and anxiety. The water potability defined by Brazilian's Ministry of Healthy sets barium concentration up to 0.7 mg L -1 and official regulation defines the same limit of this element to superficial waters (according CONAMA resolution 357/2005) and ground waters (Sao Paulo state regulation). In this work, barium was analyzed monthly in superficial waters from 4 different sampling locations, located in a ratio of 10-km-long from Centro Experimental Aramar (CEA) at Ipanema River, during one year, in order to evaluate the river in different conditions (seasons, temperature and rain period). The ground water was collected every six months. The analytical technique applied was ICP OES and the method conditions were optimized: wavelength, linearity, signal background ratio, detection and quantification limits. Data obtained in this work will contribute to evaluate the presence of barium at CEA region and nearby in order to compare it with current Brazilian regulations. (author)

  1. 75 FR 20625 - Barium Chloride From China

    Science.gov (United States)

    2010-04-20

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-149 (Third Review)] Barium Chloride From China AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: April 9, 2010. FOR FURTHER INFORMATION CONTACT: Amy Sherman (202-205-3289...

  2. Rheological properties of potassium barium borate glasses

    NARCIS (Netherlands)

    Szwejda, K.A.; Vogel, D.L.; Stevels, J.M.

    1973-01-01

    Several series of potassium barium borate glasses have been investigated as to their rheological properties. It has been found, that all these glasses show deviations from ‘Newtonian’ behaviour below temperatures corresponding to viscosities of 1010 poises. The activation energies of viscous flow

  3. Case report

    African Journals Online (AJOL)

    raoul

    2011-12-18

    Dec 18, 2011 ... 3. Figures. Figure 1: Contrast barium radiography showing an obstructed third part of the duodenum . Proximal to the obstruction a dilated duodenal bulb and stomach was found: classically known as “double bubble” sign. References. 1. Zyromski NJ, Sandoval JA, Pitt HA, Ladd AP, Fogel EL, Mattar WE, ...

  4. Evaluation of radiological findings of complete gastric erosions

    International Nuclear Information System (INIS)

    Jung, Hyun Sub; Choi, See Sung; Lim, Yeo Sub; Kim, Byung Chan; Chung, Young Sun; Kim, Chang Guhn; Won, Jong Jin

    1987-01-01

    The double-contrast upper gastrointestinal (UGI) examination is an effective means of clearly demonstrating complete gastric erosions. The main radiographic feature of the complete gastric erosion is a small barium fleck surrounded by a radiolucent halo in the gastric mucosa. From Jan. 1984 to Dec. 1986 a total of 48 cases of complete gastric erosions was diagnosed by double-contrast UGI examinations, and then 12 cases among them underwent endoscopy within 6 days of UGI examination. For evaluation of the relationship of the diameters of radiolucent halos to the central barium flecks, the radiographic findings were reviewed. 1. 1) The male to female ratio was 20:28. The age of patients ranged from 15 to 76 years, and the most common age group was 6th decade. 2) The clinical symptoms included epigastralgia (63%), indigestion, hunger pain, and vomiting. 2. Thirteen coexistent diseases were found in 11 patients (22.9%): gastric ulcer in 4 patients, duodenal ulcer in 3, gastric cancer in 3, liver cirrhosis in 2, and hepatoma in one. 3. The gastric antrum was involved in all cases. The gastric body was also involved in 8 case, and duodenal bulb in 2 cases. 4. In all cases there were multiple complete erosions. The number of the erosions were 2 to 10 in 83.4% of cases. The radiographic findings of 330 complete erosions in the 48 cases were analyzed. 1) The diameters of surrounding halos varied from 3 to 11mm, and the sized of the central barium flecks from 0(No central barium fleck) to 5mm. The shapes of central barium flecks were round in 70.6% of complete erosions. 2) In general, the small central barium flecks had small surrounding halos, and the large ones large halos (correlation coefficient r=0.97). But with the enlargement of central barium flecks, the ratios of the diameters of surrounding halos to the size of central barium flecks tended to decrease by degrees. It appears that in the formation of a surrounding mucosal elevation (radiolucent halo) of a complete

  5. Evaluation of radiological findings of complete gastric erosions

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hyun Sub; Choi, See Sung; Lim, Yeo Sub; Kim, Byung Chan; Chung, Young Sun; Kim, Chang Guhn; Won, Jong Jin [College of Medicine, Wonkwang University, Iksan (Korea, Republic of)

    1987-06-15

    The double-contrast upper gastrointestinal (UGI) examination is an effective means of clearly demonstrating complete gastric erosions. The main radiographic feature of the complete gastric erosion is a small barium fleck surrounded by a radiolucent halo in the gastric mucosa. From Jan. 1984 to Dec. 1986 a total of 48 cases of complete gastric erosions was diagnosed by double-contrast UGI examinations, and then 12 cases among them underwent endoscopy within 6 days of UGI examination. For evaluation of the relationship of the diameters of radiolucent halos to the central barium flecks, the radiographic findings were reviewed. 1. 1) The male to female ratio was 20:28. The age of patients ranged from 15 to 76 years, and the most common age group was 6th decade. 2) The clinical symptoms included epigastralgia (63%), indigestion, hunger pain, and vomiting. 2. Thirteen coexistent diseases were found in 11 patients (22.9%): gastric ulcer in 4 patients, duodenal ulcer in 3, gastric cancer in 3, liver cirrhosis in 2, and hepatoma in one. 3. The gastric antrum was involved in all cases. The gastric body was also involved in 8 case, and duodenal bulb in 2 cases. 4. In all cases there were multiple complete erosions. The number of the erosions were 2 to 10 in 83.4% of cases. The radiographic findings of 330 complete erosions in the 48 cases were analyzed. 1) The diameters of surrounding halos varied from 3 to 11mm, and the sized of the central barium flecks from 0(No central barium fleck) to 5mm. The shapes of central barium flecks were round in 70.6% of complete erosions. 2) In general, the small central barium flecks had small surrounding halos, and the large ones large halos (correlation coefficient r=0.97). But with the enlargement of central barium flecks, the ratios of the diameters of surrounding halos to the size of central barium flecks tended to decrease by degrees. It appears that in the formation of a surrounding mucosal elevation (radiolucent halo) of a complete

  6. Investigation on the effects of milling atmosphere on synthesis of barium ferrite/magnetite nanocomposite

    NARCIS (Netherlands)

    Molaei, M.J.; Ataie, A.; Raygan, S.; Picken, S.J.

