WorldWideScience

Sample records for doses ocupacionais devido

  1. Occupational doses due to photoneutrons in medical linear accelerators rooms; Doses ocupacionais devido a neutrons em salas de aceleradores lineares de uso medico

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Alessandro Facure Neves de Salles

    2006-04-15

    Medical linear accelerators, with maximum photon energies above 10 MeV, are becoming of common use in Brazil. Although desirable in the therapeutic point of view, the increase in photon energies causes the generation of undesired neutrons, which are produced through nuclear reactions between photons and the high Z target nuclei of the materials that constitute the accelerator head. In this work, MCNP simulation was undertaken to examine the neutron equivalent doses around the accelerators head and at the entrance of medical linear accelerators treatment rooms, some of them licensed in Brazil by the National Regulatory Agency (CNEN). The simulated neutron dose equivalents varied between 2 e 26 {mu} Sv/Gy{sub RX}, and the results were compared with calculations performed with the use of some semi-empirical equations found in literature. It was found that the semi-empirical equations underestimate the simulated neutron doses in the majority of the cases, if compared to the simulated values, suggesting that these equations must be revised, due to the increasing number of high energy machines in the country. (author)

  2. Rabdomiólise devido ao uso de estatina em altas doses: relato de caso

    OpenAIRE

    Gama, Mirnaluci P. Ribeiro; Pellegrinello, Silviane; Alonso, Sheyla Santos Quelle; Coelho, Juliana Filus; Martins, Caroline F. Luz; Biagini, Gleyne Lopes Kujew

    2005-01-01

    A rabdomiólise tem sido motivo de publicação na literatura médica há mais de 50 anos. Nas últimas décadas, com o advento das estatinas, usadas na prevenção primária e secundária da doença cardiovascular, este assunto volta como importante complicação, muitas vezes fatal, do uso desta classe de drogas. A rabdomiólise associada ao uso das estatinas ocorre principalmente devido a associações medicamentosas. A seguir, descreveremos um caso de uma paciente em uso de altas doses de Sinvastatina, de...

  3. Occupational doses in neuroendocrine tumors by using {sup 177}Lu DOTATATE; Doses ocupacionais em tratamento de tumores neuroendocrinos utilizando {sup 17'}7Lu DOTATATE

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Gustavo Coelho Alves; Sa, Lidia Vasconcellos de, E-mail: gustavo@ird.gov.b, E-mail: lidia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper investigated the treatment of neuroendocrine tumors (abdominal tumors) using of {sup 177}Lu DOTATATE radiopharmaceutical which is a type of treatment presently used in the experimental form in Brazil and, therefore, not contemplated in norms or specific use. This research studied the occupational doses of this treatment and suggested guidelines or rules of procedures viewing the radiological protection of workers involved and the public. The treatment were followed up by using two types of radiation detection, one a scintillator and a Geiger-Muller, and the measurements were performed in a public hospital at Rio de Janeiro and the other in a private hospital at Sao Paulo. It was observed that the equivalent occupational doses can variate from 160 {mu}Sv to 450 {mu}Sv, in function of operator, of stage of manipulation, and of the administration method, which can be through the use of infusion pump or manual injection. The use of infusion pump is highly recommended and the hospitalization of the patient until the dose rate measured at 1 m does not surpass 20 {mu}Sv/h

  4. Absorbed dose due to radioiodine therapy by organs of patients with hyperthyroidism; Dose absorvida em orgaos de pacientes com hipertiroidismo devido a radioiodoterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, F.F.; Khoury, H.J.; Bertelli Neto, L. [Pernambuco Univ., Recife, PE (Brazil); Laboratorios CERPE, Recife, PE (Brazil); Bertelli Neto, L. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil)

    1999-07-01

    The dose absorbed by organs of patients with hyperthyroidism treated with {sup 131} I was estimated by using the MIRDOSE computer program and data from ICRP-53. The calculation were performed using effective half-life and uptake average values, which were determined for 17 patients treated with 370 MBq and 555MBq of {sup 131} I. The results shown that the dose in the thyroid, for a 370 MBq administrated activity, was of 99 Gy and 49.5 Gy for 60 g and 80 g thyroid respectively. The average dose estimated in other organs were relatively low, presenting values lower than 0.1 Gy in the kidneys, bone marrow and ovaries and 0.19 Gy in the stomach.

  5. Dose calculation for {sup 40}K ingestion in samples of beans using spectrometry and MCNP; Calculo de dose devido a ingestao de {sup 40}K em amostras de feijao utilizando espectrometria e MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Garcez, R.W.D.; Lopes, J.M.; Silva, A.X., E-mail: marqueslopez@yahoo.com.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/PEN/UFRJ), Rio de Janeiro, RJ (Brazil). Centro de Tecnologia; Domingues, A.M. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Instituto de Fisica; Lima, M.A.F. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Instituto de Biologia

    2014-07-01

    A method based on gamma spectroscopy and on the use of voxel phantoms to calculate dose due to ingestion of {sup 40}K contained in bean samples are presented in this work. To quantify the activity of radionuclide, HPGe detector was used and the data entered in the input file of MCNP code. The highest value of equivalent dose was 7.83 μSv.y{sup -1} in the stomach for white beans, whose activity 452.4 Bq.Kg{sup -1} was the highest of the five analyzed. The tool proved to be appropriate when you want to calculate the dose in organs due to ingestion of food. (author)

  6. Dose evaluation due to the effluent liberation by medical installations at city of Rio de Janeiro, Brazil; Avaliacao de doses devido a liberacao de efluentes por instalacoes medicas na cidade do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Jane; Rochedo, Elaine R.R., E-mail: jshu@cnen.gov.b, E-mail: erochedo@cnen.gov.b [Comissao Nacional de Energia Nuclear (CODIN/CNEN), Rio de Janeiro, RJ (Brazil). Coordenacao de Instalacoes Nucleares; Heilbron, Paulo F.L., E-mail: paulo@cnen.gov.b [Comissao Nacional de Energia Nuclear (COREJ/CNEN), Rio de Janeiro, RJ (Brazil). Coordenacao de Rejeitos; Crispim, Verginia R., E-mail: verginia@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2011-10-26

    This paper, the city of Rio de Janeiro was taken as a case study. It was processed deterministic and probabilistic simulations vor evaluation of the dose in two exposure sceneries, one of them referring to public members exposure and the other relative to exposure of sewage sanitary treatment plant workers. The results showed that at present the doses for inhabitants of the city and operators of treatment station are lower to dose limit established for the public, the approach presently in use in Brazil is not sufficient to accomplish whit international requirements and the regulation should be revised to be adopted specific values for each radionuclide

  7. Absorbed doses by the thyroid follicles due to the short half-lives isotope; Dose absorvida pelos foliculos tireoideanos devido aos isotopos de iodo de meia-vida curta

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia; Amaral, Ademir; Colas-Linhart, Nicole; Hindie, Elif; Oliveira, Jairo R. de; Oliveira, Pedro A.R. de [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR); Universite Paris 7, Paris Cedex 18 (France). Faculte de Medecine Xavier Bichat. Lab. de Chimie et Biophysique des Traceurs; Paris Cedex 12 (France). Hopital Saint-Antoine. Service de Medecine Nucleaire; Universidade Federal de Pernambuco UFPE, Recife, PE (Brazil). Dept. de Fisica e Matematica; E-mails: lpbcampos@uol.com.br; amaral@ufpe.br

    2005-11-15

    The aim of this work is to evaluate the contributions of internally deposited short-lived iodines to the dose absorbed by thyroid's follicle, in the case of nuclear accidents . Dose calculation was carried out, at follicular level, for {sup 131} I and short-lived iodines ({sup 132}I, {sup 133}I, {sup 134}I and {sup 135}I), using the code MCNP4C. The thyroid's follicles were modeled as spheres, with different diameters (between 40 to 240 {mu}m), having the same density as for soft tissue ({rho} = 1.04 g.cm{sup -3}). The results showed that the contribution of short-lived iodines for total dose is about 72%. The results reported in this work pointed out that, in case of nuclear accidents, the contributions of the short-lived iodines to the total dose absorbed by thyroid, at follicular level, cannot be neglected in a prospective evaluation of risks associated to internal contamination by radioactive iodine.(author)

  8. Reconstructive dosimetry and radiation doses evaluation of members of the public due to radiological accident in industrial radiography; Dosimetria reconstrutiva e avaliacao de dose de individuos do publico devido a acidente radiologico em radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Camila Moreira Araujo de

    2016-07-01

    Radiological accidents have occurred mainly in the practices recognized as high risk radiological and classified by the IAEA as Categories 1 and 2, and highlighted the radiotherapy, industrial irradiators and industrial radiography. In Brazil, since there were five major cases in industrial radiography, which involved 7 radiation workers and 19 members of the public, causing localized radiation lesions on the hands and fingers. One of these accidents will be the focus of this work. In this accident, a {sup 192}Ir radioactive source was exposed for more than 8 hours in the workplace inside a company, exposing radiation workers, individuals of the public and people from the surrounding facilities, including children of a school. The radioactive source was also handled by a security worker causing severe radiation injuries in the hand and fingers. In this paper, the most relevant and used techniques of reconstructive dosimetry internationally are presented. To estimate the radiation doses received by exposed individuals in various scenarios of radiological accident in focus, the following computer codes were used: Visual Monte Carlo Dose Calculation (VMC), Virtual Environment for Radiological and Nuclear Accidents Simulation (AVSAR) and RADPRO Calculator. Through these codes some radiation doses were estimated, such as, 33.90 Gy in security worker's finger, 4.47 mSv in children in the school and 55 to 160 mSv for workers in the company during the whole day work. It is intended that this work will contribute to the improvement of dose reconstruction methodology for radiological accidents, having then more realist radiation doses. (author)

  9. The ratio between effective doses due to external exposure to electrons for tomographic and mathematical models; Razoes entre doses efetivas devido a exposicao externa de eletrons para modelos tomograficos e matematicos

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Fernando R.A. [Centro Regional de Ciencias Nucleares (CRCN), Recife, PE (Brazil)]|[Faculdade Boa Viagem (FBV), Recife, PE (Brazil)]. E-mail: falima@cnen.gov.br; Kramer, Richard; Khoury, Helen J. [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear]. E-mail: rkramer@uol.com.br; hjkhoury@globo.com; Vieira, Jose W. [Centro Federal de Educacao Tecnologica de Pernambuco (CEFET-PE), Recife, PE (Brazil)]. E-mail: jwvieira@br.inter.net; Yoriyaz, Helio [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: hyotiyaz@ipen.br; Loureiro, Eduardo C.M. [Universidade de Pernambuco, Recife, PE (Brazil). Escola Politecnica (POLI/UPE)]. E-mail: eduloureiro@uol.com.br

    2005-07-01

    The development of new, sophisticated Monte Carlo codes, and of tomographic or voxel based human phantoms motivated the International Commission on Radiological Protection (ICRP) to call for a revision of traditional exposure models, which have been used in the past to calculate organ and tissue as well as effective dose coefficients for stylized MIRD5- type phantoms. This paper reports about calculations made with the recently developed tomographic MAX (Male Adult voXel) and FAX (Female Adult voXel) phantoms, as well as with the gender-specific MIRD5-type phantoms ADAM and EVA, coupled to the EGS4 and to the MCNP4C Monte Carlo code, for external whole-body irradiation with electrons. Effective doses for the tomographic and for the stylized exposure models will be compared separately as function of the replacement of the Monte Carlo code, of human tissue compositions, and of the stylized by the tomographic anatomy. The results indicate that for external exposures to electrons the introduction of voxel-based exposure models causes changes of the effective dose between +40% and - 60% depending on the energies and geometries considered compared to corresponding data of the MIRD5-type phantoms. (author)

  10. Reasons between effective doses for tomographic and mathematical models due to external exposition by photons; Razoes entre doses efetivas para modelos tomograficos e matematicos devido a exposicoes externas a fotons

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, R.; Khoury, H.J. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Vieira, J.W. [Centro Federal de Educacao Tecnologica de Pernambuco (CEFET-PE), Recife, PE (Brazil); Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Lima, F.R.A. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Loureiro, E.C.M. [Escola Politecnica de Pernambuco (POLI/UPE), Recife, PE (Brazil)

    2005-07-01

    The development of Monte Carlo codes and new and sophisticated tomographic human models, or based on voxel, motivated the ICRP to propose a revision of the traditional exposition models, which have been used to calculate doses on organs and tissues using mathematical phantoms MIRD-type 5. This article presents calculations made with tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed and also, for comparison, with ADAM and Eve mathematician phantoms. All models were coupled to the EGS4 and MCNP4 codes for full body external irradiation by photons. It were simulated expositions AP, PA and rotational for energies varying between 10 keV and 10 MeV. The effective calculated doses were compared separately to evaluate: the replacement of the Monte Carlo code; the composition of the tissues and the replacement of tomographic phantoms by mathematical ones. Effective doses calculated results indicate that for external exposures by photons to introduce models based on voxels can cause a reduction of about 10% to the energies considered in this study.

  11. Ratios between effective doses for tomographic and mathematician models due to internal exposure of photons; Razoes entre doses efetivas para modelos tomograficos e modelos matematicos devido as exposicoes internas de fotons

    Energy Technology Data Exchange (ETDEWEB)

    Lima, F.R.A. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Kramer, R.; Khoury, H.J.; Santos, A.M. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Vieira, W. [Centro Federal de Educacao Tecnologica de Pernambuco (CEFET-PE), Recife, PE (Brazil); Loureiro, E.C.M. [Escola Politecnica de Pernambuco, Recife, PE (Brazil)

    2005-07-01

    The development of new and sophisticated Monte Carlo codes and tomographic human phantoms or voxels motivated the International Commission on Radiological Protection (ICRP) to revise the traditional models of exposure, which have been used to calculate effective dose coefficients for organs and tissues based on mathematician phantoms known as MIRD5. This paper shows the results of calculations using tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed by the authors as well as with the phantoms ADAM and EVA, of specific genres, type MIRD5, coupled to the EGS4 Monte Carlo and MCNP4C codes, for internal exposure with photons of energies between 10 keV and 4 MeV to several organs sources. Effective Doses for both models, tomographic and mathematician, will be compared separately as a function of the Monte Carlo code replacement, of compositions of human tissues and the anatomy reproduced through tomographs. The results indicate that for photon internal exposure, the use of models of exposure based in voxel, increases the values of effective doses up to 70% for some organs sources considered in this study, when compared with the corresponding results obtained with phantoms of MIRD-5 type.

  12. A methodology to establish the appearance of cancer cases due to radiation dose in compressed breast; Uma metodologia para comprovar o aparecimento de casos de cancer devido a dose de radiacao na mama comprimida

    Energy Technology Data Exchange (ETDEWEB)

    Feital, Joao Carlos Da Silva; Delgado, Jose Ubiratan; Peixoto, Jose Guilherme P.; Fonseca, Hugo Geraldo Da, E-mail: jfeital@ird.gov.br, E-mail: delgado@ird.gov.br, E-mail: guilherm@ird.gov.br, E-mail: hfonseca@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-10-01

    It is known that more than 20% of the world's population will contract some type of cancer. In Brazil, with the exception of skin cancer (non melanoma) the breast cancer ranks first among the higher frequency of tumours among women and in general, although the methods of detection are advancing in the year 2010 took place about 13 thousand deaths in about 50,000 cases, probably due to late detection of these neoplasm. New cases of breast cancer in a given population can be proven from absorbed dose quantity, calculated for the compressed breast, due to the risk by means of exposure to x rays in this radiodiagnostic practices. Methodology: Exposures were held in an ionization chamber and the other quantities required were obtained to the screen-film equipment of mammography. Results: Also experimental results were of compressed breast an equivalent dose of ( 1.82 mSv {+-} 0.2%) or (3.64 mSv {+-} 0.2%) for both projections, i.e. medium lateral oblique and cranio caudal. The experimental value obtained here is consistent with the calculated results and published in the literature for analog and CR equipment. Conclusion: From the result of dose equivalent in the breast, one can say that there will be effectively attesting as to the appearance of new cases of cancer if approximately 80 million women are exposed to radiation emitted by mammographers. (author)

  13. Collective dose estimation in Portuguese population due to medical exams of diagnostic radiology and nuclear medicine; Estimativa da dose coletiva na populacao portuguesa devido a exames medicos de radiologia de diagnostico e de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Teles, Pedro; Vaz, Pedro [Instituto Tecnologico e Nuclear, Sacavem (Portugal). Instituto Superior Tecnico; Sousa, M. Carmen de [Instituto Portugues de Oncologia de Coimbra (Portugal); Paulo, Graciano; Santos, Joana [Escola Superior de Tecnologia da Saude de Coimbra (Portugal); Pascoal, Ana [Kings College Hospital, London (United Kingdom). Kings Health Partners; Cardoso, Gabriela; Santos, Ana isabel [Hospital Garcia de Orta, Almada (Portugal); Lanca, Isabel [Administracao Regional de Saude, Coimbra (Portugal); Matela, Nuno [Universidade de Lisboa (Portugal). Fac. de Ciencias. Instituto de Biofisica e Engenharia Biomedica; Janeiro, Luis [Escola superior de Saude da Cruz Vermelha Portuguesa, Lisboa (Portugal); Sousa, Patrick [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, Lisboa (Portugal); Carvoeiras, Pedro; Parafita, Rui [Medical Consult, SA, Lisboa (Portugal); Simaozinho, Paula [Administracao Regional de Saude, Faro (Portugal)

    2013-11-01

    In order to assess the exposure of the Portuguese population to ionizing radiation due to medical examinations of diagnostic radiology and nuclear medicine, a working group, consisting of 40 institutions, public and private, was created to evaluation the coletive dose in the Portuguese population in 2010. This work was conducted in collaboration with the Dose Datamed European consortium, which aims to assess the exposure of the European population to ionizing radiation due to 20 diagnostic radiology examinations most frequent in Europe (the 'TOP 20') and nuclear medicine examinations. We obtained an average value of collective dose of Almost-Equal-To 1 mSv/caput, which puts Portugal in the category of countries medium to high exposure to Europe. We hope that this work can be a starting point to bridge the persistent lack of studies in the areas referred to in Portugal, and to enable the characterization periodic exposure of the Portuguese population to ionizing radiation in the context of medical applications.

  14. Avaliação da vibração e ruído ocupacionais no fresamento de pisos industriais

    OpenAIRE

    Gonçalves, Felyppe Blum

    2015-01-01

    A constante mudança nos meios de trabalho ocorre devido a evolução tecnológica e industrial. Entretanto, com o advento de tais inovações, dificilmente o trabalhador da indústria não é submetido aos mais variados riscos ocupacionais resultantes dos processos produtivos. Diante deste contexto, o presente estudo teve como objetivo principal avaliar os níveis de vibração e de ruído aos quais os trabalhadores de uma empresa do setor da construção civil, especializada na manutenção e reformas de pi...

  15. O devido processo legal no processo administrativo disciplinar

    OpenAIRE

    Piccina, Fernanda Vasconcelos Fontes

    2011-01-01

    O presente trabalho tem por objeto o estudo do devido processo legal e suas implicações no processo administrativo disciplinar. Parte-se da contextualização do Devido Processo Legal no ordenamento jurídico brasileiro e de uma breve descrição histórica do princípio e da sua análise, tomando por base o fenômeno da constitucionalização do Direito. O estudo do processo administrativo disciplinar é feito, inicialmente, a partir de abordagem geral desse processo na esfera federal, sob a ótica da...

  16. Determination of the equivalent doses due to the ingestion of radionuclides from the uranium and thorium series presents in drinking waters of the region of Santa Luzia, Paraiba state, Brazil; Determinacao das doses equivalentes devido a ingestao de radionuclideos das series do uranio e torio presentes em aguas de consumo do municipio de Santa Luzia, estado da Paraiba

    Energy Technology Data Exchange (ETDEWEB)

    Pastura, Valeria F. da S., E-mail: vpastura@cnen.gov.b [Comissao Nacional de Energia Nuclear (DRSN/CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioprotecao e Seguranca Nuclear. Coordenacao de Materias Primas e Minerais; Campos, Thomas F. da C.; Petta, Reinaldo A., E-mail: thomascampos@geologia.ufrn.b, E-mail: petta@geologia.ufrn.b [Universidade Federal do Rio Grande do Norte (LARANA/UFRN), Natal, RN (Brazil). Lab. de Radioatividade Natural

    2011-10-26

    This paper determined the original dose equivalents from radionuclides of uranium and thorium series in a drinking water of well which is supplied to the population of Santa Luzia, Paraiba state, Brazil. The collected waters are near to the mineralized phlegmatic bodies in rose quartz and amazonite feldspar. Radiometric measurements performed on the feldspar vein point out counting ratios surrounding 30000 cps and the analysis of collected samples of minerals presented tenors for the {sup 226}Ra and {sup 219}Pb varying from 0.50 to 2.30 Bq/sw. For determination of concentration of radionuclides U{sub Total}, {sup 226}Ra, {sup 228}Ra and {sup 219}Pb, found in the not desalinated, two methods were used, spectrophotometry with arsenazo and radiochemistry, both realized in the CNEN-LAPOC laboratories. For the calculation of dose equivalent it was taken into consideration the following parameters: the dose coefficients for incorporation by ingestion for public individuals with ages over 17 years (Norma CNEN-NN-3.01, Regulatory Position 3.01/011) and daily ingestion of 4 liters of water, which is over the recommended by the WHO of 2L/day - 1993. The obtained values were compared with the reference value for compromised dose equivalent established by WHO for evaluate the risk potential to the health of population, by ingestion. The radionuclide concentrations in the wells varies from 0.054 to 0.21 Bq/L, resulting dose equivalents of 3.94 x 10{sup -3} mSv/year and 0.17 mSv/year in the studied population

  17. The use of steel and lead shieldings in radiotherapy rooms and its comparison with respect to neutrons doses at patients; Comparacao de blindagens de aco e de chumbo usadas em salas de radioterapia quanto a dose devido a neutrons depositada em pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G., E-mail: maglosilva15@gmail.com, E-mail: rebello@ime.eb.br, E-mail: fisica.dna@gmail.com, E-mail: eng.cavaliere@gmail.com, E-mail: raphaelmsm@gmail.com, E-mail: kelmo.lins@gmail.com, E-mail: ggrprojetos@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Santos, R.F.G., E-mail: raphaelfgsantos@gmail.com [Centro Universitario Anhanguera, Niteroi, RJ (Brazil). Departamento de Engenharia; Silva, Ademir X., E-mail: ademir@con.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H*(10){sub n}, within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5x5cm{sup 2}, 10x10cm{sup 2}, 20x20cm{sup 2}, 30x30cm{sup 2} and 40x40cm{sup 2} openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H*(10){sub n} at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation.

  18. Gonalgia entre trabalhadores e fatores ocupacionais associados: uma revisão sistemática

    OpenAIRE

    Silva,Marcelo Cozzensa da; Fassa,Anaclaudia Gastal; Domingues,Marlos Rodrigues; Kriebel,David

    2007-01-01

    Com o objetivo de reunir informações sobre gonalgia entre trabalhadores e fatores ocupacionais associados, foi realizada uma revisão sistemática nas bases de dados MEDLINE, LILACS, SciELO, Free Medical Journals, entre outros, referentes ao período 1990-2006, usando-se os descritores gonalgia, knee, knee pain, knee joint, knee dislocation, knee injuries, work, workplace, workload, employment, occupations, industry, occupational, workers, arthrosis, osteoarthritis e seus equivalentes em portugu...

  19. Riscos e doenças ocupacionais relacionados ao exercício da anestesiologia

    Directory of Open Access Journals (Sweden)

    Daniel Volquind

    2013-04-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: O exercício da anestesiologia não é isento de riscos para o anestesiologista. Considerada um local de trabalho insalubre em razão dos riscos potenciais que oferece, a sala de operações (SO é o local no qual o anestesiologista passa a maior parte do tempo. Nesta revisão, propomos uma análise dos riscos ocupacionais aos quais estão expostos os anestesiologistas em sua prática diária. CONTEÚDO: Apresentamos a classificação dos riscos e suas relações com as doenças ocupacionais. CONCLUSÃO: O controle dos riscos ocupacionais, aos quais os anestesiologistas são expostos diariamente, se faz necessário para o desenvolvimento de um local de trabalho adequado e com riscos reduzidos para a boa prática da anestesiologia. Isso contribui para a diminuição do absenteísmo, a melhora da assistência prestada ao paciente e da qualidade de vida do anestesiologista.

  20. Trabalho docente: que aspectos sociodemográficos e ocupacionais predizem o bem-estar subjetivo?

    OpenAIRE

    Chaves, Sandra Souza da Silva; Fonsêca, Patrícia Nunes da

    2006-01-01

    Este estudo objetivo conhecer quais os aspectos sociodemográficos e ocupacionais que melhor predizem o bem-estar subjetivo de professores das escolas públicas e privadas do estado da Paraíba que estão cursando pedagogia em regime especial. Participaram 313 professores, que responderam a escala de afetos positivos e negativos, a escala de vitalidade, o questionário de saúde geral - QSG-12 e a escala de satisfação com a vida e perguntas socioocupacionais. Dentre os resultados encontrados, desta...

  1. Riscos ocupacionais em UTI: proteção específica

    Directory of Open Access Journals (Sweden)

    Maria da Natividade Abreu da Costa

    1989-12-01

    Full Text Available Aponta os riscos ocupacionais que a equipe multiprofissional se expõe diariamente. Na tentativa de minimizar os riscos existentes são traçadas medidas de proteção especffica que se estendem desde a planta física ao preparo técnico dos funcionários. São utilizadas como variáveis o trinomio ambiente/paciente/equipe de enfermagem, relacionando assim os riscos e a proteção específica.

  2. Associações entre auto-eficácia para atividades ocupacionais e interesses em adolescentes

    OpenAIRE

    Nunes,Maiana Farias Oliveira; Noronha,Ana Paula Porto

    2011-01-01

    O objetivo desse estudo foi analisar a relação entre a auto-eficácia para atividades ocupacionais e suas fontes e interesses, construtos importantes no contexto da Orientação Profissional. Participaram da pesquisa 289 adolescentes, do estado de São Paulo, que responderam a Escala de Auto-eficácia para Atividades Ocupacionais-EAAOc e o Self-Directed Search e 107 alunos que responderam a EAAOc e a Escala de Aconselhamento Profissional. Houve correlações significativas entre auto-eficácia e inte...

  3. Ergonomia e as atividades ocupacionais da equipe de enfermagem Ergonomics and the occupacional activities of the nursing staff

    Directory of Open Access Journals (Sweden)

    Neusa Maria Costa Alexandre

    1998-04-01

    Full Text Available Esse trabalho discute determinadas condições ergonômicas do trabalho que causam lesões no sistema músculo-esquelético da coluna vertebral, relacionando-as com as atividades ocupacionais da equipe de enfermagem.This paper discusses some of the ergonomics conditions that contribute to the development of musculoskeletal disorders of the vertebral column and relates these conditions to the occupational activities of the nursing staff.

  4. Trabalho docente: que aspectos sociodemográficos e ocupacionais predizem o bem-estar subjetivo?

    Directory of Open Access Journals (Sweden)

    Chaves, Sandra Souza da Silva

    2006-01-01

    Full Text Available Este estudo objetivo conhecer quais os aspectos sociodemográficos e ocupacionais que melhor predizem o bem-estar subjetivo de professores das escolas públicas e privadas do estado da Paraíba que estão cursando pedagogia em regime especial. Participaram 313 professores, que responderam a escala de afetos positivos e negativos, a escala de vitalidade, o questionário de saúde geral - QSG-12 e a escala de satisfação com a vida e perguntas socioocupacionais. Dentre os resultados encontrados, destacam-se o grau de satisfação no trabalho, o grau de percepção de reconhecimento da equipe escolar e dos pais dos alunos e estado civil como variáveis preditoras de bem-estar. Sugerem-se replicação do estudo com estudantes de pedagogia que não estejam realizando o curso em regime especial, e ainda, com professores já estabilizados no mercado de trabalho, com formação superior que não necessitem buscar um título para manter-se no emprego

  5. A ginástica laboral como fator preventivo às doenças ocupacionais (LER/DORT)

    OpenAIRE

    Lourenço, Rodolfo Motta

    2012-01-01

    A Ginástica Laboral pode ser definida como um conjunto de atividades físicas criadas a partir da necessidade profissional que os trabalhadores exercem durante a sua jornada de trabalho, para que possa compensar as estruturas físicas mais utilizadas durante o expediente, visando relaxar, tonificar e ativar as que não são tão requeridas, dessa forma, prevenido às chamadas doenças ocupacionais O presente estudo tem como objetivo verificar a importância da Ginástica Laboral como fator preventivo ...

  6. Estratégia saúde da família: riscos ocupacionais dos auxiliares e técnicos de enfermagem

    OpenAIRE

    Ferraz, Lucimare; Kessler, Marciane; Krauzer, Ivete Maroso; Trindade, Letícia de Lima; Silva, Olvani Martins da

    2015-01-01

    Os profissionais da enfermagem estão expostos a inúmeros riscos ocupacionais, advindos das condições inerentes ao ambiente e ao processo de trabalho. O objetivo deste estudo é identificar os riscos ocupacionais e agravos à saúde no ambiente de trabalho dos técnicos e auxiliares de enfermagem da Estratégia de Saúde da Família. Pesquisa quantitativa, realizada com técnicos e auxiliares de enfermagem de 13 unidades de Estratégia de Saúde da Família. Os dados foram coletados por meio de entrevist...

  7. Acidentes do Trabalho Relacionados a Transtornos Psicológicos Ocupacionais

    OpenAIRE

    Kamimura, Quésia Postigo; Tavares, Renata Silva Cardoso Rocha

    2012-01-01

    Devido às transformações no mundo do trabalho do século XXI, a carga psicológica exigida dos profissionais não condiz com a exigida para uma vida saudável. Os registros de acidentes/doenças de trabalho vêm aumentando no decorrer dos anos, impactando nos índices de doenças referentes aos transtornos psicológicos. Tem-se como objetivo apresentar um levantamento do número de acidentes de trabalho referentes a transtornos psicológicos, de 2005 a 2008. Foi realizada uma pesquisa bibliográfica sobr...

  8. Fibromialgia: aspectos clínicos e ocupacionais Fibromyalgia: clinical and occupational aspects

    Directory of Open Access Journals (Sweden)

    Milton Helfenstein Junior

    2012-06-01

    Full Text Available A fibromialgia (FM é uma síndrome clínica comumente observada na prática médica diária e possui etiopatogenia ainda obscura. Caracterizada por quadro de dor musculoesquelética crônica associada a variados sintomas, a FM pode ser confundida com diversas outras doenças reumáticas e não reumáticas, quando estas cursam com quadros de dor difusa e fadiga crônica. O tratamento da FM deve ser multidisciplinar, individualizado, contar com a participação ativa do paciente e basear-se na combinação das modalidades não farmacológicas e farmacológicas. Presente tanto em ambientes laborais como não laborais, não há evidência científica na literatura de que a FM possa ser causada pelo trabalho. A FM comumente não leva à incapacidade laborativa. Nos casos em que a dor ou a fadiga não respondem ao tratamento adequado, atingindo níveis significativos, o afastamento do trabalho por curto período de tempo pode ser considerado. Pela relevância do tema, os autores elaboraram este artigo de revisão a partir de investigação exploratória, qualitativa e bibliográfica com objetivo de estudar os principais aspectos clínicos e ocupacionais da FM, dando ênfase ao embasamento teórico-conceitual e na experiência de especialistas.Fibromyalgia (FM is a clinical syndrome commonly observed in daily medical practice and its etiopathogenesis is still unclear. As it is characterized by chronic musculoskeletal pain associated with several symptoms, FM may be confused with several other rheumatic and nonrheumatic diseases when they course with pictures of diffuse pain and chronic fatigue. FM treatment should be multidisciplinary, individualized, count on active participation of the patient, and based on combined pharmacological and nonpharmacological modalities. It is found both in work and non-work settings, and there is no scientific evidence in the literature showing that FM might be caused by occupation. FM seldom leads to incapacity to work

  9. Riscos ocupacionais de uma indústria calçadista sob a ótica dos trabalhadores

    Directory of Open Access Journals (Sweden)

    Fernanda Reinher da Luz

    2013-02-01

    Full Text Available O estudo teve como objetivo identificar os riscos ocupacionais de uma indústria calçadista sob a ótica dos trabalhadores, bem como as medidas preventivas adotadas por eles contra os riscos. Realizou-se um estudo qualitativo, descritivo. A amostra foi composta por quinze trabalhadores. Os dados foram coletados por entrevista semiestruturada e analisados à luz da análise de conteúdo. Foram respeitados os aspectos éticos e a pesquisa foi aprovada pelo Comitê de Ética em Pesquisa da Universidade Regional do Noroeste do Estado do Rio Grande do Sul. Os resultados apontam que os trabalhadores são conhecedores dos riscos do seu processo de trabalho, faziam uso de medidas de proteção individual e a empresa disponibilizava dispositivos de segurança, informando e realizando, periodicamente, visitas aos setores, na perspectiva de desenvolver ações educativas.

  10. A velhice nas telas do cinema: um olhar sobre a mudança dos papéis ocupacionais dos idosos

    Directory of Open Access Journals (Sweden)

    Carla da Silva Santana

    2013-12-01

    Full Text Available Dado o aumento da produção cinematográfica sobre a velhice, este estudo buscou identificar as modificações nos papéis ocupacionais dos idosos e como estes são representados nos filmes. Trata-se de um estudo documental, qualitativo, que utilizou filmes tendo como personagem principal um sujeito velho. Estes foram classificados por gênero e aplicou-se a Lista de Papéis Ocupacionais. Dos 23 filmes analisados, identificaram-se os papéis perdidos, mantidos e incorporados na velhice, assim como os conflitos diante da mudança como a falta de projetos de vida.  

  11. Gonalgia entre trabalhadores e fatores ocupacionais associados: uma revisão sistemática Knee pain and associated occupational factors: a systematic review

    OpenAIRE

    Marcelo Cozzensa da Silva; Anaclaudia Gastal Fassa; Marlos Rodrigues Domingues; David Kriebel

    2007-01-01

    Com o objetivo de reunir informações sobre gonalgia entre trabalhadores e fatores ocupacionais associados, foi realizada uma revisão sistemática nas bases de dados MEDLINE, LILACS, SciELO, Free Medical Journals, entre outros, referentes ao período 1990-2006, usando-se os descritores gonalgia, knee, knee pain, knee joint, knee dislocation, knee injuries, work, workplace, workload, employment, occupations, industry, occupational, workers, arthrosis, osteoarthritis e seus equivalentes em portugu...

  12. O direito criminal pós-positivista e o devido processo penal constitucional

    OpenAIRE

    Balico, Vladimir

    2008-01-01

    O presente trabalho analisa a hermenêutica do direito no âmbito criminal, à luz da Constituição Federal, em um Estado Constitucional e Democrático de Direito, que tem como idéia síntese a dignidade da pessoa humana. A idéia de Justiça passa pelo conceito de proporcionalidade, vale dizer, não há interpretação possível fora do texto constitucional, notadamente em matéria criminal, que atribua a cada um o que lhe é devido, na medida do seu merecimento, sem que se faça a ponderação dos valores em...

  13. Riscos ocupacionais e adesão a precauções-padrão no trabalho de enfermagem em terapia intensiva: percepções de trabalhadores

    Directory of Open Access Journals (Sweden)

    Elisa Gomes Nazario

    Full Text Available Resumo Introdução: o trabalho em unidades de terapia intensiva proporciona grande exposição a riscos ocupacionais. Objetivos: conhecer a percepção de trabalhadores de enfermagem de terapia intensiva sobre os riscos ocupacionais a que estão expostos e sobre as Precauções-Padrão (PP e descrever os fatores que interferem, ou não, na adesão às PP recomendadas. Método: estudo de abordagem qualitativa, descritivo exploratório, com doze trabalhadores de enfermagem de duas unidades de terapia intensiva, realizado entre julho e setembro de 2015. Foi utilizada entrevista semiestruturada e análise de conteúdo temática. Resultados: os riscos psicológicos ou emocionais, químicos, biológicos e ergonômicos foram os mais percebidos. Em relação às PP, os trabalhadores indicam que existe adesão, mas não integralmente, principalmente no uso de EPIs. Identificaram-se como fatores favoráveis à adesão das PP a disponibilização de materiais de proteção e a conscientização e, como desfavoráveis, sentimento de autoconfiança, estrutura das unidades e organização do trabalho, quantitativo de funcionários, carga de trabalho, pressa, intercorrências e tempo prolongado para diagnóstico de pacientes com doenças infectocontagiosas. Conclusão: apesar das questões pessoais envolvidas na percepção dos riscos ocupacionais e na decisão de utilizar ou não as PP, as autoras entendem que é possível potencializar os fatores que favorecem a adesão.

  14. Análise dos fatores de riscos ocupacionais do trabalho de enfermagem sob a ótica dos enfermeiros

    Directory of Open Access Journals (Sweden)

    Nei Santos Duarte

    Full Text Available Estudo com abordagem quantitativa e descritiva, com objetivo de identificar, na percepção dos enfermeiros chefes de unidades de internação de um hospital universitário, os riscos ocupacionais a que estão expostos. A população foi composta de 30 enfermeiros, chefes de unidade de internação. Na coleta de dados, utilizou-se um questionário estruturado proposto no Guia de Avaliação de Riscos nos Locais de Trabalho de Boix e Vogel (1997, adaptado para a aplicação em estabelecimentos de saúde por Mauro (2001. Os resultados evidenciaram que os fatores de riscos atuam sobre os trabalhadores, propiciando um ambiente desfavorável para a realização das atividades, podendo comprometer a saúde e a vida profissional destes. As variáveis predominantes foram o ambiente e a manutenção preventiva inadequados e os equipamentos de proteção individual e coletiva insuficientes e/ou inadequadamente utilizados pelos profissionais, constrangimentos ergonômicos pela manipulação de carga e postura corporal inadequadas na realização das tarefas, e ritmo de trabalho acelerado pela falta de recursos material e humano. Ressalta-se que a pesquisa proporcionou um diagnóstico referente aos riscos presentes nos ambientes de trabalho da enfermagem, proporcionando um modo operatório eficaz com menor risco de acidentes no processo de trabalho, ambientes menos insalubres e maior satisfação para o profissional e os clientes.

  15. Riscos ocupacionais e gestão ergonómica em postos de trabalho com utilização de equipamento informático

    OpenAIRE

    Neto, Signalda de Sousa

    2015-01-01

    Os riscos ocupacionais têm sido uma problemática nos postos de trabalho dotados de visor. Esta problemática carece de um estudo mais aprofundado, uma vez que a prevenção contínua contribui para o sucesso dos locais de trabalho. Este estudo pretende descrever a incidência/prevalência dos riscos laborais a que os profissionais cuja atividade requer o uso de equipamento de informática estão expostos. O objeto de estudo concentra a recolha de várias informações nos colaboradores, d...

  16. Public exposure due to the transport of radiopharmaceuticals; Exposicao do publico devido ao transporte de radiofarmacos

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Demerval L.; Carneiro, Janete C.G.G.; Sanches, Matias P.; Sordi, Gian Maria A.A., E-mail: dlrodri@ipen.b, E-mail: janetegc@ipen.b, E-mail: msanches@ipen.b, E-mail: gsordi@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper estimate the radiological impact resulting from radiopharmaceuticals transport from the IPEN to some destinations defined a priori. So, doses were estimated in the public individuals, which are in the streets and vehicles that transit near the public transport, alongside the itinerary went through by packages, during the realization of radiopharmaceuticals transport

  17. Riscos ocupacionais para o câncer de laringe: um estudo caso-controle Occupational risks for laryngeal cancer: a case-control study

    Directory of Open Access Journals (Sweden)

    Sergio Guerra Sartor

    2007-06-01

    Full Text Available O tabagismo e o consumo de álcool são os fatores de risco mais bem estabelecidos para o câncer de laringe. Com relação aos fatores ocupacionais, o único carcinógeno estabelecido é a exposição a névoas de ácidos inorgânicos fortes. Entretanto, asbesto, pesticidas, tintas, gases de combustão de gasolina e diesel e poeiras, entre outros, aparecem na literatura como agentes ocupacionais que aumentam o risco de câncer de laringe. Um estudo caso-controle de base hospitalar foi conduzido para investigar fatores de risco ocupacionais para câncer de laringe. Foram coletadas informações detalhadas sobre tabagismo, consumo de álcool e história ocupacional de 122 casos de câncer de laringe e 187 controles pareados por freqüência (segundo sexo e idade. Encontrou-se risco aumentado de câncer de laringe nos indivíduos com exposição à sílica cristalina livre respirável (OR = 1,83; IC95%: 1,00-3,36, à fuligem (de carvão mineral, coque, madeira, óleo combustível (OR = 1,78; IC95%: 1,03-3,03, a fumos em geral (OR = 2,55; IC95%: 1,14-5,67 e a animais vivos (OR = 1,80; IC95%: 1,02-3,19.The most solidly established risk factors for laryngeal cancer are tobacco and alcohol. As for occupational factors, the only established carcinogen is exposure to strong inorganic acid mists. However, asbestos, pesticides, paints, gasoline, diesel engine emissions, dusts, and other factors have been reported in the literature as occupational agents that increase the risk of laryngeal cancer. A hospital-based case-control study was conducted to investigate occupational risk factors for laryngeal cancer. Detailed data on smoking, alcohol consumption, and occupational history were collected for 122 laryngeal cancers and 187 controls matched by frequency (according to sex and age. Laryngeal cancer was associated with exposure to respirable free crystalline silica (OR = 1.83; 95%CI: 1.00-3.36, soot (from coal, coke, fuel oil, or wood (odds ratio - OR = 1

  18. Coeficientes de modificação das propriedades mecânicas da madeira devidos à temperatura

    OpenAIRE

    Manríquez Figueroa, Manuel Jesús

    2012-01-01

    Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil As propriedades mecânicas da madeira à temperatura ambiente estão relacionadas, principalmente, com a densidade, a anatomia e o teor de umidade desse material. Quando ela é submetida a altas temperaturas, essas propriedades são completamente alteradas. Nessa situação, a resistência mecânica, as propriedades térmicas e a rigidez são afetadas devido à transição vítrea ...

  19. The occupational roles of women with anorexia nervosa Los papeles ocupacionales de mujeres con anorexia nervosa Os papéis ocupacionais de mulheres com anorexia nervosa

    Directory of Open Access Journals (Sweden)

    Leila Maria Quiles-Cestari

    2012-04-01

    configuram os papéis ocupacionais de pessoas com anorexia nervosa. A casuística foi composta por 11 mulheres adultas, diagnosticadas em tratamento no grupo de assistência em transtornos alimentares de um hospital de Ribeirão Preto, Brasil, e por um grupo-controle. Foram coletados dados sociodemográficos, antropométricos e aplicada a Lista de Identificação de Papéis Ocupacionais. Os resultados mostraram que houve alteração significativa nas mulheres com anorexia nervosa, com perda de papéis em relação ao padrão de desempenho do papel de trabalhador, voluntário, amigo e passatempo/amador, corroborando os prejuízos psicossociais decorrentes desse transtorno mental. A avaliação dos papéis ocupacionais no tratamento dos transtornos alimentares é estratégia importante para o planejamento de atividades de Terapia Ocupacional, fornecendo subsídios para a construção de espaços mais saudáveis, onde o fazer cria possibilidades de resgate dos papéis ocupacionais, independência e autonomia.

  20. Aborto em bovinos devido à intoxicação por Tetrapterys acutifolia (Malpighiaceae

    Directory of Open Access Journals (Sweden)

    Saulo A. Caldas

    2011-09-01

    Full Text Available Esse estudo teve por objetivo demonstrar experimentalmente que Tetrapterys acutifolia Cav. (fam. Malpighiaceae é capaz de provocar aborto em bovinos e caracterizar as alterações clínico-patológicas nas vacas e nos fetos. Estas plantas são responsáveis por significativo número de mortes em bovinos com mais de um ano de idade, especialmente nos Estados de Rio de Janeiro e São Paulo, mas até agora não havia sido comprovado experimentalmente seu efeito abortivo em bovinos. Os experimentos foram realizados no município de Barra do Piraí, RJ. Quatro vacas de descarte receberam brotos e folhas novas frescas de T. acutifolia, coletadas em propriedades vizinhas, nas doses de 2,5g/kg/dia, 5,0g/kg/dia (2 vacas e 10g/kg/dia, até ocorrer o abortamento. O quadro clínico nas vacas caracterizou-se por arritmia cardíaca, tremores musculares, anorexia, ascite, jugular ingurgitada, edema de peito e barbela e aborto (23-76 dias após o início da ingestão da planta; todas as vacas abortaram. Das quatro vacas apenas uma (a que recebeu 10g/kg/dia morreu 36 dias após o abortamento, com sintomas de insuficiência cardíaca. O exame necroscópico dos fetos/natimortos revelou hidrotórax, hidropericárdio, hidroperitônio e congestão hepática; ao corte do miocárdio, verificaram-se áreas pálidas. No exame histológico havia edema intersticial com fibrose incipiente. Na vaca que recebeu a maior dose e foi a óbito, bem como em outra intoxicada naturalmente, os achados de necropsia foram similares aos observados nos fetos, exceto pela dilatação dos vasos da base do coração e mais acentuada palidez do miocárdio. Observaram-se ainda edema subcutâneo nas regiões cervical e esternal, bem como veias jugulares ingurgitadas. Os achados histopatológicos foram necrose e edema intersticial com acentuada fibrose no miocárdio, espongiose da substância branca do encéfalo e, no fígado, congestão e leve fibrose. Adicionalmente, observou-se na vaca

  1. Severidades Ocupacionais associadas à inatividade física no lazer em trabalhadores Occupational severities associated to leisure time physical inactivity level in workers

    Directory of Open Access Journals (Sweden)

    Camila Bosquiero Papini

    2010-09-01

    Full Text Available O objetivo do estudo foi verificar associações entre severidades ocupacionais e nível de atividade física no lazer em trabalhadores. Para isso participaram do estudo 200 trabalhadores (71 homens e 129 mulheres do Município de Rio Claro e região. Foram avaliados o nível de atividade física no lazer (ativo ou inativo e algumas severidades ocupacionais. A análise estatística revelou que o tempo da jornada diária de trabalho, realização de horas extra e intensidade do trabalho não foram associados à inatividade física no lazer em trabalhadores. Somente a disposição no fim da jornada de trabalho foi associada à inatividade física no lazer, mostrando que trabalhadores que tem alguma disposição depois do trabalho são mais ativos no tempo de lazer.The aim of this study was to verify associations between occupational severities and leisure time physical inactivity level in workers. Two-hundred workers of Rio Claro County participated in this study. The leisure time physical activity (active or inactive and some occupational severities were evaluated. The statistic analyses showed that working day, overtime work and occupational intensity had not been associated with leisure time physical inactivity in workers. Only the willingness at the end of the working day had been associated to the leisure time physical inactivity; showing that workers who leave their work with some willingness have more possibilities to be active in leisure time.

  2. Suggestion of an inverse relationship between perception of occupational risks and work-related injuries Sugestão de uma associação inversa entre percepção de riscos ocupacionais e acidentes do trabalho

    Directory of Open Access Journals (Sweden)

    Ricardo Cordeiro

    2002-02-01

    Full Text Available Worker perception of risk influences worker behavior and consequently exposure to risks. However, an inverse relationship between perception of occupational risks and work-related injuries has not yet been clearly established. A matched case-control was performed aiming to investigate possible differences in perception of occupational risks between workers who had suffered occupational injuries and those who had not. Cases were defined as all 93 workers from a large metallurgical factory in southeastern Brazil, who had suffered occupational injuries during the year 1996. Controls were 372 workers who had not suffered occupational injuries, matched on the basis of the factory sector and jobs performed. Assessment of occupational risk perception was performed by asking the workers to fill out a questionnaire consisting of questions on specific risks related to problems in work relations, work per se, and mode of production. The findings suggest that the degree of perception that workers with occupational injuries have of some occupational risks is lower than that of their non-injured coworkers.A percepção que o trabalhador tem dos riscos ocupacionais a que está exposto, influencia seu comportamento e sua própria exposição a riscos. Entretanto, uma relação inversa entre percepção de riscos ocupacionais e acidentes do trabalho, embora especulada, não foi ainda claramente estabelecida. Este é um estudo caso-controle objetivando investigar a existência de diferenças na percepção de riscos ocupacionais entre trabalhadores acidentados e não acidentados. Os casos foram todos os 93 trabalhadores de uma grande metalúrgica de Botucatu, que sofreram acidentes do trabalho no ano de 1996. Para cada caso foram aleatoriamente alocados quatro controles não acidentados, emparelhados segundo a seção de trabalho e a função do trabalhador acidentado na semana do acidente. A mensuração da percepção de riscos ocupacionais de casos e controles

  3. Escala de auto-eficácia para atividades ocupacionais: construção e estudos exploratórios

    Directory of Open Access Journals (Sweden)

    Maiana Farias Oliveira Nunes

    2008-01-01

    Full Text Available Esse estudo visou a construção e validação de uma escala de avaliação da auto-eficácia para atividades ocupacionais e as fontes de auto-eficácia associadas (EAAOc, para uso em Orientação Profissional. O processo de construção foi iniciado pela revisão teórica, tendo passado por testagem piloto, análise de especialistas e verificação da estrutura e da consistência interna. Participaram 333 adolescentes matriculados no ensino médio de escolas públicas e particulares do estado de São Paulo-Brasil. Foram observadas evidências de validade de conteúdo favoráveis, por meio da alta concordância entre juízes e expectativa teórica. A solução fatorial de três fatores apresentou maior coerência teórica, com os fatores Experiência Pessoal Direta, Aprendizagem Vicária e Persuasão Verbal, com alphas de Cronbach 0,88; 0,62 e 0,72, respectivamente. São discutidas possibilidades de uso e limitações da EAAOc.

  4. Associações entre auto-eficácia para atividades ocupacionais e interesses em adolescentes Associations between self-efficacy to occupational activities and interests in adolescents

    Directory of Open Access Journals (Sweden)

    Maiana Farias Oliveira Nunes

    2011-01-01

    Full Text Available O objetivo desse estudo foi analisar a relação entre a auto-eficácia para atividades ocupacionais e suas fontes e interesses, construtos importantes no contexto da Orientação Profissional. Participaram da pesquisa 289 adolescentes, do estado de São Paulo, que responderam a Escala de Auto-eficácia para Atividades Ocupacionais-EAAOc e o Self-Directed Search e 107 alunos que responderam a EAAOc e a Escala de Aconselhamento Profissional. Houve correlações significativas entre auto-eficácia e interesses (r entre - 0,25 e 0,27. A auto-eficácia Realista e Social, juntamente com a variável sexo, apresentou capacidade preditiva significativa para os respectivos tipos de interesses. É discutida a coerência da associação entre os tipos de auto-eficácia para atividades ocupacionais e os respectivos tipos de interesses.The aim of this study was to analyze the association between self-efficacy for occupational activities and its sources and interest, which are important constructs for Vocational Guidance. Two hundred eighty nine adolescents answered the Self-efficacy Scale for Occupational Activities (SSOA and the Self-Directed Search, and 107 answered the SSOA and the Professional Counseling Scale. All participants lived in São Paulo at the moment of the survey. There were significant correlations between self-efficacy and interests (r ranging from -0.25 to 0.27. Realistic and Social self-efficacy combined with gender showed a significant predictive power to their respective types of interest. We discussed the coherence between self-efficacy for occupational activities and their respective interests.

