  1. The calculation of relative output factor and depth dose for irregular electron fields in water

    International Nuclear Information System (INIS)

    Dunscombe, Peter; McGhee, Peter; Chu, Terence

    1996-01-01

    Purpose: A technique, based on sector integration and interpolation, has been developed for the computation of both relative output factor and depth dose of irregular electron fields in water. The purpose of this study was to determine the minimum experimental data set required for the technique to yield results within accepted dosimetric tolerances. Materials and Methods: PC based software has been written to perform the calculations necessary to dosimetrically characterize irregular shaped electron fields. The field outline is entered via digitiser and the SSD and energy via the keyboard. The irregular field is segmented into sectors of specified angle (2 deg. was used for this study) and the radius of each sector computed. The central ray depth dose is reconstructed by summing the contributions from each sector deduced from calibration depth doses measured for circular fields. Relative output factors and depth doses at SSDs at which calibrations were not performed are found by interpolation. Calibration data were measured for circular fields from 2 to 9 cm diameter at 100, 105, 110, and 115 cm SSD. A clinical cut out can be characterized in less than 2 minutes including entry of the outline using this software. The performance of the technique was evaluated by comparing calculated relative output factors, surface dose and the locations of d 80 , d 50 and d 20 with experimental measurements on a variety of cut out shapes at 9 and 18 MeV. The calibration data set (derived from circular cut outs) was systematically reduced to identify the minimum required to yield an accuracy consistent with current recommendations. Results: The figure illustrates the ability of the technique to calculate the depth dose for an irregular field (shown in the insert). It was found that to achieve an accuracy of 2% in relative output factor and 2% or 2 mm (our criterion) in percentage depth dose, calibration data from five circular fields at the four SSDs spanning the range 100-115 cm

  2. Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures

    Science.gov (United States)

    Journy, N; Sinno-Tellier, S; Maccia, C; Le Tertre, A; Pirard, P; Pagès, P; Eilstein, D; Donadieu, J; Bar, O

    2012-01-01

    Objective The study aimed to characterise the factors related to the X-ray dose delivered to the patient's skin during interventional cardiology procedures. Methods We studied 177 coronary angiographies (CAs) and/or percutaneous transluminal coronary angioplasties (PTCAs) carried out in a French clinic on the same radiography table. The clinical and therapeutic characteristics, and the technical parameters of the procedures, were collected. The dose area product (DAP) and the maximum skin dose (MSD) were measured by an ionisation chamber (Diamentor; Philips, Amsterdam, The Netherlands) and radiosensitive film (Gafchromic; International Specialty Products Advanced Materials Group, Wayne, NJ). Multivariate analyses were used to assess the effects of the factors of interest on dose. Results The mean MSD and DAP were respectively 389 mGy and 65 Gy cm−2 for CAs, and 916 mGy and 69 Gy cm−2 for PTCAs. For 8% of the procedures, the MSD exceeded 2 Gy. Although a linear relationship between the MSD and the DAP was observed for CAs (r=0.93), a simple extrapolation of such a model to PTCAs would lead to an inadequate assessment of the risk, especially for the highest dose values. For PTCAs, the body mass index, the therapeutic complexity, the fluoroscopy time and the number of cine frames were independent explanatory factors of the MSD, whoever the practitioner was. Moreover, the effect of technical factors such as collimation, cinematography settings and X-ray tube orientations on the DAP was shown. Conclusion Optimising the technical options for interventional procedures and training staff on radiation protection might notably reduce the dose and ultimately avoid patient skin lesions. PMID:22457404

  3. Dose response and factors related to interstitial pneumonitis after bone marrow transplant

    International Nuclear Information System (INIS)

    Sampath, Sagus; Schultheiss, Timothy E.; Wong, Jeffrey

    2005-01-01

    Purpose: Total body irradiation (TBI) and chemotherapy are common components of conditioning regimens for bone marrow transplantation. Interstitial pneumonitis (IP) is a known regimen-related complication. Using published data of IP in a multivariate logistic regression, this study sought to identify the parameters in the bone marrow transplantation conditioning regimen that were significantly associated with IP and to establish a radiation dose-response function. Methods and Materials: A retrospective review was conducted of articles that reported IP incidence along with lung dose, fractionation, dose rate, and chemotherapy regimen. In the final analysis, 20 articles (n = 1090 patients), consisting of 26 distinct TBI/chemotherapy regimens, were included in the analysis. Multivariate logistic regression was performed to determine dosimetric and chemotherapeutic factors that influenced the incidence of IP. Results: A logistic model was generated from patients receiving daily fractions of radiation. In this model, lung dose, cyclophosphamide dose, and the addition of busulfan were significantly associated with IP. An incidence of 3%-4% with chemotherapy-only conditioning regimens is estimated from the models. The α/β value of the linear-quadratic model was estimated to be 2.8 Gy. The dose eliciting a 50% incidence, D 50 , for IP after 120 mg/kg of cyclophosphamide was 8.8 Gy; in the absence of chemotherapy, the estimated D 50 is 10.6 Gy. No dose rate effect was observed. The use of busulfan as a substitute for radiation is equivalent to treating with 14.8 Gy in 4 fractions with 50% transmission blocks shielding the lung. The logistic regression failed to find a model that adequately fit the multiple-fraction-per-day data. Conclusions: Dose responses for both lung radiation dose and cyclophosphamide dose were identified. A conditioning regimen of 12 Gy TBI in 6 daily fractions induces an IP incidence of about 11% in the absence of lung shielding. Shielding the lung

  4. Factors Associated with Myelosuppression Related to Low-Dose Methotrexate Therapy for Inflammatory Rheumatic Diseases

    Science.gov (United States)

    Mori, Shunsuke; Hidaka, Michihiro; Kawakita, Toshiro; Hidaka, Toshihiko; Tsuda, Hiroyuki; Yoshitama, Tamami; Migita, Kiyoshi; Ueki, Yukitaka

    2016-01-01

    Objective Severe myelosuppression is a serious concern in the management of rheumatic disease patients receiving methotrexate (MTX) therapy. This study was intended to explore factors associated with the development of MTX-related myelosuppression and its disease severity. Methods We retrospectively examined a total of 40 cases of MTX-related myelosuppression that had been filed in the registries of participating rheumatology and hematology divisions. Data before onset were compared with those of 120 controls matched for age and sex. Cytopenia was graded according to the National Cancer Institute criteria for adverse events. Data before and at onset were compared between the severe and non-severe groups. Results Non-use of folic acid supplements, concurrent medications, and low renal function were significantly associated with the development of myelosuppression (p disease severity was not dependent on MTX doses. Serum albumin levels and folic acid supplementation are the important factors affecting the severity of MTX-related pancytopenia and neutropenia. PMID:27128679

  5. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  6. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  7. Software Development for Estimating the Conversion Factor (K-Factor) at Suitable Scan Areas, Relating the Dose Length Product to the Effective Dose.

    Science.gov (United States)

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Syouichi; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi; Kato, Ryouichi

    2017-05-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Software development for estimating the conversion factor (k-factor) at suitable scan areas, relating the dose length product to the effective dose

    International Nuclear Information System (INIS)

    Kobayashi, Masanao; Asada, Yasuki; Suzuki, Syouichi; Kato, Ryouichi; Matsubara, Kosuke; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi

    2017-01-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. (authors)

  9. Determination of photon conversion factors relating exposure and dose for several extremity phantom designs

    International Nuclear Information System (INIS)

    Roberson, P.L.; Eichner, F.N.; Reece, W.D.

    1986-09-01

    This report presents the results of measurements of dosimetric properties of simple extremity phantoms suitable for use in extremity dosimeter performance testing. Two sizes of phantoms were used in this study. One size represented the forearm or lower leg and the other size represented the finger or toe. For both phantom sizes, measurements were performed on solid plastic phantoms and on phantoms containing simulated bone material to determine the effect of backscattered radiations from the bone on the surface dose. Exposure-to-dose conversion factors (C/sub x/ factors) were determined for photon energies ranging from 16 to 1250 keV (average for 60 Co). The effect of the presence of a phantom was also measured for a 90 Sr/ 90 Y source. Significant differences in the measured C/sub x/ factors were found among the phantoms investigated. The factors for the finger-sized phantoms were uniformly less than for the arm-sized phantoms

  10. Patient-related factors determining geometry of intracavitary applicators and pelvic dose distribution during cervical cancer brachytherapy

    International Nuclear Information System (INIS)

    Senkus-Konefka, Elzbieta; Kobierska, Anna; Jassem, Jacek; Badzio, Andrezej

    1997-01-01

    Purpose: The aim of this study was to assess retrospectively the influence of the size of cervical cancer brachytherapy applicators (ovoids and uterine tandems) on pelvic dose distribution and to analyze the impact of various patient-and disease-related factors on applicators' geometry and on dose distribution in particular applications. Methods and Materials: The subject of this study were 356 cervical cancer patients treated with Selectron LDR as a part of their radical radiotherapy. Analyzed factors included patient age, weight, number of vaginal deliveries, and disease stage. Results: The use of larger vaginal applicators resulted in lower bladder and rectum doses and in higher point B doses (all p < 0.0001); longer uterine tandems produced lower rectum doses and higher point B doses (both p < 0.0001). Increasing patient age and disease stage resulted in a decreased frequency of use of large ovoids (both p < 0.0001) and of long tandems (age: p = 0.0069, stage: p = 0.004). As a result, higher doses to bladder (age: p < 0.0001, stage: p = 0.017) and rectum (age: p = 0.037, stage: p = 0.011) were observed. Increasing age also resulted in lower point B doses (p < 0.0001). Increasing patient weight correlated with less frequent use of long tandems (p = 0.0015) and with higher bladder doses (p = 0.04). Higher number of vaginal deliveries was related to the increase in the use of long tandems (p = 0.002); in patients who had had at least one vaginal delivery, point B doses were significantly higher (p = 0.0059). In multivariate analysis ovoid size and uterine tandem length were dependent on patient age (respectively: p < 0.001 and p = 0.001), disease stage (respectively: p = 0.003 and p = 0.008) and on the number of vaginal deliveries (respectively: p = 0.07 and p 0.008). Doses to critical organs and to points B were dependent on patient age (respectively: p < 0.001, p = 0.011, and p < 0.001) and on disease stage (respectively: p < 0.001, p = 0.004, and p = 0

  11. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  12. Quantitative relations between beta-gamma mixed-field dosimeter responses and dose-equivalent conversion factors according to the testing standard

    International Nuclear Information System (INIS)

    Gupta, V.P.

    1982-08-01

    The conventional two-element personnel dosimeters, usually having two thick TLD (thermoluminescent dosimetry) ribbons, are used extensively for radiation protection dosimetry. Many of these dosimeters are used for the measurement of beta and gamma radiation doses received in mixed beta-gamma fields. Severe limitations exist, however, on the relative magnitudes and energies of these fields that may be measured simultaneously. Moreover, due to a well-known energy dependence of these dosimeters, particularly for the beta-radiations, systematic errors will occur whenever the differences in workplaces and calibration radiation energies exist. A simple mathematical approach is presented to estimate the deep and shallow dose equivalent values at different energies for such dosimeters. The formulae correlate the dosimeter responses and dose equivalent conversion factors at different energies by taking into account the guidelines of the adopted ANSI Standard N13.11 and the dosimetry practices followed by most dosimeter processors. This standard is to be used in a mandatory testing program in the United States

  13. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    International Nuclear Information System (INIS)

    D’Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-01-01

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 ± 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 ± 0.42 Gy) were FR ) were 269 Gy cm 2 , 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1–102.7, p FR overexposures (OR 10.8, 95 % CI 1.1–109.5, p FR overexposure (OR 2.8, 95 % CI 1.1–7.4, p = 0.040). At multivariable analysis, stenosis ≥ 90 % (OR 2.8, 95 % CI 1.1–7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1–109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  14. Agriculture-related radiation dose calculations

    International Nuclear Information System (INIS)

    Furr, J.M.; Mayberry, J.J.; Waite, D.A.

    1987-10-01

    Estimates of radiation dose to the public must be made at each stage in the identification and qualification process leading to siting a high-level nuclear waste repository. Specifically considering the ingestion pathway, this paper examines questions of reliability and adequacy of dose calculations in relation to five stages of data availability (geologic province, region, area, location, and mass balance) and three methods of calculation (population, population/food production, and food production driven). Calculations were done using the model PABLM with data for the Permian and Palo Duro Basins and the Deaf Smith County area. Extra effort expended in gathering agricultural data at succeeding environmental characterization levels does not appear justified, since dose estimates do not differ greatly; that effort would be better spent determining usage of food types that contribute most to the total dose; and that consumption rate and the air dispersion factor are critical to assessment of radiation dose via the ingestion pathway. 17 refs., 9 figs., 32 tabs

  15. Disruptive Event Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. A. Wasiolek

    2003-07-21

    the biosphere. The biosphere process model for this scenario uses the surface deposition of contaminated ash as the source of radionuclides in the biosphere. The initial atmospheric transport and dispersion of the ash as well as its subsequent redistribution by fluvial and aeolian processes are not addressed within the biosphere model. The analysis was performed in accordance with the TWP (BSC 2003 [DIRS 163602]). The biosphere model considers features, events, and processes (FEPs) applicable to the Yucca Mountain biosphere (DTN: MO0303SEPFEPS2.000 [DIRS 162452]). The disposition of these FEPs in the TSPA is through the BDCFs which are the direct input to the TSPA model. The disposition of the included FEPs within the biosphere model is documented in the ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]). Specifically, the consideration of the included FEPs in the conceptual model is shown in Table 6.2-1, relationships among the biosphere-related FEPs, the biosphere conceptual model, and the exposure scenarios are more fully examined in Section 6.3, and the disposition of the included FEPs within the mathematical model, and their relationship to the model equations and input parameters is presented in Table 6.7-1 of the ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]). In addition to producing the BDCFs for the volcanic ash exposure scenario, this analysis develops the values of dose factors for calculation of inhalation exposure during a volcanic eruption. The FEPs that were considered in the development of dose factors are listed in Table 1-1. The disposition of these FEPs in TSPA is through the dose factors that are the input to the TSPA model.

  16. Disruptive Event Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M. A. Wasiolek

    2003-01-01

    model for this scenario uses the surface deposition of contaminated ash as the source of radionuclides in the biosphere. The initial atmospheric transport and dispersion of the ash as well as its subsequent redistribution by fluvial and aeolian processes are not addressed within the biosphere model. The analysis was performed in accordance with the TWP (BSC 2003 [DIRS 163602]). The biosphere model considers features, events, and processes (FEPs) applicable to the Yucca Mountain biosphere (DTN: MO0303SEPFEPS2.000 [DIRS 162452]). The disposition of these FEPs in the TSPA is through the BDCFs which are the direct input to the TSPA model. The disposition of the included FEPs within the biosphere model is documented in the ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]). Specifically, the consideration of the included FEPs in the conceptual model is shown in Table 6.2-1, relationships among the biosphere-related FEPs, the biosphere conceptual model, and the exposure scenarios are more fully examined in Section 6.3, and the disposition of the included FEPs within the mathematical model, and their relationship to the model equations and input parameters is presented in Table 6.7-1 of the ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]). In addition to producing the BDCFs for the volcanic ash exposure scenario, this analysis develops the values of dose factors for calculation of inhalation exposure during a volcanic eruption. The FEPs that were considered in the development of dose factors are listed in Table 1-1. The disposition of these FEPs in TSPA is through the dose factors that are the input to the TSPA model

  17. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    Energy Technology Data Exchange (ETDEWEB)

    D' Ercole, Loredana, E-mail: l.dercole@smatteo.pv.it [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Quaretti, Pietro; Cionfoli, Nicola [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Klersy, Catherine [Fondazione IRCCS Policlinico San Matteo, Biometry and Clinical Epidemiology Service, Research Department, (Italy); Bocchiola, Milena [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Rodolico, Giuseppe; Azzaretti, Andrea [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Lisciandro, Francesco [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Cascella, Tommaso; Zappoli Thyrion, Federico [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy)

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  18. The impact of radiotherapy dose and other treatment-related and clinical factors on control of stage I and II non-Hodgkin's lymphoma in irradiated sites

    International Nuclear Information System (INIS)

    Kamath, Sachin S.; Marcus, Robert B.; Lynch, James W.; Mendenhall, Nancy Price

    1997-01-01

    Purpose/Objective: To study the effect of radiotherapeutic and chemotherapeutic parameters on local or in-field (IF) disease control; to identify other treatment-related and clinical factors of potential prognostic significance, and to elucidate the optimal radiotherapy dose in various clinical settings. Materials and Methods: Two hundred eighty-five patients with non-CNS presentations of Stage I and II non-Hodgkin's lymphoma (NHL) were treated with either radiotherapy (RT) alone (n=159) or combined modality therapy (CMT) using induction chemotherapy followed by consolidative RT (n=126). Ninety-three percent (67 of 72 patients) with low grade lymphomas (LGLs) were treated with RT alone. Ninety-two of 213 patients with intermediate/high grade lymphomas (I/HGLs) were treated with RT alone and 121 received CMT. Ninety-one patients (72%) of those receiving CMT were given four or more cycles of chemotherapy; CHOP was the regimen used most often (n=81). The RT treatment volumes included involved field (n=151), extended field (n=123), and comprehensive lymphatic irradiation (n=11). Minimum follow-up was 2 yr (median, 6.5 yr). Variables of potential prognostic significance for IF disease control, freedom from relapse (FFR), and absolute survival (AS) were evaluated by both univariate and multivariate analyses. Results: The 5, 10, and 20 yr actuarial AS rates were 73%, 46%, and 33% for patients with LGL; and 64%, 44%, and 18% for patients with I/HGL, respectively. The 5, 10, and 20 yr actuarial FFR rates were 62%, 59%, and 49% for LGLs and 66%, 57%, and 57% for I/HGLs, respectively. Significant prognostic factors identified by the multivariate analysis were age, tumor size, and histology for AS; tumor size and treatment modality (RT alone vs. CMT) for FFR; and only tumor size for IF disease control. Of the 95 total failures, only 12 were IF. Most of the failures (65%) were observed in contiguous unirradiated sites. All 4 IF failures in the LGLs occurred in patients treated

  19. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    Wasiolek, M.

    2000-01-01

    The purpose of this report was to document the process leading to development of the Biosphere Dose Conversion Factors (BDCFs) for the postclosure nominal performance of the potential repository at Yucca Mountain. BDCF calculations concerned twenty-four radionuclides. This selection included sixteen radionuclides that may be significant nominal performance dose contributors during the compliance period of up to 10,000 years, five additional radionuclides of importance for up to 1 million years postclosure, and three relatively short-lived radionuclides important for the human intrusion scenario. Consideration of radionuclide buildup in soil caused by previous irrigation with contaminated groundwater was taken into account in the BDCF development. The effect of climate evolution, from the current arid conditions to a wetter and cooler climate, on the BDCF values was evaluated. The analysis included consideration of different exposure pathway's contribution to the BDCFs. Calculations of nominal performance BDCFs used the GENII-S computer code in a series of probabilistic realizations to propagate the uncertainties of input parameters into the output. BDCFs for the nominal performance, when combined with the concentrations of radionuclides in groundwater allow calculation of potential radiation doses to the receptor of interest. Calculated estimates of radionuclide concentration in groundwater result from the saturated zone modeling. The integration of the biosphere modeling results (BDCFs) with the outcomes of the other component models is accomplished in the Total System Performance Assessment (TSPA) to calculate doses to the receptor of interest from radionuclides postulated to be released to the environment from the potential repository at Yucca Mountain

  20. Fatigue and Relating Factors in High-Risk Breast Cancer Patients Treated With Adjuvant Standard or High-Dose Chemotherapy: A Longitudinal Study

    NARCIS (Netherlands)

    Nieboer, P.; Buijs, C.; Rodenhuis, S.; Seynaeve, C.; Beex, L.V.A.M.; Wall, E. van der; Richel, D.J.; Nooij, M.A.; Voest, E.E.; Hupperets, P.; Mulder, N.H.; Graaf, W.T.A. van der; TenVergert, E.M.; Tinteren, H. van; Vries, E.G.E. de

    2005-01-01

    PURPOSE Determine whether standard or high-dose chemotherapy leads to changes in fatigue, hemoglobin (Hb), mental health, muscle and joint pain, and menopausal status from pre- to posttreatment and to evaluate whether fatigue is associated with these factors in disease-free breast cancer patients.

  1. Fatigue and relating factors in high-risk breast cancer patients treated with adjuvant standard or high-dose chemotherapy: a longitudinal study.

    NARCIS (Netherlands)

    Nieboer, P.; Buijs, C.; Rodenhuis, S.; Seynaeve, C.; Beex, L.V.A.M.; Wall, E. van der; Richel, D.J.; Nooij, M.A.; Voest, E.E.; Hupperets, P.S.G.J.; Mulder, N.H.; Graaf, W.T.A. van der; Vergert, E.M. ten; Tinteren, H.L.G. van; Vries, E.G.F. de

    2005-01-01

    PURPOSE: Determine whether standard or high-dose chemotherapy leads to changes in fatigue, hemoglobin (Hb), mental health, muscle and joint pain, and menopausal status from pre- to post-treatment and to evaluate whether fatigue is associated with these factors in disease-free breast cancer patients.

  2. Fatigue and relating factors in high-risk breast cancer patients treated with adjuvant standard or high-dose chemotherapy: a longitudinal study

    NARCIS (Netherlands)

    Nieboer, Peter; Buijs, Ciska; Rodenhuis, Sjoerd; Seynaeve, Caroline; Beex, Louk V. A. M.; van der Wall, Elsken; Richel, Dick J.; Nooij, Marianne A.; Voest, Emile E.; Hupperets, Pierre; Mulder, Nanno H.; van der Graaf, Winette T. A.; TenVergert, Els M.; van Tinteren, Harm; de Vries, Elisabeth G. E.

    2005-01-01

    PURPOSE: Determine whether standard or high-dose chemotherapy leads to changes in fatigue, hemoglobin (Hb), mental health, muscle and joint pain, and menopausal status from pre- to post-treatment and to evaluate whether fatigue is associated with these factors in disease-free breast cancer patients.

  3. Fatigue and relating factors in high-risk breast cancer patients treated with adjuvant standard or high-dose chemotherapy : A longitudinal study

    NARCIS (Netherlands)

    Nieboer, P; Buijs, C; Rodenhuis, S; Seynaeve, C; Beex, LVAM; van der Wall, E; Richel, DJ; Nooij, MA; Voest, EE; Hupperets, P; Mulder, NH; van der Graaf, WTA; TenVergert, EM; van Tinteren, H; de Vries, EGE

    2005-01-01

    Purpose Determine whether standard or high-dose chemotherapy leads to changes in fatigue, hemoglobin (Hb), mental health, muscle and joint pain, and menopausal status from pre- to post-treatment and to evaluate whether fatigue is associated with these factors in disease-free breast cancer patients.

  4. Derivation of dose conversion factors for tritium

    Energy Technology Data Exchange (ETDEWEB)

    Killough, G. G.

    1982-03-01

    For a given intake mode (ingestion, inhalation, absorption through the skin), a dose conversion factor (DCF) is the committed dose equivalent to a specified organ of an individual per unit intake of a radionuclide. One also may consider the effective dose commitment per unit intake, which is a weighted average of organ-specific DCFs, with weights proportional to risks associated with stochastic radiation-induced fatal health effects, as defined by Publication 26 of the International Commission on Radiological Protection (ICRP). This report derives and tabulates organ-specific dose conversion factors and the effective dose commitment per unit intake of tritium. These factors are based on a steady-state model of hydrogen in the tissues of ICRP's Reference Man (ICRP Publication 23) and equilibrium of specific activities between body water and other tissues. The results differ by 27 to 33% from the estimate on which ICRP Publication 30 recommendations are based. The report also examines a dynamic model of tritium retention in body water, mineral bone, and two compartments representing organically-bound hydrogen. This model is compared with data from human subjects who were observed for extended periods. The manner of combining the dose conversion factors with measured or model-predicted levels of contamination in man's exposure media (air, drinking water, soil moisture) to estimate dose rate to an individual is briefly discussed.

  5. Derivation of dose conversion factors for tritium

    International Nuclear Information System (INIS)

    Killough, G.G.

    1982-03-01

    For a given intake mode (ingestion, inhalation, absorption through the skin), a dose conversion factor (DCF) is the committed dose equivalent to a specified organ of an individual per unit intake of a radionuclide. One also may consider the effective dose commitment per unit intake, which is a weighted average of organ-specific DCFs, with weights proportional to risks associated with stochastic radiation-induced fatal health effects, as defined by Publication 26 of the International Commission on Radiological Protection (ICRP). This report derives and tabulates organ-specific dose conversion factors and the effective dose commitment per unit intake of tritium. These factors are based on a steady-state model of hydrogen in the tissues of ICRP's Reference Man (ICRP Publication 23) and equilibrium of specific activities between body water and other tissues. The results differ by 27 to 33% from the estimate on which ICRP Publication 30 recommendations are based. The report also examines a dynamic model of tritium retention in body water, mineral bone, and two compartments representing organically-bound hydrogen. This model is compared with data from human subjects who were observed for extended periods. The manner of combining the dose conversion factors with measured or model-predicted levels of contamination in man's exposure media (air, drinking water, soil moisture) to estimate dose rate to an individual is briefly discussed

  6. Considering job-related doses in Europe

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    As part of its role of safeguarding nuclear workers the Commission of the European Community has created a European data bank on job-related doses. The data bank is intended to correlate jobs and workers doses and is a useful instrument to observe the collected doses of workers in nuclear power plants. Set up in 1980, the database covers doses in PWRs and BWRs. To create it a questionnaire is distributed to plant operators. The database responses provide information on (i) Trends in total collective doses, including those for some ancillary jobs. It is possible to see trends by calendar year and by fuel cycle number. (ii) Other trends such as dose in terms of installed power or dose in terms of power station design. (iii) Dose differences between power stations, normalized against the differences in dose rates. This is only possible for PWRs that monitor dose rates using the EPRI standard monitoring programme. (vi) The relative dose rate in each plant for a defined job. The questionnaire is not perfectly adapted to all the working criteria in nuclear power stations but it is an effective tool for implementing radiation protection. (author)

  7. Factors affecting patient dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Poletti, J.L.

    1994-03-01

    The report, Factors Affecting Patient Dose in Diagnostic Radiology is divided into three main sections. Part one is introductory and covers the basic principles of x-ray production and image formation. It includes discussion of x-ray generators and x-ray tubes, radiation properties and units, specification and measurement of x-ray beams, methods of patient dose measurement, radiation effects, radiation protection philosophy and finally the essentials of imaging systems. Part two examines factors affecting the x-ray output of x-ray machines and the characteristics of x-ray beams. These include the influence of heat ratings, kVp, waveform, exposure timer, filtration, focus-film distance, beam intensity distribution, x-ray tube age and focal spot size. Part three examines x-ray machine, equipment and patient factors which affect the dose received by individual patients. The factors considered include justification of examinations, choice of examination method, film/screen combinations, kVp, mAs, focus-film distance, collimation and field size, exposure time, projection, scatter, generator calibration errors, waveform, filtration, film processing and patient size. The patient dose implications of fluoroscopy systems, CT scanners, special procedures and mammography are also discussed. The report concludes with a brief discussion of patient dose levels in New Zealand and dose optimisation. 104 refs., 32 figs., 27 tabs

  8. Proposal concerning the absorbed dose conversion factor

    Energy Technology Data Exchange (ETDEWEB)

    Shiragai, A [National Inst. of Radiological Sciences, Chiba (Japan)

    1978-03-01

    New definitions of the absorbed dose conversion factors Csub(lambda) and Csub(E) are proposed. The absorbed dose in water is given by the product of absorbed dose conversion factor, exposure calibration factor, ionisation chamber reading, cap displacement correction factor and perturbation correction factor. At exposure calibration the material of the build-up cap must be the same as that of the chamber wall. An ionisation chamber of which the wall material is water-equivalent or air-equivalent may be used. In the latter case the wall must be thin. For these two cases absorbed dose conversion factors are introduced and it is recommended that either of the two sets should be adopted. Furthermore, if the chamber wall is neither water- nor air-equivalent, the factor by which these currently defined values should be multiplied is also given: again the wall must be thin. The ICRU definitions of Csub(lambda) and Csub(E) are inconsistent, as recently pointed out, while the definitions presented here are consistent.

  9. The impact of radiotherapy dose and other treatment-related and clinical factors on in-field control in stage I and II non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Kamath, Sachin S.; Marcus, Robert B.; Lynch, James W.; Mendenhall, Nancy Price

    1999-01-01

    Purpose/Objective: To assess local (in-field) disease control, identify potential prognostic factors, and elucidate the optimal radiotherapy dose in various clinical settings of Stage I and II nonHodgkin's lymphoma (non-CNS). Materials and Methods: A total of 285 consecutive patients with Stage I and II non-Hodgkin's lymphoma were treated with curative intent, including 159 with radiotherapy (RT) alone and 126 with combined-modality therapy (CMT). Of these, 72 patients had low-grade lymphomas (LGL), 92 had intermediate or high-grade lymphomas (I/HGL), and 21 had unclassified lymphomas. Clinical and treatment variables with potential prognostic significance for in-field disease control, freedom from relapse (FFR), and absolute survival (AS) were evaluated by univariate and multivariate analyses. Results: The 5-, 10-, and 20-year actuarial AS rates were 73%, 46%, and 33% for patients with LGL and 64%, 44%, and 18% for patients with I/HGL, respectively. The 5-, 10-, and 20-year actuarial FFR rates were 62%, 59%, and 49% for patients with LGL and 66%, 57%, and 57% for patients with I/HGL, respectively. Significant prognostic factors identified by the multivariate analysis were age, tumor size, and histology for AS; tumor size and treatment for FFR; and only tumor size for in-field disease control. There were 95 total failures, with only 12 occurring infield. Most failures (65%) were in contiguous unirradiated sites. All 4 in-field failures in patients with LGL occurred after RT doses 6 cm, and 4 with less than a complete response (CR) to chemotherapy. Conclusion: Our analysis suggests that the overwhelming problem in the treatment of non-Hodgkin's lymphoma is not in-field failure but, rather, failure in contiguous unirradiated sites. A dose of 20-25 Gy may be sufficient for small-volume LGL of the orbit. A dose of 30 Gy is sufficient for LGL in general, as well as for patients with nonbulky (≤ 6 cm) I/HGL treated with CMT who have a CR. However, patients with I

  10. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  11. DISRUPTIVE EVENT BIOSPHERE DOSE CONVERSION FACTOR ANALYSIS

    International Nuclear Information System (INIS)

    M.A. Wasiolek

    2005-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the volcanic ash exposure scenario, and the development of dose factors for calculating inhalation dose during volcanic eruption. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The Biosphere Model Report (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed descriptions of the model input parameters, their development and the relationship between the parameters and specific features, events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the volcanic ash exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and from the five analyses that develop parameter values for the biosphere model (BSC 2005 [DIRS 172827]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; and BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis'' (Figure 1-1). The objective of this analysis was to develop the BDCFs for the volcanic

  12. Nominal Performance Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Wasiolek

    2003-07-25

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standard. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports (BSC 2003 [DIRS 160964]; BSC 2003 [DIRS 160965]; BSC 2003 [DIRS 160976]; BSC 2003 [DIRS 161239]; BSC 2003 [DIRS 161241]) contain detailed description of the model input parameters. This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. The objectives of this analysis are to develop BDCFs and conversion factors for the TSPA. The BDCFs will be used in performance assessment for calculating annual doses for a given concentration of radionuclides in groundwater. The conversion factors will be used for calculating gross alpha particle activity in groundwater and the annual dose from beta- and photon-emitting radionuclides.

  13. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M. Wasiolek

    2004-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standard. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. The objectives of this analysis are to develop BDCFs for the groundwater exposure scenario for the three climate states considered in the TSPA-LA as well as conversion factors for evaluating compliance with the groundwater protection standard. The BDCFs will be used in performance assessment for calculating all-pathway annual doses for a given concentration of radionuclides in groundwater. The conversion factors will be used for calculating gross alpha particle activity in groundwater and the annual dose

  14. Nominal Performance Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Wasiolek

    2005-04-28

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standards. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and the five analyses that develop parameter values for the biosphere model (BSC 2005 [DIRS 172827]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis

  15. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M.A. Wasiolek

    2005-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standards. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and the five analyses that develop parameter values for the biosphere model (BSC 2005 [DIRS 172827]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis'' (Figure 1-1). The objectives of this analysis are to develop BDCFs for the

  16. Disruptive Event Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. Wasiolek

    2004-09-08

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the volcanic ash exposure scenario, and the development of dose factors for calculating inhalation dose during volcanic eruption. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed descriptions of the model input parameters, their development and the relationship between the parameters and specific features, events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the volcanic ash exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and from the five analyses that develop parameter values for the biosphere model (BSC 2004 [DIRS 169671]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; and BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis''. The objective of this

  17. Disruptive Event Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M. Wasiolek

    2004-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the volcanic ash exposure scenario, and the development of dose factors for calculating inhalation dose during volcanic eruption. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed descriptions of the model input parameters, their development and the relationship between the parameters and specific features, events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the volcanic ash exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and from the five analyses that develop parameter values for the biosphere model (BSC 2004 [DIRS 169671]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; and BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis''. The objective of this analysis was to develop the BDCFs for the volcanic ash

  18. A systematic study on factors affecting patient dose, 2

    International Nuclear Information System (INIS)

    Otsuka, Akiyoshi; Higashida, Yoshiharu; Utsumi, Hiromoto; Ota, Masaji; Nakanishi, Takashi

    1979-01-01

    In the preceding report, we dealt with the field size and the tube voltage. This paper covers the differences in patient dose due to the focus to film distance (FFD), the patient thickness and whether the grid is used or not. Regarding the FFD, 100 cm is most commonly employed except in X-ray examinations of the chest, but from the viewpoint of the patient dose, this requires special consideration as to whether there is any theoretical basis for it. The patient thickness has a great bearing on the patient dose, but there is an individual difference, and it is almost impossible to change it artificially. However, there has been no detailed report on the relation between the patient thickness and the patient dose, therefore, this report treats of such relationship as well. Concerning the grid, consideration is given to the exposure times (Bucky factor). (author)

  19. Nominal Performance Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. Wasiolek

    2004-09-08

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standard. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. The objectives of this analysis are to develop BDCFs for the groundwater exposure scenario for the three climate states considered in the TSPA-LA as well as conversion factors for evaluating compliance with the groundwater protection standard. The BDCFs will be used in performance assessment for calculating all-pathway annual doses for a given concentration of radionuclides in groundwater. The conversion factors will be used for calculating gross alpha particle

  20. Ecosystem specific dose conversion factors for Aberg, Beberg and Ceberg

    International Nuclear Information System (INIS)

    Nordlinder, S.; Bergstroem, U.; Mathiasson, Lena

    1999-12-01

    The aim of this study was to calculate ecosystem specific dose conversion factors (EDFs) for three hypothetical sites, Aberg, Beberg and Ceberg, used in the safety analysis SR 97. The EDFs can, in combination with calculated releases of radionuclides from the geosphere, be used to illustrate relative differences in doses to the most exposed individual due to accidental leakage of radionuclides from a deep repository for spent nuclear fuel. Maps of the three sites were studied and subdivided into areas, which were characterised according to an earlier developed module system. For each of the identified modules, ecosystem transport and exposure model calculations were performed for release of 1 Bq per year during 10 000 years. 44 radionuclides contained within a deep repository for spent nuclear fuel were considered. A preliminary comparison of the EDFs for the three sites showed that the highest relative doses can be expected in Ceberg due to the high frequency of peat bog modules

  1. Radon-222 related influence on ambient gamma dose.

    Science.gov (United States)

    Melintescu, A; Chambers, S D; Crawford, J; Williams, A G; Zorila, B; Galeriu, D

    2018-04-03

    Ambient gamma dose, radon, and rainfall have been monitored in southern Bucharest, Romania, from 2010 to 2016. The seasonal cycle of background ambient gamma dose peaked between July and October (100-105 nSv h -1 ), with minimum values in February (75-80 nSv h -1 ), the time of maximum snow cover. Based on 10 m a.g.l. radon concentrations, the ambient gamma dose increased by around 1 nSv h -1 for every 5 Bq m -3 increase in radon. Radon variability attributable to diurnal changes in atmospheric mixing contributed less than 15 nSv h -1 to the overall variability in ambient gamma dose, a factor of 4 more than synoptic timescale changes in air mass fetch. By contrast, precipitation-related enhancements of the ambient gamma dose were 15-80 nSv h -1 . To facilitate routine analysis, and account in part for occasional equipment failure, an automated method for identifying precipitation spikes in the ambient gamma dose was developed. Lastly, a simple model for predicting rainfall-related enhancement of the ambient gamma dose is tested against rainfall observations from events of contrasting duration and intensity. Results are also compared with those from previously published models of simple and complex formulation. Generally, the model performed very well. When simulations underestimated observations the absolute difference was typically less than the natural variability in ambient gamma dose arising from atmospheric mixing influences. Consequently, combined use of the automated event detection method and the simple model of this study could enable the ambient gamma dose "attention limit" (which indicates a potential radiological emergency) to be reduced from 200 to 400% above background to 25-50%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Recommendations on dose buildup factors used in models for calculating gamma doses for a plume

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Thykier-Nielsen, S.

    1980-09-01

    Calculations of external γ-doses from radioactivity released to the atmosphere have been made using different dose buildup factor formulas. Some of the dose buildup factor formulas are used by the Nordic countries in their respective γ-dose models. A comparison of calculated γ-doses using these dose buildup factors shows that the γ-doses can be significantly dependent on the buildup factor formula used in the calculation. Increasing differences occur for increasing plume height, crosswind distance, and atmospheric stability and also for decreasing downwind distance. It is concluded that the most accurate γ-dose can be calculated by use of Capo's polynomial buildup factor formula. Capo-coefficients have been calculated and shown in this report for γ-energies below the original lower limit given by Capo. (author)

  3. Geriatic Disability Related Factors

    Directory of Open Access Journals (Sweden)

    Mohsen Adib Hajbagheri

    2008-07-01

    Full Text Available Objectives: Reports are indicating of increasing trend of aging and disability in the developing countries while such disabilities are decreasing within the developed countries. This study designed to evaluate the disability and some of its related factors among the elderly population (65 and older in Kashan, Iran. Methods & Materials: A cross-sectional analytical study was conducted on a multi-stage random sample of 350 elderly people (65 year and older in Kashan. The WHO-DAS-II was used as the generic disability measure. The questionnair had 48 questions. The range of score could be between 0-144. Chi-square, t-test analysis and ANOVA were utilized to check significant differences between subgroups. Results: 61% were men and 12% were living lonely. One fourth had some type of addiction, the majority were ilitrate and two thired had not regular phisycal activity.Twenty percent of the old people had a modereate disability and 4.3% were extremely disabled. A significant relationship was found between the disability and variables such as sex, age, living style, needing help, marriage status, living location, addiction, job, level of physical activity, education, and having multiple diseases. Conclusion: In conclusion, geriatric population in Iran, has a lower levels of disability in compare to those of other developed countries. Need of geriatric cares must be be increasing, since the populationpattern of elderly people is increasing in Iran. Female and ilitrate elders were sufering of more disability. These findings indicated the nessesity to more attention to these voulnarable subgroups of population.

  4. Dose rate determining factors of PWR primary water

    International Nuclear Information System (INIS)

    Terachi, Takumi; Kuge, Toshiharu; Nakano, Nobuo

    2014-01-01

    The relationship between dose rate trends and water chemistry has been studied to clarify the determining factors on the dose rates. Therefore dose rate trends and water chemistry of 11 PWR plants of KEPCO (Kansai Electric Power Co., Inc.) were summarized. It is indicated that the chemical composition of the oxide film, behaviour of corrosion products and Co-58/Co-60 ratio in the primary system have effected dose rate trends based on plant operation experiences for over 40 years. According to plant operation experiences, the amount of Co-58 has been decreasing with the increasing duration of SG (Steam Generator) usage. It is indicated that the stable oxide film formation on the inner surface of SG tubing, is a major beneficial factor for radiation sources reduction. On the other hand, the reduction of the amount of Co-60 for the long term has been not clearly observed especially in particular high dose plants. The primary water parameters imply that considering release and purification balance on Co-59 is important to prevent accumulation of source term in primary water. In addition, the effect of zinc injection, which relates to the chemical composition of oxide film, was also assessed. As the results, the amount of radioactive Co has been clearly decreased. The decreasing trend seems to correlate to the half-life of Co-60, because it is considered that the injected zinc prevents the uptake of radioactive Co into the oxide film on the inner surface of the components and piping. In this paper, the influence of water chemistry and the replacement experiences of materials on the dose rates were discussed. (author)

  5. Radon: characteristics in air and dose conversion factors

    International Nuclear Information System (INIS)

    Porstendoerfer, J.; Reineking, A.

    1998-01-01

    The dose conversion factor (DCF) which gives the relationship between effective dose and potential alpha energy concentration of inhaled short-lived radon decay products is calculated with a dosimetric approach. The calculations are based on a lung dose model with a structure that is related to the new recommended ICRP respiratory tract model (ICRP 66). The characteristics of the radon decay products concerning the unattached fraction and the activity size distribution of the radon decay products are important input quantities for the calculation of DCF. The experimental data about these quantities obtained from measurements in homes, at work places, and in the free atmosphere near ground in the last past years are reported. The DCF fraction of the unattached (DCF u ) and aerosol-attached (DCF ae ) radon decay products for different places are presented, taking into account the measured characteristics. The influence of the unattached radon daughters on the dose conversion factor DCF u is reported and compared with the DCF ae of the aerosol fraction. (author)

  6. Calculating gamma dose factors for hot particle exposures

    International Nuclear Information System (INIS)

    Murphy, P.

    1990-01-01

    For hot particle exposures to the skin, the beta component of radiation delivers the majority of the dose. However, in order to fully demonstrate regulatory compliance, licenses must ordinarily provide reasonable bases for assuming that both the gamma component of the skin dose and the whole body doses are negligible. While beta dose factors are commonly available in the literature, gamma dose factors are not. This paper describes in detail a method by which gamma skin dose factors may be calculated using the Specific Gamma-ray Constant, even if the particle is not located directly on the skin. Two common hot particle exposure geometries are considered: first, a single square centimeter of skin lying at density thickness of 7 mg/cm 2 and then at 1000 mg/cm 2 . A table provides example gamma dose factors for a number of isotopes encountered at power reactors

  7. Workshop Report on Atomic Bomb Dosimetry--Review of Dose Related Factors for the Evaluation of Exposures to Residual Radiation at Hiroshima and Nagasaki.

    Science.gov (United States)

    Kerr, George D; Egbert, Stephen D; Al-Nabulsi, Isaf; Bailiff, Ian K; Beck, Harold L; Belukha, Irina G; Cockayne, John E; Cullings, Harry M; Eckerman, Keith F; Granovskaya, Evgeniya; Grant, Eric J; Hoshi, Masaharu; Kaul, Dean C; Kryuchkov, Victor; Mannis, Daniel; Ohtaki, Megu; Otani, Keiko; Shinkarev, Sergey; Simon, Steven L; Spriggs, Gregory D; Stepanenko, Valeriy F; Stricklin, Daniela; Weiss, Joseph F; Weitz, Ronald L; Woda, Clemens; Worthington, Patricia R; Yamamoto, Keiko; Young, Robert W

    2015-12-01

    Groups of Japanese and American scientists, supported by international collaborators, have worked for many years to ensure the accuracy of the radiation dosimetry used in studies of health effects in the Japanese atomic bomb survivors. Reliable dosimetric models and systems are especially critical to epidemiologic studies of this population because of their importance in the development of worldwide radiation protection standards. While dosimetry systems, such as Dosimetry System 1986 (DS86) and Dosimetry System 2002 (DS02), have improved, the research groups that developed them were unable to propose or confirm an additional contribution by residual radiation to the survivor's total body dose. In recognition of the need for an up-to-date review of residual radiation exposures in Hiroshima and Nagasaki, a half-day technical session was held for reports on newer studies at the 59 th Annual HPS Meeting in 2014 in Baltimore, MD. A day-and-a-half workshop was also held to provide time for detailed discussion of the newer studies and to evaluate their potential use in clarifying the residual radiation exposure to atomic bomb survivors at Hiroshima and Nagasaki. The process also involved a re-examination of very early surveys of radioisotope emissions from ground surfaces at Hiroshima and Nagasaki and early reports of health effects. New insights were reported on the potential contribution to residual radiation from neutron-activated radionuclides in the airburst's dust stem and pedestal and in unlofted soil, as well as from fission products and weapon debris from the nuclear cloud. However, disparate views remain concerning the actual residual radiation doses received by the atomic bomb survivors at different distances from the hypocenter. The workshop discussion indicated that measurements made using thermal luminescence and optically stimulated luminescence, like earlier measurements, especially in very thin layers of the samples, could be expanded to detect possible

  8. Determination of dose factors for external gamma radiation in dwellings

    International Nuclear Information System (INIS)

    Maduar, M.F.; Hiromoto, G.

    2000-01-01

    ; and for the distance of the point of calculation to the nearest wall, 10 cm to the center of the room. Selected values left constant, for each parameter, were: thickness, 20 cm; density, 2.35 g.cm -3 , room length, 5 m; and for the position of the calculation point, the center of the room. It was found that the most sensitive parameters are density, that shows a linear dependency to the dose factors; and thickness, where dose factors increase significantly ranging this parameter from 5 to 30 cm, and then tend for limit values for thickness values greater than 30 cm. Ranging the calculation point of the dose inside the room, along the room length, dose has varied no more than 6%. Ranging the room length caused a variation of the dose no greater than 4%. It was also observed that the qualitative behavior of the dose-parameters relations does not change significantly from one radionuclide to another, for all the studied parameters. (author)

  9. Towards a new dose and dose-rate effectiveness factor (DDREF)? Some comments.

    Science.gov (United States)

    Chadwick, K H

    2017-06-26

    The aim of this article is to offer a broader, mechanism-based, analytical tool than that used by (Rühm et al 2016 Ann. ICRP 45 262-79) for the interpretation of cancer induction relationships. The article explains the limitations of this broader analytical tool and the implications of its use in view of the publications by Leuraud et al 2015 (Lancet Haematol. 2 e276-81) and Richardson et al 2015 (Br. Med. J. 351 h5359). The publication by Rühm et al 2016 (Ann. ICRP 45 262-79), which is clearly work in progress, reviews the current status of the dose and dose-rate effectiveness factor (DDREF) as recommended by the ICRP. It also considers the issues which might influence a reassessment of both the value of the DDREF as well as its application in radiological protection. In this article, the problem is approached from a different perspective and starts by commenting on the limited scientific data used by Rühm et al 2016 (Ann. ICRP 45 262-79) to develop their analysis which ultimately leads them to use a linear-quadratic dose effect relationship to fit solid cancer mortality data from the Japanese life span study of atomic bomb survivors. The approach taken here includes more data on the induction of DNA double strand breaks and, using experimental data taken from the literature, directly relates the breaks to cell killing, chromosomal aberrations and somatic mutations. The relationships are expanded to describe the induction of cancer as arising from radiation induced cytological damage coupled to cell killing since the cancer mutated cell has to survive to express its malignant nature. Equations are derived for the induction of cancer after both acute and chronic exposure to sparsely ionising radiation. The equations are fitted to the induction of cancer in mice to illustrate a dose effect relationship over the total dose range. The 'DDREF' derived from the two equations varies with dose and the DDREF concept is called into question. Although the equation for

  10. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  11. Effective dose in abdominal digital radiography: Patient factor

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Sung; Koo, Hyun Jung; Park, Jung Hoon; Cho, Young Chul; Do, Kyung Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of); Yang, Hyung Jin [Dept. of Medical Physics, Korea University, Seoul (Korea, Republic of)

    2017-08-15

    To identify independent patient factors associated with an increased radiation dose, and to evaluate the effect of patient position on the effective dose in abdominal digital radiography. We retrospectively evaluated the effective dose for abdominal digital radiography in 222 patients. The patients were divided into two groups based on the cut-off dose value of 0.311 mSv (the upper third quartile of dose distribution): group A (n = 166) and group B (n = 56). Through logistic regression, independent factors associated with a larger effective dose were identified. The effect of patient position on the effective dose was evaluated using a paired t-test. High body mass index (BMI) (≥ 23 kg/m2), presence of ascites, and spinal metallic instrumentation were significantly associated with a larger effective dose. Multivariate logistic regression analysis revealed that high BMI [odds ratio (OR), 25.201; p < 0.001] and ascites (OR, 25.132; p < 0.001) were significantly associated with a larger effective dose. The effective dose was significantly lesser (22.6%) in the supine position than in the standing position (p < 0.001). High BMI and ascites were independent factors associated with a larger effective dose in abdominal digital radiography. Significant dose reduction in patients with these factors may be achieved by placing the patient in the supine position during abdominal digital radiography.

  12. External dose-rate conversion factors for calculation of dose to the public

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents a tabulation of dose-rate conversion factors for external exposure to photons and electrons emitted by radionuclides in the environment. This report was prepared in conjunction with criteria for limiting dose equivalents to members of the public from operations of the US Department of Energy (DOE). The dose-rate conversion factors are provided for use by the DOE and its contractors in performing calculations of external dose equivalents to members of the public. The dose-rate conversion factors for external exposure to photons and electrons presented in this report are based on a methodology developed at Oak Ridge National Laboratory. However, some adjustments of the previously documented methodology have been made in obtaining the dose-rate conversion factors in this report. 42 refs., 1 fig., 4 tabs.

  13. Factors affecting patient dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Poletti, J.L.

    1985-01-01

    There are two stages in the X-ray image forming process; first the irradiation of the patient to produce the X-ray pattern in space, known as the primary radiological image, and second, the conversion of this pattern into a visible form. This report discusses the first stage and its interrelation with image quality and patient dose

  14. Human and technical factors in the doses reduction and optimization at Cogema/Marcoule

    International Nuclear Information System (INIS)

    Bourgogne, J.L.

    1998-01-01

    In the case of Cogema/Marcoule, the constant decrease of radiation doses is attributed to three factors: technical with a surveillance system and doses optimization, relational with the promotion of confidence in teams of radiation protection services as an acceptation factor of radiation protection techniques and psychological with an evolution of minds towards the ALARA approach. (N.C.)

  15. Conversion Factors for Predicting Unshielded Dose Rates in Shielded Waste

    International Nuclear Information System (INIS)

    Clapham, M.; Seamans Jr, J.V.; Arbon, R.E.

    2009-01-01

    This document describes the methodology developed and used by the Advanced Mixed Waste Treatment Project for determining the activity content and the unshielded surface dose rate for lead lined containers contaminated with transuranic waste. Several methods were investigated: - Direct measurement of the dose rate after removing the shielding. - Use of a MicroShield R derived dose conversion factor, (mRem/hr unshielded )/(mRem/hr shielded ), applied to the measured surface dose rate to estimate the unshielded surface dose rate. - Use of a MicroShield R derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. - Use of an empirically derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. The last approach proved to be the most efficacious by using a combination of nondestructive assay and empirically defined dose rate conversion factors. Empirically derived conversion factors were found to be highly dependent upon the matrix of the waste. Use of conversion factors relied on activity values corrected to address the presence of a lead liner. (authors)

  16. Radiation risk factors and dose limits

    International Nuclear Information System (INIS)

    Barendsen, G.W.

    1979-01-01

    The contents of the ICRP publications 9 (1965) and 26 (1977) are outlined and the research conducted during these years considered. Expressions are derived for the frequency for induction of cancer from the most common irradiations - X rays, gamma rays and electrons. The dose limits advised by the ICRP are discussed and the first two fundamental principles are presented - that no one should be subjected to radiation without useful cause and that in those cases where irradiation is thought necessary, the medical, scientific, social and economic advantages need to be carefully considered with respect to the possible disadvantages. (C.F.)

  17. Development of Landscape Dose Factors for dose assessments in SR-Can

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo; Ekstroem, Per-Anders [Facilia AB, Bromma (Sweden); Kautsky, Ulrik [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)

    2006-08-15

    to the biosphere, it is possible to obtain conservative estimates of the doses to most exposed groups. A summary of the sensitivity analysis and uncertainties of the models is also presented in the report. These preliminary studies show that the effect of the distribution coefficient (K{sub d}) on the maximum values of the dose rates was different in different periods with practically no effect in some periods and pronounced effects in other periods, particularly in periods when ecosystem shifts occur. The maximum LDF values were obtained at different time periods for the different cases included in the sensitivity analyses, with values differing by a factor of 10 or more. The topography, which affects the drainage area, the hydrology, the sedimentation environment and the size of the biosphere objects, is also an important factor. During the sea period, the fraction of accumulation bottoms and the water velocity in the bottom sediments has the largest effect on the retained fraction of the releases. A number of limitations of the previous EDF approach, have been overcome in deriving the LDFs in the study presented here. In particular, the connection of the different ecosystems within the landscape is considered and the fluxes of radionuclides through these interconnected ecosystems are taken into account. This also allows estimation of the significance of simultaneous exposures to several ecosystems and other relevant interactions between ecosystems, such as the use of a lake for irrigation of agricultural lands. A major improvement, as compared to previous approaches, relates to the fact that now temporal changes in the biosphere driven by land rise, ecosystem succession, climate change, etc are explicitly addressed. A further benefit of the dynamic landscape model is that important exposure parameters, such as the size of exposed groups and drainage areas, can be consistently estimated within the landscape model.

  18. Current status on preparation of dose conversion factors based on 1990 ICRP recommendations

    International Nuclear Information System (INIS)

    Yoshizawa, Michio

    1996-01-01

    The current status of arrangement of dose conversion factors for operational quantities are explained on the basis of 1995 ICRP-ICRU recommendations. The dose conversion factors of photon, neutron and electron were recommended by ICRP Publ. 74. It's contents are described. The relation between new dose conversion factors and the laws in connection with protecting radiation are explained. The dose conversion factors of 1 cm-, 3 mm- and 70 μm - dose equivalent which were introduced into the laws connected therewith in Japan are accepted the same values of ICRP Publ. 51 for photon and neutron. I mentioned the points of discussing about new dose conversion factors which are expected to be recommended. The laws have to show the dose conversion factors to be used by calculation and estimation of radiation shield, etc. The limit of energy of ICRU individual dose equivalent for photon is now until 1 MeV, but the value is insufficient and necessary to 10 MeV as same as the ambient dose equivalent in due consideration of atomic energy facilities. JAERI is preparing these dose conversion factors now. (S.Y.)

  19. Ratio of the dose factors of the isotopes of iodine

    International Nuclear Information System (INIS)

    Papadopoulos, D.; Thomas, P.

    1977-12-01

    The ratio of dose factors occurring during inhalation and ingestion to the respective dose factors of I-129 is calculated for the isotopes of I-123 to I-126 and I-129 to I-135. All the dose factors refer to the thyroid as the critical organ. A distinction is made between adults and infants up to 1 year of age. To calculate the ratios only the effective energies and the effective half-lives in the human body and on grass are required. Most of the data have been taken from the literature. The effective energies of I-123 and I-125 have been calculated as examples. (orig.) [de

  20. Estimates of external dose-rate conversion factors and internal dose conversion factors for selected radionuclides released from fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu; Togawa, Orihiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-11-01

    This report provides a tabulation of both external dose-rate conversion factors and internal dose conversion factors using radioactive decay data in the updated Evaluated Nuclear Structure Data File (ENSDF) for selected 26 radionuclides and all their daughter radionuclides of potential importance in safety assessments of fusion facilities. The external dose-rate conversion factors for 21 target organs are tabulated for three exposure modes that are immersion in contaminated air, irradiation at a height of 1 m above a contaminated ground surface and immersion contaminated water. For internal exposure, committed dose equivalents, based on the methodology of ICRP Publication 30, in the same target organs per intake of unit activity are given for the inhalation and ingestion exposure pathways. The data presented here is intended to be generally used for safety assessments of fusion reactors. Comparisons of external effective dose-rate conversion factors and committed effective dose equivalents are made with the previous data from the independent data bases to provide quality assurance on our calculated results. There is generally good agreement among data from the independent data bases. The differences in the values of both effective dose-rate and dose conversion factors appeared are primarily due to differences in calculational methodology, the use of different radioactive decay data, and compilation errors. (author)

  1. Epidemiological issues related to dose reconstruction

    International Nuclear Information System (INIS)

    Shore, R.E.

    1996-01-01

    When a dose reconstruction is performed around some nuclear site, a decision has to be made as to whether an epidemiologic study should be performed there and, if so, what form the study should take. The goal of this paper is to provide an overview of epidemiologic and biostatistical issues that help determine whether an epidemiologic study around a nuclear facility is worthwhile doing from a scientific standpoint. We are all aware that public health and sociopolitical concerns often assume considerable importance in these decisions, but they will not be considered here. 27 refs., 2 tabs

  2. Mammography dose in relation to body mass index, race, and menopausal status

    Energy Technology Data Exchange (ETDEWEB)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G

    2002-07-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  3. Mammography dose in relation to body mass index, race, and menopausal status

    International Nuclear Information System (INIS)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G.

    2002-01-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  4. Dose modification factors in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Allen, B.J. (Australian Nuclear Science and Technology Organization (ANSTO), Menai (Australia))

    1993-01-01

    The effective treatment depth and therapeutic ratio in boron neutron capture therapy (BNCT) depend on a number of macroscopic dose factors such as boron concentrations in the tumor, normal tissue and blood. However, the role of various microscopic dose modification factors can be of critical importance in the evaluation of normal tissue tolerance levels. An understanding of these factors is valuable in designing BNCT experiments and the selection of appropriate boron compounds. These factors are defined in this paper and applied to the case of brain tumors with particular attention to capillary endothelial cells and oligodendrocytes. (orig.).

  5. Factors affecting calculations of dose resulting from a tritium release into the atmosphere

    International Nuclear Information System (INIS)

    Otaduy, P.; Easterly, C.E.; Booth, R.S.; Jacobs, D.G.

    1976-01-01

    Tritium releases in the form of HT represent a lower hazard to man than releases as HTO. However, during movement in the environment, HT is converted into HTO. The effects of the conversion rate on calcultions of dose are described, and a general method is presented for determining the dose from tritium for various conversion rates and relative HTO/HT risk factors

  6. Age-dependent dose factors and dose limits of annual radioactivity uptake with unsealed radioactive substances by occupationally exposed persons

    International Nuclear Information System (INIS)

    Kaul, A.; Nosske, D; Elsasser, U; Roedler, H.D.; Henrichs, K.

    1986-01-01

    The dose factors have been calculated on the basis of the ICRP models for dosimetric and metabolistic assessment, and are laid open in accordance with Annex XI ( to sec. 45 sub-section (2)) of the amended version of the Radiation Protection Ordinance. The contribution in hand explains the scientific fundamentals and results of the calculations of dose factors relating to inhalation and ingestion of unsealed radioactive substances by adult reference man, and age-dependent factors calculated for children and adolescents. Further, annual limits of uptake by occupationally exposed persons, as calculated on the basis of primary dose limits pursunant to the draft amendment presented by the Federal Interior Minister, are compared with relevant data given by the ICRP and EC institutions. (orig./DG) [de

  7. Biosphere dose conversion Factor Importance and Sensitivity Analysis

    International Nuclear Information System (INIS)

    M. Wasiolek

    2004-01-01

    This report presents importance and sensitivity analysis for the environmental radiation model for Yucca Mountain, Nevada (ERMYN). ERMYN is a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis concerns the output of the model, biosphere dose conversion factors (BDCFs) for the groundwater, and the volcanic ash exposure scenarios. It identifies important processes and parameters that influence the BDCF values and distributions, enhances understanding of the relative importance of the physical and environmental processes on the outcome of the biosphere model, includes a detailed pathway analysis for key radionuclides, and evaluates the appropriateness of selected parameter values that are not site-specific or have large uncertainty

  8. The relative biological effectiveness of out-of-field dose

    International Nuclear Information System (INIS)

    Balderson, Michael; Koger, Brandon; Kirkby, Charles

    2016-01-01

    Purpose: using simulations and models derived from existing literature, this work investigates relative biological effectiveness (RBE) for out-of-field radiation and attempts to quantify the relative magnitudes of different contributing phenomena (spectral, bystander, and low dose hypersensitivity effects). Specific attention is paid to external beam radiotherapy treatments for prostate cancer. Materials and methods: using different biological models that account for spectral, bystander, and low dose hypersensitivity effects, the RBE was calculated for different points moving radially out from isocentre for a typical single arc VMAT prostate case. The RBE was found by taking the ratio of the equivalent dose with the physical dose. Equivalent doses were calculated by determining what physical dose would be necessary to produce the same overall biological effect as that predicted using the different biological models. Results: spectral effects changed the RBE out-of-field less than 2%, whereas response models incorporating low dose hypersensitivity and bystander effects resulted in a much more profound change of the RBE for out-of-field doses. The bystander effect had the largest RBE for points located just outside the edge of the primary radiation beam in the cranial caudal (z-direction) compared to low dose hypersensitivity and spectral effects. In the coplanar direction, bystander effect played the largest role in enhancing the RBE for points up to 8.75 cm from isocentre. Conclusions: spectral, bystander, and low dose hypersensitivity effects can all increase the RBE for out-of-field radiation doses. In most cases, bystander effects seem to play the largest role followed by low dose hypersensitivity. Spectral effects were unlikely to be of any clinical significance. Bystander, low dose hypersensitivity, and spectral effect increased the RBE much more in the cranial caudal direction (z-direction) compared with the coplanar directions. (paper)

  9. A systematic study on factors affecting patient dose, (1)

    International Nuclear Information System (INIS)

    Otsuka, Akiyoshi; Higashida, Yoshiharu; Utsumi, Hiromoto; Ota, Masaji; Nakanishi, Takashi

    1979-01-01

    In the study of possible reduction in irradiation dose to patients during medical treatments, the following two methods can be considered: (1) To obtain absorbed doses for each part of a body in diagnostic X-ray examinations. (2) To obtain data on factors such as the tube voltage which may affect patient dose. There are a number of reports both at home and abroad concerning the above (1), but very few reports are available concerning the above (2). Moreover, most of them are on fragmentary aspects of each factor and no systematic reports have been made. For this reason, we have taken up, as factors affecting the patient dose, the field size, the tube voltage, and by checking them again, we wanted to obtain some systematic data. Our aim has been fully attained by conducting an experiment. In the ICRP's Publ. 26 issued last year, the idea of the critical organ which had not been fully elucidated in the Publ. 9 was abandoned. As a result, assessment of the irradiation doses has become more rational and the total risk for an individual was obtained. In Japan, the idea proposed in the Publ. 9 is adopted. Therefore, in this paper, we will raise some questions regarding the assessment of the irradiation doses, pointing out at the same time the rationality of the idea put forward in Publ. 26. (author)

  10. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  11. Volume correction factor in time dose relationships in brachytherapy

    International Nuclear Information System (INIS)

    Supe, S.J.; Sasane, J.B.