    2011-01-01

    In this research, barium ferrite /magnetite nanocomposites synthesized via a mechano-chemical route. Graphite was used in order to reduce hematite content of barium ferrite to magnetite to produce a magnetic nanocomposite. The effects of processing conditions on the powder characteristics were

  7. Contrast enhancement of microsphere-assisted super-resolution imaging in dark-field microscopy

    Science.gov (United States)

    Zhou, Yi; Tang, Yan; Deng, Qinyuan; Zhao, Lixin; Hu, Song

    2017-08-01

    We report a method of boosting the imaging contrast of microsphere-assisted super-resolution visualization by utilizing dark-field illumination (DFI). We conducted experiments on both 10-µm-diameter silica (SiO2) microspheres with refractive index n ∼ 1.46 under no and partial immersion in ethyl alcohol (n ∼ 1.36) and 20-µm-diameter barium titanate glass (BTG, n ∼ 1.9) microspheres with full immersion to show the super-resolution capability. We experimentally demonstrated that the imaging contrast and uniformity were extraordinarily improved in the DFI mode. The intensity profiles in the visualization also numerically confirm the enhanced sharpness for a better imaging quality when applying DFI.

  8. Correlation between Timed Barium Esophagogram and the Eckardt Stage in Achalasia

    Directory of Open Access Journals (Sweden)

    Waraporn Boonsomjint, M.D.

    2018-01-01

    Full Text Available Objective: To evaluate the correlation of timed barium esophagogram (TBE parameters and the Eckardt stage in patients with achalasia. Methods: This prospective study was done in 29 adult achalasia patients who underwent TBE and were assessed for clinical symptoms according to the Eckardt stage. The association between the Eckardt stage and TBE parameters including the height and the width of barium column, esophageal emptying between 1 and 5 minutes, which was calculated by comparing the area of barium column and esophageal emptying between 0 and 5 minutes, which was calculated from the relative changes in ingested volume to estimated volume of barium column on the 5-min image and this was calculated by using Kruskal-Wallis test. Comparison of mean emptied volume at 1 min. image and mean emptied volume between 1 and 5 minutes was done by using paired samples t-tests. Results: There was a significant difference in the amount of emptied volume at 1 min image (mean = 118.27, SD = 31.1 and emptied volume between 1 min and 5 min images (mean = 11.41, SD = 9.4; t(27 =15.375, p < 0.001. Statistically significant difference in esophageal emptying between 1 and 5 minutes across the Eckardt stages was found (H=8.115, 3 d.f., p=0.044. The difference was statistically significant between the Eckardt stage 2 and 3 (p=0.039. There were no statistically significant differences in other TBE parameters across the Eckardt stages. Conclusion: No statistically significant difference in TBE parameters across the Eckardt stages was found in the present study. However, TBE is a useful objective method to assess esophageal emptying in patients with achalasia. Interpretation of TBE should be standardized. Calculation of esophageal emptying should include the amount of barium emptied from the esophagus in the first minute.

  9. The effect of barium temperature on esophageal and castric motility in dogs: a fluoroscopic study

    International Nuclear Information System (INIS)

    Eville, P.; Ackerman, N.

    1984-01-01

    The influence of barium temperature on canine esophageal transit time and gastric motility were studied fluoroscopically. Micropulverized barium sulfate (30% wt/vol) at 35°F, 70°F, and 100°F was given orally to each of five dogs with a minimum of two hours between each temperature. Esophageal transit times ranged from 4 to 9.67 seconds, and gastric contractions average four per minute. Barium temperature had no significant effect on either esophageal transit time or gastric motility

  10. Colonic transit time in patient with slow-transit constipation: Comparison of radiopaque markers and barium suspension method

    International Nuclear Information System (INIS)

    Xu Huimin; Han Jiagang; Na Ying; Zhao Bo; Ma Huachong; Wang Zhenjun

    2011-01-01

    Background: Colonic transit study provides valuable information before surgical treatment is considered for patient with constipation. The radiopaque markers method is the most common way for evaluating colon transit time. The aim of this study is to compare the barium suspension with the radiopaque makers to assess the colonic mobility in patient with constipation. Methods: Colonic transit time was measured in 11 female patients with slow-transit constipation using both radiopaque markers and barium suspension method. In radiopaque markers method, the patient ingested 20 markers on the first day, and an abdominal radiograph was performed every 24 h until 80% markers were excreted. In barium suspension method, the patient swallowed up to 50 ml of 200% (w/v) barium meal. The abdominal radiographs were taken at the same time point as the former. Results: The total or segmental colonic transit time were obviously prolonged in all patients. Segmental transits time spent in the right colon, left colon and rectosigmoid for radiopaque markers and barium suspension method was, respectively, 30 ± 6 h and 34 ± 7 h; 38 ± 9 h and 32 ± 6 h; 40 ± 8 h and 38 ± 10 h. In the radiopaque markers method, total colonic transit time was 108 ± 14 h and it was 103 ± 13 h in the barium suspension method (P > 0.05). Conclusion: The barium suspension and radiopaque markers gave the similar results for colonic transit time. The barium suspension was a simple and cheap method for evaluating the colonic mobility.