  5. Trabalho precoce e acidentes ocupacionais na adolescência Trabajo precoz y accidentes de trabajo en la adolescencia Child labor and occupational accidents in the adolescence

    Directory of Open Access Journals (Sweden)

    Márcia Elena Andrade Santos

    2009-12-01

    Full Text Available Estudo transversal, descritivo e quantitativo, com o objetivo de investigar a ocorrência de acidentes ocupacionais em adolescentes trabalhadores. Realizado de abril a agosto de 2008, com uma amostra aleatória de 308 adolescentes entre 14 e 18 anos de idade. Os resultados evidenciaram que 168 (54,5% eram trabalhadores, 42%, desses, alegaram ter sofrido acidentes típicos, (18,5% acidentes de trajeto, 14,9% afastaram-se do trabalho, 51,4% não tinham carteira assinada e a maioria era do sexo masculino. Os cortes e perfurações foram os acidentes mais ocorridos (27,5%, a queimadura constituiu o principal agravo (26,9% e as partes do corpo mais afetadas foram mãos e dedos (40,4%. Conclui-se que os acidentes ocupacionais configuram-se como uma expressão da violência contra os jovens trabalhadores e um grave problema de Saúde Pública. Deve ser incorporado com prioridade na agenda dos serviços públicos e o enfermeiro, junto à equipe de saúde, podem ser os principais articuladores desse processo.Estudio transversal, descriptivo y cuantitativo, que tiene como finalidad investigar la ocurrencia de accidentes de trabajo en los trabajadores jóvenes. Realizado entre abril y agosto del 2008, con una muestra aleatoria de 308 adolescentes de 14 y 18 años de edad. Los resultados mostraron que 168 (54,5% eran trabajadores, el 42% de éstos afirma haber sufrido accidentes típicos, 18,5% fueron accidentes de trayecto, el 14,9% no pudieron trabajar después del accidente, el 51,4% no tenía un contrato formal de trabajo y la mayoría era del sexo masculino. Cortes y pinchazos fueron los accidentes con mayor incidencia (27,5%, la quemadura fue la lesión principal (26,9% y las partes del cuerpo más afectadas fueron las manos y los dedos (40,4%. Se concluyó que los accidentes de trabajo se caracterizan como una expresión de la violencia contra los trabajadores jóvenes y como un grave problema de salud pública. Por lo tanto, esta cuestión deber

  6. Gonalgia entre trabalhadores e fatores ocupacionais associados: uma revisão sistemática Knee pain and associated occupational factors: a systematic review

    Directory of Open Access Journals (Sweden)

    Marcelo Cozzensa da Silva

    2007-08-01

    Full Text Available Com o objetivo de reunir informações sobre gonalgia entre trabalhadores e fatores ocupacionais associados, foi realizada uma revisão sistemática nas bases de dados MEDLINE, LILACS, SciELO, Free Medical Journals, entre outros, referentes ao período 1990-2006, usando-se os descritores gonalgia, knee, knee pain, knee joint, knee dislocation, knee injuries, work, workplace, workload, employment, occupations, industry, occupational, workers, arthrosis, osteoarthritis e seus equivalentes em português e espanhol. Dos 2.263 estudos inicialmente encontrados, somente 26 cumpriram os critérios necessários para permanecer na revisão. As prevalências de gonalgia nos últimos 12 meses variaram entre 11,2% e 60,9%, e os principais fatores associados foram: sexo feminino, idade avançada, índice de massa corporal elevado, trabalhar ajoelhado e carregar peso no trabalho.In order to collect information on knee pain and associated occupational factors, a systematic review was conducted using the MEDLINE, LILACS, SciELO, and Free Medical Journals databases, from 1990 to 2006. Key words were: gonalgia, knee, knee pain, knee joint, knee dislocation, knee injuries, work, workplace, workload, employment, occupations, industry, occupational, workers, arthrosis, and osteoarthritis. Equivalent terms in Portuguese and Spanish were also used. From the initial 2,263 studies gathered, only 26 met the review's inclusion criteria. Knee pain prevalence in the previous 12 months ranged from 11.2% to 60.9%. The main associated factors were: female gender, older age, high body mass index, kneeling working position, and lifting at work.

  7. Microaspersores entupidos devido a problemas de ferro na água Microsprinkler clogged due to iron problems in the water

    Directory of Open Access Journals (Sweden)

    Túlio Assunção Pires Ribeiro

    2008-08-01

    Full Text Available Um dos aspectos relevantes a ser considerado no manejo da irrigação é a uniformidade de distribuição de água pelo sistema. Este trabalho foi desenvolvido com o objetivo de avaliar a eficiência da cloração com a utilização de hipoclorito de sódio na desobstrução de microaspersores devido à utilização de águas com elevado teor de ferro. Um sistema com dez meses de uso apresentava setores com vazões de 5% a 57% menores que a vazão de projeto. Foi feito o tratamento químico da água de irrigação, utilizando-se hipoclorito de sódio com 12% de cloro livre na dosagem de 100 mg L-1 e ácido sulfúrico, na concentração de 98%, para manter o pH da água de irrigação em torno de 4,5. O resultado indicou que houve aumento significativo nas vazões médias dos microaspersores em todos os setores avaliados e diminuição na variação da vazão dos mesmos com relação à estimada no projeto.An important aspect to be considered in irrigation managment is the uniformity distribution of water through the irrigation system. This research had the objective to evaluate the efficiency of chlorination in the use of sodium hypochlorite in clearing of microsprinkler due to the presence of high iron concentration in water. The equipment with less than a year of use presenting sectors with 5% and 57% lower flow than the original project flow. The chemical treatment of water irrigation utilized sodium hypochlorite with 12% free chlorine on 100mg L-1 concentration, and sulphuric acid 98% to maintain the pH of water irrigation about 4.5. The result demonstrated a significant increase in the average flow of the microsprinkler's variation in all evaluted setors, and decrease in their flow variation related to the estimated in the project.

  8. NOVAS PERSPECTIVAS DA RESPONSABILIDADE PROCESSUAL NO BRASIL: O PRINCÍPIO DA BOA-FÉ OBJETIVA E O DEVIDO PROCESSO LEGAL

    Directory of Open Access Journals (Sweden)

    Thiago Rodrigues de Pontes Bomfim

    2016-09-01

    Full Text Available O presente estudo busca, inicialmente, demonstrar o caráter normativo dos princípios constitucionais, bem como seu papel no que acaba por se transformar em uma nova ordem processual, para, por fim, uma vez reconhecido o caráter de princípio jurídico à boa-fé objetiva, situar seu fundamento constitucional em um novo conceito de devido processo legal.

  9. Aplicação de programa educativo multidisciplinar em gestações de alto risco devido a doenças endócrinas

    OpenAIRE

    Feitosa,Alina Coutinho Rodrigues; Queiroz,Ana Maria; Vianna,Adriana Matos; Schleu,Minna

    2010-01-01

    OBJETIVO: avaliar a aplicação de um programa de intervenção multidisciplinar educativo em mulheres com gestação de alto risco devido a doenças endócrinas. MÉTODOS: avaliamos retrospectivamente a aplicação de um programa educativo multidisciplinar em 185 gestantes com doenças endócrinas referenciadas para uma maternidade especializada em gestação de alto risco. As gestantes receberam atenção pré-natal multidisciplinar por times compostos por endocrinologistas, obstetras, ultrassonografistas, e...

  10. Tabagismo no Brasil: desigualdades regionais e prevalência segundo características ocupacionais Tobacco smoking in Brazil: regional inequalities and prevalence according to occupational characteristics

    Directory of Open Access Journals (Sweden)

    Aluísio J. D. Barros

    2011-09-01

    Full Text Available O estudo descreveu a prevalência do tabagismo diário segundo sexo, idade, renda domiciliar e ocupação dos moradores de 15 anos ou mais, no Brasil e regiões, baseado nos dados da Pesquisa Nacional por Amostra Domiciliar 2008 (PNAD/IBGE. A análise considerou o desenho da amostra e incluiu 252.768 indivíduos. A prevalência de fumo diário no Brasil foi 15,1%, variando de 12,8% na região Norte a 17,4% na região Sul, sendo 62% maior nos homens que mulheres. A prevalência de fumo foi inversamente proporcional à renda domiciliar, sendo 18,6% entre os 20% mais pobres e 11,5% entre os 20% mais ricos. As mesmas tendências para sexo, idade e renda foram observadas nas diferentes regiões do país. O consumo diário de cigarros foi 3% maior entre os trabalhadores comparados com não trabalhadores. Trabalhadores não manuais apresentaram prevalências de fumo abaixo de 10%, enquanto trabalhadores manuais relataram frequências acima de 20%. A associação entre tabagismo e ocupação permaneceu após ajuste para sexo, idade e renda. As desigualdades encontradas devem ser consideradas no planejamento e direcionamento de ações efetivas para redução do tabagismo. Os grupos ocupacionais mais expostos deveriam ter prioridade nas intervenções.This study describes the prevalence of daily tobacco smoking according to sex, age, per capita household income and occupation of residents aged 15 years or more in Brazil and regions using data from the 2008 National Household Sample Survey (PNAD/IBGE. The analysis was adjusted for the sampling design and included 252.768 individuals. Daily smoking prevalence in Brazil was 15.1%, varying from 12.8% in the North region to 17.4% in the South region, and it was 62% higher in men compared to women. Smoking prevalence was inversely proportional to household income, 18.6% among the poorest 20% and 11.5% among the wealthiest 20%. The same trends for gender, age and income were observed in the different regions of

  11. Administração de medicamentos injetáveis por via intramuscular: conhecimento dos ocupacionais de farmácias Administration of intramuscular injections medications: knowledge of occupationals working in pharmacies

    Directory of Open Access Journals (Sweden)

    Silvia Mara Rangel

    2000-06-01

    Full Text Available Complicações advindas da aplicação incorreta das injeções intramusculares podem acarretar sérios prejuízos orgânicos, favorecer o aparecimento de infecções e aumentar a permanência do paciente na instituição ou prejudicar as funções no trabalho. Estudo anterior detectou vários casos de pacientes com complicações locais após aplicação intramuscular de diclofenaco sódico em farmácias e concluiu que a falta de conhecimento da técnica de administração desse medicamento pode ter sido uma das causas das complicações. Diante disso o estudo atual teve o objetivo de identificar e avaliar o nível de conhecimentos de ocupacionais que administram medicamentos injetáveis intramusculares à população, em farmácias de Ribeirão Preto - SP. O estudo se constituiu num levantamento, a partir de um questionário contendo 20 questões abertas e fechadas, aplicado a uma população constituída por ocupacionais atuando em farmácias, selecionadas através do método da amostragem simples casual estratificada -partilha proporcional, resultando num total de 41 sujeitos. Concluímos que a população vem recebendo medicamento s injetáveis de ocupacionais com déficit de informações a respeito da técnica de aplicação de injetáveis. Os sujeitos referiram não receber treinamento adequado para exercer esse procedimento, terminando por aprendê-lo com outro funcionário ou observando alguém que o realize. Disto resulta lacunas de conhecimento em uma amostra de ocupacionais que podem, realmente, levar ao aparecimento de complicações pós injeções intramusculares na população que utiliza os serviços desses estabelecimentos.Complications from the incorrect administration of intramuscular injections can cause serious organic damages, infections and increase the patient's permanence in health institution or to harm the functions in the work. The previous study detected several cases of patients with local complications after

  12. O INSTITUTO DO INQUÉRITO CIVIL VISTO COMO FORMA E MEIO IMPORTANTE PARA PACIFICAR AS DEMANDAS COLETIVAS E A DISCUSSÃO DE SEU DEVIDO PROCESSO CONSTITUCIONAL

    Directory of Open Access Journals (Sweden)

    Francisco das Chagas da Silva

    2017-06-01

    Full Text Available O objetivo deste trabalho é abordar as peculiaridades do inquérito civil no direito brasileiro sob a ótica dos princípios que embasam o devido processo legal. Introduzido pela lei da Ação Civil Pública, o Inquérito Civil é um instituto de titularidade do Ministério Público voltado a auxiliar a pacificação dos conflitos coletivos, servindo de fundamento para a propositura de ações coletivas e de firmação do termo de ajustamento de conduta (TAC, mecanismos processuais e extraprocessuais que tem como finalidade a defesa de interesses difusos, coletivos e individuais homogêneos. Durante todo o desenvolvimento desta pesquisa foram analisadas diversas obras literárias dos mais variados autores da área do direito processual civil, do direito processual do trabalho e do direito constitucional, além da apreciação de dados oriundos da jurisprudência pátria, bem como revistas e periódicos da área jurídica pertinentes ao tema aqui desenvolvido. O trabalho está dividido numa apreciação sobre o devido processo constitucional e nos princípios norteadores do processo. Depois será desenvolvida uma análise acerca da natureza jurídica do inquérito civil e, por fim, uma discussão acerca do contraditório nesse procedimento administrativo, verificando as argumentações doutrinárias que negam a aplicação deste princípio.

  13. Atitude frente à dor em trabalhadores de atividades ocupacionais distintas: uma aproximação da psicologia cognitivo-comportamental Attitude of workers with chronic pain in different occupational activities: an approach of the cognitive-behaviorist psychology

    Directory of Open Access Journals (Sweden)

    Mônica A. G. de Lima

    2005-03-01

    Full Text Available Este estudo apresenta o perfil da atitude frente à dor em trabalhadores inseridos em atividades ocupacionais distintas com diagnóstico de LER/DORT acompanhados pelo Centro de Estudos da Saúde do Trabalhador do Estado da Bahia (CESAT/Ba. Foram entrevistados 65 trabalhadores numa amostra de conveniência. Utilizou-se como instrumento o Inventário de Atitudes Frente à Dor, na versão reduzida IAD, adaptado para língua portuguesa, contando com sete domínios ou escalas: cura médica, controle, solicitude, incapacidade, medicação, emoção e dano físico. Na análise procedeu-se a comparação das médias das escalas do IAD-breve entre as atividades ocupacionais e as variáveis socioculturais. A comparação das escalas entre as atividades ocupacionais, sexo e limitação para o trabalho revela diferenças entre as médias do domínio dano físico numa direção mais desfavorável para os industriários, sexo masculino e menor limitação para o trabalho e nos domínios emoção e controle mais favorável entre os praticantes de religião. Esses achados apontam para a possibilidade de utilização dessa abordagem para uma melhor compreensão da complexidade do fenômeno da dor crônica, assim como a necessidade de expandir o conceito da assistência e reabilitação desses trabalhadores tendo como referência um modelo de cuidado integral.This study presents the attitude of workers in different activities (bank workers, checkout workers and industrial workers with chronic pain related to the Repetition Strain Injures (RSI diagnosed in an occupational outpatient clinic - Centro de Estudos da Saúde do Trabalhador (CESAT, in the State of Bahia, Brazil. Sixty five workers from a convenience sample were interviewed, using the short version of the Survey of Pain Attitude, adapted to the Portuguese language. This questionnaire contains seven domains: control, emotion, disability, physical impairment, medication, solicitude, medical cure. Student

  14. Profissionais de saúde mental: estresse e estressores ocupacionais stress e estressores ocupacionais em saúde mental Profesionales de la salud mental: estrés y estresores ocupacionalesestrés y estresores ocupacionales en salud mental Mental health professionals: stress and occupational stressors stress and occupational stressors of mental health

    Directory of Open Access Journals (Sweden)

    Ana Flávia de Oliveira Santos

    2010-06-01

    Full Text Available Os profissionais de saúde mental se encontram particularmente vulneráveis ao estresse, em vista das características do trabalho que desempenham. O objetivo do estudo foi avaliar manifestações de estresse, autopercepção de estresse e fatores estressantes do trabalho em profissionais de serviços substitutivos de saúde mental. Participaram 25 trabalhadores com pelo menos seis meses de atuação profissional. Aplicaram-se os instrumentos Inventário de Sintomas de Estresse para Adultos de Lipp e Roteiro Complementar. Os dados quantitativos foram tratados por meio de estatística descritiva, e os demais, analisados qualitativamente. Verificou-se que 36,0% dos profissionais apresentavam manifestação de estresse e que 44,0% deles se percebiam sob estresse. Condições de trabalho e relacionamento no trabalho foram os fatores mais frequentemente associados à percepção de estar sob estresse. Concluiu-se que os profissionais vivenciam estressores associados às mudanças relativas ao paradigma psicossocial de atenção, o que mostra a necessidade de intervenção direcionada ao desenvolvimento de estratégias de enfrentamento às situações ocupacionais estressoras.Los profesionales de la salud mental se encuentran particularmente vulnerables al estrés, teniendo en vista las características del trabajo que desempeñan. El objetivo del estudio fue evaluar manifestación de estrés, auto percepción de estrés y factores estresantes del trabajo en profesionales de servicios sustitutivos de salud mental. Participaron 25 trabajadores actuantes hace por lo menos seis meses. Se aplicaron los instrumentos Inventario de Síntomas de Estrés para Adultos de Lipp y Guión Complementario. Los datos cuantitativos fueron tratados por medio de estadística descriptiva y los demás, analizados cualitativamente. Se verificaron 36,0% de los profesionales con manifestación de estrés y 44,0% percibiéndose bajo estrés. Condiciones de trabajo y relaci

  15. Poluentes do ar e internações devido a doenças cardiovasculares em São José do Rio Preto, Brasil

    Directory of Open Access Journals (Sweden)

    Kátia Cristina Cota Mantovani

    2016-02-01

    Full Text Available Resumo O presente estudo teve como objetivo estimar os efeitos de poluentes ambientais sobre o número de internações por doenças cardiovasculares. Foi um estudo ecológico com dados de internações hospitalares de residentes em São José do Rio Preto, São Paulo, Brasil, com diagnóstico nas categorias de I-00 a I-99, entre 01/10/11 e 30/09/12. Os poluentes analisados foram partículas finas (PM2,5, ozônio, monóxido de carbono, óxido de nitrogênio e dióxido de nitrogênio. Foram estimados pelo modelo CCATT-BRAMS. O uso do modelo aditivo de regressão de Poisson foi utilizado para estimar associação entre a exposição ao PM2,5 e internação por doença cardiovascular. Foram calculados os excessos de internação e os gastos por estas doenças. Observou-se que a exposição ao PM2,5 no quinto dia após a exposição (lag 5 foi significativo para internação e aumentou em 15 ppts segundo incremento de 10µg /m3 na concentração de PM2,5. Foram identificadas 650 internações evitáveis com custos da ordem de R$ 1,9 milhão. Desse modo, foi possível identificar associação entre exposição ao PM2,5 e internações devido a doenças cardiovasculares em cidades de médio porte como São José do Rio Preto fornecendo subsídios aos gestores municipal e regional de Saúde.

  16. Internamento devido a PAC por Streptococcus pneumoniae - Avaliação de factores de mortalidade Streptococcus pneumoniae - caused CAP in hospitalised patients: mortality predictors

    Directory of Open Access Journals (Sweden)

    Sandra Figueiredo

    2008-10-01

    Full Text Available A avaliação da gravidade perante qualquer caso de pneumonia adquirida na comunidade (PAC é de suma importância, pois dela decorrem decisões como a necessidade de internamento e o tratamento empírico inicial. Os autores apresentam um estudo retrospectivo, que incluiu doentes internados devido a pneumonia por Streptococcus pneumoniae durante o ano de 2006, no Hospital de São João. A confirmação etiológica de infecção foi feita por isolamentos no sangue, líquido pleural, secreções traqueobrônquicas, lavado brônquico, lavado broncoalveolar e pesquisa de antigenúria. Foram analisados os factores de risco e avaliados, com base nas normas PSI (Pneumonia Severity Index e da British Thoracic Society (BTS - CURB-65. A análise estatística foi efectuada utilizando teste T para amostras independentes e ANOVA, usando o programa de análise estatística SPSS 14.0. Foram incluídos 104 doentes com idade mediana de 63 anos, sendo 67,3% do sexo masculino. O estudo revelou existir uma associação com significado estatístico entre os resultados de PSI e CURB-65 e a evolução para a mortalidade. Apesar da melhoria dos meios diagnósticos e profilácticos, e da terapêutica antibiótica, a pneumonia pneumocócica permanece uma entidade de grande morbilidade e mortalidade. O valor preditivo das normas PSI e CURB-65 foi confirmado nesta população de doentes, documentando uma correlação entre o número de factores de risco e a evolução da doença.Probably the most important decision in the management of Community-Acquired Pneumonia (CAP is patient site of care. Patients with Streptococcus pneumoniae-caused CAP admitted to our hospital between 1st January and 31st December 2006 were retrospectively analysed. Samples of blood, sputum, bronchial and bronchoalveolar lavage and urine were collected for microbiological testing using standard culture techniques and urine antigen detection. Pneumonia Severity Index (PSI and British Thoracic Society

  17. Riscos ocupacionais na legislação trabalhista brasileira: destaque para aqueles relativos à saúde e à voz do professor Occupational risks in the Brazilian labor legislation: highlight on those related to teacher's health and voice

    Directory of Open Access Journals (Sweden)

    Emilse Aparecida Merlin Servilha

    2010-12-01

    Full Text Available OBJETIVO: Analisar a legislação a respeito de riscos ocupacionais, com destaque para aqueles relacionados à saúde e à voz do professor. MÉTODOS: Trata-se de pesquisa bibliográfica, de caráter qualitativo, que considerou as políticas públicas sobre Saúde e Segurança no Trabalho. As Normas Regulamentadoras foram lidas e seus conteúdos analisados e organizados por categorias, com recorte para aqueles referentes ao ambiente escolar. RESULTADOS: As 33 normas focalizam os fatores de risco, níveis de tolerância e controle para saúde e segurança no trabalho. Os agentes ambientais nocivos são múltiplos e suas especificidades, como concentração e frequência, determinam o nível de tolerância à exposição. Na escola, os riscos ambientais como ruído, poeira, temperatura e iluminação inadequadas, dentre outros, estão presentes, porém em grau leve. O tratamento acústico, de iluminação e de ventilação é indicado para controle desses riscos. Os documentos mostram situações de agravos à saúde dos trabalhadores em graus de risco muito maiores do que aqueles da docência. Não há explicitação de fatores inerentes à organização do trabalho e os cuidados com a voz limitam-se à profissão de teleoperador, o que pode servir de referência para o professor. CONCLUSÃO: A legislação trabalhista é ampla ao abarcar a diversidade de condições de trabalho e garantir a saúde dos trabalhadores. A docência apresenta riscos ocupacionais à saúde mais leves do que outras profissões; contudo, os fatores organizacionais do trabalho, assim como os distúrbios de voz, muito frequentes na docência, carecem de maior atenção da legislação no Brasil.PURPOSE: To analyze the legislation regarding occupational risks, highlighting those related to teacher's health and voice. METHODS: A bibliographic search of qualitative nature regarding the public policies about Health and Security at Work was carried out. The Regulatory

  18. Chemical occupational risks identified by nurses in a hospital environment Riesgos ocupacionales químicos identificados por enfermeros que trabajan en ambiente hospitalario Riscos ocupacionais químicos identificados por enfermeiros que trabalham em ambiente hospitalar

    Directory of Open Access Journals (Sweden)

    Rosicler Xelegati

    2006-04-01

    mayor conocimiento respecto a los riesgos ocupacionales químicos, que podrían haber recibido en el pregrado o en los cursos de educación continuada.Os trabalhadores de enfermagem hospitalares submetem-se aos riscos ocupacionais químicos. Este estudo quantitativo objetivou identificar entre enfermeiros com quais substâncias químicas eles têm contato ocupacional, quais as que podem causar problemas à sua saúde e que alterações condizem com as que podem ser ocasionadas por produtos químicos. Um instrumento de coleta de dados auto-administrado foi respondido por 53 enfermeiros que mencionaram estar expostos principalmente aos antibióticos e benzina (100%, iodo (98,1% e látex-talco (88,7%; as principais substâncias causadoras de problemas de saúde citadas foram antineoplásicos (86,7%, glutaraldeído (79,2% e óxido de etileno (75,5%; as alterações à saúde que descreveram foram: lacrimejamento; reações alérgicas; náuseas e vômitos, não mencionando outros problemas de saúde que podem ser ocasionados pelos produtos citados. Estes trabalhadores necessitam adquirir maior conhecimento quanto aos riscos ocupacionais químicos, que poderiam ter recebido na graduação / ou nos cursos de educação continuada.

  19. Contexto da atenção à saúde mental: percepção de terapeutas ocupacionais sobre a avaliação / Context of mental health care: perceptions of occupational therapists about the evaluation

    Directory of Open Access Journals (Sweden)

    Mariana Felício de Godoy

    2017-11-01

    Full Text Available A avaliação constitui etapa essencial no processo terapêutico ocupacional, entretanto, a produção de conhecimento sobre esta temática no cenário nacional é ainda escassa. Este trabalho tem por objetivo analisar a percepção de terapeutas ocupacionais sobre os processos de avaliação que realizam nos serviços que atuam na atenção à saúde mental de um município do interior de São Paulo, Brasil. Trata-se de um estudo exploratório, descritivo e de natureza qualitativa. Para tanto, foram analisados relatos pertinentes ao material coletado em campo, resultante da realização de 14 entrevistas semiestruturadas com os terapeutas ocupacionais, assim como a aplicação de questionário contendo perguntas abertas e fechadas. Os resultados obtidos evidenciaram que os terapeutas ocupacionais eram prioritariamente do sexo feminino, com média idade de 35 anos. Atuavam em diferentes serviços da Rede de Atenção Psicossocial do município - Centros de Atenção Psicossocial tipo, III, álcool e outras drogas, Serviço de Geração de Renda e Enfermaria de Psiquiatria em Hospital Geral. Constatou-se que os profissionais utilizavam diversas estratégias avaliativas, embora não utilizassem instrumentos padronizados e validados específicos da Terapia Ocupacional. Os entrevistados referiram avaliar os usuários em diferentes momentos (triagem, acolhimento e ao longo do processo de acompanhamento e ressaltaram a importância da avaliação em outros contextos, no caso, o domicílio. As principais demandas dos usuários identificadas nos processos avaliativos relacionavam-se às dificuldades de realização nas atividades cotidianas. A análise dos resultados obtidos evidenciou a necessidade de que outros estudos possam ser desenvolvidos contribuindo assim para o oferecimento de um cuidado cada vez mais qualificado.Abstract The evaluation is an essential step in the occupational therapeutic process, however, the production of knowledge about

  20. Nasal septum resection due congenital thickness in foalsRessecção de septo nasal devido ao espessamento congênito em potros

    Directory of Open Access Journals (Sweden)

    Antônio Felipe Paulino de Figueiredo Wouk

    2012-04-01

    ão foi possível introduzir o equipamento na cavidade nasal devido à estenose bilateral. O exame radiográfico confirmou o aumento na espessura do septo nasal. Os animais foram submetidos à cirurgia de ressecção de septo. Para promover uma melhor condição respiratória a traqueostomia foi realizada nos dois potros antes da cirurgia. A técnica cirúrgica utilizada foi modificado da técnica descrita anteriormente DOYLE (2005. Inicialmente foi realizada a trepanação do osso nasal para osteotomia da porção caudal do septo, com auxilio de osteótomo modificado, sendo os limites dorsais e ventrais do septo removidos com uso de fio serra protegido por guias metálicos. Após a recuperação cirúrgica, nos dois casos, o exame clínico mostrou que o fluxo de ar estava normal e sem ruídos permitindo aos potros respirar normalmente. A traqueostomia cicatrizou por segunda intenção. Após oito meses os dois animais respiravam confortavelmente, estando aptos à atividade física. O exame histopatológico não demonstrou sinais de inflamação, neoplasia ou outro tipo de alteração histológica relacionada aos septos, sugerindo espessamento congênito.

  1. Modelo operário e percepção de riscos ocupacionais e ambientais: o uso exemplar de estudo descritivo The "worker model" and perception of environmental and occupational risks: the optimal use of a descriptive study

    Directory of Open Access Journals (Sweden)

    Luiz A. Facchini

    1991-10-01

    Full Text Available Objetivou-se identificar os riscos resultantes da exposição a produtos químicos, de trabalhadores de indústria química e farmacêutica. Realizou-se estudo descritivo, através do modelo operário (MO, onde o acesso aos trabalhadores significava uma parte essencial do método e a única forma de neutralizar a impossibilidade de acesso ao local de trabalho. Reconstruíam-se as atividades dos setores de trabalho e identificaram-se as principais substâncias químicas utilizadas, as queixas mais referidas, os danos potenciais e os principais riscos ambientais, concluindo pela precariedade das condições gerais de trabalho. Com os resultados confirmados, ficou evidenciada a importância do MO e sua utilidade metodológica, levando trabalhadores a conseguir das autoridades que a empresa fosse vistoriada. A mobilização dos trabalhadores, através de denúncias nos meios de comunicação, ajudou a formar uma consciência popular dos riscos ocupacionais e ambientais daquela atividade produtiva.An attempt was made to identify the risks resulting from exposure to the chemicals to which workers are exposed as well as from the poor working conditions to which they are subject in a chemical and pharmaceutical factory. A descriptive study based on the "workers model" - a methodological approach developed in Italy in the 60's, was carried out. Such a study requires direct contact with the workers and has the advantage of overcoming the difficulty of gaining access to their work-place. The activities of the different departments of the plant were reconstructed and the main chemicals used, the main physical complaints, the potencial harms and the main environmental risks identified. The repon on the harmful working conditions produced was used by the workers as a means of pressing the authorities into carrying out an inspection of the plant concerned to verify its accuracy. The report's findings have been confirmed and demonstrate the usefulness of the

  2. Execução especial por alimentos devidos a menores e execução de decisões em matéria de obrigações alimentares nas relações transfronteiriças

    OpenAIRE

    Faria, Soraia Carvalho

    2017-01-01

    Este trabalho versa sobre a obrigação de alimentos, especialmente sobre a execução de alimentos devidos a menores e sobre a cobrança transfronteiriça de obrigações alimentares. Começamos por definir o conceito de alimentos, que no caso de alimentos devidos a menores tem um âmbito mais amplo do que o conceito geral, tendo em conta as limitações do sujeito passivo, como incapaz aos olhos do Direito. Segundo as normas legais, os alimentos devidos a menores englobam não só tudo o que é indispensá...

  3. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  4. Riscos ocupacionais entre trabalhadores de enfermagem de uma unidade de terapia intensiva Riesgos ocupacionales entre trabajadores de enfermeria de una unidad de cuidados intensivos Occupational risks among a nursing staff working in an intensive care unit

    Directory of Open Access Journals (Sweden)

    Vera Médice Nishide

    2004-12-01

    Full Text Available Estudo descritivo no qual foram identificados os principais riscos ocupacionais a que estão expostos os trabalhadores de enfermagem de uma unidade de terapia intensiva. Os dados foram coletados por meio de entrevista individual, utilizando-se roteiro estruturado. Constatou-se que os trabalhadores estão expostos a riscos de acidentes relacionados aos procedimentos de assistência aos pacientes e ao ambiente laboral. Foi observado que a maioria dos trabalhadores utilizavam luvas, máscaras e aventais como barreiras de proteção, e um baixo percentual, óculos de sobrepor como medida de segurança. Concluiu-se que são necessárias mudanças no ambiente de trabalho para minimizar os riscos em procedimentos de assistência e no ambiente laboral, além de treinamento, conscientização de práticas seguras e fornecimento de dispositivos de segurança aos trabalhadores.Estudio descriptivo en el cual fueron identificados los principales riesgos ocupacionales a los que están expuestos los trabajadores de enfermería de una unidad de cuidados intensivos. Los datos fueron recolectados por medio de una entrevista individual, utilizándose un esquema estructurado. Se constató que los trabajadores están expuestos a riesgos de accidentes relacionados a los procedimientos de asistencia a los pacientes y al ambiente laboral. Fue observado que la mayoría de los trabajadores usaban guantes, máscaras y delantales como barreras de protección y un bajo porcentaje usaban anteojos de protección como medida de seguridad. El estudio dejó como conclusión la necesidad de modificaciones en el ambiente de trabajo para minimizar los riesgos en procedimientos de asistencia y del ambiente laboral, aparte del entrenamiento, concientización de prácticas seguras y ofrecimiento de dispositivos de seguridad a los trabajadores.This is a descriptive study that detected the main occupational risks to which the nursing staff working in an intensive care unit are exposed

  5. Prevalência de exposições ocupacionais de cirurgiões-dentistas e auxiliares de consultório dentário a material biológico Prevalence of occupational exposures to potentially infectious materials among dentists and dental assistants

    Directory of Open Access Journals (Sweden)

    Leila Posenato Garcia

    2006-01-01

    Full Text Available Os cirurgiões-dentistas e auxiliares de consultório dentário trabalham em condições que favorecem a ocorrência de exposições ocupacionais a material biológico. Os objetivos do presente estudo são: determinar a prevalência de exposições ocupacionais ao longo da vida profissional e no ano anterior a este estudo, identificar as circunstâncias das exposições e verificar se existe relação entre sua ocorrência e o uso de equipamentos de proteção individual. Participaram do estudo 289 dentistas e 104 auxiliares do município de Florianópolis, Santa Catarina, Brasil. Os dados foram coletados por meio de questionário auto-aplicável. A prevalência de exposições ocupacionais na vida profissional foi maior entre os dentistas (94,5% do que entre os auxiliares (80,8%, ao passo que, no ano anterior, foi similar entre dentistas (39,1% e auxiliares (39,4%. Todavia, considerando as exposições ocorridas no ano anterior, as lesões percutâneas foram mais freqüentes nos auxiliares (95,2% do que nos dentistas (60,7%. O uso constante de óculos de proteção foi estatisticamente associado com menor ocorrência de respingos nos olhos de dentistas (p = 0,004. São recomendadas medidas educativas visando a reduzir a freqüência de exposições ocupacionais na população estudada.Dentists and dental assistants work in conditions that favor the occurrence of occupational exposures to potentially infectious materials. The aims of this study are: to determine the prevalence of occupational exposures throughout professional life and in the previous year, to identify the circumstances of exposures, and to verify if there exists a relationship between their occurrence and the use of personal protective equipment. 289 dentists and 104 dental assistants from the city of Florianópolis, Brazil, participated in this study. Data were collected through self-report questionnaires. The prevalence of occupational exposures throughout professional life

  6. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  7. Analise da correlação entre o tono muscular, força muscular e as funções motoras em crianças com paralisia cerebral tetraparetica espastica devido a lesões hipoxico- isquemicas

    OpenAIRE

    Cristina Iwabe

    2003-01-01

    Resumo: A paralisia cerebral (PC) é um quadro clínico geralmente conseqüente à agressão não progressiva do cérebro em desenvolvimento, caracterizando-se por alterações do tono, força muscular e função motora. O objetivo deste estudo foi analisar a interferência do tono e força muscular nas funções motoras em crianças com paralisia cerebral tetraparética (pC-T) espástica devido a lesões hipóxico-isquêmicas (LHI). Foram avaliadas 15 crianças com diagnóstico de PC-T espástica na faixa etária de ...

  8. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  9. Riscos ocupacionais para trabalhadores de Unidades Básicas de Saúde: revisão bibliográfica Riesgos ocupacionales para trabajadores de Unidades Básicas de Salud: revisión bibliográfica Occupational risks for public health workers in Brazil: a systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Mônica Bonagamba Chiodi

    2006-06-01

    Full Text Available Este estudo teve como objetivo buscar evidências científicas na literatura nacional sobre os riscos ocupacionais a que estão expostos os trabalhadores que atuam na Saúde Pública. Estudo bibliográfico efetuado nos últimos 15 anos na base de dados LILACS, DEDALUS e Banco de Teses da Universidade de São Paulo. Foram encontradas 279 publicações enfocando os riscos ocupacionais, sendo que apenas 12 (4,3% abordaram os riscos ocupacionais em Saúde Pública, os quais eram voltados a Unidades Básicas de Saúde, Unidades Básicas e Distritais de Saúde e Núcleos de Saúde da Família. Os resultados permitiram constatar que os riscos psicossociais foram evidenciados em todas as pesquisas, seguido pelo risco biológico (66,7%. O tema merece maior atenção dos pesquisadores para o diagnóstico da situação laboral e para a formulação de medidas preventivas para a promoção da saúde desses trabalhadores.En este estudio se tuvo como objetivo buscar evidencias científicas en la literatura nacional sobre los riesgos ocupacionales a los que están expuestos los trabajadores que actúan en la Salud Pública. Se trata de un estudio bibliográfico efectuado en la base de datos LILACS, DEDALUS y Banco de Tesis de la Universidad de Sao Paulo, de los últimos 15 años. Se encontraron 279 publicaciones que enfocaban los riesgos ocupacionales, de las cuales apenas 12 (4,3% abordaban los riesgos ocupacionales en Salud Pública, voltados a Unidades Básicas de Salud, Unidades Básicas y Distritales de Salud y Núcleos de Salud de la Familia. Los resultados permitieron constatar que los riesgos psicosociales fueron evidenciados en todas las investigaciones, seguido por el riesgo biológico (66,7%. El tema merece mayor atención de los investigadores para el diagnóstico de la situación laboral y la formulación de medidas preventivas para la promoción de la salud de esos trabajadores.To determine scientific evidence in the Brazilian literature about

  10. Riscos ocupacionais em um setor de hemodiálise na perspectiva dos trabalhadores da equipe de enfermagem Riesgos ocupacionales en una unidad de hemodialisis en el perspectiva de los trabajadores del equipo de enfermería Occupational risks in a unit of hemodialysis in the perspective of the workers of the nursing team

    Directory of Open Access Journals (Sweden)

    Michele Karla Damacena da Silva

    2009-06-01

    Full Text Available Estudo descritivo exploratório, de abordagem qualitativa, teve como objetivos descrever os riscos ocupacionais no contexto dos trabalhadores da equipe de enfermagem em uma unidade de hemodiálise, analisar o conhecimento do trabalhador da equipe de enfermagem acerca das medidas de proteção e segurança em uma unidade de hemodiálise e discutir o conhecimento do trabalhador da equipe de enfermagem sobre os riscos ocupacionais e as implicações para a saúde do trabalhador. O cenário foi um hospital universitário do município do Rio de Janeiro. Os sujeitos foram 26 trabalhadores da equipe de enfermagem do setor de hemodiálise. Foi utilizada entrevista semiestruturada. O projeto foi aprovado por Comitê de Ética. Resultados: os trabalhadores detêm o conhecimento sobre os riscos ocupacionais e sobre as medidas de proteção e segurança, apesar de nem sempre aplicá-las na sua prática profissional. Foram citados como as principais implicações à saúde os problemas respiratórios, de coluna e as doenças contagiosas.Estudio descriptivo exploratorio, de abordaje cualitativo, que tenía como objetivo describir los riesgos ocupacionales en el contexto de los trabajadores del equipo de enfermería en una unidad de hemodialisis, analizar el conocimiento del trabajador del equipo de enfermería a respecto de las medidas de protección y seguridad en una unidad de hemodialisis y discutir el conocimiento del trabajador del equipo de enfermería sobre los riesgos ocupacionales y las implicaciones para la salud del trabajador. El escenario fue un Hospital Universitario de la ciudad de Rio de Janeiro (Brasil. Los sujetos fueron 26 trabajadores del equipo de enfermería del sector de hemodialisis. Fue utilizada la entrevista semi-estructurada. El proyecto fue aprobado por el Comité de Ética. Resultados: los trabajadores retienen el conocimiento sobre los riesgos ocupacionales y sobre las medidas de protección y seguridad, aunque ni siempre

  11. Associação de variáveis meteorológicas com os afastamentos do trabalho devido a doenças respiratórias: um estudo entre trabalhadores dos correios de Santa Catarina

    Directory of Open Access Journals (Sweden)

    Daniel Pires Bitencourt

    Full Text Available INTRODUÇÃO: As doenças do aparelho respiratório (DAR em trabalhadores são, com frequência, atribuídas ao ambiente de trabalho ou ao tipo de atividade. Poucos estudos relacionam as DAR com as condições de tempo. OBJETIVO: Este artigo tem como objetivo identificar a existência desta relação através da comparação da taxa de afastamento do trabalho com as médias mensais de variáveis meteorológicas. MÉTODOS: Para tanto, calculou-se a correlação dos afastamentos com as médias mensais de temperatura e umidade, com os valores mínimos mensais de temperatura e umidade e com a maior queda de temperatura em 24h ocorrida no mês. A série de dados meteorológicos com melhor correlação foi dividida em quartis (25% para identificar os valores típicos de afastamento em situações extremas de temperatura ou umidade. Os afatamentos por DAR foram calculados em trabalhadores dos Correios de Santa Catarina e os dados meteorológicos foram obtidos da reanálise de modelos numéricos. O período analisado compreendeu janeiro de 2001 a dezembro de 2007, totalizando 84 meses. RESULTADOS: Os afastamentos do trabalho devido às DAR obtiveram melhor associação, em ordem de importância, com a temperatura média do mês, a temperatura mínima do mês e o maior declínio de temperatura do mês. Todas essas correlações obtiveram significância estatística de 0,1%. A umidade do ar não demonstrou associação com a taxa de afastamento. CONCLUSÃO: Conclui-se que as maiores taxas de afastamento do trabalho devido às DAR ocorrem nos meses mais frios e secos.

  12. Clinical and pathological aspects of multicentric hemangiosarcoma in a Pinscher dog Sinais neurológicos multifocais devido ao hemangiossarcoma multicêntrico em um cão Pinscher: aspectos clínicos e patológicos

    Directory of Open Access Journals (Sweden)

    B.D.C. Martins

    2013-04-01

    Full Text Available A 3-year-old female Pinscher dog was presented with a history of lameness and pain in hind limbs for one week which acutely progressed to non-ambulatory paraparesis. The dog had been apathetic and anorexic during the six days prior to presentation. The neurological findings were compatible with upper motor neuron signs to the left hind limb due to a spinal cord compressive mass on the twelfth thoracic vertebral body. On the other hand, signs of lower motor neurons to the right hind limb were due to a mass with a pathological fracture in the right proximal femur, compressing the sciatic nerve. A histopathological analysis of all organs revealedthe proliferation of endothelial cells showingin filtrative growth and organization into vascular structures with a solid pattern. In addition, immunohistochemycal analysis revealed low proliferation index and citoplasmatic positivity for CD-31, confirming the vascular nature of the neoplasm. Clinical, histopathological and immunophenotipical findings were consistent with hemangiosarcoma.Uma cadela Pinscher de três anos de idade foi atendida em Hospital Veterinário Escola com histórico de dor nos membros pélvicos com progressão aguda para paraparesia não ambulatória. O animal estava apático e anoréxico há seis dias. Os achados neurológicos foram compatíveis com sinais de lesão de neurônios motores superiores para o membro pélvico esquerdo devido a uma massa no 12º corpo vertebral comprimindo a medula espinhal. Por outro lado, foram observados sinais de lesão de neurônios motores inferiores para o membro pélvico direito devido a uma fratura patológica no colo proximal do fêmur direito que comprimiu o nervo isquiático. Análises histopatológicas de todos os órgãos revelaram proliferação de células endoteliais com crescimento infiltrativo e organização sólida em estruturas vasculares. Adicionalmente, a análise imuno-histoquímica revelou baixa proliferação e marca

  13. Mortalidade por cirrose, câncer hepático e transtornos devidos ao uso de álcool: Carga Global de Doenças no Brasil, 1990 e 2015

    Directory of Open Access Journals (Sweden)

    Ana Paula Souto Melo

    Full Text Available RESUMO: Introdução: O uso de álcool é um dos principais fatores de risco preveníveis para mortalidade ou incapacidade prematuras. Objetivo: Descrever as estimativas de mortalidade e anos de vida perdidos por morte prematura (YLL por cirrose, câncer hepático e transtornos devidos ao uso de álcool no Brasil e suas unidades da federação (UFs, em 1990 e 2015. Métodos: Estudo descritivo com dados do estudo de Carga Global de Doenças (2015 e do Sistema de Informações sobre Mortalidade (SIM. Modelos estatísticos foram empregados para obter estimativas corrigidas de mortalidade pelas causas selecionadas. As taxas de mortalidade foram padronizadas por idade (TMPI. Resultados: Em 1990, foram estimados 16.226 óbitos para as 3 condições (17,0/100 mil habitantes, enquanto em 2015 foram 28.337 (15,7/100 mil habitantes. Houve redução da mortalidade (por 100 mil habitantes por cirrose (de 11,4 para 9,5 e estabilidade por câncer hepático (1,5 e 1,9 e transtornos devidos ao uso de álcool (4,1 e 4,3. As TMPI foram 5,1 vezes maiores entre os homens, e as 5 UFs com maiores TMPI e YLL foram da Região Nordeste: Sergipe, Ceará, Pernambuco, Paraíba e Alagoas. As taxas de mortalidade e de YLL pelas três condições estudadas ascenderam no ranking das causas de óbito, em ambos os sexos, exceto a cirrose no feminino. Conclusão: As três condições estudadas são responsáveis por importante carga de mortalidade prematura no Brasil, principalmente entre homens e residentes na região nordeste. Esses resultados reforçam a necessidade de políticas públicas para o enfrentamento ao consumo nocivo do álcool no Brasil.

  14. Activities, procedures and doses in pediatric patients due to radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Silvia Maria Velasques de Oliveira

    2008-12-01

    Full Text Available An investigation performed between 2003 and 2005 in sixteen selected public and private institutions in Northeast, Southeast and South geographical regions of Brazil evaluated average organ doses and effective doses in 2,411 pediatric patients due to diagnostic procedures with radiopharmaceuticals. For 1 year, effective doses were greater than literature. For 5 years, differences were noticed between present work and literature for bone scintigraphy, thyroid scintigraphy and 67Ga citrate scintigraphy. These differences may be attributed to the uncertainties in internal dose calculations. High absorved doses in bone surfaces of children due to 67Ga citrate and bone scintigraphy should be evaluated accordingly. Current protocols used recommend standardized mean activities per mean weight for all ages. However, it was observed that the activities were not standardized and were higher for children with younger ages. Future studies are needed for optimising activities of radiopharmaceuticals to these patients in the country.Foi realizado no Brasil, no período 2003-2005, um estudo sobre doses absorvidas em órgãos e doses efetivas devido ao uso de radiofármacos em pacientes pediátricos. Foram estudadas 2.411 crianças e adolescentes menores de 18 anos. Foi observado que as atividades usadas não foram padronizadas, sendo maiores para crianças de menor idade, podendo ser otimizadas conforme apropriado. Para 1 ano, as doses efetivas foram maiores do que as publicadas na literatura e para 5 anos, foram observadas diferenças para cintilografias ósseas, cintilografias da tireóide, e pesquisas de corpo inteiro com citrato de 67G. Deve ser avaliado se doses absorvidas em órgãos, especialmente para superfície óssea devido a cintilografias ósseas com 99mTc MDP e pesquisa de corpo inteiro com citrato de 67Ga podem acarretar risco radiológico adicional aos pacientes, considerando-se as peculiaridades de seu estado clínico.

  15. Chemical treatment to unclogg dripper irrigation systems due to biological problems Desentupimento de um sistema de irrigação por gotejamento devido a problema de origem biológica

    Directory of Open Access Journals (Sweden)

    Túlio Assunção Pires Ribeiro

    2008-02-01

    Full Text Available Many producers use drippers for trickle irrigation systems for flower production in the field and in protected environments. A frequent problem in this type of irrigation system is the clogging of drippers, which is directly related to water quality and filtering system efficiency. The objective of this study was to conduct an experimental investigation to evaluate the efficiency of using nitric acid and sodium hypochlorite to unclogg drippers due to the use of water with high algae content. The evaluation was conducted in six, 4216 m² greenhouses, each with two sectors comprised of ten spaces or lines, totaling 12 sectors of a dripper irrigation system in a rose producing property of Holambra, State of SP, Brazil. Chemical and physical analyses and the bacteriological count in water were carried out in the three water sources that supply the irrigation system to check the factors causing the clogging. Evaluations were carried out on water distribution uniformity in all sectors before and after chemical treatment in order to evaluate efficiency. The treatment improved water distribution uniformity and a lead to a reduction in the coefficient of variation (CV for dripper flow in all sectors. There was a good correlation between CV and the water distribution uniformity index. Therefore, this is an excellent method to be used to unclogg drippers due to biological problems.Muitos produtores usam gotejadores para irrigação localizada em produção de flores no campo e em ambientes protegidos. Um problema freqüente neste tipo de irrigação é o entupimento dos gotejadores, que está diretamente relacionado à qualidade da água e à deficiência de filtração do sistema. Este trabalho teve como objetivo fazer uma investigação experimental para avaliar a eficiência da utilização de ácido nítrico e de hipoclorito de sódio na desobstrução de gotejadores entupidos, devido à utilização de águas com elevado teor de matéria de origem

  16. Pigmentary retinopathy due to Bardet-Biedl syndrome: case report and literature review Retinopatia pigmentar devido a síndrome de Bardet-Biedl: relato de caso e revisão da literatura

    Directory of Open Access Journals (Sweden)

    Luis Jesuino de Oliveira Andrade

    2009-10-01

    Full Text Available Bardet-Biedl syndrome (BBS is a rare autosomal recessive disorder with clinical and genetic heterogeneity. This syndrome was first described by Laurence and Moon in 1866 and additional cases were described by Bardet and Biedl between 1920 and 1922. The main features are obesity, polydactyly, pigmentary retinopathy, learning disabilities, various degrees of intellectual impairment, hypogonadism, and renal abnormalities. Bardet-Biedl syndrome is both phenotypically and genetically heterogeneous. Clinical diagnosis is based on the presence of 4 of the 5 cardinal features. The authors present a typical case of pigmentary retinopathy due to Bardet-Biedl syndrome and made a brief commentary about the disease's cardinal manifestations.A síndrome de Bardet-Biedl (BBS é uma desordem autossômica recessiva rara, com heterogeneidade clínica e genética. Esta síndrome foi descrita pela primeira vez por Laurence e Moon em 1866 e outros casos foram descritos por Bardet e Biedl entre 1920 e 1922. As principais características são obesidade, polidactilia, retinopatia pigmentar, dificuldades de aprendizagem, graus de deficiência intelectual diversos, hipogonadismo e anomalias renais. Síndrome de Bardet-Biedl é fenotipicamente e geneticamente heterogêneos. O diagnóstico clínico baseia-se na presença de quatro dos cinco sinais principais da síndrome. Os autores apresentam um caso típico de retinopatia pigmentar devido à síndrome de Bardet-Biedl e fazem uma breve revisão sobre as manifestações da síndrome com especial atenção à retinopatia pigmentar.