    1987-01-01

    Paterson's clinical data about the maximum tolerance doses for various volumes of interstitial implants with Ra-226 delivered in seven days was made use of in deriving volume correction factors for TDF and CRE concepts respectively for brachytherapy. The derived volume correction factors for TDF and for CRE differ fromthe one assumed for CRE by Kirk et al. and implied for TDF by Goitein. A normalising volume of 70 cc has been suggested for both CRE and TDF concepts for brachytherapy. A table showing the volume corrected TDF is presented for various volumes and dose rates for continuous irradiation. The use of this table is illustrated with examples. (orig.) [de

  12. Internal dose conversion factors for calculation of dose to the public

    International Nuclear Information System (INIS)

    1988-07-01

    This publication contains 50-year committed dose equivalent factors, in tabular form. The document is intended to be used as the primary reference by the US Department of Energy (DOE) and its contractors for calculating radiation dose equivalents for members of the public, resulting from ingestion or inhalation of radioactive materials. Its application is intended specifically for such materials released to the environment during routine DOE operations, except in those instances where compliance with 40 CFR 61 (National Emission Standards for Hazardous Air Pollutants) requires otherwise. However, the calculated values may be equally applicable to unusual releases or to occupational exposures. The use of these committed dose equivalent tables should ensure that doses to members of the public from internal exposures are calculated in a consistent manner at all DOE facilities

  13. Dose reduction factors from a radioactive cloud for large buildings

    International Nuclear Information System (INIS)

    Grand, J. le; Roux, Y.

    1986-01-01

    A set of complex and accurate computer codes has been established to determine the transport of photons emitted from a radioactive cloud through various media. The geometrical and physical description of large buildings with various numbers of floors and rooms can be done by the user. The codes can calculate, in any room or apartment, the characteristics of the photon fields (photon flux, energy flux and distribution, direction distribution) and whole-body absorbed dose rates in a phantom standing or lying on the floor. The dose reduction factor is then the quotient of the mean absorbed dose rate in the apartment to the absorbed dose rate in the phantom standing on the ground outdoors. Applications to several modern multistorey buildings are presented. The results show the influence of various parameters such as density and composition of building materials, the fraction of the external building surface containing apertures and initial photon energy. (author)

  14. Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose

    Science.gov (United States)

    Rabi, R.; Oufni, L.

    2018-04-01

    The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.

  15. Organ-specific external dose coefficients and protective apron transmission factors for historical dose reconstruction for medical personnel.

    Science.gov (United States)

    Simon, Steven L

    2011-07-01

    While radiation absorbed dose (Gy) to the skin or other organs is sometimes estimated for patients from diagnostic radiologic examinations or therapeutic procedures, rarely is occupationally-received radiation absorbed dose to individual organs/tissues estimated for medical personnel; e.g., radiologic technologists or radiologists. Generally, for medical personnel, equivalent or effective radiation doses are estimated for compliance purposes. In the very few cases when organ doses to medical personnel are reconstructed, the data is usually for the purpose of epidemiologic studies; e.g., a study of historical doses and risks to a cohort of about 110,000 radiologic technologists presently underway at the U.S. National Cancer Institute. While ICRP and ICRU have published organ-specific external dose conversion coefficients (DCCs) (i.e., absorbed dose to organs and tissues per unit air kerma and dose equivalent per unit air kerma), those factors have been published primarily for mono-energetic photons at selected energies. This presents two related problems for historical dose reconstruction, both of which are addressed here. It is necessary to derive conversion factor values for (1) continuous distributions of energy typical of diagnostic medical x-rays (bremsstrahlung radiation), and (2) energies of particular radioisotopes used in medical procedures, neither of which are presented in published tables. For derivation of DCCs for bremsstrahlung radiation, combinations of x-ray tube potentials and filtrations were derived for different time periods based on a review of relevant literature. Three peak tube potentials (70 kV, 80 kV, and 90 kV) with four different amounts of beam filtration were determined to be applicable for historic dose reconstruction. The probabilities of these machine settings were assigned to each of the four time periods (earlier than 1949, 1949-1954, 1955-1968, and after 1968). Continuous functions were fit to each set of discrete values of the

  16. Factors influencing botulinum toxin dose instability in spasmodic dysphonia patients.

    Science.gov (United States)

    Rosow, David E; Pechman, Amanda; Saint-Victor, Sandra; Lo, Kaming; Lundy, Donna S; Casiano, Roy R

    2015-05-01

    Many patients with spasmodic dysphonia (SD) see consistent effects from botulinum toxin (BTX) injections of the same dose, whereas others require dosage changes over time. We sought to determine whether demographics (age and gender) or environmental factors (smoking) affect the long-term stability of BTX dosing in these patients. Retrospective review. Charts of all patients undergoing BTX injection for adductor SD were reviewed. Dosage change, defined as whether there was any difference in total dosage used between two beneficial injections, was used as a measure of dosing stability. Beneficial injections were indicated by a voice rating score of at least three of four and any non-zero duration of improved voice. Logistic regression analysis was performed to determine whether age, gender, smoking status, or duration of treatment correlated with odds of having a dosage change. A total of 211 patients were ultimately included. Age, gender, and smoking status were all found to have no correlative effect on dosing stability. The only factor that was predictive of dose stability was the number of previous beneficial injections, as every additional injection led to decreased odds of a change in dosage for the next injection (odds ratio=0.964; 95% confidence interval=0.947-0.981). Dosage of BTX injections for long-term treatment of SD has a significant propensity to remain stable over time. Factors such as age, gender, and smoking status do not appear to influence the dosage stability. These findings should allow for better patient counseling regarding expectations for their long-term treatment. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  17. Radiation dose to relations of patients treated with 131I

    International Nuclear Information System (INIS)

    Pant, G.S.; Sharma, S.K.; Bal, C.S.; Rakesh Kumar; Rath, G.K.

    2003-01-01

    Due to its efficacy and simplicity, radioiodine treatment of thyrotoxicosis and differentiated thyroid cancer (DTC) has become extremely popular. A large number of such patients are getting benefit with this treatment modality. Though the radiation dose to the relations of these patients, who may be in close proximity for some time after treatment have been mentioned as within safe limits but we do have sufficient data of our own in India. The life style and social conditions in India are very different than in the developed world. We have been measuring external dose in relations/attendants of these patients who have enough chance to come in close contacts with patients during and after their radioiodine treatment. The TL discs of CaSO 4 (Renentech Laboratories) were exposed to graded doses of gamma photons from 131 I for establishing a dose response relationship. The annealed discs from a given lot were measured for background counts and issued to the relations of patients who have maximum chance of being in proximity with the patient for 2 weeks. The TLDs were collected after a use of 2 weeks for dose estimation. We have so far studied 60 families with a total of 71 attendants. The external doses in all the persons attending the patients at home are well within safe prescribed limits. However, due to varied social and practical circumstances 5 persons exceeded 1 mSv dose. This is possibly due to travelling long distance by train immediately after discharge from the hospital when the accompanying person remains in close proximity throughout the journey. There are situations for non-ambulatory patients, when the attendants have to attend them for relatively longer period. (author)

  18. Dose and effect relationship of radiation induced cancer and its influencing factors in experimental animals, 1

    International Nuclear Information System (INIS)

    Sasaki, Shunsaku; Sato, Fumiaki; Eto, Hideo

    1975-01-01

    The data of risk evaluation of external irradiation were integrated with animal experiments from the aspects of qualitative generalizations of characteristics of radiation induced tumors. Studies covered competition of cause of death, figure of dose-to-effect relationship, characteristics of low dose rate of irradiation, relative biological effectiveness (RBE) of high LET radiation, effects of feactionated irradiation, complex actions with chemical substances, effects of protectional medium, differences of radiosensitivity by species and strains, and age dependency of sensitivities. Competition of cause of death by time length of latent period and degree of malignancy of the disease. Discussion on competition of death suggested the following idea: 1) incidence of tumor induction in the individual level did not correspond to transformation in the cellular level, and 2) relative incidence of tumor induction after a certain dose of whole body irradiation did not indicate the relative sensitivity of each tissue, for the relationship between tumor incidence and exposure dose was not a linear relationship. The dose-to-effect relationship of tumor induction was decided by following factors: i) sensitivity on transformation of cells, ii) sensitivity on the death of potential tumor cells, and iii) competition of the cause of death. Tumor induction by low dose rate irradiation was also studied by comparing qualitative and quantitative differences between high dose rate single irradiation and a series of low dose rate irradiation. (Serizawa, K.)

  19. Effect of edema, relative biological effectiveness, and dose heterogeneity on prostate brachytherapy

    International Nuclear Information System (INIS)

    Wang, Jian Z.; Mayr, Nina A.; Nag, Subir; Montebello, Joseph; Gupta, Nilendu; Samsami, Nina; Kanellitsas, Christos

    2006-01-01

    Many factors influence response in low-dose-rate (LDR) brachytherapy of prostate cancer. Among them, edema, relative biological effectiveness (RBE), and dose heterogeneity have not been fully modeled previously. In this work, the generalized linear-quadratic (LQ) model, extended to account for the effects of edema, RBE, and dose heterogeneity, was used to assess these factors and their combination effect. Published clinical data have shown that prostate edema after seed implant has a magnitude (ratio of post- to preimplant volume) of 1.3-2.0 and resolves exponentially with a half-life of 4-25 days over the duration of the implant dose delivery. Based on these parameters and a representative dose-volume histogram (DVH), we investigated the influence of edema on the implant dose distribution. The LQ parameters (α=0.15 Gy -1 and α/β=3.1 Gy) determined in earlier studies were used to calculate the equivalent uniform dose in 2 Gy fractions (EUD 2 ) with respect to three effects: edema, RBE, and dose heterogeneity for 125 I and 103 Pd implants. The EUD 2 analysis shows a negative effect of edema and dose heterogeneity on tumor cell killing because the prostate edema degrades the dose coverage to tumor target. For the representative DVH, the V 100 (volume covered by 100% of prescription dose) decreases from 93% to 91% and 86%, and the D 90 (dose covering 90% of target volume) decrease from 107% to 102% and 94% of prescription dose for 125 I and 103 Pd implants, respectively. Conversely, the RBE effect of LDR brachytherapy [versus external-beam radiotherapy (EBRT) and high-dose-rate (HDR) brachytherapy] enhances dose effect on tumor cell kill. In order to balance the negative effects of edema and dose heterogeneity, the RBE of prostate brachytherapy was determined to be approximately 1.2-1.4 for 125 I and 1.3-1.6 for 103 Pd implants. These RBE values are consistent with the RBE data published in the literature. These results may explain why in earlier modeling studies

  20. Dose-response relation between physical activity and sick leave

    NARCIS (Netherlands)

    Proper, K.I.; Heuvel, S.G. van den; Vroome, E.M. de; Hildebrandt, V.H.; Beek, A.J. van der

    2006-01-01

    Objective: To investigate the dose-response relation between moderate and vigorous physical activity and sick leave in a working population. Methods: Data were used from three large Dutch databases: two continuous, cross sectional surveys among a representative sample of the Dutch population and one

  1. SU-E-T-577: Obliquity Factor and Surface Dose in Proton Beam Therapy

    International Nuclear Information System (INIS)

    Das, I; Andersen, A; Coutinho, L

    2015-01-01

    Purpose: The advantage of lower skin dose in proton beam may be diminished creating radiation related sequalae usually seen with photon and electron beams. This study evaluates the surface dose as a complex function of beam parameters but more importantly the effect of beam angle. Methods: Surface dose in proton beam depends on the beam energy, source to surface distance, the air gap between snout and surface, field size, material thickness in front of surface, atomic number of the medium, beam angle and type of nozzle (ie double scattering, (DS), uniform scanning (US) or pencil beam scanning (PBS). Obliquity factor (OF) is defined as ratio of surface dose in 0° to beam angle Θ. Measurements were made in water phantom at various beam angles using very small microdiamond that has shown favorable beam characteristics for high, medium and low proton energy. Depth dose measurements were performed in the central axis of the beam in each respective gantry angle. Results: It is observed that surface dose is energy dependent but more predominantly on the SOBP. It is found that as SSD increases, surface dose decreases. In general, SSD, and air gap has limited impact in clinical proton range. High energy has higher surface dose and so the beam angle. The OF rises with beam angle. Compared to OF of 1.0 at 0° beam angle, the value is 1.5, 1.6, 1,7 for small, medium and large range respectively for 60 degree angle. Conclusion: It is advised that just like range and SOBP, surface dose should be clearly understood and a method to reduce the surface dose should be employed. Obliquity factor is a critical parameter that should be accounted in proton beam therapy and a perpendicular beam should be used to reduce surface dose

  2. Alternatives to dose, quality factor and dose equivalent for low level irradiation

    International Nuclear Information System (INIS)

    Sondhaus, C.A.; Bond, V.P.; Feinendegen, L.E.

    1988-01-01

    Randomly occurring energy deposition events produced by low levels of ionizing radiation interacting with tissue deliver variable amounts of energy to the sensitive target volumes within a small fraction of the cell population. A model is described in which an experimentally derived function relating event size to cell response probability operates mathematically on the microdosimetric event size distribution characterizing a given irradiation and thus determines the total fractional number of responding cells; this fraction measures the effectiveness of the given radiation. Normalizing to equal numbers of events produced by different radiations and applying this cell response or hit size effectiveness function (HSEF) should define radiation quality, or relative effectiveness, on a more nearly absolute basis than do the absorbed dose and dose evaluation, which are confounded when applied to low level irradiations. Examples using both calculation and experimental data are presented. 15 refs., 18 figs

  3. The relative importance of ingestion for multiple pathway dose assessments

    International Nuclear Information System (INIS)

    Wicker, W.; Grogan, H.; Bergstroem, U.; Hoffman, O.

    1991-01-01

    The general purpose of this report is to examine the relative importance of ingestion pathways, and particularly food chain transport in overall dose assessment. The importance of ingestion pathways is examined for various release scenarios and radionuclides because the findings are expected to differ with circumstances. The degree to which contaminated food products contribute to the total dose will affect the importance of accuracy and uncertainty of food chain model predictions, which is the main thrust of the Biospheric Model Validation Study (BIOMOVS). This analysis requires that all modes of radiation exposure be examined, including inhalation, external exposure, and the various ingestion pathways. (2 figs., 2 tabs.)

  4. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  5. Risk of solid cancer in low dose-rate radiation epidemiological studies and the dose-rate effectiveness factor.

    Science.gov (United States)

    Shore, Roy; Walsh, Linda; Azizova, Tamara; Rühm, Werner

    2017-10-01

    Estimated radiation risks used for radiation protection purposes have been based primarily on the Life Span Study (LSS) of atomic bomb survivors who received brief exposures at high dose rates, many with high doses. Information is needed regarding radiation risks from low dose-rate (LDR) exposures to low linear-energy-transfer (low-LET) radiation. We conducted a meta-analysis of LDR epidemiologic studies that provide dose-response estimates of total solid cancer risk in adulthood in comparison to corresponding LSS risks, in order to estimate a dose rate effectiveness factor (DREF). We identified 22 LDR studies with dose-response risk estimates for solid cancer after minimizing information overlap. For each study, a parallel risk estimate was derived from the LSS risk model using matching values for sex, mean ages at first exposure and attained age, targeted cancer types, and accounting for type of dosimetric assessment. For each LDR study, a ratio of the excess relative risk per Gy (ERR Gy -1 ) to the matching LSS ERR risk estimate (LDR/LSS) was calculated, and a meta-analysis of the risk ratios was conducted. The reciprocal of the resultant risk ratio provided an estimate of the DREF. The meta-analysis showed a LDR/LSS risk ratio of 0.36 (95% confidence interval [CI] 0.14, 0.57) for the 19 studies of solid cancer mortality and 0.33 (95% CI 0.13, 0.54) when three cohorts with only incidence data also were added, implying a DREF with values around 3, but statistically compatible with 2. However, the analyses were highly dominated by the Mayak worker study. When the Mayak study was excluded the LDR/LSS risk ratios increased: 1.12 (95% CI 0.40, 1.84) for mortality and 0.54 (95% CI 0.09, 0.99) for mortality + incidence, implying a lower DREF in the range of 1-2. Meta-analyses that included only cohorts in which the mean dose was LDR data provide direct evidence regarding risk from exposures at low dose rates as an important complement to the LSS risk estimates used

  6. Factors affecting radiation doses from dedicated rail transport of spent reactor fuel

    International Nuclear Information System (INIS)

    Martin, J.E.

    1988-01-01

    This paper reports there are two exposure control concerns associated with the shipment of spent reactor fuel in dedicated trains -- compliance with transportation regulations for maximum allowable radiation levels, and minimizing the dose received by the general public. This article examines the methods used to calculate the dose equivalent rates alongside stationary (transport regulations) and moving trains (public exposure) of various lengths. The factors examined include the source term, the effect of overlapping radiation fields, the speed of the train, and the location of the population relative to the train. Trains made up of series of cars that individually meet transport regulations can, as a whole, exceed transport vehicle dose equivalent rate limits by up to 23% due to overlapping radiation fields. For moving trains and the worst case analyzed -- a person located 20 feet from the tracks and a train speed of 5 mph --- 141 rail cars would have to pass by to deliver a dose equivalent of 1 mrem

  7. Relation Between Demographic Factors And Hospitalization In ...

    African Journals Online (AJOL)

    Relation Between Demographic Factors And Hospitalization In Patients With Gastrointestinal Disorders, Using Quantail Regression Analysis. ... East African Journal of Public Health ... Objective: The aim of this study is to investigate relation between demographic factors and hospitalization in gastrointestinal disorders.

  8. Thyroid Radiation Dose and Other Risk Factors of Thyroid Carcinoma Following Childhood Cancer.

    Science.gov (United States)

    de Vathaire, Florent; Haddy, Nadia; Allodji, Rodrigue S; Hawkins, Mike; Guibout, Catherine; El-Fayech, Chiraz; Teinturier, Cécile; Oberlin, Odile; Pacquement, Hélène; Diop, Fara; Kalhouche, Amar; Benadjaoud, Mohamedamine; Winter, David; Jackson, Angela; Bezin Mai-Quynh, Giao; Benabdennebi, Aymen; Llanas, Damien; Veres, Cristina; Munzer, Martine; Nguyen, Tan Dat; Bondiau, Pierre-Yves; Berchery, Delphine; Laprie, Anne; Deutsch, Eric; Lefkopoulos, Dimitri; Schlumberger, Martin; Diallo, Ibrahima; Rubino, Carole

    2015-11-01

    Thyroid carcinoma is a frequent complication of childhood cancer radiotherapy. The dose response to thyroid radiation dose is now well established, but the potential modifier effect of other factors requires additional investigation. This study aimed to investigate the role of potential modifiers of the dose response. We followed a cohort of 4338 5-year survivors of solid childhood cancer treated before 1986 over an average of 27 years. The dose received by the thyroid gland and some other anatomical sites during radiotherapy was estimated after reconstruction of the actual conditions in which irradiation was delivered. Fifty-five patients developed thyroid carcinoma. The risk of thyroid carcinoma increased with a radiation dose to the thyroid of up to two tenths of Gy, then leveled off for higher doses. When taking into account the thyroid radiation dose, a surgical or radiological splenectomy (>20 Gy to the spleen) increased thyroid cancer risk (relative risk [RR] = 2.3; 95% confidence interval [CI], 1.3-4.0), high radiation doses (>5 Gy) to pituitary gland lowered this risk (RR = 0.2; 95% CI, 0.1-0.6). Patients who received nitrosourea chemotherapy had a 6.6-fold (95% CI, 2.5-15.7) higher risk than those who did not. The excess RR per Gy of radiation to the thyroid was 4.7 (95% CI, 1.7-22.6). It was 7.6 (95% CI, 1.6-33.3) if body mass index at time of interview was equal or higher than 25 kg/m(2), and 4.1 (95% CI, 0.9-17.7) if not (P for interaction = .1). Predicting thyroid cancer risk following childhood cancer radiation therapy probably requires the assessment of more than just the radiation dose to the thyroid. Chemotherapy, splenectomy, radiation dose to pituitary gland, and obesity also play a role.

  9. Calculated dose factors for the radiosensitive tissues in bone irradiated by surface-deposited radionuclides

    International Nuclear Information System (INIS)

    Spiers, F.W.; Whitwell, J.R.; Beddoe, A.H.

    1978-01-01

    The method of calculating dose factors for the haemopoietic marrow and endosteal tissues in human trabecular bone, used by Whitwell and Spiers for volume-seeking radionuclides, has been developed for the case of radionuclides which are deposited as very thin layers on bone surfaces. The Monte Carlo method is again used, but modifications to the computer program are made to allow for a surface rather than a volume source of particle emission. The principal change is the introduction of a surface-orientation factor which is shown to have a value of approximately 2, varying slightly with bone structure. Results are given for β-emitting radionuclides ranging from 171 Tm(anti Esub(β) = 0.025 MeV) to 90 Y(anti Esub(β) = 0.93 MeV), and also for the α-emitter 239 Pu. It is shown that where the particle ranges are short compared with the dimensions of the bone structures the dose factors for the surface seekers are much greater than those for the volume seekers. For long range particles the dose factors for surface- and volume-seeking radionuclides converge. Comparisons are given relating the dose factors calculated in this paper on the basis of measured bone structures to those of other workers based on single plane geometry. (author)

  10. Comprehensive analysis of a medication dosing error related to CPOE.

    Science.gov (United States)

    Horsky, Jan; Kuperman, Gilad J; Patel, Vimla L

    2005-01-01

    This case study of a serious medication error demonstrates the necessity of a comprehensive methodology for the analysis of failures in interaction between humans and information systems. The authors used a novel approach to analyze a dosing error related to computer-based ordering of potassium chloride (KCl). The method included a chronological reconstruction of events and their interdependencies from provider order entry usage logs, semistructured interviews with involved clinicians, and interface usability inspection of the ordering system. Information collected from all sources was compared and evaluated to understand how the error evolved and propagated through the system. In this case, the error was the product of faults in interaction among human and system agents that methods limited in scope to their distinct analytical domains would not identify. The authors characterized errors in several converging aspects of the drug ordering process: confusing on-screen laboratory results review, system usability difficulties, user training problems, and suboptimal clinical system safeguards that all contributed to a serious dosing error. The results of the authors' analysis were used to formulate specific recommendations for interface layout and functionality modifications, suggest new user alerts, propose changes to user training, and address error-prone steps of the KCl ordering process to reduce the risk of future medication dosing errors.

  11. Radiation dose to the thyroid due to incorporation of iodine isotopes: Age dependence and reliability of dose factors

    International Nuclear Information System (INIS)

    Henrichs, K.; Mueller-Brunecker, G.; Paretzke, H.G.

    1983-08-01

    This is the first time that dose factors are published in the literature, together with an assessment of their reliability with regard to the quantification of the dose received by the population in the Federal Republic of Germany due to incorporation if iodine isotopes, taking into account the given age distribution among the population. The calculation of dose factors is based on the latest dosimetric and metabolic models issued by the ICRP (ICRP-30), and the impact of the various parameters and their variability on the accuracy of dose factor determination is assessed. The procedure followed to calculate the dose due to incorporation on the basis of metabolic models (ICRP 1978 and ICRP 1979) is explained. The main data (such as half life, mean frequency per decay, mean energy in keV) are given for I-123, I-125, I-129, I-131, I-132, I-133, I-134, and I-135 (ICRP-30) and listed in tables. (orig./HP) [de

  12. The time factor in dose-effect relationships

    International Nuclear Information System (INIS)

    Jones, H.B.; Grendon, A.; White, M.R.; California Univ., Berkeley

    1976-01-01

    The assumption that carcinogenic risk is proportional to dose fails to consider that probable time of actual cancer incidence. The time lag between exposure and carcinogenic effect for radiation and chemical agents varies as Dosesup(-1/n), with napproximately3. A model is offered explaining that concentration of initially altered cells depends on dose, whereas their chance for development into tumours on their proximity, which varies as Dsup(-1/3). Because of biological variability, n has a range of values. The model implies that tumours resulting from a single exposure should be closely distributed in time, producing a pulse of cases and subsequently being essentially without effect. Testing of the Dsup(-1/3) rule was extended and its model, by further refinement of methods, applied to radiogenic leukaemia risk and to the effect of urethan in inducing lung tumours in mice with and without radiation exposure as a possible cocarcinogen. Radiation did not affect the tumour yield from urethan in mice. Radiogenic leukaemia and lung tumours induced by urethan both occur in proportion to exposure, but the time of their occurrence is limited to a short interval in relation to life span. Similarly, in murine or in human radiogenic leukaemia, leukaemia risk occurs in proportion to exposure, but the time of occurrences is limited to a short interval in relation to life span. In both sets of observations, as well as in other test systems of carcinogenesis, the peak of occurrence or the mean latent period is roughly inversely related to Dsup(-1/3). Applied to lung tumours and leukaemia, the spread of cases about the peak incidence was found to be typically less than a fifth of the life span. Exposure risks do not continue to act over life span. Neoplastic disease risk from carcinogens levels too low to be tested experimentally, theoretically usually lies beyond the life span. The social and economic consequences of a theoretically calculated number of deaths due to those

  13. Factors affecting relative pitch perception

    OpenAIRE

    McClaskey, Carolyn Marie

    2016-01-01

    Sounds that evoke a sense of pitch are ubiquitous in our environment and important for speech, music, and auditory scene analysis. The frequencies of these sounds rarely remain constant, however, and the direction and extent of pitch change is often more important than the exact pitches themselves. This dissertation examines the mechanisms underlying how we perceive relative pitch distance, focusing on two types of stimuli: continuous pitch changes and discrete pitch changes. In a series of e...

  14. Choosing an alpha radiation weighting factor for doses to non-human biota

    International Nuclear Information System (INIS)

    Chambers, Douglas B.; Osborne, Richard V.; Garva, Amy L.

    2006-01-01

    The risk to non-human biota from exposure to ionizing radiation is of current international interest. In calculating radiation doses to humans, it is common to multiply the absorbed dose by a factor to account for the relative biological effectiveness (RBE) of the radiation type. However, there is no international consensus on the appropriate value of such a factor for weighting doses to non-human biota. This paper summarizes our review of the literature on experimentally determined RBEs for internally deposited alpha-emitting radionuclides. The relevancy of each experimental result in selecting a radiation weighting factor for doses from alpha particles in biota was judged on the basis of criteria established a priori. We recommend a nominal alpha radiation weighting factor of 5 for population-relevant deterministic and stochastic endpoints, but to reflect the limitations in the experimental data, uncertainty ranges of 1-10 and 1-20 were selected for population-relevant deterministic and stochastic endpoints, respectively

  15. An algorithm for intelligent sorting of CT-related dose parameters

    Science.gov (United States)

    Cook, Tessa S.; Zimmerman, Stefan L.; Steingal, Scott; Boonn, William W.; Kim, Woojin

    2011-03-01

    Imaging centers nationwide are seeking innovative means to record and monitor CT-related radiation dose in light of multiple instances of patient over-exposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose-length product (DLP)-an indirect estimate of radiation dose-requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, Arterial could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired, and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  16. An algorithm for intelligent sorting of CT-related dose parameters.

    Science.gov (United States)

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Boonn, William W; Kim, Woojin

    2012-02-01

    Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)--an indirect estimate of radiation dose--requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, "arterial" could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  17. Radiation-related operator's dose distribution according to LLD(recording level)

    International Nuclear Information System (INIS)

    Park, Jae Duck

    2008-01-01

    Recently, the area of radiation usage is being enlarged by the industry's advancement over the world. And, the usage of radiation generator and radioisotope is increasing every year. So, they are researching actively how to protect operators from the radiation that causes direct or indirect harmfulness to radiation-related operators of the related institutions. Therefore, in case of operator's dose, not only the main dosimeter's correctness but also the reasonal evaluation to the read values becomes the important factor. From this view, LLD's application to the read dose value is being embossed more importantly than any other thing. So, this study tried to find out what change was generated in the personal dose and the group dose when LLD was applied based on the internal real operator's read value, for 3 years, 2005 - 2007, and find out the personal dose change after dividing them into the exposure group and the supervising group based on the common people's personal dose (1 mSv/y)

  18. Genetic Factors Affecting Susceptibility to Low Dose & Low Dose-Rate Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, Joel

    2014-04-18

    Our laboratory has, among other things, developed and used the gamma H2AX focus assay and other chromosomal and cell killing assays to show that differences in this DNA double strand break (dsb) related response can be clearly and distinctly demonstrated for cells which are mildly hyper-radiosensitive such as those associated with A-T heterozygosity. We have found this level of mild hypersensitivity for cells from some 20 to 30 % of apparently normal individuals and from apparently normal parents of Retinoblastoma patients. We found significant differences in gene expression in somatic cells from unaffected parents of Rb patients as compared with normal controls, suggesting that these parents may harbor some as yet unidentified genetic abnormality. In other experiments we sought to determine the extent of differences in normal human cellular reaponses to radiation depending on their irradiation in 2D monolayer vs 3D organized acinar growth conditions. We exmined cell reproductive death, chromosomal aberration induction, and the levels of γ-H2AX foci in cells after single acute gamma-ray doses and immediately after 20 hours of irradiation at a dose rate of 0.0017 Gy/min. We found no significant differences in the dose-responses of these cells under the 2D or 3D growth conditions. While this does not mean such differences cannot occur in other situations, it does mean that they do not generally or necessarily occur. In another series of studies in collaboration with Dr Chuan Li, with supprt from this current grant. We reported a role for apoptotic cell death in promoting wound healing and tissue regeneration in mice. Apoptotic cells released growth signals that stimulated the proliferation of progenitor or stem cells. In yet another collaboration with Dr, B. Chen with funds from this grant, the relative radiosensitivity to cell killing as well as chromosomal instability of 13 DNA-PKcs site-directed mutant cell lines (defective at phosphorylation sites or kinase

  19. Job-related mortality risks of Hanford workers and their relation to cancer effects of measured doses of external radiation

    International Nuclear Information System (INIS)

    Kneale, G.W.; Mancuso, T.F.; Stewart, A.M.

    1983-01-01

    If we exclude all persons who were classified as clerical workers we find that over 40% of the Hanford workers had either professional or technical qualifications (professional workers). The ratio of professional to manual workers was equally high for safe and dangerous occupations but during the period 1944-77 professional workers who were doing the most dangerous work had too many deaths by comparison with other persons with similar qualifications, and manual workers doing equally dangerous work had too few deaths by comparison with other manual workers. In practice, this means that in any analysis of dose-related cancer risks of Hanford workers it is essential to control for job-related mortality risks as well as all the usual factors such as sex, dates of birth and hire and duration of employment. The results of including all these factors in a cohort analysis of Hanford data by the method of regression models in life tables are described and also the reasons why it was concluded that the risk per unit dose is increased at low dose levels (i.e. the dose-response curve is curvilinear downwards). (author)

  20. Total Ambient Dose Equivalent Buildup Factor Determination for Nbs04 Concrete.

    Science.gov (United States)

    Duckic, Paulina; Hayes, Robert B

    2018-06-01

    Buildup factors are dimensionless multiplicative factors required by the point kernel method to account for scattered radiation through a shielding material. The accuracy of the point kernel method is strongly affected by the correspondence of analyzed parameters to experimental configurations, which is attempted to be simplified here. The point kernel method has not been found to have widespread practical use for neutron shielding calculations due to the complex neutron transport behavior through shielding materials (i.e. the variety of interaction mechanisms that neutrons may undergo while traversing the shield) as well as non-linear neutron total cross section energy dependence. In this work, total ambient dose buildup factors for NBS04 concrete are calculated in terms of neutron and secondary gamma ray transmission factors. The neutron and secondary gamma ray transmission factors are calculated using MCNP6™ code with updated cross sections. Both transmission factors and buildup factors are given in a tabulated form. Practical use of neutron transmission and buildup factors warrants rigorously calculated results with all associated uncertainties. In this work, sensitivity analysis of neutron transmission factors and total buildup factors with varying water content has been conducted. The analysis showed significant impact of varying water content in concrete on both neutron transmission factors and total buildup factors. Finally, support vector regression, a machine learning technique, has been engaged to make a model based on the calculated data for calculation of the buildup factors. The developed model can predict most of the data with 20% relative error.

  1. LEARNERS SATISFACTION FACTORS IN NEUROLOGY RELATED MOOCs

    Directory of Open Access Journals (Sweden)

    Ionela MANIU

    2017-12-01

    Full Text Available The aim of this article is to investigate the factors that are influencing student satisfaction in case of neurology related massive open online courses (MOOCs. We analyzed data collected from learners enrolled in 40 neurology related MOOCs, by manually looking for information in these courses reviews. The main identified satisfaction factors can be grouped into the following categories: content related factors: course content, additional materials, assignments, external research and teaching - learning related factors (teacher presentation techniques / style: engaging, clear, coherent, knowledgeable, sharing / explanation, interactive, excitement, considering student’s needs, inspiring, sense of humor. Competences, skills and objectives pursued by neurology related MOOCs are also discussed. Analyzing these factors can be useful in new courses management (design and implementation and also in understanding the needs (motivation, behaviors, perception of 21st century learners interested in neurology related fields.

  2. Two factors influencing dose reconstruction in low dose range: the variability of BKG intensity on one individual and water content

    International Nuclear Information System (INIS)

    Zhang, Tengda; Zhang, Wenyi; Zhao, Zhixin; Zhang, Haiying; Ruan, Shuzhou; Jiao, Ling

    2016-01-01

    A fast and accurate retrospective dosimetry method for the triage is very important in radiation accidents. Electron paramagnetic resonance (EPR) fingernail dosimetry is a promising way to estimate radiation dose. This article presents two factors influencing dose reconstruction in low dose range: the variability of background signal (BKG) intensity on one individual and water content. Comparing the EPR spectrum of dried and humidified fingernail samples, it is necessary to add a procedure of dehydration before EPR measurements, so as to eliminate the deviation caused by water content. Besides, the BKGs of different fingers' nails are not the same as researchers thought previously, and the difference between maximum and minimum BKG intensities of one individual can reach 55.89 %. Meanwhile, the variability of the BKG intensity among individuals is large enough to impact precise dose reconstruction. Water within fingernails and instability of BKG are two reasons that cause the inaccuracy of radiation dose reconstruction in low-dosage level. (authors)

  3. Human and technical factors in the doses reduction and optimization at Cogema/Marcoule; Facteurs techniques et humains dans la reduction et l'optimisation des doses a Cogema/Marcoule

    Energy Technology Data Exchange (ETDEWEB)

    Bourgogne, J.L. [Cogema, 30 - Marcoule (France)

    1998-07-01

    In the case of Cogema/Marcoule, the constant decrease of radiation doses is attributed to three factors: technical with a surveillance system and doses optimization, relational with the promotion of confidence in teams of radiation protection services as an acceptation factor of radiation protection techniques and psychological with an evolution of minds towards the ALARA approach. (N.C.)

  4. Job related mortality risks of Hanford workers and their relation to cancer effects of measured doses of external radiation

    International Nuclear Information System (INIS)

    Kneale, G.W.; Mancuso, T.F.; Stewart, A.M.

    1984-01-01

    A continuation of the series by Mancuso, Stewart, and Kneale (MSK) on studies of cancer risks for radiation workers at Hanford is presented. It concentrates on the statistical problems posed by the need to estimate and control for job related mortality risks when there are several changes of occupation and no certainty about how different occupations are related to two socioeconomic factors which have strong health associations-namely, education and income. The final conclusion is that for tissues which are sensitive to cancer induced by radiation there is a risk of cancer for Hanford exposures whose dose response is curvilinear with long latency and increasing effect with increasing exposure age. (author)

  5. Comparison of the two different standard flux-to-dose rate conversion factors

    International Nuclear Information System (INIS)

    Metghalchi, M.; Ashrafi, R.

    1983-01-01

    A very useful and simple way of obtaining the dose rate associated with neutron or photon fluxes is to multiply these fluxes by the appropriate flux-to-dose rate conversion factors. Two basic standard flux-to-dose rate conversion factors. are being used in all over the world, those recommended by the International Commission on Radiation Protection (ICRP) and the American National Standars (ANS). The purpose of this paper is to compare these two standard with each other. The comparison proved that the dose rate associated with a specific neutron flux, obtained by the ANS flux-to-dose rate conversion factors is usually higher than those calculated by the ICRP's conversion factors. Whereas in the case of the photon, in all energies, the difference between the dose rates obtained by these two standard flux-to-dose rate conversion factors are noticeable, and the ANS results are higher than the ICRP ones. So, it should be noted that for a specific neutron or photon flux the dose rate obtained by the ANS flux-to-dose rate conversion factors are more conservative than those obtained by the ICRP's. Therefore, in order to establish a more reasonable new standard flux-to-dose rate conversion factors, more work should be done. (author)

  6. Dose titration to reduce dipyridamole-related headache.

    Science.gov (United States)

    Chang, Yeu-Jhy; Ryu, Shan-Jin; Lee, Tsong-Hai

    2006-01-01

    Combination of low-dose aspirin and modified-release dipyridamole (ASA+MR-DP) provides a significantly increased benefit in stroke prevention over aspirin alone. However, headaches were reported in more patients receiving dipyridamole-containing agents than in those receiving placebo. We undertook a randomized, double-blind, placebo-controlled trial to evaluate which dosing regimens of ASA+MR-DP have better tolerance. This trial randomized 146 patients with a history of ischemic cerebrovascular disease into three groups: placebo (days 1-28), reduced dose (placebo on days 1-4, ASA+MR-DP once daily before bed during days 5-14, and b.i.d. on days 15-28), and regular dose (placebo on days 1-4, and ASA+MR-DP b.i.d. on days 5-28). Using Chinese diary card, headache was assessed as mean cumulated headache (Sigma frequency x intensity/occurrence days x study days) over the study period, and was graded 0-4 according to Cancer Therapy Evaluation Program, Common Toxicity Criteria, Version 2.0. Intent-to-treat patients after randomization was 46 in placebo group, 45, reduced dose, and 49, regular dose. Among commonly reported adverse effects, headache of any grade occurred significantly more in the regular dose group (38.8%), as compared to the other two groups (p < 0.05). Mean cumulated headache was higher (p < 0.05) in the regular dose group than in the reduced group during days 5-14. Of 27 patients who dropped out, 15 (55.6%) were due to headache, which was substantially more in regular dose (8, 53.3%), though the difference was statistically insignificant. Initial reduced dose treatment with ASA+MR-DP may cause fewer headaches than regular dosing, and seems better tolerated by those susceptible to phosphodiesterase inhibitor-induced headache. Copyright 2006 S. Karger AG, Basel.

  7. Identification and Characterization of Soluble Factors Involved in Delayed Effects of Low Dose Radiation. Final report

    International Nuclear Information System (INIS)

    Baulch, Janet

    2013-01-01

    This is a 'glue grant' that was part of a DOE Low Dose project entitled 'Identification and Characterization of Soluble Factors Involved in Delayed Effects of Low Dose Radiation'. This collaborative program has involved Drs. David L. Springer from Pacific Northwest National Laboratory (PNNL), John H. Miller from Washington State University, Tri-cities (WSU) and William F. Morgan then from the University of Maryland, Baltimore (UMB). In July 2008, Dr. Morgan moved to PNNL and Dr. Janet E. Baulch became PI for this project at University of Maryland. In November of 2008, a one year extension with no new funds was requested to complete the proteomic analyses. The project stemmed from studies in the Morgan laboratory demonstrating that genomically unstable cells secret a soluble factor or factors into the culture medium, that cause cytogenetic aberrations and apoptosis in normal parental GM10115 cells. The purpose of this project was to identify the death inducing effect (DIE) factor or factors, estimate their relative abundance, identify the cell signaling pathways involved and finally recapitulate DIE in normal cells by exogenous manipulation of putative DIE factors in culture medium. As reported in detail in the previous progress report, analysis of culture medium from the parental cell line, and stable and unstable clones demonstrated inconsistent proteomic profiles as relate to candidate DIE factors. While the proposed proteomic analyses did not provide information that would allow DIE factors to be identified, the analyses provided another important set of observations. Proteomic analysis suggested that proteins associated with the cellular response to oxidative stress and mitochondrial function were elevated in the medium from unstable clones in a manner consistent with mitochondrial dysfunction. These findings correlate with previous studies of these clones that demonstrated functional differences between the mitochondria of stable and unstable clones. These

  8. Identification and Characterization of Soluble Factors Involved in Delayed Effects of Low Dose Radiation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Baulch, Janet

    2013-09-11

    This is a 'glue grant' that was part of a DOE Low Dose project entitled 'Identification and Characterization of Soluble Factors Involved in Delayed Effects of Low Dose Radiation'. This collaborative program has involved Drs. David L. Springer from Pacific Northwest National Laboratory (PNNL), John H. Miller from Washington State University, Tri-cities (WSU) and William F. Morgan then from the University of Maryland, Baltimore (UMB). In July 2008, Dr. Morgan moved to PNNL and Dr. Janet E. Baulch became PI for this project at University of Maryland. In November of 2008, a one year extension with no new funds was requested to complete the proteomic analyses. The project stemmed from studies in the Morgan laboratory demonstrating that genomically unstable cells secret a soluble factor or factors into the culture medium, that cause cytogenetic aberrations and apoptosis in normal parental GM10115 cells. The purpose of this project was to identify the death inducing effect (DIE) factor or factors, estimate their relative abundance, identify the cell signaling pathways involved and finally recapitulate DIE in normal cells by exogenous manipulation of putative DIE factors in culture medium. As reported in detail in the previous progress report, analysis of culture medium from the parental cell line, and stable and unstable clones demonstrated inconsistent proteomic profiles as relate to candidate DIE factors. While the proposed proteomic analyses did not provide information that would allow DIE factors to be identified, the analyses provided another important set of observations. Proteomic analysis suggested that proteins associated with the cellular response to oxidative stress and mitochondrial function were elevated in the medium from unstable clones in a manner consistent with mitochondrial dysfunction. These findings correlate with previous studies of these clones that demonstrated functional differences between the mitochondria of stable and

  9. Dose factors for contamination of skin and clothing

    International Nuclear Information System (INIS)

    Henrichs, K.; Eiberweiser, C.; Paretzke, H.G.

    1985-11-01

    Methods are described for quantifying the radiation dose administered through radioactive contamination of the skin (and of clothing, in an approximative manner). The calculated results are presented in tables. The dose values established are of significance with regard to radiological assessment of contamination for the definition of dose limits, and for use as a criterion to select appropriate decontamination activities. Alpha, beta and monoenergetic electrons are of importance for estimating the absorbed dose in various skin depths, whereas for other body regions (as e.g. body organs) photon radiation has to be considered. The calculations are based on the assumption of homogeneous exposure of the skin, with the linear extension being large compared to the range of the emitted particle radiation. In order to be able to take into account potential penetration of radioactivity into deeper skin layers by diffusion or solution processes, the calculations have been made for contamination into various depths of the horny layers of the epidermis. The scheme of specific absorbed fraction (SAF) served as a basis for the uniform treatment of different radiation types for the calculation of dose values. (orig./HP) [de

  10. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography.

    Science.gov (United States)

    Trattner, Sigal; Halliburton, Sandra; Thompson, Carla M; Xu, Yanping; Chelliah, Anjali; Jambawalikar, Sachin R; Peng, Boyu; Peters, M Robert; Jacobs, Jill E; Ghesani, Munir; Jang, James J; Al-Khalidi, Hussein; Einstein, Andrew J

    2018-01-01

    This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy -1 cm -1 . Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. k-Factors averaged 0.026 mSv·mGy -1 cm -1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy -1 cm -1 . The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy -1 cm -1 ). Cardiac k-factors

  11. Comparison of Radiation Dose Rates with the Flux to Dose Conversion Factors Recommended in ICRP-74 and ICRP-116

    International Nuclear Information System (INIS)

    Jeong, Hae Sun; Kil, A Reum; Lee, Jo Eun; Jeong, Hyo Joon; Kim, Eun Han; Han, Moon Hee; Hwang, Won Tae

    2016-01-01

    The evaluation of radiation shielding has been performed for the design and maintenance of various facilities using radioactive sources such as nuclear fuel, accelerator, and radionuclide. The conversion of flux to dose mainly used in nuclear and radiation fields has been generally made with the dose coefficients presented in ICRP Publication 74 (ICRP- 74), which are produced based on ICRP Publication 60. On the other hand, ICRP Publication 116 (ICRP-116), which adopts the protection system of ICRP Publication 103, has recently been published and provides the dose conversion coefficients calculated with a variety of Monte Carlo codes. The coefficients have more than an update of those in ICRP-74, including new particle types and a greatly expanded energy range. In this study, a shielding evaluation of a specific container for neutron and gamma sources was performed with the MCNP6 code. The dose rates from neutron and gamma-ray sources were calculated using the MCNP6 codes, and these results were based on the flux to dose conversion factors recommended in ICRP-74 and ICRP-116. As a result, the dose rates evaluated with ICRP-74 were generally shown higher than those with ICRP-116. For neutrons, the difference is mainly occurred by the decrease of radiation weighting factors in a part of energy ranges in the ICRP-116 recommendations. For gamma-rays, the ICRP-74 recommendation applied with the kerma approximation leads to overestimated results than the other assessment

  12. Dose conversion factors for radiation doses at normal operation discharges. F. Methods report; Dosomraekningsfaktorer foer normaldriftutslaepp. F. Metodrapport

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Hallberg, Bengt; Karlsson, Sara

    2001-10-01

    A study has been performed in order to develop and extend existing models for dose estimations at emissions of radioactive substances from nuclear facilities in Sweden. This report gives a review of the different exposure pathways that have been considered in the study. Radioecological data that should be used in calculations of radiation doses are based on the actual situation at the nuclear sites. Dose factors for children have been split in different age groups. The exposure pathways have been carefully re-examined, like the radioecological data; leading to some new pathways (e.g. doses from consumption of forest berries, mushrooms and game) for cesium and strontium. Carbon 14 was given a special treatment by using a model for uptake of carbon by growing plants. For exposure from aquatic emissions, a simplification was done by focussing on the territory for fish species, since consumption of fish is the most important pathway.

  13. Ameliorative effects of low dose/low dose-rate irradiation on reactive oxygen species-related diseases model mice

    International Nuclear Information System (INIS)

    Nomura, Takaharu

    2008-01-01

    Living organisms have developed complex biological system which protects themselves against environmental radiation, and irradiation with proper dose, dose-rate and irradiation time can stimulate their biological responses against oxidative stress evoked by the irradiation. Because reactive oxygen species are involved in various human diseases, non-toxic low dose/low dose-rate radiation can be utilized for the amelioration of such diseases. In this study, we used mouse experimental models for fatty liver, nephritis, diabetes, and ageing to elucidate the ameliorative effect of low dose/low dose-rate radiation in relation to endogenous antioxidant activity. Single irradiation at 0.5 Gy ameliorates carbon tetrachloride-induced fatty liver. The irradiation increases hepatic anti-oxidative system involving glutathione and glutathione peroxidase, suggesting that endogenous radical scavenger is essential for the ameliorative effect of low dose radiation on carbon tetrachloride-induced fatty liver. Single irradiation at 0.5 Gy ameliorates ferric nitrilotriacetate-induced nephritis. The irradiation increases catalase and decreases superoxide dismutase in kidney. The result suggests that low dose radiation reduced generation of hydroxide radical generation by reducing cellular hydroperoxide level. Single irradiation at 0.5 Gy at 12 week of age ameliorates incidence of type I diabetes in non-obese diabetic (NOD) mice through the suppression of inflammatory activity of splenocytes, and resultant apoptosis of β-cells in pancreas. The irradiation activities of superoxide dismutase and catalase, which coordinately diminish intracellular reactive oxygen species. Continuous irradiation at 0.70 mGy/hr from 10 week of age elongates life span, and suppresses alopecia in type II diabetesmice. The irradiation improved glucose clearance without affecting insulin-resistance, and increased pancreatic catalase activity. The results suggest that continuous low dose-rate irradiation protect

  14. Guideline values for skin decontamination measures based on nuclidspecific dose equivalent rate factors

    International Nuclear Information System (INIS)

    Pfob, H.; Heinemann, G.

    1992-01-01

    Corresponding dose equivalent rate factors for various radionuclides are now available for determining the skin dose caused by skin contamination. These dose equivalent rate factors take into account all contributions from the types of radiation emitted. Any limits for skin decontamination measures are nowhere contained or determined yet. However, radiological protection does in practice require at least guideline values in order to prevent unsuitable or detrimental measures that can be noticed quite often. New calculations of dose equivalent rate factors for the skin now make the recommendation of guideline values possible. (author)

  15. Introduction: Issues Related to Dose Units and Damage Correlation

    International Nuclear Information System (INIS)

    Stoller, Roger E.

    2012-01-01

    The observable effects of irradiation on material properties are complex and each such property changed depends sensitively on a range of irradiation and material parameters. This works against development of a universal exposure parameter. The irradiation dose to the material (both ionizing and displacement dose) can be calculated with good accuracy as long as the relevant reaction cross sections are known and implemented in the codes used. This suggests that a focus on dose calculations is warranted. When assessing damage correlation parameters, it is important to determine the appropriate dose parameter first. Then a clear distinction between damage formation and damage accumulation needs to be kept in mind. The dose unit is most helpful for estimating the primary damage generation, e.g. how damage energy is used to estimate atomic displacements. However, damage accumulation requires longer times and involves kinetic and thermodynamic processes that cannot be accounted for in a dose or primary damage unit. The adequacy of the primary damage formulations can be assessed through their use in mean field reaction rate theory or kinetic Monte Carlo microstructural evolution models to predict damage accumulation. The results of these models can be directly compared with experimental observations. (author)

  16. Indication-related dosing for magnetic resonance contrast media

    International Nuclear Information System (INIS)

    Yuh, W.T.C.; Parker, J.R.; Carvlin, M.J.

    1997-01-01

    This presentation reviews the issue of contrast media dosing and imaging protocols for the optimal MR imaging detection and characterization of pathology. The cumulative clinical experience gained in performing contrast-enhanced MR examinations with gadolinium chelates indicates that a dose of 0.1 mmol/kg body weight provides safe and effective enhancement of most CNS pathology. Doses lower than 0.1 mmol/kg have been shown to be inadequate for delineating all but selected types of CNS pathology, such as masses with a high lesion to background ratio on post-contrast images (acoustic neuromas) or lesions located in areas in which the normal tissue very rapidly takes up contrast agent (e. g. microadenomas in the pituitary gland). Recent clinical studies have suggested a role for high dose gadolinium administration (up to 0.3 mmol/kg) for the optimal detection and delineation of cerebral metastases or other small or poorly enhancing lesions. Differences in the histopathologic characteristics (capillary permeability, vascularity, location, size) of specific diseased tissues may require varying doses or even a different contrast agent to be used for optimal imaging results. As new MR contrast agents and new scanning techniques are introduced, the specific diagnostic question posed will likely determine the choice of pulse sequence, contrast agent and dose used. (orig.)

  17. Patient absorbed radiation doses estimation related to irradiation anatomy

    International Nuclear Information System (INIS)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes

    2014-01-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector

  18. A method to adjust radiation dose-response relationships for clinical risk factors

    DEFF Research Database (Denmark)

    Appelt, Ane Lindegaard; Vogelius, Ivan R

    2012-01-01

    Several clinical risk factors for radiation induced toxicity have been identified in the literature. Here, we present a method to quantify the effect of clinical risk factors on radiation dose-response curves and apply the method to adjust the dose-response for radiation pneumonitis for patients...

  19. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  20. Lung doses from radon in dwellings and influencing factors

    International Nuclear Information System (INIS)

    Stranden, E.

    1980-01-01

    The radon concentration in Norwegian dwellings and the lung doses received by the Norwegian population are reported. The biological effects of these doses are discussed. The mean value of radon-daughters in Norwegian dwellings was found to be about 7x10 -3 WL (working levels). This corresponds to an annual exposure of about 0.3 WLM (working level months). From studies of the lung cancer statistics of Norway, this exposure may account for about 10% of the annual lung cancer cases in Norway. The variations in the radon concentration inside dwellings are discussed, and the influence of exhalation, ventilation and meteorological parameters upon the respiratory dosage is studied. From the risk estimates performed, the consequences of an increased indoor radon concentration due to reduced ventilation or introduction of building materials with high radium concentrations are discussed. From comparison of the population doses from different sources of radiation, it is evident that a possible future increase in the radon concentration in dwellings is one of the most serious radiation protection problems of our time. (author)

  1. Business factors related to manufacturing firms' performance

    Directory of Open Access Journals (Sweden)

    Stergios Vranakis

    2014-01-01

    Full Text Available Purpose: The main goal is to understand the way many factors affect the investment decision making process and business performance. Design/methodology/approach: This study proposes a new conceptual framework for examining the reasons that manufacturing firms decide to invest on the acquisition of new machinery and equipment in order to improve their infrastructure. It incorporates various factors related to the internal business environment (quality management, investment decisions etc. Findings and Originality/value: A new conceptual framework, establishing the relations between many factors, has been developed, allowing the determinants of adoption of many implications to be discussed and to relate them to the peculiarities of the Greek manufacturing industry. Originality/value: This study presents an overview of the impact of machinery and equipment investment on firm’s performance, giving grasp for further research of the inter-organizational relationships that exist between them. 

  2. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    OpenAIRE

    E. L. Artanova; E. V. Saleeva; I. M. Sokolov; Y. G. Shvarts

    2011-01-01

    Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR) were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, a...

  3. Relative effect of dose-rate values and fractionation on late responding tissues and tumours

    International Nuclear Information System (INIS)

    Malgieri, F.

    1995-01-01

    There are currently available different facilities for radiotherapy also with regard to the dose-rate values (in the ranges LDR - MDR - HDR), sometimes used alternatively or subsequently for the same tumour. We have set up a 'unitary' L-Q model, based on Liversage's and Dale's works, that explicitly include also the dose-rate value and a correction factor of the β parameter depending on the sublethal damage repair time constant, on the length of time of each irradiation and on the time interval between following irradiation for to realize the effect of the incomplete repair when the time interval is short as, for example, in the PLDR. This 'unitary' L-Q model is, of course, usable in the same way both for external beam therapy and for curietherapy and make possible to compute and compare, for each kind of tumour and normal tissue, the relative effect of the different available modality of radiotherapy also with regard to the dose-rate. We show and discuss the resulting relationships of the ratio BED 'late'/BED tumour changing the time-dose parameters and the values of the biological characteristic parameters T p , α/β and μ, for defined size of tumour control and different value of the doserate

  4. Clinical factors related to schizophrenia relapse.

    Science.gov (United States)

    Porcelli, Stefano; Bianchini, Oriana; De Girolamo, Giovanni; Aguglia, Eugenio; Crea, Luciana; Serretti, Alessandro

    2016-01-01

    Relapses represent one of the main problems of schizophrenia management. This article reviews the clinical factors associated with schizophrenia relapse. A research of the last 22 years of literature data was performed. Two-hundred nineteen studies have been included. Three main groups of factors are related to relapse: factors associated with pharmacological treatment, add-on psychotherapeutic treatments and general risk factors. Overall, the absence of a maintenance therapy and treatment with first generation antipsychotics has been associated with higher risk of relapse. Further, psychotherapy add-on, particularly with cognitive behaviour therapy and psycho-education for both patients and relatives, has shown a good efficacy for reducing the relapse rate. Among general risk factors, some could be modified, such as the duration of untreated psychosis or the substance misuse, while others could not be modified as male gender or low pre-morbid level of functioning. Several classes of risk factors have been proved to be relevant in the risk of relapse. Thus, a careful assessment of the risk factors here identified should be performed in daily clinical practice in order to individualise the relapse risk for each patient and to provide a targeted treatment in high-risk subjects.

  5. Calculation of Dose Gamma Ray Build up Factor in Some ...

    African Journals Online (AJOL)

    The gamma ray buildup factor was calculated by analyzing the narrow- beam and broad-beam geometry equations using Taylor's formula for isotropic sources and homogeneous materials. The buildup factor was programmed using MATLAB software to operate with any radiation energy (E), atomic number (Z) and the ...

  6. Talking about Relations : Factors Influencing the Production of Relational Descriptions

    NARCIS (Netherlands)

    Baltaretu, Adriana-Alexandra; Krahmer, Emiel; van Wijk, Carel; Maes, Alfons

    2016-01-01

    In a production experiment (Experiment 1) and an acceptability rating one (Experiment 2), we assessed two factors, spatial position and salience, which may influence the production of relational descriptions (such as “the ball between the man and the drawer”). In Experiment 1, speakers were asked to

  7. Acute non-stochastic effect of very low dose whole-body exposure, a thymidine equivalent serum factor

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Muehlensiepen, H.; Porschen, W.; Booz, J.

    1982-01-01

    Whole-body irradiation of mice causes the dose-dependent appearance of a humoral factor in blood serum which inhibits incorporation of 125-IUdR into tissue culture cells. This factor appears even at doses below 0.01 Gy gamma irradiation and thus is probably not related to cell death. Data are presented relating this humoral factor to thymidine. Since at low doses the target size for this effect was calculated to be the entire cell, a cellular effect is postulated linking the site of few primary absorption events, anywhere in the cell, with the cellular membrane, thus causing changes in membrane charge, structure and/or fluidity. This may lead to blocking thymidine acceptance by the cell, and thus would cause a pile-up of thymidine in the reutilization pathway in peripheral blood and would give rise to the observed effect. The effect appears as a temporary disturbance of the physiological equilibrium and should not be related at present to any cellular damage. The acute low-dose effect described has implications for the measurement of low-dose exposure by biological dosimeters and on basic research on membrane function. (author)

  8. Factors Related to Parenting Practices in Taiwan.

    Science.gov (United States)

    Chen, Fu-Mei; Luster Tom

    2002-01-01

    This study examined factors related to authoritarian and authoritative parenting practices among 463 Chinese mothers with preschoolers in Taiwan. Questionnaire findings suggested that maternal depression, child temperament, and degree of parenting daily hassles might have cross-culturally universal influence on parenting practices. Chinese…

  9. EFFECTS OF PROCUREMENT RELATED FACTORS ON ...

    African Journals Online (AJOL)

    Osondu

    2013-03-04

    Mar 4, 2013 ... Policy makers in government, clients, and private developers into housing projects should give adequate .... constraints, payment method, finding methods and ... price and negotiation of contract details and firm ... All these discussed .... Decision. Cost related factors. 31.83. 3. 9.34. 0.00. S*. Accept H1.

  10. Dose-volume correlation in radiation-related late small-bowel complication

    International Nuclear Information System (INIS)

    Letschert, J.G.J.; Lebesque, J.V.; Boer, R.W. de; hart, A.A.M.; Barteling, H.