  11. Study of the dielectric properties of barium titanate-polymer composites

    International Nuclear Information System (INIS)

    Pant, H.C.; Patra, M.K.; Verma, Aditya; Vadera, S.R.; Kumar, N.

    2006-01-01

    A comparative study of complex dielectric properties has been carried out at the X-band of microwave frequencies of composites of barium titanate (BaTiO 3 ) with two different polymer matrices: insulating polyaniline (PANI) powder (emeraldine base) and maleic resin. From these studies, it is observed that the composites of BaTiO 3 with maleic resin show normal composite behavior and the dielectric constant follows the asymmetric Bruggeman model. In contrast, the composites of BaTiO 3 with PANI show an unusual behavior wherein even at a low concentration of PANI (5 wt.%) there is a drastic reduction in the dielectric constant of BaTiO 3 . This behavior of the dielectric constant is explained on the basis of coating of BaTiO 3 particles by PANI which in turn is attributed to the highly surface adsorbing character. The materials have also been characterized using Fourier transform infrared spectroscopy, powder X-ray diffraction, scanning electron microscopy and optical microscopy studies

  12. Barium diffusion in metallo-organic solution deposited barrier layers and Y1Ba2Cu3O7-x films

    International Nuclear Information System (INIS)

    Lipeles, R.A.; Leung, M.S.; Thiede, D.A.

    1990-01-01

    This paper reports on barium silicate and barium aluminate films that were studied for use as chemical reaction and diffusion barrier layers for Y 1 Ba 2 Cu 3 O 7-x (YBC) deposited on sapphire and fused silica substrates by the sol-gel technique. Depth profiling by secondary ion mass spectrometry (SIMS) was used to characterize the abruptness of the interfaces between the barrier layer and the YBC film as well as the barrier layer and the substrate. The authors found that barium aluminate films reacted with fused silica substrates forming a coarse-grained barium silicate phase. Barium silicate, BaSiO 3 , also reacted with silica substrates forming a broad, amorphous reaction zone containing some BaSi 2 O 5 . Although barium silicate and barium aluminate deposited on sapphire formed a BaAl 12 O 19 phase, they provided a barrier to barium diffusion from sol-gel deposited YBC. Crystalline barium aluminate grown on c-cut sapphire was the most effective barrier layer for the growth of YBC films; compositionally uniform YBC films were made similar to that grown on strontium titanate substrates. These data show that chemically stable, crystalline films are more effective barrier layers than amorphous films

  13. High temperature impedance spectroscopy of barium stannate ...

    Indian Academy of Sciences (India)

    (M = Ba, Sr, Ca and Pb). ... Barium stannate (BaSnO3) is a cubic pervoskite oxide com- .... were gold-sputtered and scanned in different regions using .... de ions. Water insertion into the oxide structure can be re- presented as the process of ...

  14. Improved thermal stability and wettability behavior of thermoplastic polyurethane / barium metaborate composites

    International Nuclear Information System (INIS)

    Baştürka, Emre; Madakbaş, Seyfullah; Kahraman, Memet Vezir

    2016-01-01

    In this paper, it was targeted to the enhance thermal stability and wettability behavior of thermoplastic polyurethane (TPU) by adding barium metaborate. TPU-Barium metaborate composites were prepared by adding various proportions of barium metaborate to TPU. The chemical structures of the composites were characterised by fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) analysis. All prepared composites have extremely high Tg and thermal stability as determined from DSC and TGA analysis. All composite materials have the Tg ranging from 15 to 35 °C. The surface morphologies of the composites were investigated by a scanning electron microscopy. Mechanical properties of the samples were characterized with stress-strain test. Hydrophobicity of the samples was determined by the contact angle measurements. The obtained results proved that thermal, hydrophobic and mechanical properties were improved. (author)

  15. Improved thermal stability and wettability behavior of thermoplastic polyurethane / barium metaborate composites

    Energy Technology Data Exchange (ETDEWEB)

    Baştürka, Emre; Madakbaş, Seyfullah; Kahraman, Memet Vezir, E-mail: smadakbas@marmara.edu.tr [Department of Chemistry, Marmara University, Istanbul (Turkey)

    2016-03-15

    In this paper, it was targeted to the enhance thermal stability and wettability behavior of thermoplastic polyurethane (TPU) by adding barium metaborate. TPU-Barium metaborate composites were prepared by adding various proportions of barium metaborate to TPU. The chemical structures of the composites were characterised by fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) analysis. All prepared composites have extremely high Tg and thermal stability as determined from DSC and TGA analysis. All composite materials have the Tg ranging from 15 to 35 °C. The surface morphologies of the composites were investigated by a scanning electron microscopy. Mechanical properties of the samples were characterized with stress-strain test. Hydrophobicity of the samples was determined by the contact angle measurements. The obtained results proved that thermal, hydrophobic and mechanical properties were improved. (author)

  16. Deposition barium titanate (BaTiO3) doped lanthanum with chemical solution deposition

    International Nuclear Information System (INIS)

    Iriani, Y.; Nurhadi, N.; Jamaludin, A.