  17. Maternidade e hanseníase: as vivências de separação devido ao isolamento compulsório Being a mother with leprosy: the experiences of separation due to compulsory isolation

    Directory of Open Access Journals (Sweden)

    Suellen Santos Lima de Almeida

    2012-08-01

    Full Text Available As mulheres portadoras de hanseníase, durante grande parte do século XX, não puderam exercer a maternidade devido à política de isolamento compulsório dos doentes adotada para controlar a doença. Os filhos ao nascerem eram levados para os preventórios e o contato com estes era realizado pelo olhar. Visando compreender a experiência da maternidade no hospital colônia foi realizada pesquisa narrativa com três mães que viveram o período de internação compulsória. Os discursos revelam dois momentos distintos da vivência de maternidade: a separação dos filhos com sua posterior volta para casa e a adoção de crianças para realizar a maternidade. Considera-se que a adoção promoveu o encontro com o sentido da existência que havia sido rompido e possibilitou a experiência de ser-mãe.In the twentieth century, women with leprosy could not carry on their maternity because of the statement of compulsory isolation of patients, adopted to control the disease. Their children were taken at birth to prevention centers and the contact of mothers with their babies was only visual. In order to understand the experience of maternity in the leprosaria it was carried out an investigated narrative research with three mothers who lived through the period of compulsory internment. The speeches reveal two distinct moments in the experience of motherhood: the separation of the children with their subsequent return to home and the adoption of other children to achieve motherhood. It is considered that the adoption has promoted the meeting with the meaning of existence that had been broken and allowed the experience of being a parent.

  18. A produção científica sobre riscos ocupacionais a que estão expostos os trabalhadores de enfermagem La producción científica sobre riesgos ocupacionales a que están expuestos los trabajadores de enfermería The scientific production about occupational risks to which the nursing workers are exposed

    Directory of Open Access Journals (Sweden)

    Magda Ribeiro de Castro

    2008-06-01

    Full Text Available Estudo realizado no Curso de Mestrado na Escola de Enfermagem Anna Nery, inserido no Núcleo de Pesquisa em Enfermagem e Saúde do Trabalhador da Universidade Federal do Rio de Janeiro. Objeto: a produção científica sobre riscos ocupacionais a que estão expostos os trabalhadores de enfermagem. Objetivos: levantar a produção científica dos estudos stricto sensu acerca dos riscos ocupacionais nos trabalhadores de enfermagem; identificar a abordagem (objetiva ou subjetiva acerca desses riscos e analisar os riscos retratados. Estudo bibliográfico e quantitativo dos 42 resumos publicados no Centro de Estudos e Pesquisas em Enfermagem entre 1979 e 2004. Riscos mais expressivos: biológicos, seguidos dos químicos, dos psicossociais e, em menor escala, dos físicos, de acidentes e ergonômicos. Percebeu-se reduzida ênfase dispensada à subjetividade do trabalhador de enfermagem associada à temática estudada, sugerindo lacuna nesta área de conhecimento. Faz-se necessária a reflexão desses riscos na enfermagem, atentando para sua identificação, detecção e controle.Estudio realizado en el Curso de Maestría de la Escuela de Enfermería Anna Nery, inserto en el Núcleo de Investigación en Enfermería y Salud del Trabajador de la Universidad Federal de Río de Janeiro. Objeto: la producción científica sobre riesgos ocupacionales a que están expuestos los trabajadores de enfermería. Objetivos: hacer un búsqueda de la producción científica de los estudios stricto sensu acerca de los riesgos ocupacionales en los trabajadores de enfermería; identificar el abordaje (objetivo o subjetivo acerca de los riesgos y analizar los riesgos retratados. Estudio bibliográfico y cuantitativo de 42 resúmenes publicados en el Centro de Estudios e Investigación en Enfermería entre 1979 a 2004. Riesgos mas expresivos: biológicos, seguido de químicos, psicosociales y en menor escala, los físicos, accidentes y riesgos ergonómicos. Se percibi

  19. Orofacial clefts in the newborn and environmental and occupational parental exposures: a case-control study in Rio de Janeiro, Brazil Fendas orofaciais no recém-nascido e exposições ambientais e ocupacionais dos pais: um estudo caso-controle no Rio de Janeiro, Brasil

    Directory of Open Access Journals (Sweden)

    Isabel Cristina G Leite

    2003-12-01

    Full Text Available OBJECTIVES: to evaluate risk factors involving environmental and occupational parental exposures associated with occurrence of orofacial clefts in a group of Brazilian children. METHODS: a secondary base case-control study was conducted with 274 cases of cleft lip with or without cleft palate (CL±P and cleft palate only, with 548 controls (1:2. The authors analyzed residential proximity to industrial areas, exposure to commercial insecticides, agricultural pesticides, and vector control spraying, as well as various occupational exposures. The results were obtained by conditional regression analysis. RESULTS: proximity to industrial installations as a risk factor (OR = 3,32; 95%CI: 2,18-5,05 for all orofacial clefts, as well as the combined use of household insecticides and urban vector control pesticide spraying (OR = 5,73; 95%CI: 2,51-11,28. A group of maternal occupations heavily associated with orofacial clefts was domestic services (OR = 2,89; 95%CI: 1,76-4,86. CONCLUSIONS: solvents are frequently associated with CL ± P and that they are contained in numerous industrial products and household cleaning products, the results pertaining to occupational exposure become plausible. Other associations such as the routine use of domestic insecticides require further specific research for confirmation of the hypothesis.OBJETIVOS: avaliar fatores de risco envolvendo exposições ambientais e ocupacionais dos pais associadas com a ocorrência de fendas orofaciais em um grupo de crianças brasileiras. MÉTODOS: estudo caso-controle de base secundária reuniu 274 casos de portadores de fendas lábio-palatinas (FL±Pe fendas palatinas isoladas e 548 controles (1:2. Foram analisadas as variáveis proximidade residencial a área industriais, exposição a inseticidas comerciais, pesticidas agrícolas, e usados no controle de vetores, bem como várias exposições ocupacionais. Os resultados foram obtidos através de análise de regressão condicional

  20. Peroneal nerve palsy due to compartment syndrome after facial plastic surgery Paralisia de nervo fibular devido a síndrome compartimental após cirurgia plástica da face

    Directory of Open Access Journals (Sweden)

    Clécio O. Godeiro-Júnior

    2007-09-01

    índrome compartimental crônica. Ele fazia uso de anabolizantes e venlafaxina, não relatado no início do quadro, e a agitação poderia ser explicada por uma síndrome serotoninérgia desencadeada pela interação deste último medicamento e haloperidol. A rabdomiólise secundária a estes eventos causou edema e isquemia nos compartimentos anteriores de ambos os membros inferiores, levando a uma compressão secundária do nervo fibular. O caso em questão ilustra a importância do diagnóstico precoce da síndrome compartimental pois, caso contrário, mesmo com fasciotomia, uma complicação permanente devido à compressão de nervos periféricos pode se estabelecer.

  1. Absorbed Dose and Dose Equivalent Calculations for Modeling Effective Dose

    Science.gov (United States)

    Welton, Andrew; Lee, Kerry

    2010-01-01

    While in orbit, Astronauts are exposed to a much higher dose of ionizing radiation than when on the ground. It is important to model how shielding designs on spacecraft reduce radiation effective dose pre-flight, and determine whether or not a danger to humans is presented. However, in order to calculate effective dose, dose equivalent calculations are needed. Dose equivalent takes into account an absorbed dose of radiation and the biological effectiveness of ionizing radiation. This is important in preventing long-term, stochastic radiation effects in humans spending time in space. Monte carlo simulations run with the particle transport code FLUKA, give absorbed and equivalent dose data for relevant shielding. The shielding geometry used in the dose calculations is a layered slab design, consisting of aluminum, polyethylene, and water. Water is used to simulate the soft tissues that compose the human body. The results obtained will provide information on how the shielding performs with many thicknesses of each material in the slab. This allows them to be directly applicable to modern spacecraft shielding geometries.

  2. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  3. When is a dose not a dose?

    International Nuclear Information System (INIS)

    Green, Patrick

    1992-01-01

    There is confusion over radiation dose limits between the International Commission on Radiological Protection, the National Radiological Protection Board and the Ministry of Agriculture, Fisheries and Food (MAFF), reports a Friends of the Earth's radiation campaigner. MAFF is suggesting the inadequate ICRP public dose limit does not apply to public exposures which arise from environmental contamination from past radioactive discharges. (author)

  4. Riscos ocupacionais de uma indústria calçadista sob a ótica dos trabalhadores Riesgos laborales de una industria de calzado en la visión de los trabajadores Occupational risks of a shoe industry from the workers' perspective

    Directory of Open Access Journals (Sweden)

    Fernanda Reinher da Luz

    2013-02-01

    Full Text Available O estudo teve como objetivo identificar os riscos ocupacionais de uma indústria calçadista sob a ótica dos trabalhadores, bem como as medidas preventivas adotadas por eles contra os riscos. Realizou-se um estudo qualitativo, descritivo. A amostra foi composta por quinze trabalhadores. Os dados foram coletados por entrevista semiestruturada e analisados à luz da análise de conteúdo. Foram respeitados os aspectos éticos e a pesquisa foi aprovada pelo Comitê de Ética em Pesquisa da Universidade Regional do Noroeste do Estado do Rio Grande do Sul. Os resultados apontam que os trabalhadores são conhecedores dos riscos do seu processo de trabalho, faziam uso de medidas de proteção individual e a empresa disponibilizava dispositivos de segurança, informando e realizando, periodicamente, visitas aos setores, na perspectiva de desenvolver ações educativas.Estudio cualitativo descriptivo, que tuve como objetivo identificar los riesgos laborales de una industria de calzado, así como las medidas preventivas adoptadas frente a los riesgos, en la visión de los trabajadores. La muestra fue compuesta por quince trabajadores y los datos fueran obtenidos por entrevista semi-estructurada y analizados a luz de la analísis de contenido. Los aspectos éticos fueran respetados y la investigación fue aprobada por el Comité de Ética en Pesquisa de la Universidad Regional del Estado de Rio Grande do Sul. Los resultados apuntaran que los trabajadores conocen los riesgos de su proceso de trabajo, hacen uso de medidas de protección personal, y que la empresa proporciona dispositivos de seguridad, informando y realizando visitas periódicas a los sectores con el fin de desarrollar actividades educativas.This is a qualitative and descriptive study, which aimed to identify the occupational risks of a shoe industry, as well as the preventive measures taken against those risks, from the workers' perspective. The sample consisted of fifteen workers. Data

  5. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  6. Change of the natural radiation exposure due to agriculture and industrial activities in a high natural radioactivity area from Brazil; Modificacao da exposicao a radiacao natural devido a atividades agricolas e industriais numa area de radioatividade natural elevada no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Silva Amaral, E.C. da

    1992-12-31

    The Pocos de Caldas Plateau, Minas Gerais State one of the biggest alkaline intrusions in the world. This study has shown the expected value for the mean annual radiation exposure due to the agricultural activities ranges from 6 up to 14 mSv/a depending on the age and living habits of the population group. The inhalation exposure of radon, thoron and their progenies represents the largest radiological health hazard (70-90%); this is followed by the external gamma irradiation from soil (10-25%). Ingestion of natural radionuclides with local food is only of minor radiological consequence. It was found that the lethal cancer risk might increase by 4% for a person born at the plateau, living and working there for the rest of her life. For the remote population the consumption the consumption of food products exported from the plateau leads to an expected value for the collective dose of 19 man Sv/a. This corresponding nominally to the small calculated number of 1 additional case of cancer per year. Therefore the main radiation impact of the agricultural activities are not the increased concentrations of natural radionuclides in food products but the fact that they are produced there with human labor and thus increasing the radiation exposure to a large number of farm workers and their families that move for occupational reasons to that region. The radiation exposure due to the mining and milling activities is, in spite of the significant increase of radionuclide activity concentrations in river waters, only of the order of 0.3 mSv/a. However as a recognized industrial source the ICRP dose limitation system has to be applied. Under this aspect the exposure calculated here, 0.3 mSv/a, should be considered as acceptable. (author). 93 refs, 16 figs, 58 tabs.

  7. Biological dose estimation

    African Journals Online (AJOL)

    a radiation. •. In exposure. Biological dose estimation involving low-dose. S. JANSEN, G. J. VAN HUYSSTEEN. Summary. Blood specimens were collected from 8 people 18 days after they had been accidentally exposed to a 947,2 GBq iridium-. 192 source during industrial application. The equivalent whole-body dose ...

  8. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  9. Development of methodologies for internal exposure assessment due to the radiopharmaceutical {sup 18}FDG; Desenvolvimento de metodologias para avaliacao da exposicao ocupational interna devido ao radiofarmaco {sup 18}FDG

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Isabelle Viviane Batista de

    2013-07-01

    The production of {sup 18}F has increased in the last decade. It is produced basically for the synthesis of {sup 18}F- fluorodeoxyglucose ({sup 18}FDG), the main radiopharmaceutical used in PET (Positron Emission Tomography) scans. The growth in the frequency of these tests resulted in rise of the number of occupationally exposed individuals (OEI) to the radionuclide {sup 18}F as {sup 18}FDG, increasing thereby the probability of its accidental incorporation. This study aimed to implement optimized techniques for assessing internal exposures of individuals occupationally exposed through both in vivo and in vitro bioassay methods during production and handling of {sup 18}FDG at the Divisao de Producao de Radiofarmacos (DIPRA), Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN). The in vivo monitoring was conducted at the Laboratorio de Dosimetria Interna, Divisao de Laboratorios Tecnico-Cientificos (DILAB). For this bioassay method, measurements were done with a 3x3' NaI(Tl) scintillation detector coupled to Genie 2000 software. The calibration of the system was performed with a brain phantom containing a standard liquid source of {sup 22}Na to simulate a contaminated individual. The calibration of the HPGe coaxial detector for in vitro monitoring was performed at the Laboratorio de Medidas de Atividade de Radionuclideos (DIPRA/CRCN-NE/CNEN) with a standard source of {sup 22}Na. Base on the calibration factors, it was possible to determine the minimum detectable activities (MDA) for the systems by using direct measurements and simulation of uncontaminated urine. Then, through the biokinetic models published by ICRP 106 and edited by the AIDE software (version 6.0), it was possible to estimate the minimum detectable effective dose (MDED), which evaluates the detection sensitivity of the techniques developed. The MDED was estimated for in vivo and in vitro measurements performed 2.4 hours after the occurrence of incorporation by ingestion, since

  10. Registration of radiation doses

    International Nuclear Information System (INIS)

    2000-02-01

    In Finland the Radiation and Nuclear Safety Authority (STUK) is maintaining the register (called Dose Register) of the radiation exposure of occupationally exposed workers in order to ensure compliance with the principles of optimisation and individual protection. The guide contains a description of the Dose Register and specifies the responsibilities of the party running a radiation practice to report the relevant information to the Dose Register

  11. Afastamento do trabalho por transtornos mentais e estressores psicossociais ocupacionais

    Directory of Open Access Journals (Sweden)

    João Silvestre Silva-Junior

    2015-12-01

    Full Text Available RESUMO: Introdução: Os transtornos mentais são a terceira principal causa de concessão de benefício previdenciário por incapacidade no Brasil. A exposição ocupacional a estressores psicossociais pode comprometer a saúde mental dos trabalhadores. Cabe ao perito médico previdenciário caracterizar se o adoecimento incapacitante está relacionado com as condições de trabalho. Objetivo: Avaliar os fatores associados ao afastamento do trabalho por transtornos mentais relacionados ao trabalho, em especial a percepção dos trabalhadores sobre fatores psicossociais no trabalho. Métodos: Estudo analítico realizado em São Paulo com 131 requerentes de auxílio-doença por transtornos mentais. Foram preenchidos questionários sociodemográfico, de hábitos/estilo de vida e fatores psicossociais no trabalho. Resultados: Os quadros mais frequentes foram transtornos depressivos (40,4%. Entre todos os requerimentos, 23,7% foram considerados relacionados ao trabalho. O perfil da maioria dos participantes era: sexo feminino (68,7%, até 40 anos de idade (73,3%, casado/união estável (51,1%, escolaridade igual ou superior a 11 anos (80,2%, não tabagista (80,9%, não ingeria bebida alcoólica (84%, fazia atividade física (77,9%. Sobre os fatores psicossociais, prevaleceu trabalho de alta exigência (56,5%, baixo apoio social (52,7%, desequilíbrio esforço-recompensa (55,7% e comprometimento excessivo (87,0%. Não houve associação estatística entre casos de transtornos mentais relacionados ao trabalho e as variáveis independentes. Conclusão: A concessão do benefício auxílio-doença acidentário não foi associada a variáveis sóciodemográficas, hábitos/estilo de vida ou fatores psicossociais no trabalho. A exposição ocupacional a estressores psicossociais esteve presente no relato da maioria dos trabalhadores afastados do trabalho por transtornos mentais. Entretanto, diversos casos não foram reconhecidos pela perícia médica previdenciária como relacionados ao trabalho, o que pode ter influenciado nos resultados das associações.

  12. Triagem de hemoglobinopatias e avaliação da degeneração oxidativa da hemoglobina em trabalhadores portadores do traço falciforme (HbAS, expostos a riscos ocupacionais Screening of abnormal hemoglobin and the evaluation of oxidative degeneration of hemoglobin among workers with the sickle cell trait (HbAS, exposed to occupational hazards

    Directory of Open Access Journals (Sweden)

    Isaac L. Silva Filho

    2005-09-01

    Full Text Available Desde os anos 40, quando foram realizados os primeiros trabalhos de triagem para hemoglobinas anormais na população brasileira, tem sido descrita uma elevada prevalência destas em nosso meio, especialmente a hemoglobina S que, a despeito da heterogeneidade de sua distribuição geográfica, quase sempre é a mais freqüente nas diversas regiões estudadas. Aliado a este fato, estudos recentes têm demonstrado uma maior susceptibilidade desta a oxidação, tornando-a mais sensível ao estresse oxidativo que a hemoglobina normal (HbAA, mesmo em se tratando de portadores heterozigotos (HbAS. Tendo em vista que algumas substâncias químicas são comprovadamente meta-hemoglobinizantes, que alguns fatores ambientais podem influenciar na morbidade da anemia falciforme e também o pouco e controverso conhecimento de que se dispõe a respeito de portadores do traço falciforme, este estudo, além da pesquisa de hemo-globinas anormais, avaliou também a degeneração oxidativa da hemoglobina, através da pesquisa de corpos de Heinz e dosagem de meta-hemoglobina em uma população de trabalhadores portadores do traço falciforme, expostos a riscos ocupacionais. Foram triadas 2.190 amostras sangüíneas entre Outubro de 1999 e Dezembro de 2001. A população estudada foi constituída de trabalhadores de ambos os sexos com idades variando entre 18 e 76 anos. Os resultados evidenciaram 4,7% portadores de hemoglobinas anormais na população analisada, sendo que a hemoglobina S foi a mais freqüente - 3,2% (71. Trabalhadores portadores do traço falciforme apresentaram uma chance 14 vezes maior de possuírem valores aumentados de meta-hemoglobina em relação aos trabalhadores com genótipo AA, porém, esta diferença não foi estatisticamente significativa.Hemoglobinopathies are frequent hereditary diseases in Brazilian population and have been a public health problem. This study reports the screening of abnormal hemoglobin among Fiocruz`s employees, as

  13. Riscos ocupacionais e mecanismos de autocuidado do trabalhador de um centro de material e esterilização Riesgos laborales y mecanismos para autocuidado en trabajadores de un centro de materiales y esterilización Occupational risks and self-care mechanisms used by the sterilization and materials processing department workers

    Directory of Open Access Journals (Sweden)

    Marcia Cristina Guimarães Espindola

    2012-03-01

    Full Text Available O objetivo do estudo foi investigar riscos ocupacionais e mecanismos de autocuidado utilizados pelos auxiliares e técnicos de enfermagem que trabalham em um Centro de Material e Esterilização. Estudo descritivo, de abordagem qualitativa, realizado junto a 13 trabalhadores de um hospital regional de médio porte, localizado no interior do estado do Rio Grande do Sul. Os dados foram coletados no primeiro semestre de 2010, mediante entrevistas, e analisados pelo método da análise temática. O risco ocupacional mais referido pelos trabalhadores foi o físico, caracterizado pelo calor. Uso de equipamentos de proteção individual, hidratação e imunizações são alguns dos mecanismos utilizados pelos sujeitos para a prevenção de agravos e a promoção de sua saúde. A cogestão entre os sujeitos que vivenciam o trabalho e os gestores na discussão e elaboração de ações de melhoria das condições laborais, pode construir ambiências seguras aos usuários do serviço e aos produtores de saúde.El objetivo del estudio fue investigar los riesgos laborales y los mecanismos de auto-cuidado utilizados por los auxiliares y técnicos de enfermería que trabajan en un Centro de Material y Esterilización. Estudio cualitativo, descriptivo, realizado entre 13 trabajadores de un hospital regional mediano, situado en el Rio Grande do Sul, Brasil. Los datos fueron recolectados en el primer semestre de 2010, a través de entrevistas y se analizaron mediante análisis temático. El riesgo laboral más frecuente de los trabajadores es el físico, caracterizado por el calor. Uso de equipo de protección personal, la hidratación y vacunas son mecanismos utilizados por los individuos para la prevención de enfermedades y promoción de su salud. El co-manejo entre los trabajadores y la gestión en la discusión y preparación de acciones para mejorar las condiciones de trabajo pueden crear un ambiente seguro a los usuarios y a los productores de la salud

  14. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  15. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  16. Occupational dose constraint

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle; Xavier, Ana Maria

    2005-01-01

    The revision process of the international radiological protection regulations has resulted in the adoption of new concepts, such as practice, intervention, avoidable and restriction of dose (dose constraint). The latter deserving of special mention since it may involve reducing a priori of the dose limits established both for the public and to individuals occupationally exposed, values that can be further reduced, depending on the application of the principle of optimization. This article aims to present, with clarity, from the criteria adopted to define dose constraint values to the public, a methodology to establish the dose constraint values for occupationally exposed individuals, as well as an example of the application of this methodology to the practice of industrial radiography

  17. Dose response relationship at low doses

    International Nuclear Information System (INIS)

    Schull, W.J.

    1992-01-01

    The data that have accrued in Hiroshima and Nagasaki on the effects of ionizing radiation on the developing human brain are reviewed. Effects considered are severe mental retardation, lowered IQ scores, decline in school performance, seizures, other neuropsychological effects, and small head size. All these factors may be related to radiation doses received by the mother during pregnancy. (L.L.) 3 figs., tab., 7 refs

  18. Análise matemática e biológica dos modelos de estimativa de perdas de rendimento na cultura devido à interferência de plantas daninhas Mathematical and biological analysis of the models for estimating culture yield losses due to weed interference

    Directory of Open Access Journals (Sweden)

    C. Adati

    2006-01-01

    Full Text Available As plantas daninhas acarretam reduções no rendimento das culturas agrícolas. Os modelos matemáticos de estimativa de perda de rendimento na cultura devido à interferência dessas plantas podem ser instrumentos úteis à tomada de decisão de manejo. Se for possível prever as perdas de rendimento, será possível decidir se é viável ou não a aplicação de uma medida de controle. Há na literatura vários modelos matemáticos empíricos de regressão lineares, não-lineares e polinomiais usados para estimar as perdas de rendimento devido às plantas daninhas. O presente trabalho teve como objetivo apresentar uma análise dos modelos matemáticos presentes na literatura utilizados para estimar as perdas de rendimento que as plantas daninhas acarretam à cultura, considerando o ajuste matemático às observações e a descrição biológica do comportamento dessas perdas.The presence of weeds in any production system involving plants causes crop yield losses. Mathematical models for crop yield loss estimation due to the interference of weeds can be useful tools for decision-making management strategies. If it is possible to predict crop yield loss, it will be possible to decide whether it is viable to apply control measures. There are several empirical models in the literature used to estimate crop yield loss due to the presence of weeds, which are linear, non linear and polynomial. The goal of this work is to present an analysis of the existing mathematical models used to estimate crop yield loss due to weeds by considering both their mathematical fit and biological behavior.

  19. Comportamento dos acadêmicos, docentes e técnicos-administrativos da clínica odontológica da Unioeste: riscos ocupacionais e atividades desenvolvidas - DOI: 10.4025/actascihealthsci.v30i1.587 Behavior of university students, faculty and administrative technicians at the Unioeste dental clinic: occupational risks and performed activities - DOI: 10.4025/actascihealthsci.v30i1.587

    Directory of Open Access Journals (Sweden)

    Débora Cristina Ignácio Alves

    2008-07-01

    Full Text Available Os profissionais, usuários e demais envolvidos no atendimento odontológico estão expostos a diversos riscos ocupacionais. A pesquisa teve como objetivos identificar os riscos ocupacionais existentes, os procedimentos realizados, os equipamentos de proteção individual utilizados, os treinamentos recebidos e os acidentes sofridos. A amostra do tipo não probabilística foi composta por 61 acadêmicos, 27 docentes e 12 técnicos-administrativos. Os dados foram coletados através da observação dos atendimentos realizados e um questionário semi-estruturado. Das vinte e oito observações realizadas, a maioria foi na Clinica Integrada do Adulto (53,6%, seguida pela Clínica Integrada Infantil (35,7% e na Dentística (10,7%. Para a totalidade dos docentes e técnicos existem riscos, sendo referidos o biológico e de acidente. A maioria (98,4% dos acadêmicos considera a existência de riscos, contudo 1,6% a negam e 8,2% deles sofreram acidentes. Quanto ao uso de Equipamentos de Proteção Individual (EPI, 25% dos técnicos-administrativos não têm o hábito de usá-los. Embora os acadêmicos e docentes tenham relatado seu uso como forma de proteção, nem todos citaram a paramentação completa. Assim, o registro de acidentes e a baixa adesão aos EPI´s evidenciou a necessidade de treinamento e conscientização dos envolvidos.Professionals, users and other people involved in the dental treatment services are exposed to several kinds of risks occupational. A research was carried out aiming at identifying the existence of risks occupational, the proceedings performed, the protection equipment used in the treatments, the training received and the accidents suffered. The sample of the type not probabilística was composed of 61 university students, 27 professors and 12 administrative technicians. The data collecting was carried out in two stages: the observation of the treatments done and a semi-structured questionnaire. Most of the twenty

  20. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  1. Doses from radioactive methane

    International Nuclear Information System (INIS)

    Phipps, A.W.; Kendall, G.M.; Fell, T.P.; Harrison, J.D.

    1990-01-01

    A possible radiation hazard arises from exposure to methane labelled with either a 3 H or a 14 C nuclide. This radioactive methane could be released from a variety of sources, e.g. land burial sites containing radioactive waste. Standard assumptions adopted for vapours would not apply to an inert alkane like methane. This paper discusses mechanisms by which radioactive methane would irradiate tissues and provides estimates of doses. Data on skin thickness and metabolism of methane are discussed with reference to these mechanisms. It is found that doses are dominated by dose from the small fraction of methane which is inhaled and metabolised. This component of dose has been calculated under rather conservative assumptions. (author)

  2. Controllable dose; Dosis controlable

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T.; Anaya M, R.A. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: jtar@nuclear.inin.mx

    2004-07-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  3. Acetaminophen dosing for children

    Science.gov (United States)

    ... your child, call your provider. Proper Dosing of Suppositories If your child is vomiting or will not take oral medicine, you can use suppositories. Suppositories are placed in the anus to deliver ...

  4. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  5. Ibuprofen dosing for children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000772.htm Ibuprofen dosing for children To use the sharing features ... much of this medicine can be harmful. How Ibuprofen can Help Your Child Ibuprofen is a type ...

  6. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  7. Gonadal doses from radiotherapy

    International Nuclear Information System (INIS)

    Solomon, S.B.; Morris, N.D.

    1980-06-01

    The method of calculation of gonadal doses arising from different radiotherapeutic procedures is described. The measurement of scatter factors to the gonads from superficial and deep therapy is detailed and the analytic fits to the experimental data, as a function of field position, field size and beam energy are given. The data used to calculate the gonadal doses from treatments using linear accelerators, teletherapy and sealed sources are described and the analytic fits to the data given

  8. INSUFICIÊNCIA RENAL AGUDA DEVIDO À RABDOMIÓLISE

    OpenAIRE

    Guilherme Gomide CABRAL; Leticia Mattar MONICE; Lorena Rocha Dias MACHADO; Luana Modesto Lopes CALDEIRA; Lucas Roquim SILVA; Hudson Araújo COUTO

    2015-01-01

    Atividades físicas são importantes para a saúde de qualquer individuo, porém, quando realizadas em condições inapropriadas, baseando-se em exercícios muito violentos, pode ocorrer rabdomiólise, sendo uma de suas consequências, a insuficiência renal aguda (IRA). Os dois principais fatores que predispõem à IRA por rabdomiólise são: a hipovolemia secundária ao sequestro de volume da musculatura acometida e a presença de urina ácida. A rabdomiólise caracteriza-se pela lesão da musculatura estriad...

  9. Acidentes ocupacionais por exposição a material biológico entre a equipe multiprofissional do atendimento pré-hospitalar Accidentes ocupacionales por exposición a material biológico entre el equipo multiprofesional de atención pre hospitalaria Occupational accidents due to exposure to biological material in the multidisciplinary team of the emergency service

    Directory of Open Access Journals (Sweden)

    Adriana Cristina Oliveira

    2009-09-01

    Full Text Available Estudo transversal, tipo survey, realizado com a equipe multiprofissional de Atendimento Pré-hospitalar (APh de Belo Horizonte, entre junho e dezembro de 2006. Objetivou-se determinar a incidência dos acidentes ocupacionais por exposição a material biológico, condutas pós-acidente, e fatores demográficos determinantes. Utilizou-se questionário estruturado, análise descritiva, cálculo de incidências e regressão logística. A incidência de acidentes com material biológico foi de 20,6%: 40,8% por pérfuro-cortantes e 49,0% por fluidos corporais; 35,3% entre médicos e 24,0% entre enfermeiros. Condutas pós-acidente: sem avaliação médica, 63,3%; subnotificação, 81,6%; nenhuma conduta, 55,0%; e, sem acompanhamento sorológico, 61,2%. Estiveram associados ao acidente: tempo na instituição (Odds ratio-OR 2,84; Intervalo de confiança-IC 95% 1,22-6,62, lotação na Unidade de Suporte Avançado (OR 4,18; IC 95% 1,64-10,64; interação: tempo na instituição e lotação na Unidade de Suporte Básico (OR 0,27; IC 95% 0,07-1,00. Sugere-se a implantação de protocolos pós-acidentes, visando a sua redução; a subnotificação e o aumento do acompanhamento pós-acidente.Estudio transversal, tipo survey, realizado con el equipo multiprofesional de Atención Pre Hospitalaria (APh de Belo Horizonte entre junio y diciembre de 2006. Se objetivó determinar la incidencia de los accidentes ocupacionales por exposición a material biológico, las conductas después del accidente y los factores demográficos determinantes. Se utilizó un cuestionario estructurado, el análisis descriptivo, el cálculo de incidencias y la regresión logística. La incidencia de accidentes con material biológico fue de 20,6%: 40,8% por punzo cortantes y 49,0% fluidos corporales; 35,3% entre médicos y 24,0% entre enfermeros. Conductas después del accidente: sin evaluación médica, 63,3%; subnotificación, 81,6%; ninguna conducta, 55,0%; y, sin acompa

  10. Trabalhador portuário: perfil de doenças ocupacionais diagnosticadas em serviço de saúde ocupacional Trabajador portuario: perfil de enfermedades ocupacionales diagnosticadas en un servicio de salud ocupacional Dock worker: profile of occupational diseases diagnosed in an occupational health service

    Directory of Open Access Journals (Sweden)

    Marlise Capa Verde de Almeida

    2012-01-01

    Full Text Available OBJETIVO: Identificar as doenças diagnosticadas em trabalhadores portuários avulsos, atendidos em um ambulatório de medicina do trabalho portuário. MÉTODOS: Estudo quantitativo descritivo com análise retrospectiva, que apresentou como fonte de dados as fichas de atendimento médico dos trabalhadores portuários avulsos entre 2000 e 2009. A coleta de dados desenvolveu-se mediante aplicação de um formulário predeterminado e procedeu-se à análise quantitativa descritiva em 953 fichas médicas dos trabalhadores. RESULTADOS: totalizou-se 953 fichas médicas (94,7%, das quais 90,47% pertenciam a trabalhadores do sexo masculino, 52% na faixa etária acima de 50 anos e 51,7% com mais de 19 anos de atuação. Identificaram-se 527 diagnósticos, sendo os principais relacionados ao trabalho: hipertensão (8,3%, lombalgia (6,2%, outras doenças pulmonares (1,7% e episódios depressivos (1,2%. CONCLUSÃO: constatou-se o acometimento do trabalhador por patologias ocupacionais de ordem mental, circulatória, respiratória e osteomuscular, evidenciando morbidades que o afetam e interferem em sua qualidade de vida e na produtividade das atividades laborais.OBJETIVO: Identificar las enfermedades diagnosticadas en trabajadores portuarios independientes, atendidos en un consultorio externo de medicina del trabajo portuario. MÉTODOS: Estudio cuantitativo descriptivo con análisis retrospectivo, que presentó como fuente de datos las fichas de atención médica de los trabajadores portuarios independientes entre 2000 y 2009. La recolección de los datos se desarrolló mediante la aplicación de un formulario estructurado y se procedió a realizar el análisis cuantitativo descritivo de 953 fichas médicas de los trabajadores. RESULTADOS: De un total de 953 fichas médicas (94,7%, el 90,47% pertenecían a trabajadores del sexo masculino, el 52% se encontraba en el grupo etáreo arriba de los 50 años y el 51,7% con más de 19 años de actuación. Se

  11. Assessment of internal doses

    CERN Document Server

    Rahola, T; Falk, R; Isaksson, M; Skuterud, L

    2002-01-01

    There is a definite need for training in dose calculation. Our first course was successful and was followed by a second, both courses were fully booked. An example of new tools for software products for bioassay analysis and internal dose assessment is the Integrated Modules for Bioassay Analysis (IMBA) were demonstrated at the second course. This suite of quality assured code modules have been adopted in the UK as the standard for regulatory assessment purposes. The intercomparison measurements are an important part of the Quality Assurance work. In what is known as the sup O utside workers ' directive it is stated that the internal dose measurements shall be included in the European Unions supervision system for radiation protection. The emergency preparedness regarding internal contamination was much improved by the training with and calibration of handheld instruments from participants' laboratories. More improvement will be gained with the handbook giving practical instructions on what to do in case of e...

  12. Dose Reduction Techniques

    International Nuclear Information System (INIS)

    WAGGONER, L.O.

    2000-01-01

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program

  13. Dose Reduction Techniques

    Energy Technology Data Exchange (ETDEWEB)

    WAGGONER, L.O.

    2000-05-16

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program.

  14. Radioactive cloud dose calculations

    International Nuclear Information System (INIS)

    Healy, J.W.

    1984-01-01

    Radiological dosage principles, as well as methods for calculating external and internal dose rates, following dispersion and deposition of radioactive materials in the atmosphere are described. Emphasis has been placed on analytical solutions that are appropriate for hand calculations. In addition, the methods for calculating dose rates from ingestion are discussed. A brief description of several computer programs are included for information on radionuclides. There has been no attempt to be comprehensive, and only a sampling of programs has been selected to illustrate the variety available

  15. Dose model for inhalation

    International Nuclear Information System (INIS)

    Raicevic, J.; Ninkovic, M.; Merkle, M.

    1997-01-01

    This paper deals with calculation of doses in the environment. There are in general five exposure pathways which are customarily considered within such calculations: cloud shine, ground shine, inhalation after resuspension and ingestion. Since in fact each of these exposure pathways is represented by an independent mechanism, it is usual to consider these environmental dose models separately for each exposure pathway. As one example, the inhalation of the material from the radioactive passing cloud, as well as the inhalation of the radioactive material resuspended in the air are considered, giving the same formulas which are used in the new european accident consequence assessment code system COSYMA. (author)

  16. Dose Reduction Techniques

    CERN Document Server

    Waggoner, L O

    2000-01-01

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the sm...

  17. When is a dose not a dose?

    International Nuclear Information System (INIS)

    Bond, V.P.

    1991-01-01

    Although an enormous amount of progress has been made in the fields of radiation protection and risk assessment, a number of significant problems remain. The one problem which transcends all the rest, and which has been subject to considerable misunderstanding, involves what has come to be known as the 'linear non-threshold hypothesis', or 'linear hypothesis'. Particularly troublesome has been the interpretation that any amount of radiation can cause an increase in the excess incidence of cancer. The linear hypothesis has dominated radiation protection philosophy for more than three decades, with enormous financial, societal and political impacts and has engendered an almost morbid fear of low-level exposure to ionizing radiation in large segments of the population. This document presents a different interpretation of the linear hypothesis. The basis for this view lies in the evolution of dose-response functions, particularly with respect to their use initially in the context of early acute effects, and then for the late effects, carcinogenesis and mutagenesis. 11 refs., 4 figs

  18. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Um estudo comparativo sobre a identificação dos riscos ocupacionais por trabalhadores de enfermagem de duas Unidades Básicas de Saúde do município de São Paulo Un estudio comparativo sobre la identificación de los riesgos ocupacionales por trabajadores de enfermería de duas Unidades Basicas de Salud del municipio de São Paulo A comparative study about identification of occupational risks by nursing workers of two Basic Health Units of São Paulo

    Directory of Open Access Journals (Sweden)

    Rita de Cassia Gengo e Silva

    2002-03-01

    Full Text Available Os riscos ocupacionais do trabalho de enfermagem em Unidades Básicas de Saúde (UBS não têm sido frequentemente abordados, o que nos estimulou a realizar este estudo com os objetivos de comparar a percepção dos trabalhadores deenfermagem de duas UBS sobre esses riscos e estabelecer um paralelo sobre os problemas de saúde relacionados com a suaexposição. Os dados foram coletados através da entrevista e analisados segundo suas frequências relativa e absoluta ecoeficientes de risco. Os maiores coeficientes de risco estão relacionados a exposição aos riscos biológicos. Conclui-se que os trabalhadores têm dificuldade em apreender a gênese dos riscos ocupacionais.Los riesgos ocupacionales del trabajo de enfermeria en Unidades Básicas de Salud (UBS no han sido frecuentemente abordados, lo que nos estimuló en realizar este estudio con el objetivo de comparar la percepción de los trabajadores de enfermería de dos UBS sobre estos riesgos y establecer un paralelo sobre los problemas de salud relacionados con suexposición. Los datos fueron recolectados a través de una entrevista y analizados según sus frecuencias relativa, absolutay coeficientes de riesgo. Los mayores coeficientes de riesgo estan relacionados a la exposición de riesgos biológicos. Seconcluye que los trabaj adores tienen dificultades en aprender la génesis de los riesgos ocupacionales.Occupational risks of nursing work in Basic Health Units have not been study frequently, so it stimulate us to develop this paper, whose objective are: to compare the perception of nursing workers of two Basic Health Units about these risks and toestablish a parallel between the health problems with their exposition to occupational risks- Data were collected by aninterview and were analyzed according to their frequencies. Biological risks were observed more frequently. The conclusionsshow that nursing workers have difficult to understand the genesis of occupational risks.

  20. Tumor significant dose

    International Nuclear Information System (INIS)

    Supe, S.J.; Nagalaxmi, K.V.; Meenakshi, L.

    1983-01-01

    In the practice of radiotherapy, various concepts like NSD, CRE, TDF, and BIR are being used to evaluate the biological effectiveness of the treatment schedules on the normal tissues. This has been accepted as the tolerance of the normal tissue is the limiting factor in the treatment of cancers. At present when various schedules are tried, attention is therefore paid to the biological damage of the normal tissues only and it is expected that the damage to the cancerous tissues would be extensive enough to control the cancer. Attempt is made in the present work to evaluate the concent of tumor significant dose (TSD) which will represent the damage to the cancerous tissue. Strandquist in the analysis of a large number of cases of squamous cell carcinoma found that for the 5 fraction/week treatment, the total dose required to bring about the same damage for the cancerous tissue is proportional to T/sup -0.22/, where T is the overall time over which the dose is delivered. Using this finding the TSD was defined as DxN/sup -p/xT/sup -q/, where D is the total dose, N the number of fractions, T the overall time p and q are the exponents to be suitably chosen. The values of p and q are adjusted such that p+q< or =0.24, and p varies from 0.0 to 0.24 and q varies from 0.0 to 0.22. Cases of cancer of cervix uteri treated between 1978 and 1980 in the V. N. Cancer Centre, Kuppuswamy Naidu Memorial Hospital, Coimbatore, India were analyzed on the basis of these formulations. These data, coupled with the clinical experience, were used for choice of a formula for the TSD. Further, the dose schedules used in the British Institute of Radiology fraction- ation studies were also used to propose that the tumor significant dose is represented by DxN/sup -0.18/xT/sup -0.06/

  1. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  2. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  3. Entrance surface dose according to dose calculation: Head and wrist

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ho Jin [Dept. Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Han, Jae Bok; Song, Jong Nam; Choi, Nam Gil [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-09-15

    This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiographic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

  4. Occupational dose assessment and national dose registry system in Iran

    International Nuclear Information System (INIS)

    Jafari-Zadeh, M.; Nazeri, F.; Hosseini-Pooya, S. M.; Taheri, M.; Gheshlaghi, F.; Kardan, M. R.; Babakhani, A.; Rastkhah, N.; Yousefi-Nejad, F.; Darabi, M.; Oruji, T.; Gholamali-Zadeh, Z.; Karimi-Diba, J.; Kazemi-Movahed, A. A.; Dashti-Pour, M. R.; Enferadi, A.; Jahanbakhshian, M. H.; Sadegh-Khani, M. R.

    2011-01-01

    This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H p (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed. (authors)

  5. Use of MCNP to compare the response of dose deposited in the TLD 100, TLD 600 and TLD 700 in radiation fields due to {sup 60}Co and {sup 241}AmBe source; Uso do MCNP para comparacao das respostas de dose depositada nos TLD 100, TLD 600 e TLD 700 em campos de irradiacao devido a fontes de {sup 60}Co e {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-08-15

    The successes of Boron Neutron Capture Therapy (BNCT) depend on the ability to deliver an adequate irradiation field to the target cells. Neutron beams used in BNCT are mostly driven from reactors and therefore, not only have a neutron energy range which far exceeds the thermal region but also do have a great gamma component. Beam characterization and dosimetry are consequently one of the essential procedures to be overcome to properly apply this technique. One of the methods currently used in mixed field (field containing both neutron and gamma) characterization, lies on the use of a pair of detectors with distinct responses to each beam component. But this technique needs to be better understood of how each thermoluminescent dosimeter (TLD) behaves in a mixed field or in a pure field. This work presents the results of a set of simulations performed in order to analyze the response of three ordinary types of TLDs - TLD 100, TLD 600 and TLD 700 - submitted to different irradiation fields from a Cobalt source and an Americium-Beryllium source inside a paraffin disk. And is also a possible method for performing the selection and calibration of theses TLDs. (author)

  6. Doses from radiation exposure

    CERN Document Server

    Menzel, H G

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection's (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP's 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effecti...

  7. Small dose... big poison.

    Science.gov (United States)

    Braitberg, George; Oakley, Ed

    2010-11-01

    It is not possible to identify all toxic substances in a single journal article. However, there are some exposures that in small doses are potentially fatal. Many of these exposures are particularly toxic to children. Using data from poison control centres, it is possible to recognise this group of exposures. This article provides information to assist the general practitioner to identify potential toxic substance exposures in children. In this article the authors report the signs and symptoms of toxic exposures and identify the time of onset. Where clear recommendations on the period of observation and known fatal dose are available, these are provided. We do not discuss management or disposition, and advise readers to contact the Poison Information Service or a toxicologist for this advice.

  8. First dose in man

    DEFF Research Database (Denmark)

    Hougaard Christensen, Mette Marie

    2011-01-01

    Du er blevet ansat som læge i et lægemiddelfirma med ansvar for planlægning og sikkerhed i fase 1 forsøg. Firmaet har udviklet tre dopamin D2-receptor antagonister til behandling af skizofreni. Lægemidlerne har undergået et omfattende farmakologisk, toksikologisk og farmaceutisk afprøvningsprogra...... fase 1 forsøg alias »First dose in man«....

  9. Dose calculation for electrons

    International Nuclear Information System (INIS)

    Hirayama, Hideo

    1995-01-01

    The joint working group of ICRP/ICRU is advancing the works of reviewing the ICRP publication 51 by investigating the data related to radiation protection. In order to introduce the 1990 recommendation, it has been demanded to carry out calculation for neutrons, photons and electrons. As for electrons, EURADOS WG4 (Numerical Dosimetry) rearranged the data to be calculated at the meeting held in PTB Braunschweig in June, 1992, and the question and request were presented by Dr. J.L. Chartier, the responsible person, to the researchers who are likely to undertake electron transport Monte Carlo calculation. The author also has carried out the requested calculation as it was the good chance to do the mutual comparison among various computation codes regarding electron transport calculation. The content that the WG requested to calculate was the absorbed dose at depth d mm when parallel electron beam enters at angle α into flat plate phantoms of PMMA, water and ICRU4-element tissue, which were placed in vacuum. The calculation was carried out by the versatile electron-photon shower computation Monte Carlo code, EGS4. As the results, depth dose curves and the dependence of absorbed dose on electron energy, incident angle and material are reported. The subjects to be investigated are pointed out. (K.I.)

  10. Dose reduction in evacuation proctography

    International Nuclear Information System (INIS)

    Hare, C.; Halligan, S.; Bartram, C.I.; Gupta, R.; Walker, A.E.; Renfrew, I.

    2001-01-01

    The goal of this study was to reduce the patient radiation dose from evacuation proctography. Ninety-eight consecutive adult patients referred for proctography to investigate difficult rectal evacuation were studied using a digital imaging system with either a standard digital program for barium examinations, a reduced dose digital program (both with and without additional copper filtration), or Video fluoroscopy. Dose-area products were recorded for each examination and the groups were compared. All four protocols produced technically acceptable examinations. The low-dose program with copper filtration (median dose 382 cGy cm 2 ) and Video fluoroscopy (median dose 705 cGy cm 2 ) were associated with significantly less dose than other groups (p < 0.0001). Patient dose during evacuation proctography can be reduced significantly without compromising the diagnostic quality of the examination. A digital program with added copper filtration conveyed the lowest dose. (orig.)

  11. Transit dose calculation in high dose rate brachytherapy (HDR ...

    African Journals Online (AJOL)

    Transit doses around a high dose rate 192Ir brachytherapy source were calculated using Sievert Integral at positions where the moving source was located exactly between two adjacent dwell positions. The correspond-ing transit dose rates were obtained by using energy absorption coefficients. Discrete step sizes of 0.25 ...

  12. Conversion of dose volume constraints to dose limits

    Energy Technology Data Exchange (ETDEWEB)

    Dai Jianrong [Department of Radiological Science, St Jude Children' s Research Hospital, Memphis, TN 38105 (United States); Zhu Yunping [Department of Radiological Science, St Jude Children' s Research Hospital, Memphis, TN 38105 (United States)

    2003-12-07

    The purpose of this study is to introduce two techniques for converting dosevolume constraints to dose limits for treatment planning optimization, and to evaluate their performance. The first technique, called dose-sorting, is based on the assumption that higher dose limits should be assigned to the constraint points receiving higher doses, and vice versa. The second technique, the hybrid technique, is a hybrid of the dose-sorting technique and the mixed integer linear programming (MILP) technique. Among all constraint points in an organ at risk, the dose limits for the points far from a dosevolume constraint are determined by dose-sorting, while the dose limits for the points close to a dosevolume constraint are determined by MILP. We evaluated the performance of the two new techniques for one treatment geometry by comparing them with the MILP technique. The dose-sorting technique had a high probability of finding the global optimum when no more than three organs at risk have dose-volume constraints. It was much faster than the MILP technique. The hybrid technique always found the global optimum when the MILP percentage (the percentage of constraint points for which the dose limits are determined by the MILP technique) was large enough, but its computation time increased dramatically with the MILP percentage. In conclusion, the dose-sorting technique and the hybrid technique with a low MILP percentage are clinically feasible.

  13. Tensão devido ao papel de cuidador entre cuidadores de crianças com câncer Tensión debido al rol de cuidador entre cuidadores de niños con cáncer Caregiver role strain in caregivers of children with cancer

    Directory of Open Access Journals (Sweden)

    Ana Raquel Medeiros Beck

    2007-10-01

    Full Text Available Pretendeu-se identificar a freqüência do diagnóstico de enfermagem `tensão devido ao papel do cuidador' e `risco para tensão devida ao papel do cuidador', entre 50 cuidadores de crianças portadoras de câncer, num hospital infantil especializado em doenças onco-hematológicas de Campinas, SP. O estudo foi transversal e descritivo, os dados foram coletados por meio do prontuário e de entrevista com o cuidador, utilizando-se formulário próprio. Apresentaram `tensão devido ao papel de cuidador 78% dos cuidadores e 100% tinham risco para tensão devida ao papel de cuidador, com a presença de, no mínimo, duas características definidoras e seis fatores de risco'. Conclui-se que os cuidadores de crianças com câncer têm alto risco para tensão devida ao papel de cuidador.Se pretendió identificar la frecuencia del diagnóstico de enfermería: `tensión debido al rol de cuidador' y `riesgo de tensión debida al papel de cuidador', entre 50 cuidadores de niños portadores de cáncer, en un hospital infantil especializado en enfermedades onco-hematológicas de Campinas, SP, Brasil. El estudio fué transversal y descriptivo, los datos fueron recogidos por medio de la ficha de la entrevista con el cuidador, utilizandose un formulario apropiado. Presentaron `tensión debida al papel del cuidador' 78% de los cuidadores, y 100% corrían riesgo de `tensión debido al rol de cuidador', con la presencia mínima de 2 características definidoras y 6 factores de riesgo. Se concluye que los cuidadores de niños con cáncer corren alto riesgo de tensión debida al papel de cuidadador'.The purpose of this study was to identify the frequency of nursing diagnoses "caregiver role strain" and "risk for caregiver role strain" in 50 caregivers of children with cancer in a specialized children's cancer hospital in Campinas, São Paulo. The data for this descriptive cross-sectional study was obtained from the patients' files and interviews held with the

  14. Dose-to-man studies

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Dose-to-Man Studies focused on developing computer data handling and computer modules which permit easy, rapid assessment of the dose to southeastern United States populations from routine or accidental releases of radionuclides to atmospheric and stream systems

  15. Dose. Detriment. Limit assessment

    International Nuclear Information System (INIS)

    Breckow, J.

    2015-01-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  16. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. (comps.)

    1991-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): Source terms; environmental transport environmental monitoring data; demographics, agriculture, food habits; environmental pathways and dose estimates.

  17. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. (comps.)

    1992-02-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demography, food consumption, and agriculture; environmental pathways and dose estimates.

  18. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Cannon, S.D.; Finch, S.M. (comps.)

    1992-10-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates):Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates.

  19. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. (comps.)

    1992-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates.

  20. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Cannon, S.D.; Finch, S.M.