    1990-01-01

    The effects of the volume of irradiated small bowel on late small-bowel tolerance was studied, taking into account the equivalent total dose ant type of pre-irradiation surgical procedure. A method was developed to estimate small-bowel volumes in the high-bowel volumes were measured for three-field and AP-PA pelvic treatments (165 cm 3 and 400 cm 3 , respectively), extended AP-PA treatment of para-aortic and iliac nodes (1000 cm 3 ). In a retrospective study of 111 patientst irradiated after surgery for rectal or recto-sigmoid cancer to a dose of 45-50 Gy in 5 weeks, extended AP-PA pelvic treatment (n = 27) resulted in a high incidence of severe small-bowel complications (37%), whereas for limited (three-field) pelvic treatment (n = 84) the complication rate was 6%. These complication data together with data from the literature on postoperative radiation-related small-bowel complications were analysed using the maximum likelihood method to fit the data to the logistic form of the dose-response relation, taking the volume effect into account by a power law. The analysis indicated that the incidence of radiation-related small-bowel compllications was higher after rectal surgery than after other types of surgery, which might be explained by the development of more adhesions. For both types of surgery a volume exponent of the power-law of 0.26 ± 0.05 was established. This means that if the small-bowel volume is increased by a factor of 2, the total dose has to be reduced by 17% for the same incidence of small-bowel complications. (author). 45 refs.; 6 figs.; 4 tabs

  11. Operation of the radiation dose registration system for decontamination and related works

    International Nuclear Information System (INIS)

    Ogawa, Tsubasa; Yasutake, Tsuneo; Itoh, Atsuo; Miyabe, Kenjiro

    2017-01-01

    The radiation dose registration system for decontamination and related works was established on 15 November 2013. Radiation dose registration center and primary contractors of decontamination and related works manage decontamination registration and management system. As of 31 March 2017, 384 primary contractors joined in the radiation dose registration system for decontamination and related works. 383,087 quarterly exposure dose records for decontamination and related works were registered. Based on the registered data provided by the primary contractors, radiation dose registration center has released the statistical data that represent the radiation control status for workers engaged in radiation work at the work areas of decontamination and related works, etc. The statistical data shows that there were 40,377 workers engaged in decontamination and related works in 2015. The average exposure dose for workers was 0.6 mSv in 2015. The maximum exposure dose for workers was 7.8 mSv in 2015. Dose distribution by age of workers shows the range of 60 to 64 years old were most engaged in decontamination and related works in 2015. Dose distribution by gender of workers shows 97% of workers were male in 2015. From 2012 to 2015, about 95% of workers were exposed to radiation less than 3 mSv. And about 80% of workers were exposed to radiation less than 1 mSv. The average exposure dose per year was ranged from 0.5 to 0.7 mSv. (author)

  12. Establishment of source related dose constraints for members of the public. Interim report for comment

    International Nuclear Information System (INIS)

    1992-09-01

    The International Commission on Radiological Protection is proposing a new concept that it terms a ''dose constraint''. A dose constraint is an individual-related criterion applied to a single radiation source, and fixes an upper value for exposure of the critical group from that source. A dose restraint sets a ceiling on the levels of individual dose that can be considered in the optimization of radiological protection for a single source. 6 refs, 1 fig., 2 tabs

  13. Microbiological aspects relating to the choice of radiation sterilization dose

    International Nuclear Information System (INIS)

    Whitby, J.L.

    1993-01-01

    Ionizing radiation is widely used for sterilization of single-use medical devices, and it is employed for its lethal effect on microbial life. Microbes are capable of regenerating from a single surviving cell, and individual cells of some microbial species are highly resistant to the lethal effects of radiation. It is necessary to employ radiation doses far in excess of those lethal to man or animals to ensure that no viable microbe remains to repopulate the device or the patient at the time that the device is used. Ionizations induce the production of short-lived free radicals that also induce lethal changes in cells. The sensitivity of microbial species to these changes varies markedly but since the changes are induced within the cell, each cell has to sustain the necessary amount of lethal damage before death will occur. Therefore the death of cells will occur in the exponential mode the surviving fraction decreasing with increasing dose. Using a semi-logarithmic plot, curves of three types may be generated, a simple exponential curve with a constant slope over the whole dose range, one where an initial shoulder is followed by a constant slope, and curves which are concave, and only seen in mixed bacterial populations of differing radiation resistance. (author)

  14. Present dose limits and their relation to radiosensitivity of different organs and tissues

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Dose equivalent limits in relation to dose thresholds are considered for injury of various tissues and organs to evaluate the protection agains non-stochastic irradiation effects by the existing system of dose limitation for radiotherapeutic personnel. Data on tissue radiosensitivity in relation to non-stochastic effects, obtained from radiotherapeutic experience, are presented. Dose threshold values, derived for patients, with a correction in the direction of increase, may be applied to conditions of occupational exposure except for bone marrow, gonads and eye lens, where threshold doses are lower

  15. The influence of social psychological factors on behaviour, stress and dose in Chernobyl affected areas

    International Nuclear Information System (INIS)

    Murphy, M.; Allen, P.

    1998-01-01

    During the 12 years since the Chernobyl nuclear accident, people in the affected areas have lived day to day with the risks of radiation. During these 12 years many countermeasures have been applied to minimise dose and thus reduce the threat to the health of the affected populations. Some of these countermeasures are aimed at changing daily life; for example, advice and restrictions on behaviours relating to the forest, consumption of forest produce and the consumption of private milk. In order to be effective, these countermeasures require action, or compliance, on the part of the affected populations. How have people in these areas responded to this risk and to the countermeasures employed to minimise the risk? A number of social psychological factors may be involved in peoples responses to this situation, including their perceptions of threat, the perceived costs and benefits of the behaviours involved, and the influence of other people. We examine the influence of these various social psychological factors on compliance behaviour, dose, and stress related health through a survey of people in the affected areas using quantitative questionnaire measures. SPARPA or Social psychological aspects of radiation protection after accidents, is a European Commission-sponsored project (F14C-CT96-0010) involving U. Surrey, Symlog and NRPB as well as partners in the CIS. Specific objectives include: to characterise, using quantitative methods, the nature and psychological impact of countermeasures and the influence of behaviour on dose, and to develop, guidance on the implementation of countermeasures, taking account of the social and psychological context. (authors)

  16. Calculation of dose-rate conversion factors for external exposure to photons and electrons

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1978-01-01

    Methods are presented for the calculation of dose-rate conversion factors for external exposure to photon and electron radiation from radioactive decay. A dose-rate conversion factor is defined as the dose-equivalent rate per unit radionuclide concentration. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each radiation type and exposure mode, dose-rate conversion factors are derived for tissue-equivalent material at the body surface of an exposed individual. In addition, photon dose-rate conversion factors are estimated for 22 body organs. The calculations are based on the assumption that the exposure medium is infinite in extent and that the radionuclide concentration is uniform. The dose-rate conversion factors for immersion in contaminated air and water then follow from the requirement that all of the energy emitted in the radioactive decay is absorbed in the infinite medium. Dose-rate conversion factors for ground-surface exposure are calculated at a reference location above a smooth, infinite plane using the point-kernel integration method and known specific absorbed fractions for photons and electrons in air

  17. Rural settlements: social and ecological factors influencing on internal dose formation

    International Nuclear Information System (INIS)

    Visenberg, Yu.V; Vlasova, N.G.

    2008-01-01

    Full text: The aim of the present study is to reveal the reasons of difference in average internal doses in rural population living in the rural settlements situated on territories with equal levels of soil contamination; to show by clear examples that forming of internal dose is not only influenced directly by the contamination of the territory but also by number of factors of non-radiation origin. There were used data on internal doses as a result of WBC-measurements in rural inhabitants. Method of the study: there was applied the statistical analysis of the internal dose in rural population depending on the number of factors: radio-ecological represented by the transfer factor of radionuclides from soil to milk; environmental - closeness to the forest which, in its turn, determines intake of its resources by rural population; social - the number of population. There were selected settlements for the investigation whose residents had been WBC-measured for the period of 1990-2005's and their doses were evaluated. Thus, the conducted analysis shows that each of indirect (non-radiation) factors contributes in different way into formation of internal dose. The most significant of them is the social factor as follows from the results of the conducted analysis, represented by the number of inhabitants in a settlement. The internal dose depends not only on the level of contamination of the territory but also on the number of other factors: environmental, social, and radio-ecological. The influence of these factors on the process of dose formation in settlements should be considered simultaneously since neither of them is the leading one. Probably, there are other factors influencing on dose formation. Their investigation must be continued. (author)

  18. Happiness and related factors in pregnant women.

    Science.gov (United States)

    Jayasvasti, Kanthika; Kanchanatawan, Buranee

    2005-09-01

    Pregnancy is a crisis in the human life cycle as an important turning point in aspects of anatomical, physiological and psychosocial changes. An unhappy pregnanus could influence the fetal growth and development and sense of maternal competence as well as bonding with the fetus which profoundly affect the nurture of the infant after delivery. The authors'purposes were to study happiness and related factors in pregnant women having antenatal care at King Chulalongkorn Memorial Hospital. Four hundred and thirty-eight pregnant women from the antenatal clinic at King Chulalongkorn Memorial Hospital were randomly selected to complete a set of questionnaires that consisted of personal information, pregnant information, The Oxford Happiness Questionnaire (OHQ), The Maudsley Personality Inventory (MPI) and The Marital Satisfaction Scale (MSS). Prevalence of happiness level was classified by descriptive analysis. Unpaired t-test, ANOVA and Pearson's Product Moment Correlation analyzed related factors to happiness in pregnant woman. Also Stepwise Multiple Regression Analysis was used to define predictive factors for happiness in pregnant women. The sample had a high level of happiness of 57.3%. Significant related factors to happiness were age between 31-35 years, high education level, high individual and family income, having saving deposition, no drug abuse, improved marital relationship, no conflict with relatives, extrovert and stable personality types and no concerns about post-partum body image. Four predictive factors for happiness in pregnant women were extrovert personality, stable personality, high family income and improved marital relationship. Level of happiness in pregnant women could be predicted by type of personality, family income and marital relationship.

  19. Depth dose factors for lymphoma's radiotherapy using a 4 MV linear accelerator

    International Nuclear Information System (INIS)

    Scaff, L.A.M.

    1976-01-01

    In the routine treatment of lymphomas using the mantle technique, the daily doses at the midpoints at five anatomical regions are different because their thickness are not equal. A set of tables of depht dose factors with good precision is presented [pt

  20. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry; Effets sanitaires des faibles doses a faibles debits de dose: modelisation de la relation dose-reponse dans une cohorte de travailleurs du nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Flamant, Camille

    2011-09-19

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  1. Outdoor γ-ray dose rate in Ajigasawa Town and environmental factors affecting it in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shunichi; Sakurai, Naoyuki; Koyama, Kenji

    1999-01-01

    We surveyed the outdoor γ-ray dose rate throughout Aomori Prefecture from 1991 to 1995, and found an annual mean dose rate of 46 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Ajigasawa Town. Glass dosimeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the town. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosimeters showed that the γ-ray dose rates in Ajigasawa Town varied from 48 to 57 nGy h -1 . Although the dose rates were generally higher than the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the town. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in IES. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 27 nGy h -1 and higher than when no precipitation was sensed (23 nGy h -1 ). (author)

  2. Neon-20 depth-dose relations in water

    Science.gov (United States)

    Wilson, J. W.; Townsend, L. W.; Bidasaria, H. B.; Schimmerling, W.; Wong, M.; Howard, J.

    1984-05-01

    The dose from heavy ion beams has been calculated using a one-dimensional transport theory and evaluated for 670 MeV/amu 20 Ne beams in water. The result is presented so as to be applicable to arbitrary ions for which the necessary interaction data are known. The present evaluation is based on thar Silberg-Tsao fragmentation parameters augmented with light fragment production from intranuclear cascades, recently calculated nuclear absorption cross sections, and evaluated stopping power data. Comparison with recent experimental data obtained at the Lawrence Berkeley Laboratory reveals the need for more accurate fragmentation data.

  3. Exposure Scenarios and Unit Dose Factors for the Hanford Immobilized Low Activity Tank Waste Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    RITTMANN, P.D.

    1999-12-29

    Exposure scenarios are defined to identify potential pathways and combinations of pathways that could lead to radiation exposure from immobilized tank waste. Appropriate data and models are selected to permit calculation of dose factors for each exposure

  4. Multivariate analysis of factors predicting prostate dose in intensity-modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Tsuneyuki [Division of Radiology, Osaka Red Cross Hospital, Osaka (Japan); Nakamura, Mitsuhiro, E-mail: m_nkmr@kuhp.kyoto-u.ac.jp [Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Hirose, Yoshinori; Kitsuda, Kenji; Notogawa, Takuya; Miki, Katsuhito [Division of Radiology, Osaka Red Cross Hospital, Osaka (Japan); Nakamura, Kiyonao; Ishigaki, Takashi [Department of Radiation Oncology, Osaka Red Cross Hospital, Osaka (Japan)

    2014-01-01

    We conducted a multivariate analysis to determine relationships between prostate radiation dose and the state of surrounding organs, including organ volumes and the internal angle of the levator ani muscle (LAM), based on cone-beam computed tomography (CBCT) images after bone matching. We analyzed 270 CBCT data sets from 30 consecutive patients receiving intensity-modulated radiation therapy for prostate cancer. With patients in the supine position on a couch with the HipFix system, data for center of mass (COM) displacement of the prostate and the state of individual organs were acquired and compared between planning CT and CBCT scans. Dose distributions were then recalculated based on CBCT images. The relative effects of factors on the variance in COM, dose covering 95% of the prostate volume (D{sub 95%}), and percentage of prostate volume covered by the 100% isodose line (V{sub 100%}) were evaluated by a backward stepwise multiple regression analysis. COM displacement in the anterior-posterior direction (COM{sub AP}) correlated significantly with the rectum volume (δVr) and the internal LAM angle (δθ; R = 0.63). Weak correlations were seen for COM in the left-right (R = 0.18) and superior-inferior directions (R = 0.31). Strong correlations between COM{sub AP} and prostate D{sub 95%} and V{sub 100%} were observed (R ≥ 0.69). Additionally, the change ratios in δVr and δθ remained as predictors of prostate D{sub 95%} and V{sub 100%}. This study shows statistically that maintaining the same rectum volume and LAM state for both the planning CT simulation and treatment is important to ensure the correct prostate dose in the supine position with bone matching.

  5. Relation between dose of bendrofluazide, antihypertensive effect, and adverse biochemical effects

    DEFF Research Database (Denmark)

    Carlsen, J E; Køber, L; Torp-Pedersen, C

    1990-01-01

    OBJECTIVE--To determine the relevant dose of bendrofluazide for treating mild to moderate hypertension. DESIGN--Double blind parallel group trial of patients who were given placebo for six weeks and then randomly allocated to various doses of bendrofluazide (1.25, 2.5, 5, or 10 mg daily) or place...... of bendrofluazide to treat mild to moderate hypertension is 1.25-2.5 mg a day. Higher doses caused more pronounced adverse biochemical effects including adverse lipid effects. Previous trials with bendrofluazide have used too high doses....... relations between dose and effect were shown for potassium, urate, glucose, total cholesterol, and apolipoprotein B concentrations. The 1.25 mg dose increased only urate concentrations, whereas the 10 mg dose affected all the above biochemical variables. CONCLUSION--The relevant range of doses...

  6. Job-related doses in light water reactors

    International Nuclear Information System (INIS)

    Schnuer, K.

    1993-01-01

    The Treaty of 1957 establishing the European Atomic Energy Community, (EURATOM) was an essential prerequisite for the development of a strong nuclear industry in Europe. Among other things the Treaty provides that the Community shall lay down Basic Safety Standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiation and ensure that they are applied. Following adoption of the Council Directive of 1980, the European Commission defined the basic principles of Justification, Optimization and Limitation to be applied in order to ensure the greatest possible protection of workers and the general public. Subsequently the Commission took initiatives in order to find ways of implementing these three basic principles in practical radiation protection. In 1980 the Commission in close collaboration with the leading nuclear power station operators, set up its own system of 'occupational radiation dose statistics from light water reactors operating in Western Europe'. This was designed for PWRs and BWRs, and the Commission benefited from the experience of neighbouring non-EC countries such as Sweden, Finland, Switzerland and Spain (not yet a member) operating nuclear power stations made by different manufacturers. The paper provides some general information on developments and trends in collective and individual doses to workers in nuclear power stations, based on a unique European databank of approximately 1000 operating reactor years. 9 figs

  7. Comparison of biophysical factors influencing on emphysema quantification with low-dose CT

    Science.gov (United States)

    Heo, Chang Yong; Kim, Jong Hyo

    2014-03-01

    Emphysema Index(EI) measurements in MDCT is known to be influenced by various biophysical factors such as total lung volume, and body size. We investigated the association of the four biophysical factors with emphysema index in low-dose MDCT. In particular, we attempted to identify a potentially stronger biophysical factor than total lung volume. A total of 400 low-dose MDCT volumes taken at 120kVp, 40mAs, 1mm thickness, and B30f reconstruction kernel were used. The lungs, airways, and pulmonary vessels were automatically segmented, and two Emphysema Indices, relative area below -950HU(RA950) and 15th percentile(Perc15), were extracted from the segmented lungs. The biophysical factors such as total lung volume(TLV), mode of lung attenuation(ModLA), effective body diameter(EBD), and the water equivalent body diameter(WBD) were estimated from the segmented lung and body area. The association of biophysical factors with emphysema indices were evaluated by correlation coefficients. The mean emphysema indices were 8.3±5.5(%) in RA950, and -930±18(HU) in Perc15. The estimates of biophysical factors were 4.7±1.0(L) in TLV, -901±21(HU) in ModLA, 26.9±2.2(cm) in EBD, and 25.9±2.6(cm) in WBD. The correlation coefficients of biophysical factors with RA950 were 0.73 in TLV, 0.94 in ModLA, 0.31 in EBD, and 0.18 WBD, the ones with Perc15 were 0.74 in TLV, 0.98 in ModLA, 0.29 in EBD, and 0.15 WBD. Study results revealed that two biophysical factors, TLV and ModLA, mostly affects the emphysema indices. In particular, the ModLA exhibited strongest correlation of 0.98 with Perc15, which indicating the ModLA is the most significant confounding biophysical factor in emphysema indices measurement.

  8. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    Directory of Open Access Journals (Sweden)

    E. L. Artanova

    2011-01-01

    Full Text Available Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, amiodarone therapy were considered among clinical characteristics. Results. Adjusted warfarin dose was significantly higher in obesity , and it was lower in case of experienced myocardial infarction. The INR highest levels and maximal amplitudes of its fluctuations were observed in patients with thyroid gland nodes and smokers. Period of warfarin dose titration was longer in patients treated with amiodarone. Conclusion. Warfarin dose titration in patients with atrial fibrillation depends on the presence of myocardial infarction, obesity , thyroid nodular changes, smoking and amiodarone treatment.

  9. Dose conversion factors for inhalation applicable to the mining and milling of radioactive ores

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1992-01-01

    The ICRP recommended revised dose limits for exposure to ionising radiation in November 1990. As well as reducing the annual occupational dose equivalent limit to an average of 20 mSv over 5 years, modified organ weighting factors were recommended, reflecting improved understanding of cancer risk factors for tissues and organs. The adjustment of weighting factors means that derived air concentrations conversion factors and annual limits on intake for exposure to airborne radionuclides are not simply modified by the ratio of the old to the new limits. A recalculation of these factors for radionuclides of interest in the mining and milling of radioactive ores is presented. A computer program for this purpose, based on the ICRP 30 inhalation model, is described. Rapid calculations of dose conversion factors are possible for the naturally occurring radionuclides in the 235 U, 238 U and 232 Th decay chains for which data are given in the supplements to ICRP 30. 7 refs., 12 tabs., 5 figs

  10. Age-specific radiation dose commitment factors for a one-year chronic intake

    International Nuclear Information System (INIS)

    Hoenes, G.R.; Soldat, J.K.

    1977-11-01

    During the licensing process for nuclear facilities, radiation doses and dose commitments must be calculated for people in the environs of a nuclear facility. These radiation doses are determined by examining characteristics of population groups, pathways to people, and radionuclides found in those pathways. The pertinent characteristics, which are important in the sense of contributing a significant portion of the total dose, must then be analyzed in depth. Dose factors are generally available for adults, see Reference 1 for example, however numerous improvements in data on decay schemes and half-lives have been made in recent years. In addition, it is advisable to define parameters for calculation of the radiation dose for ages other than adults since the population surrounding nuclear facilities will be composed of various age groups. Further, since infants, children, and teens may have higher rates of intake per unit body mass, it is conceivable that the maximally exposed individual may not be an adult. Thus, it was necessary to develop new radiation-dose commitment factors for various age groups. Dose commitment factors presented in this report have been calculated for a 50-year time period for four age groups

  11. Computational assessment of effective dose and patient specific doses for kilovoltage stereotactic radiosurgery of wet age-related macular degeneration

    Science.gov (United States)

    Hanlon, Justin Mitchell

    Age-related macular degeneration (AMD) is a leading cause of vision loss and a major health problem for people over the age of 50 in industrialized nations. The current standard of care, ranibizumab, is used to help slow and in some cases stabilize the process of AMD, but requires frequent invasive injections into the eye. Interest continues for stereotactic radiosurgery (SRS), an option that provides a non-invasive treatment for the wet form of AMD, through the development of the IRay(TM) (Oraya Therapeutics, Inc., Newark, CA). The goal of this modality is to destroy choroidal neovascularization beneath the pigment epithelium via delivery of three 100 kVp photon beams entering through the sclera and overlapping on the macula delivering up to 24 Gy of therapeutic dose over a span of approximately 5 minutes. The divergent x-ray beams targeting the fovea are robotically positioned and the eye is gently immobilized by a suction-enabled contact lens. Device development requires assessment of patient effective dose, reference patient mean absorbed doses to radiosensitive tissues, and patient specific doses to the lens and optic nerve. A series of head phantoms, including both reference and patient specific, was derived from CT data and employed in conjunction with the MCNPX 2.5.0 radiation transport code to simulate treatment and evaluate absorbed doses to potential tissues-at-risk. The reference phantoms were used to evaluate effective dose and mean absorbed doses to several radiosensitive tissues. The optic nerve was modeled with changeable positions based on individual patient variability seen in a review of head CT scans gathered. Patient specific phantoms were used to determine the effect of varying anatomy and gaze. The results showed that absorbed doses to the non-targeted tissues were below the threshold levels for serious complications; specifically the development of radiogenic cataracts and radiation induced optic neuropathy (RON). The effective dose

  12. American National Standard: neutron and gamma-ray flux-to-dose rate factors

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard presents data recommended for computing biological dose rates due to neutron and gamma-ray radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are given; the energy range for the gamma-ray conversion factors is 0.01 to 15 MeV. Specifically, this Standard is intended for use by shield designers to calculate wholebody dose rates to radiation workers and the general public. Establishing dose-rate limits is outside the scope of this Standard. Use of this Standard in cases where the dose equivalents are far in excess of occupational exposure guidelines is not recommended

  13. Landscape dose conversion factors used in the safety assessment SR-Site

    International Nuclear Information System (INIS)

    Avila, Rodolfo; Ekstroem, Per-Anders; Aastrand, Per-Gustav

    2010-12-01

    In this report two types of Dose Conversion Factors have been derived: i) a Landscape Dose Conversion Factor (LDF) that is applicable to continuous long-term releases to the biosphere at a constant rate, and ii) a Landscape Dose Conversion Factor for pulse releases (LDF pulse) that is applicable to a radionuclide release that reaches the biosphere in a pulse within years to hundreds of years. In SR-Site these Dose Factors are multiplied with modelled release rates or pulse releases from the geosphere to obtain dose estimates used in assessment of compliance with the regulatory risk criterion. The LDFs were calculated for three different periods of the reference glacial cycle; a period of submerged conditions following the deglaciation, the temperate period, and a prolonged period of periglacial conditions. Additionally, LDFs were calculated for the global warming climate case. The LDF pulse was calculated only for temperate climate conditions. The LDF and LDF pulse can be considered as Best Estimate values, which can be used in calculations of Best Estimate values of doses to a representative individual of the most exposed group from potential releases from a future repository. A systematic analysis of the effects of system, model and parameter uncertainties on the LDFs has been carried out. This analysis has shown that the use of the derived LDF would lead to cautious or realistic dose estimates. The models and methods that were used for derivation of the LDFs and LDF pulse are also described in this report

  14. Landscape dose conversion factors used in the safety assessment SR-Site

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo; Ekstroem, Per-Anders; Aastrand, Per-Gustav (Facilia AB (Sweden))

    2010-12-15

    In this report two types of Dose Conversion Factors have been derived: i) a Landscape Dose Conversion Factor (LDF) that is applicable to continuous long-term releases to the biosphere at a constant rate, and ii) a Landscape Dose Conversion Factor for pulse releases (LDF pulse) that is applicable to a radionuclide release that reaches the biosphere in a pulse within years to hundreds of years. In SR-Site these Dose Factors are multiplied with modelled release rates or pulse releases from the geosphere to obtain dose estimates used in assessment of compliance with the regulatory risk criterion. The LDFs were calculated for three different periods of the reference glacial cycle; a period of submerged conditions following the deglaciation, the temperate period, and a prolonged period of periglacial conditions. Additionally, LDFs were calculated for the global warming climate case. The LDF pulse was calculated only for temperate climate conditions. The LDF and LDF pulse can be considered as Best Estimate values, which can be used in calculations of Best Estimate values of doses to a representative individual of the most exposed group from potential releases from a future repository. A systematic analysis of the effects of system, model and parameter uncertainties on the LDFs has been carried out. This analysis has shown that the use of the derived LDF would lead to cautious or realistic dose estimates. The models and methods that were used for derivation of the LDFs and LDF pulse are also described in this report

  15. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.

    1995-01-01

    A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended

  16. Relation between depression and sociodemographic factors

    Directory of Open Access Journals (Sweden)

    Akhtar-Danesh Noori

    2007-09-01

    Full Text Available Abstract Background Depression is one of the most common mental disorders in Western countries and is related to increased morbidity and mortality from medical conditions and decreased quality of life. The sociodemographic factors of age, gender, marital status, education, immigrant status, and income have consistently been identified as important factors in explaining the variability in depression prevalence rates. This study evaluates the relationship between depression and these sociodemographic factors in the province of Ontario in Canada using the Canadian Community Health Survey, Cycle 1.2 (CCHS-1.2 dataset. Methods The CCHS-1.2 survey classified depression into lifetime depression and 12-month depression. The data were collected based on unequal sampling probabilities to ensure adequate representation of young persons (15 to 24 and seniors (65 and over. The sampling weights were used to estimate the prevalence of depression in each subgroup of the population. The multiple logistic regression technique was used to estimate the odds ratio of depression for each sociodemographic factor. Results The odds ratio of depression for men compared with women is about 0.60. The lowest and highest rates of depression are seen among people living with their married partners and divorced individuals, respectively. Prevalence of depression among people who live with common-law partners is similar to rates of depression among separated and divorced individuals. The lowest and highest rates of depression based on the level of education is seen among individuals with less than secondary school and those with "other post-secondary" education, respectively. Prevalence of 12-month and lifetime depression among individuals who were born in Canada is higher compared to Canadian residents who immigrated to Canada irrespective of gender. There is an inverse relation between income and the prevalence of depression (p Conclusion The patterns uncovered in this

  17. Risk factors for age-related maculopathy.

    Science.gov (United States)

    Connell, Paul P; Keane, Pearse A; O'Neill, Evelyn C; Altaie, Rasha W; Loane, Edward; Neelam, Kumari; Nolan, John M; Beatty, Stephen

    2009-01-01

    Age-related maculopathy (ARM) is the leading cause of blindness in the elderly. Although beneficial therapeutic strategies have recently begun to emerge, much remains unclear regarding the etiopathogenesis of this disorder. Epidemiologic studies have enhanced our understanding of ARM, but the data, often conflicting, has led to difficulties with drawing firm conclusions with respect to risk for this condition. As a consequence, we saw a need to assimilate the published findings with respect to risk factors for ARM, through a review of the literature appraising results from published cross-sectional studies, prospective cohort studies, case series, and case control studies investigating risk for this condition. Our review shows that, to date, and across a spectrum of epidemiologic study designs, only age, cigarette smoking, and family history of ARM have been consistently demonstrated to represent risk for this condition. In addition, genetic studies have recently implicated many genes in the pathogenesis of age-related maculopathy, including Complement Factor H, PLEKHA 1, and LOC387715/HTRA1, demonstrating that environmental and genetic factors are important for the development of ARM suggesting that gene-environment interaction plays an important role in the pathogenesis of this condition.

  18. Risk Factors for Age-Related Maculopathy

    Directory of Open Access Journals (Sweden)

    Paul P. Connell

    2009-01-01

    Full Text Available Age-related maculopathy (ARM is the leading cause of blindness in the elderly. Although beneficial therapeutic strategies have recently begun to emerge, much remains unclear regarding the etiopathogenesis of this disorder. Epidemiologic studies have enhanced our understanding of ARM, but the data, often conflicting, has led to difficulties with drawing firm conclusions with respect to risk for this condition. As a consequence, we saw a need to assimilate the published findings with respect to risk factors for ARM, through a review of the literature appraising results from published cross-sectional studies, prospective cohort studies, case series, and case control studies investigating risk for this condition. Our review shows that, to date, and across a spectrum of epidemiologic study designs, only age, cigarette smoking, and family history of ARM have been consistently demonstrated to represent risk for this condition. In addition, genetic studies have recently implicated many genes in the pathogenesis of age-related maculopathy, including Complement Factor H, PLEKHA 1, and LOC387715/HTRA1, demonstrating that environmental and genetic factors are important for the development of ARM suggesting that gene-environment interaction plays an important role in the pathogenesis of this condition.

  19. Factors Related to Suicide in LGBT Populations.

    Science.gov (United States)

    Skerrett, Delaney Michael; Kõlves, Kairi; De Leo, Diego

    2016-09-01

    There is evidence of heightened vulnerability to nonfatal suicidal behaviors among LGBT populations yet a paucity of studies into fatal behaviors. The specific aim of this article was to identify factors related to suicide in LGBT individuals in Australia. The psychological autopsy (PA) method with a matched case-control study design was used. PA interviews were conducted with 27 next-of-kin of an LGBT person that had died by suicide. Three living LGBT controls per suicide case, matched by age and gender, were also interviewed. The key factors relating to suicide in LGBT people were a lack of acceptance by family and self (reflected in higher internalized homophobia and shame), negative feelings about own sexuality/gender, and dissatisfaction with appearance. LGBT people who died by suicide also tended to go through coming out milestones 2 years earlier than controls. There was a higher prevalence of aggressive behaviors and a more predominant history of physical and sexual abuse. Additionally, there was greater incidence of depression and anxiety and alcohol and substance use disorders. Specific predictive factors for suicide in LGBT populations in Australia were identified, including significantly poorer mental health outcomes and more violence across an array of measures.

  20. Risk factors for age-related maculopathy.

    LENUS (Irish Health Repository)

    Connell, Paul P

    2012-02-01

    Age-related maculopathy (ARM) is the leading cause of blindness in the elderly. Although beneficial therapeutic strategies have recently begun to emerge, much remains unclear regarding the etiopathogenesis of this disorder. Epidemiologic studies have enhanced our understanding of ARM, but the data, often conflicting, has led to difficulties with drawing firm conclusions with respect to risk for this condition. As a consequence, we saw a need to assimilate the published findings with respect to risk factors for ARM, through a review of the literature appraising results from published cross-sectional studies, prospective cohort studies, case series, and case control studies investigating risk for this condition. Our review shows that, to date, and across a spectrum of epidemiologic study designs, only age, cigarette smoking, and family history of ARM have been consistently demonstrated to represent risk for this condition. In addition, genetic studies have recently implicated many genes in the pathogenesis of age-related maculopathy, including Complement Factor H, PLEKHA 1, and LOC387715\\/HTRA1, demonstrating that environmental and genetic factors are important for the development of ARM suggesting that gene-environment interaction plays an important role in the pathogenesis of this condition.

  1. Peripheral intravenous catheter-related phlebitis and related risk factors.

    Science.gov (United States)

    Nassaji-Zavareh, M; Ghorbani, R

    2007-08-01

    Peripheral intravenous catheter-related phlebitis is a common and significant problem in clinical practice. This study aims to investigate the incidence of phlebitis and to evaluate some important related factors. 300 patients admitted to medical and surgical wards of hospitals in Semnan, Iran from April 2003 to February 2004 were prospectively studied. Variables evaluated were age, gender, site and size of catheter, type of insertion and underlying conditions (diabetes mellitus, trauma, infectious disease and burns). Phlebitis was defined when at least four criteria were fulfilled (erythema, pain, tenderness, warmth, induration, palpable cord and swelling). Any patient who was discharged or their catheter removed before three days were excluded. Phlebitis occurred in 26 percent (95 percent confidence interval [CI] 21- 31 percent) of patients. There was no significant relationship between age, catheter bore size, trauma and phlebitis. Related risk factors were gender (odds-ratio [OR] 1.50, 95 percent CI 1.01-2.22), site (OR 3.25, 95 percent CI 2.26-4.67) and type of insertion (OR 2.04, 95 percent CI 1.36-3.05) of catheter, diabetes mellitus (OR 7.78, 95 percent CI 4.59-13.21), infectious disease (OR 6.21, 95 percent CI 4.27-9.03) and burns (OR 3.96, 95 percent CI 3.26-4.82). Phlebitis is still an important and ongoing problem in medical practice. In patients with diabetes mellitus and infectious diseases, more attention is needed.

  2. The study of mean glandular dose in mammography in Yazd and the factors affecting it

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Mostaar, A.; Ghasemi, A.; Ehramposh, M. H.; Khosravi, H.

    2006-01-01

    The objective of this study was to determine the mean glandular dose resulting from mammography examinations in Yazd, southeastern Iran and to identify the factors affecting it. Patients and Methods: This survey was conducted during May to December 2005 to estimate the mean glandular dose for women undergoing mammography and to report the distribution of dose. compressed breast thickness, glandular tissue content, and mammography technique used. The clinical data were collected from 946 mammograms taken from 246 women who were referred to four mammography centers. The mammography instruments in these centers were four modern units with a molybdenum anode and either molybdenum or rhodium filter. The exposure conditions of each mammogram were recorded. The breast glandular content of each mammogram was estimated by a radiologist. The mean glandular dose was calculated based on measuring the normalized entrance skin dose in air. half value layer, kVp, mAs, breast thickness and glandular content. Half value layer, kVp and entrance skin dose were measured by a solid-state detector. The analytical method of Sobol et al. was used for calculation of mean glandular dose . Results: The mean±SD mean glandular dose per film was.2±0.6 mGy for cranio caudal and 1.63±O.9 mGy for mediolateral oblique views. The mean±SD mean glandular dose per woman was 5.5 3.1.mGy. A positive correlation was found between the beam Half value layer with mean glandular dose (r=O.38) and the breast thickness with mean glandular dose (r=O.5). Conclusion: The mean±SD mean glandular dose per film of 1.42±0.8 mGy in present study was lower than most of similar reports. However, the mean mean glandular dose per woman was higher than that in other studies

  3. Aerosol particle size distribution in building and caves: impact to the radon-related dose evaluation

    International Nuclear Information System (INIS)

    Berka, Z.; Thinova, L.; Brandejsova, E.; Zdimal, V.; Fronka, A.; Milka, D.

    2004-01-01

    The results of evaluation of the aerosol particle size spectra observed in the Bozkov cave are presented and compared with the spectra observed in residential areas. The radon-to-dose conversion factor is discussed, as is the correction factor referred to as the cave factor. (P.A.)

  4. Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1)

    International Nuclear Information System (INIS)

    Sato, Osamu; Uehara, Takashi; Yoshizawa, Nobuaki; Iwai, Satoshi; Tanaka, Shun-ichi.

    1992-09-01

    Computer code system and basic data have been investigated for evaluating fluence to dose equivalent conversion factors for photons and neutrons up to 10 GeV. The present work suggested that the conversion factors would be obtained by incorporating effective quality factors of charged particles into the HERMES (High Energy Radiation Monte Carlo Elaborate System) code system. The effective quality factors for charged particles were calculated on the basis of the Q-L relationships specified in the ICRP Publication-60. (author)

  5. Lead-210, bismuth-210, polonium-210. Natural activity, internal dosimetry, and dose factors for ingestion and inhalation

    International Nuclear Information System (INIS)

    Jacobi, W.

    1979-02-01

    Starting with a comprehensive review of the normal, natural activity of 210 Pb and 210 Po in the environment and in the tissues of the human body, a model of the activity and dose distributions of this nuclides in the human body is developed. Dose factors for ingestion with food and for inhalation are derived from this model, related to the intake rate unit. This 'natural exposure model' can be used for an estimation of the population exposure due to normal natural radiation as well as to man-made sourcess of these nuclides, e.g. coal-fired power plants. (orig.) [de

  6. Dose-Related Effect of Extracorporeal Shock Wave Therapy for Plantar Fasciitis

    Science.gov (United States)

    Lee, Su-Jin; Kang, Jung-Ho; Kim, Ja-Young; Kim, Jin-Hong; Jung, Kwang-Ik

    2013-01-01

    Objective To examine the dose-related effect of extracorporeal shock wave therapy (ESWT) for plantar fasciitis. Methods Sixty patients with plantar fasciitis despite conservative treatment were enrolled. The patients were divided into a low-energy group (group L: n=30, 1,000 shocks/session, energy flux density [EFD] per shock 0.08 mJ/mm2) and a medium-energy group (group M: n=30, 1,000 shocks/session, EFD 0.16 mJ/mm2). The main outcome measures were visual analogue scale (VAS), Roles and Maudsley (RM) score, and thickness of plantar fascia (PF). To compare the effects between each group, follow-up was carried out 1 week after 3 and 6 sessions, and 1 and 3 months after ESWT. Results Significant VAS and RM score improvement, and PF thickness reduction were observed in both groups (p0.05). Conclusion Therapeutic effect might disclose a dose-related relationship; therefore, EFD and the times of the session are considerable factors when treating with ESWT. PMID:23869336

  7. Factors related to attempted suicide in Davanagere

    Directory of Open Access Journals (Sweden)

    Nagendra Gouda M

    2008-01-01

    Full Text Available Research Question: What are the factors responsible for suicidal attempts? Objectives: To study the socio-demographic factors, methods and reasons for suicidal attempts. Type of Study: Cross-sectional study. Setting: Bapuji and C.G. Hospitals attached to J.J.M. Medical College, Davanagere. Participants: A total of 540 suicidal attempters admitted to emergency wards. Methodology: A pretested proforma was administered to the subjects relating the factors responsible for the attempt. The data thus obtained was compiled and analyzed. Statistical Analysis: Proportions, Z -test and Chi-square test. Results: In this study, 61.3% were males and 38.7% were females. Peak occurrence of suicidal attempts was found in the second and third decades (15-29 years. Hindus constituted about 94.6% of the total suicidal attempters. Almost half (52.2% of the subjects had education below or up to matriculation and 83% of them were from the lower (classes IV and V socio-economic groups. Agriculturists, housewives and unskilled workers represented 75% of the total subjects. Fifty-five percent of the subjects were from nuclear families and most (62.4% of them were married; frequent mode of attempting suicides was by organo-phosphorus compounds (66.3% followed by overdosage of tablets (17.8%. Common cause was family problem (27.2% followed by illness (27%.

  8. Experimental RBE values of high LET radiations at low doses and the implications for quality factor assignment

    International Nuclear Information System (INIS)

    Sinclair, W.K.

    1985-01-01

    RBE determinations of special relevance to the quality factor assigned for radiation protection purposes are those relating to the effects of special importance at low doses, namely carcinogenesis and mutagenesis. Measurements of RBE that enable the maximum value of RBE, namely RBEsub(M), to be determined at low doses require data points as low as 0.1 Gy or even 0.01 Gy or high LET radiation. Corresponding data points as low as 0.5 Gy to 0.25 Gy or less of low LET radiation are also needed. Relatively few such measurements have been made, but many more are available now than formerly. A review of recent RBEs for tumour induction, life shortening, transformation, cytogenetics and genetic endpoints, which updated an earlier review, indicates a broad range of results. The principle findings are that X rays are more effective than hard γ rays at low doses by a factor of about 2, and that fission neutrons, alpha particles and heavy ions may be 30-50 times more effective, on the average, (some endpoints give higher, some lower values) than hard γ rays. The data would seem to indicate that in order to provide approximately equal protection against the risks at low doses from all radiations, adjustments upward in the quality factors for high LET radiations need to be considered. (author)

  9. I-131 Dose Response for Incident Thyroid Cancers in Ukraine Related to the Chornobyl Accident

    OpenAIRE

    Brenner, Alina V.; Tronko, Mykola D.; Hatch, Maureen; Bogdanova, Tetyana I.; Oliynik, Valery A.; Lubin, Jay H.; Zablotska, Lydia B.; Tereschenko, Valery P.; McConnell, Robert J.; Zamotaeva, Galina A.; O?Kane, Patrick; Bouville, Andre C.; Chaykovskaya, Ludmila V.; Greenebaum, Ellen; Paster, Ihor P.

    2011-01-01

    Background: Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case?control studies, and studies of prevalent cancers. Objective: To address this limitation, we evaluated the dose?response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. Methods: The cohort consists of individuals < 18 years of age on 26 April 1986 who ...

  10. Comparison of 3-Factor Prothrombin Complex Concentrate and Low-Dose Recombinant Factor VIIa for Warfarin Reversal

    OpenAIRE

    Chapman, Scott A; Irwin, Eric D; Abou-Karam, Nada M; Rupnow, Nichole M; Hutson, Katherine E; Vespa, Jeffrey; Roach, Robert M

    2014-01-01

    Introduction Prothrombin complex concentrate (PCC) and recombinant Factor VIIa (rFVIIa) have been used for emergent reversal of warfarin anticoagulation. Few clinical studies have compared these agents in warfarin reversal. We compared warfarin reversal in patients who received either 3 factor PCC (PCC3) or low-dose rFVIIa (LDrFVIIa) for reversal of warfarin anticoagulation. Methods Data were collected from medical charts of patients who received at least one dose of PCC3 (20 units/kg) or LDr...

  11. Quality factor and dose equivalent investigations aboard the Soviet Space Station Mir

    Science.gov (United States)

    Bouisset, P.; Nguyen, V. D.; Parmentier, N.; Akatov, Ia. A.; Arkhangel'Skii, V. V.; Vorozhtsov, A. S.; Petrov, V. M.; Kovalev, E. E.; Siegrist, M.

    1992-07-01

    Since Dec 1988, date of the French-Soviet joint space mission 'ARAGATZ', the CIRCE device, had recorded dose equivalent and quality factor values inside the Mir station (380-410 km, 51.5 deg). After the initial gas filling two years ago, the low pressure tissue equivalent proportional counter is still in good working conditions. Some results of three periods are presented. The average dose equivalent rates measured are respectively 0.6, 0.8 and 0.6 mSv/day with a quality factor equal to 1.9. Some detailed measurements show the increasing of the dose equivalent rates through the SAA and near polar horns. The real time determination of the quality factors allows to point out high linear energy transfer events with quality factors in the range 10-20.

  12. Dose-to-risk conversion factors for low-level tritium exposures

    International Nuclear Information System (INIS)

    Straume, T.

    1992-01-01

    During the past decade, a large number of radiobiological studies have become available for tritium-many of them focusing on the relative biological effectiveness (RBE) of tritium beta rays. These and previous studies indicate that tritium in body water produces the same spectrum of radiogenic effects, e.g., cancer, genetic effects, developmental abnormalities, and reproductive effects, observed following whole-body exposure to penetrating radiations such as gamma rays and x rays. The only significant difference in biological response between tritium beta-rays and the other common low linear-energy transfer (LET) radiations, such as gamma rays and x rays, appears to be the greater biological effectiveness of tritium beta rays. For example, tritium in the oxide form (HTO) is about 2 to 3 times more effective at low doses or low dose rates than gamma rays from 137 Cs or 60 CO (Straume, 1991). When tritium is bound to organic molecules, RBE values may be somewhat larger than those for HTO. It is now clear from the wealth of tritium data available that RBEs for tritium beta rays are higher than the quality factor of unity generally used in radiation protection

  13. Is the ICRP-26 weighting factor for gonadal dose appropriate for new federal regulations?

    International Nuclear Information System (INIS)

    Drum, D.E.

    1991-01-01

    In 1977 the ICRP recommended that computation of the occupational whole body effective dose equivalent include individual organ dose weighting factors derived from risk coefficients for stochastic effects. The-preeminent weighting factor of 0.25 was assigned to irradiation of the gonads in order to account for heritable genetic effects manifest in later generations. As of 1990, there exists no positive significant evidence for the occurrence of transmitted genetic effects in humans after radiation of any form, dose, or dose rate. To assign to gonads 25% of the health detriment from radiation has no basis in medical experience. It establishes a policy that may underestimate the proportion of real mortality from other more radiosensitive organs, and the policy could compromise unreasonably the occupational stability of workers whose activities may involve gonadal irradiation

  14. Relapse of imported Plasmodium vivax malaria is related to primaquine dose: a retrospective study

    Directory of Open Access Journals (Sweden)

    Townell Nicola

    2012-06-01

    Full Text Available Abstract Background Relapsing Plasmodium vivax infection results in significant morbidity for the individual and is a key factor in transmission. Primaquine remains the only licensed drug for prevention of relapse. To minimize relapse rates, treatment guidelines have recently been revised to recommend an increased primaquine dose, aiming to achieve a cumulative dose of ≥6 mg/kg, i.e. ≥420 mg in a 70 kg patient. The aims of this study were to characterize the epidemiology of P. vivax infection imported into Queensland Australia, to determine the rates of relapse, to investigate the use of primaquine therapy, and its efficacy in the prevention of relapse. Methods A retrospective study was undertaken of laboratory confirmed P. vivax infection presenting to the two major tertiary hospitals in Queensland, Australia between January 1999 and January 2011. Primaquine dosing was classified as no dose, low dose ( Results Twenty relapses occurred following 151 primary episodes of P. vivax infection (13.2%. Relapses were confirmed among 3/21 (14.2%, 9/50 (18.0%, 1/54 (1.9% and 7/18 (38.9% of patients administered no dose, low dose, high dose and unknown primaquine dose respectively. High dose primaquine therapy was associated with a significantly lower rate of relapse compared to patients who were prescribed low dose therapy (OR 11.6, 95% CI 1.5-519, p = 0.005. Conclusions Relapse of P. vivax infection is more likely in patients who received low dose primaquine therapy. This study supports the recommendations that high dose primaquine therapy is necessary to minimize relapse of P. vivax malaria.

  15. On the use of quality factors and fluence to dose rate conversion in human radiation exposures

    Science.gov (United States)

    Sondhaus, C. A.

    1972-01-01

    It is shown that various combinations of numbers and factors arrive at estimates of dose and dose effectiveness from values of fluence; but as yet it has not been possible to use biological data with the same degree of precision to estimate the physical data. It would seem that the most reasonable way to use the human data that exist is to apply them as far as possible to the human animal as a whole.

  16. Factors controlling upper tropospheric relative humidity

    Directory of Open Access Journals (Sweden)

    B. Kärcher

    2004-03-01

    Full Text Available Factors controlling the distribution of relative humidity in the absence of clouds are examined, with special emphasis on relative humidity over ice (RHI under upper tropospheric and lower stratospheric conditions. Variations of temperature are the key determinant for the distribution of RHI, followed by variations of the water vapor mixing ratio. Multiple humidity modes, generated by mixing of different air masses, may contribute to the overall distribution of RHI, in particular below ice saturation. The fraction of air that is supersaturated with respect to ice is mainly determined by the distribution of temperature. The nucleation of ice in cirrus clouds determines the highest relative humdity that can be measured outside of cirrus clouds. While vertical air motion and ice microphysics determine the slope of the distributions of RHI, as shown in a separate study companion (Haag et al., 2003, clouds are not required to explain the main features of the distributions of RHI below the ice nucleation threshold. Key words. Atmospheric composition and structure (pressure, density and temperature; troposphere – composition and chemistry; general or miscellaneous

  17. Factors controlling upper tropospheric relative humidity

    Directory of Open Access Journals (Sweden)

    B. Kärcher

    2004-03-01

    Full Text Available Factors controlling the distribution of relative humidity in the absence of clouds are examined, with special emphasis on relative humidity over ice (RHI under upper tropospheric and lower stratospheric conditions. Variations of temperature are the key determinant for the distribution of RHI, followed by variations of the water vapor mixing ratio. Multiple humidity modes, generated by mixing of different air masses, may contribute to the overall distribution of RHI, in particular below ice saturation. The fraction of air that is supersaturated with respect to ice is mainly determined by the distribution of temperature. The nucleation of ice in cirrus clouds determines the highest relative humdity that can be measured outside of cirrus clouds. While vertical air motion and ice microphysics determine the slope of the distributions of RHI, as shown in a separate study companion (Haag et al., 2003, clouds are not required to explain the main features of the distributions of RHI below the ice nucleation threshold.

    Key words. Atmospheric composition and structure (pressure, density and temperature; troposphere – composition and chemistry; general or miscellaneous

  18. Dose and time relations in Hg(++)-induced tubular necrosis and regeneration

    DEFF Research Database (Denmark)

    Nielsen, J B; Andersen, H R; Andersen, O

    1994-01-01

    relationship is caused by a dose-related induction of kidney damage leading to increasing leakage of mercury through the kidneys. Histopathologic investigation revealed extensive necrosis of the proximal tubules in kidneys from mice exposed to 100 mumole HgCl2/kg or higher doses. Moreover, maximum renal damage...

  19. Final Aperture Superposition Technique applied to fast calculation of electron output factors and depth dose curves

    International Nuclear Information System (INIS)

    Faddegon, B.A.; Villarreal-Barajas, J.E.

    2005-01-01

    The Final Aperture Superposition Technique (FAST) is described and applied to accurate, near instantaneous calculation of the relative output factor (ROF) and central axis percentage depth dose curve (PDD) for clinical electron beams used in radiotherapy. FAST is based on precalculation of dose at select points for the two extreme situations of a fully open final aperture and a final aperture with no opening (fully shielded). This technique is different than conventional superposition of dose deposition kernels: The precalculated dose is differential in position of the electron or photon at the downstream surface of the insert. The calculation for a particular aperture (x-ray jaws or MLC, insert in electron applicator) is done with superposition of the precalculated dose data, using the open field data over the open part of the aperture and the fully shielded data over the remainder. The calculation takes explicit account of all interactions in the shielded region of the aperture except the collimator effect: Particles that pass from the open part into the shielded part, or visa versa. For the clinical demonstration, FAST was compared to full Monte Carlo simulation of 10x10,2.5x2.5, and 2x8 cm 2 inserts. Dose was calculated to 0.5% precision in 0.4x0.4x0.2 cm 3 voxels, spaced at 0.2 cm depth intervals along the central axis, using detailed Monte Carlo simulation of the treatment head of a commercial linear accelerator for six different electron beams with energies of 6-21 MeV. Each simulation took several hours on a personal computer with a 1.7 Mhz processor. The calculation for the individual inserts, done with superposition, was completed in under a second on the same PC. Since simulations for the pre calculation are only performed once, higher precision and resolution can be obtained without increasing the calculation time for individual inserts. Fully shielded contributions were largest for small fields and high beam energy, at the surface, reaching a maximum

  20. The biological bases of the dose-effect relationship; Les bases biologiques de la relation dose-effet

    Energy Technology Data Exchange (ETDEWEB)

    Lafuma, J

    2001-06-01

    In radiation protection, the recent data in epidemiology, in animal experimentation and on the base researches are no more compatible with a linear dose-effect relationship without threshold and do not account for the radiological risks at low doses. The cancers should be accelerated by radiations as any pathology linked to the ageing and for which threshold exit. Relative to the genetic risk it is known today that the natural exposure that lasts for several generations has not lead excess of hereditary illness as it was to be feared in 1959 for several countries. Considering that for populations the exposure levels induced by human activities have already been, under these ones of average natural exposures the genetic risk can be negligible and it is the somatic risk alone, with its thresholds that has to be into account. (N.C.)

  1. Changes in pulmonary function and influencing factors after high-dose intrathoracic radio(chemo)therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Christina [University Clinic Giessen and Marburg, Clinic for Radiotherapy and Radiation Oncology, Marburg (Germany); Ruppiner Kliniken GmbH, Clinic for Radiotherapy and Radiation Oncology, Neuruppin (Germany); Engenhart-Cabillic, Rita; Vorwerk, Hilke [University Clinic Giessen and Marburg, Clinic for Radiotherapy and Radiation Oncology, Marburg (Germany); Schmidt, Michael; Huhnt, Winfried; Blank, Eyck; Sidow, Dietrich; Buchali, Andre [Ruppiner Kliniken GmbH, Clinic for Radiotherapy and Radiation Oncology, Neuruppin (Germany)

    2017-02-15

    Using prospectively collected patient-related, dose-related, and pulmonary function test (PFT) data before radiotherapy (RT) and at several follow-up visits after RT, the time course of PFT changes after high-dose radio(chemo)therapy and influencing factors were analyzed. From April 2012 to October 2015, 81 patients with non-small-cell lung carcinoma (NSCLC), small cell lung carcinoma (SCLC), or esophageal carcinoma where treated with high-dose radio(chemo)therapy. PFT data were collected before treatment and 6 weeks, 12 weeks, and 6 months after RT. The influence of patient- and treatment-related factors on PFT was analyzed. Mean forced expiratory volume in 1 s (FEV1) constantly declined during follow-up (p = 0.001). In total, 68% of patients had a reduced FEV1 at 6 months. Mean vital capacity (VC) didn't change during follow-up (p > 0.05). Mean total lung capacity (TLC) showed a constant decline after RT (p = 0.026). At 6 months, 60% of patients showed a decline in VC and 73% in TLC. The mean diffusion capacity for carbon monoxide (DLCO) declined at 6 and 12 weeks, but recovered slightly at 6 months (p < 0.0005). At 6 months, 86% of patients had a reduced DLCO. After treatment, the partial pressure of CO{sub 2} in the blood (pCO{sub 2}) was increased and pO{sub 2} was decreased (p > 0.05). Only the pretreatment PFT classification had a significant influence on the post-RT FEV1. DLCO seems to be the most reliable indicator for lung tissue damage after thoracic RT. Ventilation parameters appear to be less reliable. Concerning patient- or treatment-related factors, no reliable conclusion can be drawn regarding which factors may be relevant. (orig.) [German] Patientenbezogene, therapiebezogene und Lungenfunktionsdaten (''pulmonary function test'', PFT) wurden vor Radiotherapie (RT) und an verschiedenen Nachsorgeterminen nach RT prospektiv gesammelt, um PFT-Veraenderungen sowie Einflussfaktoren nach Hochdosis-Radio(chemo)therapie zu

  2. Development of a correction factor for Xe-133 vials for use with a dose calibrator

    International Nuclear Information System (INIS)

    Gels, G.L.; Piltingsrud, H.V.

    1982-01-01

    Manufacturers of dose calibrators who give calibration settings for various radionuclies sometimes do not specify the type of radionuclide container the calibration is for. The container, moreover, may not be of the same type as those a user might purchase. When these factors are not considered, the activity administered to the patient may be significantly different from that intended. An experiment is described in which calibration factors are determined for measurement of Xe-133 activity in vials in a dose calibrator. This was accomplished by transferring the Xe-133 from the commercial vials to standard NBS calibration ampules. Based on ten such transfers, the resulting correction factor for the dose calibrator was 1.22

  3. Age-specific inhalation radiation dose commitment factors for selected radionuclides

    International Nuclear Information System (INIS)

    Strenge, D.L.; Peloquin, R.A.; Baker, D.A.

    1982-08-01

    Inhalation dose commitment factors are presented for selected radionuclides for exposure of individuals in four age groups: infant, child, teen and adult. Radionuclides considered are 35 S, 36 Cl, 45 Ca, 67 Ga, 75 Se, 85 Sr, 109 Cd, 113 Sn, 125 I, 133 Ba, 170 Tm, 169 Yb, 182 Ta, 192 Ir, 198 Au, 201 Tl, 204 Tl, and 236 Pu. The calculational method is based on the human metabolic model of ICRP as defined in Publication 2 (ICRP 1959) and as used in previous age-specific dose factor calculations by Hoenes and Soldat (1977). Dose commitment factors are presented for the following organs of reference: total body, bone, liver, kidney, thyroid, lung and lower large intestine

  4. Dose-response relations for stricture in the proximal oesophagus from head and neck radiotherapy

    International Nuclear Information System (INIS)

    Alevronta, Eleftheria; Ahlberg, Alexander; Mavroidis, Panayiotis; Al-Abany, Massoud; Friesland, Signe; Tilikidis, Aris; Laurell, Goeran; Lind, Bengt K.

    2010-01-01

    Background and purpose: Determination of the dose-response relations for oesophageal stricture after radiotherapy of the head and neck. Material and methods: In this study 33 patients who developed oesophageal stricture and 39 patients as controls are included. The patients received radiation therapy for head and neck cancer at Karolinska University Hospital, Stockholm, Sweden. For each patient the 3D dose distribution delivered to the upper 5 cm of the oesophagus was analysed. The analysis was conducted for two periods, 1992-2000 and 2001-2005, due to the different irradiation techniques used. The fitting has been done using the relative seriality model. Results: For the treatment period 1992-2005, the mean doses were 49.8 and 33.4 Gy, respectively, for the cases and the controls. For the period 1992-2000, the mean doses for the cases and the controls were 49.9 and 45.9 Gy and for the period 2001-2005 were 49.8 and 21.4 Gy. For the period 2001-2005 the best estimates of the dose-response parameters are D 50 = 61.5 Gy (52.9-84.9 Gy), γ = 1.4 (0.8-2.6) and s = 0.1 (0.01-0.3). Conclusions: Radiation-induced strictures were found to have a dose response relation and volume dependence (low relative seriality) for the treatment period 2001-2005. However, no dose response relation was found for the complete material.

  5. Calculation of neutron and gamma-ray flux-to-dose-rate conversion factors

    International Nuclear Information System (INIS)

    Kwon, S.G.; Lee, S.Y.; Yook, C.C.

    1981-01-01

    This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute (ANSI) N666. These data are used to calculate the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoenergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions. (author)

  6. Does a dose-response relation exist between spinal pain and temporomandibular disorders?

    Directory of Open Access Journals (Sweden)

    Englund Erling

    2009-03-01

    Full Text Available Abstract Background The aim of this study was to test whether a reciprocal dose-response relation exists between frequency/severity of spinal pain and temporomandibular disorders (TMD. Methods A total of 616 subjects with varying severity of spinal pain or no spinal pain completed a questionnaire focusing on symptoms in the jaw, head and spinal region. A subset of the population (n = 266 were sampled regardless of presence or absence of spinal pain. We used two different designs, one with frequency/severity of spinal pain, and the other, with frequency/severity of TMD symptoms as independent variable. All 616 participants were allocated to four groups, one control group without spinal pain and three spinal pain groups. The subjects in the subset were allocated to one control group without TMD symptoms and three TMD groups. Odds ratios (ORs were calculated for presence of frequent TMD symptoms in the separate spinal pain groups as well as for frequent spinal pain in the separate TMD groups. Results The analysis showed increasing ORs for TMD with increasing frequency/severity of spinal pain. We also found increasing ORs for spinal pain with increasing frequency/severity of TMD symptoms. Conclusion This study shows a reciprocal dose-response-like relationship between spinal pain and TMD. The results indicate that these two conditions may share common risk factors or that they may influence each other. Studies on the temporal sequence between spinal pain and TMD are warranted.

  7. Application of the dose conversion factor for a NaI(Tl) detector to the radwaste drum assay

    International Nuclear Information System (INIS)

    Ji, Young-Yong; Hong, Dae-Seok; Kim, Tae-Kuk; Kwak, Kyung-Kil; Ryu, Woo-Seog

    2011-01-01

    The dose-to-curie (DTC) conversion method has been known that there could be extremely high uncertainty associated with establishing the radioactivity of gamma emitters in a drum. However, the DTC conversion method is still an effective assay method to calculate the radioisotope inventory because of the simple and easy procedures to be applied. In order to make the DTC conversion method practical, numerous assumptions and limitations placed on its use. These assumptions and limitations are related to the dose rate measurement and the relative abundance of gamma emitters in a drum. However, these two variables were generally obtained from the different detection mechanisms even using the different radwaste each other. Unfortunately, that expanded the limitation of using the DTC conversion method. In order to obtain two variables in a drum to be assayed at once, the dose conversion factor for a NaI(Tl) detector was first calculated from the MCNP code. The pulse height spectrum from a simulated drum inserted into a standard source was measured by a NaI(Tl) detector, and then, two variables were calculated from the dose conversion factor and the net count rate of detected gamma emitters in the pulse height spectrum.

  8. Neutron fluence-to-dose equivalent conversion factors: a comparison of data sets and interpolation methods

    International Nuclear Information System (INIS)

    Sims, C.S.; Killough, G.G.