    2016-01-01

    Deposition of Barium Titanate (BaTiO 3 ) thin films used Chemical Solution Deposition (CSD) method and prepared with spin coater. BaTiO 3 is doped with lanthanum, 1%, 2%, and 3%. The thermal process use annealing temperature 900°C and holding time for 3 hours. The result of characterization with x-ray diffraction (XRD) equipment show that the addition of La 3+ doped on Barium Titanate caused the change of angle diffraction.The result of refine with GSAS software shows that lanthanum have been included in the structure of BaTiO 3 . Increasing mol dopant La 3+ cause lattice parameter and crystal volume become smaller. Characterization result using Scanning Electron Microscopy (SEM) equipment show that grain size (grain size) become smaller with increasing mole dopant (x) La 3+ . The result of characterization using Sawyer Tower methods show that all the samples (Barium Titanante and Barium Titanate doped lanthanum) are ferroelectric material. Increasing of mole dopant La 3+ cause smaller coercive field and remanent polarization increases. (paper)

  17. Indentation plasticity of barium titanate single crystals: Dislocation influence on ferroelectric domain walls

    International Nuclear Information System (INIS)

    Liu, D.; Chelf, M.; White, K.W.

    2006-01-01

    The plastic behaviors of barium titanate (001) and (110) single crystals are studied with atomic force microscopy and piezoresponse force microscopy (PFM) following nanoindendation damage. Plastic deformation mechanisms of ferroelectric barium titanate single crystals are discussed with a focus on the interaction between PFM response and dislocation activities. Nanoindentation tests indicate that the theoretical strength is approached prior to the first pop-in event, consistent with the creation of dislocation nucleation sites required for the onset of plasticity. Surface topographic and piezoelectric analyses indicate that pile-ups around indents result from dislocation activities on the primary slip system, {110} pc pc . The more complex indentation-induced domain patterns observed on (110) barium titanate are also discussed

  18. Features of time–intensity curve parameters of colorectal adenocarcinomas evaluated by double-contrast enhanced ultrasonography: Initial observation

    International Nuclear Information System (INIS)

    Zhuang Hua; Yang Zhigang; Wang Ziqiang; Wang Xiaodong; Chen Huijiao; Zhang Yuanchuan; Luo Yan

    2012-01-01

    Purpose: This study is to investigate the value of double contrast-enhanced ultrasonography (DCEU) in assessing microcirculation of colorectal adenocarcinomas and to describe the perfusion features of the tumours. Material and methods: DCEUS was performed in 42 patients with adenocarcinoma. The time–intensity curve parameters (arrival time (AT), time-to-peak (TTP), peak intensity (PI) and area under the curve (AUC)) within the tumours were extracted. The parameters were compared among the tumours with different CEUS features and stages. Results: The mean values of AT, TTP, PI and AUC of the colorectal adenocarcinomas were 13.68 ± 13.36 s, 32.61 ± 19.56 s, 19.82 ± 16.54 dB and 271.10 ± 159.19 dB s, respectively. In the adenocarcinomas with necrosis, the mean values of AUC was significantly lower than that of the adenocarcinomas without (231.10 ± 219.27 dB s, 278.10 ± 123.20 dB s, p = 0.004). In the adenocarcinomas with necrosis, the AUC and PI of the non-necrotic part were significantly higher than that of the necrotic part (p = 0.007, 0.0025, respectively). AUC increased progressively in the subgroups of T2, T3 and T4 and the difference of AUC between T2 and T4 subgroup was significant (p = 0.008). Conclusions: Double contrast-enhanced ultrasonography is a valuable technique for quantifying tumour vascularity of colorectal adenocarcinomas. AUC was significantly different in the subgroups of different T stage. AUC and PI could reflect the different perfusion status of tumours with or without necrosis.

  19. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    Science.gov (United States)

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  20. Fabrication and electrical characterization of 15% yttrium-doped barium zirconate-nitrate freeze drying method combined with vacuum heating

    International Nuclear Information System (INIS)

    Imashuku, Susumu; Uda, Tetsuya; Nose, Yoshitaro; Awakura, Yasuhiro

    2011-01-01

    Research highlights: → Very fine 15% yttrium-doped barium zirconate powder of particle size about 30 nm was obtained by synthesizing at 500 deg. C in vacuum from powder mixed by the nitrate freeze-drying method. → Large and homogeneous grains of 15% yttrium-doped barium zirconate were easily obtained using the synthesized powder. → Grain boundary resistance was not inversely proportional to the grain size as theoretically expected. → Specific grain boundary conductivity varies with samples because impurities and/or evaporation loss of barium oxide might affect the grain-boundary resistance in 15% yttrium-doped barium zirconate. - Abstract: We applied a nitrate freeze-drying method to obtain a fine synthesized powder of 15% yttrium-doped barium zirconate. Fine 15% yttrium-doped barium zirconate powder of particle size about 30 nm was obtained by synthesizing at 500 deg. C in vacuum from a powder mixed by the nitrate freeze-drying method. However, we could not obtain such fine powder by synthesizing in air. Using the powder synthesized in vacuum, large and homogeneous grains of 15% yttrium-doped barium zirconate were easily obtained after sintering. Then, the bulk and grain boundary resistance were evaluated by AC 2-terminal measurement of sample in the form of bar and pellet and DC 4-terminal measurement of bar-shape sample. The grain boundary resistance was not inversely proportional to the grain size as theoretically expected. We concluded that specific grain boundary conductivity varies with samples. Some impurities, evaporation loss of barium oxide and/or other unexpected reasons might affect the grain boundary resistance in 15% yttrium-doped barium zirconate.

  1. Barium isotopes in Allende meteorite - Evidence against an extinct superheavy element

    Science.gov (United States)

    Lewis, R. S.; Anders, E.; Shimamura, T.; Lugmair, G. W.