    1992-10-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates):Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates

  1. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  2. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  3. Peripheral dose from megavolt beams

    International Nuclear Information System (INIS)

    Fraass, B.A.; van de Geijn, J.

    1983-01-01

    The peripheral dose (PD), defined as the dose outside of therapeutic radiation beams, has been investigated for 60 Co, 4-, 6-, and 10-MV x-ray machines. The measurements have been carried out down to dose levels of about 0.1% of the peak dose in the beam, since that dose level may be of clinical importance in some situations. The PD measurements for the various machines are qualitatively similar, which allows the identification of a simple basic data set which can characterize the PD for any particular machine. The PD has been separated into two components: in-phantom scatter dose and transmission (leakage) dose. Knowledge of the two components is important clinically when shielding is considered

  4. Sintomas vocais e sensações laríngeas em trabalhadores de uma usina de álcool e açúcar expostos a riscos ocupacionais Vocal symptoms and laryngeal sensations in workers of an ethanol and sugar mill exposed to occupational risks

    Directory of Open Access Journals (Sweden)

    Sylvia Boechat Coutinho

    2011-09-01

    Full Text Available OBJETIVO: Investigar os sintomas vocais e sensações laríngeas dos trabalhadores de uma usina de álcool e açúcar expostos a ruído e/ou substâncias químicas. MÉTODOS: Participaram 289 trabalhadores de uma usina de álcool e açúcar distribuídos em cinco grupos expostos (I- ruído; II- ruído, óleo, graxa, derivação de petróleo; III- ruído, ácidos, sulfatos, cloretos, nitratos; IV- ruído, poeiras respiráveis e sílica livre cristalizada; V- óleo, graxa, derivação de petróleo e um grupo controle que responderam o questionário Condições de Produção Vocal - Professor adaptado à categoria profissional. Os grupos foram comparados em relação aos sintomas vocais, sensações laríngeas, tabagismo e riscos físicos e químicos. Esta comparação foi realizada por meio de análise estatística. RESULTADOS: O sintoma vocal e a sensação laríngea mais relatados pelos trabalhadores foram voz grave e tosse com catarro, respectivamente. Considerando o risco físico no ambiente de trabalho, os grupos I e IV foram os que mais citaram presença de ruído. Devido à sua exposição, os mesmos aumentavam a intensidade da voz (Efeito de Lombard-Tarneaud e, assim, mencionaram sintomas vocais. Em relação aos riscos químicos no ambiente ocupacional, o grupo IV foi o que mais referiu presença de poeira e fumaça, e estas eram compostas por poeiras respiráveis e sílica. Tais exposições ocasionam sintomas vocais e sensações laríngeas e, consequentemente, alterações vocais. CONCLUSÃO: Sintomas vocais e sensações laríngeas podem estar relacionados a atividade profissional em que haja exposição a riscos físicos e/ou químicos.PURPOSE: To investigate vocal symptoms and laryngeal sensations among workers of an ethanol and sugar mill exposed to noise and/or chemical substances. METHODS: Participants were 289 workers of an ethanol and sugar mill distributed into five exposure groups (I - noise; II - noise, oil, grease

  5. Methotrexate Dosing Regimen for Plaque-type Psoriasis : A Systematic Review of the Use of Test-dose, Start-dose, Dosing Scheme, Dose Adjustments, Maximum Dose and Folic Acid Supplementation

    NARCIS (Netherlands)

    Menting, Stef P; Dekker, Paul M; Limpens, Jacqueline; Hooft, Lotty; Spuls, Phyllis I

    2016-01-01

    There is a range of methotrexate dosing regimens for psoriasis. This review summarizes the evidence for test-dose, start-dose, dosing scheme, dose adjustments, maximum dose and use of folic acid. A literature search for randomized controlled trials and guidelines was performed. Twenty-three

  6. Methotrexate Dosing Regimen for Plaque-type Psoriasis: A Systematic Review of the Use of Test-dose, Start-dose, Dosing Scheme, Dose Adjustments, Maximum Dose and Folic Acid Supplementation

    NARCIS (Netherlands)

    Menting, Stef P.; Dekker, Paul M.; Limpens, Jacqueline; Hooft, Lotty; Spuls, Phyllis I.

    2016-01-01

    There is a range of methotrexate dosing regimens for psoriasis. This review summarizes the evidence for test-dose, start-dose, dosing scheme, dose adjustments, maximum dose and use of folic acid. A literature search for randomized controlled trials and guidelines was performed. Twenty-three

  7. Avaliação e efeito da compactação do solo, devido à freqüência de tráfego, na produção de madeira de eucalipto Evaluation and effect of soil compaction due to traffic frequency on Eucalyptus wood production

    Directory of Open Access Journals (Sweden)

    Fernando Seixas

    2007-12-01

    Full Text Available A compactação do solo devido ao tráfego de máquinas de colheita de madeira, assim como a extensão da área impactada, constitui fator de preocupação, em virtude da possibilidade de efeitos prejudiciais para o crescimento da floresta. O objetivo deste trabalho foi avaliar os efeitos da freqüência de tráfego de um trator mais carreta na compactação do solo e na produtividade de um plantio de Eucalyptus grandis, no final da primeira rotação de sete anos. A compactação do solo, avaliada por meio da densidade e resistência à penetração, foi determinada para tratamentos com 1, 3, 5, 10 e 20 passadas do veículo carregado com 12,5 estéreos de madeira, com peso total de oito toneladas, além de uma testemunha sem a ocorrência de tráfego. Após as cinco primeiras passadas ocorreram cerca de 80% do adensamento total do solo, resultante das 20 passadas, sendo recomendado restringir o tráfego de veículos dentro do talhão na menor área possível, diminuindo-se a extensão de possíveis efeitos da compactação sobre o povoamento florestal. Contudo, nessa situação em particular a compactação do solo não prejudicou o crescimento das árvores em nenhum dos tratamentos avaliados.Soil compaction resulting from forestry machine traffic may reduce forest production. The objective of this study was to evaluate the influence of traffic frequency on soil compaction and Eucalyptus grandis forest productivity after a seven-year rotation. Soil bulk density and cone penetrometer resistance measurements were used as indicators to evaluate soil compaction resulting from tractor plus trailer traffic, a total of 8 tons load, after 1, 3, 5, 10, 20 vehicle passes and a control with no traffic. Around 80% of total soil compaction after 20 vehicle passes resulted after the first five vehicle passes, with no significant change after that. This indicates the necessity to restrict vehicle traffic to smaller areas in the forest, even with that area

  8. Liver transplantion in a patient with rapid onset parkinsonism-dementia complex induced by manganism secondary to liver failure Transplante hepático em um paciente com complexo parkinsonismo-demência rapidamente progressivo induzido por manganismo devido a insuficiência hepática

    Directory of Open Access Journals (Sweden)

    Giorgio Fabiani

    2007-09-01

    Full Text Available Bilateral and symmetric globus-pallidus hyperintensities are observed on T1-weighted MRI in most of the patients with chronic liver failure, due to manganese accumulation. We report a 53-year-old man, with rapid onset parkinsonism-dementia complex associated with accumulation of manganese in the brain, secondary to liver failure. A brain MRI was performed and a high signal on T1-weighted images was seen on globus-pallidus, as well as on T2-weighted images on the hemispheric white-matter. He was referred to a liver-transplantation. The patient passed away on the seventh postoperative day. Our findings support the concept of the toxic effects of manganese on the globus-pallidus. The treatment of this form of parkinsonism is controversial and liver-transplantation should not be considered as first line treatment but as an alternative one.Hiperintesidades simétricas e bilaterais dos gânglios da base são observadas em imagens de ressonância magnética encefálica (RM ponderadas em T1 na maioria dos pacientes com insuficiência hepática crônica devidas ao acúmulo de manganês. Nós relatamos o caso de um homem, com 53 anos de idade, com um complexo parkinsonismo-demência rapidamente progressivo associado com o acúmulo de manganês no cérebro, secundariamente a insuficiência hepática. Uma RM encefálica foi realizada e foram observadas imagens hiperintensas/hipersinal nas imagens ponderadas em T1 no globo pálido e, também, na substância branca dos hemisférios cerebrais ponderadas em T2. Devido à falta de resposta ao tratamento clinico optamos pelo transplante hepático. O paciente faleceu no 7º dia de PO. Nossos achados corroboram o conceito dos efeitos tóxicos do manganês nos gânglios da base/globo pálido. O tratamento desta forma de parkinsonismo é controverso e o transplante hepático não deverá ser considerada uma opção terapêutica de primeira linha, porém como um tratamento alternativo considerando-se os riscos

  9. Posição socioeconômica e duração do benefício por incapacidade devido a doenças musculoesqueléticas relacionadas ao trabalho Socioeconomic position and duration of disability benefit due to work-related musculoskeletal disorders

    Directory of Open Access Journals (Sweden)

    Norma Suely Souto Souza

    2012-02-01

    Full Text Available Neste estudo, estima-se o efeito da posição socioeconômica sobre a duração dos benefícios por incapacidade devido a doenças musculoesqueléticas. Dados de um inquérito conduzido pela Auditoria Regional do Instituto Nacional do Seguro Social, com todos os segurados que receberam benefício por incapacidade temporária por doenças musculoesqueléticas da região cervical e membros superiores, em 2008, juntamente com os registros administrativos, foram utilizados para formar uma coorte de 563 trabalhadores. Todos eram residentes em Salvador, Bahia. Entre os trabalhadores sindicalizados e com alta demanda psicossocial no trabalho, a posição socioeconômica se associava positivamente com a duração do benefício (RR = 1,89; IC95%: 1,25-2,87. Esses resultados correspondem ou a uma situação de iniquidade ou ao uso desnecessário do seguro pelos trabalhadores com posição socioeconômica alta. Investigações futuras que visem a elucidar as diferenças na utilização dos benefícios são necessárias para subsidiar a abordagem apropriada dessa questão pelos gestores do seguro social.This study estimated the effect of socioeconomic position on the duration of disability benefits due to musculoskeletal disorders affecting the neck and/or upper limbs. A cohort study including 563 insured workers from the city of Salvador, Bahia, Brazil, registered inthe General Social Security System and who received temporary disability benefits due to musculoskeletal disorders affecting the neck and/or upper limbs, , was performedin 2008 using data from the National Social Security Institute. The results show that among union member workers with high psychosocial demands at work, those with low socioeconomic status are almost twice as likely to receive benefit for a shorter period of time compared to those with a higher socioeconomic position (RR = 1.89; 95%CI: 1.25-2.87. These results reveal aninequitable situation or unnecessary use of insurance for

  10. In defence of collective dose

    International Nuclear Information System (INIS)

    Fairlie, I.; Sumner, D.

    2000-01-01

    Recent proposals for a new scheme of radiation protection leave little room for collective dose estimations. This article discusses the history and present use of collective doses for occupational, ALARA, EIS and other purposes with reference to practical industry papers and government reports. The linear no-threshold (LNT) hypothesis suggests that collective doses which consist of very small doses added together should be used. Moral and ethical questions are discussed, particularly the emphasis on individual doses to the exclusion of societal risks, uncertainty over effects into the distant future and hesitation over calculating collective detriments. It is concluded that for moral, practical and legal reasons, collective dose is a valid parameter which should continue to be used. (author)

  11. Fast in vivo volume dose reconstruction via reference dose perturbation

    International Nuclear Information System (INIS)

    Lu, Weiguo; Chen, Mingli; Mo, Xiaohu; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel

    2014-01-01

    Purpose: Accurate on-line reconstruction of in-vivo volume dose that accounts for both machine and patient discrepancy is not clinically available. We present a simple reference-dose-perturbation algorithm that reconstructs in-vivo volume dose fast and accurately. Methods: We modelled the volume dose as a function of the fluence map and density image. Machine (output variation, jaw/leaf position errors, etc.) and patient (setup error, weight loss, etc.) discrepancies between the plan and delivery were modelled as perturbation of the fluence map and density image, respectively. Delivered dose is modelled as perturbation of the reference dose due to change of the fluence map and density image. We used both simulated and clinical data to validate the algorithm. The planned dose was used as the reference. The reconstruction was perturbed from the reference and accounted for output-variations and the registered daily image. The reconstruction was compared with the ground truth via isodose lines and the Gamma Index. Results: For various plans and geometries, the volume doses were reconstructed in few seconds. The reconstruction generally matched well with the ground truth. For the 3%/3mm criteria, the Gamma pass rates were 98% for simulations and 95% for clinical data. The differences mainly appeared on the surface of the phantom/patient. Conclusions: A novel reference-dose-perturbation dose reconstruction model is presented. The model accounts for machine and patient discrepancy from planning. The algorithm is simple, fast, yet accurate, which makes online in-vivo 3D dose reconstruction clinically feasible.

  12. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  13. Organ Doses and Effective Doses in Pediatric Radiography: Patient-Dose Survey in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Kiljunen, T.; Tietaevaeinen, A.; Parviainen, T.; Viitala, A.; Kortesniemi, M. (Radiation Practices Regulation, Radiation and Nuclear Safety Authority, Helsinki (Finland))

    2009-01-15

    Background: Use of the effective dose in diagnostic radiology permits the radiation exposure of diverse diagnostic procedures to be quantified. Fundamental knowledge of patient doses enhances the implementation of the 'as low as reasonably achievable' (ALARA) principle. Purpose: To provide comparative information on pediatric examination protocols and patient doses in skull, sinus, chest, abdominal, and pelvic radiography examinations. Material and Methods: 24 Finnish hospitals were asked to register pediatric examination data, including patient information and examination parameters and specifications. The total number of examinations in the study was 1916 (1426 chest, 228 sinus, 96 abdominal, 94 skull, and 72 pelvic examinations). Entrance surface dose (ESD) and dose-area products (DAP) were calculated retrospectively or DAP meters were used. Organ doses and effective doses were determined using a Monte Carlo program (PCXMC). Results: There was considerable variation in examination protocols between different hospitals, indicating large variations in patient doses. Mean effective doses of different age groups ranged from 5 muSv to 14 muSv in skull and sinus examinations, from 25 muSv to 483 muSv in abdominal examinations, and from 6 muSv to 48 muSv in chest examinations. Conclusion: In chest and sinus examinations, the amount of data was extensive, allowing national pediatric diagnostic reference levels to be defined. Parameter selection in pediatric examination protocols should be harmonized in order to reduce patient doses and improve optimization

  14. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. (comps.)

    1992-06-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Battelle Pacific Northwest Laboratories under contract with the Centers for Disease Control. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demography, food consumption, and agriculture; environmental pathways and dose estimates.

  15. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Finch, S.M.; McMakin, A.H.

    1992-06-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Battelle Pacific Northwest Laboratories under contract with the Centers for Disease Control. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demography, food consumption, and agriculture; environmental pathways and dose estimates

  16. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  17. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Finch, S.M.; McMakin, A.H.

    1991-04-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from released to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demographics, agriculture, food habits; and, environmental pathways and dose estimates

  18. Prenatal radiation doses from radiopharmaceuticals

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.M.; Di Trano, J.L.

    1998-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author) [es

  19. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  20. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  1. Aplicação de programa educativo multidisciplinar em gestações de alto risco devido a doenças endócrinas Application of multidisciplinary educational program in high-risk pregnancies due to endocrine diseases

    Directory of Open Access Journals (Sweden)

    Alina Coutinho Rodrigues Feitosa

    2010-10-01

    Full Text Available OBJETIVO: avaliar a aplicação de um programa de intervenção multidisciplinar educativo em mulheres com gestação de alto risco devido a doenças endócrinas. MÉTODOS: avaliamos retrospectivamente a aplicação de um programa educativo multidisciplinar em 185 gestantes com doenças endócrinas referenciadas para uma maternidade especializada em gestação de alto risco. As gestantes receberam atenção pré-natal multidisciplinar por times compostos por endocrinologistas, obstetras, ultrassonografistas, enfermeiras e nutricionistas. Informações orais e escritas sobre hábitos saudáveis, cuidados com diabetes, uso de adoçantes artificiais e exercícios na gestação foram passadas na primeira consulta endocrinológica. Plano nutricional individualizado foi feito em primeira visita à nutricionista. Nas reavaliações mensais com nutricionista e quinzenais com endocrinologista, as informações sobre mudanças saudáveis no estilo de vida eram reforçadas e o peso registrado. O grau de aderência à dieta e atividade física foi autorreferido. Comparou-se o peso semanal antes e após a intervenção multidisciplinar, peso fetal ao nascimento, taxa de macrossomia e baixo peso, e a frequência de parto cesário nas quatro categorias de índice de massa corpórea (IMC pré-gestacional (30 kg/m². RESULTADOS: a principal patologia de encaminhamento foi o diabetes (84,9%. Um terço das gestantes (31,2% era composto por portadoras de sobrepeso e 42,5% tinham obesidade pré-gestacional. A maior parte das gestantes foi vista pela primeira vez pela equipe multidisciplinar no terceiro trimestre (64,1%, e 50,5% delas excederam o ganho de peso recomendado para toda a gestação à primeira avaliação. Gestantes obesas excederam o ganho de peso recomendado em 62,5% dos casos. Após a intervenção multidisciplinar, o percentual de gestantes que excedeu o ganho de peso semanal recomendado reduziu em todas as categorias de IMC pré-gestacional (IMCPG

  2. The Effect of Low‑Dose Ketamine (Preemptive Dose) on ...

    African Journals Online (AJOL)

    The Effect of Low‑Dose Ketamine (Preemptive Dose) on Postcesarean. Section Pain Relief. Forozan Milani, Katayoun Haryalchi, Seyedeh Hajar Sharami, Roya Faraji, Maryam Asgharnia, Fatemeh Salamat1,. Seyedeh Saeedeh Hashemi. Reproductive Health Research Center, Alzahra Hospital, School of Medicine, 1Guilan ...

  3. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional radiolo- gists, radiographers and nurses ...

  4. Low doses effects and gamma radiations low dose rates

    International Nuclear Information System (INIS)

    Averbeck, D.

    1999-01-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  5. Reduced medical and occupational exposures by optimizing working procedures in fluoroscopy equipment in the University Hospital of Santa Maria (RS); Reducao de exposicao medicas e ocupacionais pela otimizacao de procedimentos de trabalho em equipamento de fluoroscopia no Hospital Universitario de Santa Maria (RS)

    Energy Technology Data Exchange (ETDEWEB)

    Weis, Guilherme L.; Claus, Thiago V.; Baumhardt, Tadeu, E-mail: glweis@gmail.com [Hospital Universitario de Santa Maria, RS (Brazil); Shuch, Luiz A. [Universidade Federal de Santa Maria (UFSM), RS (Brazil). Dept. de Fisica

    2013-08-15

    This work seeks to reduce medical (patient) and occupational (workers) exposure by standardizing resources available in fluoroscopy equipment used in interventional procedures. Such procedures use transportable surgical arch type fluoroscopy equipment, with applications in orthopedics, angiography and pacemaker implantation. Improper use of these devices generates excessive radiation doses in both patients and the medical staff. It is observed that the equipment after being connected to the grid, is pre-selected to work in continuous fluoroscopy and no additional filtration, producing higher doses of radiation. For specific applications, changes in protocols should be undertaken according to medical indication. This work used a fluoroscopy equipment Shimadzu Active Opescope two radiation monitoring equipment, brand Radcal, models 9010 and 9015, two ionization chambers, of 60 cc and 180 cc and a low contrast phantom and a catheter, information that simulate the human body. Incidences were performed by changing the conditions of exposure as frame rates (fps - frames per second) and additional filtration. For each composition parameters was generated and filed an image, with the extent of their respective doses. These images were evaluated by radiologists. In more extreme cases we obtained a reduction of a factor 25 in occupational exposure (medical personnel) using the pulsed with the greatest 2 fps additional filter (0.3 mm Cu) compared to continuous system without any additional filtration. In medical exposure (of patients), decreased by a factor 39, the same conditions described above. With these arguments it is justified the optimization and standardization of the equipment used in fluoroscopy, which besides providing a dose reduction the patient and the medical personnel, increases the life of the X-ray tube while maintaining the quality of medical diagnosis. (author)

  6. Pathogenic effects of low dose irradiation: dose-effect relationships

    International Nuclear Information System (INIS)

    Masse, R.

    2002-01-01

    There is no evidence of pathogenic effects in human groups exposed to less than 100 mSv at low dose-rate. The attributed effects are therefore the result of extrapolations from higher doses. The validity of such extrapolations is discussed from the point of view of epidemiology as well as cellular and molecular biology. The Chernobyl accident resulted in large excess of thyroid cancers in children; it also raised the point that some actual sanitary effects among distressed populations might be a direct consequence of low doses. Studies under the control of UN have not confirmed this point identifying no dose-effect relationship and 'severe socio-economic and psychological pressures... poverty, poor diet and living conditions, and lifestyle factors' as the main cause for depressed health. Some hypothesis are considered for explaining the dose-dependence and high prevalence of non-cancer causes of death among human groups exposed to more than 300 mSv. (author)

  7. Dose calculation of anticancer drugs

    NARCIS (Netherlands)

    Gao, Bo; Klumpen, Heinz-Josef; Gurney, Howard

    2008-01-01

    BACKGROUND: Anticancer drugs are characterized by a narrow therapeutic window and significant inter-patient variability in therapeutic and toxic effects. Current body surface area (BSA)-based dosing fails to standardize systemic anticancer drug exposure and other alternative dosing strategies also

  8. Time and dose in carcinogenesis

    International Nuclear Information System (INIS)

    Mayneord, W.V.; Clarke, R.H.

    1978-05-01

    Previous work on the implications of different forms of dose response relationships is extended to include time as a variable, not only in time of irradiation but also in the time of appearance of effects following irradiation. The forms of relationships for time distribution of tumours revealed experimentally for both radiation and chemical carcinogens are first considered. It appears that much data may be correlated in terms of a log-normal distribution of tumour yield following the insult. Further, it is noted, that there is evidence that the median time of tumour appearance may be a function of total dose received or even of dose rate for protracted exposure. Using numerical values of these parameters derived from the biological literature speculative studies have been made of the effects on dose response relationships of using a time distribution of tumour yield, considering both uniform irradiation and point sources. In addition the effects of using dose rate rather than dose to define the log-normal distribution to tumour appearance have been investigated. It is assumed that biological response is directly proportional to dose but that effect is distributed in time. From this linear assumption the appearance of non-linear dose response relationships and apparent thresholds are continually seen. Finally, both the importance of attempting analyses of biological data in terms of stochastic concepts and the need for biological data to test our hypotheses is emphasised. (author)

  9. EPA's Benchmark Dose Modeling Software

    Science.gov (United States)

    The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...

  10. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M. (comp.)

    1990-09-01

    This monthly report summarizes the technical progress and project status for the Hanford Environmental Dose Reconstruction (HEDR) Project being conducted at the Pacific Northwest Laboratory (PNL) under the direction of a Technical Steering Panel (TSP). The TSP is composed of experts in numerous technical fields related to this project and represents the interests of the public. The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms, environmental transport, environmental monitoring data, demographics, agriculture, food habits, environmental pathways and dose estimates. 3 figs.

  11. Evolution of radon dose evaluation

    Directory of Open Access Journals (Sweden)

    Fujimoto Kenzo

    2004-01-01

    Full Text Available The historical change of radon dose evaluation is reviewed based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR reports. Since 1955, radon has been recognized as one of the important sources of exposure of the general public. However, it was not really understood that radon is the largest dose contributor until 1977 when a new concept of effective dose equivalent was introduced by International Commission on Radiological Protection. In 1982, the dose concept was also adapted by UNSCEAR and evaluated per caput dose from natural radiation. Many researches have been carried out since then. However, lots of questions have remained open in radon problems, such as the radiation weighting factor of 20 for alpha rays and the large discrepancy of risk estimation among dosimetric and epidemiological approaches.

  12. Labour cost of radiation dose

    International Nuclear Information System (INIS)

    Cook, A.; Lockett, L.E.

    1978-01-01

    In order to optimise capital expenditure on measures to protect workers against radiation it would be useful to have a means to measure radiation dose in money terms. Because labour has to be employed to perform radiation work there must be some relationship between the wages paid and the doses received. Where the next increment of radiation dose requires additional labour to be recruited the cost will at least equal the cost of the extra labour employed. This paper examines some of the factors which affect the variability of the labour cost of radiation dose and notes that for 'in-plant' exposures the current cost per rem appears to be significantly higher than values quoted in ICRP Publication 22. An example is given showing how this concept may be used to determine the capital it is worth spending on installed plant to prevent regular increments of radiation dose to workers. (author)

  13. Dose optimisation in computed radiography

    International Nuclear Information System (INIS)

    Schreiner-Karoussou, A.

    2005-01-01

    After the installation of computed radiography (CR) systems in three hospitals in Luxembourg a patient dose survey was carried out for three radiographic examinations, thorax, pelvis and lumbar spine. It was found that the patient doses had changed in comparison with the patient doses measured for conventional radiography in the same three hospitals. A close collaboration between the manufacturers of the X-ray installations, the CR imaging systems and the medical physicists led to the discovery that the speed class with which each radiographic examination was to be performed, had been ignored, during installation of the digital imaging systems. A number of procedures were carried out in order to calibrate and program the X-ray installations in conjunction with the CR systems. Following this optimisation procedure, a new patient dose survey was carried out for the three radiographic examinations. It was found that patient doses for the three hospitals were reduced. (authors)

  14. Bone and marrow dose modeling

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    2004-01-01

    Nuclear medicine therapy is being used increasingly in the treatment of cancer (thyroid, leukemia/lymphoma with RIT, primary and secondary bone malignancies, and neuroblastomas). In all cases it is marrow toxicity that limits the amount of treatment that can be administered safely. Marrow dose calculations are more difficult than for many major organs because of the intricate association of bone and soft tissue elements. In RIT, there appears to be no consensus on how to calculate that dose accurately, or of individual patients ability to tolerate planned therapy. Available dose models are designed after an idealized average, healthy individual. Patient-specific methods are applied in evaluation of biokinetic data, and need to be developed for treatment of the physical data (dose conversion factors) as well: age, prior patient therapy, disease status. Contributors to marrow dose: electrons and photons

  15. Establishment Of Dose Correlation During Dose Mapping On Medical Devices

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    This paper explains the work done during product dose mapping in order to get the correlation between doses at MINTec-Sinagama plant. Product used was medical devices in aluminium tubes packaged in cardboard kegs packaging with average weight of 12 kg per carton. 12 cartons were loaded in every one tote to give 0.2 g/ cm 3 of density. Ceric cerous dosimeters were placed at specific locations as indicated in SP14: Product Dose Mapping, QMS of MINTec-Sinagama around three planes. Three processes were made at different days as a three replicates to show the reproducibility of measurements. (author)

  16. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  17. Patient dose in neonatal units

    International Nuclear Information System (INIS)

    Smans, K.; Struelens, L.; Smet, M.; Bosmans, H.; Vanhavere, F.

    2008-01-01

    Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Hence, knowledge of the patient dose is necessary to justify the exposures. A study to assess the patient doses was started at the neonatal intensive care unit (NICU) of the Univ. Hospital in Leuven. Between September 2004 and September 2005, prematurely born babies underwent on average 10 X-ray examinations in the NICU. In this sample, the maximum was 78 X-ray examinations. For chest radiographs, the median entrance skin dose was 34 μGy and the median dose area product was 7.1 mGy.cm 2 . By means of conversion coefficients, the measured values were converted to organ doses. Organ doses were calculated for three different weight classes: extremely low birth weight infants ( 2500 g). The doses to the lungs for a single chest radiograph for infants with extremely low birth weights, low birth weights and normal birth weights were 24, 25 and 32 μGy, respectively. (authors)

  18. CT doses in cylindrical phantoms

    International Nuclear Information System (INIS)

    Atherton, J.V.; Huda, W.

    1995-01-01

    A single CT scan of thickness T in a cylindrical phantom produces a three-dimensional dose distribution, which depends primarily on the photon energy spectrum, the x-ray beam shaping filter and the size and composition of the irradiated phantom. Monte Carlo simulations employing monoenergetic photons were employed to investigate the effect of each of these factors on phantom dose distributions. The fractional energies scattered, imparted and transmitted through the CT phantom were calculated. A dose index (D(r)), which is a function of phantom radius r, was computed. Phantom materials investigated included lung, fat, water, soft tissue, acrylic and bone with calculations performed for head (160 mm diameter) and body (320 mm diameter) phantoms. All dose and energy imparted data generated for CT phantoms were normalized using an 'in air' dose (D air ), which is defined as the axial dose (in acrylic) at the isocentre in the absence of any phantom. Results obtained show how CT parameters impact on doses in cylindrical phantoms. These dosimetry data are likely to be useful to estimate energy imparted to phantoms (and patients) undergoing CT examinations. (author)

  19. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  20. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  1. Are low radiation doses Dangerous?

    International Nuclear Information System (INIS)

    Garcia Lima, O.; Cornejo, N.

    1996-01-01

    In the last few years the answers to this questions has been affirmative as well as negative from a radiation protection point of view low doses of ionizing radiation potentially constitute an agent causing stochasting effects. A lineal relation without threshold is assumed between dose and probability of occurrence of these effects . Arguments against the danger of probability of occurrence of these effects. Arguments again the danger of low dose radiation are reflected in concepts such as Hormesis and adaptive response, which are phenomena that being studied at present

  2. Savannah River Site dose control

    International Nuclear Information System (INIS)

    Smith, L.S.

    1992-01-01

    Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits

  3. Patient dose in interventional radiology

    International Nuclear Information System (INIS)

    Fernandez Bordes, M.; Berenguer, R.; Gomez, P.; Bejar, M.J.; Gonzalez, S.

    2001-01-01

    This paper presents the estimation of dose-area product (DAP) received by 128 patients during different interventional radiological procedures in the Hospital Universitario de Salamanca, analyzing the differences between procedures classified as either vascular, non vascular, diagnostic or therapeutic. These differences can be assessed and reference dose levels can be established as a function of the variation of those parameters. Comparisons between dose-area product values obtained from this study are made with the data from nine other patient dose surveys, although explanations for some of the differences could not be obtained in some cases. The reference values in these procedures in our centre are very high due to a great number of images, so the clinical protocol should be changed to avoid this problem. (author)

  4. Doses from Medical Radiation Sources

    Science.gov (United States)

    ... York Northern California Northern Ohio Rio Grande Savannah River State of Texas Southern California Susquehanna Valley Virginia ... patient's metabolism), and other issues. Typical Doses from Diagnostic Radiology Exams As noted above, the tables below ...

  5. Dose from drinking water Finland

    International Nuclear Information System (INIS)

    Maekelaeinen, Ilona; Salonen, Laina; Huikuri, Pia; Arvela, Hannu

    1999-01-01

    The dose from drinking water originates almost totally from naturally occurring radionuclides in the uranium-238 series, the most important nuclide being radon-222. Second comes lead-210, and third polonium-210. The mean age-group-weighted dose received by ingestion of drinking water is 0.14 mSv per year. More than half of the total cumulative dose of 750 manSv is received by the users of private wells, forming 13% of the population. The most exposed group comprises the users of wells drilled in bedrock, who receive 320 manSv while comprising only 4% of the population. The calculated number of annual cancer incidences due to drinking water is very sensitive to the dose-conversion factors of ingested radon used, as well as to the estimated lung cancer incidences caused by radon released from water into indoor air. (au)

  6. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    McMakin, A.H.; Cannon, S.D.; Finch, S.M.

    1992-07-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source terms, environmental transport, environmental monitoring data, demography, food consumption, and agriculture, and environmental pathways and dose estimates. Progress is discussed

  7. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    McMakin, A.H.; Cannon, S.D.; Finch, S.M. (comps.)

    1992-07-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source terms, environmental transport, environmental monitoring data, demography, food consumption, and agriculture, and environmental pathways and dose estimates. Progress is discussed.

  8. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. (comps.)

    1991-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon and Washington, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on human (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data; Demographics, Agriculture, Food Habits and; Environmental Pathways and Dose Estimates.

  9. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  10. Gamma Radiation Doses In Sweden

    International Nuclear Information System (INIS)

    Almgren, Sara; Isaksson, Mats; Barregaard, Lars

    2008-01-01

    Gamma dose rate measurements were performed in one urban and one rural area using thermoluminescence dosimeters (TLD) worn by 46 participants and placed in their dwellings. The personal effective dose rates were 0.096±0.019(1 SD) and 0.092±0.016(1 SD)μSv/h in the urban and rural area, respectively. The corresponding dose rates in the dwellings were 0.11±0.042(1 SD) and 0.091±0.026(1 SD)μSv/h. However, the differences between the areas were not significant. The values were higher in buildings made of concrete than of wood and higher in apartments than in detached houses. Also, 222 Rn measurements were performed in each dwelling, which showed no correlation with the gamma dose rates in the dwellings

  11. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  12. Dose Distribution of Gamma Irradiators

    International Nuclear Information System (INIS)

    Park, Seung Woo; Shin, Sang Hun; Son, Ki Hong; Lee, Chang Yeol; Kim, Kum Bae; Jung, Hai Jo; Ji, Young Hoon

    2010-01-01

    Gamma irradiator using Cs-137 have been widely utilized to the irradiation of cell, blood, and animal, and the dose measurement and education. The Gamma cell 3000 Elan (Nordion International, Kanata, Ontario, Canada) irradiator was installed in 2003 with Cs-137 and dose rate of 3.2 Gy/min. And the BioBeam 8000 (Gamma-Service Medical GmbH, Leipzig, Germany) irradiator was installed in 2008 with Cs-137 and dose rate of 3.5 Gy/min. Our purpose was to evaluate the practical dosimetric problems associated with inhomogeneous dose distribution within the irradiated volume in open air state using glass dosimeter and Gafchromic EBT film dosimeter for routine Gamma irradiator dosimetry applications at the KIRAMS and the measurements were compared with each other. In addition, an user guideline for useful utilization of the device based on practical dosimetry will be prepared. The measurement results of uniformity of delivered dose within the device showed variation more than 14% between middle point and the lowest position at central axis. Therefore, to maintain dose variation within 10%, the criteria of useful dose distribution, for research radiation effects, the irradiated specimen located at central axis of the container should be placed within 30 mm from top and bottom surface, respectively. In addition, for measurements using the film, the variations of dose distribution were more then 50% for the case of less than 10 second irradiation, mostly within 20% for the case of more than 20 second irradiation, respectively. Therefore, the irradiation experiments using the BioBeam 8000 irradiator are recommended to be used for specimen required at least more than 20 second irradiation time.

  13. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  14. The dose makes the medicine.

    Science.gov (United States)

    Stumpf, Walter E

    2006-06-01

    Dose and time considerations in the development and use of a drug are important for assessing actions and side effects, as well as predictions of safety and toxicity. This article deals with epistemological aspects of dose selection by probing into the linguistic and cultural roots for the measure of medicine mediated by the medical doctor. Because toxicity is related to dose, historic and recent views suggest that less can be more. At low, medium and high dose levels, effects can differ not only quantitatively but also qualitatively. Dose-related target activation and recognition of enantiodromic thresholds between beneficial and toxic effects require elucidation of underlying events. Such studies, including hormesis and microdosing, call for extended ADME procedures with high-resolution methods in addition to the current low-resolution approaches. Improved information of drug logistics and target pharmacokinetics enables effective drug selection, dose determination and prediction. It also allows considerations of systems biology [i.e. integral (gestalt) pharmacology] exemplified by the drug homunculus, as in the case of vitamin D, that might lead to new paradigms and drug design.

  15. Weldon Spring historical dose estimate

    Energy Technology Data Exchange (ETDEWEB)

    Meshkov, N.; Benioff, P.; Wang, J.; Yuan, Y.

    1986-07-01

    This study was conducted to determine the estimated radiation doses that individuals in five nearby population groups and the general population in the surrounding area may have received as a consequence of activities at a uranium processing plant in Weldon Spring, Missouri. The study is retrospective and encompasses plant operations (1957-1966), cleanup (1967-1969), and maintenance (1969-1982). The dose estimates for members of the nearby population groups are as follows. Of the three periods considered, the largest doses to the general population in the surrounding area would have occurred during the plant operations period (1957-1966). Dose estimates for the cleanup (1967-1969) and maintenance (1969-1982) periods are negligible in comparison. Based on the monitoring data, if there was a person residing continually in a dwelling 1.2 km (0.75 mi) north of the plant, this person is estimated to have received an average of about 96 mrem/yr (ranging from 50 to 160 mrem/yr) above background during plant operations, whereas the dose to a nearby resident during later years is estimated to have been about 0.4 mrem/yr during cleanup and about 0.2 mrem/yr during the maintenance period. These values may be compared with the background dose in Missouri of 120 mrem/yr.

  16. Weldon Spring historical dose estimate

    International Nuclear Information System (INIS)

    Meshkov, N.; Benioff, P.; Wang, J.; Yuan, Y.

    1986-07-01

    This study was conducted to determine the estimated radiation doses that individuals in five nearby population groups and the general population in the surrounding area may have received as a consequence of activities at a uranium processing plant in Weldon Spring, Missouri. The study is retrospective and encompasses plant operations (1957-1966), cleanup (1967-1969), and maintenance (1969-1982). The dose estimates for members of the nearby population groups are as follows. Of the three periods considered, the largest doses to the general population in the surrounding area would have occurred during the plant operations period (1957-1966). Dose estimates for the cleanup (1967-1969) and maintenance (1969-1982) periods are negligible in comparison. Based on the monitoring data, if there was a person residing continually in a dwelling 1.2 km (0.75 mi) north of the plant, this person is estimated to have received an average of about 96 mrem/yr (ranging from 50 to 160 mrem/yr) above background during plant operations, whereas the dose to a nearby resident during later years is estimated to have been about 0.4 mrem/yr during cleanup and about 0.2 mrem/yr during the maintenance period. These values may be compared with the background dose in Missouri of 120 mrem/yr

  17. Risk after low radiation doses

    International Nuclear Information System (INIS)

    Streffer, C.

    1989-01-01

    The high-level data measured in radiation doses need to be extrapolated to lower dose ranges in order to be able to state the risk of leukaemia and cancer in low radiation doses. The assumption is that there is no threshold dose although there has been no scientific verification for this yet. Conceptual considerations concerning the radiation action mechanisms suggest that a threshold dose does not exist. The assumption is that leukaemia and cancer are induced by the fact that individual transformed and malignant cells possess a certain though low potential to cause a malignant disease (leukaemia or cancer). It is assumed that radiation exposure produces damage to the genetic material of the cell which results in a malignant transformation. The number of these events is greatly reduced by a highly effective repair mechanism. However, these repair processes at the DNA are not complete or may even result in a misrepair; even low radiation doses (less than 10 mSv, 1 rem) apparently may trigger such cellular effects (transformation). (orig./HSCH) [de

  18. Technical basis for dose reconstruction

    International Nuclear Information System (INIS)

    Anspaugh, L.R.

    1996-01-01

    The purpose of this paper is to consider two general topics: technical considerations of why dose-reconstruction studies should or should not be performed and methods of dose reconstruction. The first topic is of general and growing interest as the number of dose-reconstruction studies increases, and one asks the question whether it is necessary to perform a dose reconstruction for virtually every site at which, for example, the Department of Energy (DOE) has operated a nuclear-related facility. And there is the broader question of how one might logically draw the line at performing or not performing dose-reconstruction (radiological and chemical) studies for virtually every industrial complex in the entire country. The second question is also of general interest. There is no single correct way to perform a dose-reconstruction study, and it is important not to follow blindly a single method to the point that cheaper, faster, more accurate, and more transparent methods might not be developed and applied

  19. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  20. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  1. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  2. Low-dose dental CT

    International Nuclear Information System (INIS)

    Rustemeyer, P.; Eich, H.T.; John-Mikolajewski, V.; Mueller, R.D.

    1999-01-01

    Purpose: The intention of this study was to reduce patient dose during dental CT in the planning for osseointegrated implants. Methods and Materials: Dental CTs were performed with a spiral CT (Somatom Plus 4, Siemens) and a dental software package. Use of the usual dental CT technique (120 kVp; 165 mA, 1 s rotation time, 165 mAs; pitch factor 1) was compared with a new protocol (120 kVp; 50 mA; 0.7 s rotation time; 35 mAs; pitch factor 2) which delivered the best image quality at the lowest possible radiation dose, as tested in a preceding study. Image quality was analysed using a human anatomic head preparation. Four radiologists analysed the images independently. A Wilcoxon rank pair-test was used for statistic evaluation. The doses to the thyroid gland, the active bone marrow, the salivary glands, and the eye lens were determined in a tissue-equivalent phantom (Alderson-Rando Phantom) with lithium fluoride thermoluminescent dosimeters at the appropriate locations. Results: By mAs reduction from 165 to 35 and using a pitch factor of 2, the radiation dose could be reduced by a factor of nine (max.) (e.g., the bone marrow dose could be reduced from 23.6 mSv to 2.9 mSv, eye lens from 0.5 mSv to 0.3 mSv, thyroid gland from 2.5 mSv to 0.5 mSv, parotid glands from 2.3 mSv to 0.4 mSv). The dose reduction did not lead to an actual loss of image quality or diagnostic information. Conclusion: A considerable dose reduction without loss of diagnostic information is achievable in dental CT. Dosereducing examination protocols like the one presented may further expand the use of preoperative dental CT. (orig.) [de

  3. Medical exposure and effective dose

    International Nuclear Information System (INIS)

    Maruyama, Takashi

    1995-01-01

    The frequency of radiological diagnosis in Japan and individual population effective dose are reported. Questionnaire on radiological practice was delivered to selected medical facilities. The total number of X-ray diagnosis performed in 1991 was 180,000,000, being age-dependent in both men and women. The chest was the most common site to be examined. The number of X-ray films per examination was the highest for the stomach. The spread of ultrasound has decreased radiological practice in the obstetric field (approximately one sixth between 1979 and 1986). There was an 8-fold increase in the number of X-ray CT as of 1989 during the past decade. The total number of CT scanning in 1989 reached nearly 14,850,000 (about 16 times as much as that of 1979). The number of stomach X-ray screening increased to 7,800,000 which is twice as much as that in 1975. In the dental field, panoramic method brought about a 7-fold increase between 1974 and 1985. The frequency of nuclear medicine diagnosis has slightly increased, reaching 1,400,000 cases in 1992, and 99m Tc was the most common nuclide. The total population effective dose of radiography and fluoroscopy was 179,000 mSv. The highest effective dose was associated with gastric X-ray. The effective dose equivalent per diagnosis was estimated to be 1.02 mSv (the total population/total number of radiological diagnosis). The population effective dose per person was 2.3 mSv (population effective dose equivalent/national population), which was equal to the world average of yearly effective dose equivalent of natural radiation. (S.Y.)

  4. Medical exposure and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Takashi [Association of Radiation Effects, Chiba (Japan)

    1995-09-01

    The frequency of radiological diagnosis in Japan and individual population effective dose are reported. Questionnaire on radiological practice was delivered to selected medical facilities. The total number of X-ray diagnosis performed in 1991 was 180,000,000, being age-dependent in both men and women. The chest was the most common site to be examined. The number of X-ray films per examination was the highest for the stomach. The spread of ultrasound has decreased radiological practice in the obstetric field (approximately one sixth between 1979 and 1986). There was an 8-fold increase in the number of X-ray CT as of 1989 during the past decade. The total number of CT scanning in 1989 reached nearly 14,850,000 (about 16 times as much as that of 1979). The number of stomach X-ray screening increased to 7,800,000 which is twice as much as that in 1975. In the dental field, panoramic method brought about a 7-fold increase between 1974 and 1985. The frequency of nuclear medicine diagnosis has slightly increased, reaching 1,400,000 cases in 1992, and {sup 99m}Tc was the most common nuclide. The total population effective dose of radiography and fluoroscopy was 179,000 mSv. The highest effective dose was associated with gastric X-ray. The effective dose equivalent per diagnosis was estimated to be 1.02 mSv (the total population/total number of radiological diagnosis). The population effective dose per person was 2.3 mSv (population effective dose equivalent/national population), which was equal to the world average of yearly effective dose equivalent of natural radiation. (S.Y.).

  5. Radiological dose assessment for vault storage concepts

    Energy Technology Data Exchange (ETDEWEB)

    Richard, R.F.

    1997-02-25

    This radiological dose assessment presents neutron and photon dose rates in support of project W-460. Dose rates are provided for a single 3013 container, the ``infloor`` storage vault concept, and the ``cubicle`` storage vault concept.

  6. Patient and staff doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Bor, D.; Cekirge, S.; Tuerkay, T.; Turan, O.; Guelay, M.; Oenal, E.; Cil, B.

    2005-01-01

    Radiation doses for interventional examinations are generally high and therefore necessitate dose monitoring for patients and staff. Relating the staff dose to a patient dose index, such as dose-area product (DAP), could be quite useful for dose comparisons. In this study, DAP and skin doses of 57 patients, who underwent neuro-interventional examinations, were measured simultaneously with staff doses. Although skin doses were comparable with the literature data, higher DAP values of 215 and 188.6 Gy cm 2 were measured for the therapeutical cerebral and carotid examinations, respectively, owing to the use of biplane system and complexity of the procedure. Mean staff doses for eye, finger and thyroid were measured as 80.6, 77.6 and 28.8 μGy per procedure. The mean effective dose per procedure for the radiologists was 32 μSv. In order to allow better comparisons to be made, DAP normalised doses were also presented. (authors)

  7. Influence of dose calculation algorithms on the predicted dose distribution and NTCP values for NSCLC patients

    DEFF Research Database (Denmark)

    Nielsen, Tine B; Wieslander, Elinore; Fogliata, Antonella

    2011-01-01

    To investigate differences in calculated doses and normal tissue complication probability (NTCP) values between different dose algorithms.......To investigate differences in calculated doses and normal tissue complication probability (NTCP) values between different dose algorithms....

  8. Notes on the effect of dose uncertainty

    International Nuclear Information System (INIS)

    Morris, M.D.

    1987-01-01

    The apparent dose-response relationship between amount of exposure to acute radiation and level of mortality in humans is affected by uncertainties in the dose values. It is apparent that one of the greatest concerns regarding the human data from Hiroshima and Nagasaki is the unexpectedly shallow slope of the dose response curve. This may be partially explained by uncertainty in the dose estimates. Some potential effects of dose uncertainty on the apparent dose-response relationship are demonstrated

  9. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S. M.; McMakin, A. H.

    1991-09-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation dose that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into five technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (i.e., dose estimates). The Source Terms Task develops estimates of radioactive emissions from Hanford facilities since 1944. The Environmental Transport Task reconstructs the movements of radioactive particles from the areas of release to populations. The Environmental Monitoring Data Task assemblies, evaluates and reports historical environmental monitoring data. The Demographics, Agriculture and Food Habits Task develops the data needed to identify the populations that could have been affected by the releases. The Environmental Pathways and Dose Estimates Task used the information derived from the other Tasks to estimate the radiation doses individuals could have received from Hanford radiation. This document lists the progress on this project as of September 1991. 3 figs., 2 tabs.

  10. Parameterization of solar flare dose

    International Nuclear Information System (INIS)

    Lamarche, A.H.; Poston, J.W.

    1996-01-01

    A critical aspect of missions to the moon or Mars will be the safety and health of the crew. Radiation in space is a hazard for astronauts, especially high-energy radiation following certain types of solar flares. A solar flare event can be very dangerous if astronauts are not adequately shielded because flares can deliver a very high dose in a short period of time. The goal of this research was to parameterize solar flare dose as a function of time to see if it was possible to predict solar flare occurrence, thus providing a warning time. This would allow astronauts to take corrective action and avoid receiving a dose greater than the recommended limit set by the National Council on Radiation Protection and Measurements (NCRP)

  11. Dose reconstruction using mobile phones

    International Nuclear Information System (INIS)

    Beerten, K.; Reekmans, F.; Schroeyers, W.; Lievens, L.; Vanhavere, F.

    2011-01-01

    Electronic components inside mobile phones are regarded as useful tools for accident and retrospective dosimetry using optically stimulated luminescence (OSL) and thermoluminescence. Components inside the devices with suitable properties for luminescence dosimetry include, amongst others, ceramic substrates in resistors, capacitors, transistors and antenna switches. Checking the performance of such devices in dosimetric experiments is a crucial step towards developing a reliable dosimetry system for emergency situations using personal belongings. Here, the results of dose assessment experiments using irradiated mobile phones are reported. It will be shown that simple regenerative dose estimates, derived from various types of components removed from different mobile phone models, are consistent with the given dose, after applying an average fading correction factor. (authors)

  12. Consultative exercise on dose assessments.

    Science.gov (United States)

    Bridges, B A; Parker, T; Simmonds, J R; Sumner, D

    2001-06-01

    A summary is given of a meeting held at Sussex University, UK, in October 2000, which allowed the exchange of ideas on methods of assessment of dose to the public arising from potential authorised radioactive discharges from nuclear sites in the UK. Representatives of groups with an interest in dose assessments were invited, and hence the meeting was called the Consultative Exercise on Dose Assessments (CEDA). Although initiated and funded by the Food Standards Agency, its organisation, and the writing of the report, were overseen by an independent Chairman and Steering Group. The report contains recommendations for improvement in co-ordination between different agencies involved in assessments, on method development and on the presentation of data on assessments. These have been prepared by the Steering Group, and will be taken forward by the Food Standards Agency and other agencies in the UK. The recommendations are included in this memorandum.

  13. Radiation Dose from Reentrant Electrons

    Science.gov (United States)

    Badhwar, G.D.; Cleghorn, T. E.; Watts, J.

    2003-01-01

    In estimating the crew exposures during an EVA, the contribution of reentrant electrons has always been neglected. Although the flux of these electrons is small compared to the flux of trapped electrons, their energy spectrum extends to several GeV compared to about 7 MeV for trapped electrons. This is also true of splash electrons. Using the measured reentrant electron energy spectra, it is shown that the dose contribution of these electrons to the blood forming organs (BFO) is more than 10 times greater than that from the trapped electrons. The calculations also show that the dose-depth response is a very slowly changing function of depth, and thus adding reasonable amounts of additional shielding would not significantly lower the dose to BFO.

  14. The Effect of Low‑Dose Ketamine (Preemptive Dose) on ...

    African Journals Online (AJOL)

    Average dosage of diclofenac suppository and mean time for taking the first dosage of opioids have not statistical difference too (respectively; P = 0.76, P = 0.87). Average dose of pethidine was lesser than placebo statistically. It means, the case group did not take pethidine but this amount was 6 (20%) in the control one (P ...

  15. A comparison of quantum limited dose and noise equivalent dose

    Science.gov (United States)

    Job, Isaias D.; Boyce, Sarah J.; Petrillo, Michael J.; Zhou, Kungang

    2016-03-01

    Quantum-limited-dose (QLD) and noise-equivalent-dose (NED) are performance metrics often used interchangeably. Although the metrics are related, they are not equivalent unless the treatment of electronic noise is carefully considered. These metrics are increasingly important to properly characterize the low-dose performance of flat panel detectors (FPDs). A system can be said to be quantum-limited when the Signal-to-noise-ratio (SNR) is proportional to the square-root of x-ray exposure. Recent experiments utilizing three methods to determine the quantum-limited dose range yielded inconsistent results. To investigate the deviation in results, generalized analytical equations are developed to model the image processing and analysis of each method. We test the generalized expression for both radiographic and fluoroscopic detectors. The resulting analysis shows that total noise content of the images processed by each method are inherently different based on their readout scheme. Finally, it will be shown that the NED is equivalent to the instrumentation-noise-equivalent-exposure (INEE) and furthermore that the NED is derived from the quantum-noise-only method of determining QLD. Future investigations will measure quantum-limited performance of radiographic panels with a modified readout scheme to allow for noise improvements similar to measurements performed with fluoroscopic detectors.