    1983-01-01

    Various segments of the health physics community advocate the use of different sets of neutron fluence-to-dose equivalent conversion factors as a function of energy and different methods of interpolation between discrete points in those data sets. The major data sets and interpolation methods are used to calculate the spectrum average fluence-to-dose equivalent conversion factors for five spectra associated with the various shielded conditions of the Health Physics Research Reactor. The results obtained by use of the different data sets and interpolation methods are compared and discussed. (author)

  9. Talking about relations: Factors influencing the production of relational descriptions

    Directory of Open Access Journals (Sweden)

    Adriana eBaltaretu

    2016-02-01

    Full Text Available In a production experiment (Experiment 1 and an acceptability rating one (Experiment 2, we assessed two factors, spatial position and salience, which may influence the production of relational descriptions (such as the ball between the man and the drawer. In Experiment 1, speakers were asked to refer unambiguously to a target object (a ball. In Experiment 1a, we addressed the role of spatial position, more specifically if speakers mention the entity positioned leftmost in the scene as (first relatum. The results showed a preference to start with the left entity, however, only as a trend, which leaves room for other factors that could influence spatial reference. Thus, in the following studies, we varied salience systematically, by making one of the relatum candidates animate (Experiment 1b, and by adding attention capture cues, first subliminally by priming one relatum candidate with a flash (Experiment 1c, then explicitly by using salient colors for objects (Experiment 1d. Results indicate that spatial position played a dominant role. Entities on the left were mentioned more often as (first relatum than those on the right (Experiment 1a, 1b, 1c, 1d. Animacy affected reference production in one out of three studies (in Experiment 1d. When salience was manipulated by priming visual attention or by using salient colors, there were no significant effects (Experiment 1c, 1d. In the acceptability rating study (Experiment 2, participants expressed their preference for specific relata, by ranking descriptions on the basis of how good they thought the descriptions fitted the scene. Results show that participants preferred most the description that had an animate entity as the first mentioned relatum. The relevance of these results for models of reference production is discussed.

  10. Evaluation of fading factor and self-dose for glass dosimeter and thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Yamasaki, T.; Yamanishi, H.; Miyake, H.; Komura, K.

    2000-01-01

    The glass dosimeter (GD) and thermoluminescence dosimeter (TLD) are both passive radiation detectors. They are often used for measuring environmental radiation. In order to measure low dose rate preciously, it is important to evaluate decreased dose due to fading and self-dose during the exposure period. We evaluate the fading factor and self-dose of thee passive detectors, GD and TLD. We select Ogoya tunnel for the experiment. The tunnel is suitable field for measuring faded dose and self-dose because it is low cosmic radiation. At the center of the tunnel, the intensity of cosmic ray is reduced to about 1/177 than the outside of the funnel. We prepared two sets of dosimeters. One set consists of five GDs, five TLDs and some pre-irradiated GDs and TLDs that are exposed to standard radiation of 4 mGy by Cs-137. These dosimeters are put in the 10 cm thick lead box in order to shield the terrestrial gamma ray. One set is located at the center of the tunnel and the other is the outside of the funnel. The dosimeters were exposed for ten months, from May 1998 to March 1999. After the exposure, the readers of dosimeters are carried into the funnel to read out the signals promptly as soon as taking out the dosimeters. As a result of the measurement, four kinds of data are taken for GD and TLD respectively. Assumed that the self-dose and cosmic ray are constant during exposure, the four independent unknown quantities, a self-dose a dose due to cosmic ray and a fading coefficient at the center of the tunnel and at the outside, are considered. Therefore four simultaneous equations should be obtained. From these examinations, the faded dose of GD is less than 1%, but that of TLD is about 16% during ten months. The coefficient for compensation of fading of GD and TLD is given as the half of the each value. At the outside of the tunnel, the measured dose rate of cosmic ray that can pass through the 10 cm lead is evaluated to be about 16 nGy/h by both detectors. The self-dose

  11. T3 glottic cancer: an analysis of dose time-volume factors

    International Nuclear Information System (INIS)

    Harwood, A.R.; Beale, F.A.; Cummings, B.J.; Hawkins, N.V.; Keane, T.J.; Rider, W.D.

    1980-01-01

    This report analyzes dose-time-volume factors in 112 patients with T3N0M0 glottic cancer who were treated with radical radiotherapy with surgery for salvage between 1963 and 1977. 55% of the patients are alive and well 5 years following treatment; 26% died of glottic cancer and 19% died of intercurrent disease. In the 1965 to 1969 time period, 31% died of tumor as compared to 16% in the 1975 to 1977 time period. Overall local control by radiotherapy was 51%; 2/3 of the failures were surgically salvaged. 44% were locally controlled by radiotherapy in the 1965 to 1969 time period and 57% in the 1975 to 1977 time period. Analysis of dose-time-volume factors reveals that the optimal dose is greater than 1700 ret and a minimal volume of 6 x 8 cm should be used. A dose-cure curve for T3 glottic cancer is constructed and compared with the dose complication curve for the larynx and the dose-cure curve for T1N0M0 glottic cancer. A comparison of cure rates between 112 patients treated with radical radiotherapy and surgery for salvage versus 28 patients treated with combined pre-operative irradiation and surgery reveals no difference in the proportion of patients who died of glottic cancer or in the number of patients alive at 5 years following treatment

  12. High-dose ascorbic acid decreases cholesterolemic factors of an atherogenic diet in guinea pigs.

    Science.gov (United States)

    Filis, Konstantinos; Anastassopoulou, Aikaterini; Sigala, Fragiska; Theodorou, Dimitrios; Manouras, Andreas; Leandros, Emanouel; Sigalas, Panagiotis; Hepp, Wolfgang; Bramis, John

    2007-03-01

    The study evaluates the effect of a high supplemental dose of ascorbic acid (AA) on plasma concentrations of total cholesterol (TC), triglycerides (TG), total lipids (TL), and lipoprotein fractions high-density, very-low-density-, and low-density lipoprotein (HDL, VLDL, LDL) in guinea pigs fed with atherogenic diet. Group I consisted of 5 normally fed guinea pigs plus a low dose of AA (1 mg/100 g/day), group II consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a low dose of AA (1 mg/100 g/day), and group III consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a high dose of AA (30 mg/100 g/day). Cholesterolemic factors concentrations were determined after nine weeks. Concentrations of TC, TG, TL, LDL, and VLDL were increased in group II compared to group I (p < 0.01 for all differences). Supplementation with a high dose of AA resulted in decreased concentrations of TC (p < 0.01), TG (p < 0.01), TL (p < 0.01), and LDL (p < 0.01) in group III compared to group II. Additionally, concentration of HDL was increased in group III compared to group II (p < 0.01). High-dose AA supplementation to an atherogenic diet decreases concentrations of TC, TG, TL, and LDL and increases concentration of HDL compared to low-dose AA.

  13. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  14. Risk Factors and Dose-Effect Relationship for Mandibular Osteoradionecrosis in Oral and Oropharyngeal Cancer Patients

    International Nuclear Information System (INIS)

    Lee, Ik Jae; Koom, Woong Sub; Lee, Chang Geol; Kim, Yong Bae; Yoo, Sei Whan; Keum, Ki Chang; Kim, Gwi Eon; Choi, Eun Chang; Cha, In Ho

    2009-01-01

    Purpose: To analyze risk factors and the dose-effect relationship for osteoradionecrosis (ORN) of the mandible after radiotherapy of oral and oropharyngeal cancers. Materials and Methods: One-hundred ninety-eight patients with oral (45%) and oropharyngeal cancer (55%) who had received external radiotherapy between 1990 and 2000 were retrospectively reviewed. All patients had a dental evaluation before radiotherapy. The median radiation dose was 60 Gy (range, 16-75 Gy), and the median biologically effective dose for late effects (BED late ) in bone was 114 Gy 2 (range, 30-167 Gy 2 ). Results: The frequency of ORN was 13 patients (6.6%). Among patients with mandibular surgery, eight had ORN at the surgical site. Among patients without mandibular surgery, five patients had ORN on the molar area of the mandible. The median time to ORN was 22 months (range, 1-69 months). Univariate analysis revealed that mandibular surgery and Co-60 were significant risk factors for ORN (p = 0.01 and 0.04, respectively). In multivariate analysis, mandibular surgery was the most important factor (p = 0.001). High radiation doses over BED 102.6 Gy 2 (conventional dose of 54 Gy at 1.8 Gy/fraction) were also a significant factor for ORN (p = 0.008) and showed a positive dose-effect relationship in logistic regression (p = 0.04) for patients who had undergone mandibular surgery. Conclusions: Mandibular surgery was the most significant risk factor for ORN of mandible in oral and oropharyngeal cancers patients. A BED of 102.6 Gy 2 or higher to the mandible also significantly increases the risk of ORN.

  15. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses

    International Nuclear Information System (INIS)

    Huda, Walter; Lieberman, Kristin A.; Chang, Jack; Roskopf, Marsha L.

    2004-01-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18x7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186±8 mm and 147±8 mm, respectively, with an average HU value of 209±40. An infant head was found to be equivalent to a water cylinder with a radius of ∼60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is ∼20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors

  16. Psychological Factors related to traffic accidents

    Directory of Open Access Journals (Sweden)

    Serafín Aldea Muñoz

    2002-07-01

    Full Text Available Automobile drivers fine themselves affected by series psychological factors which are directly related to traffic accidents. In this study we intend to investigate these variables, basing our work on the most convenient sources of information, coming from the police, the General Direction of Traffic, the courts, insurance companies, the Red Cross, Social Security, and forensics. Neither could we ignore the influence which certain forces hold over people´s mental health; this can sometimes intensely affect how they drive. In fact, in the most diverse situations we can observe the way in which a person carries out a task can be conditioned by the presence of other person who may have no direct relationship to him. Society has established its limitations and rules, but speed itself feels omnipotence when imposing controls over the most profound behavior in others; man in usually not conscious of these controls. People generally drive their automobiles in a way similar to their habitual behavior and their personality traits. Nevertheless, it is also important to consider the adaptation of their way of driving to their state of mind at any given moment. The majority of subjects tend to adapt their driving to their emotional state.

  17. A nested case-control approach to interactions between radiation dose and other factors as causes of cancer

    Energy Technology Data Exchange (ETDEWEB)

    Land, Charles E [Department of Epidemiology, Radiation Epidemiology Branch, US National Cancer Institute, Bethesda, MD (United States)

    1992-04-01

    Often a nested case-control study is the most practicable approach to estimating the interaction of two cancer risk factors in a large cohort. If one of the factors has already been evaluated for the entire cohort, however, more information is already available about its relationship to risk than could be obtained from a nested study. A modified case-control approach is proposed, in which information about the second, unknown factor is sought for cases and controls matched on the first factor. The approach requires, for interaction models other than the multiplicative, a nonstandard analytical approach incorporating cohort-based information about the first factor. The problem is discussed in the context of breast cancer risk in a defined cohort of female Japanese atomic bomb survivors, in relation to radiation dose and reproductive history. (author)

  18. Task related doses in Spanish pressurized water reactors over the period 1988-1992

    Energy Technology Data Exchange (ETDEWEB)

    O`Donnell, P.; Labarta, T.; Amor, I. [Subdireccion de Proteccion Radiologica, Madrid (Spain)

    1995-03-01

    In order to evaluate in depth the collective dose trend and its correlation with the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities, and base the different policy lines to promote this criteria, the CSN has fullfilled an analysis of the task related doses data over the period 1988-1992. Previously, the CSN had required to the utilities the compilation of their refuelling outage collective dose from 1988 according with a predeterminate number of tasks, in order to have available a representative and retrospective set of data in an homogeneous way and coherent with the international data banks on occupational exposure in NPP, as the CEC and the NEA ones. The scope of this analysis was the following: first, the collective dose summaries for outage tasks and departments for PWR and for BWR, including the minimum, maximum and average dose (and statistics data) for 18 different refuelling outage tasks and 12 personal departments for each generation of each type of rector, the task and department related collective dose trends in each plant and in each generation, and second, the dose reduction techniques having been used during that period in each plant and the relative level of adoption. In this presentation the main results and conclusions of the first part of the study are reviewed for PWR.

  19. Definition of dose intensity (DI), average relative DI and effective DI

    International Nuclear Information System (INIS)

    Alberto, P.

    1995-01-01

    The cytotoxic activity of cancer chemotherapy is related to the dose and to the amount of drug delivered per time unit. the significance of time in the effectiveness of a treatment program is frequently overlooked. The term of dose intensity (DI) is used to define the drug dose delivered per time unit and is expressed as mg/m 2 per week. A delay in the sequence of treatment cycles decreases the DI in the DI in the same proportion as a reduction of dose. Average relative DI corresponds to the mean DI of combined agents and is expressed as a fraction of a similar combination selected as a standard. Di is useful to compare the dose actually received with the prescribed dose. The relation of DI with tumor response or survival has not been fully demonstrated. A threshold DI level for therapeutic activity is evident. Above this threshold, a linear relationship of DI and effectiveness is not obvious, particularly regarding high-dose chemotherapy. The term of DI is more useful in its principle than in the significance of its calculated value. (authors). 19 refs., 3 tabs., 3 figs

  20. Standardized dose factors for dose calculations - 1982 SRP reactor safety analysis report tritium, iodine, and noble gases

    International Nuclear Information System (INIS)

    Pillinger, W.L.; Marter, W.L.

    1982-01-01

    Standardized dose constants are recommended for calculation of offsite doses in the 1982 SRP Reactor Safety Analysis Report (SAR). Dose constants are proposed for inhalation of tritium and radioiodines and for submersion in a semi-infinite cloud of radioiodines and noble gases. The proposed constants, based on ICRP2 methodology for internal dose and methodology recommended by the US Nuclear Regulatory Commission for external dose, are compatible with dose calculational methods used at the Savannah River Plant and Savannah River Laboratory for normal releases of radioactivity. 8 references

  1. A simple method for estimating the effective dose in dental CT. Conversion factors and calculation for a clinical low-dose protocol

    International Nuclear Information System (INIS)

    Homolka, P.; Kudler, H.; Nowotny, R.; Gahleitner, A.; Wien Univ.

    2001-01-01

    An easily appliable method to estimate effective dose including in its definition the high radio-sensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. Methods: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. Results: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 μSv can be achieved, which compares to values typically obtained with panoramic radiography (26 μSv). A CT scan of the mandible, respectively, gives 123 μSv comparable to a full mouth survey with intraoral films (150 μSv). Conclusion: For standard CT scan protocols of the mandible, effective doses exceed 600 μSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate. (orig.) [de

  2. Determination of key radionuclides and parameters related to dose from the Columbia River pathway

    International Nuclear Information System (INIS)

    Napier, B.A.

    1993-03-01

    A series of scoping calculations has been undertaken to evaluate the absolute and relative contributions of different radionuclides and exposure pathways to doses that may have been received by individuals living in the vicinity of the Hanford Site. These scoping calculations may include some radionuclides and pathways that were included in the Phase 1 Columbia River pathway dose evaluations, as well as other potential exposure pathways being evaluated for possible inclusion in future Hanford Environmental Dose Reconstruction Project (HEDR) modeling efforts. This scoping calculation (Calculation 009) examines the contributions of numerous radionuclides to dose via environmental exposures and accumulation in water, fish, and other aquatic biota. Addressed in these calculations are the contributions to effective dose from (1) external exposure to contaminated river water, ( 2) ingestion of contaminated drinking water, and (3) ingestion of contaminated resident Columbia River fish. Additional information on contamination of anadromous fish and waterfowl is provided

  3. Environmental factors used for the estimation of radiation dose to thyroid gland

    International Nuclear Information System (INIS)

    Ohmomo, Yoichiro

    1976-01-01

    Environmental factors used for the estimation of radiation dose to thyroid gland were discussed in this paper, such as deposition velocity of radioactive iodine onto plant leaves, elimination factor from the leaves, transfer of this nuclide to milk and the consumption of those critical foods especially by inhabitants around nuclear sites in coastal area of Ibaraki Prefecture. Uptake of the stable iodine was estimated. (auth.)

  4. Uncertainties in the correction factors as the dose polarization and recombination at different energies

    International Nuclear Information System (INIS)

    Alejo Luque, L.; Rodriguez Romero, R.; Castro Tejero, P.; Fandino Lareo, J. M.

    2011-01-01

    This paper discusses the measures and uncertainties of the correction factors for dose-polarization (k, 1) and recombination (k,) of different ionization chambers plane-parallel and cylindrical. The values ??have been obtained using photon and electron beams of various energies generated by linear accelerators nominal Varian 21EX CLJNAC Tomotherapy Hi-Art and JI. We study the cases in which you can avoid the application of the factors obtained, according to the criteria proposed

  5. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  6. Outdoor γ-ray dose rate in Shariki Village and environmental factors affecting outdoor γ-ray dose rate in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2000-01-01

    Previously, we surveyed the outdoor γ-ray dose rate throughout Aomori Prefecture from 1992 to 1995, and found an annual mean dose rate of 51 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Shariki Village. Glass dosemeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the village. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosemeters showed that the γ-ray dose rates in Shariki Village varied from 49 to 55 nGy h -1 . Although the dose rates were generally higher than the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the village. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in the IES site. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 27 nGy h -1 and higher than when no precipitation was sensed (25 nGy h -1 ). (author)

  7. Outdoor γ-ray dose rate in Mutsu city and environmental factors affecting outdoor γ-ray dose rate in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2001-01-01

    Previously, we surveyed outdoor γ-ray dose rates throughout Aomori Prefecture from 1992 to 1995, and found a mean annual dose rate of 28 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Mutsu City. Glass dosemeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the city. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosemeters showed that the γ-ray dose rates in Mutsu City varied from 17 to 32 nGy h -1 . Although the dose rates were almost the same as the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the local ground. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in the IES site. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 26 nGy h -1 and higher than when no precipitation was sensed (24 nGy h -1 ). (author)

  8. Relative biological effectiveness and radiation weighting factors in the context of animals and plants

    International Nuclear Information System (INIS)

    Higley, K.A.; Kocher, D.C.; Real, A.G.; Chambers, D.B.

    2012-01-01

    Radiation weighting factors have long been employed to modify absorbed dose as part of the process of evaluating radiological impact to humans. Their use represents an acknowledgement of the fundamental difference in energy deposition patterns of charged and uncharged particles, and how this can translate into varying degrees of biological impact. Weighting factors used in human radiation protection are derived from a variety of endpoints taken from in-vitro experiments that include human and animal cell lines, as well as in-vivo experiments with animals. Nonetheless, the application of radiation weighting factors in the context of dose assessment of animals and plants is not without some controversy. Specifically, radiation protection of biota has largely focused on limiting deterministic effects, such as reduced reproductive fitness. Consequently, the application of conventional stochastic-based radiation weighting factors (when used for human protection) appears inappropriate. While based on research, radiation weighting factors represent the parsing of extensive laboratory studies on relative biological effectiveness. These studies demonstrate that the magnitude of a biological effect depends not just on dose, but also on other factors including the rate at which the dose is delivered, the type and energy of the radiation delivering the dose, and, most importantly, the endpoint under consideration. This article discusses the efforts taken to develop a logical, transparent, and defensible approach to establishing radiation weighting factors for use in assessing impact to non-human biota, and the challenges found in differentiating stochastic from deterministic impacts.

  9. Dose-modifying factors for skin ulceration in mouse legs exposed to gamma rays

    International Nuclear Information System (INIS)

    Masuda, Kouji; Miyoshi, Makoto; Uehara, Satoru; Omagari, Junichi; Withers, H.R.

    1996-01-01

    To assess the dose-modifying factors for skin ulceration, the hind legs of mice were irradiated using gamma-rays of various doses in single exposures. The skin ulceration began to occur 2 months after irradiation, after early skin reactions such as wet desquamation, had healed completely. No new skin ulceration was observed more than 8 months after irradiation even though the observations were continued until 12 months post-irradiation. The ulceration dose 50 (UD50), a dose required to produce skin ulceration in from 2 to 8 months in 50% of the tested animals, was calculated for each treatment schedule. The preliminary shaving procedure reduced the UD50 dose to 0.85 that of the untreated controls. The ventral aspect of the hind leg was more radioresistant to single-dose irradiation than was to the dorsal aspect. The UD50 for the ventral aspect was 1.29 times that for the dorsal aspect when the skin had been previously shaved, and 1.46 times that for the unshaved control legs. The UD50 was 7 and 14% larger when mice were kept in the dorsal rather than the abdominal position during irradiation, for the preliminarily shaved and unshaved skin, respectively. (author)

  10. Changes of indoor aerosol characteristics and their associated variation on the dose conversion factor due to radon progeny inhalation

    International Nuclear Information System (INIS)

    Tokonami, Shinji; Ishikawa, Tetsuo; Yonehara, Hidenori; Yamada, Yuji; Matsuzawa, Takao; Iimoto, Takeshi

    2003-01-01

    Since the dose conversion factor (hereafter called DCF) due to radon progeny inhalation is strongly dominated by aerosol characteristics in the environment, it is important to understand the air quality for accurate dose assessment. Thus temporal variations on aerosol concentration, its particle size and its related airborne radioactivities were continuously measured in an actual indoor environment with a relatively high radon concentration. The following human activities were added during the observation period: air-conditioning, removal of aerosol with an air cleaner and ventilation. DCFs based on these activities were evaluated with the latest International Commission of Radiological Protection (ICRP) respiratory tract model and were compared among them. Consequently, the present study has shown that operation of air cleaner enhanced the DCF critically because the unattached fraction increased significantly due to removal of aerosols. (author)

  11. An engagement factor for caregiver radiation dose assessment with radioiodine treatment

    International Nuclear Information System (INIS)

    Lee, Hyun Kuk; Hong, Seong Jong; Jeong, Kyu Hwan; Jung, Jae Won; Kim, Seong Min; Kang, Yun-Hee; Han, Man Seok

    2015-01-01

    This study aims to suggest ways to better manage thyroid cancer patients treated with high- and low-activity radioiodine ( 131 I) by assessing external radiation doses to family members and caregivers and the level of radiation in the surrounding environment. The radiation doses to caregivers of 33 inpatients (who were quarantined in the hospital for 2-3 d after treatment) and 31 outpatients who received radioiodine treatment after thyroidectomy were measured using passive thermoluminescence dosemeters. In this study, 33 inpatients were administered high-activity (100-200 mCi) 131 I, and 31 outpatients were administered low-activity (30 mCi) 131 I. The average doses to caregivers were measured at 0.61 mSv for outpatients and 0.16 mSv for inpatients. The total integrated dose of the recovery (recuperation) rooms where the patients stayed after release from hospital was measured to be 0.83 mSv for outpatients and 0.23 mSv for inpatients. To reflect the degree of engagement between the caregiver and the patient, considering the duration and distance between two during exposure, the authors used the engagement factor introduced by Jeong et al. (Estimation of external radiation dose to caregivers of patients treated with radioiodine after thyroidectomy. Health Phys 2014;106:466-474.). This study presents a new engagement factor (K-value) of 0.82 obtained from the radiation doses to caregivers of both in- and out-patients treated with high- and low-activity radioiodine, and based on this new value, this study presented a new predicted dose for caregivers. A patient treated with high-activity radioiodine can be released after 24 h of isolation, whereas outpatients treated with low-activity radioiodine should be isolated for at least 12 h. (authors)

  12. Interpretation of proton relative biological effectiveness using lesion induction, lesion repair, and cellular dose distribution

    International Nuclear Information System (INIS)

    Paganetti, H.

    2005-01-01

    Phenomenological biophysical models have been successfully used to estimate the relative biological effectiveness (RBE) of ions. The predictive power of these models is limited because they require measured dose-response data that are not necessarily available for all clinically relevant end points. Furthermore, input parameters often lack mechanistic interpretation. In order to link RBE to more fundamental biological parameters we combine the concepts of two well-established biophysical models, i.e., the phenomenological 'track structure' model and the more mechanistic 'lethal lesion/potentially lethal lesion' (LPL) model. We parametrize a relation between RBE, dose homogeneity in the cell nucleus and induction rates for different lesion types. The macroscopic dose-response relationship is described in the LPL model and the microscopic, subcellular, relationship is determined by the local dose deposition pattern. The formalism provides a framework for a mechanistic interpretation of RBE values

  13. Task related doses in spanish light water reactors over the period 1990-1996

    International Nuclear Information System (INIS)

    Aroca, J.; Montesinos, J.J.; O'Donnell, P.; Amor, I.; Butragueno, J.L.

    1998-01-01

    In order to evaluate in depth the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities -7 PWR (6 Westinghouse and 1 KWU-Siemens) and 2 BWR (Generic Electric), and to have a further overview of dose trends, the CSN has analysed the task related doses data over the period 1990-1996. The scope of this analysis includes the collective dose and relative relevance for 18 different refuelling outage tasks, some sub-tasks, 12 department staff, and the main consolidated dose reduction-techniques and good practices. Data has been collected from the outage reports NPPs provide according to the CSN 1.5 Safety Guide format. (Author)

  14. Absorbed dose calibration factors for parallel-plate chambers in high energy photon beams

    International Nuclear Information System (INIS)

    McEwen, M.R.; Duane, S.; Thomas, R.A.S.

    2002-01-01

    parallel-plate chambers, which is discussed below. The small difference (around 0.3%) between the NACP and Roos chambers at the highest photon energies is within the measurement uncertainties but may indicate a slight difference in chamber response. A number of chambers were recalibrated six months later to investigate chamber stability. It was found that the repeatability was generally better than 0.5% and the variations in time appear to be random. These differences are larger than for thimble chambers, where we have found stability at better than the 0.3% level over several years. Parallel-plate chambers in electron beams have also showed high stability (McEwen et al, 2001), which would indicate that parallel-plate chambers are sensitive to small variations in the beam quality of photon beams that do not affect thimble chambers. This data can also be used to derive relative wall correction factors for the Roos and NACP. Good agreement (within 0.3%) was found with previous data (Palm et al, 2000; Nystrom et al, 1993). These measurements would seem to confirm that p wall for the Roos chamber given in TRS-381 is too low by around 0.5%. Parallel-plate chambers can be calibrated in terms of absorbed dose to water, but with an uncertainty larger than for thimble chambers. Chamber stability also appears to be worse than for thimble chambers. Polarity corrections must always be measured and applied, as the polarity effect for a particular chamber is difficult to predict

  15. Dose-Volume Histogram Parameters and Clinical Factors Associated With Pleural Effusion After Chemoradiotherapy in Esophageal Cancer Patients

    International Nuclear Information System (INIS)

    Shirai, Katsuyuki; Tamaki, Yoshio; Kitamoto, Yoshizumi; Murata, Kazutoshi; Satoh, Yumi; Higuchi, Keiko; Nonaka, Tetsuo; Ishikawa, Hitoshi; Katoh, Hiroyuki; Takahashi, Takeo; Nakano, Takashi

    2011-01-01

    Purpose: To investigate the dose-volume histogram parameters and clinical factors as predictors of pleural effusion in esophageal cancer patients treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Forty-three esophageal cancer patients treated with definitive CRT from January 2001 to March 2007 were reviewed retrospectively on the basis of the following criteria: pathologically confirmed esophageal cancer, available computed tomography scan for treatment planning, 6-month follow-up after CRT, and radiation dose ≥50 Gy. Exclusion criteria were lung metastasis, malignant pleural effusion, and surgery. Mean heart dose, mean total lung dose, and percentages of heart or total lung volume receiving ≥10-60 Gy (Heart-V 10 to V 60 and Lung-V 10 to V 60 , respectively) were analyzed in relation to pleural effusion. Results: The median follow-up time was 26.9 months (range, 6.7-70.2) after CRT. Of the 43 patients, 15 (35%) developed pleural effusion. By univariate analysis, mean heart dose, Heart-V 10 to V 60 , and Lung-V 50 to V 60 were significantly associated with pleural effusion. Poor performance status, primary tumor of the distal esophagus, and age ≥65 years were significantly related with pleural effusion. Multivariate analysis identified Heart-V 50 as the strongest predictive factor for pleural effusion (p = 0.01). Patients with Heart-V 50 50 50 ≥40% had 6%, 44%, and 64% of pleural effusion, respectively (p 50 is a useful parameter for assessing the risk of pleural effusion and should be reduced to avoid pleural effusion.

  16. Comparison between apparent viscosity related to irradiation dose for corn starch and black pepper

    International Nuclear Information System (INIS)

    Casandroiu, T.; Oprita, N.; Ferdes, O.S.

    1999-01-01

    Dose-effect relationship was studied in the rheoviscometric behaviour of geliffied suspensions of irradiated corn starch and black pepper, as the variation of the apparent viscosity and the shear stress related to the dose. Irradiation has been performed up to 16 kGy. Black pepper was ground and sieved to three particle sizes to analyse also the influence of particle size on the apparent viscosity variation by dose. The rheoviscometric measurements have been carried out by a rotationary viscometer on geliffied suspensions of starch and black pepper, into equivalent starch concentration and alkalinised suspensions for pepper. For starch, shear stress variation by dose is exponential, where the coefficients depend on the shear rate. For black pepper, the curves of apparent viscosity relation to dose also fit an exponential equation and the influence of particle size is discussed, too. Viscometric behaviour similar to irradiation of both corn starch and black pepper could be attributed to starch degradation at relatively high doses and should be used to develop an identification and control method for the ionizing treatment of starch-based food materials. (author)

  17. Factors influencing completion of multi-dose vaccine schedules in adolescents: a systematic review

    Directory of Open Access Journals (Sweden)

    K. E. Gallagher

    2016-02-01

    Full Text Available Abstract Background Completion of multiple dose vaccine schedules is crucial to ensure a protective immune response, and maximise vaccine cost-effectiveness. While barriers and facilitators to vaccine uptake have recently been reviewed, there is no comprehensive review of factors influencing subsequent adherence or completion, which is key to achieving vaccine effectiveness. This study identifies and summarises the literature on factors affecting completion of multi-dose vaccine schedules by adolescents. Methods Ten online databases and four websites were searched (February 2014. Studies with analysis of factors predicting completion of multi-dose vaccines were included. Study participants within 9–19 years of age were included in the review. The defined outcome was completion of the vaccine series within 1 year among those who received the first dose. Results Overall, 6159 abstracts were screened, and 502 full texts were reviewed. Sixty one studies were eligible for this review. All except two were set in high-income countries. Included studies evaluated human papillomavirus vaccine, hepatitis A, hepatitis B, and varicella vaccines. Reported vaccine completion rates, among those who initiated vaccination, ranged from 27 % to over 90 %. Minority racial or ethnic groups and inadequate health insurance coverage were risk factors for low completion, irrespective of initiation rates. Parental healthcare seeking behaviour was positively associated with completion. Vaccine delivery in schools was associated with higher completion than delivery in the community or health facilities. Gender, prior healthcare use and socio-economic status rarely remained significant risks or protective factors in multivariate analysis. Conclusions Almost all studies investigating factors affecting completion have been carried out in developed countries and investigate a limited range of variables. Increased understanding of barriers to completion in adolescents will

  18. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  19. Paediatric urological investigations - dose comparison between urology-related and CT irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Page, Mark; Florescu, Cosmin [Southern Health, Diagnostic Imaging, Melbourne (Australia); Johnstone, Lilian [Monash Children' s Hospital, Department of Paediatrics, Melbourne (Australia); Habteslassie, Daniel [Monash University, Department of Medicine, Melbourne (Australia); Ditchfield, Michael [Southern Health, Diagnostic Imaging, Melbourne (Australia); Monash Children' s Hospital, Diagnostic Imaging, Melbourne (Australia); Monash University, Department of Medicine, Melbourne (Australia)

    2013-07-15

    Urological investigation in children frequently involves high radiation doses; however, the issue of radiation for these investigations receives little attention compared with CT. To compare the radiation dose from paediatric urological investigations with CT, which is commonly regarded as the more major source of radiation exposure. We conducted a retrospective audit in a tertiary paediatric centre of the number and radiation dose of CT scans, micturating cystourethrography exams and urological nuclear medicine scans from 2006 to 2011. This was compared with radiation doses in the literature and an audit of the frequency of these studies in Australia. The tertiary centre audit demonstrated that the ratio of the frequency of urological to CT examinations was 0.8:1 in children younger than 17 years. The ratio of the radiation dose of urological to CT examinations was 0.7:1. The ratio in children younger than 5 years was 1.9:1. In Australia the frequency of urological procedures compared with CT was 0.4:1 in children younger than 17 years and 3.1:1 in those younger than 5 years. The ratio of radiation-related publications was 1:9 favouring CT. The incidence and radiation dose of paediatric urological studies is comparable to those of CT. Nevertheless the radiation dose of urological procedures receives considerably less attention in the literature. (orig.)

  20. Quantitative investigation of physical factors contributing to gold nanoparticle-mediated proton dose enhancement

    International Nuclear Information System (INIS)

    Cho, Jongmin; Manohar, Nivedh; Kerr, Matthew; Cho, Sang Hyun; Gonzalez-Lepera, Carlos; Krishnan, Sunil

    2016-01-01

    Some investigators have shown tumor cell killing enhancement in vitro and tumor regression in mice associated with the loading of gold nanoparticles (GNPs) before proton treatments. Several Monte Carlo (MC) investigations have also demonstrated GNP-mediated proton dose enhancement. However, further studies need to be done to quantify the individual physical factors that contribute to the dose enhancement or cell-kill enhancement (or radiosensitization). Thus, the current study investigated the contributions of particle-induced x-ray emission (PIXE), particle-induced gamma-ray emission (PIGE), Auger and secondary electrons, and activation products towards the total dose enhancement. Specifically, GNP-mediated dose enhancement was measured using strips of radiochromic film that were inserted into vials of cylindrical GNPs, i.e. gold nanorods (GNRs), dispersed in a saline solution (0.3 mg of GNRs/g or 0.03% of GNRs by weight), as well as vials containing water only, before proton irradiation. MC simulations were also performed with the tool for particle simulation code using the film measurement setup. Additionally, a high-purity germanium detector system was used to measure the photon spectrum originating from activation products created from the interaction of protons and spherical GNPs present in a saline solution (20 mg of GNPs/g or 2% of GNPs by weight). The dose enhancement due to PIXE/PIGE recorded on the films in the GNR-loaded saline solution was less than the experimental uncertainty of the film dosimetry (<2%). MC simulations showed highly localized dose enhancement (up to a factor 17) in the immediate vicinity (<100 nm) of GNRs, compared with hypothetical water nanorods (WNRs), mostly due to GNR-originated Auger/secondary electrons; however, the average dose enhancement over the entire GNR-loaded vial was found to be minimal (0.1%). The dose enhancement due to the activation products from GNPs was minimal (<0.1%) as well. In conclusion, under the

  1. Dose-Time Relations for Induction of Lung Cancer in Uranium Miners

    Energy Technology Data Exchange (ETDEWEB)

    Blair, H. A. [University of Rochester School of Medicine and Dentistry, Rochester, NY (United States)

    1969-11-15

    Lack of data on the concentration of radon and daughters in the air inhaled by uranium miners has made it difficult in the past to establish radiation dose and time factors for induction of lung cancer. Recent determinations by others of {sup 210}Pb in the bones of miners who died of cancer provide, however, a new approach. Because {sup 210}Pb, a decay product of radon, accumulates in bone but is also excreted, its concentration, after prolonged exposure, will approach an equilibrium which is a measure of the rate of exposure. It is shown that the {sup 210}Pb. levels in bone at the end of mining are as closely proportional to existing measured and estimated exposure rates to radon as can be expected. It is reasonable, therefore, to use {sup 210}Pb levels in bone as measures of prior exposure rates. When this is done a graph of survival times from beginning of exposures against reciprocal of {sup 210}Pb shows that lung cancer in man exhibits the two types, early and late, previously revealed in bone cancer in dogs and skin cancer in rats. When the dose is high, death follows initiation of cancer in about 7 years. When the dose is low, the usual case, there is an additional latency of 16 years so the time from attainment of initiating dose to death is 23 years. The initiating dose for the high dose type is about 65 pCi {sup 210}Pb per gram years and for the low dose type about 10 pCi per gram years which, in terms of exposure, is about 400 working level months, WLM, as working level, WL, is currently defined. Of the derived parameters the total low dose development time of 23 years is fairly accurate. The high dose development time of 7 years is less certain. The initiating low dose of 10 pCi per gram years is probably moderately accurate, but its counterpart of 400 WLM less certain. The high initiating dose is poorly determined. Twenty three lung cancer cases were involved in this study. Additional cases along with additional environmental and other measurements

  2. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  3. Study on relations between heavy ions single event upset cross sections and γ accumulated doses

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; Wang Yanping; Peng Honglun; Yang Hailiang; Chen Xiaohua; Li Guozheng

    2002-01-01

    Experiments were done under 252 Cf and 60 Co γ source to study the relation between heavy ion Single Event Upset (SEU) cross sections and γ accumulated doses. There was no obvious rule and little influence of γ accumulated doses on SEU cross sections when Static Random Access Memories were in power off mode and static power on mode. In active measuring mode, the SEU cross section increased as the accumulated doses increasing when same data were written in memory cells. If reverse data, such as '55' and 'AA', were written in memory cells during the experiment, the SEU cross sections decreased to the level when memories were not irradiated under 60 Co γ source, even more small. It implied that the influence of γ accumulated doses on SEU cross sections can be set off by this method

  4. Concord Grape Juice Polyphenols and Cardiovascular Risk Factors: Dose-Response Relationships

    Science.gov (United States)

    Blumberg, Jeffrey B.; Vita, Joseph A.; Chen, C. -Y. Oliver

    2015-01-01

    Pure fruit juices provide nutritional value with evidence suggesting some of their benefits on biomarkers of cardiovascular disease risk may be derived from their constituent polyphenols, particularly flavonoids. However, few data from clinical trials are available on the dose-response relationship of fruit juice flavonoids to these outcomes. Utilizing the results of clinical trials testing single doses, we have analyzed data from studies of 100% Concord grape juice by placing its flavonoid content in the context of results from randomized clinical trials of other polyphenol-rich foods and beverages describing the same outcomes but covering a broader range of intake. We selected established biomarkers determined by similar methods for measuring flow-mediated vasodilation (FMD), blood pressure, platelet aggregation, and the resistance of low density lipoprotein cholesterol (LDL) to oxidation. Despite differences among the clinical trials in the treatment, subjects, and duration, correlations were observed between the dose and FMD. Inverse dose-response relationships, albeit with lower correlation coefficients, were also noted for the other outcomes. These results suggest a clear relationship between consumption of even modest serving sizes of Concord grape juice, flavonoid intake, and effects on risk factors for cardiovascular disease. This approach to dose-response relationships may prove useful for testing other individual foods and beverages. PMID:26633488

  5. Evaluation of dose attenuation factor of armored car against radiation accidents

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Fujii, Katsutoshi; Murayama, Takashi

    2002-03-01

    The Tokyo Fire Department developed an armored car against radiation accidents. The car is covered by lead shields for attenuating dose from gamma rays. Dose from neutrons also can be attenuated by pouring water into tanks attached to the surface of the car. However, dose attenuation factors of the radiation shields had been determined by an estimation of single-layer shield, and more precise evaluation of multi-layer shield was required. By request from the Tokyo Fire Department, a precise evaluation of the dose attenuation in multi-layer shield was carried out. The evaluation was made by a Monte Carlo radiation transport simulation code MCNP4B for the shields used in the front, side and back of the car. Three types of the radiation sources ( 252 Cf as a neutron source, 60 Co as a gamma ray source, and radiation source corresponding to the JCO criticality accident) were considered in the calculation. Benchmark experiments using neutron and gamma ray sources were also performed for ensuring the evaluation method. As a result, it was found out that doses of neutron and gamma ray were attenuated to approximately 10% and 25% by the thickest shield, respectively. These values were close to the ones which had already obtained by the estimation of single-layer shield. (author)

  6. Radiation-Induced Rib Fractures After Hypofractionated Stereotactic Body Radiation Therapy: Risk Factors and Dose-Volume Relationship

    Energy Technology Data Exchange (ETDEWEB)

    Asai, Kaori [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Shioyama, Yoshiyuki, E-mail: shioyama@radiol.med.kyushu-u.ac.jp [Department of Heavy Particle Therapy and Radiation Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Nonoshita, Takeshi [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Yoshitake, Tadamasa [Department of Heavy Particle Therapy and Radiation Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Ohnishi, Kayoko [Department of Radiology, National Center for Global Health and Medicine, Tokyo (Japan); Terashima, Kotaro; Matsumoto, Keiji [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Hirata, Hideki [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Honda, Hiroshi [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan)

    2012-11-01

    Purpose: The purpose of this study was to clarify the incidence, the clinical risk factors, and the dose-volume relationship of radiation-induced rib fracture (RIRF) after hypofractionated stereotactic body radiation therapy (SBRT). Methods and Materials: One hundred sixteen patients treated with SBRT for primary or metastatic lung cancer at our institution, with at least 6 months of follow-up and no previous overlapping radiation exposure, were included in this study. To determine the clinical risk factors associated with RIRF, correlations between the incidence of RIRF and the variables, including age, sex, diagnosis, gross tumor volume diameter, rib-tumor distance, and use of steroid administration, were analyzed. Dose-volume histogram analysis was also conducted. Regarding the maximum dose, V10, V20, V30, and V40 of the rib, and the incidences of RIRF were compared between the two groups divided by the cutoff value determined by the receiver operating characteristic curves. Results: One hundred sixteen patients and 374 ribs met the inclusion criteria. Among the 116 patients, 28 patients (46 ribs) experienced RIRF. The estimated incidence of rib fracture was 37.7% at 3 years. Limited distance from the rib to the tumor (<2.0 cm) was the only significant risk factor for RIRF (p = 0.0001). Among the dosimetric parameters used for receiver operating characteristic analysis, the maximum dose showed the highest area under the curve. The 3-year estimated risk of RIRF and the determined cutoff value were 45.8% vs. 1.4% (maximum dose, {>=}42.4 Gy or less), 51.6% vs. 2.0% (V40, {>=}0.29 cm{sup 3} or less), 45.8% vs. 2.2% (V30, {>=}1.35 cm{sup 3} or less), 42.0% vs. 8.5% (V20, {>=}3.62 cm{sup 3} or less), or 25.9% vs. 10.5% (V10, {>=}5.03 cm{sup 3} or less). Conclusions: The incidence of RIRF after hypofractionated SBRT is relatively high. The maximum dose and high-dose volume are strongly correlated with RIRF.

  7. Risk of therapy-related leukaemia and preleukaemia after Hodgkin's disease. Relation to age, cumulative dose of alkylating agents, and time from chemotherapy

    DEFF Research Database (Denmark)

    Pedersen-Bjergaard, J.; Specht, L.; Larsen, S.O.

    1987-01-01

    391 patients treated intensively for Hodgkin's disease were followed for up to 15 years to evaluate the risk of therapy-related acute non-lymphocytic leukaemia (t-ANLL) and preleukaemia. Only two independent factors, patient age and cumulative dose of alkylating agents, were related to the risk...... of t-ANLL. The hazard rate of t-ANLL was roughly proportional to the square of patient age and to the total cumulative dose of alkylating agents. In 320 patients treated with alkylating agents the cumulative risk of t-ANLL increased steadily from 1 year after the start of treatment and reached 13.......0% (SE 3.0) at 10 years after which time there were no further cases. Calculated from cessation of therapy with alkylating agents, however, the cumulative risk curve increased steeply during the first 1-2 years then gradually levelled out and no new cases were observed beyond 7 years. With a 15-year...

  8. Treatment plan modification using voxel-based weighting factors/dose prescription

    International Nuclear Information System (INIS)

    Wu Chuan; Olivera, Gustavo H; Jeraj, Robert; Keller, Harry; Mackie, Thomas R

    2003-01-01

    Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used organ-/ROI-based weighting factors are expanded to a set of voxel-based weighting factors in order to obtain greater flexibility in treatment plan modification. Two different but equivalent modification schemes based on Rustem's quadratic programming algorithms -modification of a weighting matrix and modification of prescribed doses - are presented. Case studies demonstrated the effectiveness of the two methods with regard to their capability to fine-tune treatment plans

  9. Assessment of dose conversion factors in a generic biosphere of a Korea HLW repository

    International Nuclear Information System (INIS)

    Hwang, Y. S.; Park, J. B.; Kang, C. H.

    2002-01-01

    Radioactive species released from a waste repository migrate through engineered and natural barriers and eventually reach the biosphere. Once entered the biosphere, contaminants transport various exposure pathways and finally reach a human. In this study the full RES matrix explaining the key compartments in the biosphere and their interactions is introduced considering the characteristics of the Korean biosphere. Then the three exposure groups are identified based on the compartments of interest. The full exposure pathways and corresponding mathematical expression for mass transfer coefficients and etc are developed and applied to assess the dose conversion factors of nuclides for a specific exposure group. Dose conversion factors assessed in this study will be used for total system performance assessment of a potential Korean HLW repository

  10. Experimental verification of the air kerma to absorbed dose conversion factor Cw,u.

    Science.gov (United States)

    Mijnheer, B J; Wittkämper, F W; Aalbers, A H; van Dijk, E

    1987-01-01

    In a recently published code of practice for the dosimetry of high-energy photon beams, the absorbed dose to water is determined using an ionization chamber having an air kerma calibration factor and applying the air kerma to absorbed dose conversion factor Cw,u. The consistency of these Cw,u values has been determined for four commonly employed types of ionization chambers in photon beams with quality varying between 60Co gamma-rays and 25 MV X-rays. Using a graphite calorimeter, Cw,u has been determined for a graphite-walled ionization chamber (NE 2561) for the same qualities. The values of Cw,u determined with the calorimeter are within the experimental uncertainty equal to Cw,u values determined according to any of the recent dosimetry protocols.

  11. Relative biological effectiveness of 125I seeds for low-dose-rate irradiation of PANC-1

    International Nuclear Information System (INIS)

    Wang Jidong; Wang Junjie; Zhuang Hongqing; Liao Anyan; Zhao Yong

    2008-01-01

    Objective: To investigate the relative biological effectiveness(RBE) of National Model 6711 125 I seeds and the response patterns of PANC-1 exposed to 125 I seeds irradiation. Methods: PANC-1 cells in exponential growth were irradiated at initial dose rate of 2.59 cGy/h in vitro and exposed to 1, 2, 4, 6, 8 and 10 Gy. Meanwhile, the other part of cells were exposed to the same doses by 60 Co at dose rate of 2.21 Gy/min. After irradiation, the cells were stained by trypan blue to measure the cellular mortality rate and to compare the changes along with plating times of 12, 24, 48 and 72 h after 4 Gy. The colonies were counted to obtain the plating efficiencies by colony-forming assay and the cell surviving faction was calculated to plot cell survival curves, and RBE of 125 I seeds relative to 60 Co was determined. Results: The cell death rate for continuous low- dose-rate (LDR) irradiation by 125 I seeds was greater than 60 Co at the same doses above or equal to 4 Gy. After 4 Gy irradiation, the cellular mortality rates were increased with times. The difference was significant between 125 I seeds and 60 Co. The survival fractions of 125 I were lower than those of 60 Co, and the RBE of 125 I relative to 60 Co was determined to be 1.45. Conclusion: The cell-killing effects for continuous low-dose-rate (LDR) irradiation by 125 I seeds are greater than acute high-dose-rate of 60 Co. (authors)

  12. Leadership and Situational Factors Related to AWOL

    Science.gov (United States)

    1971-07-01

    subsequent require- ment placed on military police, legal operations, personnel control facilities, stockades and the correctional training program increase...variables and particularly different aspects of the env,ronmtent. 7 -’:.- -.-’C. . *C? From this overviev , as well as a perusal of an in-depth review ’ of...variahles. The-3nalysis w•’s col•iieted at the University of Wisconsin Computer Center, U!I’,PC 1108 System. Ten factors, dealing with response to AWM

  13. Preliminary Assessment of ICRP Dose Conversion Factor Recommendations for Accident Analysis Applications

    International Nuclear Information System (INIS)

    Vincent, A.M.

    2002-01-01

    Accident analysis for U.S. Department of Energy (DOE) nuclear facilities is an integral part of the overall safety basis developed by the contractor to demonstrate facility operation can be conducted safely. An appropriate documented safety analysis for a facility discusses accident phenomenology, quantifies source terms arising from postulated process upset conditions, and applies a standardized, internationally-recognized database of dose conversion factors (DCFs) to evaluate radiological conditions to offsite receptors

  14. Analysis of the risk factors for exposure of the lung to low irradiation doses

    International Nuclear Information System (INIS)

    Hogeweg, B.

    1986-02-01

    In this report a description is presented of the risk factors for induction of lungtumours. The contribution of natural radioactivity from uranium and thorium to the lungs is mainly caused by inhalation of alpha-emitting radon and thorium daughter products. Apart from exposure by inhalation the lungs are also exposed to external radiation. For internal as well as external exposure a value of 10 -3 lungcancers per Sv lung dose equivalence is found to be acceptable for the riskfactor. (Auth.)

  15. MOTHER – CHILD RELATION AND FACTORS AFFECTING THIS RELATION

    OpenAIRE

    TEZEL ŞAHİN, Fatma

    2014-01-01

    The social institution where a child first meet with his birth and sets his social relations is his family. The communication of parents and other members of family determines the place of child in the family. In the preschool period when the basis of future lives is formed, healthy relations made with child are of great importance. What kind of a person the child starting to perceive himself and his environment in this period will be is determined with the life in this period. Family and rel...

  16. MOTHER – CHILD RELATION AND FACTORS AFFECTING THIS RELATION

    OpenAIRE

    TEZEL ŞAHİN, Fatma

    2015-01-01

    The social institution where a child first meet with his birth and sets his social relations is his family. The communication of parents and other members of family determines the place of child in the family. In the preschool period when the basis of future lives is formed, healthy relations made with child are of great importance. What kind of a person the child starting to perceive himself and his environment in this period will be is determined with the life in this period. Family and rel...

  17. Intraoperative use of low-dose recombinant activated factor VII during thoracic aortic operations.

    Science.gov (United States)

    Andersen, Nicholas D; Bhattacharya, Syamal D; Williams, Judson B; Fosbol, Emil L; Lockhart, Evelyn L; Patel, Mayur B; Gaca, Jeffrey G; Welsby, Ian J; Hughes, G Chad

    2012-06-01

    Numerous studies have supported the effectiveness of recombinant activated factor VII (rFVIIa) for the control of bleeding after cardiac procedures; however safety concerns persist. Here we report the novel use of intraoperative low-dose rFVIIa in thoracic aortic operations, a strategy intended to improve safety by minimizing rFVIIa exposure. Between July 2005 and December 2010, 425 consecutive patients at a single referral center underwent thoracic aortic operations with cardiopulmonary bypass (CPB); 77 of these patients received intraoperative low-dose rFVIIa (≤60 μg/kg) for severe coagulopathy after CPB. Propensity matching produced a cohort of 88 patients (44 received intraoperative low-dose rFVIIa and 44 controls) for comparison. Matched patients receiving intraoperative low-dose rFVIIa got an initial median dose of 32 μg/kg (interquartile range [IQR], 16-43 μg/kg) rFVIIa given 51 minutes (42-67 minutes) after separation from CPB. Patients receiving intraoperative low-dose rFVIIa demonstrated improved postoperative coagulation measurements (partial thromboplastin time 28.6 versus 31.5 seconds; p=0.05; international normalized ratio, 0.8 versus 1.2; pproduct transfusions (2.5 versus 5.0 units; p=0.05) compared with control patients. No patient receiving intraoperative low-dose rFVIIa required postoperative rFVIIa administration or reexploration for bleeding. Rates of stroke, thromboembolism, myocardial infarction, and other adverse events were equivalent between groups. Intraoperative low-dose rFVIIa led to improved postoperative hemostasis with no apparent increase in adverse events. Intraoperative rFVIIa administration in appropriately selected patients may correct coagulopathy early in the course of refractory blood loss and lead to improved safety through the use of smaller rFVIIa doses. Appropriately powered randomized studies are necessary to confirm the safety and efficacy of this approach. Copyright © 2012 The Society of Thoracic Surgeons

  18. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  19. Importance of radiation time and dose factors on outcome for childhood medulloblastoma

    International Nuclear Information System (INIS)

    Back, M.; Barton, M.

    2005-01-01

    The purpose of this study was to investigate the relationship of posterior fossa radiation therapy duration (PFRTD) and relapse-free survival (RFS) following adjuvant craniospinal RT for childhood medulloblastoma. A retrospective audit was performed assessing all children aged 180days) pre-RT chemotherapy were excluded. Data were obtained for potential prognostic factors in domains of patient, tumour and treatment factors. Radiation therapy time factors assessed were PFRTD and time interval from surgery to commencement of RT (SRTD). The end-point assessed was RFS and analysis was performed using Cox regression and Kaplan-Meier survival. One hundred and eighty-nine children were identified from 10 oncology units, with data available from 182 children for analysis. Median follow up was 5.3 years. Seventy-three per cent of children presented with disease confined to the cerebellum; 13% had initial neuraxis disease. Macroscopic resection was described in 54%; 42% received adjuvant chemotherapy. Median RT dose and RT duration to PF was 55 Gy and 45 days, respectively. Seventy-eight relapses occurred with a 10-year actuarial RFS of 58.2% (standard error±4%). On univariate analysis, increasing PF dose (P = 0.002), age >5 years (P 0.006), and more thorough extent of surgical resection (P - 0.043) were associated with improved RFS; PFRTD (P = 0.20) and SRTD (P = 0.51) were not associated with RFS. On multivariate analysis, although both PF dose (P 0.004) and extent of surgery (P = 0.045) remained strongly significant, RT duration was now associated with RFS (P = 0.049). Other factors assessed that did not reach significance were patient age, local tumour extent, presence of internal shunt and use of chemotherapy. The importance of local treatment factors was confirmed in this audit with established prognostic factors such as primary tumour macroscopic resection and adequate PF RT dose being associated with RFS. A treatment time effect is weakly suggested, although less

  20. Prognostic factors of inoperable localized lung cancer treated by high dose radiotherapy

    International Nuclear Information System (INIS)

    Schaake-Koning, C.S.; Schuster-Uitterhoeve, L.; Hart, G.; Gonzalez, D.G.

    1983-01-01

    A retrospective study was made of the results of high dose radiotherapy (greater than or equal to 50 Gy) given to 171 patients with inoperable, intrathoracic non small cell lung cancer from January 1971-April 1973. Local control was dependent on the total tumor dose: after one year local control was 63% for patients treated with >65 Gy, the two year local control was 35%. If treated with 2 , the one year local control was 72%; the two year local control was 44%. Local control was also influenced by the performance status, by the localization of the primary tumor in the left upper lobe and in the periphery of the lung. Local control for tumors in the left upper lobe and in the periphery of the lung was about 70% after one year, and about 40% after two years. The one and two years survival results were correlated with the factors influencing local control. The dose factor, the localization factors and the performance influenced local control independently. Tumors localized in the left upper lobe did metastasize less than tumors in the lower lobe, or in a combination of the two. This was not true for the right upper lobe. No correlation between the TNM system, pathology and the prognosis was found

  1. Task-based measures of image quality and their relation to radiation dose and patient risk

    International Nuclear Information System (INIS)

    Barrett, Harrison H; Kupinski, Matthew A; Myers, Kyle J; Hoeschen, Christoph; Little, Mark P

    2015-01-01

    The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discussed. Then various standard methods for specifying radiation dose are reviewed and related to the mean number of photons in the image and hence to image quality. Current knowledge of the relation between local radiation dose and the risk of various adverse effects is summarized, and some graphical depictions of the tradeoffs between image quality and risk are introduced. Then various dose-reduction strategies are discussed in terms of their effect on task-based measures of image quality. (topical review)

  2. High-dose anti-histamine use and risk factors in children with urticaria.

    Science.gov (United States)

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-12-01

    The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=-0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03-1.15]) and basopenia (OR: 6.77; CI 95%: [2.01-22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. The requirement of high-dose H1-antihistamines was higher with children's increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines.

  3. Radiation dose setting for sterilization of health care items in relation to product microbiological quality

    International Nuclear Information System (INIS)

    Norimah Yusof; Nagi Marsit; Asnah Hassan

    1997-01-01

    Radiation dose of 25 k gray is no longer a generally accepted dose for sterilization. ISO document no. 11137 stated that a manufacturer can decide the dose to sterilize his product depending on the product's microbiological quality (number and type of the contaminants) and the sterility assurance level (SAL) should attain in relation to its usage. Five health care products were selected for the microbiological studies including bio burden counts, identification of most commonly found microorganisms and the radioresistance (D sub 10 value) of the selected isolates. Radiation dose was then determined by two methods, namely Method for Dose Validation of ISO 11137, and calculation based on log survival or population cycle reduction. At a given SAL of 10 sup -6 the radiation sterilization dose obtained by both methods was influenced by microbiological quality of the product. Sterilization dose set by the ISO Method I (Cotton Ball 19.4 kGy, Syringe 20.4 kGy, Suture 15. 0 kGy, Surgical Glove 24.9 kGy and Amnion 17.8 kGy) was higher than the dose calculated according to the log cycle reduction concept in all the products (Cotton Ball 14. 0 kGy, Syringe 15.5 kGy, Suture 11. 6 kGy, Surgical Glove 18. 0 kGy and Amnion 12.6 kGy). The ISO method has limitation on bio products such as amnion and other high valued products which are produced in small number with low bio burden and microorganism spectrum different from those commonly found on medical items

  4. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  5. Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors

    International Nuclear Information System (INIS)

    Tsai, J.-S.; Rivard, Mark J.; Engler, Mark J.; Mignano, John E.; Wazer, David E.; Shucart, William A.

    2003-01-01

    Though the 4 mm Gamma Knife helmet is used routinely, there is disagreement in the Gamma Knife users community on the value of the 4 mm helmet relative output factor. A range of relative output factors is used, and this variation may impair observations of dose response and optimization of prescribed dose. To study this variation, measurements were performed using the following radiation detectors: silicon diode, diamond detector, radiographic film, radiochromic film, and TLD cubes. To facilitate positioning of the silicon diode and diamond detector, a three-dimensional translation micrometer was used to iteratively determine the position of maximum detector response. Positioning of the films and TLDs was accomplished by manufacturing custom holders for each technique. Results from all five measurement techniques indicate that the 4 mm helmet relative output factor is 0.868±0.014. Within the experimental uncertainties, this value is in good agreement with results obtained by other investigators using diverse techniques

  6. Electron dose-rate conversion factors for external exposure of the skin from uniformly deposited activity on the body surface

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1987-01-01

    Dose-rate conversion factors have been calculated for external exposure of the skin from electrons emitted by sources that are deposited uniformly on the body surface. The dose-rate factors are obtained from electron scaled point kernels developed by Berger. The dose-rate factors are calculated at depths of 4, 8, and 40 mg cm-2 below the body surface as recommended by Whitton, and at a depth of 7 mg cm-2 as recommended in ICRP Publication 26 (ICRP77). The dependence of the dose-rate factors at selected depths on the energy of the emitted electrons is displayed. The dose-rate factors for selected radionuclides of potential importance in radiological assessments are tabulated

  7. [Enviromental factors related to depressive disorders].

    Science.gov (United States)

    Hernández-Benítez, Catalina Teresa; García-Rodríguez, Alfonso; Leal-Ugarte, Evelia; Peralta-Leal, Valeria; Durán-González, Jorge

    2014-01-01

    As a result of their high prevalence, mayor depressive disorder single episode (MDDSE); major depressive disorder recurrent episodes (MDDREC); and dysthymia are considered an important public health problem. The objective of this paper was to identify and correlate environmental factors in patients with MDDSE, MDDREC and dysthymia. 121 patients from the Instituto Mexicano del Seguro Social's Subzone General Hospital of San Andres Tuxtla, at Veracruz, were questioned by history with the risk variables. 16 of them were diagnosed with MDDREC, 72 with MDD and 33 with dysthymia; in all of those cases, females prevailed. Depressive disorders were observed more frequently in people over 40 years, married, with medium or low educational level, with dysfunctional family environment, victims of family violence and who were the middle siblings. The main comorbidities that arose were gastrointestinal disorders, obesity and hypertension. 16 of them were diagnosed with MDDREC, 72 with MDD and 33 with dysthymia; in all of those cases, females prevailed. Depressive disorders were observed more frequently in people over 40 years, married, with medium or low educational level, with dysfunctional family environment, victims of family violence and who were the middle siblings. The main comorbidities that arose were gastrointestinal disorders, obesity and hypertension. The main risk factors identified for developing depressive disorders were: being female, over 40 years old and being married. The differences obtained in this study, if it is compared with others, are probably due to sample size, selection criteria and ethnic origin.

  8. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  9. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  10. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.