    1983-01-01

    Carbon and chromite fractions from the Allende meteorite that contain isotopically anomalous xenon-131 to xenon-136 (carbonaceous chondrite fission or CCF xenon) at up to 5 x 10 to the 11th atoms per gram show no detectable isotopic anomalies in barium-130 to barium-138. This rules out the possibility that the CCF xenon was formed by in situ fission of an extinct superheavy element. Apparently the CCF xenon and its carbonaceous carrier are relics from stellar nucleosynthesis.

  2. 75 FR 19657 - Barium Chloride From China

    Science.gov (United States)

    2010-04-15

    ... China AGENCY: United States International Trade Commission. ACTION: Notice of Commission determination... China. SUMMARY: The Commission hereby gives notice that it will proceed with a full review pursuant to... antidumping duty order on barium chloride from China would be likely to lead to continuation or recurrence of...

  3. Esophageal intramural pseudodiverticulosis characterized by barium esophagography: a case report

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-05-21

    Abstract Introduction Esophageal intramural pseudodiverticulosis is a rare condition characterized by the dilatation of the submucosal glands. Case presentation We present a case of esophageal intramural pseudodiverticulosis in a 72-year-old Caucasian man who presented with dysphagia and with a background history of alcohol abuse. An upper gastrointestinal endoscopy of our patient showed an esophageal stricture with abnormal mucosal appearances, but no malignant cells were seen at biopsy. Appearances on a barium esophagram were pathognomonic for esophageal intramural pseudodiverticulosis. Conclusion We demonstrate the enduring usefulness of barium esophagography in the characterization of abnormal mucosal appearances at endoscopy.

  4. Bronchography in dogs. Comparative study with two barium sulphate solutions; Broncografía en perros. Estudio comparativo con dos concentraciones de sulfato de bario

    Energy Technology Data Exchange (ETDEWEB)

    Thibaut, J.; Gallardo, P.; Vargas, L.; Deppe, R.; Born, R. [Universidad Austral de Chile, Valdivia (Chile)

    1998-07-01

    Two solutions of barium sulphate, 60 and 30% w/v, were compared with the ''overflow'' Bronchographic method. Two groups of eight healthy adult does of both sexes, weighing 7 to 18 kg were used for the study. The dogs were anaesthetised with thiopentone sodium 2% (20 mg/kg iv). After intubation, each dog received contrast medium by a catheter connected to a syringe, in a 9 mi dose. Two series of two x-rays plates were taken in left lateral recumbent, 3 and 6 min after administering the contrast medium and in ventrodorsal projection, 30 sec. later. The x-ray plates obtained were analysed and compared intra and inter group considering the advance speed of the contrast medium, the radiographic density and outlines. Adverse reactions were controlled.

  5. Evidence against barium in the mushroom Trogia venenata as a cause of sudden unexpected deaths in Yunnan, China.

    Science.gov (United States)

    Zhang, Ying; Li, Yanchun; Wu, Gang; Feng, Bang; Yoell, Shanze; Yu, Zefen; Zhang, Keqin; Xu, Jianping

    2012-12-01

    This study examined barium concentrations in the mushroom Trogia venenata, the leading culprit for sudden unexpected deaths in Yunnan, southwest China. We found that barium concentrations in T. venenata from Yunnan were low and comparable to other foods, inconsistent with barium concentrations in this mushroom as a significant contributor to these deaths.

  6. Barium borate nanorod decorated reduced graphene oxide for optical power limiting applications

    Science.gov (United States)

    Muruganandi, G.; Saravanan, M.; Vinitha, G.; Jessie Raj, M. B.; Sabari Girisun, T. C.

    2018-01-01

    By simple hydrothermal method, nanorods of barium boate were successfully loaded on reduced graphene oxide sheets. Powder XRD confirms the incorporation of barium borate (2θ = 29°, (202)) along with the transition of graphene oxide (2θ = 12°, (001)) into reduced graphene oxide (2θ = 25°, (002)). In the FTIR spectra, presence of characteristic absorption peaks of rGO (1572 and 2928 cm-1) and barium borate (510, 760 and 856 cm-1) further evidences the formation of BBO:rGO nanocomposite. FESEM images potray the existence of graphene sheets as thin layers and growth of barium borate as nanorods on the sheets of reduced graphene oxide. Ground state absorption studies reveal the hypsochromic shift in the absorption maxima of the graphene layers due to reduction of graphene oxide and hypochromic shift in the absorbance intensity due to the inclusion of highly transparent barium bortae. The photoluminescence of BBO:rGO shows maximum emission in the UV region arising from the direct transitions involving the valence band and conduction band in the band gap region. Z-scan technique using CW diode pumped Nd:YAG laser (532 nm, 50 mW) exposes that both nanocomposite and individual counterpart possess saturable absorption and self-defocusing behavior. Third-order nonlinear optical coefficients of BBO:rGO nanocomposite is found to be higher than bare graphene oxide. In particular the nonlinear refractive index of nanocomposite is almost four times higher than GO which resulted in superior optical power limiting action. Strong nonlinear refraction (self-defocusing) and lower onset limiting thershold makes the BBO:rGO nanocomposite preferable candidate for laser safety devices.