  16. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    the shoulder or thyroid guard, and on the hand.7. Radiologists receive larger radia- tion doses during abdominal studies than during cerebral studies, even though the .... body reading. The sitting position and the radiographer's physical build would also influence the reading. An ineffective thyroid guard, openings on.

  17. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  18. Benzodiazepine Initiation and Dose Escalation.

    Science.gov (United States)

    Skinner, Brian W; Johnston, Elizabeth V; Saum, Lindsay M

    2017-04-01

    Benzodiazepines (BZDs) place patients at a significant risk of falling. The current literature does not address if this risk is increased during initiation or dose escalations of BZDs. To determine if initiation or dose escalations of BZD regimens are associated with an increased risk of falls in hospitalized patients compared with patients maintained on their home dose or who had their dose decreased from baseline. This retrospective case-control study evaluated hospitalized patients aged 45 years or older who received a BZD. Patients who did not fall were collected in a 3:1 ratio to patients who fell. Comparisons were made between BZD regimens prior to admission and those 48 hours prior to the index date. The date of fall served as the index date for patients who fell, and the median time-to-fall served as the index date for all other patients. A total of 132 patients were included in the study (33 falls and 99 without a fall). No significant differences were noted in demographics, baseline mobility, or past medical history. Patients who fell had a significantly longer median length of stay (15 vs 10 days; P = 0.025). Additionally, patients who fell were more likely to have had their BZD regimen initiated or dose escalated compared with patients who did not fall (63.6% vs 41.4%; P = 0.043). The risk of falling while on a BZD is increased on initiation and dose escalations. Hospitals should ensure judicious use of BZDs in inpatients to reduce the risk of falls.

  19. Natural radiation dose to Gammarus

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Wrenn, M.E.; Eisenbud, M.

    1975-01-01

    The natural radiation dose rate to whole body and components of the Gammarus species (i.e., G. Tigrinus, G. Fasciatus and G. Daiberi) that occurs in the Hudson River is evaluated and the results compared with the upper limits of dose rates from man made sources to the whole body of the organisms. Methods were developed to study the distribution of alpha emitters from 226 Ra plus daughter products in Gammarus using autoradiographic techniques, taking into account the amount of radon that escapes from the organisms. This methodology may be adapted to study the distribution of alpha emitters in contaminated tissues of plants and animals

  20. Dose budget for exposure control

    International Nuclear Information System (INIS)

    Nair, P.S.

    1999-01-01

    Dose budget is an important management tool to effectively control the collective dose incurred in a nuclear facility. The budget represents a set of yardsticks or guidelines for use in controlling the internal activities, involving radiation exposure in the organisation. The management, through budget can evaluate the radiation protection performance at every level of the organisation where a number of independent functional groups work on routine and non-routine jobs. The discrepancy between the plan and the actual performance is high lighted through the budgets. The organisation may have to change the course of its operation in a particular area or revise its plan with due focus on appropriate protective measures. (author)

  1. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  2. Confectionery-based dose forms.

    Science.gov (United States)

    Tangso, Kristian J; Ho, Quy Phuong; Boyd, Ben J

    2015-01-01

    Conventional dosage forms such as tablets, capsules and syrups are prescribed in the normal course of practice. However, concerns about patient preferences and market demands have given rise to the exploration of novel unconventional dosage forms. Among these, confectionery-based dose forms have strong potential to overcome compliance problems. This report will review the availability of these unconventional dose forms used in treating the oral cavity and for systemic drug delivery, with a focus on medicated chewing gums, medicated lollipops, and oral bioadhesive devices. The aim is to stimulate increased interest in the opportunities for innovative new products that are available to formulators in this field, particularly for atypical patient populations.

  3. Optimizing lithium dosing in hemodialysis

    DEFF Research Database (Denmark)

    Bjarnason, N H; Munkner, R; Kampmann, J P

    2006-01-01

    in which we developed an algorithm based on a 2-compartment distribution without elimination. The GFR estimate led to plasma concentrations 3-4 times lower than those anticipated. In contrast, the estimates based on V(d) and the algorithm derived from pharmacokinetic modeling led to comparable loading dose...... estimates. Furthermore, the maintenance dose estimated from the central compartment (V1) led to plasma concentrations within the therapeutic range. Thus, a regimen where 12.2 mmol lithium was given after each hemodialysis session resulted in stable between-dialysis plasma lithium concentrations...

  4. Recomendações para se evitar grandes erros de dose em tratamentos radioterapêuticos Recommendations to avoid gross errors of dose in radiotherapeutic treatments

    Directory of Open Access Journals (Sweden)

    Cleber Nogueira de Souza

    2001-02-01

    Full Text Available Erros humanos são uma importante fonte de falhas em todos os passos do planejamento e do tratamento radioterapêutico. Com o objetivo de reduzir este grau de incerteza, várias organizações especializadas recomendam minuciosos programas de garantia da qualidade. No Brasil, programas deste tipo vêm tendo sua exigência intensificada, e a maioria dos serviços de radioterapia vem se orientando neste sentido, tanto em relação aos equipamentos de radiação e dosimetria, quanto em relação à verificação dos cálculos de dose em pacientes e das revisões das fichas de planejamento. Como uma contribuição a este esforço de qualidade, apresentam-se algumas recomendações para se evitar falhas de tratamento devidas a erros na dose de radiação recebida pelo paciente, como redundância nas verificações dos cálculos feitos manualmente ou por computador, e, também, a verificação da dose acumulada para cada paciente sob tratamento, semanalmente, além de se evitar a possibilidade de acesso a qualquer sistema de segurança do equipamento ao pessoal técnico treinado para apenas o operar. Além disso, deve-se considerar a possibilidade de se empregar um sistema computadorizado de verificação e registro do tratamento, dessa maneira prevenindo-se erros durante a aplicação diária devidos à seleção indevida dos diferentes parâmetros do tratamento. Reportam-se quatro incidentes radioativos recentes ocorridos no mundo, com injúrias em pacientes, e algumas ocorrências de erros grandes de dose.Human mistakes are an important source of errors in radiotherapy and may occur at every step of the radiotherapeutic planning and treatment. To reduce this level of uncertainties, several specialized organizations have recommended a comprehensive quality assurance program. In Brazil, the requirement for these programs has been strongly stressed, and most radiotherapy services have pursued this goal regarding radiation units and dosimetry equipment

  5. Yield in cultivars of the West Indian gherkin for different doses of biofertiliser = Produtividade de cultivares de maxixeiro em função de doses de biofertilizante

    Directory of Open Access Journals (Sweden)

    Lucas Pereira Gomes

    2015-10-01

    Full Text Available The fruit of the West Indian gherkin is greatly appreciated in Brazilian cuisine, especially in the north and northeast of Brazil. However, it is still considered a secondary crop, and is cultivated using non-technical management. As it is a crop produced mainly by small farmers, any research should be directed towards its cultivation using inputs produced on the farm itself, such as bio-fertilisers. The aim of this study was to evaluate the effect on the yield of two West Indian gherkin cultivars, of different doses of bio-fertiliser consisting of cattle manure and commercial products containing bacteria and enzymes that degrade organic molecules. A completely randomised design was used in a 2 x 4 factorial scheme with four replications. The factors included two cultivars (Do Norte and Liso Gibão and four doses of bio-fertiliser (0, 8, 16 and 24 m3 ha-1 applied through fertigation. The experiment lasted for 100 days, with six collections being made, for which the following variables were evaluated: number of fruits, fruit weight, production and yield. All the variables were affected by the interaction between the factors under study. The cultivars did not differ as to yield, however the De North cultivar gave the highest number of fruits, while the Liso Gibão cultivar produced fruit of a greater weight. From the results obtained, a dose of 14 m3 ha-1 is recommended for the Liso Gibão cultivar. For the De Norte cultivar, further studies with higher doses of bio-fertiliser are recommended. = Os frutos de maxixeiro são de grande apreciação na culinária brasileira, principalmente nas regiões Norte e Nordeste do Brasil. No entanto, é considerada uma cultura secundária e seu cultivo é realizado sem adoção de manejo tecnificado. Devido o seu cultivo ser realizado, principalmente, por pequenos produtores, as pesquisas empregando insumos produzidos na própria propriedade, como o biofertilizante, na adubação do maxixe são relevantes

  6. Dose reduction - the radiologist's view

    International Nuclear Information System (INIS)

    Russell, J.G.B.

    1984-01-01

    The magnitude of the exposure to ionising radiation dominates radiological practice in only three fields, i.e. foetal radiography, mammography and computed tomography. The balance between risk and benefit are briefly examined. The types of hazard considered are carcinogenesis, genetic injury and organogenesis. Ways of achieving a reduction of the dose to the patient are also briefly discussed. (U.K.)

  7. Peritoneal Dialysis Dose and Adequacy

    Science.gov (United States)

    ... done in the mid-afternoon to increase the amount of waste removed and to prevent excessive absorption of fluid. The dialysis solution used for the long daytime dwell may have a higher concentration ... amount, or dose, of dialysis. The peritoneal equilibration test— ...

  8. The cost of occupational dose

    International Nuclear Information System (INIS)

    Fleishman, A.B.; Clark, M.J.

    1980-01-01

    The optimization of radiological protection will routinely involve the balancing of public and occupational exposure, particularly within the nuclear fuel cycle. For example the reduction of public exposure from an effluent stream could lead to increases in occupational exposure from treatment, storage and disposal operations. A methodology is propased for the estimation of the cost of occupational exposure in the UK (Pound man-Sv -1 ) based on valuations of changes in risk. A variable value for the cost of the occupational man-Sv is obtained depending on per caput dose levels. The values at particular per caput dose levels are different for occupational workers and the general public, because of different demography and assumptions on risk perception and aversion. They are however approximately the same when the per caput doses are expressed as percentages of the dose limits for workers and the general public respectively. An example of the application of the derived cost of the occupational man-Sv to an optimisation problem is given. (author)

  9. Dose response relationship and Alara

    International Nuclear Information System (INIS)

    Hubert, P.

    1986-09-01

    In this paper, it will be shown how dose-response relationships allow to give quantitative figures for the detriment of irradiation. At this stage, the detriment is expressed directly as a certain number of health effects, whose valuation is not dealt with here. The present tools for quantifying, their weaknesses and their strenghts, and their scientific basis will be developed

  10. Comparison of Nordic dose models

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.

    1978-04-01

    A comparison is made between the models used in the four Nordic countries, Finland, Norway, Sweden and Denmark, for calculation of concentrations and doses from releases of radioactive material to the atmosphere. The comparison is limited to the near-zone models, i.e. the models for calculation of concentrations and doses within 50 km from the release point, and it comprises the following types of calculation: a. Concentrations of airborne material, b. External gamma doses from a plume, c. External gamma doses from radioactive material deposited on the ground. All models are based on the gaussian dispersion model (the gaussian plume model). Unit releases of specific isotopes under specific meteorological conditions are assumed. On the basis of the calculation results from the models, it is concluded that there are no essential differences. The difference between the calculation results only exceeds a factor of 3 in special cases. It thus lies within the known limits of uncertainty for the gaussian plume model. (author)

  11. Dose modeling in ultraviolet phototherapy

    International Nuclear Information System (INIS)

    Grimes, David Robert; Robbins, Chris; O'Hare, Neil John

    2010-01-01

    Purpose: Ultraviolet phototherapy is widely used in the treatment of numerous skin conditions. This treatment is well established and largely beneficial to patients on both physical and psychological levels; however, overexposure to ultraviolet radiation (UVR) can have detrimental effects, such as erythemal responses and ocular damage in addition to the potentially carcinogenic nature of UVR. For these reasons, it is essential to control and quantify the radiation dose incident upon the patient to ensure that it is both biologically effective and has the minimal possible impact on the surrounding unaffected tissue. Methods: To date, there has been little work on dose modeling, and the output of artificial UVR sources is an area where research has been recommended. This work characterizes these sources by formalizing an approach from first principles and experimentally examining this model. Results: An implementation of a line source model is found to give impressive accuracy and quantifies the output radiation well. Conclusions: This method could potentially serve as a basis for a full computational dose model for quantifying patient dose.

  12. Dose limits for ionising radiation

    International Nuclear Information System (INIS)

    Gifford, D.

    1989-01-01

    Dose limits for exposure to ionising radiation are assessed to see if they give sufficient protection both for the occupationally exposed and for the general public. It is concluded that current limits give a level of safety that satisfies the necessary criteria in the light of present knowledge and further reductions would be unlikely to improve standards of safety. (author)

  13. Investigations of peripheral dose for helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lissner, Steffen; Schubert, Kai; Sterzing, Florian; Herfarth, Klaus; Sroka-Perez, Gabriele; Debus, Juergen [University Hospital Heidelberg (Germany). Dept. of Radiation Oncology; Wiezorek, Tilo [University Hospital Jena (Germany). Dept. of Radiotherapy

    2013-07-01

    Purpose: Whenever treating a patient with percutaneous radiotherapy, a certain amount of dose is inevitably delivered to healthy tissue. This is mainly due to beam's entry and exit in the region of the target volume. In regions distant from the target volume, dose is delivered by leakage from the MLC and head scatter from the accelerator head and phantom scatter from the target volume (peripheral dose). Helical tomotherapy is a form of radiation therapy with a uniquely designed machine and delivery pattern which influence the peripheral dose. The goal of this work was to investigate peripheral dose in helical tomotherapy. The experiments were used to establish a complex characterization of the peripheral dose. Materials and methods: A 30*30*60cm{sup 3} slab phantom and TLD-100 (Lithium fluoride) were used for the experiments. Treatment procedures were generated with the tomotherapy planning system (TPS). Additionally, procedures were created on the Operator Station of the tomotherapy system without a calculation of the dose distribution. The peripheral dose which was produced by a typical tomotherapy treatment plan was measured. Furthermore, these procedures were used to differentiate the parts of the peripheral dose in phantom scatter dose and head scatter and leakage dose. Additionally, the relation between peripheral dose and treatment time and between peripheral dose and delivered dose was investigated. Additionally, the peripheral dose was measured in an Alderson phantom. Results: Distances of 30cm or more resulted in a decrease of the peripheral dose to less than 0.1% of the target dose. The measured doses have an offset of approximately 1cGy in comparison to the calculated doses from the TPS. The separated head scatter and leakage dose was measured in the range of 1cGy for typical treatments. Furthermore, the investigations show a linear correlation between head scatter leakage dose and treatment time and between scatter dose parts and delivered dose. A

  14. Tank Z-361 dose rate calculations

    International Nuclear Information System (INIS)

    Richard, R.F.

    1998-01-01

    Neutron and gamma ray dose rates were calculated above and around the 6-inch riser of tank Z-361 located at the Plutonium Finishing Plant. Dose rates were also determined off of one side of the tank. The largest dose rate 0.029 mrem/h was a gamma ray dose and occurred 76.2 cm (30 in.) directly above the open riser. All other dose rates were negligible. The ANSI/ANS 1991 flux to dose conversion factor for neutrons and photons were used in this analysis. Dose rates are reported in units of mrem/h with the calculated uncertainty shown within the parentheses

  15. Neutron stimulated emission computed tomography applied to the assessment of calcium deposition due to the presence of microcalcifications associated with breast cancer; Tomografia computadorizada de emissao estimulada por neutrons aplicada para avaliar a deposicao de calcio devido a presenca de microcalcificacoes associadas ao cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Rodrigo S.S.; Yoriyaz, Helio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, (SP) (Brazil)

    2011-07-01

    In this paper we presented an application of the Neutron Stimulated Emission Computed Tomography (NSECT), which uses a thin beam of fast neutrons to stimulate stable nuclei in a sample, emitting characteristic gamma radiation. The photon energy is unique and it is used to identify the emitting nuclei. This technique was applied for evaluating the calcium isotopic composition changing due to the development of breast microcalcifications. A particular situation was simulated in which clustered microcalcifications were modeled with diameters less than 1.40 mm. In this case, neutron beam breast spectroscopy was successful in detecting the counting changes in the photon emission spectra for energies, which are characteristics of 4{sup 0C}a isotope in a low deposited dose rate. (author)

  16. Concept of isoeffective doses in radiotherapy

    International Nuclear Information System (INIS)

    Ryabukhin, Yu.S.; Chekhonadskij, V.N.; Sushchikhina, M.A.

    1987-01-01

    The authors proposed the use of absorbed doses in standard regimens of irradiation to illustrate end-effects of unconventional variations of radiotherapy. They proposed that such doses should be defined as ''biological isoeffective doses under standard conditions of radiotherapy'' or, in short, ''standard isoeffective doses''. Three standard regimens of irradiation were described: separately for β-beam, for continuous interstitial and fractional intracavitary radiotherapy. It was proposed that a standard isoeffective dose value should be expressed in ''isogray'' abbreviated as (i) Gy

  17. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  18. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  19. Levothyroxine Dosing Following Bariatric Surgery.

    Science.gov (United States)

    Gadiraju, Silpa; Lee, Clare J; Cooper, David S

    2016-10-01

    Based on the mechanisms of drug absorption, increased levothyroxine requirements are expected after bariatric surgery. However, there are conflicting data on this topic. This review evaluates the effects of bariatric surgery on levothyroxine dosing. Data were obtained from PubMed, Scopus, and review of published bibliographies. Six of 10 studies demonstrated decreased postoperative requirements. Most demonstrated correlations between weight loss and dose. Only 3 case reports and 1 case series demonstrated increased levothyroxine requirements, attributed to malabsorption. The loss of both fat and lean body mass may counteract malabsorptive effects from surgery, resulting in decreased postoperative levothyroxine requirements. In addition, the reversal of impaired levothyroxine pharmacokinetics and an altered set point of thyroid hormone homeostasis may also contribute to postoperative levothyroxine reductions.

  20. Dose assessment in radiological accidents

    International Nuclear Information System (INIS)

    Donkor, S.

    2013-04-01

    The applications of ionizing radiation bring many benefits to humankind, ranging from power generation to uses in medicine, industry and agriculture. Facilities that use radiation source require special care in the design and operation of equipment to prevent radiation injury to workers or to the public. Despite considerable development of radiation safety, radiation accidents do happen. The purpose of this study is therefore to discuss how to assess doses to people who will be exposed to a range of internal and external radiation sources in the event of radiological accidents. This will go a long way to complement their medical assessment thereby helping to plan their treatment. Three radiological accidents were reviewed to learn about the causes of those accidents and the recommendations that were put in place to prevent recurrence of such accidents. Various types of dose assessment methods were discussed.(au)

  1. Atmospheric radiation flight dose rates

    Science.gov (United States)

    Tobiska, W. K.

    2015-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has been conducting space weather observations of the atmospheric radiation environment at aviation altitudes that will eventually be transitioned into air traffic management operations. The Automated Radiation Measurements for Aerospace Safety (ARMAS) system and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) both are providing dose rate measurements. Both activities are under the ARMAS goal of providing the "weather" of the radiation environment to improve aircraft crew and passenger safety. Over 5-dozen ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. Flight altitudes now exceed 60,000 ft. and extend above commercial aviation altitudes into the stratosphere. In this presentation we describe recent ARMAS and USEWX results.

  2. Urban contamination and dose model

    International Nuclear Information System (INIS)

    Robertson, E.; Barry, P.J.

    1995-10-01

    Nuclear power reactors and other nuclear facilities are being built near or even within urban centres. Accidental releases of radionuclides to the atmosphere in built-up areas result in radiological exposure pathways that differ from those caused by releases in rural environments. Other than inhalation, exposure pathways involve external radiation from the plume while it passes and from radioactivity deposited onto the many and varied surfaces after it has passed. Radiation fields inside buildings are attenuated but many people are potentially exposed so while individual doses may be relatively low, population integrated doses may be high enough to cause concern. It is important, therefore, to assess the potential exposures and to estimate the cost-effectiveness of dose reduction measures in urban environments. This report describes a model developed to carry out such assessments. The model draws heavily on experience gained in European cities after their contamination fallout from the Chernobyl accident. Input is time integrated concentrations of specific radionuclides in urban air, obtained either by direct measurement or by prediction using an atmospheric dispersion model. The code includes default values for site specific variables and transfer parameters but the user is invited if desired to enter other values from the keyboard. Output is the time integrated dose rates for individuals selected because of the characteristic living, working and recreational habits. An accompanying manual documents the technical background on which the model is based and leads a first-time suer through various steps and operations encountered while the model is running. (author). 60 refs., 10 tabs., 1 fig

  3. Dose assessment models. Annex A

    International Nuclear Information System (INIS)

    1982-01-01

    The models presented in this chapter have been separated into 2 general categories: environmental transport models which describe the movement of radioactive materials through all sectors of the environment after their release, and dosimetric models to calculate the absorbed dose following an intake of radioactive materials or exposure to external irradiation. Various sections of this chapter also deal with atmospheric transport models, terrestrial models, and aquatic models.

  4. Tolerance doses for treatment planning

    International Nuclear Information System (INIS)

    Lyman, J.T.

    1985-10-01

    Data for the tolerance of normal tissues or organs to (low-LET) radiation has been compiled from a number of sources which are referenced at the end of this document. This tolerance dose data are ostensibly for uniform irradiation of all or part of an organ, and are for either 5% (TD 5 ) or 50% (TD 50 ) complication probability. The ''size'' of the irradiated organ is variously stated in terms of the absolute volume or the fraction of the organ volume irradiated, or the area or the length of the treatment field. The accuracy of these data is questionable. Much of the data represents doses that one or several experienced therapists have estimated could be safely given rather than quantitative analyses of clinical observations. Because these data have been obtained from multiple sources with possible different criteria for the definition of a complication, there are sometimes different values for what is apparently the same endpoint. The data from some sources shows a tendancy to be quantized in 5 Gy increments. This reflects the size of possible round off errors. It is believed that all these data have been accumulated without the benefit of 3-D dose distributions and therefore the estimates of the size of the volume and/or the uniformity of the irradiation may be less accurate than is now possible. 19 refs., 4 figs

  5. Tolerance doses for treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Lyman, J.T.

    1985-10-01

    Data for the tolerance of normal tissues or organs to (low-LET) radiation has been compiled from a number of sources which are referenced at the end of this document. This tolerance dose data are ostensibly for uniform irradiation of all or part of an organ, and are for either 5% (TD/sub 5/) or 50% (TD/sub 50/) complication probability. The ''size'' of the irradiated organ is variously stated in terms of the absolute volume or the fraction of the organ volume irradiated, or the area or the length of the treatment field. The accuracy of these data is questionable. Much of the data represents doses that one or several experienced therapists have estimated could be safely given rather than quantitative analyses of clinical observations. Because these data have been obtained from multiple sources with possible different criteria for the definition of a complication, there are sometimes different values for what is apparently the same endpoint. The data from some sources shows a tendancy to be quantized in 5 Gy increments. This reflects the size of possible round off errors. It is believed that all these data have been accumulated without the benefit of 3-D dose distributions and therefore the estimates of the size of the volume and/or the uniformity of the irradiation may be less accurate than is now possible. 19 refs., 4 figs.

  6. Automated effective dose estimation in CT.

    Science.gov (United States)

    García, M Sánchez; Cameán, M Pombar; Busto, R Lobato; Vega, V Luna; Sueiro, J Mosquera; Martínez, C Otero; del Río, J R Sendón

    2010-01-01

    European regulations require the dose delivered to patients in CT examinations to be monitored and checked against reference levels. Dose estimation has traditionally been performed manually. This is time consuming and therefore it is typically performed on just a few patients and the results extrapolated to the general case. In this work an automated method to estimate the dose in CT studies is presented. The presented software downloads CT studies from the corporative picture archiving and communication system and uses the information on the DICOM headers to perform the dose calculation. Automation enables dose estimations to be performed on a larger fraction of studies, enabling more significant comparisons with diagnostic reference levels (DRLs). A preliminary analysis involving 5800 studies is presented with details of dose distributions for selected CT protocols in use at a university hospital. Average doses are compared with DRLs. Effective dose estimations are also compared with estimations based on the dose length product.

  7. Collective dose commitments from nuclear power programmes

    International Nuclear Information System (INIS)

    Beninson, D.

    1977-01-01

    The concepts of collective dose and collective dose commitment are discussed, particularly regarding their use to compare the relative importance of the exposure from several radiation sources and to predict future annual doses from a continuing practice. The collective dose commitment contributions from occupational exposure and population exposure due to the different components of the nuclear power fuel cycle are evaluated. A special discussion is devoted to exposures delivered over a very long time by released radionuclides of long half-lives and to the use of the incomplete collective dose commitment. The maximum future annual ''per caput'' doses from present and projected nuclear power programmes are estimated

  8. Editorial: New operational dose equivalent quantities

    International Nuclear Information System (INIS)

    Harvey, J.R.

    1985-01-01

    The ICRU Report 39 entitled ''Determination of Dose Equivalents Resulting from External Radiation Sources'' is briefly discussed. Four new operational dose equivalent quantities have been recommended in ICRU 39. The 'ambient dose equivalent' and the 'directional dose equivalent' are applicable to environmental monitoring and the 'individual dose equivalent, penetrating' and the 'individual dose equivalent, superficial' are applicable to individual monitoring. The quantities should meet the needs of day-to-day operational practice, while being acceptable to those concerned with metrological precision, and at the same time be used to give effective control consistent with current perceptions of the risks associated with exposure to ionizing radiations. (U.K.)

  9. Fewer Doses of HPV Vaccine Result in Immune Response Similar to Three-Dose Regimen

    Science.gov (United States)

    ... Note Fewer doses of HPV vaccine result in immune response similar to three-dose regimen Posted: November 4, ... or three doses of Cervarix. They also measured immune responses of unvaccinated women who, at enrollment, were found ...

  10. Dose-mapping distribution around MNSR

    CERN Document Server

    Jamal, M H

    2002-01-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear.

  11. Calibration of dose meters used in radiotherapy

    International Nuclear Information System (INIS)

    1979-01-01

    This manual is a practical guide, not a comprehensive textbook, to the instrumentation and procedures necessary to calibrate a radiation dose meter used in clinical practice against a secondary standard dose meter

  12. Organ doses from computerized tomography examinations

    International Nuclear Information System (INIS)

    Janeczek, J.

    1995-01-01

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs

  13. Fluzone High-Dose Seasonal Influenza Vaccine

    Science.gov (United States)

    ... Dose vaccine available? This vaccine is approved for marketing in 0.5 mL preservative-free, single dose, ... Branch, Division of Public Affairs Email Recommend Tweet YouTube Instagram Listen Watch RSS ABOUT About CDC Jobs ...

  14. Dose-rate dependence of thermoluminescence response

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Chen, R.; Groom, P.J.; Durrani, S.A.

    1980-01-01

    The previously observed dose-rate effect of thermoluminescence in quartz at high dose-rates is given at theoretical formulation. Computer calculations simulating the experimental conditions yield similar results to the experimental ones. (orig.)

  15. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  16. Dose estimation by biological methods

    International Nuclear Information System (INIS)

    Guerrero C, C.; David C, L.; Serment G, J.; Brena V, M.

    1997-01-01

    The human being is exposed to strong artificial radiation sources, mainly of two forms: the first is referred to the occupationally exposed personnel (POE) and the second, to the persons that require radiological treatment. A third form less common is by accidents. In all these conditions it is very important to estimate the absorbed dose. The classical biological dosimetry is based in the dicentric analysis. The present work is part of researches to the process to validate the In situ Fluorescent hybridation (FISH) technique which allows to analyse the aberrations on the chromosomes. (Author)

  17. Dose-response relationship in clinical oncology

    International Nuclear Information System (INIS)

    Gehan, E.A.

    1984-01-01

    The relationship of dose (and dose rate) to response and toxicity in clinical oncology is reviewed. The concepts expressed by some authors in dose-response studies in animal and human systems are reviewed briefly. Dose rate and tactics of conducting clinical studies are reviewed for both radiotherapy and various types of chemotherapeutic treatment. Examples are given from clinical studies in Hodgkin's disease, acute leukemia, and breast cancer that may prove useful in planning future clinical studies

  18. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  19. Hanford Environmental Dose Reconstruction Project. Monthly report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. [comps.

    1992-04-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): Source terms, environmental transport, environmental monitoring data, demography, food consumption, and agriculture, and environmental pathways and dose estimates.

  20. Hanford Environmental Dose Reconstruction Project Monthly Report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. (comps.)

    1992-03-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates.

  1. Hanford Environmental Dose Reconstruction Project. Monthly report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M.; McMakin, A.H. [comps.

    1992-02-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demography, food consumption, and agriculture; environmental pathways and dose estimates.

  2. Hanford Environmental Dose Reconstruction Project. Monthly report

    Energy Technology Data Exchange (ETDEWEB)

    Cannon, S.D.; Finch, S.M. [comps.

    1992-10-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates):Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates.

  3. Multiple anatomy optimization of accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, W. Tyler, E-mail: watkinswt@virginia.edu; Siebers, Jeffrey V. [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Moore, Joseph A. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Gordon, James [Henry Ford Health System, Detroit, Michigan 48202 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Hugo, Geoffrey D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2014-11-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  4. Multiple anatomy optimization of accumulated dose.

    Science.gov (United States)

    Watkins, W Tyler; Moore, Joseph A; Gordon, James; Hugo, Geoffrey D; Siebers, Jeffrey V

    2014-11-01

    To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  5. Multiple anatomy optimization of accumulated dose

    International Nuclear Information System (INIS)

    Watkins, W. Tyler; Siebers, Jeffrey V.; Moore, Joseph A.; Gordon, James; Hugo, Geoffrey D.

    2014-01-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated

  6. Failure-probability driven dose painting

    DEFF Research Database (Denmark)

    Vogelius, Ivan R; Håkansson, Katrin; Due, Anne K

    2013-01-01

    To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study...

  7. Dose optimisation in single plane interstitial brachytherapy.

    Science.gov (United States)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte; Nielsen, Søren Kynde; Olsen, Dag Rune; Grau, Cai; Lindegaard, Jacob Christian

    2006-10-01

    Brachytherapy dose distributions can be optimised by modulation of source dwell times. In this study dose optimisation in single planar interstitial implants was evaluated in order to quantify the potential benefit in patients. In 14 patients, treated for recurrent rectal and cervical cancer, flexible catheters were sutured intra-operatively to the tumour bed in areas with compromised surgical margin. Both non-optimised, geometrically and graphically optimised CT -based dose plans were made. The overdose index (OI), homogeneity index (HI), conformal index (COIN), minimum target dose, and high dose volumes were evaluated. The dependence of OI, HI, and COIN on target volume and implant regularity was evaluated. In addition, 12 theoretical implant configurations were analyzed. Geometrical and graphical optimisation improved the dose plans significantly with graphical optimisation being superior. Graphically optimised dose plans showed a significant decrease of 18%+/-9% in high dose volume (pusability of these parameters for comparison of dose plans between patients. Dwell time optimisation significantly improved the dose distribution regarding homogeneity, conformity, minimum target dose, and size of high dose volumes. Graphical optimisation is fast, reproducible and superior to geometric optimisation.

  8. Chemical Dosing and First-Order Kinetics

    Science.gov (United States)

    Hladky, Paul W.

    2011-01-01

    College students encounter a variety of first-order phenomena in their mathematics and science courses. Introductory chemistry textbooks that discuss first-order processes, usually in conjunction with chemical kinetics or radioactive decay, stop at single, discrete dose events. Although single-dose situations are important, multiple-dose events,…

  9. Maternal methadone dosing schedule and fetal neurobehavior

    Science.gov (United States)

    Jansson, Lauren M.; DiPietro, Janet A.; Velez, Martha; Elko, Andrea; Knauer, Heather; Kivlighan, Katie T.

    2008-01-01

    Objective Daily methadone maintenance is the standard of care for opiate dependency during pregnancy. Previous research has indicated that single-dose maternal methadone administration significantly suppresses fetal neurobehaviors. The purpose of this study was to determine if split-dosing would have less impact on fetal neurobehavior than single-dose administration. Methods Forty methadone-maintained women were evaluated at peak and trough maternal methadone levels on single- and split-dosing schedules. Monitoring sessions occurred at 36 and 37 weeks gestation in a counterbalanced study design. Fetal measures included heart rate, variability, accelerations, motor activity and fetal movement-heart rate coupling (FM-FHR). Maternal measures included heart period, variability, skin conductance, respiration and vagal tone. Repeated measure analysis of variance was used to evaluate within-subject changes between split- and single-dosing regimens. Results All fetal neurobehavioral parameters were suppressed by maternal methadone administration, regardless of dosing regimen. Fetal parameters at peak were significantly lower during single vs. split methadone administration. FM-FHR coupling was less suppressed from trough to peak during split-dosing vs. single-dosing. Maternal physiologic parameters were generally unaffected by dosing condition. Conclusion Split- dosed fetuses displayed less neurobehavioral suppression from trough to peak maternal methadone levels as compared to single-dosed fetuses. Split-dosing may be beneficial for methadone-maintained pregnant women. PMID:19085624

  10. RADIATION DOSE IN PAEDIATRIC COMPUTED TOMOGRAPHY ...

    African Journals Online (AJOL)

    This CT facility at the time of writing also did not use a documented guideline and protocol for imaging children. RADIATION DOSE. The amount of radiation energy deposited in a medium is called the radiation dose. Different x-ray modalities address radiation dose in different ways. For example, in chest radiography it is the ...

  11. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  12. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  13. Dose mapping role in gamma irradiation industry

    International Nuclear Information System (INIS)

    Noriah Mod Ali; John Konsoh Sangau; Mazni Abd Latif

    2002-01-01

    In this studies, the role of dosimetry activity in gamma irradiator was discussed. Dose distribution in the irradiator, which is a main needs in irradiator or chamber commissioning. This distribution data were used to confirm the dosimetry parameters i.e. exposure time, maximum and minimum dose map/points, and dose distribution - in which were used as guidelines for optimum product irradiation. (Author)

  14. Doses in mammography. Preliminary study

    International Nuclear Information System (INIS)

    Marquez P, F.; Acosta R, N.; Universidad Nacional Mayor de San Marcos, Lima; Benavente, T.; Universidad Nacional Mayor de San Marcos, Lima; Poma, M.

    2002-01-01

    Mammography is the most important method to detect lesions in the breast with this technique one can detect small tumours before clear clinical symptoms appear. Mammographic image of require high quality standards due that the extremely low contrast between the normal and pathological areas in the breast, eg.g., they have similar attenuation and absorption coefficient. The x-ray mammographic systems, used in this study are Senographe 500t and Senographe DMR, a detector with a RadCal ionization chambers calibrated to the qualities of mammographic x-ray beams, and a breast simulator that is a phantoms of polymethylmethacrylate (PMMA) of several thicknesses with the equivalence of 50% of the glandular tissue. The results obtained indicate that the values of doses at the entrance surface of a breast (DES) are greater the reference value 20 mGy to 5,0 cm of PMMA and the values of the mean glandular dose (MGD) exceed the reference value of 2,1 mGy for 5,1 cm of compressed thick breast. We consider that the values high of the EDS and MGD are due that the x-ray systems no meeting in good condition or for used of x-ray spectra no suitable, so is recommendable be carried out test of quality control to the x-ray systems and also realize studies, or characterize the of x-ray mammographic spectra

  15. Patient doses in interventional cardiology

    International Nuclear Information System (INIS)

    Carrera, F.; Ojeda, C.; Ruiz-Cruces, R.; Francisco Diaz, J.; Sanchez, A.; Tort, I.

    2001-01-01

    Cardiovascular diseases are the first cause of death in Spain. The most usual procedures in interventional cardiology are coronariography and PTCA. The first is a diagnostic technique, and the second one is interventional. Our goal has been to study procedures made during the first six months in the Interventional Cardiology Unit of the Juan Ramon Jimenez Hospital (Huelva-Spain), taking into account radiation protection issues. We have studied 178 patients; 145 of them underwent coronariography, and 33 of the patients had PTCA too. Every case was analyzed taking into account technical and dosimetric parameters. We show parameters values gathered: Diagnostic techniques (valvular and non-valvular patients), and interventional techniques (coronariography and PTCA in different or in the same intervention). Higher doses were obtained with valvular patients, although the number of frames was similar. Attending to therapeutic procedures, the highest values were gotten with the 'double' interventions. Interventional procedures exceed in 60% doses gotten in diagnostic studies: this is because of the number of series and number of frames per series. Similar values obtained by other authors have been gotten. (author)

  16. Discuss on luminescence dose data analysis technology

    International Nuclear Information System (INIS)

    Ma Xinhua; Xiao Wuyun; Ai Xianyun; Shi Zhilan; Liu Ying

    2009-01-01

    This article describes the development of luminescence dose data measurement and processing technology. General design planning of luminescence dose data measurement and processing technology is put forward with the diverse demands. The emphasis is focused on dose data processing method, luminescence curve analysis method, using of network, mechanics of communication among computers, data base management system of individual dose in this paper. The main methods and skills used in this technology as well as their advantages are also discussed. And it offers general design references for development luminescence dose data processing software. (authors)

  17. Dose Rate Effects in Linear Bipolar Transistors

    Science.gov (United States)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  18. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  19. The concept of the effective dose

    International Nuclear Information System (INIS)

    Jacobi, W.

    1975-01-01

    Irradiation of the human body by external or internal sources leads mostly to a simultaneous exposure of several organs. However, so far no clear and consistent recommendations for the combination of organ doses and the assessment of an exposure limit under such irradiation conditions are available. Following a proposal described in ICRP-publication 14 one possible concept for the combination of organ doses is discussed in this paper. This concept is based on the assumption that at low doses the total radiation detriment to the exposed person is given by the sum of radiation detriments to the single organs. Taking into account a linear dose-risk relationship, the sum of weighted organ doses leads to the definition of an 'Effective Dose'. The applicability and consequences of this 'Effective Dose Concept' are discussed especially with regard to the assessment of the maximum permissible intake of radionuclides into the human body and the combination of external and internal exposure. (orig.) [de

  20. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  1. Cytogenetic effects of low-dose radiation

    International Nuclear Information System (INIS)

    Metalli, P.

    1983-01-01

    The effects of ionizing radiation on chromosomes have been known for several decades and dose-effect relationships are also fairly well established in the mid- and high-dose and dose-rate range for chromosomes of mammalian cells. In the range of low doses and dose rates of different types of radiation few data are available for direct analysis of the dose-effect relationships, and extrapolation from high to low doses is still the unavoidable approach in many cases of interest for risk assessment. A review is presented of the data actually available and of the attempts that have been made to obtain possible generalizations. Attention is focused on some specific chromosomal anomalies experimentally induced by radiation (such as reciprocal translocations and aneuploidies in germinal cells) and on their relevance for the human situation. (author)

  2. Salivary gland doses from dental radiographic exposures

    International Nuclear Information System (INIS)

    Hoshi, Masaharu; Kato, Kazuo; Wada, Takuro; Antoku, Shigetoshi; Russell, W.J.

    1989-01-01

    Salivary gland doses incurred during dental radiography were measured by phantom dosimetry, and these dose data and data obtained during a two-week survey of Hiroshima and Nagasaki dental hospitals and clinics were used to estimate the respective doses to members of the populations of the two cities. The results obtained were used to supplement previously determined doses to the thyroid gland, lens, and pituitary gland from dental radiography. No significant differences in doses were observed by age, sex or city. Doses to the salivary glands during dental radiography are probably not sufficiently large to cause bias in assessments of atomic bomb survivors for late radiation effects. However, the steadily increasing use of dental radiography underscores the need for continued monitoring of dental radiography doses in the interests of these assessments. (author)

  3. Dose Titration Algorithm Tuning (DTAT) should supersede ‘the’ Maximum Tolerated Dose (MTD) in oncology dose-finding trials

    Science.gov (United States)

    Norris, David C.

    2017-01-01

    Background. Absent adaptive, individualized dose-finding in early-phase oncology trials, subsequent ‘confirmatory’ Phase III trials risk suboptimal dosing, with resulting loss of statistical power and reduced probability of technical success for the investigational therapy. While progress has been made toward explicitly adaptive dose-finding and quantitative modeling of dose-response relationships, most such work continues to be organized around a concept of ‘the’ maximum tolerated dose (MTD). The purpose of this paper is to demonstrate concretely how the aim of early-phase trials might be conceived, not as ‘dose-finding’, but as dose titration algorithm (DTA)-finding. Methods. A Phase I dosing study is simulated, for a notional cytotoxic chemotherapy drug, with neutropenia constituting the critical dose-limiting toxicity. The drug’s population pharmacokinetics and myelosuppression dynamics are simulated using published parameter estimates for docetaxel. The amenability of this model to linearization is explored empirically. The properties of a simple DTA targeting neutrophil nadir of 500 cells/mm 3 using a Newton-Raphson heuristic are explored through simulation in 25 simulated study subjects. Results. Individual-level myelosuppression dynamics in the simulation model approximately linearize under simple transformations of neutrophil concentration and drug dose. The simulated dose titration exhibits largely satisfactory convergence, with great variance in individualized optimal dosing. Some titration courses exhibit overshooting. Conclusions. The large inter-individual variability in simulated optimal dosing underscores the need to replace ‘the’ MTD with an individualized concept of MTD i . To illustrate this principle, the simplest possible DTA capable of realizing such a concept is demonstrated. Qualitative phenomena observed in this demonstration support discussion of the notion of tuning such algorithms. Although here illustrated specifically

  4. Conventional radiology and genetic dose

    International Nuclear Information System (INIS)

    Gonzalez-Vila, V.; Fernandez, A.; Rivera, F.; Martinez, M.; Gomez, A.; Luis, J.

    1992-01-01

    A research project was established in 1984 to evaluate the expected genetic abnormalities due to radiation received by the population attending the Outpatient Radiological Service due to medical radiological practices. The study was conducted in 1985 (12 weeks chosen by random). The equivalent gonadal dose was the chosen parameter, representing the social cost of the radiology. Samples of 2945 men and 2929 women were considered in the study. The number of genetic abnormalities, in relation to the mean age of reproduction (a generation every 30 years), was 2.13 cases per million in the first generation and 15.97 cases per million at equilibrium. The authors interpretation is that both the method and the expected genetic detriment are suitable procedures for the characterisation of the Radiological Service as a radiation source. (author)

  5. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  6. Method of preparing radionuclide doses

    International Nuclear Information System (INIS)

    Kuperus, J.H.

    1987-01-01

    A method is described of preparing aliquot dosea of a tracer material useful in diagnostic nuclear medicine comprising: storing discrete quantities of a lyophilized radionuclide carrier in separate tubular containers from which air and moisture is excluded, selecting from the tubular containers a container in which is stored a carrier appropriate for a nuclear diagnostic test to be performed, interposing the selected container between the needle and the barrel of a hypodermic syringe, and drawing a predetermined amount of a liquid containing a radionuclide tracer in known concentration into the hypodermic syringe barrel through the hypodermic needle and through the selected container to dissolve the discrete quantity of lyophilized carrier therein to combine the carrier with the radionuclide tracer to form an aliquot dose of nuclear diagnostic tracer material, as needed

  7. Patient Dose From Megavoltage Computed Tomography Imaging

    International Nuclear Information System (INIS)

    Shah, Amish P.; Langen, Katja M.; Ruchala, Kenneth J.; Cox, Andrea; Kupelian, Patrick A.; Meeks, Sanford L.

    2008-01-01

    Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value

  8. Dose in x-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2014-02-01

    Radiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail. A review of approaches to patient dose assessment presently in practice, of the dose levels encountered and options for further dose optimization are also given and discussed. Patient dose assessment remains a topic for further improvement and for international consensus. All approaches presently in use are based on Monte Carlo (MC) simulations. Estimates for effective dose are established, but they are crude and not patient-specific; organ dose estimates are rarely available. Patient- and organ-specific dose estimates can be provided with adequate accuracy and independent of CTDI phantom measurements by fast MC simulations. Such information, in particular on 3D dose distributions, is important and helpful in optimization efforts. Dose optimization has been performed very successfully in recent years and even resulted in applications with effective dose values of below 1 mSv. In general, a trend towards lower dose values based on technical innovations has to be acknowledged. Effective dose values are down to clearly below 10 mSv on average, and there are a number of applications such as cardiac and pediatric CT which are performed routinely below 1 mSv on modern equipment.

  9. MONTEC, an interactive fortran program to simulate radiation dose and dose-rate responses of populations

    International Nuclear Information System (INIS)

    Perry, K.A.; Szekely, J.G.

    1983-09-01

    The computer program MONTEC was written to simulate the distribution of responses in a population whose members are exposed to multiple radiation doses at variable dose rates. These doses and dose rates are randomly selected from lognormal distributions. The individual radiation responses are calculated from three equations, which include dose and dose-rate terms. Other response-dose/rate relationships or distributions can be incorporated by the user as the need arises. The purpose of this documentation is to provide a complete operating manual for the program. This version is written in FORTRAN-10 for the DEC system PDP-10

  10. RISCOS OCUPACIONAIS QUÍMICOS NO CONHECIMENTO DE CIRURGIÕES DENTISTAS

    Directory of Open Access Journals (Sweden)

    Raquel Martins Arpone

    2012-06-01

    Full Text Available The consequences for the health of the work are the result of the interaction of the body with agents/factors existing in the working environment, characterizing the occupational exposure. The dentists are exposed to various occupational hazards, whether chemical, physical, mechanical, ergonomic or accidents. The aim of this study was identify whether dentists and dental students know the risks that they are exposed to chemicals during their practical work. A questionnaire was given to 33 dentists and 33 students of final year of Dentistry, about his knowledge of the chemical agents which dental professionals are exposed and what the risks posed by exposure to each of these agents. With the exception of ether and formaldehyde, most students are exposed to all the chemicals studied, while dentists are less exposed to ether, formaldehyde and surgical cement. The majority of students do 16 chemicals associated with health problems, including alcohol, antibacterial liquid soap, latex, powder, glutaraldehyde, sodium alginate and glass ionomer. Most dentists not associated products with 11 health problems, like a list of the students. None dentist and only 6.1% of the students associated the risk of cancer with exposure to cement/plaster. Only 24.2% of dentists and 21.1% of students associated methyl methacrylate exposure with lung disorders. Dentists and dental students don’t have an adequate knowledge of the risks involved with exposure to the chemicals they use every day, and it may result in not using appropriate protective equipment and occupational diseases.

  11. Hemoglobinopatias em trabalhadores expostos à riscos ocupacionais Hemoglobinopathies in workers exposed to occupational hazards

    Directory of Open Access Journals (Sweden)

    Isaac L. Silva Filho

    2002-12-01

    Full Text Available Hemoglobinopathies have been considered the most frequent hereditary disease in Brazilian population, constituting a Public Health problem. This paper reports on screening in workers at FIOCRUZ-RJ., exposed to some hazards factors such as, chemical substances, radiation, excessive cold and heat etc., with the objective of evaluating the impact of these factors in carriers of hemoglobinopathies, mainly in sickle cell trait (AS.

  12. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  13. Skin dose variation: influence of energy

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: This research aimed to quantitatively evaluate the differences in percentage dose of maximum for 6MV and 18MV x-ray beams within the first lcm of interactions. Thus provide quantitative information regarding the basal, dermal and subcutaneous dose differences achievable with these two types of high-energy x-ray beams. Percentage dose of maximum build up curves are measured for most clinical field sizes using 6MV and 18MV x-ray beams. Calculations are performed to produce quantitative results highlighting the percentage dose of maximum differences delivered to various depths within the skin and subcutaneous tissue region by these two beams Results have shown that basal cell layer doses are not significantly different for 6MV and 18Mv x-ray beams At depths beyond the surface and basal cell layer there is a measurable and significant difference in delivered dose. This variation increases to 20% of maximum and 22% of maximum at Imm and 1cm depths respectively. The percentage variations are larger for smaller field sizes where the photon in phantom component of the delivered dose is the most significant contributor to dose By producing graphs or tables of % dose differences in the build up region we can provide quantitative information to the oncologist for consideration (if skin and subcutaneous tissue doses are of importance) during the beam energy selection process for treatment. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  14. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  15. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  16. Use of dose constraints in public exposure

    International Nuclear Information System (INIS)

    Tageldein, Amged

    2015-02-01

    An overview of the dose constraints in public exposures has been carried out in this project. The establishment, development and the application of the concept of dose constraints are reviewed with regards to public exposure. The role of dose constraints in the process of optimization of radiation protection was described and has been showed that the concept of the dose constraints along with many other concept of radiation protection is widely applied in the optimization of exposure to radiation. From the beginning of the establishment of dose constraints as a concept in radiation protection, the International Commission of Radiological Protection (ICRP) has published a number of documents that provides detailed application related to radiation protection and safety of public exposure from ionizing radiation. This work provides an overview of such publications and related documents with special emphasis on optimization of public exposure using dose constraints. (au)

  17. The dose-area product in DSA

    International Nuclear Information System (INIS)

    Gfirtner, H.

    1995-01-01

    In DSA, the dose-area product shows a very good correlation with the maximum incidence dose. It may therefore serve as a reliable basis for the assessment of radiation doses to patients. The dose-area product is also a useful tool for the detection pf peak shifts in the radiation curves for certain investigations. In view of the considerable scatter of the values for the dose-area product these must, however, be subjected to an additional statistical analysis. Provided that this rule is observed, the dose-area product will considerably gain in importance for the monitoring of radiation exposures of patients. A very noteworthy learning effect could be achieved, if it would be made mandatory for those statistical analyses to be carried out not only on an investigation-specific but also an investigator-specific basis. The latter is particularly true of teaching hospitals. (orig./VHE) [de

  18. Radiation doses in buildings containing coal

    International Nuclear Information System (INIS)

    Somlai, J.; Kanyar, B.; Nenyei, A.; Nemeth, Z.; Nemeth, Cs.

    2001-01-01

    Using coal-slag with high concentration of 226 Ra as building material could result excess dose of people living in these dwellings. The gamma dose rate, the radon concentration and the radionuclide concentration of built-in slags were measured in kindergartens, schools and homes of three towns (Ajka, Tatabanya, Varpalota). The absorbed dose rates exceeded significantly the world average (80 nGy/h) and the annual dose reached 3-4 mSv in some cases. The dose coming from radon is significant in the case of slags, which did not originate from power plants but from smaller stoves and furnaces because in these cases the burning temperature is lower, so the radon emanation is higher. The dose in the latter cases could reach 10-20 mSv/year. (author)

  19. Patient and staff dose during hysterosalpinography

    International Nuclear Information System (INIS)

    Buls, N.; Osteaux, M.