    1996-09-01

    A preliminary radiological dose assessment of equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials (NORM) in production waste streams. The assessment estimated maximum individual dose equivalents for workers and the general public. Sensitivity analyses of certain input parameters also were conducted. On the basis of this assessment, it is concluded that (1) regulations requiring workers to wear respiratory protection during equipment cleaning operations are likely to result in lower worker doses, (2) underground injection and downhole encapsulation of NORM wastes present a negligible risk to the general public, and (3) potential doses to workers and the general public related to smelting NORM-contaminated equipment can be controlled by limiting the contamination level of the initial feed. It is recommended that (1) NORM wastes be further characterized to improve studies of potential radiological doses; (2) states be encouraged to permit subsurface disposal of NORM more readily, provided further assessments support this study; results; (3) further assessment of landspreading NORM wastes be conducted; and (4) the political, economic, sociological, and nonradiological issues related to smelting NORM-contaminated equipment be studied to fully examine the feasibility of this disposal option

  11. I-131 dose response for incident thyroid cancers in Ukraine related to the Chornobyl accident.

    Science.gov (United States)

    Brenner, Alina V; Tronko, Mykola D; Hatch, Maureen; Bogdanova, Tetyana I; Oliynik, Valery A; Lubin, Jay H; Zablotska, Lydia B; Tereschenko, Valery P; McConnell, Robert J; Zamotaeva, Galina A; O'Kane, Patrick; Bouville, Andre C; Chaykovskaya, Ludmila V; Greenebaum, Ellen; Paster, Ihor P; Shpak, Victor M; Ron, Elaine

    2011-07-01

    Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case-control studies, and studies of prevalent cancers. To address this limitation, we evaluated the dose-response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. The cohort consists of individuals radioactivity measurements taken within 2 months after the accident, environmental transport models, and interview data. Excess radiation risks were estimated using Poisson regression models. Sixty-five incident thyroid cancers were diagnosed during the second through fourth screenings and 73,004 person-years (PY) of observation. The dose-response relationship was consistent with linearity on relative and absolute scales, although the excess relative risk (ERR) model described data better than did the excess absolute risk (EAR) model. The ERR per gray was 1.91 [95% confidence interval (CI), 0.43-6.34], and the EAR per 10⁴ PY/Gy was 2.21 (95% CI, 0.04-5.78). The ERR per gray varied significantly by oblast of residence but not by time since exposure, use of iodine prophylaxis, iodine status, sex, age, or tumor size. I-131-related thyroid cancer risks persisted for two decades after exposure, with no evidence of decrease during the observation period. The radiation risks, although smaller, are compatible with those of retrospective and ecological post-Chornobyl studies.

  12. Relational factors in psychopathological responses to childbirth.

    Science.gov (United States)

    Cigoli, Vittorio; Gilli, Gabriella; Saita, Emanuela

    2006-06-01

    Childbirth can represent for women the time of greatest vulnerability experience, often associated with being out of control, loneliness or sadness. One hundred and sixty women who had 'normal' births were assessed within 48 hours on potential predictive measures and at 3-6 months post-partum for PTSD. Symptoms of depression, anxiety, perceived and desired support by family members, friends, medical personnel were also assessed. t-Test and chi-square were used to analyze, differences between 'risk group' and 'non-risk group'. Few women (1.25%) showed questionnaire responses suggesting clinically significant levels on PTSD; other women (28.75%) reported clinically significant symptoms for at least one subscale. Being at the first delivery experience, together with perceptions of low levels of support from family members and medical personnel, were found to be related to experience of post-traumatic stress symptoms. Anxiety for the child and previous depression are also related to such symptoms. Moreover, anxiety and depression are related to a difficult recognition of the support received, as well as to the desire for more support, in the care of the newborn, from medical professionals.

  13. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C.

    2015-01-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  14. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F. [Universidade Federal do Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Hospital Universitario Maria Aparecida Pedrossian; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C., E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2015-07-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  15. External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting.

    Science.gov (United States)

    Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong

    2013-01-01

    For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.

  16. SU-E-T-517: Investigation of Factors Contributing to Extracranial Radiation Doses From Leksell Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Kon, D [The University of Tokyo Graduate school of Medicine, Tokyo, JP (Japan); Kameda Medical Centre, Chiba, JP (Japan); Nakano, M [The University of Tokyo Graduate school of Medicine, Tokyo, JP (Japan); Nawa, K; Haga, A; Nakagawa, K [University of Tokyo Hospital, Tokyo, JP (Japan)

    2015-06-15

    Purpose The purpose of this study is to investigate dominant factors for doses to extracranial sites in treatment with Leksell Gamma Knife (LGK). Methods Monte Carlo simulation was implemented using EGS5 version 1.4.401. The simulation was divided into two major steps for the purpose of efficiency. As the first step, phase-space files were obtained at a scoring plane located just below patient-side surface of the collimator helmet of LGK. Scored particles were classified into three groups, primary, leakage and scatter, using their history information until their arrival to the scoring plane. Then classification was used at the following second step simulation to investigate which type of particle is dominant in the deposited energy at extra-cranial sites. In the second stage, a cylindrical phantom with a semisphere shaped head was modeled such that the geometrical center of the phantom’s head corresponds to the unit center point (UCP) of LGK. Scoring regions were arranged at 10 cm intervals from the UCP to 70 cm away on the central axis of the phantom. Energy deposition from each type of particles and location of interaction were recorded. Results The dominant factor of deposited energy depended on the collimator size. In the case of smaller collimator size, leakage was dominant. However, contribution of leakage was relatively small in the case of larger collimator size. The contribution of internal scatter varied with the distance from the UCP. In the proximal areas, internal scatter was dominant, whereas in the distal areas, particles interacting with machine components became dominant factor. Conclusion The Result of this study indicates that the dominant factor to dose to an extracranial site can vary with the distance from UCP and with collimator size. This means that the variation of this contribution must be considered for modeling of the extracranial dose especially in the distal area. This work was partly supported by the JSPS Core-to-Core Program (No

  17. Biosphere Dose Conversion Factors for Reasonably Maximally Exposed Individual and Average Member of Critical Group

    International Nuclear Information System (INIS)

    K. Montague

    2000-01-01

    The purpose of this calculation is to develop additional Biosphere Dose Conversion Factors (BDCFs) for a reasonably maximally exposed individual (RMEI) for the periods 10,000 years and 1,000,000 years after the repository closure. In addition, Biosphere Dose Conversion Factors for the average member of a critical group are calculated for those additional radionuclides postulated to reach the environment during the period after 10,000 years and up to 1,000,000 years. After the permanent closure of the repository, the engineered systems within the repository will eventually lose their abilities to contain radionuclide inventory, and the radionuclides will migrate through the geosphere and eventually enter the local water table moving toward inhabited areas. The primary release scenario is a groundwater well used for drinking water supply and irrigation, and this calculation takes these postulated releases and follows them through various pathways until they result in a dose to either a member of critical group or a reasonably maximally exposed individual. The pathways considered in this calculation include inhalation, ingestion, and direct exposure

  18. Application of geometry correction factors for low-level waste package dose measurements. Revision 1

    International Nuclear Information System (INIS)

    Chandler, M.C.; Parish, B.

    1995-01-01

    Plans are to determine the Cs-137 content of low-level waste packages generated in High-Level Waste by measuring the radiation level at a specified distance from the package with a hand-held radiation instrument. The measurement taken at this specified distance, either 3 or 5 feet, is called the far-field measurement. This report documents a method for adjusting the gamma exposure rate (mR/hr) reading used in dose-to-curie determinations when the far-field measurement equals the background reading. This adjustment is necessary to reduce the conservatism resulting from using a minimum detection limit exposure rate for the dose-to-curie determination for the far-field measurement position. To accomplish this adjustment, the near-field (5 cm) measurement is multiplied by a geometry correction factor to obtain an estimate of the far field exposure rate (which is below instrument sensitivity). This estimate of the far field exposure rate is used to estimate the Cs-137 curie content of the package. This report establishes the geometry correction factors for the dose-to-curie determination when the far-field gamma exposure measurement equals the background reading. This report also provides a means of demonstrating compliance to 1S Manual requirements for exposure rate readings at different locations from waste packages while specifying only two measurement positions. This demonstration of compliance is necessary to minimize the number of locations exposure rate measurements that are required, i.e., ALARA

  19. Low Calorie Diet Affects Aging-Related Factors

    Science.gov (United States)

    ... Current Issue Past Issues Research News From NIH Low Calorie Diet Affects Aging-Related Factors Past Issues / ... to learn more about the effects of sustained low-calorie diets in humans on factors affecting aging. ...

  20. Predictor factors in the effectiveness of the therapeutic dose in the Graves diseases

    International Nuclear Information System (INIS)

    Puscar, Ana

    2006-01-01

    The treatment of the Graves diseases includes different options, between which are the antithyroid drugs, 131 I and/or the surgery. Of all of them, the 131 I, it has been increasing the use through the years, going to constitute the treatment of election for many authors, due to the big effectiveness to obtain a rapid healing of this illness. On the other hand, controversies exist about this use, related about the administration doses of 131 I [es

  1. Dose-related estrogen effects on gene expression in fetal mouse prostate mesenchymal cells.

    Directory of Open Access Journals (Sweden)

    Julia A Taylor

    Full Text Available Developmental exposure of mouse fetuses to estrogens results in dose-dependent permanent effects on prostate morphology and function. Fetal prostatic mesenchyme cells express estrogen receptor alpha (ERα and androgen receptors and convert stimuli from circulating estrogens and androgens into paracrine signaling to regulate epithelial cell proliferation and differentiation. To obtain mechanistic insight into the role of different doses of estradiol (E2 in regulating mesenchymal cells, we examined E2-induced transcriptomal changes in primary cultures of fetal mouse prostate mesenchymal cells. Urogenital sinus mesenchyme cells were obtained from male mouse fetuses at gestation day 17 and exposed to 10 pM, 100 pM or 100 nM E2 in the presence of a physiological concentration of dihydrotestosterone (0.69 nM for four days. Gene ontology studies suggested that low doses of E2 (10 pM and 100 pM induce genes involved in morphological tissue development and sterol biosynthesis but suppress genes involved in growth factor signaling. Genes involved in cell adhesion were enriched among both up-regulated and down-regulated genes. Genes showing inverted-U-shape dose responses (enhanced by E2 at 10 pM E2 but suppressed at 100 pM were enriched in the glycolytic pathway. At the highest dose (100 nM, E2 induced genes enriched for cell adhesion, steroid hormone signaling and metabolism, cytokines and their receptors, cell-to-cell communication, Wnt signaling, and TGF- β signaling. These results suggest that prostate mesenchymal cells may regulate epithelial cells through direct cell contacts when estrogen level is low whereas secreted growth factors and cytokines might play significant roles when estrogen level is high.

  2. Dose conversion factors for radiation doses at normal operation discharges. E. Exposure pathways and radioecological data; Dosomraekningsfaktorer foer normaldriftutslaepp. C. Exponeringsvaegar och radioekologiska data

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Sara; Aquilonius, Karin

    2001-10-01

    A study has been performed in order to develop and extend existing models for dose estimations at emissions of radioactive substances from nuclear facilities in Sweden. This report presents a review of all exposure pathways in the project, in order to secure that no important contributions have been omitted. The radioecological data that should be used in calculating conversion factors for air and water emissions are also reviewed. Nuclid-specific conversion factors have been calculated for radiation doses from inhalation and intake for children in different age groups.

  3. Eye lens dosimetry for interventional procedures – Relation between the absorbed dose to the lens and dose at measurement positions

    International Nuclear Information System (INIS)

    Geber, Therese; Gunnarsson, Mikael; Mattsson, Sören

    2011-01-01

    This study investigated the relationship between the absorbed dose to the lens of the eye and the absorbed dose at different measurement positions near the eye of interventional radiologists. It also visualised the dose distribution inside the head, both when protective eyewear were used and without such protection. The best position for an eye lens dosimeter was found to be at the side of the head nearest to the radiation source, close to the eye. Positioning the dosimeter at the eyebrow could lead to an underestimation of the lens dose of as much as 45%. The measured dose distribution showed that the absorbed dose to the eye lenses was high compared to the other parts of the head, which stresses the importance of wearing protective eyewear. However, many models of eyewear were found to be deficient as the radiation could slip through at several places, e.g. at the cheek. The relationship between the absorbed dose to the lens and the kerma-area-product (P KA ) delivered to the patient was also studied.

  4. Comparison of analytic source models for head scatter factor calculation and planar dose calculation for IMRT

    International Nuclear Information System (INIS)

    Yan Guanghua; Liu, Chihray; Lu Bo; Palta, Jatinder R; Li, Jonathan G

    2008-01-01

    The purpose of this study was to choose an appropriate head scatter source model for the fast and accurate independent planar dose calculation for intensity-modulated radiation therapy (IMRT) with MLC. The performance of three different head scatter source models regarding their ability to model head scatter and facilitate planar dose calculation was evaluated. A three-source model, a two-source model and a single-source model were compared in this study. In the planar dose calculation algorithm, in-air fluence distribution was derived from each of the head scatter source models while considering the combination of Jaw and MLC opening. Fluence perturbations due to tongue-and-groove effect, rounded leaf end and leaf transmission were taken into account explicitly. The dose distribution was calculated by convolving the in-air fluence distribution with an experimentally determined pencil-beam kernel. The results were compared with measurements using a diode array and passing rates with 2%/2 mm and 3%/3 mm criteria were reported. It was found that the two-source model achieved the best agreement on head scatter factor calculation. The three-source model and single-source model underestimated head scatter factors for certain symmetric rectangular fields and asymmetric fields, but similar good agreement could be achieved when monitor back scatter effect was incorporated explicitly. All the three source models resulted in comparable average passing rates (>97%) when the 3%/3 mm criterion was selected. The calculation with the single-source model and two-source model was slightly faster than the three-source model due to their simplicity

  5. Comparison of analytic source models for head scatter factor calculation and planar dose calculation for IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Yan Guanghua [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Liu, Chihray; Lu Bo; Palta, Jatinder R; Li, Jonathan G [Department of Radiation Oncology, University of Florida, Gainesville, FL 32610-0385 (United States)

    2008-04-21

    The purpose of this study was to choose an appropriate head scatter source model for the fast and accurate independent planar dose calculation for intensity-modulated radiation therapy (IMRT) with MLC. The performance of three different head scatter source models regarding their ability to model head scatter and facilitate planar dose calculation was evaluated. A three-source model, a two-source model and a single-source model were compared in this study. In the planar dose calculation algorithm, in-air fluence distribution was derived from each of the head scatter source models while considering the combination of Jaw and MLC opening. Fluence perturbations due to tongue-and-groove effect, rounded leaf end and leaf transmission were taken into account explicitly. The dose distribution was calculated by convolving the in-air fluence distribution with an experimentally determined pencil-beam kernel. The results were compared with measurements using a diode array and passing rates with 2%/2 mm and 3%/3 mm criteria were reported. It was found that the two-source model achieved the best agreement on head scatter factor calculation. The three-source model and single-source model underestimated head scatter factors for certain symmetric rectangular fields and asymmetric fields, but similar good agreement could be achieved when monitor back scatter effect was incorporated explicitly. All the three source models resulted in comparable average passing rates (>97%) when the 3%/3 mm criterion was selected. The calculation with the single-source model and two-source model was slightly faster than the three-source model due to their simplicity.

  6. Dose/volume–response relations for rectal morbidity using planned and simulated motion-inclusive dose distributions

    International Nuclear Information System (INIS)

    Thor, Maria; Apte, Aditya; Deasy, Joseph O.; Karlsdóttir, Àsa; Moiseenko, Vitali; Liu, Mitchell; Muren, Ludvig Paul

    2013-01-01

    Background and purpose: Many dose-limiting normal tissues in radiotherapy (RT) display considerable internal motion between fractions over a course of treatment, potentially reducing the appropriateness of using planned dose distributions to predict morbidity. Accounting explicitly for rectal motion could improve the predictive power of modelling rectal morbidity. To test this, we simulated the effect of motion in two cohorts. Materials and methods: The included patients (232 and 159 cases) received RT for prostate cancer to 70 and 74 Gy. Motion-inclusive dose distributions were introduced as simulations of random or systematic motion to the planned dose distributions. Six rectal morbidity endpoints were analysed. A probit model using the QUANTEC recommended parameters was also applied to the cohorts. Results: The differences in associations using the planned over the motion-inclusive dose distributions were modest. Statistically significant associations were obtained with four of the endpoints, mainly at high doses (55–70 Gy), using both the planned and the motion-inclusive dose distributions, primarily when simulating random motion. The strongest associations were observed for GI toxicity and rectal bleeding (Rs = 0.12–0.21; Rs = 0.11–0.20). Applying the probit model, significant associations were found for tenesmus and rectal bleeding (Rs = 0.13, p = 0.02). Conclusion: Equally strong associations with rectal morbidity were observed at high doses (>55 Gy), for the planned and the simulated dose distributions including in particular random rectal motion. Future studies should explore patient-specific descriptions of rectal motion to achieve improved predictive power

  7. Calculation of neutron fluence-to-dose conversion factors for extremities

    International Nuclear Information System (INIS)

    Stewart, R.D.; Harty, R.; McDonald, J.C.; Tanner, J.E.

    1993-04-01

    The Pacific Northwest Laboratory is developing a standard for the performance testing of personnel extremity dosimeters for the US Department of Energy. Part of this effort requires the calculation of neutron fluence-to-dose conversion factors for finger and wrist extremities. This study focuses on conversion factors for two types of extremity models: namely the polymethyl methacrylate (PMMA) phantom (as specified in the draft standard for performance testing of extremity dosimeters) and more realistic extremity models composed of tissue-and-bone. Calculations for each type of model are based on both bare and D 2 O-moderated 252 Cf sources. The results are then tabulated and compared with whole-body conversion factors. More appropriate energy-averaged quality factors for the extremity models have also been computed from the neutron fluence in 50 equally spaced energy bins with energies from 2.53 x 10 -8 to 15 MeV. Tabulated results show that conversion factors for both types of extremity phantom are 15 to 30% lower than the corresponcung whole-body phantom conversion factors for 252 Cf neutron sources. This difference in extremity and whole-body conversion factors is attributable to the proportionally smaller amount of back-scattering that occurs in the extremity phantoms compared with whole-body phantoms

  8. Clinical Factors Associated with Dose of Loop Diuretics After Pediatric Cardiac Surgery: Post Hoc Analysis.

    Science.gov (United States)

    Haiberger, Roberta; Favia, Isabella; Romagnoli, Stefano; Cogo, Paola; Ricci, Zaccaria

    2016-06-01

    A post hoc analysis of a randomized controlled trial comparing the clinical effects of furosemide and ethacrynic acid was conducted. Infants undergoing cardiac surgery with cardiopulmonary bypass were included in order to explore which clinical factors are associated with diuretic dose in infants with congenital heart disease. Overall, 67 patients with median (interquartile range) age of 48 (13-139) days were enrolled. Median diuretic dose was 0.34 (0.25-0.4) mg/kg/h at the end of postoperative day (POD) 0 and it significantly decreased (p = 0.04) over the following PODs; during this period, the ratio between urine output and diuretic dose increased significantly (p = 0.04). Age (r -0.26, p = 0.02), weight (r -0.28, p = 0.01), cross-clamp time (r 0.27, p = 0.03), administration of ethacrynic acid (OR 0.01, p = 0.03), and, at the end of POD0, creatinine levels (r 0.3, p = 0.009), renal near-infrared spectroscopy saturation (-0.44, p = 0.008), whole-blood neutrophil gelatinase-associated lipocalin levels (r 0.30, p = 0.01), pH (r -0.26, p = 0.02), urinary volume (r -0.2755, p = 0.03), and fluid balance (r 0.2577, p = 0.0266) showed a significant association with diuretic dose. At multivariable logistic regression cross-clamp time (OR 1.007, p = 0.04), use of ethacrynic acid (OR 0.2, p = 0.01) and blood pH at the end of POD0 (OR 0.0001, p = 0.03) was independently associated with diuretic dose. Early resistance to loop diuretics continuous infusion is evident in post-cardiac surgery infants: Higher doses are administered to patients with lower urinary output. Independently associated variables with diuretic dose in our population appeared to be cross-clamping time, the administration of ethacrynic acid, and blood pH.

  9. High dose rate brachytherapy for carcinoma of the cervix: risk factors for late rectal complications

    International Nuclear Information System (INIS)

    Uno, Takashi; Itami, Jun; Aruga, Moriyo; Kotaka, Kikuo; Fujimoto, Hajime; Minoura, Shigeki

    1996-01-01

    Purpose/Objective: To determine the incidence of late rectal complications in patients treated with high dose rate brachytherapy for FIGO stage IIB, IIIB carcinoma of the uterine cervix, and to evaluate the treatment factors associated with an increased probability of treatment complications. Materials and Methods: Records of 100 patients with FIGO IIB or IIIB cervical carcinoma treated with definitive irradiation using high dose rate intracavitary brachytherapy (HDR-ICR) between 1977 and 1994 were retrospectively reviewed. For each HDR-ICR session, 6 Gy isodose volume was reconstructed three dimensionally and the following three parameters were determined to represent this isodose volume, length (L); maximum longitudinal distance of 6 Gy isodose area in an oblique frontal plane containing the intrauterine applicator, width (W); maximum width of 6 Gy isodose area in the same plane, height (H); maximum dimension of 6 Gy isodose area perpendicular to the intrauterine applicator determined in the oblique sagittal plane. Point P/Q (2 cm ventral/dorsal from the proximal retention point of the intrauterine source) and point R/S (2 cm ventral/dorsal from the midpoint of the ovoid sources) were also defined retrospectively and HDR-ICR dose at these points were calculated. Statistical analyses were performed to determine the treatment factors predictive of late rectal complications. Results: The 5-year cumulative cause-specific disease-free survival rate was 50% for all, 74% for Stage IIB, and 38% for Stage IIIB, with a significant difference between two FIGO Stages (p=0.0004). Of patients treated for both stages, 30% and 36% had experienced moderate to severe (Grade 2-4) complications at 3 and 5 years, respectively. Average H value (p=0.013) and cumulative point S dose by HDR-ICR (p=0.020) were significantly correlated with the incidence of late rectal complications (Student's t-test), whereas these factors did not significantly affect the probability of pelvic control. No

  10. Dose and dose rate extrapolation factors for malignant and non-malignant health endpoints after exposure to gamma and neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Van; Little, Mark P. [National Cancer Institute, Radiation Epidemiology Branch, Rockville, MD (United States)

    2017-11-15

    Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and

  11. Energy-dependency correction factors for the digital dosimeters using in NMD environment dose assessment

    International Nuclear Information System (INIS)

    Lai, Y.C.; Huang, Y. F.; Chen, Y.W.

    2008-01-01

    Full text: Short-term environment dose-rate assessments using real-time digital dosimeters within a Nuclear Medicine Department (NMD) are gaining more world-wide uses recently. In the past, conventional ion chamber-type survey-meters are used dominantly in environmental dose rates evaluation. Although it has suffered less gamma energy-dependency, but it is less sensitive in comparison with other digital dosimeters and more bulky in design that can hardly make it into a pocket size application. With modern electronic advancement and its shrinking in physical size, real-time personal dosimeter nowadays has gaining more popular to use a miniature G-M counter or a solid-state diode sensor, or even a NaI(Tl) scintillation device for ambient radiation monitoring. Radiation sensor operated in pulse-mode can never been used in doses or dose rates determination since each digital pulse has carried no energy information of the impinging gamma ray being interactive with, especially in the G-M counter or the diode sensor case. The raw count rates measured from a pulse-mode device are heavily dependent on the packaging of the sensor to make it less energy-sensitive. The doses or dose rates are then calculated by using a built-in conversion factor, based on a Cs-137 beam source calibration data conducted by various manufacturing vendors, to convert its raw counts into a so-called dose or dose-rate unit. In this study, we have focused our interests in the low energy response of the digital dosimeters from several brands currently for our in-house uses. Mainly, Tc-99m and I-131 in point sources and water phantoms detection configurations have been deployed to simulate our NMD outpatients for environment radiation monitoring purpose. The energy-dependent correction factors of the digital dosimeters will be evaluated by using calibrated Tc-99m or I-131 standard sources directly that has much lower gamma energy than the Cs-137 beam source of 661 keV. In the near future, we would

  12. Dose factors to calculate the radiation exposure due to radioactive waste air from nuclear facilities

    International Nuclear Information System (INIS)

    Brenk, H.D.; Vogt, K.J.

    1977-01-01

    An evaluation of the environmental impact of nuclear plants according to paragraph 45 of the Radiation Protection Directive of the Federal Republic of Germany requires the calculation of dose conversion factors indicating the correlation between the contaminated medium and individual radiation exposure. The present study is to be conceived as a contribution to discussion on this subject. For the determination of radiation exposure caused by the waste air of nuclear plants, models are being specified for computing the dose conversion factors for the external exposure pathways of β-submersion, γ-submersion and γ-radiation from contaminated ground as well as the internal exposure pathways of inhalation and ingestion, which further elaborate and improve the models previously applied, especially as far as the ingestion pathway is concerned, which distinguishes between 6 major food categories. The computer models are applied to those radionuclides which are significan for nuclear emitters, in particular nuclear light-water power stations. The results obtained for the individual exposure pathways and affected organs are specified in the form of tables. For this purpose, calculations were first of all carried out for the so-called 'reference man'. The results can be transferred to population groups with different consumption habits (e.g. vegetarians) by the application of correction factors. The models are capable of being extended with a view to covering other age groups. (orig.) [de

  13. Patient absorbed radiation doses estimation related to irradiation anatomy; Estimativa de dose absorvida pelo paciente relacionada a anatomia irradiada

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes, E-mail: prof.flavio@gmail.com, E-mail: amanda-a-soares@hotmail.com, E-mail: gabriellygkahl@gmail.com [Instituto Federal de Eduacao, Ciencia e Tecnologia de Santa Catarina (IFSC), Florianopolis, SC (Brazil)

    2014-07-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector.

  14. Report of the Nuclear Energy Agency expert group on gut transfer factors: implications for dose per unit intake

    International Nuclear Information System (INIS)

    1988-01-01

    This note describes the gut transfer factors recommended by an Expert Group of the Nuclear Energy Agency for intakes of certain important elements in food and drinking water. The evidence behind the recommendations is discussed and their implications for dose per unit intake is investigated. It is found that in many cases the dose per unit intake calculated using the gut uptake factor recommended by the Expert Group is similar to that calculated using the recommendations of ICRP Publication 30. However, in some cases there are substantial increases in dose per unit intake. The largest increases are by a factor of fifty for intakes of certain thorium isotopes by infants. (author)

  15. Scattering factor evaluation for internal dose assessment due to 60Co

    International Nuclear Information System (INIS)

    Gautam, Y.P.; Kumar, A.; Sharma, S.; Sharma, A.K.; Dube, B.; Hegde, A.G.

    2008-01-01

    Guidelines for the assessment of internal doses from monitoring suggest default measurement of uncertainties (i.e. lognormal scattering factor, SF) to be used for different types of monitoring data. In this paper, SF values have been evaluated for internal contamination due to 60 Co in two cases using whole body counting data. SF values of 1.04 and 1.03 were obtained for case I and II respectively while SF value of 1.03 was obtained using bioassay data for case I. SF evaluated is in good agreement with the default values given by IDEAS guidelines. (author)

  16. Transfer factors for assessing the dose from radionuclides in agricultural products

    International Nuclear Information System (INIS)

    Ng, Y.C.; Colsher, C.S.; Thompson, S.E.

    1979-01-01

    Transfer factors to predict the environmental transport of radionuclides through terrestrial foodchains to man were derived from the literature for radionuclides associated with the nuclear fuel cycle. We present updated transfer coefficients to predict the concentration of a radionuclide in cow's milk and other animal products and concentration factors (CF) to predict the concentration in a food or feed crop from that in soil. Where possible we note the variation of the transfer factor with physical and chemical form of the radionuclide and environmental factors, and characterize the distribution and uncertainty in the estimate. The updated transfer factors are compared with those listed in regulatory guides. The new estimates lead to recommended changes (both increases and decreases) in the listed transfer coefficients for milk and meat and to the suggested practice of adopting multiple soil-to-plant CF's that vary with the type of crop and soil in the place of a single generic CF to predict the concentration of a radionuclide in a crop from that in soil. The updated transfer factors will be useful to assess the dose from radionuclides released from nuclear facilities and evaluating compliance with regulations governing the release of radionuclides

  17. Factors related to innovative output in the Dutch agrifood industry

    NARCIS (Netherlands)

    Batterink, M.H.; Wubben, E.F.M.; Omta, S.W.F.

    2006-01-01

    The present study assessed the factors related to innovative output in the Dutch agrifood industry, a scale-intensive, supplierdominated industry. We concentrated on explanatory variables related to cooperation, information sources, innovation objectives, obstacles to innovation, and innovation

  18. A feasibility assessment of calculation procedure with case study and the modification of dose conversion factor in STARDOSE

    International Nuclear Information System (INIS)

    Ko, H. S.; Jang, M.; Kim, S. H.; Kang, C. S.

    2003-01-01

    STARDOSE computer code is the designed code for which is calculated the dose of control room and off-site dose on design basis accident of nuclear power plant. Input files of STARDOSE are libfile1.txt which has decay constant and dose conversion factor, and input.dat which structurally expresses the real plant model by editor. It is given much advanced result with using newer dose conversion factor in libfile1.txt. In this study, therefore, case study is performed that is made input.dat file for LOCA and libfile1.txt which is included newer dose conversion factor and core inventory on APR-1400 and UCN 5 and 6. The result of case study is compared and analyzed

  19. Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil

    CERN Document Server

    Clouvas, A; Antonopoulos-Domis, M; Silva, J

    2000-01-01

    The dose rate conversion factors D/sub CF/ (absorbed dose rate in air per unit activity per unit of soil mass, nGy h/sup -1/ per Bq kg/sup -1/) are calculated 1 m above ground for photon emitters of natural radionuclides uniformly distributed in the soil. Three Monte Carlo codes are used: 1) The MCNP code of Los Alamos; 2) The GEANT code of CERN; and 3) a Monte Carlo code developed in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki. The accuracy of the Monte Carlo results is tested by the comparison of the unscattered flux obtained by the three Monte Carlo codes with an independent straightforward calculation. All codes and particularly the MCNP calculate accurately the absorbed dose rate in air due to the unscattered radiation. For the total radiation (unscattered plus scattered) the D/sub CF/ values calculated from the three codes are in very good agreement between them. The comparison between these results and the results deduced previously by other authors indicates a good ag...

  20. Relative dose efficiencies of antiscatter grids and air gaps in pediatric radiography

    International Nuclear Information System (INIS)

    McDaniel, D.L.; Cohen, G.; Wagner, L.K.; Robinson, L.H.

    1984-01-01

    The relative dose efficiencies (RDE) of various antiscatter grids and air gaps were determined for conditions simulating those found in pediatric radiography, using phantoms representing a newborn child, a 5-yr-old and a 10-yr-old child. Our data indicate than an air gap is best for the newborn, due to the low levels of scatter. The 8:1 fiber grid or 15.2-cm air gap without a grid can improve dose efficiency (DE) for the 5-yr-old child by 20%--25% relative to the 3.3-cm air gap and no-grid technique, while for the 10-yr-old child, DE can be improved by 40% with an 8:1 fiber grid

  1. Study of dose and relative risk of occupationally exposed individuals in interventional procedures

    International Nuclear Information System (INIS)

    Silveira Filho, Jose A.M.; Reis, Charlene O.; Taniguti, Lana T.; Pacifico, Leonardo C.; SaintYves, Thalis L.A.; Mecca, Fernando A.

    2012-01-01

    This paper estimates the occupational effective dose and the relative risk of leukemia and cancers of the digestive tract mortality through dose study of the most radiosensitive anatomical regions (lens, thyroid, chest and gonads) of the professionals involved in interventional gonad procedures. It was considered a cumulative exposure time of 10,000 hours, which is the occupational exposure time of an IOE in throughout his professional life. It was also considered that they always use Personal Protective Equipment (PPE). Mathematical models derived from epidemiological data contained in the BEIR V and in the IAEA’s TECDOC 870 are used to estimate the relative risk. The results show a significant increase in mortality risk for these types of cancer for individuals occupationally exposed to three different distances from the x-ray beam, and reinforces that radiation protection measures are essential. (author)

  2. Dose conformity of gamma knife radiosurgery and risk factors for complications

    International Nuclear Information System (INIS)

    Nakamura, Jean L.; Verhey, Lynn J.; Smith, Vernon; Petti, Paula L.; Lamborn, Kathleen R.; Larson, David A.; Wara, William M.; McDermott, Michael W.; Sneed, Penny K.

    2001-01-01

    Purpose: To quantitatively evaluate dose conformity achieved using Gamma Knife radiosurgery, compare results with those reported in the literature, and evaluate risk factors for complications. Methods and Materials: All lesions treated at our institution with Gamma Knife radiosurgery from May 1993 (when volume criteria were routinely recorded) through December 1998 were reviewed. Lesions were excluded from analysis for reasons listed below. Conformity index (the ratio of prescription volume to target volume) was calculated for all evaluable lesions and for lesions comparable to those reported in the literature on conformity of linac radiosurgery. Univariate Cox regression models were used to test for associations between treatment parameters and toxicity. Results: Of 1612 targets treated in 874 patients, 274 were excluded, most commonly for unavailability of individual prescription volume data because two or more lesions were included within the same dose matrix (176 lesions), intentional partial coverage for staged treatment of large arteriovenous malformations (AVMs) (33 lesions), and missing target volume data (26 lesions). The median conformity indices were 1.67 for all 1338 evaluable lesions and 1.40-1.43 for lesions comparable to two linac radiosurgery series that reported conformity indices of 1.8 and 2.7, respectively. Among all 651 patients evaluable for complications, there were one Grade 5, eight Grade 4, and 27 Grade 3 complications. Increased risk of toxicity was associated with larger target volume, maximum lesion diameter, prescription volume, or volume of nontarget tissue within the prescription volume. Conclusions: Gamma Knife radiosurgery achieves much more conformal dose distributions than those reported for conventional linac radiosurgery and somewhat more conformal dose distributions than sophisticated linac radiosurgery techniques. Larger target, nontarget, or prescription volumes are associated with increased risk of toxicity

  3. HIGH-DOSE CHEMOTHERAPY WITH STEM-CELL REINFUSION AND GROWTH-FACTOR SUPPORT FOR SOLID TUMORS

    NARCIS (Netherlands)

    DEVRIES, EGE; DEGRAAF, H; VANDERGRAAF, WTA; MULDER, NH; Boonstra, A.

    1995-01-01

    With the help of stem cell reinfusion and hematopoietic growth factors, it is possible to get up to a ten-fold dose increase for certain chemotherapeutic drugs, A number of reasons may have made high-dose chemotherapy less dangerous and the fore more acceptable in a more upfront treatment setting,

  4. Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams.

    Science.gov (United States)

    Seuntjens, J P; Ross, C K; Shortt, K R; Rogers, D W

    2000-12-01

    Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorbed dose to water standards. In these protocols use is made of the absorbed-dose beam quality conversion factor, kQ which scales an absorbed-dose calibration factor at the reference quality 60Co to a quality Q, and which is calculated based on state-of-the-art ion chamber theory and data. In this paper we present the measurement and analysis of beam quality conversion factors kQ for cylindrical chambers in high-energy photon beams. At least three chambers of six different types were calibrated against the Canadian primary standard for absorbed dose based on a sealed water calorimeter at 60Co [TPR10(20)=0.572, %dd(10)x=58.4], 10 MV [TPR10(20)=0.682, %dd(10)x=69.6), 20 MV (TPR10(20)=0.758, %dd(10)x= 80.5] and 30 MV [TPR10(20) = 0.794, %dd(10)x= 88.4]. The uncertainty on the calorimetric determination of kQ for a single chamber is typically 0.36% and the overall 1sigma uncertainty on a set of chambers of the same type is typically 0.45%. The maximum deviation between a measured kQ and the TG-51 protocol value is 0.8%. The overall rms deviation between measurement and the TG-51 values, based on 20 chambers at the three energies, is 0.41%. When the effect of a 1 mm PMMA waterproofing sleeve is taken into account in the calculations, the maximum deviation is 1.1% and the overall rms deviation between measurement and calculation 0.48%. When the beam is specified using TPR10(20), and measurements are compared with kQ values calculated using the version of TG-21 with corrected formalism and data, differences are up to 1.6% when no sleeve corrections are taken into account. For the NE2571 and the NE2611A chamber types, for which the most literature data are

  5. The Thoron Issue: Monitoring Activities, Measuring Techniques and Dose Conversion Factors (invited paper)

    International Nuclear Information System (INIS)

    Nuccetelli, C.; Bochicchio, F.

    1998-01-01

    The health risk due to the presence of thoron indoors is usually neglected because of its generally low concentration in indoor environments, which is essentially caused by its short half-life. However, in certain not uncommon situations, such as when thorium-rich building materials are used, thoron ( 220 Rn) may represent a significant source of radioactive exposure. In recent years, renewed interest has led to more intensive monitoring of thoron gas and its decay products. A tentatively comprehensive summary of these measurement results and a review of the most innovative measurement techniques for 220 Rn are here presented. Finally, dose-exposure conversion factors currently used for thoron decay products are analysed, highlighting the poorer basis of such factors, when compared to those for radon. (author)

  6. Coverage, efficacy or dosing interval: which factor predominantly influences the impact of routine childhood vaccination for the prevention of varicella? A model-based study for Italy

    Directory of Open Access Journals (Sweden)

    Katsiaryna Holl

    2016-10-01

    Full Text Available Abstract Background Varicella is a highly infectious disease with a significant public health and economic burden, which can be prevented with childhood routine varicella vaccination. Vaccination strategies differ by country. Some factors are known to play an important role (number of doses, coverage, dosing interval, efficacy and catch-up programmes, however, their relative impact on the reduction of varicella in the population remains unclear. This paper aims to help policy makers prioritise the critical factors to achieve the most successful vaccination programme with the available budget. Methods Scenarios assessed the impact of different vaccination strategies on reduction of varicella disease in the population. A dynamic transmission model was used and adapted to fit Italian demographics and population mixing patterns. Inputs included coverage, number of doses, dosing intervals, first-dose efficacy and availability of catch-up programmes, based on strategies currently used or likely to be used in different countries. The time horizon was 30 years. Results Both one- and two-dose routine varicella vaccination strategies prevented a comparable number of varicella cases with complications, but two-doses provided broader protection due to prevention of a higher number of milder varicella cases. A catch-up programme in susceptible adolescents aged 10–14 years old reduced varicella cases by 27–43 % in older children, which are often more severe than in younger children. Coverage, for all strategies, sustained at high levels achieved the largest reduction in varicella. In general, a 20 % increase in coverage resulted in a further 27–31 % reduction in varicella cases. When high coverage is reached, the impact of dosing interval and first-dose vaccine efficacy had a relatively lower impact on disease prevention in the population. Compared to the long (11 years dosing interval, the short (5 months and medium (5 years interval schedules

  7. The expression and evolution of virulence in multiple infections: the role of specificity, relative virulence and relative dose.

    Science.gov (United States)

    Ben-Ami, Frida; Routtu, Jarkko

    2013-05-03

    Multiple infections of the same host by different strains of the same microparasite species are believed to play a crucial role during the evolution of parasite virulence. We investigated the role of specificity, relative virulence and relative dose in determining the competitive outcome of multiple infections in the Daphnia magna-Pasteuria ramosa host-parasite system. We found that infections by P. ramosa clones (single genotype) were less virulent and produced more spores than infections by P. ramosa isolates (possibly containing multiple genotypes). We also found that two similarly virulent isolates of P. ramosa differed considerably in their within-host competitiveness and their effects on host offspring production when faced with coinfecting P. ramosa isolates and clones. Although the relative virulence of a P. ramosa isolate/clone appears to be a good indicator of its competitiveness during multiple infections, the relative dose may alter the competitive outcome. Moreover, spore counts on day 20 post-infection indicate that the competitive outcome is largely decided early in the parasite's growth phase, possibly mediated by direct interference or apparent competition. Our results emphasize the importance of epidemiology as well as of various parasite traits in determining the outcome of within-host competition. Incorporating realistic epidemiological and ecological conditions when testing theoretical models of multiple infections, as well as using a wider range of host and parasite genotypes, will enable us to better understand the course of virulence evolution.

  8. Time and dose-related changes in the thickness of pig skin after irradiation with single doses of [sup 90]Sr/[sup 90]Y [beta]-rays

    Energy Technology Data Exchange (ETDEWEB)

    Rezvani, M.; Hamlet, R.; Hopewell, J.W.; Sieber, V.K. (Churchill Hospital, Oxford (United Kingdom))

    1994-04-01

    Time-related changes in pig skin thickness have been evaluated using a non-invasive ultrasound technique after exposure to a range of single doses of [sup 90]Sr/[sup 90]Yr [beta]-rays. The reduction in relative skin thickness developed in two distinct phases: the first was between 12 and 20 weeks postirradiation. No further changes were then seen until 52 weeks postirradiation when a second phase of skin thinning was observed. This was complete after 76 weeks and no further changes in relative skin thickness were seen in the maximum follow up period of 129 weeks. The timings of these phases of damage were independent of the radiation dose, however, the severity of both phases of radiation-induced skin thinning were dose related. (Author).

  9. Time and dose-related changes in the thickness of pig skin after irradiation with single doses of 90Sr/90Y β-rays

    International Nuclear Information System (INIS)

    Rezvani, M.; Hamlet, R.; Hopewell, J.W.; Sieber, V.K.

    1994-01-01

    Time-related changes in pig skin thickness have been evaluated using a non-invasive ultrasound technique after exposure to a range of single doses of 90 Sr/ 90 Yr β-rays. The reduction in relative skin thickness developed in two distinct phases: the first was between 12 and 20 weeks postirradiation. No further changes were then seen until 52 weeks postirradiation when a second phase of skin thinning was observed. This was complete after 76 weeks and no further changes in relative skin thickness were seen in the maximum follow up period of 129 weeks. The timings of these phases of damage were independent of the radiation dose, however, the severity of both phases of radiation-induced skin thinning were dose related. (Author)

  10. Correction factors in the EPR dose reconstruction for residents of the Middle and Lower Techa riverside.

    Science.gov (United States)

    Romanyukha, A A; Seltzer, S M; Desrosiers, M; Ignatiev, E A; Ivanov, D V; Bayankin, S; Degteva, M O; Eichmiller, F C; Wieser, A; Jacob, P

    2001-11-01

    During 1949-1956, the first Soviet nuclear weapons plant, Mayak, released about 7.6 x 10(7) m(-3) of liquid radioactive waste with a total activity of 10(17) Bq into the Techa River (Southern Urals, Russia). 90Sr contributed 11.6% to the total waste radioactivity. As a result of these radioactive discharges, about 28,000 local residents were exposed to ionizing radiation, and some of them received relatively high doses. Internal exposure of the population residing at the Middle and Lower Techa riverside was mostly from 90Sr deposited in bone and tooth tissues. In order to reconstruct radiation doses to this population group, a study of 35 teeth extracted from local residents was carried out using electron paramagnetic resonance measurements. A total of 73 samples from these 35 teeth (tooth enamel, 33; crown dentin, 20; and root dentin, 20) were prepared and measured with electron paramagnetic resonance. The study revealed high doses (up to 15 Gy) absorbed in tooth enamel of the individuals born during 1945-1949, which was attributed to very high local 90Sr concentration in tooth enamel of this particular age group in the population. The analysis presented here takes into account (a) the time courses both of the release/intake of 90Sr and of the tooth formation, and (b) expected variations in measured absorbed doses due to differing geometric sizes of tooth structures. This methodology enables a more consistent picture to be developed of the 90Sr intake by the Middle and Lower Techa riverside population, based on electron paramagnetic resonance tooth dosimetry.

  11. PROGNOSTIC FACTORS FOR PRIMARY CENTRAL NERVOUS SYSTEM LYMPHOMAS TREATED WITH HIGH-DOSE METHOTREXATE-BASED CHEMO-RADIOTHERAPY

    Science.gov (United States)

    Nagane, Motoo; Lee, Jeunghun; Shishido-Hara, Yukiko; Suzuki, Kaori; Shimizu, Saki; Umino, Michiru; Kobayashi, Keiichi; Shiokawa, Yoshiaki

    2014-01-01

    BACKGROUND: Chemotherapy with high-dose methotrexate (HD-MTX) followed by whole brain radiotherapy (WBRT) is a conventional approach to treat primary central nervous system lymphomas (PCNSL), but some tumors relapse early leading to unfavorable outcome. Several biomarkers have been identified as prognostic factors in PCNSL, however, the correlation of both clinical factors including those related to MTX metabolism and B-cell differentiation and oncogenic biomarkers with response to and outcome by therapy is yet unclear. METHODS: We investigated 32 immunocompetent patients (19 males, 13 females) with PCNSL (all diffuse large B-cell type) treated with HD-MTX based therapy with or without WBRT since 2000 in our institution. Paraffin-embedded formalin-fixed tumor tissue sections were stained immunohistochemically with antibodies against following factors: B-cell differentiation markers (CD10, Bcl-6, Mum-1, CD138); MTX metabolism-related (MRP family, LRP, DHFR); cell cycle-related (p27KIP1, MIB-1); drug resistance-related (MGMT, MLH1, MSH2, MSH6, PMS2); and oncogenes (Myc, Bcl-2). Correlation between positivity of these factors and clinical outcomes were evaluated using logrank test and cox regression analysis. RESULTS: Among these factors, complete response to HD-MTX was significantly associated with longer progression-free survival (PFS)(P = 0.0012), while Bcl-6 expression as well as histological subtype (non-germinal center B-cell, non-GCB) was closely correlated with shorter PFS. Age (>60) (P = 0.006) and MSH2 expression (P = 0.017) were found to be better predictor for overall survival (OS), but in multivariate analysis, they were no longer significant. Other factors involved in MTX metabolism, DNA repair enzymes, and oncogenes did not affect outcome. CONCLUSIONS: Non-GCB subtype and Bcl-6 expression may be associated with worse outcome in patients with PCNSL treated with HD-MTX, while MTX-metabolism related factors did not influence prognosis. Further

  12. Revised age-dependent doses to members of the public from intake of radionuclides using the new tissue weighting factors

    International Nuclear Information System (INIS)

    Jain, S.C.; Gupta, M.M.; Nagaratnam, A.; Reddy, A.R.; Mehta, S.C.

    1992-01-01

    ICRP 56 gave age-dependent dose coefficients to members of the public from intake of most radiologically significant radionuclides that might be released to the environment due to various human activities. It has computed effective dose equivalent (now called effective dose) from these dose coefficients utilising the tissue weighting factors as given by ICRP 26. The recent ICRP 1990 recommendations have revised the tissue weighting factors based on new information on risk estimates of fatal cancer and hereditary disorders. This change in the tissue weighting factors will subsequently affect the computation of effective dose due to intake of various radio-nuclides considered by ICRP 56. The revised effective doses for ingested as well as inhaled radionuclides have been worked out and compared from corresponding earlier values. No change was found in the case of tritiated water, organically bound tritium and 14 C. For the majority of the radionuclides, the revised effective dose was within ± 20% of the earlier values. Larger variations in effective dose were noted for radionuclides which deposit preferentially in one or two organs. (author)

  13. Multi-walled carbon nanotubes: A cytotoxicity study in relation to functionalization, dose and dispersion.

    Science.gov (United States)

    Zhou, Lulu; Forman, Henry Jay; Ge, Yi; Lunec, Joseph

    2017-08-01

    Chemical functionalization broadens carbon nanotube (CNT) applications, conferring new functions, but at the same time potentially altering toxicity. Although considerable experimental data related to CNT toxicity, at the molecular and cellular levels, have been reported, there is very limited information available for the corresponding mechanism involved (e.g. cell apoptosis and genotoxicity). The threshold dose for safe medical application in relation to both pristine and functionalized carbon nanotubes remains ambiguous. In this study, we evaluated the in vitro cytotoxicity of pristine and functionalized (OH, COOH) multi-walled carbon nanotubes (MWCNTs) for cell viability, oxidant detection, apoptosis and DNA mutations, to determine the non-toxic dose and influence of functional group in a human lung-cancer cell line exposed to 1-1000μg/ml MWCNTs for 24, 48 and 72h. The findings suggest that pristine MWCNTs induced more cell death than functionalized MWCNTs while functionalized MWCNTs are more genotoxic compared to their pristine form. The level of both dose and dispersion in the matrix used should be taken into consideration before applying further clinical applications of MWCNTs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Low-Dose, Ionizing Radiation and Age-Related Changes in Skeletal Microarchitecture

    Directory of Open Access Journals (Sweden)

    Joshua S. Alwood

    2012-01-01

    Full Text Available Osteoporosis can profoundly affect the aged as a consequence of progressive bone loss; high-dose ionizing radiation can cause similar changes, although less is known about lower doses (≤100 cGy. We hypothesized that exposure to relatively low doses of gamma radiation accelerates structural changes characteristic of skeletal aging. Mice (C57BL/6J-10 wk old, male were irradiated (total body; 0-sham, 1, 10 or 100 cGy 137Cs and tissues harvested on the day of irradiation, 1 or 4 months later. Microcomputed tomography was used to quantify microarchitecture of high turnover, cancellous bone. Irradiation at 100 cGy caused transient microarchitectural changes over one month that were only evident at longer times in controls (4 months. Ex vivo bone cell differentiation from the marrow was unaffected by gamma radiation. In conclusion, acute ionizing gamma irradiation at 100 cGy (but not at 1 cGy or 10 cGy exacerbated microarchitectural changes normally found during progressive, postpubertal aging prior to the onset of age-related osteoporosis.

  15. Low-dose radiation therapy for choroidal neovascularization in age-related macular degeneration

    International Nuclear Information System (INIS)

    Matsuhashi, Hideaki; Takahashi, Daisuke; Mariya, Yasushi; Tarusawa, Nobuko; Yoshimoto, Hiroshi; Matsuyama, Shuichi; Noda, Yasuko.

    1996-01-01

    The efficacy of low-dose radiation was evaluated in the treatment of eyes with subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. Ten eyes of ten patients received a total dose of 14 Gy of 10 MV X-rays in seven fractions and the mean follow-up time was 12 months (range 9-18 months). Thirteen control eyes of thirteen patients were followed for an average of 18 months (range 12-24 months). Visual acuity was improved in 2 eyes (20%), unchanged in 3 eyes (30%), and deteriorated in 5 eyes (50%) of treated patients, and it was improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients at their last follow-up examinations. Funduscopic and angiographic findings were improved in 3 eyes (30%), unchanged in 2 eyes (20%), and deteriorated in 5 eyes (50%) of treated patients, and they were improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients. These results suggested that low-dose radiation is beneficial for the management of subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. (author)

  16. Low-dose radiation therapy for choroidal neovascularization in age-related macular degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Hideaki; Takahashi, Daisuke; Mariya, Yasushi; Tarusawa, Nobuko; Yoshimoto, Hiroshi; Matsuyama, Shuichi [Hirosaki Univ., Aomori (Japan). School of Medicine; Noda, Yasuko

    1996-10-01

    The efficacy of low-dose radiation was evaluated in the treatment of eyes with subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. Ten eyes of ten patients received a total dose of 14 Gy of 10 MV X-rays in seven fractions and the mean follow-up time was 12 months (range 9-18 months). Thirteen control eyes of thirteen patients were followed for an average of 18 months (range 12-24 months). Visual acuity was improved in 2 eyes (20%), unchanged in 3 eyes (30%), and deteriorated in 5 eyes (50%) of treated patients, and it was improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients at their last follow-up examinations. Funduscopic and angiographic findings were improved in 3 eyes (30%), unchanged in 2 eyes (20%), and deteriorated in 5 eyes (50%) of treated patients, and they were improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients. These results suggested that low-dose radiation is beneficial for the management of subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. (author)

  17. Ozone dosing alters the biological potential and therapeutic outcomes of plasma rich in growth factors.

    Science.gov (United States)

    Anitua, E; Zalduendo, M M; Troya, M; Orive, G

    2015-04-01

    Until now, ozone has been used in a rather empirical way. This in-vitro study investigates, for the first time, whether different ozone treatments of plasma rich in growth factors (PRGF) alter the biological properties and outcomes of this autologous platelet-rich plasma. Human plasma rich in growth factors was treated with ozone using one of the following protocols: a continuous-flow method; or a syringe method in which constant volumes of ozone and PRGF were mixed. In both cases, ozone was added before, during and after the addition of calcium chloride. Three ozone concentrations, of the therapeutic range 20, 40 and 80 μg/mL, were tested. Fibrin clot properties, growth factor content and the proliferative effect on primary osteoblasts and gingival fibroblasts were evaluated. Ozone treatment of PRGF using the continuous flow protocol impaired formation of the fibrin scaffold, drastically reduced the levels of growth factors and significantly decreased the proliferative potential of PRGF on primary osteoblasts and gingival fibroblasts. In contrast, treatment of PRGF with ozone using the syringe method, before, during and after the coagulation process, did not alter the biological outcomes of the autologous therapy. These findings suggest that ozone dose and the way that ozone combines with PRGF may alter the biological potential and therapeutic outcomes of PRGF. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Status of Los Alamos efforts related to Hiroshima and Nagasaki dose estimates

    International Nuclear Information System (INIS)

    Whalen, P.P.

    1981-09-01

    The Los Alamos efforts related to resolution of the Hiroshima, Nagasaki doses are described as follows: (1) Using recently located replicas of the Hiroshima bomb, measurements will be made which will define the upper limit of the Hiroshima yield. (2) Two-dimensional calculations of the neutron and gamma-ray outputs of the Hiroshima and Nagasaki weapons are in progress. Neutron and gamma-ray leakage spectra measurements will be made. Similar measurements on the Mark 9 weapon and on the Ichiban assembly are proposed. These measurements will provide a check for present day cross sections and calculations. (3) Calculations of several air transport experiments are in progress. A comparison of calculated results with experimental results is given. (4) The neutron and gamma-ray output spectra of several devices tested in the atmosphere at the Nevada Test Site are being calculated. The results of these calculations will allow models of the debris cloud contribution to the total dose to be tested

  19. Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E

    2003-07-01

    In reviewing tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdose hits in exposed micromasses for a given radiation quality. DNA damage increases with the number of microdose hits. They also can induce adaptive protection, mainly against endogenous DNA damage. This protection involves cellular defenses, DNA repair and damage removal. With increasing numbers of low linear energy transfer (LET) microdose hits in exposed micromasses, adaptive protection first tends to outweigh damage and then (above 200 mGy) fails and largely disappears. These experimental data predict that cancer risk coefficients derived by epidemiology at high-dose irradiation decline at low doses and dose rates when adaptive protection outdoes DNA damage. The dose-risk function should include both linear and non-linear terms at low doses. (author)

  20. Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach

    International Nuclear Information System (INIS)

    Feinendegen, L.E.

    2003-01-01

    In reviewing tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdose hits in exposed micromasses for a given radiation quality. DNA damage increases with the number of microdose hits. They also can induce adaptive protection, mainly against endogenous DNA damage. This protection involves cellular defenses, DNA repair and damage removal. With increasing numbers of low linear energy transfer (LET) microdose hits in exposed micromasses, adaptive protection first tends to outweigh damage and then (above 200 mGy) fails and largely disappears. These experimental data predict that cancer risk coefficients derived by epidemiology at high-dose irradiation decline at low doses and dose rates when adaptive protection outdoes DNA damage. The dose-risk function should include both linear and non-linear terms at low doses. (author)

  1. Effect of physiological factors on dose due to organically bound tritium

    International Nuclear Information System (INIS)

    Trivedi, A.

    1998-01-01

    The International Commission on Radiological Protection (ICRP) recommends the understanding of the effect of age, anatomical and physiological data on the doses in order to prescribe dose coefficient for radionuclides. The published data on OBT dose fraction after acute or chronic intakes of HTO are evaluated to examine the variation of OBT dose with the age and physiology of occupational workers. (author)

  2. Uncertainty of relative sensitivity factors in glow discharge mass spectrometry

    Science.gov (United States)

    Meija, Juris; Methven, Brad; Sturgeon, Ralph E.

    2017-10-01

    The concept of the relative sensitivity factors required for the correction of the measured ion beam ratios in pin-cell glow discharge mass spectrometry is examined in detail. We propose a data-driven model for predicting the relative response factors, which relies on a non-linear least squares adjustment and analyte/matrix interchangeability phenomena. The model provides a self-consistent set of response factors for any analyte/matrix combination of any element that appears as either an analyte or matrix in at least one known response factor.

  3. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Kimberly Fernandes

    Full Text Available To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity.Interventional time-series analysis.Ontario, Canada, from 2003 to 2014.Ontario Drug Benefit (ODB beneficiaries aged 15 to 64 years from 2003 to 2014.Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010 and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011.Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions.Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03 which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43. Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7% over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68 or enactment of the NSAA (p-value = .59.Although the Canadian clinical practice guidelines for use of opioids in chronic non

  4. Latitude and ultraviolet radiation dose in the birthplace in relation to menarcheal age in a large cohort of French women.

    Science.gov (United States)

    Dossus, Laure; Kvaskoff, Marina; Bijon, Anne; Engel, Pierre; Verdebout, Jean; Fervers, Béatrice; Boutron-Ruault, Marie-Christine; Clavel-Chapelon, Françoise; Mesrine, Sylvie

    2013-04-01

    Age at menarche is an important determinant of hormonal-related neoplasia and other chronic diseases. Spatial and temporal variations in age at menarche have been observed in industrialised countries and several environmental factors were reported to have an influence. We examined geographical variations in self-reported age at menarche and explored the effects of both latitude and ultraviolet radiation (UVR) dose on the onset of menarche in 88,278 women from the French E3N cohort (aged 40-65 years at inclusion). The mean age at menarche was 12.8 years. After adjustment for potential confounders (birth cohort, prematurity, birth weight and length, father's income index, body silhouette in childhood, food deprivation during World War II, population of birthplace, number of siblings, breastfeeding exposure and indoor exposure to passive smoking during childhood), latitude and UVR dose (annual or spring/summer) in county of birth were significantly associated with age at menarche (P(trend) < 0.0001). Women born at lower latitudes or in regions with higher annual or spring/summer UVR dose had a 3- to 4-month earlier menarche than women born at higher latitudes or in regions with lower UVR. On a continuous scale, a 1° increment in latitude resulted in a 0.04-year older age at menarche [95% confidence interval (CI): 0.03, 0.05], whereas a 1-kJ/m(2) increment in annual UVR dose resulted in a 0.42-year younger age at menarche (95% CI: -0.55, -0.29). These data further suggest that light exposure in childhood may influence sexual maturation in women.

  5. ACCEPTABILITY EVALUATION FOR USING ICRP TISSUE WEIGHTING FACTORS TO CALCULATE EFFECTIVE DOSE VALUE FOR SEPARATE GENDER-AGE GROUPS OF RUSSIAN FEDERATION

    Directory of Open Access Journals (Sweden)

    L. V. Repin

    2013-01-01

    Full Text Available An article describes radiation risk factors for several gender-age population groups according to Russian statistical and medical-demographic data, evaluates the lethality rate for separate nosologic forms of malignant neoplasms based on Russian cancer registries according to the method of the International Agency for Cancer Research. Relative damage factors are calculated for the gender-age groups under consideration. The tissue weighting factors recommended by ICRP to calculate effective doses are compared with relative damage factors calculated by ICRP for the nominal population and with similar factors calculated in this work for separate population cohorts in theRussian Federation. The significance of differences and the feasibility of using tissue weighting factors adapted for the Russian population in assessing population risks in cohorts of different gender-age compositions have been assessed.

  6. EPR spectrum deconvolution and dose assessment of fossil tooth enamel using maximum likelihood common factor analysis

    International Nuclear Information System (INIS)

    Vanhaelewyn, G.; Callens, F.; Gruen, R.

    2000-01-01

    In order to determine the components which give rise to the EPR spectrum around g = 2 we have applied Maximum Likelihood Common Factor Analysis (MLCFA) on the EPR spectra of enamel sample 1126 which has previously been analysed by continuous wave and pulsed EPR as well as EPR microscopy. MLCFA yielded agreeing results on three sets of X-band spectra and the following components were identified: an orthorhombic component attributed to CO - 2 , an axial component CO 3- 3 , as well as four isotropic components, three of which could be attributed to SO - 2 , a tumbling CO - 2 and a central line of a dimethyl radical. The X-band results were confirmed by analysis of Q-band spectra where three additional isotropic lines were found, however, these three components could not be attributed to known radicals. The orthorhombic component was used to establish dose response curves for the assessment of the past radiation dose, D E . The results appear to be more reliable than those based on conventional peak-to-peak EPR intensity measurements or simple Gaussian deconvolution methods

  7. Derivation of ingestion dose conversion factors for the U-238 decay series

    International Nuclear Information System (INIS)

    Jenkins, P.H.; Nicoll, R.M.; Doty, R.L.