  7. A surface-chemistry study of barium ferrite nanoplates with DBSa-modified surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lisjak, Darja, E-mail: darja.lisjak@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Ovtar, Simona; Kovač, Janez [Jožef Stefan Institute, Ljubljana (Slovenia); Gregoratti, Luca; Aleman, Belen; Amati, Matteo [Elettra – Sincrotrone Trieste S.C.p.A. di interesse nazionale, Trieste (Italy); Fanetti, Mattia [University of Nova Gorica, Nova Gorica (Slovenia); Istituto Officina dei Materiali CNR, Area Science Park, Trieste (Italy); Makovec, Darko [Jožef Stefan Institute, Ljubljana (Slovenia)

    2014-06-01

    Barium ferrite (BaFe{sub 12}O{sub 19}) is a ferrimagnetic oxide with a high magnetocrystalline anisotropy that can be exploited in magnetically aligned ceramics or films for self-biased magnetic applications. Magnetic alignment of the films can be achieved by the directed assembly of barium ferrite nanoplates. In this investigation the nanoplates were synthesized hydrothermally and suspended in 1-butanol using dodecylbenzene sulphonic acid (DBSa) as a surfactant. They were then deposited in an electric or magnetic field on flat substrates and exhibited a significant preferential alignment in the plane of the substrate, allowing a differentiation between the analysis of their basal and side planes using scanning photoelectron microscopy with a lateral resolution down to 100 nm. The surface chemistry of the nanoplates was additionally studied with X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry. For a comparison, bare barium ferrite nanoplates were also analyzed after decomposing the DBSa at 460 °C. The deviation of the surface chemistry from the stoichiometric composition was observed and the adsorption of the DBSa molecules on the nanoplates was confirmed with all three methods. Different types of bonding (physi- or chemisorption) were possible and considered with respect to the assembly of the barium ferrite nanoplates into anisotropic magnetic films.

  8. Individual-specific transgenerational marking of fish populations based on a barium dual-isotope procedure.

    Science.gov (United States)

    Huelga-Suarez, Gonzalo; Moldovan, Mariella; Garcia-Valiente, America; Garcia-Vazquez, Eva; Alonso, J Ignacio Garcia

    2012-01-03

    The present study focuses on the development and evaluation of an individual-specific transgenerational marking procedure using two enriched barium isotopes, (135)Ba and (137)Ba, mixed at a given and selectable molar ratio. The method is based on the deconvolution of the isotope patterns found in the sample into four molar contribution factors: natural xenon (Xe nat), natural barium (Ba nat), Ba135, and Ba137. The ratio of molar contributions between Ba137 and Ba135 is constant and independent of the contribution of natural barium in the sample. This procedure was tested in brown trout ( Salmo trutta ) kept in captivity. Trout were injected with three different Ba137/Ba135 isotopic signatures ca. 7 months and 7 days before spawning to compare the efficiency of the marking procedure at long and short term, respectively. The barium isotopic profiles were measured in the offspring by means of inductively coupled plasma mass spectrometry. Each of the three different isotopic signatures was unequivocally identified in the offspring in both whole eggs and larvae. For 9 month old offspring, the characteristic barium isotope signatures could also be detected in the otoliths even in the presence of a high and variable amount of barium of natural isotope abundance. In conclusion, it can be stated that the proposed dual-isotope marking is inheritable and can be detected after both long-term and short-term marking. Furthermore, the dual-isotope marking can be made individual-specific, so that it allows identification of offspring from a single individual or a group of individuals within a given fish group. © 2011 American Chemical Society

  9. Barium ferrite nanoparticles prepared by self-propagating low ...

    Indian Academy of Sciences (India)

    Administrator

    Kubo et al 1982; Lucchini et al 1983), hydrothermal. (Barb et al 1986), microemulsion ... combustion route employing metal oxalate precursors. In search of a suitable ... heptahydrate/barium nitrate and oxalic acid were dis- solved in minimum ...

  10. Study of decomposition kinetics of volatile β-diketonates of yttrium, barium and copper in flow reactor

    International Nuclear Information System (INIS)

    Devyatykh, G.G.; Gavrishchuk, E.M.; Gibin, A.M.; Dadanov, A.Yu.; Dzyubenko, N.G.; Kaul', A.R.; Nichiporuk, R.V.; Snezhko, N.T.; Ul'yanov, A.A.

    1990-01-01

    Heterogeneous oxidative decomposition of adduct of yttrium acetylacetonate with o-phenanthroline, copper acetylacetonate and barium dipivaloylmethanate in a flow-type reactor was carried out. The basic kinetic characteristics of chemical precipitation processes of films of yttrium, copper and barium oxides, which are components of high-temperature superconductors, were obtained. The values of activation energy of precipitation process of yttrium, copper and barium oxides constituted 76±10, 108±15, 81±12 (t 600 deg C) respectively

  11. A Comparative Study on Magnetostructural Properties of Barium Hexaferrite Powders Prepared by Polyethylene Glycol

    Directory of Open Access Journals (Sweden)

    Zehra Durmus

    2014-01-01

    Full Text Available Nanocrystalline particles of barium hexaferrite were synthesized by a sol-gel combustion route using nitrate-citrate gels prepared from metal nitrates and citric acid solutions with Fe/Ba molar ratio 12. The present paper aims to study the effect of addition of polyethylene glycol (PEG solutions with different molecular weights (MW: 400, 2000, and 10.000 g/mol on magnetostructural properties of barium hexaferrite. The formation of the barium hexaferrite was inspected using X-ray diffraction (XRD analysis, Fourier transform infrared (FT-IR analysis, thermogravimetric (TGA analysis, scanning electron microscopy (SEM analysis and vibrating sample magnetometer (VSM analysis for magnetic measurements.

  12. Barium promotes anchorage-independent growth and invasion of human HaCaT keratinocytes via activation of c-SRC kinase.