    2001-01-01

    Hysterosalpingography (HSG) is a useful and widely employed technique which uses X-ray fluoroscopy to investigate the female genital tract. Fluoroscopy is assessed by a gynaecologist, a physician who is not always trained to work with ionising radiation. Dose-area product measurements in a group of 34 patients allowed an estimation of the median effective dose (0,83 mSv) and the median dose to the ovaries (1,63 mGy) of the patient per procedure. The dose to the staff was estimated using thermoluminescent dosimetry. The following median entrance surface doses were estimated per procedure: 0,22 mGy to the lens of the eye, 0,15 mGy to the neck at thyroid level and 0,19 mGy to the back of the hand. The annual eye dose limit could be exceeded if the gynaecologist is a member of the public. (author)

  20. Analysis of workers' dose records from the Greek Dose Registry Information System

    International Nuclear Information System (INIS)

    Kamenopoulou, V.; Dimitriou, P.; Proukakis, Ch.

    1995-01-01

    The object of this work is the study of the individual film badge annual dose information of classified workers in Greece, monitored and assessed by the central dosimetry service of the Greek Atomic Energy Commission. Dose summaries were recorded and processed by the Dose Registry Information System. The statistical analysis refers to the years 1989-93 and deals with the distribution of individuals in the occupational groups, the mean annual dose, the collective dose, the distribution of the dose over the different specialties and the number of workers that have exceeded any of the established dose limits. Results concerning the annual dose summaries, demonstrate a year-by-year reduction in the mean individual dose to workers in the health sector. Conversely, exposures in the industrial sector did not show any decreasing tendency during the period under consideration. (Author)

  1. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    International Nuclear Information System (INIS)

    Li Heng; Li Yupeng; Zhang Xiaodong; Li Xiaoqiang; Liu Wei; Gillin, Michael T.; Zhu, X. Ronald

    2012-01-01

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove the principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a “pulsed beam”; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a “continuous beam.” A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose

  2. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  3. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  4. Characteristics of repair following very low doses

    International Nuclear Information System (INIS)

    Braby, L.A.; Metting, N.F.; Nelson, J.M.

    1987-01-01

    The effects of ionizing radiation on living systems being with the physical processes of energy deposition and develop through many stages of chemical reaction and biological response. The modeling effort attempts to organize the available data and theories of all of these stages into self-consistent models that can be compared and tested. In some cases, important differences among models result in only small differences in cell survival within the ranges of dose and dose rate that are normally investigated. To overcome this limitation, new ways of irradiating cells at extremes of dose rate, or ways of evaluating the effects of very small doses, are developed. Mathematical modeling and cellular studies complement each other. It has recently been found that some mechanisms are not adequate to account for the interaction of dose and repair time as they affect the reproductive survival of plateau-phase Chinese hamster ovary (CHO) cells. Repair of radiation-induced cellular damage plays a central role in the survival of cells exposed to doses of 1 Gy or more. This repair is responsible for the dose rate, split-dose and delayed plating effect and can be evaluated. Because split-dose and dose-rate experiments involve repair during irradiation and delayed plating experiments involve repair after irradiation is completed, it was originally thought that different repair processes were involved. It is now clear that this is not necessarily the case. Appropriately designed models can account for observed effects at conventional doses (1 Gy or more) whether they assume all damage is lethal unless repaired or some damage is innocuous unless it interacts with additional damage. The fact that the survival following a plating delay is always less than the survival following immediate plating at low doses indicates that the damage produced is probably not potentially lethal

  5. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  6. Hanford Environmental Dose Reconstruction Project monthly report

    International Nuclear Information System (INIS)

    Finch, S.M.

    1991-10-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doeses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): Source terms; environmental transport; environmental monitoring data; demographics, agriculture, food habits; environmental pathways and dose estimates

  7. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1988-01-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed

  8. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  9. Monitoring and dose recording for the individual

    International Nuclear Information System (INIS)

    1988-01-01

    This document specifies the conditions under which monitoring of individuals is required. For workers identified as Atomic Radiation Workers, determination of dose or exposure must be made. In circumstances where personal monitoring techniques are impractical, doses and exposures may be estimated by non-personal monitoring techniques. For workers not identified as Atomic Radiation Workers, licensees must be able to demonstrate that there is no reasonable potential for accumulating radiation doses or exposures in excess of regulatory limits. (L.L.)

  10. How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product.

    Science.gov (United States)

    Brady, Samuel L; Mirro, Amy E; Moore, Bria M; Kaufman, Robert A

    2015-05-01

    The purpose of this study is to show how to calculate effective dose in CT using size-specific dose estimates and to correct the current method using dose-length product (DLP). Data were analyzed from 352 chest and 241 abdominopelvic CT images. Size-specific dose estimate was used as a surrogate for organ dose in the chest and abdominopelvic regions. Organ doses were averaged by patient weight-based populations and were used to calculate effective dose by the International Commission on Radiological Protection (ICRP) report 103 method using tissue-weighting factors (EICRP). In addition, effective dose was calculated using population-averaged CT examination DLP for the chest and abdominopelvic region using published k-coefficients (EDLP = k × DLP). EDLP differed from EICRP by an average of 21% (1.4 vs 1.1) in the chest and 42% (2.4 vs 3.4) in the abdominopelvic region. The differences occurred because the published kcoefficients did not account for pitch factor other than unity, were derived using a 32-cm diameter CT dose index (CTDI) phantom for CT examinations of the pediatric body, and used ICRP 60 tissue-weighting factors. Once it was corrected for pitch factor, the appropriate size of CTDI phantom, and ICRP 103 tissue-weighting factors, EDLP improved in agreement with EICRP to better than 7% (1.4 vs 1.3) and 4% (2.4 vs 2.5) for chest and abdominopelvic regions, respectively. Current use of DLP to calculate effective dose was shown to be deficient because of the outdated means by which the k-coefficients were derived. This study shows a means to calculate EICRP using patient size-specific dose estimate and how to appropriately correct EDLP.

  11. SU-E-I-33: Advances in Dose Metrics and Dose Reduction Strategies for Interventional Fluoroscopy.

    Science.gov (United States)

    Weir, V; Zhang, J; Bruner, A

    2012-06-01

    To explore recent advances in available dose metrics and dose reduction features and their impacts during various fluoroscopy procedures. Besides traditional dose metrics (cumulative dose, DAP, etc), recent methods such as real time dose mapping and dose calculation from DICOM information and their relevance to entrance skin exposure (ESE) are demonstrated. Dose reduction features and their potential effects on ESE are explored for different interventional procedures, including dose setting options, frame rate settings, wedges, software options and how these help reduce patient dose, etc. Real time dose monitoring techniques such as DoseAware are investigated. Dose alert such as flagging higher doses at about half of the Joint Commission sentinel event limit, Dose Index Registry and their impacts are discussed. Habit related practices, such as a physician leaning over patients, are highlighted, also taking foot off the fluoroscopy pedal when not needed, and best places to stand are illustrated. A practice improvement procedure involving measurement, analysis and improvement actions is instituted. We also discuss the impact of physician follow up letters to patients who might not have reached the JC Sentinel Event limits but may still have skin issues. In our institutes, these efforts have led to reduction of both patient dose and personnel exposure for interventional procedures. The recording of technical parameters and fluoroscopy dose by the staff has led to a better understanding of appropriate dose levels and technique settings for each procedure. This article can serve as a refresher for radiological staff on how to protect patients and themselves from high doses, while providing the best care possible. It can also serve as criteria for health care providers to institute changes and make quality improvement in interventional practices. © 2012 American Association of Physicists in Medicine.

  12. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  13. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    Science.gov (United States)

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  14. Dose reconstruction modeling for medical radiation workers

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeong Chull; Cha, Eun Shil; Lee, Won Jin [Dept. of Preventive Medicine, Korea University, Seoul (Korea, Republic of)

    2017-04-15

    Exposure information is a crucial element for the assessment of health risk due to radiation. Radiation doses received by medical radiation workers have been collected and maintained by public registry since 1996. Since exposure levels in the remote past are greater concern, it is essential to reconstruct unmeasured doses in the past using known information. We developed retrodiction models for different groups of medical radiation workers and estimate individual past doses before 1996. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure.

  15. Fetal absorbed doses by radiopharmaceutical administration

    International Nuclear Information System (INIS)

    Rojo, Ana M; Gomez Parada, Ines M.; Di Trano, Jose L.

    2000-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author)

  16. Gamma dose estimation with the thermoluminescence method

    International Nuclear Information System (INIS)

    Kumamoto, Yoshikazu

    1994-01-01

    Absorbed dose in radiation accidents can be estimated with the aid of materials which have the ability of dose recording and were exposed during the accidents. Quartz in bricks and tiles used to construct the buildings has the thermoluminescent properties. These materials exposed to radiations emit light when heated. Quartz and ruby have been used for the estimation of dose. The requirements for such dosemeters include; (1)the high kiln temperature at which all thermoluminescent energies accrued from natural radiations are erased. (2)the negligible fading of thermoluminescent energies after the exposure to radiations. (3)the determination of dose from natural radiations after the making of the matcrials. (4)the geometry of the place at which materials are collected. Bricks or tiles are crushed in the motar, sieved into sizes, washed with HF, HCl, alchol, aceton and water, and given with a known calibration dose. The pre-dose method and high-temperature method are used. In the former, glow curves with and without calibration dose are recorded. In the latter, glow peaks at 110degC with and without calibration dose are recorded after the heating of quartz up to 500degC. In this report, the method of the sample preparation, the measurement procedures and the results of dose estimation in the atomic bombing, iridium-192 and Chernobyl accident are described. (author)

  17. Organ absorbed doses in intraoral dental radiography.

    Science.gov (United States)

    Lecomber, A R; Faulkner, K

    1993-11-01

    A dental radiography unit operating at 70 kV (nominal) and 20 cm focus-skin distance was used to irradiate an anthropomorphic phantom loaded with lithium fluoride thermoluminescent dosemeters, in order to assess the variation in organ absorbed dose with intraoral periapical radiographic view. 14 views using the bisecting-angle technique and four views using the paralleling technique were studied. The results are presented and the doses and dose distributions examined. Doses for the paralleling and bisecting-angle techniques are compared, and the effects of focus-skin distance and beam collimation upon patient dosimetry discussed. Sources of uncertainty in dental dosimetry studies using phantoms are also considered.

  18. In search of the relevant lung dose

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1982-12-01

    Researchers have traditionally been inconsistent in their methods of determining and reporting dose to the lung from inhaled radionuclides - a situation which has led to difficulties in later comparing results and deriving dose-response relationships. The dose quantities which at present are most generally assumed to be related to risk of stochastic radiation effects (such as lung cancer) are (1) mean dose equivalent to the bronchial epithelium basal cell layer for radon daughters, and (2) mean dose equivalent to the whole lung (including tracheobronchial lymph nodes) for all other radionuclides. The average radiation dose is calculated by assuming that the energy is homogeneously impared to the entire tissue mass. However, the actual dose received by a cell which becomes transformed or tumorigenic is likely to be very much different than the smear dose to the entire organ. This realization has led to further study of stochastic energy deposition processes in single cells or cell nuclei from internal emitters. The end product of the stochastic approach to dosimetry, sometimes called microdosimetry, is a probability density in specific energy. For alpha-emitting radionuclides in the lung, a concept that may be more important than dose is the probability that a cell is hit by an alpha particle

  19. Skin dose measurement with MICROSPEC-2 trademark

    International Nuclear Information System (INIS)

    Hsu, H.H.

    1997-01-01

    For many years, the Eberline HP-260 trademark beta detectors were used for skin dose measurements at Los Alamos National Laboratory. This detector does not measure the beta spectrum and the skin dose can only be determined if the contaminating radioactive isotope is known. A new product MICROSPEC-2 trademark, has been developed which consists of a small portable computer with a multichannel analyzer and a beta probe consisting of a phoswich detector. The system measures the beta spectrum and automatically folds in the beta fluence-to-dose conversion function to yield the skin dose

  20. Antiproton radiotherapy: peripheral dose from secondary neutrons

    DEFF Research Database (Denmark)

    Fahimian, Benjamin P.; DeMarco, John J.; Keyes, Roy

    2009-01-01

    is the normal tissue dose resulting from secondary neutrons produced in the annihilation of antiprotons on the nucleons of the target atoms. Here we present the first organ specific Monte Carlo calculations of normal tissue equivalent neutron dose in antiproton therapy through the use of a segmented CT......-based human phantom. The MCNPX Monte Carlo code was employed to quantify the peripheral dose for a cylindrical spread out Bragg peak representing a treatment volume of 1 cm diameter and 1 cm length in the frontal lobe of a segmented whole-body phantom of a 38 year old male. The secondary neutron organ dose...

  1. Hanford Environmental Dose Reconstruction Project monthly report

    International Nuclear Information System (INIS)

    Finch, S.M.

    1990-12-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have been have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demographics, agriculture, food habits; and environmental pathways and dose estimates. 3 figs., 3 tabs

  2. Dose reconstruction modeling for medical radiation workers

    International Nuclear Information System (INIS)

    Choi, Yeong Chull; Cha, Eun Shil; Lee, Won Jin

    2017-01-01

    Exposure information is a crucial element for the assessment of health risk due to radiation. Radiation doses received by medical radiation workers have been collected and maintained by public registry since 1996. Since exposure levels in the remote past are greater concern, it is essential to reconstruct unmeasured doses in the past using known information. We developed retrodiction models for different groups of medical radiation workers and estimate individual past doses before 1996. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure.

  3. Use of dose constraints for occupational exposure

    International Nuclear Information System (INIS)

    Kaijage, Tunu

    2015-02-01

    The use of dose constraints for occupational exposure was reviewed in this project. The role of dose constraints as used in optimization of protection of workers was described. Different issues to be considered in application of the concept and challenges associated with their implementation were also discussed. The situation where dose constraints could be misinterpreted to dose limits is also explained as the two are clearly differentiated by the International Commission of Radiological Protection (ICRP) Publication 103. Moreover, recommendations to all parties responsible for protection and safety of workers were discussed. (au)

  4. [Effective dose from pediatric CT in Iceland].

    Science.gov (United States)

    Gudjonsdottir, Jonina; Jonsdottir, Arna Bjork

    2017-11-01

    It is important to know the effective dose from computed tomography (CT) examinations. The aim of this study was to evaluate the effective dose from pediatric CT examinations in Iceland. For all pediatric CT exams (children examination type and dose length product was retrospectively collected from the Landspitali University Hospital's archives, as was the total number of CT examinations. The ratio of pediatric CT exams and the frequency of examination types were calculated and, for the three most common examinations, the effective dose and mean dose length product were calculated for five age groups. The total number of pediatric CT examinations was 662, 3,6% of all the CT examinations performed. The three most common pediatric CT examinations were head (40,3%), abdomen (15,6%) and thorax (10,3%). The mean effective dose in those was, in the above order: for children dose length product was above European diagnostic reference levels in most examination types and age groups. Possibilities for lower effective doses from pediatric CT examinations should be explored. For that purpose, the use of size specific dose estimates is recommended.

  5. Electron and bremsstrahlung penetration and dose calculation

    Science.gov (United States)

    Watts, J. W., Jr.; Burrell, M. O.

    1972-01-01

    Various techniques for the calculation of electron and bremsstrahlung dose deposition are described. Energy deposition, transmission, and reflection coefficients for electrons incident on plane slabs are presented, and methods for their use in electron dose calculations were developed. A method using the straight-ahead approximation was also developed, and the various methods were compared and found to be in good agreement. Both accurate and approximate methods of calculating bremsstrahlung dose were derived and compared. Approximation is found to give a good estimate of dose where the electron spectrum falls off exponentially with energy.

  6. Thermoluminescent dosimetry and assessment of personal dose

    International Nuclear Information System (INIS)

    Boas, J.F.; Martin, L.J.; Young, J.G.

    1982-01-01

    Thermoluminescence is discussed in terms of the energy band structure of a crystalline solid and the trapping of charge carriers by point defects. Some general properties of thermoluminescent materials used for dosimetry are outlined, with thermoluminescence of CaSO 4 :Dy being described in detail. The energy response function and the modification of the energy response of a dosimeter by shielding are discussed. The final section covers the connection between exposure, as recorded by a TLD badge, and the absorbed dose to various organs from gamma radiation in a uranium mine; the conversion from absorbed dose to dose equivalent; and uncertainties in assessment of dose equivalent

  7. Hanford Environmental Dose Reconstruction Project Monthly Report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M. (comp.)

    1991-03-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The project is divided into the technical tasks which correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environment monitoring data; demographics, agriculture, food habits; and environmental pathways and dose estimates. 3 figs., 2 tabs.

  8. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  9. Irrigation in dose assessments models

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Barkefors, Catarina [Studsvik RadWaste AB, Nykoeping (Sweden)

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  10. Irrigation in dose assessments models

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Barkefors, Catarina

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  11. Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic.

    Science.gov (United States)

    Poletti, Pierre-Alexandre; Platon, Alexandra; Rutschmann, Olivier T; Schmidlin, Franz R; Iselin, Christophe E; Becker, Christoph D

    2007-04-01

    The purpose of our study was to compare a low-dose abdominal CT protocol, delivering a dose of radiation close to the dose delivered by abdominal radiography, with standard-dose unenhanced CT in patients with suspected renal colic. One hundred twenty-five patients (87 men, 38 women; mean age, 45 years) who were admitted with suspected renal colic underwent both abdominal low-dose CT (30 mAs) and standard-dose CT (180 mAs). Low-dose CT and standard-dose CT were independently reviewed, in a delayed fashion, by two radiologists for the characterization of renal and ureteral calculi (location, size) and for indirect signs of renal colic (renal enlargement, pyeloureteral dilatation, periureteral or renal stranding). Results reported for low-dose CT, with regard to the patients' body mass indexes (BMIs), were compared with those obtained with standard-dose CT (reference standard). The presence of non-urinary tract-related disorders was also assessed. Informed consent was obtained from all patients. In patients with a BMI 3 mm. Low-dose CT was 100% sensitive and specific for depicting non-urinary tract-related disorders (n = 6). Low-dose CT achieves sensitivities and specificities close to those of standard-dose CT in assessing the diagnosis of renal colic, depicting ureteral calculi > 3 mm in patients with a BMI < 30, and correctly identifying alternative diagnoses.

  12. Multicriteria optimization of the spatial dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Schlaefer, Alexander [Medical Robotics Group, Universität zu Lübeck, Lübeck 23562, Germany and Institute of Medical Technology, Hamburg University of Technology, Hamburg 21073 (Germany); Viulet, Tiberiu [Medical Robotics Group, Universität zu Lübeck, Lübeck 23562 (Germany); Muacevic, Alexander; Fürweger, Christoph [European CyberKnife Center Munich, Munich 81377 (Germany)

    2013-12-15

    Purpose: Treatment planning for radiation therapy involves trade-offs with respect to different clinical goals. Typically, the dose distribution is evaluated based on few statistics and dose–volume histograms. Particularly for stereotactic treatments, the spatial dose distribution represents further criteria, e.g., when considering the gradient between subregions of volumes of interest. The authors have studied how to consider the spatial dose distribution using a multicriteria optimization approach.Methods: The authors have extended a stepwise multicriteria optimization approach to include criteria with respect to the local dose distribution. Based on a three-dimensional visualization of the dose the authors use a software tool allowing interaction with the dose distribution to map objectives with respect to its shape to a constrained optimization problem. Similarly, conflicting criteria are highlighted and the planner decides if and where to relax the shape of the dose distribution.Results: To demonstrate the potential of spatial multicriteria optimization, the tool was applied to a prostate and meningioma case. For the prostate case, local sparing of the rectal wall and shaping of a boost volume are achieved through local relaxations and while maintaining the remaining dose distribution. For the meningioma, target coverage is improved by compromising low dose conformality toward noncritical structures. A comparison of dose–volume histograms illustrates the importance of spatial information for achieving the trade-offs.Conclusions: The results show that it is possible to consider the location of conflicting criteria during treatment planning. Particularly, it is possible to conserve already achieved goals with respect to the dose distribution, to visualize potential trade-offs, and to relax constraints locally. Hence, the proposed approach facilitates a systematic exploration of the optimal shape of the dose distribution.

  13. Radiation dose-response of human tumors

    International Nuclear Information System (INIS)

    Okunieff, P.; Morgan, D.; Niemierko, Andrzej; Suit, H.D.

    1995-01-01

    The dose of radiation that locally controls human tumors treated electively or for gross disease is rarely well defined. These doses can be useful in understanding the dose requirements of novel therapies featuring inhomogeneous dosimetry and in an adjuvant setting. The goal of this study was to compute the dose of radiation that locally controls 50% (TCD 50 ) of tumors in human subjects. Logit regression was used with data collected from single institutions or from combinations of local control data accumulated from several institutions treating the same disease. 90 dose response curves were calculated: 62 of macroscopic tumor therapy, 28 of elective therapy with surgery for primary control. The mean and median TCD 50 for gross disease were 50.0 and 51.9 Gy, respectively. The mean and median TCD 50 for microscopic disease control were 39.3 and 37.9 Gy, respectively. At the TCD 50 , an additional dose of 1 Gy controlled an additional 2.5% (median) additional patients with macroscopic disease and 4.2% (median) additional patients with microscopic disease. For both macro- and microscopic disease, an increase of 1% of dose at the TCD 50 increased control rates ∼ 1% (median) or 2-3% (mean). A predominance of dose response curves had shallow slopes accounting for the discrepancy between mean and median values. Doses to control microscopic disease are approximately 12 Gy less than that required to control macroscopic disease and about 79% of the dose required to control macroscopic disease. The percentage increase in cures expected for a 1% increase in dose is similar for macroscopic and microscopic disease, with a median value of ∼ 1%/% and a mean of ∼ 2.7%/%. 94 refs., 4 figs., 6 tabs

  14. Multicriteria optimization of the spatial dose distribution

    International Nuclear Information System (INIS)

    Schlaefer, Alexander; Viulet, Tiberiu; Muacevic, Alexander; Fürweger, Christoph

    2013-01-01

    Purpose: Treatment planning for radiation therapy involves trade-offs with respect to different clinical goals. Typically, the dose distribution is evaluated based on few statistics and dose–volume histograms. Particularly for stereotactic treatments, the spatial dose distribution represents further criteria, e.g., when considering the gradient between subregions of volumes of interest. The authors have studied how to consider the spatial dose distribution using a multicriteria optimization approach.Methods: The authors have extended a stepwise multicriteria optimization approach to include criteria with respect to the local dose distribution. Based on a three-dimensional visualization of the dose the authors use a software tool allowing interaction with the dose distribution to map objectives with respect to its shape to a constrained optimization problem. Similarly, conflicting criteria are highlighted and the planner decides if and where to relax the shape of the dose distribution.Results: To demonstrate the potential of spatial multicriteria optimization, the tool was applied to a prostate and meningioma case. For the prostate case, local sparing of the rectal wall and shaping of a boost volume are achieved through local relaxations and while maintaining the remaining dose distribution. For the meningioma, target coverage is improved by compromising low dose conformality toward noncritical structures. A comparison of dose–volume histograms illustrates the importance of spatial information for achieving the trade-offs.Conclusions: The results show that it is possible to consider the location of conflicting criteria during treatment planning. Particularly, it is possible to conserve already achieved goals with respect to the dose distribution, to visualize potential trade-offs, and to relax constraints locally. Hence, the proposed approach facilitates a systematic exploration of the optimal shape of the dose distribution

  15. Organ dose and effective dose with the EOS scanner in spine deformity surgery

    DEFF Research Database (Denmark)

    Heide Pedersen, Peter; Petersen, Asger Greval; Eiskjær, Søren Peter

    2016-01-01

    Organ dose and effective dose with the EOS scanner in spine deformity surgery. A study on anthropomorphic phantoms describing patient radiation exposure in full spine examinations. Authors: Peter Heide Pedersen, Asger Greval Petersen, Søren Peter Eiskjær. Background: Ionizing radiation potentially...... quality images while at the same time reducing radiation dose. At our institution we use the EOS for pre- and postoperative full spine examinations. Purpose: The purpose of the study is to make first time organ dose and effective dose evaluations with micro-dose settings in full spine examinations. Our...... hypothesis is that organ dose and effective doses can be reduced 5-10 times compared to standard settings, without too high image-quality trade off, resulting in a theoretical reduction of radiation induced cancer. Methods: Patient dosimetry is performed on anthropomorphic child phantoms, representing a 5...

  16. Trends in doses to radiation workers recorded on the Central Index of Dose Information

    International Nuclear Information System (INIS)

    Greenslade, E.; Kendall, G.M.; Fillary, K.; Bines, W.P.

    1991-01-01

    This paper presents a preliminary analysis of the doses stored on the Central Index of Dose Information for the calendar years 1986, 1987 and 1988. Mean doses are low, and both mean doses and the proportion of workers exceeding 15 mSv in a year are decreasing with time. Underground miners are the occupational group receiving the highest doses, though in this and other relatively high dose groups the exposures are falling with time. Only 6% of workers are female and their average individual dose is about half that of men. Patterns of employment are different for women and men but there is a tendency for women to receive lower doses than men even within the same occupation. (author)

  17. The role of variability of dose in dose-response relationships for alpha emitting radionuclides

    International Nuclear Information System (INIS)

    Crawford-Brown, D.J.; Hofmann, W.

    1989-01-01

    Radiation protection requires predictions of the effects of radiation at low mean organ doses. Since epidemiological data are restricted to moderate to high doses, extrapolation functions must be developed. The present paper derives such a function from theoretical considerations of the ability of radiation to initiate, promote and kill cells. The resulting function, however, is unable to account for the continued increase in cancer incidence amongst uranium miners and 224 Ra cases at mean organ doses of several tens of grays. This failure is ascribed to the use of mean organ dose as an appropriate variable in dose-response equations. By an explicit incorporation of variability in cellular doses, the model developed here is shown to display the general features of the epidemiological data when model parameters are made consistent with findings from cellular radiobiology. This indicates that variability of cellular dose may play an essential role in determining the shape of epidemiologically based dose-response curves. (author)

  18. An updated dose assessment for Rongelap Island

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W.L.; Conrado, C.L.; Bogen, K.T.

    1994-07-01

    We have updated the radiological dose assessment for Rongelap Island at Rongelap Atoll using data generated from field trips to the atoll during 1986 through 1993. The data base used for this dose assessment is ten fold greater than that available for the 1982 assessment. Details of each data base are presented along with details about the methods used to calculate the dose from each exposure pathway. The doses are calculated for a resettlement date of January 1, 1995. The maximum annual effective dose is 0.26 mSv y{sup {minus}1} (26 mrem y{sup {minus}1}). The estimated 30-, 50-, and 70-y integral effective doses are 0.0059 Sv (0.59 rem), 0.0082 Sv (0.82 rem), and 0.0097 Sv (0.97 rem), respectively. More than 95% of these estimated doses are due to 137-Cesium ({sup 137}Cs). About 1.5% of the estimated dose is contributed by 90-Strontium ({sup 90}Sr), and about the same amount each by 239+240-Plutonium ({sup 239+240}PU), and 241-Americium ({sup 241}Am).

  19. Estimation of radiation risks at low dose

    International Nuclear Information System (INIS)

    1990-04-01

    The report presents a review of the effects caused by radiation in low doses, or at low dose rates. For the inheritable (or ''genetic''), as well as for the cancer producing effects of radiation, present evidence is consistent with: (a) a non-linear relationship between the frequency of at least some forms of these effects, with comparing frequencies caused by doses many times those received annually from natural sources, with those caused by lower doses; (b) a probably linear relationship, however, between dose and frequency of effects for dose rates in the region of that received from natural sources, or at several times this rate; (c) no evidence to indicate the existence of a threshold dose below which such effects are not produced, and a strong inference from the mode of action of radiation on cells at low dose rates that no such thresholds are likely to apply to the detrimental, cancer-producing or inheritable, effects resulting from unrepaired damage to single cells. 19 refs

  20. Verification of Entrance Dose Measurements with ...

    African Journals Online (AJOL)

    TLD system at the Radiation Monitoring and. Protection Centre, Lagos State University, Ojo, Lagos‑Nigeria was used for the in vivo entrance dose readings. All patients were treated with Co‑60 (T780c) ... and to determine the influence of shape, size, and density variations of the body of the patient on the dose calculation.

  1. Computed tomography dose assessment - a practical approach

    International Nuclear Information System (INIS)

    Leitz, W.; Szendro, G.; Axelsson, B.

    1995-01-01

    A survey of the pattern and frequency of computed tomography (CT) examinations in Sweden has been conducted covering 89 of the 90 existing CT scanners (in 1991). The radiation output and the absorbed doses in phantoms have been measured for all types of CT scanners. For the assessment of the effective dose to the patient a new, practical approach has been developed. The average absorbed doses measured in cylindrical PMMA phantoms were assumed to be valid also for patients, those in the 320 mm diameter phantom for the trunk region and those in the 160 mm diameter phantom for the neck and head. With guidance from the ICRP 60 concept of tissue weighting factors, average weighting factors were adopted for the trunk, the neck, and the head region. Effective patient doses were calculated using three factors for doses measured in phantoms with the settings of exposure parameters as recorded in the survey. The results were compared with dose evaluations based on Monte Carlo calculations. The agreement was found to be satisfactory. It is suggested that this new practical approach should be adopted as a standard method for the assessment of effective dose in CT practices thus enabling direct access to dose evaluations in daily clinical practice -a prerequisite for the implementation of radiation protection concepts into the radiological society. (Author)

  2. Absorbed radiation dose on LHC interconnects

    CERN Document Server

    Versaci, R; Vlachoudis, V; CERN. Geneva. ATS Department

    2011-01-01

    Here we present the results of our FLUKA simulations devoted to the evaluation of the peak dose absorbed by the busbar insulator in the LHC Interaction Region 7 interconnects. The peak dose absorbed by the cold magnet coils are also presented.

  3. Total Dose Survivability of Hubble Electronic Components

    Science.gov (United States)

    Xapsos, M. A.; Stauffer, C.; Jordan, T.; Poivey, C.; Haskins, D. N.; Lum, G.; Pergosky, A. M.; Smith, D. C.; LaBel, K. A.

    2017-01-01

    A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.

  4. Effects of low doses: Proof and inferences

    International Nuclear Information System (INIS)

    Hubert, Ph.

    2010-01-01

    It is essential to discuss the plausibility of 'low-dose' effects from environmental exposures. The question, nonetheless, is wrongly labelled, for it is not the magnitude of the dose that matters, but rather the effect. The question thus concerns 'doses with low effects'. More precisely, because the low effects on large populations are not that small, even when epidemiological tools fail to detect them, it would be more accurate to talk about 'doses with undetectable or barely detectable effects'. Hereafter, we describe this 'low-effect dose' concept from the viewpoint of toxicology and epidemiology and discuss the fragile boundary line for these low-effect doses. Next, we review the different types of inference from observed situations (i.e., with high effects) to situations relevant to public health, to characterize the level of confidence to be accorded them. The first type is extrapolation - from higher to lower doses or from higher to lower dose rates. The second type is transposition - from humans to other humans or from animals to humans. The third type can be called 'analogy' as in 'read across' approaches, where QSAR (Quantitative Structure Activity Relationship) methodology can be used. These three types of inferences can be based on an estimate of the 'distance' between observed and predicted areas, but can also rely on knowledge and theories of the relevant mechanisms. The new tools of predictive toxicology are helpful both in deriving quantitative estimates and grounding inferences on sound bases. (author)

  5. Topology optimization of inertia driven dosing units

    DEFF Research Database (Denmark)

    Andreasen, Casper Schousboe

    2017-01-01

    to the Brinkman penalized Navier-Stokes equation the design of the dosing units can be optimized with respect to dosing capability without initial design assumptions. The influence of flow resistance and speed is investigated to assess design performance under varying operating conditions....

  6. Low dose intravaginal misoprostol versus intracervical balloon ...

    African Journals Online (AJOL)

    Background:The efficacy and safety of low dose misoprostol as a ripening agent compared to the widely used balloon catheter in developing countries is undetermined. Objective:To compare the safety and efficacy of a low dose intravaginal misoprostol and intracervical Foley's catheter for cervical ripening. Design:A ...

  7. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D. [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  8. Patient radiation doses from neuroradiology procedures

    International Nuclear Information System (INIS)

    Garcia-Roman, M.J.; Abreu-Luis, J.; Hernandez-Armas, J.; Prada-Martinez, E.

    2001-01-01

    Following the presentation of radiation-induced deterministic effects by some patients undergoing neuroradiological procedures during successive sessions, such as temporary epilation, in the 'Hospital Universitario de Canarias', measurements were made of dose to patients. The maximum dose-area product measured by ionization chamber during these procedures was 39617 cGy.cm 2 in a diagnostic of aneurysm and the maximum dose to the skin measured by thermoluminescent dosemeters (TLDs) was 462.53 mGy. This can justify certain deterministic effects but it is unlikely that the patients will suffer serious effects from this skin dose. Also, measurements were made of effective dose about two usual procedures, embolisation of tumour und embolisation of aneurysm. These procedures were reproduced with an anthropomorphic phantom Rando and doses were measured with TLDs. Effective doses obtained were 3.79 mSv and 4.11 mSv, respectively. The effective dose valued by the program EFFDOSE was less than values measured with TLDs. (author)

  9. Surface dose in intracavitary orthovoltage radiotherapy

    International Nuclear Information System (INIS)

    Podgorsak, M.B.; Schreiner, L.J.; Podgorsak, E.B.

    1990-01-01

    Radiotherapy with orthovoltage techniques is often the prime treatment for localized superficial malignancies. Surface doses and depth doses measured with cylindrical and end-window Farmer chambers are presented for various orthovoltage x-ray beams in the range from 80 to 300 kVp, both for open beams and beams collimated with commercial intracavitary leaded-glass cones. For radiation fields collimated by a diaphragm positioned at a distance from the patient surface (open beams) there is a small skin-sparing effect. On the other hand, the surface doses with commercial leaded-glass intracavitary cones can exhibit a fivefold increase compared to the open-beam dose maxima. Beyond a depth of ∼0.2 mm in a tissue-equivalent phantom, the doses measured for open beams and beams collimated with intracavitary cones are essentially identical. The increase in the surface dose observed with intracavitary cones is attributed to photoelectrons and recoil electrons produced in the cones. The high surface doses are measured by thin-wall parallel-plate ionization chambers but cannot be measured with cylindrical Farmer chambers since these chambers have wall thicknesses too large for the transmission of electrons produced in the cone. Since cylindrical Farmer chambers are typically used for calibration of radiation output, the high surface doses produced by the intracavitary cones may be overlooked; they can, however, be reduced to open-beam values by simple modifications to the cones

  10. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  11. Methods of bone marrow dose calculation

    International Nuclear Information System (INIS)

    Taboaco, R.C.

    1982-02-01

    Several methods of bone marrow dose calculation for photon irradiation were analised. After a critical analysis, the author proposes the adoption, by the Instituto de Radioprotecao e Dosimetria/CNEN, of Rosenstein's method for dose calculations in Radiodiagnostic examinations and Kramer's method in case of occupational irradiation. It was verified by Eckerman and Simpson that for monoenergetic gamma emitters uniformly distributed within the bone mineral of the skeleton the dose in the bone surface can be several times higher than dose in skeleton. In this way, is also proposed the Calculation of tissue-air ratios for bone surfaces in some irradiation geometries and photon energies to be included in the Rosenstein's method for organ dose calculation in Radiodiagnostic examinations. (Author) [pt

  12. Radiation doses to patients in haemodynamic procedures

    International Nuclear Information System (INIS)

    Canadillas-Perdomo, B.; Catalan-Acosta, A.; Hernandez-Armas, J.; Perez-Martin, C.; Armas-Trujillo, D. de

    2001-01-01

    Interventional radio-cardiology gives high doses to patients due to high values of fluoroscopy times and large series of radiographic images. The main objective of the present work is the determination of de dose-area product (DAP) in patients of three different types of cardiology procedures with X-rays. The effective doses were estimated trough the organ doses values measured with thermoluminescent dosimeters (TLDs-100), suitable calibrated, placed in a phantom type Rando which was submitted to the same radiological conditions corresponding to the procedures made on patients. The values for the effective doses in the procedures CAD Seldinger was 6.20 mSv on average and 1.85mSv for pacemaker implants. (author)

  13. Occupational dose at Rokkasho reprocessing plant (RRP)

    International Nuclear Information System (INIS)

    Takashima, F.; Taguchi, R.; Kano, M.; Moriyama, T.; Ogaki, K.; Noda, K.

    2008-01-01

    In Japan, Rokkasho Reprocessing Plant (RRP) is going to start the operation in service as the first large-scale commercial reprocessing plant of spent fuels that has annual reprocessing quantity of 800tU pr in maximum. The occupational external exposure is controlled for the purpose of keeping dose as low as reasonably achievable, and it is monitored by the personal dosimeter. On the other hand, the occupational internal exposure is controlled for the purpose of preventing, and it is monitored by the periodical evaluation of internal dose from the radioactive concentration in air of workplace. The individual doses of radiation workers are less than the dose limits in the statute and our lower management values enough. Dose data will be stored continuously and the rational management method will be examined. (author)

  14. Dose computation for therapeutic electron beams

    Science.gov (United States)

    Glegg, Martin Mackenzie

    The accuracy of electron dose calculations performed by two commercially available treatment planning computers, Varian Cadplan and Helax TMS, has been assessed. Measured values of absorbed dose delivered by a Varian 2100C linear accelerator, under a wide variety of irradiation conditions, were compared with doses calculated by the treatment planning computers. Much of the motivation for this work was provided by a requirement to verify the accuracy of calculated electron dose distributions in situations encountered clinically at Glasgow's Beatson Oncology Centre. Calculated dose distributions are required in a significant minority of electron treatments, usually in cases involving treatment to the head and neck. Here, therapeutic electron beams are subject to factors which may cause non-uniformity in the distribution of dose, and which may complicate the calculation of dose. The beam shape is often irregular, the beam may enter the patient at an oblique angle or at an extended source to skin distance (SSD), tissue inhomogeneities can alter the dose distribution, and tissue equivalent material (such as wax) may be added to reduce dose to critical organs. Technological advances have allowed the current generation of treatment planning computers to implement dose calculation algorithms with the ability to model electron beams in these complex situations. These calculations have, however, yet to be verified by measurement. This work has assessed the accuracy of calculations in a number of specific instances. Chapter two contains a comparison of measured and calculated planar electron isodose distributions. Three situations were considered: oblique incidence, incidence on an irregular surface (such as that which would be arise from the use of wax to reduce dose to spinal cord), and incidence on a phantom containing a small air cavity. Calculations were compared with measurements made by thermoluminescent dosimetry (TLD) in a WTe electron solid water phantom. Chapter

  15. The national dose registry of Canada

    International Nuclear Information System (INIS)

    1982-04-01

    In 1951, when the National Dosimetry Service was established by the Department of National Health and Welfare, a system of centralized records was created as an integral part of the new service. Over the last few years the dose record system has expanded in size and content, and improvements have been made in the physical methods of record storage. In addition to the 250 000 individual dose records from the National Dosimetry Service, the National Dose Registry now includes internal tritium and external doses from nuclear generating stations, and radon daughter exposures submitted by uranium mining companies. With the increase in the use of radiation in the medical, industrial and research fields, it is becoming more important to have a comprehensive and readily accessible centralized record system. The Canadian National Dose Registry is particularly suited for continuing health risk studies of radiation workers and provides a base for future epidemiological studies

  16. Absorbed dose uncertainty estimation for proton therapy

    Directory of Open Access Journals (Sweden)

    Spasić-Jokić Vesna

    2012-01-01

    Full Text Available Successful radiotherapy treatment depends on the absorbed dose evaluation and the possibility to define metrological characteristics of the therapy beam. Radiotherapy requires tumor dose delivery with expanded uncertainty less than ±5 %. It is particularly important to reduce uncertainty during therapy beam calibration as well as to apply all necessary ionization chamber correction factors. Absorbed dose to water was determined using ionometric method. Calibration was performed in reference cobalt beam. Combined standard uncertainty of the calculated absorbed dose to water in 65 MeV proton beam was ±1.97% while the obtained expanded uncertainty of absorbed dose for the same beam quality was ±5.02%. The uncertainty estimation method has been developed within the project TESLA.

  17. Radiation Dose Measurement Using Chemical Dosimeters

    International Nuclear Information System (INIS)

    Lee, Min Sun; Kim, Eun Hee; Kim, Yu Ri; Han, Bum Soo

    2010-01-01

    The radiation dose can be estimated in various ways. Dose estimates can be obtained by either experiment or theoretical analysis. In experiments, radiation impact is assessed by measuring any change caused by energy deposition to the exposed matter, in terms of energy state (physical change), chemical production (chemical change) or biological abnormality (biological change). The chemical dosimetry is based on the implication that the energy deposited to the matter can be inferred from the consequential change in chemical production. The chemical dosimetry usually works on the sample that is an aqueous solution, a biological matter, or an organic substance. In this study, we estimated absorbed doses by quantitating chemical changes in matter caused by radiation exposure. Two different chemical dosimeters, Fricke and ECB (Ethanol-Chlorobenzene) dosimeter, were compared in several features including efficacy as dose indicator and effective dose range

  18. Hanford Environmental Dose Reconstruction Project Monthly Report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M. (comp.)

    1990-05-01

    This monthly report summarizes the technical progress and project status for the Hanford Environmental Dose Reconstruction (HEDR) Project being conducted at Pacific Northwest Laboratory (PNL) under the direction of a Technical Steering Panel (TSP). The TSP is composed of experts in numerous technical fields related to this project and represents the interests of the public. The US Department of Energy (DOE) funds the project. The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is divided into the following technical tasks. These tasks address each of the primary steps in the path from radioactive releases to dose estimates source terms, environmental transport, environmental monitoring data, demographics, agriculture, and food habits, and environmental pathways and dose estimates.

  19. Hanford Environmental Dose Reconstruction Project Monthly Report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S.M. (comp.)

    1990-06-01

    This monthly report summarizes the technical progress and project status for the Hanford Environmental Dose Reconstruction (HEDR) Project being conducted at Pacific Northwest Laboratory (PNL) under the direction of a Technical Steering Panel (TSP). The TSP is composed of experts in numerous technical fields related to this project and represents the interests of the public. The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is divided into technical tasks which address each of the primary steps in the path from radioactive releases to dose estimates: source terms, environmental transport, environmental monitoring data, demographics, agriculture, and food habits, and environmental pathways and dose estimates.

  20. Dose reduction at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.; Dionne, B.J.

    1983-01-01

    The collective dose equivalent at nuclear power plants increased from 1250 rem in 1969 to nearly 54,000 rem in 1980. This rise is attributable primarily to an increase in nuclear generated power from 1289 MW-y to 29,155 MW-y; and secondly, to increased average plant age. However, considerable variation in exposure occurs from plant to plant depending on plant type, refueling, maintenance, etc. In order to understand the factors influencing these differences, an investigation was initiated to study dose-reduction techniques and effectiveness of as low as reasonably achievable (ALARA) planning at light water plants. Objectives are to: identify high-dose maintenance tasks and related dose-reduction techniques; investigate utilization of high-reliability, low-maintenance equipment; recommend improved radioactive waste handling equipment and procedures; examine incentives for dose reduction; and compile an ALARA handbook

  1. Intracavitary radiation treatment planning and dose evaluation

    International Nuclear Information System (INIS)

    Anderson, L.L.; Masterson, M.E.; Nori, D.

    1987-01-01

    Intracavitary radiation therapy with encapsulated radionuclide sources has generally involved, since the advent of afterloading techniques, inserting the sources in tubing previously positioned within a body cavity near the region to be treated. Because of the constraints on source locations relative to the target region, the functions of treatment planning and dose evaluation, usually clearly separable in interstitial brachytherapy, tend to merge in intracavitary therapy. Dose evaluation is typically performed for multiple source-strength configurations in the process of planning and thus may be regarded as complete when a particular configuration has been selected. The input data for each dose evaluation, of course, must include reliable dose distribution information for the source-applicator combinations used. Ultimately, the goal is to discover the source-strength configuration that results in the closest possible approach to the dose distribution desired

  2. Measurement of vocal doses in virtual classrooms

    DEFF Research Database (Denmark)

    Bottalico, Pasquale; Pelegrin Garcia, David

    2010-01-01

    different acoustical conditions, that combined different kind of background noise and virtual classroom acoustics. Readings from the vocal fold vibrations were registered with an Ambulatory Phonation Monitor device. The speech signal from the talker in the center of the facility was picked up with a head...... with an artificial head (corresponding to the mouth-ears path) placed at the talker position while simulating the classrooms. Time histories of the vocal fold vibration readings, with the trend of the fundamental frequency and an estimation of the sound pressure level, sampled every 50 ms, were obtained. From...... these data the vocal doses Time dose, Vocal Loading Index, Distance Dose, Energy Dissipation Dose, and Radiated Energy Dose were calculated and correlated with the acoustical features of the classrooms....

  3. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents

    NARCIS (Netherlands)

    E. Chatelut (Etienne); M.L. White-Koning (M.); A.H.J. Mathijssen (Ron); F. Puisset (F.); S.D. Baker (Sharyn); A. Sparreboom (Alex)

    2012-01-01

    textabstractBackground: Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patients dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main

  4. Optimizing dose prescription in stereotactic body radiotherapy for lung tumours using Monte Carlo dose calculation

    NARCIS (Netherlands)

    Widder, Joachim; Hollander, Miranda; Ubbels, Jan F.; Bolt, Rene A.; Langendijk, Johannes A.

    Purpose: To define a method of dose prescription employing Monte Carlo (MC) dose calculation in stereotactic body radiotherapy (SBRT) for lung tumours aiming at a dose as low as possible outside of the PTV. Methods and materials: Six typical T1 lung tumours - three small, three large - were

  5. Effect of Residential Radon Decay Product Dose Factor Variability on Reporting of Dose.

    Science.gov (United States)

    Harley, Naomi H

    2018-04-01

    Guidelines for occupational exposure to radiation are based on annual absorbed or effective dose. Guidelines for Rn exposure are currently based on air concentrations of Rn or decay products. Models of bronchial dose from decay product exposure are based on calculations that have five major parameters with parameter variabilities ranging from 20 to 50%. Many countries currently use the ICRP dose conversion convention, which is a ratio of lifetime Rn lung cancer risk to lifetime atomic bomb dose risk. The results of ongoing epidemiology changed both lifetime risk values, and the dose conversion convention has increased by a factor of 2. Therefore, the current dose conversion convention risk ratio is to be replaced by biokinetic dosimetric models. The main effect of variability in the value of Rn dose factors on industry is that the workplace atmosphere must be characterized accurately, and at present, this is not possible. A history of the dose factor models is central to factor development. The values of the dose model parameters are described illustrating the difficulty in calculation of a dose factor with universal applicability. The objective is to show the range of each parameter and the effect of the dose factor used when reporting occupational or residential bronchial dose.

  6. Effect of dose and dosing rate on the mutagenesis of nitric oxide in ...

    African Journals Online (AJOL)

    Purpose: To determine how the dose and rate of NO• treatment affects mutagenic responses. Methods: Shuttle vector ... Conclusion: These results provide important clues to how dose and dosing rate of introducing NO• may contribute to potential ..... Arroyo PL, Hatch-Pigott V, Mower HF, Cooney RV. Mutagenicity of nitric ...

  7. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  8. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  9. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  10. Insucessos em empreendimentos nucleares devido a falhas em processos de Comunicação Pública

    Directory of Open Access Journals (Sweden)

    Vinícius V. M. Ferreira

    Full Text Available A energia nuclear é um tema amplamente discutido em todo o mundo. O acidente nuclear de Chernobyl e o acidente radiológico de Goiânia contribuíram decisivamente para que a sociedade brasileira tivesse uma imagem negativa sobre o tema. A operação da usina de Angra 3, atualmente em obras, está vinculada à construção de um repositório para armazenar os rejeitos radioativos, o que provavelmente será explorado pelos opositores do setor nuclear. Um dos grandes desafios dos profissionais envolvidos nesse tipo de construção não é a engenharia em si, mas sim a aceitação pública do projeto, em razão do receio da sociedade sobre esse tema. O objetivo do estudo é levantar e apresentar experiências internacionais e nacionais sobre a aceitação pública de empreendimentos nucleares, com foco nos repositórios de rejeitos radioativos onde houve insucessos em razão de falhas nos processos de Comunicação Pública. É importante conhecer também os insucessos, de modo a não incorrer em erros semelhantes.

  11. Falhas de estruturas de aço soldadas devido a reduzida ductilidade

    Directory of Open Access Journals (Sweden)

    Ivan Guerra Machado

    2013-12-01

    Full Text Available O principal propósito deste artigo é demonstrar para os (as engenheiros(as projetistas e de soldagem, que numa estrutura de aço estrutural soldada a ductilidade possui importância equivalente ou ainda maior do que a resistência e a rigidez. Porém, o elevado nível requerido para a ductilidade não pode ser somente dos metais base e de solda. A análise tem que ser abrangente, envolvendo todos os componentes e também a estrutura completa.

  12. Georgia fishery study: implications for dose calculations

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1983-01-01

    Fish consumption will contribute a major portion of the estimated individual and population doses from L-Reactor liquid releases and Cs-137 remobilization in Steel Creek. It is therefore important that the values for fish consumption used in dose calculations be as realistic as possible. Since publication of the L-Reactor Environmental Information Document (EID), data have become available on sport fishing in the Savannah River. These data provide SRP with site-specific sport fish harvest and consumption values for use in dose calculations. The Georgia fishery data support the total population fish consumption and calculated dose reported in the EID. The data indicate, however, that both the EID average and maximum individual fish consumption have been underestimated, although each to a different degree. The average fish consumption value used in the EID is approximately 3% below the lower limit of the fish consumption range calculated using the Georgia data. A fish consumption value of 11.3 kg/yr should be used to recalculate dose to the average individual from L-Reactor restart. Maximum fish consumption in the EID has been underestimated by approximately 60%, and doses to the maximum individual should also be recalculated. Future dose calculations should utilize an average fish consumption value of 11.3 kg/yr, and a maximum fish consumption value of 34 kg/yr

  13. Low doses of gamma radiation in soybean

    Energy Technology Data Exchange (ETDEWEB)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C., E-mail: zegilmar60@gmail.com, E-mail: gilmita@uol.com.br, E-mail: villavic@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Caio H. [Universidade Federal de São Paulo (UNIFESP), SP (Brazil). Departamento de Microbiologia, Imunologia e Parasitologia

    2017-07-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  14. The use of dose constraints concept

    International Nuclear Information System (INIS)

    Dina, Dumitru; Andrei, Veronica; Glodeanu, Florin; Goicea, Andrei

    2003-01-01

    The 1990 Recommendations of the International Commission on Radiological Protection (ICRP Publication 60) explicitly introduced the concept of 'dose constraints' within the context of optimization of protection. The concept was not new and the meaning of its introduction was an attempt to consolidate and rationalize various concepts already existing in the ICRP guidance. In Romania the Order of National Commission for Control of Nuclear Activities - CNCAN no. 14/2000, for approval of the Fundamental Regulations for Radiological Safety, may impose the use of dose constraints for practices or for specific radiation sources inside the practices when required. Dose constraints would be used like upper bound in radioprotection optimization. The use of dose constraints is not an easy task because the understanding and interpretation of its meaning and application in the regulatory and operational practice is still under development. For operation of Cernavoda Nuclear Power Plant - Unit 1 as well as in the implementation of the new Interim Spent Fuel Dry Storage Facility project the dose constraints concept was used in the licensing process. On this basis the authorized dose limit and legal dose limit concepts became clearer and would be used within the documents. (authors)

  15. Patient doses from chest radiography in Victoria

    International Nuclear Information System (INIS)

    Cardillo, I.; Boal, T.J.; Einsiedel, P.F.