    1978-01-01

    Dose conversion factors (DCF's) for the U-238 decay series were derived for use in the assessment of potential doses to man, through several ingestion pathways, by radionuclide deposition from radioactive airborne effluents. The methodology used, although similar to that outlined in the U.S. Nuclear Regulatory Commission's Regulatory Guide 1.109, is complicated by consideration of the ingrowth of decay products. Eight ingestion pathways were considered: (1) fresh vegetables, (2) stored vegetables, (3) milk from cows that eat pasture grass, (4) milk from cows that eat stored feed, (5) goat milk - pasture grass, (6) goat milk - stored feed, (7) beef - pasture grass, and (8) beef - stored feed. Radionuclide deposition was assumed to occur for the entire operational lifetime of the facility. Because the expected operational lifetime may vary from facility to facility, DCF's were calculated for six lifetimes: 10, 15, 20, 25, 30, and 35 years. DCF's were calculated for each of 13 'parent' nuclides in the decay series, with each DCF considering the ingrowth of all subsequent nuclides in the series. The methodology used to derive the DCF's is detailed, and DCF's normalized to a deposition rate of the parent nuclide of 1 μCi m -2 s -1 are reported. (author)

  8. Factoring vs linear modeling in rate estimation: a simulation study of relative accuracy.

    Science.gov (United States)

    Maldonado, G; Greenland, S

    1998-07-01

    A common strategy for modeling dose-response in epidemiology is to transform ordered exposures and covariates into sets of dichotomous indicator variables (that is, to factor the variables). Factoring tends to increase estimation variance, but it also tends to decrease bias and thus may increase or decrease total accuracy. We conducted a simulation study to examine the impact of factoring on the accuracy of rate estimation. Factored and unfactored Poisson regression models were fit to follow-up study datasets that were randomly generated from 37,500 population model forms that ranged from subadditive to supramultiplicative. In the situations we examined, factoring sometimes substantially improved accuracy relative to fitting the corresponding unfactored model, sometimes substantially decreased accuracy, and sometimes made little difference. The difference in accuracy between factored and unfactored models depended in a complicated fashion on the difference between the true and fitted model forms, the strength of exposure and covariate effects in the population, and the study size. It may be difficult in practice to predict when factoring is increasing or decreasing accuracy. We recommend, therefore, that the strategy of factoring variables be supplemented with other strategies for modeling dose-response.

  9. Acute pancreatitis related to therapeutic dosing with colchicine: a case report

    Directory of Open Access Journals (Sweden)

    Ting Joseph

    2007-08-01

    Full Text Available Abstract Background Colchicine is used in the treatment and prophylaxis of gout. It possesses a narrow therapeutic window, frequently resulting in dose-limiting gastrointestinal side-effects such as diarrhoea and emesis. As colchicine is a cellular anti-mitotic agent, the most serious effects include myelosuppression, myoneuropathy and multiple organ failure. This occurs with intentional overdose or with therapeutic dosing in patients with reduced clearance of colchicine due to pre-existing renal or hepatic impairment. Acute pancreatitis has rarely been reported, and only in association with severe colchicine overdose accompanied by multi-organ failure. Case presentation We report a case of acute pancreatitis without other organ toxicity related to recent commencement of colchicine for acute gout, occurring in an elderly male with pre-existing renal impairment. Conclusion 1 Colchicine should be used with care in elderly patients or patients with impaired renal function. 2 Aside from myelosuppression, myoneuropathy and multiple organ failure, colchicine may now be associated with acute pancreatitis even with therapeutic dosing; this has not previously being reported.

  10. A preliminary examination of audience-related communications issues for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, C.W.

    1991-04-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project will estimate radiation doses people may have received from exposure to radioactive materials released during past operations at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. The HEDR Project was initiated in response to public concerns about possible health impacts from past releases of radioactive materials from Hanford. The TSP recognized early in the project that special mechanisms would be required to effectively communicate to the many different concerned audiences. Accordingly, the TSP directed PNL to examine methods for communicating causes and effects of uncertainties in the dose estimates. After considering the directive and discussing it with the Communications Subcommittee of the TSP, PNL undertook a broad investigation of communications methods to consider for inclusion in the TSP's current communications program. As part of this investigation, a literature review was conducted regarding risk communications. A key finding was that, in order to successfully communicate risk-related information, a thorough understanding of the knowledge level, concerns and information needs of the intended recipients (i.e., the audience) is necessary. Hence, a preliminary audience analysis was conducted as part of the present research. This report summarizes the results of this analysis. 1 ref., 9 tabs.

  11. Biosphere analysis - a complementary assessment of dose conversion factors for the Olkiluoto site

    International Nuclear Information System (INIS)

    Kylloenen, J.; Keto, V.

    2010-04-01

    The Olkiluoto site is currently the primary candidate for the final disposal site for spent nuclear fuel from the Olkiluoto and Loviisa NPPs. Safety analysis calculations must be performed to verify the compliance with the long-term safety requirements. The behaviour and distribution of radionuclides in the biosphere is of high importance in these calculations. The aim of this study was to perform a complementary assessment of dose conversion factors for the Olkiluoto site. Posiva has performed extensive analysis on the different ecosystems. In this work the biosphere analysis model of Fortum Nuclear Services (FNS) is used to give an independent estimate of biosphere dose conversion factors for the Olkiluoto site. The following nuclides are analysed: Cl-36, Ni-59, Se-79, Mo-93, Nb-94, Sn-126, I-129 and Cs-135. The FNS model is an equilibrium compartment model in which a steady annual release of 1 Bq of each radionuclide is distributed in different scenarios. The scenarios are the well scenario, which models a small agricultural ecosystem, the lake scenario which models a larger ecosystem with both agriculture and lake use, and sea and transition scenario, which models the behaviour of the radionuclides in marine environments. The scenarios are described and the transfer equations written for the lake scenario. The parameter values are taken from the FNS biosphere database, which has been used in the Finnish L/ILW waste repository safety analyses since mid 1990's. The results of the FNS analysis are compared to those presented in Posiva working report 2000-20 (POSIVA-WR-00-20). The results are of the same order of magnitude for all nuclides except I-129. Since the Posiva and FNS models were independently constructed, the results can be considered as convincing, and the compliance of the results give confidence to the modelling results. (orig.)

  12. Comparison of effective doses using tissue-weighting factors in the 1977, 1990, and 2007 recommendations of the ICRP

    International Nuclear Information System (INIS)

    Matsunaga, Yuta; Kawaguchi, Ai; Suzuki, Shoichi

    2013-01-01

    The International Commission on Radiological Protection (ICRP) has established recommended tissue-weighting factors. Although there have been international reports on effective doses using the factors listed in the 1977, 1990, and 2007 recommendations of the ICRP, there have been no papers in Japan. The aim of this study was to evaluate effective doses using the tissue-weighting factors listed in each recommendation of the ICRP under 2011 exposure conditions in Japan. We used a human body phantom to estimate patient exposure doses during chest, abdomen, lumbar spine (anteroposterior and lateral), and head radiographs. With thermoluminescence dosimeters placed at various positions on and in the phantom, radiation doses were determined. There was little change in the effective doses to the chest and head from each recommendation. However, the effective doses recommended in 1977 were 0.2 mSv to the abdomen, 0.1 mSv to the lumbar spine anteroposteriorally, and 0.1 mSv to the lumbar spine laterally; these values are lower than those recommended in 1990 and 2007, which were 0.5 mSv to the abdomen, 0.4 mSv to the lumbar spine anteroposteriorally, and 0.6 mSv to the lumbar spine laterally. We could evaluate the effective doses using each recommendation and 2011 exposure conditions in Japan. (author)

  13. Determination of attenuation factors for mortar of barite in terms of environmental dose equivalent and effective dose

    International Nuclear Information System (INIS)

    Almeida Junior, Airton T.; Campos, L.L.R.; Araujo, F.G.S.; Santos, M.A.P.; Nogueira, M.S.

    2014-01-01

    This work addresses the characterization of barite mortars used as Xray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H⁎(10). The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic Xray equipment - radiation conditions for use in the determination of characteristics. In this study values was determined experimentally for the attenuation of the Cream barite (density 2.99g/cm 3 , collected in the state of Sao Paulo), Purple barite (density 2.95g/cm 3 , collected in the state of Bahia) and White barite (density 3.10g/cm 3 , collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. In the experimental procedure, these proof bodies were irradiated with a Pantak, model HF320 industrial X-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barite studied concerning the capacity to attenuate X-ray radiation for X-ray beams ranging from 60 to 150 kV indicated

  14. Evaluation of some predisposing factors to malaria related anaemia ...

    African Journals Online (AJOL)

    Evaluation of some predisposing factors to malaria related anaemia among children in Benin City, Nigeria. ... Tropical Journal of Health Sciences ... It was carried out at the University of Benin Teaching Hospital, Benin City between June and ...

  15. Sport psychological skill levels and related psychosocial factors that ...

    African Journals Online (AJOL)

    Sport psychological skill levels and related psychosocial factors that distinguish ... players' perceived ability to be psychologically well prepared for competitions. ... reference to practical implications for future sport psychological skills training

  16. Lack of Radiation Dose or Quality Dependence of Epithelial-to-Mesenchymal Transition (EMT) Mediated by Transforming Growth Factor β

    International Nuclear Information System (INIS)

    Andarawewa, Kumari L.; Costes, Sylvain V.; Fernandez-Garcia, Ignacio; Chou, William S.; Ravani, Shraddha A.; Park, Howard; Barcellos-Hoff, Mary Helen

    2011-01-01

    Purpose: Epithelial-to-mesenchymal transition (EMT) is a phenotype that alters cell morphology, disrupts morphogenesis, and increases motility. Our prior studies have shown that the progeny of human mammary epithelial cells (HMECs) irradiated with 2 Gy undergoes transforming growth factor β (TGF-β)-mediated EMT. In this study we determined whether radiation dose or quality affected TGF-β-mediated EMT. Methods and Materials: HMECs were cultured on tissue culture plastic or in Matrigel (BD Biosciences, San Jose, CA) and exposed to low or high linear energy transfer (LET) and TGF-β (400 pg/mL). Image analysis was used to measure membrane-associated E-cadherin, a marker of functional epithelia, or fibronectin, a product of mesenchymal cells, as a function of radiation dose and quality. Results: E-cadherin was reduced in TGF-β-treated cells irradiated with low-LET radiation doses between 0.03 and 2 Gy compared with untreated, unirradiated cells or TGF-β treatment alone. The radiation quality dependence of TGF-β-mediated EMT was determined by use of 1 GeV/amu (gigaelectron volt / atomic mass unit) 56 Fe ion particles at the National Aeronautics and Space Administration's Space Radiation Laboratory. On the basis of the relative biological effectiveness of 2 for 56 Fe ion particles' clonogenic survival, TGF-β-treated HMECs were irradiated with equitoxic 1-Gy 56 Fe ion or 2-Gy 137 Cs radiation in monolayer. Furthermore, TGF-β-treated HMECs irradiated with either high- or low-LET radiation exhibited similar loss of E-cadherin and gain of fibronectin and resulted in similar large, poorly organized colonies when embedded in Matrigel. Moreover, the progeny of HMECs exposed to different fluences of 56 Fe ion underwent TGF-β-mediated EMT even when only one-third of the cells were directly traversed by the particle. Conclusions: Thus TGF-β-mediated EMT, like other non-targeted radiation effects, is neither radiation dose nor quality dependent at the doses examined.

  17. Elderly Taiwanese's Intrinsic Risk Factors for Fall-related Injuries

    OpenAIRE

    In-Fun Li; Yvonne Hsiung; Hui-Fen Hsing; Mei-Yu Lee; Te-Hsin Chang; Ming-Yuan Huang

    2016-01-01

    Background: As a vital issue in geriatric research, risk factors for falls were concluded to be multifactorial, and prevention has been mostly aimed at decreasing situational and environmental risks that cause and aggravate fall-related injuries, particularly within the institutions. While knowledge is limited about older patients' intrinsic determinants, the purpose of this study was to explore elderly Taiwanese's intrinsic risk factors associated with severe fall-related injuries. Method...

  18. SU-F-T-686: Considerations About Dose Protraction Factor in TCP Calculations for Prostate VMAT Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Clemente, F; Perez-Vara, C; Clavo, M [Herranz Hospital Central de la Defensa “Gomez Ulla”, Madrid (Spain)

    2016-06-15

    Purpose: Dose protraction factor should be considered in order to model the TCP calculations. Nevertheless, this study describes a brief discussion showing that the lack of its inclusion should not invalidate these calculations for prostate VMAT treatments. Methods: Dose protraction factor (G) modifies the quadratic term of the linear-quadratic expression in order to take into account the sublethal damage repair of protracting the dose delivery. If the delivery takes a short time (instantaneous), G = 1. For any other dose delivery pattern, G < 1. The Lea-Catcheside dose protraction factor for external beam radiotherapy contains terms depending of on the tissue specific repair parameter (λ) and the irradiation time (T). Expanding the exponential term using a Taylor’s series and neglecting terms of order (λT){sup 3}, the approximation leads to G = 1. The described situation occurs for 3DCRT techniques, where treatment times are about few minutes. For IMRT techniques, fraction times are prolonged compared to 3DCRT times. Wang et al. (2003) and Fowler et al. (2004) investigated the protraction effect with respect to IMRT treatments, reporting clinically significant loss in biological effect associated with IMRT delivery times. Results: Treatment times are noticeably reduced for prostate treatments using VMAT techniques. These times are comparable to 3DCRT times, leading to consider the previous approximation. Conclusion: Dose protraction factor can be approximated by G = 1 in TCP calculations for prostate treatments using VMAT techniques.

  19. Effective dose per unit kerma-area product conversion factors in adults undergoing modified barium swallow studies

    International Nuclear Information System (INIS)

    Shaw Bonilha, Heather; Wilmskoetter, Janina; Tipnis, Sameer V.; Martin-Harris, Bonnie; Huda, Walter

    2017-01-01

    This study presents an investigation of adult effective dose (E) per unit Kerma-Area Product (KAP) in Modified Barium Swallow Study (MBSS) examinations. PC program for X-ray Monte Carlo (version 2.0.1) was used to calculate patient organ doses during MBSS examinations, which used combined to generate effective dose. Normalized patient doses were obtained by dividing the effective dose (mSv) by the incident KAP (Gy.cm 2 ). Five standard projections were studied and the importance of X-ray beam size and in patient size (body mass index) were investigated. Lateral projections had an average E/ KAP conversion factor of 0.19 ± 0.04 mSv/Gy.cm 2 . The average E/KAP was highest for upper gastrointestinal (GI) anterior- posterior projections (0.27 ± 0.04 mSv/Gy.cm 2 ) and lowest for upper GI posterior-anterior projections (0.09 ± 0.03 mSv/ Gy.cm 2 ). E/KAP always increased with increasing filtration and/or X-ray tube voltage. Reducing the X-ray beam cross-sectional area increased the E/KAP conversion factors. Small patients have the E/KAP conversion factors that are twice those of a standard adult. Conversion factors for effective dose of adult patients undergoing MBSS examinations must account for X-ray beam projection, beam quality (kV and filtration), image size and patient size. (authors)

  20. Age-related changes in factor VII proteolysis in vivo.

    Science.gov (United States)

    Ofosu, F A; Craven, S; Dewar, L; Anvari, N; Andrew, M; Blajchman, M A

    1996-08-01

    Previous studies have reported that pre-operative plasmas of patients over the age of 40 years who developed post-operative deep vein thrombosis (DVT) had approximately twice the amount of proteolysed factor VII found in plasmas of patients in whom prophylaxis with heparin or low M(r) heparin was successful. These and other studies also reported higher concentrations of thrombin-antithrombin III in pre- and post-operative plasmas of patients who developed post-operative thrombosis than in plasmas of patients in whom prophylaxis was successful. Whether the extent of factor VII proteolysis seen in the patients who developed post-operative DVT is related to the severity of their disease or age is not known. This report investigated age-related changes in the concentrations of total factor VII protein, factor VII zymogen, factor VIIa, tissue factor pathway inhibitor, thrombin-antithrombin III, and prothrombin fragment 1 + 2 in normal plasmas and the relationships between these parameters. With the exception of thrombin-antithrombin III, statistically significant increases in the concentrations of these parameters with age were found. Additionally, the differences between the concentrations of total factor VII protein and factor VII zymogen, an index factor VII proteolysis in vivo, were statistically significant only for individuals over age 40. Using linear regression analysis, a significant correlation was found to exist between the concentrations of plasma factor VIIa and prothrombin fragment 1 + 2. Since factor VIIa-tissue factor probably initiates coagulation in vivo, we hypothesize that the elevated plasma factor VIIa (reflecting a less tightly regulated tissue factor activity and therefore increased thrombin production in vivo) accounts for the high risk for post-operative thrombosis seen in individuals over the age of 40.

  1. Protection by GDNF and other trophic factors against the dopamine-depleting effects of neurotoxic doses of methamphetamine.

    Science.gov (United States)

    Cass, Wayne A; Peters, Laura E; Harned, Michael E; Seroogy, Kim B

    2006-08-01

    Repeated methamphetamine (METH) administration to animals can result in long-lasting decreases in striatal dopamine (DA) content. It has previously been shown that glial cell line-derived neurotrophic factor (GDNF) can reduce the DA-depleting effects of neurotoxic doses of METH. However, there are several other trophic factors that are protective against dopaminergic toxins. Thus, the present experiments further investigated the protective effect of GDNF as well as the protective effects of several other trophic factors. Male Fischer-344 rats were given an intracerebral injection of trophic factor (2-10 microg) 1 day before METH (5 mg/kg, s.c., 4 injections at 2-h intervals). Seven days later DA levels in the striatum were measured using high-performance liquid chromatography (HPLC). Initial experiments indicated that only intrastriatal GDNF, and not intranigral GDNF, was protective. Thereafter, all other trophic factors were administered into the striatum. Members of the GDNF family (GDNF, neurturin, and artemin) all provided significant protection against the DA-depleting effects of METH, with GDNF providing the greatest protection. Brain-derived neurotrophic factor, neurotrophin-3, acidic fibroblast growth factor, basic fibroblast growth factor, ciliary neurotrophic factor, transforming growth factor-alpha (TGF-alpha), heregulin beta1 (HRG-beta1), and amphiregulin (AR) provided no significant protection at the doses examined. These results suggest that the GDNF family of trophic factors can provide significant protection against the DA-depleting effects of neurotoxic doses of METH.

  2. Influence of photon beam energy on the dose enhancement factor caused by gold and silver nanoparticles: An experimental approach

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, Eder José, E-mail: ederguidelli@pg.ffclrp.usp.br; Baffa, Oswaldo [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Av. Bandeirantes, 3900, 14040-901 Ribeirão Preto, SP (Brazil)

    2014-03-15

    Purpose: Noble metal nanoparticles have found several medical applications in the areas of radiation detection; x-ray contrast agents and cancer radiation therapy. Based on computational methods, many papers have reported the nanoparticle effect on the dose deposition in the surrounding medium. Here the authors report experimental results on how silver and gold nanoparticles affect the dose deposition in alanine dosimeters containing several concentrations of silver and gold nanoparticles, for five different beam energies, using electron spin resonance spectroscopy (ESR). Methods: The authors produced alanine dosimeters containing several mass percentage of silver and gold nanoparticles. Nanoparticle sizes were measured by dynamic light scattering and by transmission electron microscopy. The authors determined the dose enhancement factor (DEF) theoretically, using a widely accepted method, and experimentally, using ESR spectroscopy. Results: The DEF is governed by nanoparticle concentration, size, and position in the alanine matrix. Samples containing gold nanoparticles afford a DEF higher than 1.0, because gold nanoparticle size is homogeneous for all gold concentrations utilized. For samples containing silver particles, the silver mass percentage governs the nanoparticles size, which, in turns, modifies nanoparticle position in the alanine dosimeters. In this sense, DEF decreases for dosimeters containing large and segregated particles. The influence of nanoparticle size-position is more noticeable for dosimeters irradiated with higher beam energies, and dosimeters containing large and segregated particles become less sensitive than pure alanine (DEF < 1). Conclusions: ESR dosimetry gives the DEF in a medium containing metal nanoparticles, although particle concentration, size, and position are closely related in the system. Because this is also the case as in many real systems of materials containing inorganic nanoparticles, ESR is a valuable tool for

  3. Influence of photon beam energy on the dose enhancement factor caused by gold and silver nanoparticles: An experimental approach

    International Nuclear Information System (INIS)

    Guidelli, Eder José; Baffa, Oswaldo

    2014-01-01

    Purpose: Noble metal nanoparticles have found several medical applications in the areas of radiation detection; x-ray contrast agents and cancer radiation therapy. Based on computational methods, many papers have reported the nanoparticle effect on the dose deposition in the surrounding medium. Here the authors report experimental results on how silver and gold nanoparticles affect the dose deposition in alanine dosimeters containing several concentrations of silver and gold nanoparticles, for five different beam energies, using electron spin resonance spectroscopy (ESR). Methods: The authors produced alanine dosimeters containing several mass percentage of silver and gold nanoparticles. Nanoparticle sizes were measured by dynamic light scattering and by transmission electron microscopy. The authors determined the dose enhancement factor (DEF) theoretically, using a widely accepted method, and experimentally, using ESR spectroscopy. Results: The DEF is governed by nanoparticle concentration, size, and position in the alanine matrix. Samples containing gold nanoparticles afford a DEF higher than 1.0, because gold nanoparticle size is homogeneous for all gold concentrations utilized. For samples containing silver particles, the silver mass percentage governs the nanoparticles size, which, in turns, modifies nanoparticle position in the alanine dosimeters. In this sense, DEF decreases for dosimeters containing large and segregated particles. The influence of nanoparticle size-position is more noticeable for dosimeters irradiated with higher beam energies, and dosimeters containing large and segregated particles become less sensitive than pure alanine (DEF < 1). Conclusions: ESR dosimetry gives the DEF in a medium containing metal nanoparticles, although particle concentration, size, and position are closely related in the system. Because this is also the case as in many real systems of materials containing inorganic nanoparticles, ESR is a valuable tool for

  4. Modeling of Body Weight Metrics for Effective and Cost-Efficient Conventional Factor VIII Dosing in Hemophilia A Prophylaxis

    Directory of Open Access Journals (Sweden)

    Alanna McEneny-King

    2017-10-01

    Full Text Available The total body weight-based dosing strategy currently used in the prophylactic treatment of hemophilia A may not be appropriate for all populations. The assumptions that guide weight-based dosing are not valid in overweight and obese populations, resulting in overdosing and ineffective resource utilization. We explored different weight metrics including lean body weight, ideal body weight, and adjusted body weight to determine an alternative dosing strategy that is both safe and resource-efficient in normal and overweight/obese adult patients. Using a validated population pharmacokinetic model, we simulated a variety of dosing regimens using different doses, weight metrics, and frequencies; we also investigated the implications of assuming various levels of endogenous factor production. Ideal body weight performed the best across all of the regimens explored, maintaining safety while moderating resource consumption for overweight and obese patients.

  5. Pharmacokinetics and pharmacodynamics of multiple doses of BG00010, a neurotrophic factor with anti-hyperalgesic effects, in patients with sciatica.

    Science.gov (United States)

    Okkerse, Pieter; Hay, Justin L; Versage, Eve; Tang, Yongqiang; Galluppi, Gerald; Ravina, Bernard; Verma, Ajay; Williams, Leslie; Aycardi, Ernesto; Groeneveld, Geert Jan

    2016-07-01

    BG00010 is a protein in the glial cell line-derived neurotrophic factor (GDNF) family. It is a selective ligand for the GDNF family receptor alpha-3 (GFRα3) co-receptor that normalizes cellular changes resulting from damage or disease, and potentially alleviates neuropathic pain. The main objectives of this study were to evaluate the pharmacokinetic and safety profiles and to determine the effects on pain of ascending doses of intravenous injections of BG00010 in patients with sciatica. This was a randomized, blinded, placebo-controlled multiple-dose study in subjects with sciatica. In Part I (16 patients), four IV dose levels were examined (50, 150, 400, 800 μg kg(-1) ) and in Part II (12 patients), three dose levels were examined (400, 600 and 1200 μg kg(-1) ). Safety and efficacy assessments were used as endpoints. The BG00010 concentration-time data indicated relatively low inter-patient variability and there was a dose-dependent (not dose-proportional) increase in serum exposure from 150 to 1200 μg kg(-1) . The effective half-life was between 40 and 60 h. The most frequently occurring adverse events (AEs) reported by patients receiving BG00010 were headache (67-83%), feeling hot (50-100%), and pruritus (42-67%). Most AEs were mild; no serious AEs or AEs leading to discontinuation occurred. Higher dose regimens of BG00010 resulted in greater pain reduction than placebo or lower dose regimens, although a clear dose-response relationship was not seen. The pharmacokinetic profile of BG00010 was characterized by low intra-patient variability. These data from a small sample suggest that BG00010 may have a benefit for patients with sciatica. © 2016 The British Pharmacological Society.

  6. Assessment of individual dose utilization vs. physician prescribing recommendations for recombinant activated factor VII (rFVIIa) in paediatric and adult patients with congenital haemophilia and alloantibody inhibitors (CHwI): the Dosing Observational Study in Hemophilia (DOSE).

    Science.gov (United States)

    Gruppo, R A; Kessler, C M; Neufeld, E J; Cooper, D L

    2013-07-01

    Recent data from the Dosing Observational Study in Hemophilia diary study has described home treatment with recombinant activated factor VII (rFVIIa) in congenital haemophilia with inhibitors (CHwI). The current analysis compares prescribed and patient/caregiver-reported rFVIIa administration in paediatric and adult CHwI patients in this study. Patients with ≥ 4 bleeding episodes within a 3-month period prescribed rFVIIa as first-line therapy for bleeding episodes were eligible. Patients/caregivers completed a diary for ≥ 90 days or until the patient experienced four bleeds. Initial, total and mean rFVIIa doses reported for each bleeding episode were calculated and compared with the physician-prescribed doses. Of 52 enrolled patients (25 children; 27 adults), 39 (75%) completed the study. Children and adults had similar mean durations of bleeding episodes. Both patient groups were administered higher initial rFVIIa doses for joint bleeds than prescribed: median (range) 215.2 (74.1-400.0) mcg kg(-1) vs. 200.0 (61.0-270.0) mcg kg(-1) for children, and 231.3 (59.3-379.7) mcg kg(-1) vs. 123.0 (81.0-289.0) mcg kg(-1) for adults. The median infused dose for joint bleeds was higher in adults than children (175.2 vs. 148.0 mcg kg(-1) ), but children received significantly more doses per joint bleed than adults (median 6.5 vs. 3.0). The median total dose per joint bleed was higher in children than adults (1248.7 vs. 441.6). For children and adults, both initial and additional doses administered for bleeds were higher than prescribed. Children received higher total doses per bleed due to an increased number of infusions per bleed. © 2013 John Wiley & Sons Ltd.

  7. Objective factors affecting the image quality of low-dose cranial CT of infant

    International Nuclear Information System (INIS)

    Xie Na; Gan Yungen; Wang Hongwei; Zeng Hongwu; Cao Weiguo; Sun Longwei

    2010-01-01

    Objective: To investigate the objective factors that affect the image quality of infant cranial CT using different mAs. Materials and Methods: Ninety infants were divided into three groups randomly. The maximum anteroposterior diameter (MAPD) of skull of each infant was measured. Three reference levels, cerebellar, basal ganglia and centrum semiovale levels were selected respectively. Only one level was studied in each group and scanned with 150, 100 and 80 mAs. The subjective quality grade and the objective noise of all images were recorded and analysed statistically. Results: The average MAPD of ninety patients was (148.0±17.4) mm. On the cerebellar level, the subjective quality grade was lower than the other two levels, which were 6.3%, 9.4% and 22.9% respectively when mAs were 150, 100 and 80 mAs. Both quality grade of image and objective noise were significantly correlated with MAPD. Conclusions: The inherent high noise of cerebellar level and MAPD were the objective factors that affect the image quality of low-dose cranial CT of infant. (authors)

  8. Development and application of a complex numerical model and software for the computation of dose conversion factors for radon progenies.

    Science.gov (United States)

    Farkas, Árpád; Balásházy, Imre

    2015-04-01

    A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. The relations between the quantity of milligram hours and doses to points A and B in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Martins, H.L.; Albuquerque, L.F.

    1987-01-01

    This paper shows that the mathematic relation used in doses prescription systems of gynecologic brachytherapy is precarious and it only be used in isolated cases, with the owing restrictions. The material, methods and the results are cited, analysing the dose ratio in function of some variables as: ovoid load, uterine probe curvature, etc. (C.G.C.) [pt

  10. Factors influencing the success of radio-iodine dose in the treatment of Graves disease: one year outcome

    International Nuclear Information System (INIS)

    Kamoun, T.; Sfar, R.; Regaieg, H.; Toumi, A.; Zanzouri, H.; Nouira, M.; Ben Fredj, M.; Ayachi, N.; Chatti, K.; Guezguez, M.; Essabbah, H.; Sakly, N.

    2015-01-01

    Full text of publication follows. Aim: radioiodine ( 131 I) is increasingly used as the definitive treatment of Graves disease (GD). Many factors influence the curative effects of the 131 I, thus there are some difficulties to define the optimal dose of 131 I for the treatment of GD. The purpose of our study is to evaluate the factors influencing the success rate in patients having GD and treated with radioiodine dose modulated by thyroid mass. Materials and methods: this is a prospective study of 86 patients (aged 43 ± 11, 58 women and 28 men) treated for Graves disease by radioiodine during the year 2011 in Nuclear Medicine department CHU Sahloul, Sousse. Radioiodine dose are modulated by thyroid mass: 370 MBq, 444 MBq and 555 MBq respectively for mass strictly less than 30 g, between 30 g and 40 g and greater than to 40 g. Some patients received more than 555 MBq for other causes to reach hypothyroidism precociously. The thyroid function outcome (hyperthyroidism or euthyroidism/hypothyroidism) was verified 6 months and 1 year after 131 I treatment. Patient gender, age, ophthalmopathy, thyroid size, antithyroid drugs used prior to 131 I treatment and anti-TSH receptor antibodies (TRAb), anti-thyroid peroxidase antibodies (ATPO) and anti-thyroglobulin antibodies (ATG) plasma concentrations before 131 I treatment were studied as potential interference factors for 131 I treatment success. Results: Thirty patients received 370 MBq, 29 received 444 MBq, 14 received 555 MBq and 13 more than 555 MBq. Outcome after treatment was determined in a total of 66 patients at 6 months and 63 at one year. Post-therapy follow-up revealed that treatment failed in 29% of the patients at 6 months and in 20% of patients at one year. No correlation was noted between the outcome of treatment and age, sex, ophthalmopathy, antithyroid drugs taking and ATG titer. A significant correlation was noted between the disease outcome at one year and TRAb titer: High TRAb levels are associated

  11. Induction of factors of apoptosis in human tumor cells by low doses of radon

    International Nuclear Information System (INIS)

    Soto, J.; Martin, A.; Cos, S.; Gonzalez-Lamuno, D.

    1997-01-01

    The possibility of modification of genes related with apoptosis in tumor cells calls for a multidisciplinary experiment which describes the conditions and characteristics of such modification. In this work low radiation doses from radon were used in the irradiation of tumor cells of human mammary glands. After irradiation, the cells incubate for three days, after which they are counted and a total extraction of ARN is effected. Through bimolecular techniques, inverse transcription and polymerase chain reaction, the expression of genes involved in apoptosis is studied. The results found indicate that, in the cell line denominated MCF-7, the genes bcl-2, bcl-xL and bax are expressed. In the irradiated cells, the levels of expression of bcl x increase with respect to the control and induce the expression of the form bcl-xS, the protein of which induces apoptosis

  12. Uncertainty of the thyroid dose conversion factor for inhalation intakes of 131I and its parametric uncertainty

    International Nuclear Information System (INIS)

    Harvey, R. P.; Hamby, D. M.; Palmer, T. S.

    2006-01-01

    Inhalation exposures of 131 I may occur in the physical form of a gas as well as a particulate. The physical characteristics pertaining to these different types of releases influence the intake and subsequent dose to an exposed individual. The thyroid dose received is influenced by the route through which 131 I enters the body and its subsequent clearance, absorption and movement throughout the body. The radioactive iodine taken up in the gas-exchange tissues is cleared to other tissues or absorbed into the bloodstream of the individual and transferred to other organs. Iodine in the circulatory system is then taken up by the thyroid gland with resulting dose to that tissue. The magnitude of and uncertainty in the thyroid dose is important to the assessment of individuals exposed to airborne releases of radioiodine. Age- and gender-specific modelling parameters have resulted in significant differences between gas uptake, particulate deposition and inhalation dose conversion factors for each age and gender group. Inhalation dose conversion factors and their inherent uncertainty are markedly affected by the type of iodine intake. These differences are expected due to the modelling of particulate deposition versus uptake of gas in the respiratory tract. Inhalation dose estimates via iodine gases are very similar and separate classifications may not be necessarily based on this assessment. (authors)

  13. Pathology consultation on anticoagulation monitoring: factor X-related assays.

    Science.gov (United States)

    Wool, Geoffrey D; Lu, Chuanyi M

    2013-11-01

    To review various anticoagulation therapies and related laboratory monitoring issues, with a focus on factor X-related chromogenic assays. A case-based approach is used to review pertinent published literatures and product inserts of anticoagulation drugs and to look back on clinical use of factor X-related chromogenic assays. The number of anticoagulants available to clinicians has increased greatly in the past decade. Whether and how these anticoagulants should be monitored are areas of uncertainty for clinicians, which can lead to misuse of laboratory assays and suboptimal patient management. Factor X-related assays are of particular concern because of the similar and often confusing test names. Based on a common clinical case scenario and literature review regarding anticoagulant monitoring, an up-to-date discussion and review of the various factor X-related assays are provided, focusing on the differences in test designs and clinical utilities between the chromogenic anti-Xa and chromogenic factor X activity assays. Anticoagulation therapy and related laboratory monitoring are rapidly evolving areas of clinical practices. A good knowledge of relevant laboratory assays and their clinical applications is necessary to help optimize patient care.

  14. Activin- and Nodal-related factors control antero-posterior patterning of the zebrafish embryo.

    Science.gov (United States)

    Thisse, B; Wright, C V; Thisse, C

    2000-01-27

    Definition of cell fates along the dorso-ventral axis depends on an antagonistic relationship between ventralizing transforming growth factor-beta superfamily members, the bone morphogenetic proteins and factors secreted from the dorsal organizer, such as Noggin and Chordin. The extracellular binding of the last group to the bone morphogenetic proteins prevents them from activating their receptors, and the relative ventralizer:antagonist ratio is thought to specify different dorso-ventral cell fates. Here, by taking advantage of a non-genetic interference method using a specific competitive inhibitor, the Lefty-related gene product Antivin, we provide evidence that cell fate along the antero-posterior axis of the zebrafish embryo is controlled by the morphogenetic activity of another transforming growth factor-beta superfamily subgroup--the Activin and Nodal-related factors. Increasing antivin doses progressively deleted posterior fates within the ectoderm, eventually resulting in the removal of all fates except forebrain and eyes. In contrast, overexpression of activin or nodal-related factors converted ectoderm that was fated to be forebrain into more posterior ectodermal or mesendodermal fates. We propose that modulation of intercellular signalling by Antivin/Activin and Nodal-related factors provides a mechanism for the graded establishment of cell fates along the antero-posterior axis of the zebrafish embryo.

  15. Relationship of time--dose factors to tumor control and complications in the treatment of Cushing's disease by irradiation

    International Nuclear Information System (INIS)

    Aristizabal, S.; Caldwell, W.L.; Avila, J.; Mayer, E.G.

    1977-01-01

    The records of the Radiotherapy Division of the Radiology Department of Vanderbilt University Hospital were reviewed for the period 1952 to 1970. During those 19 years 45 patients with a well-documented diagnosis of Cushing's disease were treated initially by external irradiation of the pituitary. All of the patients were treated with megavoltage equipment using photons. When the results of irradiation are compared against total doses of radiation, it is evident that the control rate is unsatisfactory at doses less than 4000 rad and the maximum benefits of irradiation are evident in the 4500 to 5000 rad dose range. It is also clear that the complication rate increases as the dose exceeds 4800 rad. If the various treatment regimens of irradiation are converted to ''equivalent'' doses by the Nominal Standard Dose (NSD) or Time-Dose-Fractionation (TDF) methods, the relationship between ''dose'' and efficacy of therapy and complications is demonstrated. In order to reduce the possibility of treatment-related morbidity, the use of three or more small (4 x 4 cm) treatment portals or rotational techniques is recommended to a pituitary dose of 4600 to 5000 rad treating 5 days a week for 5 to 6 weeks

  16. Estimated doses related to 222Rn concentration in bunker for radiotherapy and storage of radioisotopes

    International Nuclear Information System (INIS)

    Mestre, Freddy; Carrizales-Silva, Lila; Sajo-Bohus, Laszlo; Diaz, Cruz

    2013-01-01

    It was done a survey in radiotherapy services underground hospitals and clinics of Venezuela and Paraguay in order to estimate the concentrations of radon and its possible consequences on worker occupational exposure. Passive dosimeters were used to assess nuclear traces (NTD type CR-39®). The concentration of 222 Rn is determined based on the density of traces using the calibration coefficient of 1 tr/cm 2 equivalent to 0,434 Bqm -3 per month of exposure. Assuming the most likely environmental conditions and the dose conversion factor equal to 9.0 x 10 -6 mSv h -1 by Bqm -3 , it was determined the average values and estimated the possible risks to health that are on average 3.0 mSva -1 and 150 micro risk cancer

  17. Skin dose rate conversion factors after contamination with radiopharmaceuticals: influence of contamination area, epidermal thickness and percutaneous absorption

    International Nuclear Information System (INIS)

    Covens, P; Berus, D; Caveliers, V; Struelens, L; Vanhavere, F; Verellen, D

    2013-01-01

    Skin contamination with radiopharmaceuticals can occur during biomedical research and daily nuclear medicine practice as a result of accidental spills, after contact with bodily fluids of patients or by inattentively touching contaminated materials. Skin dose assessment should be carried out by repeated quantification to map the course of the contamination together with the use of appropriate skin dose rate conversion factors. Contamination is generally characterised by local spots on the palmar surface of the hand and complete decontamination is difficult as a result of percutaneous absorption. This specific issue requires special consideration as to the skin dose rate conversion factors as a measure for the absorbed dose rate to the basal layer of the epidermis. In this work we used Monte Carlo simulations to study the influence of the contamination area, the epidermal thickness and the percutaneous absorption on the absorbed skin dose rate conversion factors for a set of 39 medical radionuclides. The results show that the absorbed dose to the basal layer of the epidermis can differ by up to two orders of magnitude from the operational quantity H p (0.07) when using an appropriate epidermal thickness in combination with the effect of percutaneous absorption. (paper)

  18. The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room

    Energy Technology Data Exchange (ETDEWEB)

    Harding, L K; Harding, N J; Warren, H; Mills, A; Thomson, W H [Dudley Road Hospital, Birmingham (UK)

    1990-01-01

    The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room was assessed at 5 min intervals by observing the seating arrangement. The total radiation dose to each person was calculated, using fixed values of dose rate per 100 MBq activity for radionuclides, and applying the inverse square law. Radioactive decay and attenuation effects due to intervening persons were also taken into account. The median radiation doses to accompanying nurses, relatives and other patients were 2.3, 2.0 and 0.2 {mu}Sv with maximum values of 17, 33 and 5 {mu}Sv respectively. In all cases, the radiation dose received by patients was less than 0.2% of the radiation dose resulting from their own investigation. Also, the maximum radiation dose received by an accompanying norse or friend was less than 1% of their appropriate annual dose limit. Similar values were obtained with calculations based on a 15 min time interval. The radiation doses received by those in a nuclear medicine department waiting room are small, and separate waiting room facilities for radioactive patients are unnecessary. (author).

  19. Cancer-related fatigue: Mechanisms, risk factors, and treatments

    Science.gov (United States)

    Bower, Julienne E.

    2015-01-01

    Fatigue is one of the most common and distressing side effects of cancer and its treatment, and may persist for years after treatment completion in otherwise healthy survivors. Cancer-related fatigue causes disruption in all aspects of quality of life and may be a risk factor for reduced survival. The prevalence and course of fatigue in cancer patients has been well characterized, and there is growing understanding of underlying biological mechanisms. Inflammation has emerged as a key biological pathway for cancer-related fatigue, with studies documenting links between markers of inflammation and fatigue before, during, and particularly after treatment. There is considerable variability in the experience of cancer-related fatigue that is not explained by disease- or treatment-related characteristics, suggesting that host factors may play an important role in the development and persistence of this symptom. Indeed, longitudinal studies have begun to identify genetic, biological, psychosocial, and behavioral risk factors for cancer-related fatigue. Given the multi-factorial nature of cancer-related fatigue, a variety of intervention approaches have been examined in randomized controlled trials, including physical activity, psychosocial, mind-body, and pharmacological treatments. Although there is currently no gold standard for treating fatigue, several of these approaches have shown beneficial effects and can be recommended to patients. This report provides a state of the science review of mechanisms, risk factors, and interventions for cancer-related fatigue, with a focus on recent longitudinal studies and randomized trials that have targeted fatigued patients. PMID:25113839

  20. Factors Related to Job Satisfaction of Information Technology Professionals

    Directory of Open Access Journals (Sweden)

    İbrahim Halil SEYREK

    2016-01-01

    Full Text Available Job satisfaction of employees in any type of organization is important both for the employee and for the organization he/she works for. There are several factors researchers studied that are related to employee satisfaction. Even though there are several common factors for the job satisfaction of employees, there can be differences based on the personal and job characteristics. Information Technology (IT workers are important for current information economy and therefore factors related to their job satisfaction is an important research topic. In this study, based on survey data collected from 455 IT workers from different industries, the factors related to IT worker job satisfaction are investigated. As a result of analyses, it was found that demographic factors like gender, sector (public vs. private, work experience, and wage are not related to the job satisfaction of the worker. On the other hand, the results show that feel of belonging, feel of acceptance, job autonomy, burnout, role clarity and fairness of rewards are factors that affect job satisfaction.

  1. Absolute and relative dose-surface and dose-volume histograms of the bladder: which one is the most representative for the actual treatment?

    International Nuclear Information System (INIS)

    Hoogeman, Mischa S; Peeters, Stephanie T H; Bois, Josien de; Lebesque, Joos V

    2005-01-01

    The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment

  2. Radioactivity content of Shiraz water supplies and its related effective dose

    International Nuclear Information System (INIS)

    Mehdizadeh, S.; Derakhshan, Sh.

    2004-01-01

    We are exposed naturally to ionizing radiation from cosmic rays and natural radionuclides in the air, ground, food and drinking water. When invested, naturally and radionuclides are distributed among body organs. The average concentrations of naturally occurring radionuclides in drinking water are used to estimated the annual effective dose equivalents. In this work, during October of 2002 to October of 2003, 37 samples from 29 different wells and Doroodzan dam were gathered in winter and summer and the gross Alfa and Beta, total uranium and Ra-226 activity in each sample were determined. The activity of Ra-226 was measured by Radon Emanation method and total uranium was determined using laser Fluorimetry. The mean concentration of Ra-226 was higher in summer but the uranium had higher concentration in winter. The mean concentration of Ra-226 and Uranium were 15.72±1.12 mBq.1 -1 and 9.44±1.14μg.1 -1 in winter ±μ and 29.46 2.18 mBq.1 -1 and 7.37 1.1 g.1 -1 in summer respectively. The average annual effective doses (Ra-226) of different age groups (Adults, children and infants) were equal to 2.37± 0.22, 5.42 ±0.43, 2.66±0.24, mSv.y 1 -1 and 0.136±0.02, 0.18±0.027 and 0.171±0.026 mSv.y -1 due to existence of uranium in drinking water. The results of this survey showed that the radioactive concentration of the radionuclides and their related effective doses are in the normal range and permissible levels. These results are comparable with those found by Atomic Energy Organization of Iran but different with the results of the limited project done during 1999 at Shiraz

  3. Stereotactic targeting and dose verification for age-related macular degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Gertner, Michael; Chell, Erik; Pan, Kuang-Hung; Hansen, Steve; Kaiser, Peter K.; Moshfeghi, Darius M. [Oraya Therapeutics, Inc., Newark, California 94560 (United States); Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, Ohio 44915 (United States); Department of Ophthalmology, Stanford University, Stanford, California 94305 (United States)

    2010-02-15

    Purpose: Validation of the targeting and dose delivery of the IRay low voltage age-related macular degeneration treatment system. Methods: Ten human cadaver eyes were obtained for this study and mounted in the IRay system. Using gel and vacuum, an I-Guide immobilization device was coupled to the eyes and radiochromic film was affixed to the posterior aspect of the globes. Three narrow x-ray beams were delivered through the pars plana to overlap on the predicted nominal fovea. A needle was placed through the center of the film's beam spot and into the eye to register the film and the inner retina. The process was performed three times for each of the ten eyes (30 simulated treatments; 90 individual beams). The globes were dissected to assess the targeting accuracy by measuring the distances from the needles to the fovea. The dose to the fovea was calculated from the radiochromic film. Results: X-ray targeting on the retina averaged 0.6{+-}0.4 mm from the fovea. Repeated treatments on the same eye showed a reproducibility of 0.4{+-}0.4 mm. The optic nerve was safely avoided, with the 90% isodose edge of the beam spot between 0.4 and 2.6 mm from the edge of the optic disk. Measured dose matched that prescribed. Conclusions: This study provides confidence that the IRay, with an average accuracy of 0.6 mm and a precision of 0.4 mm, can reliably treat most AMD lesions centered on the fovea. With the exception of motion, all sources of error are included.

  4. Analysis of related risk factors for pancreatic fistula after pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Qi-Song Yu

    2016-08-01

    Full Text Available Objective: To explore the related risk factors for pancreatic fistula after pancreaticoduodenectomy to provide a theoretical evidence for effectively preventing the occurrence of pancreatic fistula. Methods: A total of 100 patients who were admitted in our hospital from January, 2012 to January, 2015 and had performed pancreaticoduodenectomy were included in the study. The related risk factors for developing pancreatic fistula were collected for single factor and Logistic multi-factor analysis. Results: Among the included patients, 16 had pancreatic fistula, and the total occurrence rate was 16% (16/100. The single-factor analysis showed that the upper abdominal operation history, preoperative bilirubin, pancreatic texture, pancreatic duct diameter, intraoperative amount of bleeding, postoperative hemoglobin, and application of somatostatin after operation were the risk factors for developing pancreatic fistula (P<0.05. The multi-factor analysis showed that the upper abdominal operation history, the soft pancreatic texture, small pancreatic duct diameter, and low postoperative hemoglobin were the dependent risk factors for developing pancreatic fistula (OR=4.162, 6.104, 5.613, 4.034, P<0.05. Conclusions: The occurrence of pancreatic fistula after pancreaticoduodenectomy is closely associated with the upper abdominal operation history, the soft pancreatic texture, small pancreatic duct diameter, and low postoperative hemoglobin; therefore, effective measures should be taken to reduce the occurrence of pancreatic fistula according to the patients’ own conditions.

  5. Youth suicide attempts and the dose-response relationship to parental risk factors: a population-based study

    DEFF Research Database (Denmark)

    Christiansen, E; Goldney, R D; Beautrai, A L

    2011-01-01

    BACKGROUND: There is a lack of specific knowledge about the dose-response effect of multiple parental risk factors for suicide attempts among children and adolescents. The aim of this study was to determine the dose-response effect of multiple parental risk factors on an offspring's risk for suic......BACKGROUND: There is a lack of specific knowledge about the dose-response effect of multiple parental risk factors for suicide attempts among children and adolescents. The aim of this study was to determine the dose-response effect of multiple parental risk factors on an offspring's risk...... for suicide attempt.MethodWe designed a population-based two-generation nested case-control study and used Danish register data. A population of 403 431 individuals born between 1983 and 1989 was sampled. Among these, 3465 (0.8%) were registered as having had a suicide attempt. Twenty controls were matched...... to each case and a link to the offspring's biological parents was established. RESULTS: There was a dose-response relationship between the number of exposures and the risk of suicide attempts, with the increased risk seeming to be a multiplicative effect. Parental suicide, suicide attempt, psychiatric...

  6. Study of factors controlling exposure dose and image quality of C-arm in operation room according to detector size of it (Mainly L-Spine AP study)

    Energy Technology Data Exchange (ETDEWEB)

    Chui, Sung Hyun; Jo, Hwang Woo [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of); Chun, Woon Kwan; Song, Ha Jin [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Choi, Eun Jin [Dept. of Public Health and Medicine, Dongshin University, Naju (Korea, Republic of)

    2015-02-15

    does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

  7. The Impact of Genetic and Non-Genetic Factors on Warfarin Dose Prediction in MENA Region: A Systematic Review.

    Science.gov (United States)

    Bader, Loulia Akram; Elewa, Hazem

    2016-01-01

    Warfarin is the most commonly used oral anticoagulant for the treatment and prevention of thromboembolic disorders. Pharmacogenomics studies have shown that variants in CYP2C9 and VKORC1 genes are strongly and consistently associated with warfarin dose variability. Although different populations from the Middle East and North Africa (MENA) region may share the same ancestry, it is still unclear how they compare in the genetic and non-genetic factors affecting their warfarin dosing. To explore the prevalence of CYP2C9 and VKORC1 variants in MENA, and the effect of these variants along with other non-genetic factors in predicting warfarin dose. In this systematic review, we included observational cross sectional and cohort studies that enrolled patients on stable warfarin dose and had the genetics and non-genetics factors associated with mean warfarin dose as the primary outcome. We searched PubMed, Medline, Scopus, PharmGKB, PHGKB, Google scholar and reference lists of relevant reviews. We identified 17 studies in eight different populations: Iranian, Israeli, Egyptian, Lebanese, Omani, Kuwaiti, Sudanese and Turkish. Most common genetic variant in all populations was the VKORC1 (-1639G>A), with a minor allele frequency ranging from 30% in Egyptians and up to 52% and 56% in Lebanese and Iranian, respectively. Variants in the CYP2C9 were less common, with the highest MAF for CYP2C9*2 among Iranians (27%). Variants in the VKORC1 and CYP2C9 were the most significant predictors of warfarin dose in all populations. Along with other genetic and non-genetic factors, they explained up to 63% of the dose variability in Omani and Israeli patients. Variants of VKORC1 and CYP2C9 are the strongest predictors of warfarin dose variability among the different populations from MENA. Although many of those populations share the same ancestry and are similar in their warfarin dose predictors, a population specific dosing algorithm is needed for the prospective estimation of warfarin

  8. Minimal erythema dose and minimal melanogenesis dose relate better to objectively measured skin type than to Fitzpatricks skin type

    DEFF Research Database (Denmark)

    Wulf, Hans Christian; Philipsen, Peter A; Ravnbak, Mette H

    2010-01-01

    Fitzpatrick skin type (FST I-IV) is a subjective expression of ultraviolet (UV) sensitivity based on erythema and tanning reactivity after a single exposure. Pigment protection factor (PPF) is an objective measurement of skin sensitivity in all skin types after a single exposure....

  9. Cancer-related fatigue--mechanisms, risk factors, and treatments.

    Science.gov (United States)

    Bower, Julienne E

    2014-10-01

    Fatigue is one of the most common adverse effects of cancer that might persist for years after treatment completion in otherwise healthy survivors. Cancer-related fatigue causes disruption in all aspects of quality of life and might be a risk factor of reduced survival. The prevalence and course of fatigue in patients with cancer have been well characterized and there is growing understanding of the underlying biological mechanisms. Inflammation seems to have a key role in fatigue before, during, and after cancer-treatment. However, there is a considerable variability in the presentation of cancer-related fatigue, much of which is not explained by disease-related or treatment-related characteristics, suggesting that host factors might be important in the development and persistence of this symptom. Indeed, longitudinal studies have identified genetic, biological, psychosocial, and behavioural risk factors associated with cancer-related fatigue. Although no current gold-standard treatment for fatigue is available, a variety of intervention approaches have shown beneficial effects in randomized controlled trials, including physical activity, psychosocial, mind-body, and pharmacological treatments. This Review describes the mechanisms, risk factors, and possible interventions for cancer-related fatigue, focusing on recent longitudinal studies and randomized trials that have targeted fatigued patients.

  10. Clinicopathological Analysis of Factors Related to Colorectal Tumor Perforation

    OpenAIRE

    Medina-Arana, Vicente; Martínez-Riera, Antonio; Delgado-Plasencia, Luciano; Rodríguez-González, Diana; Bravo-Gutiérrez, Alberto; Álvarez-Argüelles, Hugo; Alarcó-Hernández, Antonio; Salido-Ruiz, Eduardo; Fernández-Peralta, Antonia M.; González-Aguilera, Juan J.

    2015-01-01

    Abstract Colorectal tumor perforation is a life-threatening complication of this disease. However, little is known about the anatomopathological factors or pathophysiologic mechanisms involved. Pathological and immunohistochemical analysis of factors related with tumoral neo-angiogenesis, which could influence tumor perforation are assessed in this study. A retrospective study of patients with perforated colon tumors (Group P) and T4a nonperforated (controls) was conducted between 2001 and 20...

  11. Estimates of Health Detriments and Tissue Weighting Factors for Hong Kong Populations from Low Dose, Low Dose Rate and Low LET Ionising Radiation Exposure

    International Nuclear Information System (INIS)

    Lee, S.K.

    1998-01-01

    The total health detriments and the tissue weighting factors for the Hong Kong populations from low dose, low dose rate and low LET ionising radiation exposure are obtained according to the methodology recommended in ICRP Publication 60. The probabilities of fatal cancers for the general (ages 0-90) and working (ages 20-64) populations due to lifetime exposure at low dose and low dose rate are 4.9 x 10 -2 Sv -1 and 3.6 x 10 -2 Sv -1 respectively, comparing with the ICRP 60 estimates of 5.0 x 10 -2 Sv -1 and 4.0 x 10 -2 Sv -1 . The corresponding total health detriments for the general and working populations are 6.9 x 10 -2 Sv -1 and 4.9 x 10 -2 Sv -1 respectively comparing with the ICRP 60 estimates of 7.3 x 10 -2 Sv -1 and 5.6 x 10 -2 Sv -1 . Tissue weighting factors for the general population are 0.01 (bone surface and skin), 0.02 (liver, oesophagus and thyroid), 0.04 (bladder and breast), 0.08 (remainder), 0.10 (stomach), 0.11 (bone marrow), 0.15 (colon), 0.19 (lung) and 0.21 (gonads) and for the working population are 0.01 (bone surface and skin), 0.03 (liver, oesophagus and thyroid), 0.04 (breast), 0.06 (remainder), 0.07 (bladder), 0.08 (colon), 0.14 (bone marrow and stomach), 0.16 (lung) and 0.20 (gonads). (author)

  12. Production of humoral factors that stimulate spleen colony-forming units in mice irradiated with moderate doses of X rays

    International Nuclear Information System (INIS)

    Grande, T.; Gonzalez, J.; Tejero, C.; Maganto, G.; Bueren, J.A.

    1990-01-01

    The production of humoral factors that stimulate spleen colony-forming units (CFU-S) has been studied in irradiated mice using an in vivo diffusion chamber assay. The experiments show that a significant release of factors that stimulate CFU-S takes place in the first few days after irradiation with moderate doses of 1.5 or 5 Gy. In contrast, the release of significant amounts of these humoral factors was not seen in animals irradiated with either low (0.75 Gy) or high (10 Gy) doses of X rays. The correlation observed between the production of factors that stimulate the CFU-S and the hemopoietic regeneration kinetics of the irradiated mice suggests that these factors represent part of the physiological regulators controlling the proliferation of CFU-S

  13. Single-dose relative biological effectiveness and toxicity studies under conditions of hypothermia and hyperbaric oxygen

    International Nuclear Information System (INIS)

    Hering, E.R.; Blekkenhorst, G.; Harrison, G.G.; Morrell, D.; Korrubel, J.; Gregory, A.; Phillips, J.; Manca, V.; Sealy, R.; Cape Town Univ.

    1986-01-01

    An approach to using hyperbaric oxygen with radiation in a clinical situation has been described in the preceding paper in this issue. To ascertain whether there might be a change in the relative biological effectiveness of radiation on normal mammalian tissue treated under conditions of hypothermia and hyperbaric oxygen, the acute reaction to radiation of pig skin was studied. A single dose enhancement ratio at the erythema reaction level of 1.4+-0.08 was obtained when compared with irradiation at normal body temperature in air. The authors studied also a series of antioxidant enzymes in rat liver and lung after exposure to hypothermia and hyperbaric oxygen. Enzyme changes were such as to combat oxygen toxicity which might develop as a result of the pre-treatment. (author)

  14. SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, S; Kushima, N; Katsura, K; Tanabe, S; Hayakawa, T; Sakai, H; Yamada, T; Takahashi, H; Abe, E; Wada, S; Aoyama, H [Niigata University, Niigata (Japan)

    2016-06-15

    Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

  15. Factors related to attrition from trauma-focused cognitive behavioral therapy.

    Science.gov (United States)

    Wamser-Nanney, Rachel; Steinzor, Cazzie E

    2017-04-01

    Attrition from child trauma-focused treatments such as Trauma-Focused Cognitive Behavioral Therapy (TF-CBT) is common; yet, the factors of children who prematurely terminate are unknown. The aim of the current study was to identify risk factors for attrition from TF-CBT. One hundred and twenty-two children (ages 3-18; M=9.97, SD=3.56; 67.2% females; 50.8% Caucasian) who received TF-CBT were included in the study. Demographic and family variables, characteristics of the trauma, and caregiver- and child-reported pretreatment symptoms levels were assessed in relation to two operational definitions of attrition: 1) clinician-rated dropout, and 2) whether the child received an adequate dose of treatment (i.e., 12 or more sessions). Several demographic factors, number of traumatic events, and children's caregiver-rated pretreatment symptoms were related to clinician-rated dropout. Fewer factors were associated with the adequate dose definition. Child Protective Services involvement, complex trauma exposure, and child-reported pretreatment trauma symptoms were unrelated to either attrition definition. Demographics, trauma characteristics, and level of caregiver-reported symptoms may help to identify clients at risk for premature termination from TF-CBT. Clinical and research implications for different operational definitions and suggestions for future work will be presented. Published by Elsevier Ltd.

  16. Low dose radiation in the treatment of HIV related benign lymphoepithelial lesions of the parotid gland

    International Nuclear Information System (INIS)

    Tchelebi, Anca E.; Ming Teng; Moscatello, Augustine; Moorthy, Chitti R.; Kaufmann, Thomas; Ahmed, Tauseef

    1996-01-01

    Purpose/Objective: To determine the effectiveness of Radiation Therapy (RT) in the treatment of human immunodeficiency virus (HIV) related benign lymphoepithelial (BLL) of the parotid gland. Materials and Methods: The records of 16 patients treated between 1991 to 1995 with BLL were retrospectively reviewed. Three patients had bilateral disease, thus 19 parotid glands were radiated. Only (2(16)) had AIDS. Virtually all patients were on antiretroviral therapy. There were 11 males and 5 females. The median age was 38 years (range 31 to 58 years). The median duration of parotid enlargement was 1.5 years (range 1 month to 6 years). All patients had biopsy prior to treatment. Histopathology revealed two patterns: solid or cystic. Patient were treated using electron beam RT. The beam energy was determined by computed transaxial tomography. The median dose delivered was 1000 cGy in 5 fractions over 5 days (range 600 cGy to 2160 cGy in daily fractions ranging from 180 cGy to 200 cGy). Results: Six parotid glands achieved a complete response (CR), 5 a partial response (PR), while 8 were non-responders (NR). Our overall response rate was therefore 58% Of the NR's, 3 patients were re-treated. Two achieved a PR, one was an NR. Toxicity was minimal and limited to mild xerostomia. Conclusion: RT in patients with HIV related BLL is well tolerated. Our preliminary results show that while this modality of treatment has marked activity in the solid pattern. Higher doses may be required for large lesions or cystic in nature

  17. Factors influencing changes in levels of radiation doses received by patients during gastroduodenal series procedures in the Hospital Dr. Max Peralta de Cartago

    International Nuclear Information System (INIS)

    Guzman Campos, Jeremy; Vargas Navarro, Jonnathan

    2009-01-01

    A measurement was made of the number of radiation doses emitted by fluoroscopy equipment used in Hospital Dr. Max Peralta, specifically at the Centro de Deteccion de Cancer Gastrico. The analysis has included the factors could be influencing on increase of the total dose to the patient, by means of indicators that directly affect the unnecessary increase in dose, such as: the procedure, sequences of images, indicators of dosage levels, varying conditions of actual studies, variations dose levels and production process factors. [es

  18. Radon in indoor air of primary schools: determinant factors, their variability and effective dose.

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João; Moreira, André; de Oliveira Fernandes, Eduardo; Pereira, Alcides

    2016-04-01

    Radon is a radioactive gas, abundant in granitic areas, such as in the city of Porto at the north-east of Portugal. This gas is a recognized carcinogenic agent, being appointed by the World Health Organization as the leading cause of lung cancer after smoking. The aim of this preliminary survey was to determine indoor radon concentrations in public primary schools, to analyse the main factors influencing their indoor concentration levels and to estimate the effective dose in students and teachers in primary schools. Radon concentrations were measured in 45 classrooms from 13 public primary schools located in Porto, using CR-39 passive radon detectors for about 2-month period. In all schools, radon concentrations ranged from 56 to 889 Bq/m(3) (mean = 197 Bq/m(3)). The results showed that the limit of 100 Bq/m(3) established by WHO IAQ guidelines was exceeded in 92 % of the measurements, as well as 8 % of the measurements exceeded the limit of 400 Bq/m(3) established by the national legislation. Moreover, the mean annual effective dose was calculated as 1.25 mSv/y (ranging between 0.58 and 3.07 mSv/y), which is below the action level (3-10 mSv). The considerable variability of radon concentration observed between and within floors indicates a need to monitor concentrations in several rooms for each floor. A single radon detector for each room can be used, provided that the measurement error is considerably lower than variability of radon concentration between rooms. The results of the present survey will provide useful baseline data for adopting safety measures and dealing effectively with radiation emergencies. In particular, radon remediation techniques should be used in buildings located in the highest radon risk areas of Portugal. The results obtained in the current study concerning radon levels and their variations will be useful to optimize the design of future research surveys.