    Science.gov (United States)

    Thang, Nguyen Dinh; Yajima, Ichiro; Kumasaka, Mayuko Y; Ohnuma, Shoko; Yanagishita, Takeshi; Hayashi, Rumiko; Shekhar, Hossain U; Watanabe, Daisuke; Kato, Masashi

    2011-01-01

    Explosive increases in skin cancers have been reported in more than 36 million patients with arsenicosis caused by drinking arsenic-polluted well water. This study and previous studies showed high levels of barium as well as arsenic in the well water. However, there have been no reports showing a correlation between barium and cancer. In this study, we examined whether barium (BaCl(2)) may independently have cancer-related effects on human precancerous keratinocytes (HaCaT). Barium (5-50 µM) biologically promoted anchorage-independent growth and invasion of HaCaT cells in vitro. Barium (5 µM) biochemically enhanced activities of c-SRC, FAK, ERK and MT1-MMP molecules, which regulate anchorage-independent growth and/or invasion. A SRC kinase specific inhibitor, protein phosphatase 2 (PP2), blocked barium-mediated promotion of anchorage-independent growth and invasion with decreased c-SRC kinase activity. Barium (2.5-5 µM) also promoted anchorage-independent growth and invasion of fibroblasts (NIH3T3) and immortalized nontumorigenic melanocytes (melan-a), but not transformed cutaneous squamous cell carcinoma (HSC5 and A431) and malignant melanoma (Mel-ret) cells, with activation of c-SRC kinase. Taken together, our biological and biochemical findings newly suggest that the levels of barium shown in drinking well water independently has the cancer-promoting effects on precancerous keratinocytes, fibroblast and melanocytes in vitro.

  13. The role of the Ganges-Brahmaputra mixing zone in supplying barium and 226Ra to the Bay of Bengal

    International Nuclear Information System (INIS)

    Carroll, J.; Falkner, K.K.; Brown, E.T.; Moore, W.S.

    1993-01-01

    The Ganges-Brahmaputra river system is ranked fourth among world rivers as a source of freshwater to the oceans and is believed to supply more sediment to the ocean than any other; 1.5 x 10 12 kg/yr (Milliman and Meade, 1983). Barium and 226 Ra are typically enriched in waters where sediment-laden rivers enter the ocean. As such, the Ganges-Brahmaputra is likely to produce globally significant barium and 226 Ra fluxes to the ocean. Water samples for barium and 226 Ra were collected within four major channels of the Ganges-Brahmaputra mixing zone during a period of low sediment and freshwater discharge. The data suggest that in addition to suspended sediments supplied directly from rivers, river sediments deposited during high discharge in mangroves and on islands are desorbing barium and 226 Ra to seawater. The release of barium and 226 Ra from these sediment deposits is out-of-phase with the direct supply of sediments from the rivers. Estimates of the annual fluxes of barium and 226 Ra from the Ganges-Brahmaputra mixing zone were also derived. The fluxes of barium and 226 Ra are 5.3 x 10 8 mol barium/yr and 9.5 x 10 14 dpm radium/yr. The first silicate and phosphate mixing profiles for this system are reported. 29 refs., 6 figs., 3 tabs

  14. Indentation plasticity of barium titanate single crystals: Dislocation influence on ferroelectric domain walls

    Energy Technology Data Exchange (ETDEWEB)

    Liu, D. [Department of Mechanical Engineering, University of Houston, 4800 Calhoun Road, Houston, TX 77204 (United States)]. E-mail: duo.liu@mail.uh.edu; Chelf, M. [Department of Mechanical Engineering, University of Houston, 4800 Calhoun Road, Houston, TX 77204 (United States); White, K.W. [Department of Mechanical Engineering, University of Houston, 4800 Calhoun Road, Houston, TX 77204 (United States)

    2006-10-15

    The plastic behaviors of barium titanate (001) and (110) single crystals are studied with atomic force microscopy and piezoresponse force microscopy (PFM) following nanoindendation damage. Plastic deformation mechanisms of ferroelectric barium titanate single crystals are discussed with a focus on the interaction between PFM response and dislocation activities. Nanoindentation tests indicate that the theoretical strength is approached prior to the first pop-in event, consistent with the creation of dislocation nucleation sites required for the onset of plasticity. Surface topographic and piezoelectric analyses indicate that pile-ups around indents result from dislocation activities on the primary slip system, {l_brace}110{r_brace}{sub pc}<11-bar 0>{sub pc}. The more complex indentation-induced domain patterns observed on (110) barium titanate are also discussed.

  15. MR-cholangiography with a double contrast technique

    International Nuclear Information System (INIS)

    Hemmingsson, A.; Carlsten, J.; Ericsson, A.; Holtz, E.; Klaveness, J.; Loennemark, M.; Nyman, R.

    1989-01-01

    The combination of superparamagnetic particles (SPP) as a ''negative'' contrast agent for the liver parenchyma and Cr-HIDA as a ''positive'' one for the bile ducts was tested in dogs. The maximum effect of SPP was present about 30 minutes after injection with a reduction of the image intensity of the liver close to the background noise level at the highest dosages. This effect lasted for about 4 to 5 hours and it had disappeared after 24 hours. Before any contrast administration or after Cr-HIDA the bile ducts were not discernible, but a high signal in the gallbladder was present 15 to 30 minutes after injection of Cr-HIDA. After SPP the wider bile ducts were discernible because of the lowering of the signal intensity in the liver. When SPP were followed by Cr-HIDA, the bile had a higher signal intensity, and even tiny bile ducts were visible. After cholecystokinin visualization of the choledochus duct was achieved as well as contrast filling of the duodenum. The blood, urine and liver function tests were found normal during the experiments. The combination of superparamagnetic particles and Cr-HIDA seems to be a promising method for MR-cholangiography. An evaluation of the anatomic structures of the liver should be possible with this method in different pathologies. (orig.)