    1997-01-01

    This survey examines doses from posterior-anterior projection (PA) chest radiography at radiology practices, private hospitals and public hospitals throughout metropolitan and country Victoria. Data were collected from 111 individual X-ray units at 86 different practices. Entrance skin doses in air were measured for exposure factors used by the centre for a 23 cm thick male chest. A CDRH LucAl chest phantom was used when making these measurements. About half of the centres used grid technique and half used non-grid technique. There was a factor of greater than 10 difference in the entrance dose delivered between the highest dose centre and the lowest dose centre for nongrid centres; and a factor of about 5 for centres using grids. Factors contributing to the high doses recorded at some centres were identified. Guidance levels for chest radiography based on the third quartile value of the entrance doses from this survey have been recommended and compared with guidance levels recommended in other countries. (authors)

  16. Topical Metered-dosing Dispenser Performance Evaluation.

    Science.gov (United States)

    Liu, Qiang; Kupiec, Thomas C; Vu, Nicole T

    2016-01-01

    Topical metered-dosing dispensers are designed for dosing accuracy and ease-of-use by the patients while protecting the packaged products from environmental exposure and contamination. The objective of this study was to evaluate the accuracy, precision, and residual of available topical metered-dosing dispensers with different types of topical cream for practical application. Triplicate samples of five different dispensers were tested. This test was completed using three types of commercial topical cream-bases of dissimilar Total Active Pharmaceutical Ingredient Load Percentages, Transdermal Penetration Percentages, and Specific Gravities. The dispensers were evaluated according to specified dose-uniformity criteria for a total dispensing capacity of 30 mL at 0.5 mL per dose for 60 doses. The study shows Topi-CLICK performed with the best precision and accuracy of dosing in comparison to the airless-pump type dispensers. While the dispensing was highly variable with airless pumps and may require calibration for each packaged product, remarkably the performance of Topi-CLICK was not affected by different types of cream-bases and does not require additional metering calibration. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  17. Dose profile of a dental facilities

    International Nuclear Information System (INIS)

    Silva Borges, D. da; Lava, D.D.; Moreira, M. de L.; Ferreira Guimaraes, A.C.; Silva, L. Fernandes da

    2015-01-01

    The determination of the dose profile is important to classify the level of danger which the individuals are exposed (considering their positioning) in dental facilities. From this, this paper aims to present a methodology capable of mapping the dose within dental rooms in three dimensions. The methodology used for dose mapping in conjunction with techniques for calculating shielding for dental facilities, provided by the National Council on Radiation Protection and Measurements (NCRP), form a complete system able to generate meaningful data on the safety of occupationally Exposed Individuals (IOEs) and of the public. As the dose is strongly dependent on the distance, the estimated value of the initial dose was made in the isocenter of the source. This value was adopted because the model of dose calculus tends to infinity when it is desired to analyze points very close of the source. The model of room to be presented, as a case of illustration of the methodology, was arbitrarily constructed to generate better understanding of the problem. Its inclusion in the calculus was made through discretizations performed with the aid of high-performance computers. This discretizations allowed the obtain of dose values for an infinitesimal distance after the start point. (authors)

  18. Dose assessment for brachytherapy with Henschke applicator

    International Nuclear Information System (INIS)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Tung, Chuan-Jong; Wu, Ching-Jung; Lee, Chung-Chi

    2011-01-01

    Dose perturbation caused by the Henschke applicator is a major concern for the brachytherapy planning system (BPS) in recent years. To investigate dose impact owing to neglect of the metal shielding effect, Monte Carlo (MC) simulation, BPS calculation, and film measurement have been performed for dose assessment in a water phantom. Additionally, a cylindrical air cavity representing the rectum was added into the MC simulation to study its effect on dose distribution. Monte Carlo N-Particle Transport Code (MCNP) was used in this study to simulate the dose distribution using a mesh tally. This Monte Carlo simulation has been validated using the TG-43 data in a previous report. For the measurement, the Henschke applicator was placed in a specially-designed phantom, and Gafchromic films were inserted in the center plane for 2D dose assessment. Isodose distributions with and without the Henschke applicator by the MC simulation show significant deviation from those by the BPS. For MC simulation, the isodose curves shrank more significantly when the metal applicator was applied. For the impact of the added air cavity, the results indicate that it is hard to distinguish between with and without the cavity. Thus, the rectum cavity has little impact on the dose distribution around the Henschke applicator.

  19. Low doses of gamma radiation in soybean

    International Nuclear Information System (INIS)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C.; Arthur, Valter; Arthur, Paula B.; Franco, Caio H.

    2017-01-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  20. Derivation of dose conversion factors for tritium

    International Nuclear Information System (INIS)

    Killough, G.G.

    1982-03-01

    For a given intake mode (ingestion, inhalation, absorption through the skin), a dose conversion factor (DCF) is the committed dose equivalent to a specified organ of an individual per unit intake of a radionuclide. One also may consider the effective dose commitment per unit intake, which is a weighted average of organ-specific DCFs, with weights proportional to risks associated with stochastic radiation-induced fatal health effects, as defined by Publication 26 of the International Commission on Radiological Protection (ICRP). This report derives and tabulates organ-specific dose conversion factors and the effective dose commitment per unit intake of tritium. These factors are based on a steady-state model of hydrogen in the tissues of ICRP's Reference Man (ICRP Publication 23) and equilibrium of specific activities between body water and other tissues. The results differ by 27 to 33% from the estimate on which ICRP Publication 30 recommendations are based. The report also examines a dynamic model of tritium retention in body water, mineral bone, and two compartments representing organically-bound hydrogen. This model is compared with data from human subjects who were observed for extended periods. The manner of combining the dose conversion factors with measured or model-predicted levels of contamination in man's exposure media (air, drinking water, soil moisture) to estimate dose rate to an individual is briefly discussed

  1. Radiation dose optimization in thoracic imaging.

    Science.gov (United States)

    Tack, D

    2010-01-01

    Guidelines for reduction of CT radiation dose were introduced in 1997 and are now more than 12 years old. The process initiated by the European Regulatory authorities to reduce the excess of radiation from CT has however not produced the expected results. Reference diagnostic levels (DRL) from surveys are still twice as high as needed in most European countries and were not significantly reduced as compared to the initial European ones. Many factors may at least explain partially the lack of dose reduction. One of them is the complexity of the dose optimization process while maintaining image quality at a diagnostically acceptable level. Chest is an anatomical region where radiation dose could be substantially reduced because of high natural contrasts between structures, such as air in the lungs and fat in the mediastinum. In this article, the concept of CT radiation dose optimization and the factors that contribute to maintain global excess in radiation dose are reviewed and a brief summary of results from research in the field of chest CT radiation dose is given.

  2. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  3. Dosing of Enoxaparin in Renal Impairment.

    Science.gov (United States)

    Shaikh, Suhail A; Regal, Randolph E

    2017-04-01

    To review enoxaparin treatment dosing, pharmacokinetics, and clinical outcomes data in patients with renal impairment and to examine the current two-tiered dosing regimen approved by the Food and Drug Administration (FDA). A literature search of PubMed (1990-2016) was performed using the search terms low-molecular-weight heparin, unfractionated heparin, bleeding, enoxaparin, renal impairment, pharmacokinetics, and hemodialysis. All studies assessing the pharmacokinetic properties of enoxaparin in patients with renal impairment were evaluated. In addition, all retrospective and prospective studies assessing the safety and efficacy of enoxaparin treatment in this population were evaluated. Five pharmacokinetic studies evaluated changes in the pharmacokinetics of enoxaparin in patients with renal impairment. In these studies, enoxaparin clearance was reduced by 17% to 44% in patients with mild and moderate renal impairment. Six retrospective studies evaluated the safety of enoxaparin in patients with renal impairment. In one study, patients with moderate renal impairment were at increased risk of bleeding when using the current FDA-approved two-tiered scheme (odds ratio, 4.7; 95% confidence interval, 1.7-13.0; P = 0.002). Another study demonstrated that individualized enoxaparin dosing, when compared to FDA-approved dosing, resulted in a decreased risk of bleeding. Two retrospective studies evaluated efficacy. One of these studies compared reduced-dose enoxaparin with unfractionated heparin; there was a trend toward lower incidences of thromboembolism and 30-day mortality with reduced-dose enoxaparin. Hospital length of stay also decreased with reduced-dosed enoxaparin. This paper highlights the differences in the pharmacokinetic properties and safety and efficacy outcomes in multiple degrees of renal impairment when using treatment-dose enoxaparin. Given the literature highlighted in this review, a more multitiered enoxaparin renal dosing strategy-perhaps shifting

  4. Dose assessment in pediatric computerized tomography

    International Nuclear Information System (INIS)

    Vilarinho, Luisa Maria Auredine Lima

    2004-01-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI w obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI w values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI w . (author)

  5. Mammographic dose survey in the Czech Republic

    International Nuclear Information System (INIS)

    Novak, Leos; Rada, Jiri

    2006-01-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  6. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  7. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  8. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  9. Mercury dosing solutions for fluorescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, A; Boffito, C [SAES Getters S.p.A., Viale Italia 77, Lainate (MI) 20020 (Italy)], E-mail: alessio_corazza@saes-group.com

    2008-07-21

    A review of the different technologies used to dose mercury in fluorescent lamps is presented. Conventional liquid mercury dosing is gradually being replaced with more reliable and environmentally friendly solutions that enable a significant reduction of the amount of mercury introduced in the lamp, so as to cope with more stringent regulations issued to minimize the environmental impact of exhausted lamps. This paper will review the most advanced novel methods to assure an accurate and fine dosing of mercury in fluorescent lamps, especially focusing on solutions based on the use of solid alloys.

  10. FUEL HANDLING FACILITY WORKER DOSE ASSESSMENT

    International Nuclear Information System (INIS)

    Achudume, A.

    2004-01-01

    The purpose of this design calculation is to estimate radiation doses received by personnel working in the Fuel Handling Facility (FHF) of the Monitored Geological Repository (MGR). The FHF is a surface facility supporting waste handling operations i.e. receive transportation casks, transfer wastes, prepare waste packages, and ship out loaded waste packages and empty casks. The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation. The results are also limited to normal operations only. Results of this calculation will be used to support the FHF design and License Application

  11. Low doses: myth or true danger

    International Nuclear Information System (INIS)

    Laramee, V.

    1996-01-01

    The question of low doses and the existence of a threshold dose is discussed here. The opinions are shared between scientists of nuclear energy and doctors who think there is a threshold, under it there is no detected effect for health, and the partisans of a zero risk who think that radiations are dangerous at any level. If elementary principles of precaution want that exposure standards continue to decrease, it can be appear for the public as a confirmation of soundness of zero dose thesis, and consequently generate a trust crisis between public and scientists. (N.C.)

  12. User instructions for the CIDER Dose Code

    Energy Technology Data Exchange (ETDEWEB)

    Eslinger, P.W.; Lessor, K.S.; Ouderkirk, S.J.

    1994-05-01

    This document provides user instructions for the CIDER (Calculation of Individual Doses from Environmental Radionuclides) computer code. The CIDER code computes estimates of annual doses estimated for both reference individuals with a known residence and food consumption history. This document also provides user instructions for four utility codes used to build input data libraries for CIDER. These utility codes are ENVFAC (environmental factors), FOOFAC (food factors), LIFFAC (lifestyle factors), and ORGFAC (organ factors). Finally, this document provides user instructions for the EXPAND utility code. The EXPAND code processes a result file from CIDER and extracts a summary of the dose information for reporting or plotting purposes.

  13. Concrete spent fuel storage casks dose rates

    International Nuclear Information System (INIS)

    Bace, M.; Jecmenica, R.; Trontl, K.

    1998-01-01

    Our intention was to model a series of concrete storage casks based on TranStor system storage cask VSC-24, and calculate the dose rates at the surface of the casks as a function of extended burnup and a prolonged cooling time. All of the modeled casks have been filled with the original multi-assembly sealed basket. The thickness of the concrete shield has been varied. A series of dose rate calculations for different burnup and cooling time values have been performed. The results of the calculations show rather conservative original design of the VSC-24 system, considering only the dose rate values, and appropriate design considering heat rejection.(author)

  14. Imaging and concomitant dose in radiotherapy

    International Nuclear Information System (INIS)

    Negi, P.S.

    2008-01-01

    Image guidance in radiotherapy now involves multiple imaging procedures for planning, simulation, set-up inter and intrafraction monitoring. Presently ALARA (i.e. as low as reasonable achievable) is the principle of management of dose to radiation workers and patients in any diagnostic imaging procedures including image guided surgery. The situation is different in repeated radiographic/fluoroscopic imaging performed for simulation, dose planning, patient positioning and set-up corrections during preparation/execution of Image guided radiotherapy (IGRT) as well as for Intensity Modulated Radiotherapy (IMRT). Reported imaging and concomitant doses will be highlighted and discussed for the management and optimization of imaging techniques in IMRT and IGRT

  15. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  16. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  17. Influence of Genotype on Warfarin Maintenance Dose Predictions Produced Using a Bayesian Dose Individualization Tool.

    Science.gov (United States)

    Saffian, Shamin M; Duffull, Stephen B; Roberts, Rebecca L; Tait, Robert C; Black, Leanne; Lund, Kirstin A; Thomson, Alison H; Wright, Daniel F B

    2016-12-01

    A previously established Bayesian dosing tool for warfarin was found to produce biased maintenance dose predictions. In this study, we aimed (1) to determine whether the biased warfarin dose predictions previously observed could be replicated in a new cohort of patients from 2 different clinical settings, (2) to explore the influence of CYP2C9 and VKORC1 genotype on predictive performance of the Bayesian dosing tool, and (3) to determine whether the previous population used to develop the kinetic-pharmacodynamic model underpinning the Bayesian dosing tool was sufficiently different from the test (posterior) population to account for the biased dose predictions. The warfarin maintenance doses for 140 patients were predicted using the dosing tool and compared with the observed maintenance dose. The impact of genotype was assessed by predicting maintenance doses with prior parameter values known to be altered by genetic variability (eg, EC50 for VKORC1 genotype). The prior population was evaluated by fitting the published kinetic-pharmacodynamic model, which underpins the Bayesian tool, to the observed data using NONMEM and comparing the model parameter estimates with published values. The Bayesian tool produced positively biased dose predictions in the new cohort of patients (mean prediction error [95% confidence interval]; 0.32 mg/d [0.14-0.5]). The bias was only observed in patients requiring ≥7 mg/d. The direction and magnitude of the observed bias was not influenced by genotype. The prior model provided a good fit to our data, which suggests that the bias was not caused by different prior and posterior populations. Maintenance doses for patients requiring ≥7 mg/d were overpredicted. The bias was not due to the influence of genotype nor was it related to differences between the prior and posterior populations. There is a need for a more mechanistic model that captures warfarin dose-response relationship at higher warfarin doses.

  18. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  19. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  20. Validation of GPU based TomoTherapy dose calculation engine.

    Science.gov (United States)

    Chen, Quan; Lu, Weiguo; Chen, Yu; Chen, Mingli; Henderson, Douglas; Sterpin, Edmond

    2012-04-01

    The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) GPU dose engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.

  1. Internal dose assessment in radiation accidents

    International Nuclear Information System (INIS)

    Toohey, R.E.

    2003-01-01

    Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose rates to the organs of interest need to be computed from first principles. Standard bioassay methods may be used to assess body contents, but, again, the standard models for bioassay interpretation may not be applicable because of the circumstances of the accident and the prompt initiation of decorporation therapy. Examples of modifications to the standard methodologies include adjustment of biological half-times under therapy, such as in the Goiania accident, and the same effect, complicated by continued input from contaminated wounds, in the Hanford 241 Am accident. (author)

  2. Transforming dose management techniques through technology

    International Nuclear Information System (INIS)

    Bennett, M.

    1996-01-01

    The management of occupational dose exposure has been transformed in recent years through the use of facilities such as computerized databases, remote instrumentation and electronic data transfer. Use of this technology has allowed increases both in the amount of data capable of being processed and in the speed at which the data is made available to operators and Health Physics personnel. These developments have significantly improved the quality and efficiency of dose management. The dose management system being used in support of the UK's naval nuclear plants has incorporated advances in the areas of dosimetry, data handling and data analysis. Physical dispersion of sites servicing the nuclear plants means that effective communication links have also been vital for good dose management. (author)

  3. Dose calculation system for remotely supporting radiotherapy

    International Nuclear Information System (INIS)

    Saito, K.; Kunieda, E.; Narita, Y.; Kimura, H.; Hirai, M.; Deloar, H. M.; Kaneko, K.; Ozaki, M.; Fujisaki, T.; Myojoyama, A.; Saitoh, H.

    2005-01-01

    The dose calculation system IMAGINE is being developed keeping in mind remotely supporting external radiation therapy using photon beams. The system is expected to provide an accurate picture of the dose distribution in a patient body, using a Monte Carlo calculation that employs precise models of the patient body and irradiation head. The dose calculation will be performed utilising super-parallel computing at the dose calculation centre, which is equipped with the ITBL computer, and the calculated results will be transferred through a network. The system is intended to support the quality assurance of current, widely carried out radiotherapy and, further, to promote the prevalence of advanced radiotherapy. Prototypes of the modules constituting the system have already been constructed and used to obtain basic data that are necessary in order to decide on the concrete design of the system. The final system will be completed in 2007. (authors)

  4. Radiation doses and risks from internal emitters

    International Nuclear Information System (INIS)

    Harrison, John; Day, Philip

    2008-01-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  5. Effective dose: a radiation protection quantity

    CERN Document Server

    Menzel, H G

    2012-01-01

    Modern radiation protection is based on the principles of justification, limitation, and optimisation. Assessment of radiation risks for individuals or groups of individuals is, however, not a primary objective of radiological protection. The implementation of the principles of limitation and optimisation requires an appropriate quantification of radiation exposure. The International Commission on Radiological Protection (ICRP) has introduced effective dose as the principal radiological protection quantity to be used for setting and controlling dose limits for stochastic effects in the regulatory context, and for the practical implementation of the optimisation principle. Effective dose is the tissue weighted sum of radiation weighted organ and tissue doses of a reference person from exposure to external irradiations and internal emitters. The specific normalised values of tissue weighting factors are defined by ICRP for individual tissues, and used as an approximate age- and sex-averaged representation of th...

  6. Research and assessment of national population dose

    International Nuclear Information System (INIS)

    Pan Ziqiang

    1984-01-01

    This article describes the necessity and probability of making researches on assessment of national population dose, and discusses some problems which might be noticeable in the research work. (author)

  7. Determination of dose distributions and parameter sensitivity

    International Nuclear Information System (INIS)

    Napier, B.A.; Farris, W.T.; Simpson, J.C.

    1992-12-01

    A series of scoping calculations has been undertaken to evaluate the absolute and relative contribution of different radionuclides and exposure pathways to doses that may have been received by individuals living in the vicinity of the Hanford site. This scoping calculation (Calculation 005) examined the contributions of numerous parameters to the uncertainty distribution of doses calculated for environmental exposures and accumulation in foods. This study builds on the work initiated in the first scoping study of iodine in cow's milk and the third scoping study, which added additional pathways. Addressed in this calculation were the contributions to thyroid dose of infants from (1) air submersion and groundshine external dose, (2) inhalation, (3) ingestion of soil by humans, (4) ingestion of leafy vegetables, (5) ingestion of other vegetables and fruits, (6) ingestion of meat, (7) ingestion of eggs, and (8) ingestion of cows' milk from Feeding Regime 1 as described in Calculation 001

  8. High dose potassium-nitrate chemical dosimeter

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.; Munoz, S.S.

    1982-01-01

    This dosimeter is used to control 10 kGY-order doses (1 Mrad). Nitrate suffers a radiolitic reduction phenomena, which is related to the given dose. The method to use potassium nitrate as dosimeter is described, as well as effects of the temperature of irradiation, pH, nitrate concentration and post-irradiation stability. Nitrate powder was irradiated at a Semi-Industrial Plant, at Centro Atomico Ezeiza, and also in a Gammacell-220 irradiator. The dose rates used were 2,60 and 1,80 KGY/hour, and the given doses varied between 1,0 and 150 KGY. The uncertainty was +-3% in all the range. (author) [es

  9. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  10. Hanford Environmental Dose Reconstruction Project. Monthly report

    Energy Technology Data Exchange (ETDEWEB)

    McMakin, A.H.; Cannon, S.D.; Finch, S.M. [comps.

    1992-07-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source terms, environmental transport, environmental monitoring data, demography, food consumption, and agriculture, and environmental pathways and dose estimates. Progress is discussed.

  11. Hanford Environmental Dose Reconstruction Project monthly report

    Energy Technology Data Exchange (ETDEWEB)

    McMakin, A.H., Cannon, S.D.; Finch, S.M. (comps.)

    1992-09-01

    The objective of the Hanford Environmental Dose Reconstruction MDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in envirorunental pathways. epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering. radiation dosimetry. and cultural anthropology. Included are appointed members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data Demography, Food Consumption, and Agriculture; and Environmental Pathways and Dose Estimates.

  12. Review of surface dose detectors in radiotherapy

    LENUS (Irish Health Repository)

    O'Shea, E.

    2006-11-20

    Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface. Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energy beams for radiation therapy is by means of parallel-plate ionisation chambers. Thermoluminescent dosimeters (TLDs), diodes and radiographic film have also been used to obtain surface dose measurements. The diamond detector was used recently by the author in an investigation on the effects of beam-modifying devices on skin dose and it is also described in this report

  13. Biological Effects of Low-Dose Exposure

    CERN Document Server

    Komochkov, M M

    2000-01-01

    On the basis of the two-protection reaction model an analysis of stochastic radiobiological effects of low-dose exposure of different biological objects has been carried out. The stochastic effects are the results published in the last decade: epidemiological studies of human cancer mortality, the yield of thymocyte apoptosis of mice and different types of chromosomal aberrations. The results of the analysis show that as dependent upon the nature of biological object, spontanous effect, exposure conditions and radiation type one or another form dose - effect relationship is realized: downwards concave, near to linear and upwards concave with the effect of hormesis included. This result testifies to the incomplete conformity of studied effects of 1990 ICRP recomendations based on the linear no-threshold hypothesis about dose - effect relationship. Because of this the methodology of radiation risk estimation recomended by ICRP needs more precisian and such quantity as collective dose ought to be classified into...

  14. Hanford Environmental Dose Reconstruction Project monthly report

    International Nuclear Information System (INIS)

    McMakin, A.H., Cannon, S.D.; Finch, S.M.

    1992-09-01

    The objective of the Hanford Environmental Dose Reconstruction MDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in envirorunental pathways. epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering. radiation dosimetry. and cultural anthropology. Included are appointed members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data Demography, Food Consumption, and Agriculture; and Environmental Pathways and Dose Estimates

  15. The embryogenesis of dose assessment at Hanford

    International Nuclear Information System (INIS)

    Foster, R.F.

    1990-01-01

    Several significant events occurred between 1955 and 1960 that resulted in major changes in environmental monitoring at Hanford and in the initiation of comprehensive dose assessments. These included: (1) specification of dose limits for nonoccupational exposure (including internal emitters); (2) a national and international awakening to the need for managing the disposal of radioactive wastes; (3) identification of the most important radionuclides and their sources of exposure; (4) data that quantified the transfer coefficients of nuclides along environmental pathways; and (5) development of greatly improved radiation detection instrumentation. In response to a growing need, the Hanford Laboratories formed the Environmental Studies and Evaluation component. This group revamped the monitoring and sampling programs so that analytical results contributed directly to dose estimation. Special studies were conducted to ascertain local dietary and recreational habits that affected dose calculations and to calibrate the models. These studies involved extensive contact with the public and governmental agencies, which elicited a positive reaction

  16. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  17. Dose-Response Analysis Using R.

    Directory of Open Access Journals (Sweden)

    Christian Ritz

    Full Text Available Dose-response analysis can be carried out using multi-purpose commercial statistical software, but except for a few special cases the analysis easily becomes cumbersome as relevant, non-standard output requires manual programming. The extension package drc for the statistical environment R provides a flexible and versatile infrastructure for dose-response analyses in general. The present version of the package, reflecting extensions and modifications over the last decade, provides a user-friendly interface to specify the model assumptions about the dose-response relationship and comes with a number of extractors for summarizing fitted models and carrying out inference on derived parameters. The aim of the present paper is to provide an overview of state-of-the-art dose-response analysis, both in terms of general concepts that have evolved and matured over the years and by means of concrete examples.

  18. Calculational Tool for Skin Contamination Dose Assessment

    CERN Document Server

    Hill, R L

    2002-01-01

    Spreadsheet calculational tool was developed to automate the calculations preformed for dose assessment of skin contamination. This document reports on the design and testing of the spreadsheet calculational tool.

  19. Potential radiation doses from 1994 Hanford Operations

    International Nuclear Information System (INIS)

    Soldat, J.K.; Antonio, E.J.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the potential radiation doses to the public from releases originating at the Hanford Site. Members of the public are potentially exposed to low-levels of radiation from these effluents through a variety of pathways. The potential radiation doses to the public were calculated for the hypothetical MEI and for the general public residing within 80 km (50 mi) of the Hanford Site

  20. Dose equivalent rate calculation tool for FBFC

    International Nuclear Information System (INIS)

    Porte, R.; Lengele, C.; Favier, Th.; Duval, A.

    2010-01-01

    The authors present the results obtained by a software designed to compute dose equivalent rate for the critical workstations of the FBFC plant in Romans, France, which will have to deal with an uranium more heavily loaded with U 232 . The uranium spectrum and the ageing time can be varied in order to visualize the evolution of the dose equivalent rate in different locations with respect to the ageing time

  1. Uncertainties on lung doses from inhaled plutonium.

    Science.gov (United States)

    Puncher, Matthew; Birchall, Alan; Bull, Richard K

    2011-10-01

    In a recent epidemiological study, Bayesian uncertainties on lung doses have been calculated to determine lung cancer risk from occupational exposures to plutonium. These calculations used a revised version of the Human Respiratory Tract Model (HRTM) published by the ICRP. In addition to the Bayesian analyses, which give probability distributions of doses, point estimates of doses (single estimates without uncertainty) were also provided for that study using the existing HRTM as it is described in ICRP Publication 66; these are to be used in a preliminary analysis of risk. To infer the differences between the point estimates and Bayesian uncertainty analyses, this paper applies the methodology to former workers of the United Kingdom Atomic Energy Authority (UKAEA), who constituted a subset of the study cohort. The resulting probability distributions of lung doses are compared with the point estimates obtained for each worker. It is shown that mean posterior lung doses are around two- to fourfold higher than point estimates and that uncertainties on doses vary over a wide range, greater than two orders of magnitude for some lung tissues. In addition, we demonstrate that uncertainties on the parameter values, rather than the model structure, are largely responsible for these effects. Of these it appears to be the parameters describing absorption from the lungs to blood that have the greatest impact on estimates of lung doses from urine bioassay. Therefore, accurate determination of the chemical form of inhaled plutonium and the absorption parameter values for these materials is important for obtaining reliable estimates of lung doses and hence risk from occupational exposures to plutonium.

  2. Plastic for indicating a radiation dose

    International Nuclear Information System (INIS)

    Hori, Y.; Yoshikawa, N.; Ohmori, S.

    1975-01-01

    A plastic film suitable for indicating radiation dose contains a chlorine polymer, at least one acid sensitive coloring agent and a plasticizer. The film undergoes a distinct change of color in response to a given radiation dose, the degree of change proportional to the total change. These films may be stored for a long period without loss of sensitivity, and have good color stability after irradiation. (auth)

  3. Dose rate effect in food irradiation

    International Nuclear Information System (INIS)

    Singh, H.

    1991-08-01

    It has been suggested that the minor losses of nutrients associated with radiation processing may be further reduced by irradiating foods at the high dose rates generally associated with electron beams from accelerators, rather than at the low dose rates typical of gamma irradiation (e.g. 60 Co). This review briefly examines available comparative data on gamma and electron irradiation of foods to evaluate these suggestions. (137 refs., 27 tabs., 11 figs.)

  4. Reference Dose Rates for Fluoroscopy Guided Interventions

    International Nuclear Information System (INIS)

    Geleijns, J.; Broerse, J.J.; Hummel, W.A.; Schalij, M.J.; Schultze Kool, L.J.; Teeuwisse, W.; Zoetelief, J.

    1998-01-01

    The wide diversity of fluoroscopy guided interventions which have become available in recent years has improved patient care. They are being performed in increasing numbers, particularly at departments of cardiology and radiology. Some procedures are very complex and require extended fluoroscopy times, i.e. longer than 30 min, and radiation exposure of patient and medical staff is in some cases rather high. The occurrence of radiation-induced skin injuries on patients has shown that radiation protection for fluoroscopy guided interventions should not only be focused on stochastic effects, i.e. tumour induction and hereditary risks, but also on potential deterministic effects. Reference dose levels are introduced by the Council of the European Communities as an instrument to achieve optimisation of radiation protection in radiology. Reference levels in conventional diagnostic radiology are usually expressed as entrance skin dose or dose-area product. It is not possible to define a standard procedure for complex interventions due to the large inter-patient variations with regard to the complexity of specific interventional procedures. Consequently, it is not realistic to establish a reference skin dose or dose-area product for complex fluoroscopy guided interventions. As an alternative, reference values for fluoroscopy guided interventions can be expressed as the entrance dose rates on a homogeneous phantom and on the image intensifier. A protocol has been developed and applied during a nationwide survey of fluoroscopic dose rate during catheter ablations. From this survey reference entrance dose rates of respectively 30 mGy.min -1 on a polymethylmethacrylate (PMMA) phantom with a thickness of 21 cm, and of 0.8 μGy.s -1 on the image intensifier have been derived. (author)

  5. Reducing Radiation Dose in Pediatric Diagnostic Fluoroscopy.

    Science.gov (United States)

    Ghodadra, Anish; Bartoletti, Stefano

    2016-01-01

    To assess radiation dose in common pediatric diagnostic fluoroscopy procedures and determine the efficacy of dose tracking and dose reduction training to reduce radiation use. Fluoroscopy time and radiation dose area product (DAP) were recorded for upper GIs (UGI), voiding cystourethrograms (VCUGs), and barium enemas (BEs) during a six-month period. The results were presented to radiologists followed by a 1-hour training session on radiation dose reduction methods. Data were recorded for an additional six months. DAP was normalized to fluoroscopy time, and Wilcoxon testing was used to assess for differences between groups. Data from 1,479 cases (945 pretraining and 530 post-training) from 9 radiologists were collected. No statistically significant difference was found in patient age, proportion of examination types, or fluoroscopy time between the pre- and post-training groups (P ≥ .1), with the exception of a small decrease in median fluoroscopy time for VCUGs (1.0 vs 0.9 minutes, P = .04). For all examination types, a statistically significant decrease was found in the median normalized DAP (P < .05) between pre- and post-training groups. The median (quartiles) for pretraining and post-training normalized DAPs (μGy·m(2) per minute) were 14.36 (5.00, 38.95) and 6.67 (2.67, 17.09) for UGIs; 13.00 (5.34, 32.71) and 7.16 (2.73, 19.85) for VCUGs; and 33.14 (9.80, 85.26) and 17.55 (7.96, 46.31) for BEs. Radiation dose tracking with feedback, paired with dose reduction training, can reduce radiation dose during diagnostic pediatric fluoroscopic procedures by nearly 50%. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  7. The problem of the population dose

    International Nuclear Information System (INIS)

    Belyaev, V.A.

    1976-08-01

    This report investigates methods of calculating the population dose due to emissions from nuclear reactors. The exposure of the local population is considered as well as the exposure of the population of the remote area where food produced near the reactor site is consumed. Units of measurement for the population dose are discussed. A concrete example is given for calculating the contribution of isotopes of radioactive noble gases, 131 I and 137 Cs. (orig.) [de

  8. Energies, health, medicine. Low radiation doses

    International Nuclear Information System (INIS)

    2004-01-01

    This file concerns the biological radiation effects with a special mention for low radiation doses. The situation of knowledge in this area and the mechanisms of carcinogenesis are detailed, the different directions of researches are given. The radiation doses coming from medical examinations are given and compared with natural radioactivity. It constitutes a state of the situation on ionizing radiations, known effects, levels, natural radioactivity and the case of radon, medicine with diagnosis and radiotherapy. (N.C.)

  9. Offsite doses from SRP radioactive releases - 1985

    International Nuclear Information System (INIS)

    Marter, W.L.

    1986-01-01

    This memorandum summarizes the offsite doses from releases of radioactive materials to the environment from SRP operations in 1985. These doses were calculated for inclusion in the environmental report for 1985 to be issued by the Health Protection Department (DPSPU-86-30-1). The environmental report is prepared annually for distribution to state environmental agencies, the news media, and interested members of the public. More detailed data on offsite exposures by radionuclide and exposure pathway will be included in the environmental report

  10. Some aspects of dose evaluation, 3

    International Nuclear Information System (INIS)

    Yoshida, Yoshikazu

    1979-01-01

    This paper describes methods of calculating the radioiodine releases and resultant doses in the ''Guide for calculation of doses to man from routine releases of effluents from light-water-cooled nuclear power plants for evaluating compliance with dose objectives around a site of LWRs'' by the Japan Nuclear Safety Commission. Examples of dose calculation in the design stage of plants and releases of radioiodine from operating plants are also given. The thyroid dose objective from radioiodine in reactor effluents was determined to be 15 mrem per year by the AEC of Japan in 1975. In the guide, models and parameters are given as most realistic on the basis of current knowledge and experience; in cases involving unknown factors these are on conservative side. Calculations of annual average releases of gaseous and liquid effluents are made using the models and parameters established through operational experiences of the LWR plants. Annual thyroid doses are calculated from inhalation and ingestion of leafy vegetable and cow's milk for gaseous effluents and ingestion of marine food for liquid effluents. In calculation of the thyroid dose, fw = 0.2 is used instead of = 0.3 in ICRP publ. 2 for ingestion of foods excluding seaweed and the specific activity method for ingestion of foods including seaweed. It is because Japanese take foods with much stable iodine. Calculated annual releases of 131 I in gaseous effluents of typical BWR (1100 MWe) and PWR (800 MWe) are about 2 Ci and 0.7 Ci per year per plant and the annual thyroid doses are about 4 mrem and 9 mrem per year, respectively. Actually, however, releases of 131 I in gaseous effluents from the operating LWR plants are about less than one tenth of the above figures. (author)

  11. Managing patient dose in digital radiology

    International Nuclear Information System (INIS)

    2014-01-01

    Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission

  12. Individual radiation doses. Annual report 1995

    International Nuclear Information System (INIS)

    Bergman, L.

    1995-05-01

    During the year we measured whole body doses on 10226 bearers, distributed as follows: 0-0,5 mSv on 8816 persons, 0,6-1,0 mSv on 693 persons, 1,1-5,0 on 678 persons, >5 mSv on 39 persons. At higher dose than 4 mSv/4 weeks, the reason to the irradiation will be investigated. 2 figs, 2 tabs

  13. The health detriment associated with low doses of ionising radiation

    International Nuclear Information System (INIS)

    Smith, H.

    1991-01-01

    Some of the problems and uncertainties in using available data to derive risk estimates are discussed in relation to low dose irradiation. Topics considered are:- dose and dose response relationships for stochastic effects following low doses of low LET radiation, estimates of probability of human radiation-induced cancer at low doses, proposed estimates of probability of fatal cancer for low dose, low dose rate, low-LET radiation, natural incidence of severe hereditary diseases, estimates of probability of radiation-induced severe hereditary diseases at low doses, deterministic effects resulting from low dose prenatal exposure, cancer induction including leukemia following human in utero irradiation, mental retardation, and total health detriment. (UK)

  14. Vancomycin Dosing in Obese Patients: Special Considerations and Novel Dosing Strategies.

    Science.gov (United States)

    Durand, Cheryl; Bylo, Mary; Howard, Brian; Belliveau, Paul

    2017-12-01

    To review the literature regarding vancomycin pharmacokinetics in obese patients and strategies used to improve dosing in this population. PubMed, EMBASE (1974 to November 2017), and Google Scholar searches were conducted using the search terms vancomycin, obese, obesity, pharmacokinetics, strategy, and dosing. Additional articles were selected from reference lists of selected studies. Included articles were those published in English with a primary focus on vancomycin pharmacokinetic parameters in obese patients and practical vancomycin dosing strategies, clinical experiences, or challenges of dosing vancomycin in this population. Volume of distribution and clearance are the pharmacokinetic parameters that most often affect vancomycin dosing in obese patients; both are increased in this population. Challenges with dosing in obese patients include inconsistent and inadequate dosing, observations that the obese population may not be homogeneous, and reports of an increased likelihood of supratherapeutic trough concentrations. Investigators have revised and developed dosing and monitoring protocols to address these challenges. These approaches improved target trough attainment to varying degrees. Some of the vancomycin dosing approaches provided promising results in obese patients, but there were notable differences in methods used to develop these approaches, and sample sizes were small. Although some approaches can be considered for validation in individual institutions, further research is warranted. This may include validating approaches in larger populations with narrower obesity severity ranges, investigating target attainment in indication-specific target ranges, and evaluating the impact of different dosing weights and methods of creatinine clearance calculation.

  15. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  16. Factors affecting patient dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Poletti, J.L.

    1994-03-01

    The report, Factors Affecting Patient Dose in Diagnostic Radiology is divided into three main sections. Part one is introductory and covers the basic principles of x-ray production and image formation. It includes discussion of x-ray generators and x-ray tubes, radiation properties and units, specification and measurement of x-ray beams, methods of patient dose measurement, radiation effects, radiation protection philosophy and finally the essentials of imaging systems. Part two examines factors affecting the x-ray output of x-ray machines and the characteristics of x-ray beams. These include the influence of heat ratings, kVp, waveform, exposure timer, filtration, focus-film distance, beam intensity distribution, x-ray tube age and focal spot size. Part three examines x-ray machine, equipment and patient factors which affect the dose received by individual patients. The factors considered include justification of examinations, choice of examination method, film/screen combinations, kVp, mAs, focus-film distance, collimation and field size, exposure time, projection, scatter, generator calibration errors, waveform, filtration, film processing and patient size. The patient dose implications of fluoroscopy systems, CT scanners, special procedures and mammography are also discussed. The report concludes with a brief discussion of patient dose levels in New Zealand and dose optimisation. 104 refs., 32 figs., 27 tabs

  17. The Hanford Environmental Dose Reconstruction Project: Overview

    International Nuclear Information System (INIS)

    Haerer, H.A.; Freshley, M.D.; Gilbert, R.O.; Morgan, L.G.; Napier, B.A.; Rhoads, R.E.; Woodruff, R.K.

    1990-01-01

    In 1988, researchers began a multiyear effort to estimate radiation doses that people could have received since 1944 at the U.S. Department of Energy's Hanford Site. The study was prompted by increasing concern about potential health effects to the public from more than 40 yr of nuclear activities. We will provide an overview of the Hanford Environmental Dose Reconstruction Project and its technical approach. The work has required development of new methods and tools for dealing with unique technical and communication challenges. Scientists are using a probabilistic, rather than the more typical deterministic, approach to generate dose distributions rather than single-point estimates. Uncertainties in input parameters are reflected in dose results. Sensitivity analyses are used to optimize project resources and define the project's scope. An independent technical steering panel directs and approves the work in a public forum. Dose estimates are based on review and analysis of historical data related to operations, effluents, and monitoring; determination of important radionuclides; and reconstruction of source terms, environmental conditions that affected transport, concentrations in environmental media, and human elements, such as population distribution, agricultural practices, food consumption patterns, and lifestyles. A companion paper in this volume, The Hanford Environmental Dose Reconstruction Project: Technical Approach, describes the computational framework for the work

  18. Radiation doses from radioactivity in incandescent mantles

    International Nuclear Information System (INIS)

    1985-01-01

    Thorium nitrate is used in the production of incandescent mantles for gas lanterns. In this report dose estimates are given for internal and external exposure that result from the use of the incandescent mantles for gas lanterns. The collective, effective dose equivalent for all users of gas mantles is estimated to be about 100 Sv per annum in the Netherlands. For the population involved (ca. 700,000 persons) this is roughly equivalent to 5% to 10% of the collective dose equivalent associated with exposure to radiation from natural sources. The major contribution to dose estimates comes from inhalation of radium during burning of the mantles. A pessimistic approach results in individual dose estimates for inhalation of up to 0.2 mSv. Consideration of dose consequences in case of a fire in a storage department learns that it is necessary for emergency personnel to wear respirators. It is concluded that the uncontrolled removal of used gas mantles to the environment (soil) does not result in a significant contribution to environmental radiation exposure. (Auth.)

  19. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B; Kovacevic, S.; Ranogajec-Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    The diagnostic value of computerized tomography has increased due to very rapid technical advances in both equipment and techniques. When the CT scanners were introduced, a significant problem for the specification of the radiation dose imparted to the patient undergoing CT examination has been created. In CT, the conditions of exposure are quite different from those in conventional X-ray imaging. CT procedure involves the continuous tomography of thin layers. Some of these layers touch each other while others overlap. The radiation doses received by patients can vary considerably. In addition to the radiation from the collimated primary beam, patients are exposed to significant scattered doses in unpredictable amounts. Every effort should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The aims of this work were to determine the surface doses delivered to various organs of patients during various computerized tomography examinations (head, thorax, kidney, abdomen and pelvis). Particular attention was directed to the precise determination of doses received by the eyes (during CT of head) and gonads (during CT of pelvis and lower abdomen) since these organs can be near or even in the primary X-ray beam

  20. Bremsstrahlung doses from natural uranium ingots

    International Nuclear Information System (INIS)

    Anderson, J. L.; Hertel, N. E.

    2005-01-01

    In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and Bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and Bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from ∼51-84 μSv h -1 and 17-95 μSv h -1 using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and Bremsstrahlung were the same order of magnitude for each object. (authors)

  1. Bremsstrahlung doses from natural uranium ingots.

    Science.gov (United States)

    Anderson, Jeri L; Hertel, Nolan E

    2005-01-01

    In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from approximately 51-84 microSv h(-1) and 17-95 microSv h(-1) using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and bremsstrahlung were the same order of magnitude for each object.

  2. Carcinogenesis induced by low-dose radiation

    Directory of Open Access Journals (Sweden)

    Piotrowski Igor

    2017-11-01

    Full Text Available Although the effects of high dose radiation on human cells and tissues are relatively well defined, there is no consensus regarding the effects of low and very low radiation doses on the organism. Ionizing radiation has been shown to induce gene mutations and chromosome aberrations which are known to be involved in the process of carcinogenesis. The induction of secondary cancers is a challenging long-term side effect in oncologic patients treated with radiation. Medical sources of radiation like intensity modulated radiotherapy used in cancer treatment and computed tomography used in diagnostics, deliver very low doses of radiation to large volumes of healthy tissue, which might contribute to increased cancer rates in long surviving patients and in the general population. Research shows that because of the phenomena characteristic for low dose radiation the risk of cancer induction from exposure of healthy tissues to low dose radiation can be greater than the risk calculated from linear no-threshold model. Epidemiological data collected from radiation workers and atomic bomb survivors confirms that exposure to low dose radiation can contribute to increased cancer risk and also that the risk might correlate with the age at exposure.

  3. Population dose near the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Hille, R.; Hill, P.; Kluson, J.; Seisebaev, A.; Smagulov, S.

    1998-01-01

    To determine the consequences of atmospheric atomic bomb tests for the population in the surroundings of the former nuclear weapons test site near Semipalatinsk in Kazakhstan, a pilot study was performed by an international cooperation between Kazakh, French, Czech and German institutions at two villages, Mostik and Maisk. Together with Kazakh scientists, eight experts from Europe carried out a field mission in September 1995 to assess, within the framework of a NATO supported project, the radiological situation as far as external doses, environmental contamination and body burden of man were concerned. A summary of the results obtained is presented. The actual radiological situation near the test site is characterized by fallout contaminations. Cs was found in upper soil layers in concentrations similar to those of the global fallout. Also Sr, Am and Co were observed. The resulting present dose to the population is low. Mean external doses from soil contamination for Maisk and Mostik (0.60-0.63 mSv/ year) presently correspond to mean external doses in normal environments. Mean values of the annual internal doses observed in these two villages are below 2 μSv/year for 90 Sr. For other radionuclides the internal doses are also negligible. (orig.)

  4. Dose escalation of a curcuminoid formulation

    Directory of Open Access Journals (Sweden)

    Crowell James

    2006-03-01

    Full Text Available Abstract Background Curcumin is the major yellow pigment extracted from turmeric, a commonly-used spice in India and Southeast Asia that has broad anticarcinogenic and cancer chemopreventive potential. However, few systematic studies of curcumin's pharmacology and toxicology in humans have been performed. Methods A dose escalation study was conducted to determine the maximum tolerated dose and safety of a single dose of standardized powder extract, uniformly milled curcumin (C3 Complex™, Sabinsa Corporation. Healthy volunteers were administered escalating doses from 500 to 12,000 mg. Results Seven of twenty-four subjects (30% experienced only minimal toxicity that did not appear to be dose-related. No curcumin was detected in the serum of subjects administered 500, 1,000, 2,000, 4,000, 6,000 or 8,000 mg. Low levels of curcumin were detected in two subjects administered 10,000 or 12,000 mg. Conclusion The tolerance of curcumin in high single oral doses appears to be excellent. Given that achieving systemic bioavailability of curcumin or its metabolites may not be essential for colorectal cancer chemoprevention, these findings warrant further investigation for its utility as a long-term chemopreventive agent.

  5. Radiation Leukemogenesis at Low Dose Rates

    Energy Technology Data Exchange (ETDEWEB)

    Weil, Michael; Ullrich, Robert

    2013-09-25

    The major goals of this program were to study the efficacy of low dose rate radiation exposures for the induction of acute myeloid leukemia (AML) and to characterize the leukemias that are caused by radiation exposures at low dose rate. An irradiator facility was designed and constructed that allows large numbers of mice to be irradiated at low dose rates for protracted periods (up to their life span). To the best of our knowledge this facility is unique in the US and it was subsequently used to study radioprotectors being developed for radiological defense (PLoS One. 7(3), e33044, 2012) and is currently being used to study the role of genetic background in susceptibility to radiation-induced lung cancer. One result of the irradiation was expected; low dose rate exposures are ineffective in inducing AML. However, another result was completely unexpected; the irradiated mice had a very high incidence of hepatocellular carcinoma (HCC), approximately 50%. It was unexpected because acute exposures are ineffective in increasing HCC incidence above background. This is a potential important finding for setting exposure limits because it supports the concept of an 'inverse dose rate effect' for some tumor types. That is, for the development of some tumor types low dose rate exposures carry greater risks than acute exposures.

  6. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  7. Effect of nitrogen doses on disease severity and watermelon yield Influência de doses de nitrogênio na severidade de doenças e na produtividade da melancia

    Directory of Open Access Journals (Sweden)

    Gil R dos Santos

    2009-09-01

    Full Text Available Nitrogen fertilization is an important step for watermelon (Citrullus lanatus production due to its influence over yield, fruit quality, and disease severity. Currently, the gummy stem blight (Didymella bryoniae and the downy mildew (Pseudoperonospora cubensis can be taken as the most important watermelon diseases, since they impose severe impairment to the crop. Furthermore, studies focusing on plant responses to nitrogen fertilization regarding fruit yield and quality, and disease resistance are rare. Hence, the present study aimed at evaluating the effect of nitrogen doses on fruit yield and quality, and on disease prevalence in watermelon. Two experiments were carried out at the Universidade Federal de Tocantins, employing sprinkler irrigation, in an area previously used to grow watermelon. The experimental design was blocks at random, with five treatments (N doses, applied twice as side-dressing, in kg ha-1, as follows: T1= control treatment without N, T2= 20, T3= 40, T4= 80, and T5= 120, and four replications. Urea (45% N was used as the N source. In the first assay, the highest fruit yield and average weight were observed when 40 kg ha-1 of N were applied. The highest severity of the gummy stem blight was observed when the highest nitrogen doses were applied (80 and 120 kg ha-1. In the second assay, the highest severity levels of the gummy stem blight, as well as of mildew, were observed again when N doses were the highest (80 and 120 kg ha-1. The lowest severity levels for both diseases were observed in the control treatment.A adubação nitrogenada é importante para a cultura da melancia (Citrullus lanatus por afetar diretamente a produtividade, a qualidade dos frutos e a severidade de doenças. Atualmente, o crestamento gomoso (Didymella bryoniae e o míldio (Pseudoperonospora cubensis podem ser consideradas as doenças mais importantes da melancia devido aos prejuízos que podem causar na lavoura. Estudos envolvendo a aplicação de

  8. Three-Dimensional Electron Beam Dose Calculations.

    Science.gov (United States)

    Shiu, Almon Sowchee

    The MDAH pencil-beam algorithm developed by Hogstrom et al (1981) has been widely used in clinics for electron beam dose calculations for radiotherapy treatment planning. The primary objective of this research was to address several deficiencies of that algorithm and to develop an enhanced version. Two enhancements have been incorporated into the pencil-beam algorithm; one models fluence rather than planar fluence, and the other models the bremsstrahlung dose using measured beam data. Comparisons of the resulting calculated dose distributions with measured dose distributions for several test phantoms have been made. From these results it is concluded (1) that the fluence-based algorithm is more accurate to use for the dose calculation in an inhomogeneous slab phantom, and (2) the fluence-based calculation provides only a limited improvement to the accuracy the calculated dose in the region just downstream of the lateral edge of an inhomogeneity. The source of the latter inaccuracy is believed primarily due to assumptions made in the pencil beam's modeling of the complex phantom or patient geometry. A pencil-beam redefinition model was developed for the calculation of electron beam dose distributions in three dimensions. The primary aim of this redefinition model was to solve the dosimetry problem presented by deep inhomogeneities, which was the major deficiency of the enhanced version of the MDAH pencil-beam algorithm. The pencil-beam redefinition model is based on the theory of electron transport by redefining the pencil beams at each layer of the medium. The unique approach of this model is that all the physical parameters of a given pencil beam are characterized for multiple energy bins. Comparisons of the calculated dose distributions with measured dose distributions for a homogeneous water phantom and for phantoms with deep inhomogeneities have been made. From these results it is concluded that the redefinition algorithm is superior to the conventional

  9. dose in cervical cancer intracavitary brachytherapy

    Directory of Open Access Journals (Sweden)

    Zahra Siavashpour

    2016-04-01

    Full Text Available Purpose: To analyze the optimum organ filling point for organs at risk (OARs dose in cervical cancer high-dose-rate (HDR brachytherapy. Material and methods : In a retrospective study, 32 locally advanced cervical cancer patients (97 insertions who were treated with 3D conformal external beam radiation therapy (EBRT and concurrent chemotherapy during 2010-2013 were included. Rotterdam HDR tandem-ovoid applicators were used and computed tomography (CT scanning was performed after each insertion. The OARs delineation and GEC-ESTRO-based clinical target volumes (CTVs contouring was followed by 3D forward planning. Then, dose volume histogram (DVH parameters of organs were recorded and patients were classified based on their OARs volumes, as well as their inserted tandem length. Results : The absorbed dose to point A ranged between 6.5-7.5 Gy. D 0.1cm ³ and D 2cm ³ of the bladder significantly increased with the bladder volume enlargement (p value < 0.05. By increasing the bladder volume up to about 140 cm3, the rectum dose was also increased. For the cases with bladder volumes higher than 140 cm3, the rectum dose decreased. For bladder volumes lower than 75 cm3, the sigmoid dose decreased; however, for bladder volumes higher than 75 cm3, the sigmoid dose increased. The D 2cm ³ of the bladder and rectum were higher for longer tandems than for shorter ones, respectively. The divergence of the obtained results for different tandem lengths became wider by the extension of the bladder volume. The rectum and sigmoid volume had a direct impact on increasing their D 0.1cm ³ and D 2cm ³, as well as decreasing their D 10 , D 30 , and D 50 . Conclusions : There is a relationship between the volumes of OARs and their received doses. Selecting a bladder with a volume of about 70 cm3 or less proved to be better with regards to the dose to the bladder, rectum, and sigmoid.