  19. Efficacy, safety and proper dose analysis of PEGylated granulocyte colony-stimulating factor as support for dose-dense adjuvant chemotherapy in node positive Chinese breast cancer patients

    OpenAIRE

    Zhang, Fan; LingHu, RuiXia; Zhan, XingYang; Li, Ruisheng; Feng, Fan; Gao, Xudong; Zhao, Lei; Yang, Junlan

    2017-01-01

    For high-risk breast cancer patients with positive axillary lymph nodes, dose-dense every-two-week epirubicin/cyclophosphamide-paclitaxel (ddEC-P) regimen is the optimal postoperative adjuvant therapy. However, this regimen is limited by the grade 3/4 neutropenia and febrile neutropenia (FN). There is an urgent need to explore the efficacy, safety and proper dosage of PEGylated granulocyte colony-stimulating factor (PEG-G-CSF) as support for ddEC-P in Chinese breast cancer patients with posit...

  20. Study of dose and relative risk of occupationally exposed individuals in interventional procedures; Estudo de dose e risco relativo de individuos ocupacionalmente expostos em procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Silveira Filho, Jose A.M.; Reis, Charlene O.; Taniguti, Lana T.; Pacifico, Leonardo C.; SaintYves, Thalis L.A.; Mecca, Fernando A., E-mail: ze_augustomsf@hotmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil). Setor de Fisica Medica

    2012-12-15

    This paper estimates the occupational effective dose and the relative risk of leukemia and cancers of the digestive tract mortality through dose study of the most radiosensitive anatomical regions (lens, thyroid, chest and gonads) of the professionals involved in interventional gonad procedures. It was considered a cumulative exposure time of 10,000 hours, which is the occupational exposure time of an IOE in throughout his professional life. It was also considered that they always use Personal Protective Equipment (PPE). Mathematical models derived from epidemiological data contained in the BEIR V and in the IAEA’s TECDOC 870 are used to estimate the relative risk. The results show a significant increase in mortality risk for these types of cancer for individuals occupationally exposed to three different distances from the x-ray beam, and reinforces that radiation protection measures are essential. (author)

  1. Impact of product-related factors on immunogenicity of biotherapeutics.

    Science.gov (United States)

    Singh, Satish Kumar

    2011-02-01

    All protein therapeutics have the potential to be immunogenic. Several factors, including patient characteristics, disease state, and the therapy itself, influence the generation of an immune response. Product-related factors such as the molecule design, the expression system, post-translational modifications, impurities, contaminants, formulation and excipients, container, closure, as well as degradation products are all implicated. However, a critical examination of the available data shows that clear unequivocal evidence for the impact of these latter factors on clinical immunogenicity is lacking. No report could be found that clearly deconvolutes the clinical impact of the product attributes on patient susceptibility. Aggregation carries the greatest concern as a risk factor for immunogenicity, but the impact of aggregates is likely to depend on their structure as well as on the functionality (e.g., immunostimulatory or immunomodulatory) of the therapeutic. Preclinical studies are not yet capable of assessing the clinically relevant immunogenicity potential of these product-related factors. Simply addressing these risk factors as part of product development will not eliminate immunogenicity. Minimization of immunogenicity has to begin at the molecule design stage by reducing or eliminating antigenic epitopes and building in favorable physical and chemical properties. Copyright © 2010 Wiley-Liss, Inc.

  2. Gastrointestinal toxicity and its relation to dose distributions in the anorectal region of prostate cancer patients treated with radiotherapy

    International Nuclear Information System (INIS)

    Heemsbergen, Wilma D.; Hoogeman, Mischa S.; Hart, Guus A.M.; Lebesque, Joos V.; Koper, Peter C.M.

    2005-01-01

    Purpose: To study the correlations between the dose distributions in the anorectal region and late GI symptoms in patients treated for localized prostate carcinoma. Methods and materials: Data from a randomized study were analyzed. In this trial, patients were treated with either rectangular or conformal fields with a dose of 66 Gy. Data concerning GI symptoms were collected from questionnaires of 197 patients. The distributions of the anorectal region were projected on maps, and the dose parameters were calculated. The incidences of complaints were studied as a function of the dose-area parameters and clinical parameters, using a proportional hazard regression model. Finally, we tested a series of dose parameters originating from different parts of the anorectal region. Results: Analyzing the total region, only a statistically significant dose-area effect relation for bleeding was found (p < 0.01). Defining subareas, we found effect relations for bleeding, soiling, fecal incontinence, and mucus loss. For bleeding and mucus loss, the strongest correlation was found for the dose received by the upper 70-80% of the anorectal region (p < 0.01). For soiling and fecal incontinence, we found the strongest association with the dose to the lower 40-50% (p < 0.05). Conclusion: We found evidence that complaints originate from specific regions of the irradiated lower GI tract. Bleeding and mucus loss are probably related to irradiation of the upper part of the rectum. Soiling and fecal incontinence are more likely related to the dose to the anal canal and the lower part of the rectum

  3. Endogenous factors that relate to the eating habits of adolescents ...

    African Journals Online (AJOL)

    The aim in this research was to determine how endogenous factors such as gender, intelligence, self-concept, and personality relate to the eating habits of adolescents. An empirical investigation was conducted using 340 secondary school learners, 162 boys and 178 girls. From the results it appeared that girls tend to have ...

  4. Effects of Procurement Related Factors on Construction Project ...

    African Journals Online (AJOL)

    Several Literatures in construction management support the view that procurements have impacts on project performance. Aim of this study is to investigate the effects of procurement related factors of procurement selection criteria, tendering methods and variation orders on project performance. Purpose of the study is to ...

  5. Aerobic fitness related to cardiovascular risk factors in young children

    DEFF Research Database (Denmark)

    Dencker, Magnus; Thorsson, Ola; Karlsson, Magnus K

    2012-01-01

    Low aerobic fitness (maximum oxygen uptake (VO(2PEAK))) is predictive for poor health in adults. In a cross-sectional study, we assessed if VO(2PEAK) is related to a composite risk factor score for cardiovascular disease (CVD) in 243 children (136 boys and 107 girls) aged 8 to 11 years. VO(2PEAK...

  6. Expression of human soluble tumor necrosis factor (TNF)-related ...

    African Journals Online (AJOL)

    DR NJ TONUKARI

    2011-06-06

    Jun 6, 2011 ... bio-technique in bacterial (Lin et al., 2007), yeast (Xu et al., 2003) ... biological activity, such as human somatotropin (hST) .... sion way with chloroplast transit peptide (Wang et al., .... chloroplast protein synthesis capacity by massive expression of a ... necrosis factor-related apoptosis-inducing ligand in vivo.

  7. The Relative Importance of Job Factors: A New Measurement Approach.

    Science.gov (United States)

    Nealey, Stanley M.

    This paper reports on a new two-phase measurement technique that permits a direct comparison of the perceived relative importance of economic vs. non-economic factors in a job situation in accounting for personnel retention, the willingness to produce, and job satisfaction. The paired comparison method was used to measure the preferences of 91…

  8. School-Related Factors Affecting High School Seniors' Methamphetamine Use

    Science.gov (United States)

    Stanley, Jarrod M.; Lo, Celia C.

    2009-01-01

    Data from the 2005 Monitoring the Future survey were used to examine relationships between school-related factors and high school seniors' lifetime methamphetamine use. The study applied logistic regression techniques to evaluate effects of social bonding variables and social learning variables on likelihood of lifetime methamphetamine use. The…

  9. Overstory removal: stand factors related to success and failure

    Science.gov (United States)

    Robert J. Laacke; Gary O. Fiddler

    1986-01-01

    Overstory removal can offer economic and esthetic advantages over clearcutting and regeneration, but projecting success is difficult. Twenty-nine units on nine operational overstory removal cuts in northern California were studied to determine what factors are related to satisfactory or unsatisfactory stocking after harvest. Stocking determinations were based on number...

  10. Factors and Problems Related to Female Genital Mutilation as Seen ...

    African Journals Online (AJOL)

    Objective: To determine the aetiological factors and problems related to female genital mutilation as seen in children at St. Gaspar Hospital. Data source: Secondary data were obtained from St. Gaspar Hospital, records, registers and patients files or case notes from children ward were retrieved and reviewed, later a special ...

  11. Patient and social work factors related to successful placement of ...

    African Journals Online (AJOL)

    Patient and social work factors related to successful placement of long-term psychiatric in-patients from a specialist psychiatric hospital in South Africa. ... away; a low frequency of behavioural problems (especially of cannabis abuse, verbal or physical aggression, uncontrolled sexual activity), and agitation or restlessness.

  12. Factors Affecting Performance of Undergraduate Students in Construction Related Disciplines

    Science.gov (United States)

    Olatunji, Samuel Olusola; Aghimien, Douglas Omoregie; Oke, Ayodeji Emmanuel; Olushola, Emmanuel

    2016-01-01

    Academic performance of students in Nigerian institutions has been of much concern to all and sundry hence the need to assess the factors affecting performance of undergraduate students in construction related discipline in Nigeria. A survey design was employed with questionnaires administered on students in the department of Quantity Surveying,…

  13. Evaluating medical and systemic factors related to maternal and ...

    African Journals Online (AJOL)

    Background: This study examined maternal morbidity and mortality and neonatal mortality over a multi-year period from de-identified retrospective medical records at Nyakahanga Designated District Hospital in north-western Tanzania. The study aimed to examine factors related to maternal mortality (MMR) and morbidity in ...

  14. Work related injuries and associated factors among small scale ...

    African Journals Online (AJOL)

    Objective: This study aims to assess the magnitude of work related injury and associated factors among small scale industrial workers in Mizan-Aman town, Bench Maji Zone, Southwest Ethiopia. Method: A cross-sectional study design was conducted from February to May, 2016. Data was collected using a structured face to ...

  15. Factors Related to Teenage Dating Violence Prevention Programming in Schools

    Science.gov (United States)

    Black, Beverly M.; Hawley, Alicia; Hoefer, Richard; Barnett, Tracey M.

    2017-01-01

    The Children's Safety Network has identified teenage dating violence (TDV) as a public health problem and called for effective prevention programs to address the issue. This study used resource dependence theory to examine factors that relate to domestic violence shelters' in-school efforts to prevent TDV. A national survey was sent to domestic…

  16. Relative contributions of individual, institutional and system factors ...

    African Journals Online (AJOL)

    This study investigated the relative contributions of individual, institutional and system factors to utilisation of Research4Life databases by scientists in the National Agricultural Research Institutes (NARIs) in Nigeria. The study adopted the descriptive survey research design of the correlational type. Simple and stratified ...

  17. Community reintegration and related factors in a Nigerian stroke ...

    African Journals Online (AJOL)

    Background: The goal of stroke rehabilitation has shifted from mere survival of a victim to how well a survivor can be effectively reintegrated back into the community. Objectives: The present study determined the level of satisfaction with community reintegration (CR) and related factors among Nigerian community-dwelling ...

  18. Burnout in the working population: relations to psychosocial work factors.

    Science.gov (United States)

    Lindblom, Karin M; Linton, Steven J; Fedeli, Cecilia; Bryngelsson, Ing-Liss

    2006-01-01

    This study investigated levels of burnout in the general population irrespective of occupation and relations between burnout and psychosocial work factors. A cross-sectional survey featuring sleep problems, psychological distress, burnout (Maslach Burnout Inventory-General Survey), and psychosocial factors at work, was mailed to a random sample of 3,000 participants, aged 20-60. Response rate was 61%. A high level (18%), a low level (19%), and an intermediate group (63%) for burnout were constructed. The high level group was associated with those who were > 50 years old, women, those experiencing psychological distress, and those with a poor psychosocial work climate. The analyses on variables significant in previous analyses showed that the high level group was strongly related to high demands, low control, lack of social support, and disagreeing about values at the workplace even when accounting for age, gender, and psychological distress. We conclude that psychosocial work factors are important in association to burnout regardless of occupation.

  19. Age-related percutaneous penetration part 1: skin factors.

    Science.gov (United States)

    Konda, S; Meier-Davis, S R; Cayme, B; Shudo, J; Maibach, H I

    2012-05-01

    Changes in the skin that occur in the elderly may put them at increased risk for altered percutaneous penetration from pharmacotherapy along with potential adverse effects. Skin factors that may have a role in age-related percutaneous penetration include blood flow, pH, skin thickness, hair and pore density, and the content and structure of proteins, glycosaminoglycans (GAGs), water, and lipids. Each factor is examined as a function of increasing age along with its potential impact on percutaneous penetration. Additionally, topical drugs that successfully overcome the barrier function of the skin can still fall victim to cutaneous metabolism, thereby producing metabolites that may have increased or decreased activity. This overview discusses the current data and highlights the importance of further studies to evaluate the impact of skin factors in age-related percutaneous penetration.

  20. Absorbed dose beam quality factors for cylindrical ion chambers: Experimental determination at 6 and 15 MV photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Caporali, C; Guerra, A S; Laitano, R F; Pimpinella, M [ENEA-Casaccia, Inst. Nazionale di Meterologia delle Radiazioni Ionizzanti, Rome (Italy). Dipt. Ambiente

    1996-08-01

    Ion chambers calibrated in terms of absorbed dose to water need an additional factor conventionally designed by k{sub Q} in order to determine the absorbed dose. The quantity k{sub Q} depends on beam quality and chamber characteristics. Rogers and Andreo provided calculations of the k{sub Q} factors for most commercially available ionization chambers for clinical dosimetry. Experimental determinations of the k{sub Q} factors for a number of cylindrical ion chambers have been made and are compared with the calculated values so far published. Measurements were made at 6 MV and 15 MV clinical photon beams at a point in water phantom where the ion chambers and a Fricke dosimeter were alternatively irradiated. The uncertainty on the experimental k{sub Q} factors resulted about {+-} 0.6%. The theoretical and experimental k{sub Q} values are in fairly good agreement. (author). 12 refs, 3 tabs.

  1. Pharmacokinetics and dose requirements of factor VIII over the age range 3-74 years

    DEFF Research Database (Denmark)

    Björkman, Sven; Folkesson, Anna; Jönsson, Siv

    2009-01-01

    in the sparse clinical data. Model-predicted doses (based on age and body weight) to maintain a recommended 0.01 U/mL trough level of FVIII with administration on alternate days started at around 60 U/kg in the small children, decreasing to 10 U/kg or less in middle age. However, "true" dose requirements......, as estimated from individual PK parameter data, showed a much greater variation. CONCLUSION: Appropriate dosing of FVIII for prophylactic treatment cannot be calculated only from body weight and/or age. However, plausible starting doses for most patients would be 1,000 U every other day. FVIII levels should...... can be calculated according to patient characteristics, and (3) to present dosing recommendations for initiating prophylactic treatment. METHODS: A population PK model was developed using data from four PK studies on patients aged 7-74 years. The model was tested on sparse FVIII data from 42...

  2. Factoring the dispersion relation in the presence of Lorentz violation

    International Nuclear Information System (INIS)

    Colladay, Don; McDonald, Patrick; Mullins, David

    2010-01-01

    We produce an explicit formula for the dispersion relation for the Dirac equation in the standard model extension in the presence of Lorentz violation. Our expression is obtained using novel techniques which exploit the algebra of quaternions. The dispersion relation is found to conveniently factor in two special cases that each involve a mutually exclusive set of nonvanishing Lorentz-violating parameters. This suggests that a useful approach to studies of Lorentz-violating models is to split the parameter space into two separate pieces, each of which yields a simple, tractable dispersion relation that can be used for analysis.

  3. Factors that drive insulin-dosing decisions of diabetes care providers: a vignette-based study in the Netherlands

    NARCIS (Netherlands)

    Simon, A. C. R.; Schopman, J. E.; Hoekstra, J. B. L.; Abu-Hanna, A.; Gerdes, V. E. A.; Peek, N.; Holleman, F.

    2015-01-01

    To test how certain patient factors would influence the decision of Dutch care providers regarding insulin dose adjustments. We hypothesize that some of these decisions would diverge from recent evidence and consensus statements. We developed narrative vignettes describing clinical scenarios of

  4. Radiolabeled cetuximab: dose optimization for epidermal growth factor receptor imaging in a head-and-neck squamous cell carcinoma model

    NARCIS (Netherlands)

    Hoeben, B.A.W.; Molkenboer-Kuenen, J.D.M.; Oyen, W.J.G.; Peeters, W.J.M.; Kaanders, J.H.A.M.; Bussink, J.; Boerman, O.C.

    2011-01-01

    Noninvasive imaging of the epidermal growth factor receptor (EGFR) in head-and-neck squamous cell carcinoma could be of value to select patients for EGFR-targeted therapy. We assessed dose optimization of (111) Indium-DTPA-cetuximab ((111) In-cetuximab) for EGFR imaging in a head-and-neck squamous

  5. Efficacy, safety and proper dose analysis of PEGylated granulocyte colony-stimulating factor as support for dose-dense adjuvant chemotherapy in node positive Chinese breast cancer patients.

    Science.gov (United States)

    Zhang, Fan; LingHu, RuiXia; Zhan, XingYang; Li, Ruisheng; Feng, Fan; Gao, Xudong; Zhao, Lei; Yang, Junlan

    2017-10-03

    For high-risk breast cancer patients with positive axillary lymph nodes, dose-dense every-two-week epirubicin/cyclophosphamide-paclitaxel (ddEC-P) regimen is the optimal postoperative adjuvant therapy. However, this regimen is limited by the grade 3/4 neutropenia and febrile neutropenia (FN). There is an urgent need to explore the efficacy, safety and proper dosage of PEGylated granulocyte colony-stimulating factor (PEG-G-CSF) as support for ddEC-P in Chinese breast cancer patients with positive axillary lymph nodes. Prospectively, 40 women with stage IIIA to IIIC breast cancer received ddEC-P ± trastuzumab as adjuvant treatment. PEG-G-CSF was injected subcutaneously in a dose of 6 mg or 3 mg on the 2 th day of each treatment cycle. With administration of PEG-G-CSF, all of the 40 patients completed 8 cycles of ddEC-P ± trastuzumab regimen without dose reductions or treatment delays. Moreover, no FN cases were observed. Further analysis showed that the proper dosage of PEG-G-CSF was 6 mg for ddEC treatment, and 3 mg for ddP treatment. PEG-G-CSF exhibits advantages compared with G-CSF in convenient of administration and tolerance for high risk Chinese breast cancer patients. More importantly, the proper dose of PEG-G-CSF for high risk Chinese breast cancer patients during ddEC-P chemotherapy may be 6 mg for ddEC treatment and 3 mg for ddP treatment.

  6. The sensitivity of laboratory tests assessing driving related skills to dose-related impairment of alcohol: A literature review.

    Science.gov (United States)

    Jongen, S; Vuurman, E F P M; Ramaekers, J G; Vermeeren, A

    2016-04-01

    Laboratory tests assessing driving related skills can be useful as initial screening tools to assess potential drug induced impairment as part of a standardized behavioural assessment. Unfortunately, consensus about which laboratory tests should be included to reliably assess drug induced impairment has not yet been reached. The aim of the present review was to evaluate the sensitivity of laboratory tests to the dose dependent effects of alcohol, as a benchmark, on performance parameters. In total, 179 experimental studies were included. Results show that a cued go/no-go task and a divided attention test with primary tracking and secondary visual search were consistently sensitive to the impairing effects at medium and high blood alcohol concentrations. Driving performance assessed in a simulator was less sensitive to the effects of alcohol as compared to naturalistic, on-the-road driving. In conclusion, replicating results of several potentially useful tests and their predictive validity of actual driving impairment should deserve further research. In addition, driving simulators should be validated and compared head to head to naturalistic driving in order to increase construct validity. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  8. Factors influencing the relation between alcohol and cardiovascular disease

    DEFF Research Database (Denmark)

    Grønbaek, Morten

    2006-01-01

    PURPOSE OF REVIEW: Light-to-moderate alcohol intake is known to have cardioprotective properties in some subsets of the population. This review focuses on factors that modify the relation between alcohol and cardiovascular disease. RECENT FINDINGS: Several large American studies have shown...... to a binge - intake of alcohol have benefits with regard to cardiovascular disease. Prospective studies from the UK, Sweden and Denmark have further suggested that wine drinkers have a lower mortality than beer and spirits drinkers. SUMMARY: The J-shaped relation between alcohol intake and cardiovascular...... that the J-shaped relation is influenced by age and coronary heart disease risk-factor status since only middle-aged and elderly and those already at risk of developing coronary heart disease seem protected by drinking alcohol. It has also been suggested that only those who have a steady - in contrast...

  9. Determination of absorbed dose calibration factors for therapy level electron beam ionization chambers.

    Science.gov (United States)

    McEwen, M R; Williams, A J; DuSautoy, A R

    2001-03-01

    Over several years the National Physical Laboratory (NPL) has been developing an absorbed dose calibration service for electron beam radiotherapy. To test this service, a number of trial calibrations of therapy level electron beam ionization chambers have been carried out during the last 3 years. These trials involved 17 UK radiotherapy centres supplying a total of 46 chambers of the NACP, Markus, Roos and Farmer types. Calibration factors were derived from the primary standard calorimeter at seven energies in the range 4 to 19 MeV with an estimated uncertainty of +/-1.5% at the 95% confidence level. Investigations were also carried out into chamber perturbation, polarity effects, ion recombination and repeatability of the calibration process. The instruments were returned to the radiotherapy centres for measurements to be carried out comparing the NPL direct calibration with the 1996 IPEMB air kerma based Code of Practice. It was found that, in general, all chambers of a particular type showed the same energy response. However, it was found that polarity and recombination corrections were quite variable for Markus chambers-differences in the polarity correction of up to 1% were seen. Perturbation corrections were obtained and were found to agree well with the standard data used in the IPEMB Code. The results of the comparison between the NPL calibration and IPEMB Code show agreement between the two methods at the +/-1% level for the NACP and Farmer chambers, but there is a significant difference for the Markus chambers of around 2%. This difference between chamber types is most likely to be due to the design of the Markus chamber.

  10. Medication Incidents Related to Automated Dose Dispensing in Community Pharmacies and Hospitals - A Reporting System Study

    Science.gov (United States)

    Cheung, Ka-Chun; van den Bemt, Patricia M. L. A.; Bouvy, Marcel L.; Wensing, Michel; De Smet, Peter A. G. M.

    2014-01-01

    Introduction Automated dose dispensing (ADD) is being introduced in several countries and the use of this technology is expected to increase as a growing number of elderly people need to manage their medication at home. ADD aims to improve medication safety and treatment adherence, but it may introduce new safety issues. This descriptive study provides insight into the nature and consequences of medication incidents related to ADD, as reported by healthcare professionals in community pharmacies and hospitals. Methods The medication incidents that were submitted to the Dutch Central Medication incidents Registration (CMR) reporting system were selected and characterized independently by two researchers. Main Outcome Measures Person discovering the incident, phase of the medication process in which the incident occurred, immediate cause of the incident, nature of incident from the healthcare provider's perspective, nature of incident from the patient's perspective, and consequent harm to the patient caused by the incident. Results From January 2012 to February 2013 the CMR received 15,113 incidents: 3,685 (24.4%) incidents from community pharmacies and 11,428 (75.6%) incidents from hospitals. Eventually 1 of 50 reported incidents (268/15,113 = 1.8%) were related to ADD; in community pharmacies more incidents (227/3,685 = 6.2%) were related to ADD than in hospitals (41/11,428 = 0.4%). The immediate cause of an incident was often a change in the patient's medicine regimen or relocation. Most reported incidents occurred in two phases: entering the prescription into the pharmacy information system and filling the ADD bag. Conclusion A proportion of incidents was related to ADD and is reported regularly, especially by community pharmacies. In two phases, entering the prescription into the pharmacy information system and filling the ADD bag, most incidents occurred. A change in the patient's medicine regimen or relocation was the immediate causes of an incident

  11. Predicting treatment related imaging changes (TRICs) after radiosurgery for brain metastases using treatment dose and conformality metrics.

    Science.gov (United States)

    Taylor, B Frazier; Knisely, Jonathan P; Qian, Jack M; Yu, James B; Chiang, Veronica L

    2016-01-01

    Treatment-related imaging changes (TRICs) after stereotactic radiosurgery (SRS) involves the benign transient enlargement of radiographic lesions after treatment. Identifying the radiation dose volumes and conformality metrics associated with TRICs for different post-treatment periods would be helpful and improve clinical decision making. 367 metastases in 113 patients were treated using Gamma Knife SRS between 1/1/2007-12/31/2009. Each metastasis was measured at each imaging follow-up to detect TRICs (defined as ≥ 20% increase in volume). Fluctuations in small volume lesions (less than 108 mm 3 ) were ignored given widely variable conformity indices (CI) for small volumes. The Karolinska Adverse Radiation Effect (KARE) factor, Paddick's CI, Shaw's CI, tumor volume (TV), 10 Gy (V10) and 12 Gy (V12) volumes, and prescription isodose volume (PIV) were calculated. From 0-6 months, all measures correlated with the incidence of TRICs (p<.001), except KARE, which was inversely correlated. During the 6-12 month period all measures except KARE were still correlated. Beyond 12 months, no correlation was found between any of the measures and the development of TRICs. All metrics except KARE were associated with TRICs from 0-12 months only. Additional patient and treatment factors may become dominant at greater times after SRS.

  12. Dose-Related Differences in Effectiveness of Human Papillomavirus Vaccination Against Genital Warts

    DEFF Research Database (Denmark)

    Blomberg, Maria; Dehlendorff, Christian; Sand, Carsten

    2015-01-01

    BACKGROUND: Reducing the number of doses in the human papillomavirus (HPV) vaccination regimen from 3 to 2 could increase coverage rates. In this cohort study, we assessed the risk of genital warts (GWs) according to timing and number of doses of quadrivalent HPV vaccine. METHODS: From population......-based registries, we identified all girls in Denmark born during 1985-1999, for whom information on HPV vaccinations was retrieved. The cohort was followed for GW occurrence during 2006-2012. Incidence rate ratios (IRRs) were calculated by Poisson regression to determine differences in GW rates by number...... of vaccine doses. RESULTS: Of the 550,690 girls in the cohort, 361 734 had been vaccinated. Of these, 25.9% had been vaccinated twice and 58.8% 3 times. The risk of GWs decreased significantly with each additional dose of vaccine. For girls who received 2 doses, extension of the interval between doses...

  13. Factors related to falls among community dwelling elderly.

    Science.gov (United States)

    Kuhirunyaratn, Piyathida; Prasomrak, Prasert; Jindawong, Bangonsri

    2013-09-01

    Falls among the elderly can lead to disability, hospitalization and premature death. This study aimed to determine the factors related to falls among community dwelling elderly. This case-control study was conducted at the Samlium Primary Care Unit (SPCU), Khon Kaen, Thailand. Cases were elderly individuals who had fallen within the previous six months and controls were elderly who had not fallen during that same time period. Subjects were taken from elderly persons registered at the SPCU. The sample size was calculated to be 111 cases and 222 controls. Face to face interviews were conducted with subjects between May and June, 2011. The response rate was 100%. On bivariate analysis, the statistically significant factors related to falls were: regular medication use, co-morbidities, mobility, depression, cluttered rooms, slippery floors, unsupported toilets (without a hand rail), sufficient exercise, rapid posture change and wearing slippers. When controlling for others significant factors, multiple logistic regression revealed significant factors were: regular medication use (AOR: 2.22; 95%CI: 1.19 - 4.12), depression (AOR: 1.76, 95% CI: 1.03 - 2.99), sufficient exercise (AOR: 0.34; 95% CI: 0.19 - 0.58) and wearing slippery shoes (AOR: 2.31; 95% CI: 1.24 - 4.29). Interventions need to be considered to modify these significant factors associated with falls and education should be provided to these at risk.

  14. Health related quality of life and influencing factors among welders.

    Directory of Open Access Journals (Sweden)

    Jingxiang Qin

    Full Text Available BACKGROUND: Occupational exposure to welding fumes is a serious occupational health problem all over the world. Welders are exposed to many occupational hazards; these hazards might cause some occupational diseases. The aim of the study was to assess the health related quality of life (HRQL of electric welders in Shanghai China and explore influencing factors to HRQL of welders. METHODS: 301 male welders (without pneumoconiosis and 305 non-dust male workers in Shanghai were enrolled in this study. Short Form-36 (SF-36 health survey questionnaires were applied in this cross-sectional study. Socio-demographic, working and health factors were also collected. Multiple stepwise regress analysis was used to identify significant factors related to the eight dimension scores. RESULTS: Six dimensions including role-physical (RP, bodily pain (BP, general health (GH, validity (VT, social function (SF, and mental health (MH were significantly worse in welders compared to non-dust workers. Multiple stepwise regress analysis results show that native place, monthly income, quantity of children, drinking, sleep time, welding type, use of personal protective equipment (PPE, great events in life, and some symptoms including dizziness, discomfort of cervical vertebra, low back pain, cough and insomnia may be influencing factors for HRQL of welders. Among these factors, only sleep time and the use of PPE were salutary. CONCLUSIONS: Some dimensions of HRQL of these welders have been affected. Enterprises which employ welders should take measures to protect the health of these people and improve their HRQL.

  15. [Risk factors related to surgical site infection in elective surgery].

    Science.gov (United States)

    Angeles-Garay, Ulises; Morales-Márquez, Lucy Isabel; Sandoval-Balanzarios, Miguel Antonio; Velázquez-García, José Arturo; Maldonado-Torres, Lulia; Méndez-Cano, Andrea Fernanda

    2014-01-01

    The risk factors for surgical site infections in surgery should be measured and monitored from admission to 30 days after the surgical procedure, because 30% of Surgical Site Infection is detected when the patient was discharged. Calculate the Relative Risk of associated factors to surgical site infections in adult with elective surgery. Patients were classified according to the surgery contamination degree; patient with surgery clean was defined as no exposed and patient with clean-contaminated or contaminated surgery was defined exposed. Risk factors for infection were classified as: inherent to the patient, pre-operative, intra-operative and post-operative. Statistical analysis; we realized Student t or Mann-Whitney U, chi square for Relative Risk (RR) and multivariate analysis by Cox proportional hazards. Were monitored up to 30 days after surgery 403 patients (59.8% women), 35 (8.7%) developed surgical site infections. The factors associated in multivariate analysis were: smoking, RR of 3.21, underweight 3.4 hand washing unsuitable techniques 4.61, transfusion during the procedure 3.22, contaminated surgery 60, and intensive care stay 8 to 14 days 11.64, permanence of 1 to 3 days 2.4 and use of catheter 1 to 3 days 2.27. To avoid all risk factors is almost impossible; therefore close monitoring of elective surgery patients can prevent infectious complications.

  16. Convulsive syncope related to a small dose of quetiapine in an adolescent with bipolar disorder

    Directory of Open Access Journals (Sweden)

    Lai J

    2017-07-01

    Full Text Available Jianbo Lai,1,2 Qiaoqiao Lu,3 Tingting Huang,3 Shaohua Hu,1,2 Yi Xu1,2 1Department of Psychiatry, First Affiliated Hospital, Zhejiang University School of Medicine, 2Key Laboratory of Mental Disorder Management in Zhejiang Province, 3Department of Internal Medicine, Zhejiang University School of Medicine, Hangzhou, China Abstract: Quetiapine, an atypical antipsychotic, has been extensively used in patients with bipolar disorder. Overdose of quetiapine can result in severe complications, such as coma, seizure, respiratory depression, arrhythmia, and even death. However, the paucity of toxicological evaluation in adolescence causes more potential risks in this population. Herein, we present a case of hypotension and convulsive syncope after exposure to a small dose of quetiapine in a 16-year-old who was diagnosed with bipolar disorder. After cessation of quetiapine, no additional convulsive movements were reported. This case indicates that even in young patients without predisposing factors, close monitoring of adverse effects should be warranted for safety concerns, especially at the initiation of quetiapine treatment. Keywords: quetiapine, bipolar disorder, hypotension, convulsive syncope

  17. Factors that influence the relative use of multiple memory systems.

    Science.gov (United States)

    Packard, Mark G; Goodman, Jarid

    2013-11-01

    Neurobehavioral evidence supports the existence of at least two anatomically distinct "memory systems" in the mammalian brain that mediate dissociable types of learning and memory; a "cognitive" memory system dependent upon the hippocampus and a "stimulus-response/habit" memory system dependent upon the dorsolateral striatum. Several findings indicate that despite their anatomical and functional distinctiveness, hippocampal- and dorsolateral striatal-dependent memory systems may potentially interact and that, depending on the learning situation, this interaction may be cooperative or competitive. One approach to examining the neural mechanisms underlying these interactions is to consider how various factors influence the relative use of multiple memory systems. The present review examines several such factors, including information compatibility, temporal sequence of training, the visual sensory environment, reinforcement parameters, emotional arousal, and memory modulatory systems. Altering these parameters can lead to selective enhancements of either hippocampal-dependent or dorsolateral striatal-dependent memory, and bias animals toward the use of either cognitive or habit memory in dual-solution tasks that may be solved adequately with either memory system. In many learning situations, the influence of such experimental factors on the relative use of memory systems likely reflects a competitive interaction between the systems. Research examining how various factors influence the relative use of multiple memory systems may be a useful method for investigating how these systems interact with one another. Copyright © 2013 Wiley Periodicals, Inc.

  18. Mechanical factors relate to pain in knee osteoarthritis.

    Science.gov (United States)

    Maly, Monica R; Costigan, Patrick A; Olney, Sandra J

    2008-07-01

    Pain experienced by people with knee osteoarthritis is related to psychosocial factors and damage to articular tissues and/or the pain pathway itself. Mechanical factors have been speculated to trigger this pain experience; yet mechanics have not been identified as a source of pain in this population. The purpose of this study was to identify whether mechanics could explain variance in pain intensity in people with knee osteoarthritis. Data from 53 participants with physician-diagnosed knee osteoarthritis (mean age=68.5 years; standard deviation=8.6 years) were analyzed. Pain intensity was reported on the Western Ontario and McMaster Universities Osteoarthritis Index. Mechanical measures included weight-bearing varus-valgus alignment, body mass index and isokinetic quadriceps torque. Gait analysis captured the range of adduction-abduction angle, range of flexion-extension angle and external knee adduction moment during level walking. Pain intensity was significantly related to the dynamic range of flexion-extension during gait and body mass index. A total of 29% of the variance in pain intensity was explained by mechanical variables. The range of flexion-extension explained 18% of variance in pain intensity. Body mass index added 11% to the model. The knee adduction moment was unrelated to pain intensity. The findings support that mechanical factors are related to knee osteoarthritis pain. Because limitations in flexion-extension range of motion and body size are modifiable factors, future research could examine whether interventions targeting these mechanics would facilitate pain management.

  19. Radiation retinopathy after external-beam irradiation: Analysis of time-dose factors

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Mendenhall, W.M.

    1994-01-01

    To investigate the risk of radiation-induced retinopathy according to total radiation dose and fraction size, based on both retorspective and prospectively collected data. Between October 1964 and May 1989, 68 retinae in 64 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 26 years; mean, 9 years; median, 8 years). Twenty-seven eyes in 26 patients developed radiation retinopathy resulting in visual acuity of 20/200 or worse. The mean and median times to the onset of symptoms attributable to retinal ischemia were 2.8 and 2.5 years, respectively. Fourteen of the injured eyes developed rubeosis iridis and/or neovascular glaucoma. Radiation retinopathy was not observed at doses below 45 Gy, but increased steadily in incidence at doses ≥45Gy. In the range of doses between 45 and 55 Gy, there was an increased risk of injury among patients who received doses per fraction of ≥1.9Gy (p - .09). There was also a trend toward increased risk of injury among patients who received chemotherapy (two of two vs. four of ten in the 45-51 Gy range; p - .23). The lowest dose associated with retinopathy was 45 Gy delivered to a diabetic patient by twice-a-day fractionation. The data did not suggest an increased risk of radiation retinopathy with increasing age. The current study suggests the importance of total dose as well as dose per fraction, and adds support to a small body of literature suggesting that patients with diabetes mellitus or who receive chemotherapy are at increased risk of injury. A sigmoid dose-response curve is constructed from our current data and data from the literature. 36 refs., 5 figs., 4 tabs

  20. Doses and population irradiation factors for Canadian radiation technologists (1978 to 1988)

    International Nuclear Information System (INIS)

    Huda, W.; Bews, J.; Gordon, K.; Sutherland, J.B.; Sont, W.N.; Ashmore, J.P.

    1991-01-01

    Individual and collective radiation doses received by Canadian radiation technologists (RTs) working in diagnostic radiology, nuclear medicine and radiotherapy are summarized for the period 1978 to 1988. The data were obtained directly from the National Dose Registry, Department of National Health and Welfare. Over the 11-year study period the mean annual dose equivalent fluctuated around 0.2, 1.8 and 1.1 mSv for RTs working in diagnostic radiology, nuclear medicine and radiotherapy respectively. Over the same period the occupational collective dose equivalent decreased in diagnostic radiology by 44% and radiotherapy by 35%, and increased in nuclear medicine by 45%. Approximately 10 000 RTs are monitored each year, with an estimated total occupational collective dose equivalent of about 3.6 person-sievert. Analysis of dose distribution data showed that only 1.3% of all monitored RTs received an annual whole-body dose equivalent greater than the current legal limit for members of the public (5 mSv). Approximately half of the RTs working in nuclear medicine and radiotherapy received an annual dose equivalent in excess of 0.5 mSv; only 7.3% of their diagnostic radiology counterparts exceeded this level. Demographic data showed a high preponderance of young women in all three RT classifications, and an analysis of the radiation risks to this occupational group revealed increases of up to 12% above the risk associated with a 'standard' adult working population exposed to the same collective dose equivalent. (20 refs., 4 tabs., fig.)

  1. Cancer Control Related to Stimulation of Immunity by Low-Dose Radiation

    OpenAIRE

    Liu, Shu-Zheng

    2006-01-01

    Previous studies showed that low dose radiation (LDR) could stimulate the immune system in both animal and human populations. This paper reviews the present status of relevant research as support to the use of LDR in clinical practice for cancer prevention and treatment. It has been demonstrated that radiation-induced changes in immune activity follows an inverse J-shaped curve, i.e., low dose stimulation and high dose suppression. The stimulation of immunity by LDR concerns most anticancer p...

  2. Time-related factors in the study of risks in animals and humans

    International Nuclear Information System (INIS)

    Gilbert, E.S.; Park, J.F.; Buschbom, R.L.

    1989-01-01

    Data from epidemiological studies of humans exposed to potentially harmful substances are usually analyzed using methods that account for the dependence of risks on time-related factors such as age and follow-up period. Recently developed statistical procedures allow modeling of the age-specific risks as a function of dose as well as factors such as age at exposure, time since exposure, exposure duration, and dose rate. These procedures potentially allow more rigorous inferences and clearer understanding of the patterns of risk observed in epidemiological studies than has been available in the past. Statistical procedures that consider time-related factors can also be applied to laboratory animal data, providing information that is useful for the problems involved in extrapolating from animal studies to humans. By applying such procedures to data on exposure to the same substance in different species (including humans) or to different substances in the same species, better understanding of the relationship of risks across species and across substances can be achieved. In addition, such statistical procedures allow appropriate treatment of exposure that is accumulated over time and lead to improved understanding of patterns of risk over time. The approach is illustrated using data from a lifespan study of beagle dogs exposed to inhaled Pu

  3. Time-related factors in the study of risks in animals and man

    International Nuclear Information System (INIS)

    Gilbert, E.S.; Park, J.F.; Buschbom, R.L.

    1988-01-01

    Data from epidemiological studies of humans exposed to potentially harmful substances are usually analyzed using methods that account for the dependence of risks on time-related factors such as age and follow-up period. Recently developed statistical procedures allow modeling of the age-specific risks as a function of dose as well as factors such as age at exposure, time from exposure, exposure duration, and dose rate. These procedures potentially allow more rigorous inferences and clearer understanding of the patterns of risks observed in epidemiological studies than has been available in the past. Statistical procedures that consider time-related factors can also be applied to laboratory animal data, and provide information that is useful for the problem of extrapolating from animal studies to humans. By applying such procedures to data on exposure to the same substance in different species (including humans) or to different substances in the same species, a better understanding of the relationship of risks across species and across substances can be achieved. In addition, such statistical procedures allow appropriate treatment of exposure that is accumulated over time and lead to improved understanding of patterns of risk over time. The approach is illustrated using data from a lifespan study of beagle dogs exposed to inhaled plutonium. 12 refs., 1 fig., 3 tabs

  4. Risk factors of age-related macular degeneration in Argentina

    Directory of Open Access Journals (Sweden)

    María Eugenia Nano

    2013-04-01

    Full Text Available PURPOSES: To assess the risk factors of age-related macular degeneration in Argentina using a case-control study. METHODS: Surveys were used for subjects' antioxidant intake, age/gender, race, body mass index, hypertension, diabetes (and type of treatment, smoking, sunlight exposure, red meat consumption, fish consumption, presence of age-related macular degeneration and family history of age-related macular degeneration. Main effects models for logistic regression and ordinal logistic regression were used to analyze the results. RESULTS: There were 175 cases and 175 controls with a mean age of 75.4 years and 75.5 years, respectively, of whom 236 (67.4% were female. Of the cases with age-related macular degeneration, 159 (45.4% had age-related macular degeneration in their left eyes, 154 (44.0% in their right eyes, and 138 (39.4% in both eyes. Of the cases with age-related macular degeneration in their left eyes, 47.8% had the dry type, 40.3% had the wet type, and the type was unknown for 11.9%. The comparable figures for right eyes were: 51.9%, 34.4%, and 13.7%, respectively. The main effects model was dominated by higher sunlight exposure (OR [odds ratio]: 3.3 and a family history of age-related macular degeneration (OR: 4.3. Other factors included hypertension (OR: 2.1, smoking (OR: 2.2, and being of the Mestizo race, which lowered the risk of age-related macular degeneration (OR: 0.40. Red meat/fish consumption, body mass index, and iris color did not have an effect. Higher age was associated with progression to more severe age-related macular degeneration. CONCLUSION: Sunlight exposure, family history of age-related macular degeneration, and an older age were the significant risk factors. There may be other variables, as the risk was not explained very well by the existing factors. A larger sample may produce different and better results.

  5. Factors related to the liquidations of ETFs during 2008

    Directory of Open Access Journals (Sweden)

    Herminio Romero-Pérez

    2013-10-01

    Full Text Available The purpose of this study is to identify factors related to the closing of 50 ETFs in 2008. The study compared the sample of liquidated ETFs to a matched sample of active ETFs. The factors used as explanatory variables were: market capitalization, liquidity, ETF return, Index return, tracking error, fund age, and premium. Lower liquidity values, higher tracking errors, and higher ETF returns were associated with higher probabilities of liquidation. The researcher found evidence that ETFs’ market makers were profiting from the creation of new ETFs’ shares just before liquidating the ETFs’ shares at a premium.

  6. The impact of non-genetic and genetic factors on a stable warfarin dose in Thai patients.

    Science.gov (United States)

    Wattanachai, Nitsupa; Kaewmoongkun, Sutthida; Pussadhamma, Burabha; Makarawate, Pattarapong; Wongvipaporn, Chaiyasith; Kiatchoosakun, Songsak; Vannaprasaht, Suda; Tassaneeyakul, Wichittra

    2017-08-01

    The aim of this study was to investigate the contributions of non-genetic and genetic factors on the variability of stable warfarin doses in Thai patients. A total of 250 Thai patients with stable warfarin doses were enrolled in the study. Demographics and clinical data, e.g., age, body mass index, indications for warfarin and concomitant medications, were documented. Four single nucleotide polymorphisms in the VKORC1 - 1639G > A, CYP2C9*3, CYP4F2 rs2108622, and UGT1A1 rs887829 genes were detected from gDNA using TaqMan allelic discrimination assays. The patients with variant genotypes of VKORC1 - 1639G > A required significantly lower warfarin stable weekly doses (SWDs) than those with wild-type genotype (p warfarin SWDs than those with homozygous wild-type (p = 0.006). In contrast, there were no significant differences in the SWDs between the patients who carried variant alleles of CYP4F2 rs2108622 and UGT1A1 rs887829 as compared to wild-type allele carriers. Multivariate analysis, however, showed that CYP4F2 rs2108622 TT genotype accounted for a modest part of warfarin dose variability (1.2%). In contrast, VKORC1 - 1639G > A, CYP2C9*3, CYP4F2 rs2108622 genotypes and non-genetic factors accounted for 51.3% of dose variability. VKORC1 - 1639G > A, CYP2C9*3, and CYP4F2 rs2108622 polymorphisms together with age, body mass index, antiplatelet drug use, amiodarone use, and current smoker status explained 51.3% of individual variability in stable warfarin doses. In contrast, the UGT1A1 rs887829 polymorphism did not contribute to dose variability.

  7. The weighting factor for the female breasts: implications for the effective dose equivalent

    International Nuclear Information System (INIS)

    Beentjes, L.B.; Duijsings, J.H.

    1988-01-01

    The results of several surveys indicate that the incidence of radiation-induced breast cancer for the worker would be 200 x 10 -4 Gy -1 in the absolute risk model. The mortality to incidence ratio for breast cancer for the Netherlands is 0.4. Therefore, the absolute risk model would yield a factor of 0.8 x 10 -2 Gy -1 for fatal breast cancer although a value of 0.2 x 10 -2 Gy -1 has also been reported. The relative risk model of BEIR would suggest a risk factor for the female breast of over 1.2 x 10 -2 Gy -1 . The natural incidence of female breast cancer in The Netherlands is, with that in the U.K., the U.S.A. and Switzerland among the highest in the world. In this connection the Dutch National Health Council considers a risk factor of 1.2 x 10 -2 Sv -1 with a range of 0.8 x 10 -2 Sv -1 to 1.6 x 10 -2 Sv -1 for irradiation-induced fatal breast cancer a more representative value than the 0.5 x 10 -2 Sv -1 given in ICRP publications 26

  8. Mobilization and collection of CD34+ cells for autologous transplantation of peripheral blood hematopoietic progenitor cells in children: analysis of two different granulocyte-colony stimulating factor doses

    Directory of Open Access Journals (Sweden)

    Kátia Aparecida de Brito Eid

    2015-06-01

    Full Text Available Introduction: The use of peripheral hematopoietic progenitor cells (HPCs is the cell choice in autologous transplantation. The classic dose of granulocyte-colony stimulating factor (G- CSF for mobilization is a single daily dose of 10 µg/kg of patient body weight. There is a theory that higher doses of granulocyte-colony stimulating factor applied twice daily could increase the number of CD34+ cells collected in fewer leukapheresis procedures. Objective: The aim of this study was to compare a fractionated dose of 15 µg G-CSF/kg of body weight and the conventional dose of granulocyte-colony stimulating factor in respect to the number of leukapheresis procedures required to achieve a minimum collection of 3 × 106 CD34+ cells/kg body weight. Methods: Patients were divided into two groups: Group 10 - patients who received a single daily dose of 10 µg G-CSF/kg body weight and Group 15 - patients who received a fractioned dose of 15 µg G-CSF/kg body weight daily. The leukapheresis procedure was carried out in an automated cell separator. The autologous transplantation was carried out when a minimum number of 3 × 106 CD34+ cells/kg body weight was achieved. Results: Group 10 comprised 39 patients and Group 15 comprised 26 patients. A total of 146 apheresis procedures were performed: 110 (75.3% for Group 10 and 36 (24.7% for Group 15. For Group 10, a median of three (range: 1-7 leukapheresis procedures and a mean of 8.89 × 106 CD34+ cells/kg body weight (±9.59 were collected whereas for Group 15 the corresponding values were one (range: 1-3 and 5.29 × 106 cells/kg body weight (±4.95. A statistically significant difference was found in relation to the number of apheresis procedures (p-value <0.0001. Conclusions: To collect a minimum target of 3 × 106 CD34+ cells/kg body weight, the administration of a fractionated dose of 15 µg G-CSF/kg body weight significantly decreased the number of leukapheresis procedures performed.

  9. Factors related to job satisfaction among South Korean dentists.

    Science.gov (United States)

    Jeong, Seong-Hwa; Chung, Jae-Kyun; Choi, Youn-Hee; Sohn, Woosung; Song, Keun-Bae

    2006-12-01

    The purposes of this study were to investigate the level and distribution of job satisfaction and to explore work environment factors associated with job satisfaction of South Korean dentists. A stratified systematic random sample of 1029 dentists was selected from the 10 357 registered dentists in the Korean Dental Association. They were surveyed via a self-administered mail questionnaire. Job satisfaction was measured by a modified version of the Dentist Satisfaction Survey. The response rate was 62.2%. The mean score of overall job satisfaction among South Korean dentists was 3.2 out of 5. In terms of work environment factors, the most satisfying aspect was patient relations (3.7) and the least satisfying aspect was personal time (2.8). Multiple regression analysis identified a model including patient relations, perception of income, personal time, staff, and specialty training that accounted for 35% of variation in overall job satisfaction. The majority of the variance was explained by patient relations. This study suggests that patient relations, perception of income, personal time, staff, and specialty training are important work environment factors for job satisfaction among South Korean dentists. The findings of this study will be helpful to policy makers to design plans to increase the level of job satisfaction among South Korean dentists.

  10. Salmeterol/fluticasone stable-dose treatment compared with formoterol/budesonide adjustable maintenance dosing: impact on health-related quality of life

    Directory of Open Access Journals (Sweden)

    Williams Angela E

    2007-07-01

    Full Text Available Abstract Background Improving patients' health-related quality of life (HRQoL is recognized as a fundamental part of asthma management. The aims of this study were to evaluate the long-term efficacy (including symptom-free days and exacerbations and impact on HRQoL of a stable-dose regimen of salmeterol/fluticasone propionate (SAL/FP and an adjustable maintenance dosing (AMD regimen of formoterol/budesonide (FOR/BUD where treatment is adjusted based on symptoms [SAM40056]. Methods A total of 688 outpatients with asthma receiving regular low-dose inhaled corticosteroids (ICS plus a long-acting β2-agonist, or medium dose ICS alone participated in this randomized, double-blind, double-dummy, parallel-group, 1-year trial, which was conducted in 91 centers in 15 countries. Patients were randomized to receive 1 inhalation of SAL/FP 50/250 μg BID or 2 inhalations of FOR/BUD 6/200 μg BID during Weeks 1–4. For Weeks 5–52, patients meeting strict continuation criteria for stable asthma at Week 4 received AMD with FOR/BUD or stable-dose SAL/FP. Results The percentage of symptom-free days was significantly greater (58.8% vs 52.1%; p = 0.034 and the annual exacerbation rate was significantly lower (47%; p = 0.008 with stable-dose SAL/FP compared with FOR/BUD AMD. A total of 568 patients completed the Asthma Quality of Life Questionnaire (AQLQ at least once during the study. The mean change from baseline in AQLQ overall score was numerically greater with SAL/FP than FOR/BUD at week 28 and week 52, but did not reach statistical significance (p = 0.121 at Week 52. However, in a post hoc logistic regression analyses for any AQLQ improvement, significant benefits with SAL/FP were seen at both time points (p = 0.038 and p = 0.009, respectively. The minimally important difference of ≥ 0.5-point improvement in AQLQ overall score was achieved by a significantly greater number of patients receiving SAL/FP at Week 28 (68% vs 60%; p = 0.049; a trend for this

  11. Mortality-related Factors in Patients with Malignant Obstructive Jaundice.

    Science.gov (United States)

    Kurniawan, Juferdy; Hasan, Irsan; Gani, Rino Alvani; Simadibrata, Marcellus

    2016-10-01

    to obtain survival rate and mortality-related factors of malignant obstructive jaundice patients. all medical records of obstructive jaundice inpatient at Cipto Mangunkusumo Hospital, Jakarta from January 2010 to December 2013 were reviewed retrospectively. The following factors were analyzed in terms of mortality: age, gender, sepsis, hypoalbumin, serum bilirubin level, serum CA 19-9 level, billiary drainage, non-ampulla Vateri carcinoma, and comorbid factors. total 181 out of 402 patients were enrolled in this study with male proportion was 58.6%, and patients aged 50 years or above was 57.5%. Multivariate analysis showed that only sepsis, unsuccessful or no prior biliary drainage and Charlson comorbid score ≥4 were independent predictors of mortality. Patients with significant prognostic factors had median survival 14 days compared with overall median survival 26 days. Score ≥2 identified as the highest prognostic score threshold with sensitivity 68%, specificity 75%, and AUC on ROC curve 0.769. sepsis, unsuccessful or no prior bilirary drainage, and Charlson comorbid score ≥4 are factors significantly associated with shortened survival in malignant obstructive jaundice patients. Prognostic score  ≥2 was determined to classify patients into high risk mortality group. Mortality of patients with those significant prognostic factors can be predicted in 76.9%.

  12. Study on the mortality in Ecuador related to dietary factors.

    Science.gov (United States)

    Neira-Mosquera, Juan Alejandro; Pérez-Rodríguez, Fernando; Sánchez-Llaguno, Sungey; Moreno Rojas, Rafael

    2013-01-01

    Diet is an important factor related to the development of numerous diseases. In developing countries like Ecuador, this aspect is not considered as priority however, the study of the incidence of certain diet-related diseases could help to assess consumption habits of a country from a Public Health perspective and support national nutrition policies and programs. The objective the present study is to investigate the mortality rate of certain diet-related diseases in Ecuador and its possible relationship with Ecuadorian consumption habits. For that, mortality rates (2001-2008) associated with five different disease groups related to dietary factors (cancer of colon, cerebrovascular diseases, cardiovascular diseases, diabetes mellitus and liver diseases) were collected, analyzed and compared to consumption patterns in Ecuador. According to results, Ecuador has a low level of cancer of colon in comparison with developed countries (e.g. Spain). The group with the highest number of deaths corresponded to cardiovascular diseases followed by cerebrovascular diseases. The mortality study per province revealed that Amazonian provinces showed few deaths in relation to other provinces in Ecuador. This could be due to different factors including fails in the disease surveillance information systems, environmental factors and consumption patterns. In this sense, further investigation on native products consumption such as "chontaduro" might help to find valuable foods contributing to healthier Ecuadorian diet. These results, though preliminary, evidence that a major effort should be made by national and international organisations to collect data on consumption patterns and nutritional aspects of the Ecuadorian population in order to better support the development of effective food security and nutrition policies. Copyright © AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  13. Evaluation of the use of ICRP 60 dose conversion factors in a postclosure assessment of a deep geological disposal system

    International Nuclear Information System (INIS)

    Palattao, M.V.B.; Hajas, W.C.; Goodwin, B.W.

    1997-05-01

    An Environmental Impact Statement (EIS) of the concept for disposal of Canada's nuclear fuel waste was completed in 1994 and is currently under review by an independent Review Panel. This EIS included a postclosure assessment case study to estimate the annual effective dose equivalent in sieverts per year to members of the public; these estimates were obtained using dose conversion factors (DCFS) based on the 1977 recommendations of the International Commission on Radiation Protection (ICRP). However, in 1990 the ICRP revised these recommendations based on additional biological information and developments in radiation protection. This report describes a study of how the more recent recommendations of the ICRP would affect the results of the postclosure assessment case study presented in the EIS. The report includes a theoretical description of how DCFs are used and a comparison of results from computer simulations using the 1977 and the 1990 ICRP recommendations. In the EIS case study, which was based on the 1977 ICRP recommendations, the total dose rate to a member of the critical group is more than six orders of magnitude below the dose rate associated with the regulatory criterion for individual radiological risk. The total dose rate to 10 4 years is dominated by 129 I, with smaller contributions from 36 C1 and 14 C. If the 1990 ICRP recommendations were implemented, the total dose rate would be mostly affected by the new DCF for 129 I, and would increase by about 67%. Even with this increase, the total dose rate would still remain many orders of magnitude lower than the dose rate associated with the regulatory risk criterion. (author)

  14. Asthma-Related School Absenteeism, Morbidity, and Modifiable Factors.

    Science.gov (United States)

    Hsu, Joy; Qin, Xiaoting; Beavers, Suzanne F; Mirabelli, Maria C

    2016-07-01

    Asthma is a leading cause of chronic disease-related school absenteeism. Few data exist on how information on absenteeism might be used to identify children for interventions to improve asthma control. This study investigated how asthma-related absenteeism was associated with asthma control, exacerbations, and associated modifiable risk factors using a sample of children from 35 states and the District of Columbia. The Behavioral Risk Factor Surveillance System Child Asthma Call-back Survey is a random-digit dial survey designed to assess the health and experiences of children aged 0-17 years with asthma. During 2014-2015, multivariate analyses were conducted using 2006-2010 data to compare children with and without asthma-related absenteeism with respect to clinical, environmental, and financial measures. These analyses controlled for sociodemographic and clinical characteristics. Compared with children without asthma-related absenteeism, children who missed any school because of asthma were more likely to have not well controlled or very poorly controlled asthma (prevalence ratio=1.50; 95% CI=1.34, 1.69) and visit an emergency department or urgent care center for asthma (prevalence ratio=3.27; 95% CI=2.44, 4.38). Mold in the home and cost as a barrier to asthma-related health care were also significantly associated with asthma-related absenteeism. Missing any school because of asthma is associated with suboptimal asthma control, urgent or emergent asthma-related healthcare utilization, mold in the home, and financial barriers to asthma-related health care. Further understanding of asthma-related absenteeism could establish how to most effectively use absenteeism information as a health status indicator. Published by Elsevier Inc.

  15. Clinical experience with fixed bimonthly aflibercept dosing in treatment-experienced patients with neovascular age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Khanani AM

    2015-07-01

    Full Text Available Arshad M Khanani Sierra Eye Associates, Reno, NV, USA Purpose: To evaluate the durability of fixed bimonthly dosing of intravitreal aflibercept for neovascular age-related macular degeneration.Methods: Records of 16 patients were retrospectively reviewed. Patients received three initial 2.0 mg monthly doses of aflibercept then 8-weekly doses according to the product label. Best-corrected visual acuity (Early Treatment Diabetic Retinopathy Study [ETDRS] letters, central macular thickness, fluid on optical coherence tomography, and pigment epithelial detachment (PED were measured.Results: Prior to starting aflibercept, 13 patients had subretinal fluid (SRF, five had intraretinal fluid (IRF, four had PED, and baseline visual acuity (VA was 62 approximate ETDRS letters. Following the monthly dosing, seven patients had no improvement or decreased VA, ten patients still had SRF/IRF, and PED had worsened in one patient. At Visit 4, an average of 6.8 weeks after Visit 3, VA had decreased in seven patients, SRF/IRF had increased in 12 patients, and PED had returned in all patients who initially responded. Based on the presence of fluid after the initial monthly injections, 12 patients could not be extended to fixed bimonthly dosing.Conclusion: This case series adds to the growing body of evidence on the need for flexible dosing schedules for the personalized treatment of neovascular age-related macular degeneration. Keywords: age-related macular degeneration, AMD, bimonthly, regimen, aflibercept, case studies, retinal fluid

  16. Influence of environmental factors on some high dose dosimeter responses in Yazd Radiation Processing Center

    International Nuclear Information System (INIS)

    Ziaie, F.; Tahami, S.M.; Zareshahi, H.; Lanjanian, H.; Durrani, S.A.

    2008-01-01

    In this paper attempt has been made to study the influence of temperature and UV light (exist in laboratory due to the fluorescent light or diffused sunlight) on some high dose dosimetry responses that are being used in Yazd Radiation Processing Center (YRPC). The CTA, FWT and B3 film dosimeters were used for this investigation. The correction of the read response of the dosimeters to the real absorbed dose values is very important especially while we need to measure the precise dose values in the medical devices and in foodstuff materials. Yazd city is near to the desert, and so temperature and UV light due to the sun are very different in compare to other cities. Therefore, we tried to investigate the temperature and UV light effects on the dosimeter response in different doses and obtain its variation as a function of temperature (up to ∼60 0 C) and exposure time (up to ∼1 year), respectively

  17. Impact of respiratory motion on variable relative biological effectiveness in 4D-dose distributions of proton therapy.