  16. Clearance of barium from the oesophagus with diet cola and metoclopramide: A one stop approach to patients with dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, J.; Farrow, R.; Hussaini, S.H.; Dalton, H.R

    2001-01-01

    AIM: To establish a 'one-stop' dysphagia service in which a consultation, barium swallow and endoscopy can all be performed in the same hospital visit. MATERIALS AND METHODS: In order to allow both barium swallow examination and endoscopy to be performed on the same day, a novel technique for clearing barium from the upper gastrointestinal tract was established. Following the barium swallow examination, patients were given diet cola and metoclopramide syrup. If appropriate, an upper gastrointestinal endoscopy was then performed shortly afterwards. The service was piloted for 6 months in which time 25 patients were investigated in this way. RESULTS: All patients were seen within 2 weeks of referral. The mean time between barium swallow and endoscopy was 3 h 38 min (range, 1 h 50 min to 5 h 20 min). In all 24 patients in whom an endoscopy was performed, barium had been satisfactorily cleared from the oesophagus and stomach. CONCLUSION: This technique allows both barium swallow and upper gastrointestinal endoscopy to be performed on the same day, providing a rapid, safe and accurate diagnosis with minimum patient inconvenience. Mitchell, J. (2001)

  17. Clearance of barium from the oesophagus with diet cola and metoclopramide: A one stop approach to patients with dysphagia

    International Nuclear Information System (INIS)

    Mitchell, J.; Farrow, R.; Hussaini, S.H.; Dalton, H.R.

    2001-01-01

    AIM: To establish a 'one-stop' dysphagia service in which a consultation, barium swallow and endoscopy can all be performed in the same hospital visit. MATERIALS AND METHODS: In order to allow both barium swallow examination and endoscopy to be performed on the same day, a novel technique for clearing barium from the upper gastrointestinal tract was established. Following the barium swallow examination, patients were given diet cola and metoclopramide syrup. If appropriate, an upper gastrointestinal endoscopy was then performed shortly afterwards. The service was piloted for 6 months in which time 25 patients were investigated in this way. RESULTS: All patients were seen within 2 weeks of referral. The mean time between barium swallow and endoscopy was 3 h 38 min (range, 1 h 50 min to 5 h 20 min). In all 24 patients in whom an endoscopy was performed, barium had been satisfactorily cleared from the oesophagus and stomach. CONCLUSION: This technique allows both barium swallow and upper gastrointestinal endoscopy to be performed on the same day, providing a rapid, safe and accurate diagnosis with minimum patient inconvenience. Mitchell, J. (2001)

  18. Reducing conditions on barium absorption in rice plants cultured in BaSO4-enriched soil doi: 10.4025/actasciagron.v36i1.17539

    Directory of Open Access Journals (Sweden)

    Marcio Osvaldo Lima Magalhães

    2014-01-01

    Full Text Available To evaluate the possible solubilization of barium sulfate in soils under reducing conditions and its effects on barium bioavailability, an Oryza sativa pot trial was established. Increasing barium doses and two redox potential conditions were evaluated. The geochemical fractionation data demonstrated that reducing conditions led to an increase in the levels of more labile forms of barium and a reduction in more stable forms. Furthermore, higher doses of barium were found to have a negative impact on grain production. The highest levels of barium accumulation in the leaves, roots, and grains were observed with the highest barium dose under reducing conditions. These results demonstrate that reducing conditions increased barium bioavailability and absorption by rice plants.

  19. Feasibility and usefulness of using swallow contrast-enhanced ultrasound to diagnose Zenker's diverticulum: preliminary results.

    Science.gov (United States)

    Cui, Xin-Wu; Ignee, Andre; Baum, Ulrich; Dietrich, Christoph F

    2015-04-01

    Zenker's diverticulum (ZD) may be misdiagnosed on conventional ultrasound as a thyroid nodule or other lesion. A barium esophagram is usually used to confirm the diagnosis; however, this procedure exposes the patient to radiation. The aim of this study was to evaluate the feasibility of using swallow contrast-enhanced ultrasound (swallow-CEUS) to diagnose ZD. Ten consecutive patients with ZD (7 men and 3 women, aged 67 ± 11 y) were included in the study. In 4 patients, ZD was incidentally found on head and neck ultrasound, and in 6 patients, ZD was suspected because of dysphagia. All lesions could be detected on conventional ultrasound before swallow-CEUS. Ten healthy volunteers (8 men and 2 women, aged 60 ± 12 y) were chosen as a control group. Written informed consent was obtained. With the patient in the sitting or upright position, conventional ultrasound was performed first to image the lesion, then the patient was asked to swallow ultrasound contrast agent (UCA) (2-4 drops of SonoVue diluted with about 200 mL of tap water). Transity of the contrast agent in the esophagus was imaged with CEUS. Retention of the UCA in the diverticulum was monitored for at least 3 min. All patients underwent a barium esophagram as the gold standard. Swallow-CEUS revealed that in all patients (100%), the UCA was transported from the pharynx to the esophagus while the patient swallowed. ZD appeared as a pouch-shaped structure at the posterior pharyngo-esophageal junction that retained UCA longer than 3 min. The barium esophagram confirmed the diagnosis of ZD in all patients. For the 10 volunteers, no abnormal structure (retaining UCA) was detected during or after swallowing of UCA. With the advantages of no radiation and bedside availability, swallow-CEUS may become a method of choice in confirmation of the diagnosis of ZD, especially when ZD is suspected on conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier

  20. 75 FR 33824 - Barium Chloride From China

    Science.gov (United States)

    2010-06-15

    ... China Determination On the basis of the record\\1\\ developed in the subject five-year review, the United... China would be likely to lead to continuation or recurrence of material injury to an industry in the... contained in USITC Publication 4157 (June 2010), entitled Barium Chloride from China: Investigation No. 731...