  10. Dose mapping in category I irradiators

    International Nuclear Information System (INIS)

    Mondal, Sandip; Shinde, S.H.; Mhatre, S.G.V.

    2012-01-01

    Category I irradiators such as Gamma Chambers and Blood Irradiators are compact self shielded, dry source storage gamma irradiators offering irradiation volume of few hundred cubic centimeters. In the present work, dose distribution profiles along the central vertical plane of the irradiation volume of Gamma Chamber 900 and Blood Irradiator 2000 were measured using Fricke, FBX, and alanine dosimeters. Measured dose distribution profiles in Gamma Chamber 900 differed from the typical generic dose distribution pattern whereas that in Blood Irradiator 2000 was in agreement with the typical pattern. All reagents used were of analytical reagent grade and were used without further purification. Preparation and dose estimations of Fricke and FBX were carried out as recommended. Alanine pellets were directly placed in precleaned polystyrene container having dimensions 6.5 mm o.d., 32 mm height and 3 mm wall thickness. For these dosimeters, dose measurements were made using e-scan Bruker BioSpin alanine dedicated ESR spectrometer. Specially designed perspex jigs were used during irradiation in Gamma Chamber 900 and Blood Irradiator 2000. These jigs provided the reproducible geometry during irradiation, Absorbance measurements were made using a spectrophotometer calibrated as per the recommended procedure. In Gamma Chamber 900, there is a dose distribution variation of about 34% from top to the center, 18% from center to the bottom, and 15% from center to the periphery. Such a dose distribution profile is largely deviating from the typical profile wherein 15% variation is observed from center to the periphery on all sides. Further investigation showed that there was a nonalignment in the source and sample chamber. However, in Blood Irradiator 2000, there is a dose distribution variation of about 20% from top to the center, 15% from center to the bottom, and 12% from center to the periphery. This pattern is very much similar to the typical profile. Hence it is recommended

  11. Elucidating the role of dose in the biopharmaceutics classification of drugs: the concepts of critical dose, effective in vivo solubility, and dose-dependent BCS.

    Science.gov (United States)

    Charkoftaki, Georgia; Dokoumetzidis, Aristides; Valsami, Georgia; Macheras, Panos

    2012-11-01

    To develop a dose dependent version of BCS and identify a critical dose after which the amount absorbed is independent from the dose. We utilized a mathematical model of drug absorption in order to produce simulations of the fraction of dose absorbed (F) and the amount absorbed as function of the dose for the various classes of BCS and the marginal cases in between classes. Simulations based on the mathematical model of F versus dose produced patterns of a constant F throughout a wide range of doses for drugs of Classes I, II and III, justifying biowaiver claim. For Classes I and III the pattern of a constant F stops at a critical dose Dose(cr) after which the amount of drug absorbed, is independent from the dose. For doses higher than Dose(cr), Class I drugs become Class II and Class III drugs become Class IV. Dose(cr) was used to define an in vivo effective solubility as S(eff) = Dose(cr)/250 ml. Literature data were used to support our simulation results. A new biopharmaceutic classification of drugs is proposed, based on F, separating drugs into three regions, taking into account the dose, and Dose(cr), while the regions for claiming biowaiver are clearly defined.

  12. Creation and clinical application of real-time dose monitor using dose area product meter

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Uoyama, Yoshinori; Iida, Hiroji; Mizushima, Takashi

    2004-01-01

    The management of patient dose has become more of an issue in recent years. Dose can be determined non-invasively and in real time through the use of a dose area product meter, but it is the area dose value that is obtained. Therefore, we created a program that estimates entrance skin dose (ESD) in real time from area dose values obtained during procedures. We used Microsoft Visual C++ 6.0 (Standard Edition) for the programming language and C language for the programming environment. The value was a maximum 285.4 mGy at ileus tube insertion when measuring ESD for radiography of the digestive organ and non-vascular type interventional radiology (IVR) using the created program and seeking the average according to the procedures. The program that we created can be considered valid for monitoring ESD correctly and in real time. (author)

  13. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  14. Occupational Doses and the Contribution to the Population Dose in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Jae; Kyu, Hwan Jeong [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  15. Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT.

    Science.gov (United States)

    Mascalchi, M; Mazzoni, L N; Falchini, M; Belli, G; Picozzi, G; Merlini, V; Vella, A; Diciotti, S; Falaschi, F; Lopes Pegna, A; Paci, E

    2012-08-01

    Few data are available on the effective dose received by participants in lung cancer screening programmes with low-dose CT (LDCT). We report the collective effective dose delivered to 1406 current or former smokers enrolled in the ITALUNG trial who completed 4 annual LDCT examinations and related further investigations including follow-up LDCT, 2-[(18)F]flu-2-deoxy-d-glucose positron emission tomography (FDG-PET) or CT-guided fine needle aspiration biopsy (FNAB). Using the air CT dose index and Monte Carlo simulations on an anthropomorphic phantom, the whole-body effective dose associated with LDCT was determined for the eight CT scanners used in the trial. A value of 7 mSv was assigned to FDG-PET while the measured mean effective dose of CT-guided FNAB was 1.5 mSv. The mean collective effective dose in the 1406 subjects ranged between 8.75 and 9.36 Sv and the mean effective dose to the single subject over 4 years was between 6.2 and 6.8 mSv (range 1.7-21.5 mSv) according to the cranial-caudal length of the LDCT volume. 77.4% of the dose was owing to annual LDCT and 22.6% to further investigations. Considering the nominal risk coefficients for stochastic effects after exposure to low-dose radiation according to the National Radiological Protection Board, International Commission on Radiological Protection (ICRP) 60, ICRP103 and Biological Effects of Ionizing Radiation VII, the mean number of radiation-induced cancers ranged between 0.12 and 0.33 per 1000 subjects. The individual effective dose to participants in a 4-year lung cancer screening programme with annual LDCT is very low and about one-third of the effective dose that is associated with natural background radiation and diagnostic radiology in the same time period.

  16. Biological effects of low doses of radiation at low dose rate

    International Nuclear Information System (INIS)

    1996-05-01

    The purpose of this report was to examine available scientific data and models relevant to the hypothesis that induction of genetic changes and cancers by low doses of ionizing radiation at low dose rate is a stochastic process with no threshold or apparent threshold. Assessment of the effects of higher doses of radiation is based on a wealth of data from both humans and other organisms. 234 refs., 26 figs., 14 tabs

  17. Evaluation of the sterility of single-dose medications used in a multiple-dose fashion.

    Science.gov (United States)

    Martin, Elizabeth P; Mukherjee, Jean; Sharp, Claire R; Sinnott-Stutzman, Virginia B

    2017-11-01

    Bacterial proliferation was evaluated in single-dose medications used in a multi-dose fashion and when medications were intentionally inoculated with bacteria. Of 5 experimentally punctured medications, 1 of 75 vials (50% dextrose) became contaminated. When intentionally inoculated, hydroxyethyl starch and heparinized saline supported microbial growth. Based on these findings, it is recommended that hydroxyethyl starch and heparinized saline not be used in a multi-dose fashion.

  18. Occupational Doses and the Contribution to the Population Dose in Korea

    International Nuclear Information System (INIS)

    Han, Seung Jae; Kyu, Hwan Jeong

    2016-01-01

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  19. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  20. Absorbed Doses to Patients in Nuclear Medicine

    International Nuclear Information System (INIS)

    Leide-Svegborn, Sigrid; Mattsson, Soeren; Nosslin, Bertil; Johansson, Lennart

    2004-09-01

    The work with a Swedish catalogue of radiation absorbed doses to patients undergoing nuclear medicine investigations has continued. After the previous report in 1999, biokinetic data and dose estimates (mean absorbed dose to various organs and tissues and effective dose) have been produced for a number of substances: 11 C- acetate, 11 C- methionine, 18 F-DOPA, whole antibody labelled with either 99m Tc, 111 In, 123 I or 131 I, fragment of antibody, F(ab') 2 labelled with either 99m Tc, 111 In, 123 I or 131 I and fragment of antibody, Fab' labelled with either 99m Tc, 111 In, 123 I or 131 I. The absorbed dose estimates for these substances have been made from published biokinetic information. For other substances of interest, e.g. 14 C-urea (children age 3-6 years), 14 C-glycocholic acid, 14 C-xylose and 14 C-triolein, sufficient literature data have not been available. Therefore, a large number of measurements on patients and volunteers have been carried out, in order to determine the biokinetics and dosimetry for these substances. Samples of breast milk from 50 mothers, who had been subject to nuclear medicine investigations, have been collected at various times after administration of the radiopharmaceutical to the mother. The activity concentration in the breast milk samples has been measured. The absorbed dose to various organs and tissues and the effective dose to the child who ingests the milk have been determined for 17 different radiopharmaceuticals. Based on these results revised recommendations for interruption of breast-feeding after nuclear medicine investigations are suggested

  1. Bioavailability of diclofenac potassium at low doses

    Science.gov (United States)

    Hinz, Burkhard; Chevts, Julia; Renner, Bertold; Wuttke, Henrike; Rau, Thomas; Schmidt, Andreas; Szelenyi, Istvan; Brune, Kay; Werner, Ulrike

    2005-01-01

    Aim Diclofenac-K has been recently launched at low oral doses in different countries for over-the-counter use. However, given the considerable first-pass metabolism of diclofenac, the degree of absorption of diclofenac-K at low doses remained to be determined. The aim of this study was to determine the bioavailability of low-dose diclofenac-K. Methods A randomized, three-way, cross-over study was performed in 10 subjects. Each received diclofenac-K, 22.5 mg via short-term i.v. infusion and orally at single doses of 12.5 mg and 25 mg. Results Mean (± SD) times to maximal plasma concentration (tmax) of diclofenac were 0.48 ± 0.28 h (12.5 mg) and 0.93 ± 0.96 h (25 mg). The absolute bioavailability of diclofenac-K after oral administration did not differ significantly in the 12.5-mg and 25-mg dose group (63.1 ± 12.6% vs. 65.1 ± 19.4%, respectively). The 90% confidence intervals for the AUC∞ and AUCt ratios for the two oral regimes were 82.6, 103.4% (point estimate 92.4%) and 86.2, 112.9% (point estimate 98.6%), respectively. These values were within the acceptance criteria for bioequivalence (80–125%). Conclusions Our data indicate that diclofenac-K is rapidly and well absorbed at low dose, and are consistent with a rapid onset of action of the drug. Abbreviations AUC, area under plasma concentraton-time curve; Cmax, peak plasma concentration; CI, confidence interval; COX, cyclooxygenase; D, dose; F, absolute bioavailability; tmax, time to reach Cmax. PMID:15606444

  2. Analysis of T101 outage radiation dose

    International Nuclear Information System (INIS)

    Li, Zhonghua

    2008-01-01

    Full text: Collective radiation dose during outage is about 80% of annual collective radiation dose at nuclear power plants (NPPs). T 101 Outage is the first four-year outage of Unit 1 at Tianwan Nuclear Power Station (TNPS) and thorough overhaul was undergone for the 105-day's duration. Therefore, T 101 Outage has significant reference meaning to reducing collective radiation dose at TNPS. This paper collects the radiation dose statistics during T 101 Outage and analyses the radiation dose distribution according to tasks, work kinds and varying trend of the collective radiation dose etc., comparing with other similar PWRs in the world. Based on the analysis this paper attempts to find out the major factors in collective radiation dose during T 101 Outage. The major positive factor is low radiation level at workplace, which profits from low content of Co in reactor construction materials, optimised high-temperature p H value of the primary circuit coolant within the tight range and reactor operation without trips within the first fuel cycle. One of the most negative factors is long outage duration and many person-hours spent in the radiological controlled zone, caused by too many tasks and inefficient work. So besides keeping good performance of reducing radioactive sources, it should be focused on how to improve implementation of work management including work selection, planning and scheduling, work preparation, work implementation, work assessment and feedback, which can lead to reduced numbers of workers needed to perform a task, of person-hours spent in the radiological controlled zone. Moreover, this leads to reduce occupational exposures in an ALARA fashion. (author)

  3. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  4. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  5. Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT

    OpenAIRE

    Mascalchi, M; Mazzoni, L N; Falchini, M; Belli, G; Picozzi, G; Merlini, V; Vella, A; Diciotti, S; Falaschi, F; Lopes Pegna, A; Paci, E

    2012-01-01

    Few data are available on the effective dose received by participants in lung cancer screening programmes with low-dose CT (LDCT). We report the collective effective dose delivered to 1406 current or former smokers enrolled in the ITALUNG trial who completed 4 annual LDCT examinations and related further investigations including follow-up LDCT, 2-[18F]flu-2-deoxy-d-glucose positron emission tomography (FDG-PET) or CT-guided fine needle aspiration biopsy (FNAB). Using the air CT dose index and...

  6. Committed equivalent organ doses and committed effective doses from intakes of radionuclides

    CERN Document Server

    Phipps, A W; Kendall, G M; Silk, T J; Stather, J W

    1991-01-01

    This report contains details of committed equivalent doses to individual organs for intakes by ingestion and inhalation of 1 mu m AMAD particles of 359 nuclides by infants aged 3 months, by children aged 1, 5, 10 and 15 years, and by adults. It complements NRPB-R245 which describes the changes which have taken place since the last NRPB compendium of dose per unit intake factors (dose coefficients) and gives summary tables. Information on the way committed doses increase with the integration period is given in NRPB-M289. The information given in these memoranda is also available as a microcomputer package - NRPB-SR245.

  7. Dose Reduction and Dose Management in Computed Tomography - State of the Art.

    Science.gov (United States)

    Zinsser, Dominik; Marcus, Roy; Othman, Ahmed E; Bamberg, Fabian; Nikolaou, Konstantin; Flohr, Thomas; Notohamiprodjo, Mike

    2018-03-13

     For years, the number of performed CT examinations has been rising. At the same time, computed tomography became more dose efficient. The aim of this article is to give an overview about the state of the art in dose reduction in CT and to highlight currently available tools in dose management.  By performing a literature research on Pubmed regarding dose reduction in CT, relevant articles were identified and analyzed.  Technical innovations with individual adaptation of tube current and voltage as well as iterative image reconstruction enable a considerable dose reduction with preserved image quality. At the same time, dedicated software tools are able to handle huge amounts of data and allow to optimize existing examination protocols.   · CT examinations are increasingly performed and contribute considerably to non-natural radiation exposure.. · A correct indication is crucial for each CT examination.. · The examination protocol has to be tailored to the medical question and patient.. · Multiple technical innovations enable considerable dose reduction with constant image quality.. · Dose management with dedicated software tools gains importance.. · Zinsser D, Marcus R, Othman AE et al. Dose reduction and dose management in computed tomography - State of the art. Fortschr Röntgenstr 2018; DOI: 10.1055/s-0044-101261. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Evaluation of effective doses and population doses for computed tomography exposure in Taiwan

    International Nuclear Information System (INIS)

    Yeh, S.H.; Hsu, W.J.; Hsiao, H.S.

    2000-01-01

    As estimated, more than 80% of the man-made radiation dose is derived from medical applications, particularly from diagnostic treatment. Therefore, evaluating the radiation dose from diagnostic treatments is very important. The purpose of this study is to investigate the organ dose distribution and the effective doses from brain, chest and abdomen CT examinations. The organ equivalent dose and effective dose of patients were evaluated by exposing a male RANDO phantom to CT X-ray. Dose distributions in various organs were investigated using TLD LiF:Mg,Ti powder. A total of 224 TLDs were embedded in various organs of the phantom for each CT exposure. The organs that were monitored included bladder, bone marrow, breast, colon, liver, long, oesophagus, skin, stomach, thyroid and tests. The effective doses were calculated with reference to the tissue weighting factors recommended by the ICRP 60 report. Experimental TLDs were carefully calibrated using a secondary standard ionization chamber and a special X-ray machine, before they were exposed at hospitals. Taiwanese hospitals are classified as medical centers, area hospitals and local hospitals. This study investigated one hospital in each category. The experiments were performed according to the parameters (kVp, mAs) and procedures used in actual clinical examinations. In addition, this investigation also adopted the statistical mean and median parameters that obtained by a nationwide questionnaire methods in 1993 for it's CT X-ray exposure experiments. The organ doses significantly affected by the exposed region, i.e., brain, chest or abdomen. The effective doses were in the range of 0.93 to 2.41 mSv, 2.96 to 14.53 mSv and 4.55 to 12.30 mSv for brain, chest and abdomen exposure respectively. The investigated hospitals showed wide range of effective dose to the patients by the reasons of different CT machine, different exposure parameters (kVp, mAs) and different treatment procedures. This is the first time to

  9. The absorbed dose and the effective dose of panoramic temporo mandibular joint radiography

    International Nuclear Information System (INIS)

    Matsuo, Ayae; Gotoh, Kenichi; Yokoi, Midori; Hirukawa, Akiko; Okumura, Shinji; Okano, Tsuneichi; Koyama, Syuji

    2011-01-01

    This study measured the radiation doses absorbed by the patient during Panoramic temporo mandibular joint radiography (Panoramic TMJ), Schullers method and Orbitoramus projection. The dose of the frontal view in Panoramic TMJ was compared to that with Orbitoramus projection and the lateral view in Panoramic TMJ was compared to that with Schuellers method. We measured the doses received by various organs and calculated the effective doses using the guidelines of the International Commission on Radiological Protection in Publication 103. Organ absorbed doses were measured using an anthropomorphic phantom, loaded with thermoluminescent dosimeters (TLD), located at 160 sensitive sites. The dose shows the sum value of irradiation on both the right and left sides. In addition, we set a few different exposure field sizes. The effective dose for a frontal view in Panoramic TMJ was 11 μSv, and that for the lateral view was 14 μSv. The lens of the Orbitoramus projection was 40 times higher than the frontal view in Panoramic TMJ. Although the effective dose of the lateral view in Panoramic TMJ was 3 times higher than that of the small exposure field (10 x 10 cm on film) in Schueller's method, it was the same as that of a mid-sized exposure field. When the exposure field in the inferior 1/3 was reduced during panoramic TMJ, the effective doses could be decreased. Therefore we recommend that the size of the exposure field in Panoramic TMJ be decreased. (author)

  10. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  11. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  12. Measurement of radiation dose in multi-slice computed tomography

    OpenAIRE

    Surendra Maharjan; Sudil Prajapati; Om Biju Panta

    2016-01-01

    The aim of this study was to measure the radiation doses for computed tomography (CT) examinations of the head, chest and abdomen in adult patients in Nepal in comparison to international standard. Dose length products (DLP) and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIVol). Details were obtained from approximately 90 CT examinations carried out in 128 slice CT scan. Effective dose was calculated for each examination using CT dose ...

  13. Vancomycin dosing and target attainment in children.

    Science.gov (United States)

    Hwang, David; Chiu, Nan-Chang; Chang, Lung; Peng, Chun-Chih; Huang, Daniel Tsung-Ning; Huang, Fu-Yuan; Chi, Hsin

    2017-08-01

    The aim of this study is to determine the best dosing strategy for vancomycin by studying the associated factors and examining correlations between the area under the plasma concentration-time curve (AUC) values and trough concentrations in children. Children aged 3 months to 18 years were included if they received vancomycin for more than three doses between January 1, 2010 and December 31, 2012 and had one or more serum vancomycin trough concentrations. Vancomycin clearance (CL) was calculated using the following model: CL = 0.248*Wt 0.75 *(0.48/serum creatinine) 0.361 *[ln (age)/7.8] 0.995 . The AUC (mg-h/L) was calculated by 24-hour dose (mg/kg/d)/CL(L/h). The value of AUC divided by the minimum inhibitory concentration (MIC) of vancomycin was AUC/MIC. A total of 218 children were included. The mean age was 6.0 ± 5.1 years and the mean body weight was 20 ± 11.7 kg. Vancomycin trough concentrations were moderately correlated with AUC values (r 2  = 0.232, p vancomycin trough concentrations (p < 0.001) compared to dosing of 10 mg/kg/dose q6h. In children receiving a 10-mg/kg/dose q6h, 5.6% (5/90) achieved the target trough concentrations of 15-20 μg/mL and 9.5% (5/90) achieved the goal AUC/MIC ≥ 400. In children receiving a 15-mg/kg/dose q6h, 13% (6/46) achieved the target trough concentrations of 15-20 μg/mL, whereas 54.3% (25/46) achieved the goal AUC/MIC ≥ 400. A 15-mg/kg/dose q6h compared to a 10-mg/kg/dose q6h is more likely to achieve target trough concentrations of 15-20 μg/mL and the goal AUC/MIC ≥ 400. Copyright © 2015. Published by Elsevier B.V.

  14. Computing effective dose in cardiac CT

    Science.gov (United States)

    Huda, Walter; Tipnis, Sameer; Sterzik, Alexander; Schoepf, U. Joseph

    2010-07-01

    We present a method of estimating effective doses in cardiac CT that accounts for selected techniques (kV mAs-1), anatomical location of the scan and patient size. A CT dosimetry spreadsheet (ImPACT CT Patient Dosimetry Calculator) was used to estimate effective doses (E) using ICRP 103 weighting factors for a 70 kg patient undergoing cardiac CT examinations. Using dose length product (DLP) for the same scans, we obtained values of E/DLP for three CT scanners used in cardiac imaging from two vendors. E/DLP ratios were obtained as a function of the anatomical location in the chest and for x-ray tube voltages ranging from 80 to 140 kV. We also computed the ratio of the average absorbed dose in a water cylinder modeling a patient weighing W kg to the corresponding average absorbed dose in a water cylinder equivalent to a 70 kg patient. The average E/DLP for a 16 cm cardiac heart CT scan was 26 µSv (mGy cm)-1, which is about 70% higher than the current E/DLP values used for chest CT scans (i.e. 14-17 µSv (mGy cm)-1). Our cardiac E/DLP ratios are higher because the cardiac region is ~30% more radiosensitive than the chest, and use of the ICRP 103 tissue weighting factors increases cardiac CT effective doses by ~30%. Increasing the x-ray tube voltage from 80 to 140 kV increases the E/DLP conversion factor for cardiac CT by 17%. For the same incident radiation at 120 kV, doses in 45 kg adults were ~22% higher than those in 70 kg adults, whereas doses in 120 kg adults were ~28% lower. Accurate estimates of the patient effective dose in cardiac CT should use ICRP 103 tissue weighting factors, and account for a choice of scan techniques (kV mAs-1), exposed scan region, as well as patient size.

  15. Computing proton dose to irregularly moving targets

    International Nuclear Information System (INIS)

    Phillips, Justin; Gueorguiev, Gueorgui; Grassberger, Clemens; Dowdell, Stephen; Paganetti, Harald; Sharp, Gregory C; Shackleford, James A

    2014-01-01

    Purpose: While four-dimensional computed tomography (4DCT) and deformable registration can be used to assess the dose delivered to regularly moving targets, there are few methods available for irregularly moving targets. 4DCT captures an idealized waveform, but human respiration during treatment is characterized by gradual baseline shifts and other deviations from a periodic signal. This paper describes a method for computing the dose delivered to irregularly moving targets based on 1D or 3D waveforms captured at the time of delivery. Methods: The procedure uses CT or 4DCT images for dose calculation, and 1D or 3D respiratory waveforms of the target position at time of delivery. Dose volumes are converted from their Cartesian geometry into a beam-specific radiological depth space, parameterized in 2D by the beam aperture, and longitudinally by the radiological depth. In this new frame of reference, the proton doses are translated according to the motion found in the 1D or 3D trajectory. These translated dose volumes are weighted and summed, then transformed back into Cartesian space, yielding an estimate of the dose that includes the effect of the measured breathing motion. The method was validated using a synthetic lung phantom and a single representative patient CT. Simulated 4DCT was generated for the phantom with 2 cm peak-to-peak motion. Results: A passively-scattered proton treatment plan was generated using 6 mm and 5 mm smearing for the phantom and patient plans, respectively. The method was tested without motion, and with two simulated breathing signals: a 2 cm amplitude sinusoid, and a 2 cm amplitude sinusoid with 3 cm linear drift in the phantom. The tumor positions were equally weighted for the patient calculation. Motion-corrected dose was computed based on the mid-ventilation CT image in the phantom and the peak exhale position in the patient. Gamma evaluation was 97.8% without motion, 95.7% for 2 cm sinusoidal motion, 95.7% with 3 cm drift in

  16. Computed radiography dose optimization in pediatric patients

    International Nuclear Information System (INIS)

    Juste, B.; Verdu, G.; Tortosa, R.; Villaescusa, J.I.

    2008-01-01

    Radiation dose reduction in pediatric X-ray imaging is especially important because of children radiation sensitivity. For any radiographic examination performed at a fixed radiographic tube potential, the patient absorbed dose is directly proportional to the value of milliampere-seconds (mAs) selected by the operator. Nevertheless, reducing X-ray exposure has the unavoidable disadvantage of increasing the quantum noise in the resultant image. The objective of this work is to identify the minimum tube current setting required for maintaining accurate examinations, to modify, if required, the daily protocols applied at La Fe de Valencia Universitary Hospital. To accomplish this goal, a noise addition software has been developed in order to study the diagnostic accuracy as a function of reducing dose by artificially increasing the image noise. The noise addition tool has been applied to several thorax images acquired from pediatric unit to simulate new lower dose radiographies and allow medical researchers to study how lower dose affects the patient pneumonia diagnosis. (author)

  17. Exposure doses to angiographers during interventional angiography

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yasuhara, Yoshifumi; Sugata, Shigenori; Fujii, Takashi; Kawakami, Toshiaki; Ikezoe, Junpei

    1997-01-01

    We report the exposure doses to angiographers during interventional angiography and the protective efficacy of protective aprons against X-rays in this study. The first (main) angiographer was exposed to the maximum dose of 1 μSv/min at the left chest area and lower abdominal area inside the protective apron. The second (assistant) angiographer was exposed to the maximum dose of 2 μSv/min at the left chest area and 1 μSv/min at the lower abdominal area. X-ray transmission ratio of the protective apron was 4.9 percent or less for UL25L, O percent for 0.35 mmPb and 4.3 percent or less for 0.5 mmPb. These results were lower than the dose equivalent limit based on the laws and ordinances. The protection capacities of these protective aprons proved to be sufficient. The exposure dose at the left extremity area outside the protective apron, however, was 24 times higher than at the left chest area inside. The data showed that it was not protected from scattered X-rays outside the protective apron. It is imperative to consider secondary protective material for the area outside the protective apron. Considering the risk of radiation, we need to better control exposure to angiographers. (author)

  18. Absorbed doses to patients from angioradiology

    International Nuclear Information System (INIS)

    Rodriguez-Romero, R.; Hernandez-Armas, J.; Diaz-Romero, F.

    2001-01-01

    The aim of study was to know patients doses exposes when three different procedures of angioradiology were carried out. The explorations considered were drainage biliary, varicocele embolization and dacriocistography made in the Radiodiagnostic Service at the University Hospital of Canary Islands, Tenerife (Spain). In total 14 patients were studied. The measurements were made using large area transmission ionisation chamber which gives the values of Dose Area Product (DAP). In addition, thermoluminescent dosimeters type TLD-100 were used in anthropomorphic phantom in order to obtain values of organ doses when the phantom was submitted to the same procedures rather than the actual patients. Furthermore, the Effdose program was used to estimate the effective doses in the procedures conditions. The values for DAP were in the range of 70-300 for drainage biliary, 43-180 for varicocele embolization and 1.4-9 for dacriocistography. The organ doses measured with TLD-100 were higher than the corresponding values estimated by Effdose program. The results for varicocele embolization were higher than other published data. In the case of drainage biliary procedure, the values were closed to other published results. It was not possible to find data for dacriocistography from other authors. (author)

  19. Agriculture-related radiation dose calculations

    International Nuclear Information System (INIS)

    Furr, J.M.; Mayberry, J.J.; Waite, D.A.

    1987-10-01

    Estimates of radiation dose to the public must be made at each stage in the identification and qualification process leading to siting a high-level nuclear waste repository. Specifically considering the ingestion pathway, this paper examines questions of reliability and adequacy of dose calculations in relation to five stages of data availability (geologic province, region, area, location, and mass balance) and three methods of calculation (population, population/food production, and food production driven). Calculations were done using the model PABLM with data for the Permian and Palo Duro Basins and the Deaf Smith County area. Extra effort expended in gathering agricultural data at succeeding environmental characterization levels does not appear justified, since dose estimates do not differ greatly; that effort would be better spent determining usage of food types that contribute most to the total dose; and that consumption rate and the air dispersion factor are critical to assessment of radiation dose via the ingestion pathway. 17 refs., 9 figs., 32 tabs

  20. Dose limits to the eye lens

    Energy Technology Data Exchange (ETDEWEB)

    Sion, N.

    2016-09-15

    Protecting the human body from the effects of ionizing radiation is essential to forestall stochastic effects and require placing limits on the effective dose. Dose limits on specific organs are also necessary to reduce the deterministic effects and tissue reactions. The standard for radiation protection was ISO 15382 (2002) which mainly dealt with beta radiation for nuclear power plant workers. Clearly an update is required to allow for new technology and the proliferative use of radiation in medical practices. There is a need for more explicit radiation monitoring to operators and staff. ICRP118 (International Commission on Radiological Protection), Ref. 1, evolved their recommendations to include eye lens doses as a follow on to their publication 103 and to focus on radiation exposures. It provides updated estimates of 'practical' threshold doses for tissue injury at the level of 1% incidence. This paper discusses the current status and the recommendation for a drastic reduction of the dose limit to the eye lens. (author)

  1. Evaluation of doses in gastrointestinal fluoroscopy

    International Nuclear Information System (INIS)

    Canevaro, Lucia Viviana

    1995-04-01

    This work aims at the development of a methodology to measure radiation doses to patients and professionals (radiologists) in fluoroscopic gastrointestinal tract examinations. Also, it aims at the assessment of the performance of this type of medical x-ray equipment, from the radiation protection point of view at the Department of Radiology of the Hospital Universitario Clementino Fraga Filho (Universidade Federal de Rio de Janeiro). This work was developed in order to identify the actual status and to set base lines as a reference for a quality control program. The calibration procedures of thermoluminescent dosimeters for radiodiagnosis quality beams are discussed and described here as well as its application in dose measurements, for patients and radiologists. The performance of two types of x-ray equipment (fluorescent screen and image intensifier) usually used to perform this examinations was evaluated through appropriate tests. Radiation protection features are also considered. Dose to radiologists at unprotected regions and to patients at several sample points were measured. A comparison of the measured doses given by both types of equipment was made. After further analysis, the necessity to look for methods that reduce unnecessary doses became evident. The high values obtained in some procedures using fluorescent screen make the use of this type of equipment unacceptable. With these results, we consider that Health Care authorities have the responsibility of replacing all fluorescent screen equipment and of establishing standards, and raising awareness the responsible staff. (author)

  2. Assessment of radiation dose awareness among pediatricians

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Karen E.; Parnell-Parmley, June E.; Charkot, Ellen; BenDavid, Guila; Krajewski, Connie [The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, Ontario (Canada); Haidar, Salwa [Mubarak Al-Kabeer Hospital, Department of Radiology, Salmiya (Kuwait); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada)

    2006-08-15

    There is increasing awareness among pediatric radiologists of the potential risks associated with ionizing radiation in medical imaging. However, it is not known whether there has been a corresponding increase in awareness among pediatricians. To establish the level of awareness among pediatricians of the recent publicity on radiation risks in children, knowledge of the relative doses of radiological investigations, current practice regarding parent/patient discussions, and the sources of educational input. Multiple-choice survey. Of 220 respondents, 105 (48%) were aware of the 2001 American Journal of Roentgenology articles on pediatric CT and radiation, though only 6% were correct in their estimate of the quoted lifetime excess cancer risk associated with radiation doses equivalent to pediatric CT. A sustained or transient increase in parent questioning regarding radiation doses had been noticed by 31%. When estimating the effective doses of various pediatric radiological investigations in chest radiograph (CXR) equivalents, 87% of all responses (and 94% of CT estimates) were underestimates. Only 15% of respondents were familiar with the ALARA principle. Only 14% of pediatricians recalled any relevant formal teaching during their specialty training. The survey response rate was 40%. Awareness of radiation protection issues among pediatricians is generally low, with widespread underestimation of relative doses and risks. (orig.)

  3. Dose assessment for Greifswald and Cadarache

    International Nuclear Information System (INIS)

    Raskob, W.

    1996-07-01

    Probabilistic dose assessments for accidental atmospheric releases of tritium and activation products as well as releases under normal operation conditions were performed for the sites of Greifswald, Germany, and Cadarache, France. Additionally, aquatic releases were considered for both sites. No country specific rules were applied and the input parameters were adapted as far as possible to those used within former ITER studies to have a better comparison to site independent dose assessments performed in the frame of ITER. The main goal was to complete the generic data base with site specific values. The agreement between the results from the ITER study on atmospheric releases and the two sites are rather good for tritium, whereas the ITER reference dose values for the activation product releases are often lower, than the maximum doses for Greifswald and Cadarache. However, the percentile values fit better to the deterministic approach of ITER. Within all scenarios, the consequences of aquatic releases are in nearly all cases smaller than those from comparable releases to the atmosphere (HTO and steel). This rule is only broken once in case of accidental releases of activated steel from Cadarache. However, the uncertainties associated with the aquatic assessments are rather high and a better data base is needed to obtain more realistic and thus more reliable dose values. (orig.) [de

  4. Dose optimisation in single plane interstitial brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte

    2006-01-01

    BACKGROUND AND PURPOSE: Brachytherapy dose distributions can be optimised       by modulation of source dwell times. In this study dose optimisation in       single planar interstitial implants was evaluated in order to quantify the       potential benefit in patients. MATERIAL AND METHODS: In 14...... patients,       treated for recurrent rectal and cervical cancer, flexible catheters were       sutured intra-operatively to the tumour bed in areas with compromised       surgical margin. Both non-optimised, geometrically and graphically       optimised CT -based dose plans were made. The overdose index...... (OI),       homogeneity index (HI), conformal index (COIN), minimum target dose, and       high dose volumes were evaluated. The dependence of OI, HI, and COIN on       target volume and implant regularity was evaluated. In addition, 12       theoretical implant configurations were analyzed. RESULTS...

  5. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  6. Patient radiation dose during mammography procedures

    International Nuclear Information System (INIS)

    Mohamed, Swsan Awd Elkriem

    2015-11-01

    The objectives of this study were to estimate the patient dose in term of mean glandular dose and assist in optimization of radiation protection in mammographic procedures in Sudan. A total number of 107 patients were included. Four mammographic units were participated. Only one center was using automatic exposure control (AEC). The mean doses in (mGy) for the CC projection were 3.13, 1.24, 2.45 and 0.98 and for the MLO projection was 2.13, 1.26, 1.99 and 1.02 for centers A, B, C, and D, respectively. The total mean dose per breast from both projections was 5.26, 2.50, 4.44 and 1.99 mGy for centers A, B, C and D, respectively. The minimum mean glandular dose was found between the digital system which was operated under AEC and one of the manual selected exposure factors systems, this highlight possible optimization of radiation protection in the other manual selected systems. The kilo volt and the tube current time products should be selected correctly according to the breast thickness in both centers A and C. (author)

  7. Evaluation of radiation doses from radioactive drugs

    International Nuclear Information System (INIS)

    Halperin, J.A.; Grove, G.R.

    1977-01-01

    Radioactive new drugs are regulated by the Food and Drug Administration (FDA) in the United States. Before a new drug can be marketed it must have an approved New Drug Application (NDA). Clinical investigations of a radioactive new drug are carried out under a Notice of Claimed Investigational Exemption for a New Drug (IND), submitted to the FDA. In the review of the IND, radiation doses are projected on the basis of experimental data from animal models and from calculations based upon radiation characteristics, predicted biodistribution of the drug in humans, and activity to be administered. FDA physicians review anticipated doses and prevent clinical investigations in humans when the potential risk of the use of a radioactive substance outweighs the prospect of achieving beneficial results from the administration of the drug. In the evaluation of an NDA, FDA staff attempt to assure that the intended diagnostic or therapeutic effect is achievable with the lowest practicable radiation dose. Radiation doses from radioactive new drugs are evaluated by physicians within the FDA. Important radioactive new drugs are also evaluated by the Radiopharmaceuticals Advisory Committee. FDA also supports the Center for Internal Radiation Dosimetry at Oak Ridge, to provide information regarding in vivo distribution and dosimetry to critical organs and the whole body from radioactive new drugs. The process for evaluation of radiation doses from radioactive new drugs for protection against use of unnecessary radiation exposure by patients in nuclear medicine procedures, a

  8. Iterative reconstruction reduces abdominal CT dose

    International Nuclear Information System (INIS)

    Martinsen, Anne Catrine Trægde; Sæther, Hilde Kjernlie; Hol, Per Kristian; Olsen, Dag Rune; Skaane, Per

    2012-01-01

    Objective: In medical imaging, lowering radiation dose from computed tomography scanning, without reducing diagnostic performance is a desired achievement. Iterative image reconstruction may be one tool to achieve dose reduction. This study reports the diagnostic performance using a blending of 50% statistical iterative reconstruction (ASIR) and filtered back projection reconstruction (FBP) compared to standard FBP image reconstruction at different dose levels for liver phantom examinations. Methods: An anthropomorphic liver phantom was scanned at 250, 185, 155, 140, 120 and 100 mA s, on a 64-slice GE Lightspeed VCT scanner. All scans were reconstructed with ASIR and FBP. Four readers evaluated independently on a 5-point scale 21 images, each containing 32 test sectors. In total 672 areas were assessed. ROC analysis was used to evaluate the differences. Results: There was a difference in AUC between the 250 mA s FBP images and the 120 and 100 mA s FBP images. ASIR reconstruction gave a significantly higher diagnostic performance compared to standard reconstruction at 100 mA s. Conclusion: A blending of 50–90% ASIR and FBP may improve image quality of low dose CT examinations of the liver, and thus give a potential for reducing radiation dose.

  9. Hanford Environmental Dose Reconstruction Project. Monthly report

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S. M.; McMakin, A. H.

    1991-09-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation dose that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is divided into five technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (i.e., dose estimates). The Source Terms Task develops estimates of radioactive emissions from Hanford facilities since 1944. The Environmental Transport Task reconstructs the movements of radioactive particles from the areas of release to populations. The Environmental Monitoring Data Task assemblies, evaluates and reports historical environmental monitoring data. The Demographics, Agriculture and Food Habits Task develops the data needed to identify the populations that could have been affected by the releases. The Environmental Pathways and Dose Estimates Task used the information derived from the other Tasks to estimate the radiation doses individuals could have received from Hanford radiation. This document lists the progress on this project as of September 1991. 3 figs., 2 tabs.

  10. Microdosimetric approach for lung dose assessments

    International Nuclear Information System (INIS)

    Hofmann, W.; Steinhausler, F.; Pohl, E.; Bernroider, G.

    1980-01-01

    In the macroscopic region the term ''organ dose'' is related to an uniform energy deposition within a homogeneous biological target. Considering the lung, inhaled radioactive nuclides, however, show a significant non-uniform distribution pattern throughout the respiratory tract. For the calculation of deposition and clearance of inhaled alpha-emitting radionuclides within different regions of this organ, a detailed compartment model, based on the Weibel model A was developed. Since biological effects (e.g. lung cancer initiation) are primarily caused at the cellular level, the interaction of alpha particles with different types of cells of the lung tissue was studied. The basic approach is to superimpose alpha particle tracks on magnified images of randomly selected tissue slices, simulating alpha emitting sources. Particle tracks are generated by means of a specially developed computer program and used as input data for an on-line electronic image analyzer (Quantimet-720). Using adaptive pattern recognition methods the different cells in the lung tissue can be identified and their distribution within the whole organ determined. This microdosimetric method is applied to soluble radon decay products as well as to insoluble, highly localized, plutonium particles. For a defined microdistribution of alpha emitters, the resulting dose, integrated over all cellular dose values, is compared to the compartmental doses of the ICRP lung model. Furthermore this methodology is also applicable to other organs and tissues of the human body for dose calculations in practical health physics. (author)

  11. Assessment of radiation dose awareness among pediatricians

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Parnell-Parmley, June E.; Charkot, Ellen; BenDavid, Guila; Krajewski, Connie; Haidar, Salwa; Moineddin, Rahim

    2006-01-01

    There is increasing awareness among pediatric radiologists of the potential risks associated with ionizing radiation in medical imaging. However, it is not known whether there has been a corresponding increase in awareness among pediatricians. To establish the level of awareness among pediatricians of the recent publicity on radiation risks in children, knowledge of the relative doses of radiological investigations, current practice regarding parent/patient discussions, and the sources of educational input. Multiple-choice survey. Of 220 respondents, 105 (48%) were aware of the 2001 American Journal of Roentgenology articles on pediatric CT and radiation, though only 6% were correct in their estimate of the quoted lifetime excess cancer risk associated with radiation doses equivalent to pediatric CT. A sustained or transient increase in parent questioning regarding radiation doses had been noticed by 31%. When estimating the effective doses of various pediatric radiological investigations in chest radiograph (CXR) equivalents, 87% of all responses (and 94% of CT estimates) were underestimates. Only 15% of respondents were familiar with the ALARA principle. Only 14% of pediatricians recalled any relevant formal teaching during their specialty training. The survey response rate was 40%. Awareness of radiation protection issues among pediatricians is generally low, with widespread underestimation of relative doses and risks. (orig.)

  12. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    Science.gov (United States)

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After

  13. Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate

    International Nuclear Information System (INIS)

    Karuppasamy, Manikandan; Karimi Nejadasl, Fatemeh; Vulovic, Milos; Koster, Abraham J.; Ravelli, Raimond B. G.

    2011-01-01

    The effects of dose and dose-rate were investigated for single-particle cryo-electron microscopy using stroboscopic data collection. A dose-rate effect was observed favoring lower flux densities. Radiation damage is an important resolution limiting factor both in macromolecular X-ray crystallography and cryo-electron microscopy. Systematic studies in macromolecular X-ray crystallography greatly benefited from the use of dose, expressed as energy deposited per mass unit, which is derived from parameters including incident flux, beam energy, beam size, sample composition and sample size. In here, the use of dose is reintroduced for electron microscopy, accounting for the electron energy, incident flux and measured sample thickness and composition. Knowledge of the amount of energy deposited allowed us to compare doses with experimental limits in macromolecular X-ray crystallography, to obtain an upper estimate of radical concentrations that build up in the vitreous sample, and to translate heat-transfer simulations carried out for macromolecular X-ray crystallography to cryo-electron microscopy. Stroboscopic exposure series of 50–250 images were collected for different incident flux densities and integration times from Lumbricus terrestris extracellular hemoglobin. The images within each series were computationally aligned and analyzed with similarity metrics such as Fourier ring correlation, Fourier ring phase residual and figure of merit. Prior to gas bubble formation, the images become linearly brighter with dose, at a rate of approximately 0.1% per 10 MGy. The gradual decomposition of a vitrified hemoglobin sample could be visualized at a series of doses up to 5500 MGy, by which dose the sample was sublimed. Comparison of equal-dose series collected with different incident flux densities showed a dose-rate effect favoring lower flux densities. Heat simulations predict that sample heating will only become an issue for very large dose rates (50 e − Å −2 s

  14. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  15. Radiation dose metrics in CT: assessing dose using the National Quality Forum CT patient safety measure.

    Science.gov (United States)

    Keegan, Jillian; Miglioretti, Diana L; Gould, Robert; Donnelly, Lane F; Wilson, Nicole D; Smith-Bindman, Rebecca

    2014-03-01

    The National Quality Forum (NQF) is a nonprofit consensus organization that recently endorsed a measure focused on CT radiation doses. To comply, facilities must summarize the doses from consecutive scans within age and anatomic area strata and report the data in the medical record. Our purpose was to assess the time needed to assemble the data and to demonstrate how review of such data permits a facility to understand doses. To assemble the data we used for analysis, we used the dose monitoring software eXposure to automatically export dose metrics from consecutive scans in 2010 and 2012. For a subset of 50 exams, we also collected dose metrics manually, copying data directly from the PACS into an excel spreadsheet. Manual data collection for 50 scans required 2 hours and 15 minutes. eXposure compiled the data in under an hour. All dose metrics demonstrated a 30% to 50% reduction between 2010 and 2012. There was also a significant decline and a reduction in the variability of the doses over time. The NQF measure facilitates an institution's capacity to assess the doses they are using for CT as part of routine practice. The necessary data can be collected within a reasonable amount of time either with automatic software or manually. The collection and review of these data will allow facilities to compare their radiation dose distributions with national distributions and allow assessment of temporal trends in the doses they are using. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Effect of Dose Rate Variation on Dose Distribution in IMRT with a Dynamic Multileaf Collimator

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kyoung Dal; Jae, Young Wan; Yoon, Il Kyu; Lee, Jae Hee; Yoo, Suk Hyun [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2012-03-15

    To evaluate dose distribution differences when the dose rates are randomly changed in intensity-modulated radiation therapy using a dynamic multileaf collimator. Two IMRT treatment plans including small-field and large-field plans were made using a commercial treatment planning system (Eclipse, Varian, Palo Alto, CA). Each plan had three sub-plans according to various dose rates of 100, 400, and 600 MU/min. A chamber array (2D-Array Seven729, PTW-Freiburg) was positioned between solid water phantom slabs to give measurement depth of 5 cm and backscattering depth of 5 cm. Beam deliveries were performed on the array detector using a 6 MV beam of a linear accelerator (Clinac 21EX, Varian, Palo Alto, CA) equipped with 120-leaf MLC (Millenium 120, Varian). At first, the beam was delivered with same dose rates as planned to obtain reference values. After the standard measurements, dose rates were then changed as follows: 1) for plans with 100 MU/min, dose rate was varied to 200, 300, 400, 500 and 600 MU/min, 2) for plans with 400 MU/min, dose rate was varied to 100, 200, 300, 500 and 600 MU/min, 3) for plans with 600 MU/min, dose rate was varied to 100, 200, 300, 400 and 500 MU/min. Finally, using an analysis software (Verisoft 3.1, PTW-Freiburg), the dose difference and distribution between the reference and dose-rate-varied measurements was evaluated. For the small field plan, the local dose differences were -0.8, -1.1, -1.3, -1.5, and -1.6% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +0.9, +0.3, +0.1, -0.2, and -0.2% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.4, +0.8, +0.5, +0.3, and +0.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). On the other hand, for the large field plan, the pass-rate differences were -1.3, -1.6, -1.8, -2.0, and -2.4% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100

  17. The MESORAD dose assessment model: Computer code

    International Nuclear Information System (INIS)

    Ramsdell, J.V.; Athey, G.F.; Bander, T.J.; Scherpelz, R.I.

    1988-10-01

    MESORAD is a dose equivalent model for emergency response applications that is designed to be run on minicomputers. It has been developed by the Pacific Northwest Laboratory for use as part of the Intermediate Dose Assessment System in the US Nuclear Regulatory Commission Operations Center in Washington, DC, and the Emergency Management System in the US Department of Energy Unified Dose Assessment Center in Richland, Washington. This volume describes the MESORAD computer code and contains a listing of the code. The technical basis for MESORAD is described in the first volume of this report (Scherpelz et al. 1986). A third volume of the documentation planned. That volume will contain utility programs and input and output files that can be used to check the implementation of MESORAD. 18 figs., 4 tabs

  18. Radiation Doses to Skin from Dermal Contamination

    Science.gov (United States)

    2010-10-01

    face; spray-wash 1-7 / 5.00 1.6 0.032 19 CFM; forearms; spray-wash plus rubbing 10-6 / 7.00 1.1 0.16 135 CFM; forearms and hands, spray-wash 1-7...skinskin DRFtCtD   where ) = dose rate to skin at time t (rem h–1); ( tD  Cskin(t) = activity concentration of radionuclides on skin at time t...and dose-rate factor are specific to deposition on clothing: (5-1)     clothingclothing DRFtCtD   where )( tD  = dose rate to skin at

  19. Absorbed dose determination in water. I

    International Nuclear Information System (INIS)

    Novotny, J.

    1991-01-01

    The use of new values of physical parameters as recommended by international organizations has consequences in radiotherapy, e.g. in the determination of absorbed doses in water based on ionometric measurements. A procedure is proposed for the determination of the conversion factor K w,u between kerma in air and absorbed dose in water, and of the factor C w,u between exposure measured and absorbed dose in water, for ionization chambers and high-energy photon beams. The conversion factors depend not only on the radiation quality but also on the dimensions and composition of the chamber and of the cup used in the calibrations. Numerical values are given for conventional kinds of ionization chambers. (author). 3 tabs., 16 refs

  20. Dose rate calculations for a reconnaissance vehicle

    International Nuclear Information System (INIS)

    Grindrod, L.; Mackey, J.; Salmon, M.; Smith, C.; Wall, S.

    2005-01-01

    A Chemical Nuclear Reconnaissance System (CNRS) has been developed by the British Ministry of Defence to make chemical and radiation measurements on contaminated terrain using appropriate sensors and recording equipment installed in a land rover. A research programme is under way to develop and validate a predictive capability to calculate the build-up of contamination on the vehicle, radiation detector performance and dose rates to the occupants of the vehicle. This paper describes the geometric model of the vehicle and the methodology used for calculations of detector response. Calculated dose rates obtained using the MCBEND Monte Carlo radiation transport computer code in adjoint mode are presented. These address the transient response of the detectors as the vehicle passes through a contaminated area. Calculated dose rates were found to agree with the measured data to be within the experimental uncertainties, thus giving confidence in the shielding model of the vehicle and its application to other scenarios. (authors)