    Science.gov (United States)

    Ulrich, Silke; Wieser, Hans-Peter; Cao, Wenhua; Mohan, Radhe; Bangert, Mark

    2017-11-01

    Organ motion during radiation therapy with scanned protons leads to deviations between the planned and the delivered physical dose. Using a constant relative biological effectiveness (RBE) of 1.1 linearly maps these deviations into RBE-weighted dose. However, a constant value cannot account for potential nonlinear variations in RBE suggested by variable RBE models. Here, we study the impact of motion on recalculations of RBE-weighted dose distributions using a phenomenological variable RBE model. 4D-dose calculation including variable RBE was implemented in the open source treatment planning toolkit matRad. Four scenarios were compared for one field and two field proton treatments for a liver cancer patient assuming (α∕β) x  = 2 Gy and (α∕β) x  = 10 Gy: (A) the optimized static dose distribution with constant RBE, (B) a static recalculation with variable RBE, (C) a 4D-dose recalculation with constant RBE and (D) a 4D-dose recalculation with variable RBE. For (B) and (D), the variable RBE was calculated by the model proposed by McNamara. For (C), the physical dose was accumulated with direct dose mapping; for (D), dose-weighted radio-sensitivity parameters of the linear quadratic model were accumulated to model synergistic irradiation effects on RBE. Dose recalculation with variable RBE led to an elevated biological dose at the end of the proton field, while 4D-dose recalculation exhibited random deviations everywhere in the radiation field depending on the interplay of beam delivery and organ motion. For a single beam treatment assuming (α∕β) x  = 2 Gy, D 95 % was 1.98 Gy (RBE) (A), 2.15 Gy (RBE) (B), 1.81 Gy (RBE) (C) and 1.98 Gy (RBE) (D). The homogeneity index was 1.04 (A), 1.08 (B), 1.23 (C) and 1.25 (D). For the studied liver case, intrafractional motion did not reduce the modulation of the RBE-weighted dose postulated by variable RBE models for proton treatments.

  18. Radiation optic neuropathy after megavoltage external-beam irradiation: Analysis of time-dose factors

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Million, R.R.

    1994-01-01

    To investigate the risk of radiation-induced optic neuropathy according to total radiotherapy dose and fraction size, based on both retrospective and prospectively collected data. Between October 1964 and May 1989, 215 optic nerves in 131 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 21 years). The clinical end point was visual acuity of 20/100 or worse as a result of optic nerve injury. Anterior ischemic optic neuropathy developed in five nerves (at mean and median times of 32 and 30 months, respectively, and a range of 2-4 years). Retrobulbar optic neuropathy developed in 12 nerves (at mean and median times of 47 and 28 months, respectively, and a range of 1-14 years). No injuries were observed in 106 optic nerves that received a total dose of <59 Gy. Among nerves that received doses of ≥ 60 Gy, the dose per fraction was more important than the total dose in producing optic neuropathy. The 15-year actuarial risk of optic compared with 47% when given in fraction sizes ≥1.9 Gy. The data also suggest an increased risk of optic nerve injury with increasing age. As there is no effective treatment of radiation-induced optic neuropathy, efforts should be directed at its prevention by minimizing the total dose, paying attention to the dose per fraction to the nerve, and using reduced field techniques where appropriate to limit the volume of tissues that receive high-dose irradiation. 32 refs., 5 figs., 5 tabs

  19. Radioprotection by murine and human tumor-necrosis factor; Dose-dependent effects on hematopoiesis in the mouse

    Energy Technology Data Exchange (ETDEWEB)

    Sloerdal, L; Muench, M O; Warren, D J; Moore, M A.S. [James Ewing Laboratory of Developmental Hematopoiesis, Memorial Sloan-Kettering Cancer Center, New York (USA)

    1989-01-01

    Tumor-necrosis factor (TNF) has been shown to confer significant radioprotection in murine models. Herein, we demonstrate a dose-dependent enhancement of hematological recovery when single doses of either murine or human recombinant TNF are administered prior to irradiation. In addition to its action upon leukocytes and erythocytes, TNF also alleviates radiation-induced thrombocytopenia in the mouse. These effects on circulating blood constituents are further reflected in increased numbers of both primitive (CFU-S) and more differentiated (CFU-GM, CFU-Mega) hematopoietic progenitors in TNF-treated animals. This suggests that TNF exerts it radioprotective effects on a pool of primitive multi-potential hematopoietic cells. (author).

  20. Experimental determination of the angular dependence factor for the dose equivalent for photons in calibration phantoms of PMMA

    International Nuclear Information System (INIS)

    Lund, E.; Carlsson, C.A.; Pernicka, F.

    1994-01-01

    The conversion coefficients from air kerma to dose equivalent at a depth of 10 mm in both a spherical and a slab phantom of PMMA have been determined for the X ray qualities: 40, 80 and 295 kV, ISO 'narrow' spectra; and for 137 Cs γ rays. The angular dependence factors have been experimentally determined for the same qualities and for different angles between 0 o and 180 o . The absorbed doses have been measured with thermoluminescence LiF dosemeters. The conversion coefficients and the angular dependence factors are generally found to agree well with calculated ones. Some minor discrepancies are found for the angular dependence factors and the 30 x 30 x 15 cm 3 PMMA slab phantom. (Author)

  1. Organizational factors related to occupational accidents in construction.

    Science.gov (United States)

    Filho, J M Jackson; Fonseca, E D; Lima, F P A; Duarte, F J C M

    2012-01-01

    The purpose of this paper is to understand the influence of organizational factors on occupational accident causation. A field study was undertaken and focused on the phase of concreting the floors of a residential block in a building project in Brazil. The methodological approach was based on the analysis of carpenters' work practices and of the workers' accounts of minor falls. Observations were noted on work practices over this stage. Furthermore, interviews were conducted with the workers hired by the subcontractors and with professionals working for the main contractor. The results show that falls were related to the introduction of new building technology and its use by the workforce. The production planning and organization of activities by the subcontracted firms also led to temporary demands that were additional determining factors for falls on site. The work analysis reveals the need to consider organizational factors in prevention practices.

  2. Risk Factors and Biomarkers of Age-Related Macular Degeneration

    Science.gov (United States)

    Lambert, Nathan G.; Singh, Malkit K.; ElShelmani, Hanan; Mansergh, Fiona C.; Wride, Michael A.; Padilla, Maximilian; Keegan, David; Hogg, Ruth E.; Ambati, Balamurali K.

    2016-01-01

    A biomarker can be a substance or structure measured in body parts, fluids or products that can affect or predict disease incidence. As age-related macular degeneration (AMD) is the leading cause of blindness in the developed world, much research and effort has been invested in the identification of different biomarkers to predict disease incidence, identify at risk individuals, elucidate causative pathophysiological etiologies, guide screening, monitoring and treatment parameters, and predict disease outcomes. To date, a host of genetic, environmental, proteomic, and cellular targets have been identified as both risk factors and potential biomarkers for AMD. Despite this, their use has been confined to research settings and has not yet crossed into the clinical arena. A greater understanding of these factors and their use as potential biomarkers for AMD can guide future research and clinical practice. This article will discuss known risk factors and novel, potential biomarkers of AMD in addition to their application in both academic and clinical settings. PMID:27156982

  3. Factors relating to age of onset in autism.

    Science.gov (United States)

    Short, A B; Schopler, E

    1988-06-01

    We examined the distribution of ages of onset of autism and related communication handicaps and assessed factors related to age of onset. Subjects were approximately 1,800 children seen at Division TEACCH (Treatment and Education of Autistic and related Communication handicapped CHildren) since 1970. Exact numbers of subjects varied with different analyses due to missing data. Data were gathered through direct assessment, interview, and questionnaire. Seventy-six percent of autistic children were identified by parents by 24 months of age, and 94% by 36 months. Families reporting early onset tended to seek help sooner and to be seen by TEACCH sooner. Early onset was most clearly related to severity as measured by IQ and ratings on the Childhood Autism Rating Scale (Schopler, Reichler, & Renner, 1986). The findings support the treatment of age of onset of autism by DSM-III-R (American Psychiatric Association, 1987).

  4. Radioablation of liver malignancies with interstitial high-dose-rate brachytherapy. Complications and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mohnike, Konrad; Wolf, Steffen; Damm, Robert; Seidensticker, Max; Seidensticker, Ricarda; Fischbach, Frank; Pech, Maciej; Ricke, Jens [Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany); Peters, Nils; Hass, Peter; Gademann, Guenther [Otto-von-Guericke-Universitaet, Klinik fuer Strahlentherapie, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany)

    2016-05-15

    To evaluate complications and identify risk factors for adverse events in patients undergoing high-dose-rate interstitial brachytherapy (iBT). Data from 192 patients treated in 343 CT- or MRI-guided interventions from 2006-2009 at our institution were analyzed. In 41 %, the largest tumor treated was ≥ 5 cm, 6 % of the patients had tumors ≥ 10 cm. Prior to iBT, 60 % of the patients had chemotherapy, 22 % liver resection, 19 % thermoablation or transarterial chemoembolization (TACE). Safety was the primary endpoint; survival data were obtained as the secondary endpoints. During follow-up, MRI or CT imaging was performed and clinical and laboratory parameters were obtained. The rate of major complications was below 5 %. Five major bleedings (1.5 %) occurred. The frequency of severe bleeding was significantly higher in patients with advanced liver cirrhosis. One patient developed signs of a nonclassic radiation-induced liver disease. In 3 patients, symptomatic gastrointestinal (GI) ulcers were detected. A dose exposure to the GI wall above 14 Gy/ml was a reliable threshold to predict ulcer formation. A combination of C-reactive protein ≥ 165 mg/l and/or leukocyte count ≥ 12.7 Gpt/l on the second day after the intervention predicted infection (sensitivity 90.0 %; specificity 92.8 %.) Two patients (0.6 %) died within 30 days. Median overall survival after the first liver treatment was 20.1 months for all patients and the local recurrence-free surviving proportion was 89 % after 12 months. Image-guided iBT yields a low rate of major complications and is effective. (orig.) [German] Evaluierung der Komplikationsrate und Identifizierung von Risikofaktoren fuer Komplikationen und Nebenwirkungen bei Patienten mit Lebermalignomen, die mit der hochdosierten interstitiellen Brachytherapie (iBT) behandelt wurden. Von 2006 bis 2009 wurden 192 Patienten in 343 CT- oder MRT-gefuehrten Interventionen behandelt und deren Daten ausgewertet. Der groesste behandelte Tumor war in

  5. Medical residents' job satisfaction and their related factors.

    Science.gov (United States)

    Chung, Eun-Kyung; Han, Eui-Ryoung; Woo, Young-Jong

    2013-03-01

    This study was conducted to investigate medical residents' job satisfaction and their related factors to improve the quality of residency program. The study subjects were 159 medical residents being trained at Chonnam National University Hospital, South Korea, in 2011. The participants were asked to complete a short form Minnesota satisfaction questionnaire (MSQ). The mean score for 20 items on the short form MSQ varied between 2.91 and 3.64 on a 5-point Likert scale. The assessment of related factors with job satisfaction revealed that medical residents had higher levels for job satisfaction, particularly those who were women (beta=0.200, p=0.022), and those who had mentorship experience (beta=0.219, p=0.008). This study results indicate that we should expand and support the mentorship program during medical residency to promote job satisfaction.

  6. Evironmental assessment factors relating to reprocessing of spent nuclear fuel

    International Nuclear Information System (INIS)

    1978-05-01

    This document is in two parts. Part I presents the criteria and evaluation factors, based primarily on US experience, which may be used to carry out an environmental assessment of spent fuel reprocessing. The concept of As Low as is Reasonably Achievable (ALARA) is introduced in limiting radiation exposure. The factors influencing both occupational and general public radiation exposure are reviewed. Part II provides information on occupational and general public radiation exposure in relation to reprocessing taken from various sources including UNSCEAR and GESMO. Some information is provided in relation to potential accidents at reprocessing or MOX fuel refabrication plants. The magnitude of the services, energy, land use and non-radiological effluents for the reference design of reprocessing plant are also presented

  7. Building-related risk factors and work-related lower respiratory symptoms in 80 office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Naco, G.M.; Wilcox, T.G.; Sieber, W.K.

    2002-01-01

    We assessed building-related risk factors for lower respiratory symptoms in office workers. The National Institute for Occupational Safety and Health in 1993 collected data during indoor environmental health investigations of workplaces. We used multivariate logistic regression analyses to assess relationships between lower respiratory symptoms in office workers and risk factors plausibly related to microbiologic contamination. Among 2,435 occupants in 80 office buildings, frequent, work-related multiple lower respiratory symptoms were strongly associated, in multivariate models, with two risk factors for microbiologic contamination: poor pan drainage under cooling coils and debris in outside air intake. Associations tended to be stronger among those with a history of physician-diagnosed asthma. These findings suggest that adverse lower respiratory health effects from indoor work environments, although unusual, may occur in relation to poorly designed or maintained ventilation systems, particularly among previously diagnosed asthmatics. These findings require confirmation in more representative buildings.

  8. Building-related risk factors and work-related lower respiratory symptoms in 80 office buildings

    International Nuclear Information System (INIS)

    Mendell, M.J.; Naco, G.M.; Wilcox, T.G.; Sieber, W.K.

    2002-01-01

    We assessed building-related risk factors for lower respiratory symptoms in office workers. The National Institute for Occupational Safety and Health in 1993 collected data during indoor environmental health investigations of workplaces. We used multivariate logistic regression analyses to assess relationships between lower respiratory symptoms in office workers and risk factors plausibly related to microbiologic contamination. Among 2,435 occupants in 80 office buildings, frequent, work-related multiple lower respiratory symptoms were strongly associated, in multivariate models, with two risk factors for microbiologic contamination: poor pan drainage under cooling coils and debris in outside air intake. Associations tended to be stronger among those with a history of physician-diagnosed asthma. These findings suggest that adverse lower respiratory health effects from indoor work environments, although unusual, may occur in relation to poorly designed or maintained ventilation systems, particularly among previously diagnosed asthmatics. These findings require confirmation in more representative buildings

  9. Marital Relationship and Its Associated Factors in Veterans Exposed to High Dose Chemical Warfare Agents

    Directory of Open Access Journals (Sweden)

    Shervin Assari

    2008-06-01

    Full Text Available Objective: The aim of this study was to determine the associates of marital relationship in mustard exposed veterans.Materials and Methods: Two hundred ninety two married Iranian mustard exposed veterans, who had been exposed to single high dose mustard gas in Iraq-Iran war, were assessed for marital adjustment with Revised Dyadic Adjustment Scale (RDAS. Census sampling was done. The patients' quality of life (SF-36, spirometric measures and war related data were also extracted.Results: A total of 189 subjects (65% completed our study. The mean (±SD of the RDAS Total score, RDAS Dyadic Consensus , RDAS Affectional Expression, RDAS Dyadic Satisfaction , and RDAS Dyadic Cohesion were 50.61 (8.16, 16.67 (2.77, 7.62 (1.84, 14.76 (3.39, and 11.54 (3.79, respectively. RDAS Dyadic satisfaction was correlated with SF-36 and all its sub-scores (p<0.05. RDAS total score showed significant correlation with SF-36 total score and most of its sub-scores (p<0.05. RDAS affective expression was significantly correlated with role limitation, social function, general mental health, vitality, General health perceptions, physical composite score (PCS and mental composite score (MCS (p<0.05. RDAS dyadic consensus was not correlated with any SF-36 sub-scores.Conclusion: Veterans health team including physicians, psychologists and/or psychiatrists should know that poorer marital satisfaction is linked with lower quality of life scores, late after mustard exposure, although marital relationship is independent of spirometric findings, age, duration from exposure and comorbidity score.

  10. Factors relating to the perceived management of emergency situations

    DEFF Research Database (Denmark)

    Birkvad Rasmussen, Maria; Tolsgaard, Martin G; Dieckmann, Peter

    2014-01-01

    -workers familiarity with ALS principles', 'own confidence as ALS-provider' and 'own social/inter-personal skills'. CONCLUSION: The results of this survey emphasise that ALS providers' perceived ability to apply ALS skills were substantially affected by teamwork skills and co-workers' skills. Team related factors...... associated with successful outcome were related to clear role distribution, clear inter-personal communication and attentive listening, as well as respectful behaviour and positive team atmosphere. Although intensity of setting was attributed to ability to apply ALS principles, this did not affect management...

  11. Contributing factors to the use of health-related websites.

    Science.gov (United States)

    Hong, Traci

    2006-03-01

    This study explicates the influence of audience factors on website credibility and the subsequent effect that credibility has on the intention to revisit a site. It does so in an experimental setting in which participants were given two health-related search tasks. Reliance on the web for health-related information positively influenced website credibility in both searches. Knowledge was a significant predictor for the search task that required more cognitive ability. Of the credibility dimensions, trust/expertise and depth were significant predictors of intention to revisit a site in both searches. Fairness and goodwill were nonsignificant predictors in both searches.

  12. TU-F-CAMPUS-T-05: A Cloud-Based Monte Carlo Dose Calculation for Electron Cutout Factors

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, T; Bush, K [Stanford School of Medicine, Stanford, CA (United States)

    2015-06-15

    Purpose: For electron cutouts of smaller sizes, it is necessary to verify electron cutout factors due to perturbations in electron scattering. Often, this requires a physical measurement using a small ion chamber, diode, or film. The purpose of this study is to develop a fast Monte Carlo based dose calculation framework that requires only a smart phone photograph of the cutout and specification of the SSD and energy to determine the electron cutout factor, with the ultimate goal of making this cloud-based calculation widely available to the medical physics community. Methods: The algorithm uses a pattern recognition technique to identify the corners of the cutout in the photograph as shown in Figure 1. It then corrects for variations in perspective, scaling, and translation of the photograph introduced by the user’s positioning of the camera. Blob detection is used to identify the portions of the cutout which comprise the aperture and the portions which are cutout material. This information is then used define physical densities of the voxels used in the Monte Carlo dose calculation algorithm as shown in Figure 2, and select a particle source from a pre-computed library of phase-spaces scored above the cutout. The electron cutout factor is obtained by taking a ratio of the maximum dose delivered with the cutout in place to the dose delivered under calibration/reference conditions. Results: The algorithm has been shown to successfully identify all necessary features of the electron cutout to perform the calculation. Subsequent testing will be performed to compare the Monte Carlo results with a physical measurement. Conclusion: A simple, cloud-based method of calculating electron cutout factors could eliminate the need for physical measurements and substantially reduce the time required to properly assure accurate dose delivery.

  13. A phantom study on fetal dose reducing factors in pregnant patients with breast cancer during radiotherapy treatment

    Directory of Open Access Journals (Sweden)

    Akın Ogretici

    2017-01-01

    Full Text Available Purpose: This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs and simple shielding for intensity modulated radiation therapy technique. Materials and Methods: TPS factor was evaluated with two different planning algorithms: Anisotropic analytical algorithm and Acuros XB (external beam. To evaluate the shielding factor, a standard radiological purpose lead apron was chosen. For both studies, thermoluminescence dosimeters were used to measure the point dose, and an Alderson RANDO-phantom was used to simulate a female pregnant patient in this study. Thirteen measurement points were chosen in the 32nd slice of the phantom to cover all possible locations of a fetus up to 8th week of gestation. Results: The results show that both of the TPS algorithms are incapable of calculating the fetal doses, therefore, unable to reduce them at the planning stage. Shielding with a standard lead apron, however, showed a slight radiation protection (about 4.7% to the fetus decreasing the mean fetal dose from 84.8 mGy to 80.8 mGy, which cannot be disregarded in case of fetal irradiation. Conclusions: Using a lead apron for shielding the abdominal region of a pregnant patient during breast irradiation showed a minor advantage; however, its possible side effects (i.e., increased scattered radiation and skin dose should also be investigated further to solidify its benefits.

  14. Effect of low dose radiation on expression of hematopoietic growth factors secreted by human mesenchymal stem cells from bone marrow

    International Nuclear Information System (INIS)

    Yang Yan; Wang Guanjun; Zhu Jingyan; Wang Juan

    2008-01-01

    Objective: To study the changes of hematopoietic growth factors secreted by human mesenchymal stem cells from bone marrow (BM-MSC) pretreated with low dose radiation (LDR). Methods: The cultured P4 and P5 BM-MSCs were exposed to X rays at the doses of 50, 75 and 100 mGy (dose rate 12.5 mGy·min -1 ). The changes of levels of stem cell factor (SCF), IL-6, macrophage colony-stimulating factor (M-CSF) secreted by BM- MSCs pretreated with LDR were determined by ELISA method. Results: As compared with control group at the same time, the levels of SCF in experimental group had a tendency of increasing after 24 h and 48 h radiation, but only in 75 mGy group the SCF level was obviously increased (P<0.05). The levels of IL-6 in 50 and 75 mGy groups at 24 h and 48 h, in 100 mGy group at 24 h were obviously increased compared with control group (P< 0.05). The levels of M-CSF in all the groups at 24 h, 48 h and 72 h except for the 50 mGy dose at 72 h were also increased (P<0.05), it increased markedly in 75 mGy dose group at 72 h. Conclusion: LDR has hormesis effect on BM-MSCs. After LDR, the BM-MSCs grow faster and in a certain phase the expression levels of hematopoietic growth factors are increased. (authors)

  15. Individual, home and neighborhood factors related to childhood obesity intervention

    OpenAIRE

    Silva, Fabiana Brito

    2016-01-01

    Obesity is one of the most pressing global population health issues, and importantly one that affects racial/ethnic minorities and those of low socioeconomic status disproportionately. Obesity tracks from childhood into adulthood and is related to serious medical and economic consequences throughout the life course. Childhood obesity is well recognized as a complex and multifaceted problem influenced by broader social, geographic and environmental factors. A social ecological framework that i...

  16. Morale as a Protection Factor against Mission Related Stress

    Science.gov (United States)

    2006-04-01

    Inventory [34]. Morale as a Protection Factor against Mission Related Stress RTO-MP HFM-134 10 - 7 - Inventario de Valoración y Afrontamiento...17-37. [27] Miguel-Tobal, J. J. and Cano Vindel, A. (1986). Inventario de Situaciones y Respuestas de Ansiedad. Madrid: Tea Ediciones. (2ª Edic...Psychology, 56, 2, 267-283. [35] Cano Vindel, A. and Miguel-Tobal, J. J. (1992). Inventario de Valoración y Afrontamiento (IVA). Mimeo: Universidad

  17. Deployment-related risk factors of low back pain

    DEFF Research Database (Denmark)

    Nissen, Lars Ravnborg; Marott, Jacob Louis; Gyntelberg, Finn

    2014-01-01

    Where much is known about the consequences of spinal and low back pain (LBP) during military deployments, there is lesser knowledge of risk factors for LBP among the deployed forces. The objective of this study was to identify deployment-related exposures associated with LBP. The study was a ques...... their subordinates and involve medical personnel, especially deployed physiotherapists, by giving advice to soldiers of different military occupational specialties on how to optimize ergonomics at work....

  18. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  19. Dose rate and fractionation: Relative importance in radiation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Tarbell, N.J.; Rosenblatt, M.; Mauch, P.; Hellman, S.

    1987-01-01

    The optimal dose rate and fractionation schedules for total body irradiation (TBI) in bone marrow transplantation (BMT) are presently unknown. This study compares several fractionation and dose rate schedules that are currently in clinical use. C/sub 3/H/HeJ were given TBI and the bone marrow survival fraction was calculated using the CFU's assay. Irradiation was given as low dose rate (LDR) at 5 cGy/min or high dose rate (HDR) at 80 cGy/min, in single fraction (SF) and fractionated (FX) regimens. These results indicate no increase in survival for the normal bone marrow stem cells with fractionation either at high or low dose-rates. In fact, fractionation seemed to decrease the bone marrow survival over single fraction radiation

  20. Analysis of the main factors affecting the evaluation of the dose in workplaces: the case of tourist caves

    International Nuclear Information System (INIS)

    Sainz, C.; Santiago Quindos, L.; Fuente, I.; Nicolas, J.; Quindos, L.

    2006-01-01

    Since 2001, Spanish law incorporated EURATOM basic standards for radiological protection, which include a request at the European Communities Member States to determine the working places on which exposure to natural radiation is significant. On Title VII (BOE 178/2001) radiation coming from natural sources has analogous role than radiation emitted from artificial ones used to. High concentrations of radon exist in several workplaces like tourist caves mainly because of the low ventilation rates existing at these enclosures. In this sense, in its 1990 publication, the ICRP recommended that high exposures of radon in workplace could be regarded as the responsibility of the operating management and should be considered as occupational exposure. In developed caves in which guides provide tours for the general public great care is needed for taking remedial actions concerning radon, because in some circumstances forced ventilation may alter the humidity inside the cave affecting the some of the formations or paintings that attract tourists. Tourist guides can work about 1900 hours per year, so the only option to protect them and other cave workers from radon exposure is to apply an appropriate system of radiation protection mainly based on limitation of exposure by restricting the amount of time spent in the cave. The information needed for carrying out the above mentioned protecting actions is related with the specific characteristics of the cave concerning the behaviour of radon and it decay products. In order to perform a precise effective dose calculation, factors like unattached progeny fraction (fp), equilibrium factor (F) and particle concentration (Z) are of main importance. One of the specific characteristic of the caves is the high unattached fraction due to very low particle concentration. The fp values can be higher than 0.1, for places with low ventilation and without additional aerosol sources, with Z -3 .In this work the results of the first stage of

  1. Analysis of the main factors affecting the evaluation of the dose in workplaces: the case of tourist caves

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, C.; Santiago Quindos, L.; Fuente, I.; Nicolas, J.; Quindos, L. [Cantabria Univ., Dept. of Medical Physics. RADON Group, Faculty of Medicine, (Spain)

    2006-07-01

    Since 2001, Spanish law incorporated EURATOM basic standards for radiological protection, which include a request at the European Communities Member States to determine the working places on which exposure to natural radiation is significant. On Title VII (BOE 178/2001) radiation coming from natural sources has analogous role than radiation emitted from artificial ones used to. High concentrations of radon exist in several workplaces like tourist caves mainly because of the low ventilation rates existing at these enclosures. In this sense, in its 1990 publication, the ICRP recommended that high exposures of radon in workplace could be regarded as the responsibility of the operating management and should be considered as occupational exposure. In developed caves in which guides provide tours for the general public great care is needed for taking remedial actions concerning radon, because in some circumstances forced ventilation may alter the humidity inside the cave affecting the some of the formations or paintings that attract tourists. Tourist guides can work about 1900 hours per year, so the only option to protect them and other cave workers from radon exposure is to apply an appropriate system of radiation protection mainly based on limitation of exposure by restricting the amount of time spent in the cave. The information needed for carrying out the above mentioned protecting actions is related with the specific characteristics of the cave concerning the behaviour of radon and it decay products. In order to perform a precise effective dose calculation, factors like unattached progeny fraction (fp), equilibrium factor (F) and particle concentration (Z) are of main importance. One of the specific characteristic of the caves is the high unattached fraction due to very low particle concentration. The fp values can be higher than 0.1, for places with low ventilation and without additional aerosol sources, with Z < 4 103 particle cm{sup -3}.In this work the results

  2. Radiation exposure dose on persons engaged in radiation-related industries in Korea

    International Nuclear Information System (INIS)

    Lim, Bong Sik

    2006-01-01

    This study investigated the status of radiation exposure doses since the establishment of the 'Regulations on Safety Management of Diagnostic Radiation Generation Device' in January 6, 1995. The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organization, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Among 57,136 men were 40,870 (71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors (22.7%), nurse (2.9%) and others (24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv (limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. The total exposure per worker was significantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided

  3. Inverse dose-rate-effects on the expressions of extra-cellular matrix-related genes in low-dose-rate γ-ray irradiated murine cells

    International Nuclear Information System (INIS)

    Sugihara, Takashi; Tanaka, Kimio; Oghiso, Yoichi; Murano, Hayato

    2008-01-01

    Based on the results of previous microarray analyses of murine NIH3T3/PG13Luc cells irradiated with continuous low-dose-rate (LDR) γ-ray or end-high-dose-rate-irradiations (end-HDR) at the end of the LDR-irradiation period, the inverse dose-rate-effects on gene expression levels were observed. To compare differences of the effects between LDR-irradiation and HDR-irradiation, HDR-irradiations at 2 different times, one (ini-HDR) at the same time at the start of LDR-irradiation and the other (end-HDR), were performed. The up-regulated genes were classified into two types, in which one was up-regulated in LDR-, ini-HDR-, and end-HDR irradiation such as Cdkn1a and Ccng1, which were reported as p53-dependent genes, and the other was up-regulated in LDR- and ini-HDR irradiations such as pro-collagen TypeIa2/Colla2, TenascinC/Tnc, and Fibulin5/Fbln5, which were reported as extra-cellular matrix-related (ECM) genes. The time dependent gene expression patterns in LDR-irradiation were also classified into two types, in which one was an early response such as in Cdkn1a and Ccng1 and the other was a delayed response such as the ECM genes which have no linearity to total dose. The protein expression pattern of Cdkn1a increased dose dependently in LDR- and end-HDR-irradiations, but those of p53Ser15/18 and MDM2 in LDR-irradiations were different from end-HDR-irradiations. Furthermore, the gene expression levels of the ECM genes in embryonic fibroblasts from p53-deficient mice were not increased by LDR- and end-HDR-irradiation, so the delayed expressions of the ECM genes seem to be regulated by p53. Consequently, the inverse dose-rate-effects on the expression levels of the ECM genes in LDR- and end-HDR-irradiations may be explained from different time responses by p53 status. (author)

  4. Dose-volume histogram analysis of hepatic toxicity related to carbon ion radiation therapy of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yasuda, Shigeo; Kato, Hirotoshi; Tsujii, Hitohiko; Mizoe, Junetsu

    2005-01-01

    The purpose of this study is to analyze the correlation of hepatic toxicity with dose-volume factors of carbon ion radiotherapy in the liver. Forty-nine patients with hepatocellular carcinoma were treated with carbon ion radiotherapy delivered in 4 fractions over 4 to 7 days. Six patients received a total dose of 48 GyE and 43 received 52.8 GyE. The correlation of various blood biochemistry data with dose-volume histogram (DVH) data in non-cancerous liver were evaluated. The strongest significant correlation was seen between percent volume of non-cancerous liver with radiation dose more than 11 GyE (V 11 GyE ) and elevation of serum glutamic oxaloacetic transaminase (GOT) level as early adverse response after carbon ion beam radiation therapy (p=0.0003). In addition, significant correlation between DVH data and change of several other blood biochemistry data were also revealed in early phase. In late phase after carbon ion radiotherapy, the strongest significant correlation was seen between decrease of platelet count and V 26GyE (p=0.015). There was no significant correlation between other blood biochemistry data and DVH data in the late phase. It was suggested that dose-volume factors of carbon ion radiotherapy influenced only transient aggravation of liver function, which improved in the long term after irradiation. (author)

  5. Quantitative analysis of the factors responsible for over or under dose of 131I therapy patients of hyperthyroidism

    International Nuclear Information System (INIS)

    Muhammad, W.; Faaruq, S.; Hussain, A.; Kakakhail, M. B.; Fatmi, S.; Matiullah

    2008-01-01

    Radioiodine ( 131 I) therapy has been in use for more than 60 y. Several protocols have been suggested and used for prescribing the activity to be administered to the patients for the treatment of hyperthyroidism; application of these protocols may result in an under or over dose of the hyperthyroid patients. The main objective of this study was to carry out quantitative analysis of the factors responsible for possible under or over dosage of the patients. In this regard, a total of 59 patients [15 diffuse goitre (DG) and 44 nodular goitre (NG) cases] were studied. In order to compare the thyroid doses calculated by using different protocols, the dosimetric approach was followed. 131 I uptakes were measured after 24 and 48 h, respectively, by giving 0.5 MBq of 131 I to each patient. Thyroid mass and effective half-life were also calculated for each patient and the variations in the thyroid doses were analysed. According to the results 28 and 54% patients were under dosed and 72 and 46% patients were over dosed with DG and NG, respectively. The protocols, which have not taken into account the thyroid mass, multi pre-therapeutic 131 I uptakes and the effective half-life of 131 I of the individual patient, showed a higher degree of deviation from the required thyroid dose. Besides these parameters, some fundamental factors such as radiosensitivity, previous exposure to thyroid drugs and duration of the disease are recommended to be incorporated, which can certainly affect the clinical out comes. (authors)

  6. Bicycling-related accidents and factors contributing to injury

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Perez, L.M.; Wideberg, J.; Gonzalez Perez-Somarriba, B.

    2016-07-01

    Objective: This study was conducted to find the epidemiological characteristics of bicycling-related maxillofacial fractures in a defined population, and identify factors contributing to injury. Methodology: A prospective study was carried out involving patients presenting with maxillofacial fractures sustained in bicycling-related accidents. Results: Between 908 of all cycling accidents attending for medical treatment, 122 patients (13% of all cycling accidents) were admitted with facial fractures between 2007 and 2014. Male and female ratio was 2.6:1, and the mean age was 29.4 years (standard deviation: 12.8, range: 12-79 years). Causes of injury included collisions (63%) and accidental falls (37%). The fracture patterns seen were mandibular (49%), zygomatic (32%), orbital (13%), nasal (7%), maxillary (2%), and frontal (2%). Condylar fractures were the most common of the mandibular fractures (63%). The most frequently observed concomitant lesions were orthopedic injuries. Conclusions: Bicycling-related maxillofacial injuries are common and therefore important to identify in order to design a sustainable transport system and for units that provide assistance to traffic accident victims. Missed diagnosis or delayed treatment can lead to facial deformities and functional problems. Wearing protective helmets and the improvement of the helmets design is one aspect that would be of interest for the prevention of injuries. Keywords: Cycling; bicycle-related trauma; maxillofacial fractures; risk factors; helmets. (Author)

  7. Comprehensive analysis of the related factors of early hypothyroidism occurring in patients with Graves' disease after 131I treatment

    International Nuclear Information System (INIS)

    Tan Jian; Wang Peng; Zhang Lijuan; He Yajing; Wang Renfei

    2005-01-01

    Objective: To make a comprehensive analysis of the related factors of early hypothyroidism occurring in patients with Graves' disease after 131 I treatment. Methods: The information of 131 I treated Graves' disease was collected including general data, clinical observation, laboratory data, thyroid function test, etc. Then a retrospective statistical analysis was carried out, using cluster analysis, factor analysis, discriminant analysis, multivariate regression analysis, etc. Results: 1) Cluster analysis and factor analysis showed that among clinical observation such as clinical course, treatment course, patients' state and disease occurrance, the first three factors correlated highly; among laboratory data such as thyrotrophin receptor antibody (TRAb), thyroid-stimulating immunoglobulins (TSI), thyroglobulin antibody (TgAb) and thyroid microsomal antibody (TMAb), both the first two and the last two correlated highly, each two factors had the similar effect. 2) Fsher discriminant analysis showed that among the thyroid weight, the effective half life, the maximum 131 I uptake percentage, total dose of 131 I and the average dose of 131 I per gram of thyroid, the last one had the most predicting value for incidence of early hypothyroidism. 3) Logistic regression analysis showed that among all the related factors of early hypothyroidism occurred after 131 I treated Graves' disease, thyroid weight, average dose of 131 I per gram of thyroid, the maximum 131 I uptake percentage and the level of TSI were effective factors. Conclusions: The occurrence of early hypothyroidism for 131 I-treated Graves' disease is probably affected by many factors. If more factors are taken into consideration before therapy and the theraputic dose is well adjusted accordingly, it can reduce the incidence of early hypothroidism to a certain extent. (authors)

  8. Obesity related factors in school-aged children.

    Science.gov (United States)

    Soltani, Parvaneh Reza; Ghanbari, Atefeh; Rad, Afagh Hasanzadeh

    2013-05-01

    Overweight and obesity is becoming an increasingly prevalent problem in both developed and developing world, and is one of the most serious public health challenges of the 21(st) century. Although various studies demonstrated pediatric obesity-related factors, but, due to its ongoing hazardous effects, researchers aimed to assess obesity-related factors in school-aged children in Rasht, Iran. This was a case-control study which was performed in eight primary schools of Rasht. A cluster sampling method was used to select 320 students including 80 in case (BMI ≥85(th) percentile for age and gender) and 240 in control group (BMI = 5(th)-85(th) percentile for age and gender). Data were collected by a scale, a tape meter, and a form which consisted of obesity-related factors, and were analyzed by Chi-square, Mann-Whitney, and stepwise multivariate regression tests in SPSS 19. Findings showed that the mean and standard deviation of birth weight (g) in case and control groups were 3671 ± 5.64 and 190 ± 5.46, respectively (P = 0.000). 82.5% of case and 92.9% of control group had exclusive breastfeeding for 4-6 months (P = 0.024). Also, multivariate regression analysis indicated that birth weight, age, exclusive breastfeeding, and frequency of meals have significant effects on body mass index (BMI). It seems that more accurate interventions for primordial prevention are essential to reduce childhood obesity risk factors, including promotion of pre-pregnancy and prenatal care to have neonates who are appropriate for gestational age and also improving exclusive breastfeeding in the first 6 months of life. In addition, identifying children at risk for adolescent obesity provides physicians and midwives with an opportunity for earlier intervention with the goal of limiting the progression of abnormal weight gain.

  9. Variable effects of high-dose adrenaline relative to standard-dose adrenaline on resuscitation outcomes according to cardiac arrest duration.

    Science.gov (United States)

    Jeung, Kyung Woon; Ryu, Hyun Ho; Song, Kyung Hwan; Lee, Byung Kook; Lee, Hyoung Youn; Heo, Tag; Min, Yong Il

    2011-07-01

    Adjustment of adrenaline (epinephrine) dosage according to cardiac arrest (CA) duration, rather than administering the same dose, may theoretically improve resuscitation outcomes. We evaluated variable effects of high-dose adrenaline (HDA) relative to standard-dose adrenaline (SDA) on resuscitation outcomes according to CA duration. Twenty-eight male domestic pigs were randomised to the following 4 groups according to the dosage of adrenaline (SDA 0.02 mg/kg vs. HDA 0.2mg/kg) and duration of CA before beginning cardiopulmonary resuscitation (CPR): 6 min SDA, 6 min HDA, 13 min SDA, or 13 min HDA. After the predetermined duration of untreated ventricular fibrillation, CPR was provided. All animals in the 6 min SDA, 6 min HDA, and 13 min HDA groups were successfully resuscitated, while only 4 of 7 pigs in the 13 min SDA group were successfully resuscitated (p=0.043). HDA groups showed higher right atrial pressure, more frequent ventricular ectopic beats, higher blood glucose, higher troponin-I, and more severe metabolic acidosis than SDA groups. Animals of 13 min groups showed more severe metabolic acidosis and higher troponin-I than animals of 6 min groups. All successfully resuscitated animals, except two animals in the 13 min HDA group, survived for 7 days (p=0.121). Neurologic deficit score was not affected by the dose of adrenaline. HDA showed benefit in achieving restoration of spontaneous circulation in 13 min CA, when compared with 6 min CA. However, this benefit did not translate into improved long-term survival or neurologic outcome. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Factors related to the performance of Specialized Dental Care Centers

    Directory of Open Access Journals (Sweden)

    Flávia Christiane de Azevedo Machado

    2015-04-01

    Full Text Available The Specialized Dental Care Centers (SDCC have the mission to expand access to public medium complexity dental care and support the primary health care actions at this level of complexity. However, it is necessary to ensure the quality of services and to evaluate such services continuously to identify weaknesses and strengths that support the processes of leadership/management. Nevertheless, there is a dearth of studies on the assessment of oral health in specialized care that may indicate which factors should be investigated. Therefore, this integrated literature review sought to explore the plethora of publications on the evaluation of SDCC in the LILACS and MEDLINE data bases in October 2013 to identify factors possibly related to the performance of such health services. Thus, 13 references were included in this review pointing to forms of organization and management of work processes related to the creation of healthcare networks (operation of regulation centers and setting up of health consortiums. They include the contextual characteristics of the places where SDCCs are located (population size, Family Health Strategy coverage, Municipal Human Development Index, governance, governing capacity were factors that influenced the SDCCs performance.

  11. Factors related to treatment refusal in Taiwanese cancer patients.

    Science.gov (United States)

    Chiang, Ting-Yu; Wang, Chao-Hui; Lin, Yu-Fen; Chou, Shu-Lan; Wang, Ching-Ting; Juang, Hsiao-Ting; Lin, Yung-Chang; Lin, Mei-Hsiang

    2015-01-01

    Incidence and mortality rates for cancer have increased dramatically in the recent 30 years in Taiwan. However, not all patients receive treatment. Treatment refusal might impair patient survival and life quality. In order to improve this situation, we proposed this study to evaluate factors that are related to refusal of treatment in cancer patients via a cancer case manager system. This study analysed data from a case management system during the period from 2010 to 2012 at a medical center in Northern Taiwan. We enrolled a total of 14,974 patients who were diagnosed with cancer. Using the PRECEDE Model as a framework, we conducted logistic regression analysis to identify independent variables that are significantly associated with refusal of therapy in cancer patients. A multivariate logistic regression model was also applied to estimate adjusted the odds ratios (ORs) with 95% confidence intervals (95%CI). A total of 253 patients (1.69%) refused treatment. The multivariate logistic regression result showed that the high risk factors for refusal of treatment in cancer patient included: concerns about adverse effects (prefuse treatment have poor survival. The present study provides evidence of factors that are related to refusal of therapy and might be helpful for further application and improvement of cancer care.

  12. Relation of Cardiometabolic Risk Factors between Parents and Children.

    Science.gov (United States)

    Halvorsen, Tanya; Moran, Antoinette; Jacobs, David R; Steffen, Lyn M; Sinaiko, Alan R; Zhou, Xia; Steinberger, Julia

    2015-11-01

    To explore the relations of parent-child cardiometabolic risk factors and assess the influence of adiposity on these associations. Associations of adiposity, blood pressure (BP), lipids, fasting insulin and glucose, and a risk factor cluster score (CS) were evaluated in a cross-sectional study of 179 parents and their children (6-18 years, N = 255). Insulin resistance was assessed by euglycemic clamp in parents and children aged 10 years or older. Metabolic syndrome in parents was defined by National Cholesterol Education Program's Adult Treatment Panel III criteria. CSs of the risk factors were created based on age-specific z-scores. Analyses included Pearson correlation and linear regression, adjusted for parent and child age, sex, race, and body mass index (BMI), accounting for within-family correlation. We found positive parent-child correlations for measures of adiposity (BMI, BMI percentile, waist, subcutaneous fat, and visceral fat; r = 0.22-0.34, all P ≤ .003), systolic BP (r = 0.20, P = .002), total cholesterol (r = 0.39, P parent-child correlations, except systolic BP, remained significant. Although adiposity is strongly correlated between parents and children, many cardiometabolic risk factors correlate independent of parent and child BMI. Adverse parental cardiometabolic profiles may identify at-risk children independent of the child's adiposity status. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Factors Relating to Self-Efficacy Among Psychiatric Nurses.

    Science.gov (United States)

    Yada, Hironori; Kobayashi, Mako; Odachi, Ryo; Yamane, Toshie

    This study aimed to clarify the factors related to self-efficacy experienced by psychiatric nurses. Analysis of qualitative descriptive data from a free self-description questionnaire administered to 16 psychiatric nurses working in psychiatric hospitals revealed 24 codes across the following 8 categories as factors that increase self-efficacy: A1. possibility of practical use in nursing, A2. nursing judgment, A3. improvement of psychiatric symptoms, A4. the patients presenting a positive attitude, A5. building a relationship of trust with the patients, A6. building a relationship of trust with other nurses, A7. work progressing according to plan and A8. team medical practice. Twenty-five codes across the following 10 categories were identified as factors that decrease self-efficacy: B1. lack of communication, B2. uncertainty in caregiving, B3. recurrence of psychiatric symptoms, B4. feeling overpowered by a patient, B5. sense of being too busy to work adequately, B6. difficulty in bringing about self-improvement, B7. sense of loss regarding one's role as a nurse, B8. lack of physical strength, B9. mechanical performance of nursing and B10. fluctuating view of nursing due to mistakes. These factors require intervention for psychiatric nurses' self-efficacy.

  14. The effects of lower than conventional doses of oral nadolol on relative beta 1/beta 2-adrenoceptor blockade.

    Science.gov (United States)

    Wheeldon, N M; McDevitt, D G; Lipworth, B J

    1994-08-01

    1. The aim of the present study was to evaluate the relative beta 1/beta 2 antagonist selectivity of the beta-adrenoceptor blocker nadolol, in lower than conventional clinical doses. 2. Eight normal volunteers received single oral doses of either placebo (PL), nadolol 5 mg (N5), 20 mg (N20) or 80 mg (N80) in a single-blind, randomised crossover design. beta 1-adrenoceptor antagonism was assessed by attenuation of exercise tachycardia, and beta 2-adrenoceptor blockade by effects on salbutamol-induced chronotropic, hypokalaemic and finger tremor responses. The relative percentage attenuation of beta 2 and beta 1-mediated responses was calculated and expressed as beta 2:beta 1 selectivity ratios. 3. Nadolol produced dose-related reductions in exercise tachycardia in keeping with increasing beta 1-adrenoceptor blockade; mean % reduction (95% CI) compared with placebo: N5 10.7 (6.6 to 14.8), N20 21.4 (17.3 to 25.4), N80 38.9 (34.8 to 42.9). However, even the lowest dose of nadolol (5 mg) produced almost complete blunting of beta 2-mediated effects and significantly increase exercise hyperkalaemia; peak exercise hyperkalaemia (mmol l-1) (means and 95% CI): PL 4.88 (4.68 to 5.07), N5 5.36 (5.17 to 5.55), N20 5.48 (5.28 to 5.67), N80 5.42 (5.22 to 5.61). beta 2:beta 1 selectivity ratios significantly increased as the dose of nadolol was reduced. 4. These data suggest that whereas in the clinical dose range nadolol behaves as a non-selective beta-adrenoceptor antagonist, as the dose is reduced this drug demonstrates an increasing degree of selectivity for the beta 2-adrenoceptor.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Analysis of factors related to arm weakness in patients with breast cancer-related lymphedema.

    Science.gov (United States)

    Lee, Daegu; Hwang, Ji Hye; Chu, Inho; Chang, Hyun Ju; Shim, Young Hun; Kim, Jung Hyun

    2015-08-01

    The aim of this study was to evaluate the ratio of significant weakness in the affected arm of breast cancer-related lymphedema patients to their unaffected side. Another purpose was to identify factors related to arm weakness and physical function in patients with breast cancer-related lymphedema. Consecutive patients (n = 80) attended a single evaluation session following their outpatient lymphedema clinic visit. Possible independent factors (i.e., lymphedema, pain, psychological, educational, and behavioral) were evaluated. Handgrip strength was used to assess upper extremity muscle strength and the disabilities of arm, shoulder, and hand (DASH) questionnaire was used to assess upper extremity physical function. Multivariate logistic regression was performed using factors that had significant differences between the handgrip weakness and non-weakness groups. Out of the 80 patients with breast cancer-related lymphedema, 29 patients (36.3 %) had significant weakness in the affected arm. Weakness of the arm with lymphedema was not related to lymphedema itself, but was related to the fear of using the affected limb (odds ratio = 1.76, 95 % confidence interval = 1.30-2.37). Fears of using the affected limb and depression significantly contributed to the variance in DASH scores. Appropriate physical and psychological interventions, including providing accurate information and reassurance of physical activity safety, are necessary to prevent arm weakness and physical dysfunction in patients with breast cancer-related lymphedema.

  16. Dose Relations between Goal Setting, Theory-Based Correlates of Goal Setting and Increases in Physical Activity during a Workplace Trial

    Science.gov (United States)

    Dishman, Rod K.; Vandenberg, Robert J.; Motl, Robert W.; Wilson, Mark G.; DeJoy, David M.

    2010-01-01

    The effectiveness of an intervention depends on its dose and on moderators of dose, which usually are not studied. The purpose of the study is to determine whether goal setting and theory-based moderators of goal setting had dose relations with increases in goal-related physical activity during a successful workplace intervention. A…

  17. Investigation of dose modifications related to dental cares in an ORL radiotherapy treatment

    International Nuclear Information System (INIS)

    De Conto, C.; Gschwind, R.; Makovicka, L.; De Conto, C.; Martin, E.

    2010-01-01

    The authors report the investigation of the influence of dental implants on the dose received during an ORL radiotherapy treatment in order to optimize both the dosimetric planning and the patient radioprotection. They report experimental measurements performed on a phantom representing a lower jaw in irradiation conventional conditions. Then, they report the Monte Carlo simulation of the dose distribution in the phantom using the BEAMnrc code designed for radiotherapy

  18. Factors related to tinnitus and hyperacusis handicap in older people.

    Science.gov (United States)

    Aazh, Hashir; Lammaing, Karen; Moore, Brian C J

    2017-09-01

    The aim was to assess factors related to tinnitus and hyperacusis handicap in older people. Retrospective cross-sectional. Data were gathered for 184 patients with an average age of 69 years. Tinnitus handicap as measured via the Tinnitus Handicap Inventory (THI) was significantly predicted by tinnitus annoyance as measured via the visual analogue scale (VAS) (regression coefficient, b = 2.9, p tinnitus on the patient's life as measured via the VAS (b = 3.9, p tinnitus annoyance significantly predicts tinnitus handicap, it is important to explore factors associated with annoyance that may be useful in designing appropriate rehabilitative interventions aimed at reducing tinnitus handicap in older people. Future studies should explore whether hyperacusis and insomnia in older people with tinnitus need to be managed in conjunction with treatment for depression.

  19. Relations of age and personality dimensions to cognitive ability factors.

    Science.gov (United States)

    Costa, P T; Fozard, J L; McCrae, R R; Bosśe, R

    1976-11-01

    The relation between three cognitive ability factors - Information Processing Ability (IPA), Manual Dexterity (MD), and Pattern Analysis Capability (PAC) - and three personality dimensions - Anxiety, Extraversion, and Openness to Experience - were examined in three age groups. Subjects were 969 male volunteers ranging in age from 25 to 82. Subjects high in anixety scored lower on all three cognitive factors; subjects open to experience scored higher on IPA and PAC; and introverted subjects scored higher on PAC. Most of these effects remained when the education and socio-economic status were held constant in covariance analyses. Older subjects performed less well than younger ones on MD and PAC, but not on IPA. While personality has some influence on cognitive performance, the declines with age in performance on some cognitive tasks are not mediated by personality.

  20. Nuclear factor erythroid 2-related factor 2 deletion impairs glucose tolerance and exacerbates hyperglycemia in type 1 diabetic mice.

    Science.gov (United States)

    Aleksunes, Lauren M; Reisman, Scott A; Yeager, Ronnie L; Goedken, Michael J; Klaassen, Curtis D

    2010-04-01

    The transcription factor nuclear factor erythroid 2-related factor 2 (Nrf2) induces a battery of cytoprotective genes after oxidative stress. Nrf2 aids in liver regeneration by altering insulin signaling; however, whether Nrf2 participates in hepatic glucose homeostasis is unknown. Compared with wild-type mice, mice lacking Nrf2 (Nrf2-null) have lower basal serum insulin and prolonged hyperglycemia in response to an intraperitoneal glucose challenge. In the present study, blood glucose, serum insulin, urine flow rate, and hepatic expression of glucose-related genes were quantified in male diabetic wild-type and Nrf2-null mice. Type 1 diabetes was induced with a single intraperitoneal dose (200 mg/kg) of streptozotocin (STZ). Histopathology and serum insulin levels confirmed depleted pancreatic beta-cells in STZ-treated mice of both genotypes. Five days after STZ, Nrf2-null mice had higher blood glucose levels than wild-type mice. Nine days after STZ, polyuria occurred in both genotypes with more urine output from Nrf2-null mice (11-fold) than wild-type mice (7-fold). Moreover, STZ-treated Nrf2-null mice had higher levels of serum beta-hydroxybutyrate, triglycerides, and fatty acids 10 days after STZ compared with wild-type mice. STZ reduced hepatic glycogen in both genotypes, with less observed in Nrf2-null mice. Increased urine output and blood glucose in STZ-treated Nrf2-null mice corresponded with enhanced gluconeogenesis (glucose-6-phosphatase and phosphoenolpyruvate carboxykinase)- and reduced glycolysis (pyruvate kinase)-related mRNA expression in their livers. Furthermore, the Nrf2 activator oltipraz lowered blood glucose in wild-type but not Nrf2-null mice administered STZ. Collectively, these data indicate that the absence of Nrf2 worsens hyperglycemia in type I diabetic mice and Nrf2 may represent a therapeutic target for reducing circulating glucose levels.

  1. Reduction in flatulent factors in mung bean using low dose - radiation

    International Nuclear Information System (INIS)

    Machaiah, J.P.; Pednekar, M.D.; Thomas, Paul

    1997-01-01

    Mung beans, γ-irradiated at the disinfestation dose of 0.25 to 0.75 kGy and germinated (0-6 days), contained significantly lower levels of flatulence causing digosaccharides compared to the control, thus enhancing their nutritional quality and acceptability. (author). 2 refs., 3 figs

  2. From concentration to dose: factors influencing airborne particulate matter deposition in humans and rats

    NARCIS (Netherlands)

    Winter-sorkina R de; Cassee FR; LBV; LBO

    2003-01-01

    Particulate matter (PM) consisting of solid particles and droplets is present in the ambient air. Particles with an aerodynamic diameter less than 10 micro m can be inhaled by humans. Knowledge of the tissue-specific internal dose of PM is a critical link between individual external exposure and

  3. Cultural Competence and Related Factors Among Taiwanese Nurses.

    Science.gov (United States)

    Lin, Chin-Nu; Mastel-Smith, Beth; Alfred, Danita; Lin, Yu-Hua

    2015-12-01

    Taiwan is a multicultural and multiethnic society with a growing number of immigrants who have diverse ethnic, racial, and cultural needs. Although this diversity highlights the pressing need for culturally competent healthcare providers, cultural competence is a concept that is little understood and implemented only sporadically in Taiwan. This study investigates the cultural competence of Taiwanese nurses and the related factors of influence. An online self-report survey was used to collect data from 221 Taiwanese nurses from December 2012 through January 2013. Data from the demographic questionnaire, the Nurses' Cultural Competence Scale, and the Perceived Nurses' Cultural Competence Rating were analyzed using descriptive statistics, Pearson correlation, independent sample t tests, and multiple regressions. The cultural competence of the participants was in the "low to moderate" range, with relatively higher mean scores for the subscales of cultural awareness and cultural sensitivity and relatively lower scores for the subscales of cultural knowledge and cultural skills. Participants generally perceived themselves as being "not culturally competent." Variables found to predict cultural competence included years of work experience, hours of continuing education related to cultural nursing care, and frequency of caring for clients from culturally and ethnically diverse backgrounds. Participating Taiwanese nurses rated their level of cultural competence as in the low-to-moderate range and self-perceived as being not culturally competent. These findings support the need to further expand and enhance cultural-competence-related continuing education and to address the topic of cultural care in the nursing curricula.

  4. [Factors related to the life space of daycare center users].

    Science.gov (United States)

    Kawamura, Koki; Kato, Chikako; Kondo, Izumi

    2018-01-01

    We examined the factors related to life space and changes in the care level after one year in daycare center users. The participants were 83 older adults (age, > 65 years; mean age, 79.5±6.8 years) with MMSE scores of ≥20, who could walk independently, who needed support (1-2) or care (1), and who underwent rehabilitation at a daycare center. The life space was evaluated by the Life Space Assessment (LSA). The subjects' basic information (i.e., age, medical history.) was collected, and their physical function (i.e., grip strength, timed up and go test [TUG]), mental function (i.e., vitality, fear of falls), and social function (i.e., friends, hobbies, public transportation) were assessed to investigate the factors associated with their LSA scores. In addition, a follow-up survey was conducted on the care level at approximately one year later. A multiple regression analysis indicated that TUG scores (β=-0.33), hobbies (β=0.30), friends (β=0.29), public transportation (β=0.26), and grip strength (β=0.24) were related to the life space. Next, the participants were divided into LSA-high and LSA-low groups, and changes in the care level (improvement, maintenance, deterioration) at approximately one year after the initial assessment were examined using a chi-squared test. A significant difference was observed in the distribution of the groups (p=0.03). Multiple factors were related to the life space. Moreover, it is possible that improvements in the level of care may be achieved by improving the life space.

  5. Treatment, material, care, and patient-related factors in contact lens-related dry eye.

    Science.gov (United States)

    Ramamoorthy, Padmapriya; Sinnott, Loraine T; Nichols, Jason J

    2008-08-01

    To examine the effect of general contact lens and material characteristics, care solutions, treatment, and patient-related factors on contact lens-related dry eye. The data were derived from the Contact Lens and Dry Eye Study, designed as a cross-sectional and nested case-control study including 360 subjects. In separate statistical models, logistic regression was used to examine general contact lens characteristics, specific hydrogel lens materials, care solutions, and patient-related factors associated with dry eye status (controlled for age, gender, and current treatments). Several factors were significantly associated with dry eye, including treatment factors such as a recent contact lens refitting (odds ratios [OR] = 5.75, 95% confidence intervals [CI] = 2.14 to 15.46) and use of artificial tears/rewetting drops (OR = 1.09, 95% CI = 1.02 to 1.16), in addition, currently worn materials including Food and Drug Administration (FDA) group II (OR = 2.98, 95% CI = 1.14 to 6.19) and IV (OR = 1.87, 95% CI = 1.08 to 3.24). Significant patient-related factors included decreased overall satisfaction (OR = 3.57, 95% CI = 2.08 to 5.88,), dry eye in the absence of contact lens wear (OR = 6.54, 95% CI = 2.57 to 16.62), reduced daily lens wear duration (OR = 1.16, 95% CI = 1.06 to 1.26), and reduced ability to wear lenses as long as desired (OR = 2.44, 95% CI = 1.30 to 4.54). Care solutions were not associated with contact lens-related dry eye. The strong association of common treatment factors with dry eye status in contact lens wearers suggests that these treatments are not entirely effective. The use of high water content materials was strongly related to dry eye in lens wearers, whereas care solutions were not. Contact lens-related dry eye was also associated with several patient-related factors such as greater ocular discomfort (without lenses), dissatisfaction, and inability to wear lenses for desired durations.

  6. Monte Carlo study of MOSFET dosimeter dose correction factors considering energy spectrum of radiation field in a steam generator channel head

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Koo; Choi, Sang Hyoun; Kim, Chan Hyeong [Hanyang Univ., Seoul (Korea, Republic of)

    2006-12-15

    In Korea, a real-time effective dose measurement system is in development. The system uses 32 high-sensitivity MOSFET dosimeters to measure radiation doses at various organ locations in an anthropomorphic physical phantom. The MOSFET dosimeters are, however, mainly made of silicon and shows some degree of energy and angular dependence especially for low energy photons. This study determines the correction factors to correct for these dependences of the MOSFET dosimeters for accurate measurement of radiation doses at organ locations in the phantom. For this, first, the dose correction factors of MOSFET dosimeters were determined for the energy spectrum in the steam generator channel of the Kori Nuclear Power Plant Unit no.1 by Monte Carlo simulations. Then, the results were compared with the dose correction factors from 0.662 MeV and 1.25 MeV mono-energetic photons. The difference of the dose correction factors were found very negligible ({<=}1.5%), which in general shows that the dose corrections factors determined from 0.662 MeV and 1.25 MeV can be in a steam general channel head of a nuclear power plant. The measured effective dose was generally found to decrease by {approx}7% when we apply the dose correction factors.

  7. Risk Estimates and Risk Factors Related to Psychiatric Inpatient Suicide

    DEFF Research Database (Denmark)

    Madsen, Trine; Erlangsen, Annette; Nordentoft, Merete

    2017-01-01

    trends, and socio-demographic and clinical risk factors of suicide in psychiatric inpatients. Psychiatric inpatients have a very high risk of suicide relative to the background population, but it remains challenging for clinicians to identify those patients that are most likely to die from suicide during......People with mental illness have an increased risk of suicide. The aim of this paper is to provide an overview of suicide risk estimates among psychiatric inpatients based on the body of evidence found in scientific peer-reviewed literature; primarily focusing on the relative risks, rates, time...... admission. Most studies are based on low power, thus compromising quality and generalisability. The few studies with sufficient statistical power mainly identified non-modifiable risk predictors such as male gender, diagnosis, or recent deliberate self-harm. Also, the predictive value of these predictors...

  8. Risk Estimates and Risk Factors Related to Psychiatric Inpatient Suicide

    DEFF Research Database (Denmark)

    Madsen, Trine; Erlangsen, Annette; Nordentoft, Merete

    2017-01-01

    People with mental illness have an increased risk of suicide. The aim of this paper is to provide an overview of suicide risk estimates among psychiatric inpatients based on the body of evidence found in scientific peer-reviewed literature; primarily focusing on the relative risks, rates, time...... trends, and socio-demographic and clinical risk factors of suicide in psychiatric inpatients. Psychiatric inpatients have a very high risk of suicide relative to the background population, but it remains challenging for clinicians to identify those patients that are most likely to die from suicide during...... is low. It would be of great benefit if future studies would be based on large samples while focusing on modifiable predictors over the course of an admission, such as hopelessness, depressive symptoms, and family/social situations. This would improve our chances of developing better risk assessment...

  9. Outcomes of visual acuity in carbon ion radiotherapy: Analysis of dose-volume histograms and prognostic factors

    International Nuclear Information System (INIS)

    Hasegawa, Azusa; Mizoe, Jun-etsu; Mizota, Atsushi; Tsujii, Hirohiko

    200